Materials for energy efficiency and thermal comfort in buildings
i © Woodhead Publishing Limited, 2010
Related titles: Sustainability of construction materials (ISBN 978-1-84569-349-7) Major concerns have been raised on the sustainability of construction activities, in particular the sustainability of construction materials. A great deal of research has been carried out to quantify the ecological and environmental impact caused during the life cycle of construction materials. This book is the first of its kind to compile all the information on the sustainability of construction materials together into one complete volume. Sustainability of construction materials presents current research from a leading team of international contributors and will be an invaluable resource for all those professions involved in infrastructure development, construction and design. Durability of composites for civil structural applications (ISBN 978-1-84569-035-9) This comprehensive book on the durability of FRP composites will make it easier for the practising civil engineer and designer to use such materials on a routine basis. It addresses the current lack – or inaccessibility – of data related to the durability of the materials which is proving to be one of the major challenges to the widespread acceptance and implementation of FRP composites in civil infrastructure. The book should help further the acceptance of composites for civil structural applications and will be essential reading for practising engineers, decision makers and students involved in architectural engineering, construction and materials, disaster reduction, environmental engineering, maritime structural technology, transportation engineering and urban planning. Mineral wool: production and properties (ISBN 978-1-84569-406-7) Mineral wool has a unique range of properties combining high thermal resistance with long-term stability. It is made from molten glass, stone or slag that is spun into a fibrelike structure which creates a combination of properties that no other insulation material can match. It has the ability to save energy, minimise pollution, combat noise, reduce the risk of fire and protect life and property in the event of fire. Mineral wool: production and properties is suitable for engineers, researchers and for graduate and postgraduate students who want to broaden their knowledge of experimental methods in this field. Details of these and other Woodhead Publishing materials books can be obtained by: ∑ visiting our web site at www.woodheadpublishing.com ∑ contacting Customer Services (e-mail:
[email protected]; fax: +44 (0) 1223 893694; tel.: +44 (0) 1223 891358 ext. 130; address: Woodhead Publishing Limited, Abington Hall, Granta Park, Great Abington, Cambridge CB21 6AH, UK) If you would like to receive information on forthcoming titles, please send your address details to: Francis Dodds (address, tel. and fax as above; e-mail: francis.
[email protected]). Please confirm which subject areas you are interested in.
ii © Woodhead Publishing Limited, 2010
Woodhead Publishing Series in Energy: Number 14
Materials for energy efficiency and thermal comfort in buildings Edited by Matthew R. Hall
CRC Press Boca Raton Boston New York Washington, DC
Woodhead
publishing limited
Oxford Cambridge New Delhi iii
© Woodhead Publishing Limited, 2010
Published by Woodhead Publishing Limited, Abington Hall, Granta Park, Great Abington, Cambridge CB21 6AH, UK www.woodheadpublishing.com Woodhead Publishing India Private Limited, G-2, Vardaan House, 7/28 Ansari Road, Daryaganj, New Delhi – 110002, India www.woodheadpublishingindia.com Published in North America by CRC Press LLC, 6000 Broken Sound Parkway, NW, Suite 300, Boca Raton, FL 33487, USA First published 2010, Woodhead Publishing Limited and CRC Press LLC © Woodhead Publishing Limited, 2010 The authors have asserted their moral rights. This book contains information obtained from authentic and highly regarded sources. Reprinted material is quoted with permission, and sources are indicated. Reasonable efforts have been made to publish reliable data and information, but the authors and the publishers cannot assume responsibility for the validity of all materials. Neither the authors nor the publishers, nor anyone else associated with this publication, shall be liable for any loss, damage or liability directly or indirectly caused or alleged to be caused by this book. Neither this book nor any part may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, microfilming and recording, or by any information storage or retrieval system, without permission in writing from Woodhead Publishing Limited. The consent of Woodhead Publishing Limited does not extend to copying for general distribution, for promotion, for creating new works, or for resale. Specific permission must be obtained in writing from Woodhead Publishing Limited for such copying. Trademark notice: Product or corporate names may be trademarks or registered trademarks, and are used only for identification and explanation, without intent to infringe. British Library Cataloguing in Publication Data A catalogue record for this book is available from the British Library. Library of Congress Cataloging in Publication Data A catalog record for this book is available from the Library of Congress. Woodhead Publishing ISBN 978-1-84569-526-2 (book) Woodhead Publishing ISBN 978-1-84569-927-7 (e-book) CRC Press ISBN 978-1-4398-2970-7 CRC Press order number N10167 The publishers’ policy is to use permanent paper from mills that operate a sustainable forestry policy, and which has been manufactured from pulp which is processed using acid-free and elemental chlorine-free practices. Furthermore, the publishers ensure that the text paper and cover board used have met acceptable environmental accreditation standards. Typeset by Replika Press Pvt Ltd, India Printed by TJ International Limited, Padstow, Cornwall, UK
iv © Woodhead Publishing Limited, 2010
Contents
Contributor contact details
xv
Woodhead Publishing Series in Energy
xix
Preface
xxi
Part I Fundamental issues and building physics: understanding energy efficiency and thermal comfort in the built environment 1
Heat and mass transport processes in building materials
M. R. Hall, University of Nottingham, UK and D. Allinson, Loughborough University, UK
1.1 1.2 1.3 1.4 1.5 1.6 1.7
Introduction Heat transfer: the transport of energy Mass transfer: the transport of matter Summary Sources of further information and advice References Appendix: Nomenclature
3 7 26 46 47 48 50
2
Hygrothermal behaviour and simulation in buildings
54
H. M. Künzel, Fraunhofer Institute for Building Physics IBP, Germany and A. Karagiozis, Oak Ridge National Laboratory, USA
2.1 2.2 2.3
Introduction Hygrothermal loads Modelling simultaneous heat and moisture transfer processes Input data for hygrothermal calculations Hygrothermal calculation results Model validation and practical applications
2.4 2.5 2.6
3
54 55 57 59 63 65 v
© Woodhead Publishing Limited, 2010
vi
Contents
2.7 2.8 2.9
Limitations of current hygrothermal models Conclusions and future trends References
73 73 75
3
Ventilation, air quality and airtightness in buildings
77
D. W. Etheridge, University of Nottingham, UK
3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9
Introduction Ventilation systems Physical mechanisms Feasibility of natural ventilation Natural ventilation design Issues concerning materials Future trends Sources of further information and advice References and further reading
4
Heat energy storage and cooling in buildings
S. Wu, University of Nottingham, UK
4.1 4.2 4.3 4.4 4.5
101 102 106 118
4.6 4.7 4.8
Introduction Psychrometrics Fundamentals of thermal energy storage Materials for thermal energy storage Thermal storage applications for building heating and cooling Sources of further information and advice References Appendix: Nomenclature
5
Thermal comfort in buildings
127
K. Parsons, Loughborough University, UK
5.1 5.2 5.3 5.4 5.5 5.6 5.7
Introduction Thermal comfort Measurement of thermal comfort The thermal index: an assessment technique Thermal comfort indices International Standards and thermal comfort Behavioural thermoregulation, thermal comfort and the adaptive model Equivalent clothing index (IEQUIV) Equivalent clothing index, the comfort temperature range and temperature limits in offices Sustainable thermal comfort References
5.8 5.9 5.10 5.11
© Woodhead Publishing Limited, 2010
77 77 81 86 90 92 97 98 99 101
122 125 125 126
127 127 129 132 132 137 141 142 144 144 146
Contents
6
Environmental health and safety in buildings
P. Brimblecombe, University of East Anglia, UK
6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8
Introduction Safety issues in occupied spaces Combustion, fire and combustible materials Infiltration of outdoor pollutants Indoor emissions and outgassing Occupant activity Transformations within the interior Particles in buildings that impact on environmental health and safety Materials and toxicity Advanced material requirements Future trends References
6.9 6.10 6.11 6.12
vii
148 148 150 151 155 157 161 163 164 165 166 167 168
Part II Materials and sustainable technologies: improving energy efficiency and thermal comfort in the built environment 7
Life cycle assessment and environmental profiling of building materials
K. Steele, Arup: Façades and Materials, UK
7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 7.9
Materials sustainability A life cycle approach to selecting building materials A brief history of life cycle assessment (LCA) Environmental labelling Life cycle assessment (LCA) of building materials Life cycle assessment (LCA) standardisation UK context Other issues References
175 176 177 178 179 182 187 189 191
8
Inorganic mineral materials for insulation in buildings
193
R. Gellert, FIW München, Germany
8.1 8.2 8.3 8.4 8.5 8.6 8.7
Introduction Regulatory requirements Building-related properties Ecological and health aspects Individual product profiles Summary References
© Woodhead Publishing Limited, 2010
175
193 197 201 207 211 227 228
viii
Contents
9
Natural fibre and fibre composite materials for insulation in buildings
R. Gellert, FIW München, Germany
9.1 9.2 9.3 9.4 9.5 9.6 9.7 9.8
Introduction Regulatory requirements Building-related properties Ecological and health aspects Individual product profiles Reference buildings Summary References
229 231 235 237 240 249 255 255
10
Polymeric foam materials for insulation in buildings
257
D. Feldman, Concordia University, Canada
10.1 10.2 10.3 10.4 10.5 10.6 10.7 10.8
Introduction Foams classification, materials and foaming mechanism Processing technologies Thermoplastic and thermosetting foams Future trends Sources of further information and advice References Appendix: Abbreviations
257 258 262 265 269 269 269 272 274
11
Thermal insulation materials for building equipment
M. Zeitler, FIW München, Germany
11.1 11.2 11.3 11.4 11.5 11.6 11.7 11.8
Introduction Insulation materials Form pieces and form parts Support and spacer ring constructions Vapour retarder materials Claddings Insulation system Heat loss of the operational installation in the technical building equipment References
11.9 12
Reflective materials and radiant barriers for insulation in buildings
D. W. Yarbrough, R&D Services Inc., USA
12.1 12.2 12.3
Background and definitions Applications and assemblies Basis for thermal performance
© Woodhead Publishing Limited, 2010
229
274 275 296 297 298 298 298 301 303 305 305 307 309
Contents
12.4 12.5 12.6 12.7
ix
Measurement of thermal performance Codes and standards Sources of further information and advice References
313 315 316 318 319
13
Aerogel materials for insulation in buildings
C.-H. Yu, Q.J. Fu and S. C. E. Tsang, University of Oxford, UK
13.1 13.2 13.3 13.4 13.5 13.6 13.7 13.8
Introduction Processing material and properties Aerogel formation Physical properties of aerogels Applications of aerogels Future trends Conclusions References
319 321 325 332 336 336 339 339
14
Hygrothermal materials for heat and moisture control in buildings
345
M. R. Hall, University of Nottingham, UK
14.1 14.2 14.3 14.4 14.5 14.6 14.7 14.8 14.9
Introduction Characterization of hygrothermal functional properties Material classes Applications in buildings and occupied spaces Future trends Source of further information and advice Acknowledgements References Appendix: Nomenclature
345 349 351 358 360 361 361 362 363
15
Desiccant materials for moisture control in buildings
365
B. Warwicker, UK
15.1 15.2 15.3 15.4 15.5 15.6 15.7 15.8
Introduction Desiccant cycle Desiccant applications Health and comfort Air quality Natural and commercial desiccants: typical materials Practical applications of commercial desiccants Practical applications of natural desiccants for modifying building humidity 15.9 Bibliography 15.10 Appendix: Energy efficiency ratio (EER) and coefficient of performance (COP) © Woodhead Publishing Limited, 2010
365 366 367 367 369 370 373 378 382 382
x
Contents
16
Phase change materials for energy storage and thermal comfort in buildings
M. M. Farid and A. Sherrif, University of Auckland, New Zealand
16.1 16.2 16.3
Introduction Background Selection of phase change materials (PCM) and fabrication of PCM-gypsum wallboards (PCMGW) Full-scale testing facilities Benefits of applying thermal energy storage Computer simulation Conclusions References
16.4 16.5 16.6 16.7 16.8 17
Porous materials for direct and indirect evaporative cooling in buildings
X. Zhao, De Montfort University, UK
17.1 17.2
Introduction Assessing the capacities of evaporative cooling systems and the associated requirements in materials Comparative analyses of potential materials for evaporative cooling Potential applications of porous materials in buildings Conclusions References Appendix: Nomenclature
17.3 17.4 17.5 17.6 17.7 18
Prefabricated building units and modern methods of construction (MMC)
M. Mapston, MMConsult and one42morrow, UK and C. Westbrook, Mtech Consult Ltd, UK
18.1 18.2 18.3 18.4 18.5 18.6
Materials led building design Offsite construction Standardisation in construction Types of offsite construction Comfort factors in lightweight buildings Design led materials for addressing lightweight performance issues 18.7 Delivering sustainable comfort: a question of balance 18.8 Thin solutions (insulation and mass) 18.9 Thermal mass in offsite potential 18.10 Phase change materials (PCMs) 18.11 Advancements in phase change materials for buildings
© Woodhead Publishing Limited, 2010
384 384 385 386 389 390 394 396 397 399 399 404 409 417 422 423 426 427
427 428 431 431 440 441 442 444 445 445 446
Contents
18.12 New membrane developments 18.13 Composite design 18.14 References
xi
448 449 451
19
Roofing materials for thermal performance and environmental integration of buildings
J. Jones, Virginia Tech, USA
19.1 19.2 19.3 19.4 19.5 19.6 19.7 19.8 19.9 19.10
A question of design Roof construction Thermal performance of roofing materials Vegetated roofing systems Solar integrated roofing systems Natural ventilation Rainwater harvesting The role of roofs in building rating systems Conclusions References
455 458 464 466 474 476 478 480 481 482
20
Assessing and benchmarking the performance of advanced building façades
484
J. A. Clarke and C. M. Johnstone, University of Strathclyde, UK
20.1 20.2 20.3 20.4 20.5 20.6 20.7 20.8
Advanced façades Façade component options Performance models and model parameter measurement Integrated performance rating Application in practice Benchmarking façade performance Sources of further information and advice References
455
484 485 486 494 495 499 501 502
Part III Application of advanced building materials and design: improving energy efficiency and thermal comfort in the built environment 21
Advanced building materials and eco-building design
B. Watts, Max Fordham LLP, UK
21.1 21.2 21.3 21.4 21.5 21.6
Introduction Issues in eco-building design Challenges of sustainable development for a designer The eco-building design process Heelis: brief case history Future trends
© Woodhead Publishing Limited, 2010
505 505 506 513 520 523 526
xii
Contents
21.7 21.8
Sources of further information and advice References
531 531
22
Materials for energy efficiency and thermal comfort in domestic buildings
533
A. Peacock, Heriot Watt University, UK
22.1 22.2 22.3 22.4 22.5 22.6 22.7 22.8 22.9 22.10 22.11 22.12
Introduction EU domestic housing stock UK domestic housing Building fabric heat loss and CO2 emissions Architectural vernacular Intervention strategies Internal wall insulation External wall insulation Carbon payback time Summary Sources of further information and advice References
533 534 534 537 540 541 543 545 546 558 559 559
23
Materials for energy efficiency and thermal comfort in commercial buildings
562
D. H. C. Chow, University of Nottingham Ningbo, China
23.1 23.2 23.3 23.4
Introduction Energy efficiency and thermal comfort in offices Energy efficiency and thermal comfort in retail spaces Energy efficiency and thermal comfort in factories and warehouses 23.5 Embodied energy 23.6 Material choice 23.7 Modelling and monitoring thermal performance and comfort 23.8 Future trends in design and refurbishment 23.9 Sources of further information and advice 23.10 References 24
Materials for energy efficiency and thermal comfort in high performance buildings
P. C. J. Davda, G. Sex and J. Broomfield, The Austin Company of UK Ltd, UK
24.1 24.2 24.3 24.4
Introduction User considerations External considerations Internal considerations
© Woodhead Publishing Limited, 2010
562 563 570 574 577 578 580 583 586 586 589
589 591 595 598
Contents
24.5 24.6 24.7 24.8 24.9
Process areas People areas Environmental design and computer modelling Environmental and energy considerations Building Research Establishment Environmental Assessment Method (BREEAM®) 24.10 Future trends 24.11 Sources of further information and advice 24.12 Notes and references
xiii
598 612 612 613 622 623 626 626
25
Materials for energy efficiency and thermal comfort in new buildings
L. Shao, De Montfort University, UK
25.1 25.2 25.3 25.4 25.5 25.6 25.7 25.8 25.9
Introduction Challenges facing the new build construction sector The role, shape and trend of legislation Thermal mass Phase change materials (PCMs) Vegetation and reflective materials Future trends Sources of further information and advice References
631 632 634 637 640 643 645 647 647
26
Materials for energy efficiency and thermal comfort in the refurbishment of existing buildings
649
M. Gillott and C. Spataru, University of Nottingham, UK
26.1 26.2 26.3 26.4 26.5 26.6 26.7
Introduction Change of use in buildings Approaches to low carbon retrofit systems/technologies Post-occupancy evaluation (POE) Sources of further information and advice Acknowledgements References and further reading
649 656 661 668 677 679 679
27
Application of design and passive technologies for thermal comfort in buildings in hot and tropical climates
681
M. B. Gadi, University of Nottingham, UK
27.1 27.2
Thermal comfort in different climates Climate impact on urban pattern and building form and fabric Climate impact on building fabric
27.3
© Woodhead Publishing Limited, 2010
631
681 685 688
xiv
Contents
27.4
27.6 27.7 27.8 27.9
Approaches and lessons learned from traditional hotclimate architecture Applications of design and passive technologies in modern buildings Thermal performance of passive solar systems Conclusions Sources of further information and advice References and further reading
Index
27.5
689 696 699 704 705 706 709
© Woodhead Publishing Limited, 2010
Contributor contact details
(* = main contact)
Chapters 1 and 14 Dr Matthew R. Hall* Department of the Built Environment Faculty of Engineering University of Nottingham University Park Nottingham NG7 2RD UK E-mail:
[email protected]
Dr David Allinson Department of Civil & Building Engineering Loughborough University Leicestershire LE11 3TU UK
Chapter 2 Dr Hartwig M. Künzel* Fraunhofer Institute for Building Physics IBP Fraunhofer Str. 10 83636 Valley Germany E-mail:
[email protected]
Dr Achilles Karagiozis Oak Ridge National Laboratory, BTC PO Box 2008, Building 3147 Oak Ridge, TN 37831 USA
Chapter 3 Dr David W. Etheridge Department of the Built Environment Faculty of Engineering University of Nottingham University Park Nottingham NG7 2RD UK E-mail: david.etheridge@nottingham. ac.uk
Chapter 4 Dr Shenyi Wu Department of the Built Environment Faculty of Engineering University of Nottingham University Park Nottingham NG7 2RD UK E-mail:
[email protected]
xv © Woodhead Publishing Limited, 2010
xvi
Contributor contact details
Chapter 5
Chapter 10
Professor Ken Parsons Department of Human Sciences Loughborough University Loughborough LE11 3TU UK
Professor Dorel Feldman Department of Building, Civil and Environmental Engineering Concordia University 1455 De Maisonneuve Blvd.W Montreal Quebec Canada H3G 1M8
E-mail:
[email protected]
Chapter 6
E-mail:
[email protected]
Professor Peter Brimblecombe University of East Anglia Norwich NR4 7TJ UK E-mail:
[email protected]
Chapter 7 Dr Kristian Steele Arup: Façades and Materials 13 Fitzroy Street London W1T 4BQ UK E-mail:
[email protected]
Chapters 8 and 9 Dr Roland Gellert Forschungsinstitut für Wärmeschutz e. V. München (FIW München) Lochhamer Schlag 4 D-82166 Gräfelfing Germany
Chapter 11 Dr-Ing. Martin Zeitler Head of Department Industrial Insulation Forschungsinstitut für Wärmeschutz e. V. München (FIW München) Lochhamer Schlag 4 82166 Gräfelfing Germany E-mail:
[email protected]
Chapter 12 David W. Yarbrough R&D Services, Inc. 102 mill Drive Cookeville, TN 38501 USA E-mail:
[email protected]
E-mail:
[email protected]
© Woodhead Publishing Limited, 2010
Contributor contact details
Chapter 13
Chapter 18
Dr Chih-Hao Yu, Dr Qijia J. Fu and Professor S. C. Edman Tsang* Inorganic Chemistry Laboratory University of Oxford Oxford UK
Mike Mapston* MMConsult and one42morrow
E-mail:
[email protected]
Chapter 15 Professor Brian Warwicker The Mill Station Road Ardleign Co7 7RS UK E-mail:
[email protected]
Chapter 16 Mohammed M. Farid* and Adam Sherrif Department of Chemical and Materials Engineering School of Engineering University of Auckland Auckland New Zealand E-mail:
[email protected]
Chapter 17 Professor Xudong Zhao Institute of Energy and Sustainable Development De Montfort University The Gateway Leicester LE1 9BH UK
xvii
E-mail:
[email protected]
Charles Westbrook Mtech Consult Ltd Maple House Sitka Drive Shrewsbury Business Park Shrewsbury SY2 6LG UK E-mail:
[email protected]
Chapter 19 James Jones College of Architecture and Urban Studies Virginia Tech Blacksburg, VA 24061 USA E-mail:
[email protected]
Chapter 20 Professor Joe Clarke* and Cameron Johnstone Energy Systems Research Unit (ESRU) University of Strathclyde James Weir Building 75 Montrose Street Glasgow G1 1XJ UK E-mail:
[email protected]
E-mail:
[email protected]
© Woodhead Publishing Limited, 2010
xviii
Contributor contact details
Chapter 21
Chapter 25
Bill Watts Max Fordham LLP 42–3 Gloucester Crescent London NW1 7PE UK
Professor L. Shao Institute of Energy & Sustainable Development De Montfort University The Gateway Leicester LE1 9BH UK
E-mail:
[email protected]
E-mail:
[email protected]
Chapter 22 Dr Andrew Peacock Heriot Watt University The Energy Academy Riccarton Edinburgh EH15 2BA UK E-mail:
[email protected]
Chapter 23 Dr David H. C. Chow University of Nottingham Ningbo 199 Taikang East Road Ningbo, 315100 China E-mail:
[email protected]
Chapter 24 Prakash C. J. Davda*, Graham Sex and John Broomfield The Austin Company of UK Ltd Cardinal Point Park Road Rickmansworth Herts WD3 1RE UK
Chapter 26 Dr Mark Gillott* and Dr Catalina Spataru Department of the Built Environment Faculty of Engineering University of Nottingham University Park Nottingham NG7 2RD UK E-mail:
[email protected]
Chapter 27 Mohamed B. Gadi Department of the Built Environment Faculty of Engineering University of Nottingham University Park Nottingham NG7 2RD UK E-mail: mohamed.gadi@nottingham. ac.uk
E-mail:
[email protected]
© Woodhead Publishing Limited, 2010
Woodhead Publishing Series in Energy
1 Generating power at high efficiency: Combined cycle technology for sustainable energy production Eric Jeffs 2 Advanced separation techniques for nuclear fuel reprocessing and radioactive waste treatment Edited by Kenneth L. Nash and Gregg J. Lumetta 3 Bioalcohol production: Biochemical conversion of lignocellulosic biomass Edited by K.W. Waldron 4 Understanding and mitigating ageing in nuclear power plants: Materials and operational aspects of plant life management (PLiM) Edited by Philip G. Tipping 5 Advanced power plant materials, design and technology Edited by Dermot Roddy 6 Stand-alone and hybrid wind energy systems: Technology, energy storage and applications Edited by J.K. Kaldellis 7 Biodiesel science and technology: From soil to oil Jan C.J. Bart, Natale Palmeri and. Stefano Cavallaro 8 Developments and innovation in carbon dioxide (CO2) capture and storage technology Volume 1: Carbon dioxide (CO2) capture, transport and industrial applications Edited by M. Mercedes Maroto-Valer 9 Geologic repository systems for safe disposal of spent nuclear fuels and radioactive waste Edited by Joonhong Ahn and Michael J. Apted xix © Woodhead Publishing Limited, 2010
xx
Woodhead Publishing Series in Energy
10 Wind energy systems: Optimising design and construction for safe and reliable operation Edited by John D. Sørensen and Jens N. Sørensen 11 Solid oxide fuel cell technology: Principles, performance and operations Kevin Huang and John Bannister Goodenough 12 Handbook of advanced radioactive waste conditioning technologies Edited by Michael I. Ojovan 13 Nuclear reactor safety systems Edited by Dan Gabriel Cacuci 14 Materials for energy efficiency and thermal comfort in buildings Edited by Matthew R. Hall 15 Handbook of biofuels production: Processes and technology Edited by Rafael Luque, Juan Campelo and James Clark 16 Developments and innovation in carbon dioxide (CO2) capture and storage technology Volume 2: Carbon dioxide (CO2) storage and utilisation Edited by M. Mercedes Maroto-Valer 17 Oxy-fuel combustion for fossil-fuel power plants: Developments and applications for advanced CO2 capture Edited by Ligang Zheng
© Woodhead Publishing Limited, 2010
Preface
The creation of this book was stimulated by the vibrant international research activity coupling energy and buildings, along with the future driving potentials and demands in these fields that will no doubt ensue. The behaviour of our buildings, both in terms of the energy they consume and the thermal comfort they provide, can be described as a function of the materials from which they are made using the underpinning principles of building physics. In terms of the outdoor environment in which these buildings are placed, we face many challenges not least of which include the predictions for significant climatic changes and greater frequency of extreme weather events. We also face future shortages of energy and clean water supply, and an expanding (and ageing) population with ever-increasing demands for the right to a comfortable, healthy living environment. It is therefore vital that all those who can contribute to tackling these issues should have access to a comprehensive summary of the current knowledge that the many experts who have contributed to this book possess. Coupled with this is the intention to help identify gaps in the current levels of understanding, and to inspire further work where it is most needed along with a broader awareness and appreciation for the wealth of inter-disciplinary fields that can make many valid contributions to one another. There is a strong need to reduce our dependence on mechanical systems for controlling the indoor environment, especially against a background of forecasted climatic changes where cooling loads will increase whilst at the same time energy companies are less able to meet end user demands. Of course, it is vital that the exploration of better ways of meeting our energy demands (e.g. wind, tidal, geothermal, and solar technologies, etc.) be allowed to continue. However, ultimately the goal must be to achieve drastic demand-side reductions in energy, when our built environment currently accounts for around 50% of all carbon-related emissions contributing to global warming. We also have an expanding population whose average age is increasing, and who have higher expectations of health and comfort from their living environments. Any solutions to cut energy consumption will not be acceptable if they involve a backwards step in the quality of xxi © Woodhead Publishing Limited, 2010
xxii
Preface
life; rather they should coincide with significant advancements. Materials and allied technologies play a vital role in tackling some of the key issues relating to operational energy efficiency and thermal comfort in buildings using measures such as: ∑
reduction in fabric heat losses by increasing thermal insulation and eliminating cold bridging ∑ reduction in heat losses from air infiltration through improved air tightness ∑ reduction in indoor cooling loads by optimised air temperature and humidity buffering of the indoor environment and controlling solar gains. The structure and approach of this book is to provide an integrated and comprehensive package with parts designed to support and complement each other. The first part reviews the fundamental scientific and engineering principles associated with the various aspects of building physics that relate to materials and energy efficiency. The second part focuses entirely on both conventional and advanced materials, plus material technologies whose principle applications are to improve energy efficiency and thermal comfort in buildings and other occupied spaces. The final part covers the application of advanced building materials and design across a comprehensive range of building types and classifications. The reader can, for example, read about a particular material and/or technology in one part, whilst cross-referencing against the fundamentals that underpin its physical properties and the reasons for its behaviour, e.g. aerogel insulation materials and heat transfer in porous materials. Similarly, the reader can also read about best practice applications or a particular case study on a type of building, and cross refer this against detailed explanations of the specific materials and technologies that are employed for that application. Naturally, each chapter can also be used in isolation as a stand-alone contribution in its particular field. Part I: ‘Fundamental issues and building physics’ begins with a large, detailed chapter by Hall and Allison covering all key aspects of fundamental heat and mass (water) transport processes in building fabrics with particular emphasis on porous materials. This is then supported by a detailed, technical chapter by Künzel and Karagiozis on hygrothermal behaviour in buildings which deals with the coupled, inter-dependent nature of heat and moisture both in terms of storage and transport within materials. The mechanisms and systems of ventilation are explained in the next chapter (by Etheridge) along with issues relating to air quality and air tightness in buildings, along with the principles and design of natural ventilation. The fundamentals of thermal storage are addressed in Chapter 4 by Wu, including the principles of psychrometrics and sensible, latent and chemical storage, along with
© Woodhead Publishing Limited, 2010
Preface
xxiii
discussion of heat storage materials and the principles of cooling. In Chapter 5, Parsons explains the principles behind the measurement and quantification of thermal comfort, including adaptive comfort responses and thermal pleasure. Finally in this part, Brimblecombe explains in detail the principles of indoor air quality and the chemistry behind indoor pollutants from off-gassing, particulates, occupant behaviour and outdoor infiltration along with environmental health and safety aspects, including indoor fire and combustion risks/hazards and toxicity. It is widely recognised that the operational energy consumption of most building types currently outweighs their embodied energy by some margin. However, as we make dramatic increases in energy efficiency the embodied energy of the materials and components that we use will become proportionally larger and may account for a large proportion of the energy associated with buildings in the future. Along with this point is the fact that, in general terms, it is important to understand and consider the origins and manufacturing processes of the materials, as well as the energy that is required to manufacture them. For these reasons, Part II: ‘Materials and sustainable technologies’ begins with a chapter by steele that explains the principles of life cycle analysis and the approach of environmental profiling of building materials including summaries of the various energy-consuming processes upon which we rely and the environmental impacts that they can have. The following two chapters, both by Gellert, each consider insulation materials for use in buildings. The first discusses the composition, types and physical properties of various organic and inorganic mineral-based materials, whilst the second compares and explains the various types of natural fibre and fibre composite insulation materials and their performance. In Chapter 10, Feldman gives a detailed explanation of the chemical composition, manufacture and physical properties of polymeric foam insulation materials with descriptions of performance evaluation and new innovations. The following chapter by Zeitler covers thermal insulation for pipes and other building equipment and discusses the range of appropriate material types, supply forms and installations, comparison of material properties and details of regulatory performance assessment. The next topic to be covered, by Yarbrough in Chapter 12, is that of reflective materials and radiant barriers for insulation in buildings, which includes detailed coverage of the basis and approach for thermal performance assessment, regulatory codes and standards, and discussion of relevant applications and assemblies. Aerogel materials for insulation in buildings are covered in Chapter 13 by Yu, Fu and Tsang, which gives a detailed account of the processing and formation of aerogels, an explanation and discussion of their physical (including thermal) properties, and a summary of applications and future material developments. The application of hygrothermal materials for temperature and humidity control in buildings is discussed in Chapter 14 by Hall, including details of
© Woodhead Publishing Limited, 2010
xxiv
Preface
characterisation and testing of material functional properties and detailed descriptions of the various material classes and their physical properties. Chapter 15 by Warwicker follows on from this topic providing a detailed evaluation of dessicant materials, including desiccant cycles, materials class and properties, and explanations of their application for cooling and for humidity control in buildings. Phase change materials and their applications for thermal energy storage and thermal comfort in buildings are covered in Chapter 16 by Farid and Sherrif, along with case study evaluations and numerical model predictive studies. Next is a technical chapter by Zhao covering the use of porous materials for direct and indirect evaporative cooling systems and technologies in buildings with particular emphasis on novel façade technologies as well as explanations of the principles of evaporative cooling that are employed. To meet the modern demand for rapid assembly and low tolerances a resurgence of interest in pre-fabricated techniques has evolved into Modern Methods of Construction (MMC). A thorough overview of this topic is provided in Chapter 18 by Mapston and Westbrook evaluating new and emerging techniques and components and their role in improving energy efficiency and thermal comfort. Roofing materials and roof design is discussed in Chapter 19 by Jones from the perspective of improving the environmental performance and energy efficiency of buildings, whilst also evaluating material selection and thermal performance, green roofs and renewables integration. The final chapter in Part II, by Clarke and Johnstone, provides an excellent discussion on approaches to the design and environmental performance benchmarking of building fabrics by using advanced building façades as an example, and making use of relevant case studies. Part III: ‘Application of advanced building materials and design’ begins with an intriguing and insightful overview by Watts of the major issues in balancing comfort and health with sustainability in the eco-design of buildings. The next two chapters, by Peacock and Chow, respectively, both address materials and design applications for addressing energy efficiency and thermal comfort, firstly in domestic buildings and then in commercial buildings including offices, retail spaces and warehouses. Chapter 24 by Davda, Sex and Broomfield covers in detail specific issues in balancing energy efficiency with the requirements of high performance and specialist buildings, along with strategies and approaches for achieving this in laboratories and R&D facilities, medical research facilities, as well as clean rooms and high tech industry and assembly facilities. Chapter 25 by Shao provides an informative discussion of best practice approaches and considerations in relation to energy efficiency and thermal comfort design for new buildings, since it is vital that we make significant improvements in both affordable as well as state-of-the-art housing, for which there is great and increasing demand. Of course there are many additional challenges brought about by
© Woodhead Publishing Limited, 2010
Preface
xxv
the slow rate of renewal in our global building stock and the need to find acceptable retrofit solutions to reducing energy consumption whilst improving thermal comfort. Chapter 26 by Gillott and Spataru addresses the many issues associated with existing buildings and presents detailed discussion as to how energy efficiency and thermal comfort can be enhanced in line with modern best practice standards using materials and allied technologies for building retrofit. Finally, due to the wide variety in climatic regions across the globe, the last chapter, by Gadi, addresses how material selection and its incorporation within building design can be used to work with, rather than against, the ambient conditions found in different climatic zones in order to provide both energy efficiency and thermal comfort. It is hoped that this book will give great pleasure to many readers around the world and will prove to be a useful and informative resource for learning and instruction to students within the field. In addition, it is intended that this book will also act as a comprehensive and useful point of reference for researchers, academics, architects and engineers, and the industry, to maintain an awareness of the current state of knowledge and understanding, to give ideas and inspiration for new work in need of attention, and to develop a mutual appreciation for the many disciplines that can work together in the name of progress. Dr Matthew R. Hall University of Nottingham
© Woodhead Publishing Limited, 2010
Thispublicationwassponsoredby Thi bli ti db TheAustinCompanyofUKLimited Establishedin1938,Austinishometoacomprehensivesetofconsulting, design,engineering,managementandconstructionservices. Austinservicesareusedindividually,incombination,orasacomplete packageoncomplexandhighspecificationconstructionprojects,for creatingorupgradingindustrial,commercialandpublicbuildings. OurinͲhousetechnical,designandengineeringteamshavetheknowledge andexperiencerequiredtoundertakeprojectsfromconcepttocompletion. WorkthroughouttheUKandinEuropeisundertakenfromourofficesin NorthLondonandtheNorthWestofEngland.Internationalprojectscanbe handledthroughanetworkofcompanyandassociatedoffices. FacilitiesdesignedandconstructedbyAustingreatlyenhancecorporate future. AustinareleadingServiceProvidersforNewandRefurbishedFacility Austin are leading Service Providers for New and Refurbished Facility projects.
www.austin.co.uk–
[email protected]
Architecture
Mechanical
Electrical
Structural
PublicHealth
Construction
Management
The AusƟn Company of UK Ltd – Cardinal Point, Park Road, Rickmansworth, Herƞordshire, WD3 1RE – Telephone: 01923 432 658 – Fax: 01923 432 795 – enquiries@ auƐƟn.co.uk – ĂƵƐƟn.co.uk
xxvi © Woodhead Publishing Limited, 2010
1
Heat and mass transport processes in building materials M. R. H a l l, University of Nottingham, UK and D. A l l i n s o n, Loughborough University, UK
Abstract: This chapter introduces heat and mass transport in terms of the fundamentals and their application in the field of materials and building physics. It is the scientific topic that underpins all aspects of energy efficiency and thermal comfort in terms of the materials that make up our buildings and occupied spaces. An overview of thermodynamics and the conservation laws are provided to serve as a refresher for some readers and as a basic introduction for others. The chapter then deals with heat transfer by providing explanations of the fundamental science and then applying this to topics that are relevant to material properties and their application in buildings. The introduction of mass to these materials (e.g. water) adjusts the thermal properties, which in turn can alter the driving potentials for mass transport, which affects the thermal properties, etc., hence the true situation in materials is fully transient and highly time dependent. It is essential to consider this for accurate analysis and understanding of fabric behaviour, or of the indoor environment behaviour in response to the fabric it is made of. It is also an essential approach for studying phenomena such as surface and interstitial condensation, mould growth, as well as implications of changes to fabric (e.g. retrofit upgrades) and for thermal comfort. Therefore the next section in the chapter introduces mass transport where the approach is to, again, provide explanations of the fundamental science and then apply this to topics that are relevant to material properties and their application in buildings. Clearly mass transport is a subject in its own right, as is heat transfer. However, the chapter concludes by making the important point that in reality the two occur simultaneously and are inter-dependent, which leads on to the subject of hygrothermal behaviour. Key words: heat and mass transfer, porous materials, thermal properties, hygric properties.
1.1
Introduction
This chapter aims to explain and discuss the fundamental laws and processes that apply to the transport of heat energy and mass within the context of the fabric of buildings, i.e. the materials from which they are made. The chapter does not attempt to replace the multitude of excellent key texts already available on the general subject of heat and mass transfer and instead points to references and sources of further information where the reader may wish 3 © Woodhead Publishing Limited, 2010
4
Materials for energy efficiency and thermal comfort in buildings
to deepen their knowledge. Its objective is to serve as a learning tool for keen students as well as a ‘one stop’ revision/reference tool for experienced researchers.
1.1.1 Laws of thermodynamics As far as we understand, all matter possesses a quantity of mass and a quantity of energy. These two values are inextricably linked and we can assume that their total quantities never change – referred to as the laws of conservation of mass and conservation of energy, respectively. The reasons for this are explained in the following section. The further implications are that energy and mass are constantly moving from one place to another. Energy is formally described as the capacity of a system to do work and can occur either as potential energy (i.e. that stored in a body such as nuclear, electrical, etc.) or kinetic energy (i.e. energy of motion). The internal energy, U, of a body is the sum of potential and kinetic energies between component atoms and molecules, the total quantity of which is measured in Joules, and manifesting itself as the physical property of temperature. One can express this as a thermodynamic temperature, T in Kelvin (K) or as a Celsius temperature, q in degrees Celsius (°C). Note that a temperature of zero on the Kelvin scale (–273.15 °C) is called absolute zero because in theory it is the coldest possible temperature when internal kinetic energy is zero. When the temperature of matter in one region is higher than that in another region, transport of energy will attempt to occur from the hotter body to the cooler body until temperature equilibrium is restored. When energy is in transport from a higher temperature body to a lower one, it is described as heat energy. Mass is formally described in terms of its inertia (i.e. its resistance to acceleration), although it can also be measured in terms of the gravitational force it exerts on other objects, or (in practice) as the force by which it is gravitationally attracted to the Earth’s mass, i.e. its weight. Mass transfer is when transport of matter occurs from a higher concentration of mass in one region to a lower concentration in another. One can immediately appreciate how and why heat and mass transport occurs and the importance that this has within the context of this book. A popular phrase that is used to describe the first law of thermodynamics is that ‘heat is work and work is heat’. Work, W is the fundamental physical property in thermodynamics and simply describes motion against an opposing force, i.e. 1 Joule (J) is equal to the energy needed for 1 Newton of force to push an object over a distance of 1 metre. The energy of a system can be changed either by the system doing work, doing work on the system, or by transferring energy to or from another system in the form of heat. A ‘system’ in this sense can include a control volume of a material, e.g. a collection of molecules. An ‘open system’ is one where both matter and energy are
© Woodhead Publishing Limited, 2010
Heat and mass transport processes in building materials
5
free to enter or leave. In a ‘closed system’ only energy is able to enter or leave, whilst in an ‘isolated system’ neither mass nor energy can enter or leave. In a non-isolated system, the internal energy (U), can be changed by the transport of mass, transport of heat energy (Q; unit = Watts), or by the system doing work. An adiabatic system is one where, theoretically, there is no transfer of heat. The first law of thermodynamics can now be written such that for an adiabatic system Q = 0 and so DU = W, whereas in a nonadiabatic system DU = Q + W, i.e. the conservation of energy law applies. We can expand this to include the concept of enthalpy, H, which describes the thermodynamic potential of a system, summing internal energy and the product of pressure and volume so that H = U + PV. The second law of thermodynamics can be explained by the assertion that heat energy cannot of itself pass from one body to a hotter body. This suggests that the natural process of heat transfer is irreversible since heat cannot pass between two systems in thermal equilibrium with one another, nor can it pass from a cooler system to a hotter one. From this observation we create the concept of entropy, S which is a measure of the unavailability of energy to do work. The second law can be used to relate temperature and entropy to heat input/output, Q from a non-isolated system. This enables us to re-write the first law equation as DU = TDS – W. Following on from the previous explanation of the first law of thermodynamics, we can combine this with the second law under Clausius’ Dictum, which states that the total amount of heat energy in an isolated system is constant and the entropy of the system tends to increase (over time) towards a maximum. This results in a prediction known as the heat death of the universe, assuming that it is an isolated system, where entropy would tend to maximum and no more work could be done. Finally, there is the third law of thermodynamics and the zeroth law of thermodynamics. The third law states that for a perfect crystalline solid at absolute zero (0 K) DS = 0, enabling absolute values for entropy to be stated with reference to this point. The zeroth law logically concludes that if two non-isolated systems are in equilibrium with a third system, then all systems are in equilibrium with each other. Heat capacity is an important material property that can have significant effects on heat transfer. The specific heat capacity at constant pressure, cp (W/kg K) is the energy required to raise the temperature of 1 kg of a material by 1 K. If the temperature difference across a material changes, the heat capacity (along with the thermal conductivity) will largely determine how long it takes for the temperature gradient to form within that material. This is an important concept and is recurring throughout this chapter and the rest of the book. For further detail on the laws of thermodynamics and their implications for the properties of matter, see Atkins’ Physical Chemistry (Atkins & De Paula, 2006).
© Woodhead Publishing Limited, 2010
6
Materials for energy efficiency and thermal comfort in buildings
1.1.2 Conservation laws The conservation laws are an essential prerequisite for understanding how and why the transport of energy (in the form of heat) and mass actually occur and how it involves matter. These principles can be accurately described using classical physics, which is perfectly accurate for engineering-scale situations without resorting to a quantum mechanics approach and is more than enough for materials and building physics in this context. The classical physics approach to conservation in energy (heat) and mass transport is the foundation of the subject of transport phenomena and is dealt with very comprehensively by Bird et al. (2001) in their landmark textbook Transport Phenomena. This section provides an overview of the concepts as a prelude to heat and mass transport in materials. To begin, we must consider a material at the molecular level and we can use the simple example of one oxygen molecule (in air) colliding with another oxygen molecule (adapted from Bird et al., 2001). According to the law of conservation of mass, the sum of masses entering and leaving the collision must be equal:
mA + mB = m¢A + m¢B
1.1
where mA = m¢A and mB = m¢B. According to the law of conservation of momentum, the sum of momenta entering and leaving the collision must be equal: m r· + m r· + m r· + m r· A1 A1
A2 A2
B1 B1
B2 B2
= m¢A1r·¢A1 + m¢A2r·¢A2 + m¢B1r·¢B1 + m¢B2r·¢B2
1.2 · Note that rA1 is the position vector of atom 1 in molecule A, whilst rA1 is the velocity of that atom and hence the linear momentum, p = mxr·A1. The centre of mass of molecule A is at position vector rA, and the distances of each atom from this point are RA1 and RA2, respectively. Note that rA1 = rA + RA1 and that RA1 = – RA2, and that the same rule applies to velocity such · that r·A1 = r·A + rA1. This means that the conservation of momentum equation can be reduced to: m r· + m r· = m¢ r·¢ + m¢ r·¢ 1.3 A A
B B
A A
B B
Finally, the law of conservation of energy states that the sum of the energies of the colliding molecules must be equal before and after the collision. Following on from the second law of thermodynamics, if one of the molecules has more energy (higher temperature) than the other before the collision, energy will transfer in the form of heat from the hotter molecule to the colder molecule. The interatomic potential energy, fA is the force of the chemical bond joining the atoms. The law of conservation of energy gives us: © Woodhead Publishing Limited, 2010
Heat and mass transport processes in building materials
7
1 1 ˆ Ê1 ˆ Ê1 2 2 2 2 ÁË 2 mA1rA1 + 2 mA 2 rA2 + f A ˜¯ + ÁË 2 mB1rB1 + 2 mB 2 rB2 + f B ˜¯
1 1 ˆ Ê1 ˆ Ê1 = Á mA¢ 1rA1 ¢ 2 + mA¢ 2 rA2 ¢ 2 + mB¢ 2 rB2 ¢ 2 + f A¢ ˜ + Á mB¢ 1rB1 ¢ 2 + f B¢ ˜ 1.4 2 2 ¯ Ë2 ¯ Ë2
The total energy within a molecule is the sum of kinetic energies of the atoms plus the interatomic potential energy and is given by: 2 2 1.5 u A = 1 mA1rA1 + 1 mA 2 rA2 + fA 2 2 · · · From the r·A12 term recall that r·A = r·A + rA, and that rA1 = – rA2, therefore the law of conservation of energy reduces to:
ˆ ˆ Ê1 Ê1 2 2 ÁË 2 mA rA + u A ˜¯ + ÁË 2 mB rB + u B ˜¯
Ê = Á mA¢ A¢ 2 Ë2
ˆ u A¢ ˜ ¯
Ê 2 ÁË 2 mB¢ B¢
ˆ u B¢ ˜ ¯
1.6
Note that the energy of the molecule (including vibration, rotation and potential energy), and the kinetic energy of the molecule are distinct. However, in collision with another molecule kinetic energy can be converted into internal energy and vice 1 versa. 1 = + r + we are dealing with heat transfer To summarise, inr the+following sections which is the transport of energy as heat, and mass transfer which is the transport of mass. Clearly both involve all of the conservation laws and it is a useful starting point towards appreciating how and why the proceeding behaviours occur.
1.2
Heat transfer: the transport of energy
Heat transfer is the transport of energy that results from temperature difference. For the occupied space, this heat transfer may be undesirable, as in the heat loss through the walls of a heated building in winter or the heat gained through the windows of a car on a hot summer’s day. It may also be desirable, such as the use of the winter sun to warm the interior of a building or cooling by natural ventilation. In order to control the temperature within a space we must understand and try to quantify the mechanisms by which heat is gained and lost. This section offers an introduction to heat transfer by conduction, convection and radiation, as well as the effects of heat capacity on heat transfer. Heat may also be transferred by the movement of moisture (especially in vapour form) and this mass transfer is covered in Section 1.3.
© Woodhead Publishing Limited, 2010
8
Materials for energy efficiency and thermal comfort in buildings
Ventilation can be extremely significant in terms of heat gain and loss from a building and is considered separately in Chapter 3.
1.2.1 Dry state thermal conduction Thermal conduction is the transfer of internal energy (as heat), which occurs between neighbouring molecules of a solid, liquid or gas and between different materials in close contact with each other without the need for any bulk movement of that material. The rate of conduction heat transfer is proportional to the temperature gradient and the coefficient of proportionality is termed the thermal conductivity, l (W/m K). As heat flows from a location of higher temperature, T (K), to one of lower temperature, heat flux q (W/ m2) by conduction can be described, in one dimension, y (m), by Fourier’s Law of Thermal Conduction (see Fig. 1.1): The temperature can vary in all three dimensions simultaneously such that the x and z axes can also be written:
qx = – l
∂T ∂T and qz = – l ∂x ∂z
1.7
The simultaneous heat fluxes in each dimension can of course be written as a single flux with temperature divergence, if the x, y, z vectors are known, to give the more general expression:
q = – l—T
1.8
For a thermally homogeneous material of known thickness, d (mm) with surface temperatures T1 at x = 0 and T2 at x = d, under steady state conditions we get a steady state temperature gradient as shown in Fig. 1.2. T1
y d
where t is small qy = – l ∂T ∂y
T(y, t)
x
T2
1.1 Temperature gradient evolution in a material as a function of time. T1
y d x
T(y)
where t is large and l(T2 – T1) qy = can be neglected d
T2
1.2 Steady state temperature gradient across a material.
© Woodhead Publishing Limited, 2010
Heat and mass transport processes in building materials
9
The thermal conductivity of a material is typically measured by a steady state method such as heat flow meter apparatus that complies with ISO 8301 Thermal Insulation – Determination of Steady State Thermal Resistance and Related Properties, or guarded hot box apparatus (BS EN ISO 8990). In the field, thermal conductivity of materials in situ can be measured by heat probe methods (Pilkington et al., 2008; Bristow, 1998), or heat flux meters (Doran, 2000). The ‘as built’ conductivity of materials is often found to be higher than the design value and this can be due to a number of factors including degradation with age, weathering, dirt and moisture accumulation, thermal bridging and construction defects. Doran found ‘as built’ U-values were on average 20% higher than design values for wall and ceiling constructions in the UK (Doran, 2000). ISO 10456 (1999) gives methodologies for the calculation of the change in thermal conductivity when influenced by variations in specimen moisture content, temperature and age based on tables of factors that are given for a number of common materials. Thermal conductivity of porous building materials can be greatly affected by their moisture content and it is important to be aware of the moisture content of the material being tested. Relationships between moisture content and thermal conductivity can be determined experimentally (ISO 10051, 1996). For building fabric, the overall thermal transmittance, U is often termed the ‘U-value’ (W/m2 K) which is simply the reciprocal of the total thermal resistance, RT for a fabric of known thermal conductivity, l and thickness, d. The thermal resistance or ‘R-value’ (m2 K/W) of a material or layer is equal to d/l and multiple resistances are commutative, e.g. in the case of a wall RT = Rbrick + Rair cavity + Rconcrete + Rplasterboard. Indoor and outdoor surface resistances (Rsi, Rso) can be included as discussed below. This is analogous to electrical resistance since q = DT/R for resistances in series. Note, in the equation above, that a thermal resistance has been attributed to the air cavity. Clearly heat transfer across a fluid-filled space in this sense would occur by natural convection although fluid conduction also occurs. The use of a single resistance term is to treat this heat transfer as a conductive term, for convenience, by expressing the equivalent resistance offered as a result of the convection coefficient in the cavity. This can be calculated in each case but standard tabulated values are normally used depending upon flow direction and whether the cavity is ventilated or unventilated. For further information and for typical values, refer to CIBSE Guide A (CIBSE, 2006). In a similar manner, the complex fluid–surface interactions that occur at the boundary when air meets the wall surface, for example, can be reduced to a single ‘equivalent resistance’ term. These values take into account the convection coefficient for any solid-fluid heat transfer, as well as short wave radiation gains by the solid, and long wave radiation gains/losses by the surface. Again, standard values for internal surface resistance (Rsi) and
© Woodhead Publishing Limited, 2010
10
Materials for energy efficiency and thermal comfort in buildings
outside surface resistance (Rso) have been produced for convenience (CIBSE, 2006).
1.2.2 Moisture-dependent thermal conduction From the previous section it can be seen that if T1 and T2 are known for a material of thickness d, then l can be calculated simply by measuring the heat flux through the material under steady state conditions. For porous materials, they absorb and store a certain amount of moisture from the air (depending upon the relative humidity) and can absorb liquid water, e.g. by rainfall or by capillarity from the ground (see Section 1.3 for more details). This has an effect on the thermal conductivity of the material that, for some materials, is very significant and for others is less so. Heat flow meter apparatus can be used to test materials in their fully dry state, when partly moist (referred to as unsaturated), or when fully saturated (Hall & Allinson, 2008a). Under steady state conditions, the thermal conductivity (l) of the specimen is calculated using: ls ·[(k1 + (k2 · T )) + ((k3 + (k4 · T )) · HFM )
l=
+ ( k5 k6 T HFM 2 (( + ( dT · )) · )]
1.9 The values for the calibration constants of the apparatus k1 – k6 inclusive are determined separately, and the Heat Flowmeter Output (HFM) is measured in mV. Steady state conditions are deemed to occur when the percentage variation in heat flux throughout the sample is ≤ 3%. The sample interval of the heat flow meter is given by the greater of 300 seconds or:
rCslsR
1.10
Prior to testing for moisture-dependent thermal conductivity, specimens (normally in the form of a thin slab) are oven dried at 105 °C to constant mass to give a moisture content of zero (Hall & Allinson, 2008a). They are then wrapped in a thin vapour-tight membrane and sealed using a small amount of adhesive around the sides (not in contact with hot/cold plates) of the specimen. They can later be unsealed and sprayed with a pre-measured quantity of distilled water before being re-sealed inside the membrane and stored under ambient conditions for 48 hours to allow the moisture to distribute within the material. This process can be repeated each time increasing the water content until the specimens are submerged in a bath of distilled water to achieve full saturation. The thermal conductivity of the membrane must be pre-determined in order to factor it out of the final calculation. The moisture content-dependant thermal conductivity of a material, l* is defined under steady state conditions by ISO 10051 (1996):
© Woodhead Publishing Limited, 2010
Heat and mass transport processes in building materials
qm = – l* · dT dx
11
1.11
where qm is the measured density of heat flow rate at the hot and cold sides of the specimen (W/m2). The effect of moisture content on relative humidity was determined based on ISO 10051 (1996) Determination of Thermal Transmissivity of a Moist Material. Since the enthalpies of water vapour and liquid water are different from one another, the total flux, gt is equal to gv + gl (ISO 10051, 1996). When a temperature difference (DT) is applied across the specimen, the water begins to move around due to factors such as natural convection, diffusion and changes in capillary potential (see Section 1.3). In the early stages (when t is small), water close to the hot side can vaporise and migrate towards the cool side by diffusion. This has a significant effect in increasing q over that of a dry specimen since heat energy is transported sensibly by conduction through the solid and convection in the vapour, but also latently by the vapour which can condense near the cold side. As t becomes larger the accumulation of condensed water near the cold side can result in a gradient in capillary potential that induces liquid water to transport towards the warm side. Eventually the mass flux can become counterbalanced with vapour migrating from hot plate to cold plate and condensed liquid migrating from cold towards hot. Assuming that the sealed specimen contains a constant total amount of water, the counterbalancing situation is reached when:
g t = 0 ¤ g v = – g l
1.12
ISO 10456 (1999) Procedures for Determining Declared and Design Thermal Values provides methodologies for the theoretical calculation of the change in thermal conductivity when influenced by, for example, variations in specimen moisture content, temperature and age. l2 (the corrected thermal conductivity) is calculated simply by multiplying l1 (the measured thermal conductivity) by the moisture conversion factor Fm, where (ISO 10456, 1999):
Fm = efu(u2–u1)
1.13
The mass of moisture content in the second (wetter) state, u2, and the first (dryer) state, u1, is expressed in mass per mass units (kg/kg), as is the moisture content conversion coefficient, fu. A series of tables for standard values of fu can be obtained from ISO 10456.
1.2.3 Transient thermal conduction The heat capacity is significant when the dynamic (transient or time varying) heat transfer is considered. Two commonly used material characteristics that incorporate heat capacity are diffusivity and effusivity. Thermal diffusivity
© Woodhead Publishing Limited, 2010
12
Materials for energy efficiency and thermal comfort in buildings
is calculated from the ratio of the thermal conductivity to the volumetric heat capacity:
a= l rc p
1.14
Materials with a higher thermal diffusivity will reach thermal equilibrium with their surroundings more quickly. Thermal effusivity is calculated from the square root of the product of thermal conductivity and volumetric heat capacity:
b = lrc p
1.15
It can be used to infer the magnitude of heat transfer on contact with a material. For example, if one were to touch both timber and steel at the same room temperature, the steel would feel colder as it has a higher effusivity and heat is transferred from one’s hand into the material at a higher rate. The general form of the heat diffusion equation relies upon the conservation of energy principle (described in Section 1.1.2). It can be used as the basis to measure temperature distribution as a function of time in each of the three dimensions, T(x, y, z), and can be written as follows (Incropera et al., 2007):
∂ Ê l ∂T ˆ + ∂ Ê l ∂T ˆ + ∂ Ê l ∂T ˆ + = r ∂x ÁË ∂x ˜¯ ∂y ÁË ∂y ˜¯ ∂z ÁË ∂z ˜¯
p
∂ ∂
1.16
Note that q· is a heat energy source term associated with the rate of heat T q per c unit generation from the material measured as Watts volume of the z t material in question (W/m3). In a case of known dimensions, the effective length, L equals the distance between maximum and minimum points on a single temperature gradient. The quantity hL/l is a dimensionless parameter called the Biot number (Bi) that is used in transient conduction problems involving convection exchanges. It is effectively the measure of a temperature drop in the solid relative to the temperature difference between the surface of that solid and a fluid (liquid, gas or a gas/vapour mixture such as air) (Incropera et al., 2007).
R (L /l A) Ts,1 – Ts,2 Bi ∫ hL = cond = = l Rconv (1/hA) T ,2 – Ts• s
1.17
Figure 1.3 shows the effect of Biot number on the steady state temperature distribution established in a wall with surface convection at the wall–air boundary. The so-called lumped capacitance method assumes that T is uniform at any instant, even if decreasing as a function of time. This would
© Woodhead Publishing Limited, 2010
Heat and mass transport processes in building materials
13
qconv
qcond Bi << 1
Ts, 1
Bi ª 1
Ts, 2 T •, h
T Ts, 2 Ts, 2
Bi >> 1
x
1.3 Effect of the Biot number on a steady state temperature gradient in a wall Biot in wall (taken from Incropera et al., 2007).
T(x, 0) = Ti
T(x, 0) = Ti T•, h
T •, h
T• –L
L x
t
T•
T•
T• –L L Bi << 1 T ª T (t)
–L
L Bi ª 1 T = T (x, t)
–L L Bi >> 1 T = T (x, t)
1.4 Effect of the Biot number on temperature gradient evolution in different walls (taken from Incropera et al., 2007).
suggest l = • , or we can simply assume that temperature gradient exists but is negligible and can be ignored. When Bi << 1 the resistance to thermal conduction within the solid is much lower than the resistance to convection across the solid–fluid boundary layer. Therefore, the assumption of a negligible thermal gradient within the solid can be valid. The Biot number is also very useful for considering the evolution of thermal gradients inside a solid material (e.g. a wall) when the environmental conditions are changed. The example in Fig. 1.4 shows three walls and with very contrasting Biot numbers. Note that in a symmetrical case such as this, the wall thickness is taken as 2L since the effective length is that between the peak temperature (wall centre) and the lowest point. The walls are equilibrated at initial temperature Ti, and the temperature of the surrounding air is suddenly raised to T• < Ti. Note that, once more, when Bi << 1 the thermal gradient in the solid is negligible and so in this one-dimensional case T(x, t) ≈ T(t).
© Woodhead Publishing Limited, 2010
14
Materials for energy efficiency and thermal comfort in buildings
In contrast, when Bi >> 1 the majority of temperature difference evolves within the solid as opposed to near the solid–fluid boundary. With reference to the thermal diffusivity, and in addition to the Biot number, the second key dimensionless term that is essential for transient conduction is the Fourier number, Fo where:
Fo = a2t L
1.18
and
Bi · Fo =
hAs t rVc
1.19
From this we can calculate the temperature change of the solid over a period of time or the solid temperature at a known time, t using:
DT = Ti – T• = exp È– Ê hAs ˆ t ˘ = exp (– Bi · Fo) Í ÁË rVc˜¯ ˙ DTi Ti – T• ˚ Î
1.20
In cases where the simple lumped capacitance method is invalid (e.g. where Bi >> 1), temperature gradients can no longer be assumed to be negligible and so more sophisticated numerical methods must be used. A full review of these are beyond the scope of this chapter. Further details can be obtained by referring to Incropera et al. (2007). Some specific models and techniques are discussed in further detail later in this section. In all of the approaches to thermal conduction in building fabrics that have been discussed so far, the heat transfer has largely been assumed to be in one dimension. This is perfectly acceptable where energy efficiency and fabric heat loss/gain are the primary concerns. In situations where distribution of heat by conduction needs to be understood (e.g. due to thermal bridging around a column or a joint), then a two-dimensional or even three-dimensional approach may be required. One of the most common approaches is to use the Control Volume Method (CVM) which involves discretising the fabric in the form of a mesh, where thermal conduction between nodal points is considered. The finer the mesh, the closer the numerical result becomes to the true value; hence the complexity and scale of the mesh gives more accurate results at the expense of processing time. Many commercial software packages use an approach such as this, including FLUENT by ANSYS.
1.2.4 Thermal convection Convection occurs when there is conduction of heat into the molecules of a fluid and the bulk motion of that fluid that carries those molecules away
© Woodhead Publishing Limited, 2010
Heat and mass transport processes in building materials
15
from the heat source. Typically it is used to describe the heat exchange at a surface due to the movement of air across that surface. The air movement may be the result of natural convection due to the buoyancy of warmed (less dense) air immediately above a flat roof for example, or through forced convection caused by wind or vehicle motion and may be a combination of the two. It can be described in a form similar to conduction but introducing a convection coefficient, hc (W/m2 K):
qconv = hc(T2 – T1)
1.21
The value of the convection coefficient will depend on geometry (shape and orientation of surface), material properties (surface roughness), fluid properties (viscosity), fluid free stream velocity (speed and direction) and the temperature of the bulk fluid and the surface. These will determine whether the flow over the surface is buoyancy driven or forced, laminar or turbulent or, in fact, a combination of these. The complexity of the fluid dynamics has lead to the use of simplified empirical calculations. A couple of examples are given below and more can be found in recommended papers such as Cole and Sturrock (1977), McClellan and Pedersen (1997) and Liesen and Pedersen (1997). The CIBSE Guide C (2007) proposes a simple method of calculating the convection coefficient for external surfaces at any wind speed, cs (m/s) based on empirical wind tunnel experiments:
hc = 5.8 + 4.1 · cs
1.22
Standard BS EN 15026 (2007) gives a similar correlation (hc = 4 + 4 cs) and includes a note that cs has to be measured near the building’s surface, which is often not rigorously pursued in practice. It is important to point out at this stage that determining a correlation between the unobstructed wind speed at 10 m height above ground (unobstructed wind) and the surface resistance is very useful but that if this is not possible then constant values that have been validated for building applications should be used instead. An empirical method for calculating surface wind speed from the unobstructed wind speed is given in the ASHRAE Handbook (ASHRAE, 2005). The ASHRAE detailed algorithm (Energy Plus Engineering Reference Online, 2009) considers that the exterior convection coefficient comprises components due to natural convection, hn, and forced convection, hf, such that hc = hn + hf. The natural convection coefficient is described by Eq. 1.23 for upward heat flow and Eq. 1.24 for downward heat flow:
Ê 3 Tsurface – Tair ˆ hn,up = 9.482 Á ˜ Ë 7.238 – cos(f ) ¯
1.23
© Woodhead Publishing Limited, 2010
16
Materials for energy efficiency and thermal comfort in buildings
Ê 3 Tsurface – Tair ˆ hn,down = 1.810 Á ˜ Ë1.382 – cos(f ) ¯
1.24
Note that f is the angle of the surface from the horizontal. The forced convection coefficient is calculated from surface geometry, surface roughness and wind speed:
h f = 2.537 W f R f
Pvz A
1.25
where Wf relates to surface orientation (1 for windward surfaces), Rf is a roughness index (ranging from 2.17 for very rough to 1.00 for very smooth), P is the perimeter of the exposed surface (m), vz the local wind speed (m/s) and A the surface area of the fabric (m2). The choice of calculation method can make significant differences to the convection coefficient and ultimately the heat transfer and therefore care must be taken to validate models wherever possible. It should, however, be remembered that knowledge of the air speed at the surface may be equally important to the accuracy of any simulation and this can be difficult to determine, especially for the microclimate around vehicles and structures. Convection heat transfer also occurs inside porous materials, and it is the reduction in this term that gives insulating materials their low heat transfer properties. Solid insulation materials normally have a low density and contain a large proportion of pores (or voids) that are inter-connected such that they offer a very high level of resistance to any fluids attempting to pass through them, i.e. tortuosity (see Section 1.3 for further details). The purpose of so-called ‘insulating materials’ is to offer a very high level of thermal resistance (R, m2 K/W) and to be as thin as possible, i.e. l must be very low to ensure d does not have to increase. As with all materials, we know that the total thermal conductivity of an insulation material, ltotal is quantified with respect to the heat flux under steady state conditions at a known mean temperature. Consequently, the primary modes of heat transfer through insulating materials can be considered to have a cumulative effect in determining ltotal. The heat transfer modes in a typical porous insulation material can be described as: ∑ ∑ ∑ ∑
conduction through the solid material, lsolid conduction through fluid in the pores, lfluid radiation between the inside surfaces of pores, lrad natural convection through fluid in the pores, lconv.
Note that convective and radiative terms have been lumped as effective conductions, where
© Woodhead Publishing Limited, 2010
Heat and mass transport processes in building materials
ltotal = lfluid + lsolid + lrad + lconv
17
1.26
Clearly, in the case of building physics, the fluid can be air, air–water mixture or water, in which case lfluid can vary significantly and heat energy can also pass in latent form due to vaporisation/condensation of water as discussed in Section 1.2.2. This can have serious implications for the performance of insulation materials and highlights the obvious need for them to remain dry if they are to be effective. In conventional insulation materials with pore diameters greater than ~1 mm, the convective heat transfer component can represent a significant proportion of ltotal at standard temperature and pressure (STP). As pore diameters become smaller and the inter-connected paths between them become more tortuous, the movement of fluid becomes restricted and so convection becomes less dominant and the thermal conductivity of the quiescent fluid phase becomes the limiting factor. If we assume that the pores are filled with air, then quiescent air has a thermal conductivity of approximately 0.026 W/m K. If the pore diameters are sufficiently small then we can assume lconv = 0. In order for ltotal < 0.026 (W/m K) to occur, lfluid must be significantly reduced. The molecules in the fluid transfer kinetic energy to one another in the form of heat when they collide. The mean molecular free path is the average distance one of the molecules must travel before it collides with another of the same type. Therefore if this distance is reduced then lfluid must decrease because more molecular collisions need to happen in order to transfer the same quantity of heat energy across a distance d than before, which of course is statistically much less likely. The mean molecular free path in porous materials is reduced when the pore diameter becomes sufficiently small that molecule–pore wall collisions are statistically more likely than molecule–molecule collisions (Bird et al., 2001). The ratio of the mean molecular free path to a characteristic length (e.g. the mean pore radius in a porous material) is referred to as the Knudsen number which uses the symbol Kn. Note that in very permeable materials when Kn >> 1 it may be necessary to use the Monte Carlo method (or similar approach) to estimate the molecular trajectories inside the pore and hence predict the number of collisions. The net result is that when Kn ≥ 1, lfluid can be written as:
l fluid =
l 0fluid 1 + a · Kn
1.27
where l0fluid is the thermal conductivity of quiescent air, and a is a constant specific to the gas in the pores that is usually considered to be about 2 for air. Some solid porous insulation materials have extremely small pore diameters resulting in Knudsen numbers of about 1 to 2. This would give a lfluid term
© Woodhead Publishing Limited, 2010
18
Materials for energy efficiency and thermal comfort in buildings
of between about 0.0052 and 0.0087 W/m K. It is important to understand these phenomena because lately there has been increased attention towards ‘nano insulation materials’, such as aerogels (see Chapter 13), offering a high performance alternative to other thin insulation technologies such as vacuum insulation panels (VIPs, see Chapter 8). This means that because of the low lfluid in reality, a ltotal value of 0.016 W/m K or less can easily be achieved.
1.2.5 Thermal radiation Thermal radiation is electromagnetic radiation that is emitted by a body as a result of its temperature. All objects with a temperature above absolute zero emit thermal radiation in a spectrum of wavelengths. The amount of radiation emitted by a black body at any one wavelength is described by the spectral black body emissive power distribution or Planck’s Law, which may be written as:
E bl =
2p hc 2 10 l (exp(hc/lKT ) – 1)
1.28
6 5
Plotting the spectral emissive power for a black body against wavelength for a number of temperatures produces a series of curves, known as Planck’s curves, as shown in Fig. 1.5. The total emissive power can be found by integrating Planck’s law from
Spectral emmisive power, W/m2 mm
100000000
5762 K
10000000 1000000 100000 10000 1000 100
V i s i b l e
1250 K 800 K
300 K 250 K
10 1 0.1 0.01 0
1 2 3 4
5 6
7 8 9 10 11 12 13 14 15 16 17 18 19 20 Wavelength, mm
1.5 Planck’s isothermal curves for spectral emissive power vs. wavelength.
© Woodhead Publishing Limited, 2010
Heat and mass transport processes in building materials
19
l = 0 to l = ∞ (which gives us the area under the curve for a particular temperature) and is known as the Stefan–Boltzmann law: •
Ú0 E bl dl = E b = sT 4
1.29
where s is the Stefan–Boltzmann constant (s = 5.669 ¥ 10–8 W/m2 K4). The ratio of the emissive power, E, of a surface to the emissive power of a blackbody, Eb, at the same temperature is known as the emissivity, e (i.e. e = E/Eb), therefore:
E = esT 4
1.30
A black body is defined as a body that absorbs all incident radiation at any given temperature and wavelength. Real surfaces, however, absorb and reflect thermal radiation and may also transmit thermal radiation, as shown in Fig. 1.6, and this behaviour can vary with temperature and wavelength. Kirchoff’s law tells us that the amount of radiative energy emitted by a surface must equal the amount of radiative energy absorbed by that surface. The material properties of interest are therefore the absorbtivity (a) or emissivity (e), reflectivity (r) and transmissivity (t), which describe the fractions of the incident radiation that are absorbed, reflected and transmitted such that a + r + t = 1 and e = a. The net radiant heat transfer between two surfaces is dependent on their temperatures, sizes and view factors. Radiation view factors describe the fraction of the surface area of the hemispherical view from a surface that comprises the other surface. Techniques for determining view factors include mathematical, reference tables, ray tracing and fish eye lens photography and other methods that can be applied to urban areas (Grimmond et al., 2001). Incident radiation
Reflected
Absorbed
Transmitted
1.6 Absorption, reflection and transmission of incident thermal radiation by a material.
© Woodhead Publishing Limited, 2010
20
Materials for energy efficiency and thermal comfort in buildings
An example of their use would be for the long wave radiative heat exchange between a surface and the external environment. This could be divided into that between the surface and the ground, Fgnd, the surface and background objects, Fbg, and the surface and the sky, Fsky. Assuming temperature could be assigned to each of these: Tgnd, Tbg and Tsky, according to Mcclellan and Pedersen (1997) the radiative heat exchange at the surface can be simplified to: 4 q = es(Fgnd(T 4gnd – T surface ) + Fbg(T 4bg – T 4surface) 4 4 + Fsky(T sky – T surface))
1.31
where Fgnd + Fbg + Fsky = 1. The determination of the ground, background and sky temperatures must also be considered. For inside surfaces such as the walls, floor and ceiling of a room, other methods have been developed such as the one described by Liesen and Pedersen (1997). Radiation that originates from the sun, which has a black body temperature of around 6000 K, has a much shorter wavelength than that from objects at typical terrestrial temperature and for this reason is termed short wave (SW) radiation. This is a useful distinction as a material’s wavelength dependent behaviour to thermal radiation can be split into LW and SW for convenience. A commonly used example is snow, which has a very low emissivity in the short wave (highly reflective) and a very high emissivity in the long wave (highly absorbent). The gas molecules and solid particulates that make up the earth’s atmosphere absorb, reflect and scatter solar radiation; the intensity at the surface is therefore dependent on the sun’s relative position and the atmospheric conditions. Cloud cover is an obvious example of this dependence. The solar radiation that is incident on a surface can be divided into that direct from the sun, diffuse radiation from the sky and reflected radiation from the ground and other surfaces. When the surface is transparent, such as glass, a portion of this radiation will be transmitted into the room, a portion reflected away from the surface and a portion absorbed by the glass. Different methods for calculating these effects have been developed (see, for example, CIBSE, 2006 and McClellan and Pedersen, 1997).
1.2.6 Steady state environmental parameters The ratio of temperature change across a boundary is proportional to the ratio of thermal resistances such that (McMullan, 1992):
DT = R TT RT
1.32
where ΔT = temperature difference across a layer, TT = total temperature difference across the element, R = resistance of that layer, and RT = total
© Woodhead Publishing Limited, 2010
Heat and mass transport processes in building materials
21
resistance of the element. The formula can simply be rearranged to give the temperature difference (DT) across each boundary layer within a multilayer fabric, e.g. a wall. This technique is referred to as the Glaser Method and is illustrated in Fig. 1.7. Surface resistances are included to make surface temperatures more realistic; these are usually taken as tabulated values from the CIBSE Guide A (2006) or similar. The choice of values depends upon level of exposure and air velocity near the surface, e.g. typical Rsi = 0.123 m2 K/W. A similar approach is taken for air pockets, for example in a cavity wall where standard values are assumed for ventilated or unventilated cavities. The main weakness of this model is that the two temperature set points (T1 and T2) are taken from indoor/outdoor air temperatures which ignores additional gains or losses through the fabric as a result of radiation or convection. This is important because the temperature profile will be less accurate and surface temperatures can be very inaccurate, e.g. on a hot sunny day surface temperature can
Inside air temp.
Temperature (°C)
20
10
Outside air temp. 0 Inner wall (brick)
Air cavity
Outer wall (brick)
EPS insulation
1.7 Glaser’s method for steady state temperature gradients in a multilayer composite wall.
© Woodhead Publishing Limited, 2010
22
Materials for energy efficiency and thermal comfort in buildings
exceed air temperature due to solar gain but a standard Glaser model would show it as being lower. These problems can be overcome by using a more complex Glaser method which uses nodal points as opposed to fixed air temperatures. These nodal points are hypothetical ‘equivalent’ temperatures that lump together a more complete variety of heat energy inputs. Instead of an outdoor air temperature point, a sol-air temperature node is used; a hypothetical temperature that includes the outside air temperature, SW radiation gains (from the sun), LW radiation gains from surrounding objects, and convective exchanges. The indoor air temperature is replaced by two nodal points: environmental temperature node and air temperature node. The environmental node includes convection from the room air, and radiation both from surrounding objects and direct sources, e.g. heaters/plant. Heat transfer occurs between the environmental node and the indoor air which is limited by the air convection transfer coefficient. Heat transfer from the sol-air node occurs directly to the indoor air node only in the case of infiltration (leakage), and to the environmental node in the form of conduction or conduction equivalents, i.e. it is regulated by fabric resistance RT. The nodal network diagram in Fig. 1.8 illustrates this model.
1.2.7 Transient environmental parameters The nodal diagram shown in Fig. 1.8 is used under steady state environmental conditions, where nodal temperatures are fixed values, e.g. using only the mean value for a day, month or season. However, it can also be extended for use with dynamic environmental conditions where the sol–air and environmental node temperatures fluctuate between maxima and minima about a mean. This principle is employed in the cyclic admittance method (see CIBSE Guide A, 2006) where the periodic fluctuation about mean values is taken to be a sinusoidal frequency pulse, normally over a duration
Indoors Qie QSe QaU QPa Qia QSa
Wall 1 S AU
qei
Outdoors
qeo
1 hc S A qai
1 pC pV
1.8 Nodal network diagram for the admittance model under steady state conditions (adapted from Rees et al., 2000).
© Woodhead Publishing Limited, 2010
Heat and mass transport processes in building materials
23
of 24 hours. This approach has the disadvantage that the resistances (and hence the associated material properties) are assumed to be constant, which if rigorously pursued is invalid except under steady state conditions since l is temperature dependent. However, the accuracy is normally perfectly acceptable across the temperatures ranges used in building physics. Obviously the sinusoidal temperature fluctuations are also an assumption because 24 hour cycle temperature changes do not follow this precise pattern. However, this assumption does offer the advantage of being able to compare the behaviour of one cross-sectional fabric with another under identical timedependent environmental conditions. In order to adapt the nodal diagram for dynamic environmental conditions the terminology is changed slightly, as shown in Fig. 1.9. Note that the Celsius temperatures and nodal heat inputs/outputs are shown with a tilde symbol to denote fluctuation which occurs simply as a function of time. The other significant change is the replacement of steady state transmittance, U, with thermal admittance, Y, for fabric conduction, where U is the rate of heat transfer across a fabric, and Y is the rate of transfer to the fabric, with identical units (W/m2 K). Unlike U, which is simply the reciprocal of RT, Y is calculated using a set of matrices which employ density, heat capacity, thickness and thermal conductivity (see CIBSE Guide A, 2006). As a result, heat transfer from the environmental node to the fabric (and subsequent storage of heat energy) can be approximated using the admittance method which is useful for determining any reductions in peak cooling loads inside a building. High thermal admittance is one of the two most important features of fabrics that are referred to as having ‘thermal mass’. This is also an important concept when considering passive cooling as a result of fabric energy storage, and is discussed in more detail in Chapter 4. The second important feature of thermal mass fabrics is that of thermal decrement factor, f. This is used to represent the reduction in temperature
Indoors
Wall
Outdoors
~
Q ie ~
Q se
1 SAY
~
q ei
~
~
Q aU ~
Q Pa ~
Q ia ~
Q Sa
q eo
1 hc S A ~
q ai
1 pC pV
1.9 Nodal network diagram for the admittance model under transient environmental conditions (adapted from Rees et al., 2000).
© Woodhead Publishing Limited, 2010
24
Materials for energy efficiency and thermal comfort in buildings
gradient formation (as a function of time) across a fabric as a result of heat storage within that fabric, and hence the rate of heat transfer is attenuated by the factor f. This forms an additional component to calculating peak cooling load. It can also be used in conjunction with the nodal diagram for a sol–air temperature fluctuating as a function of time, t, to approximate the response of the environmental node temperature which of course now fluctuates as a function of f. In this situation, decrement has an associated time lag, f (hours), which causes the maxima and minima to move out of phase with the sol–air node temperature as shown in Fig. 1.10. The consequences of this behaviour are that low thermal mass walls tend to exhibit less attenuation of environmental temperatures (dashed lines) in response to sol–air fluctuations (solid lines) and with a shorter decrement time lag than do high thermal mass walls. This translates to reduced potential for heat transfer from the environmental node to the indoor air node since the temperature gradients between the two will be lower. Since thermostatic controls for HVAC systems typically use indoor air temperatures, high decrement fabrics can (in theory) be used to reduce the heating cooling loads considerably. One final point is that since decrement applies to heat transfer across the fabric, it is used to attenuate U as opposed to Y for heat loss/gain to the environmental node. This is very important for building fabric design because it is possible to optimise material type, thickness and positioning in relation to heat gain/loss (U), passive cooling (Y), and suppression of temperature fluctuation (f, f). Examples are given in Fig. 1.11 using different
P
f
Inside
max qeo
Outside
Wall
qeo(t)
Aeo
Aei
qeimax qi
qei(f )
t
max qei
qeimin
x=0
x=L
t
min qeo max qeo
1.10 A diagrammatic illustration of thermal responses in the admittance model (adapted from Asan, 1998).
© Woodhead Publishing Limited, 2010
Temp (deg C)
25
x = L
x = 0 x = L
Solid wall
Insulation 25
qeo(t)
20
5 10 15 20 t (hours) Y = 4.8 U = 1.9
5 10 15 20 t (hours) Y = 0.29 U = 0.29
x = 0
5 10 15 20 t (hours) Y = 0.29 U = 0.26
x = 0 L 1 L 2 x = L 3
25
qeo(t)
20 qei(f )
15
5 10 15 20 t (hours) Y = 4.7 U = 0.26
x = 0 L 1
L 2 x = L 3
Composite walls 25
qeo(t)
20 qei(f )
15
L 1 x = L 2
Externally insulated 25
qeo(t)
20 qei(f )
15
x = L2
Internally insulated 25
qeo(t)
20 qei(f )
15
x = 0 L 1
20 qei(f )
15
qeo(t)
5 10 15 20 t (hours) Y = 5.1 U = 0.26
qei(f )
15
5 10 15 20 t (hours) Y = 0.3 U = 0.26
Heat and mass transport processes in building materials
© Woodhead Publishing Limited, 2010
x = 0
1.11 Comparison between Y, U and f for different fabric design configurations (taken from Hall & Allinson, 2008b).
25
26
Materials for energy efficiency and thermal comfort in buildings
configurations of a 300 mm dense concrete wall with 100 mm of polystyrene insulation. The U value is essentially unaffected by positioning of the insulation, but admittance and decrement both are. Internal insulation gives very low admittance, opposite for external insulation. It is possible to have too much mass in one place; if it is too thick it is harder for heat energy to pass deeply enough from the environmental node in sufficient time and it starts to ‘leak’ towards the sol–air node. Optimum thicknesses of the high thermal mass material (in this case concrete) exist; they must be positioned on the inside in contact with environment and air. The exact thickness varies with material properties but for conventional mass materials (e.g. dense brick, concrete, compressed earth) this value is between 100 and 200 mm. Commercial software packages that use this approach for modelling heat transfer with transient environmental conditions include Ecotect and HEVACOMP, and it is the approved method for CIBSE. An alternative approach to the admittance method is to use a ‘heat balance method’ approach. This looks at the cross-sectional fabric as above by considering the resistive/capacitive thermal properties, but more realistically simulates heat energy fluxes to and from the fabric. For further details of this method refer to the ASHRAE Fundamentals set of handbooks. For 2D and 3D problems the usual approach is to use a CVM for numerical modelling or a commercial package such as FLUENT. The various approaches and techniques to modelling heat transfer are beyond the scope of this chapter. The admittance and heat balance methods are discussed in more detail in Chapter 4 with particular regard to their application for thermal storage and cooling loads.
1.3
Mass transfer: the transport of matter
Mass transfer is inextricably linked with heat transfer and is the study of the mechanisms responsible for the transport of matter (normally as a fluid) from one place to another. The following section explains the fundamental concepts of mass transfer and combines this with the subject of porous materials and in the context of building physics.
1.3.1
Psychrometrics
Psychrometrics (as distinct from psychometrics) is the study of the thermodynamic properties of air–vapour mixtures, typically focusing on the interrelation among temperature, partial pressures and enthalpy. Under normal atmospheric conditions the air in our atmosphere (mainly N2, O2, CO2 plus others) contains varying amounts of water molecules in vapour state. The moisture content of air is defined as the mass of water vapour molecules
© Woodhead Publishing Limited, 2010
Heat and mass transport processes in building materials
27
per unit mass of air molecules within a finite volume and is expressed in kg/kg. The pressure of a gas (air) or vapour (e.g. water) is the result of the mean kinetic energy associated with the Brownian motion of its molecules. We know from Dalton’s Law that when two gases are mixed, in this case air and water vapour, that the total pressure of the mixture is equal to the sum of the two pressures which are now called partial pressures. We also know from this law that partial pressures are commutative such that if the partial vapour pressure (per unit volume) increases, the air pressure stays the same and the total pressure increases by Dpv. The relative humidity, j, of the air–vapour mixture is defined as the partial vapour pressure as a proportion of the saturation vapour pressure within a finite volume at known temperature. It can be given either as the decimal value of the fraction pv/ pvsat or as a percentage. Note that the dew point temperature is the point at which water vapour in a known volume of air will condense, since it occurs at the point where j Æ 1 (or 100% RH). If a bulb thermometer is placed in the air–vapour mixture, the temperature recorded is a consequence of the internal energies of the gas and vapour, and is referred to as the dry bulb temperature. If the thermometer bulb is then surrounded by a wick saturated in liquid water, evaporation from the wick occurs, the rate of which is controlled by the temperature and moisture content of the surrounding air. Evaporative cooling of the surface results in a reduction of the measured temperature (called the wet bulb temperature), and the depression between this and dry bulb directly corresponds to the relative humidity of the air. On this basis, a psychrometric chart (see Chapter 4 for further details) can be plotted linking dry bulb and wet bulb temperatures to corresponding relative humidities, which in turn have corresponding partial vapour pressures (and therefore moisture contents) and dew point temperatures. Note that the enthalpy of the air corresponds to the sum of the internal energies of the gas molecules and water vapour molecules.
1.3.2 Porous materials Porous materials contain voids (or pores), either in isolation or interconnected to form complex networks of channels, which are filled with fluid under normal atmospheric conditions, e.g. air, liquid water, or air and water vapour. Depending upon the permeability of the material, fluids are able to enter or leave the voids and to move along within continuous voids. Therefore, all permeable materials are porous but the degree to which porous materials are permeable varies considerably. It can even tend towards zero for materials with isolated or closed voids. The permeability of a porous material can be quantified and expressed as a coefficient to describe the restrictions imposed on fluid flow. These restrictions can be attributed to a wide range of parameters such as the total volume of void space (i.e. bulk porosity, n), the void size
© Woodhead Publishing Limited, 2010
28
Materials for energy efficiency and thermal comfort in buildings
distribution, the extent of interconnectivity between voids, as well as minor factors such as the roughness of void interior surfaces. One other important factor is tortuosity, because we may have implicitly assumed up until this point that the interconnected voids are all straight with no corners or bends. When fluid is travelling from one point to another inside a continuous void the resistance to flow increases if the path becomes more ‘tortuous’ or challenging. This is due to the cumulative effect of the required number of changes in flow direction, the extent to which direction must be changed, variations in void diameter, and other possible examples. The permeability of porous materials is dealt with in more detail in Section 1.3.5. If the specimen of a porous material has a total volume, VT, which consists of solid state matter, Vs, and fluid-filled void, Vv, then VT ∫ Vs + Vv (see Fig. 1.12). Under atmospheric conditions, when the material is dry the voids are filled with air (Vv = Va) and when saturated the voids are filled with water (Vv = Vw). An interesting observation is that, when water enters a dry or partly dry (known as ‘unsaturated’) porous material, it must displace an equal volume of air from the moment it crosses the boundaries defined by VT; assuming the air to be incompressible. What can actually happen is that air is not always able to be displaced, which can prevent saturation occurring, and can even become trapped by advancing water at the ends of sealed voids with no escape. Its only option is to slowly dissolve in the water but this can take several months to occur. For these reasons full saturation rarely occurs except where the air in a porous material is first fully evacuated by placing in a vacuum chamber, and then introducing water to the sealed chamber and immersing the specimen; a process called vacuum saturation. Of course, one
Volumes
Voids Vv Total volume
Porous material
Masses
Air Va
AIR
Air ma
Water Vw
Water
Water mw
ma = 0
Total mass mt
Vt Solids Vs
Solids
Solids ms
1.12 The three phase model for porous materials.
© Woodhead Publishing Limited, 2010
Heat and mass transport processes in building materials
29
or more isolated pores can remain inaccessible to water even under these conditions since they are not connected to the rest of the void network. In this sense, the only true way to assess bulk porosity is to determine the specific gravity of the solid material, and gravimetrically determine the specimen’s mass as a fraction of maximum theoretical mass, where n = 0. Therefore, determining the porosity by gravimetrically measuring the maximum mass, of fluid that the voids can hold gives us the apparent density of the material or, conversely, the apparent percentage water absorption. When water enters the finite volume that we have described as VT (by entering the voids), we describe the process as absorption. Absorbed water molecules may also be ‘adsorbed’ to the internal surfaces of voids by van der Waals forces (since water molecules are polar). Absorbed water can be classified into one of three domains known as hygroscopic water, capillary water and gravitational water (Hall & Allinson, 2009a). The classification of the water is dependent upon (i) its phase (vapour or liquid) when it enters VT, and (ii) the extent to which it is electrostatically attracted to the inside surfaces of the void. Hygroscopic water is absorbed as a vapour phase, capillary water is absorbed as a liquid phase, and gravitational water is liquid that is absorbed when the capillary potential in the pore network is zero (i.e. super saturation). This latter point can be better understood following an appreciation of the phenomenon known as capillarity, as described in detail in Section 1.3.4. Suffice to say that the threshold between capillary and gravitational water is the point where electrostatic attraction between the water molecules and the void surfaces is insufficient to oppose the force due to gravity. It is helpful to describe the water content of a porous material in terms of relative water content, q. This is in fact a dimensionless value for the water content and can be calculated using (Hall, 1977):
q=
(w – wa ) (wb – wa )
1.33
where 0 ≤ q ≤ 1. Note that w = gravimetrically determined water content (kg/m3), and that wa = minimum moisture content and wb = maximum moisture content. In the following sections we will see how several critical values for q occur, and that their numerical values are (i) characteristic of particular materials, and (ii) correspond to the three domains of absorbed water described above.
1.3.3 Kelvin’s equation and sorption isotherms Since water molecules are dipolar they can attract and bond to one another through a type of van der Waals force known as hydrogen bonding. The
© Woodhead Publishing Limited, 2010
30
Materials for energy efficiency and thermal comfort in buildings
internal molecular attractive forces in water may be termed cohesion, whilst the forces of attraction that exist between water molecules and those of dissimilar materials (e.g. the negative charged surface of a void) may be termed adhesion. If the adhesion forces between water and a dissimilar solid (e.g. glass) are greater than the intermolecular forces within the water, then the surface of the glass becomes ‘wet’ (Bowles, 1984). The formation of droplets occurs because the internal intermolecular forces of a finite amount of water are in equilibrium with the atmospheric pressure of the surrounding air (see Fig. 1.13). Since the thickness of the surface tension ‘skin’ is molecular, it follows that the unit for surface tension is force/length (Bowles, 1984). The internal/external pressure difference, known as p (where p = pi – po), inside the curved surface of the droplet is directly proportional to the surface tension g, and therefore inversely proportional to the radius of curvature r (see Fig. 1.16). This is shown by the equation below where:
p=
2g r
1.34
Although the classification of absorbed water (determined by its phase upon entry) cannot change, its phase once inside VT can change, for example the condensing of hygroscopic water from vapour to liquid phase (Hall & Allinson, 2009a). This phase changing can occur depending upon factors such as geometry of the voids and electrostatic surface charge within the voids. The reason for this is the simple fact that the saturation vapour pressure above a curved surface of water is different from that of a completely flat surface. The saturation vapour pressure above a flat surface of liquid water, psat* (when r = •), is dependent upon the pressure applied to that liquid by the surrounding air. For a given air pressure, the saturation vapour pressure of the water becomes psat = psat *eVm DP /RoT (Atkins & De Paula, 2006). When g = surface tension R = radius of curvature
q
g
g
Atmosphere (air)
po
q
Water droplet
pi R qq
p = pi – po
where: p = total pressure pi = pressure inside droplet po = atmospheric pressure (outside droplet)
Glass surface
1.13 The formation of a water droplet (adapted from Bowles, 1984).
© Woodhead Publishing Limited, 2010
Heat and mass transport processes in building materials
31
the surface of the water is curved to a known radius, r, a pressure change (negative for water) occurs where DP = –2g/r (see above for droplet). Note that DP is referred to as the capillary potential, Y, which is used to quantify the motivation for capillarity and is often termed ‘suction’ because it is a negative pressure differential measured in Pascals. We can see that the saturation vapour pressure of water held inside a pore of radius r (and having a contact angle a) is less than that of a flat surface, i.e. psat < psat*. This of –2 V /rR T course leads to Kelvin’s equation, psat = psat *e g m 0 , where Vm = molar volume of water (~ 18 ml at STP), and R0 = the gas constant (Atkins & De Paula, 2006). In the case of hygroscopic moisture (vapour phase, of known partial pressure) that has been absorbed by a void, Kelvin’s equation can simply be rearranged to find the ‘critical radius’ of that void (rcrit), assuming pv = psat. At this point moisture vapour condenses inside the pore to restore thermodynamic equilibrium. Obviously, where radii vary within complex pore structures, it follows that vapour condenses to fill the pore with liquid when r < rcrit, and vice versa. This can lead to an interesting phenomenon known as the ‘ink bottle effect’, where a larger void has only narrow entry points. If r < rcrit at the entry points, but r > rcrit within the large void itself, then vapour can condense in the entry points effectively blocking the void from absorption or desorption. Kelvin’s equation can also be re-written so that if void radius is known, then the relative humidity, j, of air (where j = pv/psat) at which condensation will occur is given by:
j=
Ê 2g pv 1 ˆ = exp Á psat Ë r Rvap rwT ˜¯
1.35
where Rvap is the gas constant for water vapour (J/kg K) and rw the density of liquid water (kg/m3). It follows that in a porous material there are a wide range of voids and void sizes. As relative humidity increases the hygroscopic water increases, and so does the potential for some of this to condense to liquid inside the material because rcrit increases. Therefore at constant temperature, there is an equilibrium moisture content (EMC) for every value of j between 0 and 1 (some of which will condense if r < rcrit) that is characteristic of each porous material. Furthermore, some of the absorbed water molecules can be adsorbed by the surfaces of the void which raises their enthalpy of vaporisation correspondingly. This results in hysteresis between the EMC when Dj is positive (progressive wetting), and when Dj is negative (progressive drying). By plotting moisture content against j, a pair of sorption isotherms (or ‘moisture storage functions’) can be plotted for a particular material: a wetting isotherm and a drying isotherm (see Fig. 1.14). The gradient of an isotherm (below q80, where capillary condensation makes the isotherm slope increase rapidly) gives us a single value known as the sorption capacity, x. Once a material’s sorption isotherms have been
© Woodhead Publishing Limited, 2010
dw ∂ RH
Drying isotherm Wetting isotherm
0
10
20
30
40
50 RH (%)
60
70
80
90
100
1.14 A typical sorption isotherm with wetting and drying curves (taken from Hall & Allinson, 2009a).
Decreases
Increasingly wet Porous media
Suction pressure Increases
x=
Film of hygroscopic water
q80
Increasingly dry
qr
Hygroscopic water
Capillary condensation
Hygroscopic water
Multi molecular
Hygroscopic domain
© Woodhead Publishing Limited, 2010
Mono molecular
Capillary domain
Water molecule sorption
Pore spaces filled with air
qaev qc
Materials for energy efficiency and thermal comfort in buildings
qs
All pore space filled with water
10–7
Capillary water
10–8
Soil Pore spaces particles filled by air
5
Condensation
Critical pore radius (m) 10–9 2
5
Gravitational domain
3
32
Heat and mass transport processes in building materials
33
characterised in this way, the EMC can be interpolated for any value of j. Note that if j periodically fluctuates as a function of time, the EMC corresponds to the values on the wetting isotherm for the periods of time when Dj is positive, and then jumps across to the drying isotherm for the periods of time when Dj is negative. It is important to distinguish that the sorption isotherm enables us to predict how much time is needed for the moisture content to reach EMC once Dj has occurred. The response time of the material to Dj is measured separately using the moisture buffer value (MBV) test (DTU, 2005). Some materials have relatively high moisture storage functions (i.e. steep isotherm gradients) but low MBVs, which could be interpreted as having a larger capacity to store moisture as a function of j, but a slower response time to changes in j as a function of time. Other materials exhibit the opposite sort of behaviour, i.e. quick response times but lower storage capacity. The behaviour of materials in this respect is discussed in more detail in Chapter 14. The sorption isotherm in Fig. 1.14 also shows that at very low relative humidity, single layer adsorption followed by multi-layer adsorption of water vapour molecules occurs within the pore structure of the material. Metastable groups of adsorbed water vapour molecules can spontaneously nucleate into a liquid water meniscus that is in equilibrium with the relative humidity for a given pore radius (Hall & Allinson, 2009a). It is unclear how valid the assumptions of Kelvin’s equation become when the theoretical values for rcrit (which are constants at known T) reach this scale. It is logical to assume that the validity applies to the portion of a sorption isotherm where capillary condensation will occur in pore radii sufficient to permit thicknesses greater than multi-molecular layers (i.e. droplets) which typically occur at j ≈ 0.5. Despite this, the occurrence of significant liquid water flow (induced by dY/ dx) is typically not considered until j > 0.8 (Künzel, 1995). The reference moisture content for this value is referred to as q80 as shown in Fig. 1.14. Another point of interest on the sorption isotherm is the transition from hygroscopic domain to the capillary domain, which occurs at the hypothetical point when j Æ 1 (Hall & Allinson, 2009a). This corresponds to the value known as the residual moisture content, qr, which has to be interpolated as opposed to measured experimentally. For numerical modelling, the maximum hygroscopic moisture content that can be readily determined experimentally is normally taken to be 95 or 98% (Künzel, 1995; Valen, 1998). When q is in the capillary domain, water transport is dominated by capillary potential, Y, or ‘suction’ (Pa) and the microstructure is referred to as ‘unsaturated’.
1.3.4 Capillarity Capillarity (or capillary suction) is the natural phenomenon that many of us have experienced at an early age by placing one end of a narrow tube in a
© Woodhead Publishing Limited, 2010
34
Materials for energy efficiency and thermal comfort in buildings
tray of water and observing the rise of water inside the tube. We may also notice, by using a range of different width tubes, that as the radius decreases the height to which the water rises will increase. Referring to the portion of the sorption isotherm (see Fig. 1.14) above the residual water content, qr, we can see the so-called capillary domain. During wetting, absorption will continue until the relative water content is at capillary saturation, qc, at which point the total water pressure Pw = Pa – (2g/r + rwgh), for the supported mass of water inside the pore structure (where g is the gravitational constant 9.81 m/s2) (Atkins & De Paula, 2006). We already know that saturation vapour pressure above a curved water surface is different from that above a flat surface by the Kelvin equation. Water rises inside the capillary simply to offset the pressure differential between the water and the surrounding air (which includes air + water vapour). The maximum theoretical height that the column of water can achieve in a fully wet capillary is then given by:
h=
2g rrw g
1.36
As previously mentioned, gravitational water is liquid that is absorbed when the capillary potential in the voids is close to zero. We now know that this is additional water absorbed when the relative moisture content is > qc. When q >> qc we refer to this as the gravitational domain although it is often known as ‘super saturation’, because the water theoretically cannot enter by capillarity. It is perhaps obvious that, if qc << qs then additional water can be absorbed without capillarity (e.g. due to a pressure differential, gravity, etc.), some of which can be supported by remaining net surface charge in the void internal surfaces. Thus, on the drying curve the maximum capillary water content is determined by the air entry value which is designated qAEV. At the threshold for ‘super saturation’ (> qAEV) the force due to gravity on the additional mass of the non-capillary (or gravitational) water is greater than the attraction of the remaining net surface charge inside the pore structure. Vos and Tammes (1968) performed various experiments on the capillary movement of water and concluded that, amongst other things, water moving through a porous material by capillarity could travel twice as far in a horizontal direction as in an upward direction. This is because, in the latter case, the direction of flow is perpendicular to the force of gravity and so its effect in opposing the flow is at a minimum. If a temperature gradient exists along a capillary vessel, the flow of water within that capillary will occur in the direction of the lower temperature (Vos & Tammes, 1968). This is because the electrostatic potential of the void internal surfaces is a monotonously decreasing function of temperature. This occurs because of the principles surrounding the conservation of energy in a system. If a pocket of water is held in a cylindrical void of uniform diameter, and one end of the void is
© Woodhead Publishing Limited, 2010
Heat and mass transport processes in building materials
35
heated, the water moves towards the colder end. In addition, water that is held within a void of uniform temperature, but that has a tapering diameter, will move towards the narrower end of the capillary through inducement by the higher capillary potential. The actual electrostatic charge of the void’s internal surfaces is assumed to be the same, and so when the void radius decreases towards the tapered end, the term 2g/r becomes larger which increases Y. Consequently, if two porous materials are in contact with one another, water transport will occur from the larger diameter voids into the smaller diameter voids. This process occurs until the net gradient of pressure differentials has equilibrated (Vos & Tammes, 1969). Capillary conduction describes the flow of liquid water through the pore network. If the water content is sufficiently high (i.e. capillary saturation), then Y = 0 and the rate of flow of the water is governed by (i) fluid pressure differential and (ii) the resistance to flow offered by the material’s pore network, e.g. due to tortuosity. This saturated flow is governed by Darcy’s law and is explained in more detail in Section 1.3.5. When the water content is between qr and qAEV, the material is ‘unsaturated’. The gradient of capillary potential, Y (or ‘suction’) provides the motivation force for liquid transport in unsaturated porous materials. The liquid conductivity, K (s/m) is therefore dependent on capillary potential, and so the liquid water flux can be written as:
gl = K (Y ) ∂Y ∂x
1.37
We can see from Fig. 1.15 that Y can become extremely high in the hygroscopic domain and devices for measuring suction pressures (potentiometers) are typically designed for the capillary domain, making them incapable of measuring suction pressures of this magnitude. However, we know that Y = DP = 2g/r and so we now have the relationship:
Y = RvaprwT ln (j)
1.38
In this way, capillary potential can be approximated from the EMC corresponding to a given relative humidity, j. In an applied sense, when capillary domain water is absorbed into porous building materials a number of complexities can arise at various stages of the process. Hall (1977) used the classic example of a dry brick placed in a shallow tray containing clean water to illustrate this. From the moment this is done water is absorbed into the brick by capillarity and then attempts to distribute itself throughout the pore network. The absorbed water partially displaces the air that previously occupied the dry pores. At the surfaces of the material that are not immersed, the process of evaporation has begun to occur which results in a cooling of the surface. The resulting thermal gradient assists transport of water to the
© Woodhead Publishing Limited, 2010
36
Materials for energy efficiency and thermal comfort in buildings Residual air content
AEV
qs
Gravitational domain
Drying
qr 0 10
Capillarity only
Wetting
Capillarity + other
Relative moisture content
qaev qC
Capillary domain
Hygroscopic domain
100
1000 10 000 100 000 1 000 000 Capillary potential (kPa)
1.15 Capillary potential vs. relative water content with corresponding domains (Hall & Allinson, 2009a).
evaporating boundary, at which point equilibrium can be achieved between capillary water absorption and evaporative drying. Soluble salts in the absorbed water can be deposited in crystalline form at the surfaces where water evaporates; a process known as ‘efflorescence’.
1.3.5 Liquid flow In a fully saturated porous material the mean flow velocity, ux, of liquid water is proportional to the pressure gradient in the direction of flow, as defined by Darcy’s law. The pressure gradient is hydrostatic, the value of which is the difference in height (or static head) h1 – h2. Darcy’s law can therefore be written for flow velocity where:
u x = – k ∂h ∂x
1.39
The Darcy coefficient of permeability, k (m/s), is a constant within the formula and its value depends mainly upon (i) the pore structure of the material (e.g. porosity, tortuosity), and (ii) the properties of the permeating liquid such as viscosity and surface tension. Measurement of k is normally determined experimentally by measuring the steady-state flow rate of water through a saturated specimen under a static pressure differential. The apparatus is referred to as a permeability cell, and the test specimen is normally a circular
© Woodhead Publishing Limited, 2010
Heat and mass transport processes in building materials
37
disc, the sides of which are impermeably sealed to ensure uni-axial flow of the liquid. It is reasonable to consider the fluid (water) in this case to be incompressible and so the pressure gradient is linear, under steady state conditions. The intrinsic permeability, k, of a material is given by:
k=
kh rw
1.40
Note that this is distinct from the hydraulic conductivity of a material, K, which is measured in s/m. As with saturated specimens, liquid transport inside an unsaturated porous material is still governed by pressure differentials. The difference is that the mean pressure difference is negative, and hence is described as a ‘suction’ or more accurately as a capillary potential, Y. For unsaturated porous media the mean flow velocity, ux, can instead be written with a moisture-dependent coefficient of permeability (Hall & Yau, 1987):
u x = – K (q ) ∂Y ∂x
1.41
As previously discussed, a fully dried material can only exist after drying to constant mass at 105 °C, and a fully saturated material can normally only occur using vacuum saturation. We know that capillary domain water (entering VT in the liquid phase) is absorbed by the phenomenon known as capillarity. We also know that the transport of liquid water by capillarity occurs due to the pressure differential created by curvature of the absorbed water as a result of its dipole attraction to the void interior surfaces. However, by considering continuum-level absorption of liquid water into an entire complex network of interconnected voids (as in a real porous material), it is often helpful to consider the absorbed water as a bulk quantity. This means that the capillary potential of the pore network is reduced to a volume-averaged mean property. The volume-averaged Y, for example, results from the net contribution by every pore in the network; some will have smaller radii and higher Y values, others will have larger radii and lower Y values. Hence, when liquid water is absorbed by a porous material, the ‘sharp wet front’ (SWF) approximation is that the advancing wet front of the liquid can be represented by a rectangular cross-sectional profile, as shown by Fig. 1.16. SWF theory, in this sense, assumes that the porous material is semi infinite and that (if edge effects are ignored) the transport of water is one-dimensional (see Fig. 1.16). This is indeed appropriate in many cases where a material’s physical properties are being assessed, as in other similar cases such as the permeability cell described above. The SWF approximation also assumes that in the wetted region q = qc, and that this water content is uniform and constant. The wetting front itself has a hypothetical constant capillary
© Woodhead Publishing Limited, 2010
38
Materials for energy efficiency and thermal comfort in buildings P P0
P0
Yf x
0 xf
L
x f¢
A
1.16 Diagrammatic illustration of the sharp wet front analogy for absorption (adapted from Hall & Hoff, 2002).
potential, Yf, which differs from the capillary potential of the unsaturated region ahead by the amount Y – Yf. It can be appreciated from Fig. 1.16 that the one-dimensional absorption of water into the dry porous material (of length L) begins at the interface between a static water source and the material itself, at a time t = 0 and where x = 0 (Hall & Hoff, 2002). Note that the advancing wet front is located at xf = l(t) throughout the absorption process. The porous medium has an effective permeability coefficient, Ke and so the expression for mean flow velocity using Darcy’s law can be expressed as (Hall & Hoff, 2002):
Yf u = – K e dF = – K e dx L
1.42
Note that at x = 0 the total potential F = P0, where P is the hydrostatic fluid pressure. Also, at x = xf the total potential F = P0 + Yf. This gives a new expression for the cumulative volume of absorbed water per unit inflow surface area, i (mm3/mm2, or simply mm) as a function of elapsed time, t (min) (Hall & Hoff, 2002):
i = (2feKe |Y f |)0.5t0.5
1.43
The cumulative volume of absorbed water per unit inflow surface area (i) is first calculated thus:
i = Dw/Ar = St0.5
1.44
Since the sorptivity, S, is the linear regression slope of the straight line produced from i/t0.5, it follows that in the one-dimensional case S can also be expressed as:
i = (2f K Y )0.5 S = 0.5 e e f t © Woodhead Publishing Limited, 2010
1.45
Heat and mass transport processes in building materials
39
Note that many people use the term ‘water absorption coefficient’ in place of the sorptivity, as defined in EN ISO 15148, and it has the symbol Aw. In the case of absorption by capillarity, i can be determined using the relationship i = Dmw/Arw (Hall & Hoff, 2002; Hall & Kam-Ming, 1986). This can be measured (and the mathematical relationship validated) experimentally by the partial immersion test for porous materials. The test method is essentially a gravimetric determination of absorbed water, as a function of time, in a partially immersed porous material. The cumulative mass of absorbed water per unit inflow surface area increases linearly against the square root of elapsed time, referred to as the ‘linearity rule’. The sample rests on small stands in a tray of water, and is periodically weighed on a balance at certain elapsed time intervals (e.g. every minute) which involves interrupting the test for a brief period, normally less than 30 seconds. The wetted sample surface has to be wiped with a damp cloth to remove excess water that can present a degree of operator error and a potential drying effect depending upon the type, and moisture content, of the cloth. The testing procedure can be enhanced by maintaining a constant temperature of 20 °C (± 1°) in order to ensure more constant density and viscosity of the water. The depth to which the sample is partially immersed is 5 mm ± 1, which is neglected in the calculation for inflow surface area following the assumption of onedimensional liquid transport. For experimental control, however, the partial immersion depth can be adequately maintained by equipping the water-filled tray with a weir with constant overflow and a re-circulating pump (see Fig. 1.17). Viscosity, h, and surface tension, g, are inversely proportional when the linearity rule for partially-saturated flow applies such that (s/h)0.5 is proportional to S, and hence the chief motivational force in the sharp wet front model is the gradient of capillary potential.
Test specimen Constant head
Deionised water
Weir Tank 5 mm
Circulating pump
1.17 Apparatus for partial immersion test for water absorption.
© Woodhead Publishing Limited, 2010
40
Materials for energy efficiency and thermal comfort in buildings
1.3.6 Vapour diffusion In broad terms, diffusion is the redistribution of a quantity from an area of higher concentration to an area (or areas) of lower concentration. In terms of mass, which in the context of this chapter is water, diffusion applies to the redistribution of water vapour. The mean rate of water vapour diffusion is proportional to the concentration gradient in the direction of mass transport, as stated by Fick’s law of diffusion. This can be written as:
gv,air = – D
∂Cv ∂x
1.46
The coefficient of diffusivity (D) is a constant within the formula and its value depends mainly upon the pore structure of the material (e.g. porosity, tortuosity). Note the initial conditions at t = 0 when the mass concentration of water vapour, Cv (kg/m3), decreases across a distance x1 – x2. Since the water vapour concentration is essentially vapour density, it can be expressed in terms of its partial pressure (because it is mixed with air) using the ideal gas law to give:
Cv = rv =
pv M w RoT
1.47
where rv is density of water vapour (kg/m3), pv is partial pressure of water vapour (Pa), Mw is the molar mass of water (kg/kg mol), and Ro is the universal gas constant (J/kg mol K). We can transpose this term into the Fick’s law equation above to give:
gv,air = – D
M w ∂pv RoT ∂x
1.48
As the water vapour permeability of still air, da (kg/m s Pa), can be defined as:
da = D
Mw RoT
1.49
it follows that our equation for Fick’s law of diffusion, now specific to water vapour moving in still air, can be re-written as the partial differential:
gv,air = – d a
∂pv ∂x
1.50
Water vapour is, of course, absorbed by porous materials and so (from the moment it passes the threshold to enter VT) becomes hygroscopic water. It enters VT through pore openings at the surface of the material and is then
© Woodhead Publishing Limited, 2010
Heat and mass transport processes in building materials
41
able to migrate throughout the accessible pore network. Importantly, the fluid transport mechanism in porous materials is not defined simply by its domain classification. Once fluid has entered VT (i.e. been absorbed), the intrinsic conditions of the pore network will determine (i) fluid phase, and (ii) its associated transport mechanism(s). To elaborate on this, hygroscopic moisture (absorbed as vapour) will subsequently be adsorbed by internal surfaces, condense or diffuse. Capillary moisture (absorbed as liquid) will either flow or vaporise. The intrinsic properties that determine these conditions include pore radius, pore geometry, surface charge, and surface temperature. Therefore, absorbed water can change phase inside the pore network regardless of its domain. Note that the domain thresholds are always constant for a particular material. The complex spatial connectivity of the pore spaces increases path lengths, turbulence and flow restrictions (collectively known as ‘tortuosity’) and so providing additional resistance to vapour diffusion. The water vapour diffusion resistance factor, m, is used to quantify these effects and is calculated simply as the ratio between the vapour permeability of still air (see Eq. 1.49 above) and the vapour permeability of the material, dp (kg/m s Pa):
m=
da dp
1.51
The total rate of water vapour transfer through a porous material can therefore be calculated in one of two ways using:
gv = – d p
∂pv d ∂p =– a v ∂x m ∂x
1.52
The actual transport of water vapour, inside the complex pore network of a porous material, occurs by some or all of the following mechanisms: ∑ Fickian vapour diffusion through larger air-filled pores ∑ Knudsen diffusion through very small pores, and ∑ surface diffusion along the inner surface of all pores. For pores with very small radii, the mean molecular free path of the water vapour molecules can approach or even exceed the pore diameter itself. The ‘mean molecular free path’ is simply a mean distance over which a gas/ vapour-phase molecule will travel before (statistically) it has a collision with another gas/vapour-phase molecule of the same type (Bird et al., 2001). We know from the conservation laws that the total mass, energy and momentum before and after such a collision are the same. We can also recall that this is the fundamental mechanism by which molecular kinetic energy is transferred (in the form of heat) from the molecules at a higher energy state to those of a lower state, e.g. natural convection in a fluid. In the case of water vapour,
© Woodhead Publishing Limited, 2010
42
Materials for energy efficiency and thermal comfort in buildings
when the mean molecular free path is less than the diameter of the vessel in which it is contained (i.e. the pore), the molecules are statistically more likely to impact the pore walls than one another. The resulting collisions between pore walls and water molecules (dipolar) means that a particular process known as Knudsen diffusion dominates transport of water vapour within pores of this size (typically nanoscale). In addition, water vapour molecules (dipolar) that are adsorbed by pore walls, either in a single layer or as multiple layers, can migrate along the surface of the pore by a process called surface diffusion. The water vapour flow velocity through a porous material can be determined experimentally using the wet cup/dry cup method (BS EN ISO 12572, 2001), which must be conducted inside a temperature and relative humidity controlled environmental chamber (see Fig. 1.18). The base of the cup is filled with a small quantity of saturated salt solution. The test specimen is sealed in at the top of the cup suspended above the salt solution. The species of salt selected determines the saturation vapour pressure of the air above the solution, at known temperature, and hence controls the relative humidity, j, of that air. The constant values for j for a wide variety of different salts can be found in Kaye and Laby’s Tables of Physical and Chemical Constants (1995). The environmental chamber in which the test takes place may typically operate at 23 °C air temperature and 50% relative humidity. If the vapour pressure inside the cup produces a relative humidity higher than this, it is a ‘wet cup’ test (e.g. potassium nitrate solution, KNO3 94.0% RH at 23 °C) and the driving potential for diffusive vapour transport will be from the cup to the environmental chamber (through the specimen). Clearly under these Environmental chamber Desiccator
Fan
Continuous air flow Specimen
Seal Support
Specimen
Cup
Saturated salt solution (control)
Saturated salt solution (test)
1.18 Apparatus for water vapour permeability testing (taken from Hall & Allinson, 2009a).
© Woodhead Publishing Limited, 2010
Heat and mass transport processes in building materials
43
circumstances the moisture content of the specimen is greater than in the reverse situation of a ‘dry cup’ test. In this case the partial pressure inside the cup would be lower than ambient and water vapour transport is from the environment to the cup, hence the cup gains mass as opposed to losing mass in the wet cup test. The sides of test specimens must be sealed with epoxy resin to ensure uni-directional vapour transport through the specimen and to maintain constant inflow/outflow surface area. The absorbed mass of water (Dmw), in the case of a dry cup test, should increase linearly against the elapsed time (t). The slope of the straight line produced by Dmw/t gives the water vapour flow rate, G, through the specimen in kg/s. The water vapour permeance can then be calculated from: G 1.53 A · Dpv where A = specimen inflow surface area (m2), and Dpv = water vapour pressure difference across the specimen (Pa) which was calculated from the mean of the measured temperature and relative humidity over the course of the test. W =
1.3.7 Evaporation and drying In saturated or unsaturated porous materials, the process of drying occurs when the liquid water lost (by evaporation) at or near the surface is greater than the mass of water being stored or absorbed, i.e. when Dmw(t) is negative (Hall & Allinson, 2010). By referring to the sharp wet front (SWF) approximation discussed in Section 1.3.5, we can see that in the case of drying liquid water that is lost at (or near) the surface of the 1D semi-infinite material may be replaced by water moving from the interior flowing due to capillarity (Hall & Hoff, 2002). Obviously the phase change process results in evaporative cooling at or near the surface of the material which serves only to increase the gradient of capillary potential in this direction. The interface at which evaporative drying occurs can occur where x = xevap > 0 (i.e. still within the pore network). If this occurs, the water is transported from x = L to x = xevap by capillarity, and then from x = xevap to x = 0 by vapour diffusion, before finally leaving VT (i.e. desorption) (Hall & Hoff, 2002; Schaffer, 1932). The transport mechanism for desorption to the surrounding atmosphere is vapour diffusion augmented by natural convection. As water is being desorbed it is reasonable to assume that the partial pressure equals the saturation vapour pressure in the thin layer of air immediately adjacent to the surface, therefore we can say that j = 1 at the surface–fluid boundary. The volume (or quantity) of water being vaporised per unit surface area can be described as the evaporation flux, er, which can be quantified with reference to Fick’s law of diffusion (Hall & Hoff, 2002):
© Woodhead Publishing Limited, 2010
44
Materials for energy efficiency and thermal comfort in buildings
er = – rw Dw
∂p ∂cw = – rw Dv v ∂x ∂x
1.54
For the semi-infinite 1D porous material in Fig. 1.16, the sharp wet front (SWF) approximation was used in Section 1.3.5 to mathematically describe the advancing wet front of water as it was absorbed through the interface at x = 0 (Hall & Hoff, 2002; Hall & Allinson, 2009b). We assumed that as the wet front advanced towards x = L, the wetted region had an ‘effective’ relative moisture content that was uniformly ≤ qc. The cumulative volume of water per unit inflow surface area (i, mm3/mm2) increases linearly with the square root of elapsed time and can therefore be quantified as i = St0.5 (Hall and Hoff, 2002; Hall and Allinson, 2009b). If the source of water at the interface x = 0 is removed, evaporative drying immediately begins to occur as described by the processes above. Since this will result in q decreasing as a function of time, it is appropriate for us to use a term for the cumulative desorption per unit outflow surface area, id (mm3/mm2). Crucially, for absorption we know that Di is proportional to Dt0.5, and for desorption Did is also proportional to Dt0.5. The latter relationship allows us to create an opposite single term to sorptivity, and that is ‘desorptivity’, Sd (mm min–0.5) (Hall & Hoff, 2002) where:
id = t 0.5 Ú
q0
q1
f (q )dq = Sd t 0.5
1.55
As mentioned previously, the process of drying is essentially moisture lost from a porous material, where Dmw(t) < 0, which occurs by evaporation at or near the surface of VT. The mechanisms of drying can change as a function of time and so are normally characterised as being in one of two stages as discussed in the following sections. Stage 1 evaporative drying For Stage 1 drying to occur the material must have pore diameters that are sufficiently wide and/or continuous to allow gravitational water to exist. The rate of evaporative drying for gravitational pore water is the same as that for the surface of free (or unbound) water, e.g. from a Petri dish, under the same environmental conditions (Hall et al., 1984). Stage 1 is commonly referred to as the ‘constant drying rate’ process which exists where the evaporation flux, er @ constant. This is true but it may be even more accurate to state that the rate of Stage 1 drying, r1 is controlled by the ambient environmental conditions of partial vapour pressure and surface air flow velocity (Hall & Allinson, 2010). The reason for this distinction is because only if these environmental conditions are constant will the drying rate itself be constant, hence the need for the approximation symbol for evaporative flux above. The surface–fluid © Woodhead Publishing Limited, 2010
Heat and mass transport processes in building materials
45
boundary layer at x @ 0 is assumed constant and at saturation vapour pressure, which means that Fick’s law of diffusion can be used to quantify r1 where vapour diffusion across that boundary layer is considered:
M D Ê dp ˆ r1 = – rw Dv Á v ˜ = – rw w w dx RT Ë ¯
Ê dpv ˆ ÁË dx ˜¯
1.56
If we look more closely at what is happening, the thin layer of air in contact with the surface that we have termed ‘surface–fluid boundary layer’ can in fact be quantified as having finite thickness d. Within this layer, we already know that the partial pressure pv = psat at x = 0; however, we can add that pv decreases linearly with distance towards x = d which is known as the ‘far stream’ or outer edge of the surface–fluid boundary layer. This linear partial pressure gradient that occurs within the boundary layer can be accounted for by modifying Eq. 1.56 to give (Hall & Hoff, 2002):
r1 = rw
M w Dw Dpv RT d
1.57
Stage 2 evaporative drying Unlike Stage 1 drying which, as detailed in the previous section, requires the presence of gravitational water, Stage 2 drying only requires the presence of capillary water. That is to say, the porous material is ‘unsaturated and so its relative moisture content is between qr and qAEV. The Stage 2 drying rate is often referred to as the ‘falling drying rate’ because the evaporation flux, er, exceeds the mean flow velocity, u, of the water inside the porous material as it is transported towards xevap. Since the material is unsaturated, internal flow velocity of the liquid water is determined by the gradient of capillary potential, which is of course dependent on water content. As the material continues to dry, the internal flow velocity progressively decreases due to the falling gradient of capillary potential and so reducing the quantity of water being transported to xevap as a function of time (Hall & Allinson, 2010). We can therefore write an expression that allows us to quantify the Stage 2 rate of evaporative drying:
r2 =
did 1 –0.5 = t dt 2
q0
Úq
1
f (q )dq
1.58
Both the internal and surface capillary potentials are at zero when drying begins (at t = 0) because we have assumed uniform distribution of water. As evaporation proceeds there is a corresponding decrease in q due to evaporative loss thus creating a differential between the surface and internal capillary potentials, respectively. In experimental practice, establishing a
© Woodhead Publishing Limited, 2010
46
Materials for energy efficiency and thermal comfort in buildings
capillary potential (or vapour pressure) gradient is not instantaneous and so a short period of time (of varying length) may be anticipated until the system equilibrates and a constant flow velocity is approached. The transition from Stage 1 to Stage 2 drying occurs at the point when the water content equals the air entry value (AEV), qAEV. Above this critical point gravitational water can exist within the pores, and below this point the capillary potential is always sufficient to prevent free draining. On the pore water characterisation curve in Fig. 1.15, we can see hysteresis between the respective absorption and desorption values for the moisture-dependent capillary potential (or suction). This hysteresis occurs due to the combined effects of: ∑ ∑
differences between advancing and receding fluid contact angles, and the ‘ink bottle’ effect (continuous-pore radii variations).
We can therefore conclude that both the type (Stage 1 or 2) and rate of drying from a porous material can be determined from classification of the absorbed water. This can be illustrated using a hypothetical capillary tube of length l, where the maximum height of capillary rise hc is less than l. We can immediately see that when hc = l the relative water content equals qc. Since by definition qc ≤ qAEV, and evaporative loss occurs at the boundary x = hc, reduction in q occurs as a function of time through Stage 2 drying. If the hypothetical capillary tube is filled by capillarity until q = qc, and then filled from the top until q = qs, then Stage 1 evaporative drying begins at the boundary x = l (see Fig. 1.19). We can recall that this will mean the drying rate is constant during Stage 1. The transition to Stage 2 drying occurs when the reduced water content equals qAEV at which point the rate of drying begins to fall as a function of the gradient in capillary potential inside the capillary tube (Hall & Allinson, 2010).
1.4
Summary
To summarise, this chapter considers materials within the context of building physics that should enable the reader to appreciate how heat energy and mass (water vapour and liquid) can be absorbed, stored and released in relation to the building fabric. The fundamentals and driving potentials behind these processes have been discussed at length, which should enable an appreciation of the following facts regarding heat and mass transport phenomena: ∑ They occur simultaneously and are strongly inter-dependent. ∑ They cannot be treated in isolation from one another. ∑ They are essential in relation to the performance of the fabric of our buildings (energy efficiency, durability, weather tightness, etc.). ∑ They are essential for understanding the interaction between building fabric and occupied spaces, i.e. indoor environments.
© Woodhead Publishing Limited, 2010
Heat and mass transport processes in building materials 1D isothermal stage 1 drying
P Y S, P s
YI
0 Far stream
47
L
x=L
x=0
d
A 1D isothermal stage 2 drying
P
YI YS, P s L
Far stream
0
x=L
x=0
d
x = xevap A
1.19 Illustration of the sharp wet front analogy applied to Stage 1 and Stage 2 evaporative drying in porous materials (adapted from Hall & Hoff, 2002).
∑
They are essential for understanding conditions of indoor comfort and health.
1.5
Sources of further information
There is a vast array of information sources, databases, organisations and academic research communities working in different areas of this field. The following section provides directions and links for keen readers to find out more. The following offer membership, conferences, meetings and publications plus involvement in knowledge transfer networks and student sponsorship:
© Woodhead Publishing Limited, 2010
48
Materials for energy efficiency and thermal comfort in buildings
∑
The Chartered Institute of Building Services Engineers (CIBSE), 222 Balham High Road, London SW12 9BS. Tel +44 (0)20 8675 5211, Fax +44 (0)20 8675 5449. ∑ American Society of Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), 1791 Tullie Circle, N.E., Atlanta, GA 30329, USA. ∑ Institute of Materials, Minerals and Mining (IOM3), 1 Carlton House Terrace, London SW1Y 5DB. Tel: +44 (0)20 7451 7300, Fax: +44 (0)20 7839 1702.
Many leading international journals support the dissemination of high quality original research and are an excellent source for state-of-the-art knowledge, understanding and applications plus an awareness of active researchers and their particular specialism within the field. Recommended journals include: Building and Environment, Applied Thermal Engineering, Construction and Building Materials, Energy and Buildings, Journal of Building Physics and International Journal of Heat and Mass Transfer.
1.6
References
Asan H, 1998, ‘Effects of Wall’s Insulation Thickness and Position on Time Lag and Decrement Factor’, Energy and Buildings, 28, 299–305. ASHRAE, 2005, ASHRAE Handbook – Fundamentals, ASHRAE, Atlanta GA, USA. Atkins P & De Paula J, 2006, Atkins’ Physical Chemistry, 8th edn, Oxford University Press. Bird RB, Stewart WE & Lightfoot EN, 2001, Transport Phenomena, 2nd edn, Wiley. Bowles JE, 1984, Physical and Geotechnical Properties of Soils, 2nd edn, McGraw-Hill International Book Company. Bristow KL, 1998, ‘Measurement of thermal properties and water content of unsaturated sandy soil using dual-probe heat-pulse probes’, Agricultural and Forest Meteorology, 89, 75–84. BS EN ISO 8990, 1996, Thermal insulation – Determination of Steady-state Thermal Transmission Properties – Calibrated and guarded hot box, British Standards Institute, London. BS EN ISO 12572, 2001, Hygrothermal performance of building materials and products – Determination of water vapour transmission properties, British Standards Institute, London. BS EN 15026, 2007, Hygrothermal performance of building components and building elements. Assessment of moisture transfer by numerical simulation, British Standards Institute, London. CIBSE, 2006, Guide A – Environmental Design, 7th edn, Chartered Institute of Building Services Engineers, London. CIBSE, 2007, Guide C – Reference Data, Chartered Institute of Building Services Engineers, London. Cole RJ & Sturrock NS, 1977, ‘The convective heat exchange at the external surface of buildings’, Building and Environment, 12, 207–214.
© Woodhead Publishing Limited, 2010
Heat and mass transport processes in building materials
49
Doran S, 2000, ‘Field investigations of the thermal performance of construction elements as built’, Building Research Establishment Report #78132 – client report for DETR, Building Research Establishment, Garston. DTU, 2005, ‘Moisture buffering of building materials’, Report BYG-DTU R-126, Denmark Technical University. Energy Plus Engineering Reference Online, accessed March 2009, http://apps1.eere. energy.gov/buildings/energyplus/pdfs/engineeringreference.pdf Grimmond CSB, Potter SK, Zutter HN & Souch C, 2001, ‘Rapid methods to estimate sky-view factors applied to urban areas’, International Journal of Climatology, 21, 903–913. Hall C, 1977, ‘Water Movement in Porous Building Materials – I: Unsaturated Flow Theory and its Applications’, Building and Environment, 12, 117–125. Hall C & Hoff WD, 2002, Water Transport in Brick, Stone and Concrete, Taylor & Francis, London. Hall C & Kam-Ming T, 1986, ‘Water Movement in Porous Building Materials – VII: The Sorptivity of Mortars’, Building and Environment, 21, 113–118. Hall C & Yau MHR, 1987, ‘Water Movement in Porous Building Materials – IX: The Water Absorption and Sorptivity of Concretes’, Building and Environment, 22, 77–82. Hall C, Hoff WD & Nixon MR, 1984, ‘Water Movement in Porous Building Materials – VI: Evaporation and Drying in Brick and Block Materials’, Building and Environment, 19, 13–20. Hall M & Allinson D, 2008a, ‘Assessing the Effects of Soil Grading on the Moisture Content-Dependent Thermal Conductivity of Stabilised Rammed Earth Materials’, Applied Thermal Engineering, 29, 740– 747. Hall M & Allinson D, 2008b, ‘Assessing the Moisture Content-Dependent Parameters of Stabilised Earth Materials Using the Cyclic-Response Admittance Method’, Energy and Buildings, 40, 2044–2051. Hall M & Allinson D, 2009a, ‘Analysis of the Hygrothermal Functional Properties of Stabilised Rammed Earth Materials’, Building and Environment, 44, 1935–1942. Hall M & Allinson D, 2009b, ‘Influence of Cementicious Binder Content on Moisture Transport in Stabilised Earth Materials Analysed using 1-D Sharp Wet Front Theory’, Building and Environment, 44, 688–693. Hall M & Allinson D, 2010, ‘Analysis of evaporative drying in stabilised compressed earth materials using unsaturated flow theory’, Building and Environment, 45, 3, 509–518. Incropera FP, DeWitt DP, Bergman TL & Lavine AS, 2007, Fundamentals of heat and mass transfer, 6th edn, John Wiley & Sons. ISO 8301, 1991, Thermal insulation – Determination of Steady state thermal resistance and related properties – Heat flow meter apparatus, International Organization for Standardization, Geneva, Switzerland. ISO 10051, 1996, Thermal Insulation – Moisture Effects on Heat Transfer – Determination of Thermal Transmissivity of a Moist Material, International Organization for Standardization, Geneva, Switzerland. ISO 10456, 1999, Building materials and products: Procedures for determining declared and design thermal values, International Organization for Standardization, Geneva, Switzerland. Kaye GWC & Laby TH, 1995, Tables of Physical and Chemical Constants, 16th edn, available National Physics Laboratory Online. Künzel H, 1995, ‘Simultaneous heat and moisture transport in building components’, Report based on PhD thesis, Fraunhofer Institute of Building Physics, Germany. © Woodhead Publishing Limited, 2010
50
Materials for energy efficiency and thermal comfort in buildings
Liesen RJ & Pedersen CO, 1997, ‘An evaluation of inside surface heat balance models for use in a heat balance cooling load calculation procedure’, ASHRAE Transaction, 103, 485–502. McClellan TM & Pedersen CO, 1997, ‘Investigation of outside heat balance models for use in a heat balance cooling load calculation procedure’, ASHRAE Transaction, 103, 469–484. McMullan R, 1992, Environmental Science in buildings, 3rd edn, Macmillan Press, Hampshire. Pilkington B, Griffiths R, Goodhew S & de Wilde P, 2008, ‘Thermal Probe Technology for Buildings: Transition from Laboratory to Field Measurements’, J. Arch. Engrg, 14, 111–118. Rees SJ, Spitler JD, Davies MG & Haves PH, 2000, ‘Qualitative Comparison of North American and UK Cooling Load Calculation Methods’, International Journal of Heating, Ventilation, Air Conditioning and Refrigeration Research, 6, 75–99. Schaffer RJ, 1932, The Weathering of Natural Building Stones, HMSO, London. Valen MS, 1998, Moisture Transfer in Organic Coatings on Porous Materials – The Influence of Varying Environmental Conditions, PhD Thesis, Norwegian University of Science and Technology, Trondheim. Vos BH & Tammes E, 1968, Flow of water in the liquid phase, [report] Report no. B 1-68-38, Inst. TNO for Building Materials and building structures, Delft, Holland. Vos BH & Tammes E, 1969, Moisture and moisture transfer in porous materials, [report] Report no. BI-69-96, Organisation for industrial research TNO, Institute TNO for building materials and building structures, Delft, Holland.
1.7 A A s Bi C Cm c c cp c p* cs Cv D D w D v D s d e e r E
Appendix: Nomenclature area area of surface Biot number heat capacity molar heat capacity velocity of light (3.0 ¥ 108) specific heat capacity constant pressure specific heat capacity moisture content-dependent specific heat capacity wind speed mass concentration of water vapour diffusion coefficient for water vapour in still air molecular diffusivity of water molecular diffusivity of vapour hydraulic diffusivity thickness void ratio evaporation rate emissive power of a surface
© Woodhead Publishing Limited, 2010
m2 m2 – J/K J/mol K m/s J/kg K J/kg K J/kg K m/s kg/m3 m2/s m2/s m2/s m2/s m m3/m3 mm/s W/m2
Heat and mass transport processes in building materials
E b Ebl Fo f F g G gl g v gv,air H h h c h n h f he i i d K K k Kn L Lp m mf m w Mw n P P 0 Pa p v psat psat* Pw Q q qlat qsens
emissive power of a blackbody spectral emissive power of a blackbody fourier’s number decrement factor radiation view factor total rate of mass transfer water vapour flow rate rate of liquid water transfer rate of water vapour transfer rate of water vapour diffusion in still air enthalpy planck’s constant (6.63 ¥ 10–34) total (or mean) convection coefficient natural convection coefficient forced convection coefficient specific latent enthalpy of evaporation (or condensation) cumulative absorbed volume of water per unit inflow surface area cumulative desorbed volume of water per unit outflow surface area boltzmann’s constant (1.38 ¥ 10–23) hydraulic conductivity intrinsic (or specific) permeability Knudsen number effective length perimeter length mass moisture factor for thermal conductivity mass of water molar mass of water bulk porosity fluid pressure standard atmospheric pressure (barometric) total air pressure partial pressure of water vapour saturation vapour pressure saturation vapour pressure above a flat water surface total water pressure heat flow total heat flux latent heat flux sensible heat flux
© Woodhead Publishing Limited, 2010
51
W/m2 W/m2mm – – – kg/s m2 kg/s kg/s m2 kg/s m2 kg/s m2 J Js W/m2 K W/m2 K W/m2 K J/kg mm3/mm2 mm3/mm2 J/K s/m m2 – m m kg – kg kg/kg mol m3/m3 Pa Pa Pa Pa Pa Pa Pa W W/m2 W/m2 W/m2
52
Materials for energy efficiency and thermal comfort in buildings
r rs r1 r2 R R T R0 R v Rvap R f S S d S r t T u x U V V a V s V T V v v w w W Y – a a b g da dp e h q q80 qAEV qc qr qs qsurf
radius rate of evaporative drying of a flat water surface rate of stage 1 (constant rate) evaporative drying rate of stage 2 (falling rate) evaporative drying thermal resistance total thermal resistance universal gas constant resistance to water vapour transfer individual gas constant of water vapour roughness index sorptivity desorptivity degree of saturation (or saturation ratio) time thermodynamic temperature mass vector flow velocity thermal transmittance volume volume of air volume of solid state matter total volume of a specimen volume of void wind velocity specific moisture content water vapour permeance Thermal admittance angle absorptivity thermal diffusivity thermal effusivity surface tension water vapour permeability of still air water vapour permeability emissivity viscosity relative moisture content relative moisture content in equilibrium with 80% humidity air entry value relative moisture content capillary saturation relative moisture content hygroscopic limit of relative moisture content saturated relative moisture content relative moisture content at x = 0
© Woodhead Publishing Limited, 2010
m g/m2 h g/m2 h g/m2 h m2 K/W m2 K/W J/kg mol K m2 s Pa/kg J/kg K – mm/min0.5 mm/min0.5 m3/m3 s K m/s W/m2 K m3 m3 m3 m3 m3 m/s kg/m3 kg/m2 s Pa W/m2 K degrees – m2/s Ws0.5/m2 K N/m kg/m s Pa kg/m s Pa – Pa s – – – – – – –
Heat and mass transport processes in building materials
k l l l * lsolid lfluid l0fluid lrad lconv m x a x d r r rd rs rw r v r T rsi s t f j Y w v
Darcy’s coefficient of permeability wavelength dry state thermal conductivity moisture-dependant thermal conductivity thermal conductivity of a solid thermal conductivity of a fluid thermal conductivity of quiescent air effective conductivity due to radiation effective conductivity due to natural convection through a fluid water vapour diffusion resistance factor moisture capacity during absorption (from wetting curve) moisture capacity during desorption (from drying curve) reflectivity density dry density solid density density of water (assumed 1000 kg/m3 at 4 °C) density of water vapour total density solid density of each constituent in a composite Stefan–Boltzmann constant (5.669 ¥ 10–8) transmissivity thermal admittance time lag relative humidity capillary potential decrement factor time lag mass fraction of a constituent
© Woodhead Publishing Limited, 2010
m/s m W/m W/m W/m W/m W/m W/m W/m
53
K K K K K K K
– kg/kg kg/kg – kg/m3 kg/m3 kg/m3 kg/m3 kg/m3 kg/m3 kg/m3 W/m2 K4 – – – Pa – kg/kg
2
Hygrothermal behaviour and simulation in buildings
H. M. K ü n z e l, Fraunhofer Institute for Building Physics IBP, Germany and A. K a r agi o z i s, Oak Ridge National Laboratory, USA
Abstract: Energy efficiency and comfort are two new critical expectations of the modern building owner. With the recent technological advancement in all fields of engineering, buildings are also expected to be durable. Premature or accelerated ageing with the associated damage due to inappropriate design or operation is simply no longer acceptable. To prevent moisture-induced damage in buildings, hygrothermal simulation tools should be used to design envelope parts with good performance. The building envelope responds to the dynamic exterior and interior environmental loads. Temperature and humidity conditions in building structures must not exceed certain thresholds for effective moisture control. This has been recognized recently by a number of standards organizations in Europe and North America that deal with hygrothermal analysis. This chapter presents an overview of the fundamentals, the required material and construction input data, the required exterior and interior environmental loading, and the description of the output results from the heat and moisture transfer models. A few example cases are also presented that demonstrate how moisture problems may be investigated and how better design alternatives can become possible using hygrothermal analysis. Finally, the limits of the current state-of-the-art simulation models are described and futures trends and developments are discussed. Key words: hygrothermal analysis, moisture control, environmental loading, building envelope.
2.1
Introduction
Moisture control has become a worldwide issue because building operation and construction practices have been changing. The need to save energy has resulted in better insulated and airtight envelope systems which can become more sensitive to moisture problems than the traditional, poorly insulated constructions. Consumer demand for higher thermal comfort has increased the number of heating and air-conditioning systems installed in buildings. However, if the building envelope has not been designed to handle the higher thermal comfort requirements, under the recently imposed temperature and vapour pressure gradients, mould growth or condensation may occur. Appropriate moisture control design is a prerequisite for energy efficient and 54 © Woodhead Publishing Limited, 2010
Hygrothermal behaviour and simulation in buildings
55
damage-free new constructions as well as for the restoration or retrofit of traditional architecture. The right choice of moisture control measures for a particular building depends on a variety of parameters such as local climate conditions and construction traditions which differ from country to country, as well as constraints imposed by the architectural design and last but not least the available budget. It is almost impossible to establish general rules that apply everywhere. For this reason considerable scientific effort has been committed to the development of hygrothermal models that help to predict the transient temperature and humidity conditions in building envelope systems (walls, roofs and basements). Assessing the hygrothermal behaviour of traditional and modern buildings by applying hygrothermal models has become current standard practice (Karagiozis, 2001). This chapter deals with the exterior as well as the interior hygrothermal loads acting on constructions and the mathematical models that use these loads to simulate the response of the construction. Required input data such as material properties and boundary conditions are also described. The performance of hygrothermal simulation tools is demonstrated in comparison with experimental investigations. International standards and guidelines for moisture control are summarized and limitations of current models are discussed. Finally, future developments concerning moisture design with a safety factor are highlighted.
2.2
Hygrothermal loads
The main function of a building envelope is the protection of an enclosed space from the natural exterior environment. In Fig. 2.1 the hygrothermal loads acting on building envelope components are represented schematically for an external wall. Generally, temperature and humidity show considerable diurnal variations at the envelope’s exterior surface which are propagated only to a minor extent to the interior surface. During the daytime, the exterior surface heats up due to solar irradiation which leads to the evaporation of moisture from the surface layer. Around sunset when the short-wave solar radiation ceases, the long-wave (infrared) emission may lead to an overcooling (cooling down below ambient air temperature) of highly insulated wall systems and condensate may appear on the façade. The building envelope may also be exposed to wind-driven rain, which generally represents a more significant water load than exterior condensation. Groundwater is another frequent moisture load which may result in rising damp when water-proofing of the foundation is insufficient. Ambient temperature, relative humidity and partial vapour pressure form the permanent boundary conditions on both sides of the building envelope. The exterior conditions depend on the climate and the local environment. The indoor climate condition depends on the purpose and operation of the
© Woodhead Publishing Limited, 2010
56
Materials for energy efficiency and thermal comfort in buildings
Exterior
Solar radiation (direct & diffuse) Heat exchange with outdoor environment Wind-driven rain
Heat exchange with indoor environment
Vapour exchange with indoor air
Interior
Air pressure difference
Vapour exchange with outdoor air
Groundwater
2.1 Hygrothermal loads and their alternating diurnal or seasonal directions acting on the building envelope according to ASHRAE (2009).
building. Most buildings are controlled to keep the interior space comfortable for human beings and/or suitable for furnishings or artefacts. The resulting interior conditions represent an important hygrothermal load for the envelope that can be more severe than the exterior load especially when indoor moisture generation is high. For some specialized commercial constructions, libraries and museums, the temperature and humidity is controlled by HVAC (heating, ventilating and air conditioning) systems whose set-points are usually well defined. In many commercial and residential buildings the interior conditions are influenced by the behaviour of the occupants. In an average household up to 10 litres of water are evaporated every day. This moisture must be removed by ventilation or air-conditioning in order to assure comfortable and hygienic conditions. Often the operation of mechanical equipment (e.g. exhaust fans, fresh intake fans, recovery heat ventilators), or even leaky ducts due to improper workmanship, cause air pressure differentials which, in combination with stack and wind pressures, can significantly contribute to the moisture load, often more so than vapour diffusion. Another important moisture load, the so-called ‘initial construction moisture’ is often forgotten. In Europe building damage as a result of migrating construction moisture has become more frequent because tight construction schedules leave little time for building materials to dry out.
© Woodhead Publishing Limited, 2010
Hygrothermal behaviour and simulation in buildings
57
Construction moisture is either delivered with the building products or it is absorbed during the construction process. Cast-in-place concrete, autoclaved aerated concrete (AAC), and calcium silicate brick (CSB) are examples of materials that contain a lot of moisture when delivered. Unprotected wood kiln dried or even ‘green’ wood used predominately in North America and Scandinavian countries for framing, along with wood sheathing boards, can contain excessive amounts of moisture that if enclosed prematurely can do damage to the building construction (Karagiozis, 1998). Stucco, mortar, clay brick and concrete blocks are examples of materials that are either mixed or brought into contact with water at the construction site. All other porous building materials may take up precipitation or groundwater when left unprotected before the enclosure of the building. Vapour pressure differences within the envelope may cause moisture accumulation and drying at different locations. Air pressure difference along the face of the building and across the building envelope may assist in transport of moisture, which leads to either an accumulation or removal of moisture. Usually several hygrothermal load cycles are overlapping such as summer/winter, day/night and rain/sun. Therefore, a precise analysis of the expected loads should be carried out before designing a new building or changing the envelope of a traditional construction.
2.3
Modelling simultaneous heat and moisture transfer processes
In civil and architectural engineering, as well as for the purpose of heritage preservation, there is an increasing demand for calculative methods to assess and predict the long-term heat and moisture (hygrothermal) behaviour of building envelope systems. Controlling the temperature and humidity conditions in a particular wall or roof component is a critical task to prevent damage or premature ageing of building materials. The demand for better moisture control has been created by numerous moisture-related failures. Since there is no doubt that moisture transfer has an important influence on performance and service life of building components, the prediction of the hygrothermal behaviour becomes a prerequisite for damage-free and durable design. In the past these predictions were largely based on experiments, practical experience and simplified calculation tools, such as the steady-state dew-point method. Today there are a variety of transient calculation tools available (Trechsel, 2001) which provide reliable results if they meet certain specifications. These specifications have been laid down for the first time in the WTA Guideline 6-2 (2002) (WTA is the International Association for Science and Technology of Building Maintenance and Monuments Preservation). The German version of this guideline was issued in 2002 because existing
© Woodhead Publishing Limited, 2010
58
Materials for energy efficiency and thermal comfort in buildings
calculation methods were unable to predict the hygrothermal consequences of renovation measures or indoor climate changes in the case of traditional architecture. Given its international importance, an English version of this guideline was published only two years later. In the meantime the demand for hygrothermal simulation tools for design and forensic investigation purposes has increased considerably. As a consequence, a European Standard BS EN 15026 (2007) which is largely based on WTA Guideline 6-2 has been published. In order to comply with the requirements in BS EN 15026, transient hygrothermal simulation tools have to include the following transport and storage phenomena: ∑ ∑ ∑ ∑ ∑ ∑
heat storage of the dry building material and of the contained moisture heat transport by thermal conduction with moisture-dependent thermal conductivity latent heat transport by vapour diffusion with phase change (vapour evaporation/condensation) moisture storage by water vapour sorption and capillary forces water vapour transport by diffusion liquid transport by surface diffusion and capillary conduction.
As an example of the implementation of these hygrothermal phenomena, the differential equations employed for the well-established WUFI® model (Künzel, 1995; Karagiozis et al., 2001) are presented here: Moisture balance
∂w · ∂f = — · (D —f + d —(f p )) f p sat ∂f ∂t
2.1
Energy balance
∂H · ∂T = — · (l —T ) + h — · (d —(f p )) v p sat ∂T ∂t
2.2
where f is relative humidity, t is time, T is temperature, w is moisture content, psat is saturation vapor pressure, l is thermal conductivity, H is enthalpy, Df is liquid conduction coefficient, dp is vapour permeability and hv is latent heat of evaporation/condensation. The left-hand side of the moisture balance represents the moisture storage which is proportional to the derivative of the water retention curve (∂w/∂f). The transport terms on the right-hand side are described by the divergence of liquid and vapour flow. While vapour pressure (pv = f · psat), which is the driving force for vapour flow, depends strongly on temperature (saturation pressure psat ~ exp(T)), liquid flow is governed by capillary forces which are a function of relative humidity f only (Kelvin equation). The divergence
© Woodhead Publishing Limited, 2010
Hygrothermal behaviour and simulation in buildings
59
of vapour flow multiplied by the specific heat of evaporation represents the latent heat term on the right-hand side of the energy balance. The sensible heat flow is represented by the divergence of heat conduction. The storage term on the left-hand side of the energy equation – described as derivative of total enthalpy – contains the heat capacity of the dry material plus the enthalpy of absorbed water which depends on its state (solid, liquid or gaseous phase).
2.4
Input data for hygrothermal calculations
The execution of hygrothermal simulations including inputs and outputs is best described by a flow chart from prEN 15026 (2004) in Fig. 2.2. As first Hygrothermal material parameters & functions
Assembly, orientation & inclination of building component
Boundary condition surface transfer (indoor & outdoor climate)
Initial condition, calculation period, numerical control parameters
Input
Hygrothermal building envelope simulation
Output Water content, RH & moisture flux distributions & evolutions
Temperature & heat flux distributions & evolutions Post processing Energy consumption economy ecology
Biological growth rot, corrosion
Moisture related damage & degradation
2.2 Flow chart for hygrothermal simulations in prEN 15026 (2004). This chart has been dropped from the final version of this standard only because charts are discouraged due to additional efforts required for translation into the various European languages.
© Woodhead Publishing Limited, 2010
60
Materials for energy efficiency and thermal comfort in buildings
input, composition and exposure (orientation and inclination) of the building assembly under investigation are required. Then the material parameters for all construction layers have to be selected from a material database. The necessary material properties include: ∑ ∑ ∑ ∑ ∑
∑ ∑
Bulk density r in kg/m³, serves to convert the specific heat by mass to that by volume. Specific heat capacity c in J/(kg K). Thermal conductivity l in W/(m K) of the dry material and its moisturedependence. Porosity e in m³/m³, which determines the maximum water content wmax. Moisture storage, i.e. sorption res. suction isotherms w = f(f) in kg/m³ that give the equilibrium moisture content of materials as a function of relative humidity in both the hygroscopic and the capillary water (overhygroscopic) range. Vapour permeability in kg/(m² s Pa) which may depend on the ambient air humidity. Liquid diffusivity Dw in m²/s both for water uptake and redistribution res. drying of materials as a function of moisture content. Multiplying Dw by the derivative of the water retention curve gives the liquid conduction coefficient Df.
If present, liquid transport may dominate vapour diffusion by some orders of magnitude. Therefore it has to be considered carefully when liquid water has an impact on the building component, e.g. when wind-driven rain hits a cavity wall or a solid wall made of natural stone. In contrast to thermal conduction or vapour diffusion, liquid transport is highly non-linear because the diffusivity often shows an exponential increase with water content. As an example for typical liquid diffusivity functions of mineral building materials, the functions Dw = f(w) of calcium silicate brick (CSB) are plotted in Fig. 2.3. The liquid diffusivity used to simulate water absorption varies by a factor of almost 1000 between the equilibrium moisture content at 80% RH (w80) and the free water saturation (wf) of the material. Therefore liquid transport is very important when a porous material is wet while its influence decreases rapidly when the material dries out. After all materials and their hygrothermal properties in the investigated assembly are specified, the boundary conditions have to be selected. In order to obtain a realistic simulation of the hygrothermal performance of building components exposed to natural weather, the following climatic parameters should be provided: ∑ ∑
exterior air temperature exterior relative humidity
© Woodhead Publishing Limited, 2010
Hygrothermal behaviour and simulation in buildings
61
Liquid transport properties of CSB masonry units
10–6
Free (capillary) water saturation Wf Liquid diffusivity (m2/s)
W80 (water content at 80% RH) 10–7 Water absorption 10
–8
Drying, water redistribution
10–9
10–10 0
(2.5)
5
10 15 20 Water content (vol.–%)
25
(27.5)
30
2.3 From transient water absorption and redistribution measurements by NMR scanning, Krus (1996) approximated liquid diffusivity functions of calcium silicate brick (CSB) used for rainscreens or load bearing masonry. The diffusivity (separate functions are used for simulating water absorption and drying processes) depends exponentially (logarithmic scale of y-axis) on the water content of the material.
∑ ∑ ∑ ∑ ∑ ∑
short-wave radiation (global and diffuse solar radiation) long-wave radiation (thermal sky radiation) precipitation wind speed and direction interior air temperature interior relative humidity.
Hourly meteorological data sets are generally required owing to the diurnal changes of the exterior climate conditions. Depending on the purpose of the hygrothermal analysis, data from extreme years (BS EN 15026, 2007) may be more suitable than average meteorological data (e.g. test reference years) that are normally used for energy calculations. Since the interior climate shows less fluctuation, daily or even monthly mean data are sufficient for most applications. In many European countries indoor climate surveys of residential buildings have been carried out which lead to the development of representative indoor air conditions depending on the outdoor temperature (WTA 6-2; BS EN 15026). The impact of the exterior and interior climate conditions on the building envelope is also governed by the so-called surface transfer that describes the transport processes at the exterior and interior surfaces. Usually there
© Woodhead Publishing Limited, 2010
62
Materials for energy efficiency and thermal comfort in buildings
is a stagnant film of air at the surface which acts as a resistance to heat and vapour flow. This film resistance depends inversely on the air flow velocity at the surface and is therefore usually higher at the interior side of the building. The heat transfer coefficients often include the heat exchange by long-wave radiation which is sufficient for the interior surface but may lead to inaccurate results at the exterior side. In particular, when exterior condensation (and subsequent façade defacement due to algae and fungi) is an issue, an explicit radiation balance including long-wave radiation to the sky is required. The effect of solar radiation on the exterior surface is determined by the short-wave absorptivity as well as the long-wave emissivity of the surface layer. Recently, the impact of air cavity ventilation has been successfully integrated in hygrothermal models (see Künzel et al. (2008) and this type of air flow can allow a substantial amount of passive drying without mechanical equipment. The inclusion of this type of air flow in hygrothermal models has advanced the predictability of the design tools. The last input block in Fig. 2.2 contains the initial conditions and calculation specifications (duration, numerical accuracy, etc.). Since the temperature distribution over the building component normally adapts very quickly to the boundary conditions, a uniform temperature close to the expected mean can be selected as start value. Moisture transport processes are, however, comparatively slow. Therefore a realistic initial distribution may be important for the outcome of the simulation. If construction moisture is present it must be specified. For initially dry building materials, it is good practice to start with their equilibrium moisture content at 80% relative humidity. The new ANSI/ASHRAE Standard 160-2009 on ‘Criteria for MoistureControl Design Analysis in Buildings’ is aimed at providing guidance on how to best design buildings with adequate moisture control features. Given its mission, ASHRAE is uniquely qualified to provide such guidance. Computer simulation tools have become available and are used to predict the thermal and moisture conditions in buildings and the building envelope. These computer models are increasingly used to make recommendations for building design in various climates, and used as forensic tools in the investigation of building failures. However, results obtained with these models are extremely sensitive to the assumed moisture boundary conditions. Thus, a consistent approach to moisture design demands a consistent framework for design assumptions, or assumed ‘loads’. The ANSI/ASHRAE Standard 160-2009 formulates design assumptions for moisture design analysis and criteria for acceptable performance. As sufficient data are often not available to make a full statistical treatment practical, a moisture design protocol will have to be based on a combination of statistical data and professional judgement where only limited data exist. Damage is also another difficult area to address with high precision even with our state-of-the-art understanding. The standard has adopted the international consensus predicated on loads that will not be
© Woodhead Publishing Limited, 2010
Hygrothermal behaviour and simulation in buildings
63
exceeded 90% of the time. The standard uses a number of design indoor climate definitions that are based on engineering principles, independent of construction, and that include the impact of ventilation and air-conditioning equipment and controls that may or may not be part of the building design. The standard is flexible enough to encourage designers to use their own design parameter values if they are known. The standard includes default values for loads and parameters that are unknown. Appropriate measures are assumed to have been taken by the designer to limit bulk water entry into the building and building envelope. One major breakthrough has been to implement real loads in the design of wall systems. For example, the standard requires the design to include a 1% water penetration on the exterior side of the weather resistive barrier (building paper/membrane/sheet/liquid applied). This alone allows the design to examine the sensitivity to even small moisture loading, as a function of climate. ASTM E06 (2008) has concentrated on the development of a ‘Standard Guide for Documentation of Hygrothermal Models for Moisture Control Design in Building Envelopes’. Each hygrothermal model has specific capabilities and limitations. Determining the most appropriate hygrothermal model for a particular application requires a thorough analysis of the problem at hand, understanding the required transport processes involved, and available resources to conduct the analysis. Users of the standard can describe the functionality of the hygrothermal model used in an analysis in a consistent manner. This standard applies to hygrothermal models that range from complex research tools to simple design tools. A protocol for matching the analysis needs and the capabilities of candidate models is offered in this standard. This standard provides the needed characterization of the hygrothermal model to assess its credibility and suitability. This becomes even more important because of the increasing complexity of the building envelope systems for which new hygrothermal models are being developed. There are many different hygrothermal models available, each with specific capabilities, operational characteristics and limitations. If modelling is considered for a project, it is important to determine whether a hygrothermal model is appropriate for that project, or whether a model exists that can perform the simulations required in the project. This guide is intended to provide the framework for characterizing the functions of the hygrothermal model and the level of sophistication used as inputs for each analysis.
2.5
Hygrothermal calculation results
Hygrothermal simulation results shown in two output blocks in Fig. 2.2 consist of heat and moisture fluxes and transient cross-sectional distributions of temperature, relative humidity and water content. They may be presented as profiles for specific points in time or as temporal variations at a specific
© Woodhead Publishing Limited, 2010
64
Materials for energy efficiency and thermal comfort in buildings
location within the building component as shown in Fig. 2.4. A common presentation of the results is the stepwise visualization of the transient distributions in a movie-like fashion. Before the results can be analysed they should be checked for plausibility. This means all input and output data ought to be visualized in order to detect any inconsistencies. If possible the results should be compared to suitable experimental data. If the calculation results do not correspond to practical experience, the simulation should be repeated with different numerical grid sizes and/or time steps as well as modifications of key input parameters. If all data inspire confidence the next steps include analysis and interpretation of the resulting hygrothermal conditions within the building envelope systems. At first it should be checked that the resulting temperature, relative humidity or water content in the different materials do not exceed the limits specified for these materials. Then the annual moisture balance of the whole envelope system should be analysed. Building components containing some initial moisture should dry out. Continuous moisture accumulation is usually a sign of failure and calls for redesign of the component. However, these failure criteria may not be sufficient to ensure a good long-term performance of the building component. Therefore special post-process models would be helpful for satisfactory result interpretation. Figure 2.2 tentatively (blocks in grey) shows the need for tools that use the hygrothermal results as input data which are fed into another model whose output is translated into different performance criteria such as energy consumption, risk of corrosion, mould growth or rot. Another important aspect is material ageing which may alter the hygrothermal behaviour of building envelope systems altogether. Until now, only few post Moisture content variation of building component
ial init iour v a h be
l rma the m o r hyg ilibriu equ
Time
Temporal variation at location xp
Local distribution at time tp
RH RH
Time
Width
2.4 Examples for typical simulation result outputs. Temporal variations of the integral water content (left) and of temperature and relative humidity at a certain location within the component (middle). The same variables can also be plotted over the cross section of the component at a certain point in time (right).
© Woodhead Publishing Limited, 2010
Hygrothermal behaviour and simulation in buildings
65
process models have been developed and experimentally validated. Yet, with some expert knowledge it is still possible to predict the risk of failure of a particular building component without additional models, by comparing the hygrothermal behaviour of the investigated system with systems that have undergone experimental performance tests or have proven track records.
2.6
Model validation and practical applications
The validation of hygrothermal simulation models can be done in various ways. In order to make sure that model errors are not hidden by any uncertainties of input data or test results, a rigorous validation should comprise three steps. The first step has to be confirmation of correct implementation of physical fundamentals by comparison with analytical solutions. For moisture uptake in a semi-infinite region, there is a benchmark example in BS EN 15026 (2007). As second step it is useful to compare the calculation results to laboratory tests with well-defined boundary conditions and material data. The third step should be close to the real thing, e.g. simulating the transient hygrothermal behaviour of a building envelope component exposed to natural climate. It is important that all data of the component as well as the initial conditions be determined before starting the test. During the experiment boundary conditions as well as temperature and humidity fluctuations at predefined locations in the building component should be recorded carefully. If simulation and experimental results agree well the model validation for the selected envelope component was successful. This does not mean that the model will provide accurate predictions for all kinds of building components and boundary conditions. But it can be expected that simulation results are close to reality if building component and climatic loads are similar to the validation case. Due to increasing practical applications of hygrothermal simulation models, numerous validation cases have already been reported from which two examples are chosen, a flat roof and a natural stone façade.
2.6.1 Hygrothermal conditions in a flat roof At the field test site of the Fraunhofer Institute for Building Physics (IBP) in Holzkirchen, a 40 m² lightweight flat roof was erected. The load bearing structure of the roof is sealed with an aluminium vapour barrier. The insulation layer on top of the vapour barrier consists of high density glass fibre boards (90 mm) which is covered by a dark coloured impermeable roofing membrane. The aim of the study was to determine the hygrothermal loads caused by water trapped between vapour barrier and roofing membrane, as the fibre glass boards were spray wetted before closing up the roof. For a period of one year the temperature and humidity conditions at different locations in the insulation layer were measured (Fig. 2.5). The indoor conditions were
© Woodhead Publishing Limited, 2010
66
Materials for energy efficiency and thermal comfort in buildings
1
2
3
4
Assembly from inside to outside: 1 2 3 4
Wooden sheathing Vapour barrier Glass wool Roofing felt (bitumen) Position of sensors
2.5 Cross section of the flat roof with temperature and humidity sensor positions.
Temperature (°C)
80
Summer
Winter
60 40 20 0 –20
Rel. humidity (%)
100 80 60 40 Measurement Calculation
20 0 15.8
21.8 15.12
21.12
2.6 Comparison of measured and calculated temperature and humidity variations at the exterior sensor position in the roof for two selected weeks in August and December.
kept at room temperature while an on-site meteorological station recorded all necessary weather data. After closing the roof, good weather conditions resulted in large temperature and humidity fluctuations at the top of the insulation layer beneath the roofing membrane. Figure 2.6 plots these results for a period of one week in August. While the roof surface temperature can exceed 60 °C during daytime, it drops to 0 °C during the night. The steep temperature changes result in even higher changes in vapour pressure beneath the roofing membrane (saturation vapour pressure increases exponentially with temperature) which drives the
© Woodhead Publishing Limited, 2010
Hygrothermal behaviour and simulation in buildings
67
moisture up and down in diurnal cycles. When the sun heats up the roof, the humidity at the top of the insulation layer drops to 20% RH. In the evening the vapour flow inverses and condensation occurs on the inner side of the roofing membrane (RH = 100%). In winter the roof surface temperature is too low to drive the moisture towards the interior. Therefore, the relative humidity below the roofing membrane will remain at 100% all day long (Fig. 2.6, right). Comparison of the measured and simulated temperature and humidity conditions show excellent agreement in all graphs, as depicted in Fig. 2.6. The simulations included the use of the actual weather data from the on-site meteorological station and long-wave radiation to the sky was also used. This explains why the calculation model is able to capture the overcooling of the roof’s surface by approximately 5–8 K below ambient air temperature in August. The deviations in measured and simulated surface temperature during the last three days of the observation period in winter can be explained by the effect of snowfall during the night of 18 December. The snow cover prevented a rise in roof surface temperature above 0 °C until it had melted away two days later. The simulation cannot capture this effect because the recorded precipitation data do not differentiate between rain and snow (standard rain gauges are heated to ensure snow melt for accurate droplet counter and tipping bucket measurement). The durability of building materials is often adversely affected by the coincidence of high temperature and humidity conditions, as can be found for the glass fibre insulation located in the flat roof. For accurate assessment of its service life the maximum temperature and humidity occurring at the same time play an important part. Therefore the coinciding temperature and relative humidity conditions recorded from August until January at the different sensor positions in the insulation layer of the roof has been plotted in Fig. 2.7. Again almost no difference is found between measured and calculated results. Regarding the three sensor locations, the worst scenario occurs at the exterior (top) side of the insulation layer directly under the roofing membrane. The dashed line in the three graphs represents the maximum limit for temperature and humidity coincidence in the whole insulation layer. The line clearly shows a significant decrease in humidity when a temperature of 40 °C is exceeded. When temperatures rise above 60 °C at a certain location in the roof, the humidity drops to less than 50% RH. The humidity decreases at the same time as the temperature rises, which can clearly be observed by looking at the diurnal fluctuations of temperature and humidity beneath the roofing membrane in summer (Fig. 2.6). Investigations such as this help to select appropriate temperature and humidity conditions for durability tests in the laboratory. Since extensive tests on real objects are expensive, hygrothermal simulation models can be very helpful once they have been validated for the specific building application. They can also be employed to study the influence of hot and humid climate
© Woodhead Publishing Limited, 2010
68
Materials for energy efficiency and thermal comfort in buildings
Exterior
Interjacent
Interior
Rel. humidity (%)
100 80 60 40 Measurement Calculation
20 0 – 20 0
20 40 60 80 –20 0 20 40 60 80 –20 0 20 40 60 80 Temperature Temperature Temperature
2.7 Coinciding temperature and humidity conditions on an hourly basis measured and calculated at three sensor positions. The dashed line represents the upper limit for the hygrothermal load within the insulation layer of the roof.
zones on building envelope performance since most practical experience has been obtained by trial-and-error in the moderate climate zones of Europe and North America. This allows construction materials to be tested before being used for building envelope components subject to operating conditions they have not been designed for.
2.6.2 Moisture behaviour of natural stone façade To develop better means to preserve heritage buildings such as castles and churches, the moisture behaviour and related degradation processes of natural stone have to be analysed. In the frame of a comprehensive project the hygrothermal properties of several species of natural stone were determined as a basis for numerical simulations. Parallel to investigations in the laboratory, a field test was carried out exposing stone samples at one side to natural weather and at the other side to a well-defined interior climate. The detailed recordings of the boundary conditions on both sides of the stone samples also served as input data for the hygrothermal simulations. During the field test the natural stone samples which formed part of a wall were periodically removed and weighed to determine their water content. In addition the samples were scanned from time to time by a nuclear magnetic resonance (NMR) apparatus in order to obtain an instant moisture distribution profile over the cross section of the façade. A comparison of experimental results with hygrothermal simulation results is presented in Fig. 2.8. The top graph shows the total water content variations of three samples of the same natural stone species (Sander sandstone) compared to the calculated curve. The steep increases in water content at several occasions during the observation period are the result of driving rain events which, interrupted by bright spells, result in a slow moisture accumulation of the originally
© Woodhead Publishing Limited, 2010
Hygrothermal behaviour and simulation in buildings
69
Total water content (kg/m3)
40 Measurement: Sample 1 Sample 2 Sample 3
30
Calculation
20
10
0
0
10
20
30 40 50 Observation time (d)
60
70
80
(a) Bright spell
Rainy weather
12.5
Local water content (vol-%)
Calculation NMR-Scans 10.5
7.5
5.0
2.5
0.0 0
5
10
15
20 25 0 5 Wall cross-section (cm)
10
15
20
25
(b)
2.8 (a) Temporal variations of the integral water content of the exposed natural stone samples determined by weighing in comparison with simulation results. (b) Moisture distributions in the samples determined by NMR scanning at two points in time compared to simulated moisture profiles for the same dates.
dry samples. Figure 2.8(b) presents a comparison of the measured and calculated moisture distributions over the cross section of the natural stone wall (the samples are part of the wall) for two distinct points in time. The presented temporal variations as well as the moisture distributions show an excellent agreement between hygrothermal simulation and experiment, which proves that the hygrothermal model describes the moisture behaviour of exposed natural stone walls accurately. It should be noted, however, that these results are based on a detailed analysis of the hygrothermal properties in the laboratory and on-site registration of the interior and exterior climate
© Woodhead Publishing Limited, 2010
70
Materials for energy efficiency and thermal comfort in buildings
conditions including hourly measurements of the driving rain load by a rain gauge integrated in the test façade. Additionally, natural stone represents an ideal material concerning homogeneity and variability which means the hygrothermal properties show little or no variation with location and time. The comparison with the experiment inspires confidence in the simulation results. Since walls of heritage buildings are usually thicker than the wall in the field test (25 cm), the simulations were repeated with the same material properties of Sander sandstone and with a typical meteorological dataset for a wall of 60 cm thickness. The aim of this study was to get an average moisture and temperature distribution in such a wall as a basis for further analysis of degradation processes and remedial measures. Therefore the simulations were run with the same annual climate conditions until a dynamic equilibrium was achieved. The dynamic equilibrium is the condition most likely to be found in existing buildings with continuous operation. It means that heat and moisture gains or losses of a building envelope component integrated over one year are zero. In principle this can only be attained when the same meteorological dataset is applied. Since problems often occur at walls exposed to wind-driven rain, a western orientation has been selected. The results are plotted in Fig. 2.9 as annual variations and mean profiles of temperature and water content. Due to the dark beige colour of the sandstone, the maximum surface temperature in summer may exceed 40 °C. The lowest temperature coincides with the minimum air temperature in winter. Towards the interior of the building the temperature variations are gradually dampened and the annual mean profile (solid line in Fig. 2.9(a)) forms a straight line between the average exterior and interior conditions which can be expected because heat transfer is described by a linear differential equation. However, the picture changes when the moisture distributions in Fig. 2.9(b) are analysed. First of all, the annual variations in moisture content due to natural weather do not reach the interior side of the wall; in fact the climatic influence does not go beyond the exterior third of the wall. Even more surprising is the shape of the annual variation range and the mean distribution which do not form a straight line. Similar to the thermal pro cesses, the fluctuations in water content due to direct impact of hygrothermal load cycles (wind-driven rain/solar radiation) peak at the exterior surface. However, the average water content at the surface lies below 3 vol.-% which is almost the same as at the interior surface. Some millimetres beneath the exterior surface, the average water content rises steeply and reaches a maximum of approx. 7 vol.-% at a depth of about 5 cm. This phenomenon is caused by the strong – non-linear – dependence of liquid transport on water content which has already been discussed by referring to the liquid diffusivity functions in Fig. 2.3. The practical consequences of this moisture behaviour for porous materials
© Woodhead Publishing Limited, 2010
Hygrothermal behaviour and simulation in buildings
71
Temperature (°C)
60
40
20
0
–20
(a)
Temperature (°C)
16
12
8
4
0
0
10
20 30 40 Wall cross section (cm)
50
60
(b)
2.9 Annual variations (shaded areas) and mean profiles (solid lines) of temperature and moisture content in an external wall made of Sander sandstone. These results are obtained by running the simulations with the same meteorological dataset of one year until a dynamic equilibrium is reached, i.e. the mean profiles do not change from one year to the next.
exposed to wind-driven rain are manifold. Material degradation is often caused by dilatation processes in the microstructure due to the expansion of freezing water or crystallizing salts. Especially in the case of frost, the risk of damage increases with water content. This would explain why the material layer beneath the surface is often more degraded than the exposed surface layer, which may lead to spalling or delamination of the exterior crusts. There are also positive aspects. Rainwater hitting the surface is absorbed and stored in a layer some distance beneath the surface which is not accessible to microorganisms. Stored rainwater in concrete façades prevents carbon dioxide diffusion and therefore protects the layer with the reinforcing steel from carbonation and consequently the steel from corrosion.
© Woodhead Publishing Limited, 2010
72
Materials for energy efficiency and thermal comfort in buildings
As an example for a two-dimensional calculation, the moisture distribution in an exposed natural stone wall with poured mortar joints is investigated. Poured mortar is often used between big blocks of natural stone which would unevenly compress normal mortar due to their weight. Therefore, gauges are used to produce a gap between two blocks and a mortar with low viscosity is poured in between. Once hardened the mortar is rather porous and its water absorption capacity (liquid diffusivity) as well as its vapour permeability are much higher than those of the natural stone blocks. This may cause damage of the stone blocks starting at the interface with the mortar joint, as demonstrated by a photograph of an exposed part of the cathedral in Cologne (Fig. 2.10(c)). The simulated moisture distribution in a wall section with a mortar joint between two differently orientated anisotropic sandstones (inherent structure results in directionally different water absorption) is presented in Fig. 2.10(a). The resulting isohygric zones (zones with identical water content) after three hours of intensive wind-driven rain show the rapid water absorption of the mortar joint. Its comparatively high liquid diffusivity facilitates the water infiltration while the adjacent stone blocks lag behind. However, in the vicinity of the joints the initially dry sandstone blocks extract water from the mortar. In particular, the vertically layered block seems to draw a considerable amount of moisture from the joint. This becomes even more evident by looking at the resulting moisture distributions after another 48 hours of dry weather presented in Fig. 2.10(b). 3 hours of driving rain
48 hours of dry weather
Sandstone (vertically layered)
Mortar joint
Sandstone (horizontally layered)
(a)
(b)
(c)
2.10 Moisture distribution in a wall section made of anisotropic natural sandstone blocks and poured mortar joints after 3 hours of intensive rain (a) and after another 48 hours of dry weather (b) simulated with WUFI®-2D. The zones of elevated residual moisture close to the mortar joint may explain the mechanism leading to the observed damage case at the cathedral of Cologne (c).
© Woodhead Publishing Limited, 2010
Hygrothermal behaviour and simulation in buildings
73
The mortar joint is now drier than the stone blocks next to it because of the high vapour permeability of the mortar. The residual moisture maxima in the sandstone blocks are again located beneath the exterior surface. But now there is an additional zone of elevated moisture next to the mortar joint. This phenomenon helps to explain why the sandstone degradation observed at Cologne cathedral appears to start at the mortar joints.
2.7
Limitations of current hygrothermal models
While there has been a considerable amount of progress in developing hygrothermal models for the architect or building envelope designer, a number of overall limitations may still be present. First, mainstream commercial hygrothermal models are based on deterministic, rather than statistical distribution of the material properties and loads (Salonvaara et al., 2001). Most of the available hygrothermal models are implemented in one dimension and do not include air flow through the envelope structure. Being one dimensional precludes the transport phenomena associated with groundwater, hydrostatic pressures and gravity. Air flow is not yet captured by most hygrothermal models, with the exception of air cavity ventilation. However, research is on-going that aims at specifying the moisture sources which result from humid air infiltration into building envelope components. Currently hygrothermal models do not include the impact of ageing, material properties that change with respect to time or cumulative damage. Dimensional changes such as swelling and shrinkage, the eventual cracking of the material, and loss of mass are not accounted for in the current versions of the models. Indeed all material properties are considered constant in time. The loads due to wind-driven rain are also crudely approximated with very simple expressions that do not take into account the interference of other buildings or architectural details and the geometry of the building. While these limitations exist in most design applications, the user is interested in performance ranges, for example, does a particular wall system perform better with a vapour tight or vapour open weather resistive barrier? Is adding insulation beneficial for moisture control, and if so which type of insulation? These answers can be readily addressed by the current hygrothermal models.
2.8
Conclusions and future trends
In recent years, hygrothermal simulation models have become useful tools for moisture control design of new and existing buildings. This includes the moisture analysis of walls and roofs of heritage constructions that must be handled with special care when restoration or retrofit measures are envisaged. These tools have been successfully employed to predict the hygrothermal
© Woodhead Publishing Limited, 2010
74
Materials for energy efficiency and thermal comfort in buildings
performance of building materials and envelope systems under different indoor and outdoor climate conditions. There are even some examples where hygrothermal simulations have resulted in the development of innovative solutions for better building enclosures, e.g. a humidity controlled vapour retarder (Künzel 1998) for wooden wall and roof constructions. There are a number of ways moisture can enter the building enclosure. Interstitial condensation due to vapour diffusion – which has been dealt with extensively in the past – is hardly the most important one. In fact, the most important and unexpected damage cases of the last decade were all caused by leaky windows or problematic flashings that introduced rainwater penetration and harmful code vapour retarder requirements. An example were the problems with exterior wall insulation systems (EIFS) in North America (Cheple & Huelman 2000) and the current trouble with EIFS for Scandinavia. (Samuelson et al., 2008). Equally important may be moisture intrusion as a result of air flow in lightweight wood frame construction, as well as commercial metal frame construction. Infiltration of humid air into a building component due to total pressure differences amplifies the effect of vapour diffusion. Air pressures created by the direct wind or adjacent environment (other buildings, stack effect due to buoyancy forces and mechanical pressures due to the operation of equipment) can create positive or negative flows across different parts of the building. Moisture may be accumulating at one part of the building while drying at another part due to infiltrating or exfiltrating air flows. An adequate drying potential towards both sides of the building component is therefore extremely beneficial for the reduction of moisture damage risks. Hygrothermal simulations offer the opportunity to find the most effective solution between two opposing tasks: to prevent or at least limit the moisture entry into a building component and to let moisture that has entered dry out again as fast as possible. Design optimizations that result in more moisture tolerant constructions are already encouraged by the European Standard EN 15026 (2007) and even more importantly by the recently issued ANSI/ ASHRAE Standard 160-2009. Last but not least there is also a working group at ASTM which will issue a new Standard on hygrothermal simulation models in the near future. From a practical point of view there is still a lack of post-processing models that will translate the hygrothermal simulation results into pass/fail criteria or into a service life prediction. This is a scientific challenge for everybody involved in damage prevention. Most degradation processes in the construction sector are somehow related to moisture and temperature, such as: ∑ ∑
chemical reactions like corrosion or hydration biological processes like rot, mould growth and algae formation
© Woodhead Publishing Limited, 2010
Hygrothermal behaviour and simulation in buildings
∑ ∑
75
physical damage of the microstructure due to frost or salt crystallization shape changes or warping due to hygrothermal dilatation.
This list is far from complete and yet there are only very few criteria that establish a quantitative correlation between the hygrothermal conditions and the durability of building materials and components. One reason is that durability itself is difficult to define. In the context of hygrothermics it means a low risk of damage and a known progress of degradation until a limit state is reached where maintenance or replacement is required. Another reason is the lack of specific knowledge concerning hygrothermal degradation processes. However, performing hygrothermal simulations is the first step towards a better solution. Therefore more scientists should be encouraged to get involved in this subject.
2.9
References
ANSI/ASHRAE (2009) Standard 160-2009 Criteria for Moisture Control Design Analysis in Buildings. ASHRAE (2009) Handbook of Fundamentals, chapter 25 ‘heat, air and moisture control in building assemblies – fundamentals’. ASTM E06.41 (2008) Standard Guide for Documentation of Hygrothermal Models for Moisture Control Design in Building Envelopes, Sept. BS EN 15026 (2007) Hygrothermal performance of building components and building elements – Assessment of moisture transfer by numerical simulation. April. Cheple, M. and Huelman, P. (2000) Literature Review of Exterior Insulation Finish Sys tems and Stucco Finishes. Report MNDC/RP B80-0130, University of Minnesota. Karagiozis, A.N. (1998) Applied Moisture Engineering, Thermal Performance of the Exterior Envelopes of Building VII. Clearwater Beach, FL, ASHRAE Proceedings; pp. 239–251, December 6–10 1998. Karagiozis, A.N. (2001) Advanced Hygrothermal Models and Design Models. The Canadian Conference on Building Simulation, Ottawa, International Building Performance Simulation Association (IBPSA), pp. 547–554, 13–14 June. Karagiozis, A.N., Künzel H.M. and Holm A. (2001) WUFI-ORNL/IBP – A North American Hygrothermal Model. Performance of Exterior Envelopes of Whole Buildings VIII: Integration of Building Envelopes, 2–7 December. Krus, M. (1996) Moisture Transport and Storage Coefficients of Porous Mineral Building Materials – Theoretical Principles and New Test Methods. IRB-Verlag, Stuttgart. Künzel H.M. (1995) Simultaneous Heat and Moisture Transport in Building Components – One-and two-dimensional calculation using simple parameters. http://publica. fraunhofer.de/eprints/urn:nbn:de:0011-px-566563.pdf. Künzel, H.M. (1998) The Smart Vapor Retarder: An Innovation Inspired by Computer Simulations. ASHRAE Transactions 104/2, 903–907. Künzel, H.M., Karagiozis, A. and Kehrer, M. (2008) Assessing the benefits of cavity ventilation by hygrothermal simulation. Proceedings Building Physics Symposium, Leuven, pp. 17–20. prEn 15026 (2004) Hygrothermal performance of building components and building elements – Assessment of moisture transfer by numerical simulation. August. © Woodhead Publishing Limited, 2010
76
Materials for energy efficiency and thermal comfort in buildings
Salonvaara, M., Karagiozis, A. and Holm, A. (2001) Stochastic Building Envelope Modeling – The Influence of Material Properties. Performance of Exterior Envelopes of Whole Buildings VIII: Integration of Building Envelopes, 2–7 December. Samuelson, I., Mjörnell, K. and Jansson, A. (2008) Moisture damage in rendered, undrained, well insulated stud walls. Proc. 8th Symposium of Building Physics in the Nordic Countries, Copenhagen, 1253–1260. Trechsel, H.R. (2001) Moisture Analysis and Condensation Control in Building Envelopes. American Society for Testing and Materials (ASTM) Manual 40. WTA (2002) Merkblatt 6-2-01: Simulation of Heat and Moisture Transfer, May. English version Oct. 2004. WTA-Publications, www.wta.de.
© Woodhead Publishing Limited, 2010
3
Ventilation, air quality and airtightness in buildings D. W. E t h e r i d g e, University of Nottingham, UK
Abstract: This chapter gives an overview of ventilation and air quality in low-energy buildings, leading to a description of how materials can influence the performance of ventilation systems. Emphasis is placed on natural ventilation, since, in principle, it offers a passive low-energy solution. Potentially important contributions from materials relate to the control of envelope leakage, thermal storage with phase-change materials, ‘smart’ glazing for controlling solar gains and, possibly, porous materials for insulation and night cooling. Key words: natural ventilation, building design, low-energy ventilation, phase-change materials, air quality.
3.1
Introduction
The primary purpose of a ventilation system is to contribute to the provision of a safe, healthy and comfortable indoor environment. Nowadays, this purpose needs to be satisfied with minimal energy consumption, i.e. the systems should be ‘low-energy’. The aims of this chapter are to give an overview of building ventilation systems and to describe areas where materials can play a role in the development of low-energy systems. Thus Section 3.2 describes the basic types of system (natural and mechanical) and what constitutes a low-energy system. Section 3.3 explains the main physical mechanisms involved. In principle, natural ventilation offers a passive low-energy solution and therefore Sections 3.4 and 3.5 deal respectively with the feasibility and the design of natural ventilation systems. It is here that some important roles of materials are introduced. These aspects are then dealt with in more detail in Section 3.6 for both natural and mechanical systems. The emphasis is on buildings where the occupants are the determinants of ventilation rates, e.g. commercial buildings and dwellings, rather than industrial buildings.
3.2
Ventilation systems
3.2.1 Types of system There are basically two types of ventilation system, namely natural and 77 © Woodhead Publishing Limited, 2010
78
Materials for energy efficiency and thermal comfort in buildings
mechanical. A pure natural ventilation system is one where the ventilation arises from flows through openings in the envelope, which are generated by the natural forces due to wind and buoyancy (gravity). The envelope is the fabric that encloses the air, e.g. external and internal walls. Natural ventilation has of course been the sole means of ventilation for thousands of years in all climates. The underlying aim of modern design is to improve and adapt systems to cope with changing circumstances (climate change and the desire for low-energy buildings). Another aim is to expand the application of natural ventilation to non-domestic buildings where mechanical ventilation is usually adopted. A pure mechanical ventilation system is one where the ventilation is provided by a network of ducts, powered by a fan or fans. Mechanical ventilation is a relatively recent phenomenon, which is suited to the particular demands of large non-domestic buildings. However, in some countries mechanical ventilation in dwellings is not uncommon, particularly for multi-family apartments. Modern design of mechanical systems has the same underlying aim as for natural systems. There are three basic types of mechanical system: ∑
Extract only – the air is extracted through ducts, with openings in the envelope providing the route for air supply. ∑ Supply only – air is supplied through the ducts, and openings in the envelope provide the exhaust route. ∑ Supply and extract system – separate duct networks perform the supply and extract functions, which, if the mass flow rates are equal, is referred to as a balanced system. Not surprisingly, there are variants of the above. For example, a building that is primarily naturally ventilated may have local mechanical ventilation devices, e.g. extract fans in some rooms, cooker hoods, desk fans. Systems that combine natural and mechanical ventilation in some way are known as mixed-mode systems (the terms hybrid and assisted natural are also used). A relevant example is where both natural and mechanical systems are installed, but the mechanical system is used only when the natural system is (or is believed to be) insufficient. This is known as a complementary or changeover mixed-mode system.
3.2.2 Differences between systems Mechanical systems offer close control over the magnitude and direction of the flow rates of air into a space and over the positions where the air enters and leaves. With natural ventilation, the positions of openings in the envelope form part of the design, but the magnitude and direction of the flow rates can vary widely with time. A specific aim of natural ventilation
© Woodhead Publishing Limited, 2010
Ventilation, air quality and airtightness in buildings
79
design is to build in some element of control, particularly with respect to flow directions (Section 3.5). The high level of control with mechanical systems stems from the use of fans for driving air through ducts. This advantage comes at a financial cost, namely higher capital and maintenance costs. Moreover, with long duct lengths and high flow rates, the electrical energy consumed by the fans can be significant. However, with a balanced system, heat recovery from ventilation air can more than compensate for this. Another important difference is that a mechanical ventilation system can be used to distribute treated air, i.e. heated, cooled and/or dehumidified air (air conditioning system). In such systems, high flow rates are usually required and the provision of fresh air is a relatively minor function of the system with a correspondingly low marginal cost. The incorporation of heating and cooling devices into a natural ventilation system is more restricted, due to the low driving pressures. The major appeal of natural ventilation is of course that it is a passive system and, in principle, it is to be preferred to a mechanical system, provided that it can perform satisfactorily. This proviso is of course a key issue, which will depend on many factors (subjective and objective). It can be argued that for many applications, close control of the internal environment is unnecessary (since human beings are adaptable) and unjustified (since the specification of required ventilation rates is subject to considerable uncertainty). Nowadays it is not uncommon for design briefs to specify natural ventilation as the preferred system for commercial buildings.
3.2.3 Low-energy ventilation systems There is no precise definition of what is meant by a low-energy ventilation system, and even less for what constitutes a ‘sustainable’ or a ‘green’ system. Many factors need to be taken into account (Liddament, 1996). In the following we concentrate on the more important ways in which the energy consumption directly associated with the provision of ventilation can be reduced. It is relevant to consider heating and cooling separately and in that order. For a given flow rate of fresh air, Q (m3/s), the heating load, Hv (W), imposed on a building is
Hv = rcpQ(Tin – Tout)
3.1 3
where r denotes density (kg/m ), cp the specific heat (J/kg K), Tin the temperature of the air flowing into the building and Tout the temperature of the air leaving the envelope. The outlet temperature will normally be controlled to a fixed value (room temperature), so the heating load can only be reduced by increasing Tin above the external temperature. This can be done by a heat
© Woodhead Publishing Limited, 2010
80
Materials for energy efficiency and thermal comfort in buildings
recovery system, whereby the inlet and outlet flows are ducted through a heat exchanger. In this way the ventilation heat load can be reduced by as much as 70%. A balanced mechanical system is ideally suited for heat recovery for a complete building. However, there are two problems. First, energy savings are reduced by the extra fan power required to induce the flow through the heat exchanger and associated ducts. Second, with a balanced system there is no pressurization, so any natural ventilation through openings in the envelope simply adds to the ventilation heat load. It is therefore necessary that the envelope should not be too leaky (see Section 3.4.3). Another way of increasing Tin is to arrange for the external air to pass through an underground duct before it enters the envelope. The ground temperature remains reasonably constant, so pre-heating takes place when Text is lower. This approach raises questions about the quality of the air and is not common. The above remarks apply equally to the case when cooling is required (although in Eq. 3.1, the temperature difference is reversed and is smaller). However, there is a major difference, namely that ventilation itself can provide cooling. In certain climates it is possible to obtain acceptable conditions in the cooling season, either by achieving very high flow rates during the occupied period, or by making use of ‘night cooling’. These approaches are discussed in Sections 3.4.5 and 3.4.6. An important point to note here is that a natural ventilation system is often taken to mean one which reduces (or eliminates) the need for mechanical refrigerative cooling. This issue has been brought to the fore in some countries by global warming. For example, in the UK, it is now not uncommon for the cooling requirement of a building to exceed the heating requirement. A natural ventilation system is sometimes viewed as a requirement for a building to be classed as low-energy by virtue of the fact that fans are not used. This is not necessarily correct, since it assumes that the natural flow rates that occur during the heating season are not excessive, i.e. the Q term in Eq. 3.1. Nevertheless, it seems to be generally accepted that a well-designed natural ventilation system can be an important component of a low-energy building, particularly if it also eliminates the need for mechanical cooling. Low-energy forms of mechanical ventilation systems can be achieved by reducing fan energy consumption and by the use of heat recovery. In simple terms the fan energy consumed, EF (J), is given by
EF = 100topQFDp/h
3.2
where top is the operating time (s), QF the fan flow rate (m3/s), Dp the pressure rise (Pa) and h the overall fan efficiency (%). There are various ways that the first three parameters can be reduced. For example, the operating time and the volume flow rate can be reduced by intelligent controls, or by a mixedmode system. Good duct design with bypasses for unused components will
© Woodhead Publishing Limited, 2010
Ventilation, air quality and airtightness in buildings
81
reduce Dp. The use of variable speed motors and aerodynamic fan blades can increase h.
3.2.4 Internal air motion Internal air motion plays an important role in determining both the air quality and the comfort level in a space (provided sufficient fresh air is supplied). In this respect, there are basically two types of mechanical systems. In one, the aim is to thoroughly mix the internal air, so that uniform conditions (e.g. pollutant concentrations, temperature) occur throughout the occupied space. This type is known as mixing ventilation. The second type is known as displacement ventilation and is virtually the opposite. The underlying aim is that pollutants and internal heat gains should rise to a high level, without mixing with the air in the occupied space. This requires the use of a low-velocity, low-level supply and a high-level extract, so that the air is displaced upward. For natural ventilation, the mixing process is more complicated and less predictable. Depending on the wind and temperature conditions, either mixing or displacement ventilation may be evident, or some combination of the two. For example, the former tends to occur with high flow rates, such as encountered with large window openings used for cooling and when wind is the dominant driving force. Displacement ventilation is more likely to occur with low ventilation rates, particularly when buoyancy is dominant. However, both the positions of the openings and buoyancy generated by heat transfer at surfaces can disrupt the classical displacement flow pattern.
3.3
Physical mechanisms
Natural ventilation of a building can be considered as comprising two physical processes, namely envelope flows (the entry and exit of air through openings in the envelope) and internal air motion within the envelope.
3.3.1 Envelope flows In simple terms, flows through openings in the envelope arise as a result of pressure differences acting across the envelope. These pressure differences are generated by temperature differences (buoyancy), by the wind and by mechanical fans. The external velocity field around an opening can also play a role, particularly with large openings, but only the pressure fields are considered here. When describing envelope flows, the term buoyancy refers to the difference between the density of the internal air and the external air. Under the action of gravity, the different densities generate different hydrostatic pressure
© Woodhead Publishing Limited, 2010
82
Materials for energy efficiency and thermal comfort in buildings
variations with height inside and outside the envelope. When wind is present, the variations in air velocity that occur around the building are accompanied by a variation in pressure on the external surface of the building. The absolute pressure at a point on the external surface of the building, PE, is given by the sum of the ‘hydrostatic’ pressure and the pressure due to wind, pw. Thus for a point at height z
PE = PE0 – rEgz + pw
3.3
where PE0 denotes the hydrostatic pressure at z = 0 in the exterior. The density of the external air is uniform and is denoted by rE. The internal pressure on the internal surface is given by the hydrostatic equation. In general there will be air movement inside the building, but the velocities are usually low enough for the pressures due to motion to be neglected. Thus the internal surface pressure, PI, at height z is given by
PI = PI0 – rIgz
3.4
where PI0 denotes the internal hydrostatic pressure at z = 0. (When the internal air temperature and density are not uniform, Eq. 3.3 has a different form.) The pressure difference across an opening, Dp, at height z (inlet and outlet at same height) is thus given by
Dpi = Dp0 – Drgzi + pwi
3.5
where the following substitutions have been made
Dr ∫ rE – rI
3.6
Dp0 ∫ rE0 – rI0
3.7
The equations for the special cases of buoyancy alone and wind alone are obtained by putting pw = 0 and Dr = 0 respectively in Eq. 3.5. Pressure differences generated by natural ventilation are quite small. For a low-rise building they are typically less than 10 Pa and may often be less than 5 Pa. The actual values encountered depend largely on the height of the building and how exposed it is to the wind. When a mechanical fan is used to extract or supply air to a space, it generates a pressure that is uniform over the internal surfaces of the envelope. The magnitude of this pressure is also likely to be less than 10 Pa, which means that natural ventilation can play a role in such systems. A balanced system is particularly susceptible, because it generates no pressure difference (see Section 3.6.1). Internal fans, such as a desk fan, are often used to provide convective cooling of occupants or to enhance mixing of the air. This type of fan primarily affects the internal air motion, rather than the flow through envelope openings.
© Woodhead Publishing Limited, 2010
Ventilation, air quality and airtightness in buildings
83
3.3.2 Flow through envelope openings The flow rate through an opening, qi, can often be expressed in terms of the pressure difference across it, Dpi, by means of the discharge coefficient, Cdi,
qi = Cdi Ai
2Dpi r
3.8
where Ai denotes a defined area of the opening. There will generally be multiple openings in an envelope, and conservation of mass applied to the flow into and out of the envelope provides a relationship between all of the individual flow rates
∑ rqi = 0
3.9
If there are N openings in an envelope, there are N equations of the form 3.5 and 3.8 and one of the form in Eq. 3.9. If the areas, discharge coefficients and positions are known for each opening, the equations can be solved to give Dp0 and the flow rates. This is known as the implicit method of solution. Generally speaking this is an iterative process, whereby Dp0 is altered until the mass conservation equation is satisfied. To some extent, this process mimics what physically happens. When the flow rates change, due to a change of wind speed, for example, the internal pressure changes to re-establish the mass balance.
3.3.3 Characteristics of natural ventilation The ventilation rate of a building, Q, is usually defined as the rate at which external air (fresh air) flows into the building. The qualitative characteristics of a natural ventilation system can be seen by plotting Q against wind speed, U, as illustrated in Fig. 3.1. For the wind alone case, Q increases with U at a rate that depends on the wind direction (the wind pressure distribution depends on wind direction). For the buoyancy alone case, Q is independent of U (Q increases roughly in proportion to the square root of DT). The buoyancy alone values thus appear as horizontal lines. The curve for the general case of wind and buoyancy combined can often be obtained by treating the wind-alone line and buoyancy-alone line as asymptotes and by joining them with a smooth curve, as shown in Fig. 3.1. This approximation is often acceptable. Bearing in mind the changes that occur in wind speed, wind direction and external and internal temperatures with time, it can be appreciated that the magnitude of Q can vary over a wide range in quite short time scales (in the order of hours). Equally important, the direction of the flow through individual openings can change. For example, with one wind direction the flows into a room may all be inward, whereas with another direction they
© Woodhead Publishing Limited, 2010
84
Q
Materials for energy efficiency and thermal comfort in buildings
Wind alone, two values of wind direction
Wind and buoyancy together
Buoyancy alone, two values of DT
0
U
3.1 Illustrative variation of natural ventilation rate, Q, with wind speed, U, wind direction and temperature difference, DT.
may all be outward (i.e. no fresh air supply). For this reason, one aim of natural ventilation design is to fix the flow directions (see Section 3.5.1). The magnitudes are assumed to be controlled by adjustment of the openings (by the occupants or a control system).
3.3.4 Types of envelope openings Openings in an envelope take a wide variety of forms, but they can be classified under two headings, namely purpose-provided and adventitious. As the name implies, purpose-provided openings are ones that form part of the design. Typical examples are air vents, openable windows and chimneys. Adventitious openings are simply all the openings that are not purpose-provided. Typical examples are gaps in the frames of windows, gaps around pipe penetrations and cracks in walls and ceilings. The two types are distinguished by the fact that the position and the geometry (size and shape) of purpose-provided openings are known, whereas this information is rarely known for adventitious openings. Knowledge of the position and geometry of purpose-provided openings means that such openings can be included in a mathematical model of the envelope and the flows through the openings can be calculated. This requires knowledge of the flow characteristic of each opening (discharge coefficient), which can be found either from experimental measurement or from the known geometry. Ventilation through adventitious openings (referred to as infiltration), is much harder to deal with, basically because the openings are unknown. The adventitious leakage of an envelope can be measured (Section 3.4.3) and this allows some account to be taken of infiltration. When measurement is not possible, methods have been developed that enable the leakage to be estimated, but such estimates are subject to considerable uncertainty.
© Woodhead Publishing Limited, 2010
Ventilation, air quality and airtightness in buildings
85
3.3.5 Internal air motion At the detailed level, internal air motion is a particularly complex process, because the motion is three-dimensional, unsteady (turbulent) and often involves an interaction between dynamic and buoyancy forces. In the past, theoretical treatments have relied heavily on empirical relationships for the bulk properties of the flows. Nowadays it is possible to calculate the properties at all points in the space by numerical solutions of the basic equations of motion and heat transfer. The numerical methods are known as computational fluid dynamics (CFD). The methods have been extended to the calculation of air quality and comfort indices. Care and skill are required in the use of CFD, because there are many sources of uncertainty, not the least of which is the specification of the boundary conditions that are required to obtain a solution. One of the underlying problems in describing (and calculating) internal motion is that the flows usually involve recirculation, which basically means that there is no obvious starting point within the flow. In addition, the interaction between the temperature and velocity fields can lead to flow instabilities. Also, the heat transfer at surfaces can play a major role in determining the temperature and velocity fields and this implies that account needs to be taken of the thermal properties of the envelope. In tall spaces, such as atria, temperature stratification can be expected, e.g. the temperature at high level is greater than the temperature at low level in summer time. This can be beneficial, because it will increase the buoyancy pressures and hence the flow rates at lower levels, when wind speeds are low. Negative buoyancy can be used to generate so-called ‘topdown’ ventilation. In summer, pre-cooled (and denser) air at high level is induced to flow downwards, thereby providing cooler air at low levels. A potential problem with this approach is that wind pressures will tend to oppose it.
3.3.6 Air quality A primary role of ventilation is to maintain acceptable air quality inside the building and this is often used for determining flow rates for design. Pollutants emitted inside the building mix with the internal air and are eventually transported out of the building. The mixing process is determined by the internal air motion and the nature of the emissions. However, the bulk characteristics of the process can be seen by considering a single space of volume V (m3), in which the concentration is assumed to be uniform at all times (mixing ventilation), with a steady (constant) ventilation rate, Q (m3/s) and a steady emission rate of contaminant qc (m3/s). Under these conditions, the contaminant concentration at time t (s) is given by (CIBSE, 2005):
© Woodhead Publishing Limited, 2010
86
Materials for energy efficiency and thermal comfort in buildings
C (t ) = Cext +
qc 6 Ê q ˆ Ê Q ˆ 10 – Á Cext – C (0) + c 10 6 ˜ exp Á – t˜ Q Q Ë ¯ Ë V ¯
3.10
where C(t) is the volumetric concentration in parts per million (ppmv), Cext is the concentration in the external air (ppmv) and C(0) is the concentration at time t = 0 (ppmv). The steady state concentration, Cst, is given by: qCO 2 6 3.11 10 Q For commercial buildings the underlying aim is often to maintain body odours at an acceptable level. The CO2 concentration is directly related to the number of occupants and it can be used as a measure of air quality. For example, air quality may be considered to be met if the concentration is kept below 1000 ppmv. Equation 3.11 can then be used to determine the required ventilation rate. If the space is occupied for a short period of time (e.g. a theatre), Eq. 3.10 can be used to give a lower design ventilation rate. The use of CO2 in the above way is based on the assumption that any other contaminants require lower ventilation rates. If this is not the case, the aim should be to reduce the other emissions rather than increase the ventilation rate. A particular problem here is emissions from building materials (Section 3.6.5). Another problem is contamination from external sources. It is clear from Eq. 6.11 that ventilation can do nothing to reduce the steady state internal concentration below Cext. Cst = Cext +
3.4
Feasibility of natural ventilation
Modern natural ventilation systems are direct descendants of techniques that have evolved over thousands of years, e.g. systems based on wind towers owe much to the badgir and malqaf used in the Middle East (Battle McCarthy, 2001). However, modern systems are judged by different standards, particularly for commercial buildings, where mechanical ventilation and airconditioning have led to tight control over the internal environment. Many factors have to be considered when determining whether natural ventilation is feasible, not least the views of the client. Only the main technical ones are considered here.
3.4.1 Climate Some climates can be very challenging for natural ventilation. The two main problems are cooling and humidity. Natural ventilation alone can provide cooling (see Section 3.4.5), but it can do nothing to reduce humidity levels. A climate where humidity is high and the diurnal variation of temperature
© Woodhead Publishing Limited, 2010
Ventilation, air quality and airtightness in buildings
87
is small is perhaps the most challenging for natural ventilation. Naturally ventilated buildings (commercial and domestic) are not uncommon in such climates, although some form of mechanical cooling and dehumidification may be necessary.
3.4.2 Building envelope The building envelope is one of the most important factors in natural ventilation design. It contains the purpose-provided openings and the manner in which they are incorporated can be a major design issue, e.g. double-skin façades. The envelope also contains the adventitious openings and it influences such factors as thermal storage and internal heat gains. These issues are discussed in Sections 3.4.3, 3.4.6 and 3.4.8.
3.4.3 Airtightness (air leakage) It has long been recognized that flow through adventitious openings (known as infiltration) can lead to significant energy loss when a building is heated. This is a problem for both natural and mechanical ventilation and some examples are given in Section 3.6.1. In many countries, standards exist that set down the maximum allowable adventitious leakage of building envelopes. As far as is known there are no requirements for the minimum leakage. It could be argued that the leakage should not be reduced to too low a value, because purpose-provided openings can be sealed (and mechanical systems switched off) by the unwary. Some types of domestic fuel-burning appliances rely on adventitious leakage to provide combustion air. The leakage is commonly defined as the volume flow rate required to generate a pressure difference of 50 Pa across the envelope. Leakage standards are often expressed in terms of permeability, i.e. the leakage per m2 of envelope surface area. For example, in the UK an air permeability of 10 m3/hm2 at 50 Pa is currently the acceptable level, although values of 7 or 5 are considered to be good practice. In countries with more severe winter climates, lower values are used. In many countries there are recommended procedures for measuring leakage. The equipment consists of a fan, a flow meter and a manometer. The fan generates the flow and the pressure difference across the envelope, which are measured by the flow meter and the manometer. By using a pressure of 50 Pa, the measurements should not be greatly affected by the naturally occurring pressures at the time of the test. The disadvantage of this approach is that the leakage measured at 50 Pa is not necessarily representative of the leakage at the low pressures of practical interest (usually in the range 0 to 10 Pa). Adventitious leakage in a naturally ventilated building during the cooling season is of no consequence, because the purpose-provided openings will be
© Woodhead Publishing Limited, 2010
88
Materials for energy efficiency and thermal comfort in buildings
large. However, if some form of mechanical cooling is employed, adventitious leakage can be important.
3.4.4 Occupants The success of natural ventilation design relies heavily on the occupants for three reasons, two of which are active and one that is passive. First, the occupants are assumed to modify the sizes of openings and to take other actions (e.g. use desk fans to promote cooling; reduce internal gains) in order to obtain acceptable conditions. Second, achievement of thermal comfort requires that occupants vary their dress and activities accordingly. Third, it is now generally recognized that occupants passively adapt to the climate, e.g. the acceptable comfort temperature increases as the external temperature increases. However, satisfying thermal comfort requirements in the summer is still a major challenge. This has led to passive and active cooling techniques for natural ventilation systems (Sections 3.4.5–3.4.7). It has also highlighted the importance of reducing internal heat gains (Section 3.4.8).
3.4.5 Cooling (prevention of overheating) A distinction needs to be made between cooling, which implies that the internal air temperature is reduced below the external air temperature, and the prevention of overheating, which means that excessive internal air temperatures are prevented. Prevention of overheating by natural ventilation relies on convective heat transfer to remove internal heat gains. The main features can be seen by considering the simple case used by Dabidian and Etheridge (2007), i.e. a well-mixed space with a constant ventilation rate. Since the air temperature within the room, Tair, is uniform at all times, the rate of change of Tair with time is given to a close approximation by the following equation (conservation of thermal energy for air in room):
rcV
dTair = H f + H int + H v dt
3.12
The terms on the right-hand side are the heat flows to or from the air (taken as positive when the flow is to the air), i.e. fabric Hf, internal heat gain Hint, ventilation Hv, respectively. The rate at which heat is removed by a ventilation rate Q is
Hv = rQ(Text – Tair)
3.13
Clearly, the higher the value of Q, the higher is the value of Hv. However, it is also necessary for Hv to be negative and this requires the internal temperature to be greater than the external temperature. The temperature rise, DT, needs
© Woodhead Publishing Limited, 2010
Ventilation, air quality and airtightness in buildings
89
to be small enough for Tair to lie within the comfort boundary (e.g. DT < 4 K). With high flow rates, such as those achieved with high wind speeds and large open windows, the temperature rise is likely to be well within this limit. In addition, the high internal velocities lead to convective and evaporative cooling of occupants. This is the basic idea behind wind-driven ‘crossflow’ ventilation of dwellings that is popular in hot climates (Ohba et al., 2006). Of course, high wind speeds cannot be relied upon. With buoyancy alone, the low value of DT means that flow rates will be small and the cooling available directly from natural ventilation will be small. This emphasizes that the internal heat gains Hint need to be kept as small as possible (Section 3.4.8). The fabric heat transfer Hf in Eq. 3.13 also plays a part. This can be positive or negative, depending, amongst other things, on the dynamic thermal behaviour of the envelope. In fact, thermal storage by the envelope offers an alternative method of cooling to direct convective cooling.
3.4.6 Thermal storage (night cooling) Night cooling refers to the use of high ventilation rates at night, with the aim of removing heat from the fabric that has been stored during the day. During the following day the cooled fabric can again absorb heat from the internal air, thereby providing passive cooling. For this strategy to be effective, several conditions need to be met. The external temperature change from day to night should be greater than about 10 K. The thermal storage capacity of the envelope should be high (i.e. ‘heavyweight’ construction) and the heat transfer rate between the internal air and the thermal mass needs to be high. The latter requirement is a challenge, because heat transfer by natural convection is relatively low, leading to the need for large exposed areas. In addition the internal heat gains should be low (preferably less than 40 W per m2 floor area). Modern buildings can be designed to enhance night cooling, e.g. an exposed concrete ceiling to give direct thermal contact between the mass of concrete and the air or an underfloor duct to give thermal contact with a concrete floor. These are purely passive systems. Active systems that use fans or pumps to pass air or chilled water through channels in beams are also used. The heat transfer rates are increased by forced convection, but at the expense of fan or pump energy consumption. A more recent development is the use of phase-change materials (Section 3.6.2).
3.4.7 Evaporative cooling When water evaporates it absorbs latent heat and cools the surroundings. Evaporative cooling techniques rely on a dry climate, such as that in the
© Woodhead Publishing Limited, 2010
90
Materials for energy efficiency and thermal comfort in buildings
Middle East. Indeed, the technique whereby a porous material containing water is exposed to a dry air stream has long been used to cool buildings in that area. A modern technique developed for natural ventilation systems is positive displacement evaporative cooling (PDEC) (Ford, 2001). In this system, water is sprayed into the building at high level. Evaporation lowers the temperature and density of the air, which falls under the action of negative buoyancy and flows into rooms at lower level.
3.4.8 Internal heat gains Minimizing the internal heat gains during the cooling season can be crucial to the success or failure of a natural ventilation system. For example, in the UK climate, and as a rough guide, the internal heat gains should be less than 20–30 W per m2 of floor area for purely natural ventilation. Larger values probably require some form of additional cooling (passive or active). Internal heat gains arise from lighting, occupants, electric equipment and solar gains. The reduction of solar gains is an area where materials can make a significant contribution (Section 3.6.3)
3.4.9 Control In its most basic form, a natural ventilation system is controlled by the occupants, but there are other options. Air vents are available that automatically adjust their area in response to the pressures acting across them. They are known as ‘constant flow ventilators’, because the aim is to maintain a preset flow rate above a certain pressure difference. Control can be by some form of BMS (Building Management System), e.g. adjustment of stack flow rates by varying the position of a damper in response to a measurement of CO2 concentration.
3.5
Natural ventilation design
3.5.1 Basic procedures The design of a naturally ventilated building can be a lengthy, complex and iterative process, particularly for a large commercial building, because the ventilation system interacts with other aspects of the design. The specific procedures adopted may be unique to a particular building and/or to design teams. Nevertheless, there are basic procedures that are likely to be employed in the system design and it is these that are summarized here, by dividing the design process into four stages. The first stage is to assess the feasibility of natural ventilation. This will involve consideration of the factors referred to in Section 3.4.
© Woodhead Publishing Limited, 2010
Ventilation, air quality and airtightness in buildings
91
The next stage is to choose a ventilation strategy. In essence this means choosing a flow pattern for the flows through the envelope openings (internal as well as external). The building may be divided into several parts, each with a different strategy. Some rooms or floors in the building may be isolated from the rest of the building. At the other extreme, rooms or floors may form a single cell (in ventilation terms) by the presence of very large openings between them. Figure 3.2 illustrates such a case. The floors are ventilated by cross-ventilation, with fresh air being drawn through the openings by the chimney (or atrium). The advantage of this strategy is that wind and buoyancy act together to maintain the flow pattern, under most weather conditions. This occurs when the internal temperature is greater than the external temperature and the chimney outlet lies in a region of negative wind pressure. The third stage consists of initial design calculations. For the chosen strategy, the initial design aim could be to determine the sizes of openings required to give the required flow rates (magnitude as well as direction) under specified design conditions. This can be done using an envelope flow model, by employing what is known as the explicit method of solution, i.e. the sizes and positions of openings are calculated for specified flow rates. In a North European climate there are usually two basic design conditions, corresponding to winter (heating) and summer (cooling). The first determines the minimum sizes of the openings and the other determines the maximum sizes. The occupants (or other control system) should then be able to exercise the control to satisfy most weather conditions throughout the year. In the later design stage, off-design conditions can be investigated using more sophisticated tools. There is a wide range of tools available, e.g. multicell envelope flow models, computational fluid dynamics (CFD), combined U
TE
TI
3.2 Example of ventilation strategy (flow pattern).
© Woodhead Publishing Limited, 2010
92
Materials for energy efficiency and thermal comfort in buildings
thermal and ventilation models, physical scale modelling. This stage could well be the most time-consuming.
3.5.2 Design criteria In the heating season, where the aim is to minimize ventilation heat loss, the design criterion will probably be to provide satisfactory indoor air quality. In an office, the requirement will often lie in the range from 5 l/s to 10 l/s of fresh air per person, corresponding to control of CO2 and body odours. In the cooling season, the ventilation rate required to prevent overheating will be much larger than that for air quality. Specifying the design rate is more difficult, because it is necessary to take account of the thermal characteristics of the building. Some form of dynamic thermal model can be used to determine the ventilation rate required to give acceptable internal temperatures. An important point to make here is that design flow rates are not precise. Thus the inherent variability of natural ventilation rates is not necessarily a problem, provided that some broad level of control is exercised, either by the occupants or by a control system.
3.6
Issues concerning materials
In the following, those areas where materials can play a significant role are discussed in more detail.
3.6.1 Airtightness (adventitious leakage) The adverse effect that adventitious leakage can have on natural and mechanical systems is illustrated here by results from an envelope model. Figure 3.3 shows results for a naturally ventilated building in the heating season. The air change rate (h–1) is defined as Q (m3/h) divided by V (m3) and is shown plotted against wind speed for a fixed temperature difference of 15 K. The purpose-provided openings have been designed to provide an air change rate of 0.4 h–1 at a relatively severe condition (U = 8 m/s and DT = 20 K). For less severe weather conditions, the openings can be increased in size as required. The four curves show the air change rates that occur when the purpose-provided openings are kept at their minimum value, with additional adventitious openings (corresponding to permeabilities of 0, 5, 10 and 15 m3/h m2). Clearly, permeability has a significant effect on ventilation rates. However, with a permeability of 5, the ‘design’ air change rate is hardly exceeded. Thus, if the purpose-provided openings were kept at their minimum value by the occupants (or by some other control system), the ventilation heat loss would not be excessive.
© Woodhead Publishing Limited, 2010
Ventilation, air quality and airtightness in buildings
93
2.0 Permeability = 0
1.8
Permeability = 5
Air change rate (per h)
1.6
Permeability = 10 Permeability = 15
1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0
0
2
4 Wind speed (m/s)
6
8
3.3 Effect of adventitious leakage on a natural ventilation system. 2.0 Permeability = 0
1.8
Permeability = 5
Air change rate (per h)
1.6
Permeability = 10 Permeability = 15
1.4
Zero line
1.2 1.0 0.8 0.6 0.4 0.2 0.0 0
2
4 Wind speed (m/s)
6
8
3.4 Effect of adventitious leakage on a balanced mechanical system.
The same calculations have been carried out for a balanced mechanical system with heat recovery and a design air change rate of 0.4. The actual ventilation rate is now simply the sum of the infiltration rate and the mechanical supply rate. The results are shown in Fig. 3.4. The effects of adventitious leakage on air change rate are similar to those in Fig. 3.3. However, with
© Woodhead Publishing Limited, 2010
94
Materials for energy efficiency and thermal comfort in buildings
70% heat recovery from the air passing through the heat exchanger, the actual air change rate needs to exceed a value of 0.68 for the benefit of the heat recovery system to be completely negated (shown by ‘zero line’ in the figure). This occurs with a permeability of 10. With a permeability of 5, the benefit of heat recovery is significantly reduced and when allowance is made for the fan energy consumption the effective reduction will be larger. Ideally, the permeability needs to be less than 2 and such low values are achievable (Ford et al., 2007). Achieving an airtight envelope requires consideration at the design and the construction stages. This means specifying quality components and construction techniques in the design stage and ensuring that the techniques are properly followed on site. It is generally recognized that poor construction can be a major source of adventitious openings. Pre-fabrication of components followed by on-site assembly has been found to be a way of achieving tight envelopes, presumably because quality control is easier. A range of products has been developed to assist in reducing leakage. These include proprietary boards and paints. If a building fails the leakage test, it can be time-consuming and expensive to correct the matter. There are recognized procedures for identifying and eliminating leakage sites. This usually involves the use of various sealants. An important issue that does not appear to be covered by current regulations is ageing. A newly built envelope may be satisfactory, but it is known that the leakage of an envelope can increase with time. Increases can occur due to shrinkage or expansion of components, hardening of seals and sealants, settling of foundations and the actions of occupants. Materials that retain their relevant properties over long periods of time could be an important issue here.
3.6.2 Night cooling with phase-change materials (PCM) Conventional night cooling makes use of the storage of sensible heat in the building fabric. To turn a lightweight building into a heavyweight one requires quite large masses of material (e.g. concrete). Phase-change materials (PCM) offer the possibility of storing thermal energy in a much smaller mass. This enhanced energy density makes PCM more suitable for retro-fitting to existing buildings and for incorporation into stand-alone storage systems. However, the use of PCM for night cooling is still in its infancy. There are basically two types of system, namely passive and active. In a purely passive system, the PCM is installed in the building and left to operate with no further actions. A good example of this is plasterboard that contains a layer of micro-encapsulated PCM as used in some Passivhaus designs (Ford et al., 2007). In active systems, the heat transfer to and from
© Woodhead Publishing Limited, 2010
Ventilation, air quality and airtightness in buildings
95
the PCM is enhanced by mechanical means, usually by a fan to provide forced convection (Etheridge et al., 2006). Passive systems rely on natural convection for heat transfer, which is not controllable and tends to be low. Active systems provide higher heat transfer rates at the expense of the energy consumed by the fans or pumps. However, active systems can be controlled and in this way the energy consumed can be minimized, thereby offering a relatively high coefficient of performance (COP) compared to conventional refrigerative cooling. The COP of a cooling device is defined as the cooling rate divided by the power supplied to the device. In addition, the fan can be used to ensure high ventilation rates at night. This is by no means guaranteed with a passive system, simply because the natural driving forces are unreliable. In fact, an active system allows the room temperature to be controlled, as illustrated by curve C in Fig. 3.5. The results shown are theoretical, using the model described in Dabidian et al. (2007), but with a more realistic PCM simulation. Curves A and B correspond respectively to natural ventilation (air change rate = 1.0 h–1 throughout the day) and natural ventilation with night cooling (air change rate increased to 10 h–1 at night). The main requirements for the thermal properties of a PCM for night cooling are as follows. The transition temperature needs to be around 20 °C.
35 A
Temperature (°C)
30
B
25 A 20
C B
15
10
0
4
8
12 Time (h)
16
20
24
3.5 Variation of room air temperature over 24 hours for three cooling strategies: A – natural ventilation, B – natural ventilation with night cooling, C – natural ventilation with night cooling and controlled PCM system.
© Woodhead Publishing Limited, 2010
96
Materials for energy efficiency and thermal comfort in buildings
As well as a high latent heat capacity, the thermal conductivity needs to be high. The reason for this is that the performance of the system depends on the heat transfer into the material. There is little point in having sufficient mass when the heat transfer rates are too low to make use of it. In addition, the properties need to be stable over a long period. When used for night cooling, a lifetime of 10 years implies a lifetime of about 3000 transition cycles. Other important factors for building usage are flammability, toxicity, corrosiveness, cost (capital and maintenance), environmental impact (recycling, embodied energy). Air quality is an important factor when choosing a PCM. The air should not come into contact with the PCM and this imposes requirements on the manner in which the PCM is contained. A particular issue is that of expansion and contraction of the PCM, which could lead to leakage. PCMs that have been used for cooling in buildings are organic (paraffin waxes, fatty acids) and inorganics (hydrated salts).
3.6.3 Reducing solar gains Solar gains can be beneficial in the heating season, but they are undesirable in the cooling season. The thermal capacity of air is low, so a small increase of thermal energy gives rise to a large increase in air temperature and consequent discomfort. Solar gain is often a significant part of the total internal heat gain of a space, and attention has to be paid to reducing it during the cooling season. There are already well-established ways of doing this, e.g. external solar shading devices (CIBSE, 2005). More recently ‘smart’ glazing has appeared, and such developments are promising because of the potential for control, e.g. changing the transmission through the glass as required (Wiggington, 1996).
3.6.4 Porous materials and dynamic insulation Porous materials (strictly speaking permeable materials) may have a role to play in ventilation systems. They can be used as a medium for evaporative cooling. They can also provide what is known as dynamic insulation. With dynamic insulation, the envelope is formed from a permeable material through which the ventilation air is induced to flow by pressure differential. In so doing, the heat transmitted by conductance through the material is transferred to the air (Dalehaug, 1993). This can be appreciated by considering the temperature distribution within the material for the case when the flows of air and heat are opposed (counter-flow). With quite small air speeds (1 m/h), the temperature gradient, dT/dx, at the external surface can be reduced virtually to zero, i.e. the thermal transmittance (U-value) is virtually zero and the only heat loss is that due to ventilation. Provided the
© Woodhead Publishing Limited, 2010
Ventilation, air quality and airtightness in buildings
97
ventilation rate with dynamic insulation is close to that with conventional insulation, dynamic insulation offers considerable reductions in heat loss. Despite the potential advantages of dynamic insulation, there have been very few examples of its use, other than for research. One reason for this is the need to maintain the required flow through the material. The obvious way is to use a mechanical extract system (counter-flow), but the energy required for the fan can significantly offset the gain. In theory, it is possible for dynamic insulation to be driven by natural ventilation, with a wind-driven extractor fan (Etheridge and Zhang, 1998), but this has not been put into practice. Perhaps the most important reason is that the presence of other openings in the envelope will reduce the flow through the porous material. Adventitious leakage is therefore a potential problem, as are purpose-provided openings. It can also be mentioned here that porous materials could be useful for thermal storage with night cooling. The passage of air through the material should enhance the transfer of heat to and from the material.
3.6.5 Air quality In recent years, it has been recognized that building and furnishing materials can be a significant source of pollution in the form of VOCs (volatile organic compounds). The best way of dealing with this type of pollutant (i.e. one that is not related to the number of occupants) is to reduce the emission rate, rather than to increase the ventilation rate above that required for CO 2 control. Many countries now have standards both for emission rates and for testing materials (see Chapter 6). External concentrations of pollutants can be a concern for buildings in urban areas with traffic pollution. In principle, filters can be used to trap particulates and to adsorb some gaseous pollutants (Liddament, 1996). More recently catalytic devices have been developed. These approaches are more suited to mechanical ventilation. An approach that is more appropriate for natural ventilation is to ensure that air inlets are placed well away from the external source. This is not easy and the benefits may be marginal.
3.7
Future trends
The need to reduce carbon emissions and the projected increase in external temperatures associated with global warming are perhaps the two most important factors that will determine future trends in ventilation systems. The first factor increases the demand for low-energy ventilation systems, both natural and mechanical (and mixed-mode). The second factor makes it more difficult to achieve a successful natural ventilation system in the cooling season. Another adverse factor here is the increasing use of electronic equipment in homes and commerce, leading to higher internal gains.
© Woodhead Publishing Limited, 2010
98
Materials for energy efficiency and thermal comfort in buildings
Whether or not the demand for low-energy systems in commercial buildings can be increasingly met by natural ventilation remains to be seen. Emphasis will need to be placed on features that prevent overheating. It is still unclear how successful PCM and smart glazing will be in this respect, but both have potential. During the heating season, a low-energy system requires that the ventilation rate should not significantly exceed that required for air quality. Achieving a tight envelope and maintaining it over the life of the property is important for natural and mechanical systems, particularly for a balanced mechanical system with heat recovery. The materials used in construction are clearly important here and the development of materials that are resistant to ageing could have an impact.
3.8
Sources of further information and advice
There is a vast and growing literature on ventilation (natural and mechanical) and air quality. The following sources can be regarded as a starting point. Textbooks on ventilation Awbi (1991) and Etheridge and Sandberg (1996) cover most aspects of the theory and measurement of natural and mechanical ventilation. Design guides for ventilation Detailed design guidance on many aspects of ventilation is available from professional societies. The American Society of Heating and Refrigeration Engineers (ASHRAE) in the USA, the Chartered Institution of Building Services Engineers (CIBSE) in the UK and the Japanese Architectural Association in Japan are good examples. Self-contained design guides specifically for natural ventilation are relatively scarce. A good example is CIBSE (2005). Liddament (1996) gives guidance on many aspects of low-energy ventilation systems. Standards, regulations Many countries have their own standards and regulations for ventilation, leakage and air quality. A good starting point is AIVC TN55 (2001). Scientific journals The following journals regularly contain technical papers on ventilation and
© Woodhead Publishing Limited, 2010
Ventilation, air quality and airtightness in buildings
99
air quality: ASHRAE Trans, Build Serv Eng Res Tech, Bldg & Env, Energy & Bldgs, Indoor Air, Int J Vent. International conferences The Proceedings of international conferences are a good way of finding latest developments. There is no shortage of them and the short titles of some are AIVC, IAQVEC, Indoor Air, ISHVAC, RoomVent. Further details can be found from their websites. International organisations The International Energy Agency (IEA) promotes and supports research by the member countries of the Organisation for Economic Co-operation and Development (OECD) in a number of areas. One area is energy conservation in buildings and community systems (ECBS). Projects are denoted by Annex numbers and there are several that relate specifically to ventilation, e.g. IEA ECBS Annex 35, IEA ECBS Annex 5. The latter is the Air Infiltration and Ventilation Centre (AIVC) http://www.aivc.org. The AIVC organizes an annual conference and publishes a range of material on ventilation (including a bibliographic database). The European Commission also funds research within the European Community under the framework of the JOULE Programme, e.g. NatVent (1998).
3.9
References and further reading
AIVC TN55, A review of international ventilation, airtightness, building insulation and air quality criteria. Brussels, AIVC, 2001. Awbi H B, Ventilation of buildings. London, E & F Spon, 1991. Battle McCarthy Consulting Engineers, Wind towers. Chichester, Academy Editions, 2001. CIBSE, Natural ventilation in non-domestic buildings. Applications Manual AM10:2005, London, CIBSE, 2005. Dabidian N and Etheridge D W, Simulation of a novel heat pipe/pcm system for cooling of naturally ventilated buildings. Proc. of IAQVEC2007, Sendai, Japan, 2007. Dalehaug A, Development and survey of a wall construction using dynamic insulation. Proc. of Building Physics ’93 – 3rd Nordic Symposium, 1993. Dorer et al., Airtightness of buildings. VIP Note 8, Brussels, AIVC, 2004. Etheridge D W, Murphy K and Reay D, ‘A PCM/heat pipe cooling system for reducing air conditioning in buildings: review of options and report on field tests’. Building Serv. Eng. Res. Tech., 27(1) 27–39, 2006. Etheridge D W and Sandberg M, Building ventilation – Theory and measurement. Chichester, John Wiley and Sons, 1996. Etheridge D W and Zhang JJ, Dynamic insulation and natural ventilation: Feasibility study. Building Serv. Eng. Res. Tech., 19(4) 203–212, 1998.
© Woodhead Publishing Limited, 2010
100
Materials for energy efficiency and thermal comfort in buildings
Ford B, Passive downdraught evaporative cooling: principles and practice. Architectural Research Quarterly, 5(3), 271–280, 2001. Ford B, Schiano-Phan R and Zhongchen D (eds), The Passivhaus Standard in European Warm Climates, European Commission IEE Programme ‘Passive-on’, July 2007. IEA ECBS Annex 5, Air Infiltration and Ventilation Centre, Coventry, ESSU. IEA ECBS Annex 28, Low Energy Cooling, Technical Synthesis Report, Coventry, ESSU, 2000. IEA ECBS Annex 35, Design of Energy Efficient Hybrid Ventilation, www. hybridventilation.dk Liddament M, A guide to energy efficient ventilation. Coventry, AIVC, 1996. NatVent, Overcoming technical barriers to natural ventilation, 1998. Reports available at http://projects.bre.co.uk/natven Ohba M, Goto T, Kurabuchi T, Endo T and Akamine Y, Experimental study on predicting wind-driven cross-ventilation flow rates and discharge coefficients based on the local dynamic similarity model, Int. J. Ventilation, 5(1), 105–114, 2006. Wiggington M, Glass in Architecture. London, Phaidon Press Ltd, 1996.
© Woodhead Publishing Limited, 2010
4
Heat energy storage and cooling in buildings
S. W u, University of Nottingham, UK
Abstract: This chapter introduces the technology of heat storage and cooling and its applications in buildings. It discusses the psychrometrics and air conditioning which are relevant to the thermal energy storage for building thermal comfort applications. The discussion then goes on to three heat storage methods, namely, the sensible, the latent and the chemical heat storage technologies and the issues that are related to the performance of the thermal energy storage. It also presents some of the latest developments in thermal energy storage for energy-saving building thermal comfort applications. Key words: heat storage, thermal energy storage, cooling, building energy.
4.1
Introduction
A considerable amount of energy is consumed in buildings via heating, cooling and dehumidifying to provide thermal comfort. However, the shortage of energy resources and the excessive emission of greenhouse gases resulting from the use of carbon-based energy have rendered such a consumption rate unsustainable. The solution to these unsustainable practices is, perhaps, through increasing the efficiency of our energy usage and utilising renewable energies in order to avoid compromising our living standards. In this aspect, thermal energy storage can play an important role for the following reasons: 1. Thermal energy storage can improve energy efficiency by conserving energy, that otherwise would have been wasted, for later use. Additionally the fluctuations of temperature that compromise the efficiency of thermal systems may also be minimised. 2. Thermal energy storage can also maximise the output from an intermittent renewable energy supply source, such as solar radiation, by increasing its accessibility to applications such as building cooling and heating. As the regulations on the energy performance of buildings tighten, thermal energy storage technologies and their applications in buildings are becoming an increasingly important subject. This chapter covers the contents of psychrometrics and air conditioning that are related to thermal comfort; the principles of the thermal energy storage technologies and their applications for building energy saving. 101 © Woodhead Publishing Limited, 2010
102
Materials for energy efficiency and thermal comfort in buildings
4.2
Psychrometrics
4.2.1
State of air
The air in the atmosphere is a mixture of gases. It contains 78.08% nitrogen, 20.95% oxygen plus a small amount of other gases such as argon and carbon dioxide, etc. Air also contains a variable amount of water vapour. Air that contains no water vapour is called dry air. When air contains water vapour, humidity is a term that is used to describe the amount of water vapour in it. There are two ways to describe how humid the air is: the quantity of water vapour contained in the air (absolute humidity) and the degree to which the air is close to its saturated state (relative humidity). Absolute humidity is expressed in terms of the mass of water vapour contained in one kilogram of dry air, i.e.
w=
mw (kg water ater vapour vapour/kg /kg dr dryy air air)) mg
Here, mw and mg are the quantities of water vapour and dry air, respectively. Since the water vapour and air can be treated as an ideal gas under the relevant conditions, the absolute humidity can also be written in the following form:
w=
0.622 Pw (kg/kg) P – Pw
4.1
Here, P is the total pressure which equals the sum of the partial pressures of dry air and water vapour in the air. Pw is water vapour pressure. Relative humidity is the ratio of mass of water vapour in the air to the mass of water vapour when the air is in saturated state, i.e. the maximum amount of water vapour the air can hold under the same temperature and pressure. If the maximum amount of water vapour is denoted as mw,s, then its vapour pressure is Pw,s, thus according to the definition, relative humidity can be written as:
j=
mw P = w mw,s Pw, s
4.2
Absolute humidity and relative humidity have the following relationship according to Eqs 4.1 and 4.2:
j=
wP (0.662 + w ) Pg
4.3
Both absolute and relative humidity are of dimensionless units. Relative
© Woodhead Publishing Limited, 2010
Heat energy storage and cooling in buildings
103
humidity ranges from 0 to 1 and is usually expressed as a percentage, where 0% indicates that the air is dry and 100% indicates that the air is saturated. When the humidity of air reaches 100%, water vapour in the air begins to condense. This point is called the dew-point. The temperature at which condensation begins as a result of cooling the air (at constant pressure) is called the dew-point temperature. A simple method to measure the humidity of the air is by measuring the temperature difference before and after it undergoes the adiabatic saturation process. The temperature measured before the process is the dry-bulb temperature and the temperature measured after is the wet-bulb temperature. Note that, theoretically, the wet bulb temperature is equal to the adiabatic saturation temperature. The larger the difference between the dry-bulb and wet-bulb temperatures, the lower the humidity of the air. The water vapour in atmospheric air, temperature and pressure are variables in determining the state of the atmospheric air. However, since atmospheric pressure varies within a small range, the pressure is generally represented with the standard atmosphere pressure of 1.013 kPa. Thus, in practice, only temperature and humidity are required for determining the state of atmospheric air. The energy stored in atmospheric air is measured in enthalpy which is a combination of properties u + Pv, in which, u is internal energy and the product Pv is associated with the work potential of the air flow. The enthalpy of a pure substance is a function of temperature and pressure and is given the symbol H. The enthalpy of a unit mass is called specific enthalpy and given the symbol h. Since atmospheric air is a mixture of dry air and water vapour, the enthalpy of atmospheric air is a sum of the enthalpies of dry air and water vapour in the air, i.e., Hm = Hg + Hw, where Hg = mghg, Hw = mwhw, and the mass of the mixture mm = mg + mw. Thus the enthalpy of air can also be expressed in unit mass enthalpy of the atmospheric air as below: m mh m = m gh g + m wh w
4.4
Rearranging Eq. 4.4 and using the definition of absolute humidity, we have: mw hw mg hg + w hw = m 1+w 1+ w mg
hg + hm =
4.5
Equation 4.5 can be used to calculate the specific enthalpy of the atmospheric air if the temperature, pressure and humidity are known. The enthalpy of atmospheric air based on per unit dry air is commonly used. In this case,
© Woodhead Publishing Limited, 2010
104
Materials for energy efficiency and thermal comfort in buildings
h=
Hm = hg + w hw mg
4.6
In engineering practice, a psychrometric chart is constructed to show the relationship between the dry-bulb temperature, web-bulb temperature, dewpoint temperature, absolute humidity, relative humidity, volume and enthalpy of atmospheric air per kilogram dry air. Among the seven variables, only two are independent, i.e., if both the independent variables are known, the rest are also known. The psychrometric chart is very useful in analysis of the air processes in air-conditioning and evaporative cooling.
4.2.2
Surface and interstitial condensation
The moisture in the air can cause surface and interstitial condensation to building structure. When the surface temperature of walls, floors and ceilings is below the air’s dew point, water vapour will condense on them and the condensate can diffuse into the materials. For materials with large pores, moisture penetration can occur. When the material temperature falls below the dew-point temperature of the air, interstitial condensation can occur within the pore structure of the materials. Surface and interstitial condensation are closely related to the properties of the materials such as thermal conductivity, vapour permeability, water sorption and diffusivity, density and specific heat capacity. The long-term effects of condensation can have a significant influence on the strength of building structures.
4.2.3
Principles of air conditioning
Air conditioning is the process of cooling and dehumidifying indoor air to meet the requirements of thermal comfort or other purposes. A common method of cooling and dehumidifying is by contacting the air to a cold surface such as an evaporator. Thus whilst the temperature of the cold surface is usually below the dew-point of air, some of the water vapour in the air condenses as the air is cooled to below dew-point, thereby removing water from the air. It should be noted that while this process decreases the absolute humidity, it actually increases the relative humidity of the air to 100%. In order to reduce the relative humidity, a heating process is needed. This can be achieved through warming the air by simply heating it or by mixing it with another stream of warm air. This process can be drawn on a psychrometric chart as shown in Fig. 4.1. The lines of b–2 and b–2¢ in Fig. 4.1 represent the processes of the air being warmed up without water vapour taken in or being mixed with another stream of warm air with higher humidity, respectively. Cooling devices used for air conditioning can be electrically powered
© Woodhead Publishing Limited, 2010
1
a
w1
2¢ b
2
w2
105
Absolute humidity
Heat energy storage and cooling in buildings
T1 T2 Dry-bulb temperature
4.1 Processes of air conditioning on psychrometric chart.
mechanical refrigerators, heat powered absorption refrigerators or any systems that can produce cooling below the dew-point temperature of the air. Dehumidification and cooling of air can also be achieved using the desiccant and evaporative cooling method. This method involves using a substance which has a strong affiliation with the water vapour in the air as a solid adsorbent, or liquid absorbent, to remove water vapour from the air. upon contact with the absorbent (adsorbent), water vapour is taken into the liquid absorbent via diffusion or bound onto the surface of the solid absorbent. This sorption is an exothermal process. The heat generated in the process has to be removed in order to sustain the sorption. Typically, the heat is removed as it is generated. This is an isothermal sorption process as both the air and the absorbent (adsorbent) remain at a constant temperature. The heat can also be removed after the sorption. In this case, sorption takes place adiabatically and the heat generated in the process is held by both the air and the absorbent (adsorbent). As a result, the air temperature rises in the process. Cooling the air may be required to reduce the temperature to the desired level for air conditioning. This can be achieved by adiabatically evaporating water into the desiccated air. The amount of water evaporated, mf, is determined by the decrease in air temperature and the flow rate of the air if ignoring the heat absorbed by water: maCp(T1 – T2) = mf hfg
4.7
If the absolute humidity of the air after the desiccant process is denoted as w1, then the temperature decrease of the air, and the increase in the absolute humidity of air after the cooling process, can be approximately determined from the following:
w 2 – w1 ª
Cp (T1 – T2 ) h fg
© Woodhead Publishing Limited, 2010
4.8
106
Materials for energy efficiency and thermal comfort in buildings
Since T2 and w2 have to meet the requirements for air conditioning, Eq. 4.8 sets the minimum requirements for the temperature (T1) and humidity (w1) that the air should reach after passing through the desiccant process. Since the sorption is an exothermal process, the heat generated in the process will increase the temperatures of the air and the sorbent. The temperature rise of the air depends on the heat distribution between the air and the absorbent (or adsorbent). The distribution can be expressed by a ratio of the heat received by the air to that by the absorbent or adsorbent. A high distribution ratio indicates that more of the heat is transferred to the air. If the distribution ratio is too large, the subsequent evaporative cooling may be unable to cool down the air temperature at the desired humidity. In this case, the air must be pre-cooled before it enters the evaporative cooling process in order to achieve the required air conditioning. If the humidity of the atmospheric air is low enough that water can directly evaporate in the air to cool down the air, the desiccant process is not necessary.
4.3
Fundamentals of thermal energy storage
4.3.1 Energy in substances A substance contains energy which can be divided into macroscopic and microscopic forms. The former refers to the energy that a substance possesses as a whole with respect to the outside reference frame; the latter refers to the energy that is related to the molecular structure and activity of a substance, independent of the outside reference frame. The microscopic form of energy is called internal energy in thermodynamics. The transfer of this energy between the systems is called heat. Strictly speaking, heat is not a form of energy but a quantity of internal energy transferred, although the term heat energy is widely accepted. So, heat storage is the storage of additional internal energy that has been acquired by heat absorption. The internal energy can be divided into two categories according to what it is associated with: those relating to the kinetic energy of the molecules, atoms and electrons, and those relating to the binding forces between the molecules, atoms and particles of a substance. If the change of internal energy is a consequence of kinetic energy change, then the change is accompanied by a change in temperature. The heat associated with kinetic energy change is called sensible heat. If, however, the change of internal energy is a consequence of a change in the binding forces, then the change is accompanied by a form change of the substance, which could be the result of a phase change relating to weak physical bonds or the result of a chemical reaction relating to strong chemical bonds. It is called ‘potential heat’, when the heat is associated with a phase change, or ‘reaction heat’, when the heat is associated with a chemical reaction. These heats are not associated with temperature change. © Woodhead Publishing Limited, 2010
Heat energy storage and cooling in buildings
107
Heat storage is realised by converting input heat into the internal energy of the materials. Since input heat can increase kinetic energy and/or change the physical or chemical bonds present within the materials, the methods of heat storage can be characterised accordingly as: sensible heat storage, latent heat storage or chemical heat storage.
4.3.2
Sensible heat storage
Sensible heat storage stores heat in the form of kinetic energy in materials. The heat excites the molecules and/or atoms of the storage media so that the heat is converted into internal kinetic energy. The temperature of the storage media will increase as a result of increase in kinetic energy. For a thermal system like a sensible heat storage device, the change in the internal energy of the thermal system, if considering only the heat exchange and the work done between the thermal system and the surroundings, can be described by the first law of thermodynamics: dU = dQ – dW If the heat transfer is a reversible process and the work is done as a result of change of volume, the first law becomes: dU = TdS – pdV
4.9
Entropy may be described as a function of temperature T and volume V, i.e. S = S(T, V) The change in entropy can be expressed as follows: Ê ∂S ˆ Ê ∂S ˆ dS = Á ˜ dT + Á ˜ dV Ë ∂T ¯ V Ë ∂V ¯ T Substituting dS in Eq. 4.9 with the above equation and using the Maxwell relations (Cengel and Boles, 1998), Eq. 4.9 can be rewritten as follows: Ê Ê ∂P ˆ ˆ dU = Cv dT dT + Á T Á ˜ – P˜ ddV Ë ¯ ∂ T Ë ¯ V The first term on the right represents internal energy varying with the temperature – this is proportional to the specific heat, Cv, of the materials provided that volume is constant. The second term on the right represents the volume effect on the internal energy. Since the volume of solid or liquid does not vary greatly with pressure, this effect can be ignored without significant sacrifices in accuracy, provided that the materials used as the storage medium
© Woodhead Publishing Limited, 2010
108
Materials for energy efficiency and thermal comfort in buildings
are liquid or solid. This leads to a simpler relationship between the internal energy and temperature:
dU = CvdT
It should be noted that the specific heat Cv is not a constant in general. Therefore, the relationship between temperature and internal energy is not linear. Specific heat and temperature The specific heat discussed until now is a thermal property that can be understood as the change in the internal energy per degree temperature change of 1 mol (or 1 kg) substance under constant volume. As mentioned previously, this part of internal energy associated with sensible heat is stored in the form of kinetic energy, relating to the translation, rotation and vibration of the molecules. These activities are temperature dependent; therefore, the specific heat is a function of temperature. Since the rotation and vibration of the molecules only start to become more vigorous at higher temperatures, one can expect that more energy is required per degree temperature rise at higher temperatures. This results in higher values of specific heat at high temperatures. Figure 4.2 shows how the specific heat of water varies with temperature. It can be seen from the figure that specific heat increases with temperatures from 20 °C upward. The initial rise of the specific heat is small until the temperature reaches 300 ºC after which a dramatic increase follows. The increase at temperatures above 300 ºC reflects the significant contribution of the rotation and vibration of the molecules in absorbing the energy. It should be noted that there is another specific heat which is defined under 16 14
Cp (kJ/kg°C)
12 10 8 6 4 2 0 0
100
200 T (°C)
300
400
4.2 The specific heat of water varying with temperature.
© Woodhead Publishing Limited, 2010
Heat energy storage and cooling in buildings
109
constant pressure and denoted as Cp. The constant pressure specific heat, Cp, is used in the processes where the volume change becomes significant. In such cases, the energy change of a system as a result of temperature change includes work done to the surroundings plus internal energy. This energy change is usually measured by the combined thermal property of a substance, termed enthalpy – the sum of work and internal energy for convenience. However, in the case of liquids and solids, the difference between ‘constant pressure’ and ‘constant volume’ specific heats becomes less significant as the volume of liquid and solid substances vary insignificantly. More general theoretical relationships between the specific heat and temperature for solid and liquid can be found in White (1999). Knowing how the specific heat of a substance varies with the temperature is important when choosing a storage medium for a sensible heat storage system in order to optimise heat storage performance. Specific heat and molecule structure According to the theory of equipartition energy (White, 1999), the kinetic energy part of internal energy is associated with the number of degrees of freedom of motion. The specific heat of a substance therefore varies with the structure of the molecules. Since a monatomic species only has translational motion, it has three translational degrees of freedom. In addition to translational motion, a diatomic molecule has two rotational degrees of freedom (the rotation on its own axis cannot be counted as a degree of freedom) and one vibrational degree of freedom, and thus a diatomic molecule has six degrees of freedom in total. Since each degree of freedom holds kinetic energy independently, the total kinetic energy of a molecule is the sum of these. A diatomic molecule can possess two times the kinetic energy of a monatomic species at the same temperature. In other words, the specific heat per mole of a diatomic molecule substance is twice that of the monatomic species. Thus, a more complicated molecule has a higher molar specific heat. For example, the specific heat of helium (a monatomic gas) is 12.47 kJ/(kmol K) or 3.1156 kJ/(kg K) while the molar specific heat of hydrogen (a diatomic gas) is 20.53 kJ/(kmol K) or 10.183 kJ/(kg K) (Cengel and Boles, 1998). However, it should be noted that this is not always true when the specific heat is mass based. For example, the specific heat of carbon monoxide gas is 0.744kJ/(kg K) which is much lower than that of helium 3.1156 kJ/(kg K). This is because the high molar specific heat is weighted down by its heavy molar mass. Capacity of sensible heat storage The sensible heat storage stores thermal energy in a heat storage medium whose temperature change is the result of the addition or removal of heat.
© Woodhead Publishing Limited, 2010
110
Materials for energy efficiency and thermal comfort in buildings
The capacity of sensible heat storage is determined by its specific heat and the mass of the heat storage medium as well as the allowed temperature change in operation: Q = mCvDT
4.10
Since m = rV, the heat capacity of the sensible storage can also be written as follows: Q = rVCvDT
4.11
Analogous to the definition of density, we can define the thermal density of a thermal storage medium by rearranging Eq. 4.11: Q = r Cv VDT
4.12
Thermal storage density is an important parameter when choosing a storage medium for sensible heat storage systems. It is desirable to have a heat storage medium with a high value of rCv in order to reduce the volume of the heat storage system. The heat capacity of a sensible storage system can also be expanded by increasing its operation temperature difference. However, this is limited by the operational temperatures of the application and the heat source.
4.3.3
Latent heat storage
Change of phase We are all familiar with the phenomenon that under normal atmospheric conditions, water appears in solid, liquid and vapour states when the temperature of water is below 0 ºC, between 0 ºC and 100 ºC and above 100 ºC, respectively. We use the term ‘phase’ to describe the physical state of a substance. The transition of a substance between the states is called change of phase which is the result of a change in the physical bonds between the particles of a substance. Change of phase is unrelated to the kinetic energy of molecules as was discussed; therefore, there is no change of temperature during transition between phases. The state of a single component substance can be determined by three variables: pressure (P), temperature (T) and volume (V). Figure 4.3 shows the phases of a substance changing with P, T and V. In Fig. 4.3(a), the lines show that there are three possible ways for a substance to change its phase, namely, sublimation (from solid to vapour), melting (from solid to liquid) and vaporisation (from liquid to vapour). Further observation of Fig. 4.3(a) and (b) will determine that sublimation can take place only at low pressures and results in significant volumetric
© Woodhead Publishing Limited, 2010
Heat energy storage and cooling in buildings
111
P
Meltin Liquid
p Va
ion imat Subl Triple point
is or
at
io
n
Critical point Liquid
Critical point
Solid
Solid
Solid-Liquid
g
P
Vapour
Liquid-Vapour
Vapour
Solid-Vapour T
(a)
(b)
V
4.3 A typical phase diagram of a substance under (a) P–T and (b) P–V coordination.
changes. This is problematic in practice for a heat energy storage system and thus a phase change heat storage based on sublimation is usually not considered. Similarly, vaporisation also causes large volumetric change but at high temperature and pressure. Thus, heat storage systems based on vaporisation are required to withstand high temperatures and pressures. This is, therefore, unfavourable as a result of the high costs. The melting of a substance occurs at temperatures between sublimation and vaporisation and with the least volumetric change. Therefore, heat storage systems based on melting are very suitable for building applications where modest heat storage temperatures are required. Condition of phase change From a micro perspective, a change of phase is a change in the strength of the physical bonds between molecules or atoms of a substance. Melting, for example, is the result of a decrease in the number of physical bonds between molecules or atoms. In order for this to occur, the molecules or atoms must gain sufficient momentum to overcome the bonds between them. Thus, changes of phase take place only at certain temperatures. When a substance is changing its phase, it can be considered as particle exchange between two systems of different phases. The driving force that causes the exchange is called chemical potential – a measure that is equivalent to the temperature in heat transfer. Chemical potential For a single component system, if a substance exchanges its particles (or mass) with the surroundings, the change in internal energy as a result of the loss
© Woodhead Publishing Limited, 2010
112
Materials for energy efficiency and thermal comfort in buildings
or gain of the particles can be included in the first law of thermodynamics in the following form: dU = TdS – PdV + mdN
4.13
where N is the number of particles in the system. If the change in internal energy is caused solely by the exchange of the particles, i.e., dS = 0 and dV = 0, we have the following equation:
m = ÊÁ ∂U ˆ˜ Ë ∂N ∂N ¯ S ,V The above equation defines the chemical potential of a substance or the change of internal energy with respect to the variation of particles in the system. In practice, the condition of keeping entropy S and volume V constant is difficult to maintain. For phase change processes with constant temperature and pressure, use of the Gibbs function to define the chemical potential is convenient. The Gibbs function is defined as: G = U + PV – TS Differentiation of the Gibbs function results in: dG = dU + PdV + VdP – TdS – SdT Substitute dU with Eq. 4.13 and the above equation becomes: dG = VdP – SdT + mdN
4.14
under the condition of constant pressure and temperature, we have the chemical potential in the following form:
m = ÊÁ ∂Gˆ˜ Ë ∂N ∂N ¯ P , T
4.15
The above equation indicates that the exchange of particles in a process under constant pressure and temperature is proportional to the change in the Gibbs function. It is known that a system is stable when the Gibbs free energy of the system is minimal. This can be used to decide the direction of a phase change process. The following is a derivative of the Gibbs function: Ê ∂G ˆ Ê ∂G ˆ Ê ∂G ˆ dG = Á ˜ dT + Á ˜ dP + Á ˜ dN Ë ∂T ¯ P , N Ë ∂P ¯ T , N Ë ∂N N ¯ P, T Comparing Eqs 4.14 and 4.16, we have Ê ∂G ˆ Ê ∂G ˆ Ê ∂G ˆ –S = Á ˜ , V = Á ˜ , m = Á ˜ Ë ∂T ¯ P , N Ë ∂T ¯ T , N Ë ∂N N ¯ P, T
© Woodhead Publishing Limited, 2010
4.16
Heat energy storage and cooling in buildings
113
For a phase change process with constant temperature and pressure, the phase change should lead to a falling Gibbs free energy, i.e., dG < 0, until the equilibrium between the phases is established, i.e., dG = 0. This means that for a two-phase system whose phases are denoted as 1 and 2, the process can be described by the following equation: Ê ∂G ˆ Ê ∂G ˆ dG = Á 1 ˜ dN1 + Á 2 ˜ dN 2 ≤ 0 Ë ∂N Ë ∂N N1 ¯ p, T N 2 ¯ p, T Since the loss of a particle in one phase should be equal to the gain in the other phase, i.e., dN1 = –dN2, this gives: ÈÊ ∂G ˆ Ê ∂G ˆ ˘ dG = ÍÁ 1 ˜ – Á 2 ˜ ˙ dN dN1 ≤ 0 N1 ¯ P , T Ë ∂N N 2 ¯ P, T ˙ ÍÎË ∂N ˚ If dN1 is greater than zero, whereby phase 1 receives the particles, the chemical potential difference in the bracket must be equal to or less than zero, i.e., m1 – m2 ≤ 0. This indicates that the phase change happens when there is a difference of the chemical potentials between the phases and that the particles are transferred towards the phase with the lower chemical potential. The phase change stops when both phases have the same chemical potential, i.e., m1 – m2 = 0. Figure 4.4 shows a general specific Gibbs function versus temperature curve under constant pressure (Finn, 1993). The two curves in the figure represent the specific Gibbs functions of two phases in a system. The cross point of the two curves is the state at which the two phases are in equilibrium with the temperature at this point TP. Assume that the two phases under g
gL gs gs
gL Solid
Liquid Tp
T
4.4 Gibbs functions of two phases around the equilibrium state.
© Woodhead Publishing Limited, 2010
114
Materials for energy efficiency and thermal comfort in buildings
consideration are solid and liquid, respectively. It can be seen from the diagram that the liquid phase is the stable phase when T > Tp. The solid phase becomes the stable phase when T < Tp. Charge heat to the two-phase system will shift the temperature to T > Tp, thus there will be a transition from the solid phase to the stable liquid phase until the two phases return to the original equilibrium state Tp. A difference of Gibbs function between the phases is necessary for the phase change to occur. However, this has to be kept low in order to avoid lowering the usefulness of the energy in the phase change. It is potentially a challenge to maintain the phases in equilibrium in a melting/solidification energy storage system. When the storage medium in such a system is being charged with heat, the solid phase close to the heated surface will begin to melt first. This results in a heated surface surrounded by the liquid. Continuing the charge of heat to the heat storage system will increase the temperature of the liquid phase. Since there is no solid phase, no phase change occurs until the heat reaches the liquid and solid interface. This will drive up the charging temperature and slow down the charging rate – and vice versa in the reverse process. The latent heat The phase change of a substance is always accompanied by heat transfer and volume change. Their relationship can be expressed using the Clausius– Clapeyron equation:
g dP = dT T (v2 – v1) Here, g is the heat transfer involved in the phase change and is called latent heat. The latent heat is an important parameter for the heat storage medium of an energy storage system where the energy is stored through phase change. The Clausius–Clapeyron equation links the slope of the phase boundary with the change in volume of the substance. It provides a way of determining the latent heat by measuring the slope of the saturation curve on a P–T diagram and also the specific volume at the given temperature. A positive slope, dP/dT > 0, indicates that the substance contracts when it changes phase from liquid to solid. A negative slope, however, means that the substance expands when it changes phase from liquid to solid. Water is one of the few substances belonging to the latter group. Capacity of latent heat storage Latent heat storage stores heat in a storage medium in the form of potential energy between the particles of the substance. The conversion between the
© Woodhead Publishing Limited, 2010
Heat energy storage and cooling in buildings
115
heat and the potential energy within the substance involves a phase change – thus heat storage occurs without significant temperature changes in the storage medium. The capacity of latent heat storage can be determined by the following: Q = mg where g is latent heat in kJ/kg. The thermal storage density of the storage medium can be expressed as below, Q = rg V Since the latent heat of a substance is much greater than the specific heat of the same substance, latent heat storage can store the same amount of heat in a much smaller volume. This is a significant advantage of latent heat storage systems.
4.3.4
Chemical heat storage
Chemical heat storage occurs via endothermic reactions between substances through which thermal energy is stored as the potential energy either between atoms (chemical bonds) or between molecules (van der Waals interactions – a physical bond). Chemical heat storage that involves chemical bond change is called reaction-type storage while one that involves van der Waals interactions is sorption-type storage. The discharge of heat from chemical heat storage systems is an exothermic process through which the substances involved return to their original states before the endothermic reaction takes place. Sorption heat storage The sorption heat storage technology involves at least two components: one as the sorbent and the other as the sorbate. upon contact, the sorbate undergoes a phase change that releases heat. This is the discharge process of a heat storage system that provides the energy for applications. The heat storage is achieved by a reverse process which separates the sorbate from the sorbent in a sorption heat storage system. By heating the sorbent the sorbate gains sufficient momentum to overcome the bonds of the sorbent and as a result, the sorbate changes its phase in the process. This process is sometimes described as desorption. This process brings the sorbent back to the initial state so that it can take the sorbate again. In the sorption heat storage process, the sorbent does not store the heat but changes its chemical potential. Most of the input heat is carried away by the sorbate during its
© Woodhead Publishing Limited, 2010
116
Materials for energy efficiency and thermal comfort in buildings
phase change. This type of heat storage does not require thermal insulation as long as the content of the sorbate in the sorbent does not increase. There are two different sorption processes: one is called absorption – a process in which the sorbate diffuses into the liquid or solid sorbent accompanying a phase change; the other is adsorption – a process where the sorbent does not diffuse into the sorbent but changes phase on the surface of the sorbent. In practice, absorption uses a liquid sorbent (usually called absorbent) while adsorbent uses solid sorbent (called adsorbent). Absorption is characterised by two independent variables among temperature, pressure and concentration. The force behind the absorption is the difference of the chemical potential between the absorbent and the sorbate. For an ideal binary solution system consisting of components A and B, the chemical potential of component A in the solution can be expressed by the following (Blundell and Blundell, 2006):
m A¢ = m A0 + RT ln x A If this solution is in equilibrium with the pure component A which has the chemical potential:
m A = m A0 + RT ln
PA PA0
then under constant temperature and pressure, the chemical difference between them is zero, i.e., m A¢ = m A . Adding heat to the solution will increase the temperature of the solution and thus break the equilibrium; however, the system can only be in a stable state when the Gibbs free energy reaches a minimum, i.e., the system is in a new equilibrium. This can be achieved only by reducing the molar fraction of the component in the solution. As a result, some of the component A in the solution turns into the pure component A. This process will continue until a new equilibrium is reached. Once the heating ceases and the temperature of the solution decreases, the solution will be in a state with lower chemical potential. This enables the solution to absorb component A. The heat recovered from the absorption can be calculated from the concentration changes of the absorbent in the solution. If the concentration of the sorbate in the solution changes from x1 to x2 during an absorption process, then the amount of sorbate taken by the solution is m = m 2x 2 – m 1x 1 Since the amount of the absorbent does not change during the absorption, the following relationship exists: m2(1 – x2) = m1(1 – x1)
© Woodhead Publishing Limited, 2010
Heat energy storage and cooling in buildings
117
From the above two equations, the amount of the sorbate can be derived as the following: m=
x2 – x1 m1 x1
Therefore, the heat released from condensation of the sorbate is Qc = m (h2 – h1) =
x2 – x1 m1 (h2 – h1 ) x1
Solution heat, which is the enthalpy difference as a result of the variation in concentration, will also be generated in the absorption: Qs = m2 h2,s – m1h1,s =
1 – x1 m1 (h2,s – h1,s ) 1 – x2
The total heat that can be recovered is: Èx – x1 ˘ 1 – x1 Qc + Qs = m1 Í 2 (h2 – h1) + (h2,s – h1,s )˙ x 1 – x 2 Î 1 ˚ The heat storage capacity of a unit absorbent can be written as the following: Qc + Qs x – x1 1 – x1 = 2 (h2 – h1) + (h2,s – h1,s ) m1 x1 1 – x2 Since the sorbate in the absorption storage system involves the phase change from vapour to liquid, a large heat storage capacity can be obtained. unlike the sensible heat storage, this method does not require storing the absorbent at high temperature. It only requires the absorbent be kept at a low concentration of the sorbate. Therefore, insulation is not needed to prevent the heat loss from the storage tank. The adsorption storage systems store thermal energy in a similar way to absorption storage systems. However, since adsorption only takes place on the surface of the adsorbent, the adsorbent must have a large surface area for adsorption. An adsorbent with a large ratio of surface to volume will help to maximise the amount adsorbed, and therefore the heat released. However, in order for the inner surfaces of the adsorbent to be accessible to the vapour which has a large specific volume, sufficient passages between the adsorbent must be provided. This will add a significant volume to the adsorbent. So, adsorption thermal storage systems are generally associated with large volume.
© Woodhead Publishing Limited, 2010
118
Materials for energy efficiency and thermal comfort in buildings
Reaction heat storage Reaction heat storage involves a thermo-chemical process in which the participating reactants undergo a reversible chemical reaction. The process can be generally expressed as following:
A + B ¤ AB + DH
Here, DH is the reaction heat. Depending on the type of the reaction, DH can be positive or negative. Since a chemical reaction involves change of chemical bonds, one can expect the heat storage capacity of systems using reaction heat storage technology to be of high density. For example, the carbon dioxide reforming of methane can provide a reaction heat of 247 kJ/ mol (Lovegrove and Luzzi, 1996).
4.3.5 Heat transfer in heat storage systems Previous discussions have shown that heat storage is achieved by changing the internal energy of the materials by transferring heat to them. In sensible heat storage systems, the temperature difference between the heat source and the storage media is the force for the heat charging or discharging process. For this to happen, a force induced by heat is necessary regardless of the technologies (the sensible, phase change or chemical heat storage) that are used in the systems. The forces are the temperature difference in the case of sensible heat storage and the chemical potential difference in the case of phase change and chemical heat storage systems. Heat transfer in heat storage systems can have a significant effect upon them.
4.4
Materials for thermal energy storage
4.4.1 Materials for sensible heat storage As discussed previously, gas is not a suitable thermal storage medium for sensible thermal storage systems due to its large specific volume. The materials used as storage media in sensible thermal storage systems are usually in either solid or liquid phases. In order to increase thermal storage density, thermal storage systems need high thermal density materials as the storage media. These materials also have to be low cost and easy to source since storage systems need large quantities of the material to meet the required storage capacity. Table 4.1 gives some common building materials that are used as storage media in sensible heat storage systems and could be used in buildings. Table 4.1 also indicates that solid materials possess thermal density values far higher than liquid media. The thermal density of concrete is approximately 466 times greater than that of water at 20 ºC. Thus, solid materials are generally better thermal energy storage media. © Woodhead Publishing Limited, 2010
Heat energy storage and cooling in buildings
119
Table 4.1 Thermal density of some storage media at 20 °C Name
Density (kg/m3)
Specific heat (kJ/kg K)
Thermal density (kJ/m3 K)
Solid Concrete Brickwork Wood Granite Glass Sandstone Aluminium Steel Coarse-grained earth
2200 1600 600 2750 2800 2200 2707 7833 2040
0.88 0.84 2.4 0.89 0.8 0.71 0.896 0.465 1.84
1936 1344 1400 2448 2240 1562 2425 3642 3754
Liquid Water Engine oil
0.9982 0.884
4.158 1.91
4.151 1.688
Source: Bejan (1993)
Thermal conduction is a major issue with solid non-metallic storage media. The rate of thermal conduction inside the materials is potentially far slower than the rate at which heat would be charged or discharged on their surfaces. This could result in large temperature differences between the surface and inside of the materials. For a large block of the solid materials, this means the heat takes a much longer time to reach the innermost parts of the materials. Therefore, the large size, non-metallic solid blocks are not suitable for applications that require high rate heat storage with a frequent charge/discharge cycle. Metallic solid materials perform much better in this respect, though the high cost of the metals makes it uneconomic. Practically, nevertheless, heat transfer in non-metallic heat storage media can be improved by using smaller size non-metallic solid particles instead of large ones. This shortens the heat travelling distance to the innermost parts of the material. The use of the small size particles will slightly reduce the thermal density of the materials due to the additional voids between them; however, the voids could be used as fluid paths to enhance the heat transfer on the surface of the particles by convection heat transfer. This arrangement can allow nonmetallic solid sensible heat storage systems to simultaneously provide the desired high thermal storage densities as well as high charging/discharging rates, although a match between the size of particles and the velocity of the fluid must be made with care.
4.4.2 Materials for latent heat storage Many materials can be used as latent heat storage media if the phase changing temperature of the material is within the required operating range. Materials © Woodhead Publishing Limited, 2010
120
Materials for energy efficiency and thermal comfort in buildings
with high latent heat are advantageous in pure latent heat operation, since this increases the potential thermal storage density. Some latent heat storage systems may be required to operate in a wide range of temperatures. In such cases, sensible heat can be a significant part of the heat stored and the specific heat of the storage media may need to be taken into account along with the latent heat if the heat storage capacity is to be maximised. The term ‘phase change material’ (PCM) refers particularly to materials that store thermal energy in the phase change from solid to liquid. PCMs can broadly be arranged into three categories: eutectics, salt hydrates and organic materials. For building thermal energy storage applications where the operating temperature falls in the range between 0 ºC and 100 ºC, only salt hydrates and organic materials are suitable. Generally, PCMs for such low temperature applications (below 100 ºC) have low thermal conductivities – a range between 0.1 W/m K and 1 W/m K (Lane, 1980). The slow heat transfer due to the low thermal conductivities of the materials used can potentially prevent heat from reaching all of the phase change materials. This effectively reduces the total capacity of the heat storage. This problem can be addressed by reducing the size of PCMs in the storage systems to reduce the heat transfer resistance within the PCM. Encapsulation of the PCM is a way to divide a large quantity of PCM into small individual particles. The encapsulated small PCM particles reduce the heat travel distance within the PCM and provide a larger specific surface to volume ratio; this is an effective way to improve the overall heat transfer of the latent heat storage systems. Encapsulated PCM particles can be packed into a heat storage bed or formed into slurries for use in liquid applications. Encapsulation can also be achieved from the integration of PCMs with solid materials to form functional construction materials.
4.4.3 Materials for chemical heat storage Different from the sensible or latent heat storage materials, chemical thermal storage materials work as pairs in thermal storage systems. The sorbent is a component of the working pair in a sorption type chemical thermal storage system. The sorbent is not responsible for storing the thermal energy, and thus, its thermal mass is not of major concern. Contrarily, a low sorbent thermal mass will reduce the thermal inertia of the thermal energy storage system and so the speed at which the system responds to demand increases. Chemical thermal storage is very suitable for incorporating with certain heat powered refrigeration systems, such as vapour absorption and adsorption, to provide cooling to buildings. The working pairs used in these systems can be used directly as thermal storage materials. Table 4.2 lists some commonly used working pairs in these systems.
© Woodhead Publishing Limited, 2010
Heat energy storage and cooling in buildings
121
Table 4.2 Some common working pairs suitable for thermal storage for heat powered sorption cooling systems Storage type
Working pairs
Adsorption
water/zeolite, water/silica gel, methanol/activated carbon and ammonia/activated carbon
Absorption
Water/lithium bromide, ammonia/water
Chemical reaction
Ammonia/inorganic salts
Mugnier and Goetz (2001) theoretically compared the storage capacities of 41 other working pairs that are potentially suitable for sorption or reaction cooling systems. They categorised these working pairs into three groups: absorption, adsorption and solid/gas reaction. Their results show that the solid/gas reaction group of working pairs have the highest thermal storage capacity in terms of Wh/kg (ranging from 84 Wh/kg to 233 Wh/kg) with the absorption working pairs second (ranging from 77 Wh/kg to 277 Wh/kg) and the adsorption working pairs third (ranging from 23 Wh/kg to 82 Wh/kg). PCMs with 85 Wh/kg storage capacities are only slightly better than the adsorption working pairs, but much worse than the other two. This is because all chemical thermal storage working pairs in the three groups involve liquid–vapour phase change of high latent heat, but the surface sorption mechanism potentially compromises the sorption capacity of the adsorption working pairs. Lahmidi et al. (2006) studied a commercially available powder of SrBr2·6H2O as a solid/gas working pair for thermal storage. The reactive solid grains were mixed with a chemically inert binder – expanded natural graphite. Their experimental results show that this working pair can deliver approximately 49 kW/m3 cooling power and 36 kW/m3 heating power. They pointed out that a thermal storage system based on this working pair is superior to a hot water storage tank in terms of storage capacity for a direct floor heating application: 250 kW/m3 of a SrBr2·6H2O working pair at 353 K against 52 kW/m3 of water between 353 K and 308 K. Chemical thermal storage is promising for building heating and cooling applications due to its potential high storage capacity and wide operating temperature range. With the development of the research on chemical thermal storage working pairs, more working pairs will appear for practical applications.
4.4.4 Heat transfer in heat storage materials Thermal energy storage density and storage capacity are very important specifications of a thermal energy storage system. In applications, how quickly the heat can be charged/discharged to/from a thermal energy storage system is equally significant, since a compact high thermal storage capacity is not
© Woodhead Publishing Limited, 2010
122
Materials for energy efficiency and thermal comfort in buildings
necessarily able to deliver high rates of thermal power. Contrarily, a high thermal storage density is likely to compromise it. This dynamic performance of thermal power delivery is closely associated with heat transfer within the heat storage materials – that is, high thermal power charge and discharge signify fast heat transfer within the storage materials. However, they do not come together naturally since most good, practical thermal energy storage materials, particularly those with high thermal density, do not have favourable thermal properties such as high thermal conductivity, low viscosity, etc. for heat transfer. Thus, measures have to be taken to improve heat transfer within the storage materials in order to achieve the desired high charging/ discharging rates from thermal energy storage systems. There are several ways to address this issue. For solid sensible heat storage materials, heat transfer can be improved by using smaller particles instead of larger ones to shorten the heat travel distance in the materials. The same method can also be applied to PCMs by encapsulating them into small units. Mixing PCMs with good thermal conducting materials such as powder of graphite can also enhance heat transfer. Recently, Ho and Gao (2009) investigated the thermophysical properties of nanoparticles-in-paraffin emulsion as a phasechange material. They emulsified alumina (Al2O3) nanoparticles in paraffin (n-octadecane) by means of a non-ionic surfactant. The experimental results show that both thermal conductivity and viscosity non-linearly increase with the mass fraction of the nanoparticles. The increase in thermal conductivity becomes significant at high temperatures. However, the increased viscosity is, by no means, advantageous for natural convection-dominated thermal storage applications. Khodadadi and Hosseinizadeh (2007) simulated the phase-change process of a nanofluid (water + copper nanoparticles) within a differently heated square cavity. The simulation results revealed that, with the addition of nanoparticles, the nanofluid froze faster than without, and that the freezing speed increased with the percentage of nanoparticles added. Both these works demonstrate the potential of nanoparticles in enhancing heat transfer in phase-change materials.
4.5
Thermal storage applications for building heating and cooling
Thermal storage materials can be used to improve the energy performance of a building with respect to building heating or cooling in different ways. Some of the applications, as discussed below, are easily implemented.
4.5.1 Structural thermal energy storage materials The indoor temperature of buildings constructed using lightweight materials can be easily influenced by the conditions outside, since these buildings have
© Woodhead Publishing Limited, 2010
Heat energy storage and cooling in buildings
123
low thermal masses and therefore low thermal capacities for heat storage. Even with good insulation, solar insolation through windows and glass doors can still be a significant source of overheating and thus processes such as air conditioning become necessary. This increases the energy consumption of the building. A current way of addressing such a problem is to incorporate PCMs into the structural materials of walls and ceilings. This development increases thermal storage capacities whilst maintaining the desired light weight, using a phase-change wallboard, for example. Common structural materials such as gypsum or concrete can be incorporated with PCMs. Both PCM incorporated gypsum and concrete materials have improved thermal storage capacities compared to those without. Nevertheless, PCM incorporated gypsum is superior to PCM incorporated concrete since only low percentages of PCM can be integrated into concrete when compared to gypsum (around 25%). Consequently, the resultant PCM–concrete composite has a lower latent heat capacity than its gypsum counterpart. Liu and Awbi (2009) and Kuznik and Virgone (2009) tested DuPontTM EnergainTM panels containing 60% micro-encapsulated paraffin and compared the results to wallboards without PCM incorporated. Their test results show that the PCM incorporated panels enhanced the natural convection of the air and had lower wall temperatures in the cooling period than the panels without. Thus, PCM incorporated wallboards are potentially very useful for improving the thermal storage capacity of existing buildings without the need for major work. Despite their promise, porous thermal storage composite materials such as PCM incorporated gypsum weaken over time. Endeavours to address this issue include the study by Li et al. (2009), whereby micro-encapsulated paraffin was incorporated into high-density polyethylene (HDPE)/wood flour rather than gypsum. The research claims that the use of HDPE/wood flour in place of gypsum results in a stronger composite and also that the addition of 8.8 wt% Micro-mist graphite into the paraffin increases the thermal conductivity of the storage material by 17.7%. Although the integration of composite PCM storage materials in building thermal storage applications is a promising advancement, the current technologies have far to go. There is still a pressing need for further improvements before they can be treated as conventional materials from a practical perspective.
4.5.2 Thermal energy storage materials for passive cooling The variation of temperature throughout the day can be exploited to provide buildings with ‘free cooling’. The term ‘free cooling’ refers to the storage of cold in the night when temperatures are low and the absorption of heat during the day when room temperatures are high. By incorporating cold
© Woodhead Publishing Limited, 2010
124
Materials for energy efficiency and thermal comfort in buildings
storage into ventilation systems, one can supply the building with ‘free cooling’. In such applications, any thermal storage material (be it sensible or phase change) can be used for the storage of cold. Zalba et al. (2004) studied and designed a four-module storage system using PCMs (RT25 and C22) to store and supply the free cooling. It was reported that the PCM storage system needs an extra 9% investment but uses 9.4 times less electrical power (equivalent to 3–4 years pay-off period) compared with similar cooling power conventional split refrigeration units. The effective transfer of heat between PCMs and the air is a persistent challenge when large quantities of PCM are involved in the case of free cooling systems. Turnpenny et al. (2000) proposed the use of heat pipes as a method of heat transfer and reported that a heat transfer rate of 40 W over a melt period of 19 hours was achieved when the temperature difference between the air and the PCM is 5 ºC. Their experiments were carried out using a heat pipe with fins extending 20 mm into PCM, leaving 49% of the PCM more than 20 mm from any fin. The authors believe that further extending the fins into the PCM can potentially increase the heat transfer rate. If a ventilation system is incorporated with ground thermal energy storage (where the earth is used as the sensible heat storage material), the provision of a stable air temperature all year round becomes a possibility. As an open system, fresh air can be supplied at a stable temperature to buildings, i.e., supplying cool air in summer and warm air in winter.
4.5.3 Thermal energy storage incorporated with active cooling/heating Thermal storage can also be incorporated with heat pump systems to avoid the extreme high or low temperature conditions that compromise the energy performance of the systems. By acting as a stabiliser of a heat source or sink, thermal storage can provide heat pumps with a more stable evaporating or condensing temperature all year round. This reduces the temperature difference upon which the heat pumps operate and thus reduces energy consumption. For this kind of application, the ground is an excellent thermal energy storage body. Nagano (2005) studied the use of the foundation piles of buildings as a medium with which to exchange heat with the earth. The example discussed in the report consists of a high-rise building, with a 2800 m2 floor area, supported by 51 steel piles with diameters ranging from 600 mm to 800 mm. Such steel piles provide an effective total of 240 m length for heat exchange with the earth and are able to handle 50 kW of heat. Compared with a gas powered cooling and heating system (a gas boiler plus cooling/ heating machine), the study concluded that the annual operating cost of this system was less than half of the gas powered one and had an annual CO2 emission that was approximately 63% of the gas powered one.
© Woodhead Publishing Limited, 2010
Heat energy storage and cooling in buildings
4.6
125
Sources of further information and advice
The following journals regularly contain technical papers on heat energy storage and cooling: Applied Energy, Applied Thermal Engineering, Building and Environment, International Communications in Heat and Mass Transfer and Solar Energy.
4.7
References
Bejan, A. (1993), Heat Transfer, John Wiley & Sons, Inc. Blundell, S. and Blundell, K. (2006), Concepts in Thermal Physics, Oxford University Press. Cengel, Y. and Boles, M. (1998), Thermodynamics: An Engineering Approach, 3rd edn, McGraw-Hill. Finn, C. (1993), Thermal Physics, 2nd edn, Chapman & Hall. Ho, C.J. and Gao, J.Y. (2009), Preparation and thermophysical properties of nanoparticlesin-parafin emulsion as phase change material. International Communications in Heat and Mass Transfer, 36, 460–470. Khodadadi, J.M. and Hosseinizadeh, S.F. (2007), Nanoparticle-enhanced phase change materials (NEPCM) with great potential for improved thermal energy storage. International Communications in Heat and Mass Transfer, 34, 534–543. Kuznik, F. and Virgone, J. (2009), Experimental assessment of a phase change material for wall building use. Applied Energy, 86, 2038–2046. Lahmidi, H., Mauran, S. and Goetz, V. (2006), Definition, test and simulation of a thermochemical storage process adapted to solar thermal systems. Solar Energy, 80, 883–893. Lane, G.A. (1980), Low temperature heat storage with phase change materials. International Journal of Energy Research, 5, 155–160. Li, J., Xue, P., Ding, W., Han, J. and Sun, G. (2009), Micro-encapsulated paraffin/ high-density polyethylene/wood flour composite as form-stable phase change material for thermal energy storage. Solar Energy Materials and Solar Cells, 93(10), 1761–1767. Liu, H. and Awbi, H. (2009), Performance of phase change material boards under natural convection. Building and Environment, 44, 1788–1793. Lovegrove, K. and Luzzi, A. (1996), Endothermic reactors for an ammonia based thermochemical solar energy storage and transport system. Solar Energy, 56, 361–371. Mugnier, D. and Goetz, V. (2001), Energy storage comparison of sorption systems for cooling and refrigeration. Solar Energy, 71, 47–55. Nagano, K. (2005), Development of the PCM floor supply air-conditioning system, in Paksoy, H. (ed.), Thermal Energy Storage for Sustainable Energy Consumption, Springer, 367–373. Turnpenny, J., Etheridge, D. and Ray, D. (2000), Novel ventilation cooling system for reducing air conditioning in buildings. Part I: testing and theoretical modelling. Applied Thermal Engineering, 20, 1019–1037. White, M. (1999), Properties of Materials, Oxford University Press. Zalba, B., Marin, J., Cabeza, L. and Mehling, H. (2004), Free cooling of buildings with phase change materials. International Journal of Refrigeration, 27, 839–849.
© Woodhead Publishing Limited, 2010
126
Materials for energy efficiency and thermal comfort in buildings
4.8 C p C v g G h hfg H m N P Q R S T u U v V W x
Appendix: Nomenclature specific heat under constant pressure, kJ/kg K specific heat under constant volume, kJ/kg K or kJ/(mol· K) specific Gibbs free energy or Gibbs function, kJ/kg Gibbs free energy or Gibbs function, kJ specific enthalpy, kJ/kg latent heat of evaporation or condensation, kJ/kg enthalpy, kJ mass of substance, kg number of particles pressure, Pa, N/m2 heat, kJ universal gas constant, kJ/(mol· K) entropy, kJ/K temperature, °C or K specific internal energy, kJ/kg internal energy, kJ specific volume, m3/kg volume, m3 work, kJ concentration of solution, % mass friction, kg/kg
Greek w r m g f
absolute humidity, kg/kg density, kg/m3 chemical potential, J/mol latent heat, kJ/kg relative humidity, %
Subscript 1,2.. state point a air f liquid g dry air m mixture v vapour w water vapour
© Woodhead Publishing Limited, 2010
5
Thermal comfort in buildings
K. P a r s o n s, Loughborough University, UK
Abstract: The basic principles of creating environments for thermal comfort are well understood. This chapter presents those principles and uses them to address the new challenge of specifying conditions for sustainable thermal comfort. Currently accepted methods and Standards are presented which include the predicted mean vote (PMV) and the predicted percentage dissatisfied (PPD) thermal indices. A description of behavioural models leads to the equivalent clothing index (IEQUIV) and a suggestion that it is not necessary to heat offices above 20 oC nor cool them below 25 oC. If this practice were followed it would save significant resources and make a step change in progress towards sustainable thermal comfort. It is concluded that while much can be done, our philosophical, technical and scientific understanding of sustainable thermal comfort is still in its infancy. Key words: sustainable, thermal, comfort, heat, cold.
5.1
Introduction
There are many ways of creating indoor environments that provide thermal comfort and the factors involved are generally well understood. The reduction of air temperature in an office during a heat wave using air conditioning systems can provide thermal comfort for the people in that office. The increase in air movement using fans or natural air flows, however, can also provide comfort even if the air temperature is not reduced. The conditions that provide thermal comfort are well understood, from a century of systematic laboratory and field research, involving studies in psychology, psychophysics, biophysics and physiology. However, the relationships among designing for thermal comfort and energy use, human behaviour, and sustainability have not been studied extensively and are not well understood. The principles for creating thermal comfort are a prerequisite to sustainable design. Use of the principles to achieve requirements for energy and sustainability is a subject of on-going investigation. Both the principles of thermal comfort and the practical design for thermal comfort in sustainable environments are addressed in this chapter.
5.2
Thermal comfort
Thermal comfort is a term that is generally regarded as a desirable or positive state of a person. It is used in relation to how warm or cold a person feels 127 © Woodhead Publishing Limited, 2010
128
Materials for energy efficiency and thermal comfort in buildings
and is clearly related to the environment a person occupies. There are many levels of discussion regarding the meaning and nature of thermal comfort and there was much activity and debate in the 1960s and 1970s on this topic (see McIntyre, 1980, for a review). Much has been achieved since 1970 in understanding the conditions that create thermal comfort. However, because of the need to take our understanding to a higher level in order to meet increased and new requirements, these discussions are again coming to the fore. A starting point is the generally accepted basic definition of thermal comfort from ASHRAE (1966) and now adopted internationally: ‘Thermal comfort is that condition of mind which expresses satisfaction with the thermal environment’. The emphasis is on a state of mind clearly linking thermal comfort with a ‘psychological’ response. So how do we know what state of mind a person is in? The obvious answer is that we ask them. Subjective scales for use in measuring thermal comfort are provided in Section 5.3. For most cases the definition above is acceptable. There is debate, however, about whether it is entirely correct. What if the state of mind expresses satisfaction but it is clear that the conditions could not be regarded as comfortable or even acceptable? If a person is not familiar with the concept of thermal comfort then he or she may not be disposed to report discomfort. Satisfaction may be expressed because dissatisfaction is not the state of mind. This could apply even where a person is sweating, sticky, hot and so on; a state of mind which expresses satisfaction but surely the person is not in thermal comfort. This should be distinguished from expression of satisfaction and hence implied thermal comfort due to expectation. The state of mind is then ‘uncomfortable’ but satisfaction is expressed because the person is not used to, nor expects, ‘any better’. A further group of people where it is difficult to interpret the definition is for those who may have a limited concept of comfort or an inability to express it. Babies, young children, people with mental disabilities and others, would generally not be able to express a condition of mind. An alternative definition may then apply as it is clear (at least reasonable to assume) that all people in thermal environments would regard certain conditions as undesirable and negative and others desirable and positive (i.e. whatever their condition of mind). The issue of whether the concept of thermal comfort is an international phenomenon is of interest if we are to specify optimal conditions for indoor environments worldwide. If the concept exists how is it expressed in terms of the culture and language of the population? It has generally been considered that the concept of thermal comfort does exist internationally and that conditions for thermal comfort can, for practical purposes, be assumed to be identical across the world. Arguments against this assumption have generally pointed to the likelihood, or natural expectation, that people in hot conditions would prefer ‘warm’ or higher temperature conditions for thermal
© Woodhead Publishing Limited, 2010
Thermal comfort in buildings
129
comfort than those that live in temperate or cold climates. In fact, evidence suggests that this is not the case and that although people who live in hot or cold climates are better able to survive heat or cold respectively, conditions for thermal comfort do not vary (Fanger, 1970; Parsons, 2003). In field studies of tropical climates it is often concluded that thermal comfort conditions are at higher temperatures than those for people who live in temperate climates. Supporting evidence often cites indoor temperatures which exist in buildings in tropical countries and assume that they are comfort temperatures. First, there is no reason why we can assume that these are comfort temperatures and second, even if people say they are satisfied, it may be for one of the reasons outlined above and probably if ‘actual’ comfort conditions were presented then this would be preferred. A less neutral and more positive concept related to thermal comfort is thermal pleasure. A contributor to good feng shui is a refreshing wind providing a stimulating and desirable environment. Thermal pleasure can also be found in cool temperatures compensated for by the heat of the sun. Such conditions are usually beyond thermal comfort. Thermal pleasure can also be found where a person who is cold moves to a warmer environment and a person who is hot moves to a cooler environment. This is a transient, short-lived phenomenon and after a few minutes pleasure will disappear as the person adapts to the new conditions. Designing for thermal pleasure therefore is a function of the interaction of the thermal environment with other factors and the recognition that environments are dynamic.
5.3
Measurement of thermal comfort
One of the best ways of determining whether a group of people are comfortable is to ask them. Thermal sensation, comfort, pleasure, pain, as well as behavioural responses, are all psychological phenomena. There have been many useful studies to ‘correlate’ physical conditions and physiological responses with psychological responses. However, no model provides a more accurate prediction than measuring psychological responses directly. Methods for measuring psychological responses range from psychophysical techniques (method of limits, method of magnitude estimation, multidimensional scaling, etc. – see Guildford, 1954) and simple (seven-point) scales often used in laboratory experiments, to the integration of techniques into questionnaires for practical surveys as well as behavioural measures.
5.3.1 Subjective measures There are a number of subjective scales which have been used in the assessment of thermal environments; the most common of these are the seven-point scales of Bedford (1936) and ASHRAE (1966) (see Table 5.1).
© Woodhead Publishing Limited, 2010
130
Materials for energy efficiency and thermal comfort in buildings Table 5.1 Scales of warmth sensation, from Bedford (1936) and ASHRAE (1966) Bedford comfort scale
ASHRAE sensation scale
Much too warm Too warm Comfortably warm Comfortable Comfortably cool Too cool Much too cool
Hot Warm Slightly warm Neutral Slightly cool Cool Cold
7 6 5 4 3 2 1
7 6 5 4 3 2 1
The form and method of administering the scales is important. For example, a continuous form of the scale would be to draw a line through all points. This would allow subjects to choose points between ratings (e.g. between cool and cold, a rating of 1.6 on the ASHRAE scale, for example). In analysis of results this would enable parametric statistics to be used. However, maybe the investigator does not consider data ‘strong enough’ for this and is prepared only to use ordinal data (ranks) and non-parametric statistics. These and other points are of importance and for further information the reader is referred to a text on the design and analysis of surveys – e.g. Moser and Kalton (1971) – and on the use of subjective assessment methods – e.g. Sinclair (1990) as well as ISO DIS 28802 (2009) which describes scales for use in an environmental survey. The ‘psychological’ interaction when the scale is administered may also influence results. Subjects are usually given the scale and asked to tick the place which represents ‘how they feel now’, for example. It is important to avoid ambiguity which may lead to a person providing their own interpretation, e.g. what the environment is generally like, or how other people may perceive it, etc. Other issues include range effects – the range provided, e.g. hot to cold, influences the judgement – and leading questions ‘you are uncomfortable aren’t you?’. Sinclair (1990) identifies the following important issues to be considered when constructing questionnaires: question specificity, language, clarity, leading questions, prestige bias, embarrassing questions, hypothetical questions and impersonal questions. Other issues include whether knowledge of results is given – for example, if responses are requested over time, is the subject informed of previous ratings he made? – and whether the ratings are given in the presence of others. Investigations involving subjective measures therefore must be carefully planned. It should be emphasized that although there are many pitfalls, most can be relatively easily overcome and the use of simple subjective methods allows easy collection of important data, which can prove invaluable in the measurement of psychological responses. ISO 10551 (1995) presents the principles and methodology for the
© Woodhead Publishing Limited, 2010
Thermal comfort in buildings
131
construction and use of scales for assessing the environment. Scales are divided into two types: personal and environmental. Those related to the personal thermal state may be perceptual – how do you feel now? (e.g. hot), affective – how do you find it? (e.g. comfortable) and preference – how would you prefer to be? (e.g. warmer). Those related to the environment fall into two types: acceptance (e.g. is the environment acceptable?) and tolerance (e.g. is the environment tolerable?) An interesting point for an international standard is translation between languages, since in French, for example, one cannot easily use together ‘warm’, ‘hot’ and ‘very hot’. The fundamental principles and psychological phenomena, however, apply over all nationalities although language and cultural difference (in some cultures subjects may be reluctant to express dissatisfaction) will be important. The selection of subjective scales will depend upon the population under investigation and an initial investigation may be necessary to identify meaningful dimensions. For example, in the investigation of the thermal comfort of clothing (Hollies et al., 1979), the seven-point thermal sensation scales are in general use; however, scales of stickiness, wetness, etc., are used for specific applications. The construction and use of simple questionnaires used in a thermal survey are given in Parsons (2003) and ISO DIS 28802 (2009) (Environmental survey).
5.3.2 Behavioural and observational measures Thermal environments can affect the behaviour of individuals (move about, curl up, put on or take off clothing, become aggressive or quiet, change thermostat setting, etc.). This behaviour can be observed and aspects of it quantified and hence measured. A number of studies have observed the behaviour of householders in controlling internal temperatures by measuring temperatures in the homes (e.g. Weston 1951; Humphreys, 1978). The causes are not always clear. They may be related to increased heating costs to the preference for wearing lighter clothing, for example. More direct observations of behaviour have been made on schoolchildren using time-lapse photography and two-way mirrors. For these methods observer interference is of great importance and should be carefully considered (Humphreys, 1972; Wyon and Halmberg, 1972). Other behavioural measures could include the occupational density of a room (where there is choice) or a measure of accidents or critical incidents. Drury (1990) provides a description of direct observational methods that he says have a high degree of face validity but a low degree of experimental control. For example, even if behavioural measures are correlated with thermal conditions, it cannot be concluded that thermal conditions are the (sole) cause. If the establishment of causality is not important, however, then observation of behaviour provides a useful measure. Behavioural measures can provide a
© Woodhead Publishing Limited, 2010
132
Materials for energy efficiency and thermal comfort in buildings
method of observing both quantitative and qualitative ‘measures’ with little interference with what is being observed.
5.4
The thermal index: an assessment technique
A useful tool for describing, designing and assessing thermal environments is the thermal index. The principle is that factors that influence human response to thermal environments are integrated to provide a single index value. The aim is that the single value varies as human response varies and can be used to predict the effects of the environment. A thermal comfort index, for example, would provide a single number that is related to the thermal comfort of the occupants of an environment. It may be that two different thermal environments (i.e. with different combinations of various factors such as air temperature, air velocity, humidity and activity of the occupants) have the same thermal comfort index value. Although they are different environments, for an ideal index, identical index values would produce identical thermal comfort responses of the occupants. Hence environments can be designed and compared using the comfort index. A useful idea is that of the standard environment. Here the thermal index is the temperature of a standard environment that would provide the ‘equivalent effect’ on a subject as would the actual environment. Methods of determining equivalent effect have been developed. One of the first indices using this approach was the effective temperature (ET) index (Houghton and Yagloglou, 1923). The ET index was, in effect, the temperature of a standard environment – air temperature equal to radiant temperature, still air, 100% relative humidity for the activity and clothing of interest – which would provide the same sensation of warmth or cold felt by the human body as would the actual environment under consideration.
5.5
Thermal comfort indices
5.5.1 The six basic ‘parameters’ It is generally agreed that any specification of thermal comfort conditions must consider the six basic parameters (variables). These are air temperature, radiant temperature, humidity, air velocity (i.e. the four environmental factors) and the clothing insulation and heat produced by the activity of a person (i.e. the two personal factors). An important point is that any and all of the six factors can influence thermal comfort and that it is the integrated influence of all of the six factors that determines thermal comfort response. ISO 7726 (1985) provides information concerning specification of instruments for the measurement of the environmental factors. ISO 8996 (1990) provides methods for the estimation of heat production by a person for different activities. 1
© Woodhead Publishing Limited, 2010
Thermal comfort in buildings
133
Met is defined as the heat produced by a sedentary person and is given the value of 58 Watts produced for every square metre of the body surface area (i.e.1.0 Met = 58 Wm–2. Higher activity levels have higher values. ISO 9920 (1992) provides information concerning the thermal properties of clothing. For dry insulation a value of 1 Clo is defined as providing an insulation of 0.155 m2 K W–1 (1.0 Clo often regarded as the insulation of a typical business suit; 0 Clo is for a naked person, 0.6 Clo light clothing and so on).
5.5.2 Fanger (1970) The most significant landmark in thermal comfort research and practice was the publication of the book Thermal Comfort by Fanger (1970), which outlines the conditions necessary for thermal comfort and methods and principles for evaluating and analysing thermal environments with respect to thermal comfort. Fanger considered that existing knowledge of thermal comfort was inadequate and unsuitable for practical application, and his book is based upon research undertaken at the Technical University of Denmark and at Kansas State University, USA. The methods that he developed are now the most influential and widely used throughout the world. The reason for this success has been the consideration of the ‘user requirements’. He had the vision to recognize that it is the combined thermal effect of all (six basic parameters) physical factors which determines human thermal comfort, and that a practical method was required which could predict conditions for ‘average thermal comfort’ and consequences (in terms of thermal discomfort, e.g. percentage of people dissatisfied) of exposure to conditions away from those for ‘average thermal comfort’.
5.5.3 The comfort equation Fanger (1970) defines three conditions for a person to be in (whole-body) thermal comfort: ∑ the body is in heat balance; ∑ sweat rate is within comfort limits; and ∑ mean skin temperature is within comfort limits. A fourth condition is the absence of local thermal discomfort (e.g. caused by draught). The objective was to produce a comfort equation requiring input of only the six basic parameters and based on the above three conditions, to calculate conditions for thermal comfort. This was achieved using a rational analysis of heat transfer between the clothed body and the environment and experimental research. Fanger’s original work was not in SI units so the SI version presented below is taken from Olesen et al. (1982), ASHRAE (1989) and ISO 7730 (2005).
© Woodhead Publishing Limited, 2010
134
5.5.4
Materials for energy efficiency and thermal comfort in buildings
Heat balance
Fanger’s conceptual heat balance equation is: H – Ed – Esw – Ere – L = K = R + C
5.1
where a description of terms used is given in Table 5.2. Heat is generated in the body and lost at the skin and from the lungs. It is transferred through clothing where it is lost to the environment. Logical considerations, reasonable assumptions, and a literature review provide equations for each of the terms such that they can be calculated from the six basic parameters: air temperature (ta); mean radiant temperature (tr); partial vapour pressure (Pa pv); air velocity (v); clothing insulation (Icl); and metabolic heat production (M–W, where M is metabolic rate and W is external work). Table 5.3 provides the equations for the components of the Table 5.2 Terms used in the predicted mean vote (PMV) H Ed Esw Ere L K R C
= = = = = = = =
Internal heat production in the human body Heat loss by water vapour diffusion through skin Heat loss by evaporation of sweat from skin surface Latent respiration heat loss Dry respiration heat loss Heat transfer from skin to outer surface of clothing Heat transfer by radiation from clothing surface Heat transfer by convection from clothing surface
Source: Comfort equation of Fanger (1970) Table 5.3 Equations for components of the heat balance equation used by Fanger (1970) in determining the PMV thermal comfort equations (see Table 5.2 for terms) H=M–W Ed = 3.05 ¥ 10–3(256ts – 3373 – Pa) ts = tsk,req i.e. for thermal comfort = 35.7 – 0.0275H Esw = Ersw,req i.e. for thermal comfort = 0.42(M – W – 58.15) L = 0.0014M(34 – ta) Ere = 1.72 ¥ 10–5M(5867 – Pa) K=
(t s – tcl ) 0.155Icl
R = 3.96 ¥ 10–8fcl [(tcl + 273)4 – (tr + 273)4] C = fclhc(tcl – ta) Note: Units for all components: W m–2; Pa in Pascals; temperatures in °C and lcl in m2 KW–1.
© Woodhead Publishing Limited, 2010
Thermal comfort in buildings
135
heat balance equation to determine the PMV thermal comfort equations. tcl is the mean surface temperature of clothing and exposed skin; ts is mean skin temperature and fcl is a non-dimensional term for the ratio of the surface area of the clothed person to the surface area of the naked person; hc is the convective heat transfer coefficient in Wm–2K–1.
5.5.5 Sweat rate and skin temperature for comfort Heat balance is a necessary but not sufficient condition for comfort. The body can be in heat balance but uncomfortably hot due to sweating or uncomfortably cold due to vasoconstriction and low skin temperatures. Skin temperatures and sweat rates required for comfort tsk,req, and Ersw,req, depend upon activity level. Rohles and Nevins (1971) provide the following equations:
tsk,req = 35.7 – 0.0275(M – W) °C
Ersw,req = 0.42(M – W – 58.15) Wm–2
5.2
By substituting tsk,req and Ersw,req terms into the heat balance equation, the method of combination of the six basic parameters which produce thermal comfort can be expressed in a comfort equation (see Fanger, 1970; Parsons, 2003).
5.5.6 Predicted mean vote (PMV) and predicted percentage dissatisfied (PPD) To provide a method for evaluating and analysing thermal environments, Fanger made the proposal that the degree of discomfort will depend on the thermal load (L). This he defined as ‘the difference between the internal heat production and the heat loss to the actual environment for a man hypothetically kept at the comfort values of the mean skin temperature and the sweat secretion at the actual activity level’. In comfort conditions the thermal load will be zero. For deviations from comfort the thermal sensation experienced will be a function of the thermal load and the activity level. For sedentary activity, Nevins et al. (1966) and Fanger (1970) provide data and McNall et al. (1968) provide data for four activity levels (from 1396 subjects exposed for 3 hours in 0.6 Clo KSU uniform). This provided an equation for the predicted mean vote (PMV) of a large group of subjects if they had rated their thermal sensation in that environment on the following scale:
© Woodhead Publishing Limited, 2010
136
Materials for energy efficiency and thermal comfort in buildings
sensation
PMV
Hot Warm slightly warm Neutral slightly cool Cool Cold
+3 +2 +1 0 –1 –2 –3
PMV = (0.303e–0.036M + 0.028 ¥ [(M – W) – 3.05 ¥ 10–3{5733 – 6.99(M – W)–Pa} – 0.42{(M – W) – 58.15} – 1.7 ¥ 10–5M(5867 – Pa) – 0.0014M(34 – ta) – 3.96 ¥ 10–8fcl[(tcl + 273)4 – (tr + 273)4] – fclhc(tcl – ta)}]
5.3
where: tcl = 35.7 – 0.028(M – W) – 0.155Icl[3.96 ¥ 10–8 fcl ¥ {(tcl + 273)4 – (tr + 273)4} + fclhc(tcl – ta)]
5.4
hc = max(2.38(tcl – ta)0.25, 12.1 v) fcl = 1.0 + 0.2Icl for Icl ≤ 0.5
5.5
= 1.05 + 0.1Icl for Icl > 0.5 where Icl values are in units of Clo. Fanger (1970) presents tables showing PMV values for 3500 combinations of the variables. These are now unnecessary as the calculations of PMV can easily be made on a personal computer; see ISO 7730 (2005) and Parsons (1993). The predicted percentage of dissatisfied (PPD) provides practical information concerning the number of potential complainers. The data of nevins et al. (1966), Rohles (1970) and Fanger (1970) provided a relationship between the percentage of dissatisfied and the mean comfort vote (see Fig. 5.1 and ISO 7730, 2005): PPD = 100 – 95exp(–0.03353PMV4 – 0.2179PMV2)
5.6
Fanger (1970) describes a method for the use of the PMV and PPD in practical applications and includes examples involving an analysis of a large room and the use of a thermal non-uniformity index, lowest possible percentage of dissatisfied (LPPD), indicating the ‘best’ that can be achieved by changing the average PMV value in the room only – by changing average air temperature, for example – and hence indicating where specific areas of the room require attention.
© Woodhead Publishing Limited, 2010
Thermal comfort in buildings
Predicted percentage dissatisfied (PPD)
100%
Cold Cool
Slightly Neutral cool
Slightly warm
Warm
Hot
2
3
137
10 5
1 –3
–2
–1 0 1 Predicted mean vote (PMV)
5.1 Relationship between the PMV and the PPD.
Data to allow the determination of some PMV and PPD values are provided in Tables 5.4, 5.5, and 5.6.
5.6
International Standards and thermal comfort
Optimum indoor air temperatures have often been the subject of debate, and suggested limit or guidance values for buildings have been proposed over many years, by a number of professional institutions and in legislation. There is an increasing international interest in providing guidance to ensure protection and good practice in areas where people are exposed to hot, moderate and cold environments and there has been recognition that air temperature is only one component of a human thermal environment. The requirements of regional (e.g. European) and international (global) markets and the recognition that systems, services and products should be designed for human use have raised the profile of ergonomics and led to a proliferation of ISO standards, including those in the area of the ergonomics of the thermal environment. These include thermal comfort and are described below. For full details and practical applications the reader is referred to the original Standards. ISO 7730 (2005) provides an analytical method for assessing moderate environments and is based on the predicted mean vote and predicted percentage of dissatisfied (PMV/PPD) index, and on criteria for local thermal discomfort. If the responses of individuals or specific groups are required, then subjective measures should be used (ISO 10551, 1995). © Woodhead Publishing Limited, 2010
138
Materials for energy efficiency and thermal comfort in buildings
Table 5.4 Examples of estimates of clothing insulation values (Icl) for use in the PMV thermal equation of Fanger (1970) Clothing ensemble
Clo
m2KW–1
Naked
0.0
0.0
Shorts
0.1
0.016
Typical tropical clothing outfit Briefs (underpants), shorts, open neck skirt with short sleeves, light socks and sandals
0.3
0.047
Light summer clothing Briefs, long lightweight trousers, open neck shirt with short sleeves, light socks and shoes
0.5
0.078
Working clothes Underwear, cotton working shirt with long sleeves, working trousers, woollen socks and shoes
0.8
0.124
Typical indoor winter clothing combination Underwear, shirt with long sleeves, trousers, sweater with long sleeves, heavy socks and shoes
1.0
0.155
Heavy traditional European business suit Cotton underwear with long legs and sleeves, shirt, suit comprising trousers, jacket and waistcoat (US vest), woollen socks and heavy shoes
1.5
0.233
Table 5.5 Examples of estimates of metabolic rates (M) for use in the PMV thermal comfort equation of Fanger (1970) Activity
Met
Wm–2
Lying down
0.8
47
Seated quietly
1.0
58
Sedentary activity (office, home, laboratory, school)
1.2
70
Standing, relaxed
1.2
70
Light activity, standing (shopping, laboratory, light industry)
1.6
93
Medium activity, standing (shop assistant, domestic work, machine work)
2.0
116
High activity (heavy machine work, garage work)
3.0
175
5.6.1 ISO 7730: Moderate Thermal Environments – Determination of the PMV and PPD indices and specification of the conditions for thermal comfort This standard considers whole-body thermal sensation and local thermal discomfort caused by draughts. It is based on the predicted mean vote
© Woodhead Publishing Limited, 2010
Thermal comfort in buildings
139
Table 5.6 Predicted mean vote (PMV) values from Fanger (1970). Assume RH = 50%; still air and ta = tr. PMV: +3, hot; +2, slightly warm; +1, warm; 0, neutral; –1, slightly cool; –2, cool; –3, cold ta = tr
lcl (Clo) 0.1
0.3
0.5
0.8
1.0
1.5
2.0
M = 1 Met; var = 0.1 ms 10 12 14 –2.5 16 –2.5 –1.9 18 –1.9 –1.4 20 –2.3 –1.3 –0.9 22 –2.3 –1.5 –0.7 –0.3 24 –2.3 –1.4 –0.8 –0.1 0.2 26 –1.2 –0.5 0.0 0.6 0.8 28 –0.1 0.4 0.8 1.2 1.4 30 1.0 1.3 1.6 1.8 1.9 32 2.0 2.2 2.3 2.4 2.5
–2.2 –1.8 –1.4 –1.0 –0.5 –0.1 0.4 0.8 1.2 1.7 2.1 2.6
–1.4 –1.0 –0.7 –0.3 0.0 0.4 0.8 1.1 1.5 1.9 2.3 2.6
M = 1.2 Met; var = 0.1 ms–1 10 12 –2.8 14 –2.3 16 –2.8 –1.8 18 –2.9 –2.1 –1.2 20 –2.2 –1.5 –0.7 22 –2.3 –1.4 –0.8 –0.2 24 –1.4 –0.7 –0.2 0.3 26 –0.5 0.1 0.4 0.8 28 0.4 0.8 1.1 1.3 30 1.3 1.5 1.7 1.8 32 2.0 2.1 2.2 2.3
–2.7 –2.2 –1.8 –1.3 –0.8 –0.4 0.1 0.6 1.0 1.5 1.9 2.3
–1.6 –1.2 –0.9 –0.5 –0.1 0.2 0.6 1.0 1.4 1.7 2.1 2.4
–0.9 –0.6 –0.3 0.0 0.3 0.6 0.9 1.3 1.6 1.9 2.2 2.4
M = 1.6 Met; var = 0.1 ms–1 10 12 –2.6 14 –2.9 –2.1 16 –2.4 –1.7 18 –2.8 –1.8 –1.2 20 –2.1 –1.3 –0.7 22 –1.4 –0.7 –0.2 24 –0.7 –0.2 0.2 26 0.0 0.4 0.7 28 0.7 1.0 1.2 30 1.4 1.6 1.7 32 2.1 2.2 2.2
–1.5 –1.2 –0.9 –0.5 –0.2 0.2 0.5 0.8 1.2 1.6 1.9 2.3
–0.7 –0.4 –0.2 0.1 0.4 0.6 0.9 1.2 1.5 1.8 2.0 2.3
–0.2 0.0 0.3 0.5 0.7 0.9 1.2 1.4 1.6 1.9 2.1 2.4
–1
–2.0 –1.6 –1.3 –0.9 –0.5 –0.1 0.3 0.7 1.1 1.5 1.9 2.3
(PMV) and the predicted percentage of dissatisfied (PPD) indices (Fanger, 1970), and more recent work concerning draughts (Olesen, 1985; Fanger et al., 1989).
© Woodhead Publishing Limited, 2010
140
Materials for energy efficiency and thermal comfort in buildings
The PMV is the predicted mean vote of a large group of persons, on the following thermal sensation scale, if they had been exposed to the thermal conditions under assessment.
+3 +2 +1 0 –1 –2 –3
hot warm slightly warm neutral slightly cool cool cold
The PMV is calculated from the air temperature, mean radiant temperature, humidity and air velocity of the environment and estimates of metabolic rate and clothing insulation. It is derived from a heat balance equation for the human body combined with empirically determined equations which define sweat rates and mean skin temperatures which are within comfort limits. The equation is provided in Section 5.5.4 above. It is based on data from the exposure of 1300 subjects to various thermal environments. The draught rating (DR) is expressed as the percentage of people to be bothered by draughts, where
DR = (34 – ta)(v – 0.05)0.62(0.37vTu + 3.14)
5.7
where ta is local air temperature (°C), v is local mean air velocity (ms–1), Tu is local turbulence intensity (%) defined as the ratio of the standard deviation of the local air velocity to the local mean air velocity. The DR model is based on experiments on 150 human subjects for the following range of conditions: ∑ ∑ ∑
ta : 20–26 °C v : 0.05–0.4 ms–1 Tu: 0–70%
It applies to people performing mainly sedentary activity with whole-body sensations close to neutral. Risk of draught is lower at higher activities and if people are warmer than neutral. Thermal comfort is defined in the standard as ‘that condition of mind which expresses satisfaction with the thermal environment’. Dissatisfaction may be caused by whole-body or local discomfort. An annex (included, but labelled as not part of the standard) provides guidance in terms of levels of dissatisfaction. This includes dissatisfaction caused by whole-body discomfort and by draughts and other local effects (e.g. thermal gradients, asymmetric radiation, etc.). The Standard also considers the long-term thermal comfort performance of buildings and also provides guidance on appropriate conditions for different quality and spaces. Tables of metabolic rate and clothing
© Woodhead Publishing Limited, 2010
Thermal comfort in buildings
141
insulation values are included. For more detailed estimates the user can use ISO 8996 (1990) and ISO 9920 (1992). A computer program is provided to allow ease of calculation and efficient use of the standard.
5.6.2 ISO 7726: Thermal Environment – Instruments and methods for measuring physical quantities This Standard provides definitions of the basic parameters (air temperature, mean radiant temperature, humidity, air velocity) and derived parameters (natural wet bulb temperature, globe temperature). It also provides methods of measurement and specifications of measuring appliances. No specific instrument is standardized, only specifications. The Standard can therefore serve as a guide to manufacturers of instruments as well as specifying measuring requirements, in a contract between investigator and a client.
5.6.3 ISO 10551: Assessing the influence of the thermal environment using subjective judgement scales ISO 10551 (1995) presents the principles and methodology behind the construction and use of subjective scales, and provides examples of scales that can be used to assess thermal environments (see Table 5.7). A practical example and a discussion of methods of data analysis are provided. The principle of the Standard is to provide background information to allow ergonomists to construct and use subjective scales as part of the assessment of thermal environments.
5.7
Behavioural thermoregulation, thermal comfort and the adaptive model
People adapt to preserve comfort. When there is a ‘heat wave’ in the United Kingdom, enquiries are often received (from the press, public, etc.) on how to ‘keep cool’ in the hot conditions. Advice in the context of the six basic parameters could be to reduce clothing, increase air movement using fans, Table 5.7 Subjective scales considered in ISO 10551 (1995) Judgement
Example
Related to
Perceptual Affective Thermal preference Personal acceptance Personal tolerance
How do you feel now? (e.g. hot) How do you find it? (e.g. comfortable) How would you prefer to be? (e.g. warmer) Is the environment acceptable/unacceptable? Is the environment tolerable?
Personal Thermal State Environment
© Woodhead Publishing Limited, 2010
142
Materials for energy efficiency and thermal comfort in buildings
stay in the shade and be inactive. In extreme cases take a cool bath. It became clear, however, that there are simpler solutions based upon a paradigm shift in thermal comfort from that of traditional laboratory and field research. Cool places provide the opportunity to avoid becoming uncomfortably hot. People are not passive receptors of discomfort; if the opportunity is available to them they can take action including moving to more comfortable surroundings. The most effective form of thermoregulation to ensure survival, comfort and performance is classically known as behavioural thermoregulation. Moving to more desirable thermal conditions, adjusting clothing, seeking shelter, opening windows, changing posture, cuddling, lighting of fires, switching on air conditioners or fans, and more are all examples of behavioural thermoregulation. The profound change in the six basic parameters due to behavioural thermoregulation demonstrates the potential of behavioural thermoregulation and emphasizes the continuous dynamic interaction between people and their thermal environments. Although it has always been accepted that people are not passive, little account has been taken of human behaviour in design and assessment for thermal comfort. Attempts to influence accepted methods for the design and assessment of thermal comfort have used the term ‘adaptive modelling’ and proposals to use adaptive models of thermal comfort have been discussed for over forty years. The term ‘adaptive’ is unfortunate because it implies longer term, even evolutionary adaptation; however, it is now widely used in the context of thermal comfort and although requiring more stringent definition, it does not seem to cause confusion. Early ‘adaptive modellers’ include Auliciems (1981) from Australia and Humphreys and Nicol (1970) from the United Kingdom. The drive for adaptive modelling has continued with researchers from Australia, the United Kingdom, and the United States involving theoretical issues and worldwide field studies. The debate is ongoing; however, the ASHRAE (1997) global database of thermal comfort field experiments and associated adaptive model (de Dear, 1998; de Dear and Brager, 1998, 2002) and the interest of the International Standards Organization (ISO) ensured that adaptive models are being given serious consideration. Clearly if we are to improve our understanding of ‘adaptive modelling’ there needs to be rigorous scientific investigation of this area based on the method of null hypothesis. However, the most important point about behavioural or adaptive modelling is the paradigm shift and the new opportunities that it affords to develop our knowledge of thermoregulation.
5.8
Equivalent clothing index (IEQUIV)
In any environment there will be opportunity to adapt to maintain thermal comfort and these adaptive adjustments (behaviours) can take many forms and can occur in combination (e.g. adjust clothing, change activity, open a
© Woodhead Publishing Limited, 2010
Thermal comfort in buildings
143
window, change posture). Each of the actions and their combination will have an effect on human heat exchange. It is therefore possible to represent these effects in terms of the equivalent effect of changing one of the parameters in the heat balance equation. This could be any of the six basic parameters; however, a convenient approach would be to relate the total effect of all adaptive behaviour to the equivalent effect of adjusting clothing. An equivalent clothing index (IEQUIV) can be described as follows. The equivalent clothing index (IEQUIV) is the clothing insulation that would give equivalent thermal comfort to people with no adaptation as the thermal comfort of people who adapt to their thermal conditions. A group of people initially wearing 1.0 Clo who change clothing, change activity, change posture and open a window to maintain a neutral thermal sensation may have an equivalent clothing index value of 0.2 Clo, where 0.2 Clo would represent the clothing insulation required to maintain a neutral thermal sensation in the original conditions. The total of all adaptive behaviour therefore summates to a reduction of 0.8 Clo. The equivalent clothing index value can then be substituted into the PMV equation, instead of the clothing insulation value, to give a PMV that takes account of adaptive behaviour. Table 5.8 shows a possible relationship between adaptive opportunity and IEQUIV for a person dressed in 1.0 Clo.
IEQUIV = ISTART – (IADJ ¥ ISTART) in the heat
IEQUIV = ISTART + (IADJ ¥ ISTART) in the cold
5.8
where Istart is the clothes worn before adaptation and IADJ is the change in clothing that would have equivalent effect on thermal comfort to the sum of all adaptive measures. For cases where no adaptation is possible, then clothing, posture, activity, physical environment (e.g. windows) cannot be adjusted (IADJ = 0). Therefore the equivalent clothing is the actual clothing worn at the beginning of the exposure period (IEQUIV = ISTART). For maximum adaptation in the heat, it will be possible to take off all clothing as well as making other adaptive adjustments (open windows, reduce activity). For these conditions it may be useful to adjust parameters separately (e.g. metabolic rate) in the rational index (e.g. PMV) as well as using IEQUIV = 0. In these circumstances, thermal Table 5.8 IADJ values for a range of adaptive opportunities Adaptive opportunity
IADJ
Minimum Low Medium High Maximum
0 0.25 0.5 0.75 1.0
© Woodhead Publishing Limited, 2010
144
Materials for energy efficiency and thermal comfort in buildings
comfort is an unusual concept and, in practice, adaptive effects greater than taking off all clothing would be unusual. It may therefore be reasonable to assume IEQUIV = 0 is a minimum practical value. A similar argument applies for IEQUIV in cold conditions where doubling of clothing insulation is a realistic maximum with more detailed analysis required for special cases. It should be noted that IADJ may be different for hot conditions than for cold conditions as different adaptation may be required; for example, if opening windows is the only adaptive opportunity, then IADJ may be ‘medium’ in hot conditions but ‘minimum’ in the cold, etc.
5.9
Equivalent clothing index, the comfort temperature range and temperature limits in offices
Although a rational index such as the PMV provides a versatile tool with which to determine thermal comfort conditions in terms of the six basic parameters (variables), there is a requirement to provide temperature ranges within which people can maintain comfort. Suppose people in a building wear 1.0 Clo, perform sedentary activity in conditions with no radiant load (ta = tr), and vapour pressure of 1.0 kPa in still air. They can reduce their clothing but cannot increase it, they can move around and open windows. We could assess the adaptive opportunity as high in the heat and low in the cold. A PMV of 0 (neutral) is then obtained at 24 °C for IEQUIV = ISTART = 1.0 Clo; 28.5 °C for IEQUIV = 0.25 Clo and 22.8 °C for IEQUIV = 1.25 Clo. This provides a comfort temperature range of 22.8 °C to 28.5 °C. If a range between +1 (slightly warm) and –1 (slightly cool) is regarded as acceptable then an acceptable range would be 18.2 °C to 30.5 °C (see Table 5.6). The PMV is an example of a rational index and its validity does not affect the principles of the above. The IEQUIV method is a behavioural adjustment which is a practical way forward. It is preferable to ‘expectancy’ adjustments where statements such as, ‘It is what they are used to and do not expect better’, border on the unethical and, in any case, are flawed as if people claim comfort at 30 °C, how do we know that they would not also claim comfort at PMV = 0 (e.g. 24 °C).
5.10
Sustainable thermal comfort
If we consider sustainability to be the use of resources in such a way that they do not become exhausted, or even reduced at all, this will provide a context for achieving sustainable thermal comfort. We have seen in this chapter that there are many ways of attaining thermal comfort. A useful starting point is to consider the many combinations of air temperature, radiant temperature, humidity, air velocity, clothing and activity that will create
© Woodhead Publishing Limited, 2010
Thermal comfort in buildings
145
comfort conditions. Practical constraints and context will leave a subset of the conditions to provide thermal comfort in any design or application. It is reasonable to assume that a further subset of those conditions will provide sustainable thermal comfort. Knowledge of what constitutes a sustainable ‘system’ or environment is in its infancy and enthusiasm for ‘saving the planet’ has not always been based upon ‘solid science’, clear rationale and evidence. By definition the degree of sustainability requires a view on resources used, resources available and the dynamics of the relationship between them. To specify conditions for sustainable thermal comfort therefore requires much more analysis and research than is currently available. There are, however, practical suggestions for ‘good housekeeping’ that can greatly reduce the use of resources and energy and decrease carbon production. Two obvious measures towards sustainable thermal comfort are to reduce use of resources due to technological control (e.g. air conditioning) and design environments that make it less resource intensive to create thermal comfort and complement, for example, human behaviour and adaptive opportunity to allow individuals to achieve thermal comfort. The use of the IEQUIV index to take account of adaptive opportunities provides a rational approach to specifying thermal comfort. If the IEQUIV index is used in conjunction with the PMV thermal comfort model then a range of conditions can be found within which thermal comfort can be maintained. This simple approach can have dramatic effects in saving resources. For example, there is a tendency for people to over-react when faced with hot or cold conditions. In a heat wave, air temperatures are reduced to levels unnecessary for the achievement of thermal comfort when simple measures such as air movement or reduced clothing (e.g. taking off a tie) could be used. Indeed, such is the over-reaction that complaints of being too cold in rooms, due to air conditioning, are not uncommon when the outside weather is hot. There seems to be an over-reaction in this scenario which could significantly contribute to an increase in total cooling demand during a heat wave. In cold outdoor conditions it is not necessary to overheat a space when a simple increase in clothing can provide comfort. Parsons (2002) demonstrated that people could maintain comfort at below 20 oC air temperature using clothing, although local effects (particularly among females) suggested below 19 oC started to cause discomfort. The over-reliance on technology to provide thermal comfort solutions leads to high energy costs, due to excessive cooling with air conditioning or unnecessary use of heating; this can be considered poor housekeeping and represents an unsustainable approach to achieving thermal comfort. There are clearly limits to adaptive behaviour for thermal comfort. However, a significant saving in energy and resources could be made and sustainable thermal comfort provided if we did not heat offices above 20 oC
© Woodhead Publishing Limited, 2010
146
Materials for energy efficiency and thermal comfort in buildings
or cool them below 25 oC. This can be demonstrated by an IEQUIV and PMV analysis (see Table 5.6). For more detailed values a full analysis, involving all six parameters, is required. However, cooling below 20 oC begins to cause local discomfort and above 25 oC an unacceptable reduction in clothing, or a tendency to become warm and sticky. Using simple measures, some major savings can already be made and help move towards sustainable thermal comfort. Further work is needed to our philosophical approach and technical and scientific understanding.
5.11
References
ASHRAE (1966), Thermal comfort conditions, ASHRAE standard 55.66, New York. ASHRAE (1989), Physiological principles, comfort and health, in Fundamentals Handbook, Atlanta, USA. ASHRAE (1997), Thermal comfort. ASHRAE Handbook of Fundamentals, Chapter 8, Atlanta, USA. Auliciems A (1981), Towards a psychophysiological model of thermal perception, International Journal of Biometerology, 25, 109–122. Bedford T (1936), The warmth factor in comfort at work: a physiological study of heating and ventilation, Industrial Health Research Board Report No. 76, London, HMSO. de Dear R J (1998), A global database of thermal comfort field experiments, ASHRAE Transactions, 104, Part 1. de Dear R J and Brager G S (1998), Developing an adaptive model of thermal comfort and preference, ASHRAE Transactions, Atlanta, USA. de Dear R J and Brager G S (2002), Thermal comfort in naturally ventilated buildings: revisions to ASHRAE Standard 55, Energy and Buildings, 34(6), 549–572. Drury C G (1990), Methods for direct observation of performance, in J R Wilson and E N Corlett (eds), Evaluation of Human Work – A Practical Ergonomics Methodology, London, Taylor & Francis, 35–57. Fanger P O (1970), Thermal Comfort, Copenhagen, Danish Technical Press. Fanger P O, Melikov A K, Hanzawa H and Ring J (1989), Turbulence and draught, ASHRAE Journal, April. Guildford J P (1954), Psychometric Methods, 2nd edn, New York, McGraw-Hill. Hollies N R S, Custer A G, Morin C J and Howard M E (1979), A human perception analysis approach to clothing comfort, Textile Research Journal, 49, 557–564. Houghton F C and Yagloglou C P (1923), Determining equal comfort lines, Journal of ASHVE, 29, 165–176. Humphreys M A (1972), Clothing and thermal comfort of secondary school children in summertime, CIB Commission W45 symposium thermal comfort and moderate heat stress, Watford, London, HMSO. Humphreys M A (1978), Outdoor temperatures and comfort indoors, Building Research and Practice, 6(2) 92–105. Humphreys M A and Nicol J F (1970), An investigation into the thermal comfort of office workers, Journal of the Institution of Heating and Ventilation Engineers, 30, 181–189. ISO 7726 (1985), Thermal Environments – Instruments and methods for measuring physical quantities, Geneva, International Standards Organization. © Woodhead Publishing Limited, 2010
Thermal comfort in buildings
147
ISO 7730 (2005), Moderate Thermal Environments – Determination of the PMV and PPD indices and specification of the conditions for thermal comfort, Geneva, International Standards Organization. ISO 8996 (1990), Ergonomics of the Thermal Environment: Estimation of metabolic heat production, Geneva, International Standards Organization. ISO 9920 (1992), Estimation of the thermal characteristics of a clothing ensemble, Geneva, International Standards Organization. ISO 10551 (1995) Assessment of the influence of the thermal environment using subjective judgement scales, Geneva, International Standards Organization. ISO DIS 28802 (2009) Ergonomics of the Physical Environment – The assessment of environments by means of an environmental survey involving physical measurements of the environment and subjective responses of people, Geneva, International Standards Organization. McIntyre D A (1980), Indoor Climate, London, Applied Science. McNall P E, Ryan P W, Rohles F W, Nevins R G and Springer W E (1968), Metabolic rates at four activity levels and their relationship to thermal comfort, ASHRAE Transactions, 74, Pt I. IV.3.1. Moser C and Kalton G (1971), Survey Methods in Social Investigation, 2nd edn, London, Heinemann. Nevins R G, Rohles F H, Springer W E and Feyerherm A M (1966), A temperature humidity chart for thermal comfort of seated persons, ASHRAE Transactions, 72(I), 283–291. Olesen B W (1985), Local thermal discomfort, in Bruel and Kjaer, Technical Review No. 1, Copenhagen. Olesen B W, Sliwinska E, Madsen T L and Fanger P O (1982), Effects of body posture and activity on the thermal insulation of clothing: measurements by a movable thermal manikin, ASHRAE Transactions, 88(2), 791–805. Parsons K C (1993), Safe surface temperatures, in E J Lovesey (ed.), Contemporary Ergonomics, London, Taylor & Francis. Parsons K C (2002), The effects of gender, acclimation state, the opportunity to adjust clothing and physical disability on requirements for thermal comfort, Energy and Buildings, 34, 593–599. Parsons K (2003), Human Thermal Environments, 2nd edn, London, Taylor & Francis. Rohles F H (1970), Thermal sensations of sedentary man in moderate temperature, Institute for Environmental Research: Special Report, Kansas State University, USA. Rohles F H and Nevins R G (1971), The nature of thermal comfort for sedentary man, ASHRAE Transactions, 77(1), 239–246. Sinclair M A (1990), Subjective assessment, in J R Wilson and E N Corlett (eds), Evaluation of Human Work – a practical ergonomics methodology, London, Taylor & Francis, pp. 58–88. Weston J C (1951), Heating research in occupied houses, Journal of the Institute of Heating and Ventilating Engineers, 19, 47–108. Wyon D P and Halmberg I (1972), Systematic observation of classroom behaviour during moderate heat stress, in Thermal Comfort and Moderate Heat Stress, Proceedings of CIB, W45 Symposium, Watford, London, HMSO.
© Woodhead Publishing Limited, 2010
6
Environmental health and safety in buildings
P. B r i m b l e c o m b e, University of East Anglia, UK
Abstract: A surprising range of environmental hazards are present in commercial and residential interiors. These range from issues of fire safety and the problems of combustible materials through to the hazards created by indoor air pollution. Decreased ventilation and the widening variety of indoor materials have enhanced the number of compounds to which we are exposed to indoors. Sick building syndrome and respiratory illnesses have been attributed to these exposures, so the management of occupied spaces has been an increased focus of regulation. Key words: fire, indoor air pollution, sick building syndrome, outgassing.
6.1
Introduction
The question of dangers in occupied spaces can seem somewhat surprising, especially when they refer to our homes which are familiar environments. Typically these are spaces we retire to to escape the noise and bustle of the outside world. They are environments where we usually feel in control, yet these have a range of problems in the modern world, that has made them an increasing area of study and even regulatory concern. The very notion of regulation raises issues of personal freedom and the problem is often blurred as it can be unclear which government agency is appropriate for indoor spaces. Indoor air, for example, is often not treated by the same government agency as outdoor air, thus departments of the environment are frequently replaced by departments of health, housing, safety or industry. The heterogeneous nature of the indoor environment has added to the difficulties of monitoring and regulating these volumes. Some issues have been rather mechanical and easy to approach, such as the flammability of indoor materials, where regulation is widespread, while others such as sick building syndrome, where the sociological context becomes an important factor, remain problematic. Hazards in the residential environment have frequently been linked with adverse health outcomes, especially among children (Klitzman et al. 2005). These include: the problems of lead-based paint hazards that can be associated with elevated blood lead levels, illnesses that arise from dampness and fungi and the microbial volatile organic compounds (MVOCs), dust mite allergens 148 © Woodhead Publishing Limited, 2010
Environmental health and safety in buildings
149
with asthma and allergy and a range of risks associated with electrical hazards, fire hazards and emissions of materials that are flammable. Infants spend much time inside so there are issues here (Franklin 2007), and elderly or infirm people are also exposed to similar hazards. There have been increasing pressures from buildings regulations to set standards for the design and construction of buildings to ensure the safety and health of people in or about those buildings. In the UK the Building Regulations are made under powers provided in the Building Act 1984, and apply in England and Wales (http://www.planningportal.gov.uk/england/ genpub/en/1115313929034.html). These reflect concern over sustainability and climate change, but the Regulations also ensure that fuel and power are conserved. Schedule I to the Building Regulations contains a number of sections relevant to the concerns of this chapter, most notably Part D Toxic substances and Part F Ventilation, although the Schedule acknowledges that some buildings will require greater sensitivity and more flexibility. These include historic buildings, so English Heritage have produced, for example, an Interim Guidance Note on how to balance the needs for energy conservation with those of building conservation. International regulation is also in evidence with the World Health Organisation (WHO) starting to show an interest in the indoor environment that parallels its work on outdoor air quality. The WHO list of pollutants recommended for guideline development (group 1) and those with insufficient scientific evidence and corresponding systematic reviews (group 2) are as follows: ∑
Group 1 pollutants: 1.1 formaldehyde, 1.2 benzene, 1.3 naphthalene, 1.4 nitrogen dioxide (NO2), 1.5 carbon monoxide (CO), 1.6 radon, 1.7 particulate matter (PM2.5 and PM10), 1.8 halogenated compounds (tetrachloroethylene, tricholoethylene, etc.), 1.9 polycyclic aromatic hydrocarbons (PAH), especially benzo-a-pyrene (BaP). ∑ Group 2 pollutants – current evidence uncertain or insufficient for guidelines: 2.1 toluene, 2.2 styrene, 2.3 xylenes, 2.4 acetaldehyde, 2.5 hexane, 2.6 nitric oxide (NO), 2.7 ozone (O3), 2.8 phthalates, 2.9 biocides, pesticides, 2.10 flame retardants, 2.11 glycol ethers, 2.12 asbestos, 2.13 carbon dioxide (CO2), 2.14 limonene, pinene, 2.15 total volatile organic compounds (TVOC). In this context we can see a focus on a widening range of organic compounds driven especially through concerns over ‘tight buildings’ or ‘sick building syndrome’. Many of the larger organic molecules are not familiar from an engineering perspective, although useful textbooks in this area include Indoor Air Pollution edited by Peter Pluschke (2004), which treats the organic chemicals within the context of indoor air and for reference the classic data source on environmental organic compounds is Karel Verschueren’s Handbook of Environmental Data on Organic Chemicals (1996). A good
© Woodhead Publishing Limited, 2010
150
Materials for energy efficiency and thermal comfort in buildings
listing of the compounds found in residential and commercial buildings is found in the 2003 Lawrence Berkeley National Laboratory report: Volatile Organic Compounds in Indoor Air: A Review of Concentrations Measured in North America Since 1990 (http://eetd.lbl.gov/ied/pdf/LBNL-51715.pdf) by Hodgson and Levin. The health effects of these compounds are not easy to interpret at the low concentrations found, but typically some such as aldehydes are irritants, others have odour and some are potential carcinogens. The difficulties are that the health outcomes at low concentration may arise from reactions or synergistic effects. Our increasing worries about risk in pubic spaces received attention in the Commission for Architecture and the Built Environment report Living with risk – Promoting better public space design (CABE 2007), which recognised the need to carefully balance the risks in their design. The authors of the report envisaged that public spaces are in danger of becoming bland and standardised because of over-sensitivity to risk, arising from misplaced fears of a rampant compensation culture and unquestioning interpretations of health and safety aspects of indoor building regulations. A range of issues have emerged in recent years in terms of public spaces. The public has been worried about the issue of carpets and allergens, and exposure to indoor dust and fungi from damp. This has broadened to strive to minimize the negative effects to individuals from exposure to perfumes, scents and other odours within our facilities. Perhaps of widest impact has been the increasing number of countries that have developed smoke-free legislation for public places to limit exposure to the dangers of second-hand tobacco smoke.
6.2
Safety issues in occupied spaces
There are a wide range of safety issues indoors that include escape, security and falls, but this chapter will focus on fire and what might be regarded as threats to the indoor environment. There has been a rising interest in indoor air pollution in recent years, with countries such as South Korea promulgating legislation and the WHO addressing the potential in its report from October 2006 Development of WHO Guidelines for Indoor Air Quality (WHO 2006) for regulation of pollutants that affect health. There has also been increased litigation over issues such as exposure to indoor mould and much concern from the occupants of new buildings about sick building syndrome and multiple chemical sensitivity, although both these have been resistant to clear understanding or ready solutions. There is currently a view that we spend a great deal of time indoors and that this is increasing. From 1992 through 1994, the US Environmental Protection Agency used telephone interviews of participants who kept diaries to record their activities and locations. This probability-based National Human Activity
© Woodhead Publishing Limited, 2010
Environmental health and safety in buildings
151
Pattern Survey (NHAPS) was conducted with over 9000 respondents across the country (Brasche and Bischof 2005). The national results were generally consistent with an earlier Californian study, with the mean percentage of time spent indoors being 87%. This was split into 69% of time spent in a residence and 18% of the time spent in other indoor locations. Studies in Germany (Brasche and Bischof 2005) give very similar results: the overall mean time spent at home was 15.7 (65%) hours per day, consistent with the earlier German Environmental Survey (1990/92) and a small German study in 1987. Thus there is evidence of the large amount of time we spend indoors, but less convincing is that this is increasing dramatically; indoor activities may have changed along with the range of consumer products. Additionally problems could have increased indoors because of pressures to decrease ventilation as part of energy conservation. This arises because of the desire to provide adequate ventilation at minimum energy cost (Sherman 1999). Typical ventilation rates from an engineering perspective are given in Table 6.1. There has also been an increased spread of heating and ventilation systems which have the potential to negatively affect indoor air quality, such as the outbreaks of Legionella (Diederen 2008) that have been particularly widely reported. Air quality in schools has become a special problem that can often be increased through parental worry over the health of their children. Air pollution in schools has been studied frequently in recent years (e.g. Janssen et al. 2001), given the potential vulnerability of younger children to the effects of indoor air pollutants and disease. Indoor air pollution might also reduce the productivity of teachers and degrade the student learning experience (e.g. Yang et al. 2009). Modern industries, such as electronics and nanotechnology, have emphasised the importance of clean production facilities where it has become important to keep particles and pollutants from sensitive nano-fabricated materials (Clark et al. 1992, Muller et al. 1994, Lebens et al. 1996, Bhushan and Chandra 1999). Telephone switching centres have proved vulnerable to air pollutants (e.g. Shields and Weschler 1992) and photographic and optical manufacturing (Spyak and Wolfe 1992) must maintain high standards. Museums, historic properties, art galleries and major libraries focused on the traditional agents of deterioration: relative humidity, temperature and light in the past. These buildings have experienced air pollution (Brimblecombe 1990, 2008) and, more recently, dust (Lloyd et al. 2007) has been shown to be an important consideration in the management of their interiors.
6.3
Combustion, fire and combustible materials
Combustion indoors can be intentional, as in terms of heating or cooling or during fires, where very special risks are imposed on occupants and
© Woodhead Publishing Limited, 2010
152
Materials for energy efficiency and thermal comfort in buildings Table 6.1 Air change rates recommended for some typical rooms and buildings (http://www.engineeringtoolbox.com/air-change-rate-roomd_867.html) Building/room
Air change rates (AC/h)
All spaces in general Attic spaces for cooling Auditoriums Banks Barber shops Bars Beauty shops Boiler rooms Cafeterias Churches Computer rooms Court houses Department stores Dress shops Engine rooms Factory buildings, ordinary Foundries Garages repair Garages storage Homes, night cooling Kitchens Laundries Libraries, public Medical centres Municipal buildings Museums Offices, public Offices, private Post offices Restaurants Shopping centres Supermarkets Town halls Theatres Warehouses Waiting rooms, public
min 4 12 – 15 8 – 15 4 – 10 6 – 10 20 – 30 6 – 10 15 – 20 12 – 15 8 – 15 15 – 20 4 – 10 6 – 10 6 – 10 4 – 6 2 – 4 15 – 20 20 – 30 4 – 6 10 – 18 15 – 60 10 – 15 4 8 – 12 4 – 10 12 – 15 3 4 4 – 10 8 – 12 6 – 10 4 – 10 4 – 10 8 – 15 2 4
the fire services from exposure to combustion products, during firefighting. There is a long history of exposure to indoor smoke. Seneca, Emperor Nero’s tutor, complained bitterly about exposure to the smoke of green wood from indoors fireplaces. In medieval England charcoal was often used for heating as few of the houses had chimneys. Exposure to wood smoke indoors remains a considerable problem in much of the world and
© Woodhead Publishing Limited, 2010
Environmental health and safety in buildings
153
has been the impetus for many studies that have health perspectives (Smith et al. 2000), along with pressures for simple, inexpensive but low emission cook-stoves. There are frequently poverty and gender issues here. It is women in the developing world that seem to be exposed at the highest concentrations and poor people who have less choice over the fuels they use so are disproportionately exposed to high indoor air pollution (Adonis and Gil 2001, Kavi Kumar and Viswanathan 2007). Space heating, especially the use of kerosene heaters, which was common in the past, can lead to high concentrations of air pollutants indoors (Leaderer 1982). Carbon monoxide is a particularly critical indoor pollutant, and in many countries it accounts for more than half of the accidental poisonings (Raub et al. 2008) This can be especially severe as ventilation may be deliberately limited in winter to conserve heat, so carbon monoxide from poorly vented heaters can reach high concentrations, or gas lines may leak unnoticed into rooms. These problems can disproportionately affect the poor or the elderly, even in more salubrious neighbourhoods (Brimblecombe et al. 1996). Carbon monoxide poisoning can reach epidemic proportions in severe winter storms where electrical failures can cause residents to use unconventional methods of heating or attempt to generate their own electricity. Again there are significant social issues with high frequency of problems among ethnic minority groups with poor reading ability in the language used for warning labels (Houck and Hampson 1997). Kerosene is used for cooking in some countries. In Indian households there were noticeable increases not only in indoor particulate materials, but also VOCs and PAH with naphthtalene, benzo(a)pyrene and phenanthrene all having I/O greater than 7 (Pandit et al. 2001). There have also been a series of investigations suggesting that gas cooking had the potential to increase indoor exposure to NO2. In kitchens these were associated, classically by Melia and his co-workers, with an increased risk of respiratory illnesses, especially among children (Melia et al. 1985). The problem can be improved by increasing the ventilation in kitchens, particularly the installation of hoods over stoves. Fire statistics from the United Kingdom suggest that the majority of deaths in fires result from inhalation of toxic gases that are produced in the fires. Carbon monoxide once more is the most severe hazard, although the products of thermal decomposition or combustion of combustible material produces toxic gases. These vary according to the material burnt but cover a wide range, and toxic products are also dependent on the fire conditions. The gases can be asphyxiants which cause hypoxia. Others are respiratory irritants that stimulate nerve receptors in the eyes, nose, throat and upper respiratory tract. At sufficiently high concentrations, most irritants can also penetrate deeper into the lungs, causing pulmonary irritation effects which are normally related both to concentration and to the duration of exposure.
© Woodhead Publishing Limited, 2010
154
Materials for energy efficiency and thermal comfort in buildings
After exposure respiratory distress and even death can occur from a few hours up to several days after exposure due to asphyxiation from pulmonary oedema (Hartzell 2001). multiple gas exposures can be considered in terms of a fractional effective dose (FeD), which can be calculated by summing the concentrations of the fire effluents and dividing by the lethal concentrations: FeD =
m [co] 21 – [o o2 ] [Hc cN N] [Hcl] [HcHo] [Ac] + + + + + [co o 2 ]]-b 21 – LC50,O2 LC50,CN LC50,HCl LC50,HCHO LC HC HCHO 50,Ac
where the lethal concentration for 50% of the population (LC50) over a 30 min exposure time, Ac is acrolein. The first term, the effect of the CO, is enhanced by the increase in respiration rate caused by high concentrations of co2 (expressed as a step function with one set of values of constants m and b for co2 concentrations below 5% and another for those above 5% (Hull et al. 2008)). Table 6.2 presents potential exposure limits to toxic gases released during fires. Table 6.2 Potential limits to exposure from toxic gases released during fires (data adapted from Hartzell 2001 and http://www.doctorfire.com/toxicity.html) Safea ppm
Formula
Gas
CO2 C 2H 4O C 2H 4O 2 NH3 HCl CO HBr NO COS H 2S HF C 3H 4N COF2 NO2 C 3H 5O CH2O SO2 HCN C 9H 6O 2N 2 COCl2 C 4F 8
carbon dioxide acetaldehyde acetic acid ammonia hydrogen chloride carbon monoxide hydrogen bromide nitric oxide carbonyl sulfide hydrogen sulfide hydrogen fluoride acrylonitrile carbonyl fluoride nitrogen dioxide acrolein formaldehyde sulfur dioxide hydrogen cyanide toluene diisocyanate phosgene perfluoroisobutylene
100 3500b 100
Unsafea ppm
1000 35000b 1000
50
500
25 3 25 15
250 30 250 150
a
Assumed LC50 30 min >150,000 20,000 11,000 9000 3700 3000 3000 2500 2000 2000 2000 2000 750 500 300 250 – 135 100 90 6
Concept of limits on exposure of occupants as being safe or unsafe for most occupants. b Units: ppm min.
© Woodhead Publishing Limited, 2010
Environmental health and safety in buildings
155
Plastic is often a significant hazard in fire; for example, as much as 0.3 g Hcl can be produced from 1 g of polyvinylchloride (PVc) during poorly ventilated fires (Hull et al. 2008). Polyurethanes are widely used in paints and yield a wide range of combustion products, including alkenyl isocyanates, propylene through to octylene derivatives during combustion (Boutin et al. 2004). in a recent eU project, ToXFire, that aimed to set guidelines for management of fires in chemical warehouses, test fires (Andersson et al. 2005) included three compounds with S, N, c and polymers: (1) tetramethylthiuram monosulphide (TmTm) used in vulcanising processes, (2) 4-chloro-3-nitrobenzoic acid (cNBA) used in dye production, (3) chlorobenzene and polymers, (4) nylon 6,6 (nylon, also containing N) and (5) polypropylene. Hydrogen chloride and sulphur dioxide yields are high compared with the maximum theoretical yields, which is in agreement with the assumption that these compounds are end products in the case of well-ventilated fires. Hydrogen cyanide (HcN) was formed in the experiments with nylon, TmTm and cNBA. But the yields are rather low, with a maximum yield of around 2%.
6.4
Infiltration of outdoor pollutants
Air pollutants found indoors can accompany incoming air or arise from processes within buildings. The same pollutant can have both indoor and outdoor sources. Advection of pollutants through windows or doors or through active ventilation via air conditioning systems is a most obvious source of indoor pollutants. Sensitive industrial facilities or archives carefully control the quality of incoming air, filtering and sometimes scrubbing the air free of pollutant gases. once indoors many pollutants react with the indoor surfaces and this reduces their concentration. This is part of the explanation for the advice given to sensitive individuals that they should remain indoors during air pollution episodes. The reduction in pollutant concentration can be represented as an indoor–outdoor ratio of pollutant gases. This has become an important concept in the understanding and management of indoor spaces, and can be described in terms of the simple equation: Ci/Co = E/(E + vd A/V) where: C i = indoor pollutant concentration, C o = outdoor pollutant concentration, E = air exchange rate of the room (hr–1), A = surface area of interior (m 2 ), V = volume (m 3 ) of interior, ratio, and vd = average deposition velocity (m hr–1 or converted from cm s–1). The air exchange rate has already been discussed in terms of the ventilation of typical spaces (see Table 6.1). The key notions are deposition velocity and air exchange rate in determining indoor–outdoor ratios. The deposition velocity represents the way in which a gas deposits and then sticks irreversibly
© Woodhead Publishing Limited, 2010
156
Materials for energy efficiency and thermal comfort in buildings
to a surface. It can be thought of in terms of a number of separate resistances such that:
vd = [ra + rb + rs]–1
where ra, rb and rs are the aerodynamic resistance, the boundary layer resistance and the surface transfer resistance, respectively. The resistance at the surface can be thought of in terms of surface reactivity. Deposition velocity has been represented in terms of the uptake coefficient or sticking coefficient by Cano-Ruiz et al. (1992), where this is the ratio, in a molecular sense, of the fraction of all pollutant molecules colliding with the surfaces that result in irreversible removal. The magnitude of the deposition velocity can increase very dramatically with humidity or even the hygroscopicity of the surface. Typical values are given in Table 6.3 and more extensive tabulations onto indoor materials appear in Grontoft and Raychaudhuri (2004). The ventilation system itself can be a source of indoor pollutants. These are derived from compounds found deposited on the filters and within the ducting, but odour can also arise from heating coils and heat exchangers. These odours arise from volatile components within the dust. They are emitted more effectively when temperature and relative humidity increase. It is the longer chain aldehydes which contribute most to the odour, with nonanal and decanal especially important. Longer chain carboxylic acids have low odour thresholds, but they are bound to the dust more effectively. However, unsaturated nonenal, which has an unusually low odour threshold, might also be an important contributor to odour. Nitrogen containing compounds, such as indoles (e.g., 1H-isoindole-1,3(2H)-dione), pyrroles, quinolines, and pyridines (methyl and dimethylpyridine), could also be released through thermo-desorption (Hyttinen et al. 2007). Additionally n-aldehydes can also Table 6.3 Deposition velocities of gases to typical indoor materials at 70% RH (for full details see Grontoft and Raychaudhuri 2004)
O 3 (cm/s)
NO2 (cm/s)
SO2 (cm/s)
Glass Dense alkaline stone Soft alkaline stone Fine concrete Brick Painted wood and surfaces Treated gypsum board Metal Wool Wallpaper Cloth >1 year old Plaster
0.0002 0.0002 0.068 0.019 0.135 0.01 0.063 0.0024 0.1 0.08 0.0088 0.044
0 0 0.025 0.01 0.076 0.0043 0.0043 0.0014 0.12 0.017 0.025 0.03
0 0.014 0.15 0.2 0.016 0.047 0.16 0.011 0.059 0.043 0.023 0.17
© Woodhead Publishing Limited, 2010
Environmental health and safety in buildings
157
be produced via reaction with ozone with surfaces (see Wang and Morrison 2006).
6.5
Indoor emissions and outgassing
Construction materials and furnishings outgas volatile compounds over time as they age or degrade. This adds to outdoor pollutants or those produced from combustion processes indoors during cooking and heating. This section will take a brief look at some of the principal components of occupied spaces that are likely to release gases to the indoor environment, but more comprehensive lists of sources (Wang et al. 2007) and greater details of the chemistry are available elsewhere (Uhde and Salthammer 2007).
6.5.1 Wood As wood ages it releases a range of materials, most notably acids and also aldehydes which derive from heat-treated woods. Formic and acetic acid are best known, but some longer chain carboxylic acids are also products from wood. Substantial emissions of acetic acid and/or furfural can also be observed for heat-treated wood (thermowood) or kiln-dried samples of various wood species (e.g. beech, rubber wood, etc.) (Uhde and Salthammer 2007). Terpenes such as a-pinene and 3-carene are commonly released from air-dried wood (Manninen et al. 2002) and can be an important source of these larger semi-volatile organic compounds indoors (Hodgson et al. 2002). Chloromethane can be found as fungi (Hymenochaetaceae) rot wood and additionally pectin reacts with chloride ion to form chloromethane (Watling and Harper 1998).
6.5.2 Floors Floors may be wooden, but also incorporate glues and varnishes, etc. Parquet floors of birch, coated with acrylic lacquer and adhesive emit n-butylacrylate and n-butanol from the hydrolysis of n-butylacrylate ester along with pentanal and hexanal from the degradation of fatty acids (Uhde and Salthammer 2007). Horn (1998) has reported high emissions of furfural and acetic acid from composite cork products and Udhe and Salthammer (2007) list carbonyl disulfide, acetic acid, furfural styrene, benzaldehyde, cyclohexanone, phenol methylbenzoate, 4-phenylcyclohexene and benzophenone from the degradation of hemicellulose, adhesives binders and photo-initiators from a new cork parquet floor. Linoleum (Jensen et al. 1995a, Jensen et al. 1995b) can be a source of volatile organic compounds as the oxidation of linolenic acid leads to unsaturated compounds like 2,4-heptadienal (Belitz and Grosch 1992).
© Woodhead Publishing Limited, 2010
158
Materials for energy efficiency and thermal comfort in buildings
6.5.3 Paint, solvents and preservatives Paints and varnishes are an important source of aromatic compounds (Edwards et al. 2001). Traditional paints, based on boiled linseed oil and other natural materials have become popular in recent years because the paint is said to last significantly longer than ordinary gloss paints primarily as the vegetable resins are impervious. Additionally there is a well advertised belief that these paints have no chemical emissions. However, hexanal, nonanal and propanal are released, while Toftum et al. (2008) have shown that beech boards painted with an ‘eco’ paint emitted large amounts of the terpene limonene and lesser amounts of carvone. Furniture coatings containing alkyd or natural resins (Afshari et al. 2003, Salthammer 1995a, Salthammer 1995b) on oxidation form many types of volatile aldehydes. Typical degradation products of oleic acid are saturated aldehydes from heptanal to decanal, while linoleic acid gives mainly hexanal. Organic solvents were used in paints more extensively in the past so compounds such as toluene, isopropanol, acetone and butyl acetate were emitted, but increasingly water-based paints have been adopted. The desire to reduce the volatile compounds emitted from paints and lacquers has encouraged manufacturers to use more UV-curable formulations. These require a photo-initiator. Uhde and Salthammer (2007) investigated the importance of the photo-initiator (a blend 1-hydroxy-cyclohexyl-phenone (HCPK)/benzophenone) and its degradation products as a pollutant source to indoor air. Cyclohexanone was formed from the hydroxy–cyclohexyl radical upon cleavage of HCPK. The photo-initiator benzophenone was found along with its degradation products benzaldehyde and methyl benzoate. Some indoor materials are protected with pesticides. Naphthalene concentrations can be high indoors, particularly in warmer climates where it is frequently used as an insecticide. Pesticides can be deliberately sprayed into air by householders or evaporate from treated products. Given our sensitivity to pesticides, risks from these need to be reduced and often require more thought in our approach to cleaning (see Section 6.6.2). Some pesticides degrade within materials over time. An important example of this is the production of indoor pollutants from pentachlorophenol, commonly used to protect wood from fungi, as the compound degrades over time and gives rise to emissions of chloroanisoles (Gunschera et al. 2004).
6.5.4 Fabrics and coverings Indoors large areas of fabrics cover the floors and furnishings in addition to acting as curtains. The tendency in many countries for increased areas of floor to be covered by carpets raised concern in the late 20th century because of an increasing frequency of asthma and its potential link to dust mites that
© Woodhead Publishing Limited, 2010
Environmental health and safety in buildings
159
inhabit carpet. Homeowners were sometimes advised to remove carpet from their rooms to limit the risk to allergy and asthma patients. There has been much disagreement about this because clean, dry, well-maintained carpets can also improve air quality as they can absorb both inorganic pollutants such as ozone and SO2 and organic compounds (Won et al. 2001). Additionally, emissions from other types of flooring could impose other types of risk. Volatile organic substances released from carpets are highly variable and depend on their type. Often these are not related to the carpet surface itself, but to the foam backing. Quite exotic substances can be formed during the reaction, which is a radical-induced polymerisation that creates the styrene–butadiene copolymers (SBR) in foam. Residual monomers styrene and butadiene are removed by distillation, but odour-intensive compounds 4-phenylcyclohexene (4-PCH) can remain (Uhde and Salthammer 2007). PVC-backed carpet emitted formaldehyde, vinyl acetate, isooctane, 1,2propanediol and 2-ethyl-1-hexanol with vinyl acetate and propanediol at the highest emission rates, while a polyurethane-backed carpet emitted mostly butylated hydroxytoluene (Hodgson et al. 1993). Some materials with a high sulphur content such as wool can give off large amounts of carbonyl and hydrogen sulphide (Brimblecombe et al. 1992). Other more exotic coverings can be important in some environments. Chang et al. (1995) studied volatile organic compounds (VOCs) released from athletic running tracks which included: 2-methyl furan, butanal, methyl ethyl ketone, benzene, heptane, methyl isobutyl ketone, toluene, octane, hexanal, nonane+ethylbenzene, xylenes+styrene, propyl benzene, decane, 1,3,5-trimethyl benzene, 1,2,4-trimethyl benzene, 1,2,3-trimethyl benzene and undecane. Hexanal was the most common and the principal compound from the synthetic rubber and polyurethane tracks studied.
6.5.5 Flame retardants Flame retardants are used to make materials, especially plastics, wood and wood-based textiles flame-proof. Worldwide in 2000, usage of flame retardants was in excess of 1.08 million tons of which nearly a quarter were organophosphate flame retardants. These also include a range of phthalates (possible endocrine disruptors) and pose potential risk as they outgas and become additionally incorporated into indoor dust. Added to this, retardants can release volatile products derived from rather non-volatile precursors that yield 1-chloro-2-propanol, 2-chloro-1-propanol and 1,3-dichloro-2-propanol. These can be found in indoor air samples following hydrolysis of flame retardants such as tri(chloropropyl) phosphate and tris(dichloropropyl)phosphate, respectively (Salthammer et al. 2003). The latter requires increased attention since 1,3-dichloro-2-propanol has been acknowledged as a carcinogenic substance.
© Woodhead Publishing Limited, 2010
160
Materials for energy efficiency and thermal comfort in buildings
A study by Ni et al. (2007) of wallpapers showed a significant positive correlation between emissions of tris(2-chloroisopropyl)phosphate (TCPP) and its content in wallpaper samples. Additionally a linear relationship (Arrhenius like) was found between reciprocal temperature and the logarithm rate of the TCPP emission rate at different temperatures. The observed maximum emissions of TCPP from 5 w/w% content wallpaper materials was 645 mg m–2 h–1, at 25 oC. Nevertheless, the inhalation of phthalates and particulate organic chlorine at levels reaching the allowable daily intake seems unlikely under normal living conditions. However, the evaluation of the exposure to household dust is far more difficult if we include ingestion (Wensing et al. 2003).
6.5.6 Plastics, foams and glues Glue is an especially important source of indoor air pollutants, notably formaldehyde. It has a wide range of sources in air and is a frequent oxidation product outdoors. Formaldehyde is characteristic of hospitals where releases to air will occur when it is used for sterilisation. More general indoor sources are from formaldehyde-based insulation and furniture foams, cigarette smoke and carpets, resins, wood, paints and glue, which mean indoor concentrations can be very high (see Table 6.4). It has long been known that the hydrolysis of ureids (glue based on urea-formaldehyde), due to the unavoidable presence of water, leads to hydrolysis of the N–O bond and, as a consequence, to the release of formaldehyde (Uhde and Salthammer 2007). Fibreboards can be especially problematic because of the urea-formaldehyde resins used to bond the constituent parts together. Other aldehydes and organic acids arise from woods, insulating foams, textiles and glues. Sensory irritation of some Table 6.4 Some reported occupational and environmental concentrations of formaldehyde (http://www.mflohc.mb.ca/fact_sheets_folder/formaldehyde.html) Site
Concentration (ppm)
Outdoors Rural pastures Los Angeles Basin Outdoor air in industrial cities Smog
0.0005–0.002 0.01–0.048 0.004–0.015 0.09–0.15
Indoor Conventional homes Homes with urea formaldehyde foam insulation Mobile homes Schools Offices Clothing stores Passive cigarette smoke
0.02–0.095 0.02–0.11 0.1–0.5 0.13–0.57 0.02–0.12 0.9–3.3 0.23–0.4
© Woodhead Publishing Limited, 2010
Environmental health and safety in buildings
161
shorter aldehydes (e.g., formaldehyde and acrolein) might be higher than that of the longer ones (in passing, Hyttinen et al. 2007). Because of the importance of furniture in enhancing the exposure to formaldehyde in the home, there has been increasing regulation of formaldehyde in furnishings. The UK Department for Environment, Food and Rural Affairs (DEFRA) introduced Building Regulations to prohibit the use of urea-formaldehyde foam (UFF) in buildings and to control its installation elsewhere. Broadly the regulations only permit UFF insulation between cavity walls with masonry inner and outer leaves. Here the inner leaf should afford good resistance to vapour penetration. Plastics often contain plasticisers to improve the plasticity of the product. Those present in phthalates and adipate containing plastics tend to hydrolyse over time. A typical reaction product found in indoor air samples is 2-ethyl1-hexanol from the hydrolysis of diethylhexylphthalate or butanol from the hydrolysis of butylphthalates or n-butylacrylate. Both substances have a strong odour and can lower the perceived air quality.
6.5.7 Secondary production There are also contributions to indoor air from the reaction of pollutant gases with surfaces. Such secondary emissions arise when ozone reacts with paints to give formaldehyde (Reiss et al. 1995) and on carpets (Weschler et al. 1992) or counter tops and releases a range of aldehydes, especially nonanal (Wang and Morrison 2006). We are all aware of the smell of tobacco smoke that persists long after smoking has ceased. This can be due to the sorption of organic compounds such as nicotine and their slow desorption which may take years (Van Loy et al. 2001). Some of these compounds are organic bases and subtle shifts in the acidity of wall coverings could affect the rate of release.
6.6
Occupant activity
6.6.1 Cooking Obviously kitchens expose occupants to combustion products, and in many countries this exposure may be largest for women and children. Beyond combustion products, the preparation of food can involve the release of ethanol or acetic acid (vinegar). The cooking process produces organic materials such as n-alkanes (C25–C36), saturated and unsaturated monocarboxylic acids (C16–C24), saturated and unsaturated dicarboxylic acids (C6–C14), nonanal, lactones, levoglucosan, along with aromatic compounds, particularly toluene and the xylenes (Edwards et al. 2001; Zhao et al. 2007) that can be found as films on
© Woodhead Publishing Limited, 2010
162
Materials for energy efficiency and thermal comfort in buildings
window glass (Liu et al. 2003). Oil droplets are also forced into the air along with particles of ingredients. We are all aware of the irritancy of capsaicin in kitchen air when chilli peppers are being fried. Frying itself with modern Teflon-coated pans releases a range of compounds such as polyfluoro- and/ or polychlorofluoro- (C3–C14) carboxylic acids, a pyrolysis product of polytetrafluoroethylene (Teflon). Although there are few cases of effects on humans, their impact on birds is well known (Boucher et al. 2000).
6.6.2 Cleaning and fragrances Cleaning products and fragrances have an impact on the composition of indoor air. In addition to abrasion, cleaning releases a range of volatile compounds and other particles to indoor air (Wolkoff et al. 1998). These include surfactants (from detergents), complexing agents as water softeners (e.g. EDTA), disinfectants and waxes. Typical volatile compounds found in cleaning agents include alkanes and alkenes and various halogenated derivatives, alcohols, ethers and carboxyl compounds. There have been relatively few studies that assess the risk balance involved in cleaning within buildings. In domestic interiors, fragrances in cleaning products represent an additional source of the terpenes, a-pinene and limonene (Edwards et al. 2001) along with synthetic aromatic nitro-musks and polycyclic musks, scenting agents in cosmetics, perfumes and cleaning products, that are widely dispersed in the environment. These have largely replaced natural musks, but increasing concern about their environmental impact may have led to lower production (Weschler 2009). Terpentine oils are produced in large amounts (~0.3 Mt/a) and limonene is increasingly seen as a safe fragrance, cleaner and solvent and is globally produced in very large amounts (~70kt/a). Little is known of the risks through inhalation exposure to d-limonene, although it is an irritant. However enhanced risks may arise from its oxidation products and indoor air chemistry. Increasing numbers of people express a sensitivity towards perfumes and scents. There is also a growing concern about exposure to the volatile materials from household products such as air fresheners. There was more than a 30% increase in babies that suffered diarrhoea in homes where air fresheners were used every day, compared with homes where they were used once a week, while their mothers had more headaches and depression (Farrow et al. 2003).
6.6.3 Ozone generation Indoor activities are contributors to the generation of ozone gas. It is sometimes argued that ozone can arise from electrical equipment and photocopying
© Woodhead Publishing Limited, 2010
Environmental health and safety in buildings
163
machines, but the amounts are quite small. Ozone is produced in larger amounts from ozone generators designed to remove odours and to destroy organic compounds, though there is increased awareness that these should not be used for occupied spaces. Elevated concentrations of ozone may be used for deodorising hotel rooms or homes affected by fires and to disinfect mould-afflicted buildings. Here ozonation can lead to the formation and emission of carbonyls (Poppendieck et al. 2007).
6.7
Transformations within the interior
Indoor air is chemically active. As with secondary pollutants produced by reactions in outdoor air that are characteristic of the Los Angeles smog, indoor air has its own transformations (Weschler and Shields 1997). The transformations of compounds in indoor air can be a function of light. In particular, this occurs as the result of the decrease in the amount of light as air moves indoors. This occurs in large rooms with weakly absorbing walls (metal, polymer or glass). NO2 can be generated as the ‘equilibrium’ shifts to the right (Brimblecombe et al. 1999):
NO + O3 ´ NO2 + O2 + hu
In buildings with a high surface to volume ratio (i.e. small rooms), surface absorption can result in the ozone and to a lesser extent nitrogen oxides being absorbed by walls. However, surface chemistry can transform NO2, so the situation may be different:
2NO2(ads) + H2O Æ HONO + HNO3
There is also an active organic chemistry within interior spaces. Oxidation reactions in indoor air have been studied because of the potential that the oxidation products of volatile organic matter may be more harmful to health than the precursors. Oxidation products include free radicals, secondary ozonides, epoxides, aldehydes, ketones, acids, diacids and dicarbonyls (Weschler 2009). Ozone reactions with the terpenes typically found in rooms produce particles. Such chemical transformations of limonene and a-pinene reactions may be responsible for much of the formaldehyde, almost all of the p-tolualdehyde and a substantial fraction of the particle mass generated indoors (Weschler and Shields 1999, Fan et al. 2003). This can be an important source as they are components of air fresheners and ozone is advected through open widows or more critically arises where ozone generators are used. The particles produced in these reactions are in the submicron range and thus a potential health risk as they reach deep into the lung.
© Woodhead Publishing Limited, 2010
164
6.8
Materials for energy efficiency and thermal comfort in buildings
Particles in buildings that impact on environmental health and safety
A wide variety of particles are found indoors and these range from the large particles that trouble households as dust, often containing fibres as much as a millimetre in length through to much smaller particles. Soot arises from incomplete combustion and is common indoors, normally being associated with wax candles, incense, mosquito coils, gas stoves or smoking, and many of the particles are in the submicron range (Afshari et al. 2005).
6.8.1 Non-viable particles Concrete is known to yield small alkaline particles (Toishi and Kenjo 1967, 1975) and plaster indoors is likely to give fine gypsum as it degrades (Camuffo et al. 1999). Mechanical abrasion and cleaning is a source, especially vacuum cleaners which produce fine particles. The degradation of materials containing asbestos has been a special problem. Asbestos was widely used in the building industry because of their resistance in fires. Asbestos minerals are highly fibrous and exposure can lead to tumours of the respiratory system and lung cancer, so asbestos is well regulated and within the UK. the three previous sets of regulations covering the prohibition of asbestos, the control of asbestos at work and asbestos licensing now fall within the Control of Asbestos Regulations 2006. It is important to distinguish between ‘friable’ and ‘non-friable’ asbestos, because it is the friable material that produces dangerous fibres. Friable materials are those that contain more than 1% asbestos and can be reduced to powder by the human hand.
6.8.2 Spores and bacteria In addition to non-viable particles there are also numerous fungal spores, bacteria and fragments of biological material. The production of these has become particularly associated with dampness in buildings which encourages the growth of fungi. Although the future climate of Britain may be drier, warmer conditions could enhance fungal growth. Fungal infections are often associated with microbial volatile organic compounds (MVOCs) which include alcohols, ketones, aldehydes, aromatic hydrocarbons, amines and terpenes (Kuske et al. 2005). The best known indoor bacterial infection is from Legionella, which is associated with the growth of the bacteria in water particularly associated with cooling systems or spas (Diederen 2008). It can even be a problem with domestic electric showers, because although domestic hot water systems are often 60 oC and kill legionella, electric showers are cold water fed. Biologically derived particles can also incorporate allergens. Of particular
© Woodhead Publishing Limited, 2010
Environmental health and safety in buildings
165
concern are those from the dust mite which are associated with asthma and allergy. Allergens are also associated with pets and although pet ownership has increased over time, a Mintel report in June 2005 shows recent declines as people have less time to care for pets and keep them company, particularly in a period where children have many other activities. Dog ownership in Britain fell by 26% between 1985 and 2004, but the outcome in terms of susceptibility to allergens is not easy to predict.
6.9
Materials and toxicity
Modern materials and lifestyles have imposed new risks within occupied spaces and the choice of construction and furnishing materials has become especially difficult. We have to balance the risks imposed by flame retardants, cleaning agents or pesticides against the problems that arise if they have not been used. There is much advice on making such choices, but the reasoning behind such advice is not always obvious. There is a general tendency to regard natural materials as preferable to artificial, on the basis that they have been in use for a long time. Use over a long time is often a good guide as we learn correct approaches to the materials, but it does not seem to make them inherently safe.
6.9.1 Regulation There is a widening regulatory framework that controls the quality of indoor air within occupational, public and domestic spaces. Best known in the UK are the the Building Regulations where Part C concerns resistance to contaminants, Part D to toxic substances and Part F ventilation. Formaldehyde from a number of sources has been of concern and the UK Department for Environment, Food and Rural Affairs pressed for Building Regulations Part D to prohibit the use of UFF in unsuitable buildings and to control its installation and use elsewhere. In parallel there is regulatory concern over formaldehyde from medium density fibreboard, such that in the US emissions must limit yield from MDF to 0.3 ppm and in Germany the exposure limit is 0.l ppm, while Britain’s Health and Safety Executive has issued a number of hazard assessments (e.g. Medium Density Fibreboard – Hazard Assessment Document, EH75/1). Despite the regulatory progress, high levels of formaldehyde are still found when buildings are refurbished, as illustrated by the renovation or construction of schools in Korea where the indoor concentrations of HCHO were higher in schools less than a year old (Yang et al. 2009). Materials such as lead in paint or asbestos have been revealed as problematic, but the range of problem materials is more extensive than this. Asbestos is now well covered by the Control of Asbestos Regulations 2006.
© Woodhead Publishing Limited, 2010
166
Materials for energy efficiency and thermal comfort in buildings
The use of lead pigments in primer paints on some prefabricated domestic wooden windows continued through to the 1980s, but the UK implemented the provisions of an EU Directive (89/677/EEC) and restricts the use of lead paint. The Regulations allow the manufacture and use of lead, but in controlled circumstances for the redecoration of Grade I and II* listed historic buildings, though the general sale of lead paint in the UK is prohibited. Nevertheless, during the redecoration of older houses, paintwork containing lead pigment can be mobilised, so must be treated as a potential health risk. Furthermore, if it is flaking, likely to be chewed by children or animals, additional risks are imposed.
6.10
Advanced material requirements
Those who wish to create buildings with low environmental risk suggest avoiding materials that are likely to produce persistent organic pollutants. These have the potential to accumulate in fatty tissues concentrating as they move up the food chain and to act as endocrine disruptors. Chlorinated building materials, notably the plastics are likely to be associated with chlorinated dibenzodioxins and furans during their manufacture or when they burn. They also advise against brominated flame retardants, particularly polybrominated diphenyl ether and various perfluorocompounds such as Teflon and Scotchguard. The latter has been used to protect furnishings and fabrics. The key ingredient was perfluorooctane sulfonate, although this has now been reformulated with the less persistent perfluorobutane sulfonate. It is suggested that heavy metals are to be avoided, mercury in switches, lead flashing and solder and copper. The choices advocated for interior materials typically focus on the use of natural substances. This approach to the use of flooring materials can potentially make a big change to indoor safety. Natural linoleum is made from linseed, cork, tree resin, limestone and jute. It is biodegradable and anti-microbial. Natural cork flooring is produced from the bark of the cork oak tree and often layered with UV cured acrylic. It is highly durable, comfortable, sound and thermally insulating. In the case of carpeting and furnishing fabrics, wool is often seen as a non-toxic alternative to synthetic fibres which can outgas, but wool releases sulfides (Brimblecombe et al. 1992). Bamboo is seen as a durable, anti-microbial and water resistant material that can be used for floors and walls. As a plywood, it can be used for kitchen cutting boards, plates, bowls, utensils, countertops and walls and furniture. Paints and finishes are preferred where they contain low or no VOCs, no fungicides or biocides and natural pigments or they are from naturallyderived materials such as citrus peel extracts, essential oils, seed oils, tree resins, inert mineral fillers, tree and bee waxes. The careful choice of materials in improving the indoor environment
© Woodhead Publishing Limited, 2010
Environmental health and safety in buildings
167
makes sense, but it must be recognised that even the materials in the recommendations above are not without problems. In particular, a focus on natural resins are a problem as they can produce significant concentrations of highly reactive terpenes as indoor VOCs and the UV curing process can release VOCs (Uhde and Salthammer 2007).
6.11
Future trends
As emphasised in the recent article by Weschler (2009), there have been enormous changes in the pollutants we encounter in air over the last fifty years. These will no doubt continue. It is also hard to appreciate the magnitude of potential social change given what we have witnessed in the last fifty years. Social changes have an impact that is difficult to predict. If we look at the European heat-wave of 2003, it is possible to see that changing family structures affected the stress/death among elderly people in that very hot summer, possibly from indoor ozone. Our lifestyles have also changed with increasing use of computers and entertainment within the home rather than outside. It is hard to predict how our indoor lives will change in the future (time inside, electronics, food, etc.). Furthermore, climate change will impose novel requirements on heating and ventilation systems. There is no doubt that we will see an increasing regulation of consumer products and building materials. It is likely that regulations will develop to establish a wider range of criteria for indoor air quality. Since 2004 South Korea has guidelines for formaldehyde (210 mg m–3), benzene (30 mg m–3), toluene (1000 mg m–3), ethylbenzene (360 mg m–3), xylene (700 mg m–3) and styrene (300 mg m–3) in public buildings as part of the Indoor Air Quality Management Act (Kim et al. 2006). In other countries, including China, Singapore, Canada, United Kingdom and Germany, air quality guidelines have been developed also for the indoor environment, but they are highly variable in terms of the compounds and factors considered. Standards relating to the emissions from materials are increasingly common but in some countries, such as China, rapid development has led to a deterioration of indoor air quality because of the use of new materials, e.g. the extensive use of chipboard with high emissions of formaldehyde. In the future there may be entirely new materials such as nano-dusts from emerging nanotechnology. In parallel we can expect an increase in monitoring of indoor pollutants. Carbon monoxide is a particularly critical indoor pollutant, as it accounts for so many deaths. This has meant a great interest in monitors, which are increasingly common in rooms to detect leaks. Changes in the way we ventilate spaces, the range of materials and modern activities pose new dangers within our buildings. The changes are not all for the worse, but we have to recognise the types of risks our
© Woodhead Publishing Limited, 2010
168
Materials for energy efficiency and thermal comfort in buildings
choices impose. Flame retardants are dangerous and cleaning agents are risky, yet these substances can save lives or reduce the chance of infection. Modern approaches should favour the adoption of materials and processes that lead to the broadest reduction of risk and are compatible with notions of sustainability.
6.12
References
Adonis M and Gil L (2001), ‘Indoor air pollution in a zone of extreme poverty of metropolitan Santiago, Chile’, Indoor and Built Environment, 10, 138–146. Afshari A, Lundgren B and Ekberg LE (2003), ‘Comparison of three small chamber test methods for the measurement of VOC emission rates from paint, Indoor Air, 13, 156–165. Afshari A, Matson U and Ekberg LE (2005), ‘Characterization of indoor sources of fine and ultrafine particles, a study conducted in a full-scale chamber’, Indoor Air, 15, 141–150. Andersson B, Markert F and Holmstedt G (2005), ‘Combustion products generated by hetero-organic fuels on four different fire test scales’, Fire Safety Journal, 40, 439–465. Belitz H-D, Grosch W (1992), Lehrbuch der Lebensmittelchemie, Springer, Berlin. Bhushan B and Chandra S (1999), ‘Detection and sizing of particulate contamination in rigid disk drives: instruments and sampling techniques’, IEEE Transactions on Magnetics, 35, 956–962. Boucher M, Ehmler TJ and Bermudez AJ (2000), ‘Polytetrafluoroethylene gas intoxication in broiler chickens’, Avian Diseases, 44, 449–453. Boutin M, Lesage J, Ostiguy C, Pauluhn J and Bertrand MJ (2004), ‘Identification of the isocyanates generated during the thermal degradation of a polyurethane car paint’, Journal of Analytical and Applied Pyrolysis, 71, 791–802. Brasche S and Bischof W (2005), ‘Daily time spent indoors in German homes: baseline data for the assessment of indoor exposure of German occupants’, International Journal of Hygiene and Environmental Health, 208, 247–253. Brimblecombe P (1990), ‘Composition of museum atmospheres’, Atmospheric Environment, 24B, 1–8. Brimblecombe P (2008), ‘Understanding the composition of museum air’, Zeitschrift für Kunsttechnologie und Konservierung, 22, 235–239. Brimblecombe P, Shooter D and Kaur A (1992), ‘Wool and reduced sulphur gases in museum air’, Studies in Conservation, 37, 53–60. Brimblecombe N, Dorling D and Shaw M (1996), ‘Where the poor die in a rich city: the case of Oxford’, Health and Place, 5, 287–300. Brimblecombe P, Blades N, Camuffo D, Sturaro G, Valentino A, Gysels K, Van Grieken R, Busse H-J, Kim O, Ulrych U and Wieser M (1999), ‘The indoor environment of a modern museum building, the Sainsbury Centre for Visual Arts, Norwich, UK’, Indoor Air, 9, 146–164. CABE (2007), Living with risk – Promoting better public space design, London, WHO. Camuffo D, Brimblecombe P, Van Grieken R, Busse H, Sturaro G, Valentino A, Bernardi A, Blades N, Shooter D, De Bock L, Gysels K, Wieser M and Kim O (1999), ‘Indoor air quality at the Correr Museum, Venice, Italy’, Science of the Total Environment, 236, 135–152.
© Woodhead Publishing Limited, 2010
Environmental health and safety in buildings
169
Cano-Ruiz JA, Kong D, Balas RB and Nazaroff WW (1992), ‘Removal of reactive gases at indoor surfaces: combining mass transport and surface kinetics’, Atmospheric Environment, 27, 2039–2050. Chang FH, Lin TC, Huang CI, Chao HR, Chang TY and Lu CS (1995), ‘Emission characteristics of VOCs from athletic tracks’, Journal of Hazardous Materials, 23, 1–20. Clark LA, Hastie T, Psotakelty LA, Sinclair JD and Rauchut J (1992), ‘Sources of particle contamination in an IC manufacturing environment’, Aerosol Science and Technology, 16, 43–50. Diederen BMW (2008), ‘Legionella spp. and Legionnaires’ disease’, Journal of Infection, 56, 1–12. Edwards RD, Jurvelin J, Koistinen K, Saarela K and Jantunen M (2001), ‘OC source identification from personal and residential indoor, outdoor and workplace microenvironment samples in EXPOLIS – Helsinki, Finland’, Atmospheric Environment, 35, 4829–4841. Fan ZH, Lioy P, Weschler C, Fiedler N, Kipen H and Zhang JF (2003), ‘Ozone-initiated reactions with mixtures of volatile organic compounds under simulated indoor conditions’, Environmental Science and Technology, 37, 1811–1821. Farrow A, Taylor H, Northstone K and Golding J (2003), ‘Symptoms of mothers and infants related to total volatile organic compounds in household products’, Archives of Environmental Health, 58, 633–641. Franklin P (2007), ‘Indoor air quality and respiratory health of children’, Paediatric Respiratory Reviews, 8, 281–286. Grontoft T and Raychaudhuri MR (2004), ‘Compilation of tables of surface deposition velocities for O-3, NO 2 and SO2 to a range of indoor surfaces’, Atmospheric Environment, 38, 533–544. Gunschera J, Fuhrmann F, Salthammer T, Schulze A and Uhde E (2004), ‘Formation and emission of chloroanisoles as indoor pollutants’, Environmental Science and Pollution Research, 11, 147–151. Hartzell GE (2001), ‘Engineering analysis of hazards to life safety in fires: the fire effluent toxicity component’, Safety Science, 38, 147–155. Hodgson AT and Levin H (2003), Volatile Organic Compounds in Indoor Air: a Review of Concentrations Measured in North America Since 1990, Lawrence Berkeley National Laboratory Report, LBNL–51715. Hodgson AT, Wooley JD and Daisey JM (1993), ‘Emissions of volatile organic compounds from new carpets measured in a large-scale environmental chamber’, Journal of the Air and Waste Management Association, 43, 316–324. Hodgson AT, Beal D and McIlvaine JER (2002), ‘Sources of formaldehyde, other aldehydes and terpenes in a new manufactured house’, Indoor Air, 12, 235–242. Horn W (1998), ‘VOC emissions from cork products for indoor use’, Indoor Air, 8, 39–46. Houck PM and Hampson NB (1997), ‘Epidemic carbon monoxide poisoning following a winter storm’, Journal of Emergency Medicine, 15, 469–473. Hull TR, Lebek K, Pezzani M and Messa S (2008), ‘Comparison of toxic product yields of burning cables in bench and large-scale experiments’, Fire Safety Journal, 43, 140–150. Hyttinen M, Pasanen P, Bjorkroth M and Kalllokoski P (2007), ‘Odors and volatile organic compounds released from ventilation filters’, Atmospheric Environment, 41, 4029–4039.
© Woodhead Publishing Limited, 2010
170
Materials for energy efficiency and thermal comfort in buildings
Janssen NAH, van Vliet PHN, Aarts F, Harssema H and Brunekreef B (2001), ‘Assessment of exposure to traffic related air pollution of children attending schools near motorways’, Atmospheric Environment, 35, 3875–3884. Jensen B, Wolkoff P, Wilkins CK and Clausen PA (1995a), ‘Characterization of linoleum. Part 1: measurement of volatile organic compounds by use of the field and laboratory emission cell, ‘FLEC’, Indoor Air, 5, 38–43. Jensen B, Wolkoff P and Wilkins CK (1995b), ‘Characterization of linoleum. Part 2: preliminary odor evaluation’, Indoor Air, 5, 44–49. Kavi Kumar KS and Viswanathan B (2007), ‘Changing structure of income indoor air pollution relationship in India’, Energy Policy, 35, 5496–5504. Kim SS, Kang DH, Choi DH, Yeo MS and Kim KW (2006), ‘Comparison of strategies to improve indoor air quality at the pre-occupancy stage in new apartment buildings’, Building and Environment, 43, 320–328. Klitzman S, Caravanos J, Belanoff C and Rothenberg L (2005), ‘A multihazard, multistrategy approach to home remediation: results of a pilot study’, Environmental Research, 99, 294–306. Kuske M, Romain A-C and Nicolas J (2005), ‘Microbial volatile organic compounds as indicators of fungi. Can an electronic nose detect fungi in indoor environments?’, Building and Environment, 40, 824–831. Leaderer BP (1982), ‘Air pollutant emission from kerosene stove’, Science, 218, 1113–1115. Lebens JA, McColgin WC, Russell JB, Mori EJ and Shive LW (1996), ‘Unintentional doping of wafers due to organophosphates in the clean room ambient’, Journal of the Electrochemical Society, 143, 2906–2909. Liu QT, Chen R, McCarry BE, Diamond ML and Bahavar B (2003), ‘Characterization of polar organic compounds in the organic film on indoor and outdoor glass windows’, Environmental Science and Technology, 37, 2340–2349. Lloyd H, Brimblecombe P and Lithgow K (2007), ‘The economics of dust’, Studies in Conservation, 52, 135–146. Manninen AM, Pasanen P and Holopainen JK (2002), ‘Comparing the VOC emissions between air-dried and heat-treated Scots pine wood’, Atmospheric Environment, 36, 1763–1768. Melia RJ, Florey CD, Chinn S, Morris RW, Goldstein BD, John HH and Clark D (1985), ‘Investigations into the relations between respiratory illness in children, gas cooking and nitrogen dioxide in the UK’, The Tokai Journal of Experimental and Clinical Medicine, 10, 3775–3787. Muller AJ, Psotakelty LA, Krautter HW and Sinclair JD (1994), ‘Volatile cleanroom contaminants – sources and detection’, Solid State Technology, 37, 61. Ni Y, Kumagai K and Yanagisawa Y (2007), ‘Measuring emissions of organophosphate flame retardants using a passive flux sampler’, Atmospheric Environment 41, 3235–3240. Pandit GG, Srivastava PK and Mohan Rao AM (2001), ‘Monitoring of indoor volatile organic compounds and polycyclic aromatic hydrocarbons arising from kerosene cooking fuel’, Science of the Total Environment, 279, 159–165. Pluschke P (ed.) (2004), Indoor Air Pollution, Berlin, Springer. Poppendieck DG, Hubbard HF, Weschler CJ and Corsi RL (2007), ‘Formation and emissions of carbonyls during and following gas-phase ozonation of indoor materials’, Atmospheric Environment, 41, 7614–7626. Raub JA, Mathieu-Nolf M, Hampson NB and Thom SR (2008), ‘Carbon monoxide poisoning: a public health perspective’, Toxicology, 145.
© Woodhead Publishing Limited, 2010
Environmental health and safety in buildings
171
Reiss R, Ryan PB, Koutrakis P and Tibbetts SJ (1995), ‘Ozone reactive chemistry on interior latex paint’, Environmental Science and Technology 29, 1906–1912. Salthammer T (1995a), ‘Emission of volatile organic compounds from furniture coatings’, Indoor Air, 7, 189–197. Salthammer T (1995b), ‘Volatile organic ingredients of household and consumer, products’, in Salthammer T (ed.), Organic Indoor Air Pollutants, Weinheim, Wiley VCH, 219–232. Salthammer T, Fuhrmann F, Uhde E (2003), ‘Flame retardants in the indoor environment – Part II: Release of VOCs (triethylphosphate and halogenated degradation products) from polyurethane’, Indoor Air, 13, 49–52. Sherman MH (1999), Air Change Rate and Airtightness in Buildings, Vol STP 1067. West Conshohocken, PA, ASTM International. Shields HC and Weschler CJ (1992), ‘Volatile organic compounds measured at a telephone switching center from 5/30/85–12/6/88 – a detailed case study’, Journal of the Air and Waste Management Association, 42, 792–804. Smith KR, Samet JM, Romieu I and Bruce N (2000), ‘Indoor air pollution in developing countries and acute lower respiratory infections in children’, Thorax, 55, 518–532. Spyak PR and Wolfe WL (1992), ‘Scatter from particulate-contaminated mirrors. 3. Theory and experiment for dust and lambda = 10.6 mm’, Optical Engineering, 31, 1764–1774. Toftum J, Freund S, Salthammer T and Weschler CJ (2008), ‘Secondary organic aerosols from ozone-initiated reactions with emissions from wood-based materials and a green paint’, Atmospheric Environment, 42, 7632–7640. Toishi K and Kenjo T (1967), ‘Some aspects of the conservation of art works in buildings of new concrete’, Journal of Paint Technology, 39, 52–55. Toishi K and Kenjo T (1975), ‘Some aspects of the conservation of art works in buildings of new concrete’, Studies in Conservation, 20, 118–122. Uhde E and Salthammer T (2007), ‘Impact of reaction products from building materials and furnishings on indoor air quality – a review of recent advances in indoor chemistry’, Atmospheric Environment, 41, 3111–3128. Van Loy MD, Riley WJ, Daisey JM and Nazaroff WW (2001), Dynamic behavior of semivolatile organic compounds in indoor air. 2. Nicotine and phenanthrene with carpet and wallboard, Environmental Science and Technology, 35, 560–567. Verschueren K (1996), Handbook of Environmental Data on Organic Chemicals, New York, Wiley. Wang H and Morrison GC (2006), ‘Ozone-initiated secondary emission rates of aldehydes from indoor surfaces in four homes’, Environmental Science and Technology, 40, 5263–5268. Wang S, Ang HM and Tade MO (2007), ‘Volatile organic compounds in indoor environment and photocatalytic oxidation: state of the art’, Environment International, 33, 694–705. Watling R and Harper DB (1998), ‘Chloromethane production by wood-rotting fungi and an estimate of the global flux to the atmosphere’, Mycological Research, 102, 769–787. Wensing M, Uhde E and Salthammer T (2003), ‘Plastics additives in the indoor environment – flame retardants and plasticizers’, Science of the Total Environment, 339, 9–40. Weschler CJ (2009) ‘Changes in indoor pollutants since the 1950s’, Atmospheric Environment, 43, 153–169. Weschler CJ and Shields HC (1997), ‘Potential reactions among indoor pollutants’, Atmospheric Environment, 31, 3487–3495. © Woodhead Publishing Limited, 2010
172
Materials for energy efficiency and thermal comfort in buildings
Weschler CJ and Shields HC (1999), ‘Indoor ozone/terpene reactions as a source of indoor particles’, Atmospheric Environment, 33, 2301–2312. Weschler CJ, Hodgson AT and Wooley JD (1992), ‘Indoor chemistry – ozone, volatile organic compounds, and carpets’, Environmental Science and Technology, 26, 2371–2377. WHO (2006), Development of WHO Guidelines for Indoor Air Quality, Copenhagen, World Health Organization Regional Office for Europe. Wolkoff P, Schneider T, Kildesø J, Degerth R, Jaroszewski M and Schunk H (1998), ‘Risk in cleaning: chemical and physical exposure’, Science of the Total Environment, 215, 135–156. Won D, Sander DM, Shaw CY and Corsi RL (2001), ‘Validation of the surface sink model for sorptive interactions between VOCs and indoor materials’, Atmospheric Environment, 35, 4479–4488. Yang W, Sohn J, Kim J, Son B and Park J (2009), ‘Indoor air quality investigation according to age of the school buildings in Korea’, Journal of Environmental Management, 90, 348–354. Zhao Y, Hu M, Slanina S and Zhang Y (2007), ‘The molecular distribution of fine particulate organic matter emitted from Western-style fast food cooking’, Atmospheric Environment, 41, 8163–8171.
© Woodhead Publishing Limited, 2010
7
Life cycle assessment and environmental profiling of building materials
K. S t e e l e, Arup: Façades and Materials, UK
Abstract: Sustainability is a complex challenge facing the world today. It requires a holistic approach to thinking which brings together social, economic and environmental dimensions. The built environment, with its vast consumption of energy and resources, and resultant emissions has an important role to play in meeting this challenge. It follows that the manufacture and supply of building materials must contribute to this. Within this context, life cycle thinking and the examination of materials’ embodied impact must go hand in hand with a broader agenda including healthy and safe materials, responsible sourcing and good resource management. This chapter examines these issues taking a focused look at embodied impacts and the use of life cycle assessment (LCA) as an important tool with which to address the environmental sustainability of our building fabric. Key words: construction products and materials, life cycle assessment, LCA, embodied impact, healthy and safe materials, responsible sourcing, resource management, sustainability, environment, ISO, CEN and BSI standardisation.
7.1
Materials sustainability
Sustainability in the context of modern development is a term that transcends the original definition of the word. It is therefore briefly important to examine what it means. From a qualitative perspective, sustainability is, by definition, something that has the ability for continuance, in essence, the ability to keep itself going. This is a simple concept to grasp. However, within the context of our developing society it has developed into a hugely complex debate and agenda. The reason for this is that the term has become synonymous with the very existence of humanity, and with our (logical and rightful) desire for continuance. To sustain life on earth, the global environment must be sustainable, for, as Sarah Parkin (2000) bluntly puts it, ‘if the environment cannot support life, then we are dead’. For hundreds of millions of years, the world has successfully supported and sustained life (and more recently, human life). Unfortunately, evidence now indicates that the global environment could be losing its qualities of sustainability. Indeed, it is now widely recognised that humanity’s existence as we know it is threatened. 175 © Woodhead Publishing Limited, 2010
176
Materials for energy efficiency and thermal comfort in buildings
This has prompted concern that the world will develop into an unattractive and perhaps uninhabitable place in which to live. The underlying blame can be attributed to human activities and their burden on the environment. It follows that human activities are unsustainable; they are causing potentially irreversible damage and it is now widely recognised that this problem must be addressed. This is a complex and global challenge that requires a reexamination of how we do things in all walks of life. The built environment, with its vast consumption of energy and resources and resultant emissions, in construction, operation, and at end-of-life has an important role to play. This is well recognised and the drive is now on to design, construct and manage our built environment in a way that is sustainable. The manufacture and supply of materials has an important contribution to make to this objective and the sustainability of building materials and construction products has become an issue against which we should judge our building fabric. But what does this mean and how do we allow for this complex agenda in materials selection, specification and procurement? The start point is to recognise that sustainable decision making requires that environmental, social and economic dimensions are brought together in a holistic approach considering multiple criteria within a life cycle context. Therefore this enables technical performance of a material to be examined alongside its impacts. Within this context it should be recognised that both the benefits and impacts a material has occur across all three environmental, social or economic dimensions. Slowly the industry is establishing tools and methods for this new framework of assessment. This chapter takes a focused look at one of these tools called life cycle assessment (LCA), as well as introducing the concepts of healthy materials, responsible sourcing and resource management and how they are expected to play an increased role in the next period in the assessment of sustainable materials.
7.2
A life cycle approach to selecting building materials
Commonly referred to as ‘cradle-to-grave’ or ‘cradle-to-cradle’ assessment, life cycle assessment, or LCA, examines the life cycle of a product, system or process and evaluates the environmental impact it has over its life or a defined study period. In this regard LCA follows two key principles important to sustainable decision making. These are a ‘systems’ approach to assessment, i.e. it assesses life cycle performance; and secondly evaluation across multicriteria, i.e. performance is measured across multiple environmental impact categories (Fig. 7.1). Both are fundamental to making environmentally sustainable decisions.
© Woodhead Publishing Limited, 2010
Life cycle assessment and environmental profiling
177
Inputs: energy, water, materials, land
Raw materials
Production
Distribution and retail Consumer use
End of life Outputs: greenhouse gases, air emissions, effluent, solid waste Result: climate change, resource depletion, air, water and soil pollution Example environmental impact categories is not definitive. ∑ Climate change ∑ Ozone layer depletion ∑ Human toxicity ∑ Freshwater aquatic ecotoxicity ∑ Terrestrial ecotoxicity ∑ Photochemical oxidation ∑ Acidification
often assessed in LCA; this list ∑ ∑ ∑ ∑ ∑ ∑ ∑
Eutrophication Fossil fuel depletion Solid waste Radioactivity Mineral resource depletion Water use or extraction Land use
7.1 Life cycle assessment has two key strengths as an environmental sustainability assessment tool. These are that it can follow a cradleto-grave or even a cradle-to-cradle assessment approach, i.e. it works on a ‘life cycle’ basis; and secondly it can study a system against a broad selection of environmental impacts, which can include headline issues such as climate change (i.e. as commonly recognised by ‘embodied carbon’ or ‘embodied CO2’); but also embodied waste, embodied water, etc. Life cycle thinking and multi-criteria are fundamental to making environmentally sustainable decisions.
7.3
A brief history of life cycle assessment (LCA)
The history of LCA is well documented (Hunt and Franklin, 1996); Boustead, 1996). As a concept, it has its roots in the late 1960s and early 1970s when the idea was first envisioned to quantify the environmental consequences of Coca-Cola beverage packaging options over a life cycle in terms of energy, transport, waste, materials, etc. Despite this, it was not until the 1990s that a recognised methodology for LCA emerged. This was largely delivered through a body of work supported by The Society of Environment Toxicology and Chemistry (SETAC).
© Woodhead Publishing Limited, 2010
178
Materials for energy efficiency and thermal comfort in buildings
Following these initiatives international standards for LCA started to emerge in the mid-1990s through work organised by the International Organisation for Standardisation (ISO). The subsequent BS EN ISO 14040 Series entitled ‘Environmental management – life cycle assessment’ represents the first complete and internationally accepted standardisation of LCA technique and methodology. Despite these developments and the fact that the concept of LCA is more than 40 years old and hence is relatively mature, its use to model and communicate the environmental impact of different assessed scenarios until recently remained relatively unusual. This is perhaps due to its complexity, and data intensive nature which makes any programme of assessment a time- and capital-intensive exercise. All this is starting to change, and in the last five years LCA has started to move into the mainstream with many construction industry stakeholders taking an interest. Before we move on to consider the Standards framing this context, it is first worth briefly exploring ‘environmental labelling’ and where LCA sits within this.
7.4
Environmental labelling
The ISO 14000 series is the family of standards which have been developed to address environmental management. Their scope is broad and encompasses many different strands, but generally speaking two key branches can be identified. These are standards which are organisation oriented, and those which are product oriented. The organisation orientated standards provide guidance for establishing, maintaining and evaluating environmental management systems (EMS). By contrast, the product oriented standards are primarily concerned with determining the environmental aspects and impacts of products and have been developed for the application of environmental labels and declarations associated with them. The framework for product environmental labelling and declaration is standardised in BS EN ISO 14020. This is a general principles document which further identifies three ‘Types’ of label/declaration/claim. A summary of this framework is provided in Table 7.1. Each declaration ‘Type’ is supported by a separate ISO Standard which has been developed to further harmonise practice. BS EN ISO 14020 and its complementary standards are intended to help an organisation gather the information needed to support planning for, and decision making on, its product/service and to communicate specific environmental information about that product/service to its stakeholders. It is important to recognise that LCA information might form content in any of the three identified label or declaration Types, but that with Type III labelling, an LCA approach must be used. Of the three Types of environmental label, it is Type III and its use of LCA which lends itself most readily to
© Woodhead Publishing Limited, 2010
Life cycle assessment and environmental profiling
179
Table 7.1 Environmental labelling and declaration according to BS EN ISO 14020 Type I Third Party Environmental labelling BS EN ISO 14024:2001
Label: a voluntary, multi-criteria based third party programme/standard that awards a licence which authorises the use of environmental labels on products indicating overall environmental preference of a product within a particular product category based on life cycle considerations. These are commonly referred to as ‘ecolabels’ (e.g. environmental labels like Blue Angel, Nordic Swan and European Eco-Label)
Type II Self-declared environmental claims BS EN ISO 14021:2001
Claim: a self-declared environmental claim is a statement, symbol or graphic that indicates an environmental aspect of a product (e.g. self-declaration claiming a material or product such as a brick or concrete block to be recyclable, or alternatively to incorporate recycled content)
Type III Third Party verified Environmental Product Declaration (EPD) BS EN ISO 14025:2006
Declaration: a set of quantified environmental data consisting of pre-set parameters (so-called ‘nutritional label’) based on LCA according to the BS EN ISO 14040 series of standards, with at least a minimum set of parameters for the product group (e.g. EPD with a mandatory third party validation: IBU or BRE Environmental Profiles).
considering environmental sustainability of materials. This is because it can take account of life cycle impacts and assessment across multiple issues. The chapter now looks at LCA and the steps for undertaking an assessment.
7.5
Life cycle assessment (LCA) of building materials
LCA can provide a holistic and comprehensive method for assessing environmental performance because it can apply a life cycle-based approach to investigation. It can be used to identify where environmental impacts are arising within a system’s life cycle, and offer a process for examining opportunities for improving performance. In this context, LCA is best described as a form of ‘systems analysis’. In construction, the system could be a material manufacture process; the fabrication of a building; a building element such as an external wall; an entire building or civil asset over its life; or even a neighbourhood consisting of all of the above. This flexibility means that LCA can be applied to specific built assets or service requirements such as waste management practice, transport scenarios or energy provision.
© Woodhead Publishing Limited, 2010
180
Materials for energy efficiency and thermal comfort in buildings
7.5.1 LCA methodologies and product category rules (PCR) An LCA methodology, or more specifically a PCR, is a record of the specific rules which govern how an LCA should be undertaken for one or more ‘product categories’. Commonly, a PCR is developed for a defined product category which is a ‘group of products that can fulfil equivalent functions’. The PCR will be developed with a specific goal and scope in mind. It should be followed to ensure that the LCA is fair, consistently applied, and that the results can be used comparatively. The PCR will define: ∑ the predetermined LCA environmental impact categories ∑ rules on reporting additional environmental information ∑ calculation process, including requirements for data quality, verification procedure, allocation method, declared and functional units, inventory analysis method, cut off rules, boundary conditions, etc. ∑ general requirements for reporting and communicating the LCA. Importantly, the PCR will also state the three-step process for undertaking an LCA including characterisation, normalisation and weighting procedure.
7.5.2 Characterisation In very simple terms LCA is about modelling system flows. Called ‘inventory flows’, these are the environmental interventions that take place between the study system, and the environment around it. They consist of all the inputs and outputs to the study system and include extraction of raw materials and fuels, requirement for heat and water consumption, and emissions to air, discharges to water and emissions to land. The linkage of these inventory flows to environmental impacts happens through a process that ‘characterises’ inventory flows (also known as inventories or interventions), into predefined categories of environmental impact (e.g. CO2, methane, CFCs and N2O all contribute to global warming potential). An important component of characterisation is the use of characterisation factors which recognise that emissions have different contribution levels to impact categories (Fig. 7.2). In Acid rain
Sulphur dioxide
Carbon dioxide
1
Global warming
21 Methane
Summer smog
7.2 Example of LCA characterisation; methane has 21 times more global warming potential than carbon dioxide. This means a characterisation factor of 21 is applied.
© Woodhead Publishing Limited, 2010
Life cycle assessment and environmental profiling
181
this step of an LCA it is possible to determine the magnitude of environmental impacts attributed to a system.
7.5.3 Normalisation Normalisation is the calculation of the magnitude of the impact category characterised data as set against a relative reference value. Normalisation can be used to bring a degree of relativity to LCA findings. Typically this is done by dividing the characterised impact figure values by comparable impact category figures, but determined for a reference geographic area per head of population over a defined time period. This figure could be used to normalise characterised impact data for global warming potential (climate change). An outcome of normalisation is better understanding of the relative magnitude of each impact result of the studied system, but also preparation of the LCA findings for an additional procedure of weighting.
7.5.4 Weighting Weighting, also known as valuation, is a process of assigning a degree of significance to the normalised impact category data. This is done by multiplying the normalised data by numerical factors (i.e. from a total of 100%). These factors are typically based on value choices, i.e. an opinion on which environmental impact category is more important than another. Weighted impact category results can be left disaggregated or added together to a single ‘score’ of environmental performance. It is important to recognise that weighting steps are based on value choices which may not be scientifically based. BRE conducted a weightings exercise for its LCA environmental profile methodology in 2007 (Aizlewood et al., 2007; Hamilton et al., 2007). The weightings derived from this are shown in Table 7.2.
7.5.5 LCA data/life cycle inventory (LCI) information The input/output data defined in LCA models is called life cycle inventory (LCI) data. There are many commercially available LCI datasets which can be accessed for LCA modelling. Key databases include: ∑ Ecoinvent: produced for the Swiss Government www.ecoinvent.ch ∑ Boustead: produced by a UK-based LCA consultancy www.boustead-consulting.co.uk ∑ GaBi: produced by PE Consulting www.gabi-software.com
© Woodhead Publishing Limited, 2010
182
Materials for energy efficiency and thermal comfort in buildings Table 7.2 Weighting factors for the 2008 Environmental Profiles Methodology
∑ ∑ ∑ ∑ ∑
Environmental Issue
Weighting (%)
Climate change Water extraction Mineral resource extraction Stratospheric ozone depletion Human toxicity Ecotoxicity to water Nuclear waste Ecotoxicity to land Waste disposal Fossil fuel depletion Eutrophication Photochemical ozone creation Acidification
21.6 11.7 9.8 9.1 8.6 8.6 8.2 8.0 7.7 3.3 3.0 0.20 0.05
IDEMAT: produced by TU Delft www.idemat.nl IVAM: produced by the University of Amsterdam www.ivam.nl Franklin: produced by Franklin Associates in the USA www.fal.com ETH-ESU: produced by ESU services in Switzerland www.esu-services.ch BUWAL: produced by the Swiss Government www.bafu.admin.ch
In addition there are numerous sector specific, and regionally specific, initiatives which have developed to gather LCI or assist with the harmonisation of LCA. From an EU perspective, the Platform project on LCA delivered through the European Commission Joint Research Centre: Institute for Environment and Sustainability (http://lca.jrc.ec.europa.eu/lcainfohub/directory.vm) is a significant initiative. It has the twin objectives of developing an international reference life cycle database as well as an international resources directory and discussion forum for LCA. It also provides links to more widely available LCA data and tools: ∑ ∑
Data: http://lca.jrc.ec.europa.eu/lcainfohub/databaseList.vm Tools: http://lca.jrc.ec.europa.eu/lcainfohub/toolList.vm
7.6
Life cycle assessment (LCA) standardisation
Undertaking environmental life cycle modelling using LCA is a complex process which provides the practitioner with great flexibility to define and
© Woodhead Publishing Limited, 2010
Life cycle assessment and environmental profiling
183
set specific methodological rules. The disadvantage with this flexibility is the potential to create LCA models which are not comparable; or in worst case scenarios, develop LCA which are inherently biased, but which appear at face value entirely sound. To help harmonise LCA application and set common rules, the International Standards Organisation has developed a series of standards for the use of LCA. In addition, the European Committee for Standardisation (CEN) is coordinating the development of a construction sector set of LCA standards. A brief summary to the ISO and CEN work is now provided.
7.6.1 International Standards Organisation (ISO) ISO has been active in the development of LCA standards since the mid1990s. There now exist a range of standards for the generic application of LCA, through to its specific use in the construction sector. ISO 14040 series: Environmental management – life cycle assessment The ISO 14040 series were originally published in 1997 to harmonise the application of LCA. There are currently two1 standard documents2: ∑ ∑
BS EN ISO assessment – BS EN ISO assessment –
14040:2006, Environmental management – life cycle principles and framework. 14044:2006, Environmental management – life cycle requirements and guidelines.
The difference between the two documents is that ISO 14040 provides a general introduction to the principles of LCA and LCI; by contrast, ISO 14044 sets out specific requirements. Both documents adopt a similar structure organising content under a consistent set of key issues including: ∑ the goal and scope definition of the LCA ∑ the life cycle inventory analysis phase ∑ the life cycle impact assessment (LCIA) phase ∑ the life cycle interpretation phase ∑ reporting and critical review of the LCA ∑ limitations of the LCA 1 There are actually three documents but ‘DD ISO/TS 14048:2002 Environmental management – life cycle assessment – data documentation format’ is only a draft for development (DD) technical specification (TS) which outlines formatting requirements for LCA data documentation. 2 ISO 14040:2006 and ISO 14044:2006 supersede EN ISO 14040:1997, EN ISO 14041:1998, EN ISO 14042:2000, EN ISO 14043:2000.
© Woodhead Publishing Limited, 2010
184
∑ ∑
Materials for energy efficiency and thermal comfort in buildings
relationship between the LCA phases conditions for use of value choices and optional elements
ISO 14025: Type III environmental declarations and programmes As the use of LCA has evolved, and its reporting has become more widespread, specific labelling programmes which model production systems and label products have been established. These programmes are known as Type III Environmental Product Declaration (EPD) labelling schemes. The requirements for their establishment, management, delivery and reporting are set out in BS EN ISO 14025 (2006). LCA product data can be a useful source of environmental information to the building designer and Type III labelling schemes are a potential source for this information. ISO 14025 supports this through providing a set of ‘principles and procedures’ for establishing such labelling programmes and how their operators should use the LCA ISO 14040 series. In this regard, ISO 14025 sets out guidance for developing the PCR, programme operator responsibilities, ensuring comparability, verification procedures, transparency, reporting requirements; to name a few issues. ISO and LCA in construction Although LCA is now widely used across many industrialised systems, very few are supported by standards. The construction industry is an exception as it benefits from a suite of international standards dealing with sustainability in building and construction that include: ∑ ∑
ISO 15392 Sustainability in building construction – general principles ISO 21932 Buildings and constructed assets – sustainability in building construction – terminology ∑ ISO/TS 21929-1 Sustainability in building construction – sustainability indicators – Part 1: Framework for development of indicators for buildings ∑ ISO/TS 21931-1 Sustainability in building construction – framework for methods of assessment for environmental performance of construction works – Part 1: Buildings. Figure 7.3 shows the relationship of these different documents and how they relate to ISO 21930, a standard that sets out the principles for using LCA for the environmental declaration of building products. This means it provides a useful additional focus from the ISO 14040 series, by addressing specific issues of relevance to construction such as the service life of the building products as seen over a building’s life cycle. ISO 21930 is designed
© Woodhead Publishing Limited, 2010
Life cycle assessment and environmental profiling Environmental aspects
Economic aspects
185
Social aspects
ISO/FDIS 15392 : Sustainability in building construction – General principles ISO/TR 21932 : Terminology Methodical basics ISO/TS 21929-1 : Sustainability Indicators – Part 1 : Framework for development of indicators for buildings
Buildings
ISO/TS 21931-1 : Framework for methods of assessment of environmental performance of construction works – Part 1: Buildings
Building products
ISO 21930 : Environmental declaration of building products
7.3 Suite of related international standards for sustainability in building construction and construction works (BS EN ISO 21930, 2007). Permission to reproduce extracts from BS EN ISO 21930 (2007) is granted by BSI. British Standards can be obtained in PDF or hard copy formats from the BSI online shop: www.bsigroup.com/Shop or by contacting BSI Customer Services for hard copies only: Tel: +44 (0)20 8996 9001, Email:
[email protected].
to be used in combination with ISO 14025 as the basis for establishing Type III environmental declaration programmes. Inherent in LCA modelling is the consideration of the study system ‘life cycle’. For buildings and building components this is particularly challenging because they can exhibit long service lives, sometimes extending over tens or hundreds of years. To bring consistency to this complex area, LCA practitioners are increasingly using the ISO 15686 series of standards on ‘service life planning of constructed assets’. The relationship of these standards and ISO LCA frameworks is shown in Fig. 7.4. In this context perhaps the most important standard for LCA is BS ISO 15686-8:2008 Buildings and constructed assets – service-life planning Part 8: Reference service life and service-life estimation. This standard provides guidance on how to select or determine a construction component ‘reference service life’ (RSL) and how to use this for the purposes of calculating an ‘estimated service life’ (ESL). As a defined time period, ESL can be used to represent the service life period of a construction component and when it will reach its end-of-life in an LCA model.
© Woodhead Publishing Limited, 2010
186
Materials for energy efficiency and thermal comfort in buildings
Reference service life and service-life estimation (ISO 15686-8)
Service life prediction procedures (ISO 15686-2)
General principles (ISO 15686-1)
Process modelling and stochastical data
Performance audlts and reviews (ISO 15686-3)
Performance data (ISO 15686-4)
Service life planning of buildings and constructed assets (ISO 15686)
Life cycle assessment (ISO 14040)
Planned and reactive maintenance
Life cycle costs (LCC) (ISO 15686-5)
Facilities management
Demolltion and reuse
7.4 Inputs and influences on service life planning of buildings (adapted from BS EN ISO 15686-1, 2000). Permission to reproduce extracts from BS EN ISO 15686-1 (2000) is granted by BSI. British Standards can be obtained in PDF or hard copy formats from the BSI online shop: www.bsigroup.com/Shop or by contacting BSI Customer Services for hard copies only: Tel: +44 (0)20 8996 9001, Email:
[email protected].
ISO and comparability A key observation of the ISO work is that despite providing a useful framework for modelling, the standards still provide significant room for interpretation by the user (they are designed in this way due to the international and multidisciplinary context in which they will be applied). This means that although studies conducted within their standardised framework should follow a logical path and offer a degree of consistency, they still offer significant opportunity: ∑ ∑
to adopt entirely valid, but differing approaches to introduce bias through manipulation of the LCA methodology towards a particular outcome ∑ for Type III labelling schemes to apply LCA in different ways.
In conclusion, LCA conducted by different practitioners within the ISO
© Woodhead Publishing Limited, 2010
Life cycle assessment and environmental profiling
187
standards are unlikely to be directly comparable (and this includes construction focused standards).
7.6.2 European committee for standardisation (CEN) Many ‘built environment/construction works’ EPD schemes now exist in Europe following the ISO standards. Most of these incorporate common elements but due to the flexibility of the ISO standards, the PCR they follow and the EPD that they produce are different from country to country. To avoid barriers to trade of goods and services, European harmonisation is necessary. This agenda became the subject of a CEN Mandate, under instruction from the EU Enterprise Directorate. The Mandate was written to develop a harmonised approach for ‘sustainability of construction works’ of which LCA would be an important part. The mandate was accepted in late 2004 and work on the standards began in 2005. In response to the mandate, Technical Committee TC350 was established by CEN to develop ‘horizontal standardised methods for the assessment of the integrated environmental performance of buildings’. Although the original mandate extended only to ‘environmental performance of buildings’, the work has subsequently been broadened to consider socio-economic aspects as well. TC350 consists of five Working Groups under the leadership of a single Task Group; the work programme is split horizontally into framework, building and product levels; and vertically into environmental, social and economic dimensions. The initiative will deliver European Standards (EN), Technical Reports (TR) and Technical Specifications (TS). Through TC350 the goal of the Commission is to provide a method for the voluntary delivery of environmental information that supports the construction of sustainable works including new and existing buildings.
7.7
UK context
LCA is increasingly being used in the UK construction sector. Material suppliers use it to assess the environmental impact of their supply chains and production systems; and building designers and constructors are applying it to understand the impact of their constructed assets. Clients are increasingly becoming familiar with the data LCA can present and are considering it in their procurement decisions. Building ratings systems including BREEAM and the Code for Sustainable Homes also indirectly apply LCA through their use of the Green Guide to Specification as a compliance tool. Even CEEQUAL the civil engineering assessment methodology provides reward for the application of LCA to measure embodied impacts of civil works. There is no British Standard or
© Woodhead Publishing Limited, 2010
188
Materials for energy efficiency and thermal comfort in buildings
commonly ‘regulated’ approach. The work most widely applied has been that conducted by BRE.
7.7.1 UK BRE environmental profiles methodology The Environmental Profiles methodology is an LCA approach, i.e. a PCR developed for applying LCA to built environment scenarios. The methodology is designed and scoped to provide a ‘level playing field’ approach for all construction materials, i.e. an approach which is not biased to any particular type of material. The Environmental Profiles methodology allows direct comparison of the environmental impacts of functionally equivalent products, building specifications and buildings or even infrastructure. BRE developed the first edition of the Environmental Profiles methodology and its associated database in 1999 (Howard et al., 1999). A research programme through 2006–8 has culminated in its update, and the publication of a second edition of the Environmental Profiles methodology. The methodology provides the UK with an approach to the environmental life cycle assessment of all types of construction materials. It was developed with the UK material supply sector through close coordination with the Construction Products Association and its members. The Environmental Profiles methodology reports using the 13 environmental impact categories summarised in Table 7.2. It also applies a weightings step which enables a single score of environmental impact to be derived called the Ecopoint. The methodology has enabled BRE to develop three key LCAbased initiatives. These are now summarised.
7.7.2 Green guide to specification The Green Guide to Specification is now in its fourth edition. It is a specification aiding tool aimed at providing the building professional with easy-to-use guidance on how to make the best environmental choice when selecting construction materials and components. The fourth edition is available online and provides environmental ratings for more than 1200 specifications across various types of building. It is underpinned by the Environmental Profiles methodology and a LCI data collection exercise across a broad range of UK material suppliers. The environmental impacts for discrete specifications are presented as Ecopoint scores which have been converted into A+, A, B, C, D and E ratings. The online tool is expected to grow in functionality as BRE continue to develop it.
7.7.3 Envest This is a BRE commercial building software tool that combines LCA and whole life costing (WLC). It allows both environmental and financial © Woodhead Publishing Limited, 2010
Life cycle assessment and environmental profiling
189
tradeoffs to be considered in the design process. The user assigns their building design parameters (height, number of storeys, glazing area, etc.) and material specification choices (external wall, roof covering, etc.) into the tool. Envest then assesses the environmental impact (with LCA) and cost (with WLC) of the design. The tool reports on environmental impact using the Environmental Profile impact categories and Ecopoints, and costs in pounds sterling.
7.7.4 The environmental profiles certification scheme This is a Type III EPD certification scheme managed by BRE Global (the certification company of the BRE group). The scheme uses the Environmental Profiles methodology to produce EPD of manufacturer specific construction products and publishes Type III EDP declarations on behalf of the manufacturer. Each EPD is based on verified LCI for the manufactured product which has been audited by a certification officer through visiting the manufacture facility and reviewing production documentation. EPD are then listed in the GreenBookLive and also used to generate Green Guide to Specification ratings.
7.8
Other issues
The sustainability of a material or product is more than how it performs in a life cycle assessment. This section looks at three additional aspects and how they contribute to considering the sustainability of a material.
7.8.1 Healthy and safe materials Materials and their constituent components can contribute to a range of human health problems including carcinogenicity, endocrine disruption, and skin and mucous membrane irritation and sensitisation (to name but a few). From a safety perspective, material specification can have implications towards personal injury, accident, trauma or loss for stakeholders. Both health and safety aspects need to be considered throughout the building life cycle including extraction of basic material ingredients, the manufacture of these into a product, installation/construction, the maintenance requirement it demands in service and the implications for deconstruction and disposal at end-of-life. Therefore different materials and the way a design uses them will exhibit different health or safety levels. Generally government legislation exists to govern material impacts across these. However, this topic is important because many materials originate in places where human health and safety are not well regulated, or where the legislative frameworks might be considered
© Woodhead Publishing Limited, 2010
190
Materials for energy efficiency and thermal comfort in buildings
too tolerant. Beyond legislation, various frameworks for considering these issues exist and are formalising.
7.8.2 Resource management Resource management recognises that within a finite global system, there are limits to be respected by human activities. These will vary significantly from material to material, but resource management indicators can be used to determine performance including: ∑ ∑ ∑ ∑ ∑ ∑
abiotic depletion: depletion of non-renewable material resources renewability (or even rapidly renewable) recycled content recyclability efficient design and dematerialisation waste management practice.
Different strategies exist for driving good resource management and efficiency. The most common is that presented within the waste hierarchy of prevention, minimisation, reuse, recycling, energy recovery and disposal. LCA has the capacity to include a range of resource management based indicators and generally the issue should be considered in life cycle terms. On a practical level in the UK construction Site Waste Management Plans offer a mechanism to reduce waste arising on site and dispose of it efficiently when it arises.
7.8.3 Responsible sourcing Responsible sourcing is an approach of supply chain management, responsible manufacture and product stewardship, and encompasses social, economic and environmental dimensions. The concept is broad and many different variations of the concept exist. Within the construction products sector, the aspect is most mature within the timber industry with sustainable timber supply schemes like the Forest Stewardship Council (FSC) and the Programme for the Endorsement of Forest Certification schemes (PEFC) leading the way. The reality, however, is that responsible sourcing should be an objective of all material supply sectors. A company demonstrating good responsible sourcing practices is likely to be contributing to all the materials sustainability issues outlined in this chapter including addressing embodied impact, working to good heath and safety standards and ensuring good resource management practice. Sector schemes to drive corporate social responsibility of manufacturing practice, exercise good supply chain management, and product stewardship,
© Woodhead Publishing Limited, 2010
Life cycle assessment and environmental profiling
191
are starting to evolve. These commonly require that manufacturers address the following objectives: ∑ quality ∑ health and safety ∑ supply chain management ∑ environmental management ∑ specific environmental and social impacts of their operations.
7.9
References
Aizlewood C, Edwards S, Hamilton L, Shiers D, Steele K (2007), Environmental weightings: their use in the environmental assessment of construction products. Information Paper IP 4/07, Bracknell, IHS BRE Press. Boustead I (1996), LCA – how it came about. The beginning in the UK. International Journal of LCA, 1(3), 147–150. BS EN ISO 14020 (2002), Environmental labels and declarations – general principles. Geneva, International Standards Organisation. BS EN ISO 14021 (2001), Environmental labels and declarations – self-declared environmental claims (Type II environmental labelling). Geneva, International Standards Organisation. BS EN ISO 14024 (2001), Environmental labels and declarations – Type I environmental labelling – principles and procedures. Geneva, International Standards Organisation. BS EN ISO 14025 (2006), Environmental labels and declarations – Type III environmental declarations – principles and procedures. Geneva, International Standards Organisation. BS EN ISO 14040 (2006), Environmental management – life cycle assessment – principles and framework. Geneva, International Standards Organisation. BS EN ISO 14044 (2006), Environmental management – life cycle assessment – requirements and guidelines. Geneva, International Standards Organisation. BS EN ISO 15686-1 (2000), Buildings and constructed assets – service life planning – Part 1: General principles. Geneva, International Standards Organisation. BS EN ISO 21930 (2007), Sustainability in building construction – environmental declaration of building products. Geneva, International Standards Organisation. BS ISO 15392 (2008), Sustainability in building construction – general principles. Geneva, International Standards Organisation. BS ISO 15686-8 (2008), Buildings and constructed assets – service-life planning Part 8: Reference service life and service-life estimation. Geneva, International Standards Organisation. BS ISO/TS 21931-1, Sustainability in building construction – framework for methods of assessment for environmental performance of construction works – Part 1: Buildings. Geneva, International Standards Organisation. BS ISO 21932, Buildings and constructed assets – sustainability in building construction – terminology. Geneva, International Standards Organisation. Hamilton L, Edwards S, Aizlewood C, Shiers D, Thistlethwaite P, Steele K (2007), Creating environmental weightings for construction products: Results of a study, BR 493. Bracknell, IHS BRE Press.
© Woodhead Publishing Limited, 2010
192
Materials for energy efficiency and thermal comfort in buildings
Howard N, Edwards S, Anderson J (1999), BRE Methodology for Environmental Profiles of construction materials, components and buildings, BR370. Bracknell, IHS BRE Press. Hunt R G, Franklin W E (1996), LCA – how it came about – personal reflections on the origin and development of LCA in the USA. International Journal of LCA, 1(1), 1–4. ISO/TS 21929-1, Sustainability in building construction – sustainability indicators – Part 1: Framework for development of indicators for buildings. Geneva, International Standards Organisation. Parkin S (2000), Sustainable development: the concept and practical challenge. Proceedings of ICE, Civil Engineering, 138, November, 3–8.
© Woodhead Publishing Limited, 2010
8
Inorganic mineral materials for insulation in buildings R. G e l l e r t, FIW München, Germany
Abstract: Insulating products made from natural and/or synthetic mineral raw materials dominate the insulation market in Europe. Owing to their overall cost/performance ratio or their special product properties, mineral wool products for building insulation have gained the largest market share. Products such as mineral wool, cellular glass and expanded perlite are specified by harmonized European standards, while the niche-type products have either a manufacturer-specific European or national technical approval to prove to the consumer the fulfilment of regulatory requirements for the particular application. Key words: mineral wool, cellular glass, foamed glass, calcium silicate foam, ceramic fibres, aerogel, vacuum insulation, expanded perlite, exfoliated vermiculite, expanded clay.
8.1
Introduction
Thermal insulation is used to keep buildings cooler in summer and warmer in winter by reducing the flow of heat through the exterior surfaces of the building. The choice of insulation products will be guided by the application for which it is to be used, and the amount of insulation required will depend on the climate of the location, latitude and altitude at which the building is constructed. Buildings are responsible for 40% of Europe’s energy use and the largest share of energy in buildings is heating [1]. It is thought that up to 50% of buildings in Europe are uninsulated; however, thermal insulation can reduce the heat lost from buildings and therefore save energy and money. European legislation is driving increased installation of insulation through harmonization of building standards up to the levels of the most ambitious Member States. The European Energy Performance of Buildings Directive (EPBD) [1] was adopted in 2002 and is concerned with promoting energy efficiency in buildings across Europe using cost effective measures, whilst at the same time harmonizing standards across Europe to those of the more ambitious Member States. The EPB Directive centres around four key strands: This chapter is dedicated to Dr Walter F. Cammerer on the occasion of his 90th birthday.
193 © Woodhead Publishing Limited, 2010
194
Materials for energy efficiency and thermal comfort in buildings
∑
providing a methodology for calculating the energy performance of buildings, taking into account local climatic conditions; ∑ applying energy performance standards to both new build and existing building stock; ∑ providing a certification scheme for all buildings; ∑ regular assessments of any heating and cooling equipment installed.
These components had to be ratified by Member States by 4 January 2006, but most opted to defer this for three years. Unimpressed by the progress of Member States, the EU launched a public consultation on the recasting of the EPBD in 2008. This recast seeks to, amongst other things, broaden the scope of the EPBD by scrapping the 1000 m2 useful floor space threshold for buildings requiring to meet minimum energy efficiency standards; requiring Member States to apply ‘effective, proportionate and dissuasive’ penalties for non-compliance; and stipulating that Member States must draw up national roadmaps by 2011 for the development of low and zero carbon buildings. This legislation has a significant impact on the levels of insulation required in buildings and is likely to increase demand for insulation products in the future. As an example, in Germany an ‘Energy Savings Ordinance’ (‘EnEV’) is in effect. Amendments to the EnEV were enacted in the summer of 2008 and gave notice of the following major changes affecting building insulation (reference draft to EnEV 2009): ∑ tightening of energy requirements on building by an average of 30% ∑ extension of individual reconditioning obligations for equipment and buildings. Table 8.1 compares the highest values for the thermal transmission coefficient (Umax) stated in EnEV 2007 and the draft from 2009 for building envelopes on changes to building condition. The previously applicable version of EnEV specified the limit values to be observed for primary energy consumption of the building as a whole (envelope plus installations) and the specific transmission heat loss for the building (structural elements). Since the U-value (thermal transmission coefficient in W/(m2•K)) is included in the calculation of heat loss, it becomes Table 8.1 Highest thermal transmission coefficient values in accordance with the German EnEV for renovation of individual building components in existing buildings Building structural elements
EnEV 2007 EnEV 2009 (Umax W/(m2• K))
Tightening (%)
External walls (external insulation) External windows, French windows Slabs, roofs and inclined roofs Cellar slabs (cold-sided cladding)
0.35 1.70 0.30 0.40
31 24 20 25
0.24 1.30 0.24 0.30
© Woodhead Publishing Limited, 2010
Inorganic mineral materials for insulation in buildings
195
an important parameter for (un)insulated structural elements. The U-value is a measure for the transmission heat flow through a single or multi-layered material layer which separates two temperature areas (here: ‘external’ and ‘internal’). The inverse value of the thermal transmission coefficient is the thermal resistance, R (in (m2•K)/W). Both variables are important key figures for the characterisation of insulation effectiveness. The higher the R-value (in other words, the smaller the U-value), the better the material heat insulation properties. Insulation manufacturers will have to regulate their products to meet the (basic) requirements of the EnEV for thermal insulation in buildings. Thermal insulation materials are subject to heat transmission theories, as are all other building materials. Better heat insulation properties of insulation materials in comparison with other building materials result primarily from the trapped still air (or gases) inside the insulation material. The material of the insulator itself is mostly totally unsuitable or insufficient for thermal insulation on its own. For this reason the main aim in the development of heat insulation materials is to enclose a sufficient quantity of still air or other gases in small pores which are well distributed across the heat insulation material, in addition to using a base material which has as good heat insulation properties as possible. The heat transmission properties or thermal conductivity of insulation material is mainly affected by the following four variables: ∑
heat transmission of the insulation material framework (cellular framework or fibrous proportion) ∑ heat transmission of cell gases or gases in the interstices ∑ heat radiation in gas-filled interstices ∑ heat convection due to movement of gas particles. Good thermal insulation properties are achieved if an insulation material prevents heat transmission due to these four variables as much as possible. Insulation materials are categorized based on their internal structure in order to differentiate the influence of these variables on the insulation material. Since other physical boundary conditions are present in closed-cell insulation materials than in fibrous insulation materials or filled materials, one has to take this into account when judging the performance based on structural parameters of an insulating material. The thermal conductivity of the insulation material is almost independent both of the internal structure of the insulation material and of the material of the selected solid if the pores are small and well distributed. An increasing solid material proportion, accompanied by an increasing bulk density, results in an increase of the material thermal conductivity; a lower solid material proportion reduces the proportion of thermal conductivity attributable to the material framework for the overall thermal conductivity but does, however,
© Woodhead Publishing Limited, 2010
196
Materials for energy efficiency and thermal comfort in buildings
increase the thermal transmission due to radiation due to the increasing proportion of pores [2]. the ‘resulting’ material characteristic value for insulation materials is the thermal conductivity l (in W/m•K). this is linked to the thermal resistance R by the layer thickness d: R = d (in (m m 2 •K K)/W)) l Insulating materials can be separated into organic and inorganic groups based on their raw materials. Furthermore, each group is separated into natural and synthetic materials. Depending on the structure, the results are fibrous materials, foams or granulates. The organic natural raw materials group offers the widest range of products. the european market is split into these two main product categories according to the chemical and physical structure of the insulation materials: inorganic mineral materials and organic materials (see table 8.2). For instance, in 1999 building thermal insulation accounted for 65% of the total UK thermal insulation market, compared with 62% in 1995 and this was expected to increase by 8% between 2000 and 2004. the largest share of the market (52%) was represented by wall insulation products, 41% of which consisted of cavity wall insulation. loft insulation had the second largest share, accounting for 25% of the market in 1999. According to a recent study, inorganic fibrous materials will experience a 5% growth in the next decade. It should be noted that these figures are for the UK only and therefore cannot be taken as representative of other eU countries, but indicate their magnitude. the situation in Germany is illustrated in Table 8.3. Table 8.2 Mineral materials employed for the manufacture of insulating materials and products for building applications Inorganic insulating materials Synthetic
Natural
Mineral wool: ∑ glass wool ∑ rock wool Cellular glass Foamed glass Calcium silicate foam Ceramic fibres Aerogel Pyrogenic silicic acid/ (Vacuum insulation panels) Slag wool Gypsum foam
Expanded perlite Exfoliated vermiculite/expanded mica Expanded clay Pumice Insulating clay bricks
© Woodhead Publishing Limited, 2010
Inorganic mineral materials for insulation in buildings
197
Table 8.3 Market share of insulating materials and products in Germany [3] Product/Year Market share (%) ———————————————————— MF Organic insulating Others materials
Total Market (Mio. m3)
1989 1994 1999 2000 2003 2004 2005
16 28 34 34 27 27 24
59 60 58 58 58 55 56
40 39 36 37 38 39 40
MF = Organic insulating materials = Others =
8.2
1 1 6 5 4 6 4
mineral fibre products expanded polystyrene (EPS), extruded polystyrene foam (XPS), polyurethane foam (PUR/PIR) including products from natural organic and inorganic raw materials
Regulatory requirements
Complementing the EPBD, the European Construction Products Directive (CPD) is aimed at creating a single market for construction products through the use of ‘CE marking’. It outlines key requirements relating to materials intended for construction, which is defined in the Directive as products that are manufactured to form a permanent part of structures. The materials must meet fundamental requirements including mechanical resistance and stability, safety in case of fire, hygiene, health and the evironment, safety in use, protection against noise and energy economy and heat retention. The Directive mandates that standardization organizations such as CEN develop standards in consultation with industry. A list of these standards can be found on the European Commission’s website. Where harmonized standards are not available, existing national standards may still be used. Since insulation materials are usually regulated building products, their properties (specifications) are described in technical codes of practice (standards, building authority certification). Now that the building products law based on the European building product guidelines has been passed, harmonized European standards have been produced, or are in the process of being drawn up, for standard market insulation materials. Their transfer into the national regulations means that they are now given a national EN designation. A different procedure applies to the European technical approvals (ETAs) for insulation materials which have not yet been standardized, but ETAs also have to be accepted nationally. The harmonized product standards (hEN) are supported by cross-sectional
© Woodhead Publishing Limited, 2010
198
Materials for energy efficiency and thermal comfort in buildings
standards such as testing methods, calculations or safeguarding of standard observance. The harmonized specification standards enable insulation material manufacturers to provide a mostly open description of their products using standard features; these are mostly expressed in classes, levels or nominal values (e.g. for thermal conductivity). If the manufacturer declares conformity with the appropriate standard he can give his products the CE conformity marking and place it on the market. An additional voluntary product certification is based on codes of practice which determine the process by which the conformity verification has been produced in the context of the certification programme. This enables manufacturers to receive a protected marking in accordance with the rules of a certification programme by specific authorized organizations (e.g. quality protection organizations, associations or testing laboratories). Voluntary product certification has a long tradition in many Member States. For insulation materials, such markings are often issued in combination with the Institute supervision previously required by the building authorities and an agreement verification process. The following information about an insulation material is provided on the label or in the manufacturer’s declaration – the first five being compulsory, others depending on the individual product specification standard: ∑ ∑ ∑ ∑ ∑ ∑
thermal conductivity/thermal transmission resistance dimensions and tolerances mechanical characteristics behaviour in water (vapour) fire behaviour (Euro class) soundproofing characteristics, e.g. dynamic stiffness or length-related air flow restistance
Table 8.4 lists the existing standards, preliminary standards or approvals for the insulating materials and products described in this chapter. As the standards for the factory made products were written according to a ‘model standard’ and published as a ‘package’, the three standards listed in Table 8.4 all have an identical structure. In the ‘heart of the standard’ one will find the requirements, the test methods, the designation code, the rules for the attestation of conformity and the rules for marking and labelling. For insulation products which are produced on-site, the relevant standards – still in the preliminary stage – are written in two parts: ∑ ∑
one part addressing the (basic) raw material the second part describing the ‘conversion’ from a loose-fill material into a thermal performance product on site.
Based on properties to be declared for all applications and also – if declared
© Woodhead Publishing Limited, 2010
Table 8.4 European technical specification standardsa and approvalsb for insulating materials based on mineral materials [4], [5], [6] Abbreviation
Technical specification Factory made
In-situ application
Building equipment
© Woodhead Publishing Limited, 2010
1 Mineral wool MW EN 13162: 2008 pr EN 14064-1 pr EN 14303 EN 13500: 2003c pr EN 14064-2 2 Cellular glass CG EN 13167: 2008 pr EN 14305 3 Foamed glass National technical approval 4 Calcium silicate foam CS ETA pr EN 14306 (and similar mineral foams) (ETAs) 5 Ceramic fibres, foams Industrial application mainly 6 Aerogel National technical approval 7 Vacuum insulation panel VIPd National technical approval 8 Expanded perlite EP EN 13169: 2008 EN 14316-1: 2004 pr EN 15501 (EPB = boards) EN 14316-2: 2007 9 Exfoliated vermiculite EV EN 14317-1: 2004 pr EN 15501 EN 14317-2: 2007 10 Expanded clay EN 14063-1: 2004 pr EN 14063-2 a
Published standards and standards under development are listed by CEN (www.cen.en/CENORM); EOTA provides details on technical approvals (www.eota.be); c EN 13500 specifies MW-products for the external thermal insulation composite system application; d VIP with pyrogenic silicic acid as core material. b
Inorganic mineral materials for insulation in buildings
No. Product
199
200
Materials for energy efficiency and thermal comfort in buildings
by the manufacturer – for a specific application one can summarize important standardized performance criteria as in Table 8.5. Table 8.5 Standardized properties, relevant test methods and designations Property
Test method
Symbol
Thermal resistance EN 12667 or RD EN 12939 lD Length and width EN 822 l and b Thickness EN 823 d Squareness EN 824 Flatness EN 825 Dimensional stability EN 1603 De under normal laboratory conditions Bending strength EN 12089 sB Reaction to fire EN 13501-1 Apparent density EN 1602 ra Dimensional stability EN 1604 De under specified temperature Dimensional stability EN 1604 De under specified temperature and humidity conditions Deformation under EN 1605 e compressive load Compressive stress at EN 826 s10 10% deformation Tensile strength EN 1607 smt perpendicular to the faces Tensile strength EN 1608 st parallel to faces Point load EN 12430 Compressive creep EN 1606 ect Shear strength EN 12090 t Water absorption, EN 1609 short term Water absorption, EN 12087 Wlp long term Water vapour EN 12086 m transmission/resistance factor Dynamic stiffness EN 29052-1 s’ Thickness EN 12431 dL Thickness dB Compressibility c Sound absorption EN ISO ap 354:1993/A1 aw Air flow resistance EN 29053 Organic content EN 13820
Dimension 2
m •K/W W/(m•K) mm mm mm/m mm %
Designation R, l L and W T S P or Smax DS (N)
kPa BS (Euroclasses) A, B, C, D, E, F kg/m3 % DS(T)
%
DS(T, H)
%
DLT
kPa
CS(10)
kPa
TR
kPa N % kPa kg/m2
PL(P) CC( )sc
kg/m2
WL(P)
m2 • h• Pa/mg
Z or MU
MN/m3 mm mm —
SD
kPa•s/m3 %
AF Moc
© Woodhead Publishing Limited, 2010
WS
CP AP/AW
Inorganic mineral materials for insulation in buildings
8.3
201
Building-related properties
Since differentiation must be made between European and national applications under the harmonized codes of practices in the philosophy anchored in the building products guidelines, the client, planner or architect must take note of the requirements contained in the (national) list of technical building regulations for thermal insulation (sound and fire protection as well, if necessary). In this case the technical regulations of interest for thermal insulation are contained (in Germany) in DIN V 4108: (application-based requirements on insulation materials). ∑ ∑
Part 4:2004-07 Thermal insulation and energy economy in buildings – Part 4: Hygrothermal design values. Part 10:2004-09 Thermal insulation and enrgy economy in buildings – application-related requirements for thermal insulation materials – Part 10: Factory made products.
Examples of the most common applications of thermal insulation products in buildings, excluding building equipment are given in Table 8.6. Because of its importance as the most important building-related property, in the European system for handling the thermal conductivity lD (or the thermal resistance RD respectively) of insulation products, one has to follow an elaborate (statistical) scheme, which includes the following details: ∑ The declared thermal conductivity lD is determined on the basis of statistically evaluated measurements (l90/90) – to be organized by the manufacturer. Details are given in the respective product standard (in the normative Annex A); lD is declared in steps of 0.001 W/(m•K). ∑ Design values for the particular building application are defined nationally – due to different building codes and/or the climate in question. An overview of the basic building-related properties is given in Table 8.7, some specific properties of interest here in Table 8.8. Besides the ‘core properties’ which determine the performance of an insulating material, some products have good acoustic or specific fire performance characteristics that the manufacturer wishes to declare – or has to declare for a certain application – already when placed on the market, i.e. the reaction to fire classification. The latter has now been based on the European (classification) standard EN 13501-1 and the following Euroclasses with respect to the combustibility of building materials (reaction to fire) have been agreed upon: ∑ A1 + A2 No contribution to a fire/non-combustible ∑ B Very limited contribution to a fire ∑ heat propagation ∑ flame propagation
© Woodhead Publishing Limited, 2010
202
Materials for energy efficiency and thermal comfort in buildings
Table 8.6 Examples of the most common applications of thermal insulation products in buildings – excluding building equipment [7] Application Roof Pitched Unloaded insulation between rafters, fully supported roof Insulation separating rafters and outer covering Insulation separating supporting construction and outer covering Insulation beneath rafters Flat roof
Insulation between rafters or beams Inverted, insulation above roofing membrane including roof gardens and parking decks On steel deck, insulation beneath roofing membrane Accessible to light or heavy traffic or loads from roof garden (soil layer, plants, etc.) and parking decks (concrete pavers or slabs), insulation beneath roofing membrane Accessible only to maintenance personal, insulation beneath roofing membrane
Wall
Masonry or concrete wall, external insulation covered by rendering Timber stud construction, outside insulation and rendering directly supported by the studs Timber stud construction, insulation at the internal side with rendering Masonry or concrete wall, fully supported internal insulation supporting light protective internal facing (e.g. gypsum board) Masonry or concrete wall, internal insulation supporting light protecting facing, partly supported by studs Masonry or concrete wall, internal insulation with heavy selfsupported protective internal facing (e.g. tiles at roomside) Timber or metal stud construction with boards covering, insulation between the studs Cavity wall construction, insulation between the leaves, cavity ventilated Cavity wall construction, cavity fully filled with insulation, outer leaf not watertight Timber or metal stud construction with boards covering, insulation supported by boards: or masonry or concrete wall, supporting the insulation with ventilated exterior covering Wall under ground, external insulation behind waterproof membrane with mechanical protection Wall under ground, external insulation with direct contact to the ground Cellar or crawlspace hall, internal insulation with or without covering
Ceiling/floor Insulation over the supporting construction or between the beams Insulation under load distributing flooring, fully supported Insulation under the construction Foundation
Concrete, insulation under the slab with direct contact to the ground Concrete, insulation supported by the slab, above waterproof membrane, beneath load distributing flooring Concrete, insulation under the slab above waterproof membrane Frost insulation in or against the ground
© Woodhead Publishing Limited, 2010
Inorganic mineral materials for insulation in buildings
203
Table 8.7 Typical building application related properties (where given) [8–10] Material
Property
Thermal Density conductivity l D1 p (mW/(m • K)) (kg/m3)
Specific heat capacity c (J/(kg • K))
Mineral wool 32–50 10–400 600–1000 Cellular glass 38–60 100–220 800–1100 Foamed glass 70–92 150–300 800–1000 Calcium silicate foam 45–65 115–390 1000 Ceramic fibres, -foam 30–70 100–240 1040 Aerogel 15–21 30–100 700–1150 150–300 n.a. VIP (SiO2 as core material) 4–8 (Pyrogenic silicic acid) (18–21) (300) (1000) Expanded perlite (board) 40–70 90–400 1000 Exfoliated vermiculite 60–70 60–180 800–1000 Expanded clay 85–160 260–500 1000 Insulating clay bricks 70–140 500–750 1000
Water vapour diffusion resistance index m 1–4 Water vapour impermeable 1–5 3–20 n.a. n.a. Water vapour impermeable 3–5 3–4 2–8 5–10
1. Declared thermal conductivity by the manufacturer. Table 8.8 Selected specific properties based on manufacturers’ declarations (where appropriate and given) [8] Material/Product
Specific property
Compressive strength (kPa)
Tensile strength perpendicular to faces (kPa)
Maximum service temperature short-term long-term (°C)
(°C)
Mineral wool: with binder 3.5–80 250 100–200 Glass wool: without binder 600 500 Rock wool: without binder 1000 600–750 Cellular glass 500–1700 700 430 Foamed glass 120–140 600–700 Calcium silicate foam 350–> 1000 1050–1100 Ceramic fibres, -foam > 1000 1100–1430 Aerogel Pyrogenic silicic acid* Expanded perlite board 150–300 > 40 250 800 Exfoliated vermiculite 100–450 n.a. 700–1100 Expanded clay ViP 45–120 *Core material of vacuum insulation panels (VIP)
© Woodhead Publishing Limited, 2010
204
∑ C ∑ D ∑ E ∑ F
Materials for energy efficiency and thermal comfort in buildings ∑
smoke propagation Limited – but some – contribution to a fire Not negligible contribution to a fire Poor fire reaction properties ∑ acceptable ignitability ∑ limited flame propagation No performance determined – no data available
Table 8.9 summarizes those properties. There are six main applications for mineral insulation products in the building sector (general definitions are given here, details with respect to individual products are listed in Table 8.10): 1. Cavity wall. A cavity wall is defined as an external wall made of two layers with a small air gap or ‘cavity’ between them. By filling the gap between the two walls with an insulating material, the amount of heat escaping through the walls can be reduced. 2. Solid wall. A solid wall is defined as an external wall without a cavity. Solid walls lose more heat than cavity walls of the same material. However, insulation can be applied to the inside and/or the outside of the wall to reduce heat loss. Insulation boards are typically used for these purposes. Solid walls also cover stone walls which have a random
Table 8.9 Properties related to acoustic and fire performance (manufacturers’ declarations – where given) [8] Material/Product
Acoustics
Dynamic stiffness s¢ (MN/m3)
Reaction to fire Euroclasses Sound impedance acc. to per unit length EN 13501-1 r 2 (kPas/m )
Mineral wool – glass wool – rock wool 7–35 6–43 Cellular glass Foamed glass Calcium silicate foam (mineral foam) Ceramic fibres, -foam Aerogel Pyrogenic silicic acid Expanded perlite board Exfoliated vermiculite Expanded clay VIP (SiO2 as core material)
© Woodhead Publishing Limited, 2010
A1, A2 A1 A1 (non combustible) A1 (A2) (non-combustble) A1 (non-combustible) A2-s1,d0; B-s1,d0, C-s1,d0; D-s1,d0 A1 (non-combustible) E
Inorganic mineral materials for insulation in buildings
205
Table 8.10 Application matrix (based on the German DIN 4108–10 and ISO TR 9774) [7], [10]
∑
∑
∑
∑
∑
∑
External insulation of upper floors or roofs, protected from the weather, insulation below roof covering
∑
∑
External insulation of upper floors or roofs, protected from the weather, insulation below waterproofing
∑
∑
External insulation of roofs, exposed to the weather (inverted roof)
Insulation between rafters, double-skin roofs, accessible but non-trafficked topmost floor
∑
Internal insulation of upper floors (underside) or roofs, insulation below rafters/ structure, suspended ceiling, etc.
∑
∑
Internal insulation of upper or ground floors (top side) below screed, without sound insulation requirements
∑
∑
Internal insulation of upper or ground floors (top side) below screed, with sound insulation requirements
∑
Wall
External insulation of walls, ∑ behind cladding External insulation of walls, behind waterproofing
∑
External insulation of walls, behind render
∑
∑
Cavity insulation of double- leaf walls
∑
∑
∑
∑
∑
∑
∑
∑
∑
© Woodhead Publishing Limited, 2010
∑
∑
∑
∑
Expanded clay
Expanded perlite board
Floor and roof
Exfoliated vermiculite
VIP
∑
Ceramic fibres, – foam
∑
Calcium silicate foam
Foamed glass
Cellular glass
Aerogel
Products from mineral raw materials
Mineral wool
Application
206
Materials for energy efficiency and thermal comfort in buildings
Table 8.10 Continued
Insulation to timber-frame and timber-panel constructions
∑
Internal insulation of walls
∑
Insulation between partition walls with sound insulation requirements
∑
Insulation to separating walls
∑
Basement
External thermal insulation of walls in contact with soil (on outside of waterproofing)
∑
External thermal insulation below ground floor slab in contact with soil (below waterproofing)
∑
∑
∑
∑
∑
∑
Expanded clay
Expanded perlite board
∑
Exfoliated vermiculite
VIP
∑
Aerogel
∑
Ceramic fibres, – foam
∑
Calcium silicate foam
Foamed glass
Cellular glass
Products from mineral raw materials
Mineral wool
Application
∑ with standardized properties with building authority approval for the product for this application rarely used as thermal insulating material
arrangement of cut or more usually irregular broken stone blocks bonded with a cementious mortar. 3. Loft (attic) insulation. Loft insulation is defined as material applied to the floor of the loft, between and over joists. This is most often loosefill insulation, which is blown onto the loft floor or batts and rolls of insulation are used. 4. Floor insulation. Floor insulation is defined as material that is installed between the beams or joists under a raised floor or, in the case of concrete floors, insulation board installed under floor finishes, such as carpet or under a floating floor. 5. Roof insulation. Here insulation is placed on the underside of the roof instead of on the loft floor. Spray foam (rarely) or insulating boards are most often used for this purpose. Roof insulation between rafters is a major application area for, e.g., mineral wool.
© Woodhead Publishing Limited, 2010
Inorganic mineral materials for insulation in buildings
207
6. Insulation of pipework and ducts as part of building equipment. To preserve the temperature of water and air flowing through pipework and ducts, thermal insulation is used. Insulation of pipework and ducts is defined as lagging or insulation used around pipes or ducts. Products for this purpose are often moulded to the shape of the pipes. Other types of insulation include prefabricated structural wall and roof panels, e.g. sandwich panels, stressed skin panels, and steel frame systems. The properties outlined above in the various tables – in short the performance characteristics – have led the products made from mineral materials to be used in certain applications which can best be visualized in a matrix (Table 8.10). Based on the European technical harmonization, the EU Member States are responsible for developing rules for the specific use of insulating materials in construction works, e.g. in roofs or walls – as outlined in Table 8.10 for Germany as an example.
8.4
Ecological and health aspects
Since industrialization the energy intensity of the production of building materials has increased due to the shift from locally produced raw materials and human energy to high temperature manufacturing processes that consume large amounts of fuel energy and use components and materials that have been transported across the world. This increase in the pre-use energy consumption of materials is accompanied, however, by the advent of insulating materials that can significantly reduce the operational energy use of a building. There is general agreement across the construction industry that installing insulation materials in new and existing buildings is one of the best ways to reduce the environmental impact of buildings. In this respect, any insulation material can be deemed preferable to no insulation. There is a range of insulating materials each with their own benefits in terms of environmental performance. The life cycle of a thermal insulation product consists of a number of key phases, which are summarized as follows: ∑
∑
Extraction and processing of raw materials. Mining operations and refining ores for the manufacturing process will result in environmental issues and impacts; these include high energy use, physical disturbance of the landscape and pollution from toxic emissions, which may affect land, water and air. There is scope to use recycled content within many insulation products, which would reduce the impacts at this stage. Insulation manufacture. The manufacturing processes for the different categories of insulation vary; however, all have significant environmental
© Woodhead Publishing Limited, 2010
208
∑
∑
∑
∑
∑
Materials for energy efficiency and thermal comfort in buildings
impacts, including energy consumption, the use of materials with hazardous properties and the production of hazardous wastes. Packaging. The insulation is cut to size and wrapped in packaging to allow transportation. This packaging has environmental implications through its manufacture and, if oil-based polymers are used, it could result in additional non-biodegradable waste if not reused or recycled properly. Transport to retail unit. The main environmental impact is energy consumption (fuel use) and associated air quality and emissions by the vehicles. It should be noted that insulation products that require smaller volumes of material and/or are lighter (lower density) to achieve the desired level of thermal resistance might have lower transport emissions. This is due to fewer vehicles being required and/or less energy to transport the material. Installation. Transportation from the retail unit to the building where the insulation is to be used has an impact through fuel use and vehicle emissions. The efficiency of the installation also affects the degree of wastage and the efficiency of the insulation (gaps in the insulation can reduce its effectiveness). Also, heavier insulation products may require additional equipment and fixtures to secure them in place compared to lighter (less dense) alternatives. Use and maintenance. There is very little in-use impact. However, the maintenance of insulation materials can affect their effectiveness. For example, dampness and compression can reduce the effectiveness of some insulation products as the presence of water or reduced thickness through compaction will increase the amount of heat transferred through the material in comparison to properly dry air-filled insulation. Insulation products with closed cell structures and high compressive strengths are less vulnerable to these factors. End-of-life. Reducing further environmental impact will depend on the management and handling of insulation products at the end of their useful life; mismanagement can result in increased impacts on the environment, for example hazardous waste being disposed of to landfill or the emission of toxic particulates into the atmosphere. Disposal options for insulation depend on the type of material used: some will have to be disposed of as hazardous waste.
For each of the phases listed there will be an element of energy input. There will also be emissions to air, land and water and some degree of waste, which will either be suitable for reuse or recycling or have to be sent for disposal. The so-called ‘eco-balance’ takes into consideration all stages of the life cycle, i.e. acquisition, production, use and end-of-life plus transportation for combining the different stages. For a specific use-phase Table 8.11 gives a comparison of the most important ecological parameters. © Woodhead Publishing Limited, 2010
© Woodhead Publishing Limited, 2010
Material/Product
Ecological parameter a
b
Material property c
Calorific value PE-Input GWP APd (MJ/kg) (MJ/m3) (kg CO2-eq./m2) (kg SO2-eq./kg)
Density Thickness ~ (kg/m3) (m)
Mineral wool: – glass wool 0.0 102 5.335 0.04 23 0.11 – rock wool 0.0 400 27.979 0.19 160 0.13 Cellular glass 0.0 467 16.873 0.104 115 0.13 Calcium 0.0 6400 504.1 0.69 200 0.19 silicate foam (non-renewable) 260 (renewable) a
Calorific value: Can be gained in a later combustion process. PE-Input: Primary energy input covering all energy used to manufacture the product. c GWP: Global warming potential. d AP: Acidification potential. b
Lambda lD (W/(m•K)) 0.035 0.040 0.040 0.060
Inorganic mineral materials for insulation in buildings
Table 8.11 Ecological performance based on standardized conditions (U-value = 0.3 W/(m2•K); PE-investment = 0.22 W/(m2•K)) [3]
209
210
Materials for energy efficiency and thermal comfort in buildings
Provided that in the near future data and parameters for all insulation materials are generated on a standardized basis, the end-user can choose their product both on the technical and the ecological performance checklist. However, one should keep in mind that no matter which approved insulating product is chosen, the ‘return-on-energy investment’ is – depending on the climate – usually only one heating period. Under Mandate 350 of the EU Commission the relevant CEN working group aims to establish a methodology for calculating the use of non-renewable energy (measured in mega joules) for different stages of the product life cycle. The Mandate will lay down the methodology to allow manufacturers to calculate these values and list the use of non-renewable energy and many other environmental/sustainability values in an environmental product declaration (EPD). The EPD will allow contracting authorities to benchmark products based on a comparison of the information included in the EPD. So far those product characteristics that have been described reflect the more technical performance, i.e. mechanical strength, fire protection, sound insulation and, of course, thermal insulation. The ‘Essential Requirement 3 (ER 3)’ of the European CPD demands that construction works should not endanger users through any of the following: ∑ ∑ ∑ ∑ ∑ ∑
the giving-off of toxic gas the presence of dangerous particles or gases in the air the emission of dangerous radiation the pollution or poisoning of the water or soil the faulty elimination of wastewater, smoke, solid or liquid wastes the presence of damp in parts of the works or on surfaces within the works.
When suitable quality control and professional installation has been applied, it is normally possible to say that there are no health or usage influences through the use of thermal insulation materials. It is, however, necessary to state at this point that there is a possibility of general odour annoyance, formaldehyde gas emissions, (natural) radioactive radiation, dust loading and the danger of pesticide residues. The reusability of an insulation material is mainly dependent on whether it can be dismantled homogeneously and true-to-type. Often this is possible with relatively few problems for filled materials or insulation layers which are only fixed mechanically; the reuse of glued or rendered products is almost impossible. If use of soiled insulation material residues is not possible as an additive mixture or for soil loosening, the material has to be taken to a land-fill or used energetically (as far as is possible and feasible) as an incineration material. Now that national and European politics is becoming more environmentally aware, consideration of the potential harm to health of insulation materials with
© Woodhead Publishing Limited, 2010
Inorganic mineral materials for insulation in buildings
211
regard to manufacture, use and disposal is becoming more and more the centre of focus in standardization activities.
8.5
Individual product profiles
As listed in Table 8.2, there are various natural and synthetic (raw) materials employed in the manufacture of mineral insulation products. While most of the products listed play a more or less significant role in terms of market share for thermal building applications, two of the products mentioned, namely slag wool and gypsum foam, are of no importance for the applications addressed in this chapter. Some information about these products can be found in reference [8]. This leaves ten product types that will be profiled in more detail in this section. Table 8.12 lists their usual forms of supply to the marketplace.
8.5.1 Mineral wool Glass wool (Fig. 8.1) is made from sand, limestone and soda ash with a high proportion of recycled glass, plus other minerals. These are melted, spun into fibres and mixed with organic resins before curing into products. The mineral raw materials are melted at approximately 1400 to 1500 °C. An aqueous binder is sprayed onto the fibres during the spinning process. The fibres cool down fast and stiffen glassily. The binder is then hardened in a tunnel stove at roughly 250 °C through which the products get their structural stability. Afterwards they can be cut into boards, slabs or batts. The typical composition of glass wool is roughly 70% recycled glass, 0.5 to 7% binder (on a phenolic resin basis) and 0.5% mineral oil to avoid dusting. The other Table 8.12 Usual forms of supply of products made from mineral raw materials Material/Product
Forms of supply
Boards, batts Loose fill
Caulking materials
Mineral wool ∑ ∑ Cellular glass ∑ Foamed glass ∑ Calcium silicate foam ∑ Ceramic fibres, -foam ∑ Aerogel ∑ ∑ Vacuum insulation ∑ Expanded perlite ∑ ∑ Exfoliated vermiculite ∑ ∑ Expanded clay ∑
© Woodhead Publishing Limited, 2010
Sandwich ∑
∑ ∑
212
Materials for energy efficiency and thermal comfort in buildings
8.1 Glass wool MW (Source: FIW München).
components are derived from the usual glass manufacturing, i.e. quartz and limestone. Recently mineral wool products have been introduced to the market that contain additives (binders) on a renewable organic raw material basis, affecting the optical appearance and improving the ecological balance. Stone or rock wool (Fig. 8.2a) is based on natural minerals, e.g. volcanic rock, typically basalt, plus recycled post-production waste materials; the components are melted, spun into fibres and then mixed with a binder and an impregnation oil. There is a wide variety of products ranging from loose pelleted materials suitable for cavity wall insulation, to rolls and light boards for loft insulation and dense slabs used for light load bearing application in floors and roofs. Pre-formed pipe insulation and wired matting are used for industrial applications. Rock or stone wool thus usually contains 30% recycled raw material, i.e. waste glass, 0.5 to 7% binder (phenolic resin polymer) and 0.5% mineral oil, the larger portion composed of the natural raw materials mentioned above. ‘Hybrid products’ combining both raw material basis and technologies
© Woodhead Publishing Limited, 2010
Inorganic mineral materials for insulation in buildings
213
(a)
(b)
8.2 (a) Rock wool MW, (b) Composite board WW and MW (Source: FIW München).
are now offered to the market thus combining the high melting point of rock or stone wool with the elasticity of glass wool. Mineral wool stands out due to its universal material qualities for a wide range of applications. It offers protection from cold and warmth, absorbs sound and offers a good fire protection. In addition, lightweight mineral wool
© Woodhead Publishing Limited, 2010
214
Materials for energy efficiency and thermal comfort in buildings
shows good handling properties, is physically quite safe for the health and very resistant to ageing. Furthermore, mineral wool is a highly standardized insulation material. The conformity with standards is supervised by recognized independent institutes (‘notified bodies’) and the products usually carry an (additional) quality mark next to the CE marking, the latter being based on EN 13162. Because mineral wool can be delivered as a non-combustible insulation material, it offers an important contribution to the preventive structural fire protection. Depending on the implementation, it meets most building requirements for fire resistance. Mineral wool products are offered by manufacturers in a large variety of implementation options, e.g. with additional functions like protection against noise. A good insulation in connection with warmth storing mass in the inside area offers very good thermal protection in the summer. Since mineral wool can be processed with ease from the cellar up to the roof even by DIY enthusiasts in their own home; it has gained wide acceptance in the DIY market. The simple handling of mineral wool is further supported by a versatile choice of ‘system products’ for different problem solutions (Fig. 8.2b). The processing of mineral wool, e.g. at façades (ETICS) should, however, be carried out by professional craftsmen. As mentioned before, mineral wool products carry a quality mark and comply with certain (national) safety standards. Before the products are marked with a quality mark, the mineral wool manufacturer must undergo quality examinations with respect to the fibre composition and fibre dimensions. These proofs are provided by independent testing institutes. Even after awarding a mark, e.g. in Germany by RAL, the production of the manufacturers is under regular third party control. Mineral wool can in principle be recycled and utilized again. For example, (production) waste can be supplied again to the mineral wool production process and will be reutilised in new mineral wool. Mineral wool can be disposed of like any other building rubble. The regulations of single individual operators or regional specifications have yet to be taken into account if necessary. Returning to the health and safety aspect and taking Germany as an example, the so-called ‘chemical ban ordinance’ – more correctly ‘Ordinance for the Change of Chemical Legal Ordinances’ addresses, among other things, the fibre issue. Since June 2000 it states a ban on the circulation, production and use of bio-persistent artificial mineral fibres for heat protection and sound absorption in buildings, and for the technical insulation. At the same time, it includes an exemption regulation for non-bio-persistent, thus biologically soluble fibres which, if in compliance with the three ordinance certificate criteria, are exempted and consequently permitted by the ordinance. The three compliance exoneration certificate criteria are defined clearly; they are derived from the German Hazardous Substances Ordinance and are at
© Woodhead Publishing Limited, 2010
Inorganic mineral materials for insulation in buildings
215
the same time the criteria to be obeyed by mineral wool products with a quality mark. Mineral wool products awarded with such a quality mark are not subject to the prohibition of the chemical ban ordinance. For particular applications, the fibrous structure has been adapted to the specific application needs: in the external wall sector (ETICS), products have been optimized and these new developments provide the market with insulation panels with ‘dual-layer characteristics’: the normal lamellar layers provide the good insulation properties, the high compaction of lamellae on the outer side creates an extremely hard surface layer which makes the application of the reinforcing compound and the rendering easier. Another development, a thermal-bridge-free insulating layer can be applied with fabric rolls for cavity masonry (cavity wall insulation).
8.5.2 Cellular glass Cellular glass (CG) (Fig. 8.3) is an inorganic thermal insulating material with a closed cell structure. It is mainly made of glass (usually with a high proportion of recycled and waste glass added) plus calcium fluoride, sodium carbonate, iron oxide, manganese oxide, sodium sulfate and sodium nitrate melted at 1400 °C to form glass, then – using carbon as a blowing agent – baked in a high temperature tunnel furnace, annealed in a long tunnel where the temperature is slowly decreased and finally cut into boards or slabs. It well preserves the chemical stability of inorganic glass. As a result, CG has the following features: fairly low density, low thermal conductivity, water
8.3 Cellular glass CG (Source: FIW München).
© Woodhead Publishing Limited, 2010
216
Materials for energy efficiency and thermal comfort in buildings
and water vapour impermeability, no water absorption, incombustibility, protection from mould, high mechanical strength but easy to cut and able to bear all kinds of chemical erosions except hydrofluoric acid. Cellular glass, non-toxic in itself, has an excellent durability and a good thermal insulating performance over a wide temperature range (from cryogenic temperature to high temperature). At the same time, it can protect from humidity, fire and erosion. It is praised as ‘permanent thermal insulating material with no need of renewal’, because it is not only safe but also durable in extreme conditions of low and cryogenic temperature, underground, open air, flammability, moisture sensitivity and even chemical erosion. Consequently, it is widely applied in permanent projects as heat and cold insulating material in industry. For this application the manufacturers supply the industry with specially designed parts, e.g. in shapes of various diameters for pipe insulation. In building application the boards or slabs can be used as insulating material in floors, walls and roofs. Specially cut (‘tapered’) products can be used to construct insulated tapered roof systems. Owing to its brittleness the boards or slabs are usually completely coated in bitumen so they can be laid down evenly. Due to the higher price compared with other standard insulating materials, CG is typically found in applications with high compressive or moisture loads, e.g. roof top car parks or below-ground load-bearing uses. A special load-bearing application is the use of ‘cellular glass bricks’ at the base of single-leaf external walls, at the base of the inner leaf of double-leaf walls on suspended floors over outside air and over the basement. This will help to eliminate thermal bridges. Depending on the intended use, manufacturers also supply the market with a variety of faced cellular glass boards; the one, or two, facings may be roofing felt, metal foil or paper cardboard or plastic foil. The core of these composites may consist of either one board, a part of a board or a number of boards bounded edge-to-edge in the factory; bitumen may be a suitable adhesive which may be used to bond the joints and the facings. This in turn will, of course, affect the reaction-to-fire rating (Euroclassification).
8.5.3 Foamed glass Foamed glass (Fig. 8.4) is formed from a reaction between glass and carbon at high temperature resulting in CO2 being trapped in minute bubbles in the glass, giving a cellular structure. It contains no petrochemical binders or preservatives. It is blown with carbon dioxide and has sulphur added. The composition (by volume) of foamed glass is usually: 5% glass, 95% gas (comprising 99% CO2, 0.7% H2S, 0.3% N2). Also waste glass can be recycled into foamed glass yielding a product with excellent mechanical and decent insulation properties. The product is water vapour impermeable and
© Woodhead Publishing Limited, 2010
Inorganic mineral materials for insulation in buildings
217
8.4 Foamed glass (Source: FIW München).
therefore suitable for insulating areas like below-ground structures in contact with soil and water. Because of this inertness foamed glass has an excellent durability and does not rot or grow mould and is resistant to rats or insect attack. This makes this material ideally suited as load-bearing insulation below ground requiring national technical approvals. Depending on the particular application, the foamed glass can be supplied in different grain sizes (from 2 mm up to 50 mm). It is not suitable for acoustic applications or between timbers (too rigid).
8.5.4 Calcium silicate foam and mineral foam Calcium silicate (CS) foam boards (Fig. 8.5) made with slightly different raw materials are also known as mineral foam or mineral insulating boards. The raw materials for CS are calcium and silicon dioxide plus an aggregate of 3–6% cellulose. These are mixed with water to form a slurry and this produces calcium silicate hydrate. The cellulose content improves flexibility and edge stability. The mixture is poured into moulds and then autoclaved. The result is a fine-pore, open-cell, rigid foam which is subsequently cut into boards and treated with special additives to give it hydrophobic properties. The high service temperature and the good load-bearing property gives the foam its ideal application area in the industrial sector, and with an acceptable price/performance ratio. The use of calcium silicate foam for the building sector, especially the internal insulation of walls is relatively new. Based on extensive research, it
© Woodhead Publishing Limited, 2010
218
Materials for energy efficiency and thermal comfort in buildings
8.5 Calcium silicate foam CS (Source: FIW München).
was proven that, due to the high capillary action and hydrothermal material properties, the foam can be used to improve the moisture protection – especially when energetically renovating old buildings where the outside façade is unsuited for insulation measures. Additionally, the high pH of 10 inhibits the growth of fungus.
8.5.5 Ceramic fibres Standard ceramic fibres (Fig. 8.6) are made from inorganic materials, primarily aluminium oxide (Al2O3) and silicon dioxide (SiO2), leading to very high thermostability. Under normal circumstances standard ceramic fibres can be applied at temperatures up to 1260 °C. By adding small amounts of, e.g., zirconium oxide (ZrO2) the application temperature can be increased to approx. 1600 °C. Another type of fibre (basis: SiO2–CaO) is a synthetic fibre made from alkaline earth silicates. The fibre is soluble in the human body and consequently completely harmless from a health point of view. Such a fibre can normally be applied at temperatures up to approximately 1100 °C. Ceramic fibre products are used in areas where good insulating properties at high temperatures are wanted – for packing and for expansion joints. If there is no mechanical wear, ceramic fibres can be used as the only refractory material in contact with high temperature processes, e.g. in kilns for heat treatment of metal, glass, etc.
© Woodhead Publishing Limited, 2010
Inorganic mineral materials for insulation in buildings
219
8.6 Ceramic fibres (Source: FIW München).
Ceramic fibre is manufactured with different qualities depending on the production method: the spun and the blown fibre. A spun fibre yields the strongest, but also the most expensive product. In most fields of application the two types of fibre function in the same way, and therefore the spun fibre is the most commonly used type. Another commonly used type of ceramic fibre is blankets that are manufactured by placing the spun fibre on a conveyor belt. The belt speed and the thickness of the fibre layer determine the two most important quality parameters: density and thickness. The fibre blankets are frequently impregnated, felted, burnt and cut in order to achieve the well-known standard products. The standard fibre blankets are available in the density range 100 to 160 kg/m3 and in thicknesses from 13–50 mm. Ceramic fibres are also available as massive boards, specially designed modules and wet blankets that are impregnated with a liquid making it possible to form the fibre products into the wanted shape that will remain after heating. Because of their unique (high temperature) properties ceramic fibres are rarely used in conventional thermal insulation applications in buildings.
8.5.6 Aerogel Aerogel (Fig. 8.7) is an extremely lightweight, highly porous, solid material. Metal oxides or polymers are among the various raw materials possible.
© Woodhead Publishing Limited, 2010
220
Materials for energy efficiency and thermal comfort in buildings
8.7 Aerogel (Source: FIW München).
However, aerogel is primarily manufactured from silicates (SiO2) which convert to a gel upon addition of a catalyst. This gel is subsequently dried under extreme conditions to a non-brittle consistency. This sol–gel process was developed as long ago as 1930 and over the course of time the mix of raw materials has been varied and improved. In the meantime, pore sizes range down to 20–40 nm. With a thermal conductivity of 0.017–0.021 W/(m•K), aerogel exhibits excellent thermal insulation properties; it is also good as sound insulation and remains stable in temperatures up to approximately 1200 °C. Aerogels have a density of 60–80 kg/m3. They are resistant to moisture and mould growth and do not discolour even after long exposure to ultraviolet radiation. Since more than 40% of heat lost from an average building is through the walls, aerogel particles can be a solution for cavity wall insulation, especially in small spaces or historical buildings where a change in the building’s appearance is not acceptable. Aerogel cavity wall insulation is permanent and maintenance free. This in turn can justify the higher price compared with standard insulation materials.
© Woodhead Publishing Limited, 2010
Inorganic mineral materials for insulation in buildings
221
A new commercial development incorporates aerogels into a non-woven fabric or a fibrous blanket; this is especially useful in applications where a thin product is required that can be easily cut, rolled and shaped on the job site, i.e. as a thermal break in places that otherwise conduct heat such as over studs and around windows.
8.5.7 Pyrogenic silicic acid and vacuum insulation panels Fumed or pyrogenic silicic acid is produced by burning silicon tetrachloride in a hydrogen flame. In conjunction with a stabilizer, this produces a microporous insulating material. In order to minimize the release of radiant heat, opacifiers such as titanium oxide (TiO2) or, for high-temperature applications, zirconium oxide (ZrO2), are added. This mixture, together with reinforcing fibres, is compressed to form boards with densities of up to 300 kg/m3. Depending on the density, this results in rigid or flexible boards with a microporous structure that significantly impedes the migration of gas molecules and hence reduces the thermal conductivity to 0.020 W/m•K. These boards can be used as a core material in the manufacture of vacuum insulation panels (VIPs) (Fig. 8.8a and b). VIPs ‘transform’ the principle of the thermos bottle into a flat panel. The core material like fumed silicic acid is wrapped in a high gas barrier film or foil and then evacuated and sealed. While VIPs have been in use in high performance packaging for some time, only recently have VIPs been especially developed for the (rough) building application. The core of the panel consists of amorphous silicon dioxide powder and an inorganic opacifier; the panel is sealed under vacuum into a high barrier film or foil which can additionally be covered for protection by a special fleece [9]. During assembly at the construction site care has to be taken in handling and in tightly fitting the panels together avoiding thermal leaks due to the seams of the film covering the panels. Of course, there is no cutting option on the job site. Due to the low thermal conductivity, the drastically reduced thickness (usually 10–40 mm) allows new solutions in building applications. Figure 8.8(c) shows an exterior wall insulation system utilizing VIPs and a protective layer of polyurethane. The higher costs of the system were more than offset by the gained indoor living space (Munich, 2005). National approvals have recently been granted, e.g. by the German Institute for Building Technology. In the approval, ageing and edge losses of the panel are taken into account by fixing the design thermal conductivity at 8–11 mW/(m•K) although the initial value might be as low as 4–5 mW/ (m•K). A special manufacturing process allows for the design of cylindrically shaped products that are useful for building equipment and pipe insulation (Fig. 8.8(b)).
© Woodhead Publishing Limited, 2010
222
Materials for energy efficiency and thermal comfort in buildings
(a)
(b)
(c)
8.8 (a) Vacuum insulation panel VIP, (b) Vacuum insulation cylinder, (c) External wall insulation with VIP (Source: va-Q-tec, Würzberg, Germany). © Woodhead Publishing Limited, 2010
Inorganic mineral materials for insulation in buildings
223
8.5.8 Expanded perlite Perlite is not a trade name but a generic term for naturally occurring siliceous rock. The distinguishing feature which sets perlite apart from other volcanic glasses is that, when heated to a suitable point in its softening range, it expands to four to twenty times its original volume (Fig. 8.9). This expansion is due
(a)
(b)
8.9 (a) Expanded perlite EP, (b) Expanded perlite board EPB (Source: FIW München). © Woodhead Publishing Limited, 2010
224
Materials for energy efficiency and thermal comfort in buildings
to the presence of 2–6% water in the crude perlite rock. When quickly heated to above 900 °C, the crude rock expands as the water vaporizes and creates countless small cells which account for the light weight and other exceptional physical properties of expanded perlite. This expansion process also creates one of perlite’s most distinguishing characteristics: its white colour. While the crude rock may range from transparent light gray to glossy black, the colour of expanded perlite ranges from snowy white to grayish white. Since perlite is a form of natural glass, it is classified as chemically inert and has a pH of approximately 7. Because of perlite’s outstanding insulating characteristics and light weight, it is widely used as a loose-fill insulation in masonry construction. In this application, free-flowing perlite loose-fill masonry insulation is poured into the cavities of part of the structure where it completely fills all cores, crevices, mortar areas and holes. Lightweight brick masonry blocks with factory filled cores are available, too. In addition to providing thermal insulation, perlite enhances fire ratings, reduces noise transmission and it is rot, vermin and termite resistant. Perlite is also ideal for insulating low temperature and cryogenic vessels. When perlite is used as an aggregate in concrete, a lightweight, fire resistant, insulating concrete is produced that is ideal for roof decks and other applications. Perlite can also be used as an aggregate in Portland cement and gypsum plasters for exterior applications and for the fire protection of beams and columns. Other construction applications include under-floor insulation, chimney linings, paint texturing, gypsum boards, ceiling tiles, and roof insulation boards. The insulation boards (EPBs) (Fig. 8.9b) are usually manufactured in a process which blends the expanded perlite particles with reinforcing fibres, special binders and hydrophobic additives. For the internal insulation of walls and ceilings, a special fibre-free board has been developed, which not only reduces the heat loss but also helps to control the indoor air humidity. Composite boards, e.g. EPB in combination with mineral wool, are also offered to the market.
8.5.9 Exfoliated vermiculite Vermiculite is the geological name given to a group of hydrated laminar minerals which are aluminium iron magnesium silicates resembling Mica in appearance. Minute layers of water are trapped between the plates, and when the particles are subjected to heat (> 1000 °C) they have the unusual property of exfoliating, or expanding, due to the inter-laminar generation of steam (Fig. 8.10). A typical chemical composition is given in Table 8.13. In its exfoliated state, vermiculite has the following important qualities: low density, moderate low thermal conductivity, high temperature resistance, high absorbency, high specific surface area and cation exchange property. It is also non-toxic and sterile.
© Woodhead Publishing Limited, 2010
Inorganic mineral materials for insulation in buildings
225
8.10 Exfoliated vermiculite EV (Source: Techno-Physik Eng. Essen, Germany). Table 8.13 Typical chemical composition of exfoliated vermiculite Chemical
% by weight
SiO2 38–46 TiO2 1–3 AI2O3 10–16 Fe2O3 5–13 MgO 16–35 CaO 1–5 K2O 1–6 H2O 3–16
Exfoliated vermiculite will readily hold liquids within the inter-laminar voids of particles. It will also hold a certain amount between the individual particles. Water retained as a percentage of the air dry weight will be approximately 240%. Typical building-related applications are loft insulation and cavity fill. Exfoliated vermiculite is available as aggregate (EVA), coated (EVC), bitumen-coated (EVB), hydrophobic (EVH) and in a pre-mixed form (EVM).
8.5.10 Expanded clay Expanded clay pellets (Fig. 8.11), most commonly known under the brand names LECA (acronym of light expanded clay aggregate) or LIAPOR (porous
© Woodhead Publishing Limited, 2010
226
Materials for energy efficiency and thermal comfort in buildings
8.11 Expanded clay (Source: FIW München).
lias clay), also known as Hydroton and under the non-proprietary terms fired clay pebble, grow rocks, expanded clay (pellets) or hydrocorns, are small globes of burnt and expanded clay, used in construction and farming, and especially in hydroponics. After being thoroughly prepared, the raw clay is burnt at a temperature of about 1200 °C in a rotary kiln. During this process the organic components of the clay, which are evenly dispersed, combust. The spheres expand and expanded clay with very fine pores comes into existence. The weight, size and strength can be controlled exactly. The pellets are available in different sizes such as 4–8 mm in diameter. The dry density of lightweight expanded clay aggregates is 300 to 500 kg/m3. Expanded clay pellets offer decent insulation properties, they are lightweight and heatproof. Due to their low weight and good shear strength the product is used for lightweight fill in civil engineering structures to reduce settlement and reduce pressure on structures. The still preliminary European standard prEN 15732 describes the specifications needed for this application. Expanded clay is very open to diffusion and can absorb a considerable amount of moisture. It is an incombustible material and is also highly resistant to chemicals. Rodents and insects find no nutrients in expanded clay; however, fungi can grow on it if moisture is constantly present. When used as a thermal insulation material, expanded clay is mainly used to fill voids and, for example, contributes to improving the sound insulation of suspended floor constructions. Expanded clay is also used as an aggregate in the manufacture of masonry units and precast concrete elements, and in
© Woodhead Publishing Limited, 2010
Inorganic mineral materials for insulation in buildings
227
a small grain size for improving the insulation properties of mortar, render and plaster.
8.5.11 Insulating clay bricks (Fig. 8.12) The brickmaking industry has been offering special masonry units with a thermal conductivity of < 0.1 W/(m•K). Their insulating effect is therefore close to that of some thermal insulating materials and thus should be mentioned in this chapter. The clay content of the bricks has been reduced by optimizing the arrangement of the hole pattern to such an extent that the load-bearing capacity for normal structural requirements is still sufficient but at the same time the thermal insulating properties are considerably better than before. Additionally, the holes can be filled with an insulating material. Expanded perlite (EP) or special mineral granulate are used as a filling material; at a density of 650 kg/m3 the thermal conductivity can be as low as 0.09 W/ (m•K) for the design value. In order to reduce the mortar’s influence on the thermal conductivity of the wall, these products are constructed exclusively as precision bricks laid in thin-bed mortar.
8.6
Summary
Insulating products made from natural or synthetic mineral raw materials dominate the insulation market in Europe due to their overall cost/performance
8.12 Insulating clay brick with EP (Source: FIW München).
© Woodhead Publishing Limited, 2010
228
Materials for energy efficiency and thermal comfort in buildings
ratio or their special product properties, mineral wool products for building insulation having gained the largest market share. The versatility of the raw materials and the different production processes allow for a wide range of combinations of product properties: from commodity type insulation materials to highly specialized materials for niche-type applications in the building and the industrial sector. Very often it is the combination of thermal, fire and acoustic performance that make the materials described in this chapter the ‘product of choice’. For trading in the European market, products like mineral wool, cellular glass and expanded perlite are specified by harmonized CEN standards, while the niche-type products have either a manufacturer-specific European or national technical approval to prove to the consumer the fulfilment of regulatory requirements for the particular application.
8.7
References
1. http://eur-lex.europa.eu/ 2. Gibson, L.J. and Ashby, M.F.: Cellular Solids: Structure and Properties. Pergamon, Oxford (1988). 3. Danner, H.: Comparison of ecological insulating materials, Munich, www.muenchen. de/bauzentrum (2008). 4. EN 13162: (2008) Thermal insulation products for buildings – factory made mineral wool (MW) products – specification. 5. EN 13167: (2008) Thermal insulation products for buildings – factory made cellular glass (CG) products – specification. 6. EN 13169: (2008) Thermal insulation products for buildings – factory made products of expanded perlite (EPB) – specification. 7. ISO TR 9774: (2004) Thermal insulation for building applications – guidelines for selecting properties. 8. Pfundstein, M., Gellert, R., Spitzner, M.H. and Rudolphi, A.: ‘Insulating materials’, Edition Detail, Institut für internationale Architektur – Dokumentation GmbH & Co. KG, Munich, Germany (2007); English version: distributed by Birkhäuser – Publishers for Architecture, Basel, Switzerland (2008). 9. DIN 4108-4: (2004-07) Thermal insulation and energy economy in buildings – Part 4: Hygrothermal design values. 10. DIN V 4108-10: (2004-06) Thermal insulation and energy economy in buildings – application-related requirements for thermal insulation materials – Part 10: Factory made products.
© Woodhead Publishing Limited, 2010
9
Natural fibre and fibre composite materials for insulation in buildings
R. G e l l e r t, FIW München, Germany
Abstract: Insulating materials from natural organic raw materials have gained a small (4–6%) but growing market share in Europe in the last fifteen years. On the one hand, this consumer acceptance is based on the fulfilment of regulatory requirements, i.e. conformity with recently published European standards and/or the issue of European Technical Approvals (ETA). On the other hand, the growing awareness of the public towards ecological performance of building materials has given niche-type products from natural sources a certain boost, and increasingly recently-erected – often called ‘green buildings’ or ‘eco-buildings’ – can be found throughout Europe. Key words: cellulose fibres, cereal granulate, coconut fibres, cotton, flax, hemp, cork, reeds, sea grass, sheep’s wool, straw bales, wood chippings, wood fibres, wood wool.
9.1
Introduction
Insulating materials and products are usually classified into two major groups depending on the raw materials used for their production, i.e. ∑ ∑
inorganic or mineral insulating materials organic insulating materials.
The latter is further subdivided into ∑ ∑
synthetic organic and natural organic insulating materials
Although the so-called natural products may contain varying amounts of additives such as fire retardants, binders or substances to improve mechanical and moisture repellent properties, they are usually offered as ‘natural’ to the market. Products based on the raw materials in Table 9.1 can be found in the market for this particular application. Some of the materials listed in Table 9.1 are relatively rare or no longer commonly used, in particular peat and giant Chinese silver grass. Generally This chapter is dedicated to Dr Walter F. Cammerer on the occasion of his 90th birthday.
229 © Woodhead Publishing Limited, 2010
230
Materials for energy efficiency and thermal comfort in buildings
Table 9.1 Natural organic raw materials employed for the manufacture of insulating materials and products Insulating materials Inorganic
Organic
Synthetic
Natural raw materials
Cellulose fibres Cereal granulate Coconut fibres Cotton Flax (Giant Chinese silvergrass) Hemp Cork (Peat) Reeds Sea grass Sheep’s wool Straw bales Wood chippings Wood fibres Wood wool
Table 9.2 Market share of insulating materials and products in Germany [1] Product/ year
Market share (%) MF
EPS
XPS
PUR/PIR
Others
1989 1994 1999 2000 2003 2004 2005
59 60 58 58 58 55 56
32 32 28 28 28 28 29
3 3 4 4 5 6 6
5 4 4 5 5 5 5
1 1 6 5 4 6 4
MF = EPS = XPS = PUR/PIR = Others =
mineral fibre products. expanded polystyrene. extruded polystyrene foam. polyurethane foam/polyisocyanurate foam. including products from natural organic raw materials.
Total market (Mio. m3) 16 28 34 34 27 27 24
speaking due to the increasing cost for energy, the sale – and use – of insulating materials and products for the housing sector has risen in the European market during the last two decades. Table 9.2 illustrates the market growth since 1989 for Germany – with a slump of 20% in recent years – but the market recovered in 2006 and 2007. As can be noted the market shares have hardly changed over the years due to the individual price/performance characteristics of each product (group) compared with the others. Products
© Woodhead Publishing Limited, 2010
Natural fibre and fibre composite materials for insulation
231
based on natural organic raw materials have gained some market share in recent years – most likely not only based on their performance but also based on their (more) ecological image. Within this group one can find the market share distribution in Germany shown in (Table 9.3). Most of the aforementioned products are supplied to the market in one of the four forms of supply listed in Table 9.4.
9.2
Regulatory requirements
In order to bring transparency into the European market for manufacturers and designers, and to guarantee legal security for all those involved, national regulations have been subject to a process of harmonization at the European level. The current transitional phase is characterized by the coexistence of European and national regulations, the validity of which must be carefully considered. Table 9.3 Market share of insulating materials from natural organic sources (Germany 2004) [1] Product
Market share (%)
Cellulose (LFCI) Wood fibre (WF) Wood wool (WW) Flax/Hemp Sheep’s wool Others
32 28 20 9 4 7
Table 9.4 Forms of supply of products made from natural organic raw materials Material/Product
Forms of supply
Boards, batts Loose-fill
Blown or caulking materials
Wood-fibre ∑ ∑ Wood wool (incl. composites) ∑ Insulation cork board ∑ ∑ Cotton ∑ ∑ Flax ∑ ∑ Cereal granulate ∑ Hemp ∑ ∑ Coconut fibres ∑ ∑ Sheep’s wool ∑ Reeds ∑ ∑ Cellulose fibres ∑ ∑ Sea grass ∑ ∑ Wood chippings ∑ Straw bales ∑
© Woodhead Publishing Limited, 2010
Sandwich
∑
232
Materials for energy efficiency and thermal comfort in buildings
It was in 1989 that the ‘Council Directive 89/106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of the Member States relating to construction products (89/106/EEC)’ was published in the Official Journal of the European Communities (OJ). This so-called Construction Products Directive (CPD) states that construction products – and the technical specifications that describe them – must be of such a form that their use does not have a detrimental effect on the levels of safety and protection that apply to the construction works. Such levels can vary, depending on the location of the works, their use or other circumstances. The levels of safety and protection are divided into six primary requirements listed in Annex I of the CPD: 1. Mechanical resistance and stability 2. Safety in case of fire 3. Hygiene, health and the environment 4. Safety in use 5. Protection against noise 6. Energy economy and heat retention. For the implementation of the CPD, the European Commission has provided detailed explanations and commentaries of individual parts in the form of interpretive documents and Guidance Papers; the Member States and the CEN (Comité Européen de Normalisation – European Committee for Standardisation) have to take into account these non-binding documents in their national legislation. The above-mentioned technical specifications that describe construction products, e.g. thermal insulating materials and products, will normally be either harmonized standards or European Technical Approvals. ∑
∑
Harmonized standards (hEN) [2–4] are technical rules drawn up on the basis of mandates of the Commission of the European Communities by the European standardization organizations with respect to the essential requirements; they are implemented in corresponding national standards (e.g. as DIN EN or BS EN). Normally, national and state governments contribute to the drafting of harmonized standards within the scope of the participation of interested parties in order to incorporate into European standardization the latest technical requirements. European Technical Approvals (ETA) are favourable technical assessments of fitness for an intended use issued to a manufacturer for his construction products by certain Approval Bodies according to this law or the legislation adopted by other Member States of the European Union or other contracting states to the agreement on the European Economic Area (EEA).
Binding legislation on the one hand and standards and approvals on the
© Woodhead Publishing Limited, 2010
Natural fibre and fibre composite materials for insulation
233
other hand have created an extensive set of rules and regulations covering the manufacture of insulating materials and their use in construction. The standards and approvals are by definition not mandatory, but do become so when statutory instruments make reference to them. Table 9.5 lists the existing standards, preliminary standards or approvals for the insulating materials and products described in this chapter. As the standards for the factory made products were written according to a ‘model standard’ and published as a ‘package’, the three standards listed in Table 9.5 all have an identical structure: in the ‘heart of the standard’ one will find the requirements, the test methods, the designation code, the rules for the attestation of conformity and the rules for marking and labelling. Due to the ‘in-situ-situation’ the standard – still in the preliminary stage – for cellulose fibre is written in two parts: one addressing the (basic) raw material, the second part describing the ‘conversion’ from a loose-fill material into a thermal performance product on site. Based on properties to be declared for all applications and also – if declared by the manufacturers – for specific application one can summarize important standardized performance criteria in a table (Table 9.6). As shown in Table 9.5, most products under consideration here are placed on the market via a European Technical Approval (ETA) – issued specifically to the particular manufacturer. An ETA can be granted when any of the following conditions apply: Table 9.5 European technical specifications for insulating materials based on natural organic raw materials [2–4] No. Product
Abbreviation
Technical specification
Factory made In-situ application 1 Wood wool and WW EN 13168: composites WW-c 2001-05a 2 Wood fibre WF EN 13171: 2001-05a 3 Cork board ICB EN 13170: 2001-05a 4 Cellulose fibres LFCI Insulating materials based on natural fibres (except 1–3) ETAb
Loose-fill materials based on natural fibres (except 4)
All others
a
ETAb
pr EN 15101
ETAb ETAb
Recent additions and corrigenda have been published (www.cen.eu). Individual companies are holders of approvals (www.eota.be).
b
© Woodhead Publishing Limited, 2010
234
Materials for energy efficiency and thermal comfort in buildings
Table 9.6 Standardized properties, relevant test methods and designations Property
Test method Symbol Dimension 2
Thermal resistance EN 12667 or RD m •K/W EN 12939 l D W/(m•K) Length and width EN 822 l and b mm Thickness EN 823 d mm Squareness EN 824 mm/m Flatness EN 825 mm Dimensional stability under EN 1603 De % normal laboratory conditions Bending strength EN 12089 sB kPa Reaction to fire EN 13501-1 (Euroclasses) Moisture content EN 12105 % (w/w) Apparent density EN 1602 ra kg/m3 Dimensional stability under EN 1604 De % specified temperature Dimensional stability under EN 1604 De % specified temperature and humidity conditions Deformation under EN 1605 e % compressive load Compressive stress at 10% EN 826 s10 kPa deformation Tensile strength EN 1607 smt kPa perpendicular to the faces Point load EN 12430 N Compressive creep EN 1606 ect % Shear strength EN 12090 t kPa Water absorption, short term EN 1609 kg/m2 Water vapour transmission/ EN 12086 m m2•h•Pa/mg resistance factor Dynamic stiffness EN 29052-1 s¢ MN/m3 Thickness EN 12431 dL mm Thickness dB Compressibility dL–dB c mm Sound absorption EN ISO ap — 354:1993/A1 aw Air flow resistance EN 29053 kPa•s/m3 Chloride content EN 13168-C.1 %
Designation R, l L and W T S P or Smax DS (N) BS A, B, C, D, E, F H DS(T) DS(T, H)
DLT CS(10) TR PL(P) CC( )sc WS Z or MU SD
CP AP/AW AF Cl
∑ ∑
no relevant harmonized standard for the product exists no mandate for such a standard has been given by the European Commission ∑ the European Commission considers that a standard cannot be developed (yet) ∑ a product deviates significantly from the relevant harmonized standards. In conjunction with an ‘Attestation of Conformity procedure’ (which is intended
© Woodhead Publishing Limited, 2010
Natural fibre and fibre composite materials for insulation
235
to ensure that the product specification set out in an ETA is maintained by the manufacturer), ETAs allow manufacturers to place the CE marking on their product(s). Although in certain circumstances it may be possible for an ETA to be issued on the basis of a common assessment procedure agreed among EOTA members (according to the art. 9.2 of the Council Directive 89/106/EEC), in most cases an ETA for a product will be granted to a manufacturer based on the assessment principles set out in an ETA Guideline for the relevant product sector. When a European Technical Approval has been issued it is valid in all EEA countries, for a period of five years, renewable thereafter. The European Organization for Technical Approvals (EOTA) lists ETA documents, the type of products and the manufacturer on its home page (www.eota.be). Both routes lead to the CE marking on the insulating products.
9.3
Building-related properties
Because of its importance as the most important building-related property, in the European system for declaring the thermal conductivity lD (or the thermal resistance RD respectively) the following details can be given: ∑ The declared thermal conductivity lD is determined on the basis of statistically evaluated measurements (l90/90) – to be organized by the manufacturer. Details are given in the respective product standard (usually in a normative Annex); lD is declared in steps of 0.001 W/m • K. ∑ Design values for the particular building application are defined nationally – due to different building codes and/or the climate in question. An overview of the basic building-related properties is given in Table 9.7, some specific properties of interest here in Table 9.8. Besides the ‘core properties’ which determine the performance of an insulating material, some products have good acoustic or specific fire performance characteristics that the manufacturer wishes to declare – or has to declare for a certain application – already when placed onto the market, i.e. the reaction to fire classification. The latter has now been based on the European (classification) standard EN 13501 and the following Euroclasses with respect to the combustibility of building materials (reaction to fire) have been agreed upon: ∑ A1 + A2 No contribution to a fire/non-combustible ∑ B Very limited contribution to a fire ∑ heat propagation ∑ flame propagation ∑ smoke propagation
© Woodhead Publishing Limited, 2010
236
Materials for energy efficiency and thermal comfort in buildings
Table 9.7 Typical building application related properties [5–7] Material
Property
Thermal conductivity l Da (mW/(m•K))
Woodwool (WW) Wood fibres (WF) Cork board (ICB) Cellulose fibres (LFCI) Hemp (mats) Sheep’s wool Cotton Flax Cereal granulate Reeds Coconut fibres Sea grass Wood chippings Straw bales
90–110 350–600 40–55 160–250 42–50 100–220 40–45 35–60 40–50 24–42 40–45 18–30 40 20–60 40 20–80 50 105–115 55–90 120–225 40–50 70–120 43–50 75 45–55 70–140 38–72 90–110
a
Density r (kg/m3)
Specific heat capacity C (J/(kg•K))
Water vapour diffusion resistance m
2100 2100 1800 2200 1600 1700 1300 1600 1950 1200 1600 n.a. 2100 n.a.
2–5 5–10 5–10 1–1.5 1–2 1–5 1–2 1–2 2–3 2–5 1–2 n.a. 1–2 n.a.
Declared thermal conductivity by the manufacturer.
Table 9.8 Selected specific properties based on manufacturers’ declarations (where given) [5] Material/Product
Specific property
Compressive Tensile strength stress at 10% perpendicular deformationa to facesb (kPa) (kPa)
Maximum service temperature Short- longterm term (°C) (°C)
Woodwool (WW) 150–200 2.5–50 180 110 Wood fibres (WF) 40–200 2.5–50 n.a. 110 Cork board (ICB)c 100–200 30–50 180–200 110–120 Cellulose fibres (LFCI) — n.a. 60 Cellulose fibres (boards) 2.5 Hemp (mats) Sheep’s wool 500 130–150 Cotton < 400 100 Flax Cereal granulate Reeds Coconut fibres Sea grass Wood chippings Straw bales 120 100 a
EN 826 EN 1607 c ICB not bitumenised b
© Woodhead Publishing Limited, 2010
Natural fibre and fibre composite materials for insulation
∑ C ∑ D ∑ E ∑ F
237
Limited – but some – contribution to a fire Not negligible contribution to a fire Poor fire reaction properties ∑ acceptable ignitability ∑ limited flame propagation No performance determined – no data available
Table 9.9 summarizes those properties. The properties outlined above in the various tables – in short the performance characteristics – have led the products made from natural raw materials to be used in certain applications which can best be visualized in a matrix (Table 9.10). Based on the European technical harmonization, the EU Member States are responsible for developing rules for the specific use of insulating materials in construction works, e.g. in roofs or walls – as outlined in Table 9.10 for Germany as an example.
9.4
Ecological and health aspects
So far those product characteristics that have been described reflect the more technical performance, i.e. mechanical strength, fire protection, sound insulation and, of course, thermal insulation. Table 9.9 Properties related to acoustic and fire performance (manufacturers’ declarations – where given) [5] Material/Product Euroclasses
Acoustics Dynamic Sound impedance stiffnees per unit length s¢ r (MN/m3) (kPas/m2)
Woodwool (WW) 4–8 9–100 Wood fibres (WF) 4–8 9–100 Cork board (ICB) Cellulose fibres (LFCI) — 3.6–20 Cellulose fibres (boards) 3–7 43–76 Hemp (mats) — > 6 Sheep’s wool Cotton Flax — > 2 Cereal granulate Reeds Coconut fibres Sea grass Wood chippings Straw bales
© Woodhead Publishing Limited, 2010
Reaction to fire acc. to EN 13501-1 B-s1, d0 E E E E B-s2, d0 to C-s2, d0
Straw bales
Wood chippings
Sea grass
Coconut fibres
Reeds
Cereal granulate
Flax
Cotton
Sheep’s wool
Cellulose fibres
Hemp
Insulation cork board (ICB)
Wall External insulation of walls, behind cladding External insulation of walls, behind waterproofing
Materials for energy efficiency and thermal comfort in buildings
© Woodhead Publishing Limited, 2010
Floor and roof External insulation of upper floors or roofs, protected from the weather, insulation below roof covering External insulation of upper floors or roofs, protected from the weather, insulation below waterproofing External insulation of roofs, exposed to the weather (inverted roof) Insulation between rafters, double-skin roofs, accessible but non-trafficked topmost floor Internal insulation of upper floors (underside) or roofs, insulation below rafters/structure, suspended ceiling, etc. Internal insulation of upper or ground floors (top side) below screed, without sound insulation requirements Internal insulation of upper or ground floors (top side) below screed, with sound insulation requirements
Wood fibres (WF)
Products from natural raw materials Wood wool (WW)
Application
238
Table 9.10 Application matrix (based on the German DIN V 4108–10) [5], [7]
© Woodhead Publishing Limited, 2010
Basement External thermal insulation of walls in contact with soil (on outside of waterproofing) External thermal insulation below ground floor slab in contact with soil (below waterproofing) with standardized properties with building authority approval for the product for this application rarely used as thermal insulating material
Natural fibre and fibre composite materials for insulation
External insulation of walls, behind render Cavity insulation of double-leaf walls Insulation to timber-frame and timber-panel constructions Internal insulation of walls Insulation between partition walls with sound insulation requirements Insulation to interior walls
239
240
Materials for energy efficiency and thermal comfort in buildings
The ‘Essential Requirement 3 (ER 3)’ of the European CPD demands that construction works should not endanger users through any of the following: ∑ ∑ ∑ ∑ ∑ ∑
the giving-off of toxic gas the presence of dangerous particles or gases in the air the emission of dangerous radiation the pollution or poisoning of the water or soil the faulty elimination of wastewater, smoke, solid or liquid wastes the presence of damp in parts of the works or on surfaces within the works.
Given the origin of the products described in this chapter, they will most likely contribute to a healthy ‘building environment’. In order to fulfil all mandatory building-related performance criteria, additives have to be used to meet these requirements. ∑
Reaction to fire: since in many countries at least Euroclass E has to be fulfilled by construction products, flame retardants are being added; in use are usually aluminium hydroxide, ammonium phosphate, -sulfate, borax, boric acid and others. ∑ Mechanical performance: in order to improve the dimensional stability artifical (polyester) fibres are added. ∑ Resistance against biological attack: the proof of the resistance of the product is usually based on an EOTA test procedure (‘factory-made thermal insulation material and/or acoustic insulation material made of vegetable or animal fibres’ Edition June 2003, Rev. 1 June 2005). The (possible) growth of fungus has to be judged based on EN ISO 846: 1997-06, Table 4 and should yield the classification ‘0’. The so-called ‘eco-balance’ takes into consideration all stages of the life cycle, i.e. acquisition, production, use and end-of-life plus transportation for combining the different stages. For a specific use-phase Table 9.11 gives a comparison of the most important ecological parameters. Provided that in the near future data and parameters for all insulation materials are generated on a standardized basis, the end-user can choose their product both on the technical and the ecological performance checklist. However, one should keep in mind that no matter which approved insulating product is chosen, the ‘return-on-energy investment’ is – depending on the climate – usually one heating period.
9.5
Individual product profiles
9.5.1 Woodwool (composite) boards (WW) (Fig. 9.1) The boards or slabs are made from long shavings of softwood and are bonded by the use of an inorganic cement agent. In the composite woodwool © Woodhead Publishing Limited, 2010
Ecological parameter b
Material property
© Woodhead Publishing Limited, 2010
Material/Product
PE-Input GWP APd Calorific value (MJ/kg) (MJ/m3) (kg CO2-eq./m2) (kg SO2-eq./kg)
Density Thickness ~ (kg/m3) (m)
Lambda lD (W/m•K)
Woodwool (WW) Wood fibres (WF) Cork board (ICB) Cellulose fibres (LFCI) Cellulose fibres (boards) Hemp (mats) Sheep’s wool Flax Wood chippings
17.0 18.0 16.7 24.7 17.0 16.0 20.4 12.3 18.0
520 160 120 40 80 25 30 30 80
0.090 0.045 0.045 0.040 0.040 0.045 0.040 0.040 0.045
a
a
728 447 230 38 142 53 48 116 47
c
122.877 –9.110 –23.744 –4.570 7.390 –1.950 –0.076 1.405 –11.844
0.422 0.024 0.051 0.005 0.056 0.024 0.011 0.005 0.014
Calorific value: Can be gained in a later combustion process. PE-Input: Primary energy input covering all energy used to manufacture the product. c GWP: Global warming potential. d AP: Acidification potential. b
0.28 0.14 0.14 0.13 0.13 0.14 0.13 0.13 0.14
Natural fibre and fibre composite materials for insulation
Table 9.11 Ecological performance based on standardized conditions (U-value = 0.3 W/m2K; PE-investment = 0.22 W/m2K) [1]
241
242
Materials for energy efficiency and thermal comfort in buildings
9.1 Woodwool WW (Source: FIW München).
slabs the woodwool is bonded with a mineral binder; on one or both face(s) another insulating materials, e.g. mineral wool or a foamed rigid cellular plastic can be bonded.
9.5.2 Wood fibre (WF) (Fig. 9.2) Insulation products are manufactured from wood fibres with or without the addition of bonding agents and/or additives; some products are only mechanically bonded. Depending on the bonding agent the product(s) can be supplied either as mats, batts, felt, rolls or lamella rolls. In the latter case strips of wood fibre boards are bonded to a flexible facing and supplied in a bond. This will lead to a continuous insulating layer when the product is unrolled.
9.5.3 Cork-board (ICB) (Fig. 9.3) The protective layer of the cork oak tree (Quercus suber L.) is periodically removed from its trunk and branches to provide the raw material for cork products. The cork is granulated by grinding and/or milling. From this the pre-formed product is made by expansion and bonding exclusively with its own natural binder by heating under pressure.
© Woodhead Publishing Limited, 2010
Natural fibre and fibre composite materials for insulation
9.2 Wood fibre WF (Source: FIW München).
9.3 Cork-board ICB (Source: FIW München).
© Woodhead Publishing Limited, 2010
243
244
Materials for energy efficiency and thermal comfort in buildings
9.5.4 Cellulose fibres (LFCI) (Fig. 9.4) Loose-fill cellulose insulation (LFCI) is a fibre or fibrous or granulated insulation material derived from paper, paper stock and/or wood, leaf or stalk strings with or without binders. The product is blown, injected or applied with or without moisture. The insulation system usually consists of a particular type of loose-fill cellulose used in conjunction with a blowing machine with a blowing hose and nozzle attached to a hole which is cut or formed into a masonry cavity or frame construction through which the cellulose is blown.
9.5.5 Hemp (Fig. 9.5) Insulating products are either made from the fibres of the hemp plant (Cannabis sativa) or the shives (Fig. 9.6). Supporting fibres (usually from polyester) are used to give the mats mechanical support; starch is sometimes used to bind small layers of hemp fibres. Additives (salts of boric acid) are used to give the product its flame retardant property. Shives can be impregnated and then either formed into boards or used as loose-fill material. The proper ratio of hemp shives and lime has been combined into a bicomposite building material with excellent thermal and acoustic properties.
9.4 Cellulose fibres LFCI (Source: FIW München).
© Woodhead Publishing Limited, 2010
Natural fibre and fibre composite materials for insulation
245
9.5 Hemp mats (Source: FIW München).
9.6 Hemp shives (Source: FIW München).
9.5.6 Sheep’s wool (Fig. 9.7) Raw or recycled wool from sheep is run through a cleaning process and then treated with additives such as the salts from boric acid or urea derivatives to give it flame retardant and moth repellent properties. Often supporting polymeric fibres (polyester) are added.
© Woodhead Publishing Limited, 2010
246
Materials for energy efficiency and thermal comfort in buildings
9.7 Sheep’s wool (Source: FNR, Gülzow, Germany).
9.5.7 Cotton Similar to sheep’s wool, cotton can be converted directly into an insulating material, using the same additives to give the rolls or batts the needed properties for the building application. Rarely loose flakes of cotton are used as blown insulation material.
9.5.8 Flax (Fig. 9.8) Only the short fibres of the flax plant are used to manufacture a fleece; additives similar to the ones used for hemp mats are used to give the product the needed performance characteristics.
9.5.9 Cereal granulate (Fig. 9.9) An extrusion process is used to obtain this loose-fill insulation material from fine rye grains, rye pulp and other additives – especially to introduce the needed resistance to mould, insects and rodents. The product is used in particular when cavity walls in wooden constructions have to be insulated.
9.5.10 Reeds (Fig. 9.10) The stalks of reed plants are positioned in a great number, pressed slighty and then bound together with the help of iron wire or nylon threads. Further
© Woodhead Publishing Limited, 2010
Natural fibre and fibre composite materials for insulation
9.8 Flax (Source: FNR, Gülzow, Germany).
9.9 Cereal granulate (Source: FIW München).
© Woodhead Publishing Limited, 2010
247
248
Materials for energy efficiency and thermal comfort in buildings
9.10 Reeds (Source: FIW München).
9.11 Coconut fibres (Source: FIW München).
additives are not used. However, the product is only used in regions where there is a tradition of employing this material.
9.5.11 Coconut fibres (Fig. 9.11) The fibres of the coconut shell are used to produce this insulating material; for 1 m3 of product, roughly 700 to 1600 coconuts are needed. Additives are employed to give the product flame retardant properties.
© Woodhead Publishing Limited, 2010
Natural fibre and fibre composite materials for insulation
249
9.5.12 Wood chippings (Fig. 9.12) This insulating material is usually part of an industrial process where prefabricated wooden houses are being manufactured. The waste chippings are impregnated with additives to give them a fire retardant property – and then blown as loose-fill into, e.g., cavity walls; some compaction is required.
9.5.13 Straw bales (Fig. 9.13) As a by-product of agricultural production this raw material is readily available. After cutting the straw to the right length and reducing the moisture content, the product can be used as a loose-fill material or – similar to reed – converted into batts of rather thick proportions.
9.6
Reference buildings
Although many of the above-mentioned materials have been used for generations in different climate conditions – often as traditional building material – only recently can reference objects be cited where the use is extensively documented, especially under energy-saving criteria. The ‘Agency for Renewable Raw Materials’ in Germany has recently published a list of reference objects – although currently only available in German [8]. Three examples are described in more detail in this section –
9.12 Wood chippings (Source: FIW München).
© Woodhead Publishing Limited, 2010
250
Materials for energy efficiency and thermal comfort in buildings
9.13 Straw bales (Source: FIW München).
more extensive literature, e.g. describing the use of straw bales, can be found elsewhere [9].
9.6.1 Example 1: ‘Werlte Climate Centre’ (Fig. 9.14) This example describes the reconstruction of former barracks into a model house for renewable energy and renewable resources within the perimeters of the ‘Perspective 50Plus’ project and was funded by the Federal Ministry for Labor and Social Affairs (BMAS) of Germany. From 1968 to 2005 the former company building was part of the ‘Hümmling barracks’. The reconstruction to a model house took place within the parameters of an employment project with simultaneous qualification for elderly unemployed. The building, with a usable area of approx. 2000 m 2, was redeveloped while taking aspects of energy saving into consideration and using renewable resources. Heating has since changed to vegetable oil (communal heating/power station), and also supplies the neighbouring office building. The climate centre became a reference facility with role model character. Several isolating façade systems are an example of the energetic refurbishment of an old building with renewable resources. These are unique
© Woodhead Publishing Limited, 2010
Natural fibre and fibre composite materials for insulation
251
9.14 Werlte Climate Centre (Source: www.3-m.info, Emsland, Germany).
nationwide, equipped with over 50 sensors and supplying continual data regarding the temperature and humidity. The roof is provided half with insulation between the rafters and insulation of the loft. Good insulation and a healthy room climate are also prominent in the selection of windows and flooring of wood, linoleum and tiles. Approx. 99 tons of CO2 and 1600 litres of heating oil are saved every year as a result of improved insulation. The climate centre was launched in 2008. The responsible bodies are the administrative district of Emsland and the community of Werlte (Germany). With its exhibition areas and the information it provides, the climate centre has become a forum for companies, consumers and research. Several exhibition areas present modern bio energy technology and regenerative energy efficiency. More than 30 exhibitors present their products and services here. Construction date: 2006–2008 Energy consumption: After redevelopment: a saving of approx. 99 tons of CO2 and 1600 litres of heating oil per year. Exterior wall 10 different façade systems with insulation construction: materials from renewable resources (wood fibre, cellulose and meadow grass) are available for practice testing and data gathering. Example for façade 1 (from inside to outside): 1.5 cm plaster
© Woodhead Publishing Limited, 2010
252
Materials for energy efficiency and thermal comfort in buildings
Floor construction:
Roof construction: Surface treatment: Heating method: Solar industrial water heating: Photovoltaic: Rainwater use:
24.0 cm lime sand bricks 12.0 cm wood fiber boards 2.0 cm building slab HD plastered Insulation of the roof with different variations Partition 1: Insulation of the loft with piled insulation from sea grass and cellulose. Construction: OSB sheathing (19 mm thick) lie on upright cardboard sleeves (40 cm high) as the loadbearing component. Cavities and sleeves are filled with the insulation material. Partition 2: Under rafters insulation with various products: 1. Sector: 40 cm cellulose, 2. Sector: 40 cm meadow grass, 3. Sector: 40 cm perlite (the rafter thickness is predetermined by the old building) Walls and floors: Installation of wood floors, linoleum and tiles and the application of ecological paints. Adjacent heating network (communal heating/power station) with vegetable oil (test facility with pellet and woodchip heating for demonstration purposes). no yes no
9.6.2 Example 2: Kindergarten in Döbeln Directly next to the Jakobikirche in Döbeln, the Evangelist-Lutheran church parish built a new kindergarten. Similar to a convent, the St. Florian kindergarten forms a constructional unit with the church; a cloister with an inner courtyard joins the buildings together. After the 2002 Mulde flood the replacement new building had become necessary. The modern colourful wood construction stands self-confidently next to the 19th century church; both mutually enhance each other in their effect. You enter the single story kindergarten from the street, then your eyes continually wander from the foyer through the large glass façade to the northerly situated church. The carmine red glazed loam wall with built-in cloakrooms separates the hallway from the southerly situated group rooms. Via large doors with glass side sections, the children enter their play rooms with their own wooden galleries and bathrooms. The 68 day nursery and kindergarten children can go directly into the garden from their four group rooms. Everywhere you can detect the wonderful smell of wood and loam; this is thanks to the construction method
© Woodhead Publishing Limited, 2010
Natural fibre and fibre composite materials for insulation
253
with healthy building materials and the controlled ventilation. This system is located visibly behind a glass wall over the northerly situated adjoining rooms. The concept of the ecological passive house was very well adopted by the building owners and the children. Construction date: Size:
April 2004–March 2005 554 m 2 (3172 m 3 ), kindergarten for 68 children Energy consumption: 15 kWh/(m2a) Total costs: 71.3 m Exterior wall construction: 2 cm loam rendering on 70 stem reed panels 2 cm OSB sheathing as bracing wood panel 35 cm cellulose insulation between wood double T-sections 4 cm soft wood fibre boards 3 cm rear ventilation 2.4 cm horizontal larch wood boarding Floor/ceiling construction: 2.4 cm industrial parquet 5 cm cement screed 12 cm heat insulation 25 cm floor boards 12 cm perimeter insulation from XPS Roof construction: 2 cm OSB sheathing as bracing panel 35 cm cellulose insulation between wood double T-sections 4 cm soft wood fibre boards 12 cm rear ventilation space with ventilating rafters 3 cm planed and edged plank boards 0.5 cm roof sealing 6 cm green roof Wall and floor surfaces All interior walls are masonry loam walls treatment: with loam rendering on 70 stem reed panels and loam rendering after that glazed with plant pigments Energetic concept: Heating method: Passive house, no individual heating method since it is attached to the church Solar industrial water heating: yes Photovoltaic: no Rainwater usage: yes Purification plant: no
© Woodhead Publishing Limited, 2010
254
Materials for energy efficiency and thermal comfort in buildings
9.6.3 Example 3: ‘Passive house’ in Esslingen The property is situated in a new construction area on the outskirts of Esslingen/Neckar (Germany) with a very rigid development plan. Ground area, construction window, number of stories and flat roofs are the guidelines. Flanked by the access road on the north side, the property falls away slightly towards the south. The construction company wanted a four person residential family dwelling that should be constructed as a passive house from ecological and sustainable materials. The building complies with the development plan and was built as a simple cube. The dwelling’s rooms face to the south and their large window areas contribute towards an optimal usage of solar energy. The north and east façades are very limited in their openings, a narrow staircase window serves as a connecting component between the floors. An approved penthouse floor as well as filter and transition zones between inner and outer rooms can be added on at a later date. Enclosures walls of the lower floor are constructed with water impermeable concrete due to the risk of water damage from the slopes and backwater. The staircase walls act as a system boundary between heated and unheated areas and are constructed with a highly insulated 30 cm strong porous concrete with an additional 18 cm of XPS. Heat bridges in the concrete ceiling are consequently prevented by the insertion of Isokorbs. The walls, ceiling and roof are constructed in wood frame design and are prepared complete in the joiner’s workshop. Straw bales as insulation material were built into the stud cavities and plated, the preconstruction was then transferred to the construction site by a truck crane. In this way the shell could be constructed on site and made rainproof within two days. Thus deviating from the supervisory construction approval, the approval was obtained individually. In regard to the building materials, attention is paid to a sensible and sustainable selection. In particular, regarding this, the straw bale insulation contributes significantly. The straw bales are delivered directly to the joiner’s workshop from the producer by tractor and are therefore, in production, to be appraised with the least primary energy costs. The roof is to be ‘greened’ with a 35 l/m2 storage capable structure. Surplus water is collected in a 3 m3 cistern. The building is to be designed and constructed as a passive house, that is to say, heat loss via the shell surfaces is minimized. The solar energy supplied by the large surface glazing is retained in the house and is transferred via a ventilation system with heat recovery to fresh air. Heating, ventilation and hot water preparation is undertaken by a passive house compact appliance that provides energy with an extracted air heat pump. Construction date: Size: Energy consumption:
2008/2009 15 kWh/(m2a) heating requirements
© Woodhead Publishing Limited, 2010
Natural fibre and fibre composite materials for insulation
255
Exterior wall construction: 12 mm plaster fibre board 50 mm installation layer, soft wood fibre boards 15 mm OSB sheathing 400 mm insulated studs (stud cavities filled with straw bale insulation) DWD 16 mm, UK 24 mm Larch form boards 24 mm Floor/ceiling construction: 16 mm parquet 50 mm tile floor finish 300 mm EPS 030 insulation Roof construction: 12 mm plaster fibre board 24 mm formwork with replaceable faces Variable vapour barrier 450 mm insulated studs (stud cavities filled with wood fibre injected insulation) Wall and floor surfaces treatment: Energetic concept: Heating method: heating and cooling via compact appliance, air fan heating Photovoltaic: no Rainwater usage: yes Purification plant: no
9.7
Summary
Insulating materials from natural organic raw materials have gained a small (4–6%) but growing market share in Europe in the last fifteen years. On the one hand, this consumer acceptance is based on the fulfilment of regulatory requirements, i.e. conformity with recently published European standards and/or the issue of European Technical Approvals. On the other hand, the growing awareness of the public towards ecological performance of building materials has given niche-type products from natural sources a certain boost, and increasingly recently-erected – often called ‘green buildings’ or ‘ecobuildings’ – can be found throughout Europe. Since most of these products are fairly new to the market, a careful monitoring of the physical performance, especially with respect to building properties, is advisable.
9.8
References
1. Danner, H., Comparison of ecological insulating materials, Munich, www.muenchen. de/bauzentrum (2008). © Woodhead Publishing Limited, 2010
256
Materials for energy efficiency and thermal comfort in buildings
2. EN 13168: 2001-05 Thermal insulation products for buildings – factory made wood wool (WW) products – specification. 3. EN 13170: 2001-05 Thermal insulation products for buildings – factory made products of expanded cork (ICB) – specification. 4. EN 13171: 2001-05 Thermal insulating products for buildings – factory made wood fibre (WF) products – specification. 5. Pfundstein, M., Gellert, R., Spitzner, M.H. and Rudolphi, A., ‘Insulating materials’, Edition Detail, Institut für internationale Architektur – Dokumentation GmbH & Co. KG, Munich, Germany (2007); English version: distributed by Birkhäuser – Publishers for Architecture, Basel, Switzerland (2008). 6. DIN V 4108-4: 2004-07 Thermal insulation and energy economy in buildings – Part 4: Hygrothermal design values. 7. DIN V 4108: 2004-06 Thermal insulation and energy economy in buildings – application-related requirements for thermal insulation materials – Part 10: Factory made products 8. www.natur-baustoffe.info/index (in German only) 9. Jones, B., Building with Straw Bales: A Practical Guide for the UK and Ireland, Green Books (2009).
© Woodhead Publishing Limited, 2010
10
Polymeric foam materials for insulation in buildings D. F e l d m a n, Concordia University, Canada
Abstract: This chapter discusses polymeric foams used mainly for building insulation with a view to saving energy. It deals first with a brief foam history, the necessary materials for foam production, the polymers and the foaming (blowing) agents, and the foaming mechanism. It continues with the type of processing polymers for foam production and underlines the thermoplastic and thermosetting foams manufactured for the construction industry. It ends with foam main properties and future trends in the field of polymeric insulation materials. Key words: polymers, foam processing, thermoplastics and thermosettings, properties, future trends.
10.1
Introduction
Synthetic polymers are the raw materials used to produce plastics, synthetic fibers, elastomers, adhesives, sealants, etc. They are also important in the foam industry. Polymer foams that are used mainly for thermal and acoustical insulation of buildings are also known as cellular polymers or cellular plastics; they are multiphase material systems (composites) that consist of a polymer matrix and a fluid phase which is usually a gas. Thermal insulation has and will have a major role in energy savings in buildings. The history of the science and technology of synthetic foams can be traced from the late 1920s with the latex foam. In the 1930s phenol-formaldehyde and urea-formaldehyde (1933) foams were developed. The first patents for cellular polystyrene (PS) were obtained in Sweden (1931) and the USA (1935). The rigid polyurethane (PU) foams were developed in Germany during the early 1940s. Polyisocyanurate (PIR) (1966), polyethylene (PE), poly(vinyl chloride) PVC, polycarbonate (PC), polyethylene terephthalate (PET), ABS (acrylonitrile–butadiene–styrene) terpolymer, modified polyphenilene oxide and polyimide were produced later. Polymer foams have entered the construction industry as a direct replacement of conventional thermal insulating materials such as asbestos, glass fiber, mineral fiber, cellulosic fiber, perlite, vermiculite, etc. If necessary, some foams can contain additional reinforcement, such as fiber reinforced ones, or syntactic foams that have glass, ceramic or polymer microspheres. The 257 © Woodhead Publishing Limited, 2010
258
Materials for energy efficiency and thermal comfort in buildings
US market in 2006 was more than 4 million tons for polymer foams; PU occupies the largest market share (53%) in terms of amount utilised, while PS is the second (26%) (Lee et al., 2005).
10.2
Foams classification, materials and foaming mechanism
Foams are made of thermoplastic or thermosetting polymers. They have been classified following different criteria such as: ∑
The kind of polymer from which the matrix is made (PU, PS, PVC, etc.). ∑ Cellular morphology (open or closed cells). The two morphologies can coexist so that a polymer foam is not always completely open or closed cell. From the point of view of the cell size polymer foams are classified as macrocellular (>100 mm), microcellular (1–100 mm), ultramicrocellular (0.1–1 mm) or nanocellular (0.1–100 nm) (Lee et al., 2005). The microcellular structure can be achieved by rapid depressurization of the polymer–blowing agent system, to allow the cells nucleation and growth as in the batch process after saturating the polymer with blowing agents (Zhang et al., 2007). ∑ Mechanical behavior (flexible or rigid); the rigid foams can be subdivided into non-structural, applied as thermal insulation, or structural which require high stiffness, strength and impact resistance. ∑ Density: low (10–30 kg/m3); medium (50–350 kg/m3), high (350–900 kg/m3).
10.2.1 Blowing agents Physical or chemical blowing agents are used in the manufacture of foams. The physical ones are compressed gases and volatile liquids such as N2, CO2, hydrocarbons, ketones and alcohols. The chemical ones are generally solid organic or minerals which decompose in a certain temperature range. A pressure-quench technique is used to obtain foams by using supercritical CO2 (scCO2) (Goel and Beckman, 1994). N2, air, CO2 or a mixture of air and helium are examples of gaseous blowing agents. Among these N2 and air are preferred since they are inert, non-toxic, non-flammable and have a low diffusivity with respect to the majority of polymers. Although N2 can be used as a blowing agent in the polymer foaming process, most publications on this topic address the foaming of polymers using CO2 because this also affects some polymer properties thereby enhancing polymer processability (Michaeli & Heinz, 2002). However, both N2 and CO2 are considered to be sustainable alternatives for the replacement
© Woodhead Publishing Limited, 2010
Polymeric foam materials for insulation in buildings
259
of the currently used blowing agents (Jacobs et al., 2008). The foaming of PS and cellulose acetate, for instance, has been studied using a technique based on the saturation of the polymer by scCO2 and rapid decompression. The diameter of the resulting microcellular structures has been controlled manipulating the process parameters (Reverchon and Cardea, 2007). Volatile liquids with boiling points below 110 °C like aliphatic hydrocarbons (C5–C7) are useful physical blowing agents. Ideal agents are the halogenated aliphatic hydrocarbons which, in addition to the above-mentioned characteristics, have a very low thermal conductivity. However, increases in chlorofluorocarbon (CFC) concentrations in the upper atmosphere would lead to long-term damage to the ozone layer. Global attention drawn to this led to the signing of the Montreal protocol in 1987. CFCs will be banned by 2010 according to this protocol. Recent measurements of the atmospheric chlorine content indicate that the equivalent effective chlorine content in the northern troposphere has been decreasing. In the rigid foam applications the alternative blowing agents are hydrochlorofluorocarbons (HCFC) with low ozone depletion potential (ODP), hydrofluorocarbons (HFC) and hydrocarbons with zero ODP. Comparing the ODP of CFC-11 (CFCl3) or CFC-12 (CF2Cl2) having ODP = 1.0 with HCFC123 (CF3CHCl2) which has 0.02–0.06 ODP and HCFC-124 (CF3CHClF) with ODP = 0.02–0.04, it is clear why the former are being replaced (Vachon, 2001). Blending small quantities of CO2 with HFC-245fa turned out to be beneficial for foaming and decreased the foam density further than using HFC-245fa alone (Vachon, 2005). The development of the next generation (zero ODP) blowing agents has been underway for several years (Wu et al., 1999; Bogdan et al., 1999; Zipfel et al., 1999; Andrady, 2003). The most important chemical blowing agents are ammonium bicarbonate (decomposition temperature 60 °C), sodium bicarbonate (decomposition temperature interval 100–140 °C), and sodium borohydrate (decomposition temperature 300 °C). Water, in some cases, can be also used as a blowing agent (Niyogi et al., 1999; Rizvi et al., 2000). Most of the known organic blowing agents belong to: azo and diazo compounds, N-nitroso compounds, sulfonylhydrazides, azides, triazines, triazols, tetrazols, sulfonyl semicarbazides, urea derivatives, guanidine derivatives and esters (Shutov, 1991; Seymour, 1991).
10.2.2 Foaming mechanism The foaming mechanism and the process of cellular structure formation can be mechanical, physical or chemical. In the first case the bubbles are created by stirring a gas into the mass of matrix components or by forcing the gas into the melted polymer matrix. In the physical process, known as nucleation, heating produces the evaporation of a low boiling liquid, thus forming the
© Woodhead Publishing Limited, 2010
260
Materials for energy efficiency and thermal comfort in buildings
bubbles. In chemical foaming, the blowing agent reacts under the influence of heat, releasing a gas, which forms the voids in the melted polymer beads obtained through suspension polymerization (Michaeli et al., 1992). The blowing agent expands the molten polymer initiating cells that produce the foam. The main requirements for the blowing agent are the amount, solubility and diffusivity (Rosato, 1997). The stability of the foam is conditioned by the solubility and diffusivity of the gas in the matrix. The growth of the cell depends on the pressure difference across the cell membrane between the inside of the cell and the surrounding medium. Such pressure differences can be generated by lowering the external pressure (decompression) or by increasing the internal pressure in the cells (pressure generation). The cells that grow produce the foam. A complete dissolution of the blowing agent in the polymer is essential for producing foams with uniform cells. An incomplete dissolution leads to heterogeneous structure and surface defects. Processing aspects of some polymers like PS were correlated to off-line solubility and diffusivity of HFC-134a (Gedron et al., 2002). New phase formation known as nucleation can originate from the selfstructural adjustment or from ‘foreign’ seeds known as nucleants or nucleation agents. The bubbles are said to form by a nucleation process (Saunders and Klempner, 2004). Foaming basically involves bubble nucleation and bubble growth (phase separation) to make a foamed product that can be defined as visible gas cells dispersed in a denser continuum matrix (Lee, 2000). Foam nucleation, foam growth and cell coalescence are the three major events in the foaming process. Almost all foam technologies use nucleating agents in one form or another. The main role of a nucleant is to provide surfaces on which bubbles can organize and grow. There are two types of nucleants. Passive nucleants (mineral or organic) provide nucleating microvoids around which microbubbles can form. In addition to sites for bubble nucleation, active nucleants provide blowing gas to promote microbubble formation (Throne, 2004). The required amount of nucleating agent is determined by the polymer melt viscosity and the foaming technique and varies between 0.05 and 1%. The bubble growth is influenced by the concentration-dependent blowing agent diffusion coefficient, the transient cooling of the expanding polymer, the influence of the blowing agent on its viscosity and the escape of the blowing agent from the surface of the foam (Ramesh, 2000, Lee et al., 2007). The presence of sufficient blowing agent is very important to support efficient cell growth, and a certain solubility is necessary to achieve low foam density. Both solubility and diffusivity of the blowing agent in the melted matrix are key parameters in foam processing because they are the limiting factors in determining the density and also in regulating the phase separation dynamics during bubble growth (Talibouet, 2005). Diffusivity affects nucleation and bubble growth. It depends on several
© Woodhead Publishing Limited, 2010
Polymeric foam materials for insulation in buildings
261
factors including molecular size and the solubility of the diffusing gas in the polymer. The diffusion constants for CO2, O2 and N2 are higher than that of CFCl3 (Backus, 1991). A high diffusivity favors a rapid nucleation and fine cell structure formation. Smaller molecular blowing agents such as CO2 are more suited to generating foams with high cell density and high foam density, while fluorocarbons and hydrocarbons having larger molecules are convenient for the production of low-density foams. (Nawaby and Zhang, 2005). Initially, cells of fresh foams contain the higher amount of blowing agent and the lower amount of air components. During the service life, the cell gas composition changes because of air ingress, solubility of the blowing agent in the polymer and loss of it to the environment. Ultimately (during ageing) most the blowing agent is replaced by air and the foam insulating efficiency attains its final steady level (Bomberg and Kumaran, 1995). The presence of nanoclays led to foams with different thermal and rheological properties that affect nucleation process and growth phenomena of gas bubbles. X-ray diffraction was performed to evaluate the dispersion of the silicate layers in the poly–e-caprolactam matrix. Rheological tests were performed in shear at 80 °C in order to analyse the effect of composition on the complex viscosity and their elastic and dissipative components (Iannace et al., 2003). The PS/1% Montmorillonite-layered silicate (MLS) nanocomposites universally exhibited Tg values about 15 °C lower than those of pure PS. This suggests that the dispersion of the MLS in the PS at this concentration locally disturbed the entanglements of the macromolecules enough to ease the material to soften at lower temperature. The DSC endothermic peak was not affected by the presence of MLS (Strauss and D’Souza, 2004). The nanoparticles can significantly increase the melt viscosity (Lee et al., 2005). The role of melt viscosity in the nucleation process was explored (Feng and Bertelo, 2004). Rheological studies on uniaxial elongation flow were conducted for PP clay nanocomposites with higher amounts of clay; this was about one order higher in magnitude that that of PP with lower amounts of clay (Nam et al., 2002). The extremely fine dimensions and large surface area of nanoparticles provide much more intimate contact between the particles, polymer matrix and gas. Furthermore, a significantly higher effective particle concentration can be achieved at a low nominal particle concentration. Both could lead to improved nucleation efficiency. The effect of particle concentration on foam nucleation was investigated for different polymer foams. The surface chemistry of clay nanoparticles not only affects the particle dispersion but also has a tremendous effect on the nucleation efficiency in a polymer-clay-blowing agent system. Some modified nanoclays can covalently bond polymers like PS or poly(methyl methacrylate) on the clay surface via in situ polymerization (Lee et al., 2005). Light scattering and high speed X-ray scattering have been used for studying the nucleation and bubble growth (Francis et al., 2006). Scanning electron
© Woodhead Publishing Limited, 2010
262
Materials for energy efficiency and thermal comfort in buildings
microscopy application in the case of PP/clay nanocomposites confirmed the formation of high cell density and cell sizes in the range of 30–120 mm. On the other hand transmission electron microscopy for the same system showed biaxial flow-induced alignment of clay particles along the cell boundary (Nam et al., 2002). The formation of nuclei in a viscous liquid followed by cell growth is a very complex mechanism, which is influenced by many parameters, such as temperature, viscosity, blowing agent concentration, depressurization rate and pressure drop. Despite significant research efforts, it will probably take a considerable time before the complete process is fully understood (Jacobs et al., 2008).
10.3
Processing technologies
The performance of the foam depends to a great extent on the type of base polymer, the type of blowing agent and the means of processing. Depending on the type of processing there are various combinations of polymer-blowing agent. As previously mentioned the last one expands in the melted polymer initiating cells that grow to produce the foam. Polymer foams are produced batch-wise or continuously. The principal processes are extrusion, injection molding and compression molding (Rosato, 1997). Thermoplastic foams are frequently obtained by extrusion. Extrusion and injection molding can be used to turn a great variety of thermoplastic polymers in foams. However, the production of thermosetting foams like PU can be controlled because the polymer can exhibit a great variety of states and properties.
10.3.1 Batch process Most commercial moldable foam bead items are produced by a batch process using a volatile organic blowing agent. In the case of polyolefin foam manufacturing, the polymer pellets are impregnated with the blowing agent in an autoclave. Expansion is accomplished either by an abrupt discharge of the beads into the atmosphere or by heating the beads with steam (Park, 1991). In a batch process foams are produced by charging a polymer in a pressure vessel (autoclave) with the blowing agent, usually N2 or CO2, at constant pressure until a sorption equilibrium is reached. The polymer can be expanded then either by rapid decompression of a heated pressure vessel or by submitting the solid saturated material to a higher temperature environment (Vachon, 2005). Foaming of PC has been carried out mainly using the batch process at lower temperature than in the case of extrusion. As a result the foams’, properties are different, for instance the relaxation time is longer (Gedron, 2005). Using this process an intercalated PC/clay foam nanocomposite having
© Woodhead Publishing Limited, 2010
Polymeric foam materials for insulation in buildings
263
different amounts of clay has been obtained using scCO2 as a blowing agent (Ito et al., 2006). The foam batch processing of neat polylactide (PLA) and two different types of PLA-based nanocomposites was carried out using scCO2 as a foaming agent (Yu et al., 2006). Polyurethane/montmorillonite nanocomposites were obtained with organically modified layered silicates (organoclays) by in situ polymerization and foams were prepared by a batch process. The presence of clay results in an increase in cell density and a reduction of cell size compared to pure polyurethane foam (Cao et al., 2005).
10.3.2 Extrusion The vast majority of thermoplastic rigid foams for construction insulation are produced by extrusion that permits the fabrication of sheets and blocks of varying cross-sections. The primary purpose of the extruder is to take room-temperature polymer resin in the form of pellets, beads or powders and convert the resin to a molten plastic at sufficiently high pressure to allow the high viscous melt to be forced through a nozzle into a mold in the case of injection-type processes, or through a die in the case of blow molding or continuous extrusion. This process involves several steps: dissolution of the blowing agent, the melting (plasticization) of the polymer, the nucleation of the bubbles upon pressure release, their growth, and cell stabilization. The gas that is formed by a decomposition reaction of the chemical blowing agent dissolves in the polymer melt because of the pressure level in the extruder. When leaving the die the pressure drops to atmospheric level, the melt becomes oversaturated with gas and bubbles are formed (Wahlen, 2006). The operating conditions are pressure, temperature and shear rate. If they are not adequate for the selected blowing agent, premature foaming occurs and a poor quality foam is produced. In the extrusion process for producing a cellular foam, such as PS, a solution of the blowing agent is introduced in the molten polymer (formed in an extruder under pressure); this is forced through an orifice onto a moving belt at ambient temperature and pressure. The polymer simultaneously expands and cools under conditions that give enough strength to maintain dimensional stability at the time corresponding to optimum expansion. The cooling of the polymer to a temperature below its glass transition temperature (Tg) provides its stabilization. Cooling is effected by vaporization of the blowing agent, gas expansion and heat loss to the environment. In the case of PS processing, this technology leads to foams having a density in the range of 27–53 kg/ m3 and even higher (Suh, 1991). The basic extrusion processing techniques utilize one of: ∑
a single screw with large diameter extruder
© Woodhead Publishing Limited, 2010
264
Materials for energy efficiency and thermal comfort in buildings
∑ twin screw extruder ∑ a single screw extruder with a cooling system ∑ two extruders in tandem. Of the four, the last process is the most successful and widely used. The first extruder is used for melting, mixing, gas injection (usually N2) and feeding the extrudate to the secondary extruder. This is used for cooling and additional mixing before it exits a circular or annular die, where the foaming action is initiated. The secondary extruder is set up to ensure a uniform temperature before the exit of the melt, thus a uniform cell structure is obtained (Rosato, 1997). The shaping die is attached to the exit of the second extruder (Throne, 2004). A proper die design plays a crucial role in improving the quality of the foams, since the geometry of the die determines the pressure decay rate and absolute pressure drop, by which both cell density and cell morphology are dominantly affected. In some manufacturing processes a preliminary partial gazeification of the polymer beads is applied. The processing techniques used for rigid PU foams for insulation can also be used for PIR, including laminate processing, pour-in-place processing and spray processing (Ashida, 1991). The largest volume of rigid PU foams is produced in sheet form on machines known as laminates that are essentially double conveyors, between which foam rises to a controlled thickness. The coated sheet products obtained on laminators are widely used for construction applications as roofing or facing for frame construction (Backus, 1991). Studies done on LDPE extrusion with different nucleating agents and pressure profiles show the importance of high pressure gradients on the homogeneity of celled foams (Walter and Robert, 2002).
10.3.3 Injection molding This kind of processing uses screw preplasticizing injection molding equipment capable of supplying blowing agent, plasticity, kneading and maintaining retention time for gas/polymer solution. Some main parameters like injection velocity, molding temperature, retention time, plunger stroke and dwelling pressure were studied in the case of microcellular PS. It was found that cell size decreases and cell density increases with an increase in injection velocity. Cell size decreases about linearly with an increase in velocity and becomes about half size for 5 times of velocity (Hidetaka and Minoru, 2003). The molding time depends on the type of polymer as well as on the size and shape of the foam item. The two major molding techniques used in the PU industry are the hot cure and the cold cure (or high resiliency) processes. The latter uses high reactive components (polyols) so that less curing (energy) is needed (Bicerno et al., 2004).
© Woodhead Publishing Limited, 2010
Polymeric foam materials for insulation in buildings
265
A new foam molding technology is able to generate single-phase polymer/ blowing agent solutions and is therefore capable of producing parts with smaller cell sizes, and more uniform cell size distributions (Xu et al., 2008). Foams can also be obtained by a casting and leaching technique which consists of dissolving the polymer in a highly volatile solvent and casting the solution in a mold containing a solid porogen (NaCl, KCl). After the solvent evaporation, the foam is washed with water to eliminate the salt. The technique has the advantage of controlling the morphology and pore size. An injection molded foam consists of compact skin layers and a cellular core; the former dominate the mechanical behavior. The thicker the skin layers the higher the mechanical values. For injection-molded foams, weight, tensile strength, flexural strength and stiffness decrease with increasing of the main process parameters such as melt temperature, mold temperature and injection velocity, whereas they increase with increasing back pressure (Chien et al., 2004). The mold temperature can affect the foam surface (skin) degradation. A recent study presents some possibilities to control the morphology of structural foams by an intelligent mold and process design. Parameters affecting the morphology of the foam like temperature, cavity pressure and the expansion ratio were varied. Structural properties of the foam like surface finish, overall density and skin layer thickness as well as mechanical properties have been examined (Spoerrer and Alstaedt, 2007). Other researchers (Guo et al., 2007) found that the cell structure (cell density and dimension), an important aspect of morphology, could be improved greatly by optimizing key parameters such as shot size, blowing agent amount, back pressure, injection speed and melt temperature.
10.4
Thermoplastic and thermosetting foams
The most used thermoplastic foams are made of polymers like PS, PVC, PE, PP, ABS, PET, cellulose acetate. Among these the construction industry uses mostly the first two. Rigid closed cell PS for the construction industry with densities between 16 and 180 kg/m3 are obtained at around 120 °C from expandable PS beads (produced by suspension polymerization). Extrusion, which takes place at up to 260 °C, leads to the production of PS foams with densities 16–80 kg/m3. The extruded foam has a more regular structure than the molded one, better strength and higher water resistance. PS foam is affected by temperatures close to its Tg, i.e. in the range of 71–77 °C. In the construction industry, PS foams are used mainly for perimeter insulation, roof deck insulation and masonry wall insulation (Feldman, 2005). PVC can be foamed through free expansion or constrained, known as the Celuka process (Patterson, 2002), with or without plasticizer for achieving flexible or rigid characteristics.
© Woodhead Publishing Limited, 2010
266
Materials for energy efficiency and thermal comfort in buildings
Some of the best advantages of PVC rigid foams are: low volume cost, good mechanical properties (high tensile, compressive and shear strength), good chemical and weather stability, low thermal conductivity, low water permeability, resistance to termite and bacterial growth, good fire resistance and they do not crumble under impact or vibration (Feldman, 2005). Rigid PU foam is widely applied for thermal insulation purposes in the building and construction industry where it is available as foam board, sandwich panels, sprays, aerosol cans and shaped and molded foams. For their manufacture, PIR technology is frequently applied in addition to PU technology. Both PU and PIR construction foams are characterized by their excellent thermal conductivity with l between 20 and 30 mW/mK, low densities ranging from 30 to 100 kg/m3 at high mechanical strengths of 10–100 kPa. They can be used over a temperature range from –80 to +100 °C. The very low thermal conductivity enables application of thinner panels when space filling is an issue. Spray PU foams combine thermal insulation, filling, mechanical strength and adhesion in a very cost-effective way. Foam panels of up to 20 cm thickness are produced continuously at a double band laminator. Depending on the type of faces (films, paper, aluminum foil, wood) on the panel, we can distinguish flexible-faced or rigid-faced foam panels (Grunbauer et al., 2004).
10.4.1 Properties Density The properties of polymer foams are strongly related to their density or, in other terms, to the relative amounts of the polymer and gas phases. Many properties (E) are related to density (r) by a power function of general form
E = Krn
10.1
where constant n is normally in the range 1 to 2, and K is related to both polymer characteristics and temperature (Backus, 1991). Some density values of polymer foam are: ∑ ∑ ∑ ∑
PS extruded plank 35–53 kg/m3 (Suh, 1991) PS expanded plank 16–80 kg/m3 (Suh, 1991) PS extruded sheet 96–180 kg/m3 (Suh, 1991) PE extruded sheet 27–40 kg/m3 (Park, 1991).
Thermal conductivity Thermal conductivity l of polymer foams is the sum of the thermal conductivities of the solid phase, lp, and of the gas, lg, convective, lc, and radiative, lr components:
© Woodhead Publishing Limited, 2010
Polymeric foam materials for insulation in buildings
l = l p + l g + l c + l r
267
10.2
In the construction industry, K factor term is preferred instead of thermal conductivity. One of the main requirements of insulating materials is a low thermal conductivity. Here are some examples of the values of this characteristic for polymer foams used in the construction industry. ∑ ∑ ∑ ∑ ∑ ∑
Rigid PU foam 0.014–0.016 W/mK (Backus, 2004) PIR rigid foam 0.018–0.020 W/mK (Ashida, 1991) PS extruded plank 0.030 W/mK (Suh, 1991) PS expanded plank 0.035–0.037 W/mK (Suh, 1991) PS extruded sheet 0.035 W/mK (Suh, 1991) PE extruded plank 0.056–0.089 W/mK (Park, 1991)
Some studies demonstrate the ability to calculate thermal conductivity and elastic properties on three-dimensional images of industrial polymer foams. Obtained data are well defined over a broad range of phase fractions by structure–property correlation which differ from common theoretical and recently derived empirical bounds. Results for thermal conductivity and elasticity show little scatter and provide the basis for accurate empirical correlation between phase fraction and properties. They highlight an exciting potential to predict physical properties from images of complex materials and the future development of more accurate correlations between structure and mechanical/transport properties for microstructures (Saadatfar et al., 2004). Thermal conductivity is a time-independent physical property. The rate at which heat is transferred through foam is governed by thermal diffusivity a which is a time-dependent physical property with units m2/s. Thermal diffusivity is the ratio of thermal conductivity to the product of density and heat capacity. For high density foams, thermal diffusivity is nearly independent of foam density. For low density foams, thermal diffusivity increases nearly linearly with decreasing foam density (Throne, 2004). Mechanical properties Mechanical properties of the foams are poor. Any factor affecting melt rheology can influence cell formation during processing and hence the properties of the final foam. An important problem with polymer foams used as insulating materials is the decrease of mechanical strength with the increase of the size of the cells. The solution is the nanocomposite foams that contain nanoparticles. Additives such as montmorillonite, carbon nanofibers, spherical silica particles, polyhedral oligomeric silsequioxane nanocrystals (McCabe and Nutt, 2002), etc. (Jacobs et al., 2008) have been experimented with. Foams with hectorite nanoparticles exhibit improved thermal stability and mechanical properties when compared with neat polymer foams (Velasco et al., 2007).
© Woodhead Publishing Limited, 2010
268
Materials for energy efficiency and thermal comfort in buildings
PS has a higher flexural strength in comparison with other thermoplastics. This indicates that at the same density it demonstrates a better rigidity. This characteristic, coupled with a fine cell structure, is ideal for thermal insulation application. For production control the average MW of PVC can be calculated from the Mark–Houvink–Sakurada equation expressed in terms of the Fikentscher K value or viscosity number. Commercially available PVC grades are supplied in Europe with K values ranging from 50–80. Increasing the MW of PVC polymer improves the mechanical properties of the foam by upgrading the solid material of cellular walls. The effect is greatest in rigid foams and at high densities. It is possible to produce rigid PVC foam with exceptional strength through a cross-linking reaction with maleic anhydride, isocyanate and a catalyst. The ingress of water and mainly of sea water and its damaging effects on polymeric foams were investigated and explained by a mechanics model. It has been shown that exposure to sea water damages the structure of cellular foams and degrades the delamination fracture toughness at the core/facing interfaces of sandwich layups. However, those detrimental effects are confined to the outer layers of the foams and the near vicinity of crack tips (Weitsman et al., 2005, Suh, 2004). A recent published review provides the current state of polymer foams biodegradation (Gautam et al., 2007). Flammability The acceptance of polymer foams in the construction industry led to the need to produce materials of low combustibility with a low smoke evolution during fires. Their low thermal inertia permits the surface to respond rapidly to any imposed heat flux and consequently to ignition. Addition of flame retardants is the most common route to improve the non-flammable behavior of foams. In commercial use are flame retardants based on phosphorus, halogen, mixture of halogen compounds, antimony oxide, N2 and boron compounds, alkali metal salts, and hydrates of metal oxides. PS foam can produce molten drops (especially in ceiling application) and in some cases these drips burn. However, the presence of bromine-containing flame retardant is able to delay the ignition of molten PS. In large fires PS foam burns with the generation of a dense smoke. If the foam is behind plaster or concrete facing, the extent of burning is usually limited to a small area near the original site of the fire (Irvine et al., 2000). PU foams do not melt in fire but burn to produce pyrolysis gases, dense smoke and some char. The rate of the burning depends on the type and amount of fire retardant present in the foam (Feldman, 2005). From the point of view of combustion, PIR is superior to PU. PIR behaves similarly to fire retardant PU foam in the early stages of a fire, but the char
© Woodhead Publishing Limited, 2010
Polymeric foam materials for insulation in buildings
269
formation significantly restricts the spread of the fire. Recognition of the efficient fire barrier characteristics of glass fiber reinforced PIR foam chars has allowed new PIR formulations, even some without flame retardant. Such composites generate less smoke than PIR foam (Feldman, 2005). Technologies for manufacturing PU foams led to the use of reactive flame retardants able to provide a permanent effect. Polyols, isocyanates containing phosphorus, halogens (usually bromine) or both are the most used (Troitzsch, 1990).
10.5
Future trends
Future foam applications may emphasize structural characteristics with a limiting of application requiring primarily thermal insulation. Consideration of their full range of properties should lead to a greater variety of use. Novel nano-composite foams based on the combination of functional nano-particles and supercritical fluid foaming technology can lead to a new class of materials that are lightweight, have high strength, good barrier properties, improved dimensional and thermal stability, whilst maintaining the same thermal conductivity as PIR. For foam products, various desirable cell morphologies (e.g., small vs. large cells, open vs. closed cells) must be attainable through successful control of nucleation and growth of bubbles.
10.6
Sources of further information and advice
Gibson LJ and Ashley MF (1997), Cellular solids; structure and properties, 2nd edn, Cambridge, Cambridge University Press. Randall D and Lee S, eds. (2002), The polyurethanes book, New York, John Wiley. Mils NJ (2005), Plastics; microstructure and engineering applications, 3rd edn, London, Butterworth Heinemann. Eaves D (2004), Handbook of polymer foams, Shrewsbury, Rapra Technology Ltd. Muller N and Ehrenstein GW (2004), ‘Evaluation and modeling of injectionmolded rigid polypropylene integral foam’, J. Cell Plast. 40, 45–59. Rachtanapun P, Selke SE and Matuana LM (2004), ‘Relationship between cell morphology and impact strength of microcellular foamed high-density polyethylene/polypropylene blends’, Polym. Eng. Sci. 44, 1551–1560.
10.7
References
Andrady AL (2003), Plastics and environment, Hoboken, Wiley. Ashida K (1991), ‘Polyisocyanurate foams’, in Klempner D and Frisch KC, Polymer foams, Munich, Hanser, 91–131. © Woodhead Publishing Limited, 2010
270
Materials for energy efficiency and thermal comfort in buildings
Backus JK (1991), ‘Rigid polyurethane foams’, in Klempner D and Frisch KC, Polymer foams, Munich, Hanser, 74–93. Backus JK (2004), ‘Rigid polyurethane foams’, in Klempner D and Sendijarevic V, Polymeric foams and foams technology, 2nd edn, Munich, Hanser, 121–140. Bicerno J, Dawssin RD, Elwell MJA, van der Wal HR, Berthevas P, Brown M, Casati F, Farrissey W, Fosnaugh J, de Genova R, Herrington R, Hicks J, Hinze K, Hock K, Hunter D, Jeng L, Laycock D, Lidy W, Mispreuve H, Moore R, Nafziger L, Norton M, Parrish D, Priester R, Skaggs K, Stahler L, Sweet F, Thomas R, Turner G, Wiltz G, Woods T, Christenson CP and Schrock AK (2004), ‘Flexible polyurethane foams’ in Lee ST and Ramesh NS, Polymeric foams, Boca Raton, FL, CRC Press, 173–253. Bogdan MC, Parker RC and Williams DJ (1999), ‘Utilization of HFC–245fa in the construction industry’, J. Cell Plast, 35, 11. Bomberg M and Kumaran M (1995), ‘Procedures to predict long term thermal performance of boardstock foam insulations’, International report No. 694NRC-CNRC, National research Council of Canada, Ottawa, Ontario, Canada. Cao X, Lee LJ, Widya T and Mocosko C (2005), ‘Polyurethane/clay nanocomposites foams; processing, structure and properties’, Polymer, 46, 775–783. Chien RD, Chien SC, Lee PH and Huand JS (2004), ‘Study on the molding characteristics and mechanical properties of injection-molded foaming polypropylene parts’, J. Reinf. Plast. Comp., 23, 429–444. Feldman D (2005), ‘Plastics and polymer composites’ in Akovali G, Polymers in construction, Shrewsbury, Rapra Technologies Ltd., 237–301. Feng JJ and Bertelo CA (2004), ‘Prediction of bubble growth and size distribution in polymer foaming based on a new heterogeneous nucleation model’, J. Rheol. 48, 439. Francis TJ, Wassner E, Rieger J, Moreira A, Schiler P and Lopez P (2006), ‘Time resolve bubble nucleation in polymer foams’, Blowing agents and foaming processes 2006, 8th International Conference Munich, May 16–17 2006 P22/1–P22/8, Shrewsbury, Rapra Technology Ltd. Gautam R, Bassi AS and Yanful EK (2007), ‘A review of biodegradation of synthetic plastic and foams’, Appl. Biochem. and Biotechnol., 141, 85–108. Gedron R (2005), ‘Rheological behavior relevant to extrusion foaming’, in Gedron R (ed.), Thermoplastic foam processing, Boca Raton, FL, CRC Press, 43–104. Gedron R, Huneault M, Tatibouet J and Vachon C (2002), ‘Foam extrusion of PS blown with HFC-134a’, 4th International Conference proceedings: Blowing agents and foaming processes, Heidelberg, Germany, May 27–28, Shrewsbury, Rapra Technology Ltd, 97–111. Goel SK and Beckman E (1994), ‘Generation of microcellular polymeric foams using supercritical carbon dioxide. I: effect of pressure and temperature on nucleation’, J. Polym. Eng. Sci., 34, 1137. Grunbauer HJM, Bicerano J, Clavel P, Daussin RD, de Vos HA, Elwell MJ, Kawabata H, Kramer H, Latham DD, Martin CA, Moore SE, Obi BC, Parenti V, Schrock AK and van den Bosh R (2004), ‘Rigid polyurethane foams’, in Lee ST and Ramesh NS, Polymeric foams, Boca Raton, FL, CRC Press, 253–311. Guo MC, Heuzey MC and Carreau PJ (2007), ‘Cell structure and dynamic properties of injection molded polypropylene foams’, J. Polym. Eng. Sci., 47, 1070–1081. Hidetaka K and Minoru S (2003), ‘Effect of key process variables on microstructure of injection molded microcellular polystyrene foam’, Cell Polym., 22, 175–190.
© Woodhead Publishing Limited, 2010
Polymeric foam materials for insulation in buildings
271
Iannace S, Dimaio E, Di YW, Mensitieri G and Nicolais L (2003), ‘The foaming process of biodegradable polyesters’, Proceedings of the 7th World conference on biodegradable polymers and plastics, Terrenia, Italy, June 4–8, 2002, 273–287. Irvine DJ, McCluskey JA and Robinson IM (2000), ‘Fire hazard and some common polymers’, Polym. Degrd. Stab., 67, 383–396. Ito Y, Yamashita M and Okamoto M (2006), ‘Foam processing and cellular structure of polycarbonate based nanocomposites’, Macromol. Mat. Eng., 29, 773–783. Jacobs LJM, Kemmere MF and Keurentjes JTF (2008), ‘Sustainable polymer foaming using high pressure carbon dioxide; a review on fundamentals, processes and applications’, Green Chem, 10, 731–738. Lee LJ, Zeng C, CaoX, Han X, Shen J and Xu G (2005), ‘Polymer nanocomposite foams’, Compos. Sci. Technol., 65, 2344–2363. Lee ST (2000), ‘Foam nucleation gas-dispersed polymeric system’, in Lee ST (ed.), Foam extrusion, Lancaster, PA, Technomic, 81–121. Lee ST, Park CB and Ramesh NS (2007) Polymeric foams, Boca Raton, Fl, CRC Press. McCabe B and Nutt S (2002), ‘Nanocomposite polyurethane foams via POSS blends’, Mat. Res. Soc. Symp. Proc., 733E, T1.6.1–T1.6.5. Michaeli W and Heinz R (2002), ‘Extrusion of thermoplastic foams with CO2 as a blowing agent’, 4th International Conference proceedings Blowing agents and foaming processes, Heidelberg, Germany, May 27–28, Shrewsbury, Rapra Technology Ltd, 19–26. Michaeli W, Grief H, Kaufman H and Vossenburger FJ (1992), Training in plastic technology, Munich, Hanser. Nam PH, Maiti P, Okamoto M and Kotaka T (2002), ‘Foam processing and cellular structure of polypropylene/clay nanocomposites’, Polym. Eng. Sci., 42, 1907–1918. Nawaby A and Zhang Z (2005), ‘Solubility and diffusivity in thermoplastics’, in Gedron R, Thermoplastic foam processing, Boca Raton, FL, CRC Press, 1–42. Niyogi D, Kumar R and Gandhi KS (1999), ‘Water blown free rise polyurethane foams’, Polym. Eng. Sci., 39, 199–209. Park CP (1991), ‘Polyolefin foams’, in Klempner D and Frisch KC, Polymeric foams, Munich, Hanser, 188–228. Patterson J (2002), ‘Vinyl foam technology’, 62nd SPE ANTEC preprints, 3304–3308. Ramesh NS (2000), ‘Foam growth in polymers’, in Lee ST, Foam extrusion, Lancaster, PA, Technomic, 125–143. Reverchon E and Cardea S (2007), ‘Production of controlled polymeric foams by supercritical CO2’, J. Supercrit. fluids, 40, 144–152. Rizvi G, Matuana L and Park CB (2000), ‘Foaming of PS/wood fiber composites using moisture as a blowing agent’, Polym. Eng. Sci., 40, 2124–2132. Rosato D (1997), Plastics processing data handbook, 2nd edn, London, Chapman and Hall. Saadatfar M, Knackstadt M, Arns CH, Sakellariou A, Senden TJ, Sheppard AP, Sok RM, Steininger H and Schrof W (2004), ‘Polymeric foams properties derived from 3D images’, Physica A, 339, 131–136. Saunders JH and Klempner D (2004), ‘Fundamentals on foam formation’, in Klempner D and Sendijarevic V, Polymeric foams and foams technology, 2nd edn, Munich, Hanser, 5–15. Seymour RB (1991), Reinforced plastics; properties and applications, Materials Park, ASM International. Shutov FA (1991), ‘Blowing agents for polymer foams’, in Klempner D and Frisch KC, Polymeric foams, Munich, Hanser, 376–408. © Woodhead Publishing Limited, 2010
272
Materials for energy efficiency and thermal comfort in buildings
Spoerrer ANJ and Alstaedt V (2007), ‘Controlling morphology of injection molded structural foam by mold design and processing parameters, J. Cell. Plastics, 43, 313–330. Strauss W and D’Souza NA (2004), ‘Supercritical CO2 processed polystyrene nanocomposite foams’, J. Cell. Plastics, 40, 229–241. Suh KW (1991), ‘Polystyrene and structural foam’, in Klempner D and Frisch KC, Polymeric foams, Munich, Hanser, 91–131. Suh KW (2004), ‘Polystyrene and structural foam’, in Klempner D and Sendijarevic V, Polymeric foams and foam technology, 2nd edn, Munich, Hanser, 189–225. Talibouet J (2005), ‘Investigating foam processing’, in Gedron R, Thermoplastic foam processing, Boca Raton, FL, CRC Press, 195–234. Throne JL (2004), Thermoplastic foam extrusion, Munich, Hanser. Troitzsch J (1990), International plastics flammability handbook, 2nd edn, Munich, Hanser. Vachon C (2001), ‘Research on alternative blowing agents in thermoplastic foam processing’, in Gedron R, Thermoplastic foam processing, Boca Raton, FL, CRC Press, 141–194. Vachon C (2005), ‘Foaming polystyrene with HFC-245fa and blends of HFC-245fa and CO2’, 63rd Annual Technical Conference – Society of plastics Engineers, Washington, DC, Society of Plastics Engineers, 2572–2576. Velasco JL, Antunes M, Ayyad O, Saiz-Anoyo C, Rodriguez-Perez MA, Hidalgo F and Saja JA (2007), ‘Foams based on low density polyethylene/hectorite nanocomposites: thermal stability and thermo-mechanical properties’, J. Appl. Polym. Sci., 105, 1658–1667. Wahlen L (2006), ‘Blowing agents and foaming processes’, 8th International Conference, Munich, Germany, May 16–17, 2006, Shrewsbury, Rapra Technology Ltd, P2/1– P2/8. Walter M and Robert H (2002), ‘Extrusion of thermoplastics foams with CO2 as a blowing agent’, 4th International Conference proceedings: Blowing agents and foaming processes, Heidelberg, Germany, May 27–28, 2002, Shrewsbury, Rapra Technology Ltd, 19–26. Weitsman YJ, Li X and Ionita A (2005), ‘Sea water effects on polymeric foams and their sandwich layups’, Proceedings of the 7th International conference on sandwich structures, Aalborg, Denmark, Aug. 29–31, 193–197. Wu J, Albony A and Morton D (1999), ‘Evaluation of the next generation HFC blowing agents in rigid polyurethane foams’, J. Cell Plast., 35, 421. Xu X, Park CB, Lee JWS and Zhu X (2008), ‘Advanced structural foam molding using polymer/gas melt flow stream’, J. Appl. Polym. Sci., 109, 2855–2861. Yu E, Manabu I and Masani, O (2006), ‘Foam processing and cellular structure of polylactide based nanocomposites’, Polymer, 47, 5350–5359. Zhang ZX, Zhang SL, Xim ZX and Kin JK (2007), ‘Polypropylene/waste ground rubber tire powder foams: a study of the relationship between processing and structure using supercritical carbon dioxide’, e-Polymers, 132, 1–12. Zipfel L, Barthelemy P and Dournel P (1999), ‘The next generation blowing agents from one single product to a product range’, J. Cell Plast., 35, 345.
10.8
Appendix: Abbreviations
ABS Acrylonitrile–butadiene–styrene terpolymer
© Woodhead Publishing Limited, 2010
Polymeric foam materials for insulation in buildings
CFC chlorofluorocarbon CO2 carbon dioxide HFC hydrofluorocarbons HCFC hydrochlorofluorocarbons K factor reflecting PVC molecular weight KCl potassium chloride MLS Montmorillonite-layer silicate MW molecular weight N 2 nitrogen NaCl sodium chloride ODP ozone depletion potential PE polyethylene PC polycarbonate PET polyethyleneterephthalate PIR polyisocyanurate PLA polylactide PS polystyrene PU polyurethane scCO2 supercritical carbon dioxide T g glass transition temperature a thermal diffusivity l thermal conductivity r density
© Woodhead Publishing Limited, 2010
273
11
Thermal insulation material for building equipment M. Z e i t l e r, FIW München, Germany
Abstract: This chapter discusses the characteristics of insulating materials and their usefulness as insulations for building equipment. The chapter first describes the bases of the heat transfer in insulating materials. Then the difference between the nominal values and the calculation values is discussed. All relevant standards for the characteristics and classifications for the insulating materials are pointed out. Key words: thermal conductivity of insulation materials, insulation system, fire behaviour, water vapour diffusion, attestation of conformity.
11.1
Introduction
Insulation materials need to have properties suitable for their application purpose. Insulation systems for industrial installations in technical building equipment need to cater for both the task of thermal as well as cold protection, and must occasionally even sustain changing temperatures. Insulation material manufacturers specify the area of applicability for their insulants as precisely as is needed and as generally as possible. To be able to guarantee an insulation system without deficiencies for a given application purpose, the thermal conductivity, the maximum service temperature and additionally, for employment in cold protection, the water vapour diffusion coefficient are considered the most important properties. Proof of behaviour in fires is compulsory. A possible release of dangerous substances, too, needs to be given proper attention. Insulation material properties are given as declared values by the manufacturer for the product as placed on the market. The declared thermal conductivity, which is an important determinant of market value, is also the starting point for heat protection calculations. Since the thermal conductivity of an insulant is temperature dependent and since it is susceptible to change through different influences dependent on the actual employment, the insulating quality of the system is determined through the so-called operational thermal This chapter is dedicated to Dr Walter F. Cammerer on the occasion of his 90th birthday.
274 © Woodhead Publishing Limited, 2010
Thermal insulation material for building equipment
275
conductivity in connection with the insulation layer thickness and depending upon the service boundary conditions. The basis for the calculation of thermal and cold protection is the design value of thermal conductivity, which must be greater than or at least equal to the operational thermal conductivity of the insulation system under the given conditions. It follows that for the determination of heat losses and the related energy saving measures, it is not the declared thermal conductivity that should be used but the values actually occurring in practice. The properties influencing the performance of an insulation system are: ∑ temperature difference ∑ open joints ∑ employed apparent density ∑ convection ∑ moisture ∑ ageing ∑ IR permeability. These should be considered for the intended application, when the insulation system is designed. EN ISO 23993 [1] provides the most important conversion factors for the calculation. Dependent on the insulation material chosen, the insulating effect of the system is influenced through possibly required insulation system related components. The fire behaviour of the insulation material is always to be heeded, since it determines the applicability in the context of the size and intended purpose of the building (residential or public building, number of floors).
11.2
Insulation materials
11.2.1 Fundamentals Insulation materials are on the market in different forms of supply. Depending on the form of supply or on the basic material, they already in themselves constitute the insulation system for given application purposes. In general, however, they constitute a basic material, which is employed together with other materials in the insulation system and the properties of which are changed through the mounting, respectively the mode of application chosen. The expert design of an insulation system requires an appropriate knowledge of the materials used. In the sections below, therefore, next to special forms of supply, available dimensions and a variety of properties in a general form, the fundamental laws of heat transfer in porous substances have been described, to be able to assess the performance profile of an insulation material as placed on the market. This is an important condition
© Woodhead Publishing Limited, 2010
276
Materials for energy efficiency and thermal comfort in buildings
for the design, so that the performance of the final insulation system meets the intended requirements. Basic materials and structures For the insulation of industrial installations in technical building equipment, insulants are available on the market, consisting of basic materials on inorganic or organic bases. They consist of a solid structure of minerals, such as stone, glass, calcium silicate, etc., or of plastic materials such as polyurethane, phenolic resin, polystyrene, polyvinylchloride and vinylrubber with a porous, a closed cellular, an open cellular or a fibrous structure. Forms of supply and dimensions Insulation materials come as dimensionally stable or as flexible products. Dimensionally stable products are boards and pipe sections. Flexible products are mats and felts. Form of supply and flexibility determine their application. They are available with or without facings and support material. Preferred dimensions depend upon form of supply and basic material. Pipe sections are available in lengths from 1000 mm to 1200 mm and in thicknesses up to 200 mm, depending on the inner diameter. Mats and felts are available up to a width of 1200 mm. The lengths depend on the declared thicknesses and lie between 2500 mm and 10000 mm. Declared thicknesses range from 30 mm to 120 mm in 10 mm steps. Boards are available in widths up to 625 mm and lengths up to 1250 mm. They are available in declared thicknesses up to 200 mm, normally also in 10 mm steps. Tubes and insulation sleeves are supplied in a length of 2000 mm and with declared thicknesses from 3 mm to 60 mm. Levels of declared thicknesses must be obtained from the manufacturer. In Table 11.1 the most readily available insulation products for the insulation of industrial installations in technical building equipment have been compiled. Insulation materials may also be produced in situ. Polyurethane in situ foam is an insulation material for flexible employment, preferably for cold protection. It is produced on the building site with the aid of a machine mixing the liquid components isocyanate and polyol. In the so-called pouring method, the liquid mixture is poured through holes into the preassembled cladding. The chemical reaction of isocyanate with the polyol produces heat. The blowing agents in the polyol component evaporate and blow the polyurethane (physical driving). The blowing agent becomes totally or partially the cellular gas. Where water is part of the polyol mixture, the water reacts with part of the isocyanate and generates CO2 which functions as driving gas. However, over time, it will diffuse out of the foam, because
© Woodhead Publishing Limited, 2010
Thermal insulation material for building equipment
277
Table 11.1 Readily available insulation products – material standards, forms of supply and package Insulation material (abbreviated term)/standard/ working document
Form of supply
Mineral wool Pipe sections (MW)/EN 14303 AGI Q 132 Lamella mats Wired mats Boards Felts Loose Fill
Description
Package
Pipe sections Individual of resin bonded packages glass- or rock or wool, with packaged or without in bales grid reinforced aluminium foil facing. Resin bonded glass- or rock wool lamella mat, onesided facing of grid supported aluminium foil
Rolls, bales
Mat made of mineral wool stitched to the wire mesh with galvanized or austenitic steel yarn
Rolls, bales
Boards made of Packages, resin bonded palettes glass- or rock wool Felts made of resin bonded glassor rock wool
Rolls
Loose glass- or rock wool with or without a minimal bonding component
Sacks
© Woodhead Publishing Limited, 2010
278
Materials for energy efficiency and thermal comfort in buildings
Table 11.1 Continued Insulation material (abbreviated term)/standard/ working document
Form of supply
Flexible Tubes elastomeric foam (FEF)/EN 14304/AGI Q 143-1 and Polyethylene foam (PEF) EN 14313/ AGI Q 134-1 Boards or laps Insulation sleeves Extruded Pipe sections polystyrene (XPS) EN 14307/ AGI Q 133-2 Expanded polystyrene (EPS) EN 14309/ AGI Q 133-1 Polyurethane Boards (PUR) and polyisocyanurate foam (PIR) EN 14308/ AGI Q 133-3 Phenolic foam (PF) EN 14314
Description
Package
Tubes of reticulated elastomeric foam or of reticulated or non-reticulated polyethylene foam
Packages
Boards made of resin bonded glassor rock wool
Packages, palettes
Pipe tubes with a non-concentric insulation layer made of nonreticulated or reticulated polyethylene foam
Packages
Pipe sections of Packages extruded/ expanded polystyrene/ polyurethane/ polyisocyanurate/ phenolic foam Boards of Packages extruded/ expanded polytyrene/ polyurethane/ polyisocyanurate/ phenolic foam
© Woodhead Publishing Limited, 2010
Thermal insulation material for building equipment
279
Table 11.1 Continued Insulation material (abbreviated term)/standard/ working document Cellular glass (CG) EN 14305/ AGI Q 137
Form of supply
Boards
Description
Package
Boards of cellular glass
Packages
Table 11.2 Employability as insulant for the different components of industrial installations in technical building equipment, dependent upon the form of supply Form of supply
Vessels flat
Boilers Pipes Ducts
Elbows
Fittings
round
Pipe sections (x) x x Segments Mats x x x x x x Boards x x Felts x x x x Tubes x x x Loose fill x x Granulates x x x x x PUR-in situ foam x x x x x
x
x x x
of its good solubility in polyurethane. But mineral insulants in the form of granulates, too, can be applied with blowing technique, filling cavities behind pre-assembled casings. Applicability and operational temperature range The applicability of the insulation material is determined through its form of supply too (Table 11.2). Its maximum service temperature and/or the fire behaviour, but also its resistance against water vapour diffusion or its mechanical properties, such as compression and tensile strength, determine the limits of its employability. The possible temperature application ranges are shown in Fig. 11.1. It must be observed, however, that for certain applications, use is only possible
© Woodhead Publishing Limited, 2010
280
Materials for energy efficiency and thermal comfort in buildings Flexible elastomeric foam (FEF) Extruded polystyrene foam (XPS) Rigid polyurethane foam (PUR) Polyisocyanurate foam (PIR)
Maximum service
Expanded polystyrene (EPS) Polyethylene foam (PEF) Phenolic foam (PF) Vacuum Insulation Panel (VIP) Cellular glass (CG) Mineral wool (MW) Calcium-magnesium-silicate (CMS) Microporous insulants Minimum service Calcium silicate (CS)
–180 °C
–20 °C
10 °C
100 °C
600 °C
1000 °C
11.1 Temperature application ranges for insulation materials.
in special constructions, and that the manufacturer information regarding the applicability must be heeded. This applies specifically to the use of open cellular insulation materials for a cold insulation. Mineral wool products, for example, may only be employed behind a double skin covering [2] if boundary conditions guarantee that the danger of condensation formation at the object or in the insulation material can be excluded. Important insulation material properties The thermal conductivity l of insulation materials has no constant value. For a suitable design for the area of application of industrial installations, its dependence upon the temperature and the apparent density must be known. In principle the thermal conductivity is a multi-dimensional function of the temperature J, the density r and the thickness s for all insulation materials. Figures 11.2 and 11.3 show these interdependences in a qualitative way. Depending on the apparent density, thermal conductivity increases progressively towards higher temperatures. The thermal conductivity of insulation materials describes a combined heat transfer by thermal conduction via the solid structure and the air plus the radiation exchange. The different portions have different effects depending on the amount of solid structure (apparent density). For example, with materials of apparent densities below roughly 30 kg/m3, the thermal conductivity increases proportionally with increasing temperatures, starting from a relative elevated level at 50 °C. With products of apparent densities above 60 kg/m3 the l;J curves show a slightly lesser dependence upon temperature. Figure 11.3 also shows that the thermal conductivity between raw densities of 40 kg/m3 and 50 kg/m3 shows a relative minimum at a temperature of 50 °C and increases again
© Woodhead Publishing Limited, 2010
Thermal insulation material for building equipment
281
350 in mW/(m.K) Thermal conductivity
300 250 200 150 100 50
1 Ap pa
25 re nt
50
0 0
50
35
50
de
ns
ity
in
45
0
kg
5 /m 3
50 65
15
0 75
0
0 r 25 pe m e T
55
0
4 0 C 35 in ° e r atu
0 50
11.2 Thermal conductivity of insulation materials depending on apparent density and temperature [1].
with increasing apparent densities. At higher temperatures this minimum moves towards higher apparent densities. The understanding of these interdependences is very important for the choice of the optimal product for an intended application. The dependence of thermal conductivity on thickness is of lesser importance compared to the temperature dependence and needs to be reflected in declared values given by the manufacturer according to the provisions of European material standards EN 14303:2009 [3], EN 14304:2009 [4], EN 14305:2009 [5], EN 14306:2009 [6], EN 14307:2009 [7], EN 14308:2009 [8], EN 14309:2009 [9], EN 14313:2009 [10] and EN 14314:2009 [11]. Principally, the so-called thickness effect is a result of the solid structure’s permeability for infrared (IR) radiation. It is very pronounced with insulation materials with apparent densities below 10 kg/m3 and decreases for insulation materials of higher apparent densities. With commercial insulation materials
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort in buildings
W/(m•K tivity in
)
282
0.045
0.025
m
0.08
0.04
hi
0.02
nt
0.08 0.1
rt
0.06 yq uot ie
ye
nsit
La
App 0.04 are nt d e
ne
ss
in
0.06
0.02
m
0.01
ck
c l condu Therma
0.04 0.035 0.03
0
11.3 Thermal conductivity of insulants depending on apparent density and thickness.
of apparent densities above 60 kg/m3 the influence is already negligible for most applications. For the insulation of industrial installations in technical building equipment this effect may be significant with insulation materials made of polyethylene, polystyrene and with the so-called lamella mats made of mineral wool. Lamella mats are used as a multifunctional product for pipes as well as for vessels. Their operational thermal conductivity, therefore, will be dependent upon pipe diameter and insulation layer thickness because of the varying compression. The thermal conductivity is measured according to the following test standards dependent upon the thickness, the form of supply or the temperature range: Test standards for the determination of thermal conductivity lP for boards and mats: ∑ EN 12667:2001: Thermal performance of building materials and products – Determination of thermal resistance by means of guarded hot plate and heat flow meter methods – Products of high and medium thermal resistance. ∑ EN 12939:2000: Thermal performance of building materials and products – Determination of thermal resistance by means of guarded hot plate and heat flow meter methods – Thick products of high and medium thermal resistance.
© Woodhead Publishing Limited, 2010
Thermal insulation material for building equipment
∑
283
prEN15548-1:2006: Thermal insulation products for building equipment and industrial installations – Determination of thermal resistance by means of the guarded hot plate method – Part 1: Measurements at elevated temperatures from 100 °C to 850 °C.
Test standards for the determination of thermal conductivity lR for pipe sections and tubes: ∑ EN ISO 8497:1996: Thermal insulation – Determination of steady-state thermal transmission properties of thermal insulation for circular pipes (ISO 8497:1994) [12]. Fire behaviour The fire behaviour of insulation materials is determined according to EN 13501-1 [13] on the basis of test results obtained using the test standards listed below: ∑
EN ISO 1182:2002: Reaction for fire tests for building products – Non combustibility test. ∑ EN ISO 1716:2002. Reaction to fire tests for building products – Determination of the heat of combustion (ISO 1716:2002). ∑ EN ISO 9239-1:2009: Reaction to fire tests for floorings – Part 1: Determination of the burning behaviour using a radiant heat source (ISO/DIS 9239-1:2008). ∑ EN ISO 11925-2:2002: Reaction to fire tests for building products – Part 2: Ignitability when subjected to direct impingement of flame (ISO 11925-2:2002). ∑ EN 13238:2001: Reaction to fire tests for building products – Conditioning procedures and general rules for selection of substrates. ∑ EN 13823:2002: Reaction to fire tests for building products – Building products excluding floorings exposed to thermal attack by a single burning item. ∑ EN 15715:2007: Thermal insulation products – Instructions for mounting and fixing for reaction to fire testing – Factory made products. As for the determination of thermal conductivity, because of the provisions of EN 15715, the boundary conditions of the test influence the result of the fire behaviour test. According to EN 13501 the following classifications are possible: ∑
Class A1, A1L: Class A1 and A1L products will not contribute in any stage of the fire including the fully developed fire. For that reason they are assumed to be capable of satisfying automatically all requirements of all lower classes.
© Woodhead Publishing Limited, 2010
284
∑
∑ ∑
∑
∑ ∑
Materials for energy efficiency and thermal comfort in buildings
Class A2, A2L: Satisfying the same criteria as class B and BL for the EN 13823. In addition, under conditions of a fully developed fire these products will not significantly contribute to the fire load and fire growth. Class B, BL: As class C and CL but satisfying more stringent requirements. Class C, CL: As class D and DL but satisfying more stringent requirements. Additionally under thermal attack by a single burning item they have a limited lateral spread of flame. Class D, DL: Products satisfying criteria for class E and EL and capable of resisting, for a longer period, a small flame attack without substantial flame spread. In addition, they are also capable of undergoing thermal attack by a single burning item with sufficiently delayed and limited heat release. Class E, EL: Products capable of resisting, for a short period, a small flame attack without substantial flame spread. Class F, FL: Products for which no reaction to fire performances are determined or which cannot be classified in one of the classes A1, A2, B, C, D, E, A1L, A2L, BL, CL, D L, E L.
Additional classifications are possible regarding development of smoke and burning dripping. Additional classifications for the smoke development: ∑ ∑
s3 No limitation of smoke production required. s2 The total smoke production as well as the ratio of increase in smoke production are limited. ∑ s1 More stringent criteria than s2 are satisfied. Additional classifications for the burning dripping/falling ∑ ∑
d2 d1
∑
d0
No limitation. No flaming droplets/particles persisting longer than a given time occurred. No flaming droplets/particles occurred.
Especially in the tests according to EN 13823, the result of which is decisive for the classification into the classes A2, B, C and D, the products can frequently only be tested under end-use conditions, reflecting the applications. Products with fire behaviour classes A2, B, C and D have more or less the same fire behaviour in the condition as placed on the market and under application conditions. This applies to insulation products, e.g. tubes, which in themselves already constitute the insulation system but also where
© Woodhead Publishing Limited, 2010
Thermal insulation material for building equipment
285
the conditions of application are similar to those of the test and no other building components can change the fire behaviour after the application. In particular, fastening means, such as self-adhesive tapes, but also substrates (e.g. material of a pipe which is supposed to be insulated) influence the fire behaviour in the application (see pages 300 and 301, fire behaviour of the insulation system). Since not all possible applications and execution variants can be verified in tests, the limiting conditions of the test are given in EN 15715 for all standardized products for both the product as placed on the market, and the product under end-use conditions. For the declaration of conformity as precondition for the use of the CE mark, only the fire behaviour of the product as placed on the market is relevant. Maximum service temperature The maximum service temperature is determined based on the form of supply according to: ∑ EN 14706:2005: Thermal insulation products for building equipment and industrial installations – Determination of maximum service temperature. ∑ EN 14707:2005+A1:2007: Thermal insulating products for building equipment and industrial installations – Determination of maximum service temperature for preformed pipe insulation. The maximum service temperature is the temperature at which the insulation layer thickness may only decrease by 5% of its original value. For mats this means that, in an application at this temperature, they lose part of their pre-compression. The insulation layer thickness and thereby the thermal resistance remain roughly the same. Eccentricity occurs with the pipe sections at the maximum admissible decrease in thickness, which results in a change of the thermal resistance below 1%. Only for boards does the thickness decrease have a directly proportional effect on the thermal resistance. It also decreases by 5%. It must be remembered, however, that certain applications, especially vibrations or oscillations, constitute an additional strain on the insulation system. Appropriate minimisation factors, dependent upon the application, determine the service temperature [14]. For prefabricated pipe insulation materials such as pipe sections, the maximum service temperature may also constitute the maximum application temperature in installations without vibrations. For a minimum service temperature no test method exists. According to the European product standards, the following properties have to be declared by the manufacturer as a function of the temperature:
© Woodhead Publishing Limited, 2010
286
Materials for energy efficiency and thermal comfort in buildings
∑ contraction coefficient ∑ transverse tensile strength ∑ Young’s modulus, E. This enables assessment of the behaviour of the insulation layer against the movement of the object wall. Another important criterion is brittleness. The consequence of an embrittlement of the insulating material is that the material can crumble, which can lead to a drop of lifetime. The manufacturer should therefore make in any case a statement about the temperature at which an embrittlement of the material begins. Water vapour diffusion For cold protection at industrial installations an insulation system will only maintain its effectiveness when protected against the ingress of moisture. Dependent upon the partial pressure decline between the ambient air and the boundary between insulant and object wall, a water vapour diffusion flow will develop, wherever the water vapour diffusion resistance of the insulation material is limited. Over time this leads to a moistening of the insulation layer. Moisture promotes corrosion and also increases thermal conductivity of the insulation material; the heat ingress increases. Insulation systems at cold insulations must therefore be so designed that no or only very little amounts of moisture can enter. This is either achieved by a so-called vapour barrier, made of vapour-tight layers, e.g. aluminium foil with an sd value > 1500 m, or by using insulation materials whose water vapour diffusion resistance is so high that during the life cycle of the installation no significant moisture ingress occurs. The water vapour diffusion permeability of insulation materials is determined according to the following test standards: For boards and mats ∑ EN 12086:1997: Thermal insulating products for building applications – Determination of water vapour transmission properties For prefabricated pipe insulants (tubes) ∑ EN 13469:2001: Thermal insulating products for building equipment and industrial installations – Determination of water vapour transmission properties of preformed pipe insulation As a property characteristic for low water vapour permeability the water vapour diffusion resistance factor m is used. The water vapour diffusion equivalent air layer thickness (s d value) is given by the following equation.
© Woodhead Publishing Limited, 2010
Thermal insulation material for building equipment
sd = m · s
287
11.1
where sd is water vapour diffusion equivalent-air layer thickness in m, m is water vapour diffusion resistance factor, and s is thickness of the layer in m.
11.2.2 Declared value as a property in the condition as delivered Against the background of the product liability statute (Produkthaftungsgesetz) [15] the manufacturer shall specify the application purpose. On the one hand, it is frequently kept as general as possible to improve success on the market; on the other hand, high risks are involved with too broad a definition of application purposes. Principally the manufacturer declaration is limited to the profile of properties of the product as placed on the market. The profile of properties given indicates the fitness of the insulation material according to the quoted product standard [3] – [11] for the application given. The profile of properties is declared by the manufacturer in the product data sheet. However, the properties of insulants do change in many cases as a result of the installation and the ambient conditions. To convert the properties of the product as placed on the market into the value for the intended application, a satisfactory knowledge of the material and of the pertinent influential factors is required. In particular, knowledge of which influential factors upon their respective property have already been taken into account in the measurement is of high importance. Declared values must be given by the international material manufacturer and be guaranteed for agreed periods. They are always based on measured values and take care of product specific tolerances. Dependent upon the form of supply and/or the components of the insulant, the effects of different influence factors may already be contained in the declared value, since they have been detected in the measurement or are part of the result as purely material specific values. For the declared thermal conductivity these values are: ∑
the temperature difference: high temperature differences during the measurement lead to an integral reference mean value ∑ for joints: additional losses through opening joints caused by different expansion between insulant and object are taken into account in the pipe tester ∑ compression: change of thermal conductivity through change of apparent density through compression during assembly ∑ convection: for air permeable insulants, a small convective part may be contained in the measured value in the pipe tester, e.g. for gaps between test pipe and insulant
© Woodhead Publishing Limited, 2010
288
Materials for energy efficiency and thermal comfort in buildings
∑
gas exchange: thermal conductivity changes through gas exchange as the insulant ages ∑ IR permeability: leads to values dependent upon thickness (thickness effect). For fire behaviour, the substrate and the fastening element can influence the flash behaviour and/or the flue gas development. For maximum service temperatures the test ambient conditions are very important. Thermal conductivity To assess the declared thermal conductivity and its suitability for the application, knowledge of which influential factors are already contained in the declared values is of high importance. Figure 11.4 explains the interrelations. The test method must be chosen dependent upon the form of supply. Pipe sections and pipe tubes may be tested in the pipe tester [3]; boards, however, only in the hot plate test. Multifunctional products, which can equally be used for the insulation of flat objects as of pipes, e.g. wire mats, felts or lamella mats, may be tested in the hot plate [4]–[6] as well as in the pipe tester. How permeable an insulation material is for IR radiation or in how far the cellular gas after the production is in gas exchange with the ambient air, must be established independent of the form of supply. As can be seen in the flow chart in Fig. 11.4, the effects of different influential factors are reflected when determining the thermal conductivity. It is obvious that for plain products such as boards, but also mats and felts, the pure material value is measured if the thermal conductivity is determined in the hot plate apparatus. It can be declared for the intended apparent density dependent upon the temperature. For form pieces (pipe sections or tubes), on the other hand, the measured value already reflects the service thermal conductivity under the given conditions. If the fringe conditions of the test are identical to those in the intended application, no additional conversion factors are needed when determining the design value. It follows that declared thermal conductivities may be used to compare the products of different manufacturers, however, not without knowledge of the influential factors for the comparison of different forms of supply for the intended application. This condition is only met by the service thermal conductivity, e.g. the design value (see Section 11.7.2). The determination of declared values of thermal conductivity is according to the following standards: ∑ EN 13172:2008: Thermal insulating products – Evaluation of conformity. ∑ EN ISO 13787:2003: Thermal insulation products for building equipment
© Woodhead Publishing Limited, 2010
Thermal insulation material for building equipment
289
Insulation product
IRpermeable
no
Thickness effect
no
With cell-gas
Ageing
As pipe section or as tube
no
yes no
Application range
no
yes Guarded hot plate
Pipe section
Compression Losses via gaps
no
l = f(J)
Air permeable
Convection
Test pipe
lB = f(Jm)
11.4 Flow chart to explain the pertinent influential values dependent upon the product and the test method.
© Woodhead Publishing Limited, 2010
290
Materials for energy efficiency and thermal comfort in buildings
and industrial installations – Determination of declared thermal conductivity (ISO 13787:2003). With the aid of a statistical method the production tolerances are taken into account: lP becomes lN,P and lr becomes lN,r, where P is plate, R is pipe section and N is nominal or declared. The thermal conductivity is given in the manufacturers’ literature (product data sheet) as a function of temperature for the intended temperature range, e.g. in the form of a third grade polynomial. this is done in the form of tables, graphs or with the aid of coefficients for the polynomial. In tables the declared thermal conductivity is given with two indicative digits according to the rounding rules of the european standard. For a more exact determination and for the assessment of conformity according to EN 13787 coefficients are being used. For application as insulant in technical building equipment with a limited temperature range between 0 °C and 100 °C, it is sufficient for most insulants to declare the thermal conductivity as a linear equation: lN,P (J) = a0 + a1 · J
in W/((m · K)
11.2
lN,r (Jm) = a0 + a1 · Jm
in W/(m · K)
11.3
where lN,P is declared thermal conductivity for boards and mats in W/(m · K), lN,r is declared thermal conductivity for preformed pipe insulation material in W/(m · K), a0 is: coefficient in W/(m · K), a1 is coefficient in W/(m · K2), J is temperature in °C, and Jm is arithmetic mean between warm and cold side temperature in °C. Since in the display of thermal conductivities with a linear dependence no difference exists between the two equations, it may be harmonised for the given application area in a special form for all products, written like this: lN (Jm) = a0 + a1 · Jm
in W/(m · K)
11.4
where lN is declared thermal conductivity for boards and mats in W/(m² · K), a0 is coefficient in W/(m · K), a1 is coefficient in W/(m · K2) and
Jm =
JW + JK 2
in °C
11.5
where ϑW is temperature of the warm side in °C, JK is temperature of the cold side in °C and Jm is reference mean temperature between warm and cold side temperatures in °C. For tables it is recommended to give the declared values in two indicative digits for the range of reference mean temperatures between 0 °C and 50 °C in steps of 10 °C. table 11.3 gives approximate values for insulation materials for industrial installations in technical building equipment.
© Woodhead Publishing Limited, 2010
Thermal insulation material for building equipment
291
Fire behaviour In section 5 of EN 15715 [16] rules are given for the test conditions of insulation materials for the declaration of fire behaviour in the condition of delivery. This is the precondition for the attestation of conformity and the basis for the declaration of conformity to the standard by the manufacturer. The results of these tests shall be used for the classification according to EN 13501 [13]. Classification is possible in the classes A1, A2, B, C, D and E (see Table 11.4). The class F means ‘not tested’. It can also be the consequence of a test under the provisions for class E not being passed. The fire behaviour in the condition of delivery shall be declared on the label.
Table 11.3 Approximate values for insulation materials for industrial installations in technical building equipment Insulation material Form supply (abbreviated term)
Declared thermal conductivity in W/(m.K) at reference (mean) temperature* in °C
0
10
50
Mineral wool (MW)
Pipe sections Lamella mats Wired mats Boards Felts Loose-wool
– – – – – 0.033–0.036
0.032–0.038 0.036–0.039 – 0.032–0.038 0.034–0.037 0.034–0.037
0.036–0.042 0.043–0.049 0.036–0.044 0.035–0.043 0.039–0.046 0.038–0.042
Flexible elastomeric foam (FEF), Polyethylene foam (PEF)
Tubes/insulation 0.033–0.046 0.034–0.047 sleeves Boards/laps 0.036–0.045 0.037–0.046
0.038–0.050
Extruded polystyrene (XPS), Expanded polystyrene (EPS), Polyurethane (PUR) and polyisocyanurate foam (PIR), Phenolic foam (PF)
Sections Boards
0.025–0.033 0.026–0.034 0.025–0.036 0.026–0.037
0.029–0.038 0.029–0.041
Cellular glass (CG)
Sections Boards
0.042 0.043 0.037–0.039 0.038–0.040
0.051 0.044–0.045
0.038–0.051
*Dependent on the determination method: in the guarded hot plate apparatus ‘reference temperature’, in the pipe tester (pipe sections and tubes) ‘reference mean temperature’. When testing with the guarded hot plate apparatus (boards, mats), the results constitute pure material values: the thermal conductivity is given in relation to temperature. When testing in the pipe tester, the mounting influences are already contained in the measuring result: the thermal conductivity is given in relation to the reference mean temperature.
© Woodhead Publishing Limited, 2010
292
Materials for energy efficiency and thermal comfort in buildings Table 11.4 Possible fire behaviour classes for insulation materials Insulation material made of
Fire behaviour class according to EN 13501
Mineral wool (MW)
A1, A2
Elastomeric foam (FEF), Polyethylene foam (PEF)
B, C, D, E
Polystyrene (XPS) or (EPS), Polyurethane (PUR), Polyisocyanurate foam (PIR),
B, C, D, E
Phenolic foam (PF)
A2, B, C, D, E
Cellular glass (CG)
A1
Table 11.5 Minimum and maximum service temperatures for different insulants Insulation material
Limit service temperatures in °C
Minimum
Maximum
Mineral wool (MW)
< 10*
> 100
Elastomeric foam (FEF), Polyethylene foam (PEF)
< 0
> 90
Polystyrene (XPS) or (EPS)
< 0
< 80
Polyurethane (PUR), Polyisocyanurate foam (PIR), Phenolic foam (PF)
< 0
< 100
Cellular glass (CG)
< 0
> 100
*As an insulant in cold protection additional measures must be taken, e.g. double skin.
Maximum service temperature The maximum service temperature is a property of the insulant as placed on the market. With standardised products it is declared with the denomination code ST(+). For the defined lower service temperature ST(–) the contraction coefficient, the transverse tensile strength and the E-modules have to be declared additionally in the manufacturer’s literature. Insulation materials for the application range of industrial installations in the technical building equipment must have a minimum temperature service range from approximately 0 °C to 90 °C (see Table 11.5).
© Woodhead Publishing Limited, 2010
Thermal insulation material for building equipment
293
Water vapour diffusion The water vapour diffusion resistance factor m is declared at a temperature of 20 °C and shall be declared for standardised products as part of the insulation material designation code (see Table 11.6).
11.2.3 Product data sheet The product data sheet is the manufacturers’ literature with a description of the employment purpose and a profile of properties of the insulation material as placed on the market. The declared values are the basis for the conformity assessment according to the provisions of the standards for both a CE mark and a voluntarily quality certificate, e.g. VDI-Keymark. It is possible to declare properties for special applications. This applies especially for the declaration of a design value of thermal conductivity, or for fire behaviour or application temperatures. Application-related properties may deviate from the material properties as placed on the market.
11.2.4 Declaration of conformity and designation Insulation material manufacturers confirm with a manufacturer’s declaration that their products have been produced in line with the requirements of the respective European material standard and that the declared properties are being met by the average of the production according to the provisions of EN 13172 [17]. For this, the insulation material properties are determined within the framework of an initial type test (ITT) and the products are subject to a singular evaluation of conformity according to EN 13787 by a so-called notified body. The notified bodies are certified test institutions according to Table 11.6 The water vapour diffusion resistance factor m is declared for a temperature of 20 °C Insulation material
Water vapour diffusion resistance factor µ
Mineral wool (MW)* Elastomeric foam (FEF) and polyethylene foam (PEF) Polystyrene (XPS) Polystyrene (EPS) Polyurethane (PUR) and polyisocyanurate foam (PIR) Phenolic foam (PF) Cellular glass (CG)
1 1000–10000 80–250 20–100 30–100 10–50 sd > 1500 m
*As an insulant in cold protection additional measures must be taken, e.g. double skin.
© Woodhead Publishing Limited, 2010
294
Materials for energy efficiency and thermal comfort in buildings
EN ISO 17025 [18] and they have been registered according to the European Directive 89/106/EEC (Construction Products Directive). An obligation for repeated tests in the framework of a third party control, for instance, only exists where the fire behaviour is influenced by additives in the production process (e.g. fire-retarding materials, or limitations of the content of organic substances). The properties of insulants are declared in the manufacturer’s literature (product data sheet). On the package, the different properties of products as placed on the market are given in a designation code and are confirmed by the CE mark. Table 11.7 lists the symbols for the properties, levels and Table 11.7 Symbols for the properties, levels and classes for the designation code Symbol
Declared property, value, level or class
AP AW BS CC(i1/i2/y) sc CL CS(10) CS(10\Y) CS(Y) CV DS(N) DS(T–) DS(T\L) DS(T+) DS(TH)
level of practical sound absorption coefficient level of weighted sound absorption coefficient level for bending strength level for compressive creep level of soluble chloride ions level for compressive stress at 10% deformation level for compressive stress or compressive strength level for compressive strength value for closed cell content class for dimensional stability under normal laboratory conditions value for dimensional stability at –20 °C level for dimensional stability under load and temperature value for dimensional stability at specified temperature value for dimensional stability under specified temperature and relative humidity conditions level of soluble fluoride ions level of water vapour diffusion resistance factor level for water vapour diffusion equivalent air-layer thickness level of soluble sodium ions declared class for flatness tolerance level of the pH value level for penetration under point load class for squareness tolerance level of soluble silicate ions level for minimum service temperature level for maximum service temperature single number descriptor of structure-borne sound class for thickness tolerances level for tensile strength parallel to faces level for tensile strength perpendicular to faces level for water absorption by diffusion level for water absorption by total immersion level for short-term water absorption level for water vapour permanence level for water vapour permeability level for water vapour transmission value for water vapour resistance
F MU MV NA P pH PL(P) S SI ST(–) ST(+) SW T TP TR WD(V) WL(T) WS WVP WVPE WVT Z
© Woodhead Publishing Limited, 2010
Thermal insulation material for building equipment
295
classes for the designation code, and Table 11.8 gives an example of the composition of a designation code for a mineral wool insulant. AGI Working documents of the Q-series for insulants for operational installations in the industry are private sector regulations of constructing divisions in globally operating companies. The working documents do not contradict European standards but show a selection of property profiles of insulation materials which are considered relevant for the application in this area. The product is described and designated using a five-position insulation material designation code. As with European standards, the properties are only declared for the product as placed on the market. These properties are certified through a voluntary conformity attestation procedure, e.g. on the basis of EN 13172, Annex A, and the VDI/Key mark scheme rules through repeated tests by certified test institutes. An evaluation of conformity is rendered by independent certification bodies, authorised according to EN ISO 17011 [19]. The certificate according to the provisions of VDI/Keymark ascertains, on the one hand, the conformity of the product with the information given in the product data sheet and the manufacturer declaration. On the other hand, and simultaneously, it is confirmed that the production process is so controlled that the product is continuously manufactured with unvarying quality. The declaration of properties for special applications is possible on the label and in the product data sheet. A clear division between the properties of the product as placed on the market, and the information for possible applications, e.g. for the insulation for heating installations according EnEV [20] on the label is taken care of (see Fig. 11.5 and Section 11.8.2).
11.2.5 Quality assurance/third party control Properties like thermal conductivity or fire behaviour cannot be checked by the user. Quality assurance systems such as the certification according to the provisions of the VDI/Keymark are confidence building measures and confirm for the user that the products are in line with the information given in the product data sheet. The VDI/Keymark confirms by a continuous quality control manufacturers’ declarations regarding the properties of their products. Unlike the manufacturer’s Table 11.8 Example for the composition of a designation code for a mineral wool insulant Product Number of Thickness abbreviation standard tolerances
Maximum Water Water service absorption soluble temperature chloride ions
MF
ST(+) … …
EN 14303
T2
WS
© Woodhead Publishing Limited, 2010
CL
296
Materials for energy efficiency and thermal comfort in buildings
Manufacturer logo
Pipe Section Mineralwool pipe section EN 14303 Reaction to fire – Class A1 T2–ST(+)250–WS1–MV1–CL6–pH9,5
0123 Manufacturer 08 Thermal conductivity see Manufacturer’s Literature Address 01234-CPD-00234 AGI Q 132 insulation designation code: 10.04.02.25.99 08120501
Manufacturer Z-23.14-XXXX
EAN code
Inner diameter mm
Insulation thickness mm
Length mm
Number of pieces per pack
22
23
1000
20
Application: Insulation of pipes within buildings according to German EnEV Design value of thermal conductivity: 0.037 W/(m • K) at 40 °C mean temperature Reaction to fire – Class A2 other Applications….
11.5 Example of a label for the designation of an insulation material for the insulation of operational installation in the technical building equipment.
declaration, which must be given by the manufacturer to obtain the right to use the CE mark, and which is solely based on an initial type test, the VDI/ Keymark notifies continual product reliability. In cases, e.g. for defined markets, the provisions of locally responsible building authorities’ certificates, against the background of national building law (e.g. in Germany with a general building authority certification), demand third party tests. The resulting and required declaration of conformity confirms for users and builders the acceptability of this building product under national building law. The properties tested according to these criteria may deviate from the properties of the product as placed on the market (see Sections 11.7 and 11.8).
11.3
Form pieces and form parts
Fittings and elbows in operational installations in technical building equipment are being insulated with insulation material form pieces, which are clad by form parts, e.g. boxes, or with loose wool, which is stuffed into prefabricated form parts. Examples are given in Figs 11.6 and 11.7. The thermal insulating effect of fittings and other installation related thermal bridges is expressed with the product of the thermal transfer coefficient U or k and the heat releasing surface A (U ¥ A or k ¥ A). The heat loss via
© Woodhead Publishing Limited, 2010
Thermal insulation material for building equipment
297
11.6 Example of a form piece made of polyurethane with a cladding for the insulation of fittings and valves [1].
11.7 Example of a pre-manufactured form piece for the insulation of fittings and valves with loose wool [1].
an insulated fitting is calculated with the following equation if k and A are known:
Q˙ WB = k · A · (JM – JL)
in W
11.6
where Q˙ WB is heat loss in W, k is thermal transfer coefficient of the box insulation in W/(m² · K), A is surface of the box in m², JM is medium temperature in °C, and JL is ambient temperature in °C.
11.4
Support and spacer ring constructions
Support constructions are components of insulation systems to transfer loads, resulting from the cladding. Spacer ring constructions are supported by the object wall or the insulant and keep the cladding of the insulation system at the correct distance.
© Woodhead Publishing Limited, 2010
298
Materials for energy efficiency and thermal comfort in buildings
Support and spacer ring constructions are insulation-related thermal bridges. They are taken into consideration when calculating the service thermal conductivity with an additive term Δl. Approximate values for this additive term are given in EN ISO 23993 [1] or in VDI 2055 Part 1 [21], dependent upon the type of spacer ring construction.
11.5
Vapour retarder materials
In order to prevent or reduce moisture penetration of the insulating layer with objects with temperatures under ambient temperature it is to examine, according to EN 14114 [22] or VDI 2055 part 1 [21] it is necessary to determine whether a suitable vapour barrier on the side of the higher temperature is necessary (see Table 11.9).
11.6
Claddings
The cladding is a mechanical protection of the insulation material. The cladding material may change the fire behaviour of the insulation system. The emissivity of the cladding influences the resulting surface temperature and the density of heat flow rate (see Table 11.10).
11.7
Insulation system
11.7.1 General Occasionally, the conformity to the standard of insulants is a fundamental prerequisite for the construction of a professionally satisfactory insulation Table 11.9 Vapour retarder materials Vapour retarder materials
sd = m . s
Polyethylene film (s = 0.1 mm to s = 1.2 mm) Polyvinyl chloride film (s = 0.3 mm to s = 0.8 mm) Aluminium foil (s ≥ 0.050 mm)
10–100 30–40 > 1500
Table 11.10 Emissivity e of various surfaces Material and conditions of surface
Emissivity e
Aluminium foil, bright Aluminium, bright-rolled Aluminium-zinc, smooth polished Steel, galvanised, bright Paint-coated sheet metal Plastic casing Elastomer foamed material
0.05 0.05 0.16 0.26 0.9 0.9 0.9
© Woodhead Publishing Limited, 2010
Thermal insulation material for building equipment
299
system. Dependent on the form of supply, the thickness of the insulation product as delivered will also be the insulation layer thickness of the insulation system. This is especially true for boards, pipe sections and tubes. With multifunctional and flexible insulation materials the installed insulation layer thickness may be influenced by the application. The insulation layer thickness determines, together with the thermal conductivity, the insulating efficiency. At least for plane walls it is directly proportional to the thermal resistance of the insulation system. For pipe insulations, the logarithm of the quotient of external and internal diameters determines the thermal resistance. Tolerances for length, width and rectangularity of insulation products influence indirectly the quality of the system and its efficiency. Differing measures or deviations from rectangularity of individual boards or pipe sections constitute unnecessary sources for mistakes in the application or require additional attention and thus an increased effort in the insulation work.
11.7.2 Properties Operational thermal conductivity of the insulation system When applying the insulation material in an insulation system, the thermal insulating properties may change. Dependent upon the insulation material chosen, probably required insulation system related components, such as support and spacer ring constructions, influence the thermal insulating effect of the system. The effective thermal and cold protection is determined by the operational thermal conductivity of the insulation system. Insulation contractors guarantee that it is smaller or in extreme cases equal to the design value of thermal conductivity. A precondition is that while applying the materials chosen, such as insulant, support and spacer ring construction, additives and cladding, the following is made sure in every case: ∑ ∑
no open joints, circumferential or longitudinal, stepped joints in multilayer insulations, no cavities no gaps between object wall and insulant through appropriate contact pressure, and for cold insulations the installation of undamaged vapour retarders to prevent the ingress of moisture or at least to lessen it.
A professional insulation contractor is also obliged to check the fitness of materials used for the intended application within the framework of his goods input control, and raise objections where appropriate. Since it is not practically feasible to check all properties on the building site, such as declared thermal conductivity, longitudinal air flow resistance, hydrophobic qualities, AS quality, water vapour diffusion resistance, maximum service temperature, emissivity of cladding sheet metal, and thermal bridges effect of
© Woodhead Publishing Limited, 2010
300
Materials for energy efficiency and thermal comfort in buildings
support and spacer ring constructions, it is recommended always to require the manufacturer to present an attestation of conformity by an accredited certification body. Only the thickness and the conformity of apparent density can be checked on the building site. In particular, the apparent density of insulation materials is considered the most important indirect quality mark (see Figs 11.2 and 11.3). The radiation permeability and thereby the dependence of temperature and thickness are being determined by it. With wired mats, lamella mats and felts, the apparent density changes in the application and thus properties, especially thermal conductivity, do change. Unlike with most applications when insulating building envelopes, apparent density plays an important role in the insulation of industrial installation also as direct quality requirement. With high insulation layer thicknesses, the insulation material constitutes loads that cannot be disregarded. This is the reason why the apparent density will always be declared by manufacturers, even if not mandatory according to European standards. Where deviations from the intended and ordered product properties are detected in the goods input control, it must be checked whether the conversion factors according to EN ISO 23993 [1] or VDI 2055 part 1 [21] for the calculation of design and values are still valid. It is calculated from the nominal values of the thermal conductivity:
l = Pf · lN + Dl in W/(m · K)
11.7
where Pf is product of all effective factors according to EN ISO 23993 or VDI 2055 Part 1, lN is declared thermal conductivity, and Dl is reference values for losses from thermal bridges or inserts. For the given application in technical plants and in technical building equipment, this amounts to Pf ª 1 and Dl = 0, so that for the given temperature range
l ª lN in W/(m · K)
11.8
can be set. Fire behaviour of the insulation system Products, especially with fire behaviour classes A2L, BL, CL and DL, may display more or less the same fire behaviour under the conditions of delivery and in the application, comparable to products, the thermal conductivity of which has been tested in the pipe tester according to EN ISO 8497 [12]. This applies for insulation products, e.g. tubes, constituting in themselves the insulation system, or where similar conditions prevail in the application as in the test and where no additional components can change the fire behaviour after the application.
© Woodhead Publishing Limited, 2010
Thermal insulation material for building equipment
301
especially with tests according to eN 13823 where results are decisive for the classifications into classes A2, B, C and D, respectively A2l, Bl, Cl and Dl, it is frequently only possible to test products under extreme conditions approaching end-use conditions. Fastening means such as adhesive tapes, but substrate materials too (e.g. the material of the pipe to be insulated), influence fire behaviour in the application. Since it is impossible to check with tests every application case and all possible execution variations, the test fringe conditions are given for all standardised products in eN 15715 [16] determining product parameters (as placed on the market) and application parameters (in end-use condition). For the declaration of conformity, as a precondition for the right to use the Ce mark, only properties of products as placed on the market are relevant. However, occasionally they also may cover certain application cases.
11.8
Heat loss of the operational installation in technical building equipment
the heat loss of an operational installation in the technical building equipment, respectively the heat ingress, is not determined solely by the service thermal conductivity of the insulation system, but naturally also by the insulation layer thickness installed, and by the surface heat transfer conditions. the choice of suitable cladding sheet metal, observing the emissivity, can likewise reduce the density of heat flow rate. Plant-related thermal bridges, too, such as supports, fittings and valves exert decisive influence on the total heat loss Q˙ of an operational installation in the technical building equipment. the overall heat loss Q˙ is decisive for the primary energy effort required. Under neglect of the internal heat transfer coefficient the total heat loss is valid for: Pipes Q i =
JM – Jl · l in W d 1 1 · ln a + 2·p ·l di a a · da · p
11.9
Boiler and vessels
J – Jl Q i = M · A in W s+ 1 l aa
11.10
where JM is medium temperature in °C, Jl is ambient temperature (air) in °C, l is designed value in W/(m · K), da is diameter of the insulation exterior in m, di is diameter (insulation internal) in m, s is layer thickness in m, l is
© Woodhead Publishing Limited, 2010
302
Materials for energy efficiency and thermal comfort in buildings
length of the pipe in m, A is surface of boiler or vessel in m², and aa is heat transfer coefficient (cf Table 11.11). Also the plant-related thermal bridges such as supports, armatures and valves exert crucial influence on the total heat loss Q˙ gen,is [24] of a technical plant for building equipment and industrial installations. The total heat loss Q˙ is contributing for the necessary primary energy expenditure.
n
m
i =1
j =1
Q gen,is = ∑ Q i + ∑ Q WB, j
in W
11.11
where Q˙ gen,is is total heat loss in W, Q˙ i is heat loss over the thermal insulation of the components in W, and Q˙ WB,j is heat loss from plant related thermal bridges (supports, fittings and valves) in W.
11.8.1 Required insulation layer thicknesses Insulation layer thicknesses required should, therefore, today be designed under the aspects of energy saving in connection with the challenge of climate protection and not only according to the criteria of contact protection or the prevention of condensate at the surface of the insulation. Heat losses via installation-related thermal bridges must be taken into account, to allow for an energy consumption related evaluation of an industrial installation. Where the heat loss cannot be directly reduced through insulation measures, it is recommended to increase the insulation layer thickness for pipes and vessels compared to insulation layer thicknesses calculated under purely operational aspects. The design can be assisted by economic considerations. Dependent upon the cost for the primary energy needed to operate the installation, a so-called economic insulation layer thickness results, which leads to marginal cost increases when further increased, but shows nevertheless very short payback periods. Insulation measures over and above the dimension required to fulfil operational demands lead to a reduction of overall heat losses. The difference Table 11.11 Reference values for the heat transfer coefficient of claddings for insulation of building equipment estimated according EN 12421 [23] and VDI 2055 Part 1 [21] Material and conditions of surface Emissivity e
heat transfer coefficient ao in W/(m² · K)
Aluminium foil, bright Aluminium, bright-rolled Aluminium-zinc, smooth polished Steel, galvanised, bright Paint-coated sheet metal Plastic casing
4 4 5 6 9 9
0.05 0.05 0.16 0.26 0.9 0.9
© Woodhead Publishing Limited, 2010
Thermal insulation material for building equipment
303
ΔQ˙ of heat losses according to these two criteria [21] and Technical Letter No. 6 [25], constitutes an important contribution to energy savings.
11.8.2 National regulations With EnEV (Energy Savings Directive) [20] Germany shows a pragmatic approach. Dependent upon whether or not heat losses contribute to the thermal economy of a building, pipes up to DN 100 must be insulated with a layer thickness representing 50% or 100% of the pipe diameter. Upwards of DN 100 the required insulation layer thicknesses are 50 mm or 100 mm. The insulation layer thicknesses apply to a design value (service thermal conductivity) ≤ 0.035 W/(m · K). For insulation materials with other design values the insulation layer thicknesses must be calculated in relation [26]. From an operational point of view, respectively according to the criteria of contact protection, these insulation layer thicknesses are totally oversized; however, according to the criteria of energy saving, they make sense and they are recommended for the energy efficiency of the installation. The design value for insulation materials is regulated together with the classification of fire behaviour in a general Building Authority Acceptance (ABZ) of the DIBt, Berlin. Where insulation materials are being produced according to European standards [3]–[11], they must be designated according to the provisions of those standards. Special properties, e.g. a design value or a fire behaviour class for special applications, shall be declared clearly distinct from the CE marking (see Fig. 11.5 and Section 11.2.4). With the Ü-mark, confirmation is given to the user of the insulation material, that ‘conformity’ prevails between the product and the provisions of the General Building Authority Acceptance for the described purpose of application ‘insulation of heating installations’ and is especially authorised. A proper execution of this directive by insulation contractors, using accepted insulation materials and layer thicknesses demanded by regulations, constitute a small contribution to climate protection.
11.9
References
1. EN ISO 23993:2008: Thermal insulation products for building equipment and industrial installations – Determination of design thermal conductivity. 2. DIN 4140: Dämmarbeiten an betriebstechnischen Anlagen in der Industrie und in der technischen Gebäudeausrüstung – Ausführung von Wärme- und Kältedämmungen; Ausgabe: 2008-03 [Insulation work on industrial installations and building equipment – Execution of thermal and cold insulations; Version: 2008–03]. 3. EN 14303:2009: Thermal insulation products for building equipment and industrial installations – Factory made mineral wool (MW) products – Specification. 4. EN 14304:2009: Thermal insulation products for building equipment and industrial installations – Factory made flexible elastomeric foam (FEF) products – Specification. © Woodhead Publishing Limited, 2010
304
Materials for energy efficiency and thermal comfort in buildings
5. EN 14305:2009: Thermal insulation products for building equipment and industrial installations – Factory made cellular glass (CG) products – Specification. 6. EN 14306:2009: Thermal insulation products for building equipment and industrial installations – Factory made calcium silicate (CS) products – Specification. 7. EN 14307:2009: Thermal insulation products for building equipment and industrial installations – Factory made extruded polystyrene foam (XPS) products – Specification. 8. EN 14308:2009: Thermal insulation products for building equipment and industrial installations – Factory made rigid polyurethane foam (PUR) and polyisocyanurate foam (PIR) products – Specification. 9. EN 14309:2009: Thermal insulation products for building equipment and industrial installations – Factory made products of expanded polystyrene (EPS) – Specification. 10. EN 14313:2009: Thermal insulation products for building equipment and industrial installations – Factory made polyethylene foam (PEF) products – Specification. 11. EN 14314:2009: Thermal insulation products for building equipment and industrial installations – Factory made phenolic foam (PF) products – Specification. 12. EN ISO 8497:1996: Thermal insulation – Determination of steady-state thermal transmission properties of thermal insulation for circular pipes (ISO 8497:1994). 13. EN 13501-1:2007: Fire classification of construction products and building elements – Part 1: Classification using data from reaction to fire tests. 14. AGI Q 101: Insulation work on power plant components – Execution; Version: 2000-07. 15. ProdHaftG Gesetz, 1989-12-15. Gesetz über die Haftung für fehlerhafte Produkte (Produkthaftungsgesetz) geändert durch ProdHaftRVÄndG, Gesetz 2000-11-02. 16. prEN 15715:2007: Thermal insulation products – Instructions for mounting and fixing for reaction to fire testing – Factory made products. 17. EN 13172:2008: Thermal insulating products – Evaluation of conformity. 18. EN ISO/IEC 17025:2005-08: General requirements for the competence of testing and calibration laboratories (ISO/IEC 17025:2005). 19. EN ISO/IEC 17011:2004: Conformity assessment – General requirements for accreditation bodies accrediting conformity assessment bodies (ISO/IEC 17011:2004). 20. EnEV: 2007-07-24: Verordnung über energiesparenden Wärmeschutz und energiesparende Anlagentechnik bei Gebäuden (Energieeinsparverordnung – EnEV). 21. VDI 2055 Part 1: Thermal insulation of heated and refrigerated operational installations in the industry and the building services – Calculation rules: Technical rule, 2008–09. 22. EN 14114:2002: Hygrothermal performance of building equipment and industrial installations – Calculation of water vapour diffusion – Cold pipe insulation systems. 23. EN 12421:1998: Magnesium and magnesium alloys – Unalloyed magnesium. 24. EN 15603:2008: Energy performance of buildings – Overall energy use and definition of energy ratings. 25. Technischer Brief Nr. 6: 2008-10: Hohe Rentabilität bei umweltgerechten Isolierschichtdicken – High profitability through ecologically based insulation thicknesses. 26. DIN V 4108-4:2007-06: Thermal insulation and energy economy in buildings – Part 4: Hygrothermal design values. © Woodhead Publishing Limited, 2010
12
Reflective materials and radiant barriers for insulation in buildings
D. W. Y a r b r o u g h, R&D Services Inc., USA
Abstract: Reflective insulations and radiant barriers are products used to reduce radiative transport across air spaces. The physical basis for these products, methods of testing, and the standards for reflective-type products are discussed in this chapter. Selected references to the existing literature are included. Key words: reflective insulation, radiant barriers, heat flux, convection, radiation, reflective air space, emittance.
12.1
Background and definitions
Thermal insulations used in buildings use the low thermal conductivity of gases to reduce heat flow. Mineral fiber, cellulosic, and open-cell plastic insulations use air as the low thermal conductivity component. The purpose of the fibrous or cellular material is to prevent free convection and reduce radiation. Cellular plastic insulation containing low thermal conductivity gases can provide thermal resistance greater than the air products as long as the gas remains in the cells. High thermal performance insulations based on evacuated powders or fibers or insulations with small diameter fibers or particles provide very high thermal resistance by reducing gas-phase conduction. Reflective insulations and radiant barriers are a class of materials that also rely on the low thermal conductivity of air for their performance. The thermal resistance of a reflective system is always less than the thermal resistance of an air space without convection or radiation since reduced pressure or nano-scale particles are not involved. Reflective insulations and radiant barriers are materials used to reduce the transport of energy across air spaces in a building envelope. Both types of materials include surfaces with low emittance and high reflectance in the thermal spectrum (2–50 mm), i.e. near infra red (NIR) to mid infra red (MIR). These surfaces significantly reduce radiation across adjacent air spaces. Reflective insulation systems are characterized by having enclosed air spaces adjacent to low-emittance surface(s) while radiant barrier systems are associated with large ventilated or unventilated air spaces. Reflective insulation systems generally include air spaces up to about 0.25 m in the 305 © Woodhead Publishing Limited, 2010
306
Materials for energy efficiency and thermal comfort in buildings
direction of heat flow. Radiant barriers systems generally have air spaces larger than 0.5 m. Reflective insulation materials consist of one or more aluminum foils or metallized aluminum films bound to substrates (core material) primarily for mechanical support. The supporting materials include paper-type materials, plastics, or wood. In some cases the supporting material has a thermal resistance because of its thickness. Plastic bubble products or fiberglass batt material, for example, are used as core material. The thickness of the core material is generally in the range 3–25 mm. The thermal resistance of the core material is usually a small part of the overall resistance of the reflective air space. The thermal resistance is the result of reduced radiative transport across the enclosed air space and limited free convection. Reflective insulation systems have thermal resistances or R-values that can be measured and calculated. The thermal resistance of a reflective air space depends on orientation since there is a convective component of heat flow across the air space. Reflective insulations are commonly labeled with R-values for heat flow up, horizontal, and down. Radiant barrier materials are most commonly single sheet materials consisting of aluminum foil or film bonded to reinforced plastic or paper or in some cases wood sheathing. A well-established North American product consists of foil bonded to oriented strand board for use as roof sheathing. Radiant barrier systems that consist of both a low-emittance surface facing a large air space with one or more enclosed reflective air spaces are also in use. These systems provide reduced radiative transport across the air space (radiant barrier) and thermal resistance associated with the reflective air spaces. Radiant barrier systems are evaluated in terms of reduced heat flow across the bounding air space rather than R-value. The performance of a radiant barrier system depends on the heat flow direction. This means that winter and summer performance for attic or roof mounted radiant barriers will be different. The performance of attic radiant barriers can be estimated for a given geographical location using computer modeling such as that described in ASTM C 1340. The modeling provides annual load reductions based on local weather data. Both reflective insulation systems and radiant barrier systems can be achieved with liquid coatings having emittances in the range 0.20 to 0.30. At the present time, however, liquid coatings with emittances as low as aluminum foil or film are not available. The energy savings potential of liquid radiant barrier systems, therefore, is lower that that of the foil or metallized film products. Aluminum has been the material of choice for reflective products because of its low emittance and relatively low cost. The emittance of aluminum foil products is in the range 0.03 to 0.05 on a scale of 0 to 1. Aluminum film products have slightly higher emittances because the deposited metallic
© Woodhead Publishing Limited, 2010
Reflective materials and radiant barriers for insulation
307
surface must be protected from the surrounding atmosphere. The results of thin coatings to protect the metallized surface are emittances in the range 0.04 to 0.08. Long-term performance of a reflective system requires maintenance of low emittance. Contamination by dust or other debris or water damage increases the emittance and reduces savings. Cook et al. [1] have measured the effect of dust on emittance by distributing measured amounts of fine dust on a foil surface and measuring the resulting emittance using ASTM C 1371. The emittance increases from 0.03 to about 0.85 as the weight per unit area of dust was increased from 0 to 8 mg/cm2. Many of the common building materials have emittances in the range 0.8 to 0.9. The heat flux, Q/A (W/m2), from a warm surface to a cool surface is described by a heat transfer coefficient for conduction and convection, hc (W/m2·K), and a radiation term, Ehr, as shown by Eq. 12.1,
Q/A = (hc + Ehr) ∙ DT
12.1
where DT is the difference in temperature between the surfaces. The term hc includes conduction and convection while hr accounts for the radiative transfer. Equations and data for hc and hr will be discussed in following sections. The E in Eq. 12.1 is the effective emittance for the air space. E depends on the emittances of the surfaces bounding the enclosed air space. Reflective insulations and radiant barriers are produced with surfaces that result in E near zero. Equation 12.1 can be used to describe the heat flux to or from a surface to adjacent air if E is taken to be the emittance of the surface. Reflective insulation systems have R-values that depend on orientation, bounding temperatures, and the physical design of the system. Radiant barrier system performance is commonly stated in terms of heat flow or heat flux reduction. Heat flow is the product of heat flux and area. The commonly used units for these quantities are given in Table 12.1.
12.2
Applications and assemblies
The thermal performance of a reflective insulation system depends on heat flow direction, temperature difference across the air space, the average temperature, and the thermal emittances of the surfaces bounding the air space. Table 12.1 Units for reflective systems Description
Scientific Inch-Pound international
Conversion from SI to IP
Thermal Resistance (RSI) Heat flux Heat flow
m2∙K/W
ft2·h·°F/Btu
Multiply by 5.678
W/m2 W
Btu/ft2∙h Btu/h
Multiply by 0.319 Multiply by 0.293
© Woodhead Publishing Limited, 2010
308
Materials for energy efficiency and thermal comfort in buildings
The dependence of RSI on the distance across the air space is illustrated in Fig. 12.1 for three directions of heat flow. The thermal resistance for heat flow upward or horizontal maximizes at about 25 mm while the thermal resistance for downward heat flow increases with the distance across the air space. The downward heat flow is affected by stratification of the air with low-density air being at the top of the space. R-values for commercial products are usually less than R-values calculated for large parallel planes partly because of radiation absorbed by framing or supports (multi-dimensional effects). A reflective insulation installed in a space of fixed dimensions can consist of one air space or multiple air spaces. Subdivision of a given space into two or more smaller air spaces will increase the overall thermal resistance by reducing both the radiative and the convective components of heat transfer. The convective component has a strong dependence on the temperature difference across the air space. Dividing a space into two regions, for example, will reduce the temperature drop across each space by a factor of about two with a corresponding reduction in convection. Table 12.2 contains calculated values for the thermal resistance of reflective air spaces at mean temperature Table 12.2 Calculated thermal resistances for selected reflective air spacesa Thermal Resistance (m2·K/W) Air space
Temperature difference
Heat flow direction
(mm)
(°C)
(Up)
(Horizontal)
(Down)
12 24 36 12
10 10 10 15
0.33 0.36 0.38 0.30
0.41 0.60 0.57 0.40
0.42 0.76 1.03 0.42
Tmean = 25 °C, emittances 0.9 and 0.03 1.4 1.2 Thermal resistance
a
1.0 Down
0.8
Horizontal
0.6
Up
0.4 0.2 0.0
0
10
20
30 40 Air space (mm)
50
60
12.1 Thermal resistance (RSI in m2·K/W) at T = 25 °C and DT = 10 °C.
© Woodhead Publishing Limited, 2010
Reflective materials and radiant barriers for insulation
309
25 °C bounded by large parallel planes that illustrate the effect of air space dimensions and temperature difference on the thermal resistance. The installation of a single layer reflective insulation material in the middle of a wall cavity or between floor joists to produce two enclosed air spaces is a very common application. Table 12.3 contains calculated thermal resistances for a fixed space divided into small regions. The results are based on large, parallel thin reflective membranes installed in a 50 mm wide space. The heat flow direction is horizontal and membrane thickness is neglected for the thermal resistances in Table 12.3. The cost associated with producing two low emittance surfaces for each air space often rules out this type of design since the added thermal performance shown in Table 12.3 is modest. Commercial products have existed with up to nine enclosed air spaces in series when a high R-value system is required. Figure 12.2 shows examples of assemblies that have been used for woodframe or metal-frame structures. The core material for the reflective material can be either a single-sheet material, foam, or plastic bubble structure.
12.3
Basis for thermal performance
The performance of reflective insulations and radiant barriers is based on a reduction in heat transfer by radiation between hot and cold surfaces. The radiative flux Q/A (W/m2) from a surface at an absolute temperature, T, with emittance e, is readily calculated from the Stefan–Boltzmann equation where s, the Stefan–Boltzmann constant, equals 5.67 ¥ 10–8 W/m2·K4. The radiative flux is directly proportional to the emittance, a property that varies from 0 to 1. Reflective insulations and radiant barriers utilize materials with low emittance surfaces. Aluminum foils with emittances in the range 0.03 to 0.04 have been a popular choice. Metallized aluminum films with protective coatings have come into use in recent years.
Q/A = e∙s∙T 4
12.2
Table 12.3 Effect of dividing a fixed space to produce multiple air spacesa Number of air spaces
R-values (m2·W/K)
One side of each air space with low emittanceb
Both sides of each air space with low emittancec
1 2 3
0.44 1.20 1.63
0.46 1.27 1.68
a
Total space 50 mm, bonding temperatures 15 °C and 25 °C Low emittance side 0.03 with high emittance side 0.9 c Both sides of air space with emittance 0.03 b
© Woodhead Publishing Limited, 2010
310
Materials for energy efficiency and thermal comfort in buildings
Single foil products
Two foils (one or two air gaps)
Three foils (three or four air gaps)
Multifoil configurations
Support structure
Reflective surface
Non-reflective surface
12.2 Examples of reflective insulation assemblies.
The net radiative transfer between parallel surfaces depends on the temperatures of the surfaces, the emittances of the surfaces, and the orientation of the surfaces. If surface 1 is hot and surface 2 is cold, then the net radiative transfer (Q12) is given by Eq. 12.3 where the term F12 is the overall interchange factor.
Q12 = s ∙A1∙ F12·(T14 – T24)
12.3
The evaluation of F12 is discussed in detail in the heat transfer literature. In the case of reflective insulation systems the discussions are generally limited to radiative transfer between large parallel surfaces with emittances e1 and e2. In this case, the interchange factor is expressed by Eq. 12.4. The interchange factor in this case is commonly called the ‘effective emittance (E)’.
F12 = E = 1/(1/e1 + 1/e2 – 1)
© Woodhead Publishing Limited, 2010
12.4
Reflective materials and radiant barriers for insulation
311
In building application, the temperature differences (T1 – T2) are relatively small with the result that the radiative heat flux can be approximated as follows. Q12/A1 = 4·E·s·Tm3 ·DT = E·hr Tm = (T1 + T2)/2 DT = T1 – T2
12.5
The heat flux due to convection-convection is represented by hc with the resulting total heat flux being the sum of the two terms. The units for hc and hr are W/m2·K. Qtotal/A = (E·hr + hc)·DT
12.6
A combination of Eq. 12.6 with the definition of R-value gives an expression for the thermal resistance of the enclosed air space. R-value =
DT = 1 Qtotal (E ·hr + hc ) total /A
12.7
The term hc depends on the heat flow direction since it includes buoyancy driven free convection. The standard ISO 6946 contains equations for estimating hc for two important cases. Case 1 is an unvented space with length and width both more than 10 times the thickness, d. Figures 12.3, 12.4, and 12.5 show hc based on ISO 6946 as a function of the air gap, d, for the three major heat flow directions for the case DT across the air gap less than 5 K. Case 2 involves regions that don’t conform to the Case 1 dimensional requirements. There are many cases where a small temperature difference across the air gap is valid. If d is small, convection is absent and hc gives conductive transport at 10 °C. There are two curves in each of the three figures. The curves shown with diamonds represent a conduction dominated region. The Downward
14 12 hc (10 °C)
10 8 6 4 2 0
0
5
10
15
20
25
30
35 40 45 50 Air gap (mm)
55
60
65
70
75
80
12.3 Downward heat flow values for hc (10 °C) based on ISO 6946 for DT £ 5 K.
© Woodhead Publishing Limited, 2010
312
Materials for energy efficiency and thermal comfort in buildings Upward
14 12 hc (10 °C)
10 8 6 4 2 0
0
5
10
15
20
25 30 Air gap (mm)
35
40
45
50
55
12.4 Upward heat flow values for hc (10 °C) based on ISO 6946 for DT £ 5 K. Horizontal
30 25 hc (10 °C)
20 15 10 5 0
0
5
10
15
20 25 30 35 Gap thickness (mm)
40
45
50
55
12.5 Horizontal heat flow values for hc (10 °C) based on ISO 6946 for DT £ 5 K.
curves shown as squares are for convection. R-values are calculated using the greater of the two values at a given gap thickness. The figures illustrate the onset of convection in a reflective air space. The curves for downward heat flow intersect at 60.7 mm. The curves for upward heat flow intersect at 12.8 mm while the curves for horizontal heat flow intersect at 20 mm. Convection is absent for air gap thicknesses less than the preceding values. Table 12.4 contains hc values for d greater than the intersection points. ISO 6946 provides a method for calculating the radiative term when the air space does not satisfy the dimensional requirement stated earlier or the temperature difference across the air gap exceeds 5 K. Both of these conditions will reduce the thermal resistance of the air gap. An increase in the temperature difference results in increased convective transport while narrowing the width of the air space increases the radiative transport. Annex B in ISO 6946 contains the equations for making R-value calculations. An extensive set of hot box measurements for reflective air spaces were made at the US National Bureau of Standards by Robinson and Powell in 1954 [2]. A second major set of hot box measurements were published by
© Woodhead Publishing Limited, 2010
Reflective materials and radiant barriers for insulation
313
Table 12.4 Values for hc for air gaps that exhibit convection
hc (W/m2·K)
Air gap (mm)
Down
Horizontal
12.8 20.0 1.25 60.7 0.41 1.25 65.0 0.40 1.25 70.0 0.39 1.25 75.0 0.38 1.25
Up 1.95 1.95 1.95 1.95 1.95 1.95
Desjarlais and Yarbrough in 1991 [3]. These data have been used to establish correlations for hc that include dependence of air gap temperature, air gap temperature difference, effective emittance, and heat flow direction. The graphical results in Fig. 12.1 were calculated using the correlations from the hot box tests. Equations for calculating hc that are based on the NBS hot box data are in the 1991 paper mentioned above.
12.4
Measurement of thermal performance
The thermal performance of reflective air spaces is generally determined using a hot box facility. Relatively large test specimens (2.5 ¥ 3 m, for example) can be evaluated using a hot box facility. A flat test specimen is bounded on one side by a region containing a heater. The second side of the specimen is bounded by a temperature-controlled space. At steady state, the energy input to maintain a constant temperature on the hot side establishes the heat flux through the test specimen. The temperature difference between the hot and cold regions is the DT. Equation 12.7 can then be used to calculate the R-value which is the thermal resistance from the air space on the hot side of the specimen to the air space on the cold side of the specimen. Addition instrumentation provides the thermal resistance between the exterior or interior surfaces of the test specimen. Parallel-path heat flow calculations are used to isolate the thermal resistance of an enclosed cavity containing a reflective air space. Figures 12.6 and 12.7 contain photographs of a rotating hot box facility in operation at the Oak Ridge National Laboratory in Oak Ridge, TN, USA. The hot box is positioned for a horizontal heat flow measurement. Figure 12.7 shows the two parts of the hot box separated for insertion of a building element for testing. An apparatus of this type was used to generate the collection of thermal resistance values mentioned in previous sections. Relatively small test specimens that include a reflective air space can be evaluated using a heat-flow meter apparatus. The apparatus pictured in Fig. 12.8 can be used to test a 600 ¥ 600 mm specimen up to about 150 mm thick with heat-flow up or down. This type of measurement, however, is usually
© Woodhead Publishing Limited, 2010
314
Materials for energy efficiency and thermal comfort in buildings
12.6 A rotatable hot box positioned for horizontal heat flow (photo courtesy of the BTRIC, Oak Ridge National Laboratory, USA).
12.7 Hot box apparatus with sides parted to install test specimen (photo courtesy of the BTRIC, Oak Ridge National Laboratory, USA).
© Woodhead Publishing Limited, 2010
Reflective materials and radiant barriers for insulation
315
12.8 Heat-flow meter apparatus with door closed for test.
limited to air gaps less than 50 mm. Smaller versions of the heat-flow meter apparatus have been mounted in a frame and rotated for horizontal heat flow measurements. Kanade and Yarbrough describe this type of measurement which is limited to small specimens that do not include framing or other types of obstructions [4]. Laboratory equipment of the type shown in Figures 12.6,12.7, and 12.8 is not used to evaluate radiant barriers. A large-scale facility that can be used to evaluate attic radiant barriers is shown in Fig. 12.9. The test specimen in Fig. 12.9 is a flat rectangular element. A small enclosed attic with pitched roof can be mounted in the frame and tested under a variety of conditions. The apparatus pictured in Fig. 12.9 operates as a hot box facility. The usefulness of this apparatus is enhanced by the fact that specimens with nonrectangular shapes can be tested (a specimen with triangular cross-section, for example). The type of data that can be obtained from the apparatus in Fig. 12.9 is like that obtained with the conventional hot box. R-values for specific layers within the test element and overall heat transfer coefficients are determined using Eq. 12.7 with DT being the measured temperature difference across the element to be evaluated. The heat flux across the specimen is the same at all locations when steady-state conditions are achieved.
12.5
Codes and standards
Reflective insulation and radiant barrier products are subject to a variety of codes and standards around the world. Primary consideration is given
© Woodhead Publishing Limited, 2010
316
Materials for energy efficiency and thermal comfort in buildings
12.9 Test element installed in the large scale climate simulator (photo courtesy of the BTRIC, Oak Ridge National Laboratory, USA).
to thermal performance evaluations including the measurement of the key physical property – thermal emittance. In addition, properties such as water vapor transmission, resistance to bleeding and delamination, resistance to fungal growth, combustion properties, and tear strength are examples of additional product requirements. Table 12.5 lists standards and specifications that are used in various parts of the world. The standards in Table 12.5 will guide the reader to test methods and computational methods for evaluating reflective insulations and radiant barriers.
12.6
Sources of further information and advice
There is a vast literature associated with reflective insulations and radiant barriers. The literature includes handbook information and published research papers. A representative collection of available material is listed below. Literature reviews ASHRAE Transactions 95 (Part 2) 1989 by W. P. Goss and R. G. Miller ‘Literature Review of Measurement and Predictions of Reflective Insulation System Performance, 1900–1989’. Oak Ridge National Laboratory ORNL/TM-8891 by D. W. Yarbrough ‘Assessment of Reflective Insulations for Residential and Commercial Applications’. © Woodhead Publishing Limited, 2010
Reflective materials and radiant barriers for insulation
317
Table 12.5 Standards and specifications related to reflective products Identification
Title
ISO 6946
Building components and building elements – Thermal resistance and thermal transmittance – Calculation method (Versions of this document exist for individual countries) Common understanding of assessment procedure: products with radiant heat reflective component for use in thermal insulation systems of building envelopes Standard practice for installation and use of reflective insulation in building constructions Standard specification for reflective insulation for building applications Standard practice for installation and use of radiant barrier systems in building construction Standard specification for sheet radiant barriers for building construction applications Standard practice for evaluation of heat gain or loss through ceilings under attics containing radiant barriers by use of a computer program Methods of determining the total thermal resistance of parts of buildings Materials for the thermal insulation of buildings: General criteria and technical provisions Acceptance criteria for reflective foil insulation
CUAP
ASTM C 727 ASTM C 1224 ASTM C 1158 ASTM C 1313 ASTM C 1340
NZS 4214:2006 AS/NZS 4859 ICC-ES AC02 ISO ASTM NZS AS/NZS ICC-ES
International standards organization American society for testing and materials New Zealand standard Joint Australian/New Zealand standard International code council-evaluation services
Reference books Heat Insulation, John Wiley and Sons, New York, Chapter 6 ‘Reflective Insulation’ by G. B. Wilkes (1950). Her Majesty’s Stationery Office 1955 by G. D. Nash, J. Comrie, and H. F. Broughton The Thermal Insulation of Buildings – Design Data and How to Use. ASHRAE Handbook of Fundamentals (2005) Chapter 25 (American Society of Heating, Refrigerating and Air-Conditioning Engineers). Papers with collections of data, derivations or correlations H. E. Robinson and F. J. Powell, ‘The Thermal Insulation Value of Airspaces’, Housing Research Paper 32, National Bureau of Standards Project ME12, USA (1956). Andre O. Desjarlais and David W. Yarbrough, ‘Prediction of the Thermal
© Woodhead Publishing Limited, 2010
318
Materials for energy efficiency and thermal comfort in buildings
Performance of Single and Multi-Airspace Reflective Insulation Materials’, ASTM STP 1116 (1991) pp. 24–49. F. B. Rowley and A. B. Algren, ‘Thermal Resistance of Air Spaces’, Transactions of the American Society of Heating and Ventilating Engineers, 35, 165–191 (1929). M. Hollingsworth, ‘Experimental Testing of Reflective Insulations’, ASTM STP 922 (1987) pp. 506–517. K. G. T. Hollands, T. E. Unny, G. D. Raithby, and L. Konicek, ‘Free Convection Heat Transfer across Inclined Air Layers’, J. of Heat Transfer (May 1976) pp. 189–193. Leon R. Glicksman, ‘Two-Dimensional Heat Transfer Effects on Vacuum and Reflective Insulations’, J. of Thermal Insulation, 14, 281–294 (1991). Joe C. Cook Jr., D. W. Yarbrough, and K. E. Wilkes, ‘Contamination of Reflective Foils in Horizontal Applications and the Effect on Thermal Performance’, ASHRAE Transactions, 95(2), 677–681 (1989).
12.7
References
1. D. C. Cook Jr., D. W. Yarbrough and K. E. Wilkes, ‘Contamination of Reflective Foils in Horizontal Applications and the Effect on Thermal Performance’, ASHRAE Transactions 1989, volume 95, Part 2, 677–681. 2. H. E. Robinson and F. J. Powell, ‘The Thermal Insulation Value of Airspaces’, Housing Research Paper 32, National Bureau of Standards Project ME-12, USA (1956). 3. Andre O. Desjarlais and David W. Yarbrough, ‘Prediction of the Thermal Performance of Single and Multi-Airspace Reflective Insulation Materials’, ASTM STP 1116 (1991) pp. 24–49. 4. P. Kanade and David W. Yarbrough, ‘Use of a Heat-Flow Meter Apparatus to Evaluate Reflective Insulation Systems’, Proc. of the International Conference on Thermal Insulation, 16, 89–109 (2002).
© Woodhead Publishing Limited, 2010
13
Aerogel materials for insulation in buildings
C. - H. Y u, Q. J. F u and S.C.E. T s a n g, University of Oxford, UK
Abstract: Aerogel materials have recently received much attention since they give many exciting applications in a wide range of areas. This chapter highlights the processing of these materials, the resulting physicochemical properties and their applications. Thus, fundamental understandings in the techniques for processing of aerogel materials including conventional drying, supercritical drying, freeze-drying, ambient-pressure drying with regards to material density and void size distribution, thermal conductivity, optical and acoustic properties are provided. In addition, a number of chemical posttreatments for surface engineering of aerogel materials are included. Finally, potentially new applications of using these materials as thermal insulation for building, optical sensor, space dust collector and catalysis are discussed. Key words: silica, aerogel, pore structure, surface, sol-gel process, application.
13.1
Introduction
13.1.1 General properties Aerogels have received significant attention over the last few decades because they possess many unique and characteristic physicochemical properties. For example, solid aerogel can be fabricated at a lower density than any other solid materials, with a density ranging from 1.5 to 50 mg/cm3. It also gives exceptionally low thermal insulation, in the order of 0.005 W/mK, high dielectric constant, at 3–40 GHz with k = 1.008–2.27, low acoustic properties (sound velocities as low as 100 m/s) and good optical transmittance, over 90% even at 632.8 nm (Fricke and Emmerling, 1992; Kim and Hyun, 2001; Schultz et al., 2005, Dorcheh and Abbasi, 2008). Its extraordinarily high specific surface area, corresponding to a high surface-to-volume ratio, is particularly significant. Recent commercial applications of aerogels include thermal window insulation (Duer and Svendsen, 1998; Wagh and Ingale, 2002), supercapacitors (Gouerec et al., 1999; Li et al., 2006), acoustic barriers (Vicente et al., 2005; Gronauer and Fricke, 1986), and catalysis (Pajonk, 1991; Cao et al., 2007; Schneider and Baiker, 1995). A number of possible new applications, such as modified materials for wall decoration, nuclear waste storage (Reynes et 319 © Woodhead Publishing Limited, 2010
320
Materials for energy efficiency and thermal comfort in buildings
al., 2001), adsorbents (Carraher, 2005; Han et al., 2000) and dust capture (Tsou, 1995; Burchell et al., 2006) have been described. Modifying functional groups on the gel surface to carry foreign materials (Yu et al., 2009; Tsang et al., 2006) and total encapsulation of a range of different chemical species in the gel (Maury et al., 2004; Buisson et al., 2001; Orcaire et al., 2006; Yu et al., 2009) could offer new uses in many areas. Thus the range of technologies using aerogels is expanding rapidly to meet new and changing industrial demand.
13.1.2 Background We start by defining terms related to the sol-gel process that will be used throughout this chapter. In a sol, (seed) colloidal particles with diameters in the range of 1–1000 nm are dispersed in a liquid. A gel consists of a sponge-like, three-dimensional solid network whose pores are filled with liquid. When gels are prepared by hydrolysis and condensation of metal or semi-metal alkoxides or other hydrolyzable metal compounds (through the sol stage), the liquid in the pores consists mainly of water and/or alcohols. The resulting wet gels are therefore called aquagels, hydrogels, or alcogels. When the pore liquid is replaced by air without decisively altering the network structure or the volume of the gel body, aerogels are obtained (or cryogels, when the pore liquid is removed by freeze-drying). A xerogel is formed upon conventional drying of wet gels, that is, by increase in temperature or decrease in pressure, and is accompanied by large shrinkage (and mostly destruction) of the initially uniform gel body. Thus the general term ‘aerogel’ describes a high surface area solid material with an internal structure of pores and networks that were originally filled with liquid during synthesis but this has since been replaced with air. Aerogel was first discovered by the scientist Samuel S. Kistler in the late 1920s. Its characteristic properties have been revealed gradually since the initial synthesis (Kistler, 1931, 1932, 1935). Kistler’s work led to many other new and fascinating materials of different composition being developed along the same lines. The first recorded commercial silica aerogel was produced by the Monsanto Chemical Co. at Boston, MA, in the 1940s (Ayers, 2000). Synthesis of aerogel involves three steps: sol and gel formation, aging of the gel and solvent drying. This creates the internal porous structure, which gives the material its characteristic properties. The pores consist of cavities, voids, channels, holes or interstices which can be arranged regularly, similar to zeolite, or mesoporous and molecular sieves. However, aerogels more commonly have a rather irregular porous structure, as the different parameters of the chemical processes in seeding, aging and drying damage the internal ordering structure of the pores. Since the physical and chemical properties are greatly dependent on the conformation of pores, including
© Woodhead Publishing Limited, 2010
Aerogel materials for insulation in buildings
321
pore size, shape, porosity, and density, etc., controlling the size and shape of the pores and their network is a major challenge. The drying process is undoubtedly the most important step affecting the internal porous structure of the final aerogel material. The gel typically shrinks during drying. Many researchers have devoted their efforts to investigating mild drying techniques in ambient pressure in order to maintain the porous network (Schwertfeger et al., 1998; Prakash et al., 1995; Rao et al., 2007; Shi et al., 2006). In recent studies, modifications of surface functional groups, solvent exchange and use of different precursors (Schwertfeger et al., 1998) have been explored as methods to maintain or improve the porosity of aerogels rather than using expensive and cumbersome supercritical techniques. In this chapter, we first review the general synthesis of sol-gel materials and then discuss aerogel synthesis in order to elucidate the key parameters in controlling the internal porous structure of aerogels. For interested readers, more detailed information is available from the literature (e.g. Dorcheh and Abbasi, 2008; Husing and Schubert, 1998; Pierre and Pajonk, 2002, Pajonk and Venkateswara Rao, 2001).
13.2
Processing material and properties
13.2.1 Sol-gel processing The sol-gel process is a wet-chemical technique which is widely adopted for making high surface area oxide materials. The sol-gel process is composed of three stages: hydrolysis, condensation and drying (see Fig. 13.1). A liquid sol particle (the smallest seed particles in the solvent) is first created by hydrolysis of a chemical precursor, followed by condensation to form a gel. The first precursors used in sol-gel processing were metallic salts MXn,
Sol
Gelation/wet gel
t Ex
Mixing of the precursors
r
ti ac
on
o
o fs
lve
nt
Solid
Evaporation
Am
Start of hydrolysis Polycondensation and condensation of the sol particles/ aging
bie
nt-
pr
es
su
Air
re
dr
yin
g
13.1 A typical scheme for preparing aerogels by sol-gel process and drying processes.
© Woodhead Publishing Limited, 2010
322
Materials for energy efficiency and thermal comfort in buildings
in which a metal M is linked to some number n of anions X. In aqueous solution, the chemical precursors are presented as ionic species in which the metal atoms exist as solvated cations M[H2O]nz+. The reactions to form sol particles and gels comprise hydrolysis reactions, in which H2O groups are replaced with OH– groups (alkaline catalysed reactions, see Eq. 13.1) with the loss of protons, and condensation reactions, which lead to the construction of M–O–M ‘oxo’ bridges with the elimination of water molecules (nucleophilic attack of the metal cation, see Eq. 13.2). Thus, the sol particles gradually condense to form a three-dimensional continuous network (base-catalysed sols). In this stage, the porous gel structure is filled with solvent molecules. A more interconnected, wet gel (or hydrogel) forms during the aging period. During the final step, drying, solvent or liquid is removed from the pores of the wet-gel material. Conventional drying is typically accompanied by large shrinkage in volume. M O
H
+ OH
M O
d-
H
d+
H H O H d–
d+
13.1 M O H + H2O
M O
H H O H
d = 0, Leaving group
nucleophile
H d+
d–
M OH + M OH
M O
M OH 13.2
d+
M O
M
+ H2O
H M O
d–
OH M
To understand particle agglomeration, it is important to appreciate the surface characteristics of the particle and the type of aqueous species surrounding it. In general, zero-charged particles give higher aggregation rates to form larger particles, which up to a critical size may settle as precipitate under gravity. Figure 13.2 shows zero-charge nanoparticles in the liquid phase, which collide with each other and form larger clusters (this is thermodynamically favourable because it reduces the overall surface energy of the system). If each particle
© Woodhead Publishing Limited, 2010
Aerogel materials for insulation in buildings
323
13.2 Uncharged nanoparticles undergo a more rapid coalescence than those of charged particles.
13.3 Electrical double layers can protect colloid particles from aggregation.
carries the same electrical charge, mutual electrostatic repulsion will keep them apart in solution, as shown in Fig. 13.3. Typically, the small silica sol (nanoparticles) synthesized by the sol-gel method at pH 7.4 are in the form of a stable and homogeneous colloid which does not undergo aggregation. This is because of the lower isoelectronic point (pH ~ 2.0) of silica compared to the solvent medium, which renders the particles negatively charged. Particles possessing high charges can induce double layers in an aqueous environment and will remain discrete and well dispersed from each other.
© Woodhead Publishing Limited, 2010
324
Materials for energy efficiency and thermal comfort in buildings
13.2.2 Synthesis and structure of metal alkoxides In core-shell nanoparticle morphology, a core metal particle is protected from oxidation and corrosion by a silica coating (Santra et al., 2001). This structure is becoming more popular, and is created using microemulsion techniques. Hydrolysis and condensation of sol-gel precursors such as silicon alkoxide displace the surfactant molecules in micelle assemblies and produce an ultra-thin porous coating on the core particle at the water/organic interface. This process is based on hydrolysis of precursors such as tetraethoxysilane (TEOS) in the presence of water and catalysts, followed by condensation with surface metal hydroxyls. An M–O–Si chemical linkage is established between surface metal atoms and TEOS, followed by the formation of a three-dimensional network of siloxane bonds (Si–O–Si) with increasing TEOS concentration. Once the precursor has been condensed into a gel, the solvent is removed by drying. It is worth noting that the surfaces of silica gels can have different chemical functionalities, i.e. alkoxides, silanol and siloxane, depending on the preparation procedure, reagents used and posttreatments (see Fig. 13.4).
13.2.3 Possibility for advancement using other alkoxides for aerogels Although silica alkoxide is most commonly used, other metal alkoxides (M-OR) can be used for the sol-gel process. For example, titanium, zirconium, tin, carbon and aluminium can be prepared in a similar way to give porous microstructures (Sanchez and Ribot, 1994). The rates of hydrolysis and condensation for these metal alkoxides are much faster than those for silicon as they are much stronger electrophiles. Carbon aerogels can be prepared from pyrolysis of an organic matrix. The surface area of synthesized carbon aerogels ranges from 400 to 800 m2g–1. The pore size distribution is found to depend on the density of the carbon aerogel (Zhang et al., 1999). Carbon aerogel made using the pyrolysis process has been shown to have the largest specific area at 600 °C. After further pyrolysis at 2100 °C, the internal structure revealed by small-angle X-ray scattering (SAXS) contained a large amount of micropores (Reichenauer et al., 1998). Carbon aerogels also show
Si
OR
Alkoxide
Si
OH
Silanol
Si
O
Siloxane
13.4 Silicon–oxygen groups.
© Woodhead Publishing Limited, 2010
Si
Aerogel materials for insulation in buildings
325
density-dependent electrical conductivity, rendering them suitable for use as supercapacitors. They also find use as solar energy collectors because of their lower reflectance of radiation. Alumina aerogel is synthesized using either Al(OsBu) 3 (ASB) or Al(OtBu)3(ATB) as a precursor (Husing and Schubert, 1998). These aerogels can be doped with metallic promoter(s) to introduce new physiochemical properties. For example, Kwak et al. (2005) used a platinum–cobalt–alumina aerogel for the selective oxidation of carbon monoxide to carbon dioxide in hydrogen gas. Controlling the homogeneity of zirconia silica aerogel was demonstrated by Miller et al. (1994). Aerogels based on titania–silica and MTiO2 (M=Mg, Mn, Fe, Co, Zn) were tested as catalysts for photocatalysis (Cao et al., 2007; Ahmed and Attia, 1995; Kapoor et al., 2005). Zirconia aerogels were prepared using combined alcohothermal and supercritical fluid drying techniques, resulting in materials that were characterized by mesopores with a narrow pore size distribution and high specific area (Cao et al., 2002).
13.3
Aerogel formation
13.3.1 Drying techniques Making aerogels requires an efficient drying stage to replace trapped solvent molecules in the wet sol-gel materials with air without damaging the internal porous structure. The drying process is very complex, involving interplays between surface tension, capillarity and diffusion of the solvent with different pore size, shape and wall materials. When liquid is evaporated from occupied pores, it diffuses from the interior of the pore to the outer surface. A cohesion force holds the liquid molecules together (reflected by the phenomenon of surface tension), and adhesion forces stick the liquid molecules to the wall material. If different sizes of pores are present, the larger pores retain solvent molecules less easily than the smaller ones due to the smaller capillary potential under the same pressure conditions. The change in capillary force and the stress created on the wall of the pore are also different when solvent molecules leave the pore structure. A smaller pore network can become brittle, leading to cracking (see Fig. 13.5), since the capillary potential is inversely related to pore radius. Dynamic drying processes also affect the degree of shrinkage. A more rapid evaporation of solvent molecules from the interior pore surface will cause a greater pressure gradient change, which can easily lead to cracks in the pore structure. Thus, the large shrinkage of a gel body upon evaporation of the pore liquid is caused mainly by capillary forces acting on the pore walls as the liquid retreats into the gel body. This results in the collapse of the filigrane, the highly porous inorganic networks of aquagels and alcogels.
© Woodhead Publishing Limited, 2010
326
Materials for energy efficiency and thermal comfort in buildings Pores
Network
Pore liquid
Differential crack
13.5 Evaporation of solvent molecules from smaller pores induces more structural damage (crack) than larger ones.
During the conventional drying process, there are also chemical changes that affect the degree of shrinkage of the aerogel materials. For example, the inner wall surface of a pore is likely to be covered with –OH groups after wet chemical synthesis. In the case of silica gel, the surface Si–OH groups in close proximity can interact with each other to form siloxane bridges during drying. Thus, the porous network will become stiffer, with a smaller pore radius. Elevated temperatures will speed up these chemical changes. When the stress due to solvent evaporation is no longer capable of further deforming the network, the structure may collapse, creating substantial shrinkage in the gel material.
13.3.2 Supercritical drying Supercritical drying is a very efficient method for producing aerogel. Two supercritical drying techniques have been demonstrated. One is described as high temperature supercritical drying (HTSCD) and the other low temperature supercritical drying (LTSCD). HTSCD was the first technique employed in the synthesis of silica aerogel by Kistler in the 1930s and is still widely used to prepare aerogel materials today (see Fig. 13.6). The drying principle is illustrated in Fig. 13.6, which shows a critical point in the phase diagram of a fluid at which the density
© Woodhead Publishing Limited, 2010
Aerogel materials for insulation in buildings
327
Supercritical point Pc
A B P
C
T
Tc
13.6 Schematic to illustrate the principle of supercritical drying.
of its gas and liquid forms is identical. A wet gel containing a large amount of solvent (e.g. methanol, ethanol, acetone, 2-propanol, or water) is first placed in an autoclave, and the temperature and pressure of the container are slowly increased to above the critical point of the solvent (Step A). The drying conditions are kept constant and this allows homogeneous extraction of the solvent because, at the supercritical drying stage, there is no interface between gas and liquid. Thus, the pressure/stress change imposed on the pore structure due to removal of solvent is not significant. The next step, B, is to slowly vent the contents of the autoclave at constant temperature until it reaches ambient pressure. The final step, C, is to decrease the temperature to room temperature, yielding a dried aerogel. However, the supercritical states of most alcohols and acetones are characterized by critical temperatures about 250 °C and critical pressures between 5 and 8 MPa. It is important to note that the combination of high temperature and high pressure could cause undesirable chemical reactions or rearrangements in the surface of the gel network. Kocon et al. (1998) therefore studied the effect of pH on silica aerogel in an attempt to minimize material shrinkage during supercritical drying of ethanol from the structure. Under these conditions, a low density aerogel (3 kg/m3) can be obtained. Gross et al. (1998) used a rapid supercritical drying process to produce silica aerogel
© Woodhead Publishing Limited, 2010
328
Materials for energy efficiency and thermal comfort in buildings
from tetramethoxysilane (TMOS) with ammonia mixed in alcohol. This process involved loading the sol in a stainless steel autoclave and immediately heating the mixture to supercritical conditions. The aging process took place and the reaction rate was very fast due to the high temperature. Once the supercritical point of the alcohol was reached, the supercritical fluid was vented rapidly. The whole process lasted less than one hour (Gross et al., 1998). An advantage of this technique is that the process is carried out in one single step, and a short period of time means an increase in production volume. The disadvantage is that this technique may still induce chemical change in the material due to the high temperature and pressure, but the fast supercritical drying stage may reduce undesirable chemical change to some extent (Poco et al., 1996; Scherer et al., 2002; Gauthier et al., 2004). Another supercritical drying technique is the employment of carbon dioxide (LTSCD) for solvent extraction (Tang and Wang, 2005; Sui et al., 2004). The advantage of this method is that it takes place near to room temperature (< 32 °C) and under moderate pressure (< 80 bar). Figure 13.7 shows the phase diagram of carbon dioxide. A wet gel is placed in an autoclave and carbon dioxide is pumped in. The temperature is then raised to 40 °C and the pressure is kept at about 100 bars to reach the supercritical state of carbon dioxide. The time required for exchanging the trapped solvent with carbon dioxide depends on the dimension of the pores in the gel material. After extraction, the pressure of the applied carbon dioxide is slowly reduced and the temperature is dropped to room temperature. The fluid is then vented from
B
Supercritical carbon dioxide
Pc
A
C
P D
T
Tc
13.7 Schematic illustrating principle of supercritical drying at the lower temperature using carbon dioxide.
© Woodhead Publishing Limited, 2010
Aerogel materials for insulation in buildings
329
the autoclave. Repeated extractions in the same manner are carried out. Silica aerogel can be obtained using this technique (Dorcheh and Abbasi, 2008). Since water and carbon dioxide are rather immiscible, modifier(s) such as alcohols are required to produce highly porous silica aerogels (Husing and Schubert, 1998).
13.3.3 Freeze-drying process Freeze-drying is another mild drying method used to produce aerogels. The liquid solvent in the pores is rapidly frozen and then sublimed under reduced pressure. Using this drying method for the preparation of carbon or TiO2 aerogel materials is well documented (Mukai et al., 2004; Babic et al., 2004; Xu and Yang, 2003; Yamamoto et al., 2002). There are some prerequisite conditions that have to be achieved before the drying process can begin. First, the porous network of the wet material has to be extensively strengthened during the aging period. Secondly, the trapped solvent must have a low sublimation temperature, otherwise it will have to be exchanged with another solvent with lower sublimation temperature to facilitate diffusion and sublimation during drying. Salt or modifier may be used to lower the solvent freezing temperature. Maintaining the integrity of the porous network of a gel is challenging during crystallization of solvent molecules in the pores. The aerogel produced using this method is also known as ‘cryogel’.
13.3.4 Ambient-pressure drying process (APD) Another common drying method in aerogel production is known as ‘ambientpressure drying’ (APD). The drying is carried out at ambient pressure preferably using reduced or elevated pressures. As a potentially cheap and safe drying process for large-scale production of aerogels, this method has received considerable attention from industry. However, reducing shrinkage of the material during the drying process is a significant challenge, and the porous network has to be strengthened considerably, probably through surface modification, prior to drying. In addition, the contact angle between the trapped solvent and the pore wall must be measured to decide whether chemical modification of the inner surface is needed in order to minimize the change in capillary forces following solvent removal (Dorcheh and Abbasi, 2008). The general method for chemical modification of the surface is to use a mixture of precursors before gelation, although modifying the surface after gelation by using silylating agents is also effective. As the silylation reaction commonly takes place in an organic solvent, multi-step processes for solvent exchange are sometimes necessary. For example, mixed water and alcohol is used as a bulk solvent to exchange the trapped water in the gel pores before the silanol group on the surface is silylated by adding a
© Woodhead Publishing Limited, 2010
330
Materials for energy efficiency and thermal comfort in buildings
1 –R
O–Si–R2 –R 3
1
–R
OH
–R3
OH
–R
R2 i– –S –R3 O
–R1
O–Si–R2 –R 1
O –S –R1 i– R2
H
O
H
O
CTMS or HMDZ
O– R1 Si – –R 2
O–Si–R2 –R 1
R2 i– –S –R3 O
H
H
Silylation
–R3
O–Si–R2 –R 3
O
–R1
O
3
OH
–R
OH
modifier (e.g. CTMS, HMDS, HMDZ or others) (see Fig. 13.8). After the surface reaction, the material becomes hydrophobic due to the presence of surface capping groups (Si–O–R). Multi-stepped exchange processes also require long pre-treatment time and large amounts of solvents, which causes economic and environmental concerns. Ambient-pressure drying still results in a degree of material shrinkage, because severe stress is created in the gel material due to the unavoidable pore narrowing with the formation of siloxane. The pore structure can be returned to its original form upon re-wetting under defined conditions, the so-called spring-back effect (Lee et al., 2002) (see Fig. 13.9). Schwertfeger et al. (1998) presented a competitive method using inexpensive waterglass, a simple exchange solvent technique, and drying in ambient pressure with modification of the internal surface. They employed hexamethyldisiloxane (HMDSO)/trimethylchlorosilane (TMCS) solution to modify the inner surface of the wet gel. IPA/TMCS/n-hexane solution was used to prepare a silica aerogel by Kim and Hyun (2003) and Lee et al. (2002). Rao et al. (2005b)
3
13.8 A typical surface silylating process on aerogel by chlorotrimethylsilane (CTMS) or hexamethyldisilazane (HMDZ).
Springback
Springback
Dried gel
Aerogel
13.9 Demonstration of a ‘spring-back effective’ gel. Reproduced with the permission of Elsevier BV.
© Woodhead Publishing Limited, 2010
Aerogel materials for insulation in buildings
331
developed a two-step drying process at ambient pressure applicable to various solvents, including hexane, cyclohexane, heptane, benzene, toluene and xylene. They prepared aerogel from TEOS and modified the surface with hexamethyldisilazane (HMDZ) in different solvents. They reported that heptane gave highly transparent, porous but low density, low thermal conductive and hydrophobic aerogels. FTIR spectra of their pre-treated aerogels clearly indicated the change in surface functionalities (the IR bands at 1600 and 3500 cm–1 corresponding to Si–OH and H–OH were substantially attenuated but new bands at 840 and 1250 cm–1, corresponding to Si–C and C–H were formed (Rao et al., 2005a)).
13.3.5 Controlling density and void size distribution When a wet gel is dried by removing trapped solvent molecules, an inherent porous structure can be reclaimed. In the case of inorganic gel, the skeletal structure becomes more rigid during solvent evaporation. Liquid in the pores is removed to form an extensive porous network. However, heat treatment will concomitantly cause the porous structure to collapse, making the network more dense. The chemical reactions that take place during heat treatment occasionally isolate the pore structure, resulting in closed pores. It is important to avoid cracking and pore blockage in order to maintain an ordered porous structure in an aerogel. A sharp void size distribution can be obtained by adding reagents such as formamide, oxalic acid or glycerol to the gel precursors. The size of macroporous silica aerogel can be tailored by tuning the concentration of polymer added. For example, Nakanishi et al. (1998) successfully prepared a narrow void distributed aerogel by adding polyethylene glycol (PEG) to their sol precursor. A high concentration of PEG improved the strength of the solid matrix, whereas low concentrations of PEG reduced its strength. Harreld et al. (2002) modified silica gels by exchanging a mixture of solvents in order to reduce structural shrinkage during drying at ambient pressure. The porosity, pore size distribution and surface area of their gels were much improved by using appropriate ratios of acetone/alkane. Tabata et al. (2005) dried an alcogel (less shrinkage than aerogel) at ambient temperature to produce an extremely low density gel material of 9 kg/m 3, which corresponded to a reflect index of 1.002. The world’s lowest density silica aerogel was prepared by Larry Hrubesh at Lawrence Livermore National Laboratory (LLNL) in the late 1980s. The claimed density of the aerogel was 3 kg/m3, which is approximately only three times that of air (Arlon and Michael, 2004). Widenmeyer and Anwander (2002) used surfactants ([CH3(CH2)nNMe2(CH2)mNMe2(CH2)nCH3]2+2Br–) of different chain lengths under hydrothermal methods at pH > 9 to prepare tuneable pore sizes and highly ordered cubic mesoporous silicas (MCM-48). Kim and Ryoo (1999)
© Woodhead Publishing Limited, 2010
332
Materials for energy efficiency and thermal comfort in buildings
prepared tuneable pore sizes of cubic mesoporous silica SBA-1 under acidic conditions using tetraethyl orthosilicate and hexadecyltriethylammonium bromide. The pore diameter of the SBA-1 materials was controlled over 1.4–2.7 nm by tuning the surfactant concentration. Rao et al. (2003) used methyltrimethoxysilane (MTMS) precursor, methanol (MeOH) solvent and ammonium hydroxide (NH4OH) catalyst to prepare aerogels. The optimum reagent ratio was obtained to yield a low density but highest contact angle (~173°) aerogel. BET is the most common method for characterizing porosity, pore size distribution and surface area of a synthesized aerogel.
13.4
Physical properties of aerogels
13.4.1 Thermal conductivity Kistler was the first researcher to discuss the low thermal conductivity of silica aerogel (Kistler, 1932, 1935). This led to a fundamental analysis of the factors affecting the overall thermal transportation of aerogels consisting of gas phase, solid phase and radiation components. Figure 13.10 shows a model of the thermal transportation properties of an aerogel as a function of density (Husing and Schubert, 1998). There is a sharp increase in conductivity when the density of the gel material is raised. However, gas and radiation 0.02
Total
Solid
0.01 l/w m–1 K–1
Gas Radiation 0 50
150 r/kg m
250
350
–3
13.10 Thermal conductivity of aerogels: total, solid, gas and radiation transport l, are dependent on the density r of aerogel materials (Husing and Schubert, 1998; Fricke, 1988).
© Woodhead Publishing Limited, 2010
Aerogel materials for insulation in buildings
333
components show the opposite trend for thermal conductivity with increasing density. Thus, the lowest overall thermal conductivity peaks should be minimized at a density of about 150 kg/m3. It was anticipated that smaller pore size played an important role in lowering gaseous thermal conductivity due to the Knudsen effect (Pierre and Pajonk, 2002), and that gas thermal conductivity could be further minimized under reduced pressure. This led to the production of a new silica aerogel which showed thermal conductivity as low as 0.020 W/mK at ambient pressure, with a further decrease to 0.010 W/mK under vacuum at 300 K (Husing and Schubert, 1998; Fricke, 1988). Thermal conductivity also relates to the nature of the porous structure: whether the pores are closed or open will give different thermal transport properties. Heat transport through infrared radiation is an important factor affecting the thermal conductivity of silica aerogels. This is affected by density, temperature and optical thickness. Reducing thermal conductivity by doping aerogels with infrared opacifiers such as carbon or TiO2 is well documented (Husing and Schubert, 1998). Silica aerogels show the lowest thermal conductivity of all non-flammable solid materials (see Fig. 13.11), thus they can be used as a coating to modify construction materials. Aerogels can be used to coat the walls of buildings. The poor infrared radiation prevents heat from a heated room penetrating outside, but visible and UV radiations from external daylight can pass through the material. Aerogels are therefore used for window insulation, daylight windows (for example car windshields, or bathroom, staircase or 45 40 35
l/mW m–1 K–1
30 25 20 15 10 5 0 Aerogel PUR/CFC Air
EPS XPS CFC
Mineral- wool
PUR/CO2
13.11 Comparing thermal conductivity of aerogel with other commercially available materials. PUR: polyurethane foam, CFC: chlorofluorohydrocarbons; EPS, XPS: expanded and extruded polystyrene (Husing & Schubert, 1998).
© Woodhead Publishing Limited, 2010
334
Materials for energy efficiency and thermal comfort in buildings
ceiling windows) and cooling and heating storage applications (Husing and Schubert, 1998; Pierre and Pajonk, 2002). Solar energy can be captured by panelling house walls (see Fig. 13.12), or by solar collectors that use aerogel materials (Fricke et al., 1987; Svendsen, 1992). It is well known that transmitted light suffers from the scatter phenomenon, causing poor optical quality in conventional materials, but significant improvements in the optical quality of aerogels have been reported recently (Duer and Svendsen, 1998). Schultz and co-workers reported a super insulating glazing using a monolithic SiO2 aerogel sheet of approximately 55 × 55 cm2. Anti-reflective treatment of aerogel-coated glass can also improve their visual quality. Solar energy transmittance can reach 76% (Schultz et al., 2005; Jensen et al., 2004).
13.4.2 Optical properties Silica aerogels are between transparent and translucent, depending on their internal structure and moisture content. The porous networks of ordered Shade Outside
Inside
Glass panes
40 °C Wall
Aerogel
20° Insulation
Thermal transport
–15°C
Light-absorbing layer Heat loss
Heat gain
13.12 Principle of energy saving by using aerogel to capture solar energy (Husing and Schubert, 1998).
© Woodhead Publishing Limited, 2010
Aerogel materials for insulation in buildings
335
silica aerogels have smaller structural units than the wavelength of visible light, hence they should appear to be transparent. But if some amorphous structures are introduced in the ordered units, these lead to scattering in the visible light region, known as Rayleigh scattering (De Leo et al., 2001; Tajiri and Igarashi, 1998). Such non-homogeneity in silica aerogel is responsible for reduced transparency, and most silica aerogels appear yellowish under light and bluish under a dark background (Husing and Schubert, 1998). Their optical properties can be tuned by controlling the content of amorphous structures in the aerogel during synthesis. Optical transparency is important for some applications. For example, a new type of solid-state Cerenkov particle detector requires a high quality, transparent aerogel (Adachi et al., 1995). Controlling the processing parameters during synthesis gives arerogels with different degrees of optical transparency. The drying process, degree of water adsorption on Si–OH groups, adsorbed organic components on Si–OCH3 or Si–CH3, heat treatments (Buzykaev et al., 1999), type of precursors, sol-gel process, silation agent and solvent used were all found to affect the optical properties of aerogels (Rao et al., 2001). It was also claimed that two-step synthesis methods give more transparent aerogels than one-step methods, which could be related to the lower degree of amorphous silica present in the aerogel (Rao et al., 2005b; Danilyuk et al., 1999). Supercritical drying of the gel materials with CO2 commonly resulted in materials with better transparency than those dried using other organic fluids. Lower reaction temperature and lower amounts of water appeared to be effective in making aerogels that were more transparent (Husing and Schubert, 1998). Waterglass, a cheap aerogel precursor, gave a low transparency gel, probably because of the presence of large silica particles and sodium ions in the sample.
13.4.3 Acoustic properties Overall, aerogels are excellent acoustic insulators. The acoustic propagation in aerogels depends on the interstitial gas type and pressure, density and, more generally, texture. The sound energy transferred from the gas to the solid phase is partly lost, thus reducing the amplitude and velocity of the acoustic wave. The longitudinal acoustic velocity is typically in the order of 100 m/s. This property makes silica aerogels suitable for applications in acoustic impedance ì/4 matching layers in ultrasonic transducers, range finders, speakers, etc. Their application in house floor-covering and for football pitch sound insulation has been mentioned (Husing and Schubert, 1998). Other applications concern acoustic insulation in transportation and machinery (Gross and Fricke, 1992; Gross et al., 1992). Silica aerogels have also been investigated for applications in anechoic chambers (Pierre and Pajonk, 2002; Forest et al., 1998; Zimmermann et al., 1995).
© Woodhead Publishing Limited, 2010
336
13.5
Materials for energy efficiency and thermal comfort in buildings
Applications of aerogels
13.5.1 Solid state insulation As aerogels have an extraordinarily low thermal conductivity and high acoustic insulation, a striking number of applications have been developed in window glazing (Tewari et al., 1986; Duer and Svendsen, 1998). Reim et al. (2002, 2005) undertook a large programme to develop a highly insulating but translucent glazing material. A sandwich structure construction of gel filled with granules was set up. Krypton gas was used as the filler to optimize thermal insulation. The resulting heat transfer coefficient was less than 0.4 W/mK, with total solar energy transmittance of 35%.
13.5.2 Space applications As low density and lightweight materials, aerogels can successfully capture cosmic dust particles in space. NASA’s stardust (spacecraft) mission programme employed silica aerogels for such capture. The speed of a cosmic dust particle is at least six times that of a bullet. Thus, when a dust particle hits the mechanically rigid silica aerogel, a bullet shaped track can be located in the gel. The extraordinarily lightweight silica aerogel also protects space mirrors (Hrubesh, 1998). The European Recoverable Carrier (EURECA) spacecraft is also using silica aerogel for catching falling cosmic dust (Tsou, 1995). This technology could be expanded to capture gases and dust in buildings and vehicles.
13.5.3 Optical applications Transparent aerogels may find applications in solar windows (Tewari et al., 1986; Rubin and Lampert, 1983; Fricke, 1986), whilst translucent aerogels are proposed for use as solar covers and collectors (Svendsen, 1992; Jensen, 1992). Ultralow density aerogels are currently being considered as lightweight mirror backings (Hotaling, 1993; Hrubesh, 1998). Silica aerogels doped with lanthanides are used as laser glasses (Tillotson et al., 1994). If they are doped with radioactive tritium and a phosphor, radioluminescent light/power sources can be obtained (Ashley et al., 1992). If treated with microwave-energized reducing gases, silica aerogels could become permanent visible photoluminescent sources with emission wavelengths ranging from 460 to 500 nm, due to oxygen-defective centres (Ayers and Hunt, 1997).
13.6
Future trends
Silica aerogels have high surface areas, are highly porous and lightweight but mechanically rigid and will no doubt find a wide range of applications © Woodhead Publishing Limited, 2010
Aerogel materials for insulation in buildings
337
from pharmaceutical to semiconductor industries. Silica aerogels can also be chemically modified to suit specific applications. A popular area of research is seeking applications for silica aerogel in biotechnology. Functionalizing the surface of silica aerogels to carry biomolecules can be divided broadly into two methods. The first method is based on non-covalent binding of bio-species by simple electrostatic interaction. At a pH above the isoelectric point (IEP), the surface of a silica aerogel becomes negatively charged, whereas at a pH below the IEP, the surface is positively charged. If the biomolecule of interest carries the opposite charge to the aerogel in solution, it attaches to the silica surface by electrostatic attraction. The advantage of this method is that it does not require complex processes for chemical binding of the biomolecule, which therefore maintains its original conformation and activity (see Fig. 13.13). The alternative technique is covalent linkage of the biomolecule onto the surface, which provides a much stronger binding affinity and site specificity for the biomolecule attachment. General methods for covalent conjugation of biomolecules with surface functional end groups such as –NH2, –SH, and –COOH are available (see Fig. 13.14). Silica aerogel can therefore carry a wide variety of bio-species following surface modification, including small drug, antigen and protein molecules. After the silica surface is tagged to the bio-species, interesting applications such as in vitro bio-separation and in vivo targeting of cancer cells can be envisaged, and chemical modification of aerogels has been studied intensively over the last decade. El Rassy et al. (2003) have recently tailored the surfaces of aerogels with different degrees of hydrophobicity and hydrophilicity through different coverage of Si–OH, Si–OCH3 or Si–CH3 end groups. Bass and Katz (2006) have prepared silica surfaces with bi-functional groups consisting of thiol and primary amine groups, which were characterized using solid-state UV/Visble, Si-19 CP/MAS NMR and C-13 CP/MAS NMR spectroscopy. Zhang et al. (2008) prepared helical meso-structured silica as a drug carrier. Their report revealed that drug release rate could be controlled by the helicity and morphology of the meso-structured silica. Chandra and Bhaumik (2009)
Silica aerogel
Bio-species
13.13 Schematic to illustrate the formation of non-covalent biospecies conjugates through electrostatic attraction.
© Woodhead Publishing Limited, 2010
338
Materials for energy efficiency and thermal comfort in buildings O
O + NH2 – Biomolecule
NP
C
NP
SH + HO –(CH2)6–S–S– Biomolecule
OH
NP
C
NP
NH
S–S
Biomolecule
Biomolecule
O O NP
NH2 +
N–O–C– Biomolecule
O NP
NH
C
Biomolecule
O
13.14 Schematic representation of covalent bio-conjugation protocols for the attachment of biomolecules on silica nanoparticles (Wang et al., 2006). Reproduced with the permission of American Chemical Society (ACS).
prepared a new functionalized mesoporous polymer with silica for the removal of pollutant anions. For example, mesoporous poly-triallylamine (MPTA-1) showed high anion exchange efficiency for the removal of pollutant anions such as MnO4–, CrO42–, AsO33–, NO3– and PO43–. Attia et al. (1994) prepared alkaline earth oxide modified aerogels for the capture of greenhouse gases such as CO2, SO2 and NOX. The high surface area of silica areogel combined with the basicity of CaO or MgO has proved to be efficient in capture and/ or adsorption of these acidic pollutants. Other smart materials containing silica aerogel, such as silica-coated magnetic nanoparticles (Yu et al., 2007, 2009; Tsang et al., 2006) and luminescent silica aerogels (Fricke, 1992; Ashley et al., 1992; Leventis et al., 1999) have been described. Heavy metals have been removed from industrial effluents using novel magnetic nanocomposites synthesized by embedding metal nanoparticles in a silica aerogel (Xu and Dong, 2008). Applications of these materials in capturing hazardous substances from water have been demonstrated (Bryant et al., 2003; Wingenfelder et al., 2005; Perez-Quintanilla et al., 2006). The possible applications of these smart and related materials to solving current environmental problems have been widely discussed (Zhu et al., 2007; Mureseanu et al., 2008; Puanngam and Unob, 2008; Shevchenko et al., 2008; Yantasee et al., 2008). As a result, study on grafting reactive species, including bio-molecules, inorganic catalyst species or composites, onto material surfaces has intensified. New applications, such as developing enzymatic or photo-catalytic paints for wall decorations to remove pollutants (e.g. incorporating photoactive TiO2 and ZnO into aerogels) may become possible in the near future.
© Woodhead Publishing Limited, 2010
Aerogel materials for insulation in buildings
13.7
339
Conclusions
This chapter only gives a limited amount of information on the chemistry and techniques involved in synthesizing aerogels. Many inorganic polymeric oxides are remarkable by themselves, with a very rich chemistry that can be tailored to a wide range of applications in fundamental science and modern technology. Recent developments in the preparation of ‘aerogel-like’ materials at ambient pressure, which eliminates the need to use an autoclave, will open new fields of applications at the industrial level and require further chemical characterization. Organic, inorganic and composite aerogels clearly deserve to be studied as a new class of chemically designed architectures, and much remains to be done for materials other than silica.
13.8
References
Adachi, I., Sumiyoshi, T., Hayashi, K., Iida, N., Enomoto, R., Tsukada, K., Suda, R., Matsumoto, S., Natori, K., Yokoyama, M. & Yokogawa, H. (1995) Study of a threshold Cherenkov counter based on silica aerogels with low refractive-indexes. Nuclear Instruments & Methods in Physics Research Section A – Accelerators Spectrometers Detectors and Associated Equipment, 355, 390–8. Ahmed, M. S. & Attia, Y. A. (1995) Aerogel materials for photocatalytic detoxification of cyanide wastes in water. J. Non-Cryst. Solids, 186, 402–7. Arlon, H. & Michael, A. (2004) SilicaAeroGels. History of Silica Aerogels. Berkeley Lab. Ashley, C. S., Reed, S. T., Brinker, C. J., Walko, R. J., Ellefson, R. E. & Gill, J. T. (1992) Aerogel composites for radioluminescent light/power sources. Chem. Process. Adv. Mater., 989–96. Attia, Y. A., Ahmed, M. S. & Zhu, M. (1994) Sol-gel prepared aerogels for the capture of pollution gases. Sol-Gel Process. Appl., [Proc. Int. Symp. Adv. Sol-Gel Process. Appl.], 311–21. Ayers, M. (2000) The Pioneer: Samuel Kistler. Berkeley Lab. Ayers, M. R. & Hunt, A. J. (1997) Visibly photoluminescent silica aerogels. J. NonCryst. Solids, 217, 229–35. Babic, B., Kaluderovic, B., Vracar, L. & Krstajic, N. (2004) Characterization of carbon cryogel synthesized by sol-gel polycondensation and freeze-drying. Carbon, 42, 2617–24. Bass, J. D. & Katz, A. (2006) Bifunctional surface imprinting of silica: thermolytic synthesis and characterization of discrete thiol-amine functional group pairs. Chem. Mater., 18, 1611–20. Bryant, D. E., Stewart, D. I., Kee, T. P. & Barton, C. S. (2003) Development of a functionalized polymer-coated silica for the removal of uranium from groundwater. Environmental Science & Technology, 37, 4011–16. Buisson, P., Hernandez, C., Pierre, M. & Pierre, A. C. (2001) Encapsulation of lipases in aerogels. J. Non-Cryst. Solids, 285, 295–302. Burchell, M. J., Graham, G. & Kearsley, A. (2006) Cosmic dust collection in aerogel. Annual Review of Earth and Planetary Sciences, 34, 385–418. Buzykaev, A. R., Danilyuk, A. F., Ganzhur, S. F., Kravchenko, E. A. & Onuchin, A. P.
© Woodhead Publishing Limited, 2010
340
Materials for energy efficiency and thermal comfort in buildings
(1999) Measurement of optical parameters of aerogel. Nucl. Instrum. Methods Phys. Res., Sect. A, 433, 396–400. Cao, S., Yeung, K. L. & Yue, P. L. (2007) An investigation of trichloroethylene photocatalytic oxidation on mesoporous titania-silica aerogel catalysts. Applied Catalysis B–Environmental, 76, 64–72. Cao, Y., Hu, J. C., Hong, Z. S., Deng, J. F. & Fan, K. N. (2002) Characterization of high-surface-area zirconia aerogel synthesized from combined alcohothermal and supercritical fluid drying techniques. Catalysis Letters, 81, 107–12. Carraher, C. E., Jr. (2005) General topics: silica aerogels – properties and uses. Polym. News, 30, 386–8. Chandra, D. & Bhaumik, A. (2009) A new functionalized mesoporous polymer with high efficiency for the removal of pollutant anions. J. Mater. Chem., 19, 1901–7. Danilyuk, A. F., Kravchenko, E. A., Okunev, A. G., Onuchin, A. P. & Shaurman, S. A. (1999) Synthesis of aerogel tiles with high light scattering length. Nucl. Instrum. Methods Phys. Res., Sect. A, 433, 406–7. De Leo, R., Capozzi, V., Casalino, C., Cisbani, E., Coluzza, C., Frullani, S., Garibaldi, F., Iodice, M., Lagamba, L., Nappi, E., Perna, G. & Urciuoli, G. M. (2001) Chromatic aberration and forward scattering of light in silica aerogel. Nuclear Instruments & Methods in Physics Research Section A – Accelerators Spectrometers Detectors and Associated Equipment, 457, 52–63. Dorcheh, A. S. & Abbasi, M. H. (2008) Silica aerogel; synthesis, properties and characterization. Journal of Materials Processing Technology, 199, 10–26. Duer, K. & Svendsen, S. (1998) Monolithic silica aerogel in superinsulating glazings. Sol. Energy, 63, 259–67. El Rassy, H., Buisson, P., Bouali, B., Perrard, A. & Pierre, A. C. (2003) Surface characterization of silica aerogels with different proportions of hydrophobic groups, dried by the CO2 supercritical method. Langmuir, 19, 358–63. Forest, L., Gibiat, V. & Woignier, T. (1998) Biot’s theory of acoustic propagation in porous media applied to aerogels and alcogels. J. Non-Cryst. Solids, 225, 287–92. Fricke, J. (1986) Thermal transport in porous superinsulations. Springer Proc. Phys., 6, 94–103. Fricke, J. (1988) Aerogels. Scientific American, 258, 92. Fricke, J. (1992) Aerogels and their Applications. J. Non-Cryst. Solids, 147, 356–62. Fricke, J. & Emmerling, A. (1992) Aerogels. J. Am. Ceram. Soc., 75, 2027–36. Fricke, J., Caps, R., Buttner, D., Heinemann, U., Hummer, E. & Kadur, A. (1987) Thermal loss coefficients of monolithic and antigranulocytes aerogel systems. Sol. Energy Mater., 16, 267–74. Gauthier, B. M., Bakrania, S. D., Anderson, A. M. & Carroll, M. K. (2004) A fast supercritical extraction technique for aerogel fabrication. J. Non-Cryst. Solids, 350, 238–43. Gouerec, P., Miousse, D., Tran-Van, F. & Dao, L. H. (1999) Characterization of pyrolized polyacrylonitrile aerogel thin films used in double-layer supercapacitors. J. New Mater. Electrochem. Syst., 2, 221–6. Gronauer, M. & Fricke, J. (1986) Acoustic properties of microporous silica-aerogel. Acustica, 59, 177–81. Gross, J. & Fricke, J. (1992) Ultrasonic velocity-measurements in silica, carbon and organic aerogels. J. Non-Cryst. Solids, 145, 217–22. Gross, J., Fricke, J. & Hrubesh, L. W. (1992) Sound-propagation in SiO2 aerogels. Journal of the Acoustical Society of America, 91, 2004–6.
© Woodhead Publishing Limited, 2010
Aerogel materials for insulation in buildings
341
Gross, J., Coronado, P. R. & Hrubesh, L. W. (1998) Elastic properties of silica aerogels from a new rapid supercritical extraction process. J. Non-Cryst. Solids, 225, 282–6. Han, S., Sohn, K. & Hyeon, T. (2000) Fabrication of new nanoporous carbons through silica templates and their application to the adsorption of bulky dyes. Chem. Mater., 12, 3337–41. Harreld, J. H., Ebina, T., Tsubo, N. & Stucky, G. (2002) Manipulation of pore size distributions in silica and ormosil gels dried under ambient pressure conditions. J. Non-Cryst. Solids, 298, 241–51. Hotaling, S. P. (1993) Ultra-low density aerogel optical applications. J. Mater. Res., 8, 352–5. Hrubesh, L. W. (1998) Aerogel applications. J. Non-Cryst. Solids, 225, 335–42. Husing, N. & Schubert, U. (1998) Aerogels – airy materials: chemistry, structure, and properties. Angew. Chem., Int. Ed., 37, 22–45. Jensen, K. I. (1992) Passive solar component based on evacuated monolithic silica aerogel. J. Non-Cryst. Solids, 145, 237–9. Jensen, K. I., Schultz, J. M. & Kristiansen, F. H. (2004) Development of windows based on highly insulating aerogel glazings. J. Non-Cryst. Solids, 350, 351–7. Kapoor, P. N., Uma, S., Rodriguez, S. & Klabunde, K. J. (2005) Aerogel processing of MTi2O5 (M = Mg, Mn, Fe, Co, Zn, Sn) compositions using single source precursors: synthesis, characterization and photocatalytic behavior. Journal of Molecular Catalysis A – Chemical, 229, 145–50. Kim, G. S. & Hyun, S. H. (2001) Synthesis and application of nanoporous aerogel. Seramisutu, 4, 5–16. Kim, G. S. & Hyun, S. H. (2003) Effect of mixing on thermal and mechanical properties of aerogel–PVB composites. J. Mater. Sci., 38, 1961–6. Kim, M. J. & Ryoo, R. (1999) Synthesis and pore size control of cubic mesoporous silica SBA-1. Chem. Mater., 11, 487–91. Kistler, S. S. (1931) Coherent expanded aerogels and jellies. Nature (London, U. K.), 127, 741. Kistler, S. S. (1932) Coherent expanded aerogels. J. Phys. Chem., 36, 52–64. Kistler, S. S. (1935) The relation between heat conductivity and structure in silica aerogel. J. Phys. Chem., 39, 79–85. Kocon, L., Despetis, F. & Phalippou, J. (1998) Ultralow density silica aerogels by alcohol supercritical drying. J. Non-Cryst. Solids, 225, 96–100. Kwak, C., Park, T. J. & Suh, D. J. (2005) Preferential oxidation of carbon monoxide in hydrogen-rich gas over platinum–cobalt–alumina aerogel catalysts. Chemical Engineering Science, 60, 1211–17. Lee, C. J., Kim, G. S. & Hyun, S. H. (2002) Synthesis of silica aerogels from waterglass via new modified ambient drying. J. Mater. Sci., 37, 2237–41. Leventis, N., Elder, I. A., Rolison, D. R., Anderson, M. L. & Merzbacher, C. I. (1999) Durable modification of silica aerogel monoliths with fluorescent 2,7-diazapyrenium moieties. Sensing oxygen near the speed of open-air diffusion. Chem. Mater., 11, 2837–45. Li, J., Wang, X. Y., Huang, Q. H., Gamboa, S. & Sebastian, P. J. (2006) Studies on preparation and performances of carbon aerogel electrodes for the application of supercapacitor. Journal of Power Sources, 158, 784–8. Maury, S., Buisson, P., Perrard, A. & Pierre, A. C. (2004) Influence of the sol-gel chemistry on the activity of a lipase encapsulated in a silica aerogel. Journal of Molecular Catalysis B – Enzymatic, 29, 133–48.
© Woodhead Publishing Limited, 2010
342
Materials for energy efficiency and thermal comfort in buildings
Miller, J. B., Rankin, S. E. & Ko, E. I. (1994) Strategies in controlling the homogeneity of zirconia silica aerogels – effect of preparation on textural and catalytic properties. J. Catal., 148, 673–82. Mukai, S. R., Nishihara, H., Shichi, S. & Tamon, H. (2004) Preparation of porous TiO2 cryogel fibers through unidirectional freezing of hydrogel followed by freeze-drying. Chem. Mater., 16, 4987–91. Mureseanu, M., Reiss, A., Stefanescu, I., David, E., Parvulescu, V., Renard, G. & Hulea, V. (2008) Modified SBA-15 mesoporous silica for heavy metal ions remediation. Chemosphere, 73, 1499–504. Nakanishi, K., Minakuchi, H., Soga, N. & Tanaka, N. (1998) Structure design of doublepore silica and its application to HPLC. J. Sol-Gel Sci. Technol., 13, 163–9. Orcaire, O., Buisson, P. & Pierre, A. C. (2006) Application of silica aerogel encapsulated lipases in the synthesis of biodiesel by transesterification reactions. Journal of Molecular Catalysis B – Enzymatic, 42, 106–13. Pajonk, G. M. (1991) Aerogel catalysts. Applied Catalysis, 72, 217–66. Pajonk, G. M. & Venkateswara Rao, A. (2001) From sol-gel chemistry to the applications of some inorganic and/or organic aerogels. Recent Res. Dev. Non-Cryst. Solids, 1, 1–20. Perez-Quintanilla, D., Del Hierro, I., Fajardo, M. & Sierra, I. (2006) 2-Mercaptothiazoline modified mesoporous silica for mercury removal from aqueous media. Journal of Hazardous Materials, 134, 245–56. Pierre, A. C. & Pajonk, G. M. (2002) Chemistry of aerogels and their applications. Chem. Rev. (Washington, DC, U.S.), 102, 4243–65. Poco, J. F., Coronado, P. R., Pekala, R. W. & Hrubesh, L. W. (1996) A rapid supercritical extraction process for the production of silica aerogels. Mater. Res. Soc. Symp. Proc., 431, 297–302. Prakash, S. S., Brinker, C. J. & Hurd, A. J. (1995) Silica aerogel films at ambient-pressure. J. Non-Cryst. Solids, 190, 264–75. Puanngam, M. & Unob, F. (2008) Preparation and use of chemically modified MCM-41 and silica gel as selective adsorbents for Hg(II) ions. Journal of Hazardous Materials, 154, 578–87. Rao, A. P., Pajonk, G. M. & Rao, A. V. (2005a) Effect of preparation conditions on the physical and hydrophobic properties of two step processed ambient pressure dried silica aerogels. J. Mater. Sci., 40, 3481–9. Rao, A. P., Rao, A. V. & Pajonk, G. M. (2005b) Hydrophobic and physical properties of the 2 step processed ambient pressure dried silica aerogels with various exchanging solvents. J. Sol-Gel Sci. Technol., 36, 285–92. Rao, A. P., Rao, A. V. & Pajonk, G. M. (2007) Hydrophobic and physical properties of the ambient pressure dried silica aerogels with sodium silicate precursor using various surface modification agents. Appl. Surf. Sci., 253, 6032–40. Rao, A. V., Nilsen, E. & Einarsrud, M. A. (2001) Effect of precursors, methylation agents and solvents on the physicochemical properties of silica aerogels prepared by atmospheric pressure drying method. J. Non-Cryst. Solids, 296, 165–71. Rao, A. V., Kulkarni, M. M., Amalnerkar, D. P. & Seth, T. (2003) Superhydrophobic silica aerogels based on methyltrimethoxysilane precursor. J. Non-Cryst. Solids, 330, 187–95. Reichenauer, G., Emmerling, A., Fricke, J. & Pekala, R. W. (1998) Microporosity in carbon aerogels. J. Non-Cryst. Solids, 225, 210–14. Reim, M., Beck, A., Korner, W., Petricevic, R., Glora, M., Weth, M., Schliermann, T.,
© Woodhead Publishing Limited, 2010
Aerogel materials for insulation in buildings
343
Fricke, J., Schmidt, C. & Potter, F. J. (2002) Highly insulating aerogel glazing for solar energy usage. Sol. Energy, 72, 21–9. Reim, M., Korner, W., Manara, J., Korder, S., Arduini-Schuster, M., Ebert, H. P. & Fricke, J. (2005) Silica aerogel granulate material for thermal insulation and daylighting. Sol. Energy, 79, 131–9. Reynes, J., Woignier, T. & Phalippou, J. (2001) Permeability measurement in composite aerogels: application to nuclear waste storage. J. Non-Cryst. Solids, 285, 323–7. Rubin, M. & Lampert, C. M. (1983) Transparent silica aerogels for window insulation. Sol. Energy Mater., 7, 393–400. Sanchez, C. & Ribot, F. (1994) Design of hybrid organic-inorganic materials synthesized via sol-gel chemistry. New Journal of Chemistry, 18, 1007–47. Santra, S., Tapec, R., Theodoropoulou, N., Dobson, J., Hebard, A. & Tan, W. H. (2001) Synthesis and characterization of silica-coated iron oxide nanoparticles in microemulsion: the effect of nonionic surfactants. Langmuir, 17, 2900–6. Scherer, G. W., Gross, J., Hrubesh, L. W. & Coronado, P. R. (2002) Optimization of the rapid supercritical extraction process for aerogels. J. Non-Cryst. Solids, 311, 259–72. Schneider, M. & Baiker, A. (1995) Aerogels in catalysis. Catal. Rev. – Sci. Eng., 37, 515–56. Schultz, J. M., Jensen, K. I. & Kristiansen, F. H. (2005) Super insulating aerogel glazing. Sol. Energy Mater. Sol. Cells, 89, 275–85. Schwertfeger, F., Frank, D. & Schmidt, M. (1998) Hydrophobic waterglass based aerogels without solvent exchange or supercritical drying. J. Non-Cryst. Solids, 225, 24–9. Shevchenko, N., Zaitsev, V. & Walcarius, A. (2008) Bifunctionalized mesoporous silicas for Cr(VI) reduction and concomitant Cr(III) immobilization. Environmental Science & Technology, 42, 6922–8. Shi, F., Wang, L. & Liu, J. (2006) Synthesis and characterization of silica aerogels by a novel fast ambient pressure drying process. Mater. Lett., 60, 3718–22. Sui, R. H., Rizkalla, A. S. & Charpentier, P. A. (2004) Synthesis and formation of silica aerogel particles by a novel sol-gel route in supercritical carbon dioxide. Journal of Physical Chemistry B, 108, 11886–92. Svendsen, S. (1992) Solar collector with monolithic silica aerogel. J. Non-Cryst. Solids, 145, 240–3. Tabata, M., Adachi, I., Fukushima, T., Kawai, H., Kishimoto, H., Kuratani, A., Nakayama, H., Nishida, S., Noguchi, T., Okudaira, K., Tajima, Y., Yano, H., Yokogawa, H. & Yoshida, H. (2005) Development of silica aerogel with any density. 2005 IEEE Nuclear Science Symposium Conference Record, Vols 1–5, 816–18. Tajiri, K. & Igarashi, K. (1998) The effect of the preparation conditions on the optical properties of transparent silica aerogels. Sol. Energy Mater. Sol. Cells, 54, 189–95. Tang, Q. & Wang, T. (2005) Preparation of silica aerogel from rice hull ash by supercritical carbon dioxide drying. J. Supercrit. Fluids, 35, 91–4. Tewari, P. H., Hunt, A. J. & Lofftus, K. D. (1986) Advances in production of transparent silica aerogels for window glazings. Springer Proc. Phys., 6, 31–7. Tillotson, T. M., Sunderland, W. E., Thomas, I. M. & Hrubesh, L. W. (1994) Synthesis of lanthanide and lanthanide-silicate aerogels. J. Sol-Gel Sci. Technol., 1, 241–9. Tsang, S. C., Yu, C. H., Gao, X. & Tam, K. (2006) Silica-encapsulated nanomagnetic particle as a new recoverable biocatalyst carrier. Journal of Physical Chemistry B, 110, 16914–22. Tsou, P. (1995) Silica aerogel captures cosmic dust intact. J. Non-Cryst. Solids, 186, 415–27. © Woodhead Publishing Limited, 2010
344
Materials for energy efficiency and thermal comfort in buildings
Vicente, C. L., Choi, H. C., Xia, J. S., Halperin, W. P., Mulders, N. & Lee, Y. (2005) A-B transition of superfluid He-3 in aerogel and the effect of anisotropic scattering. Physical Review B, 72, 094519. Wagh, P. B. & Ingale, S. V. (2002) Comparison of some physico-chemical properties of hydrophilic and hydrophobic silica aerogels. Ceram. Int., 28, 43–50. Wang, L., Wang, K. M., Santra, S., Zhao, X. J., Hilliard, L. R., Smith, J. E., Wu, J. R. & Tan, W. H. (2006) Watching silica nanoparticles glow in the biological world. Anal Chem, 78, 646–54. Widenmeyer, M. & Anwander, R. (2002) Pore size control of highly ordered mesoporous silica MCM-48. Chem. Mater., 14, 1827–31. Wingenfelder, U., Nowack, B., Furrer, G. & Schulin, R. (2005) Adsorption of Pb and Cd by amine-modified zeolite. Water Research, 39, 3287–97. Xu, J. J. & Yang, J. S. (2003) Nanostructured amorphous manganese oxide cryogel as a high-rate lithium intercalation host. Electrochemistry Communications, 5, 230–5. Xu, Z. & Dong, M. (2008) Synthesis, characterization, and application of magnetic nanocomposites for the removal of heavy metals from industrial effluents. Emerging Environmental Technologies, 105–48. Yamamoto, T., Sugimoto, T., Suzuki, T., Mukai, S. R. & Tamon, H. (2002) Preparation and characterization of carbon cryogel microspheres. Carbon, 40, 1345–51. Yantasee, W., Charnhattakorn, B., Fryxell, G. E., Lin, Y. H., Timchalk, C. & Addleman, R. S. (2008) Detection of Cd, Pb, and Cu in non-pretreated natural waters and urine with thiol functionalized mesoporous silica and Nafion composite electrodes. Anal. Chim. Acta, 620, 55–63. Yu, C. H., Lo, C. C. H., Tam, K. & Tsang, S. C. (2007) Monodisperse binary nanocomposite in silica with enhanced magnetization for magnetic separation. Journal of Physical Chemistry C, 111, 7879–82. Yu, C. H., Al-Saadi, A., Shih, S. J., Qiu, L., Tam, K. Y. & Tsang, S. C. (2009) Immobilization of BSA on silica-coated magnetic iron oxide nanoparticle. Journal of Physical Chemistry C, 113, 537–43. Zhang, L., Qiao, S. Z., Jin, Y. G., Cheng, L. N., Yan, Z. F. & Lu, G. Q. (2008) Hydrophobic functional group initiated helical mesostructured silica for controlled drug release. Advanced Functional Materials, 18, 3834–42. Zhang, S. Q., Wang, J., Shen, J., Deng, Z. S., Lai, Z. Q., Zhou, B., Attia, S. M. & Chen, L. Y. (1999) The investigation of the adsorption character of carbon aerogels. Nanostruct. Mater., 11, 375–81. Zhu, X. B., Chang, X. J., Cui, Y. M., Zou, X. J., Yang, D. & Hu, Z. (2007) Solid-phase extraction of trace Cu(II) Fe(III) and Zn(II) with silica gel modified with curcumin from biological and natural water samples by ICP-OES. Microchemical Journal, 86, 189–94. Zimmermann, A., Gross, J. & Fricke, J. (1995) Constant-Q acoustic attenuation in silica aerogels. J. Non-Cryst. Solids, 186, 238–43.
© Woodhead Publishing Limited, 2010
14
Hygrothermal materials for heat and moisture control in buildings
M. R. H a l l, University of Nottingham, UK
Abstract: This chapter seeks to explain what makes a ‘hygrothermal’ material, with reference to their specific ability to regulate indoor environmental conditions of air temperature and relative humidity. The volume averaged physical properties of these materials is addressed along with the experimental and numerical techniques employed to characterize and study their behaviour. The main material classes of candidate hygrothermal materials are explained in detail. Finally, the application of these materials in relation to buildings is explored along with predicted future research trends in this field. Details of the main active research groups and numerical modelling techniques available are provided for those wishing to engage in the subject. Key words: hygrothermal behaviour, porous materials, humidity buffering, thermal buffering.
14.1 Introduction The balance (or buffering) of indoor air temperature and relative humidity (RH) in buildings is very important from the point of view of respiratory health and comfort of the occupants (Toftum et al., 1998a), healthy skin by avoiding dryness (Toftum et al., 1998b), perceived indoor air quality (Fang et al., 1998a), to avoid deterioration of the building materials (Lucas et al., 2002), and to avoid mould growth and the problems associated with condensation (Sedlbauer, 2002). The use of mechanical systems for heating, cooling, ventilation and air conditioning for air temperature and RH control is not always the best solution due to the levels of energy consumption required, the issue of noise for occupants, the need for regular maintenance, and the potential threats associated with security of energy supply needed to run the equipment.
14.1.1 What makes a material hygrothermal? Hygrothermal behaviour, with respect to materials and buildings, considers the simultaneous (and inter-dependent) occurrence of heat absorption, storage and release, and moisture (liquid/vapour) absorption, storage and release. It is by definition a fully transient approach normally tackled through a combination 345 © Woodhead Publishing Limited, 2010
346
Materials for energy efficiency and thermal comfort in buildings
of experimental testing, physical modelling and numerical modelling solutions, as detailed in Chapter 2. The approach is typically applied to materials such as timber, plasterboard, insulation materials, masonry, concrete, brick, lime plaster, etc., and more recently earth materials. All materials and adjacent control volumes (e.g. a room or zone in a building) can be assessed hygrothermically, but not all exhibit desirable properties for the given application. The ones that do are referred to as ‘hygrothermal materials’ and have good capacity for enthalpy buffering, i.e. simultaneous buffering of heat energy (sensible and latent energy in air) and mass concentration (vapour and associated partial pressure). In order to predicatively model hygrothermal behaviour, knowledge of several material functional properties is required: ∑ dry density ∑ bulk porosity and apparent porosity ∑ dry state and moisture-dependent heat capacity at constant pressure ∑ dry state and moisture-dependent thermal conductivity ∑ sorption isotherms including absorption/desorption moisture storage functions at relevant temperatures ∑ sorptivity (or water absorption coefficient) ∑ vapour permeability ∑ hydraulic conductivity. Much experimental data has been recorded and published for these properties for many conventional and existing materials, though there is much work still to do. The data is included in the databases for various computer software packages as listed in Section 14.6. The key advantages to using hygrothermal materials in buildings include: ∑ ∑ ∑ ∑ ∑ ∑
Increased thermal comfort Increased perceived indoor air quality Reduced ventilation and cooling in summer time Reduced mould formation Reduced dust mite population (asthma trigger) Reduced structural degradation of materials due to moisture.
14.1.2 Buffering capacities Conventionally, we can study thermal (heat) energy buffering and moisture vapour buffering. Both involve absorption, desorption and volumetric storage capacity changing as a function of time in response to driving potentials in the adjacent control volume. For details of the fundamentals behind these processes, refer to Chapter 2. In the case of buildings, the material constitutes
© Woodhead Publishing Limited, 2010
Hygrothermal materials for heat and moisture control
347
a portion of the indoor environment (e.g. walls) and the control volume is an occupied space filled with air containing moisture vapour and other gases. We know that for thermal energy, the driving potentials include the heat energy differential between air and material with heat therefore travelling from the hotter body to the cooler body, e.g. warm air heating a cooler surface. The increase in surface temperature of the material generates a temperature gradient within that material resulting in transfer of heat, principally by conduction. The rate of energy transfer is determined by the thermal conductivity of the material and also the steepness of the temperature gradient. If the material density is high, normally accompanied by a high specific heat capacity, the energy requirement for temperature gradient formation is higher. Hence, if the rate of heat flow is constant from the control volume (assumed steady state) the response time of the material to distribute heat throughout its mass can be given by the thermal diffusivity, a (m2/s), which is simply calculated from l/rcp. Thermal effusivity, b, is the ability of the material to exchange heat with its surroundings (i.e. heat entering or leaving the material) and is given by l r c p . In the same way that ‘thermal mass’ can be used to stabilize the temperature of occupied spaces, hygroscopic materials have a hygric capacity that can be used to buffer relative humidity fluctuations. Excessive humidity can result from activities such as bathing, washing and drying clothes and occupant perspiration, while low humidity is associated with heated spaces in the winter months. Humidity buffering is therefore a desirable property of a material to absorb water vapour from the air, when relative humidity is high, and release this water as vapour when relative humidity falls. This property can be quantified using the experimentally-determined moisture buffer value (MBV) as defined by Rode (2003) and the NORDTEST Project. For this test a sample of material is subjected to a high humidity (23 °C 75% RH) environment for a period of 8 h followed by a low humidity environment (23 °C 33% RH) for 16 h. This cycle is repeated for at least three days and until the change of mass between cycles is less than 5%. Specimens are sealed on all but one exposed surface over which the air velocity should be 0.10 m/s ± 0.05. An example of experimental test data for the MBV test is shown in Fig. 14.1. The MBV (g/m2 %RH) is calculated from the change in mass per square metre per % relative humidity (Rode, 2003): MBV =
Dm AD RH
14.1
Using this approach, materials may be classified under one of five categories based on their ability to contribute to the control of humidity in a room as shown in Table 14.1. A numerical method for estimating the MBV using material physical
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort in buildings Mass change per unit surface area (g/m2)
348
8h
16 h Elapsed time
14.1 Typical graph of experimental data for the moisture buffer value (MBV). Table 14.1 Moisture buffer value classification scheme (adapted from Nordic Innovation Centre, 2005) MBV class
Minimum MBV Maximum MBV g/(m2 %RH) @ 8/16 h
Negligible Limited Moderate Good Excellent
0 0.2 0.5 1.0 2.0
0.2 0.5 1.0 2.0 –
properties was also proposed by the NORDTEST Project (Nordic Innovation Centre, 2005). It was based on a mass transport solution and assumes no boundary layer resistance. For these reasons it is distinguished by being called the ideal moisture buffer value or MBVideal and represents a theoretical maximum value where: MBV Videal = 0.00568 psat bm t p
14.2
Note that the value, bm, is the moisture (or mass) effusivity, which is analogous to the thermal effusivity described above, and is calculated by:
d p rd bm =
∂wm ∂j
psat
14.3
Enthalpy buffering is the minimization of ∆H, where H = U + PV. In the case
© Woodhead Publishing Limited, 2010
Hygrothermal materials for heat and moisture control
349
of psychrometrics, for the air in a building, internal energy, air pressure and air volume can change as a consequence of air temperature, and also partial pressure due to changes in mass concentration (moisture content of the air). This air of course interacts with the material fabric inside the building. The rates at which energy can be transported (in the form of heat) from the air to the material and back again, and the rate at which mass can be transported (in the form of water vapour) in and out of the material, can effectively create a balance effect in indoor air enthalpy. Hygrothermal materials derive their name from the fact that their hygrothermal functional properties are particularly useful for enthalpy buffering, as previously mentioned. The first most important set of functional properties relates to the control of absorption and desorption of water vapour from the air in order to maintain small changes in the humidity ratio. The second most important parameter relates to the control of absorption and desorption of energy (as heat) from the air in order to maintain small changes in dry bulb temperature. This can be visualized using a psychrometric chart (as discussed in Chapter 4) in which the influence of both humidity ratio and dry bulb temperature on air enthalpy at constant relative humidity can clearly be seen.
14.2
Characterization of hygrothermal functional properties
The following section explains how hygrothermal functional properties can be characterized along with various appropriate test methods and procedures for providing data.
14.2.1 Volume-averaged properties The main functional properties of a hygrothermal material are listed in Section 14.1, and the fundamentals behind these properties are described in detail in Chapter 2. A good hygrothermal material has, amongst other things, a high moisture buffer value (MBV) and the equivalent of a high thermal buffer value (TBV) which manifests itself as a delayed thermal response and fabric energy storage. These things are controlled by material physical properties at the microstructural level which are effectively quantified as volumeaveraged properties at the macrostructural level. The important concept behind hygrothermal behaviour, however, is that the absorption, storage and release of both heat energy and mass (moisture) are interdependent and occur simultaneously, i.e. thermal performance becomes more complicated and more important when moisture is present, and vice versa. Empirical relationships between l and constituent volume fractions, bulk density and moisture content have been obtained from experimental testing of a wide range of porous building materials by various researchers. Auto
© Woodhead Publishing Limited, 2010
350
Materials for energy efficiency and thermal comfort in buildings
coherent homogenization has been used to try simple predictions of l for two phase (air and solid) or three phase (air and mixture of solid A and solid B) porous materials by assuming that the heat transfer is analogous to that occurring across a multilayered sphere of concentric homogenized phases (Bederina et al., 2007). The cubic lattice and capillary bridge model (Ewing & Horton, 2007) proposes a mathematical description of l for dry porous materials (when the void ratio is varied), and for moist porous materials when the degree of saturation is varied. The Random Mixed Cube Model (Zhang et al., 2006) uses the three phase continuum model as a base to represent relative quantities of each phase as small discrete cubes randomly arranged within a larger finite volume cube (i.e. analogous to a Rubik’s cube). The heat transfer between adjacent cubes is modelled to provide a cumulative effect. This allows good consideration of the boundary effects but cannot accurately measure the effects of void geometry which is crucial in determining the independent functions of the matrix structure. There is much research work still to do in order to fully understand how and why the volume-averaged hygrothermal properties that we measure for a given material originate by understanding their microstructure.
14.2.2 Measurement techniques Many standard modelling techniques for thermal and hygric properties of porous materials are detailed, along with the fundamentals behind them, in Chapter 1. The important properties for a hygrothermal material are listed in Section 14.1 and the techniques for measuring them are described here. Thermal conductivity can generally be assessed using a heat flow meter (HFM), dual probe heat pulse meter (DPHP), or a guarded hot box. Thermal conductivity testing using computer-controlled heat flow meter apparatus, for example, must comply with ISO 8301 Thermal Insulation – Determination of Steady State Thermal Resistance and Related Properties (ISO 8301, 1991). For moisture-dependent thermal conductivity testing, the same HFM apparatus is used but the methodology is adapted to comply with ISO 10051 Determination of Thermal Transmissivity of a Moist Material (ISO 10051, 1996). An alternative to direct measurement is ISO 10456 Procedures for Determining Declared and Design Thermal Values (ISO 10456, 1999) which provides methodologies for the theoretical calculation of the change in thermal conductivity when influenced by, for example, variations in specimen moisture content, temperature and age. The rate of water vapour flow through a porous specimen can be determined using the wet cup/dry cup method in a temperature and humidity controlled environmental chamber (BS EN ISO 12572, 2001). By using a saturated salt solution for the ‘test’ vessel, a vapour pressure gradient can be imposed across the sample thickness thus inducing diffusive mass transfer and allowing
© Woodhead Publishing Limited, 2010
Hygrothermal materials for heat and moisture control
351
the water vapour permeability to be calculated. Sorption and desorption isotherms can be determined using small representative samples that have been oven dried to constant mass. Using an array of sealed desiccators containing different saturated salt solutions, to provide a wide range of stable relative humidity environments, the dry specimens can be progressively placed in each of the desiccators and permitted to absorb moisture vapour until equilibrium moisture content is achieved. The relationship between the moisture content of a porous material and the relative humidity of the surrounding environment is quoted using the moisture storage function (MSF). Sorptivity and rate of liquid water flow in unsaturated specimens can be measured using the partial immersion test described in Chapter 1. The hydraulic conductivity, as a function of moisture content, can be calculated based on the MSF value. Much more precise physical modelling of liquid water movement can be performed using gamma ray scanning devices and nuclear magnetic resonance (NMR) spectrometry (Hall & Hoff, 2002).
14.3
Material classes
Several engineering materials can be described as ‘hygrothermal’ exhibiting strong behaviour. In the case of building physics applications, these chiefly fall amongst the categories described in the following sub-sections although there is still much need for further research and many institutions are now actively pursuing this field.
14.3.1 Clay materials The term ‘clay’ can mean many things. It can, for example, refer to a clay soil which can be a formal geological classification, or it can refer to the behaviour of the material (clay-like) in terms of cohesion and plasticity. In terms of chemical composition, clay is a mineral belonging to the group know as phyllosilicates on account of their layered sheet-like structure. In civil engineering terms, clay is a soil material originating from a parent rock mineral and has a mean particle diameter of 2 microns or less. Clays are naturally-occurring phyllosilicates formed from various parent rock minerals, usually as the result of weathering. The many variations of naturally-occurring clay minerals are formed from layers of silicate and aluminate minerals that produce either 1:1 or 2:1 lamellar structures. They form discrete particles known as micelles, as shown by the examples given in Fig. 14.2. For further details on clay chemistry and clay mineral classification, refer to Velde (1992). Since water is a polar molecule, it is attracted to the net electrostatic charge on the surfaces of clay platelets. H + in H2O is attracted to O– in the platelet shell. The higher the specific surface area of the clay, the more water molecules will be attracted both in terms
© Woodhead Publishing Limited, 2010
352
Materials for energy efficiency and thermal comfort in buildings
Oxygen or hydroxyl
Various cations
Packed according to charge and geometry
Repeated to form a sheet Tetrahedral
Octahedral
Stacked in ionic and covalent bonding to form layers 1:1 Semi-basic unit
2:1 Semi-basic unit
Stacked in various ways
Stacked in various ways
Water ions Water + ions Water + Mg Potassium
Water layer Kaolinite
Halloysite Pyrophyllite
Smectite Vermiculite
Illite
Potassium
Chlorite
Mixed layer
14.2 Composition of typical clay mineral structures (Mitchell, 1993).
of quantity and distance of the effect. The accumulation of water (often containing hydrated metal cations) forms what is known as a double diffuse layer around the clay platelets. The thickness of this layer (or distance from the platelet surface) is determined by the surface potential of the clay, i.e. the magnitude of the net electrical charge. Some clay minerals have very low surface potentials, such as kaolinite, and hence their double diffuse layer is relatively thin in relation to the platelet size. This means that the quantity of water absorbed, when equilibrium is achieved between charged surface and water molecules, is relatively small. Other clays, such as montmorillonite, have very large specific surface areas (up to 800 m2/g) and consequently their surface potential and double diffuse layer thickness is extremely high, see Fig. 14.3. These minerals can absorb very large quantities of water but obviously they expand considerably in volume whereas less reactive clays do not. Clays generally have a small range of achievable l, and a slightly bigger range for dry density/porosity. This means that thermal resistance, R, cannot change much for a given thickness (in the dry state) between materials. However, when water is introduced, even in small amounts it, can vary considerably depending upon pore structures and their properties. This means that thermal storage and also thermal diffusivity can be altered, and hence thermal buffering can be manipulated. Crucially, clay minerals are very hygroscopic due to their chemical composition as described above. Unfired clay bricks are often referred to as ‘green bricks’ as they use less energy during the production process and are simply air-dried rather than
© Woodhead Publishing Limited, 2010
Hygrothermal materials for heat and moisture control
353
40 nm Adsorbed water 100 nm
20 nm
Kaolinite crystal
20 nm
Montmorillonite crystal (1 nm thick)
40 nm
14.3 Relative sizes of adsorbed water layers surrounding a montmorillonite clay particle (left) and a kaolinite particle (right) (adapted from Holtz & Kovacs, 1981).
being fired in a kiln. They can be formed by hand or mechanically extruded and are dried until the equilibrium moisture content is reduced to around 2%. Many shapes and sizes can be created through the use of a variety of different moulds. They are designed to be used for non-structural, internal applications because they degrade when in long-term contact with water, i.e. exposure to weather. The bricks create little waste during production, require less energy to produce them, and can be either recycled or cleanly disposed of when no longer needed (Morton, 2006). Bricklaying can be done following conventional trade practices, although the bricks must either be left exposed or coated with a highly breathable paint, surface treatment or plaster. Unfired clay bricks are a relatively new idea in Great Britain; however, in other parts of Europe, particularly Germany, it has developed a good reputation and been perceived as a viable building solution. A number of UK suppliers have started to produce earth bricks to meet the ever-increasing interest in these methods. Ibstock, for example, have released a line of earth bricks known as ‘Ecoterre bricks’ and even equip buyers with a list of retailers who supply materials such as mortars and paints to be used alongside their products. The Errol Brick Company in Scotland also produces a range of green clay bricks and, along with Arc Architects, Fife, have successfully been used in a small-scale trial building to regulate relative humidity over the period of a year. The test house was designed to passively regulate internal relative humidity between 40% and 60%, and tests confirmed that in the bathroom humidity regulation was the same after a shower whether or not mechanical ventilation was in use (Morton, 2005). Water vapour sorption of 1.5–2.3% wt at 80% RH and a vapour permeability of between 8 and 16 ¥ 10–12 kg/(Pa s m) is reported by Hansen & Hansen (2002). In addition, they found that an active depth (i.e. the depth from the surface involved in sorption/desorption) of between 4.1 and 5.1 mm was available on green clay bricks for humidity buffering.
© Woodhead Publishing Limited, 2010
354
Materials for energy efficiency and thermal comfort in buildings
Clays can be used in combination with fibre reinforcement (to prevent expansion/contraction cracking) as interior plaster for buildings and occupied spaces. A good example of this is the range of clay plasters produced by CLAYTEC, Germany, although other manufacturers now make similar products. One of the main advantages of clay plasters are that they have the ability to absorb and diffuse water vapour for buffering of interior relative humidity fluctuations. The plasters are also perceived to be more environmentally friendly because they are not calcined (heated at high temperatures to dissociate CO2) and do not contain any energy-intensive binders such as Portland cement or lime.
14.3.2 Stabilized earth materials It is claimed that rammed earth (RE) or stabilized rammed earth (SRE) walls can be used as a building-integrated source of ‘passive air conditioning’, which is a combination of indoor moisture buffering and air temperature buffering (Allinson & Hall, 2007). They are ‘building integrated’ because the walls themselves act as a load-bearing external envelope. SRE structures are increasingly accepted in other developed countries such as the USA, Canada and Australia where in some regions they account for up to 20% of all new build (Easton, 1996); see the example in Fig. 14.4. In the UK, the Rammed Earth Design & Construction Guidelines, published by BRE Bookshop (Walker et al., 2005) were developed as part of a DTi Partners in Innovation Project under the title ‘Developing Rammed Earth for UK Housing’. These materials have a strong ability to passively cool a building by naturally absorbing heat gains, and re-radiating the stored heat energy
Temperature buffering
Moisture buffering
14.4 Interior of an SRE house with exposed surfaces to allow hygrothermal buffering (© 2000–2009 Trevor Mein).
© Woodhead Publishing Limited, 2010
Hygrothermal materials for heat and moisture control
355
when the ambient temperature falls, i.e. the thermal flywheel effect. The porous nature of the material coupled with the presence of hygroscopic clay minerals also enables the walls to passively control the humidity of a building’s internal environment, i.e. a humidity-based version of the thermal wheel. Current research by the author is investigating how to control SRE material properties such that the passive cooling and dehumidification could be specified, thus enabling these to be tailored to the design of a building. The potential future outcome could be buildings that regulate themselves so that only a relatively small intervention from mechanical building services is required. An electronically monitored SRE house in Sydney, for example, which was left unoccupied and with no curtains for over a year had an average annual indoor temperature range of 18–27 °C, when the outdoor temperature range was 7–42 °C (Mortensen, 2000). A two-storey SRE office in New South Wales also displayed good indoor environmental performance over a hot summer due to passive cooling and dehumidification (Taylor & Luther, 2004).
14.3.3 Timber Timber is a naturally-occurring cellular fibre composite that chiefly comprises cellulose (fibre) and lignin (matrix). Timber is a light, strong material, used in building structures for millennia because it is renewable, simple to manufacture, easy to use, stable and safe. It has an inherently low thermal conductivity although both its structural behaviour and durability may be adversely affected by moisture. The physical properties of timber vary greatly between species. Hardwoods are normally from broad-leaved deciduous trees (e.g. oak, ash, beech, elm, mahogany) that are slow growing and therefore have a dense, close-grained cellular structure but that can be prone to fungal attack. Softwoods are from fast-growing coniferous trees (e.g. normally evergreens such as spruce, pine, douglas fir) that have lower density, a much more open grained structure, and are mostly softer than their hardwood counterparts. The coefficient of variability for timber materials can be greatly reduced when knots and other defects are removed and/or lamination techniques are used. In hardwoods purpose-grown large vessels occur whose function is to transport fluids through the plant, whereas in softwoods this function is achieved within the main cellular structure. For further details on timber microstructure, refer to Dinwoodie (2000). Within the cellular structure of timber there are individual openings known as a ‘torus’ which can open and close to allow in response to moisture movement. The electron microscope image in Fig. 14.5 clearly shows the vertically aligned cellular tissue of a piece of European spruce where at least one torus is visible inside each broken vessel. Note that the specimen was prepared by tensile failure which
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort in buildings European spruce – tensile fracture surface
800x
356
Back scattered electron detector imaging using Philips XL-40 ASEM
5000x
400x
14.5 Electron microscope images of the cellular microstructure of European spruce timber.
clearly exposes the fibre composite nature of the cellular tissue. One can appreciate that the equilibrium moisture content, at a known relative humidity (which of course can be used to plot a sorption isotherm; see Chapter 1), is normally very high for timber in comparison with other building materials such as brick, concrete and plaster. Gaur and Bansal (2002) used a simplistic model of a spruce-lined room to demonstrate that it was necessary to consider moisture transfer if room air temperature was to be modelled. They found that neglecting the hygroscopic fabric resulted in temperature errors of 2–3 °C for climatic conditions in Delhi, India. Osanyintola and Simonson (2006) suggested that spruce plywood can reduce both the heating and cooling demand in a building. Heating demand could be reduced while the building was occupied (as moisture accumulated in the fabric releases heat) but increased while the building was unoccupied as energy was needed to dry out the walls. Good system control produced an overall saving. The cooling load could be reduced by a greater amount due to lowering of the enthalpy of the air through the reduced humidity. Further savings were expected from improved indoor air quality allowing for increasing indoor temperatures during the summer, reducing them in winter and lowering ventilation rates.
14.3.4 Natural fibre materials and composites Many natural fibres have the ability to absorb, store and release water vapour from the air and therefore make good candidates for hygrothermal materials in buildings. These include straw, hemp, sisal, flax, jute and many others. The
© Woodhead Publishing Limited, 2010
Hygrothermal materials for heat and moisture control
357
issue of bio-degradable materials such as these is protecting the fibre from decay when moisture is present by use of stabilizing materials. ‘Hemcrete®’ is a lime–hemp composite material made using hemp shiv and a hydrated lime binder (see the cross section shown in Fig. 14.6). They have a high thermal insulation and high water vapour permeability that can reduce the development of condensation and trapped moisture within the building. As with all good humidity buffering materials, it can also improve the indoor air quality by controlling the relative humidity as well and reducing the potential for mould growth. A hygrothermal analysis of a lime–hemp composite was conducted by the Fraunhofer Institute for Building Physics in Holzkirchen, Germany using WUFI software and three theoretical case studies. Evrard (2006) reports an experimentally determined MBV of 1.39 g/m2∙%RH for lime–hemp materials and a dry thermal conductivity of 0.115 W/m K. Some manufacturers are now marketing a commercial lime–hemp product as Hemcrete®, an example application of which is shown in Fig. 14.7.
14.6 Cross section through a lime–hemp composite wall (© 2000– 2009 Lime Technology Limited).
© Woodhead Publishing Limited, 2010
358
Materials for energy efficiency and thermal comfort in buildings
14.7 The Adnams Brewery facility in Suffolk, England built with Hemcrete® walls for hygrothermal buffering (© 2000–2009 Lime Technology Limited).
14.3.5 Smart materials The work conducted during the NORDTEST Project involved determining the relative humidity buffering capacity of conventional building materials such as concrete, wood, gypsum plaster and brick. Following on from this, some researchers have attempted to develop ‘smart materials’ with very high buffering capacity that can be used to better regulate the indoor environmental conditions without the use of air conditioning systems. Candidate absorbent materials included silica desiccants, zeolites and molecular sieves. Others include sodium polyacrylate, with a reported MBV of 8.97 g/m2 %RH, and cellulose with an MBV of 3.07 g/m2 %RH (Cerolini et al., 2009). These materials were evaluated for an exposure to cyclic fluctuation between 75% RH and 33% RH over test periods of 8 h and 16 h. Some hysteresis was involved, as expected from looking at a sorption isotherm; sodium polyacrylate suffers from high hysteresis whereas the cellulose-based has a lower hysteresis.
14.4
Applications in buildings and occupied spaces
Many researchers, architects and engineers are making increasing use of hygrothermal materials for the passive regulation of indoor relative humidity, to reduce/eliminate problems associated with condensation and/or degradation of materials and furniture, and to increase the quality of indoor air. This applies not only to domestic buildings but also, for example, to office buildings with relatively high daytime air moisture loads, where the ‘hygrothermal’
© Woodhead Publishing Limited, 2010
Hygrothermal materials for heat and moisture control
359
material can be both cooled and dried at night time/off-peak times through the use of natural ventilation and night cooling strategies.
14.4.1 Thermal buffering, comfort and energy efficiency in buildings Thermal buffering is the combined effect of materials absorbing, storing and releasing heat energy to their surroundings in response to changes in environmental conditions. The use of exposed thermal mass in buildings to reduce peak summertime temperatures and cooling loads in buildings is well established. Peak indoor temperatures are reduced when the heat gains (especially solar and internal heat gains) are absorbed by the building fabric which is in turn cooled overnight in readiness for the next day. During the heating season, the same thermal mass tends to absorb heat intended for the interior space and thereby increases energy demand. Good, passive solar design (BRESCU, 1998) and thermally efficient buildings with continuous low level heating (TCC, 2006) can be used to overcome this problem. Ultimately thermal mass can reduce overall energy demand, and improve thermal comfort, in properly designed buildings. In the UK, climate change is predicted to increase the summertime cooling load and reduce winter heating, reinforcing the case for thermally heavyweight buildings (Arup R+D, 2005). What appears to be less understood is that effective control of the air enthalpy, by controlling air moisture content, can significantly reduce the peak cooling loads and hence allow the thermal mass to become more effective. In addition, the material properties, such as thermal conductivity, density and heat capacity, are moisture content-dependent and can vary significantly and in a non-uniform manner. Hence, more accurate consideration and predictive modelling of thermal mass behaviour, and indeed the future design of thermal mass material technologies, will require a more sophisticated understanding using the hygrothermal approach.
14.4.2 Humidity buffering and perceived comfort in buildings Similarly, the use of exposed hygroscopic building materials has the potential to control the relative humidity of the interior of a building and its structure. Peak indoor humidity is reduced as internal and external moisture gains are absorbed by the building fabric to be returned during periods of low humidity. This passive humidity control has the potential to reduce the energy needed for mechanical systems through improving the perceived indoor air quality and thermal comfort for building occupants as well as directly reducing the sensible and latent heating and cooling loads. Toftum et al. (1998a) found that the humidity of the air that we inhale has a significant effect on the
© Woodhead Publishing Limited, 2010
360
Materials for energy efficiency and thermal comfort in buildings
perceived acceptability of that air. Discomfort was thought to be due to reduced evaporative and convective cooling of the mucous membranes in the respiratory tract when breathing high humidity air (Toftum et al., 1998b). By reducing the humidity, higher indoor temperatures will be acceptable, reducing the cooling load of a building. Fang et al. (1998a) also found that the temperature and humidity of inhaled air had a significant effect on the perception of indoor air quality though little influence on the odour intensity of pollutants from building materials. Acceptability was found to be linearly correlated with the enthalpy of the air for a constant pollution level. Similar, though less distinct, results were found for whole body exposure (Fang et al., 1998b). Therefore, by reducing air temperature and humidity, acceptable air quality may be achieved at reduced ventilation rates. Reducing ventilation would lead to a lowering of the heating demand in winter and air conditioning in summer.
14.4.3 Dampness and mould control in buildings In an experimental study of Swedish apartment buildings, Hameury and Lundström (2004) found that exposed massive wood contributed to the thermal mass effect and buffered indoor temperature variations. Modelling of the heat and mass transfer processes suggested that the contribution of the wood to moisture buffering was significant, especially at low air ventilation rates (Hameury, 2005). Further potential benefits of hygroscopic building materials include a reduction in dust mite populations and mould growth (beneficial for asthma and allergies) (Cunningham, 1996) and a reduction in structural degradation caused by moisture ingress (Lucas et al., 2002). This form of passive relative humidity control may be particularly appropriate to museums, art galleries and libraries, and also to heritage structures (e.g. historic buildings that allow visitor access) where the displayed items are sensitive to moisture. The use of mechanical systems (e.g. air conditioning) in these environments can often be inappropriate, especially in important historic buildings, and the need for a reliable, non-powered humidity control system is vital for the preservation of museum artefacts or sensitive media such as cloth and paper.
14.5
Future trends
There is a clear need to carefully match hygrothermal materials and their behaviour patterns with mechanical systems engineering design. Firstly, this will maximize the ability of hygrothermal materials to passively regulate indoor environmental conditions and reduce the energy use from mechanical systems, and secondly it will avoid any conflict between the operation of the mechanical system and the material response which could (in the worst case) result in over-sizing the dehumidification and cooling loads. Barbosa
© Woodhead Publishing Limited, 2010
Hygrothermal materials for heat and moisture control
361
and Mendes (2008) demonstrate, using a whole building hygrothermal model, that it is important to consider the hygrothermal behaviour of the building material when sizing the heating, ventilating and air conditioning (HVAC) system. Their work, based on a case study in Brazil, shows that disregarding moisture may oversize the system by 13% and underestimate the energy required for cooling by 4%. Künzel et al. (2003) use validated computer modelling to show that the reduction in cooling load may not be as simple as many first think because the moisture absorbed during air conditioning shut off periods is re-emitted when the system is turned back on – which increases the latent heat capacity of the air.
14.6
Sources of further information and advice
In addition to research being conducted in this field by the author, numerous very well-established research teams and organizations are involved directly or indirectly with hygrothermal materials. A selection of them is presented in Table 14.2, although this list is by no means exhaustive. A number of computer models have been developed for use with hygrothermal material properties and in tandem with building/occupied space assessment and analysis. A selection of the most widely used and validated models is given in Table 14.3.
Table 14.2 A list of institutions and research teams involved with hygrothermal materials research Institute
Location
Fraunhofer Institute for Building Physics Oak Ridge National Laboratory (DOE) National Research Council Canada – Institute for Research in Construction (NRCC-IRC) University of Saskatchewan VTT Technical Research Centre Technical University of Denmark Royal Institute of Technology Helsinki University of Technology Tampere University of Technology Tallinn Technical University Lund University Dresden University University of Helsinki Pontifical Catholic University of Parana University of Nottingham
Germany USA
© Woodhead Publishing Limited, 2010
Canada Canada Finland Denmark Sweden Finland Finland Estonia Sweden Germany Finland Brazil UK
362
Materials for energy efficiency and thermal comfort in buildings
Table 14.3 A selection of the most widely used computer models for use with hygrothermal material properties. Model
Institution
Country
1D-HAM DELPHIN 4, DIM 3.1 EMPTIED GLASTA hygIRC Hygran24 LATENTITE MATCH MOIST 3 MOISTURE-EXPERT TCCC2D TRATMO UMIDUS WALLDRY WUFI Pro/Plus WUFI ORNL/IBP
Chalmers University of Technology Technical University of Dresden Canada Mortgage and Housing Corporation Physibel Software Institute for Research in Construction Catholic University of Leuven National Research Centre Technical University of Denmark National Institute of Standards and Technology Oak Ridge National Laboratory VTT Technical Research Centre VTT Technical Research Centre Pontifical Catholic University of Parana Canada Mortgage and Housing Corporation Fraunhofer Institute for Building Physics Oak Ridge National Laboratory
Sweden Germany Canada Belgium Canada Belgium Canada Denmark USA USA Finland Finland Brazil Canada Germany USA
14.7
Acknowledgements
The author wishes to acknowledge the assistance and helpful discussion of Dr David Allinson during the preparation of this chapter.
14.8
References
Allinson D and Hall M, 2007, ‘Investigating the optimisation of stabilised rammed earth materials for passive air conditioning in buildings’, in Proceedings for the International Symposium of Earthen Structures, Bangalore 22–24 August. Arup R+D, 2005, ‘UK housing and climate change: heavyweight vs. lightweight construction’, A technical report for Ove Arup and Partners Ltd, London Barbosa RM and Mendes N, 2008, ‘Combined simulation of central HVAC systems with a whole-building hygrothermal model’, Energy and Buildings, 40(3), 276–288. Bederina M, Marmoret L, Mezreb K, Khenfer MM, Bali A and Quéneudec M, 2007, ‘Effect of the addition of wood shavings on thermal conductivity of sand concretes: experimental study and modelling’, Construction and Building Materials, 21(3) 662–668. BRESCU, 1998, Planning for Passive Solar Design, BRECSU, BRE, Watford. BS EN ISO 12572, 2001, Hygrothermal performance of building materials and products – Determination of water vapour transmission properties, British Standards Institute, London. Cerolini S, D’Orazio M, Di Perna C and Stazi A, 2009, ‘Moisture buffering capacity of highly absorbing materials’, Energy and Buildings, 41(2), 164–168. Cunningham MJ, 1996, ‘Controlling dust mites psychrometrically – a review for building scientists and engineers’, Indoor Air, 6(4), 249–258. Dinwoodie JM, 2000, Timber: its nature and behaviour, 2nd edn, Taylor and Francis, London.
© Woodhead Publishing Limited, 2010
Hygrothermal materials for heat and moisture control
363
Easton D, 1996, The Rammed Earth House, The Chelsea Green Publishing Company, Vermont. Evrard A, 2006, ‘Sorption behaviour of lime–hemp concrete and its relation to indoor comfort and energy demand’, PLEA2006 – 23rd Conference on Passive and Low Energy Architecture, Geneva, Switzerland, 6–8 September. Ewing RP and Horton R, 2007, ‘Thermal conductivity of a cubic lattice of spheres with capillary bridges’, Journal of Physics D: Applied Physics, 40(16), 4959–4965. Fang LG, Clausen G and Fanger PO, 1998a, ‘Impact of temperature and humidity on the perception of indoor air quality’, Indoor Air, 8(2), 80–90. Fang LG, Clausen G and Fanger PO, 1998b, ‘Impact of temperature and humidity on perception of indoor air quality during immediate and longer whole-body exposures’, Indoor Air, 8(4), 276–284. Gaur RC and Bansal NK, 2002, ‘Effect of moisture transfer across building components on room temperature’, Building and Environment, 37, 11–17. Hall C and Hoff WD, 2002, Water Transport in Brick, Stone and Concrete, Taylor & Francis, London. Hameury S, 2005, ‘Moisture buffering capacity of heavy timber structures directly exposed to an indoor climate: a numerical study’, Building and Environment, 40(10), 1400–1412. Hameury S and Lundström T, 2004, ‘Contribution of indoor exposed massive wood to a good indoor climate: in situ measurement campaign’, Energy and Buildings, 36(3), 281–292. Hansen EJdP and Hansen KK, 2002, ‘Unfired clay bricks – moisture properties and compressive strength’, in Building Physics 2002 – 6th Nordic Symposium, 17–19 June, Trondheim, Norway. Holtz RD and Kovacs WD, 1981, An Introduction to Geotechnical Engineering, PrenticeHall, Englewood Cliffs, NJ. ISO 8301, 1991, Thermal insulation – Determination of steady-state thermal resistance and related properties – Heat flow meter apparatus, International Organization for Standardization, Geneva, Switzerland. ISO 10051, 1996, Thermal Insulation – Moisture effects on heat transfer – Determination of thermal transmissivity of a moist material, International Organization for Standardization, Geneva, Switzerland. ISO 10456,1999, Building materials and products: Procedures for determining declared and design thermal values, International Organization for Standardization, Geneva, Switzerland. Künzel HM, Zirkelbach D and Sedlbauer K, 2003, ‘Predicting indoor temperature and humidity conditions including hygrothermal interactions with the building envelope’, in Proceedings of 1st International Conference on Sustainable Energy and Green Architecture, BSRC, Bangkok. Lucas F, Adelard L, Garde F and Boyer H, 2002, ‘Study of moisture in buildings for hot humid climates’, Energy and Buildings, 34, 345–355. Mitchell JK, 1993, Fundamentals of Soil Behaviour, John Wiley & Sons, London. Mortensen N, 2000, ‘The naturally air conditioned house’, Earth Building Research Forum, University of Technology Sydney, Australia, available via: http://www.dab. uts.edu.au/ebrf/ Morton T, 2005, ‘Unfired earth brick building’, Building for the Future, 24–27. Morton T, 2006, ‘Feat of clay’, Materials World, 14(1), 23–24. Nordic Innovation Centre (NIC), 2005, ‘Moisture buffering of building materials’, Technical report BYG-DTU R-126, Technical University of Denmark. © Woodhead Publishing Limited, 2010
364
Materials for energy efficiency and thermal comfort in buildings
Osanyintola OF and Simonson CJ, 2006, ‘Moisture buffering capacity of hygroscopic building materials: experimental facilities and energy impact’, Energy and Buildings, 38(10), 1270–1282. Rode C, 2003, Workshop on Moisture Buffer Capacity – Summary Report R-067, Department of Civil Engineering, Technical University of Denmark. Sedlbauer K, 2002, ‘Prediction of mould growth by hygrothermal calculation’, Journal of Thermal Envelope and Building Science, 25, 321–335. Taylor P and Luther MB, 2004, ‘Evaluating rammed earth walls: a case study’, Solar Energy, 76, 79–84. TCC, 2006, Thermal Mass for Housing, The Concrete Centre, Surrey. Toftum J, Jorgensen AS and Fanger PO, 1998a, ‘Upper limits of air humidity for preventing warm respiratory discomfort’, Energy and Buildings, 28(1), 15–23. Toftum J, Jorgensen AS and Fanger PO, 1998b, ‘Upper limits for indoor air humidity to avoid uncomfortably humid skin’, Energy and Buildings, 28(1), 1–13. Velde B, 1992, Introduction to Clay Minerals, Springer, Berlin. Walker P, Keable R, Marton J and Maniatidis V, 2005, Rammed Earth Design and Construction Guidelines, BRE Bookshop, Watford. Zhang H, Ge X and Ye H, 2006, ‘Randomly mixed model for predicting the effective thermal conductivity of moist porous media’, Journal of Physics D: Applied Physics, 39, 220–226.
14.9 A b m c p H m P psat R RH t p U V w m a b dp r rd l ϕ
Appendix: Nomenclature area moisture effusivity constant pressure specific heat capacity enthalpy mass fluid pressure saturation vapour pressure thermal resistance relative humidity period internal energy volume moisture content thermal diffusivity thermal effusivity water vapour permeability density dry density dry state thermal conductivity relative humidity (decimal)
m2 kg/(m2 Pa s1/2) J/kg K J kg Pa Pa m2 K/W % s J m3 kg/kg m2/s W s1/2/m2 K kg/m s Pa kg/m3 kg/m3 W/m K –
© Woodhead Publishing Limited, 2010
15
Desiccant materials for moisture control in buildings
B. Warwicker, UK
Abstract: Desiccant is a material for modifying humidity; the chapter explains the absorption and adsorption desiccant processes. The chapter reviews the commercial, solid and liquid desiccant processes, together with selected practical applications. Health, comfort and air quality, as well as energy coefficient of performance (COP), energy efficiency ratio (EER) and seasonal energy efficiency ratio (SEER) are discussed. Finally the chapter looks to the future and reviews the more natural approach to modifying building humidity with normal building materials and reviews practical applications. Key words: desiccant, sorbent, absorbent, adsorbent, health, comfort, air quality, silica, alluminium, lithium chloride, cellular concrete, gypsum lime, wood, indoor climate, energy efficiency raho (EER), seasonal energy efficiency raho (SEER).
15.1
Introduction
Sorption is the binding of one substance to another. Sorbents are materials that have the ability to attract and hold other gases or liquids. Desiccants are a subset of sorbents. All desiccants behave in a similar way; they attract moisture until they reach equilibrium with their surroundings. Moisture may be removed from a desiccant by heating. Once the desiccant is dry it must be cooled before it can attract moisture once again. Sorption generates sensible heat equal to the latent heat of the water taken up by a desiccant, isosteric enthalpy. In addition, the heat of sorption varies between 5 and 25% of the latent heat of water vapour which is dependent on the permeability/hygroscopicity of the desiccant. These are two distinct functions. The process of attracting and holding moisture is described as either absorption or adsorption, depending on whether the desiccant undergoes change as it takes in moisture. Absorption changes the desiccant. An example of an absorbent is table salt which changes from a solid to a liquid as it absorbs moisture. Adsorption does not change the desiccant, except by the addition of the weight of water adsorbed. An example of adsorption is a sponge. Virtually all materials are desiccants; that is they attract and hold water 365 © Woodhead Publishing Limited, 2010
366
Materials for energy efficiency and thermal comfort in buildings
vapour. Wood, natural fibres, clays, and many synthetic materials attract and release moisture as commercial desiccants do, but they lack holding capacity. Commercial desiccants continue to attract moisture even when the surrounding air is quite dry, a characteristic that the other materials do not share. Desiccants, whether liquid or solid, hold moisture through absorption or adsorption. Most absorbents are liquids and most adsorbents are solids.
15.2
Desiccant cycle
All desiccants function by moisture transfer caused by a difference between water vapour pressures at their surface and that of the surrounding air (Fig. 15.1). Liquid absorption is a dehumidification process. The vapour pressure of liquid absorption is directly proportional to temperature and inversely proportional to its concentration. The vapour pressure of a given concentration of absorbent solution approximates to the vapour pressure value of a fixed relative humidity line on a psychrometric chart. Higher concentrations provide a lower equilibrium and relative humidity, which allow the absorbent to dry air to lower levels (Fig. 15.2). Adsorbents are solid materials with a tremendous internal surface area per unit of mass that attract moisture because of the electrical field at the material’s surface. This field is not uniform in either force or charge. When the complete surface is covered, the adsorbent can still hold more moisture because vapour continues to condense into the first layer and fill the capillaries throughout the material. As with absorbents, the ability of an adsorbent to attract moisture depends on the vapour pressure between its surface and the air. 120 °C
Reg
ene
Cooling
Desiccant surface Vp
3
rati
on 2
So
on rpti
1
Desiccant moisture content
15.1 Desiccant cycle.
© Woodhead Publishing Limited, 2010
10 °C
Desiccant materials for moisture control in buildings Water
20
60
Glycol solutions 55
Lici solutions 50%
50 10
te Wa
r
15% 25% 45%
10
20
30 40 Solution temp (°C)
40
90%
30
98%
50
Dewpoint °C
Surface vapour pressure (kPa)
367
60
15.2 Comparison of liquid desiccants and water.
Adsorption behaviour depends on total surface area, the total volume of the capillaries and the range of capillary diameters. A large surface area will give the adsorbent a larger capacity at low relative humidity. Large capillaries provide a high capacity at high relative humidity. A narrow range of capillary diameters makes an adsorbent more selective in the vapour molecules it can hold. Water molecules migrate slowly through solid materials by diffusion, propelled by the difference between water vapour pressures on each side of the material. The molecules move slightly faster when the material is more permeable/hygroscopic and the greater the water vapour pressure difference. The unit that defines water vapour movement through a material is called ‘perm’. One perm is the number of nanograms per second that pass through one square metre with a pressure difference of one Pascal.
15.3
Desiccant applications
Desiccants can dry liquids or gases, including moisture from air and are used in many air conditioning applications. It is the air conditioning application that is of interest. Desiccant systems have already been implemented in many buildings. The technology promises to advance building technology in the 21st century and help the individual achieve ‘the right to healthy indoor air’ with minimal environmental impact.
15.4
Health and comfort
If humidity in the air has nowhere to go and levels rise, this can create an ideal environment for mites and mould, which start to thrive above 50% © Woodhead Publishing Limited, 2010
368
Materials for energy efficiency and thermal comfort in buildings
relative humidity (rainy day is 100% RH and middle of the desert is 0% RH). This is represented by a maximum absolute moisture content of 8 g/ kg at 21 °C in the space; below 40% RH the mites die. Humans are most comfortable between 40 and 60% RH, i.e. 6–9 g/kg at 21 °C. The influence of moisture on people is one of the least understood of all the comfort factors. ∑ Comfort is affected by skin wetness; skin also requires water content to remain supple. ∑ Dry throats and noses lower the resistance to infection. ∑ Dry itchy eyes in very dry conditions lead to a breakdown in tear film. ∑ Clothing is influenced by moisture, both insulation and permeability. The electrical properties are also affected and can create electrostatic charges as well as in surrounding materials. ∑ Health and allergies are affected; very dry conditions lower the resistance to infection and damp conditions enable moulds and mites to flourish. ∑ Odour, irritant and dust effects are perceived worse at low humidities; the release of formaldehyde gas is also affected by humidity. Figure 15.3 shows the modes of heat loss at various temperatures of a clothed sedentary person. It is interesting to note that most comfort surveys treat moisture as an independent factor unrelated to comfort. Studies show that a 30% increase in relative humidity is equal to a 1 °C rise in temperature. Thus, if humidity levels are reduced then ‘comfort’ temperatures could be allowed to rise (Fig. 15.4).
Heat loss (W)
150
100 Evaporation
Co 50
nv
ec
tio
n
Radiation 10
20 30 Temperature (°C)
40
15.3 Heat loss by clothed sedentary person.
© Woodhead Publishing Limited, 2010
Desiccant materials for moisture control in buildings
369
28 27
Comfort (°C)
26 25
Women
24 23
Men
22 21 0
20
40
% RH
60
80
100
15.4 Influence of humidity on comfort.
Moisture is an important factor in our comfort and health. Tests and studies confirm sensitivity to both dry and humid conditions. The time taken for these sensitivities to impact vary from 15 minutes to an hour for eye dryness to a few hours for body dryness and weeks for an overall feeling of unpleasant dryness. In humid conditions the sensitivities impact more quickly, skin becomes damp, the atmosphere becomes sultry and we overheat. Research evidence indicates that at low temperatures of 20 °C and high relative humidities of 65% people are the most comfortable; however, the modern trend is to provide higher temperatures, especially in passive buildings, which makes it difficult to achieve healthy and comfortable moisture conditions (Fig. 15.5).
15.5
Air quality
Indoor air pollution poses many challenges to health. Studies have shown that people spend more than 90% of their time indoors. Volatile organic compounds (VOCs) are a class of pollutants that pose a risk to human health since they can be toxic at very low concentrations (ppb). The adverse health effects caused by these compounds can range from minor complaints, such as irritation of the nasal and ocular mucosa, to chronic complications such as the exacerbation of asthma. Removal of VOCs by conventional means such as photo catalytic oxidation, ionization, condensation and ozone oxidation have proved insufficient due to the nature of VOCs and their very low concentrations in the air. The recent focus has been on sorption filtration using desiccant materials for the simultaneous removal of both water vapour and other pollutants from
© Woodhead Publishing Limited, 2010
370
Materials for energy efficiency and thermal comfort in buildings
Comfort (°C)
30
Electric shocks at lower RH
25
20
Damp clothing
Dry eyes
Clammy forehead
Comfort
Chapped skin at lower RH
Dry throat at lower RH
Sultry at higher RH
15 0
20
40 60 Comfort (% RH)
80
100
15.5 Influence of moisture on people.
air (co-sorption) as it is an energy efficient process eliminating the need for cooling air to dew point temperatures to remove water vapour. Experimental and predictive methods have been used to determine the suitability of adsorbents for pollutant removal. The results indicate an improved indoor environmental quality (IEQ) where desiccants were used to clean the air. Adsorption involves competition for binding sites on the surface of the adsorbent by the adsorbing molecules. Research has established that although competition exists between water and the pollutant molecules on desiccants, their capacity for adsorption remains relatively unaffected.
15.6
Natural and commercial desiccants: typical materials
It is the air surrounding the material that controls its water content. The exact water content of a material depends on the temperature and moisture content of the surrounding air. The material permeability/hygroscopicity will determine its moisture content relative to that of the surrounding air. Each material has its own sorption isotherm which is a graph of equilibrium moisture content (EMC) versus relative humidity at a constant temperature (Fig. 15.6). Many materials produce similar results, e.g. cotton, lime, linen, silica gel, silk, wood, wool and concrete. The amount of water in the air is a negligible portion of the water content in the material. Thus when the temperature is increased, the relative humidity of the air is only marginally increased. But the absolute moisture content of the air increases as a direct result of the change of temperature, whilst the moisture content of the material stays relatively constant. Thus
© Woodhead Publishing Limited, 2010
Desiccant materials for moisture control in buildings
371
30
EMC (%)
20
0 °C
10
30 °C
0 0
20
40
% RH
60
80
100
15.6 Typical variation of material moisture content.
the equilibrium curve moves horizontally across the graph. Removing the material from the air whilst reducing the temperature of the air will create an increase in relative humidity. If the material had remained whilst the air temperature was reduced, then the relative humidity would only have fallen slightly. In summary, water absorbent materials tend to keep relative humidity constant. A change in material temperature will cause a change in the surrounding air. Moisture mass is the equivalent of thermal mass in ‘passive design’. Natural moisture open, hygroscopic, materials such as clay, hemp, lime plaster, wood and mineral paints can provide ceilings, floors and walls in buildings that are reactive to moisture. Mechanical ventilation is a crude tool for removing moisture and is less efficient than hygroscopic materials. The use of hygroscopic materials in buildings must be an essential part of ‘passive design’. Commercial desiccants, liquids or solids hold moisture through absorption or adsorption. Most absorbents are liquids and most adsorbents are solids. Liquid absorption dehumidification is best illustrated by comparison with an air washer. When air passes through an air washer, its dew point approaches that of the water temperature. In a similar manner, in a liquid absorption dehumidifier, as the vapour pressure of the solution is lower than the vapour pressure of the moisture in the air (at the same temperature), it is dehumidified. The concentration of an absorbent solution approximates to a fixed humidity line on a psychrometric chart. In practice, the behaviour of a liquid desiccant is controlled by its temperature, concentration or both. Commercially available liquid desiccants have an especially high water holding capacity. For example each molecule of lithium chloride (LiCl) can hold two water molecules, in a dry state. Above
© Woodhead Publishing Limited, 2010
372
Materials for energy efficiency and thermal comfort in buildings
two it becomes a liquid and continues to absorb water; in equilibrium with air at 90% RH 26 molecules of water is held. This is equivalent to 1000% of water absorption by weight. Absorbents are solid materials with a tremendous internal surface area per unit of mass. They resemble a sponge; a single gram can have more than 5000 m2 of surface area. Adsorbents attract moisture due to the electrical field at the surface of the desiccant. The field is not uniform so specific sites attract water molecules that have a net opposite charge. As with liquid absorbents the ability of an adsorbent to attract moisture depends on the vapour pressure difference between its surface and the air. The capacity of solid adsorbents is generally less than liquid absorbents. A typical molecular sieve can hold 17% of its dry weight in water with air at 20 °C and 20% RH compared with LiCl which can hold 130% of its mass at the same temperature and relative humidity. Solid absorbents have many other favourable traits, e.g. molecular sieves continue to absorb moisture even when hot. Several solid absorbents can be manufactured to precise tolerances enabling pore diameters to be closely controlled to absorb molecules of specific diameter. This selective characteristic is useful as several desiccants with differing pore sizes can be combined to remove first water then other specific contaminants, such as VOCs. Silica gels and most other absorbents can be manufactured for a specific application, balancing capacity against strength, weight and other characteristics. Typical solid absorbents comprise activated alumina, carbons, silica gels, synthetic polymers, synthetic zeolites (molecular sieves) and zeolites. Activated aluminas are oxides and hydrides of aluminium manufactured from a thermal process. Carbons are most frequently used for the absorption of gases as they have a greater affinity for the molecules typical of organic solvents. They also have a high capacity to absorb water vapour at high humidities. Silica gels are formed by condensing soluble silicates. They are low cost and easy to customize. Synthetic polymers have a capacity that exceeds many other solid desiccants due to long molecules, such as polystyrenesulfonic acid sodium salt (PSSASS) that are twisted together like strands of string. Each of the many sodium ions in the long PSSASS molecules has the potential to bind several water molecules. Synthetic zeolites or molecular sieves are crystalline aluminosilicates manufactured in a thermal process. Control of the manufacturing process permits close control of the structure and surface characteristics. This is a more costly product than naturally occurring zeolites. Zeolites and aluminosilicates occur in nature and are mined rather than processed. Zeolites have a very open crystalline lattice that allows water vapour molecules to be held in the lattice openings.
© Woodhead Publishing Limited, 2010
Desiccant materials for moisture control in buildings
15.7
373
Practical applications of commercial desiccants
Examining ventilation rates of occupants in non-domestic buildings leads to the conclusion that the rates recommended were not determined by the respiratory needs of people (i.e. 0.015–0.10 l/s/m²), as various bodies recommend a minimum ventilation rate around 1.20 l/s/m². The moisture content of ventilation air can be significant. Anyone who has experienced a hot, humid day will know the discomfort of perspiring without any cooling effect. This is due to a saturated atmosphere being unable to absorb any more moisture, and thus any excess we produce simply stays on us, unable to evaporate. Dalton’s Law of Partial Pressures clearly confirms this and for those of us who have forgotten, it is as follows: ∑ Each constituent in a mixture of perfect gases exerts the same pressure as if it alone were present in the space occupied by the mixture, at the temperature of the mixture. ∑ Total pressure of the gases is the sum of their partial pressures, and the volume of the mixture of gases is the same as the volume occupied by each gas at its partial pressure. ∑ Totally enthalpy of the mixture is the sum of the enthalpy of each constituent at its partial pressure. ∑ Barometric pressure represents the total pressure of atmospheric air. This total pressure is composed of all the partial pressures of all the constituents, chiefly nitrogen, oxygen and water vapour.
P = Pa + P g .
A typical person, who works in an office, produces latent heat of around 60 W at 24 ºC, which equates to 1.68 g/kg of moisture entering the atmosphere. Table 15.1 shows the effect of occupant density on dew point and humidity level. The Comfort Zone Chart, published in 1924 by American Society of Heating and Ventilating Engineers (ASHVE) after studying physiological reactions of temperature humidity and air movement, clearly set out the relationship between humidity and temperature in relation to comfort. Basically, as temperature increases, humidity had to reduce to maintain Table 15.1 The effect of occupant density on dew point and humidity level Density of people 1 1 1 1
per per per per
Latent gain (W/m²) Moisture inc. infiltration pick-up (g/kg)
10 m² 9.6 7.5 m² 11.3 5.0 m² 15.1 2.5 m² 26.1
1.8 2.12 2.64 4.9
Space air dew point (°C)
Space relative humidity (%)
9.0 9.6 10.0 14.1
45 48 50 65
© Woodhead Publishing Limited, 2010
374
Materials for energy efficiency and thermal comfort in buildings
the same relative comfort. Comfort lines similar to those in Fig. 15.7 were established in 1922. Humidity and the influence it has with regard to comfort and energy saving when cooling is required is not always considered seriously. Air distribution rules may be relaxed where lower moisture content ventilation air is introduced at/or near to room temperature. Asymmetric temperature gradients may be ignored with vapour pressure differential doing the work, taking us back to Dalton’s Law of Partial Pressures. Research and notable authors have concluded that a moisture content in air of not more than 7 g/kg is required to provide a healthy environment. This equates to a relative humidity of 40%, with a dry-bulb temperature of 23 ºC. Too dry an environment, generally below 30% RH, is not recommended. It is therefore of critical importance that the moisture within the air is properly considered and suitably controlled. The desiccant system accommodates just this problem. The psychrometric principals of a commercial desiccant system are illustrated in Fig. 15.8. Figure 15.9, shows an adsorbent (solid) desiccant air-handling system in summer, and Fig. 15.10 shows the desiccant air-handling system in winter. Both can be used in conjunction with the psychrometric description to demonstrate how a typical commercial desiccant system works. Fresh air enters through the filter and then passes over the desiccant wheel, which absorbs some of the moisture in the air, which also adds heat (approx. SHF 0.6). The drier but warmer air then passes to the thermal wheel which cools it down; it may be further cooled by an evaporative cooler, and depending upon the required final conditions, may be further cooled by means of a sensible cooling coil. The cooler, now dehumidified air is introduced to the space via an air supply fan, where it provides all the latent cooling Relative humidity (% RH) 100 80 60
40
25
Wet air temperature (°C)
20
15 0
10
0
10
15 20 30 Dry air temperature (°C)
15.7 Lines of comfort.
© Woodhead Publishing Limited, 2010
20
40
Desiccant materials for moisture control in buildings
375
Relative humidity (% RH) 100 80 60
40
25
20
Wet air temperature (°C)
A
15 0
E 0
20
10
10
D
C
15 20 30 Dry air temperature (°C)
B 40
15.8 Typical desiccant psychrometrics.
and some of the sensible cooling requirements depending upon which type of system is in use, either an all air, or air/water system. The warm, moist return air leaving the space by way of the filter is passed through the evaporative cooler. This cool now humid air enters the thermal wheel enabling the sensible cooling to be transferred to the incoming air, which in turn is being heated by the incoming air. A regenerative heater further increases the air temperature before entering the desiccant wheel where it regenerates the desiccant. Some of the air could bypass the regeneration heater and desiccant wheel to save energy. The system is environmentally friendly, using inert materials, i.e. salt, silica gel or titanium silicate, and can use direct or indirect gas, waste or solar heat to regenerate the desiccant. Desiccant wheels also have laminar flow characteristics, thus higher air volumes are permissible without an energy penalty. During the winter months when the desiccant wheel may be inactive there needs to be an additional consideration. As supply air flows through the desiccant wheel without reactivation, moisture will build up in the desiccant wheel. Excess moisture supports fungal growth within the core of the material. Thus when dehumidification is required, the warm, humid wheel can give off odours reminiscent of wet wool until the regeneration heat kills off the microbial growth accumulated when the wheel was inactive. A regular exercise and purging regime is recommended for the wheel to prevent the build-up of microbial growth. Commercial absorbent desiccant systems present a liquid to the air stream instead of a solid. This type of equipment is less common in a commercial application; however, it does provide some unique advantages. In a liquid system a solution of LiCl coats an extended surface similar to that of
© Woodhead Publishing Limited, 2010
376
Regeneration heater
Evaporator cooling
Filter
© Woodhead Publishing Limited, 2010
Discharge air
Hot humid air
Preheat
Filter
Desiccant wheel
Thermal wheel Summer
Evaporator cooling
Supply air fan
Temperature Moisture content
15.9 Desiccant air handling system: summer psychrometrics.
Materials for energy efficiency and thermal comfort in buildings
Exhaust air fan
Regeneration heater
Evaporator cooling
Filter
© Woodhead Publishing Limited, 2010
Discharge air
Cold dry air
Preheat
Filter
Desiccant wheel
Thermal wheel Winter
Evaporator cooling
Supply air fan
Temperature Moisture content
15.10 Desiccant air humidity system: winter psychrometrics.
Desiccant materials for moisture control in buildings
Exhaust air fan
377
378
Materials for energy efficiency and thermal comfort in buildings
cooling tower media. The air flows through the media and the air gives up its moisture to the liquid desiccant. The diluted liquid desiccant is then sent to a regenerator to have its excess moisture, equal to the moisture taken out of the air, removed. The dilute liquid is first heated then put in contact with a small amount of outdoor air; the hot liquid desiccant releases its moisture to this regeneration air. The re-concentrated liquid desiccant flows back to the media where the process is repeated. Control of the temperature and concentration of the solution enable the air to leave the liquid desiccant system at the precise temperature and moisture content needed without the after-cooling required by the dry adsorbent system of a desiccant wheel. Around the world, over the past decade, desiccant cooling systems have advanced through development in polymer technology and novel developments in heat exchanger technology. These novel heat exchanger applications provide products that can heat and cool, both air and water, as well as recycle sensible and latent energy in a very efficient manner (Fig. 15.11). These novel desiccant cycles have more than doubled the coefficient of performance (energy efficiency ratio) of desiccant cooling systems. They are up to three times more energy efficient than conventional (Pennington) systems when operating on low temperature heat such as that from solar heat collectors, fuel cells or combined heat and power (CHP) systems.
15.8
Practical applications of natural desiccants for modifying building humidity
An alternative approach is to use the water absorption properties of building materials. The advantage of using water absorbing materials as a buffer during brief periods of increased water vapour is that during these periods the absorbent material may be used as a substitute for mechanical ventilation. The heat of evaporation being recovered by the heat of absorption released by the material provides for increased comfort. The use of porous materials in walls, floors and ceilings may be used as a buffer to maintain relative humidity. Hygroscopic walls, floors and ceilings can aid stability of relative humidity and thus comfort, especially in rooms which are ventilated to less than 1 ac/h. A few centimetres of absorbent material are sufficient to buffer a daily RH cycle and about 40 cm of absorbent wall might buffer an annual cycle in a room with about 0.1 ac/h. The defining factors are the water capacity and permeability of the absorbent materials used. The common buffer building materials are wood, cut across the grain, and unfired clay brick. A specially designed lightweight clay made from bentonite mixed with perlite also gives an excellent performance (Padfield, 1998).
© Woodhead Publishing Limited, 2010
Desiccant materials for moisture control in buildings
379
6
1
4 5
3 Combine 3 processes Heat exchange Indirect evaporate cooling Dehumidification
15.11 Novel desiccant system.
The best performer of the commonly used building materials is cellular concrete. Most other building materials have a negligible effect at moderate relative humidity. Cellular concrete is made by mixing silica, calcium oxide, aluminium powder and water. The end result is a mass of interlocking needle crystals of calcium aluminium silicate with relatively large air voids and a typical density of 750 kg/m3. These air voids provide plenty of sites for water absorption, making cellular concrete a moderately good buffer material. Figure 15.12 shows a typical absorption and desorption cycle. The combination of porous materials laid over porous absorbent materials is interesting. A combination of gypsum plaster over cellular concrete provides a sort of a diode as it allows moisture to penetrate but hinders its return. The gypsum plaster conducts liquid water, because it is wettable and has a
© Woodhead Publishing Limited, 2010
380
Materials for energy efficiency and thermal comfort in buildings 100
80 End grain wood
RH
60
Cellular concrete
40
20
0
12
24 Hours
36
48
15.12 Absorption and desorption cycle.
system of large pores. The cellular concrete has a similar structure on a finer scale and retains the water. This combination can only be advantageous if the cellular concrete can evaporate the moisture to the outside of the building. The need to ventilate away moisture generated by human activities could be reduced by utilizing porous and absorbent materials to buffer the moisture and thus use a lower ventilation rate and less energy. In some instances this buffering may be so effective that mechanical systems are not necessary. However, in other circumstances the average RH provided by the passive buffers will be too variable and a relatively small and simple air conditioning system may assist the material buffers during the time of peak moisture gain. There are no readily available design tools to explore the use of porous or absorbent materials to moderate indoor climate. However, when the room has absorbent buffers, the RH can be defined by the interaction of the materials with the various sources of water vapour within the room, as the RH is a consequence of the behaviour of the materials, not a controlling parameter. The sorption curve of a material defines how much water will be released or absorbed when the material moves from equilibrium with one RH to another. The inverse argument is that this same curve also defines RH change in the air that surrounds the material resulting in the material losing a certain weight of water into the space. Where there is a reasonably even and moderate RH, only that portion of the absorption curve is relevant, i.e. between 40 and 65% RH. This part is fairly straight for most materials, so the absorption curve can be replaced by a constant: the water capacity. The water capacity is defined as the weight of water that would be released from one cubic metre of material if the RH changed from 100 to 0%, assuming
© Woodhead Publishing Limited, 2010
Desiccant materials for moisture control in buildings
381
a sorption curve gradient constant at the value for 50% RH. Water vapour permeability is also a factor. The higher permeability makes for a better performance as a buffer; however, there are other considerations when the RH is changing: as the water vapour diffuses into the material it is attracted to the pore walls by van der Waals forces, according to its absorption coefficient. A material with both high permeability and high absorption will actually show a low permeability to water vapour under dynamic circumstances, because the water is absorbed before it is diffused. Calculation of this complex process is aided by defining a unit called diffusivity, which is the diffusion coefficient divided by the absorption coefficient. This is used to calculate an active depth for moisture exchange.
d=
Dt tt
where ‘d’ is the active depth of water exchange, ‘t’ is the period of the water flux cycle and ‘D’ is the diffusivity. The active depth marks the distance into the wall at which the variation in RH in the pores has fallen to about one third of the variation in the room (Claesson and Hagentoft, 1994). Unfortunately, the analogy between heat and moisture flow is not exact. Therefore the effective depth is just an indication of the order of the useful thickness of the material for buffering relative humidity. The amount of water available is now obtained by multiplying the water capacity by this active depth. The best materials are not those generally used in building. Wood cut Water
High
Capacity
Diffusion coeff.
Clay perllite
Wool
Wood
Active depth
Available water
Lime mortar
Wood across grain
Gypsum plaster Wood across grain
Brick
Clay perllite
Gypsum board
Low
Cellular concrete
Gypsum board
Gypsum board
Cellular concrete
Gypsum plaster
Clay perllite
Cellular concrete
Wool
Wood across grain
Cellular concrete
Clay perllite
Gypsum plaster
Gypsum board
Wool
Lime mortar
Brick
Gypsum plaster
Brick
Lime mortar
Brick
Lime mortar
Wood
Wood
Wood
15.13 Performance comparison of typical building materials.
© Woodhead Publishing Limited, 2010
382
Materials for energy efficiency and thermal comfort in buildings
across the grain is by far the best buffer but may not be ideal because it outgases a variety of corrosive vapours. Clay is the second best, but some give off hydrogen sulphide. Clay walls smell much less than wood, as the hydrogen sulphide normally oxidizes to hydrogen sulphate. The active depth of clay for a daily cycle is 5 mm. Figure 15.13 provides a synopsis of the above. Absorbent walls, floors and ceilings can significantly improve climatic stability of indoor spaces that have low ventilation rates. Thus, moisture mass must have equal consideration to thermal mass in passive buildings.
15.9
Bibliography
ASHRAE Publication (1992) Desiccant Cooling and Dehumidification. ASHRAE Guide (2007) Fundamentals – Chapter 22. Beggs, Warwicker. ‘Towards zero carbon dioxide emission: the environmental impact of fabric thermal storage in UK office buildings’. www.warwicker.com Beggs, Warwicker, Howarth (1995) ‘Elimination of air conditioning in existing buildings through fabric thermal storage: A Theoretical study’. Building Serv. Eng. Res. Technol. 16(4) 215–220 www.warwicker.com Brundrett G. W. (1990) Criteria for Moisture Control, Butterworth’s, CIBSE Desiccants the Future – Robert van Zyl Professor of Engineering, Professor Brian Warwicker. www.warwicker.com CIBSE Guide Volume A, Section A7 (2006). CIBSE Guide Volume B, Section B2 (2005). Claesson, Johan and Hagentoft, Carl-Eric, (1994) ‘Basic building physics – mathematiucal modelling. University of Lund, Department of Building Science. Evans B. (1995) ‘New cooling for old buildings.’ Architect Journal May. www.warwicker. com Harriman, Brundrett, Kittler, ASHRAE Publication (2001) Humidity Control Design Guide. Padfield. The role of absorbent building materials in moderating changes of relative humidity. October 1998. Redman B. (1997) ‘Dehumidifying using Desiccants’; CIBSE Journal, June. Warwicker B. P. (1989), ‘Low Temperature Air and Ice Storage’; CIBSE Journal, February. www.warwicker.com Warwicker B. P. (1995) ‘Low Humidity Air & Air Conditioning’; CIBSE Journal, November. www.warwicker.com World Health Organisation Report, Bilthoven, Nederlands. ‘The Right to Healthy Indoor Air’ 15–27 May 2000. Wood Science and technology Journal (1995) Volume 29, Number 5/August.
15.10 Appendix: Energy efficiency ratio (EER) and coefficient of performance (COP) Energy efficiency ratio (EER) is used in the USA, and is defined as the system output in Btu/h per watt of electrical energy. Coefficient of performance
© Woodhead Publishing Limited, 2010
Desiccant materials for moisture control in buildings
383
(COP) is the equivalent measure using SI units, which is widely used in the UK. A COP of 1.0 equates to an EER of 3.4. When comparing technologies that use electrical energy with those that use heat energy, it is useful to consider the ‘equivalent COP’ that achieves the same carbon emission levels. In the UK the generation of electricity emits 2.6 times as much carbon per watt when compared with burning natural gas. In terms of carbon emissions, therefore, a heat driven device with a COP of 2.5 would be equivalent to an electrically driven device with a COP of 2.5 ¥ 2.6 = 6.5. The seasonal energy efficiency ratio (SEER) used in the USA and equivalent ‘seasonal COP’ is a measure of the annual energy efficiency taking into account the varying weather conditions. It is calculated using weather ‘bin’ values, with a given frequency of occurrence in each temperature ‘bin’. Very high SEER (and seasonal COP) values can be expected with new desiccant cycles, as for a large part of the year no dehumidification is required and no regeneration heat is used. The SEER system is flawed, however, in that it does not consider the external humidity and therefore the requirement for dehumidification is not quantified. Until a standard is set, an objective view cannot be taken on what SEER to expect for desiccant cycles, but the SEER for novel desiccant systems could well be equivalent to an electrically driven device with a SEER in excess of 30, which is up to three times better than that of conventional air-conditioning systems.
© Woodhead Publishing Limited, 2010
16
Phase change materials for energy storage and thermal comfort in buildings
M. M. F a r i d and A. S h e r r i f, University of Auckland, New Zealand
Abstract: This chapter reports on recent research conducted on the use of phase change materials (PCM) for thermal comfort and heating and cooling peak load shifting in buildings. The objective here is to show experimentally and through a computer simulation that PCM impregnated in building materials can provide thermal energy storage benefits. Paraffin (RT20) has been used as the PCM because of its desirable thermal and physical attributes including its melting temperature of 20–22 °C, which is close to human comfort temperature. The PCM was impregnated into gypsum wallboards to produce an efficient thermal storage medium (PCMGW), which consists of 26%-wt PCM impregnated in gypsum boards. This PCMgypsum wallboard structure was tested in-situ in an office size building. In parallel, a thermal building simulation code (SUNREL) was used to simulate the performance of the office size rooms. Measured and simulated results in summer showed that the use of PCMGW effectively reduced diurnal daily fluctuations of indoor air temperatures and maintained the indoor temperature at the desired comfort level for a longer period of time. A major benefit of thermal energy storage in winter is to reduce electricity demand charges by limiting the need to run electrically operated heating and airconditioning devices during peak load periods. This study reveals that this application of PCM storage in buildings can lead to healthier interior spaces, and more efficient energy use in terms of demand charge reduction and use of favourable off-peak rates. Key words: PCM, peak load, comfort in buildings, paraffin wax, gypsum wallboard.
16.1
Introduction
The likelihood of a shortfall in future availability of non-renewable energy, which powers much of modern society, is increasing. It is advisable to consider the use of building materials that minimize the need for space conditioning while maintaining comfortable and healthy internal environments [1]. The fluctuation of indoor air temperature, which is a consequence of the low thermal mass of lightweight buildings, plays a special role among other factors influencing thermal comfort. It can be considered as the single largest cause of complaints from occupants in modern buildings constructed using lightweight building materials [2]. 384 © Woodhead Publishing Limited, 2010
Phase change materials for energy storage and thermal
385
Thermal energy storage in buildings, which has received an increasing attention, seems to provide better thermal comfort for occupants and ensure efficient energy use. The need for air-conditioning could be minimized through an effective incorporation of phase change materials (PCM) into building materials, which also enables strategies for electricity peak-load shifting. The use of PCM will also allow the passive capture of solar energy when it is available, which can then be stored and used later when there is a demand for it. The work presented in this chapter shows how well PCM building materials could perform in real buildings in New Zealand. Full-scale office size buildings constructed using normal and PCM-impregnated gypsum wallboard are used for that purpose.
16.2
Background
Research on PCMs and methods of thermal energy storage (TES) in buildings was initiated and encouraged by the US Department of Energy in 1982 to demonstrate the benefits of utilizing latent heat of PCMs in term of reducing variation in indoor temperature (thermal inertia) in lightweight constructions [3]. Later, many researchers confirmed the effectiveness of PCMs in improving energy efficiency and indoor thermal comfort of buildings based on numerical simulations and experimental studies [4]. In particular, Athienitis et al. [5] and Schossig and Hennin [6] carried out extensive studies in full-scale office size rooms, which were constructed using PCM building materials. It was shown that these materials could function efficiently as a thermal storage medium. Recently, Cabeza et al. [7] used microencapsulated PCM in a real size concrete cubicle and compared its performance with a control concrete cubicle containing no PCM. They showed an improved thermal inertia and efficient energy use in the PCM cubicle. Comprehensive reviews on the PCM thermal energy storage in buildings have been adequately discussed in the literature [8]. Another application of TES is peak-load shifting to take advantage of the off-peak electricity tariffs. There is a growing interest in the use of daily TES for electrical load management in both new and existing buildings. The TES technology has matured and is now accepted internationally as a proven energy conservation technology [9]. A simplified sketch in Fig. 16.1 is given by Dincer [10] to show different strategies for charging and discharging TES to meet cooling demands during peak demand hours. The full-storage strategy, which is sketched in Fig. 16.1(a), shifts the entire peak load to off-peak hours. This strategy is most attractive and likely to be economically advantageous only when spikes in the peak load curve are of short duration [11]. In the partial-storage strategy (Fig. 16.1(b)), equipment operates to meet part of the peak-load and the rest is met by drawing energy from storage. On mild
© Woodhead Publishing Limited, 2010
386
Materials for energy efficiency and thermal comfort in buildings
Tons
Reduced on-peak demand
C
C
C
A B
A B
C
B
24 hours daily cycle A: storage meets load B: chiller meets load directly C: chiller charging storage (a)
24 hours daily cycle Dotted line: chiller on Solid line: load (b)
16.1 Operating strategies: (a) full storage; (b) partial-storage [10].
spring or autumn days the partial-storage system designed for space heating at winter design temperatures may function as a full-storage system with a full peak demand shift. Promising results of peak-load shifting by using the concepts of TES have encouraged investigators to put more effort in energy efficiency and conservation.
16.3
Selection of phase change materials (pcm) and fabrication of pcm-gypsum wallboards (pcmgw)
A comprehensive list of possible material that may be used for latent heat storage are reported by Abhat [12]. Readers who are interested in such information are referred to the papers by Lorsh et al. [13], Lane et al. [14], Humphries and Griggs [15] and more recently by Khudhair and Farid [8] who have reported a large number of possible candidates for latent heat storage covering a wide range of temperatures. Paraffin compounds undergo negligible supercooling, are chemically inert and stable with no phase segregation. Pure paraffin waxes are very expensive; therefore only technical-grade paraffin should be used. Paraffin waxes are essentially available as linear alkyl hydrocarbons at almost any temperature. Furthermore, the paraffin waxes are non-polar materials; they are not subject to hydrogen bonding with other polar components of the building materials. Fatty acids and their esters can also be used as more environmentally friendly PCMs; however, they have lower latent heat than paraffin. Feldman and Shapiro [16] have analysed the thermal properties of fatty acids (capric, lauric, palmitic and stearic acid) and their binary mixtures. The results have shown that they are attractive candidates for latent heat thermal storage in space heating applications. The melting range of the fatty acids was found to
© Woodhead Publishing Limited, 2010
Phase change materials for energy storage and thermal
387
vary from 30 °C to 65 °C, while their latent heat of transition was observed to vary from 153 to 182 kJ/kg. Hydrated salts are attractive materials for use in thermal storage due to their high volumetric storage density (~350 MJ/m3), relatively high thermal conductivity (~0.5 W/m °C) and moderate costs compared to paraffin waxes, with few exceptions [8]. However, the high storage density of these materials is difficult to maintain and usually decreases with cycling. This is because most hydrated salts melt congruently with the formation of lower hydrated salt, making the process irreversible, leading to the continuous decline in their storage efficiency. Subcooling is another serious problem associated with all hydrated salts. A number of companies have successfully succeeded in solving these problems and commercialized CaCl2·6H2O encapsulated in different forms of containments to be used as a PCM. To allow safe and straightforward application of PCMs in different environments (e.g. within plasterboard of residential housing) they can be microencapsulated as micron-sized particles with a polymer shell as a coating [17]. This eliminates any possibility of leakage and diffusion of the liquid PCM or evaporation of volatile components over time. The microencapsulation also reduces the flammability of the PCM. The microcapsules can be easily incorporated into many systems to reduce energy consumption and maintain temperatures at a comfortable level. Prime examples include heat transfer media in heating and cooling systems or heat storage media in insulating and building materials. The commercial paraffin, RT20, was selected as a suitable PCM in this study mainly due to its melting temperature, which is close to human comfort temperature. Paraffin RT20 is stable, chemically inert and possesses a good level of latent heat. Thermal energy storage characteristics of PCMs are most accurately evaluated by using differential scanning calorimetry (DSC) analysis. DSC graphs in Fig. 16.2 show that paraffin RT20 has a melting range of 18.1–21.5 °C and a reasonably high latent heat of fusion of ~162.5 kJ/kg. RT20 melts and solidifies within a narrow temperature range so that the stored heat may be released over a limited temperature swing that must be maintained inside buildings. Repeated 100 melting/freezing cycles were conducted on samples of RT20 to study the changes in the thermal properties. The results showed that this commercial paraffin has good thermal properties and undergoes congruent melting and freezing with no supercooling. A most flexible process whereby the PCM can be incorporated into gypsum wallboards is the immersion process, which does not interfere with the manufacturing processes of the gypsum wallboards. It involved dipping the stocks of the gypsum wallboards in molten PCM. The process was found easy to control and susceptible to a wide variation of process conditions such as PCM temperature and immersion time. Impregnation of
© Woodhead Publishing Limited, 2010
388
Materials for energy efficiency and thermal comfort in buildings
24 21
10th Cycle: Peak 18 °C, Heat 162.5 kJ/kg 50th Cycle: Peak 17.75 °C, Heat 161 kJ/kg 100th Cycle: Peak 18.15 °C, Heat 162 kJ/kg
10th Cycle
18
50th Cycle 100th Cycle
15 12 Heat flow (mW)
9 6 3 0 –3
0
5
10
15
20
25
30
35
40
45
50
55
–6 –9
–12 –15
10th Cycle: Peak 21.8 °C, Heat 162.4 kJ/kg 50th Cycle: Peak 21.9 °C, Heat 162.7 kJ/kg 100th Cycle: Peak 21.8 °C, Heat 162.5 kJ/kg
–18 –21 –24
Temperature (°C)
16.2 DSC graph of RT20 after a number of thermal cycles. 28 26
Percentages of PCM-uptake
24 22 20 18 16 14 12 10 40 50 60 70 80
8 6 4 2 0
0
1
2
3
4
5 6 7 Time (minute)
°C °C °C °C °C
8
PCM PCM PCM PCM PCM
molten molten molten molten molten
9
10
bath bath bath bath bath
11
12
16.3 Effects of immersion time and PCM temperatures on the PCM absorptivity into 13 mm thick gypsum wallboards.
the gypsum wallboard with 24–26% by weight of RT20 was achieved by immersing ordinary gypsum wallboards (60 ¥ 60 ¥ 1.3 cm) for 10 minutes in a bath filled with molten RT20 at 70–80 °C. Figure 16.3 shows that the rate of paraffin uptake into the gypsum wallboards increases with PCM temperature. The rate of paraffin uptake was very high during the first three
© Woodhead Publishing Limited, 2010
Phase change materials for energy storage and thermal
389
minutes but diminished gradually after 10 minutes of immersion time. The alternative to this method is to microencapsulate the paraffin with a polymer. The microencapsulated product can then be mixed with the gypsum during manufacturing. This will prevent any possible migration of the paraffin from the board but will add cost that has prevented its commercial use up to now.
16.4
Full-scale testing facilities
A full-scale facility consisting of two identical office size constructions were built at the Tamaki Campus of the University of Auckland, New Zealand with the view to conduct long-term thermal performance involving monitoring and modelling work. A schematic plan view of the test room is shown in Fig. 16.4. The interior walls and ceiling of the first office (ORD) were finished with ordinary gypsum wallboards while the interior walls and ceiling of the second office (PCM) were finished using PCMGW. Each office in the test facility is a single-storey design of a typical lightweight construction. They measure 2.6 ¥ 2.6 ¥ 2.6 m giving a floor area of 5.76 m2 each. Wooden frames made of 9.8 ¥ 6.3 cm dressed pine timber were used in the construction. The interior coverings were sets of either gypsum wallboards or PCMGW panels (60 ¥ 60 ¥ 1.3 cm) mounted
1200
1100
2500
2600
1200
EQ
2400
94 mm Insulation
EQ
Electricity board
800
Door 760
*All constructions comply with NZS 3604 North
**All measurments in mm
16.4 Schematic plan view of the test room.
© Woodhead Publishing Limited, 2010
390
Materials for energy efficiency and thermal comfort in buildings
on the wooden frame. The exterior walls were 1.25 cm thick sheets of plywood. The wall cavities were filled with fibreglass thermal insulation. The insulation is installed with no gaps and no folds so as to achieve high thermal resistance to heat flow. The thickness of the insulation is 9.4 cm for both the walls and ceilings. The test facility faces north to maximize sun exposure, as this is a key aspect of energy-efficient building design. Each office was supplied with one window facing north. The two constructions were situated in a large open area with a 4.2 m distance between them, free from any shading. The test facility was provided with a computer-controlled data acquisition system with 20 data channels. The system consisted of a data recorder connected to a modem for data remote downloading. In addition to the temperature measurements inside and outside the offices, relative humidity, wind speed and solar radiation were also continuously measured and recorded.
16.5
Benefits of applying thermal energy storage
16.5.1 Thermal comfort in summer season For the sake of clarity, only the results obtained over a seven-day period in January 2005 are presented here for discussion. Figure 16.5 shows measurements of solar radiation and wind speed in Auckland, New Zealand. The solar radiation exceeds 1000 W/m2 during the peak sunshine hours on all days. A large portion of New Zealand has at least 2000 hours of sunshine a year. The two offices were not supplied with any active cooling in order to Solar radiation Wind speed
10 9
1100 1000 900 800
8
700 600 500 400
5
300 200 100 0
2
7 6
4 3
1 0
12
24 36 48
0 60 72 84 96 108 120 132 144 156 168 Time (hour)
16.5 Summer readings of solar radiation and wind speed.
© Woodhead Publishing Limited, 2010
Wind speed (m/s)
Solar radiation (W/m2)
1400 1300 1200
Phase change materials for energy storage and thermal
391
accurately compare the performance of ordinary gypsum wallboards and PCMGW and their effects on the fluctuation of the indoor air temperatures in a real, albeit somewhat controlled, situation. Figure 16.6 shows that, in the PCM room, as the indoor air temperature rises passively to within the solid–liquid phase change temperature, the PCM begins to melt by absorbing heat from the room and storing it principally as a latent heat of melting. Thus, the PCMGW acts as a cooling medium. On the other hand, in the ORD room, the temperature rises much more steeply and reaches a higher level because only sensible heat storage is available. When the indoor air temperature falls below the PCM transition temperature, the PCM begins to solidify in the PCMGW, partially or completely, releasing the stored latent heat. The thermal behaviour of the wallboards affects significantly the indoor air temperatures of the room over the seven-day period. The temperatures in the PCM room rises at a lower rate during the day compared to that of the ORD room. At night, the temperature in the PCM room is higher than that in the ORD room. The ORD room maintained a wider range of weekly-averaged indoor air temperature compared to the PCM room, as shown in Table 16.1. It appears that the need for mechanically assisted cooling in the summer season in Auckland could be eliminated or reduced to a large extent through the use of PCMGW. The weekly-averaged indoor air temperature in the ORD room varied by 10.6 °C, while the corresponding variation was only 5.1 °C in the PCM room. Thus, the stored thermal energy in the form of latent heat has effectively 30
Ambient air temp (°C) ORD indoor air temp (°C) PCM indoor air temp (°C)
28
Temperature (°C)
26 24 22 20 18 16 14 12 10
0
12
24
36
48
60
72 84 96 108 120 132 144 156 168 Time (hour)
16.6 Summer ambient and indoor temperatures in the two rooms.
© Woodhead Publishing Limited, 2010
392
Materials for energy efficiency and thermal comfort in buildings Table 16.1 A comparison of measured weekly-averaged indoor air temperatures in the test rooms ORD room
DTORD
PCM room
DTPCM
28.1 °C–17.5 °C
10.6 °C
25.7 °C–20.6 °C
5.1 °C
reduced the variation of the indoor air temperature within the PCM room. The general notion is that if PCM is integrated into the walls and ceilings, it will act as a thermal reservoir and prevent excessive rise or fall of the indoor air temperature. As a result, it leads to a reduction in the overheating hours and hence in the cooling loads in summer, and yet provides a comfortable indoor atmosphere.
16.5.2 Peak-load shifting in winter season On sunny days in winter, the use of PCM in the wall and ceilings of buildings will allow the capture of solar radiation during the day for later use at night. However, on predominantly cloudy or foggy days, the indoor air temperature in both rooms did not reach the melting range of the selected PCM. Consequently, there was no stored energy and hence no major benefit was observed from using the PCMGW. When an internal heating system is supplied, there is potential for use of the high storage density of the PCM in the walls and ceiling for electrical peak-load shifting. This will allow some reduction in the cost of electricity by shifting electrical heating (in winter) and cooling (in summer) demands to periods when electricity prices are lower, for instance during the night. Thus the main application of thermal energy storage in winter would be to capture solar energy and reduce electrical demand charges by peak-load shifting. The indoor and ambient temperatures were monitored, collected and analysed during the month of July 2006, which is usually the coldest month in Auckland. For the sake of clarity, only the results obtained over two specific days (18 and 19 July), which are representative of typical cloudy and cold days in Auckland, are presented. Figure 16.7 shows the measured solar radiation and wind speed. A 5-fin oil radiator electrical heater with a power setting of 1 kW was used in each room. The heaters were programmed to turn on from 1:00 am to 7:00 am (off-peak period) every night, using a digital timer. In the PCM room, when the indoor air temperature rose to within the solid–liquid phase change temperature, the PCM melted in the PCMGW by absorbing heat from the room. At 7 am the heaters in both test rooms were turned off. Subsequently, the indoor air temperature fell below the PCM transition temperature, the PCM solidified in the PCMGW, completely or partially, and the stored latent heat was released. The heating load needed during the day
© Woodhead Publishing Limited, 2010
Phase change materials for energy storage and thermal 450
393 10
Sunshine Wind speed
400
9 8
Solar radiation (W/m2)
350
7
Wind speed (m/s)
300
6
250
5
200
4
150
3
100
2
50
1
0
0
4
8
12
16
20 24 28 Time (hour)
32
36
40
44
48
0
16.7 Winter readings of solar radiation and wind speed. 28 26 24
Temperature (°C)
22 20 18 16 14 12 10 8
Ambient air temp. ORD indoor air temp. PCM indoor air temp.
6 4
0
4
8
12
16
20 24 28 Time (hour)
32
36
40
44
48
16.8 Winter ambient and indoor temperatures in the test rooms.
in winter was reduced while the thermal load was met with the released heat from the PCM. Figure 16.8 shows that the variation in the indoor temperature was reduced significantly by the application of PCM. Figure 16.8 shows that thermal storage is often advantageous in facilities where there is a limited number of peak demand hours every day. Office
© Woodhead Publishing Limited, 2010
394
Materials for energy efficiency and thermal comfort in buildings
buildings with no heating demands overnight and high heating demands in the morning hours, exhibit the optimum profile for this application of thermal energy storage.
16.6 Computer simulation 16.6.1 Thermal building model It was necessary to conduct a computer simulation of the buildings so that the idea of using PCM could be tested in future at any location worldwide. SUNREL version 1.04 is technical software used for building energy simulations based on finite difference approaches to model active or passive building elements. It is an upgrade to SERIRES version 1.0 that was written under the guidance of the Solar Energy Research Institute (SERI), now the National Renewable Energy Laboratory (NREL) at Golden, CO, USA. The upgrade of SERIRES to SUNREL was completed by Colorado State University and NREL. SUNREL has been tested satisfactorily through experimentation using the procedure of the International Energy Association [18]. A development of thermal models for buildings is required to arrive at optimal design parameters especially with regard to the required thermal mass. It is well known that thermal models of buildings depend in a complex way upon many interrelated factors. But using an appropriate level of detail in the SUNREL program depends primarily on the nature of the desired outputs and the applications under study. The basic descriptive constructs provided by SUNREL for developing the thermal models will be created within the constraints of the program. Given the correct input parameters that cover different aspects of the building size, construction, and location, SUNREL is, therefore, able to internally convert them to a mathematical form suitable for numerical solutions. The SUNREL simulation software uses the concept of ‘thermal zone’ to define thermal properties necessary for the simulation of a specific area. The thermal zone is either a single room or a group of rooms. Usually, a building is represented as one or more thermal zones with thermal communications (heat flow) between them and with the ambient including solar radiation. The most common paths of thermal communications are windows and walls including those walls with special constructions such as layers of PCMs. The wall construction consists of up to 10 layers from inside to outside. The layers of the walls are usually composed of different building materials and insulations in the ‘ORD’ case, which does not contain PCM materials. In the ‘PCM’ case, the layers of the walls include PCM in addition to the building materials and insulations. Within the SUNREL program, the most important requirements are the building materials of the wall. Figure 16.9 shows the main configuration used to construct the walls and the ceiling in
© Woodhead Publishing Limited, 2010
Phase change materials for energy storage and thermal
395
Siding
Insulation
External side
Internal side
Gypsum boards
Wood
16.9 A schematic of hypothetical four layers of the walls in the ‘ORD’ case. Table 16.2 Thermo-physical properties of the mass types used in the ‘ORD’ case Mass name
Conductivity (W/m K)
Density (kg/m3)
Specific heat (kJ/kg K)
Thickness (m)
Board Insulation Wood Siding
0.25 0.038 0.12 0.094
670 32 510 640
1.089 0.835 1.38 1.17
0.013 0.075 0.025 0.01
Table 16.3 Thermo-physical properties of the PCM used in the ‘PCM’ case Conductivity (W/m K)
Density (kg/m3)
Specific heat (kJ/kg K)
Latent heat (kJ/kg)
Melting point (°C)
Thickness (m)
0.2
810
2.1
172
20
0.004
the simulations of the ‘ORD’ case. Four layers have been used to construct the walls and the ceiling. From the internal to the external side, the layers are gypsum wallboards, insulation, wood and siding. The physical properties of each material, used to make the wall construction, have been defined. The thermal conductivity, density, specific heat and thickness of each layer are listed in Table 16.2. The PCM type has been defined based on its heat of fusion and melting point in addition to the foregoing properties as listed in Table 16.3. Composite walls, such as a typical wood framed wall with stud and insulation may be modelled either as two separate walls belonging to the same exterior surface or two consecutive layers in one wall, as is the case here. In the PCM case, the same configuration of the construction of the walls has been used with the addition of a PCM layer that is placed between two
© Woodhead Publishing Limited, 2010
396
Materials for energy efficiency and thermal comfort in buildings
layers of the gypsum wallboards. The two layers of the gypsum wallboards are identical in all physical and thermal properties. The combined thickness of the two layers of the gypsum wallboards used in the PCM case is equal to that of the gypsum wallboards used in the ORD case.
16.6.2 Computer predictions using the SUNREL software SUNREL thermal simulations have some limitations and these are related to the methods of calculating the effect of actual thermal mass in the interior environment and random behaviours of real occupants. Thermal mass is not only present in the building structure, but also in occupants and furniture within the building. Although SUNREL deals with these details in a systematic manner and allows estimating these thermal masses in a certain way, there are generally large uncertainties in the description of the real situation in the simulation input files. Other uncertainties include the method SUNREL uses to calculate the effect of latent heat of the PCM that melts and solidifies at a fixed temperature, while commercial PCMs melt and solidify within a range of temperatures (generally ~5 °C or higher). Also, SUNREL deals with the PCM as a layer placed between multi-layers of building materials, which does not represent the actual situation when the PCM is impregnated and is uniformly distributed within the pores of the building materials. It is, therefore, important to examine the validity of the SUNREL model against real experimental measurements. This can be accomplished by making a comparison between the measured data of the real test rooms and simulation results of the thermal zones, representing the test room, for at least a oneday period, and this was selected randomly as 15 February 2006. The main climatic measurements of hourly solar radiation, ambient temperature and wind speed of that day were used as input data for SUNREL. The results of the simulations were compared with those measured for both thermal zones as shown in Fig. 16.10(a-b). It can be seen that the simulation results (Fig. 16.10(b)) of the indoor temperature in both the ORD case and the PCM case are in a reasonable agreement with the measured data (Fig. 16.10(a)). This agreement between the theoretical and measured indoor temperatures shows that the latent heat of the PCM is well accounted for by the SUNREL simulation program.
16.7
Conclusions
The study presented in this chapter examined the benefits of thermal energy storage in buildings by means of incorporating PCM throughout the building materials. Paraffin RT20, as a PCM, was successfully impregnated into gypsum wallboards to form PCMGW of a significant thermal energy storage
© Woodhead Publishing Limited, 2010
Phase change materials for energy storage and thermal 32
397
Ambient air ORD indoor air PCM indoor air
30 28
Temperature (°C)
26 24 22 20 18 16 14 12
0 2 4 6 8 10 12 14 16 18 20 22 24 0 2 4 6 8 10 12 14 16 18 20 22 24 Time (hour) Time (hour) (a) (b)
16.10 Profiles of temperature of the ORD and PCM cases: (a) experimental results, and (b) simulation results.
effect. These PCMGW walls act as a heat storage or heat sink for trapping heat from the sun during daylight hours for using it later at night. In summer, measured thermal performances of the full-scale room that was constructed using PCMGW as interior surfaces, showed a significant reduction in the daily fluctuation of indoor air temperature (~5.5 °C), providing thermal comfort and healthier interior spaces compared to the control room containing no PCMGW. In winter, this application of PCM storage in buildings can lead to a significant improvement in the energy efficiency of the buildings in terms of use of favourable off-peak rates. Similar observations were obtained through the computer simulation conducted using SUNREL software.
16.8
References
1. R. Vale, ‘The role of insulation and thermal mass in the design of zero-heating homes’, PCM2003 Workshop, The University of Auckland, New Zealand, 2003. 2. P. O. Fanger, ‘Strategies to avoid indoor climate complaints’, ICBEM 1987, Polytechnique Romandes Press, Lausanne, Switzerland. 3. I. O. Salyer, ‘Thermal energy storage’, The DOE Energy Storage Research Activities Conference, 1989, New Orleans, pp. 97–110. 4. D. W. Hawes, D. Banu, D. Feldman, ‘Latent heat storage in concrete’, Solar Energy Materials, 1989, pp. 335–348. 5. A. K. Athienitis, C. Liu, D. Hawes, D. Banu, D. Feldman, ‘Investigation of the thermal performance of a passive solar test-room with wall latent heat storage’, Building and Environment, 1997, pp. 405–410.
© Woodhead Publishing Limited, 2010
398
Materials for energy efficiency and thermal comfort in buildings
6. P. Schossig, H. M. Hennin, ‘Encapsulated phase change materials integrated into construction materials’, Futurestock ‘2003’, Warsaw, Poland. 7. L. F. Cabeza, C. Castellón, M. Nogués, M. Medrano, R. Leppers, O. Zubillaga, ‘Use of microencapsulated PCM in concrete walls for energy savings’, Energy and Buildings, 2007, 39, 113–119. 8. A. M. Khudhair, M. M. Farid, ‘A review on energy conservation in building application with thermal storage by latent heat using phase change materials’, Energy Conversion & Management, 2004, pp. 263–275. 9. S. D. White, D. J. Cleland, R. Fraser, ‘Demand Side Response from HVAC&R’, AIRAH Energy Efficient Design Conference, November 2002, Sydney, Australia. 10. I. Dincer, ‘On Thermal Energy Storage Systems and Applications in Buildings’, Energy and Buildings, 34, 2002, pp. 377–388. 11. I. Dincer, M. A. Rosen, Thermal Energy Storage Systems and Applications, Wiley Inc., London, 2002. 12. A. Abhat, ‘Low temperature latent heat thermal energy storage; heat storage materials’, Solar Energy, 30, 1983, pp. 313–332. 13. H. G. Lorsh, K. W. Kauffman, J. C. Denton, ‘Thermal energy storage for heating and air conditioning: future energy production system’, Heat and Mass Transfer Processes, 1, 1976, pp. 69–85. 14. G. A. Lane, D. N. Glew, E. C. Clark, H. E. Rossow, S. W. Quigley, S. S. Drake, J. S. Best, ‘Heat of fusion system for solar energy storage subsystems for the heating and cooling of building’. Chalottesville, Virginia, USA, 1975. 15. W. R. Humphries, E. I. Griggs, ‘A designing handbook for phase change thermal control and energy storage devices’. NASA Technical Paper, 1977. 16. D. Feldman, M. M. Shapiro, ‘Fatty acids and their mixtures as phase-change materials for thermal energy storage’, Solar Energy Materials, 18, 1989, pp. 201–216. 17. M. C. Smith, M. M. Farid, A. J. Easteal, ‘Review of microencapsulated phase change materials for thermal energy storage applications’, IIR/IRHACE Conference, 16–18 February 2006, Auckland, New Zealand. 18. M. Deru, ‘BESTEST Results and SUNREL’, 1997, NREL, Version 1.0, Golden, CO, USA.
© Woodhead Publishing Limited, 2010
17
Porous materials for direct and indirect evaporative cooling in buildings
X. Z h a o, De Montfort University, UK
Abstract: This chapter investigates several types of porous materials that have potential to be used as heat and mass transfer media in indirect evaporative cooling systems, namely metals, fibres, ceramics, zeolite and carbon. The investigation identifies the most suitable material and structure. The magnitude of heat/mass transfer rates in relation to air conditioning applications was analysed, and the results showed that thermal properties of the materials, i.e., thermal conductivity and water retaining capacity (porosity), have little impact on system heat/mass transfer, and therefore, these two parameters have low importance in material selection. Instead, shape formation/holding ability, durability, compatibility with waterproof coating, contamination risk and cost are the most important concerns when selecting materials. Each material type was analysed based on the above criteria and the preferable structure and configuration illustrated. Comparing the different material types indicated that wicked (sintered, meshed, grooved or whiskered) metal plates (copper or aluminium) are the most suitable structure and material. Wicked aluminium sheet is much cheaper than copper and therefore more suitable for this application. Other potential applications of porous materials in building are also discussed. Key words: heat and mass exchange, material, thermal conductivity, porosity, shape formation, durability, compatibility, contamination risk, cost.
17.1
Introduction
17.1.1 Types of evaporative cooling systems Evaporative cooling utilizes the latent heat of water evaporation to cool air, either directly or indirectly. Direct evaporative cooling A direct evaporative cooling process is shown schematically in Fig. 17.1. A porous medium is made into thin layers which are arranged in parallel. The process air flows across the surfaces of the layers at a particular velocity, which causes water inside the voids of the porous layers to evaporate. In this process, the energy (enthalpy) in the air remains the same as no external energy is supplied, so the heat required for evaporation must come from the 399 © Woodhead Publishing Limited, 2010
400
Materials for energy efficiency and thermal comfort in buildings Wet channel
Air flow
17.1 Schematic of a direct evaporative cooling process.
Wet channel
Dry channel Working
Product
Wet channel
Dry channel
17.2 Schematic of an indirect evaporative cooling process.
air flow. As a result, warm dry air is changed to cool moist air in a quasiadiabatic process. The cooling effectiveness of this type of direct evaporative system ranges from 70% to 95% in relation to the incoming air’s wet-bulb temperature [1, 2]. However, it adds moisture to the air, making it only suitable for use in hot, dry climates or for spaces requiring humidification. Indirect evaporative cooling Indirect evaporative cooling lowers the air temperature without adding moisture to the air, making it more attractive than direct cooling, and is shown schematically in Fig. 17.2. In an indirect evaporative air cooler, primary (product) air passes over the dry side of a heat exchanging wall, while secondary (working) air passes over its opposite, wet side. The wet side absorbs heat from, and therefore cools, the product air through evaporation of water, while the latent heat of evaporation is transferred to the working, wet side air. Under ideal operating conditions, i.e., the product air travels in a counter flow to the working air and the two airstreams have a good balance of flow rates and an infinite contact area, the product air temperature on the
© Woodhead Publishing Limited, 2010
Porous materials for direct and indirect evaporative cooling
401
dry side of the heat exchanger would reach the wet-bulb temperature of the incoming working air, and the temperature of the working air on the wet side of the sheet would increase from its incoming dry-bulb temperature to the incoming product air dry-bulb temperature and be saturated. However, practical systems are far from this ideal. It has been suggested that only 50% of the incoming working air wet-bulb temperature can be achieved for a typical indirect evaporative cooling system [1, 3]. In recent years, an innovative indirect evaporative cooling process known as the dew point process has emerged (Fig. 17.3). This system results in greater temperature reductions than other methods of evaporative cooling, and allows the supply air to be cooled to a level below the wet bulb and above the dew point of the inlet air. It employs a perforated cross-flow heat and mass exchanger, and achieves a dew point effectiveness of 60 to 70%, and wet bulb effectiveness of greater than 100% [4]. The product air travels 1 2 Product channel
dp
3 Working
3¢
3¢
wet
channel
3¢
3¢
1 Working
dry
channel
Saturation line
1
3
dew: dew point 2: product air 3¢
3≤
Absolute humidity
1
3≤
3: working air 3≤ 3≤ 3≤
dew 3¢
3¢ 2 3¢
3¢
3¢
1
Dry-bulb temperature
17.3 Schematic of a dew point cooling system and its air treatment process in a psychrometric chart.
© Woodhead Publishing Limited, 2010
402
Materials for energy efficiency and thermal comfort in buildings
along a dry channel and its temperature is lowered from state 1 to 2 due to the heat transfer occurring between the dry channel and its adjacent wet channel, where water is saturated around the wall, causing a temperature difference between the dry and wet channels. In the meantime, working air at initial state 1 travels along the working dry channel but is gradually diverted into the adjacent wet channel. In the working air dry channel, the working air is also cooled, and at the turning point to the wet channel, its temperature is lowered to state 3, which varies with the location of the point along the travel path. When the working air turns into the adjacent wet channel, it flows backwards along the wet channel and quickly becomes saturated by the vapour evaporated from the wall, changing from state 3¢ to 3≤. It also receives the sensible heat from the dry channel, thus leading to a further change, from 3≤ to 3. A new type of polygonal exchanger for dew point cooling has been developed recently by the author [5]. A preliminary study indicated that the new exchanger could achieve an enhanced dew point effectiveness of up to 85%, which permits higher cooling volumes. Advances in dew point cooling technology open up the possibility of using evaporative cooling for air conditioning in buildings. A diagram of a polygonal exchanger is shown in Fig. 17.4.
17.1.2 Materials used for evaporative cooling Both direct and indirect evaporative cooling require a porous medium to allow heat and mass transfer between the water in the medium and the passing air, or between dry (product) and wet (working) air. The medium is formed into a plate and the air flows across it. The properties of the porous medium are important as these affect the cooling efficiency and performance of the evaporative cooling system. A range of porous materials can be used for this purpose, including metal, fibre, ceramics, zeolite and carbon. Metal materials used include metal foams, metal wools, sintered metals and wicked metal plates/tubes; fibres include paperboard and cloth (wood or glass); ceramics include SiC/SiC composites, zirconia ceramic, zirconia toughened aluminium, Al2O3, and aluminium nitride and polystyrene composites; zeolites include porous ceramics, molecular sieves and synthetic polymers; and carbon materials include carbon–carbon composites and activated carbon. Materials used for evaporative cooling should have high thermal conductivity and large moisture retaining ability, to allow a large amount of heat to be conducted from the air to the inside of the wall (for direct evaporative cooling), or from the dry side of the wall to the wet side, and an adequate amount of water to be retained within the wall. They should also be relatively inexpensive, suitable for shaping, easy to clean and replace, and resistant to bacterial growth on the wet surface.
© Woodhead Publishing Limited, 2010
Porous materials for direct and indirect evaporative cooling Hole
403
Sheet Working (discharged) air
Product (cooled) air
Wet
Dry channel air quid
channel air quid
Intake (product + working) air
Working (cooling air)
Working (discharged) air
Hole Extended Product (cooled) air
Sheet
Working (cooling) air Intake (product + working) air
17.4 The polygonal stack exchanger configuration.
Various materials were investigated to determine their suitability for evaporative cooling systems. The heat/mass transfer rates in relation to an air conditioning application were analysed, and the results used to judge whether the materials demonstrated viable heat and moisture transfer. A number of criteria, including thermal conductivity, water retaining capability, shape formation/holding ability, durability, compatibility with waterproof coating materials, contamination risk and cost, were applied in the search for a material that offered enhanced cooling effects with reasonable durability, low contamination risk and acceptable costs. The results are presented below, and the reader is also referred to the author’s paper published in the journal Building and Environment [6].
© Woodhead Publishing Limited, 2010
404
17.2
Materials for energy efficiency and thermal comfort in buildings
Assessing the capacities of evaporative cooling systems and the associated requirements in materials
The heat and mass transfer within an indirect evaporative cooling system is shown schematically in Fig. 17.5, and the process indicated by the psychrometric chart is shown in Fig. 17.6. When the product air (P) flows across the dry channel, it loses heat through the wall due to the temperature difference between the dry and wet sides. As a result, the temperature of the product air falls by a few degrees and its state changes from p1 to p2. In the meantime, water placed on the wet side of the wall evaporates by absorbing the sensible heat from air in the dry/wet channels and the vapour generated is removed by the airstreams across the wet channel. As a result,
W2
W1
P2
P1
17.5 Indication of heat and moisture transfer in an indirect evaporative cooling system.
W1
Absolute humidity
Saturation line
W2
P2 W1
P1
Dry-bulb temperature
17.6 Psychrometric diagram indicating the heat and moisture transfer in an evaporative cooling system.
© Woodhead Publishing Limited, 2010
Porous materials for direct and indirect evaporative cooling
405
the moisture content of the working air rises gradually until a saturated state is achieved (W1 to W1,w). Thereafter, the working air continues to attract moisture and its temperature rises, while its state moves along the saturation line (from W1,w to W2). The cooling efficiency of the indirect evaporative cooling system is defined as:
h=
T p1 – T p2 T p1 – Tw11,w
17.1
The cooling efficiency will depend largely on the logarithmic average temperature difference (DTm) between the two airstreams. The larger the DTm, the higher the cooling efficiency will be. The definition of DTm can be expressed as follows: DTm =
DTmax – DTmin DT ln max DTmin
17.2
at any position in the channels, heat transfer from the dry airstream to the wet surface of the wall can be expressed as: q = Us(Tp – Tw,s)
17.3
1 1+d h k
17.4
Us =
Combining Eq. 17.3 and Eq. 17.4 yields: q=
T p – Tw,s 1+d h k
17.5
as mentioned previously, the heat from the dry side is partly used for vaporising the water on the wet side of the wall, and the rest for increasing the temperature of the working air in the wet channel. however, if the heat from the dry side is used completely in vaporising the water on the wet side of the wall with no sensible heat transfer between the product and working airstreams, the system will achieve its maximum cooling efficiency, as the logarithmic average temperature difference between the two airstreams reaches its highest value. In this case, the working air temperature will remain constant along its pathway, which is equal to the wet side surface temperature (tw = tw,s), but its moisture content will rise along the flow path. For this particular circumstance, the evaporation rate on the wet side surface can be expressed as:
© Woodhead Publishing Limited, 2010
406
Materials for energy efficiency and thermal comfort in buildings
w = q /g =
T p – Tw,s Ê 1 dˆ gÁ + ˜ Ë h k¯
17.6
It can be seen from Eq. 17.6 that both air flow conditions (h, Tp, Tw,s) and material thermal properties (k, d) affect the cooling performance of the system. In terms of air flow, a greater temperature difference between the airstreams in the dry and wet channels would enhance heat/mass transfer in the system, as would increasing the speeds of air flow in both dry and wet channels. In terms of material thermal properties, water retaining capability (Wr), thermal conductivity (k) and wall thickness (d) are potential factors that may impact system performance. Since heat/mass exchange walls are usually thin, with thickness (d) ranging from 0.1 to 0.5 mm, their thermal resistance (d/k) is low, although the value of thermal conductivity (k) may vary widely (between 5 and 300 W/m·°C). Given this, water retaining ability (Wr) is important for cooling effectiveness. Insufficient water retention would reduce the amount of evaporation and so reduce cooling efficiency, while surplus water retention would result in water accumulating on the wet side of the material, which would retard heat/mass transfer. In air conditioning applications, the wet surface temperature, Tw,s, could be taken as the inlet working air wet-bulb temperature (the lowest possible level), which is around 15 °C for the UK climate [7]. The product air temperature, Tp, could be as high as 35 °C. Thus the Tp – Tw,s would be about 20 °C or less, and h is usually less than 20 W/m2·°C for a heat exchanger [8]. The latent heat of water vaporisation, g, could be expressed as: g = 2500 – 2.387Twb
17.7
where Twb is the wet-bulb temperature of the contact surface above the water film. If it was 15 °C, g would be 2464 J/g. Substituting these values into Eq. 17.6 yields, w=
20
dˆ Ê 2464Á 0.05 + ˜ k¯ Ë
=
0.0081 dˆ Ê ÁË 0.05 + k˜¯
17.8
The thickness of the wall, d, is in the range of 0.1 to 0.5 mm, while thermal conductivity, k, takes the weighted average of the k values of the materials and the water, owing to the porous structure. Thus k can be written as [9]: k = rkwater + (1 – r)kmaterials
17.9
where the k value of the water is about 0.6 W/m·°C. For commonly used wall materials, such as metal, fibre, ceramics, zeolite and carbon, k values
© Woodhead Publishing Limited, 2010
Porous materials for direct and indirect evaporative cooling
407
range from 0.3 to 300 W/m·°C, and porosity varies between 20% and 90%, as shown in Tables 17.1 to 17.4. Substituting these values into Eq. 17.9 yields the k value of the watersaturated wall, which is in the range of 0.57 (ceramics with 90% porosity) to 270.06 W/m·°C (metal with 20% porosity). Assuming a wall thickness of 0.5 mm, then the yield value of d/k would be in the range 0.88 ¥ 10–3 to 1.85 ¥ 10–6 m2·°C/W. Substituting this into Eq. 17.8, the evaporation rate w can then be obtained, which is in the range 0.1592–0.16194 g/m2·s, i.e., 0.57312–0.58298 l/m2 · h. If these figures are applied to Eq. 17.6, the heat transfer rate across the wall is then obtained, which in this example would be about 392–399 W/m2. Assuming the void space is completely filled with water, the water retaining volume of a 0.5 mm thick wall would be in the range 0.1–0.45 litre, which is able to support 0.3–1 h of evaporation in an air conditioning application. The above analysis shows that the thermal conductivity and water retaining capability (porosity) of the material have little impact on the magnitude of Table 17.1 Thermal conductivity of selected metals and alloys Metals
Thermal conductivity (W/m·K)
Copper and copper alloys Aluminium and aluminium alloys
115.98–159.25 349.66–400 83.78–86.55 36.35–55.93 29.43–45.01 201.95–226.00 158.6–340.89 107.32–323.70 229 121–222
Copper-zinc-lead brasses Wrought copper Copper-tin-bronze alloys Wrought copper-aluminium alloys Wrought copper-nickel alloys Wrought copper suitable for tube Copper suitable for pipes Wrought high copper alloy Aluminium Aluminium alloys
Table 17.2 Thermal characteristics of selected fibres Fibres
Thermal conductivity (W/m·K)
Wood fibres 0.012–0.654 Latex with cement 0.28–0.52 Methylcellulose with cement 0.32–0.42 Silica fume 0.33–0.36 Methylcellulose + fibre + cement 0.28–0.44 Silica fume + methylcellulose 0.28–0.36 Natural random fibrous 0.02–0.13 materials (Porosity = 10–58%) (Sisal, ramie and jute) Cotton fibre 0.176–0.351 Glass fibre 0.277
© Woodhead Publishing Limited, 2010
Porosity (%) 54.7–63.6 (very high water penetrability) 1.10–2.32(±0.02) 2.07–2.12(±0.02) 2.97–3.14(±0.02) 3.33–3.97(±0.02) 3.14–4.36(±0.02) Porosity = 10–58% 40 2.05–2.3 (±0.02)
408
Materials for energy efficiency and thermal comfort in buildings
Table 17.3 Thermal conductivity of various ceramics Kinds of porous ceramics
Thermal conductivity (W/m · K)
SiC/SiC composites (conventional process) 0.08–15 (porosity = 33.0%) SiC/SiC composites (chemical vapour deposition) 18.5–32.5 (porosity = 33.0 ± 0.6%) SiC/SiC composites (polymer impregnation and pyrolysis) 19–50 (porosity = 32.4 ± 0.4%) Zirconia ceramics (porosity = 0–100%) 0–2.2 Zirconia toughened alumina (a) (porosity = 40%) 11.09 Zirconia toughened alumina (b) (porosity = 22%) 21.67 Zirconia toughened alumina (c) (porosity = 15%) 22.79 3.1 ZrO2 Al2O3 29 Aluminum nitride and polystyrene composites 20–240 (porosity = 0–40)
Table 17.4 Thermal conductivity and porosity of selected carbon fibres and carbon composites Various carbons materials
Thermal conductivity (W/m·K)
Porosity (%)
Carbon–carbon composites Activated carbons Natural graphite + carbon composites Mesophase pitchbased fibres Interplay continuous/spun hybrid carbon composites Carbons fibres (porosity = 2.37–9.31) 3D-Hi-Nicalon type S–CVI composites
55–320 0.2 1–32 300–1100 0.68–2.24
31.4–46.1, 6.3–9.1 80 ≥18 1.94 ± 0.1–29.9±0.5 30–40
175–200 15–108
2.37–9.31 34–40
heat and mass transfer rates, and are therefore not important considerations for material selection. The water retaining capacity of the material is greater than that needed to support the evaporation, so the wet surface of the wall will not dry out. Other criteria relevant to material selection include shape formation/holding ability, durability, compatibility with waterproof coatings, contamination risk and cost. Shape formation/holding ability describes the level of difficulty in shaping a material and whether it holds that shape effectively, and is evaluated by Young’s modulus, in Pascal (Pa). A moderate hardness is preferable, as hard material is difficult to shape, while soft material will not hold a shape. Durability refers to how long the material will work under saturated conditions. Compatibility indicates how the material adapts to other media, for instance substances used for waterproofing the material. This is particularly relevant for
© Woodhead Publishing Limited, 2010
Porous materials for direct and indirect evaporative cooling
409
indirect evaporative cooling, since the material will be wet on one side and dry on the other and so one side needs to be waterproofed to prevent water penetration. The waterproof coating could be made of the same material as the wall, or some other material which is compatible with the wall material. Contamination risks indicate the possibility of bacterial growth under wet operating conditions, and cost is an important factor when determining the type of material to use.
17.3
Comparative analyses of potential materials for evaporative cooling
17.3.1 Metal Traditional metal heat exchangers are made mainly of aluminium, copper and their alloys, which are shaped into an exchanger surface such as a plate or tube. To increase surface capillary force, and thus improve its ability to retain water for evaporative cooling, the surface on one or both sides of the sheet or tube is covered with a porous wick structure [10]. Several porous metal structures, wicked metal, metal foams and wools, will be described in this section. Table 17.1 gives the thermal conductivity of copper, aluminium and their alloys [11, 12]. The wick may be in the form of sintered particles, microscopic holes, meshes, grooves or whiskers, and is attached to the tube or sheet to hold water for evaporation. The porosity of the wick varies widely, from 20% to 90%, depending upon its construction, density and configuration. Fig. 17.7 shows a whiskered tube heat exchanger, which has a large volume of micro-cavities on the external surface of the tube [13]. The density of metal whiskers covering the tube determines the porosity of the tube surface. For water retention, this structure is usually better than making holes or grooves on the tube. Intensive evaporation process
Extremely high surface area
Extremely high porosity
Extremely high cooling power
Metal profile and tube are unified
17.7 Heat exchanging copper tube with micro-structure surface.
© Woodhead Publishing Limited, 2010
410
Materials for energy efficiency and thermal comfort in buildings
In recent years, highly conductive foams based on copper or aluminium have been used to make heat exchangers. These foams have open cell structures that allow heat to be removed from or added to gases or liquids by letting them flow through the cooled or heated foam [14]. Owing to the open porous structure, this type of heat exchanger can contain plenty of water and so allow moisture transfer as well. The foams are produced using different methods, including melts, powders, sputtering and deposition [15]. Each method covers a characteristic range of density, cell size and cell topology, thus resulting in porosity ranging from 30% to 80%. At present, pore sizes ranging from 4.5–0.5 mm at constant porosity of 80% have been achieved. Porosity, shape information and construction expense are related to each other [15]. Figure 17.8 shows some commonly available metal foams [16]. Metal wools are the other type of porous metal used, and are made mainly from copper, aluminium and steel. Porosity varies, based on metal fibre length, fibre diameter and density, and ranges from 30% to 95%. The porosity of one kind of copper wool was found to be 0.95 and the thermal conductivity of this form of copper reduced to 1.0–2.7 W/m·K [17]. Figure 17.9 shows some commonly available metal wools [18]. If any of the above materials are used as the exchanger panel in an indirect evaporation cooling system, one side of the panel has to be waterproofed to prevent penetration of moisture. This can be achieved by attaching a thin solid film of the same material onto the porous metal. Analysing the materials using the method given in Section 17.2 above showed that the thermal conductivity and porosity of any metal structure are both high enough to allow the heat/mass transfer necessary for air conditioning applications. This means that any of the metal types described is suitable for use as the exchanger plate, and the thermal properties of the metals are the least important factors in material selection.
17.8 Metal foams.
© Woodhead Publishing Limited, 2010
Porous materials for direct and indirect evaporative cooling
411
17.9 Metal wools.
17.10 Fibre structure of hardwood.
In terms of hardness, copper and aluminium have Young’s moduli ranging from 70 to 140 GPa, giving them suitable shaping and shape-holding properties for the exchanger plate [19], [20]. Copper and aluminium are also durable and compatible with solid metal of the same material. In terms of risk of bacterial growth, metal plates with wick (sintered, meshed, grooved or whiskered) are better than foams and wools, as the pores on the wicked plates are exposed rather than concealed, facilitating cleaning or other hygiene treatments of the surface. In terms of cost, aluminium is much cheaper than copper [21].
17.3.2 Fibre Fibrous materials, such as paperboard, cloth, wood or glass fibre, and others, have relatively high penetrability and lower thermal conductivity and hardness. Figure 17.10 shows the structure of a hardwood fibre, and Table 17.2 presents the thermal conductivity of various fibrous materials [22]–[25]. It can be seen that the fibres have much lower thermal conductivity than metals, ranging from 0.01 to 0.3 W/m·K [26]. Solid fibres have lower thermal conductivity than porous ones [25]. Table 17.2 also gives the porosity of a number of commonly used fibre materials. Wooden fibre, natural random fibre and
© Woodhead Publishing Limited, 2010
412
Materials for energy efficiency and thermal comfort in buildings
glass fibre have the same level of porosity, ranging from 10 to 60%, while the others have a much lower level, ranging from 1 to 5%. The effective thermal conductivity of a fibrous material increases with the fibre length, and approaches a stable level when the fibre length is sufficiently long. The effective thermal conductivity decreases as porosity increases [27]. Although the thermal conductivities of fibres are much lower than those of metals, an analysis using the method given in Section 17.2 indicated that the fibres are still able to provide a heat transfer rate of 392–399 W/m2, which is sufficient for air conditioning applications. Fibre porosities are also sufficient to retain the water needed for moisture transfer. It would be preferable to choose a fibre with low porosity, as this kind of fibre has lower water retaining capacity, which would enhance sensible heat transfer. Most of the fibres presented in Table 17.2 are suitable for use as heat exchanger material, except for wood and cotton. In terms of hardness, most fibre materials are not strong enough to be used as exchanger plates. However, flax or wooden fibres are the exception, with Young’s moduli as high as 70 to 110 GPa in the longitudinal direction. The lifespan of most fibre exchangers is short, as the material is easily deformed or damaged when soaked with water, except for flax or wood fibre. Fibre is compatible with polyethylene, which is used to waterproof one side of the fibre to prevent water penetration [28]. Wet fibre surfaces are readily contaminated by bacteria, which is not good for evaporative cooling applications. However, fibres are extremely cheap [28], and so frequent replacement is affordable, potentially overcoming the difficulties of short lifespan and contamination risk.
17.3.3 Ceramics Porous ceramics have potential for use in evaporative cooling due to their strength, high thermal conductivity, waterproof nature and durability. Porous solids, such as extruded monoliths with parallel channels and thin walls, and made of various oxide and non-oxide ceramics, ceramic foams and metal structure, can perform both moisture retaining and heat exchanging activities. Figure 17.11 presents several foam-structured porous ceramics made by IKTS [29]. The thermal conductivity of porous ceramics depends upon composition, pore size and distribution, porosity and the manufacturing process. It varies from 0.1 to 240 W/m·K. Generally the thermal conductivity decreases as porosity increases [30]. Table 17.3 shows the thermal conductivity of a range of different ceramics [29], [31]–[33]. The water retaining capacity of ceramics increases with increasing porosity and pore size. One way to make porous ceramics is by mixing ground vermiculite and allophone at 600–800 °C [34].
© Woodhead Publishing Limited, 2010
Porous materials for direct and indirect evaporative cooling
413
17.11 Ceramic structure overview.
The thermal conductivities of ceramics are higher than those of fibres, but lower than those of metals. This is sufficient for the heat/mass transfer needed in an air conditioning application. The porosities of ceramics are also sufficient to retain the water needed for moisture transfer. A ceramic with low porosity is preferable, because it has lower water retaining capacity thus enhancing sensible heat transfer. Aluminium nitride and polystyrene composites can be made at low porosity levels, such as 1% or below, and therefore may be suitable for use in this application. A porous ceramic may be combined with a thin film made of the same material to prevent penetration of moisture when being used in indirect evaporation systems. In terms of hardness, most porous ceramics have Young’s moduli ranging from 50 to 400 GPa [35]–[38], making them suitable for use as exchanger plates. Porous ceramics are durable in wet conditions, and are compatible with solid film of the same material. Their porous structure is likely to be susceptible to bacterial growth when wet, and as the pores are concealed inside the structure, cleaning is difficult. Ceramics cost about twice as much as metal heat exchanger plates [39].
17.3.4 Zeolites Zeolites can be classified as natural and synthetic zeolites. Natural zeolites are aluminosilicate minerals. They occur in nature and are mined rather than synthesised. Zeolites have a very open crystalline lattice that allows molecules like water vapour to be held inside the crystal itself like an object in a cage. Particular atoms of an aluminosilicate determine the size of the openings between the ‘bars’ of the cage, which in turn governs the maximum size of the molecule that can be adsorbed into the structure. Synthetic zeolites, also called molecular sieves, are crystalline aluminosilicates manufactured in a thermal process. Controlling the temperature of the process and the composition of the ingredient materials allows close control of the structure and surface characteristics of the adsorbent. At a somewhat higher cost, this provides a much more uniform product than naturally occurring zeolites. Crystalline zeolites can be used for a wide variety of purposes including static and dynamic drying, ion exchange, and selective separations involving
© Woodhead Publishing Limited, 2010
414
Materials for energy efficiency and thermal comfort in buildings
gases and liquids. Industrial applications of zeolites are primarily as Linde Molecular Sieves (LMS) and Davison Microtraps, due to availability in quantity and cost. Synthetic zeolites are attractive for drying and separation owing to their affinity for water and other small diameter molecules, and also their ability to reject large diameter molecules [40]. The thermal conductivity of LMS is around 0.59 W/m·K, which is much smaller than that of metals or porous ceramics [40]. However, the figure is still high enough to provide adequate heat transfer for air conditioning applications. Linde Molecular Sieves have a high sorption capacity at low water vapour concentrations, and maintain their high sorption capacity at elevated relative humidity, which is in direct contrast to silica gel and activated alumina [41]. They have a porosity of 40–80%, but the absorption capacity is even higher due to water affinity characteristics. The water retaining potential is good enough to make LMS suitable for the moisture transfer requirements of air conditioning applications. Zeolite material used in the exchanging wall can be coated with polyethylene or wax [42, 43] on one side to prevent moisture penetration when being used in indirect evaporation systems. In terms of hardness, most zeolites are adequately strong for use as exchanger plates, having Young’s moduli ranging from 1 to 20 GPa [44]. Since the pores are internal, the zeolite structure is susceptible to bacterial growth when wet. In terms of cost, they are more expensive than ceramics [39].
17.3.5 Carbon Carbon fibres are important as reinforcement in composite materials because of their low density, high strength (up to 7 GPa) and tensile modulus up to 600 GPa. Carbon fibre is also useful in a wide variety of products due to its high electrical and thermal conductivity [45]. Activated carbons are often used for desiccants, carbon–carbon composites are commonly used in aerospace applications, and mesophase pitch-based carbon fibres with high preferred orientation have low density and high thermal conductivity (k), with a k value at room temperature up to 1120 W/m·°C. Figure 17.12 shows three types of carbon fibre structure [46–48]. Activated carbons have very low thermal conductivity (0.2 W/m·K), resulting in severe thermal limitations due to low overall adsorption and desorption kinetics as well as secondary reaction products or hazards in industrial applications. The in situ activation of various precursors within a consolidated expanded natural graphite matrix results in composites with high thermal conductivities (from 1 to 32 W/m·°C) and high effective adsorbent levels (80 wt%) [45]. The type of carbon fibres in the composites plays an
© Woodhead Publishing Limited, 2010
Porous materials for direct and indirect evaporative cooling
(a)
(b)
415
(c)
17.12 Three types of carbon fibre structures (a) laminated short fibre felt; (b) laminated carbon cloth felt; (c) needle picked long fibre felt.
important role in thermal conduction behaviour and the highly graphitic flat-layered structured fibres conduct in a direction parallel to the fibre axis [46]. Table 17.4 presents the thermal conductivity and porosity of selected carbon fibre materials [47–55]. Analysis using the method given in Section 17.2 indicates that the thermal properties of carbon materials are good enough to transfer both sensible and latent heat in air conditioning applications. A carbon material with low porosity would be preferable, as the resultant lower water retaining capacity would enable enhanced sensible heat transfer. Carbon fibres or mesophase pitch-based fibres could be made at low porosity levels, such as 1% or below, and therefore may be suitable for use in this application. Carbon fibres used in a heat exchanging wall can also be coated with polyethylene or wax on one side to prevent moisture penetration when being used in indirect evaporation systems [56, 57]. In terms of stiffness, carbon fibres are strong enough to be formed into heat/mass transfer elements, having Young’s moduli ranging from 1 to 220 GPa [44]. Since the pores are internal, a carbon fibre structure is likely to be susceptible to bacterial growth when wet for a long time. In terms of cost, carbon fibre materials have similar prices to metals [39].
17.3.6 Comparing the materials Table 17.5 summarises the performance of the materials described above in terms of thermal conductivity, porosity, hardness, compatibility with coating materials, contamination risk and cost. All the materials described have thermal properties suitable for the heat/ mass transfer required in air conditioning applications (up to 390 W/m2), so it is unnecessary to consider the impact of thermal conductivity and porosity on thermal performance when selecting one of these materials for a heat/mass exchanger. Thus the most important factors to be considered are hardness, compatibility with coating materials, contamination risk and cost. Metal and ceramics are better choices for hardness (shaping and shape-retaining ability), followed by zeolite, carbon and fibre. All the selected materials are compatible
© Woodhead Publishing Limited, 2010
416
© Woodhead Publishing Limited, 2010
Index Material type
Thermal Porosity (%) Hardness Compatibility Contamination conductivity (shaping ability) with coating risk (W/m·K)
Metal High 20–90 High Fibre Low 1–60 Low Ceramic Variable 1–80 High Zeolite Low 40–80 Medium Carbon Variable Variable Medium
Compatible with the solid metal Compatible to polyethylene Compatible with the solid metal Compatible to polyethylene or wax Compatible to polyethylene or wax
Cost (£) per sheet [39] 100 ¥ 100 ¥ 0.5 (mm ¥ mm ¥ mm)
Low (sintered metal) High
30–100
High
150–250
High
150–250
High
30–80
<5
Materials for energy efficiency and thermal comfort in buildings
Table 17.5 Summary of the properties of selected material types
Porous materials for direct and indirect evaporative cooling
417
with a specific coating and therefore they have comparable performances in this respect. For contamination considerations, wicked (sintered, meshed, grooved or whiskered) metal plate is the best material, while the others are subject to contamination. From the cost point of view, fibre is the cheapest material, followed by metal and carbon. Ceramics and zeolite are the most expensive materials and are therefore not cost effective. In summary, for a durable and healthy air conditioning system, wicked metal plates (copper or aluminium) are the preferable option for heat/mass transfer materials. They are cheaper than ceramics and zeolites, about the same price as carbons, but more expensive than fibres. This price level is acceptable when the other benefits of metals are taken into account.
17.4
Potential applications of porous materials in buildings
17.4.1 Evaporative cooling The porous materials discussed above could be used in evaporative cooling in different ways. The most common application is in heat and mass exchangers. Some types of porous materials, including metal wools/foams and ceramics, could be used in the façades of buildings to allow passive or active cooling of the internal spaces. For the direct cooling façade pattern shown in Fig. 17.13, warm air would be drawn from outside, pass across the wet surface
17.13 A façade-based evaporative cooling system.
© Woodhead Publishing Limited, 2010
418
Materials for energy efficiency and thermal comfort in buildings
of the façade, where heat and moisture exchange would occur, and finally be delivered into the building at a cooler temperature. To avoid adding moisture to the air, a façade made of porous materials could also be designed as an indirect cooling structure, which would allow air to be cooled without adding moisture. A diagram of an indirect cooling module for a façade is shown in Fig. 17.14. It is based on integrating a porous media (cast or sintered ceramic, metal foam) water container and an array of finned heat pipes. This type of system employs air and water as the working fluids, and is suitable for use in different types of buildings, including high-rise buildings, housing estates or office blocks. Each module is a curtain wall unit made up of three layers: an outer weatherproof layer, a middle-layer divided into two parts (with an upper cavity containing a slim water-containing porous panel and surrounding space for air movement, and a number of finned heat pipes arrayed in a row, with their upper non-finned parts inserted into the water container, and the
Porous media water container Evaporation Heat pipes with fins
Supply air
Outdoor air
Return air
17.14 A module façade for indirect evaporative cooling.
© Woodhead Publishing Limited, 2010
Porous materials for direct and indirect evaporative cooling
419
lower finned parts extending to a separate cavity below), and an inner layer made of water-resistant internal wall panel. All these modules could be integrated into a building façade, and share a common water tank situated at a convenient point in the building. The water tank could supply water to all the containers using a valve for control, and allow the over-charged water to be collected at certain intervals by the use of a pump fitted on the return line. A schematc of the module-integrated façade in a building is shown in Fig. 17.15. In the module, outdoor air enters the outer cavity of the sandwich wall through air grilles on the lower part of the outer layer. The air then flows over the surface of a porous panel, which forms part of the mid-layer of the wall. The air movement aids water evaporation off the surface of the panel, and channels the water-laden air out into the atmosphere. However, the main cause of water evaporation is heat loss from the pipes contained in the upper part of the module. This heat loss enables the pipes to transfer heat energy away from the inner cavity of the sandwich wall, in turn drawing room air into the cavity to be cooled. The cooled air can then be delivered to the room space using a mini fan, thus creating a cooling effect in the building. The layout in Fig. 17.15 allows the lower part of the inner cavity of the sandwich wall to act as a fan-coil unit. Use of such modules in walls could enable a passive evaporative cooling device to be integrated into building construction, allowing indirect evaporative cooling to be utilised in buildings on a large scale.
17.4.2 Other applications Porous materials have other uses in buildings apart from evaporative cooling. Examples of these applications are given below. Water tank
Return to the tank
17.15 Module façades in building application – an indirect evaporative cooling system.
© Woodhead Publishing Limited, 2010
420
Materials for energy efficiency and thermal comfort in buildings
Cellulose fibre Cellulose fibre could be used for making air-to-air heat and mass exchangers to recover energy from outgoing air. A diagram of a recently developed cellulose fibre heat and mass exchanger is shown in Fig. 17.16. The device exchanges heat and moisture between two airstreams through adjacent fibre membranes. The membranes are separated by guides that run the length of one sheet and the width of the next sheet. This allows the development of an almost infinite number of energy exchange microenvironments between the two airstreams, and energy (enthalpy) exchange efficiencies range from 70% to 80% [58]. Two coating methods, adsorbent (CaCl) finishing and absorbent (LiCl) filming, were applied to the surface of the cellulose fibre to further enhance its energy (enthalpy) efficiency. It was found that both methods have potential to improve energy exchange efficiency, particularly moisture transfer efficiency of the exchanger. This is because coating increased the moisture infiltration coefficients of the membrane, and also the convective mass transfer coefficients on both sides of the membrane. For the given exchanger geometries and operating conditions, the absorbent filming had the most significant impact on exchanger efficiency, with its enthalpy efficiency being about 15.9% higher than the adsorbent finishing, and 25.6% higher
17.16 A cellulose fibre air-to-air heat and mass exchanger.
© Woodhead Publishing Limited, 2010
Porous materials for direct and indirect evaporative cooling
421
than the uncoated fibre. These two coating methods significantly affect the moisture exchange efficiency of cellulose fibres. Absorbent filming can achieve 84.5% moisture exchange efficiency, which is 38.7% and 28.1% higher than those of uncoated fibres and adsorbent finishing, respectively. With the adsorbent finishing and absorbent filming, the sensible heat transfer efficiency was increased by 5.9% and 9.0% respectively, due to the increased thermal conductivity of the membrane caused by the coatings [59]. Porous metals Porous metals are known to be useful in heat exchangers for air conditioning applications in buildings. An interesting application for porous metals is in heat pipe technology, which usually employs wicked metal tubes or plates, with varied wick structures (including sintered particles, microscopic holes, meshes, grooves or whiskers). These structures enable the working fluid to return easily from the condensation section to the evaporation section under the action of the capillary force generated by the wicks. The wicked heat pipe and its working principles are shown schematically in Fig. 17.17. Ceramics Ceramics are commonly used to make various building components, such as walls, roofs, baths, basins and others, which are characteristically lightweight and have a long lifespan. Ceramics are also used in sound attenuation apparatus as the numerous pores within the ceramics can absorb sound effectively. An interesting application of ceramics is the perspiration wall, which can lead to natural ventilation and dynamic thermal insulation.
Heat pipe Heat input
Heat output
Evaporation section
Adiabatic section
Condensation section
Metal wick
17.17 A heat pipe with metal wick.
© Woodhead Publishing Limited, 2010
422
Materials for energy efficiency and thermal comfort in buildings
Zeolites In air conditioning applications in buildings, zeolites are commonly used as adsorbents which dehumidify and humidify air. Carbons In buildings, activated carbons are most frequently used for adsorption of gases other than water vapour because they have a greater affinity for the nonpolar molecules typical of organic solvents. Like other adsorbents, carbons have a larger internal surface and especially larger capillaries. This capillary volume gives them a high capacity to adsorb water vapour at relative humidities of 45 to 100%.
17.5
Conclusions
There are five major types of materials used in heat and mass transfer applications: metal, cellulose fibre, zeolite, ceramic and carbon. Each type of material has an optimum configuration when being used as a heat/mass transfer medium in evaporative cooling systems. Metals used in these systems are in the form of wicked (sintered, meshed, grooved or whiskered) copper or aluminium sheets; fibres are wooden or flax fibres with low porosity; ceramics have a metal-based structure with low porosity; and zeolite and carbon materials tend to have low porosity and high thermal conductivity. The heat and mass transfer characteristics of these materials when used in heat/mass exchangers for air conditioning applications were investigated. Heat transfer rates were found to be in the range of 392–399 W/m2, and moisture evaporation rates between 0.57 and 0.58 l/m2·h. These rates are relatively low, indicating that the thermal properties of the selected materials, i.e., thermal conductivity and porosity, have very little impact on the process. Thus these two parameters play minor roles when selecting heat and mass exchanging materials. Instead, shape formation/holding ability, durability, compatibility with coating materials, contamination risk and cost become more important concerns. As indirect evaporative cooling requires product air to be cooled without adding moisture, a waterproof coating is needed on one side of the exchanging sheet. Each of the materials are compatible with specific coatings and therefore there were no distinct differences in terms of coating compatibility. The material used for evaporative cooling needs to be formed into defined shapes that are durable, and metal and ceramic materials are better than zeolite, carbon and fibre in this regard. As the wet channels are always soaked with water, there is a high risk of bacterial growth within the porous structure, particularly interior pores. To
© Woodhead Publishing Limited, 2010
Porous materials for direct and indirect evaporative cooling
423
avoid this, an exposed pore structure is preferable, permitting frequent cleaning and sterilization of the material. A wicked metal (copper or aluminium) is the most suitable material in this regard. In terms of cost, fibre is the cheapest of the five materials. Metals and carbons cost more than fibres but less than ceramics and zeolites. In summary, wicked metals (copper or aluminium) are the most suitable materials for evaporative cooling applications. Wicked aluminium sheet is much cheaper than copper sheet with the same structure, and therefore preferred. Porous materials also have a range of other uses in buildings and building services, including as dehumidifiers, humidifiers, in structural applications and for soundproofing.
17.6
References
1. http://www.idalex.com/technology/how_it_works_-_engineering_perspective.htm 2. Lertsatitthanakorn C., Rerngwongwitaya S. and Soponronnarit S., Field experiments and economic evaluation of an evaporative cooling system in a silkworm rearing house, Biosystems Engineering, 93(2) (2006) 213–219. 3. Stoitchkov N. J. and Dimitrov G. I., Effectiveness of crossflow plate heat exchanger for indirect evaporative cooling, International Journal of Refrigeration, 21(6) (1998) 463–471. 4. Maisotsenko V. et al., Method and plate apparatus for dew point evaporative cooler, United States Patent 6,581,402, June 24, 2003. 5. Zhao X., Li J. and Riffat S. B., Numerical study of a novel counter-flow heat and mass exchanger for dew point cooling system, Applied Thermal Engineering, 28 (2008) 1942–1951. 6. Zhao X., Liu S. and Riffat S. B., Comparative study of the heat and mass exchanging materials for the indirect evaporative cooling systems, Building and Environment, 43 (2008) 1902–1911. 7. CIBSE Guide A, Environmental Design, Page Bros. (Norwich) Ltd., Norwich, 2001; 2–6. 8. Heat Transfer, China Building Industry Press, Beijing, China, 1993; 297–298. 9. Parrott J.E. and Stuckes A. D., Thermal Conductivity of Solids, Pion Limited, London, 1975, 201. 10. Tadrist L., Miscevic M., Rahli O. and Topin F., About the use of fibrous materials in compact heat exchangers, Experimental Thermal and Fluid Science, 28 (2004) 193–199. 11. Schweitze P. A., Metallic Materials, Physical, Mechanical and Corrosion Properties, Marcel Dekker, Boca Raton, FL, 2003. 12. Welty J. R., Wicks C. E., Wilson R. E. and Rorrer G. L., Fundamentals of Momentum, Heat, and Mass Transfer, John Wiley & Sons, New York, 2000, 723–724. 13. Schulz A., Akapiev G. N., Shirkova V. V., Rösler H. and Dmitriev S. N., A new method of fabrication of heat transfer surfaces with micro-structured profile, Nuclear Instruments and Methods in Physics Research B, 236 (2005) 254–258. 14. Banhart J., Manufacturing, characterisation and application of cellular metals and metal foams, Progress in Materials Science, 46 (2001) 559–632. 15. Clyne T. W. and Simancik F., Metal Matrix Composites and Metallic Foams, EUROMAT, Volume 5, Weinheim, New York, 2000. © Woodhead Publishing Limited, 2010
424
Materials for energy efficiency and thermal comfort in buildings
16. http://www.ifam-dd.fraunhofer.de/fhg/ifam_dd/EN/gebiete/schaum/index.jsp 17. Lacroix C., Ramany Bala P. and Feidt M., Evaluation of the effective thermal conductivity in metallic porous media submitted to incident radiative flux in transient conditions, Energy Conversion & Management, 40 (1999) 1775–1781. 18. http://www.briwax-online.com/GMT.html 19. Pelletier H., Predictive model to estimate the stress–strain curves of bulk metals using nanoindentation, Tribology International, 39 (2006) 593–606. 20. Piggott, M., Load Bearing Fibre Composites, 2nd edn, Kluwer Academic Publishers, London, 2002. 21. RS Catalogue Data 5, Mechanical, UK, 2004, 5 (150) – 5 (170). 22. Sevostianov I. and Kachanov M., Connection between elastic moduli and thermal conductivities of anisotropic short fiber reinforced thermoplastics: theory and experimental verification, Materials Science and Engineering, A360 (2003) 339– 344. 23. Fan L., Hu Y., Tian T. and Yu Z., The prediction of effective thermal conductivities perpendicular to the fibres of wood using a fractal model and an improved transient measurement technique, International Journal of Heat and Mass Transfer, 49 (2006) 4116–4123. 24. Fu X. and Chung D., Effects of silica fume, latex, methylcellulose, and carbon fibers on the thermal conductivity and specific heat of cement paste, Cement and Concrete Research, 27(12) (1997) 1799–1804. 25. Thunman H. and Leckner B., Thermal conductivity of wood – models for different stages of combustion, Biomass and Bioenergy, 23 (2002) 47–54. 26. Gaier J., Yoder Vandenberg Y., Berkebile S., Stueben H. and Balagadde F., The electrical and thermal conductivity of woven pristine and intercalated graphite fiber–polymer composites, Carbon, 41 (2003) 2187–2193. 27. Wang M., he J., Yu J. and Pan N., Lattice Boltzmann modelling of effective thermal conductivity for fibrous materials, International Journal of Thermal Science, 46(9) (2007) 848–855. 28. Coolerado, Coolerado HMX (Heat and Mass Exchanger) Brochure, Coolerado Corporation, Arvada, Co, USA, 2006. 29. Fend T., Hoffschmidt B., Pitz-Paal R., Reutter O. and Rietbrock P., Porous materials as open volumetric solar receivers: experimental determination of thermophysical and heat transfer properties, Energy, 29 (2004) 823–833. 30. Nait-Ali B., Haberko K., Vesteghem H., Abse J. and Smith D.S., Thermal conductivity of highly porous zirconia, Journal of the European Ceramic Society, 26 (2006) 3567–3574. 31. Taguchi T., Igawa N., Yamada R. and Jitsukawa S., Effect of thick SiC interphase layers on microstructure, mechanical and thermal properties of reaction-bonded SiC/ SiC composites, Journal of Physics and Chemistry of Solids, 66 (2005) 576–580. 32. Pezzotti G., Kamada I. and Miki S., Thermal conductivity of AlN/polystyrene interpenetrating networks, Journal of the European Ceramic Society, 20 (2000) 1197–1203. 33. Itatani K., Tanaka T. and Davies I. J., Thermal properties of silicon carbide composites fabricated with chopped Tyranno® Si- Al- C fibres, Journal of the European Ceramic Society, 26 (2006) 703–710. 34. Okada K., Matsui S., Isobe T., Kameshima Y. and Nakajima A., Water-retention properties of porous ceramics prepared from mixtures of allophone and vermiculite for materials to counteract heat island effects, Ceramics International, 10 (2006) 1–6.
© Woodhead Publishing Limited, 2010
Porous materials for direct and indirect evaporative cooling
425
35. Pabst W., Gregorová E. and Tichá G., Elasticity of porous ceramics – a critical study of modulus–porosity relations, Journal of the European Ceramic Society, 26 (2006) 1085–1097. 36. Burkes D., Gottoli G. and Moore J. J., Mechanical properties of porous combustion synthesized Ni3Ti-TiCx composites, Composites Science and Technology, 66 (2006) 1931–1940. 37. Jeong H. and Hsu D., Quantitative estimation of material properties of porous ceramics by means of composite micromechanics and ultrasonic velocity, NDT&E International, 29(2) (1996) 95–101. 38. Krauß G., Kubler J. and Trentini E., Preparation and properties of pressureless infiltrated SiC and A1N particulate reinforced metal ceramic composities based on bronze and iron alloys, Materials Science and Engineering, A337 (2002) 315–322. 39. http://www.goodfellow.com/scripts/web.wl?MGWLPN=MNT&PROG=SEARTOW &LAN=A&HEAD=ZZCAAAAC&SPAGE=C%204l 40. Hersh C. K., Molecular Sieves, New York, Reinhold Publishing corporation, Chapman & Hall, Ltd, London, 1961. 41. Jeong J. and Mumma S. A., Practical thermal performance correlations for molecular sieve and silica gel loaded enthalpy wheels, Applied Thermal Engineering, 25 (2005) 719–740. 42. http://www.patentstorm.us/patents/5846696-description.html 43. http://www.patentstorm.us/patents/6180708-description.html 44. Metin D., Tihminlioglu F., Balköse D. and Ülkü S., The effect of interfacial interactions on the mechanical properties of polypropylene/natural zeolite composites, Composites: Part A, 35 (2004) 23–32. 45. Py X., Daguerre E. and Menard D., Composites of expanded natural graphite and in situ prepared activated carbons, Carbon, 40 (2002) 1255–1265. 46. Manocha L. M., Warrier A., Manocha S., Sathiyamoorthy D. and Banerjee S., Thermophysical properties of densified pitch based carbon/carbon materials – I. Unidirectional composites, Carbon, 44 (2006) 480–487. 47. Liu Z., Zhang G., Li H., Sun J. and Ren M., Al infiltrated C–C hybrid composites, Materials and Design, 26 (2005) 83–87. 48. Ma Z., Shi J., Song Y., Guo Q., Shai G. and Liu L., Carbon with high thermal conductivity, prepared from ribbon-shaped mesophase pitch-based fibers, Carbon, 44 (2006) 1298–1301. 49. Yamada R., Igawa N. and Taguchi T., Thermal diffusivity/conductivity of Tyranno SA fiber- and Hi-Nicalon Type S fiber-reinforced 3-D SiC/SiC composites, Journal of Nuclear Materials, 329–333 (2004) 497–501. 50. Frusteri F., Leonardi V., Vasta S. and Restuccia G., Thermal conductivity measurement of a PCM based storage system containing carbon fibers, Applied Thermal Engineering, 25 (2005) 1623–1633. 51. Sivakumar R., Guo S., Nishimura T. and Kagawa Y., Thermal conductivity in multiwall carbon nanotube/silica-based nanocomposites, Scripta Materialia, 56 (2007) 265–268. 52. Wanner A., Elastic modulus measurements of extremely porous ceramic materials by ultrasonic phase spectroscopy, Materials Science and Engineering, A248 (1998) 35–43. 53. Wang Y., Tan S. and Jiang D., The effect of porous carbon preform and the infiltration process on the properties of reaction-formed SiC, Carbon, 42 (2004) 1833–1839. 54. Wang X. L., Zhang H. M., Zhang J. L., Xu H. F., Tian Z. Q., Chen J., Zhong H.
© Woodhead Publishing Limited, 2010
426
55.
56. 57. 58. 59.
Materials for energy efficiency and thermal comfort in buildings X., Liang Y. M. and Yi B. L., Micro-porous layer with composite carbon black for PEM fuel cells, Electrochimica Acta, 51 (2006) 4909–4915. Straatman A. G., Gallego N. C., Thompson B. E. and Hangan H., Thermal characterization of porous carbon foam – convection in parallel flow, International Journal of Heat and Mass Transfer, 49 (2006) 1991–1998. http://www.ncbi.nlm.nih.gov/sites/entrez?cmd=Retrieve&db=PubMed&lis t_uids=11199307&dopt=Abstract http://www.patentstorm.us/patents/5539035-description.html Catalogue data of the fibre heat and mass exchanger, manual, Hangzhou ISAW Technology Corporation, 310018, China, 2005. Liu S., Riffat S., Zhao X. and Yuan Y., Impact of adsorbent finishing and absorbent filming on energy exchange efficiency of an air-to-air cellulose fibre heat and mass exchanger, Building and Environment, 44 (2009) 1803–1809.
17.7 h k q r T U s w d h g DTm
Appendix: Nomenclature heat convective coefficient, W/m2; thermal conductivity of the heat transfer wall, W/m · °C; heat flux across 1 m2 of heat transfer area, W/m2; porosity of the wall material; temperature, °C; the overall heat transfer coefficient from dry air flow to the opposite wet wall surface, W·m2, °C; water evaporation rate on the wet surface of the wall, kg/s; thickness of the heat transfer wall, m; cooling efficiency of the evaporative cooling system; latent heat of water evaporation, J/kg; Logarithmic average temperature difference between the two airstreams, °C
Subscript m max min p s w wb 1 2
mean maximum minimum product air surface of the heat transfer wall working air wet bulb inlet outlet
© Woodhead Publishing Limited, 2010
18
Prefabricated building units and modern methods of construction (MMC)
M. M a p s t o n, MMConsult and one42morrow, UK and C. W e s t b r o o k, Mtech Consult Ltd, UK
Abstract: This chapter identifies what constitutes prefabricated buildings and offsite construction, and provides an overview of both old and new systems that are emerging under the banner of modern methods of construction (MMC). It hypothesises that the construction industry has been labelled as being reluctant to change, due in part to a ‘materials led’ approach to building design and delivery; and how government legislation is forcing change engendering a ‘building design led’ culture which seeks to satisfy future building needs and assure sustainability. It suggests that knowledge sharing and partnering are prerequisites for providing swift and effective sustainable design advancement by maximising the use and skills of industry experts across many previously unrelated fields. Key words: offsite, modern methods of construction (MMC), reluctant to change, ‘materials led’, government legislation, sustainability, knowledge sharing, partnering, sustainable design.
18.1
Materials led building design
Buildings and shelters have evolved using readily available, locally sourced materials such as stone, timber, clay, etc. Use of these natural materials as fundamental building elements has developed empirically over time, increasing in skill and complexity, giving rise to ‘materials led’ rather than ‘building design led’ advancement. This approach to building has left a legacy, where the construction industry has been criticised as ‘reluctant to change’ and historically tied by robust technologies. However, with global needs pressing governments to impose ecologically challenging codes and guidelines, the construction industry is being forced by legislation to change; reluctance can no longer be a barrier to that change. The construction industry has a major role to play in delivering an environmentally sustainable future by providing responsible building design. Driven by legislation, this is forcing the design of new materials to fulfil specific functions. As a result buildings (or parts of buildings) are increasingly becoming ‘building design led’ rather than ‘materials led’. Sustainable delivery throughout the life cycle of the building is as much about quality, maintenance, reliability and running costs as it is about 427 © Woodhead Publishing Limited, 2010
428
Materials for energy efficiency and thermal comfort in buildings
designing with the right materials. It is little use maximising material choice and detail design if poor construction techniques or interfacing ruins the design integrity at the very beginning of its life cycle. Offsite construction principles, often referred to as ‘modern methods of construction’ (MMC), enable the designed building, panel or component to be constructed without compromise, providing an environment where repeatable performance, minimal waste and high levels of quality can be assured. This enables buildings to be designed holistically, without needing to ‘dumb down’ the detailing to suit the available skill base, so promoting the design and development of materials and systems which rely upon accuracy and control during construction, to deliver the intended design life and energy map for the building. Whether referred to as offsite, prefabrication or modern methods of construction, generically this provides an environment in which a ‘building led design’ approach can be exploited fully. The factory environment is also predisposed to look beyond the horizon of the immediate building project to consider standardisation of the processes, methods, materials and design.
18.2
Offsite construction
Mtech Consult has developed the following definition based on the BuildOffsite Glossary of Terms (2006): Offsite Construction includes all those elements of construction that involve the pre-assembly (joining together or prefabrication) of a number of construction components, which would otherwise be traditionally incorporated in the works as separate components. There are many good reasons to manufacture a building in a factory rather than making it on site: ∑ Reduced preliminaries due to shorter time on-site. ∑ Reduced project management costs – manufacturer will supplement these skills with directly employed project managers. ∑ Reduced design/professional fees – a large proportion is absorbed into manufacturers’ overheads. ∑ Reduced programme times leading to earlier return on capital employed. ∑ Reduced defects and rework due to high first-time quality. ∑ Reduced waste on-site. ∑ Reduced weather dependency. ∑ Provide controlled procurement strategies. ∑ Reduced reliance on transient labour.
© Woodhead Publishing Limited, 2010
Prefabricated building units and modern methods
∑ ∑
429
Better working environment. Health and safety.
These principal benefits drive the wish to prefabricate buildings and elements of buildings in factories. The extent to which people can benefit from these principles and hence the extent to which prefabrication or Offsite is applicable depends on three basic factors: the physical design of the building, the preferred local methods of working and, most relevant to this book, the materials that are used. It is much easier to create an offsite prefabricated box element of a building in a factory if you make that box from timber or steel than it is if you make it from masonry or stone. Prefabrication and industrialisation of construction methods have been available for some time. From the Crystal Palace or hospitals in the Crimean War, right back to traditional oak frame buildings, ‘offsite’ has long been a small but successful part of the construction industry. In the past, prefabrication has been used periodically to satisfy short-term needs where solutions were required quickly and in bulk, but after the need passed there was generally a return to onsite techniques. After the Second World War, prefabricated buildings were used to respond successfully to the UK’s need for rapid replacement of housing stock at a time of acute materials, labour and site-based skills shortages. Later, fully finished classroom units were manufactured in response to the upturn in educational needs in the 1960s. Furthermore, the 1960s witnessed the development of industrialised high-rise buildings using pre-cast concrete structural elements. This specific building technique was associated with some dramatic failures and has stigmatised developments in the offsite sector. Recently, various organisations in the UK have started to evaluate and develop new construction methods that involve an increasing amount of work being undertaken offsite and incorporating a high level of innovation. Modern offsite technology distinguishes itself from the ‘prefabrication’ label by utilising modern materials, employing robust quality control systems, testing and evaluating products through managed R&D programmes and demonstrating durability and regulatory compliance verified by third party endorsements such as the British Board of Agrément (BBA) approvals or BRE certification. In recent years the measure of ‘benefits’ perceived as being gained from offsite methods has focused primarily on cost savings. Traditional methods of cost comparison are deeply embedded in the existing culture of the construction industry. They are based on initial purchase cost rather than whole life costs or best value procurement and tend to put offsite at a disadvantage. To measure the real cost through the life of a building, it is essential to consider the direct and indirect benefits of using offsite solutions.
© Woodhead Publishing Limited, 2010
430
Materials for energy efficiency and thermal comfort in buildings
Due to a shortage of skilled workers in onsite construction, UK labour costs are likely to rise in future at rates higher than the average for manufacturing. In recent years the cost of all construction in Europe will have remained lower than might otherwise have been the case due to the influx of cheaper European labour. As this influence reduces and the labour cost proportion of construction costs increases, the balance of cost competitiveness will swing in favour of offsite. Offsite construction can reduce the amount of waste generated onsite from between 40% for simple panelised systems, to 90% for more complete modular building (Wrap, 2007). This waste reduction is not just a shift of waste from site to factory because in lean, offsite manufacturing processes the waste generated and sent to landfill is less than 1% of the total weight of material used. This is achieved with the control system inherent to manufacturing processes which allow better control of the waste generated and promote direct re-use and re-cycling at source. Mtech (Wrap 2007) shows that, in the worst cases, 40% of waste is saved onsite and only 1% is generated at the factory. Waste saving starts from the initial design approach, where waste is ‘designed out’ by optimising the use of materials, rationalisation of the design loads, and better controlling the supply chain. Offsite manufacturers use their supplier relationship to go beyond the traditional construction procurement approach by involving their suppliers in the reduction of waste from packaging, rationalisation and optimisation of the products to suit the manufacturing process (e.g. plasterboard delivered to fit whole walls). This extends to co-operation between manufacturers and suppliers where waste from the manufacturer is re-cycled or even re-used by the suppliers. Waste management and improvement systems (e.g. ISO 14000; Kaisen approach) involve employees at all levels in reviews of processes and methods to make them more effective and more cost efficient. Part of the exercise is to identify how to cut wasted material, time and energy! The same studies have demonstrated that the total use of energy is at least 25% better for offsite typologies when compared to the same construction activities carried out on construction site (traditional approach). This considered all the energy used for the maintenance of the buildings, the manufacturing process and the transport to and from the factory for deliveries of supplies and finished goods to site (including journeys by employees). However, the challenges for offsite are equally substantial, and not the least of these is to devise a solution which balances the manufacturer’s need to make a repetitive solution many times with an industry which generally designs a specific solution for every building.
© Woodhead Publishing Limited, 2010
Prefabricated building units and modern methods
18.3
431
Standardisation in construction
Mtech Consult has developed the following definition based on the BuildOffsite Glossary of Terms (2006): Standardisation is the widespread and systematic use of processes and components with repeated regularity in construction and engineering projects with the conscious objective of achieving optimum economy, quality and functionality. Unitisation and standardisation of layout and design increases the opportunity for offsite prefabrication of buildings and building components. When repeatable processes are incorporated in offsite production, additional time and resource can be applied to the design process, development, testing and manufacturing set-up, all of which reduces the unit cost and increases the product performance. This impetus for standardisation must not outweigh product saleability in a blind drive for a high degree of repetition at all costs. Even where standard buildings are not suitable, standardisation of bathrooms, kitchens, tank/boiler cupboards and other elements can realise much of the benefit. These are typically the high value and labour intensive parts of a building but standardisation principles can be applied to any part of the construction where it will create a sufficient volume of repetitive components to make offsite manufacture more viable. These are the principles increasingly being applied in all industries, often described as ‘mass customisation’, which enables them to reduce design, manufacturing and tooling costs as well as simplifying the processes and reducing the reaction times to new trends and demands. The benefits of this are seen all around us with the reducing cost and improving quality of most of the everyday products we come in contact with and the same approach is what will allow us to see similar benefits in the built environment.
18.4
Types of offsite construction
The following definitions provide a summary of the more common offsite construction types, demonstrating the breadth of approaches being adopted to transfer existing construction processes from onsite to offsite. Offsite is not limited to the prefabrication of volumetric or large scale components; manufacture of complex components or building elements which are highly repetitive also benefit from being factory assembled. This list is far from exhaustive; it is intended to establish a common, basic understanding of the offsite construction sector, its building systems and its technologies. New technologies are emerging constantly from around the world as creative minds turn their attention to new and better ways of creating the built environment. © Woodhead Publishing Limited, 2010
432
Materials for energy efficiency and thermal comfort in buildings
18.4.1 Volumetric buildings These are buildings supplied as a 3D element, volume or box. Portable and relocatable buildings These are designed to be easily dismantled, moved and relocated. They may be modular (made up of a number of building slices) or single volumes (where they are transported as complete buildings). They are mostly designed as temporary or semi-permanent accommodation and have a relatively short lifespan of 15–30 years, due to choice of materials rather than workmanship (Fig. 18.1). Typical uses are toilets; office accommodation; canteens; site storage and offices, so internal finishes are generally hard wearing, prepainted steel or pre-vinyl covered plasterboard. Volumetric (modular) building systems These are offsite manufactured buildings that are permanent with a lifespan from 30 to over 60 years. They are generally comparable in performance to traditionally constructed buildings. Certain designs can be fully relocatable (Fig. 18.2). Volumetric modular building systems are currently used in a wide range of sectors including: ∑ ∑
Education – classrooms, storage, laboratories and staff facilities Leisure and hotels – rooms with en-suite bathrooms
18.1 Example of a portable/re-locatable building (courtesy of Thurston Building Systems).
© Woodhead Publishing Limited, 2010
Prefabricated building units and modern methods
433
18.2 Example of a volumetric (modular) building (courtesy of Thurston Building Systems).
∑ ∑ ∑ ∑ ∑ ∑
Healthcare – wards, laboratories and highly serviced facilities Commercial and industrial – garage forecourts, shops, office accommodation, storage facilities, workshops Housing – private and social housing MoD – barracks and officers’ living quarters Custodial – detention centres and prisons Institutional – student accommodation.
Volumetric modular building systems are generally provided with a temporary external finish prior to leaving the factory and then re-clad and finished onsite by a specialist sub-contractor. However, some systems have factory applied, fully weathered, external cladding, but jointing and some degree of site applied finishing is usually required. Internal finishes are factory applied, generally to a more advanced level, such as tape and jointed plasterboard or plasterboard with a skim finish and may well include factory applied paint coatings. In the more prestigious/higher quality modular buildings, there is a trend to use lightweight thin screed and concrete floors, supported on lightly profiled metal decking trays and floor joists. Park homes and caravans Leisure homes have little resemblance to early static caravans. Today, residential park homes are designed for permanent, holiday, retirement
© Woodhead Publishing Limited, 2010
434
Materials for energy efficiency and thermal comfort in buildings
or second home living and look like traditional detached bungalows. Manufactured in factory-controlled environments, usually offering standard ranges of styles and layouts, constructed using a variety of system types, including steel or timber frame and structural insulated panels (SIPs), these buildings offer a high performance specification for their cost. They are completed offsite with kitchen, bathrooms, plumbing, heating and electrical fit out, then transported to their final destination, where they are sited and then connected to mains services.
18.4.2 Pods and room modules These are a hybrid form of construction where ‘whole rooms’ are prefabricated in the factory but the rest of the building can be finished with either traditional or offsite panel construction. Pods These are small, complete volumetric rooms, constructed using light steel frame (LSF), timber, concrete or glass reinforced plastic (GRP), fitted out in a factory including all cabling and pipework, then installed into a preengineered space in a building onsite. Pods are commonly used for bathrooms, shower rooms, washrooms and for kitchens. Pods may be non-structural or structural load bearing, depending upon the overall building design strategy (Figs 18.3 and 18.4). Room modules Larger and more complex pods are often referred to as ‘room modules’ and may be used for washrooms, hotel rooms or single living accommodation for students or the military. These are self-contained rooms, manufactured offsite with their own superstructure. Again, where possible, all mechanical and electrical cabling and pipework will be factory fitted, allowing final connections onsite.
18.4.3 Panel systems These are where the elements are supplied in 2D flat panel format. Light steel frame These are build systems that use cold-formed steel as the primary structural material, typically formed into storey height panels in the factory, or sometimes stick built onsite. In practice, light steel frame panels are designed to be
© Woodhead Publishing Limited, 2010
Prefabricated building units and modern methods
435
18.3 Author’s photograph of a bathroom pod installation.
maintained in warm and dry conditions and corrosion is avoided. This is known as the ‘warm frame’ principle (Fig. 18.5). Timber frame These are stick build or panellised systems that use timber as the primary structural material. They consist of pre-engineered frame elements, fixed together to erect a skeletal structure that is then enclosed and finished onsite (Figs 18.6 and 18.7). These are normally delivered in flat pack form, comprising walls, floors and roof panels. Timber frame construction has won wide acceptance amongst UK developers, specifiers and the social housing market as an effective, cost efficient and environmentally sustainable method of construction: ∑
‘Open cell panel’ systems are bare panels of studs with an external
© Woodhead Publishing Limited, 2010
436
Materials for energy efficiency and thermal comfort in buildings
18.4 Bathroom pods (courtesy of Rasselstein UK).
18.5 Example of light steel frame construction (courtesy of Engineered Offsite Systems Limited).
∑
sheathing board, delivered to site to have the cladding, insulation, services and finishes installed in situ. ‘Filled cell panel’ systems are panels inclusive of insulation, electrical and plumbing services and vapour control layer to support and protect the insulation during transport – but with no internal lining applied.
© Woodhead Publishing Limited, 2010
Prefabricated building units and modern methods
437
18.6 Example of timber frame construction (courtesy of Prestoplan Limited).
18.7 Example of timber frame construction (courtesy of Innovare Systems Limited).
∑
‘Closed cell panel’ systems are pre-engineered panels, inclusive of linings, insulation, electrical and plumbing services, doors and windows.
Structural insulated panels (SIPs) This is a form of construction used in panel building systems. Structural sandwich panels, typically comprising a core of foam with plywood, oriented strandboard (OSB) or cement bonded particleboard skins, are joined to form the superstructure of the building. Some manufacturers provide panels
© Woodhead Publishing Limited, 2010
438
Materials for energy efficiency and thermal comfort in buildings
inclusive of service ducts and voids for cables, but in most cases, mechanical and electrical services are positioned within service voids created by battens fixed to the panels. SIPs are well established in the United States and a substantial market is being developed in the UK, initially introduced in housing. They are increasingly used in general cladding, education and hotel construction. The glued joints and insulated core of these SIPs naturally result, in good airtightness, thermal and structural efficiency, although care must be taken at connections and around windows and doors to ensure that the detail is good enough to maintain the levels of good performance (Fig. 18.8). Concrete panel Concrete can be precast in a mould in a factory to form a sheet or panel material. Typically the bottom, mould face has a smooth fine surface and, with the addition of suitable reinforcement, these panels can be designed to create a panelised system for the construction of offsite buildings. Single skin walls will always have just one fair face and are well suited to external cladding applications where insulation and other finishes need to be applied to the other face, but forming double skin walls with two fair faces provides a solution for internal walls. Floors can be pre-stressed planks or solid. Joints between wall panels, floors, the flights and landings of the staircases are supported and interconnected by means of support angles, reinforcement and concrete infill and grouted joints (Fig. 18.9).
18.8 Example of structural insulated panels (courtesy of Innovare Systems Limited).
© Woodhead Publishing Limited, 2010
Prefabricated building units and modern methods
439
18.9 Author’s photograph of the ‘Kastell’ building system.
Applications have included student accommodation, hotels and prisons as concrete can command a premium in applications where robustness has a real value.
18.4.4 Mechanical and electrical services As the mechanical and electrical (M&E) element of a project can reach 30% or more of the timescale and cost, it is an area that can gain maximum benefit from the offsite approach. Offsite M&E services reduce the number of activities onsite and help speed up the build programme. At the smallest scale, offsite starts with domestic M&E solutions such as snap-fit electrical wiring solutions and push-fit jointless plastic plumbing systems. More recently there has been an increasing trend toward the prepackaging of boilers, water heaters and storage cylinders into a single unit. Ideally services should be designed so that they could be integrated into one end of a bathroom pod and have the pod supplier complete this element with the primary plumbing to a bathroom (or kitchen). In order to achieve the higher levels of sustainability targets, there has been a resurgence in the use of centralised combined heat and power (CHP) plants, often run on renewable bio-fuels. Centralised packages can be supplied as part of a modular plant room, complete with distribution networks which can be pre-assembled offsite. In another vein are modular stair products, a pair of stair flights packaged
© Woodhead Publishing Limited, 2010
440
Materials for energy efficiency and thermal comfort in buildings
in a steel frame with robust handrails, landings and half landings all in place from the factory, which allow safe, permanent access to upper levels to be installed as the frame of the building is erected. More recently this thinking has developed to include the lift shaft which can be pre-fabricated offsite to take another key item off the critical path.
18.4.5 Future trends and materials development In traditional construction most materials perform one role. The structure is distinct from the insulation which is separate from the weatherproofing. Outside of the construction industry, this would be highly unusual, as most manufactured products and components perform more than one role to maximise efficiency and effectiveness of both the materials and the processes. Offsite is one area of construction where this multiple functionality already exists. An example of this is the use of composite panels for both volumetric and panelised forms of construction, such as SIPs and precast insulated concrete panels. Here, the combination of an external grade sheet material, such as ply, OSB or steel, adhesively bonded to an insulating core material and a suitable internal lining, creates a wall, floor or roof component with many functions. It can provide a water and weatherproof layer; it can take structural axial and racking loads; by the use of the right materials it can provide fire protection and reduce the passage of sound through the fabric of the building; it can provide insulation and airtightness with the minimum of cold bridging and it can, in some cases, provide a visually acceptable, robust surface for the user. Although composite panel technology has been used for many years, the development of new materials and the tailoring of materials to the specific needs of the system provide plenty of scope for improved performance. These opportunities include: ∑
improved adhesive bonding to create stronger panels, speed up production or reduce the need for expensive, slow pressing operations to achieve a good bond ∑ new sheathing materials to offer a better aesthetic appeal or feel at a lower cost, with a longer life ∑ combinations of existing or new materials to improve performance in fire, sound or thermal performance or the required combinations of all these physical properties.
18.5
Comfort factors in lightweight buildings
Buildings primarily provide shelter, warmth, shading and security in varying degrees depending upon the climate and local custom. After these © Woodhead Publishing Limited, 2010
Prefabricated building units and modern methods
441
fundamentals have been addressed, comfort is high on the occupants’ list of requirements. Comfort is a relative term and, when applied to a building or occupied space, can be defined in a number of ways. Human comfort factors are subjective and can be skewed by age, gender, visual cues, clothing and state of mind. ‘Human thermal comfort is essentially a subjective response or state of mind where a person expresses satisfaction with the surrounding environment’ (ASHRAE 2004). Human thermal comfort is affected by heat and evaporative heat loss, and can only be maintained when the heat generated by the body’s own metabolism is allowed to dissipate, ensuring a maintained thermal equilibrium within the internal environment. If the internal environment is such that this equilibrium cannot be maintained (body heat loss or gain) then discomfort is felt. Ensuring building occupants remain comfortable does not just rely on air temperature alone. Buildings have to be designed using the 3Ls principles (long life, low energy and loose fit) and with building design life in excess of 50 years, have to be able to absorb and deal with future climate change and change of use without major remodelling. The ability for any building to cope with the changing environment over such a long period depends upon the makeup and durability of the building fabric, the quality of the workmanship, loose fit design and some measure of scheduled maintenance or refurbishment programme. The necessity to design new materials and systems to cope with the changing environment whilst providing a sustainable approach to both the construction and lifespan of the building is paramount.
18.6
Design led materials for addressing lightweight performance issues
With a ‘solutions’ approach to advancing system design, the potential for offsite to satisfy and exceed the future requirements for sustainable energy efficient buildings is vast. New ‘smart’ materials combined with high quality assembly will ensure designed performance for the life of the building. Major factors affecting the long-term performance of lightweight buildings relate to the ability to effectively regulate the internal environment in a sustainable way for the life of the building throughout all aspects of climate change, whilst maximising the comfort factors which modern day living demands. The ability to effectively control the internal environment in a sustainable way means that the temperature, moisture and air quality needs to be balanced to provide an acceptable comfort level whilst at the same time ensuring the fabric of the building does not become compromised by external or internal moisture penetration, and the solution is sustainable long term.
© Woodhead Publishing Limited, 2010
442
Materials for energy efficiency and thermal comfort in buildings
18.7
Delivering sustainable comfort: a question of balance
Delivering sustainable comfort in any form of building is complex as the process is dynamic; differing building systems both old and new face these ongoing challenges with every change in season, change of use or occupancy level. All buildings irrespective of their construction type and age are governed by the laws of physics, and by applying the rules of ‘building physics’ early in the design process, the well-being of the occupants and the building envelope can be predicted and ‘designed in’. Building physics is the cornerstone of designing, constructing, and operating high performance buildings, that is, buildings that are durable, comfortable, energy efficient, affordable and healthy. To avoid or solve many building problems, a unique mix of heat and mass transfer physics, material science, meteorology, construction technology, human physiology, and engineering analysis and design must be applied. This mix of knowledge and expertise is often called building science. It was initially developed and promoted in Europe (especially Scandinavia) where it is called building physics (Building Science Corporation). The two primary zones requiring controlling are the internal occupied space in which we live or work and the building envelope which encompasses the occupied space and forms the primary enclosure system. The fabric of the building (external walls, roof and floors) comprises the enclosure to the occupied space and is referred to as the ‘building envelope’. The building envelope’s primary objectives are: 1. 2. 3. 4.
structural capacity to carry dead and live loads moisture control – in and out of the building temperature control – in and out of the building control of air pressure – in and out of the building.
The building must be designed to ensure the building envelope does not suffer from either external or internal moisture-related problems. Often the first sign of building stress is when conditions have reached a critical point and the problem manifests itself visually. The fabric of the building can tolerate some short-term discomfort but in the long term, it needs to be kept dry and ventilated. Externally, the temperature, humidity and air quality may vary dramatically depending upon the local climate, topography and season. This has a major effect on the internal environment and the extent of the measures necessary to be ‘designed in’ to balance the extremes once the building envelope has played its part. The greater the differential between the external and internal conditions, the harder the building envelope or internal control system has
© Woodhead Publishing Limited, 2010
Prefabricated building units and modern methods
443
to work to deliver the desired environment and then maintain that balance through the extremes.
18.7.1 Temperature control Of the three primary factors cited, temperature is the one most easily assessed as we are used to deciding whether we are too hot or too cold; however, we are not very efficient at detecting relative humidity levels unless they are extreme. Lightweight buildings have perceived advantages and disadvantages when it comes to controlling the temperature of their internal environments. Whilst there are many differing lightweight construction types, most have very fast thermal response times (heating and cooling), high levels of airtightness and thick insulation, which provides highly energy efficient heat storage systems. However, the ability for a building to modulate the internal temperature fluctuations passively by use of thermal mass is desirable, especially when reviewing the likelihood of continued temperature rises due to global warming over the predicted lifespan of any new building. There have been a number of research projects (Arups DTI report 2004) which, as part of a wider review, question the ability of lightweight construction to perform in the future as climate changes drive up external temperatures; this refers primarily to the lack of thermal mass. The word ‘mass’ implies bulk, weight or both, neither of which are particularly easy to accommodate in lightweight structures. Whilst insulation levels can be improved to gain additional thermal performance giving rise to even faster thermal response times, it is not a complete solution to the lack of thermal mass. There are two fundamental approaches to controlling temperature and internal air quality in buildings: 1. passive 2. active. Both are valid and apply equally to temperature, moisture and air quality control. Although a strong case can be presented for the individual use of both passive and active techniques on their own, a balanced mix of both may be most appropriate for many building designs and conditions. Offsite processes can be intricate yet repeatable, leading to high quality component fit which ensures the resulting building matches the design requirements. This is vital to ensure the erected structure has not had its intended performance characteristics breached by poor building processes, or workmanship. High performance buildings require high performance manufacture and assembly, especially important for passive designs where airtightness and insulation fit are of paramount importance.
© Woodhead Publishing Limited, 2010
444
Materials for energy efficiency and thermal comfort in buildings
Passive design promotes the internal environmental control of temperature, moisture and air quality by natural means such as: ∑ ∑ ∑ ∑ ∑ ∑
natural ventilation airtightness efficient insulation solar shading solar heat gain controlled mass.
Active solutions may be used on buildings which have none, or all of the above and any mix in between. It can be used as the primary control system for temperature and moisture or as a ‘cut in’ for extremes that cannot be coped with under normal conditions. ‘Passive design’ based upon these fundamentals can eliminate the need for both mechanical heating and cooling by adopting all or some of these principles into the design depending upon construction choice and climate in which the building resides. Lightweight buildings can be built using pure passive design principles, or a combination of both. Build quality plays a major role in achieving a true passive designed building. Many of the ‘Passive House’ designs rely upon very thick walls and roofs to facilitate the high levels of insulation required, which adds to the building’s footprint either externally or internally depending upon how you view it, increasing the visual size of the building or reducing floor area. On a global basis, the additional footprint size may have little significance, but in highly populated countries such as the UK where land is scarce and costly, a reduction in footprint size is preferable to an increased one. Whilst offsite techniques can accommodate varying structural thicknesses, it makes sense for transportation and ease of erection to make the components, panels or systems as light and bulk free as possible. Techniques and materials which are thin, flexible and high performing are being designed to maximise the offsite principles.
18.8
Thin solutions (insulation and mass)
With growing pressure to keep new building footprints small, the drive for ‘thin wall’ solutions for both refurbishment and new build is growing. Ultra thin materials are also very useful for providing insulation and temperature modulation in areas of buildings where previously the constraints of the design did not allow space for adequate provision of either. Wall penetrations such as window and door openings provide classic examples of where ultra thin solutions work perfectly, as they are able to be fitted around the sides of the window and door reveals internally without it impeding the window frame.
© Woodhead Publishing Limited, 2010
Prefabricated building units and modern methods
445
Additionally, the majority of lightweight construction methods rely on a structural framework where the insulation sits in the same plane as the structure (between the structural studs and joists). As most frameworks have little or no insulation qualities, they bridge the gap between the cold and warm surfaces of the building envelope (thermal bridging). Ultra thin insulation such as Aspen Aerogel can be fitted at the extremity of the framework to provide a thermal break and thus improve the overall performance of the building element without adding to the footprint size.
18.9
Thermal mass in offsite potential
Thermal mass has been described as a ‘thermal battery’ as it can moderate fluctuations in internal living temperature by absorbing and releasing heat as internal conditions allow, whilst working passively. Thermal mass is a component of sustainable building design that acts passively to help control temperature fluctuations, and ideally should be used as part of the holistic design of the building once all of the factors affecting the performance of the building have been considered. Many old buildings have thermal mass ‘in built’ which occurs as an emergence factor from the original design as often at the time of construction thermal mass was not part of the design considerations. It just happens that the construction type had ‘mass’ due to its construction material choice. Optimising where and how the mass works is vital to accurately predicting how the temperature in the building will be modulated over a variety of temperature ranges and conditions. With refurbishment and thermal upgrading of old buildings (especially the range of ‘hard to heat and hard to treat’ single skin buildings) many are having the thermal mass benefit reduced by ‘decoupling’ the mass from the living environment by the introduction of an air gap as often the wall will have ‘plasterboard on dabs’ applied.
18.10 Phase change materials (PCMs) Phase change materials (PCMs) are materials which change their physical characteristics when absorbing or releasing heat/energy. The materials vary in the ‘phase time’ and temperature range at which they melt or freeze. (Ice is a prime example of a PCM.) PCMs enable the principles of thermal mass to be applied to lightweight buildings and building elements without affecting the major benefits of the system approach. Lightweight and thin PCMs provide the designer with the potential to incorporate thermal mass in the most appropriate locations of a building, to maximise the benefits of the thermal capacity, thus delivering the possibility to ‘fine tune’ the building envelope to maximise the potential for passive
© Woodhead Publishing Limited, 2010
446
Materials for energy efficiency and thermal comfort in buildings
storage and subsequent release of energy. (A factor which is often not possible with traditional mass as it is often a secondary function to its main purpose of providing part or whole of the support structure.) PCMs are not a new concept, but developments in technology have enabled them to be incorporated within the range of existing materials currently used in lightweight buildings. Wallboards, shutters, external cladding and internal plasters can be manufactured to contain PCMs; the resulting element will remain ‘thin’ and relatively lightweight. The term ‘lightweight thermal mass’ may appear to be a contradiction in terms, but effectively it does describe these characteristics – ‘virtual thermal mass’ may be a more appropriate term. Rechargeable batteries store and release electrical energy; phase change materials perform a similar function for thermal energy. For example, PCM wallboard can remove excess heat from a room during the day and release it at night, with minimum use of energy and CO2 emissions; unlike air conditioning units. Global legislation on climate change is driving sustainability issues and the development of phase change materials technology can help to ensure that stringent environmental targets are met. There is increasing research effort into phase change materials for both passive and active systems for room temperature regulation and the storage of both heat and cold (Ian Biggin, Ciba 2009). PCMs are also being used in furniture, kitchen work surfaces and other areas where temperature balancing or buffering may be desirable or localised. In normal use, these types of elements may not be considered as part of the structure, but with modular construction techniques and volumetric pod systems, these types of items may be standard fitment and be used as part of the overall comfort strategy.
18.11 Advancements in phase change materials for buildings The surface spread of flame on construction materials is of prime concern with all building types; none more so than with lightweight structures as often the primary structure comprises timber or light gauge steel. One of the problems associated with the most common types of PCMs was its tendency to burn, as it is based on encapsulated liquid wax technologies. Recent developments amalgamating PCMs into a wood-based matrix have enabled the benefits of micro-encapsulated liquid wax to be added to internal lining boards, shutters and cladding whilst being fireproof, offering real potential to provide virtual thermal mass for lightweight buildings to be used in designspecific locations without fear of fire spread.
© Woodhead Publishing Limited, 2010
Prefabricated building units and modern methods
447
18.11.1 Moisture control Moisture vapour is a gas and remains as a gas until it condenses; in the liquid form it poses a threat to the building fabric whereas if it remains in the vapour state whilst passing through the building fabric it is inert. If saturation point or ‘dew point’, as it is commonly known, is reached within the building fabric, vapour condenses and becomes liquid, referred to as ‘interstitial condensation’. In this form it is harmful to the fabric of the building if it cannot escape or revert back to a vapour again. Moisture vapour laden air can enter the fabric of the building externally or internally and requires climate sensitive designs to dictate where the air or vapour barriers should be placed. Climate dictates external temperature and relative humidity, and in turn the building envelope needs to be designed to cope with extremes experienced and predicted over the lifetime of the building. Any form of water penetration into the fabric that has not been designed for is damaging. Water ingress can occur for many reasons: ∑ ∑
Envelope failure – workmanship, bad detailing or inadequate materials. Service failure – leaking water pipes, washing machines or drains.
With global warming giving rise to increasing wind speeds, variant temperature extremes and horizontally wind driven rain, the likelihood of water ingress through poor detailing or bad workmanship is growing. Offsite can mitigate some of the potential for water ingress by raising the level of workmanship; however, the tighter the external envelope is sealed, the greater becomes the chance of water entrapment should it gain entry, as its ease of exit has been impeded. Whatever the reason for water penetrating the fabric, it has to be able to dry out and return to its designed state.
18.11.2 Airtightness The control of air leakage and airtightness are both one and the same, although confusion exists between the two. Confusion also exists between vapour barriers and air barriers. It is vital that lightweight buildings are designed with a full understanding of each and the appropriate mix of the two are used in a design-specific way according to the existing and future climates in which the building has to function. The primary reason to seal and control the movement of air into and out of a building is to achieve airtightness, as a ‘leak free’ building envelope aids internal temperature control and energy conservation. There are a number of ways in which airtightness can be achieved, by applying the principle airtight membrane either on the external or internal faces of the envelope. Whilst both provide an airtight solution, they have differing effects on the fabric of the building. © Woodhead Publishing Limited, 2010
448
Materials for energy efficiency and thermal comfort in buildings
Externally applied air barrier systems control the air passing into the structure itself, which has benefits where external moisture laden air is present or the building fabric comprises open cell insulation which could be cooled by air infiltration. Internally applied air barrier systems also control air infiltration into the building, but applied at the internal face usually behind the internal lining board. Both externally and internally applied air barriers have perceived advantages and disadvantages when considering the way the building envelope is designed to function and, if viewed globally, legislation may force the use of one or other type of system.
18.11.3 Membranes Lightweight buildings rely heavily on membranes to provide both air and moisture control either to the inside face, external face or in some cases both faces of the building envelope. But before considering future membrane development, some basic understanding of membrane types is required, as their differences and functions are often misunderstood – there is confusion between air and moisture permeable membranes, what combination of each are required and at what location on a building they are to be placed. Membranes can be: ∑ moisture vapour permeable, but airtight ∑ moisture vapour tight and airtight ∑ moisture vapour permeable and air permeable. Depending upon the design characteristics of the building envelope, one or more of the above can be applied to external, internal or both faces to control the effects of moisture vapour and air passing through the building envelope. Vapour permeable does not mean that it will allow water to pass through it, only water vapour, so all are watertight if poor workmanship and detailing are ruled out. Ideally, the combination of membranes should be designed to stop unwanted air infiltration (into either the building element or the occupied space) and at the same time allow moisture vapour to flow into or out of the building envelope or occupied space freely, without it ever reaching dew point within a part of the envelope that it was not intended to deal with it.
18.12 New membrane developments Membranes are primarily preventative rather than reactive and usually single function. But new technologies and advancements in glues and resins have enabled the development of a new range of membranes that are dual function, and able to actively ‘draw out’ entrapped moisture from the building fabric.
© Woodhead Publishing Limited, 2010
Prefabricated building units and modern methods
449
Partnering between Apollo Adhesives, Ciba Chemicals and the offsite industry has led to the development of smart glue which contains moisture ‘swellable’ polymers that actively draw moisture into the glue matrix and pass it through the glue and out of the membrane harmlessly as moisture vapour when conditions permit. This is factory applied to the inner face of the membrane, which is then factory or site applied to the building fabric where it functions as an airtight but vapour permeable layer. In similar vein, the same technology can be applied to rubber seals for use around window and door apertures, allowing free air and moisture vapour transmission in their natural state, but which will swell once water breaches the detail. The rubber seal returns to its original state and size as the entrapped water is released as water vapour when conditions permit. The ability of adhesives to provide more than one function is evident with adhesives containing nanoparticulate hydrophobic particles. These systems have been proven to allow the passage of moisture through the adhesive layer. These adhesives can be used in combination with breathable membranes to remove moisture out of water damaged buildings (Darrell Tibbins, Apollo Adhesives).
18.13 Composite design Offsite is beginning to take full advantage of mixing materials to obtain the maximum from the design. Green roofs and green walls have great sustainable credentials, but their system design did not fit well with offsite construction techniques. One of the difficulties has been the provision of a structural waterproofing system which could carry the loads, be flexible enough during construction, delivery and assembly and yet remain totally waterproof throughout. Traditional reinforced concrete would fill this need if it were not for its weight and thickness.
18.13.1 Ultra thin flexible reinforced concrete membrane Thin, lightweight products which have flexibility make ideal components for preassembled panels or pods. Materials with additional attributes such as fireproof, waterproof, strength and a long life add to that desirability. Lightweight offsite buildings are often ‘finished’ externally with lightweight cladding and roofing materials (either applied in the factory or onsite). These light systems do not all have the durability, fire and security performance of heavier solutions, such as masonry, which makes them vulnerable to physical damage and vandalism. One new material solution which can address this is Krete, a thin (6 mm) reinforced concrete membrane which is completely airtight, watertight and yet vapour permeable. It can be used on flat or vertical surfaces as a
© Woodhead Publishing Limited, 2010
450
Materials for energy efficiency and thermal comfort in buildings
complete waterproofing system to provide total encapsulation of flat roofs, upstands and walls. It is flexible and is applied ‘jointless’, which removes the problem of site assembly weaknesses. It provides a totally waterproof and strong flat roofing layer, making it ideal for use with green roofing systems, enabling lightweight structures to have complete roof assemblies factory fitted in readiness for the greenery to be added onsite. Furthermore, its inherent strength characteristics negate the use of additional root barrier protection. This material also has considerable potential for use in bathroom and kitchen pods, as its strength and flexibility along with the fact that it is totally waterproof makes it ideal for use in ‘thin floors’, wetroom floors and walls. RoofKrete has been used to make boats in the past, so it seems only natural to me that it is gaining interest from those seeking lightweight and flexible building solutions which have long life, good sustainable credentials and are totally waterproof. RoofKrete has been fully tested and given a functional maintenance free life of over 100 years (Dr Roy Jenkins, Krete Sustain Ltd).
18.13.2 The human factors Most people with an interest in construction and materials naturally concentrate on the ‘hardware’, the product and the materials, at the expense of the process. But the process, particularly the onsite process which completes the use of offsite elements, is at least as important to saving time, increasing control and so reducing costs and improving quality. The benefits of using offsite elements within a primarily onsite build process are certainty of product design, quality and delivery to the construction programme. It allows site professionals to develop standardised, rule-based approaches to construction issues, such as the order in which tasks are carried out.
18.13.3 Knowledge sharing Knowledge is often secured and secreted within pockets of industry, and in the past an unwillingness to share this knowledge has prevailed. The adage ‘knowledge is power’ is giving way to a greater understanding that by combining differing knowledge bases, great advances can be made swiftly for the benefit of all, both commercially and environmentally. Partnering between industry and universities, chemists and all manner of facilitators is giving rise to development of new materials and systems with specific characteristics ‘built in’ to satisfy a weakness in the building envelope, either as a single material or component part.
© Woodhead Publishing Limited, 2010
Prefabricated building units and modern methods
451
18.14 References BuildOffsite (2006) Glossary of Terms. Wrap (2007) WAS003-001: Summary Final Report, Current Practices and Future Potential in Modern Methods of Construction.
18.14.1 Offsite construction – reading list General off-site construction ARUPS Research and Development Report for DTI Partners in Innovation Programme 2004. ASHRAE – Standard 55 2004. Blismas, N, Pasquire, C, Gibb, A G F (2006) Benefit evaluation for off-site production in construction – Construction Management & Economics 24 February 121–130. Egan, J (1998) Rethinking Construction: the report of the construction task force, The Office of the Deputy Prime Minister (URL: http://www.constructingexcellence.org. uk/resources/publications/deault.jsp). Everett, J G (1993) Design fabrication interface: construction vs manufacturing. Proc. 10th ISARC. Gibb, A G F (1999) Off-site Fabrication: prefabrication, pre-assembly and modularisation, Whittles Publishing Services, ISBN: 978-0-470-37836-6. Gibb, A G F, Isack, F (2003) Re-engineering through pre-assembly: client expectations and drivers. Building Research & Information 31 (2) 146–160. Goodier, C, Gibb, A (2007) Future opportunities for Offsite in the UK. Construction Management and Economics 25 (6) 585–595. Gosling, J, Naim, M, Sassi, P, Iosif, L (2008) Flexible buildings for an adaptable and sustainable future – 24th ARCOM, Cardiff, 1, 115–124. Horner, M, Duff, R (2001) More for less: a contractor’s guide to improving productivity in construction. CIRIA C566. Kose, S (1997) Building Research Institute in Japan: past, present and future. Building Research and Information 25 (5) 268–271. Li, H, Guo, H, Skibniewski, M J, Skitmore, M (2008) Using the IKEA model and virtual prototyping technology to improve construction process management. Construction Management and Economics 26 (9) 991–1000. Manley, K (2008) Against the odds: small firms in Australia successfully introducing new technology on construction projects. Research Policy 37 (10) 1751–1764. McEvatt, W (1987) Modular co-ordination. Building Research and Information, 15 (1) 17–21. Nam, C H, Tatum, C B (1997) Leaders and champions for construction innovation. Construction Management and Economics 15 (3) 259–270. National Audit Office (2001) Modernising Construction (URL: http://www. constructingexcellence.org.uk/resourcecentre/publications). Pan, W, Gibb, A G F, Dainty, A J (2007) Perspectives of UK house builders on the use of Offsite modern methods of construction – Construction Management and Economics 25 (2) 183–194. Pasquire, C, Gibb, A G F, Blismas, N (2005) What should you really measure if you want to compare prefabrication with traditional construction? Proceedings IGLC 13, Sydney, Australia July 481–491.
© Woodhead Publishing Limited, 2010
452
Materials for energy efficiency and thermal comfort in buildings
Pries, F, Janszen, F (1995) Innovation in the construction industry: the dominant role of the environment. Construction Management and Economics 13 (1) 43–51. Reinschmidt, K F, Griffis, F H, Bronner, P L (1991) Integration of engineering, design and construction. J. of Const. Eng & Management 117 (4) 756–772. Ross, K, Cartwright, P, Novakovic, O (2006) A guide to modern methods of construction – HIS BRE Press on behalf of NHBC Foundation Vol NF1 Issue December. Stirling, C (2003) Off-site construction: an introduction, Building Research Establishment Publications, GBG 56, ISBN 1 86081 624 X. Tam, V W Y, Tam, C M, Ng, W C Y (2007) On prefabrication implementation for different project types and procurement methods in Hong Kong. Journal of Engineering Design and Technology 5 (1) 68–80. Tatum, C B (1987) Process of innovation in construction firm. J. of Const. Eng & Management 113 (4) 648–663. Winch, G (1998) Zephyrs of creative destruction: understanding the management of innovation in construction. Building Research and Information 26 (4) 268–279.
Housing Bottom, D, Gann, D, Groak, S, Meikle, J (1994) Innovation in Japanese Prefabricated House Building Industries, Construction Industry Research & Information Association (CIRIA), Westminster, London. Brock, L, Brown, J (1999) The Prefabricated House in the Twenty-First Century: What Can we Learn from Japan?, A case study of the KST-Hokkaido House (URL: http:// timber.ce.wsu.edu/Resources/papers/4-2-3.pdf). Burns, C J (2001) A manufactured housing studio: home on the highway. Journal of Architectural Education 55 (1) 51–57. Chowdery, M et al. (2002) Homing in on Excellence: a commentary on the use of off-site fabrication methods for the UK house building industry, The Housing Forum, London (URL: http://www.constructingexcellence.org.uk/resourcecentre/publications). Gann, D (1999) Flexibility and Choice in Housing, The Policy Press, University of Bristol, ISBN 1-861340893. Gann, D (2000) The Housing Demonstration Projects Report: improving through measurement, The Housing Forum, London. Malpass, P (2003) The Wobbly Pillar? Housing and the British Postwar Welfare State. Journal of Social Policy 32 (4) 589–606. Meiling, J, Johnsson, H (2008) Feedback in industrialised housing: why does it not happen? 24th ARCOM, Cardiff, 1, 145–154. Parliamentary Office of Science and Technology (2003) Modern Methods of House Building, No. 209, December (URL: http://www.parliament.uk/documents/upload/ postpn209.pdf). Venables, T, Barlow, J, Gann, D (2004) Manufacturing Excellence: UK capacity in Offsite manufacturing, The Housing Forum, Innovation Studies Centre, Imperial College London (URL: http://www.constructingexcellence.org.uk/sectors/housingforum/ publications.jsp).
Light steel frame Lawson, R M, Grubb, P J, Prewer, J, Trebilcock, P J (1999) Modular Construction using
© Woodhead Publishing Limited, 2010
Prefabricated building units and modern methods
453
Light Steel Framing: an architect’s guide, Steel Construction Institute, Publication P272, ISBN 1 85942 096 6. Steel Construction Institute, Case Studies on Modular Steel Framing, Publication P271, ISBN 1 85942 095 8. Steel Construction Institute, Case Studies on Light Steel Framing.
Volumetric modular Neale, R, Price, A, Sher, W (1993) Prefabricated modules in construction, Chartered Institute of Building (CIOB), ISBN 1 85350 061 9. The Housing Forum (2001), Modular construction for process efficiency and product quality, The Construction Best Practice Programme (URL: http://www.constructingexcellence. org.uk/sectors/housingforum).
Pre-assembly and standardisation CIRIA (1999) Standardisation and pre-assembly – adding value to construction projects, Construction Industry Research and Information Association, Report No. 176, London. Gibb, A G F (2000) Standardisation & Pre-assembly – Clients Guide and Toolkit, Construction Industry Research & Information Association (CIRIA), London. Gibb, A G F (2001) Standardisation and customisation in construction: a review of recent and current industry and research initiatives on standardisation and customisation in construction, CRISP Consultancy Commission – 00/20, May (URL: http://www. ncrisp.org.uk). Gibb, A G F (2001) Pre-assembly in construction: a review of recent and current industry and research initiatives on pre-assembly in construction, CRISP Consultancy Commission – 00/19, May (URL: http://www.ncrisp.org.uk).
Mechanical and electrical services Wilson, D G, Smith, M H, Deal J (1998) Prefabrication & Pre-assembly: applying the techniques to building engineering services, BSRIA, ISBN 0860225054.
18.14.2 Suggested reading Goffin, K, Mitchell R (2005) Innovation Management: strategy and implementation using the pentathlon framework, Palgrave Macmillan, ISBN: 1-4039-1260-2. Herbert, G (1978) Pioneers of Prefabrication – the British contribution in the 19th century, The Johns Hopkins University Press, ISBN: 0-8018-1852-4. Hvam, L, Mortensen, N H, Riis, J (2008) Product Customization, Springer, ISBN: 9783-540-71449-1. Myers, D (2008) Construction Economics – a new approach, 2nd edn, Taylor & Francis, ISBN: 0-415-46229-0. (Economics of OSC, Chpt 9 p154 ‘Offsite Construction Methods’). Ortiz, C A (2006) Kaizen Assembly – Designing, Constructing and Managing a Lean Assembly Line, Taylor & Francis, ISBN: 0-8493-7187-2.
© Woodhead Publishing Limited, 2010
454
Materials for energy efficiency and thermal comfort in buildings
Powell, C G (1980) An Economic History of the British Building Industry 1815-1979, The Architectural Press Ltd, ISBN: 0-85139-194-X. Stone, P A (1983) Building Economy – Design, Production and Organisation – a synoptic view, 3rd edn, Pergamon Press, ISBN:0-08-028678-X (Part II Chpt 7 ‘Innovation in Construction’, Chpt 8 ‘The Industrialisation of Building’, Chpt 9 ‘The Economics of Industrialised systems’ and Chpt 10 ‘The Mechanisation of Construction’).
18.14.3 Internet links Building Research Establishment (URL: http://www.bre.co.uk/) Building Services Research and Information Association (URL: http://www.bsria.co.uk/) Constructing Excellence (URL: http://www.constructingexcellence.org.uk/) Construction Industry Research and Information Association (URL: http://www.ciria.org.uk/) Construction Research and Innovation Strategy Panel (URL: http://www.ncrisp.org.uk/) Immprest (URL: http://www.lboro.ac.uk/research/immprest/) The Modular and Portable Building Association (formerly the National Prefabricated Building Association) (URL: http://www.mpba.biz/) PrOSPa – Promoting Off-site Production Applications (URL: http://www.prospa.org/)
© Woodhead Publishing Limited, 2010
19
Roofing materials for thermal performance and environmental integration of buildings
J. J o n e s, Virginia Tech, USA
Abstract: Roofs can represent 50–70% of the total enclosure loads for a building. The roof typically receives significant amounts of solar radiation and consequently represents both a concern for energy consumption as well as an opportunity for environmental expression. The roof is where the building meets the sky and therefore the design of the roofing system should consider not only the materials and construction characteristics but also the possibilities for environmental integration. This chapter presents issues and design strategies for the roof being an active participant in environmentally responsive architecture. The issues presented include: the construction and selection of materials for thermal performance and reuse or recycling, active solar collection, natural ventilation, and rainwater harvesting. An introduction is given to emerging roofing systems such as bio-composite materials and green roofs as well as fundamental performance issues such as sol-air temperature. Tables are included as references for thermal properties of common roof materials as well as solar absorptance properties of various roof weather protection layers. Key words: roofs, roofing systems, integrated building systems, environmental expression.
19.1
A question of design
Architectural design involves the exploration and evaluation of alternative propositions in response to many questions, some tangible others less so. Unfortunately, seldom does it seem in contemporary architecture is the question asked: How should the building meet the sky? Arguably through this question architecture can best express a response to regional differences in site, climate, sun and culture. Historically the roof was the building’s hat worn to speak to these differences. The pitched, thatched roofs of hot humid locations such as in the islands of the Caribbean or South Pacific effectively shed rain while dissipating heat from solar radiation (Fig. 19.1). The steeply sloped roofs of Cape Cod houses in the Northeast US or of Northern Europe are designed to prevent the accumulation of snow and avoid large live loads on the building structure. Low slope roofs in hot arid regions such as Northern Africa, the Middle East, Mexico and the Southwest US are typically constructed of light colored, high mass materials such as adobe, compacted earth, or concrete to first reflect and then delay the impact 455 © Woodhead Publishing Limited, 2010
456
Materials for energy efficiency and thermal comfort in buildings
19.1 Thatched roof structures from the Caribbean and Pacific islands shed rain and dissipate solar radiation.
of the sun from excessively hot days to cool nights. In these situations the construction of the roof tells a story about the regional conditions that the building responds to. While the question of ‘How should the building meet the sky?’ is seldom asked, a few recent projects do demonstrate the role the roof can play toward effectively responding to local environmental conditions. The British Pavilion by Nicholas Grimshaw for Expo ’92 in Seville, Spain (Fig. 19.2a), is an elegant statement of building meeting the sky where a series of curving rooftop panels integrate photovoltaic cells to convert sunlight into electricity while also acting as a shading canopy. The Tjibaou Cultural Center by Renzo Piano (Fig. 19.2b), borrows from the thatched roofs of the indigenous Kanak people in New Caledonia as inspiration for a series of curving doubleskin ‘cases’, where walls merge with the roof to rise on the landscape and respond to the prevailing winds for natural ventilation. Similarly the gentle
© Woodhead Publishing Limited, 2010
Roofing materials for thermal performance and environmental
457
(a)
(b)
(c)
19.2 Environmentally responsive roof solutions: (a) Nicholas Grimshaw’s British Pavilion (Humm & Toggweiler 1993: 45), (b) Renzo Piano’s Tjibaou Cultural Center (Buchanan 2000: 95), and (c) Thomas Herzog’s Hall 26 (Jones 1998: 171).
© Woodhead Publishing Limited, 2010
458
Materials for energy efficiency and thermal comfort in buildings
wave-like curves of Thomas Herzog’s Hall 26 in Hannover, Germany (Fig. 19.2c), admit daylight while compressing and accelerating the wind flowing over the building to induce a draught that draws warm stale air out of the building through carefully designed openings at the crest of the roof waveforms. These projects demonstrate the expressive role that the roof can play in environmentally responsive architecture. When considering energy consumption, with the exception of fenestration, for many buildings the roof is the most significant envelope component. The influence of the roof on heating and cooling loads may range from nearly negligible for narrow plan multi-story buildings, to well over 50% for large area single story buildings such as schools or warehouses. The Oak Ridge National Laboratory reports that the roof can comprise 50–75% of a building’s total envelope loads (ORNL 2003). As the influence of the roof increases, care should be taken to properly specify the construction of the roof assembly and to explore opportunities for the roof to actively participate as an environmentally responsive feature. When specifying the design and construction of the roof, at least five issues should be considered: 1. design for reuse and minimal environmental impact at both the beginning and end of the system life, 2. thermal performance and solar control, 3. opportunities for active solar collection, 4. design for natural ventilation, and 5. opportunities for rainwater harvesting.
19.2
Roof construction
19.2.1 Decking layers Roofs are typically constructed of a structural system (beams or joists) either supporting or integral with a decking layer, an insulation layer and an exterior weather protection layer. For residential and light commercial frame construction, roof decks are typically wood planks, plywood, oriented strandboard (OSB), or cementitious wood fiber. These materials are usually lightweight and easily workable without heavy construction equipment. Wood-based roof decking is most appropriate for short-span installations of about 30.5 cm to 61 cm on center (12≤ to 24≤ between rafters) with relatively low structural load carrying requirements. Wood decking products typically have relatively low embodied energy when compared to steel or concrete, and are somewhat renewable, as many wood-based products can be re-grown in a relatively short period of time. Wood-based decking layers may add a small amount of resistance to heat flow but provide little thermal mass to the system. Thermal resistance values for plywood building boards
© Woodhead Publishing Limited, 2010
Roofing materials for thermal performance and environmental
459
range from 0.054 m2 K/W (0.31 ft2 F h/Btu) for 6.35 mm (0.25 inch) thick decks to 0.16 m2 K/W (0.93 ft2 F h/Btu) for 19 mm (0.75 inch) thickness; for vegetable fiber board about 0.165 m2 K/W (0.94 ft2 F h/Btu) for 9.5 mm (0.375 inch) shingle backer and 0.144 m2 K/W (0.82 ft2 F h/Btu) for 16 mm (0.625 inch) thick particle board. (ASHRAE 2005: table 4, ch. 25). While the wood decking does provide some resistance to heat flow, an additional insulation layer is typically required. When considering the environmental impact from building waste and design for reuse, typically wood frame construction does not lend itself to recycling. This is because nails and screws are often difficult and time consuming to remove. Use of alternative attachment techniques such as glues and adhesives also do not support disassembly while demountable fastening systems such as nuts and bolting are time-intensive to install or remove and increase initial costs. Recently developed decking products such as bio-composites are more responsive to waste management concerns through the use of more sustainable materials such as wheat, straw and soy. Companies such as Composite Technology Park (CTP) have developed engineered mixtures of glass-fiber and natural fiber, typically including bamboo, coir and jute fibers that are renewable and bio-degradable (Composite Technology Park 2008). In addition to being more environmentally friendly and structurally superior to common wood roof decking components, these products are resistant to water, fungus, mold and rot. Environ bio-composites Inc. has a similar line of products for roof decks made from agricultural fiber, sunflower hulls, wheat straw and soy-based resin (Environ Bio-composites 2008). Products such as these have the two-fold benefit of higher renewable source content and when discarded to landfills they biodegrade much quicker than typical wood decks. Roof decks for non-residential buildings typically support longer spans and carry greater structural loads for roof-top systems such as heating, ventilating and air-conditioning (HVAC), and for maintenance personnel and their heavy tools or equipment. To support these building systems, the roof deck is often reinforced or thickened by a few inches under these equipment. For example for poured concrete roof decks the concrete thickness is typically increased from about 10 cm (4 inches) to 15 cm (6 inches) or 20 cm (8 inches) directly under the HVAC systems. This additional mass helps absorb structural vibration while providing greater support. Non-residential roof decks are usually made of pre-cast concrete, prestressed concrete or corrugated metal (galvanized steel or aluminum) or fiberglass supporting poured-in-place concrete or poured gypsum. Concrete decking adds thermal mass to the system but offers little resistance to heat flow. When thermal performance is a priority, lightweight insulating concrete (k = 0.11 to 0.78 W/m K) (0.8 to 5.4 Btu in/h ft2 °F) (ASHRAE 2005: table 4, ch. 25) can provide the benefits of thermal mass while being more
© Woodhead Publishing Limited, 2010
460
Materials for energy efficiency and thermal comfort in buildings
resistant to conductive heat flow, although the structural performance and compressive strength may be lower. These concrete products have higher thermal resistance due to an aeration process that introduces very small air pockets into the concrete as it cures. The result is a lower density material with thermal conductivity as little as one-tenth or less of standard concrete, depending on the composition and density. Aerated concrete can be pouredin-place or pre-cast. Because of the common use of metal reinforcement bars or steel mesh in non-residential roof decks, poured concrete systems typically do not lend themselves to removal and reuse. As a result when the building is demolished these roof decks are often broken up and hauled to the landfill. Due to the high embodied energy associated with both steel and concrete, alternative construction procedures for both assembly and disassembly should be considered. For this a more desirable roof construction strategy may be to use either solid or hollow-core precast concrete planks that can be interlocked and span several meters between primary structural members (Fig. 19.3). At the end of the building’s useful life, the roof finish can be removed and the planks detached and recycled. The hollow cores also present an opportunity for active air flow integration through the roof to remove solar heat gain before it penetrates to the occupied zones of the building. One important consideration for the roof decking layer is whether to incorporate heavy construction with thermal mass to delay the effects of the sun and hot midday sol-air temperatures. For building types and climate zones with cooling-dominated operation, roof decks are often constructed of high mass materials such as concrete that delay the impact of the sun on the interior of the building. Typical high mass roof decks may contain as little as about 5–15 cm or more concrete, with corresponding thermal lags
19.3 Demountable precast concrete hollow-core roof decking.
© Woodhead Publishing Limited, 2010
Roofing materials for thermal performance and environmental
461
of from 1–4 h or more. This can delay the heat gain through the roof to later unoccupied hours thus reducing both energy consumption and cooling system sizing. Thermal capacitances for typical roof assemblies are given in table 18 of Chapter 30 of the 2005 ASHRAE Handbook – Fundamentals and range from 6800 J/m2 (0.6 Btu/ft2 °F) for sloped frame roofs to over 238000 J/m2 (21 Btu/ft2 °F) for concrete roof decks. While the most cost effective thickness of the roof thermal mass will depend on several factors related to building design, use, materials and climate, the optimum thickness should be determined through hourly energy modeling and life cycle cost assessment. Generally for buildings in temperate to hot climate zones, with longer cooling seasons, the higher cost of the mass roof decking materials will be economically justifiable.
19.2.2 Insulation layer In addition to the roof deck, insulation is typically required to reduce heat transfer through the roof assembly. Insulation products such as fiberglass blanket and batt are common for residential and small commercial buildings, while rigid insulation boards of expanded or extruded polystyrene or cellular polyisocyanurate are more frequently used for non-residential construction. Generally rigid insulation provides greater resistance to heat flow than other insulation types for similar thicknesses. Also, some rigid insulation materials such as beaded polystyrene may have a small percentage of recycled content or can be broken up and re-used as loose-fill insulation. Thermal conductivity properties for typical roofing insulation types are shown in Table 19.1. In recent years alternative roofing insulation materials such as cellulose are gaining popularity in part due to their negligible pollution during manufacture and relatively low embodied energy content when compared to Table 19.1 Common types of roof insulation (ASHRAE 2005: Chapter 30, table 4) Material
k-value W/(m K)
(Btu in/h ft2 °F)
Perlite Fiber board (organic bonded) Polyisocyanurate Perlite/polyisocyanurate composite Perlite/polyisocyanurate/perlite composite Wood fiber/polyiscyanurate composite Cellular foam glass Glass fiber board Expanded polystyrene Perlite/expanded polystyrene composite Wood fiber/expanded polystyrene composite
0.04–0.06 0.04–0.06 0.02–0.025 * * * 0.04 0.036 0.029–0.036 * *
(0.27–0.42) (0.30–0.40) (0.14–0.18)
(0.32) (0.25) (0.20–0.26)
*Note: Conductivity will depend on the composition and relative amount of each material.
© Woodhead Publishing Limited, 2010
462
Materials for energy efficiency and thermal comfort in buildings
rigid boards and fiberglass blankets. Made from recycled newsprint and other paper sources, and typically installed as loose-fill, cellulose insulations offer R-values of between 0.6 and 0.7 m2 K/W (3.6–4.0 h ft2 °F/Btu in). Because loose-fill cellulose volumetrically settles at a fairly high rate to approximately 80% of the initial level, the Insulation Contractors Association of America recommends an additional 25% thickness. (CIMA 2008). While cellulose insulating materials can be environmentally friendly, their application should be balanced with concerns that they tend to absorb and hold moisture, which can degrade the thermal properties, their fibers and chemicals (i.e. from ink) can be a skin and eye irritant, and they can be highly combustible and therefore are often treated with a fire retardant chemical. Minimum thermal insulation standards have been established by building codes for most building types and locations as discussed below. Installing the insulation above a thermal mass roof deck generally yields a higher performing thermal barrier. This location can also moderate deck temperatures which reduces thermal movement of the deck and the potential for underdeck condensation. Standards organizations such as the American Society of Heating, Refrigerating and Air-conditioning Engineers (ASHRAE) through ASHRAE Standard 90 – Energy Efficient Design of New Buildings Except Low-Rise Residential Buildings (ASHRAE 1989), allows for less insulation in the envelope when the insulation is placed outside of the thermal mass. According to the ASHRAE, ‘insulation can be placed above the membrane in a protected or inverted roof system. With this approach, the roof membrane is installed on the deck, where it functions as a waterproofing membrane and vapor retarder. Insulation can be placed above and below membranes to function both as the base and protector for the membrane,’ (ASHRAE 2005: 24.3) When placed above the membrane the insulation is usually protected by a ballast layer of gravel or pavers. This ballast layer can also help dissipate solar radiation on the roof as shown in Table 19.6. In the US, based on the Model Energy Code guidelines (Model Energy Code 2000), the following minimum roof insulation R-values are suggested for various geographic locations for typical building usage. ∑
Alaska, Southern Canada (approx. 5500–14000 HDD65 °F)
∑
New England, Upper Great Plains, Great Lakes, Mountain States (approx. 4500–10000 HDD65 °F)
∑
R = 4.4–7.0 m2 °K/W (25–40 h ft2 °F/Btu)
R = 3.5–4.4 m2 °K/w (20–25 h ft2 °F/Btu)
Mid-Atlantic, Great Northwest, Lower Great Plains (approx. 3500–7500 HDD65 °F)
R = 2.5–3.2 m2 °K/w (14–18 h ft2 °F/Btu)
© Woodhead Publishing Limited, 2010
Roofing materials for thermal performance and environmental
∑
West Coast, Southwest, Deep South (Approx. 500–3000 HDD65 °F)
∑
463
R = 2.1–3.0 m2 °K/w (12–17 h ft2 °F/Btu)
Gulf Coast, South Atlantic, Hawaii, Northern Mexico (approx. 0–2500 HDD65 °F)
R = 1.8–2.5 m2 °K/w (10–14 h ft2 °F/Btu)
In their book Sun, Wind and Light, Brown and DeKay divide North America into eight climatic zones for residential construction, each with recommended roof insulation thickness ranges. Recommended values range from as little as 150–350 mm (8–16 inches) for region R-1, hot arid zone of extreme southern California or Northern Mexico, to 400 mm (18 inches) for extreme Northern Alaska. For non-residential construction they divide the US into eleven climatic zones with corresponding recommended roof insulation thicknesses of from 100–150 mm (4–6 inches) for zone C1, extreme southern Florida (hot humid) to 450 mm (18 inches) in northern Alaska. (Brown & DeKay 2001). It should be noted that these recommendations are for thicknesses of batt insulation and if rigid insulation is used, as is common for non-residential construction, then the thickness could be correspondingly less as the R-values for rigid insulation are typically higher than for batt insulation. It should also be noted that these thickness are most economical given current purchased energy prices in the US. In Europe, which typically has higher energy costs, and as fuel prices escalate, more insulation may be justifiable. For reasons of constructability and moisture control, many roof assemblies often include one or more air layers. For near still air conditions the thermal resistance of an air space will depend on the position (horizontal, vertical or sloped), the direction of heat flow (up or down), the mean temperature of the air in the cavity, the temperature difference across the space, and the depth. As given in table 3 in ch. 25 of the 2005 ASHRAE Handbook – Fundamentals, the thermal resistance of an air space may range from as little as 0.13 m2 K/W (0.73 ft2 °F h/Btu) to nearly 2.3 m2 K/w (13 ft2 °F h/ Btu). The addition of a low emissivity (upper surface) or radiantly reflective (lower surface) material to one of the air space surfaces can approximately double the R-value for the air space. Pre-manufactured aluminum-faced rigid insulation boards or blankets are available for this purpose. It should be noted that these radiant control materials (such as aluminum) are intended for applications across an air space. When not applied in correspondence with an air gap and when brought into direct contact with another material, the high conductivity of aluminum-based materials often negates the radiant benefits. For residential, light commercial and other framed buildings such as some small schools, roofs are often assembled with an attic. When well sealed, the
© Woodhead Publishing Limited, 2010
464
Materials for energy efficiency and thermal comfort in buildings
attic adds a large air space that can act as a thermal buffer between inside and out. When insulated and unvented the typical assumption for heating load calculations is that the temperature of the attic will be near the mean of the indoor and outdoor temperatures. Consequently for heat transfer (Q = (k∙A∙DT)/d) the presence of an attic air buffer can significantly reduce the temperature difference (DT) across the insulation layer during the heating season. Unvented attics are most appropriate for locations with fairly severe heating needs and short cooling seasons. For locations and building types with relatively long overheating seasons, on the other hand, the sealed attic builds up heat and can be several degrees warmer than the ambient air temperature, depending on factors such as volume of the attic and absorptance of the exterior weatherproofing layer. This can significantly increase DT and the rate of heat gain to the occupied zones beneath the insulation layer. As a result, in locations such as the United States and Canada, attics are typically vented to remove heat and lower the interstitial air temperatures during overheated periods. For cold conditions it is typically assumed that the air temperature in a vented attic is equal to the outdoor air temperature. This two-season behavior suggests a seasonally adjustable venting system may be beneficial. During the underheating season the attic should be sealed by closing vent dampers. During the overheating periods it would be well vented by opening the dampers. This could be accomplished through thermostatically controlled vent dampers or power venting with temperature sensing and control. However, care must be taken not to draw moisture into the attic that could condense on cold surfaces. Roof vents may be classified as static or power vents, ridge vents, turbine vents, soffit/cornice vents, gable vents, starter vents or cupola vents. A common rule of thumb for sizing the vent system is the 1/300 rule: one square foot of net free vent area (NFVA) for every 300 square feet of roof or attic area (equivalent to ~ 0.09 m2 per 27 m2). The net free vent area is the portion of the opening in the vent that actually ventilates and accounts for obstructions from bug screens and louvers. The NFVA may be as little as 40% or less of the overall size of the vent (Roofhelp 2008).
19.3
Thermal performance of roofing materials
19.3.1 Solar impact For many building types and locations, an important question when designing and specifying the roof is, ‘How should I reduce or eliminate the impact of the solar radiation on the building’s cooling loads?’ This is because the sun is highest in altitude during the summer, and therefore the solar radiation on the roof is closest to perpendicular at times when the cooling loads are greatest
© Woodhead Publishing Limited, 2010
Roofing materials for thermal performance and environmental
465
(Fig. 19.4). When determining the heat gain (Watts) through a sunlit roof of thickness d, the temperature near the exterior surface is typically higher than the ambient air temperature and therefore the simple Q = (k∙A∙DT)/d) calculation, where DT is the temperature difference between inside and the ambient air, must be adjusted for radiant affects. This adjustment is often termed the sol-air temperature. In their book Mechanical and Electrical Equipment for Buildings, Stein and Reynolds define the sol-air temperature as ‘the higher temperature of outdoor air just above a roof surface that is produced by solar radiation (and radiation exchange with the sky)’ (Stein & Reynolds 2000). The simplified formula for roofs in SI units is:
te = to + aI/ho – 3.9 °C
19.1
where: te = sol-air temperature (°C), to = outdoor (ambient) air dry bulb temperature (°C), a = absorptance of surface for solar radiation, I = total radiation incident on surface (W/m2) and ho = coefficient of heat transfer by longwave radiation and convection at the roof surface, usually assumed to be = 17.0 W/m2 °K. te can be 50 °C (120 °F) for light to 70 °C (160 °F) or higher for dark absorptive surfaces. This is a primary reason for the development and growing popularity of cool roof materials.
19.3.2 The exterior weather-protection layer The exterior weather protection layer is most important for reducing the solair temperature. For residential construction with sloping roofs, fiberglass and asphalt composite shingles are very common. For low-slope (slopes less than 3/12 rise to run) non-residential construction, until recently asphalt or bitumen were often used as weather-protection layers. Asphalt-based materials 3500 3000 2500 2000 Half day horizontal radiation w/m
1500 1000 500 0
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
19.4 Half-day solar radiation intensities for 48o north latitude (source: ASHRAE 2005: table 8, ch. 27).
© Woodhead Publishing Limited, 2010
466
Materials for energy efficiency and thermal comfort in buildings
are rather inexpensive and easy to install although, due to their dark color and high solar absorptance, they result in high sol-air temperatures with correspondingly high cooling load impact. In non-residential construction, light colored stone, gravel or thin concrete pavers are often added as a topping layer to further protect from maintenance traffic while reducing the solar absorptance. These topping layers add both cost and weight to the roof system. Cool roof materials such as light colored polyvinyl chloride (PVC) have been developed and applied to reduce solar absorptance and the sol-air temperature. Cool roof materials may be classified as elastomeric, polyurethane, or acrylic, all of which have been shown to retain solar reflectance over time. The US Department of Energy’s Lawrence Berkeley National Laboratories found that the reflectance of cool coatings decrease by only 20% over the life of these products and that most of the decrease occurs in the first year after application (USDOE 2008). However, these roofing systems should be cleaned regularly to remove dirt that can accumulate and increase solar absorptance. Many roof system suppliers also offer cool roof coatings that can be spray-coated over asphalt built-up or bitumen systems, increasing solar reflectance while reportedly extending the life of these roofs. Some of these applied coatings have aluminum content to increase solar reflectance. Care should be taken when specifying aluminum-based roof coatings as these may increase solar reflectance but their low emittance may offset this benefit. The solar properties for the most common of cool roof materials and coatings are shown in Tables 19.2 to 19.8. Cool roofs are often applied as a layered membrane system in sheets with nominal dimensioning. Although not the focus of this chapter, it should be noted that roofs typically experience negative pressure and uplift as winds flow over the building. To prevent tearing and detachment of these membranes, many building codes, particularly in high wind and coastal zones, require either mechanical attachment (screws), or fully adhering (gluing) the membrane to the insulation or decking layer. The mechanical attachments often introduce thermal bridges into the roof assembly increasing heat transfer. Ballast such as stones, gravel and pavers are also used to hold the membrane in place, but with added weight and cost to the roof assembly. New technologies such as the omni-directional roof vent, shown in Fig. 19.5, take advantage of aerodynamic principles such as the Bernoulli principle and Venturi effect to create a low-pressure field under the membrane that counteracts the uplifting force without the need for attachments, adhesion or ballasting.
19.4
Vegetated roofing systems
The temperature profiles shown in Fig. 19.6 suggest that, when solar loads and space cooling are important issues, an alternative to conventional (asphalt)
© Woodhead Publishing Limited, 2010
Roofing materials for thermal performance and environmental
467
Table 19.2 Solar reflectance and thermal performance of asphalt shingles Product
Solar reflectance
Infrared emittance
Temperature rise (°C)
Solar reflect index
White ISP K-711 white ISP K-711 white Shasta white Generic white Generic grey Antique silver Aspen gray Ocean gray Gray Beachwood sand Light brown Med. lt. brown Medium brown Autumn brown Dark brown Green Surf green Onyx black Island brown Weathered wood Coral Saddle tan Desert tan Generic black Black
0.21 0.36 0.31 0.26 0.25 0.22 0.20 0.18 0.12 0.08 0.20 0.19 0.10 0.12 0.10 0.08 0.19 0.16 0.03 0.09 0.08 0.16 0.16 0.12 0.05 0.05
0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91
38 (68 F) 30.5 (55 F) 33 (59 F) 36 (64 F) 36 (64 F) 37 (67 F) 38 (69 F) 40 (71 F) 42 (76 F) 44 (79 F) 38 (69 F) 39 (70 F) 43 (77 F) 44 (79 F) 39 (70 F) 40 (72 F) 46 (83 F) 43 (78 F) 46 (83 F) 44 (78 F) 44 (79 F) 40 (72 F) 40 (72 F) 42 (76 F) 46 (82 F) 46 (82 F)
21 40 34 27 26 22 19 17 9 4 19 18 7 9 7 4 18 14 –2 6 4 14 14 9 1 1
or cool roof weather protection materials would be to introduce vegetation to the roof. Made popular through the roof garden designs of Frank Lloyd Wright and Le Corbusier, green roofs are now widely used in Europe and gaining popularity in North America. Green roofs can significantly lower the sol-air temperature due to the evapo-transpiration process that the planting medium undergoes. Evapo-transpiration is a complex process that depends on several factors such as type and density of the vegetation and ambient temperature and relative humidity. As shown in Fig. 19.6, due to this process temperatures for green roofs can be 16–22 °C (30–40 °F) lower than an asphalt or concrete roof. Green roofs are typically classified in one of three categories. Intensive green roofs, also called high profile or roof gardens, have growing medium depths generally exceeding 150 mm (6 inches). Intensive green roofs can be 300 mm (12 inches) or more in depth and usually require irrigation and drainage for the planting materials. Extensive green roofs are also called low-profile roofs, eco-roofs or performance roofs and have growing medium depths of less than 150 mm (6 inches). Extensive green roofs usually require
© Woodhead Publishing Limited, 2010
468
Materials for energy efficiency and thermal comfort in buildings
Table 19.3 Solar reflectance and thermal performance of roof coatings (white) Product Solar Infrared Temperature Solar reflectance emittance rise (°C) reflect index KoolSeal elastomeric on shingles Henry white coating on shingle Aged elastomeric on plywood Flex-tec elastomeric on shingles New insultec on wood, thick 0.5 mm Insultec on metal swatch Enerchron on metal swatch White coating (1 coat, 8 mils) White coating (2 coats, 20 mils) Triangle coatings, toughkote Triangle coatings, trilastic Triangle coatings, high reflectance 7 National coatings, acryshield Ultrecht acrylic, titanium white Guardcoat, white Koolseal elastomeric MCI, elastomeric Nexus/Visuron elastomeric White coating 1 (76.2 µm) White coating 1 (191 µm) White coating 1 (356 µm) White coating 1 (660 µm) White coating 2 (381 µm) White coating 2 (889 µm) White coating 2 (1143 µm) White coating 3 (152 µm) White coating 3 (254 µm) White coating 3 (304 µm) White coating 3 (381 µm) White coating 3 (686 µm) White coating 3 (1143 µm) White coating 4 (127 µm) White coating 4 (279 µm) White coating 4 (508 µm) White coating 4 (1143 µm)
0.71 0.71 0.73 0.65 0.84 0.78 0.77 0.80 0.85 0.85 0.83 0.84 0.83 0.83 0.74 0.81 0.80 0.85 0.60 0.72 0.77 0.79 0.81 0.81 0.82 0.68 0.75 0.78 0.77 0.80 0.80 0.68 0.78 0.80 0.80
0.91 0.90 0.86 0.89 0.89 0.90 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.90 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91
12 (22 13 (23 12 (21 16 (28 6 (10 9 (16 9 (17 8 (14 5 (9 5 (9 6 (11 6 (10 6 (11 6 (11 11 (20 7 (13 8 (14 5 (9 18 (33 12 (22 9 (17 8 (15 7 (13 7 (13 7 (12 14 (25 11 (19 9 (16 9 (17 8 (14 8 (14 14 (25 9 (16 8 (14 8 (14
F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F)
88 87 89 79 106 97 96 100 107 107 104 106 104 104 92 102 100 107 72 89 96 99 102 102 103 83 93 97 96 100 100 83 97 100 100
less maintenance than intensive systems and include small hardy plants and thick grasses. Due to their lighter weight and lower maintenance requirements extensive roofs are gaining popularity. In the United States, due to this increasing popularity, several roof system installers have developed a third modular classification with products that combine drainage, filtering, growing medium and vegetation layers, all installed in trays. These systems use modular block containers of anodized aluminum, polyethylene or recycled polystyrene and are easily transported, reducing installation time and effort.
© Woodhead Publishing Limited, 2010
Roofing materials for thermal performance and environmental
469
Table 19.4 Solar reflectance and thermal performance of roof coatings (tinted) Product Solar Infrared Temperature reflectance emittance rise (°C)
Solar reflect index
White coating (1 coat, 8 mils) White coating (2 coats, 20 mils) No pigment (1 coat, 18 mils) No pigment (2 coats, 36 mils) Raw cotton (1 coat, 8 mils) Raw cotton (2 coats, 26 mils) Gray goods (1 coat, 8 mils) Gray goods (2 coats, 18 mils) Desert Ridge (1 coat 14 mils) Desert Ridge (2 coats, 30 mils) Red pot (1 coat, 10 mils) Red pot (2 coats, 22 mils) Green gate (1 coat, 8 mils) Green gate (2 coats, 16 mils) Charcoal blue (1 coat, 16 mils) Charcoal blue (2 coats, 32 mils) White stucco (1 coat, 36 mils) White stucco (2 coats, 86 mils) Brown on wood shingle
100 107 40 64 92 99 45 45 40 40 14 16 13 14 9 9 72 82 22
0.80 0.85 0.36 0.54 0.74 0.79 0.40 0.40 0.36 0.36 0.16 0.17 0.15 0.16 0.12 0.12 0.60 0.67 0.22
0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.91 0.90
8 (14 5 (9 31 (55 21 (38 11 (20 8 (15 28 (51 28 (51 31 (55 31 (55 40 (72 40 (71 41 (73 40 (72 42 (76 42 (76 18 (33 14 (26 37 (67
F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F)
Table 19.5 Solar reflectance and thermal performance of roof coats (aluminum) Product Solar Infrared Temperature Solar reflectance emittance rise (°C) reflect index Aluminum Lomit on shingle Premium nonfibered on black Premium nonfibered on a rough surface Non-fibered on black Fibered on black Premium fibered on a rough surface Emulsion on a rough surface
0.61 0.54 0.56
0.25 0.42 0.41
27 (48 F) 28 (51 F) 27 (49 F)
50 46 48
0.55 0.52 0.40
0.42 0.44 0.56
28 (50 F) 29 (53 F) 35 (62 F)
47 43 30
0.37 0.30
0.58 0.67
36 (64 F) 38 (68 F)
26 21
Suppliers such as GreenTech have developed pre-manufactured green roof modular trays of 100% recycled polyethylene (Fig. 19.7). In her dissertation titled ‘A decision-making framework for vegetated roofing system selection’, Elizabeth Grant suggests that the design of green roofs involves assessment of six performance mandates (Grant 2007). These include: storm water management, energy consumption, acoustics, structure, compliance and codes, and cost. Green roof systems are reported to both reduce and delay the volume of rainwater runoff. For buildings with large
© Woodhead Publishing Limited, 2010
470
Materials for energy efficiency and thermal comfort in buildings
Table 19.6 General solar reflecting characteristics of roofing membranes Product Solar Infrared Temperature Solar reflectance emittance rise (°C) reflect index Gray EPDM White EPDM Black EPDM Hypalon T-EPDM Firestone SBS bitumen on white Smooth bitumen White granular surface bitumen Carlisle syntec system brite-ply Ecology roof Hypsam roofing systems, hyload Sarnafil beige Sarnafil blue Sarnafil white Stevens Hi-Tuff EP white Trocal roofing systems, white Trocal roofing systems, white Dark gravel on BUR roof Light gravel on BUR roof White-coated gravel on BUR roof
0.23 0.69 0.06 0.76 0.81 0.26 0.06 0.26 0.77 0.80 0.75 0.43 0.61 0.83 0.78 0.77 0.83 0.12 0.34 0.65
0.87 0.87 0.86 0.91 0.92 0.92 0.86 0.92 0.90 0.90 0.90 0.92 0.92 0.92 0.90 0.90 0.90 0.90 0.90 0.90
38 14 46 10 7 35 46 35 9 8 11 27 18 6 9 9 6 42 32 16
(68 (25 (83 (18 (13 (63 (83 (63 (17 (14 (19 (49 (32 (11 (16 (17 (11 (76 (57 (28
F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F) F)
21 84 –1 95 102 28 –1 28 96 100 93 49 73 104 97 96 104 9 37 79
Table 19.7 Solar reflecting characteristics of roofing tile Product Solar Infrared Temperature Solar reflectance emittance rise (°C) reflect index Red clay tile Red concrete tile Unpainted cement tile White concrete tile Concrete tile light beige coating Concrete tile light brown coating Concrete tile, pale bluish purple (mauve) Concrete tile pink & gray coating Concrete tile off-white coating Fiber cement earth brown Fiber cement, pewter gray
0.33 0.18 0.25 0.73 0.63 0.42 0.41
0.90 0.91 0.90 0.90 0.90 0.90 0.90
32 40 36 12 17 28 28
(58 (71 (65 (21 (30 (50 (51
F) F) F) F) F) F) F)
36 17 25 90 76 48 46
0.53 0.74 0.26 0.25
0.90 0.90 0.90 0.90
22 11 36 36
(40 (20 (64 (65
F) F) F) F)
63 92 27 25
roof areas this can be a significant factor in selecting a green roof system. Grant cites that annual water retention for green roofs ranges from 40 to over 90% of incident rainfall depending on system type and depth of growing medium (FLL 1998). The green roof for the Ford Motor production facility in Dearborn, Michigan by William McDonough and Partners was installed
© Woodhead Publishing Limited, 2010
Roofing materials for thermal performance and environmental
471
Table 19.8 Solar reflectance and thermal performance of metal roofing Product Solar Infrared Temperature Solar reflectance emittance rise (°C) reflect index New. Bare galvanized steel Aluminum MBCI siliconized polyester white Atlanta metal products kynar snow white
0.61 0.61 0.59
0.04 0.25 0.85
31 (55 F) 27 (48 F) 21 (37 F)
46 56 71
0.67
0.85
16 (28 F)
82
19.5 Schematic sectional view of a new omni-directional venturi roof vent for membrane applications.
in large part to offset the cost for on-site water retention and processing that would have been required if a conventional roof had been installed. Green roofs are reported to reduce energy consumption in buildings through added thermal mass and by lowering sol-air temperatures. As previously introduced, the lower sol-air temperatures are primarily due to the evapotranspiration of the plant media. For any given project the energy savings benefits will depend on a variety of factors including climate, building function
© Woodhead Publishing Limited, 2010
472
Materials for energy efficiency and thermal comfort in buildings Surface 1. Black asphalt 2. Long grass Outdoor air 120
100
Temperature (°F)
80
60
40
20
0
j f m a m j j a s o n d Month Monthly surface temperatures Material
Surface temp. (°F)
Dev. from air
Dark Asphalt Light Asphalt (dirty) Concrete Short grass (1–2 inches) Bare ground Tall grass (36 inches)
124 112 108 104 100 96
+ + + + + +
40 28 24 20 16 12
19.6 Horizontal surface temperatures for various sunlit materials (source: Watson 1993).
and internal loads, and selection of the other roof components. The energy savings may range from only marginal when compared to buildings with concrete roof decks (thermal mass) and a highly reflective cool roof membrane in temperate or cool climates, to significant savings when compared to low
© Woodhead Publishing Limited, 2010
Roofing materials for thermal performance and environmental Introducing the greentech system module
473
Optional fold up fence or custom sleeve for increased or varying depths
Locator pad
Drainage and ventilation
Perforated base
Fork lift accessible channels (all 4 sides) 100% post industrial recycled polyethylene
19.7 GreenTech Inc. polyethylene modular green roof trays (source: GreenTech 2008).
mass roofs in predominantly cooling load-dominated buildings in moderate to hot climates. The application of green roofs should include a careful life cycle cost analysis using energy modelers such as EnergyPlus that include algorithms that model the evapo-transpiration process from green roofs. Simulation studies conducted for an institutional building for a temperate mid-Atlantic US location suggested that the energy savings from a green roof were small when compared to a typical high mass concrete roof with a cool roof membrane (Dhamne 2008). As suggested by Grant, when considering a green roof, two additional performance mandates should be taken into account: impact on the structural system and cost. Green roofs are typically additive systems where a drainage layer, filter fabric, growing medium and plant material are added to the decking, insulation and weather-protection layers. Green roofs can add from 54 to 980 kg/m2 (11–200 psf) dead (self-weight) and live load (when saturated with water) to the roof system and $110–$220 per square meter ($10–$20 per square foot) in cost. However, when considering the green roof system, the decision to implement or not should be one based on a holistic view. The green roof is a system that can have both direct and indirect benefits. For example due to their relatively low surface temperatures, green roofs can reduce the urban heat island effect. This is part of the reason why cities such as Chicago, IL and Portland, OR have adopted incentive programs to encourage the installation of green roof systems. In addition to reducing
© Woodhead Publishing Limited, 2010
474
Materials for energy efficiency and thermal comfort in buildings
rainwater runoff, the green roof for the Ford plant in Dearborn, MI provided a habitat for nesting birds in the region. Although difficult to quantify, these benefits should be considered as part of the decision-making process.
19.5
Solar integrated roofing systems
The question of how the building meets the sky might suggest opportunities for active solar collection to meet either electrical or thermal needs in the building. Depending on latitude, the roof typically has greater year-round solar collection potential per square meter than vertical walls. As a general rule-of-thumb for year-round collection, the tilt angle of the roof from the horizontal should be approximately equal to the altitude angle of the sun for noon on December 21, for the location in question. For greater heating season collection, the angle should be the altitude + 15° (more vertical) and for cooling season collection altitude – 15°. These angles are general for early design development and should be refined through a more rigorous analysis to determine the optimum tilt angle. Tools for early design analysis and cost versus savings assessment are available at the US National Renewable Energy Labs website (PVWatts 2008). As previously shown, the British Pavilion for Expo ’92 is an expressive example of photovoltaic panels being considered as part of the roof system. For electrical production, photovoltaic manufacturers such as UniSolar Inc. have integrated their products directly into roofing materials (Fig. 19.8). The PVL-68, PVL-124 and PVL-136 flexible PV panels are 394 mm (15.5 inches) wide which can fit neatly between seams of standing-seam galvalum metal roofs (Uni-Solar 2008). Similarly UniSolar and HelioVolt Inc. in cooperation with roofing suppliers such as Acrylife Inc. are exploring the integration of photovoltaic panels directly into membrane roof systems during the manufacturing process. This has the potential to reduce the cost and installation time of the PV-integrated roof system while increasing life and durability. For the residential market, suppliers such as OkSolar (OkSolar 2008) have roof shingles with integrated PV that are easily applied to wood frame construction. While the above products typically use thin-film PV cells that have lower efficiencies when compared to crystalline or poly-crystalline technologies, recently developed thin-film PV products are quickly closing the gap for efficiency, making these systems more economically feasible. Also when designing a PV-integrated roof, care should be taken to simultaneously consider collector size and inverter capacity, as invertors are available in incremental sizes that should be matched with the collector. While the economic benefits of PV-integrated roofs vary from location to location and will depend on factors such as electrical demand and the local utility rate structure, with increasing manufacturing efficiencies and economies of scale, these products are likely to continue to gain popularity.
© Woodhead Publishing Limited, 2010
Roofing materials for thermal performance and environmental
475
SmartchargeFLXTM
Model flx-5
19.8 UniSolar Inc. PV integrated roof system (source: Uni-Solar 2008).
For locations where incident solar radiation may be effectively harnessed, integrated thermal solar roof systems should be considered for both residential and non-residential buildings. Systems such as the rooftop air collector for an apartment block in Gothenburg Sweden by Christer Nordstrom, or the Orange Mode (OM) Solar roof, have been applied in Japan and Europe and are now being used in the United States for homes, schools and light commercial buildings. These systems act as a double envelope with a ventilated cavity between the solar collecting exterior layer and the insulating inner layer. (Fig. 19.9) (OM Solar 2001). Air flowing through the ventilated cavity absorbs heat which can be collected at the roof ridge and used for either space heating or transferred through a heat exchanger for pre-heating domestic hot water. In addition, the ventilated cavity can be used to collect and remove roof solar gains during overheated periods, thus reducing cooling loads. Solar integrated roof systems such as this can be economically viable when compared to additive thermal solar systems but attention should be given to construction quality as air leaks can degrade the benefits of the system. Also sensing and control for backflow prevention may be needed to prevent condensation inside the cavity. Studies of a full scale assembly on the campus of Virginia Tech (temperate climate zone) showed that over 60% of the annual space heating needs could be met with this system as
© Woodhead Publishing Limited, 2010
476
Materials for energy efficiency and thermal comfort in buildings Heat collection/ glass panels
Photovoltaic panels Roof duct
Heat collection/ sheet-metal roofing
Air inlet
Roof air flow channel
19.9 Schematic view of OM Solar thermal solar integrated roof system (source: OM Solar 2001).
the roof of a typical residential building (Xu 2004). SolarWall Inc. indicates that annual energy savings from a similar wall integrated system may range from 681392 KJ/m2 yr to 2,725,567 KJ/m2 yr in the continental US (Fig. 19.10) (SolarWall 2008).
19.6
Natural ventilation
As introduced in Chapter 3 natural ventilation is a design strategy that can both reduce energy consumption and provide occupants with a positive psycho-physical connection between inside and out. When designing buildings for natural ventilation, the design of the roof can play a significant role in the ventilation strategy. Bernoulli’s principle indicates that as wind speed increases, pressure will decrease. Because of this, as wind flows over a building, it typically accelerates producing a low pressure uplifting force. This is why roofs often fail during high wind events such as hurricanes. This condition may be enhanced by moderately sloping the roof while smoothly compressing and accelerating the airflow on the windward surface of the roof and near the ridge. Utilization of the Bernoulli principle through the design of the roof can lead to solutions that intentionally create low pressure conditions to draw stale air out of the building. By analyzing wind speed and direction, and orienting the roof slope into the prevailing winds during periods when natural ventilation is appropriate, properly located roof openings can draw air out of the building. Figure 19.11 shows a proposed design of a
© Woodhead Publishing Limited, 2010
Roofing materials for thermal performance and environmental
477
Ventilation preheat energy savings 180 120
180
180
240 120 120
60 KBtu/ft2/yr 240–300 180–240 120–180 60–120 0–60
60
120 120
60
19.10 Estimated annual energy savings from the integration of a SolarWall enclosure system (source: SolarWall 2008).
19.11 Image of a proposed naturally ventilated middle school for Blacksburg, VA (source: Henderson 1999).
middle school for Blacksburg, VA where wind tunnel studies indicated that the sloping roof could serve the natural ventilation strategy. In this building wind is compressed and accelerated over the moderately sloped roof creating a low pressure zone at the top of the corridor/atrium (Henderson 1999). This low pressure draws outdoor air through the adjacent classrooms and out of the building. Similarly Thomas Herzog’s Hall 26 was designed with a wave-form roof that compresses and accelerates the wind flowing over the building to create a low pressure region that draws air out of openings
© Woodhead Publishing Limited, 2010
478
Materials for energy efficiency and thermal comfort in buildings
near the ridge of the roof. In both designs the roofs speak to their role in the natural ventilation system. A special case of Bernoulli’s principle is shown in Fig. 19.11 where air is smoothly compressed through an opening with increased air speed and lower pressure. Termed the Venturi effect, this condition can be taken advantage of for the design of roofs for natural ventilation. The image in Fig. 19.11 is for the proposed design of a middle school that includes a roof section with an upper inverted aerofoil element supported above a convex lower element. As the prevailing winds smoothly compress through this roof element, low pressure is created. By coupling this low pressure to the building’s interior, outward airflow will be induced. Similar roof designs are employed in the Ionica building in Cambridge UK by RH Partnership as shown in Fig. 19.12(a) (Jones 1998: 80) and the RWE Ag building by Overdick and Partners in Essen, Germany (Fig. 19.12(b)) to achieve natural ventilation (Jones 1998: 217). In the Ionica building, inverted pyramids are raised above the top of the central atrium to create the low pressure condition and draw air up and out of the building. In the RWE building, an inverted aerofoil disk is lifted above the top floor to compress and accelerate the wind to induce upward air flow out of the central ventilation shaft of the building. In all of these buildings the roof not only plays an important role in the natural ventilation strategy but becomes a visual expression of environmental response.
19.7
Rainwater harvesting
In addition to solar control and active collection, and natural ventilation, the roof has at least one other opportunity for environmental expression. For many regions of the world, including an increasing area of the United States, consumption and depletion of fresh water has become a serious environmental concern. As a result, programs such as the US Green Building Council’s Leadership in Energy and Environmental Design (LEED) (USGBC 2008) provide credits for architectural design strategies such as rainwater harvesting that aim to reduce off-site water consumption. For these systems the roof is the primary building enclosure element for collecting and possibly filtering, in the case of a green roof, the incidental rainfall. The design procedure for rainwater harvesting includes: basic planning (defining the roles between building and water use), estimating need (rates of consumption), estimating collection potential, and system detailing. The steps are summarized in depth in Stein & Reynolds 2000: ch. 9) and will not be repeated here. Average annual and monthly rainfall rates for estimating collection can be found through use of tools such as the Climate Consultant software available at http://www.aud.ucal.edu/energy-design-tools. One note should be made for applying the procedures for estimating rainwater collection: the roof area to be used is the projected horizontal area. For flat roofs this will be the
© Woodhead Publishing Limited, 2010
Roofing materials for thermal performance and environmental
479
(a)
(b)
19.12 (a) Ionica Building (Jones 1998: 80) and (b) RWE Ag Building (Jones 1998: 217) utilizing roof elements to create a low pressure region to draw stale air out of each building.
actual roof area, but for sloping roofs the projected area will be less than the actual roof area. Figure 19.13 shows a design for a small two-room environmental learning center to be located in Southwest Virginia, US. In this design the roof and rainwater collection cistern act together to provide students with an opportunity
© Woodhead Publishing Limited, 2010
480
Materials for energy efficiency and thermal comfort in buildings
Cistem 0 5°
15°
N
Cistem
Area: 3475 sf
19.13 Plan (down) and section (up) of a small middle school designed to celebrate rainwater harvesting.
to observe and celebrate the rain and its collection. In this way the roof participates in the learning experience while expressing its environmentally responsive role within the building’s design.
19.8
The role of roofs in building rating systems
During the past several years building rating systems such as BREEAM and BEPAC have been developed and adopted to promote sustainability and environmental design. As an adaptation of these systems to the US building market, the US Green Building Council has developed and promoted the Leadership in Energy & Environmental Design (LEED) system to define and measure ‘green buildings’. The LEED system has four certification levels, Certified, Silver, Gold and Platinum, as an indicator for the level of environmental responsiveness. While the LEED rating system addresses a very wide range of design issues ranging from the site to stormwater management, and commissioning and construction management, it should be recognized that the roof can play a significant role in achieving a desirable rating. In the LEED rating system the roof can contribute to several points toward the 69 maximum rating. For example, as previously shown, a vegetated roof
© Woodhead Publishing Limited, 2010
Roofing materials for thermal performance and environmental
481
can reduce rainwater runoff resulting in credit for stormwater management. Due to evapo-transpiration and the lower sol-air temperatures of vegetated roofs, credit can be taken for landscaping and exterior design to reduce heat islands. The use of the roof as a rainwater harvesting system can contribute to water use reduction, while the integration of active solar or photovoltaic sub-systems might be applied to minimum energy performance, renewable energy, and innovation in design credits. Through the integration of skylights, clearstory windows or a glass-covered atrium, the roof can be an aperture for daylight and views while providing a positive biophilia connection between inside and out. It should be recognized that the roof plays an important role in achieving LEED rating.
19.9
Conclusions
Choices for construction technique and materials play an important role in the performance of roof systems. The design of the roof should consider construction approaches such as hollow-core concrete planks that allow for both assembly and disassembly, and re-use, while roofing materials such as bio-composites can reduce the volume of building-related waste. Often the roof is the most important building enclosure component when considering energy consumption and solar control. The solar impact on the roof is often very significant as the air temperature near a dark colored sunlit roof can be several degrees higher than the ambient air. Light reflecting ‘cool’ roof materials are gaining popularity because of their lower sol-air temperatures when compared to conventional dark asphalt or bitumen roofs. In part for their lower surface temperatures due to evapo-transpiration, vegetated green roofs are also gaining popularity as an energy conservation system. Green roofs can also be applied as a rainwater management strategy while offering the added benefit of reducing the heat island effect in urban applications. Because of these and other potential benefits, the roof can account for several points in building rating systems such as LEED. Systems integration should also be a part of the design strategy as active solar and photovoltaics can often be cost effectively merged with the roof system, particularly when using new roofing products that combine roof subsystems with these environmental components. When properly oriented to prevailing breezes and sloped to create low pressure conditions, the roof can be an active participant in natural ventilation strategies. And, finally, the roof is typically the largest surface to receive rainfall and consequently should be considered as part of a rainwater harvesting system. We should view the roof as a design opportunity: an opportunity for expression of environmental responsiveness through solar collection and control, natural ventilation and/ or rainwater harvesting. We should ask: How should the building meet the sky?
© Woodhead Publishing Limited, 2010
482
Materials for energy efficiency and thermal comfort in buildings
19.10 References ASHRAE 1989, ASHRAE/IESNA 90.1-1989 ASHRAE Standard: Energy Efficient Design of New Buildings Except Low-Rise Residential Buildings, ASHRAE, Atlanta, GA. Table 8A. ASHRAE 2005. ASHRAE Handbook: Fundamentals, The American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. Atlanta, GA. Table 4, pg. 25.5. Brown, G.Z. & DeKay, M. 2001, Sun, Wind and Light – Architectural Design Strategies, Second edition, John Wiley & Sons Inc., New York, pp. 214–217. Buchanan, P. 2000, Renzo Piano Building Workshop – Complete works, Phaidon Press Limited, London. CIMA 2008, Cellulose Insulation Manufacturers Association, http://www.cellulose.org/ CIMA/ Composite Technology Park 2008, http://www.compositestechnologypark.com/ Dhamne, C. 2008, ‘Energy Consumption Comparison for an Institutional Building located in Southwest Virginia with an “Extensive Green Roof System”’, College of Architecture and Urban Studies, Virginia Tech., Blacksburg, VA. Environ Bio-composites 2008, http://www.environbiocomposites.com/ Forschungsgesellschaft Landschaftsentwickling Landschaftsbau e. V. (FLL) 1998, Bewertung von Dachbegrunung. Empfehlungen sur Bewertung in der Bauleitplanung, bei der Baugenehmigung und bei der Bauabnahme. Bonn: FLL. Grant, E. 2007, A decision-making framework for vegetated roofing system selection, Doctoral dissertation, College of Architecture and Urban Studies, Virginia Tech., Blacksburg, VA. GreenTech 2008, http://www.greentechitm.com/systems/roof.asp. Henderson, James, 1999, Architecture for the imagination: a study of an elementary education environment, Graduate Thesis, College of Architecture and Urban Studies, Virginia Tech., Blacksburg, VA. Humm, O. & Toggweiler, P. 1993, Photovoltaics in Architecture, Birkhauser Verlag, Berlin. Jones, D. L. 1998, Architecture and the Environment – Bioclimatic Building Design, The Overlook Press, Woodstock, NY. Model Energy Code 2000, The International Energy Conservation Code 2000, The International Code Council. Oak Ridge National Laboratory 2003, R30/30 Roofing systems, http://www.ornl.gov/sci/ roofs+walls/research/R30.htm, 5 Nov. 2003. OkSolar 2008, OkSolar Inc. Photovoltaic integrated roof shingles. http://www.oksolar. com/roof/ OM Solar 2001, The Orange Mode. The OM Solar Association Inc., Sausalito, CA. PVWatts 2008, National Renewable Energy Laboratory Photovoltaic Calculator. http:// rredc.nrel.gov/solar/codes_algs/PVWATTS/ Roofhelp.com 2008, http://www.roofhelp.com/ventilation2.htm. SolarWall 2008, SolarWall Inc. – Solar integrated wall systems. http://solarwall.com/ en/home.php Stein, B. & Reynolds, J. S. 2000, Mechanical and Electrical Equipment for Buildings, 9th edn, John Wiley & Sons Inc., New York, pp. 135–136. Uni-Solar 2008, United Solar Ovonic Inc. Photovoltaic Integrated roof membranes, http:// www.uni-solar.com/ US Department of Energy, Lawrence Berkeley Laboratories 2008, http://eetd.lbl.gov/ coolroof/coating.htm © Woodhead Publishing Limited, 2010
Roofing materials for thermal performance and environmental
483
USGBC 2008, US Green Building Council – Leadership in Energy and environmental Design, http://www.usgbc.org/DisplayPage.aspx?CMSPageID=222 Watson, D. 1993, The Energy Design Handbook, The American Institute of Architects, Washington, DC, p. 38. Xu, Z. 2004, Experimental study to determine the energy efficiency of an integrated solar thermal roof system, Master of Science Thesis, College of Architecture and Urban Studies, Virginia Tech., Blacksburg, VA.
© Woodhead Publishing Limited, 2010
20
Assessing and benchmarking the performance of advanced building façades
J. A. C l a r k e and C. M. J o h n s t o n e, University of Strathclyde, UK
Abstract: This chapter describes the energy demand reshaping and supply technologies that may be encapsulated within an advanced building façade. Laboratory testing techniques for the characterisation of the parameters underlying each technology are elaborated as the essential prerequisite of integrated performance appraisals of specific technology combinations in a façade design context. Based on the results from simulations undertaken in the UK climate context, performance benchmarks are suggested for some principal façade configurations. Key words: advanced façades, demand reduction, renewable supply, integrated performance assessment, performance benchmarks.
20.1
Advanced façades
In support of the deployment of urban-scale new and renewable energy systems, attention is being directed to the energy demand–supply interface within the urban context in an attempt to enhance the temporal match. Whatever approach is taken, it is likely that demand profile reshaping will be as important as overall demand reduction because the former can facilitate the integration of energy sources that are both intermittent and stochastic. Advanced façades (Selkowitz et al. 2003) can play a significant role in this regard because of the potential to blend technical systems that affect both energy demand and local supply. However, designers of such façades are then confronted by three significant issues: how to characterise the performance of specific technologies, how to evaluate the performance impacts when technologies are combined within a given façade, and how to judge the outcome in terms of overall cost-effectiveness. This chapter describes laboratory approaches that may be used to address the first issue, and an integrated simulation approach that addresses the second. The third issue is not addressed here. Examples of advanced façades that incorporate innovative components are then presented and, from the outcome, performance data are extracted that may be used to benchmark advanced façade designs.
484 © Woodhead Publishing Limited, 2010
Assessing and benchmarking the performance
20.2
485
Façade component options
There are several existing technologies that may be integrated within an advanced façade and these can be conveniently categorised into those that reshape/reduce demand and those that supply heat and power from locally deployed heat and power generating components.
20.2.1 Demand reshaping Several options exist to reshape/reduce energy demand. Basic insulation and capacity can be enhanced to an optimum level beyond which the law of diminishing returns will apply. Concepts such as breathable (Imbabi and Peacock 2004) and transparent (Wittwer and Platzer 2000) insulation can be adopted whereby heat loss reduction is enhanced: in the former case, by utilising the solar energy contained in the surface boundary layer; in the latter case, by allowing the deep transmission of the incident solar flux. Advanced glazings (Hutchins 1998) can be employed to change demand through switchable properties (thermo-, photo- and electro-chromic coatings), heat loss reduction (low emissivity coatings and low conductivity interpane gas), light redirection (prismatic coatings and attached light shelves) or integrated mechanical devices (shading devices and shutters). Double envelopes (Loncour et al. 2004) can also be introduced to provide solar ventilation, air pre-heating and/or passive cooling in addition to lowered thermal transmission and daylight control.
20.2.2 Energy supply Several technologies can be integrated within the façade to provide thermal and electrical energy from renewable sources. Photovoltaic cells (IEA 2002) can be deployed to convert the solar flux to electrical power and, where used in hybrid mode, to also produce heat (this mode of operation has the added advantage in the case of crystalline cells of reducing cell temperature and so maintaining optimum energy conversion efficiency). Advanced glazings can also be used to enhance/control the penetration of daylight to the interior; a photocell-based control system may then be deployed to regulate artificial lighting use in a complementary manner in order to displace the consumption of high grade electricity. Ducted wind turbines (Grant et al. 2008) can be deployed at the roof junction to produce electrical power by reducing the pressure at the leeward side of the duct through the action of an integrated spoiler, thereby enhancing inward air flow at the windward side. Where a double façade is employed, the solar chimney effect can be used to enhance the air flow at turbine entry. Just as the technology deployment options are many, so are the conflicts
© Woodhead Publishing Limited, 2010
486
Materials for energy efficiency and thermal comfort in buildings
that can arise because of the interactions between technologies when deployed in various combinations. The core issue addressed in this chapter is ‘how can the multivariate impacts of alternative deployment combinations be assessed at the design stage in order to inform decision-making that respects the implicit performance trade-offs?’. For example, will a photovoltaic façade harvesting renewable solar power to provide electricity give rise to a more cost-effective solution than (mutually exclusive) daylight capture devices deployed as a means to reduce electricity usage?
20.3
Performance models and model parameter measurement
Building performance simulators operate in the transient domain based on models of material and component behaviour that require a range of fundamental parameters determined by experimental means. In order to facilitate integrated performance assessment and benchmarking, it is therefore necessary to decide on suitable prediction models and establish representative values for their related input parameters. For example, breathable insulation might be represented by a conduction model that employs an equivalent overall conductivity, which needs to be identified before the model can be used. Alternatively, a more refined model might be employed that differentiates between conductive and convective heat transfer and so requires values for the parameters relating to these distinct mechanisms. For complete systems, such as photovoltaic components, quoted performance is often related to a standard test condition and the underlying model serves to translate performance to the non-standard conditions encountered throughout a simulation. Models and experimental methods exist for each of the demand/supply technologies mentioned in the previous section and these are summarised here.
20.3.1 Material properties The position of some materials within an advanced façade, such as insulation, will ensure that they operate in the dry state. For this case, the measurement of conductivity is carried out by either the guarded hot-plate or heat flow meter technique. The former has an accuracy of around ±3%. The latter apparatus is simpler to use but requires the availability of calibration samples measured by the hot-plate method so that the overall error may be around twice that of the hot-plate method. Where a material operates in the moist state, the measurement of conductivity is problematic because the application of a temperature difference to a moist specimen results in a moisture gradient, causing moisture to migrate from the higher temperature. At constant applied temperature difference, the same sample will have different moisture gradients for different moisture contents
© Woodhead Publishing Limited, 2010
Assessing and benchmarking the performance
487
while, at constant moisture content, the same sample will have different moisture gradients for different applied temperatures. Furthermore, as the moisture content increases, condensate will appear at the cold side of the specimen implying that the measured conductivity will increasingly fall below the conductivity for a linear moisture distribution with increasing moisture content. In the absence of knowledge of the moisture gradient, quoting applied temperatures at constant moisture content does not uniquely define the conductivity measurement. Instead, measurements become particular functions of temperature, moisture content, sample thickness, sample orientation (upor downward heat flow) and length of measurement period. The thin-heater thermal conductivity apparatus uses a low applied temperature difference to reduce the problem of moisture migration. With regard to specific heat capacity, the seemingly straightforward definition of this parameter as the amount of heat energy required to be added or removed to change unit weight of a material by unit temperature belies the difficulty of measurement. One difficulty, particularly for materials of low conductivity, is that it is difficult to input or extract heat quickly, making the design of accurate practical experimental apparatus difficult. Test techniques include conventional absolute calometric methods and indirect dynamic methods based on Fourier’s equation and regression analysis applied to test results. Because of the high specific heat capacity of water, the effect of moisture content on the specific heat of a material is significant and must be taken into account. In principle, the overall specific heat capacity of a material is the linear addition of that of the dry material to that due to the amount of water present. In practice, this requires knowledge of the in-use moisture content. While calculations can be based on standard design values, the absence of a practical, non-destructive test method for determining on-site moisture content gives rise to an inherent uncertainty in calculating values of specific heat capacity for moisture containing materials. This uncertainty is compounded when it is realised that it is the volume heat capacity (i.e. the product of density and specific heat capacity) that is important in determining thermal capacity. Hence, the uncertainty in density is added to the uncertainty in specific heat capacity for volume heat capacity. A further source of error will arise from the fact that conditions are dynamic in practice. In general, materials will be subject internally to temperature and moisture gradients that do not correspond to equilibrium distributions. Hence, both the thermal resistivity and capacity will vary within the material. It is also the case that the specific heat capacity is a function of temperature. However, given the relatively small range of temperature involved in calculating the hygrothermal performance of buildings, the error associated with adopting a single figure value will be insignificant compared to the scale of error from other causes.
© Woodhead Publishing Limited, 2010
488
Materials for energy efficiency and thermal comfort in buildings
Glazing materials have the added property of transmissivity in addition to those of reflectivity and absorptivity. As the sum of the three properties must equal unity, it is only necessary to measure two properties. Glazing manufacturers publish basic data on the solar optical properties of various forms of sheet glass and transparent plastic materials, and modelling systems are available that provide optical data as a function of flux angle of incidence and specific window configuration (e.g. Window 5.2 available from http:// windows.lbl.gov/software/window). Other material properties required to support the integrated modelling process include opaque surface emissivity, absorptivity and reflectivity as required for radiation modelling within the longwave, shortwave and visible portions of the electromagnetic spectrum, respectively.
20.3.2 Transparent insulation Transparent insulation (TI) allows solar energy to be transferred to an intrafaçade location where a material of suitable thermal capacity is located and used to effect amplitude dampening and time delay. While the angular shortwave transmittance may be determined as above, a new issue arises: the possible degradation in performance where encapsulation is not air tight and penetrating air flow can deposit dust particles within the TI honeycomb structure resulting in surface staining. In this case, the impact on angular shortwave transmissivity can be established experimentally as shown in Fig. 20.1.
20.3.3 Advanced glazings Advanced glazings provide regulation of energy flow via devices such as multiple panes, inter-pane inert gas filling or vacuum, low emissivity or spectrally selective coatings, optical manipulation (diffusing, re-directing), variable transmissivity, and encapsulated shading. An important factor when adopting advanced glazing is to ensure that the framing does not allow thermal bridges that will compromise overall system performance. The detailed modelling of the impact of advanced glazings on internal illuminance distribution and glare under different sky conditions depends on the characterisation of transparent and translucent materials (diffusing and non-diffusing) in terms of their response when illuminated by point and diffuse light sources. This requires the measurement of window normal–normal transmittance (for use with point sources such as the direct solar beam) and hemispherical–hemispherical transmittance (for use with diffusing sources such as the sky). Internal surface finishes also need to be characterised in terms of their reflectance, which will depend on incident angle in the case of specular surfaces.
© Woodhead Publishing Limited, 2010
Assessing and benchmarking the performance
489
0.7 0.6
Clean Stained
Transmissivity (–)
0.5 0.4 0.3 0.2 0.1 0
0
10 20 30 40 50 60 Solar incidence angle (degrees from surface normal)
70
20.1 Impact of staining on TI shortwave transmissivity.
Lights
Small power Rotational loads
Public Heat recovery electricity supply
Glass back sheet
PV layer Resin
Local PV power utilisation
To building Glass cover Hybrid PV façade
PV component
20.2 A façade-integrated PV component with local power use.
20.3.4 Photovoltaic cells In accordance with European recommendations, manufacturers test their photovoltaic (PV) products under ESTI Test Specification Number 503. In such a test, a module’s performance is characterised within an environment where the cell temperatures are maintained at 25 °C and the module is exposed to a pulsed irradiance of 1000 W/m2. From this test, the current and voltage characteristics are recorded to allow the open circuit voltage, short circuit current, and maximum power point voltage/current to be quantified. Consider Fig. 20.2, which shows a façade-integrated PV component generating
© Woodhead Publishing Limited, 2010
490
Materials for energy efficiency and thermal comfort in buildings
electricity and heat; the former delivered to the building’s distribution network, the latter to a heat recovery system. solar radiation is transmitted to the surface of the PV layer through the glass cover. A portion of this flux will be converted to electrical energy: ai = a¢i + qe where ai is the irradiation of the PV layer, a¢i the solar radiation absorbed by the PV layer that is converted to heat and qe the electrical power output. Models exist for the calculation of qe, such as the one by Buresch (1983): È ˘ Ê ˆ e.V qe = n.c.p. ÍV.I V.I d Á exp – 1˜ – V.I l ˙ s . d. q Ë ¯ Î ˚ where q is the temperature (k) of the PV material, V the voltage at maximum power point, Id the diode current, Il the light generated current, d the diode factor, n the number of series connected cells, c the number of parallel connected cells, p the number of surface panels, e the electron charge (1.6 ¥ 10–19 Coulombs), and s the stefan–Boltzmann constant (1.38 ¥ 10–23 W/ m2k4). the diode factor and current are given by d=
e(V – Voc ) Ê I sc – I mp ˆ n.a .q stc log Á Ë I sc ˜¯ q –q ref
I sc 2 l Id = Voc Ê e.V ˆ c.exp Á – 1˜ Ë n.k.d.qstc ¯ and the light generated current by Il =
a ¢I sc c.a stc ¢
where l is an empirical factor and qstc, Voc, Isc, Imp and a¢stc are temperature, open circuit voltage, short circuit current, maximum power point current and cell insolation under standard test conditions, respectively. these are the parameters that need to be measured in a laboratory test.
20.3.5 Ducted wind turbines Ideas for wind energy conversion in an urban environment have ranged from the notion of placing wind turbines on roofs, to façade-integrated ducted
© Woodhead Publishing Limited, 2010
Assessing and benchmarking the performance
491
wind turbines. With reference to Fig. 20.3, when the wind blows at right angles to a tall façade, stagnation will occur at about two-thirds of the total height. Below this level a rolling vortex is formed, above it the air rises to pass over the roof. If the roof is flat, it will separate from the upwind edge, possibly reattaching some distance downstream. A ducted wind turbine (DWt; Grant et al. 2008) is designed to draw air from the high-pressure region on the upwind face of the building and exhaust it into the low-pressure region above the flat roof. The device will operate efficiently over a 60° range of wind directions, with the ducting serving to dampen any turbulence in the air stream, which can be a serious problem when other buildings are in close proximity. the power output, Pw, from a conventional wind turbine may be determined from Pw = 0.5Cp rpR2v2 where v is the wind speed (m/s), R the rotor radius (m), r the air density (kg/m3) and Cp a power coefficient that represents the effectiveness of the turbine rotor. For a given turbine, Cp is a function of the tip speed ratio ts: ts = w R n where w is the angular velocity of the rotor. Photovoltaic panel Negative pressure coefficient
Rotor Positive pressure coefficient Generator
Building face
20.3 A façade-integrated ducted wind turbine.
© Woodhead Publishing Limited, 2010
492
Materials for energy efficiency and thermal comfort in buildings
Because most conventional grid-connected wind turbines are constrained to turn at constant angular velocity, as the wind speed varies, the value of ts (and hence Cp) will change. A DWt, being a small unit for autonomous use, is unlikely to be connected to the electrical grid and so can operate in variable-speed mode. Maintaining a constant value for ts allows the DWt to operate at a constant and optimum value of Cp. Combining the previous two equations gives: Pw = tw =
0.5Cp rp R 2w R = Kw 3 ts3
where K is a constant and the torque t at the rotor shaft follows a quadratic characteristic, t = Kw2. In practice, it is possible to control the generator to produce a quadratic torque characteristic at the rotor shaft, and so a near-constant value of Cp may be achieved. this mode of operation can be abandoned in high wind speeds, where it is necessary to limit the power produced. here, the electrical load on the generator may be increased, reducing the rotor speed, stalling its blades and reducing Cp to the required value. At low wind speeds, say below 5 m/s, the power output will fall as a result of disproportionate mechanical losses and low generator efficiency. Wind tunnel tests may be used to characterise the change in Cp over the operational range: Fig. 20.4 shows measured power output, Pm, and Cp against wind speed from such a test. the variation in Cp is determined from
70
Power (W)
0.4
Power Power coefficient (Cp)
0.35
60
0.3
50
0.25
40
0.2
30
0.15
20
0.1
10
0.05
Cp
80
0
0 0
2
4
6
8 10 12 Wind speed (m/s)
14
16
18
20.4 Monitored power output and Cp value for a ducted wind turbine.
© Woodhead Publishing Limited, 2010
Assessing and benchmarking the performance
493
Pm Pi where Pi is the ideal power output given by Pi = 0.5 rAv3 where r is the air density, A the swept rotor area and v the wind speed.
20.3.6 In situ measurements laboratory testing under standard conditions will be inappropriate where material properties are expected to operate under significantly different conditions in practice. For these cases, in situ testing will be required. A heat flux sensor – a transducer that generates a signal that is proportional to the local heat flux – may be employed to determine the mean value of thermal conductivity of a construction over a given period. typically the sensor would be embedded within a substrate with a high thermal capacity to minimise the dynamic errors associated with short time constant materials: Figure 20.5 shows a sensor embedded within a concrete construction block. In this way, the one-dimensional heat flow rate can be determined and used to calculate the effective thermal conductivity, k, as a function of the timeaveraged temperature difference: k = Qx/Dt where Q is the integrated heat flux (W/m2), Dt the time-averaged temperature difference across the material (k) and x the material thickness (m). the techniques of pyrometry and photometry may be used to measure, by non-contact means, longwave emissivity and solar optical properties respectively. A pyrometer focuses thermal radiation, qt, onto a detector,
20.5 Heat flux sensor embedded within a high density concrete block.
© Woodhead Publishing Limited, 2010
494
Materials for energy efficiency and thermal comfort in buildings
allowing the determination of the surface temperature, qs, from the Stefan– Boltzmann law:
qt = seqs4
where s is a constant and e the known surface emissivity; if the surface temperature is known, its emissivity can be inferred. Photometry measurements require lux meters to quantify surface illuminance (lux) and luminance meters to quantify the directional surface luminance (cd/ m2). The Daylight-Europe project (Fontoynont 1999) has developed simple procedures for the measurement of material optical properties such as the normal–normal transmittance of non-diffusing glazing under a point light source, the hemispherical–hemispherical transmittance of clear, tinted or diffusing glazing under a diffuse light source, and the reflectance of diffuse or specular surfaces.
20.4
Integrated performance rating
At the core of all simulation programs is a detailed mathematical representation of the heat transfer processes occurring within the building. At its most general, the approach taken is to transform the real system to a discretised equivalent and to represent each part by conservation equations relating to energy, mass and momentum exchanges. The problem then becomes one of estimating the temporal evolution of the parameters comprising the coefficients of these equations and arranging for a whole-system equation solution under the influence of time-varying boundary conditions. It is widely accepted that integrated modelling defines a new best practice approach to energy systems design because it allows designers to address important new challenges such as the linking of energy, the environment, comfort and health. In use, the approach requires the gradual evolution of a problem’s description, with performance outputs becoming available at discrete stages as the design detail improves. The design team is then free to terminate model building when the objectives have been achieved. Models such as those described in the preceding section, along with their related parameter values established by laboratory or in situ testing and as summarised in Table 20.1, have been encapsulated within building performance simulation programs so that advanced façade options may be readily appraised. The approach is accurate, in that the various energy transport mechanisms are explicitly represented, and rational in that performance is quantified in terms of a range of relevant criteria addressing technical, environmental and comfort issues. Figure 20.6, for example, shows an integrated performance view (IPV; Prazeres and Clarke 2005) as output by one contemporary building simulator, ESP-r (Clarke 2001). An IPV reports on issues such as seasonal energy demand, thermal/visual comfort, daylight
© Woodhead Publishing Limited, 2010
Assessing and benchmarking the performance
495
Table 20.1 Experimentally derived parameters as required by advanced façade modelling and simulation Component
Parameters
Material bulk properties
Conductivity, density, specific heat capacity
Surface finish
Emissivity, absorptivity, reflectivity
Glazing
Angular transmissivity, reflectivity and absorptivity
Transparent insulation
Maintenance impact on solar transmissivity
Photovoltaic cells
Open circuit voltage, short circuit current, maximum power point current
Ducted wind turbines
Power coefficient
utilisation, renewable energy contributions and environmental impact in relation to global warming, atmospheric acidification and ozone generation potentials. The following section demonstrates the application of the integrated modelling technique to the design of an advanced façade in a manner that gives rise to a self-referential benchmarking technique.
20.5
Application in practice
To illustrate the integrated modelling approach to advanced façade design, this section summarises two projects: the encapsulation of transparent insulation material and solar control devices within the façade of a new student residence located at the University of Strathclyde, and the encapsulation of all the above-mentioned technologies within a refurbished building in Glasgow.
20.5.1 Case study 1: student residences This project (Roddick et al. 1993) entailed the development of accommodation for 376 students and included pre-design modelling and post-occupancy monitoring. As depicted in Fig. 20.7, the development incorporated a 1040 m2 solar façade containing transparent insulation (polycarbonate honeycomb) and an automated solar shading mechanism. Figure 20.7 also shows the façade cross section and summarises the operational principle. Heat flux sensors embedded in the façade indicated a dark U-value of 0.6 W/m2K with the shading device open and 0.48 W/m2K with the device closed. Over the heating season, more energy enters than leaves the façade; hence an overall U-value of –0.08 W/m2K. The normalised performance indicator (NPI) value of 168 kWh/m2.yr represents a 40% improvement on the ‘good’ classification for a building of this type. Post occupancy monitoring quantified the contribution to the heating load
© Woodhead Publishing Limited, 2010
W/m2
W/m2
20 0
Heating
Guth Index, person seated with window on left.
© Woodhead Publishing Limited, 2010
7 9 11 13 15 17 Hour (during occupancy)
Non renewable Global warming potential Photo. ozone potential Acidification potential (kg CO2(eq)/m2·y) kg Ethytlene(eq)/m2·y) (kg SO2(eq)/m2·y) energy (MJ/m2·y)
800
50
0.08
40
600
0.06
30
400
0.04
20
0.25 0.20 0.15 0.10
Daylight 8 6 4 2 0.5 1.5 2.5 3.5 4.5 Distance to facade (m) Acoustic comfort
1.0 0.8 0.6
Meeting room Single office 0.4 0.00 0 100 250 400 1000 2500 0 0.00 ucpte ch ucpte ch ucpte ch ucpte ch Frequency (Hz) Construction Utilisation Deconstruction Heating Lighting Equipment Energy demand (w/m2) Typical spring day Typical summer day Annual Typical winter day 60 Heating 270.0 MJ/m2·y Heating lighting Equipment Heating lighting Equipment Lighting 9.7 MJ/m2·y 40 Equipment Lighting Equipment 30.1 MJ/m2·y Total 310.1 MJ/m2·y 20
200
0
1
0.02
10
5
9 13 17 21 Hour
1
5
9 13 17 21 Hour
20.6 An integrated view of building performance.
0.05
1
5
9 13 17 21 Hour
Materials for energy efficiency and thermal comfort in buildings
0 Lighting
Visual comfort
Summer Transitional Winter
40
10
Life cycle assessment
Thermal comfort
Daylight factor (%)
60
Reverberation time (s)
Capacities
496
Solar façade Transparent insulation façade with solar control and ventilation heat 30 recovery 20
Toughened glass Space for roller blind Transparent insulation
Solar radiation
Interior
2 mm 85 mm 100 mm 6 mm
20.7 Solar façade at the University of Strathclyde student residences.
10 mm
200 mm
Assessing and benchmarking the performance
© Woodhead Publishing Limited, 2010
Transparent sheet Air gap Heavyweight wall
497
498
Materials for energy efficiency and thermal comfort in buildings
from the façade as 293 MWh/year, while a survey showed that 91% of the occupants were ‘satisfied’ or ‘very satisfied’ with the internal environment – the average room temperature in winter was 20–24 ∞C.
20.5.2 Case study 2: commercial refurbishment This project (Clarke et al. 2000) was undertaken as part of the renovation of a former Glasgow Herald building – a notable Charles Rennie Mackintosh design – to create ‘The Lighthouse’, Scotland’s Centre for Architecture and Design as depicted in Figure 20.8. Modelling and simulation was used to search for façade-oriented technologies that effected a favourable match between the supply from façade-integrated renewable energy components and building electricity and thermal demands. The outcome from this search included: ∑
advanced glazings to minimise heat loss without significantly reducing daylight penetration; Portion of building with demand reduction measures and served by renewable components Hybrid PV façade
Ducted wind turbines (DWT)
Back of DWTs showing integral PV spoiler
20.8 The Lighthouse Building in Glasgow.
© Woodhead Publishing Limited, 2010
Assessing and benchmarking the performance
∑ ∑ ∑ ∑ ∑ ∑
499
a façade with transparent insulation and integral solar control blind to translate solar energy over time to offset heating requirements; dynamic indoor temperature and illuminance set-point adjustment; an array of ducted wind turbines (DWT) to meet a portion of the power demands during the winter and transitional seasons; a PV array to meet a portion of the power demand during the transitional and summer seasons (this array was subsequently incorporated within the spoiler of the DWT); a hybrid PV façade to meet a portion of the power and heat demands during the transitional and summer seasons; and a battery storage system to meet the temporal mismatch between the demand and supply.
Figure 20.9 shows the cumulative impacts of the demand reduction measures: a 68% reduction in annual energy demand (corresponding to a 58% reduction in heating and an 80% reduction in lighting). Significantly, the final demand profiles are better matched to the output from the locally deployed renewable energy (RE) systems. As shown in Fig. 20.10, the hybrid PV component was subsequently incorporated within the south-facing façade, while the DWTs were mounted at the top edges of the south- and west-facing façades. The predicted power outputs from the two RE technologies are also shown superimposed on the most favourable demand profile. Because of the residual temporal mismatch, the RE supply could be used to meet approximately 65% of the total demand. This figure would fall to approximately 20% for the case where the demand reshaping measures were not first applied.
20.6
Benchmarking façade performance
While there are many information sources on good and best practice building design, there is a paucity of data on the performance contribution of advanced façades that incorporate technologies as above. One way to assess the benefits that may be expected to accrue from the different possible façade technology deployments is to revisit other results obtained from the integrated simulations but not reported here. In the case of the Lighthouse building, the initial performance of 200 kWh/m2·yr for heating and lighting could be improved to around 150 kWh/m2·yr by the deployment of advanced glazing for heat loss reduction, and to around 65 kWh/m2·yr by the additional deployment of TIM and daylight capture/utilisation. The integration of PV and DWT technologies, which were made viable by the reshaped demand profiles, resulted in the production of around 100 kWh/m2·yr, although not all of this was utilisable because of the temporal mismatch. In the case of the student residences, the solar façade resulted in a 40% reduction in the NPI – from 280 kWh/m2·yr to 168 kWh/m2·yr. © Woodhead Publishing Limited, 2010
500 W/m2
Materials for energy efficiency and thermal comfort in buildings Design scenario Energy demand per unit time
200 Heating 160 Lighting 120 Summer Transition Winter 80 40 0 1 5 9 13 17 21 24 1 5 9 13 17 21 24 1 5 9 13 17 21 24 Time (hours)
200 160
Annual energy demand (kWh/m2·y) Base Case: Heating 118.3 Lighting 100.1 Total 218.4
As above + advanced glazing:
Heating Lighting
Transition Winter 120 Summer Heating 80 Lighting 40 Total 0 1 5 9 13 17 21 24 1 5 9 13 17 21 24 1 5 9 13 17 21 24 Time (hours) Heating Lighting
200 160
Transition Winter 120 Summer 80 40 0 1 5 9 13 17 21 24 1 5 9 13 17 21 24 1 5 9 13 17 21 24 Time (hours)
As above + transparent insulation + daylight utilisation: Heating 38.2 Lighting 41.6 Total 79.8
As above + efficient lighting + responsive heating:
Heating Lighting
200 160
Transition Winter 120 Summer Heating 80 Lighting 40 Total 0 1 5 9 13 17 21 24 1 5 9 13 17 21 24 1 5 9 13 17 21 24 Time (hourz) 200 160
Heating Lighting
PVh PVe
64.5 41.6 106.1
DWT
Transition Winter Summer 120 Heating DWT PVe 80 PVh Lighting 40 0 1 5 9 13 17 21 24 1 5 9 13 17 21 24 1 5 9 13 17 21 24 Time (hourz)
As above + active renewables: Heating Lighting Total DWT PVe PVh
20.9 Impact of progressive deployment of demand reshaping measures.
© Woodhead Publishing Limited, 2010
49.0 20.0 69.0
49.0 20.0 69.8 25.0 33.8 41.0
Assessing and benchmarking the performance
Energy per unit time
Heating PVh
Winter day
Spring day
Lighting PVe
DWT
501
Total demand: 68 kWh/m2·yr Total RE supply: 98 kWh/m2·yr
Summer day
20.10 Embedded RE systems in The Lighthouse Building, Glasgow.
Arriving at such low energy façade solutions requires a procedure for systematically analysing the different demand/supply options. This is made possible within the modelling and simulation approach by adherence to a performance assessment method that explores the impact of the different possible technologies when deployed separately and jointly. In the case of the Lighthouse building, for example, the cumulative impacts shown in Fig. 20.9 comprise only a sub-set of those actually considered but discarded for a variety of project-specific reasons. The important point is that the initial design must not be constrained by the incorporation of particular low energy features. Rather, these features should be systematically added to the initial design so that the impact of each feature may be judged in a relative manner and suitable outcomes retained. Clearly, the actual features considered will change with time as existing technologies become cost-effective and new technologies emerge.
20.7
Sources of further information and advice
Perhaps the most definitive source of information on the concepts, technologies and tools for high performance building façade solutions is the resource base maintained by the Environmental Energy Technologies Division at the Lawrence Berkeley National Laboratory (see http://lowenergyfacades. lbl.gov/resources.html). Another useful website on the topic is maintained at http://www.energy.soton.ac.uk/buildings/facades.html, while Selkowitz (2001) has given a useful overview of the issues underpinning advanced façade design. © Woodhead Publishing Limited, 2010
502
20.8
Materials for energy efficiency and thermal comfort in buildings
References
Buresch M (1983) Photovoltaic Energy Systems – Design and Installation, McGrawHill, New York. Clarke J A (2001) Energy Simulation in Building Design, 2nd edn, Butterworth-Heinemann, London. Clarke J A, Johnstone C M, Macdonald I A, French P, Gillan S, Glover C, Tatton D, Devlin J and Mann R (2000) ‘The deployment of photovoltaic components within the lighthouse building in glasgow’, Proc. 16th European Photovoltaic Solar Energy Conf., Glasgow. Fontoynont M (ed.) (1999) Daylight Performance of Buildings, James & James, London. Grant A D, Johnstone C M and Kelly N (2008) ‘Urban wind energy conversion: The potential of ducted wind turbines’, Renewable Energy, 33(6), 1157–1163. Hutchins M (1998) ‘Advanced glazings: a status report’, Sunworld, 22(1), 5–11. IEA (2002) ‘Photovoltaics/thermal solar energy systems: Status of the technology and roadmap for future development’, Task 7 Report, International Energy Agency PVPS T7-10. Imbabi M S and Peacock A (2004) ‘Allowing Buildings to Breathe’, Renewable Energy, 29, 85–95. Loncour X, Deneyer A, Blasco M, Flamant G, and Wouters P (2004) Ventilated Double Façades – Classification and illustration of façade concepts, Belgian Building Research Institute. Prazeres L and Clarke J A (2005) ‘Qualitative analysis of the usefulness of perceptualisation techniques in communicating building simulation outputs’, Proc. Building Simulation ‘05, Montreal, International Building Performance Simulation Association. Roddick G, Twidell J W and Johnstone C M (1993) Final Report for Contract SE/324/87, European Commission. Selkowitz S E (2001) ‘Integrating advanced facades into high performance buildings’, Paper LBNL-47948, Lawrence Berkeley National Laboratory. Selkowitz S, Aschehoug O and Lee E S (2003) ‘Advanced interactive facades – critical elements for future green buildings?’, Proc. GreenBuild, Lawrence Berkeley National Laboratory. Wittwer V and Platzer W (2000) ‘Transparent thermal insulation materials and systems: state of the art and potential for the future’, J. High temperatures, high pressures, 32(2), 143–158.
© Woodhead Publishing Limited, 2010
21
Advanced building materials and eco-building design
B. W a t t s, Max Fordham LLP, UK
Abstract: This chapter is a review of the issues surrounding the design of environmentally responsible buildings. The brief for the environmental conditions (temperature and humidity, light, sound, air quality and their effect on health) inside a building will affect how much energy is required to achieve the conditions and the ease that low energy and passive solutions can work. A building is not isolated and needs to consider the energy, water, food and material sources needed for its construction and operation, and how they sit in wider local, regional and global context. The design of the building envelope and the building fabric will affect the comfort conditions in the building and the ability to achieve these passively. The design of the façade will affect the day-lighting and the potential for natural ventilation. The choice of materials will also affect the management of the internal environment such as the buffering of the temperature and humidity. A successful building project is as much about the successful procurement, construction and operation as it is about design. These matters need to be dealt with carefully. A brief for materials of the future is one of greater extremes in some instances; higher insulation values, better moisture absorption, higher thermal capacity. Another aspect is to make the materials dynamic in their performance such that they can vary their parameters such as insulation, light transmission and permeability according to need. These materials could come from the living world as much as the inorganic, man-made one. Key words: environmental brief, comfort, insulation, acoustic materials, water, heating, cooling, thermal buffering, moisture buffering, daylight, internal pollution, biological building, passive design, energy use, energy storage, dynamic materials, building health.
21.1
Introduction
There are many aspects that go under the heading of ‘eco’, many of which are highly subjective according to one’s own perspective and can sometimes be largely unquantified. The general thrust of the term is that one carries out human activities on the earth without harming the environment too much. This book is a scientific publication that tries to quantify these issues where it can, but in some cases the networks are so complex and in themselves unquantified making it difficult. The value judgment about the amount of harm 505 © Woodhead Publishing Limited, 2010
506
Materials for energy efficiency and thermal comfort in buildings
one does to the environment that is acceptable is in itself a very hot topic. Lifting the sprits of those using the building is one of these aspects that is fundamental to creating a space that will be well loved, used, retained and is sustainable compared to one that is demolished because no one wants it.
21.2
Issues in eco-building design
21.2.1 Comfort and health in buildings The primary function of buildings is to provide comfortable and healthy environments for its occupants. This is especially important as people spend most of their time either in buildings or inside a vehicle of some sort to get between them. The brief Comfort involves not being too hot or cold, having enough light to see, having a reasonable air quality, and not too much noise. One’s perception of comfort links to other psychological factors such that the more in control one is of one’s environment and the happier one is at work, the more forgiving one is of the comfort standard one is in. The reverse is true of being less tolerant when one is not happy or in control of one’s environment. There is a trend for standards to go up as we get more affluent. While this is not necessarily a bad thing, it can come at a cost in terms of energy use. One needs to be careful of standards that are written from a single issue point of view, that may not take into account wider issues. As an example, building guidance documents have been produced by the education authorities in the UK concerning the acoustics of a school (Building Bulletin 93, 2003). When combined with the requirements for ventilation standards set out in Building Bulletin 101 (2006), a designer was cornered into mechanically ventilating the classroom as an opening window would not provide adequate sound separation. As this was not the intention of the authorities the guidance was amended with subsequent guidance for naturally ventilated designs. Generally the looser the environmental control required, the easier it is to meet with a low energy strategy. It is essential that the environmental range of the comfort variables are agreed with the client or occupants of the building before setting about the design. Thermal comfort Thermal comfort is a mixture of dry-bulb temperature, humidity, radiant temperature and air movement, set against how active one is and the amount of clothing. By altering the level of clothing one can remain comfortable in
© Woodhead Publishing Limited, 2010
Advanced building materials and eco-building design
507
a range of temperatures. As such it is possible to save the energy required to give close temperature control by asking people to adjust their clothing. Light Light is required for most tasks in a building. The eye can accommodate a wide range of light levels from moonlight at 0.1 lux to bright sun at 100 000 lux. The requirement for light varies according to the task and the visual acuity and age of the person. For reading, levels of 300 to 500 lux are considered acceptable. Higher light levels are beneficial for those with greater visual impairment. While the eye can accommodate big ranges of light levels, it takes time to do so. It cannot cope with big variations in the same field of view. As such having a reasonably even level of illumination is as important as the absolute level. One can only see the silhouette of a person against a bright window. Also, an adequately lit room that has high light levels on one side by the window will look gloomy due to the contrast. Sound Acoustics and noise is another environmental factor that affects comfort. High noise levels can be stressful, affect sleep and the quality of acoustic communication, be that talking, teaching or listening to music. Exposure to high noise levels over long periods of time will impair hearing and is limited by health and safety legislation (The Noise at Work Regulations, 1989). The ambient noise levels are affected by noise from an external source like a road, and the management of the sound generated in the space itself. Getting sound separation between spaces requires solid and heavy materials as the partition. Reducing the noise level in a space from the noise generated in the space (like a swimming pool or restaurant) requires absorbent materials to line the surfaces of the space. These tend to be soft or porous. Getting air through a sound separation partition is possible if the air path is elongated and lined with absorbent material. Health While any of the issues to do with comfort can affect one’s health, there are other less immediate effects that are not picked up by the senses. High humidity can allow biological activities such as dust mites and mould growth that give rise to respiratory diseases. Controlling the humidity and the absolute moisture levels in spaces is one of the fundamentals of a healthy building. Some building products give off potentially irritating gasses (offgassing) either at the beginning or throughout the whole of their lives. There are also external sources of pollutants such as oxides of sulphur (SOx), and
© Woodhead Publishing Limited, 2010
508
Materials for energy efficiency and thermal comfort in buildings
of nitrogen (NOx) from combustion processes such as vehicle engines, power stations or incinerators that can affect health. Whilst buildings do not contribute to these pollution sources (apart from housing the people who are using the vehicles, power and producing waste), they can help reduce the level of pollutants inside. Particulates in the air are another irritant and hazardous pollutant. Pollen is well known to cause an allergic reaction in some individuals (hay fever). However, small dust particles of less than 10 mm in diameter (PM10 and PM2.5, etc.), not immediately perceived by humans but get drawn deep into the lungs, are linked to cardiorespiratory disease. The source of these is again linked to combustion and industrial processes that involve the movement and pulverising of solids. In the developed economies, such as the UK and US, the levels of pollution in general have been dropping due to better environmental controls and de-industrialisation (National Atmospheric Emissions Inventory, UK; US EPA). However rapidly developing countries such as India and China have seen their pollution levels increasing in line with their industrialisation. This is being monitored by organisations such as Regional Air Pollution in Developing Countries, a Swedish based organisation. There are also high natural sources of PM10s in dusty desert environments (Bouchlaghem et al., 2009)
21.2.2 Materials and waste in eco-design Generally an ‘eco’ design will use less material or resources which can be measured. The waste that is produced in the production of building material and the eventual disposal of the building is important. The cycle of taking minerals out of the ground to create products, producing pollution in the process and putting them back into the ground when we have finished with them is being challenged. This linear way of doing things is very cheap provided the economic externalities due to the pollution, loss of amenities, or the replacement costs of the resource are not taken into account. However, these other costs and consequences are now being brought to bear in legislation that taxes, limits or bans activities that harm the environment, forcing more benign solutions to be sought. One way of limiting the use of fresh resources is to create cycles of materials whereby the output and waste of one cycle feeds another, and eventually the loop is closed. This benign view of materials favours products that can be reused as complete elements and then broken down into their component parts and possibly reformed into other complex systems. Glass is a good example of this process, and some cars are now being designed with this in mind. Building elements, however, have not in the past been easy to recycle without considerable labour and energy. It may be that the energy involved in returning a commonly available element into the supply
© Woodhead Publishing Limited, 2010
Advanced building materials and eco-building design
509
chain is not worth the energy needed to reprocess it. Burning combustible materials to reclaim the energy is one way of dealing with the issue that ignores any of the embedded energy in the manufacture of the material. Products from the living world do have a ready-made recycling system. Complex structures and processes are generated ultimately from plant life using solar energy, and can be recycled back into the component parts used to build them, namely nutrients, CO2 and water and can potentially release the energy gathered to make them.
21.2.3 Energy efficiency in buildings One of the main resources that we are looking to conserve is fossil fuel energy. Putting the carbon that was in the form of gas, oil, and coal from the ground into the air (e.g. as CO2, CH4, etc.) is generally acknowledged to be affecting our climate. The fossil fuel resource is finite and as they get more scarce, problems of conflict arise to secure a nation’s supply. Renewable energy sources such as wind, solar, tidal or biomass, etc., will not increase the CO2 level in the atmosphere. However, compared to fossil fuel it is very capital and labour intensive, which is the reason we made such use of fossil fuels to drive the industrialisation of the last two centuries. Ideally we should be using the cheap fossil fuel as a scaffolding to build the technology to provide the energy we need from renewable energy sources. This is as much driven by a national energy security agenda as a sustainability one. Energy sourced locally from renewable sources reduces one’s reliance on imported energy that could be shut off or exposed to big cost fluctuations driven by world events. Getting agreement on the technical solutions to do this is difficult given the wide range of expertise required, but it is susceptible to analysis by numbers. The heating, lighting, cooling, ventilating and general powering of buildings are responsible for a substantial proportion of the energy used in the world. In the US it is estimated at 40% (US DOE). This ratio is similar around the world. As such, materials that can reduce the need for energy in a building are a benefit, and would earn the term ‘eco’. McKinsey & Company have done an assessment of the costs of the various ways of reducing CO2 production (McKinsey, 2008). On this analysis energy efficiency measures to reduce energy consumption are far more cost effective than generating the power from renewable sources. David MacKay (2008) has done an excellent job of looking at the whole issue of energy usage and production in the UK, and putting forward a number of models that make the supply and demand add up in a zero fossil fuel economy. MacKay is a physicist and not an expert in any one of these technologies. That is of less importance than the framework he has produced to get the various methods of supply and demand on the same piece of paper using the same units such that they add up. The technologists can
© Woodhead Publishing Limited, 2010
510
Materials for energy efficiency and thermal comfort in buildings
then challenge his figures and argue the case on a like-for-like basis. That, however, is simple compared to dealing with the various powerful interest groups, the owners of the existing assets – often the pension funds, subsidy and taxation regimes, planning and regulatory issues. Variability of renewable energy The energy collected from wind, waves, solar and tidal, etc., varies according to the weather, season and time of day. While we can predict these natural forces we cannot control them so the energy produced will vary according to the supply rather than our demand for it. This is very different from fossil fuels where the energy is stored in a chemical form that can be turned into other forms of energy any time one wanted. It is true that biomass from plants is a renewable source of stored chemical energy, but production is limited by the land available, land that is competing for use for food production and indeed nature. While conserving energy usage is an immediate priority in order to reduce demand, in the future it may be more to do with matching the output of the energy producing assets with the demand. As such the storing of energy will be as important as the source. It can be compared to the collection and distribution of water, a renewable resource we currently rely upon. The rain is intermittent but by and large seasonally predictable. It is collected and stored in centralised reservoirs. However, there has been a requirement for local storage of water by the consumer. In the UK the size of storage for a dwelling was historically set to 50 gallons or 225 litres which was considered daily usage at the time the regulation was conceived early in the 20th century. The average use per person in the UK is now 150 litres per day per person, i.e. 600 litres for a family of 4 (DEFRA, 2009a). In Western Australia, the daily water consumption inside the household is similar at 500 to 600 litres per day but an additional 1000 to 2000 litres per day can be used in the summer months for watering gardens (Loh and Coghlan, 2003). There are two benefits of local storage. Firstly, the distribution network does not have to deal with the peaks in demand and so can be smaller. Secondly, it will provide a continuous supply of water during a short-term interruption of supply. This makes it a more robust system as a whole. By comparison renewable energy production is more continuous than rainfall so storage is required more over a cycle of hours rather than weeks or months. Electrical energy is much more problematic to store in large amounts. While there are large central systems like pumped hydro-electricity storage, they are expensive. If it is possible to provide the energy storage at the point of use, it will create a greater resilience to intermittency in the supply system. Buildings are the largest users of energy and incorporating storage into them will increase the resilience of the network and enable the more widespread use
© Woodhead Publishing Limited, 2010
Advanced building materials and eco-building design
511
of renewable energy. While electricity is the most versatile source of energy, we do not use it directly. It is the heat, light, computing power and motive force we use. While heat (or cool) is relatively easy to store, especially in a building, the light, computing power, and motive force is harder. For these one needs to either differ their usage or store the electrical potential energy. With the advent of portable electrical equipment this storage in batteries is becoming more widespread, and could be mobilised to manage the demand as well as providing the convenience of portability. Cars are an excellent example of this. They are a portable appliance with a comparatively large energy generator and store that are parked next to buildings when not in use. Electric vehicles allow one to use the battery as a local store. Hybrid vehicles are comparatively large generators that could provide more than sufficient power and heat for a typical dwelling. The Toyota Prius has a 50 kW peak capacity electrical generator (Wikipedia a). This is more than three times the size of the standard 60 amp, 14.4 kW domestic electrical mains connection. While that will cover the absolute peak consumption, the average electrical consumption is much lower. Work at Strathclyde University suggests that a family with parents working and two children at school uses 5480 kWh per year which averages out at 0.63 kW continuously. (Anon (a)). Designing systems that link transport vehicles to buildings is a part of future thinking of energy usage. Finally, if one is storing electrical energy in some system, be that a battery or a hydrogen hydrolysis/fuel cell cycle, there will inevitably be inefficiencies in the system that will manifest themselves as heat. It is more likely that the building will be able to make use of some of that heat to make hot water or space heating that would otherwise be lost in a central electrical storage system.
21.2.4 Food and water Water and food are linked renewable resources that we rely on that are not infinite. Food requires water to grow and in many areas is the limiting factor in agricultural productivity. As world population grows, strains are put on water supplies which tend to be more local to the user, but food which can travel longer distances can also be a limiting resource. The benefits of using less and gathering the resource locally applies to food and water as it does energy. If a building can use less water and can collect water and grow its own food, it will alleviate the central supply issues in a similar manner to that which a local solar panel does with energy.
21.2.5 Buildings and the external environment The urban form has historically been hard edged and impermeable using materials such as brick, glass, concrete and asphalt. As such, rainwater is
© Woodhead Publishing Limited, 2010
512
Materials for energy efficiency and thermal comfort in buildings
shed very quickly from the surface and into the drains. This has created a problem of overloading the drainage systems, be they man-made pipes and culverts or the natural river systems. This in turn causes flooding, perhaps not at the point of rainfall but some way downstream. The other big loser is the biodiversity and vegetation that cannot live on hard surfaces. Having softer planted areas and retaining the rainwater that falls and allowing it to percolate more slowly into the ground will create more natural habitats for nature and help alleviate the problem of flooding (Anon (b)). Hard surfaces and the heat from human activity has historically raised the temperature of urban areas above the surrounding planted areas. The ‘urban heat island’ could be considered a bonus when it is cold but not when it is hot. Again, planting on buildings will reduce the temperature of the building surfaces and the cities in general (Alexandri and Jones, 2008), The countryside is increasingly used for intensive food production using monoculture crops with herbicides and pesticides, which will tend to force out wildlife that does not fit with this land use. As such, urban areas and gardens can provide refuges for wildlife that may have been forced out of the countryside. Buildings that create habitats for biodiversity and retain water are also considered ‘eco’.
21.2.6 Use of space Humans are also social animals. We have lived in communities that became towns and cities to meet, talk, trade and generally network. Petroleum and cars have allowed us to travel greater distances and live spread apart in low density suburbs. While this provides a sense of space and personal freedom, it uses up a lot of space and fuel, and can lose the social cohesion of the community. Development also tends to reduce the land available for agriculture and nature. Again, while not part of this book, the planning of larger urban areas will have an effect on how sustainable the development is. Climate change It is widely believed that the climate is going to change in the coming decades and that buildings will need to be able to cope with these changing conditions. In general, the effect is said to be that the weather will be hotter which will reduce heating loads in the winter but increase overheating in the summer. The rainfall is thought to come in storms in shorter bursts. Storm events in general are predicted to increase with the problems of wind damage and flooding. These issues are current in the advice given to designers by planning authorities. The UK government has produced a review of the expected implications in the UK and tools to help mitigate the effects (DEFRA, 2009b).
© Woodhead Publishing Limited, 2010
Advanced building materials and eco-building design
513
Social equity Coming back to the social side of sustainability or sustainable development, one does need to take into account the well-being of people. This is another big topic in itself, but ‘eco’ design should be promoting economic and healthy well-being for all the people involved. This includes the supply chain of those involved in the supply and manufacture of the products we are developing. The UK has been successful in reducing the CO2 emissions and ‘decarbonising’ the economy. In reality, much of this has been achieved by moving the manufacturing sector that used the energy to lower cost base economies such as China. As such the carbon emissions from western manufacturing have not disappeared but merely moved out of the country. As there is a greater use of coal as an energy source in China with a higher carbon content than the UK mix of energy supplies, one could argue that the net effect is to raise the carbon content of manufactured goods. Investment in new versus existing buildings In the older developed economies the existing building stock and infrastructure is the major issue to address. Raising the standards of this stock by retrofitting is a key problematic task. However, how the next generation of new buildings and cities get put together in the rapidly developing economies will determine how much of a resource and energy problem we have in 2050.
21.3
Challenges of sustainable development for a designer
These elements of sustainable development are not all compatible with each other and indeed can be contradictory. It is very hard to be completely objective about these issues as one tends to find that one has a definition that favours one issue over another. Biodiversity, social equity, waste minimisation, embodied energy, or energy in use. All these things compete such that the eventual design is a compromise of some sort or another. As a rule the designer is being asked to get more for less. That is more comfort, usable space, biodiversity, social inclusion, for less resource, land, space, energy and above all money. Better pallets of materials will help that task.
21.3.1 Environmental control in a building The idea of a building is to modify the external climate such that it is more comfortable inside than out. The external conditions like temperature, wind and sunlight vary and by altering the permeability of the building fabric one can moderate the internal environment. However, with the advent of
© Woodhead Publishing Limited, 2010
514
Materials for energy efficiency and thermal comfort in buildings
technology and use of energy we can create more or less any internal climate and comfort conditions without reference to the external environment. As we are looking to save energy we are looking to get back to using the passive mechanisms for this environmental control.
21.3.2 Light and daylight Daylight can be used to displace the need for electric light. The sky is the source of daylight and the greater the view of it the better. Per unit area of glass, a roof light provides more light than a window as it is facing the brightest part of the sky compared to the window that has a more restricted view. Light travels in straight lines and the overall light level in a space is determined by light directly from the source and the diffuse light that has reflected from the surfaces in the room. Daylight does need managing and doesn’t travel very far into a room. The general rule of thumb is that the light will travel 1.5 to 2 times the storey height from the façade into the room. There is a problem with the variation in lighting levels across the room. This is normally dealt with by having most of the windows at the ceiling level and limiting the fenestration below or shading it with a ‘light shelf’. Reflecting the light into the back of the room has been tried on occasion with mixed results. The same issues of variation of light levels applies to artificial light and one tends to mount ceiling mounted light fittings one to two ceiling height apart to give a reasonably even light distribution. The closer the finishes are to white the further the light will penetrate the room. The sun rises in the east and sets in the west. One needs to be aware of the low direct sun in the morning and afternoon on the east and west façades. However, the further one moves away from the equator, the more the path of the sun varies between summer and winter. In the Arctic Circle, the sun never comes up in mid winter and never goes down in mid summer. This has to be taken into account in designing shading systems. South facing glazing in a northern temperate latitude will benefit from low winter sun to help warm the space. A slight overhang will shade the façade in the summer from the higher summer sun. Any façade that has sun on it will generally need some control over the size or transparency of the opening to prevent glare or overheating. Climates with consistently high daylight levels need smaller areas of fenestration for daylight than duller climates. From a utilitarian pragmatic point of view, the extent of glazing should be limited to provide enough daylight and no more, to limit the extent of overheating and heat loss. Light is a subset of electromagnetic radiation which in itself is a subset of the different forms of energy. Not all the energy from an electric light is radiation; some is heat lost through convection from the heat generated from the gear and warm lamps. However, all energy be it from electricity or radiation will eventually get degraded into heat. The
© Woodhead Publishing Limited, 2010
Advanced building materials and eco-building design
515
energy becomes less useful but does not get lost. From a cooling perspective the light directly from the sun has less heat in it than a fluorescent light. The brightest light levels from the sun are about 100 000 lumen/m2 with a heat flux of 1000 w/m2 giving a rating of 100 lumen per watt. Selective coatings on glass can take out the invisible infrared and UV and increase the relative light to heat ratio. Pilkington Suncool 6 mm 70/35 will let through 69% of the daylight and 37% of the radiant heat. The light to heat ratio will go up to 100 ¥ 69/37 = 186 lumen per thermal watt. By contrast a reasonable fluorescent lamp will provide 68 lumen per circuit watt, going up to 90 for a high frequency ballast T5 lamp running at 35 °C (Osram lighting data). However, while the sunlight may be more efficient than a fluorescent light, it is much more difficult to control. The fenestration also provides a view especially in tall buildings, with the drama of looking down. This leads to highly glazed façades that are difficult to justify environmentally, from a solar heat gain and a heat loss point of view, but delightful to look through.
21.3.3 Heating One of the basic attributes of a comfortable building in a cold climate is that it is warm in the winter. Heat energy is put into the building to maintain a thermal gradient between inside and out. The rate of heat loss is a function of the level of insulation in the external envelops and the volume of external air coming in that needs to be heated up. Increasing insulation standards will reduce the fabric heat loss, and making the building well sealed will reduce the amount of air that needs to be treated. Increasing the insulation levels of the external elements will also raise their internal surface temperature, and reduce the discomfort of a cold radiant surface and cold down drafts in the room. The heat loss from the ventilation air can be further reduced by using the outgoing air to pre-heat the incoming fresh air. This is normally done in conjunction with a fan powered ventilation system to overcome the resistance of the heat exchanger, although wind powered versions are said to function. As the lighting (both electrical and daylight), computers, IT equipment and the people themselves all give off heat, it is possible to see how the building could be warmed with little or no additional energy, particularly if it is recovering the heat from the outgoing air. If the internal heat gains are sufficient to warm it in the coldest periods, it must be overheating at all other times. If the heat gains exceed the losses for most of the time that the building is occupied, then the case for the added complexity and electrical fan power for heat recovery is difficult to justify.
© Woodhead Publishing Limited, 2010
516
Materials for energy efficiency and thermal comfort in buildings
21.3.4 Thermal storage Ideally the excess heat should be stored for times when the heat loss exceeds the gains. This can be done in the surfaces (walls, floors, ceilings), furniture and loose fittings in the room. Driving heat into and out of the building fabric requires a swing in the room temperature. This is particularly true of phase change materials that have a few degrees of hysteresis. A tight environmental control brief will therefore make it very difficult to make use of the thermal mass as the room temperature may not be allowed to deviate sufficiently to drive the heat into the fabric. Ideally the thermal mass needs to be in the space, connected by radiation and convective heat transfer. Covering it with an insulation material will increase the thermal gradient required and consequently the swing required to make use of the thermal storage. The thermal mass of a material is governed by its thermal conductivity, mass and specific heat capacity. The nature of storage is that it is cyclical. The longer the period of the cycle the further the heat can travel into a material and the greater the amount of heat can be stored. Analysis has shown that for dense material such as concrete, the amplitude of variation in temperature over a 24-hour cycle becomes small about 70 mm from the surface. The depth will increase over longer time scales. It is possible to use a remote heat store such as the ground, but some active mechanism is required to connect the mass with the space by moving air or water. Blowing air down the holes in pre-cast concrete panels that form the building slabs is a way of doing this. Thermodec sell this as a product.
21.3.5 Cooling In hot climates the situation is reversed from heating in that one needs to limit the heat coming in and employ means of getting rid of the internal heat gains. Insulation helps in a similar manner in reducing the heat flux, as does minimising the external air infiltration when it is hotter outside. The colour of the external surfaces (albedo) will affect the amount of solar radiation absorbed and hence the temperature (white is cooler), which will in turn affect the heat transmitted into the space. Thermal mass can help by absorbing heat when it is hot and getting rid of it when it is cooler, and the hot surfaces can radiate heat to the sky at night. Evaporation is one of the main forms of heat rejection in a cooling tower. Plants also keep cool by transpiration of water. Having a wet external surface in the form of a green planted roof or wall will keep the temperature of the surface down and reduce the heat gain if not do some active cooling. The other aspect of hot climates is that the external air has a higher humidity than the desired internal level, and it cannot be used for dehumidification.
© Woodhead Publishing Limited, 2010
Advanced building materials and eco-building design
517
The refrigeration load to dehumidify the air is often greater than the cooling load. One has to be careful of moisture coming in rather than going out. It is better for any transpiring planting to be on the outside rather than inside the occupied space where they would raise the humidity.
21.3.6 Ventilation The ability of the fresh air to help condition a space depends on the climate. In most temperate climates it can be used for cooling and controlling humidity. As mentioned above, it is a manner of controlling the temperature in a well-insulated building that is heated with its internal gains. When it is hot or very humid there are other mechanisms for cooling deployed and the fresh air needs to be treated using energy, and the amount limited to the minimum. The ventillation is often linked to the CO2 level in the building as there is a direct correlation between that and the occupancy. 8 litres of fresh air per second per person (l/s/p) will equate to a CO2 level of 1000 ppm and 3 l/s/p would be 1800 ppm. The correct amount of CO2 in a room is the subject of some debate especially in schools. The UK schools guidance document Building Bulletin 101 sets out a regime that allows one to have a natural ventilation system that has a minimal ventilation rate for most of the time which can be increased to provide rapid purge ventilation. Except in the case where the outside air is always the right temperature, the ventilation rate will need to be controlled. In a similar manner to daylight, the perimeter of the building can be opened to let in fresh air using wind pressure and the differences in buoyancy of the air. However, the wind and buoyancy forces to drive the process are highly variable. In the winter of a temperate climate, the buoyancy and wind forces are very high and the fresh air required is at its minimum. In the summer, very high volumes of air are required when the forces are very much lower. As such the openings need to be variable and controllable. This becomes more important as buildings are sealed up to reduce heat loss and one cannot rely on the background air permeability and infiltration rate. This is not a trivial design issue. The design needs to address: ∑ Stopping things going in or out, be they building occupants, burglars, dust, insects, birds or raindrops (Fig. 21.1). ∑ Opening and closing them: manual or automatic; links to the building controls system, accessing the opener. ∑ Dealing with the noise coming in or breaking out. By contrast, a mechanical fan assisted ventilation system will provide a controlled ventilation rate at a cost of the power needed to run the fan. The choice between natural ventilation and mechanical ventilation in many
© Woodhead Publishing Limited, 2010
518
Materials for energy efficiency and thermal comfort in buildings
21.1 Stopping things coming in or going out of a window is a design consideration (Author’s photo).
situations is a subtle one that depends on the ease of control and maintenance of the relative systems. As a rule of thumb, a room with openings on one side can be ventilated about three storey heights deep. Single-sided ventilation is largely driven by buoyancy. Having openings on both sides of a building or connected to a shaft to the roof will increase the natural ventilation by making use of wind pressure variations around the building. A taller volume of air will create a greater buoyancy driven stack pressure as well.
21.3.7 Internal moisture and pollutant control As well as regulating the heat loss and CO2, ventilation controls the removal of internally generated water vapour and other pollutants. It is important to control the level of these to maintain a healthy environment in a building. This is on the basis that the external concentration of the moisture and other pollutants are lower than internally, so external air will dilute the internal concentration. This is not always the case when the outside is more humid or polluted and has to be treated to bring it to the comfort standards required internally.
© Woodhead Publishing Limited, 2010
Advanced building materials and eco-building design
519
It is possible for the gases to diffuse to outside though the fabric down a concentration gradient. However, permeability and the differences in concentrations are generally too small to make this the only form of pollutant control. Indeed, the offgassing of materials and the naturally occurring radon coming from the rocks in certain areas of the UK such as Cornwall and the Midlands, mean there is more diffusing in than out. Having said that, moisture can diffuse through fabric and cause problems by condensing on cold elements in the construction if it is not controlled or allowed to escape. Generally speaking, the humidity levels in a building should be kept well below 70% to prevent mould growth. Surface areas of high heat loss without a compensating heat source are areas where the room air can cool down, increasing the relative humidity and risking condensation. Well-sealed buildings with carefully controlled ventilation rates will have higher internal humidities. This is not such a risk if there is a commensurate increase in the levels of insulation such that the internal surfaces are warmer. However, this situation will be less forgiving of any ‘cold bridging’ areas of poor insulation that will result in pockets of high heat loss and high surface humidity (Fig. 21.2).
21.2 The combination of cold bridging on the aluminium frame and poor air circulation in a well sealed building will lead to condensation and mould growth (Author’s photo).
© Woodhead Publishing Limited, 2010
520
Materials for energy efficiency and thermal comfort in buildings
Like heat, the moisture production in a building is not continuous and depends on the number of occupants, cooking and bathing activities. Absorbent materials will act like sponges to take up the moisture from the air when the concentration is high and release it over time when the moisture producing activity has ceased. This buffering is useful in preventing peaks of high humidity in the space, providing there is a time of low humidity when the material can dry out. Desiccants are very good at absorbing moisture from the air at low temperatures and releasing it at high temperatures. This is useful in active systems to remove humidity from the air and using heat to dry and regenerate the material.
21.3.8 Energy usage in buildings Energy is used in a building to provide heating, cooling, light, hot water, to pump air and water, and to drive appliances. The amounts vary according to the usage, climate and overall efficiency of the building. Traditionally the greatest energy usage in temperate climates has been the space heating. In hot climates this is replaced with the cooling. The amount of fan and pump power depends on the types of heating, cooling and ventilation systems used. The lighting load will depend on the building usage. However, it is the electrical demand of gadgets and IT that is increasing at a fast pace which generally the designer has no control over (Figs 21.3 and 21.4).
21.4
The eco-building design process
21.4.1 Client brief: environmental control standards and maintenance As discussed above, tight environmental control standards are possible but generally require energy to achieve. Wider limits on temperature, light levels, noise, air flow, etc., allow greater possibilities for the use of passive control. The extent to which the occupants are prepared to adjust their environment by operating blinds, opening windows, and the maintenance that arises from the materials and equipment used needs to be agreed. This will ensure that the conditions and the maintenance of the building, when delivered 2 to 4 years later, is not a surprise. Avoiding an unhappy client or user should be one of the main aims of the design process, and early dialogue on these issues is essential.
21.4.2 Fitting into the existing urban fabric The building should be fitting into the surrounding fabric in terms of the height and massing generally. In areas of historic interest there may well be © Woodhead Publishing Limited, 2010
Advanced building materials and eco-building design
521
kgCO2/m2/yr
50 45
2.5 2
40
2
35
6
Pumps/ Fans/ Controls Small power Lighting
6.5
15
30
4.5
Hot water
25 7.5
Heating
15
20 2.6 15
32
4 1
10
16
5 0
10 Historic secondary school benchmark (measured)
Typical recent city academy secondary school (measured)
New proposed Further Education college (estimated)
21.3 Newer buildings have lower heating energy consumptions but higher power usages. The increase in IT has a lot to do with this.
21.4 Example of growth area in energy use. Image from internet.
restrictions on the changes one can make to the external appearance of the building and to the historic building fabric itself. This can put considerable limitations on energy saving techniques to do with insulation. It is a challenge for new materials to make historic buildings more energy efficient and maintain their character.
© Woodhead Publishing Limited, 2010
522
Materials for energy efficiency and thermal comfort in buildings
Planning issues must be taken into account when considering large developments. Fundamentally the density of development will determine how far apart destinations such as schools, parks, shops, places of work, etc., are from each other, and how viable sustainable transport systems will be. Low density suburban developments have built up with a reliance on the car to provide convenient transport. The distances are too big to walk or cycle, and public transport will not have the custom to make it profitable. At higher densities, walking and cycling becomes possible and public transport becomes viable to provide frequent and convenient services. The density does not have to be like the towers of Hong Kong for this to work. London has terraces of buildings that are two to six storeys high that supports a good transport system. As well as the density, the arrangement of spaces needs to be considered to make a development pleasant. How far one is from a school, shop, park, museum, zoo, health centre, hospital will differ and should be considered against how frequently they are used and the mobility of the users. Keeping the streets animated at all times of the day and evening with different activities will help keep the vibrancy of the space. Creating spaces that people want to be in and go to is arguably more important now than it has been in the past because technology has removed the requirement to move from one’s dwelling at all. The basics of working, shopping, and entertainment can be done at home with increasing perfection as modern information technology gets better and better. This is not good for social cohesion.
21.4.3 Climate and site conditions: noise, sun path, pollution, wind and dust Information concerning climate, sun path, wind, external noise and air pollution needs to be considered to identify the potentials for passive design measures and avoiding unwanted energy loads. The climate will dictate what systems need to be put in place (heating, cooling, etc.) and when it is possible to use natural ventilation. External sources of noise, dust and pollution will create challenges to using natural ventilation. The overall light levels and sun path will inform the extent to which daylight can be used as a resource for heating and lighting and conversley needs to be avoided because of overheating and glare. Prevailing wind direction and forces will equally determine how much of this resource can be used to drive ventilation or needs to be controlled to avoid discomfort.
21.4.4 Design From these constraints one can devise ways to set out the massing of the building in terms of its orientation, height and surface area to volume.
© Woodhead Publishing Limited, 2010
Advanced building materials and eco-building design
523
Generally, thinner building plans are easier to light and ventilate naturally than thicker ones, but deeper plan floor plates are more economic and provide bigger, more useful floor areas. Light shafts, atria and courtyards can be used to break up an otherwise deep plan building. This needs to be looked at in conjunction with the other aspects such as the usage patterns, insulation and the thermal mass of the building and how the active conditioning systems (heating, ventilation, lighting, etc.) work. It is all too easy for the active systems not to take advantage of, or indeed work against, the passive systems if they are not thought about and set up correctly. For example, in a temperate climate, one could insulate a building sufficiently well such that the internal gains meet the heat losses. The thermal mass will buffer the heat gains so they can be used later. In the summer the windows can open and the thermal mass can be used to store excess heat in the day and discharge it at night. Another example is an apartment in a tropical climate occupied mainly at night, which is likely to want cooling for a few hours in the evening. In this case, thermal mass that may store the heat gain through the day when the space is empty would be counterproductive. Lightweight finishes would be able to be cooled down quickly with the active cooling system. There are a number of computer tools that will model how the building will perform (for example, Ecotect, Energy Plus and IES). While these are useful to test one’s ideas, they will not produce the design idea.
21.4.5 Documentation and delivery The design needs to be documented in such a way that it will survive the designer who may not be employed to see the system through. This is particularly true for new techniques to the industry or designs that cross conventional demarcation lines. The airtightness of a building fabric is an area that involves many different parties. Getting a window actuator to open on a command from the building management computer and the fire alarm panel requires the coordination of a number of designers, suppliers and contractors. The designer needs to consider the expertise of not only the operatives but the procurement team. Ideally the designer should be involved to see the project through but this is not always possible.
21.5
Heelis: brief case history
The National Trust UK is a charity that owns and looks after buildings and other sites of special national interest. They wanted a new headquarters building on the site of an old railway installation in Swindon. They wanted the building to advertise their commitment to sustainability. The development comprised an extensive deep plan space with mezzanines. The plan had courtyards to
© Woodhead Publishing Limited, 2010
524
Materials for energy efficiency and thermal comfort in buildings
bring light and air into the centre of the building. North lights in the roof provided daylight to the office space and roof vents acted as extracts. The north lights are shaded with photovoltaic cells that meet 10% of the electricity consumption of the building. Concrete soffits provided thermal mass on the underside of the mezzanine and roof level (Figs 21.5–21.7). The result has been very well received and performed better than expected in reducing the summertime peak temperatures. The overall success is in large part due to the client buyin to the scheme and the ongoing presence of the design team to sort out issues with the building. To maintain the reasonable peak summertime conditions, the building does swing in temperature. This was explained and the management puts out quarterly news-sheets to the staff telling them what to expect from the building to the point of invoking a ‘cardigan culture’ where one puts a cardigan on in the morning when it might be too cool for summer wear and taking it off in the afternoon. By tracking the energy and going back after the completion of the building, the designers found various issues: a damper had been wired up the wrong way around in a little used conference room, venting the hot air out in winter and shutting in the summer; the dishwasher was running continuously, wasting large amounts of hot water. These are not unusual issues in a new building. The important aspect is that they were picked up within a year and not left for the lifetime of the building. The commissioning, ongoing maintenance and operation of the building is as important as the original design and construction (Figs 21.8–21.10). South–North section S
N
E
W
East–West section
21.5 Heelis: Typical cross section showing sun path and air flow through building.
© Woodhead Publishing Limited, 2010
62°
2
1
60°
N 4 6
8
5
7
10 9
30°
© Woodhead Publishing Limited, 2010
3
Advanced building materials and eco-building design
1 Photovoltaic panels provide shading to northlights 2 ‘Snouts’ shetlter vents from rain, aid ventilation and shade east & west sun 3 Opaque insulated rooflight vents linked to BMS, allow air to ventilate to outside 4 Rooflight glazing providing good levels of daylight 5 250 mm mineral wool insulation ensures good u-values 6 Pre-cast concrete units support root finishes and provide thermal mass 7 Structural steel frame 8 Aluminium standing seam roof 9 Single ply membrane valley gutter incorporating syphonic drainage 10 Brickwork coping behind
21.6 Typical cross section showing roof construction (credit: FCB studios).
525
526
Materials for energy efficiency and thermal comfort in buildings
21.7 Photo of daylight in mezzanine (credit: FCB Studios).
21.6
Future trends
21.6.1 The drivers for more sustainable buildings Generally there are several drivers that can be used to get better buildings. The government is in control of some of them but the market and customer choice are also drivers. The legislation determines minimum standards of building performance. In the UK this is in the planning system and the building regulations. There is an onus on the designer to show that the building design complies and the construction is air tested to prove the fabric permeability rates. However, the ongoing actual performance of the building is not captured in this approach. Enforcing labelling the energy use of buildings is the next aspect of legislation. The hope is that the market will choose better building if they have the information, just as they would choose a refrigerator. There are other voluntary auditing schemes that cover a whole range of sustainable issues. BREEAM is a UK version, LEED is in the US, Greenstar is an Australian version, and ESTIDAMA is being developed in the United Arab Emirates. The corporate social responsibility agenda of organisations is driving change in companies. At worst it is a publicity exercise that is intended to cover some other corporate sins. At best it is a way of refocusing the business in
© Woodhead Publishing Limited, 2010
Total % above each temp. 6.0
Ground floor % First floor %
© Woodhead Publishing Limited, 2010
4.0 % 3.0
2.0
1.0
0.0
24
25
26
27
28
30
31
32
33
34
21.8 Graph showing percentage of annual working hours where internal and external temperatures exceed various thresholds.
527
29 Temperature (°C)
Advanced building materials and eco-building design
External temps % 5.0
528
Materials for energy efficiency and thermal comfort in buildings
21.9 Internal view of roof vent (credit: MFLLP).
21.10 Fresh air intake. The openings can be at high or low level and the openings are protected from things coming in and out (credit: MFLLP).
© Woodhead Publishing Limited, 2010
Advanced building materials and eco-building design
529
a positive manner and achieving better profit through using fewer resources, producing less waste and having happier people involved with the company. Better companies are instituting auditing processes to address these issues. The final lever is the cost of energy, water and any other resource. Clearly the more expensive the resource the greater the incentive to use less. This is manipulated by government taxation, but the market price of energy is a global commodity, can be volatile and present a cost risk to a consumer that is not of the government’s making. There is a risk that these drivers may miss the issues that are not measured directly like comfort and health. Adding draft stripping without adequate alternative measures of ventilation or humidity control could reduce the requirement for heating but create health problems for the occupants.
21.6.2 The brief for new materials Any new product should have a particular need that it fulfils. However, it needs to be accompanied with the design tools to enable designers to be able to characterise the product performance. Integration with the other elements around it needs to be resolved to avoid the interface issues and it needs to be sufficiently robust to work in a building. It has also got to be possible to build it using the skill set that is currently available or could easily be developed. Materials tend to be thought of as passive elements of buildings. They perform various functions such as supporting, insulating and making the building weather tight. They also act to buffer the temperature and humidity in a space. New material would do these tasks ‘better’. ‘Better’ in this context has a number of meanings such as easier to install, more robust, taking up less space. This would be especially the case when trying to upgrade an existing building with the occupants in situ. Another definition of ‘better’ would be one that uses fewer resources, and damages the environment less in its manufacture, installation or disposal. Often there are a number of functions needed from a façade or a building surface. Concrete is a good structural material and thermally massive. However, it is not acoustically absorbent and is not a good moisture buffer. Rooms with concrete soffits may stay cool but the acoustics and moisture may be a problem. A material that combined thermal mass, moisture buffering, acoustic absorption but reflected light would be a useful addition.
21.6.3 Dynamic materials Materials would be more useful if they had a variable or active component to them. As has been said above, there is an aim to get the need for heating down by insulating the buildings to a greater extent so that the internal gains
© Woodhead Publishing Limited, 2010
530
Materials for energy efficiency and thermal comfort in buildings
are enough to meet the heat loss in the winter. This means that the building will overheat for most of the time. If the fabric could vary its insulation value, it could manage the heat loss to keep the internal conditions stable. The same could be said of the transparency for light and solar energy, and the management and filtering of air movement though the façade. These are all functions that can be done with windows, shutters, blinds and electrochromatic glass, but there may be ‘better’ ways of doing this. ‘Better’ would include being automatically controlled and self-actuated. It might be posible for more active materials to self-clean, heal and selfassemble. Ultimately they could be used to alter the environment rather than simply buffer variations. This would mean the materials taking over the jobs of the machines, or blurring the distinction between the two. That is providing heating, cooling and lighting in the space. The external façades of buildings could be used for heat rejection and we have seen light emitting materials. Any process that uses energy will ultimately produce heat to offset heat loss. Managing the gas transfer could be done by altering the porosity of the external façade with small enough gaps to filter the air. Alternatively the gas transfer could be done selectively, moving the products of respiration (water vapour and CO2) and any other pollutants out, and oxygen in while leaving the levels of inert nitrogen the same inside and out. These active processes will require energy and a complete system would collect its own from the sun and wind around the buildings.
21.6.4 The living world The systems described in the previous section describe the living world where all these functions are present. There is environmental control, selfassembly, energy collection, storage and distribution. The materials are all recyclable. The systems are finely tuned and very sophisticated. The roots of a tree use a comparatively small amount of material compared to conventional foundations and piles. One cannot help notice that the trees are left standing after an earthquake has levelled the buildings around. The living world has structure, insulation, gas transfer, movement and even bioluminescence. The greatest challenge is to harness these technologies and engineer them more directly for our own use. The relationship between plants and buildings has been that they are best kept apart as one tends to damage the other. We are used to using dead products such as wood or leather but not living ones (Fig. 21.11). This could start with using plants for shading or cooling the external façade of the building. In temperate climates a deciduous plant will drop its leaves in the winter and allow more heat and light in than in the summer when the leaves are out. Where it will end is more in the hands of genetic engineers and cancer researchers as much as the material scientist of today.
© Woodhead Publishing Limited, 2010
Advanced building materials and eco-building design
531
21.11 Plants in buildings: threat or opportunity?
21.7
Sources of further information and advice
∑ A timeless view of how to run a building contract based on the construction of a 1930s suburban house: The Honeywood File: An Adventure in Building, HB Creswell. ∑ Modelling software packages: Ecotect, IES, Energy Plus. ∑ Design guidelines: The CIBSE guides: Available from The Chartered Institution of Building Services Engineers, 222 Balham High Road, London. ∑ Health issues in building services: CIBSE TM40: January 2006, The Chartered Institution of Building Services Engineers, London. ∑ US government aid provider’s view on how to deal with climate change in developing countries: Adapting to climate variability and change. A guidance manual for development planning. Available from http://www. usaid.gov/our_work/environment/climate/docs/reports/cc_vamanual.pdf. Accessed August 2009. ∑ An architectural review of the possibilities of working with living materials: Neoplasmatic Design: Architectural Design, November–December 2008, vol. 78 no. 6, guest editors Marcos Cruz and Steve Pike, Wiley.
21.8
References
Alexandri, E. and Jones, P. (2008) Temperature decreases in an urban canyon due to green walls and green roofs in diverse climates, Building and Environment 43(4), 480–493. © Woodhead Publishing Limited, 2010
532
Materials for energy efficiency and thermal comfort in buildings
Anon (a) Website produced by Strathclyde University. Available at: http://www.esru. strath.ac.uk/EandE/Web_sites/01-02/RE_info/hec.htm (accessed August 2009). Anon (b) UK Environment agency guidance on the benefits of green roofs. Available at: http://www.environment-agency.gov.uk/business/sectors/91970.aspx (accessed August 2009). Bouchlaghem, K., Nsom, B., Latrache, N. and Haj Kacem, H. (2009) ‘Impact of Saharan dust on PM10 concentration in the Mediterranean Tunisian coasts’, Atmospheric Research 92(4), 531–539. Building Bulletin 93 Acoustic Design of Schools, A Design Guide, Department for Education and Skills, UK, 2003. Building Bulletin 101 Ventilation of School Buildings, Department for Children, Schools and Families, UK Version 1.4, 5 July 2006. DEFRA 2009a UK government statistics. Available at: http://www.defra.gov.uk/sustainable/ government/progress/national/16.htm (accessed August 2009). DEFRA 2009b Accounting for the Effects of Climate Change, June 2009. Supplementary Green Book Guidance. Produced by HM Treasury and Department for Environment Food and Rural Affairs. Available at: http://www.defra.gov.uk/environment/climatechange/ adapt/pdf/adaptation-guidance.pdf (accessed August 2009). Loh, M. and Coghlan, P. (2003) Domestic Water Use Study in Perth, Western Australia, 1998–2001. Available at: http://www.energyrating.gov.au/library/pubs/wa-wateruse. pdf (accessed August 2009). MacKay, D. (2008) Sustainable Energy – Without the Hot Air. Available at: http://www. withouthotair.com/ (accessed August 2009). McKinsey Global Institute (2008) The Carbon Productivity Challenge: Curbing Climate Change and Sustaining Economic Growth, Page 14, Exhibit 5. Available at: http:// www.mckinsey.com/mgi/publications/Carbon_Productivity/index.asp (accessed June 2009). National Atmospheric Emissions Inventory, UK. Available at: http://www.naei.org.uk/ pollutantdetail.php?poll_id=24&issue_id=1, http://www.naei.org.uk/pollutantdetail. php?poll_id=24 (accessed July 2009). Regional Air Pollution in Developing Countries, Sweden. Available at: http://www.sei. se/rapidc/emissions.htm (accessed June 2009). Statutory Instrument 1989 No. 1790, The Noise at Work Regulations 1989. Available at: http://www.opsi.gov.uk/si/si1989/Uksi_19891790_en_1.htm (accessed June 2009). US DOE Buildings Energy Data Book: 1.1 Buildings Sector Energy Consumption Section 1.1.3 Buildings Share of U.S. Primary Energy Consumption (Percent). Available at: http:// buildingsdatabook.eren.doe.gov/docs/xls_pdf/1.1.3.xls (accessed August 2009). US EPA website on air pollution. Available at: http://www.epa.gov/air/airtrends/aqtrnd95/ pm10.html (accessed July 2009). Wikipedia (a) Article about Prius car. available at: http://en.wikipedia.org/wiki/Toyota_ Prius#EV_mode (accessed August 2009).
© Woodhead Publishing Limited, 2010
22
Materials for energy efficiency and thermal comfort in domestic buildings
A. P e a c o c k, Heriot Watt University, UK
Abstract: There are more than 22 million dwellings in the EU27 and approximately 8 million dwellings in USA and Canada that were built before 1919. A large proportion of these are likely to be of uninsulated solid wall construction. The UK has between 5.5 and 7.3 million solid wall dwellings. They are potentially responsible for almost 50% of the total CO2 emissions attributable to the UK housing stock with heat loss through the solid wall the primary cause of these emissions. Architectural vernacular barriers to the adoption of external wall insulation have perhaps been overstated as less than 25% of solid wall dwellings are in conservation zones in the UK. Technologies and systems based on conventional insulation materials have been available in the marketplace for the past three decades. The carbon payback for these systems is less than 2 years but the economic payback computed using whole life cycle costing metrics is decades in length. Alternative legislative and policy approaches are needed to stimulate this marketplace as the achievement of national emission targets are unlikely if this technology is excluded as a consequence of perceived economic or socio-cultural barriers. Key words: energy efficiency, solid wall dwelling, external insulation, market statistics.
22.1
Introduction
It is widely recognised that if the EU is to meet its CO2 emission reduction targets in the coming decades then the energy efficiency of the existing housing stock will have to be improved dramatically (Levine et al., 2007). A particular problem is the prevalence of solid wall dwellings in the stock. This chapter aims to provide some degree of quantification of the scale of the challenge in terms of numbers of dwellings. It then goes on the consider the situation in the UK in particular to quantify the contribution of solid wall dwellings to housing stock and national CO2 emissions. Existing solutions to address solid wall fabric heat loss applicable to the UK are then considered from the perspective of carbon payback, the market, the householder and the cost. Conclusions are reached which may have relevance to where materials research might be necessary in the future.
533 © Woodhead Publishing Limited, 2010
534
Materials for energy efficiency and thermal comfort in buildings
22.2
EU domestic housing stock
There were reported to be approximately 166 million dwellings in the EU27 in the year 2000 (UNECE, 2006). Of these, 50% were located in three countries: Germany (22%), UK (14%) and France (14%) (Fig. 22.1). The housing stock in each country can be disaggregated by age of construction to reveal quite disparate results depending on the country considered (Fig. 22.2). For instance, the proportion of the existing national housing stock built before 1919 was highest in Denmark (21%) and lowest in Greece (3%). Interestingly, figures for North America show that approximately 8% of the existing housing stock was built before 1919. Translating these raw statistics into construction type is made difficult by the transition of architectural vernacular adopted in each country. This was found to be quite disparate. For instance, in Denmark the conventional wall construction method changed from uninsulated solid wall to uninsulated twin leaf cavity around 1930 whereas in Greece this transition occurred in 1960 (Balaras, 2003). Similarly, the transition from uninsulated to insulated cavity wall occurred around 1950 in Denmark compared to 1980 in Greece.
22.3
UK domestic housing
The UK domestic sector is responsible for 27% of total CO2 emissions and 28% of primary energy use in 2006 (DEFRA, 2009). Primary energy
Greece 2%
Portugal Austria Denmark 2% 1% 2%
Hungary 2%
Others 5%
Germany 22%
The Czech republic 2% Belgium 2% Sweden 2% The netherlands 4% Poland 7%
United kingdom 14%
Spain 7%
Italy 12%
France 14%
22.1 Total dwellings in the EU27 disaggregated by country.
© Woodhead Publishing Limited, 2010
<1919
1919–1945
1946–1970
1971–1980
>1981
45
National housing stock (%)
35 30 25 20 15 10 5
United Kingdom
Sweden
Spain
Poland
The Netherlands
Italy
Greece
Germany
France
Denmark
0 Austria
© Woodhead Publishing Limited, 2010
40
Materials for energy efficiency and thermal comfort
50
22.2 Dwellings in some EU countries disaggregated by location and age of construction.
535
536
Materials for energy efficiency and thermal comfort in buildings
consumption has risen by approximately 20% since 1970 (BERR, 2009). Energy intensity per household has fallen by approximately 11% whereas the number of households has risen by 40% over the same time period (DEFRA, 2009). The predominant cause of energy consumption (and subsequent CO2 emissions) is space heating energy (BERR, 2009). This was responsible for approximately 58% of total domestic sector primary energy use and 47% of total domestic sector CO2 emissions (BERR, 2009). Clearly, then, the development of a strategy that leads to a reduction of between 36 and 42% in national CO2 emissions by 2020 and an 80% reduction by 2050 (DEFRA, 2008) are only likely to be successful if they encompass pathways that lead to a reduction of domestic space heating demand.
22.3.1 The stock
Number of households (’000)
In 2007 there were approximately 25.5 million households in the UK; 21.2 million in England, 2.3 million in Scotland, 1.3 million in Wales and 0.7 million in Northern Ireland. It is possible to disaggregate these by age and type of dwelling (Fig. 22.3) (DCLG, 2008). Some 64% of the housing stock was built in three distinct periods; 1919–44, 1944–64, 1964–80. In the relatively recent past, then, there have been three distinct booms in housebulding largely associated with population growth, post-war renewal and slum clearance (Hinnels, 2006). Disaggregation by age and type of dwelling is important as it begins to allow analysis of the range in constructions prevalent in the stock. The two principal construction methods for housing in the UK are solid masonry and pre-1900
1900–1918
1964–1980
1981–1996
1919–1944
1945–1964
2500 2000 1500 1000 500 0 Semidetached
Detached
End terrace
Mid terrace
Purpose built flat
Converted flat
22.3 UK domestic stock disaggregated by age of construction and type of dwelling.
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
537
cavity masonry. It is reported that these account for approximately 6.6 million (26%) and 12.6 million (49%) homes in the UK respectively (BRE, 2008; Shorrock and Utley, 2003). An alternative study considered the range of solid wall dwellings in the UK as being between 5.9 and 7.3 million dwellings (Pett, 2001). Estimating these proportions is a non-trivial task, made so by the relatively slow transition from solid wall to cavity wall that took place largely in the first half of the 20th century. The first recorded example of a cavity wall involving wall ties (as opposed to bonded bricks) was in the Isle of Wight dating from the 1840s (Lewis, 2009). Cavity wall construction became commonplace in the 1930s and effectively became mandatory after the 1965 Building Regulations (Pett, 2001).
22.4
Building fabric heat loss and CO2 emissions
It is interesting to compute the heat loss characteristics of different wall constructions so that the proportion of total CO2 emissions arising from heat loss through the external wall of a dwelling can be estimated. From this, the importance of reducing heat loss through external walls can be explored relative to the overall CO2 emission reduction targets discussed earlier. The heat loss characteristics of a wall can be modelled using, for instance, knowledge of the construction method coupled to the standard U-value calculation approach (Anderson, 2006). However, it has been reported that the measurement of in situ U-value of solid walls generally produces lower values than those computed in the manner described. A recent study for Historic Scotland, for instance, found substantial variation depending on the internal finishing (Table 22.1) (Baker, 2008). This is not unexpected if one considers the variation in air voids that will be created by the construction detailing. In addition to the transition from solid wall to cavity alluded to earlier, domestic sector construction methodology has undergone change as a consequence of changes to the building regulations. Since the OPEC crisis of 1973 the focus of this regulation has been on reducing the heat loss characteristics of new dwellings with this emphasis accelerating over the last 15 years. The effect of the changes in regulation on heat loss characteristics of a typical detached, semi-detached and terraced dwelling (112m2, 20% glazing ratio) were computed using steady state computer models developed Table 22.1 In-situ measurement of solid walls 600 mm masonry walls – internal finish description
U-value range (W/m2·K)
Wall plastered on the hard Wall with lath and plaster Wall with plasterboard
1.5 ± 0.4 1.0 ± 0.3 0.9 ± 0.1
© Woodhead Publishing Limited, 2010
538
Materials for energy efficiency and thermal comfort in buildings
for the TARBASE research project (Peacock et al., 2007) (Fig. 22.4). The data for the dwellings as if built to Nordic regulations (much of which has been in place since the mid-1970s) is shown by comparison. The heat loss characteristics of the solid wall dwellings can be five and six times that of a dwelling built either to Nordic or more recent UK standards. This has a substantial effect on the CO2 emissions attributable to the dwelling. It is possible to estimate the extent of this effect using the domestic stock model developed by the Environmental Change Institute for the Building Market Transformation research project (Hinnels, 2006). Between 27 and 47% of total domestic sector emissions can be attributed to solid wall dwellings in the UK dependant on the transition of prevalent construction technology adopted by the UK construction industry (Fig. 22.5). It is possible to quantify the extent to which emissions arising from the occupation of solid wall dwellings are predicted on replacing the heat lost through the solid wall. For instance, for a detached dwelling with a wall U-value of 1.5W/m2·K, a natural gas-based heating system and ownership and usage factors for appliances typical of a family of average income with two children, the proportion of total household emissions attributable to heat loss through the wall is approximately 30–40% depending on the treated floor area (Fig. 22.6). A similar exercise can be performed for semidetached (25–35% of total CO2 emissions associated with heat loss from Detached
Semi-detached Terraced
250 200 150 100 50
Sweden
Norway
Denmark
2007 regulations
2005 regulations
2001 regulations
1995 regulations
Filled cavity
Clear cavity
0 Solid wall
Heat loss through wall (W/K)
300
22.4 Effect of wall construction and insulation level on the heat loss characteristics of a detached, a semi-detached and a terraced dwelling of treated floor area 112 m2.
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort CO2 emissions attributable to solid wall dwellings
539
CO2 emissions attributable to other constructions
All pre-1919 All pre-1945 dwellings dwellings
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 CO2 emissions attributable to the UK domestic sector (MTCO2)
Proportion of total dwelling CO2 emissions (%)
22.5 Proportion of total UK domestic sector emissions that is attributable to dwellings of solid wall construction. 45
40
35
30
25
20
0
50
100
150 200 250 Treated floor area (m2)
300
350
400
22.6 Proportion of dwelling CO2 emissions attributable to heat loss through the external wall.
the wall) and a terraced property (20–30% of total dwelling CO2 emissions associated with heat loss through the wall). These ratios can be applied to the stock model exercise indicated above to estimate that approximately 2–5% of total UK CO2 emissions could be attributed to the energy required to replace the heat that is lost through solid walls of dwellings in the UK. It should be stressed that this figure should be taken as a guide only but it is interesting to frame data in this manner as it allows different narratives
© Woodhead Publishing Limited, 2010
540
Materials for energy efficiency and thermal comfort in buildings
to be explored. For instance, placing this figure in some perspective, this is somewhere between 8 and 25% of the CO2 emissions arising from UK coal-fired electricity production in 2007 (BERR, 2009). It is a substantial figure and addressing its scale through supply side measures would be extremely challenging. It would seem likely that if the UK domestic sector is to contribute towards the reduction in CO2 emissions enshrined in the Climate Change Bill (DEFRA, 2008), then measures that address this solid wall construction will have to be developed, marketed and promoted.
22.5
Architectural vernacular
The ability to treat solid wall dwellings is compromised to some degree by their historical and (by extension) cultural importance. The conservation movement was initiated in the UK by William Morris who founded the Society for the Protection of Ancient Buildings in 1877. His aim was to ‘treat our ancient buildings as monuments of a bygone art, created by bygone manners, that modern art cannot meddle with without destroying’ (SPAB, 2009). The ethos encapsulated in this statement was initially applied to institutions or the land-owning class but over almost a century it diffused to address all aspects of architectural heritage as witnessed by the legislative creation in 1968 of conservation areas. There are approximately 14 500 conservation areas in the UK (CIPFA, 2001). The description of a conservation area is those areas that have a ‘Special architectural or historic interest, the character or appearance of which it is desirable to preserve or enhance’ (OPSI, 1990). It has been estimated that 1.2 million dwellings are located in conservation areas in the UK (Bottrill, 2005). If we consider the ethos and descriptions of conservation areas, it is reasonably safe to assume that the vast majority of them will be considered with pre-1919 housing. Whilst a number of these may have used other construction methods (e.g. timber frame), it is thought that the majority would be of solid masonry construction. To simplify matters, if it is assumed that all 1.2 million dwellings contained within conservation areas are of solid masonry construction, then this would constitute 13% of all solid masonry dwellings or approximately 5% of all UK dwellings. A market barrier that is often quoted with respect to the uptake of external wall insulation in the UK is planning issues associated with the preservation of specific architectural vernacular. Whilst this may represent an insurmountable problem for a number of properties, the substantial majority of solid masonry dwellings would not appear to be encumbered by this specific barrier. It is also relevant to consider the purpose of the legislation; ‘May form groups of buildings, open spaces, trees, historic street patterns, village greens or features of historic or archaeological interest. It is the character of the areas rather than individual buildings, that Conservation Areas seek to enhance’ (DCLG, 1994). It would seem to be related therefore to the mood, feeling
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
541
and character of the public architectural space defined within a particular conservation area. This public space need not necessarily be concerned therefore with modifications to the rear of the dwelling. It is thought, for instance, that as much as 60% of the total building envelope of a Victorian terrace is at the rear of the dwelling (Lowe, 2006).
22.6
Intervention strategies
With solid masonry construction there are two clear pathways to achieving a reduction in fabric heat loss, namely internal and external wall insulation. Ignoring the relative effects of each approach on the thermal performance of a dwelling for a moment, it is useful to explore the impact of solid wall insulation in comparison with other technological intervention strategies possible in individual dwellings. A range of different strategies are possible with, for instance, the UK utility supplier obligation (OFGEM, 2008) potentially offering a choice of 17 different interventions for a single dwelling. The TARBASE research project was a £1.4 million research project that was conducted between 2004 and 2009 and was part of the Carbon Vision Buildings suite of projects (TARBASE, 2009). The aim of project TARBASE was to model technological solutions (end use equipment, building fabric, heating, ventilating and air conditioning (HVAC) and supply side) which would allow a radical, visible, step change input to policies and programmes designed to reduce the CO2 emissions attributable to the existing UK building stock by 50% by 2030. A range of different domestic building types were studied among which was a solid wall detached dwelling (Peacock et al., 2007). A series of bespoke models were developed throughout the research project to estimate the CO2 emission saving potential of different interventions, both singularly and in conjunction with other improvements. The relative importance of external wall insulation when compared with a range of other measures that could potentially be applied to the solid wall detached dwelling is shown in Fig. 22.7. If applied to 80% of the external wall, it outperforms all the technologies considered in Fig. 22.7. Even if applied to only the rear of the dwelling, external wall insulation has a greater impact on CO2 emissions for this dwelling than all other interventions other than 30 m2 of PV and 3kW micro-combined heat and power (mCHP) systems based on fuel cell technology (that is unproven and yet to reach the market). The ability of this dwelling to achieve deep cuts in CO2 emissions will clearly be compromised by the absence of external wall insulation. The individual measures shown in Fig. 22.8 were bundled together to form intervention sets for the solid wall detached dwelling. This assessment accounted for both the synergistic and antagonistic effects associated with combining interventions (in so much as they would be present).
© Woodhead Publishing Limited, 2010
542
Materials for energy efficiency and thermal comfort in buildings
Emission reduction (% of 2005 baseline)
30
Heat saving interventions
25
Electricity saving interventions
Supply side interventions
25.4
20
21
18.4
15 12.6
2.4 2.6 LIghting (CFL)
4.3
4.1 88% efficient boiler
3.2
Other appliances
3.3 4
Increased loft insulation
5
Infiltration reduction
8.8
10
7
6.5 2.8
2.3
Micro-CHP systems
Solar water heating
3.9 kWp PV (30 m2)
1.3 kWp PV (10 m2)
3 kW 30% efficient
1 kW 30% efficient
1 kW 15% efficient
Refrigeration
MVHR
Glazing
External insulation – rear of dwelling External insulation – 80%
0
Solar-PV systems
22.7 CO2 savings attributable to a range of different technological intervention strategies as applied to a detached solid wall dwelling of treated floor area 144 m2. 80% External wall insulation No external wall insulaton Emission reduction (% below 2005 baseline)
100 90 80 70 60 50 40 30 20 10 0
2050 target
2020 target
Demand side only
Demand side + boiler
Demand side + boiler + solar water heating
Demand Demand Demand side + boiler side + side + + solar water boiler + boiler heating + solar water + solar heating + decarbonised water decarbonised electricity grid + extant heating + electricity climate grid solar PV change
22.8 Deep cut technological intervention sets with and without external wall insulation applied to the detached solid wall dwelling of 144 m2 treated floor area.
In the absence of external wall insulation, the 2020 targets could only be achieved by an intervention set comprising all the remaining heat saving fixes, the electricity saving fixes on all lights and appliances, solar water heating
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
543
and 10 m2 of solar-PV. The 2020 target could be exceeded if the effect of extant, near-term climate change on reducing the intensity of the domestic heating season were accounted for. If the UK electricity infrastructure was successful in deploying 18 GW of network scale wind, 5 GW of coal plant with carbon capture and storage (CCS) technology and maintained 10 GW of nuclear capacity, it is feasible that an annual average grid emission factor (GEF) of 0.28 kgCO2/kWh may be achieved (compared to 2005 GEF of 0.52 kgCO2/kWh). If this potential externality was applied to the pre-1900 detached dwelling with demand side measures, boiler improvement, solar water heating and reduced heating season as a consequence of extant climate change, then the savings attributable to the dwelling would be approximately 49%. However, it seems fanciful that the 2050 target could ever be achieved for this dwelling if external wall insulation were not included in the package of measures. The role of some form of solid wall insulation would seem to be paramount if the emissions-saving targets enshrined in the Climate Change Bill are to be met. This underlying conclusion is given greater weight by consecutive reports from IPCC which have confirmed with high agreement and much evidence that ‘energy efficiency measures in buildings can achieve substantial reductions in CO2 emissions using mature technologies that already exist widely and that have been successfully used’ (Levine et al., 2007). With solid masonry construction there are two evident pathways to achieving a reduction in fabric heat loss, namely internal and external wall insulation.
22.7
Internal wall insulation
The application of insulation to the internal face of the external wall has benefits in that the external appearance of the dwelling is unchanged. It therefore deals neatly with the issues associated with preservation of architectural vernacular. However, its deployment raises certain key issues associated with thermal mass. Internal insulation isolates the thermal mass of the wall from the internal space. Any internal gains or solar gains that are permitted into or are generated in the internal space will in effect be trapped by the insulating layer and their dissipation can only be achieved by the adoption of some form of ventilation schedule. These gains may be useful in offsetting heating loads during the heating season. However, they may also contribute to increased instances of overheating. A useful description of thermal comfort is that action taken by an individual to maintain their perception of a comfortable environment. This action may involve behavioural and/or technological adaptation. Issues of overheating in UK dwellings may seem an opaque concept but there is some evidence to suggest that near-term, extant warming of the UK climate may precipitate a domestic cooling season. It is thought that early
© Woodhead Publishing Limited, 2010
544
Materials for energy efficiency and thermal comfort in buildings
market growth in domestic air conditioning systems may be driven by distress purchasing during extreme events, for example the 2003 heat waves (Wright et al., 2005). There is, however, evidence from the United States to suggest that the eventual market saturation level of domestic air conditioning will be determined not by extreme events but by cooling degree days (Sailor and Pavlova, 2003). It is possible to apply the relationships developed in the US to predict the eventual prevalence of domestic air conditioning in the UK. When cooling degree days were computed using a base comfort temperature of 18.3 ∞C, no market for domestic air conditioning in Edinburgh and London was found when the 2005 CIBSE TRY climate files were used in conjunction with these algorithms. It is possible to morph the CIBSE TRY climate files using UKCIP02 algorithms to produce climate files that are indicative of those that might be expected in the time slice 2010–40, i.e. near term (Belcher et al., 2005; UKCIP, 2009). When these morphed climate files were used, a saturation level of 0.18, i.e. air conditioning would be installed in 18% of homes, was found for London. No market evolved for Edinburgh. If the action of UK householders to maintain thermal comfort as a consequence of near-term climate warming mimics the response of householders in the US, then in London alone 550 000 homes will install air conditioning equipment. The energy demand of domestic air conditioning systems has been estimated as being between 6 and 15 kWh/m2 p.a. (He et al., 2005). If applied to the whole house this would be between approximately 550 and 1400 kWh per annum although most systems would be expected to be constrained to specific areas of the dwelling, e.g. living room and bedroom. Perhaps of greater concern than the rise in energy consumption, however, is the psychological or cultural message encapsulated in the widespread adoption of another energy consuming technology within the household at precisely the time when strategies are being developed to decarbonise service provision. This debate has been explored, for instance, by Wilhite who suggested that domestic appliances contain behavioural scripts, i.e. they alter the behaviour of the occupants in unforeseen ways (Wilhite, 2007). One example of this might be the effect of the volume of refrigerated space in the home on food consumption behaviour and the consequent area of chilled space in supermarkets. Another (and one to which Wilhite alluded) was that the behavioural scripts contained within domestic air conditioning systems may have contributed to the dominant role of the passenger car in the US transport network. The certainty of extant climate change means that the single focus of building fabric mitigation strategies can no longer be to reduce CO2 emissions. Rather, any building fabric strategy has to have two unquenchable aims: (a) to be an adaptation strategy that is cognisant of extant, near-term climate change and does not compromise (indeed should aid) the capacity of the dwelling to achieve desired levels of thermal comfort by passive means
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
545
during the summer months, and (b) reduces CO2 emissions attributable to the provision of services (heat, laundry, cooking, etc.) to the dwelling. For this reason alone, the widespread adoption of internal wall insulation without concurrent adoption of an appropriate and adequate ventilation strategy is likely to be a retrograde step, particularly in the south of the UK where these adaptation pressures are going to be most keenly felt.
22.8
External wall insulation
22.8.1 Market statistics It is estimated that the solid wall insulation market is valued at £91 million at contractors’ prices (EST, 2008). This was reported to be split evenly between external and internal wall insulation. This data was reported to include domestic, commercial and industrial buildings. The total number of solid wall insulation installations is estimated to be 16 000 new builds and 17 500 retrofits per year (33 500 solid wall insulation installations in total). It is possible to make a series of assumptions to estimate the size the market will have to grow to in order that an external wall insulation intervention strategy might contribute towards the UK CO2 emission reduction targets. If we assume the number of solid wall dwellings to be between 5.5 and 7.3 million. If we further assume that 1.2 million of these dwellings are not suitable for external wall insulation because of planning restrictions. This leaves between 4.3 and 6.1 million dwellings. If we were to assume that external wall insulation was to be taken up over the decade 2010–20 in the target market, then the industry might be expected to accommodate between 430 000 and 790 000 installations per annum. However, it is likely to be higher than this – unless the uptake of the technology is mandated through legislation. If the uptake of the technology is to some degree market led, it is likely to follow some variation of a classic diffusion model as proposed by Rogers (2003). Rogers defined five societal groups who are involved in the adoption of a technology at different stages. Taking a somewhat idealised approach, the proportion of the population that will fall into each category can be estimated (Table 22.2). These proportions can then in turn be applied to the number of solid wall dwellings in the UK – assuming that these groups will be distributed proportionately in this construction. Assuming that it may take five years to move through the first two classes, this would leave five years to 2020 to reach the early, late majority classes. This would represent installations of between 600 000 and 1000 000 per annum. It is clear that the current level of market activity (17 500 retrofit including domestic, commercial and industrial) is nowhere near equivalent to either of
© Woodhead Publishing Limited, 2010
546
Materials for energy efficiency and thermal comfort in buildings
Table 22.2 Number of solid wall dwellings disaggregated by rogers’ societal groupings Number of dwellings (000’s) Group Proportion (% of population)
Total number of solid wall dwellings = 4.3 million
Total number of solid wall dwellings = 6.1 million
Innovators Early adopters Early majority Late majority Laggards
108 581 1462 1462 688
152 823 2074 2074 976
2.5 13.5 34 34 16
these approaches. Even if this level of market activity was wholly domestic, it would take between 246 and 451 years to reach 100% market saturation.
22.8.2 System types There are 33 different external wall insulation systems from 10 companies that are registered on the INCA website and that have received certification for use as a building product, e.g. by the British Board of Agrément (Table 22.3) (INCA, 2009). These systems differ in specific details of their fixing (insulation to substrate and render to insulation) but can also be disaggregated by (a) their applicability to different construction methods, (b) the insulation material used and (c) the finishing material offered. The concept of technology maturity alluded to in the IPCC document is emboldened if one considers the modal certification date for these systems is 1996 with some systems having been in use since the 1970s. Conventional insulation materials are used, with thicknesses of 15 mm to 140 mm offered (Table 22.3).
22.9
Carbon payback time
CO2 emissions are embodied in any technological intervention that may be deployed to reduce the operational CO2 emissions of a dwelling. It is important to consider the time period taken for the operational CO2 savings to exceed the CO2 embodied in the intervention. This can be termed the carbon payback of the intervention. To explore this using the conventional insulation materials shown in Table 22.3, a simple, generic external insulation system was specified (Fig. 22.9). This shows a series of timber dabs fixed to the substrate which effectively form an air gap between the substrate and the insulation. The insulation board is subsequently fixed to the dabs. The supporting mesh and cementitious render are for simplicity shown as a contiguous layer. The core material properties of the four conventional
© Woodhead Publishing Limited, 2010
Table 22.3 Certified external insulation systems in the UK (INCA, 2009)
Basic 1 Basic 2 Basic 5 Ecomin 200 Ecomin 300 Ecomin 500 Basic 1 Rail Ecomin 200 rail
BBA BBA BBA BBA BBA BBA BBA BBA
Alumasc Ltd www.alumasc- exteriors.co.uk
Swisslab Swistherm
Finish
X X
X X
X X
X X X X X
BRC Special Products Thermalath www.brc-special- Polylath products.co.uk Inulath Rendalath EPS
BBA BBA BBA BBA
X X X X
X X X X
X X X X
X X X X X X X X
X X X X
X X X X
Dryvit UK Ltd Outsulation www.dryvit.co.uk Roxsulation
BBA 98/3548 BBA 98/3548
X X
X X X X
96/3242 96/3242 96/3242 96/3242
X X X X
X X
X X X X
X X X X X X
Dash
X X
Brickslip
X X
Silicone
X X
Acrylic
BBA 92/2914 BBA 00/3766
Mineral
X X X X X X X X X X X X X X X X X X X X
Polyurethane
X X X X X X X X X X X X
Phenolic
X X X X X X X X X X X X
Expanded PS
X X X X X X X X
Extruded PS
X X X X X X X X
Mineral wool
X X X X X X X X
Steel frame
X X X X X X X X
96/3238 96/3238 96/3238 96/3247 96/3247 96/3247 96/3248 96/3247
X
X
X X X X
547
Timber frame
Alsecco (UK) Ltd www.alsecco.co.uk
Insulant
Masonry
Substrate
Concrete
Certifying body
SIP
System name
Materials for energy efficiency and thermal comfort
© Woodhead Publishing Limited, 2010
Company
548
Table 22.3 Continued
BBA 90/2347
X
X
X
X
X
X
Structherm Ltd Structural Cladding www.structherm.co.uk NSC 2 NSC 3 NSC 5
BBA BBA BBA BBA
03/4022 96/3243 96/3243 96/3243
X X X X
X X X X
X X X X
X X X X
X X X X
X X X X
X X X X
X X X X
X X X X
X X X X
X X X X
X X X
Weber (Formerly Expomesh) www.netweber.co.uk Weber .therm XL (formerly Expolath)
BBA 91/2692 IAB 06/0260 BBA 91/2600 IAB 07/0295
X X X X
X X X X X X
X X X X
X X X X
X X X X
X X X X
X X X X
X X X X
X X X X
X X X X
WBS www.wbs-ltd.co.uk
BBA 99/3564 ETA/DIBT X
X X X X X X X X
X
Rockwool www.rockwool.co.uk
Rockshield
Thermaloc Heck Silicone System
X X X
X X X
X X X
X X X
X X X
X X X
X X X X X X
X X X
X X X
X X X X X X
X X X
X X X X
Dash
Silicone
X X X
Acrylic
X X X
Mineral
X X X
Phenolic
X X X
X X X
Extruded PS
X X X
Powerwall External Wall System 1 BBA 95/3090 Systems Ltd External Wall System 2 BBA 95/3090 www.powerwall.co.uk External Wall System 3 BBA 95/3090
Mineral wool
X X X X X X X X X X X
Steel frame
X X X
Masonry
BBA 87/1800 BRE 029/95 BRE 041/97
Brickslip
Finish
Polyurethane
Permarock Permarock Permarock
Insulant Expanded PS
Permarock www.permarock.com
Timber frame
Substrate
Concrete
Certifying body SIP
System name
Materials for energy efficiency and thermal comfort in buildings
© Woodhead Publishing Limited, 2010
Company
Materials for energy efficiency and thermal comfort
549
Render (10 mm) Insulation (X mm) Air gap (10 mm) Sandstone (600 mm) Air gap (10 mm) Lath and plaster (12 mm)
22.9 Generic build-up of a wall encompassing an external insulation system. Table 22.4 Properties of insulation material commonly used in external wall systems Insulation material
Thermal Density conductivity (kg/m3) (W/m·K)
Embodied carbon (kgCO2/kg)
Mineral wool Expanded polystyrene Phenolic Polyurethane
0.04 0.03 0.02 0.03
1.20 2.50 2.53 3.00
105 25 30 30
insulation materials are given in Table 22.4 – expanded and extruded polystyrene are assumed to have the same physical properties. The effect of deploying the generic wall insulation system on the operational CO2 emissions of the aforementioned detached pre-1900 dwelling with the properties assumed in Table 22.5 was computed. The thickness of the external insulation material was varied to achieve whole wall U-values in the range 0.1 to 0.6 W/m2·K. The embodied carbon contained in the external wall system was simplified to include only the embodied CO2 emissions of the insulation material and the cementitious render. The embodied CO2 emissions for each of the insulation materials and the finishing render were taken from the ICE database (Hammond and Jones, 2006). The carbon payback for the generic external wall system deployed to achieve a range of different U-values for the external wall of the pre-1900 detached dwelling was computed according to Eq. 22.1.
PBCO2 = EE-I/EO
22.1
where PBCO2 is carbon payback (months), EE is embodied CO2 emissions of © Woodhead Publishing Limited, 2010
550
Materials for energy efficiency and thermal comfort in buildings
Table 22.5 Three-bedroomed, pre-1900 detached dwelling – fabric and occupancy Property
Condition
External footprint Initial wall U-value Glazing and door ratio Net external wall area External wall area available for external wall insulation Location Whole house internal temperature Occupants
144 m2 1.6 W/m2·K 22% 173 m2 80% of net external wall
Edinburgh 20.4 ∞C Family of four – 2 adults working, 2 children at school. This defined for instance appliance usage and ownership and building occupancy Heating system Natural gas fired boiler, hydronic Seasonal boiler efficiency 88% CO2 emission factor for natural gas 0.19 kgCO2/kWh
the insulation and render layers, and EO is operational CO2 emissions saved as a consequence of deploying the external wall system. The carbon payback of all the external wall insulation systems was less than 2 years regardless of the resultant U-value achieved (Fig. 22.10). Given that the warranty offered on the majority of the systems shown in Table 22.3 is in the region of 20–30 years, this would seem to represent a rational outlay of initial CO2 emissions for the longer term.
22.9.1 Whole life cycle costing The calculation of whole life costs was based on a discounted cash flow analysis of the costs and revenues associated with the investment in external wall insulation over a selected period of time (Masini et al., 2010). External wall insulation leads to a decrease in energy consumption and therefore expenditure on utility bills. The only economic benefit that is applied to the deployment of external wall insulation is the reduction in utility bills. Any other benefits (for instance, enhanced asset value) are ignored. The costs incurred by the deployment of an external wall system were assumed to be (a) the initial capital cost, (b) anticipated maintenance costs of the intervention, and (c) energy costs of the dwelling over a nominal 25-year study period (2005–30). This seemed a reasonable time frame as defined by the warranty attracted by the installation of an external wall system. The pre-1900 detached dwelling described in Table 22.5 was used in this exercise. The selection of discount rate is a key variable in defining the net present value (NPV) of an investment and its assignment is a matter of some contention. While it is reported that studies evaluating energy efficiency
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort Mineral wool
EPS
Phenolic
551
PU
Carbon payback time (months)
50 45 40 35 30 25 20 15 10 5 0
0
0.1
0.2 0.3 0.4 0.5 Resultant U-value of wall (W/m2·K)
0.6
0.7
22.10 Carbon payback time of external wall insulation systems with different insulation materials as applied to the solid wall detached dwelling.
technology typically use a discount rate of 4–8%, the discount rate used here was 3.5%, as this is the discount rate recommended by the UK Treasury in the appraisal of any investment in the public sector (Geller and Attali, 2005; HM Treasury, 2003). The whole life cost of the interventions proposed and the base case scenario for this study is represented by the generic WLC equation: ∑ ∑ ∑ ∑ ∑ ∑
WLC = C + APV + MPV + EPV + RPV
22.2
C is the capital cost which includes the initial investment for the external wall insulation and the system design (this will be equal to zero for the base case). A is the sum of all the yearly anticipated operation and maintenance (O&M) costs. M is the sum of non-annually recurring operating, maintenance and repair costs. E is the energy cost, i.e. the sum of the yearly gas and electricity expenditure. R is the replacement cost, i.e. the sum of all replacement anticipated over the life of the intervention. The PV subscript indicates the present value of each factor.
The WLC of each intervention set was calculated over a 25-year period and expressed in NPV terms. The base date chosen was 2005 and hence the values of variables such as cost of energy consumed, capital and operational costs
© Woodhead Publishing Limited, 2010
552
Materials for energy efficiency and thermal comfort in buildings
of the technologies relate to this base date. The major assumptions made in producing the costing assessment are given in Table 22.6. The discounted cost of the investment was computed using a range of different annual increases in gas utility tariff. Only when these annual increases became substantial, i.e. 12% each year of the period studied, did the discounted cost of the investment in external wall insulation reach zero within the 25-year period (Fig. 22.11). It would therefore appear that only a limited economic case can be made for investing in an external wall system of the type described here. A number of extremely important caveats need to be considered when arriving at this conclusion, however, some of which are discussed in more detail.
Table 22.6 Major assumptions used in the WLC calculation Property
Condition
Capital cost of system Total cost of system Periodic maintenance assumption Periodic maintenance cost Initial utility tariff (gas) Energy saving (80% of external wall)
£93/m2 [Peacock et al., 2009] £12 850 2% of wall area every 8 years £250 £0.0208 7750 kWh
0% pa
2% pa
Annual increase in utility gas tariff 4% pa 6% pa 8% pa
10% pa
12% pa
Discounted cost of investment (£)
14 12 10 8 6 4 2 0 0
5
10
Time (years)
15
20
22.11 Effect of annual gas tariff increase on the discounted cost of investing in external wall insulation for the solid wall detached dwelling.
© Woodhead Publishing Limited, 2010
25
Materials for energy efficiency and thermal comfort
553
Caveat 1 The only benefit that is applied to the installation of the external wall system is the resultant fall in utility bills for the dwelling. The presence of secondary benefits that are outside the narrow remit of energy consumption have been the subject of numerous studies dating back more than 15 years. However, their identification has not led to their inclusion in conventional techno-economic assessment of energy efficient technologies of the sort being carried out here. Space does not permit an adequate assessment and subsequent quantification of the specific secondary benefits that may be accrued by the deployment of external insulation systems. It does, however, represent a significant research gap. An excellent review of the literature concerning the quantification of the co-benefits of improved efficiency in buildings is provided by Ürge-Vorsatz et al. (2009). Caveat 2 The capital cost figures were sourced from a current market entrant in 2005. The current total market size for retrofit external insulation wall systems in the UK is approximately 17 500. As we have seen, if this technology is to contribute to the UK CO2 emission reduction targets, the number of installations per annum will probably have to rise to somewhere between 0.5 and 1.0 million per annum. This market growth will fundamentally alter the supply chain dynamics and knowledge/skill base of both the system acquisition and the installation of the product on site. In order that the discounted cost of the system is zero or less over the 25-year period (assuming that the rise in utility gas tariff is 3% p.a.), the capital cost would have to fall from £12 800 (£93/m2) to £5 400 (£39/m2). Assuming that the required market growth indicated above is realised and that the number of installations grew to approximately 600 000 per annum, this would represent a learning rate (reduction in capital cost per doubling of market volume) of 19.5%. This is not a fanciful figure given the range of rates reported in the literature for a range of technologies, some of which are not subject to the strict rigours imposed by factory production (Table 22.7) (Tam, 2007). Clearly, this learning rate would benefit building owners or householders who were late market entrants. The number of systems that would have to be installed to achieve this fall in capital cost would be approximately 270 000. If these systems were to receive a subsidy (a learning investment) to reduce the capital cost to the level enjoyed by the late entrants, the total cost of subsidy would be approximately £561 million. However, as important as identifying the possible size of subsidy required is the intention of using it specifically to promote technology diffusion in the marketplace.
© Woodhead Publishing Limited, 2010
554
Materials for energy efficiency and thermal comfort in buildings
Table 22.7 Learning rates for a range of different technologies Technology Country/Region Period
Learning rate (%)
Ford Model T Refrigerators Clothes washers Dishwasher Room air conditioning Heat pumps Heat pumps Façades with insulation Double glazed coating windows CFL
13 12 13 16 15 30 24 17–21 12–17 10
USA USA USA USA USA Germany Switzerland Switzerland Switzerland Global
1909–23 1980–98 1980–98 1980–98 1980–98 1980–2002 1980–2004 1975–2001 1985–2001 1990–2004
The mechanism of distribution, marketing, start-up and exit strategy of any subsidy scheme is as important as the scale of the subsidy itself (Heimdal and Bjørnstad, 2009). Caveat 3 Narrow techno-economic assessments of the sort carried out here assume that householders are (a) rational economic actors who obey price signals and act accordingly and (b) have the ability to view investments over a long time frame (in the case cited here – 25 years). The perception of cost and value is not, however, as precise an exercise as perhaps the whole life cycle costing exercise suggests. The WLC approach neglects important cultural signals that may exist to link consumerism and ownership with, for instance, status, aspirations and societal responsibility. The extent to which the consumer becomes aspirationally attuned towards ownership of an energy efficient dwelling may play as important a role in the evolution of a mass market for energy efficiency products as their capital cost.
22.9.2 Householder willingness to pay To explore the relationship between householder perceptions and cost of intervention strategies, the TARBASE research group conducted a ‘willingness to pay’ survey between 31 March and 4 April 2008. It was representative spatially and socio-demographically amongst 1004 UK homeowners over the age of 18. The aim of the survey was to probe householders’ response to the idea of spending relatively large sums of money on energy saving technologies. The timing of the survey was such that it was after the collapse of the Northern Rock Bank in the UK but before the fall of Lehman Brothers. An element of the effect of the credit crunch was already prevalent at the time of the survey. This is an important factor in considering its relevance
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
555
to today’s market conditions. An overview of some key findings from the survey is provided here. A more comprehensive analysis has been conducted by Berry et al. (2009). The respondents were asked to consider purchasing a set of measures that will (a) save 60% of their current fuel bills but will have a one-off fee of £10 000, (b) save 40% of their current fuel bills but will have a one-off fee of £5000, or (c) save 20% of their current fuel bills but will have a one-off fee of £1000. A brief description of the type of technologies was provided. These included insulation measures, although a precise description of external wall insulation measures was not provided. The approximate fiscal saving associated with a 60%, 40% and 20% reduction was not provided although the respondents were informed that the average UK household utility bill was approximately £1200. This allowed the respondents to calculate a saving and simple payback themselves if they so desired. Not unsurprisingly, the proportion of respondents who were very interested in purchasing the measures increased as the cost fell (Fig. 22.12). Interestingly, 5% of respondents (53 in total) were very interested in spending £10 000 on the heat saving fixes (Fig. 22.12). Potentially, this is an extremely important group. If we consider Rogers’ model of new product diffusion that was discussed earlier, this group could be said to represent the innovator sector – those people who would be willing to adopt a new technology or in this case basket of technologies. Two key factors that distinguish this potential innovator class are selected for analysis here. The first is the gross household income. The innovator class was found to be wealthier than the group as a whole. The average household income in the survey was approximately £30 000 p.a. The average household income for those respondents who were very interested in spending £10 000 on energy efficiency technologies was found to be approximately £40 000 p.a. with an analysis of variance revealing a statistically significant difference (P-value = 0.0) found between the respondents as disaggregated by their willingness to pay (Fig. 22.13). The size of the innovator sector also increased as the income level increased (Fig. 22.14). For instance, it was found to be 3.6% and 9.5% of respondents for income levels below and above £30k respectively and 14.5% for respondents with salaries in excess of £70k p.a. Another key discriminating factor associated with the innovator sector was that they were more likely to expect the value of their home to be positively affected by the adoption of energy saving measures (Fig. 22.15). Indeed, approximately 80% of respondents in the innovator sector thought that the value of their home would increase by at least as much as the cost of the interventions themselves. This suggests that the motivation for adopting these measures remains predominantly fiscal. The innovator sector perceives that the interventions will at worst be cost neutral when asset value is considered.
© Woodhead Publishing Limited, 2010
556 45
% respondents
40
Materials for energy efficiency and thermal comfort in buildings Spending £10k
Spending £5k
35 30 25 20 15 10 5
(a) 45
Don’t know
(b) Spending £1k
40 % respondents
Not at all interested
Not very interested
Fairly interested
Very interested
Don’t know
Not at all interested
Not very interested
Fairly interested
Very interested
0
35 30 25 20 15 10
Don’t know
Not at all interested
Not very interested
Fairly interested
0
Very interested
5
(c)
22.12 Proportion of respondents who would be interested in purchasing energy saving technological interventions.
22.9.3 Other factors Respondents who had children were more likely to be in the innovator sector – 7% compared to 4% of those respondents who did not have children in the house. The respondent’s educational attainment was not found to be a clear indicator of a positive attitude to adopting energy efficiency measures, whereas it was found to be an indicator of a negative attitude to their adoption. For instance, of those respondents who had some form of tertiary education qualification, 5.7% of respondents were found to be in the innovator sector compared to 5.1% of those who had no tertiary education qualification. However, 33% of respondents with a tertiary education qualification expressed
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort F Test 8.8 P Value 0.0 Interest level Very Fairly Not very Not at all Interest level + Very Fairly Not very Not at all
Mean 39 990 33 058 30 380 26 019 +
* + 24 000
*
StDev 28 902 22 069 21 075 19 101 + *
*
557
+
+ + + 30 000 36 000 42 000 Household income (£ pa)
22.13 Household income level of respondents disaggregated by level of interest. 16
% Respondents
14 12 10 8 6 4 2 50–70k
Greater 70k
40–50k
30–40k
25–30k
20–25k
15–20k
10–15k
Under 5k 5–10k
0
22.14 Innovator class disaggregated by income level.
no interest in spending £10k on energy efficiency measures compared to 41% of those with no qualification. A series of behaviours were described and respondents were asked whether they had carried them out to reduce energy consumption in their home. These included replacing incandescent light bulbs with CFLs, monitoring household energy consumption and not leaving appliances on standby. Whilst the innovator sector suggested that they were more likely to display these kinds of pro-environmental behaviour, the differences were marginal and were not found to be significant when compared to other sectors. The respondents were asked if they would be interested in having an energy-related makeover for their home where a company came in and carried out all of the work in a short period of time. They responded on a scale of 1 to 10 where 1 is not at all interested and 10 is extremely interested. The innovator sector scored 8.2 on this measure indicating strong support for
© Woodhead Publishing Limited, 2010
558
Materials for energy efficiency and thermal comfort in buildings
70
I expect the value of my home to be increased by more than the amount that I spend on energy efficiency improvements
Respondents (%)
60 50
I expect the value of my home to be increased by exactly the same amount that I spend on energy efficiency improvements
40 30
I expect the value of my home to be increased by less than the amount that I spend on energy efficiency improvements
20 10 0
Very Fairly Not very Not at all interested interested interested interested
I think the value of my home will stay the same (neither increase nor decrease) as a result of investing in energy efficiency improvements
22.15 Perception of respondent to the effect of energy efficiency measures on the asset value of their property disaggregated by respondent’s response to purchasing a set of measures that will save 60% of their current fuel bills but will have a one-off fee of £10 000.
this type of one-off deployment. A potentially major barrier to the adoption of deep cut intervention sets is the transactional exhaustion associated with the householder having to deal with more than five companies/technologies to achieve the overall savings.
22.10 Summary The UK domestic stock is responsible for approximately 27% of total UK CO2 emissions. By disaggregating this stock it is possible to deduce that almost half of the total emissions from the sector can be attributed to solid wall dwellings. In turn, the proportion of the total emissions of a single dwelling that are as a consequence of heat loss from a solid, uninsulated wall are between 30 and 40%. There is therefore a compelling case for the widespread adoption of fabric improvement measures. External wall insulation systems should be favoured over internal insulation systems as the latter may exacerbate the potential emergence of a domestic cooling season in the south of the UK as a consequence of isolating the thermal mass of the dwelling from the internal space. A substantial number of solid wall dwellings would appear to exist that are outside conservation areas in the UK and therefore not necessarily subject to planning restrictions associated with a change in appearance. The existing market for external wall insulation systems is extremely small but technologies exist based on conventional insulation materials that have been in the marketplace for as long as 20 years.
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
559
The carbon payback for external wall insulation systems is likely to be less than 2 years. However, based on a narrow techno-economic calculation, the economic payback time is unlikely to be anything much less than 25 years even with substantial reductions in capital cost. There is an urgent need to broaden the scope of this form of analysis. To a degree the applicability of technological innovation is a function of the narrative and story that we generate. Successive studies have shown on the one hand that the achievement of deep cut emission targets cannot be realised without domestic sector intervention, whilst at precisely the same time deep cut intervention sets are not economically rational for householders. An alternative narrative has to be developed to address this evident dichotomy. One possible route forward may be in addressing the problem as one of classic market development and technology diffusion. Subsidies are therefore targeted at key technologies to establish a marketplace with the delivery mechanism, timing and exit strategy of the subsidy being as important as the scale of subsidy. This subsidy should be designed so as to stimulate a nascent innovator and early adopter class so that late market entrants can benefit from the capital reductions that are likely to flow from the development of a mass market. This conclusion is applicable to all domestic sector technological innovations aimed at producing deep cuts in emissions.
22.11 Sources of further information and advice A number of UK-based research groups are working in the areas covered in this chapter. The RESOLVE project led by Professor Tim Jackson at Surrey University is seeking to provide robust, evidence-based advice to policy-makers in the UK and elsewhere who are seeking to understand and to influence the behaviours and practices of ‘energy consumers’. The Carbon Vision Buildings programme was a UK-based research project that considered both behavioural and technical aspects of reducing CO2 emissions in the existing building stock. Project websites and information can be found at http://www.epsrc.ac.uk/ResearchFunding/Programmes/Energy/ Funding/CarbonVision/BuildingsProjects.htm
22.12 References Anderson B (2006), Conventions for U-value Calculations, BRE Scotland. Baker P (2008), In situ u-value measurements in traditional buildings – preliminary results, Historic Scotland, Glasgow Caledonian University. Balaras CA (ed.) (2003), EPA-ED, Benchmarking for existing European dwellings, April 2003, Task 1. Belcher SE, Hacker JN and Powell DS (2005), Constructing design weather data for future climates, Building Services Engineering Research and Technology, 26, 49–61. BERR (2009), Digest of UK Energy Statistics, BERR, May 2009.
© Woodhead Publishing Limited, 2010
560
Materials for energy efficiency and thermal comfort in buildings
Berry A, Branston H and Jackson T (2009), To pay now, or to pay later – that is the question: an assessment of homeowners’ willingness to pay for energy saving measures, RESOLVE Working Paper, University of Surrey. Bottrill C (2005), Homes in Historic Conservation Areas in Great Britain: Calculating the Proportion of Residential Dwellings in Conservation Areas, 40% House Background Document K, Environmental Change Institute, 2005. BRE (2008), Energy analysis focus report – A study of hard to treat homes using the English house condition survey, Part 1: dwelling and household characteristics of hard to treat homes, BRE Housing. CIPFA (2001), Chartered Institute of Public Finance and Accountancy, Planning and Development Statistics, London. DCLG (1994), Planning Policy Guidance 15: Planning and the Historic Environment, 1994. DCLG (2008), Housing Statistics, http://www.communities.gov.uk/publications/corporate/ statistics/housingstatistics2008. DEFRA (2008), Climate Change Act 2008 – key provisions. Available from: http:// www.defra.gov.uk/environment/climatechange/uk/legislation/provisions.htm (accessed May 2009). DEFRA (2009), e-Digest of Statistics, http://www.defra.gov.uk/environment/statistics/ globatmos/gakf07.htm (accessed May 2009). EST (2008), UK Domestic Solid Wall Insulation, Sector Profile – Executive Summary, 2008, Energy Saving Trust, UK. Geller H and Attali S (2005), The experience with energy efficiency policies and programmes in IEA countries, International Energy Agency. Hammond G and Jones C (2006), Inventory of carbon and energy (ICE), Version 1.5, Beta, University of Bath, 2006. He J, Young AN, Pathan A and Oreszczyn T (2005), Air Conditioning Energy Use in Houses in Southern England, Dynamic Analysis, Simulation and Testing Applied to the Energy and Environmental Performance of Buildings Conference, Athens. Heimdal SI and Bjørnstad E (2009), A policy model for diffusion of electricity saving technologies, European Council for an Energy Efficient Economy, Summer Study, Cote d’Azur. Hinnels M (2006), Building Market Transformation, Environmental Change Institute, Oxford, http://www.eci.ox.ac.uk/research/energy/downloads/bmt-july06.pdf HM Treasury (2003), The Green book: appraisal and evaluation in central government. Available from: http://www.hm-treasury.gov.uk/media/3/F/green_book_260907.pdf (accessed May 2009). INCA (2009), Insulated Render and Cladding Association, UK, http://www.inca-ltd.org. uk (accessed May 2009). Levine M, Ürge-Vorsatz D, Blok K, Geng L, Harvey D, Lang S, Levermore, G, Mehlwana AM, Mirasgedis S, Novikova A, Rilling J and Yoshino H (2007), Residential and commercial buildings. In: Metz B, Davidson OR, Bosch PR, Dave R and Meyer LA (eds), Climate Change 2007: Mitigation. Contribution of Working Group III to the Fourth Assessment Report of the Intergovernmental Panel on Climate Change. Cambridge: Cambridge University Press. Lewis M (2009), Australian building: a cultural investigation, section 6.3: the cavity wall, www.mileslewis.net (accessed May 2009). Lowe R (2006), private communication. Masini G, Bowles G, Peacock AD and Ahadzi M (2010), Whole life costing of domestic
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
561
energy demand reduction technologies and its social implications, Construction Management and Economics, Article in press. OFGEM (2008), Carbon Emissions Reduction Target (CERT) 2008-2011 Technical Guidance Manual, OFGEM, UK. OPSI (1990), Town and Country Planning Act, 1990, Section 69. Peacock AD, Banfill PF, Newborough M, Kane D, Turan S, Jenkins D, Ahadzi M, Bowles G, Eames PC, Singh H, Jackson T and Berry A (2007), Reducing CO2 emissions through refurbishment of UK housing. In: European Council for an Energy Efficient Economy (eceee) 2007 Summer Study, Côte d’Azur, France, 4–9 June 2007. Peacock AD, Jackson T, Berry A, Ahadzi M and Massini A (2009), Market Development Potential of Residential Refurbishment Packages, European Council for an Energy Efficient Economy (eceee) 2009 Summer Study, Côte d’ Azur, France, 1–6 June 2009. Pett J (2001), Affordable warmth for hard to treat homes: Finding a way forward?, Briefing Paper, ACE, 2001. Rogers EM (2003), Diffusion of Innovations. New York: Free Press. Sailor DJ and Pavlova AA (2003), Air conditioning market saturation and long-term response of residential cooling energy demand to climate change, Energy, 28, 941–951. Shorrock LD and Utley JI (2003), Domestic energy fact file 2003. BRE. SPAB (2009), The society for the protection of ancient buildings (SPAB), the manifesto, http://www.spab.org.uk/html/what-is-spab/the-manifesto/ (accessed May 2009). Tam C (2007), Deploying Demand Side Technologies, ETP 2008, IEA, Paris. TARBASE (2009), TARBASE Project website, www.tarbase.com UKCIP (2009), UK Climate Impacts Programme, http://www.ukcip.org.uk/ UNECE (2006), United Nations Economic Commission for Europe, Bulletin of Housing Statistics for Europe and North America, 2006. Ürge-Vorsatz D, Novikova A and Sharmina M (2009), Counting good: quantifying the co-benefits of improved efficiency in buildings, European Council for an Energy Efficient Economy, Summer Study, Côte d’Azur, 2009. Wilhite H (2007), Will efficient technologies save the world? A call for new thinking on the ways that end-use technologies affect energy using practices, European Council for an Energy Efficient Economy, Summer Study, Côte d’Azur. Wright AJ, Young AN and Natarajan S (2005), Dwelling temperatures and comfort during the August 2003 heat wave, Building Service Engineering, 26, 285.
© Woodhead Publishing Limited, 2010
23
Materials for energy efficiency and thermal comfort in commercial buildings
D. H. C. Chow, University of Nottingham Ningbo, China
Abstract: Commercial buildings contribute to a significant portion of the total energy usage and subsequent carbon emissions. Due to their nature, they can use much more energy than they are designed to use, and could be labelled as ‘energy wasters’. What this also means is that there is a large potential for improving their performance. In this chapter, the nature of office buildings, retail spaces and warehouses will be examined and issues affecting their energy use discussed in detail. Ways in which to reduce their energy consumption will also be considered. These include changes in building design and materials used in construction, changes in user behaviour, the increase of control and monitoring and the advancement in building technology and mandatory regulation. Key words: commercial buildings, energy efficiency, passive systems, climate change, control, monitoring.
23.1
Introduction
In Part L of the Building Regulations for England and Wales, Conservation of Fuel and Power, commercial buildings are classed as non-domestic buildings together with public buildings. The reason is that in terms of total energy usage and usage pattern, non-domestic buildings are very different from domestic buildings. Non-domestic buildings account for about one-sixth of the total UK CO2 emissions and approximately one-third of building-related ones (Bordass 2001). The basic nature of buildings in the non-domestic sector is very different from that in the domestic sector. Often these buildings use much more energy than they should and could. Before thinking about the carbon content of the delivered energy, building designers need to look at the current trends in usage and how these can be lowered. Many non-domestic buildings use far more energy than they need to, and can be termed ‘major energy-wasters’. Even many new buildings are using much more energy than their designers anticipated. There are many reasons for this, including designers underestimating the energy requirement, or the occupants not understanding how the building should operate. In this chapter, the types of commercial buildings we will be looking at in detail are offices, retail spaces and warehouses. The energy requirement 562 © Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
563
specific for these types of building, the possible differences between the design usage and actual usage, the ways which this gap could be reduced, and also the trends in energy usage due to climate change in the UK will be discussed.
23.2
Energy efficiency and thermal comfort in offices
The office building is an important building type to consider, as many people spend most of their day inside one. As a result, its energy usage and CO2 emissions are comparable to that for dwellings. It has its unique characteristic technologies such as raised floor and suspended ceiling, which affects its performance and also consequential environmental impacts.
23.2.1 Main differences from dwellings Compared to dwellings, office buildings differ in many ways. The way which offices use energy may be less diverse than for dwellings, so the range of CO2 emissions may be smaller. Offices also tend to contain more high-embodied energy equipment (such as specialist luminaires) than dwellings. Based on data from the Movement for Innovation (M4i) (2001), Fig. 23.1 shows that in terms of emission per area, the average office emits less operational CO2 than the average dwelling. However, the range of emission is much greater. For embodied energy, this trend is reversed, whereby on average, the office emits much CO2, but the range is smaller than that for dwellings.
23.2.2 Situation in offices There are a number of factors that determine the energy consumption load for office buildings. Generally, these factors induce extra thermal gains in offices, usually from occupants, equipment and solar gains, so the requirement of cooling in summer is usually much higher than in dwellings. Dress code The average office worker wears business suit or dress, which has a clo value of around 1.0 in the CIBSE Guide A (2006). In some offices, this dress code is strict, and restricts the possibility of removing items when it is too hot and putting on extra items when it is too cold. As a result of this lack of clothing adaptability, the band of occupant comfort is narrow, and extra mechanical cooling and heating may be required.
© Woodhead Publishing Limited, 2010
564
Materials for energy efficiency and thermal comfort in buildings
Operational CO2, kg(CO2) m2 pa
300 250 200 150 100 50 0
Dwellings
Offices
Dwellings
Offices
Embodied CO2, kg (CO2) m2
1200 1000 800 600 400 200 0
23.1 Range and 50th percentile for operational and embodied CO2 for dwellings and offices.
Office equipment The majority of equipment used in offices emit vast amounts of heat. These include computers, printers, photocopiers, etc. This adds to the cooling load of offices, especially in summer. Lighting should also be included here, as it is a major source of internal gain in offices, as well as specialised equipment. The amount of heat generated by office equipment and machines can be found from manufacturers’ data; otherwise general values are available from CIBSE Guide A. Although the efficiency of most office equipment is improving constantly, resulting in a reduction in the amount of waste heat generated, there is also a growing trend in the amount of equipment in offices, which puts the internal heat gains at approximately the same level.
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
565
External design of office buildings Modern offices tend to prefer glass façades, which can result in excess solar heat gain. Developments in glass technology have resulted in glass that lets in light, but keeps out most of the solar heat gains, but excessive glazing on the façade still lets in a large amount of solar gain into the building. The use of photovoltaic cells on glazed façades will serve to reduce the amount of solar gains as well as generating electricity for the building, without changing much of the architecture and appearance of the building. Internal design of offices Office buildings can be cellular or open-planned. Open-planned offices may create a better working environment, but if the design is deep-planned, it may not be possible to use natural ventilation to serve the central locations. It is also difficult for natural daylight to penetrate into the core areas at sufficient levels. False ceilings and carpeted floors will also reduce a building’s ability to absorb heat, limiting the building’s ability to use thermal mass and thus passive cooling strategies such as night-cooling, where the heat stored inside the building fabric is released to the cooler air at night time, to restore its thermal storage capacity. Productivity in office buildings Surveys of office workers reveal that the physical environment of the office is a main factor that affects productivity. It was found that thermal problems, poor air quality (stuffiness), sick building syndrome factors and crowded work places are amongst the most frequent complaints (Clements-Croome 2003), and by improving office environmental conditions, improvements of 4–10% in productivity is suggested. All these factors contribute to a far greater need for cooling in office type buildings than in domestic buildings. In recent years, office buildings in the UK are acquiring more and more air conditioning or other forms of mechanical cooling. With the effects of climate change, this is becoming even more common. A recent study by Chow (2005) shows that in the UK, in order to preserve occupant comfort and maintain productivity, all office buildings in the south of England will require mechanical cooling by the 2020s, those in the north of England by the 2050s, and those in Scotland by the 2080s. Sick building syndrome Sick building syndrome is connected to the use of full air conditioning systems in offices. Symptoms in sufferers mostly disappear when natural © Woodhead Publishing Limited, 2010
566
Materials for energy efficiency and thermal comfort in buildings
ventilation is introduced. This is a problem that needs to be tackled as the need for mechanical cooling increases with climate change. Where possible, natural ventilation should be encouraged in office buildings, and when this is not capable of achieving the cooling demand, mechanical cooling or air conditioning can be used. This is known as mixed-mode ventilation (see Chapter 3), and is an effective strategy in reducing energy usage and cases of sick building syndrome as well as maintaining occupant comfort and productivity.
23.2.3 Good practice/typical practice: ECON19 or ECG019 From the early 1990s, the Energy Consumption Guide 19 (Carbon Trust 2000) summarised a comprehensive energy survey for office buildings. This publication is regularly updated and is otherwise known as ECON 19 or ECG019. Based on results from 200 offices across the UK, four categories of office types were distinguished for ECG019. These are: 1. 2. 3. 4.
Naturally ventilated, cellular Naturally ventilated, open-plan Air-conditioned, standard Air-conditioned, prestige
CO2 emissions in kg (CO2).m–2 pa
It was found that the biggest difference in terms of energy usage between the categories was the requirement for air conditioning and electrical equipment. The increases needed for heating, hot water and lighting were negligible in comparison (Fig. 23.2). As well as dividing office buildings into four categories, ECG019 gives benchmarks for ‘Typical’ energy consumption 60 50 40 30 20 10 0
Type 1
Type 2
Other electrical equipment
Type 3 Air-Con
Lighting
Type 4 Heating & hot water
23.2 Carbon dioxide emissions from ECG019’s office types (‘Typical’ offices).
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
567
and ‘Good practice’ energy consumption, depending on how energy is used in the building. These are defined as follows: ∑
∑
‘Typical’ energy consumption patterns, which are consistent with median values of data collected in the mid-1990s for the Department of the Environment, Transport and the Regions (DETR) from a broad range of occupied office buildings. ‘Good practice’ examples in which significantly lower energy consumption has been achieved using widely available and well-proven energy-efficient features and management practices. These examples fall within the lower quartile of the data collected.
Different office types have different energy usage and CO2 emission. It was also found that the difference between ‘Typical practice’ and ‘Good practice’ also has a large effect. A similar breakdown of CO2 emissions for ‘Good practice’ office types is shown in Fig. 23.3. ECG019 suggested that offices built from the 1990s should be ‘Good practice’. Although this is being implemented, the existing stock of older office buildings is still a major cause of concern. From the 2002 edition of the Building Regulations Part L2, Carbon Performance Rating (CPR) is included. This is specifically aimed at Type 3 and 4 offices, as they use air conditioning and mechanical ventilation.
23.2.4 Journey to work
CO2 emissions in kg (CO2).m–2 pa
The actual CO2 emissions directly accounted for by the construction and operational energy use of buildings is around 50% of the total emissions in the UK, whereas transport between buildings accounts for around 22% 60 50 40 30 20 10 0
Type 1
Type 2
Other electrical equipment
Type 3 Air-Con
Lighting
Type 4 Heating & hot water
23.3 Carbon dioxide emissions from ECG019’s office types (‘Good Practice’ offices).
© Woodhead Publishing Limited, 2010
568
Materials for energy efficiency and thermal comfort in buildings
(McEnvoy and Dye 2008, p. 150). This is a substantial amount, and could be attributed to office buildings as most office workers commute to work on average five days a week, more frequent than journeys to other buildings from their home. As a result, BREEAM (Building Research Establishment Environmental Assessment Method) includes transportation as part of its assessment criteria, and the provision of cycle racks to encourage workers commuting by bicycle would earn extra credits on the BREEAM Rating (Baldwin et al. 1998).
23.2.5 Lighting and artificial lighting Glazing in offices needs to be carefully designed to make optimum use of daylight. A balance between heat loss, daylight and solar gain needs to be considered. Ideally, the internal finishes should be light in colour. Artificial lighting contributes to a significant proportion of the operational energy used in office buildings. Its use is unavoidable as sufficient daylight is not always available (this is particularly true for deep open plan offices), and offices are also often used well into the night when daylight is no longer available. Since artificial lighting is indispensable in office buildings, it should be designed to provide ambient conditions similar to that provided by natural lighting. Energy efficient lighting is therefore necessary to minimise the amount of energy used. This means not only energy efficient lamps, but also for luminaires and the whole lighting strategy and system. Occupancy sensors for switching lights on and off, as well as external sensors for dimming lights according to the amount of daylight available are some of a large array of strategies that could be used. PSALI (Permanent Supplementary Artificial Lighting of Interiors) is another popular system of combined daylighting and artificial lighting where parts of the interior are lit for the whole time by artificial light, which is designed to balance and blend with the daylight (Fig. 23.4). The advance and development of low energy LED lighting has also reduced the lighting energy in many office buildings and it is envisaged that their use will become more commonplace in the near future. As well as providing energy efficient artificial lighting, office buildings can also reduce the required amount of artificial lighting by introducing more daylight into the building, especially in areas far away from the building perimeter. Sun-pipes, light-wells and light-shelves are examples of such methods.
23.2.6 Air conditioning and natural ventilation High internal gains and the general reluctance to use passive methods for summer cooling due to security concerns have led to an increase in the use
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort Psali light on
Total illumination Window Illumination due to PSALI fitting
Illumination due to daylight
Illuminance level
Night light off
569
23.4 Schematic of the theory behind the PSALI system.
of heating, ventilating and air conditioning (HVAC) systems in UK offices. There are also pollution and health reasons for office buildings situated close to heavy traffic not to employ simple natural ventilation. The use of HVAC is particularly difficult to avoid in prestigious conference rooms and also inner spaces in office buildings. However, there are situations where natural ventilation could be used, either totally or as part of a hybrid system. This may gain greater user acceptance if they are given more control and if it matches more closely to the varying outdoor climate (adaptive comfort). Problems of air leakage will also need to be addressed, in order to control the amount of air passing through the building. This is a particular problem with high-rise office buildings, as the velocity of wind increases with the distance above ground due to a reduction in resistance from other buildings and obstructions. Recently, atria and internal stairwells have been used as part of a natural ventilation strategy. These strategies allow fresh air to be brought into the building even when the windows are shut. For building designers, the aim is to have ‘Building tight and ventilating right’ (McEnvoy and Dye 2008, p. 158). The CIBSE Recommendation (CIBSE 2006) is that for natural ventilation alone to be feasible, the dry resultant temperature of the office should not exceed 25 °C for more than 5% of the occupied time (approximately 100 hours a year). The European Recommendation (Cohen et al. 1993) has a similar rule, with the dry resultant temperature not exceeding 28 °C for more than 1% of the occupied time (approximately 20 hours a year). If an office complies with either rule, then it is suggested that natural ventilation alone is sufficient to provide summer cooling. However, other considerations such as the outside air quality, particularly if there is heavy traffic, would need to be taken on board. At present in the UK, there are already days in the summer when the outdoor temperatures are greater than the indoor comfort temperatures. In
© Woodhead Publishing Limited, 2010
570
Materials for energy efficiency and thermal comfort in buildings
these cases, using external air for cooling will not work, so windows are best kept shut, and mechanical fans are used to generate a draught for cooling. Climate change models such as HadRM3 (Chow et al. 2002) suggest that the occurrence of this situation will increase in the next 100 years in the UK, so the use of mechanical ventilation appears unavoidable. It then becomes a case of maximising the potential of natural ventilation where possible. Hybrid ventilation (or mixed mode ventilation) will become the standard means of ventilating in sustainable office buildings. Control systems and intelligent window systems could all be part of the overall strategy. Passive solar heating in winter Office buildings designed to make use of passive solar heating in winter will usually have glazing facing southwards. These will have reduced solar gains in the summer as the solar altitude would be higher, and the overhangs (some also double up as access for window cleaning) should be sufficient. However, special attention should be paid to glazing facing east or west. In summer, the altitude of the sun is still low enough for strong solar radiation to penetrate into the buildings. The problem is particularly true for west-facing or south-west-facing elevations, as the daily maximum temperature in summer usually occurs at around 14:00 to 15:00 (Chow and Levermore 2007). These elevations will be faced with a ‘double effect’ of high external temperature and also direct solar radiation entering the space. In terms of thermal storage, on hot summer afternoons, the building fabric could reach its thermal capacity making further passive cooling unavailable. So the situation for west-facing façades is particularly problematic in the summer. Adjustable shading could be used, but moving parts mean that maintenance could be an issue. Although the main source of overheating is by solar radiation entering through windows, shading the external wall can also be beneficial as it keeps the building fabric cool. There is now glass that allows light to pass through, but is also relatively successful at blocking out thermal radiation (Ohsaki and Kokubu 1999).
23.3
Energy efficiency and thermal comfort in retail spaces
Just like office buildings, retail spaces have specific needs. A successful retail space will be able to attract customers into the shops from the streets outside. Typical methods include using elaborate lighting and providing indoor conditions which are more comfortable and appealing than the outside. In hot and humid locations such as Hong Kong, indoor shopping malls, as well as restaurants and cinemas, often used to turn on their air conditioning units to provide temperatures of under 15 °C (Chow and Fung 1995), as
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
571
the low temperatures will draw passers-by into the retail space who want to escape the heat and humidity outside. However, once the brief satisfaction is achieved, most people actually find these spaces too cold. Despite this, many retail spaces continued this practice as it promoted a healthy turnover of potential customers into the shops. In terms of public health and excessive use of energy and subsequent carbon emissions, this is not good practice, and in 2005, the government of Hong Kong recommended an air conditioning set-point of 26 °C, with the inside temperature kept between 23 and 25 °C (Yang and Zhang 2008), to limit the minimum internal temperatures in public and retail spaces. As well as a seemingly more comfortable indoor environment, retail spaces also use extravagant lighting to attract potential customers. Sometimes these dazzling lights are left on at night-time even when the retail spaces are closed for business. Again, this leads to energy wasted unnecessarily. In many places, this also applies to office buildings. To combat this, ‘lighting curfews’ are in place for cities such as Shanghai (Da Yong 2004), where lights need to be switched off or dimmed in retail or public buildings after a certain time. In Shanghai, the time for switching off lights is 23:30. However, in most countries, this is difficult for security and insurance policy reasons.
23.3.1 Shopping centres and supermarkets In the UK, retail spaces have the same environmental issues to consider. In the last 20 years, more and more large-scale shopping centres are being built in out-of-town suburban areas. These are typically low-rise developments using large areas of land, and surrounded by vast amounts of car parking. To a certain extent, the same is also true for supermarkets. Under guidance issued by the Planning Policy Statement 6: Planning for Town Centres (PPS6) (DCLG 2005), however, retail spaces should be accessible by different modes of transport, but with public transport the preferred option rather than relying exclusively on the use of cars. With this in mind, outof-city centre, peripheral sites are not ideal, whereas city centre sites would be more favourable environmentally when the transportation of shoppers is taken into account.
23.3.2 Lighting and artificial lighting Despite the fact that natural lighting has better colour rendering than artificial lighting, daylight is rarely exploited in retail buildings. The main reason is that any wall spaces available are usually taken up and used for display purposes. Another reason is that the UV in daylight may damage certain goods for sale. There is also an increasing trend for retail buildings to be used after sunset, so the use of artificial lighting is almost unavoidable. Well-designed
© Woodhead Publishing Limited, 2010
572
Materials for energy efficiency and thermal comfort in buildings
display lighting will improve the appearance of goods in the shops, and is especially true for food products in supermarkets, where colour rendering is highly important. A good lighting scheme in retail spaces encourages people to enter, it allows shop windows to be used for display purposes, and is highly important for the success of the retail space. Similar to the situation with office buildings, the advance and development of LED lighting has also transformed how artificial lighting is used in retail spaces. LED lighting can mimic natural daylight very closely, and is extremely energy efficient, so more and more retailers are using LED lighting to enhance the products they are trying to sell. These are often left switched on to attract potential customers even when the shops are closed for business. As LED lighting is much more energy efficient than traditional artificial lighting, and the quality of light produced is also far superior, it is envisaged that they will be used more and more in retail spaces.
23.3.3 Environmental design As discussed earlier, lighting is usually the largest proportion of energy usage in retail spaces, as retailers try to attract consumers. In larger shopping centres, electricity used for air conditioning and possibly for lifts is also dominant. The energy used for heating usually contributes a smaller proportion as most retail spaces are well-insulated, and during winter, most shoppers retain their outdoor winter clothing in shops. Due to the basic forms of enclosure, some supermarkets have slightly different energy usage characteristics from other retail spaces. A large proportion of energy use goes to lighting, and because most tend to have high ceilings and so a large volume to heat, space heating and domestic hot water also accounts for a fair proportion of the energy usage. Many supermarkets also include in-store bakery, delicatessen and restaurants. Figure 23.5 shows that in this case, food refrigeration is responsible for approximately half the total energy cost, air conditioning and lighting a quarter of the cost, with the bakery, space heating, domestic water and other electrical uses accounting for another quarter (DETR 1998). ele Oth Sp c u er a he c se ati e s ng
Bakery Lighting
Airconditio ning
Food refrigeration
23.5 Energy cost breakdown in a typical supermarket.
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
573
23.3.4 Freezer cabinets in supermarkets One of the distinctive features of supermarkets compared to other types of retail buildings is that they have a large number of refrigeration equipment for their products, and this alone contributes to a large proportion of the overall energy usage, with most of the energy consumed by the compressors. Depending on the layout of the store, it is possible to make use of the by-product heat from the refrigeration compressors to heat up parts of the supermarket. There are also simple yet effective ways to reduce energy use in freezer cabinets in supermarkets, such as having a regular maintenance schedule and ensuring that they are effectively defrosted. It is also important to check that doors in refrigerated store rooms are not left wide open, especially during restocking. The above may seem simple and obvious, but are not carried out in many supermarkets. There are self-closing doors with safety overrides that some supermarkets use. However, these are not yet extensively used, and there are known to have been cases where workers use heavy boxes to keep the doors open, as they think it is easier and quicker for them to restock. This is another example showing the way in which occupants use the building has far more impact than how the building is designed to be used.
23.3.5 Natural ventilation and air conditioning in supermarkets Supermarkets are mostly deep plan buildings. This, together with its particular usage, means the use of air conditioning may be unavoidable. Most modern supermarkets also include circulation spaces around the building, as well as public spaces such as cafés. These are usually located at the perimeter of supermarket buildings, and the use of natural ventilation may be feasible. Measures such as having roof-lights facing away from the sun and minimising the area of roof-lights will reduce the amount of solar gain entering the store, thus reducing the amount of mechanical cooling required. Solar shading on south-facing glazing using overhangs and louvres is also beneficial. In supermarkets with high volumes, the need for air conditioning is reduced, as the heat will rise and stratify above head height.
23.3.6 Typical construction Compared to office buildings, retail construction has a much wider variety of typologies, with inner city department store, suburban DIY depot, multi-storey shopping mall and suburban supermarket being probably the most common (McEnvoy and Dye 2008, p. 242). Insulation is particularly important in the UK to ensure energy efficiency. Newly built retail buildings complying
© Woodhead Publishing Limited, 2010
574
Materials for energy efficiency and thermal comfort in buildings
with the latest building regulations are environmentally efficient. For older existing retail buildings, improvements can be made to the building’s envelope when it is being refurbished. Shopping centres are very frequently refurbished, usually around every 8–10 years and as frequently as 6–7 years for popular locations. So, over the years, this input of materials and energy in refurbishment will be substantial over the life of the building. Improvements in older buildings when they are refurbished include upgrading wall and roof insulation, replacing or upgrading windows to double/multiple glazing, low-emissive coating, and introducing revolving doors to reduce heat losses and draught. For retail buildings, it is important to maintain a contemporary appearance, in order to retain market position for rents and mix of tenants (Prior 1999, Male et al. 2003). An example of this is the refurbishment of the Arndale Shopping Centre in Manchester, after it was damaged by bombings in 1996. The refurbishment programme took a total of five years to complete, at a cost of around £15 million. All work was undertaken whilst the centre remained in full public use, and the enhanced new malls have attracted major new retail operators.
23.4
Energy efficiency and thermal comfort in factories and warehouses
For the last 30 to 40 years, the trend in UK industry has been a reduction in heavy industry and a shift towards light engineering and services, which have significantly different requirements, so buildings for factories and warehouses are very different from those built before the 1970s (Jones 1990). In fact, closer control and construction standards means new factory and warehouse buildings may have similar performance to new office buildings, and it is existing older factories and warehouses, which have more air leakage and lower levels of thermal resistance, that pose a much bigger problem. Doors are a particular problem for factories and warehouses. If loading doors face away from the prevailing wind, the amount of heat loss through them will be minimised. They also need to be easily operable, so they would not be kept open when not required. Shelter belts of trees around the site could also reduce wind speed around the site, thus minimising heat loss. Reducing the slope of the roof would also reduce heat loss as this will create a smaller volume of space. It is estimated that much of the energy savings in UK factories and warehouses could be saved by changing a relatively small number of factors, notably the building’s insulation and air leakage, inadequacies in the heating system, loss in distributing heat around the building, lack of controls, lack of maintenance and inefficient lighting installations (Energy Efficiency Best Practice Programme 2004). It has been shown that most industrial buildings could be refurbished to a standard similar to new buildings (McEnvoy and
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
575
Dye 2008, p. 257). This suggests that the potential for energy savings and improved energy performances in the industrial sector is very high.
23.4.1 Environmental design in warehouses In the 1990s, a government-funded research programme classified factory buildings into four types (Energy Efficiency Best Practice Programme 2004): ∑ buildings for storage and distributions ∑ factories for light manufacturing ∑ factory/office buildings ∑ general manufacturing buildings. Warehouses are buildings mainly for storage and distribution, and can be seen as factory buildings with no production, so with far fewer problems, such as pollution and the energy intensity in the production process. They belong to the first of the four categories above. They typically have a clear height of around 7.5 m, and could be naturally ventilated and heated to around 16 °C. Natural ventilation is suitable for warehouses as they do not have excessive heat gains, and occupancy levels are usually low. The biggest problem for warehouse buildings in terms of energy efficiency is heat loss through air leakage. This applies to warehouses both new and old, and potentially this could double the amount of heating required. Air leakage is related to external wind speed, so for buildings in exposed sites, the problem is more severe. For reducing the amount of air leakage, doors should be well-sealed. However, the use of roller shutters could allow uncontrolled air infiltration as they have a gap at the top (as the diameter of the roller increases when the shutters are closed). The level of air leakage in warehouses is 15.0 m3 per hour for each m2 of envelope area at 50 Pa reference pressure difference, for good practice factories and warehouses, and 3.5 m3 per hour for each m2 of envelope area at 50 Pa reference pressure difference for best practice ones (Webb and Barton 2002). Some warehouses are refrigerated due to the nature of the goods stored. These have far greater energy consumption and the refrigeration accounts for the majority of the energy used in these buildings. Lighting and daylight control Lighting in warehouses is usually high pressure sodium lamps, achieving 150 lux (McEnvoy and Dye 2008, p. 267). Higher lighting levels are only required in dispatch and office spaces. Depending on the nature of the goods stored, the amount of solar gains should also be kept to a minimum to keep the goods fresh. In order to reduce the amount of solar gain, yet providing
© Woodhead Publishing Limited, 2010
576
Materials for energy efficiency and thermal comfort in buildings
enough natural light into warehouses, north-light roof designs and light-pipes are now often incorporated into the overall design of warehouses. Heating requirement and systems In older buildings, insulation levels are lower, and air leakages are high. A high proportion of convective heat will be lost through fabric, so radiant heaters would be more effective. However, these often lead to overheating. Radiant heaters are also energy intensive and result in very high fuel bills. With warm air systems, warm air tends to be collected beneath the roof, where it is not needed (see Fig. 23.6). There are now also warehouses that use transpired solar cladding for low temperature heating. Also known as Solarwall, this usually involves a dark perforated cladding that absorbs most of the solar energy; outside air is drawn through small holes in the cladding and is heated as it travels through the cavity behind the cladding and into the building. An example of this is the Sainsbury Distribution Centre in Pineham, UK, built by ProLogis. This type of heating system is particularly suitable for buildings with high ceilings and large indoor spaces, and could be used to offset the heating load of an existing warm air system. Solar thermal arrays are also being used in some of these state-of-the-art warehouses, to maximise the use of the solar energy reaching the building.
23.4.2 Typical construction A typical form of building for factories and warehouses is the mediumspan shed, and the use of steel and pre-cast concrete frame and lightweight cladding remains the norm. For lower cost installations, the use of three-layer
Warm-air system
Radiant heating system
23.6 The collection of heat for a warm-air system and a radiant heating system.
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
577
construction: inner liner panel, insulation (in quilt form or higher density batts) being loose laid between it and the outer plastic coated profiled sheet, is the vernacular solution (Architects’ Journal 1990). Summertime condensation is a particular problem for a three-layer cladding system. On hot humid days, the night-time air temperature will drop considerably, especially when the skies are clear. The outer surface could drop significantly and the moisture-laden air trapped within the corrugated outer sheet may condense at the back of the cold outer cladding. This can soak the insulation, making it less effective. A solution to this could be placing a breather membrane to the outside of the insulation, to allow moisture from within the building to escape (see Fig. 23.7).
23.5
Embodied energy
Apart from the operational energy that commercial buildings use, the embodied energy in their construction and maintenance is also becoming a more significant issue. Traditionally, the construction industry has not given much consideration to the embodied energy of a building, because this is relatively insignificant compared to the operating energy for the building over its lifetime. As a result, most effort has been put into reducing operating energy by improving the energy efficiency of the building envelope and educating occupants to switch off lighting and appliances when they are
Three-layer insulated profiled sheet outer panels and internal liner panels
Breather membrane
Cold formed steel purlin
23.7 The vernacular construction for warehouses: the three-layer construction with breather membrane to prevent condensation.
© Woodhead Publishing Limited, 2010
578
Materials for energy efficiency and thermal comfort in buildings
not in use. However, research in Australia (Tucker et al. 1993) has shown that as the operational energy reduces steadily, the proportion of embodied energy (including energy required for maintenance) becomes more significant. It could take many years before the cumulated operational energy reaches the same level as the cumulative embodied energy (including energy for maintenance). This is particularly true if the building is efficient and has low operation energy. Figure 23.8 shows an example from an office building in Australia, where it could take 50 years of low level operation to reach the same total amount of cumulative energy as the embodied energy.
23.5.1 Embodied pollution As well as embodied energy, building designers should also consider embodied pollution, which is caused during the manufacture of building components, and also its transportation to site. This is a controversial area, and where the pollution is a major issue, emissions are controlled by legislation and by bodies like the Environmental Agency and HMIP. In general, the use of the precautionary principle is recommended, in that materials should be selected to perform the task set while minimising all impacts including pollution.
23.6
Material choice
Modern commercial buildings in the UK typically have steel or concrete structures, with curtain walling using glass or panel a popular form for the
30
Cumulative life cycle energy of example office building
Cumulative energy (GJ)
25 20 Low operation energy
15
Normal operation energy High operation energy
10
Embodied energy
5 0
0
10
20 30 40 Years since completion
50
23.8 Comparison of cumulative life cycle energy for an office building.
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
579
façade. Environmentally, there are ongoing discussions to the benefits of steel or concrete over the other.
23.6.1 Advantages and limitations: steel versus concrete Steel and concrete frame buildings constitute the majority of office buildings in the UK (British Steel 1995, Clarke and Somerville 1992, Edwards and Hyett 2002, Stevenson and Spooner 1992). Compared to concrete, steel has up to 20 times more embodied energy as a result of its highly intensive production process. This also leads to very high embodied pollution, about 60 times more CO2 than the process for concrete. However, steel is relatively stronger than concrete, and the mass of steel used in steel structures is very much less than the mass of concrete used in concrete structures, so the actual difference between the amounts of embodied energy is not as great; also steel structures are easily demountable, and so are easily recycled or re-used. In construction, the recyclability and reusability of steel is extremely high, where between 95% and 98% of the steel used is re-used or recycled. The steel industry often argues that the initial embodied energy of the structure actually represents a very small proportion of the building’s total energy consumption in its lifetime. In comparison, the largest amounts wasted from buildings are concrete, aggregates, blocks and bricks, while the process of recycling concrete is still in the early stages of development. Concrete structures require steel reinforcements, but these are usually made entirely from recycled steel. Thermal mass Apart from the comparison of embodied energy, embodied pollution and recyclability, there is another important criterion to compare the performance of steel and concrete structures: the disposition of thermal mass. For passive or hybrid ventilation strategies, the ability of the building fabric to store thermal energy is essential in controlling and stabilising the indoor temperature. Buildings that are particularly susceptible to summer overheating, such as office buildings, would benefit greatly from this strategy; and the use of a heavyweight material like concrete, which has a large thermal capacity, would delay the time when the heat is transferred into the building by up to 6 hours, resulting in a reduction of peak internal temperatures by 3–4 °C. Although steel also has a high density, it is not used in as much quantity as concrete, and also its thermal capacity is about half that of concrete. For thermal storage to perform effectively, the materials with high thermal mass should be visible to a large area within the room. This usually means the soffit of the concrete slab. To increase the surface area of the soffit, corrugated forms of concrete construction are sometimes used. The troughs
© Woodhead Publishing Limited, 2010
580
Materials for energy efficiency and thermal comfort in buildings
and coffers provide greater surface area. The use of thick carpets and false ceilings should be avoided for effective use of thermal storage. The steel industry suggests that the thickness of thermal mass is not as important as previously thought (McEnvoy and Dye 2008). A concrete slab, exposed on one side, need only be 75–100 mm to be effective, and slabs of greater depth may reduce its performance as it becomes more difficult for the heat stored deep inside to be extracted for night cooling. The argument is that light steelwork constructions can still have efficient thermal mass, as the whole construction would still consist of a sufficient amount of concrete.
23.7
Modelling and monitoring thermal performance and comfort
When commercial buildings are in their design stage, it is necessary for designers to know how the geometry of the design and the materials chosen will affect the final thermal and energy performance of the building. Previously designers used tools for manual calculations such as the LT Method (Baker and Steemers 1996) and the CIBSE Building Energy Codes (CIBSE 1999a, 1999b) for estimating the performance of their design, and also to improve upon earlier designs. With the advance in computer software programs, it is now relatively simple to run building simulations using packages such as IES Virtual Environment, TAS, Energy Plus and ECOTECT to do the same task with more ease and greater accuracy. The Building Regulations also require non-domestic buildings to meet carbon targets, similar to the Code for Sustainable Homes (DCLG 2008) for domestic buildings, and SBEM (Simplified Building Energy Model) is the Building Research Establishment (BRE) approved default program.
23.7.1 SBEM Under the amendments to the UK Building Regulations, Approved Document L2A in 2006 (DCLG 2006), new non-dwellings have to meet carbon targets based on a whole building energy calculation. This allows designers more flexibility in their design, but at the same time, they also need to meet, wherever practicable, the worst acceptable standards or ‘limiting values’ for the following: ∑ envelope insulation ∑ air permeability ∑ efficiency of building services. Designers will also be required to confirm the absence of summer overheating, demonstrate the quality of construction and commissioning, and confirm the provision of information to the owner/occupier.
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
581
As for the whole building calculations, carbon emissions, based on 2002 standards for various elements, are first calculated for a notional building. A notional building is one that has the same size and shape as the actual building, and each space contains the same activity, so the activity schedules and parameters are equivalent to the actual space in the design. Then, placed in the same orientation and using the same weather data as for the design building, it goes through SBEM (Simplified Building Energy Model), the BRE approved default method for calculation, to calculate the Target Emission Rate (TER). The same process is then applied to the actual design, and a Building Emission Rate (BER) is produced. BER must be equal to or less than TER for the design to be approved. The use of SBEM automatically generates the ‘notional building’ from the data for the ‘actual building’. It calculates the appropriate improvement factor and shows whether or not a building meets the Building Regulations carbon target compliance test. It can show the effect on the compliance of different design decisions. However, it should be noted that it is not a design tool and does not prove that a design will work in practice. SBEM is required for both compliance with the Building Regulations and also Energy Performance Certificates (EPCs), but according to the EU Energy Performance of Buildings Directives (EPBD) Article 10, SBEM must be used in an independent manner, and by qualified and/or accredited experts. Therefore, there is a need to train people in the expertise to use SBEM.
23.7.2 Fingerprinting Although there is plenty of guidance when it comes to designing buildings and building services, the ultimate test that a building needs to pass is one of satisfaction by its end-users. Occupant feedback is usually obtained by conducting a questionnaire survey. Levermore has devised a double-Likert scale for occupants to rate 22 to 24 factors relating to the interior environment and the organisation (Levermore 1998). A seven-point scale is used for each factor, and as well as how much the occupant likes the factor in the working environment, they are also asked to rank how important this factor is to them (see Fig. 23.9). The importance score is then transformed by adding 4 to all values, and the product of the two scores is then normalised. The average scores for the factor for all the respondents then form the fingerprint for the building. Figures 23.10 and 23.11 show examples of fingerprints for real buildings including their overall average score. Each building will have its own unique fingerprint and also an overall score. The overall score could be positive or negative. A successful building, with its occupants mostly satisfied should achieve a high positive score, whereas a negative score usually denotes the occupants are dissatisfied with
© Woodhead Publishing Limited, 2010
582
Materials for energy efficiency and thermal comfort in buildings How important is this in the design of your ideal office? Unimportant Important
Do you like the… Dislike
Like
–3 –2 –1 0 1
1. noise level
2
3
–3 –2 –1 0
1
2 3
Comments:
23.9 An example of the double-Likert scale for a building performance criterion. Deep plan office with atrium and underfloor ac. Fingerprint of ranked scores (overall score = –17%)
60 50 40
20
–30
Appearance
General
Colleagues
Space
Daylight
Management
Health
Attractiveness
Colour
Glare
Lighting
Draught
Ventilation
Freshness
Smell
Humidity
Temperature
VDU/desk glare
–20
Window distance
–10
Noise
0
Control
10 Privacy
Score (%)
30
23.10 Building fingerprint for a deep-plan office with atrium and underfloor air conditioning.
many aspects of the building. The fingerprint also gives information about which aspects of the building are working well, and which need improving. Although currently not used in conjunction with TER and BER in the latest Building Regulations, fingerprinting allows users and designers to know precisely the positive and negative aspects of a building.
23.7.3 Sensors The use of post-occupancy sensors will also monitor how the building is performing thermally when it is in use. Ideally designers should be on-hand to monitor how the building is run for a few years after its completion, to ensure that it is being run the way it was intended. Too often, due a lack of understanding by the occupants of the environmental strategies and/or
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
583
Deep plan, modern, naturally ventilated building. Fingerprint of ranked liking scores (overall score = –15%) 40 30 20
–40
Space
Appearance
Daylight
Colleagues
Management
Smell
General
Window dist
Colour
Attractiveness
Noise
Health
Lighting
Freshness
C/lighting
Humidity
Ventilation
Glare
C/vent
Temperature
–30
Privacy
–20
Draught
–10
C/heating
Score (%)
0
VDU/desk glare
10
–50 –60 –70
23.11 Building fingerprint for a deep-plan, modern, naturallyventilated building.
controls of the HVAC systems, commercial buildings use far more energy than was intended by the designers. For larger buildings, the installation of a Building Energy Management System (BEMS) is highly recommended. In BEMS, sensors are also required to monitor the conditions of the building, and appliances are switched accordingly. Movement sensors in warehouses are also common, so lighting is only switched on when there are people about. Delivery doors may also be electrically operated, so they are not left open when not being used. Under the EU Energy Performance of Buildings Directives (EPBD), since October 2008, public buildings in the UK have to put up Display Energy Certificates (DECs) (Davidson 2007) for users to see. These show the energy potential of the buildings and compare this to how much the buildings actually use. DECs are a good way for the occupiers and users of public buildings to know how much energy their building is using, and what can be done to achieve its full potential. Perhaps this scheme should extend to other nondomestic buildings, especially offices, and not just public buildings.
23.8
Future trends in design and refurbishment
Due to their nature, commercial buildings often use more energy than they require, but there are existing technologies that can be implemented to reduce this energy usage significantly (Levermore 2008). An important aspect often overlooked is the quality of workmanship. If buildings are not
© Woodhead Publishing Limited, 2010
584
Materials for energy efficiency and thermal comfort in buildings
actually built to the standard specified by the designers, for example, if they are too leaky, then the thermal performance will suffer. One way to improve this would be to increase the amount of factory-made building components. The increase of pre-fabricated components will minimise the amount of time spent on site and thus reduce the possibility of low-quality workmanship when components are put together. This implies designers spending more time at the drawing table, like in Japan, where the time spent on designing is three times as much as the UK, but the time spent building on site is only a third of the time in the UK (Xiao and Proverbs 2003). Controlling and monitoring the amount of energy used is another vitally important aspect that all commercial buildings should employ. With the advancements in wireless technology, it should be much simpler to set up Building Energy Management Systems (BEMS) so buildings are controlled and run properly and efficiently. The ability to use thermal mass to store up heat should also be explored more. As well as exposing concrete elements, and reducing the use of false ceilings and carpets where possible, future buildings can also make use of phase-changing materials (PCM). These could be micro-encapsulated paraffin with a melting temperature of between 25 °C and 28 °C, and can be mixed into gypsum plaster which can then be plastered onto walls as conventional plaster. The simple use makes the material especially suitable for the renovation of existing buildings. The melting temperature coincides with the temperature when a building gets too hot. As the paraffin melts at this temperature, it absorbs latent heat from the room, thus reducing the air temperature of the room. At night time, when the temperature falls below its solidifying temperature, latent heat from the paraffin in its liquid state is released as it solidifies, warming the air in the room where it is located. As well as paraffin, some salt hydrates with a melting temperature between 25 °C and 32 °C can also be used. These dispose of a significantly greater amount of latent heat than paraffin. As the micro-encapsulation of salt hydrates poses a problem due to the increase in volume during the melting process, it is more suitable to put them in macro-elements such as flat containers or tubes rather than mixed in with plaster. Such macro-elements filled with salt hydrate can be put in suspended ceilings, which allows their application in the refurbishment of older buildings. Figure 23.12 and 23.13 show the effects of using PCM in a control room in plaster form and as a salt hydrate, respectively. This is from an experiment conducted by Hoffmann et al. in Germany. The maximum room temperatures are reduced by 2–3 °C, and the minimum room temperatures increased by approximately the same amount in the plaster form; with a salt hydrate as PCM, the reduction in maximum room temperatures are even greater, at around 5–6 °C. As well as trends in the design and refurbishment of commercial buildings for the future, there are also trends and predictions to how building materials
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
585
45 40
Temperature (°C)
35 30 25 20 15 10 29/5/04
30/5/04 Date of experiment
31/5/04
23.12 Measured room temperatures with PCM-plaster (dashed line) and without PCM-plaster (black line). 40
Temperature (°C)
35 30
25 20 15 10 3/10/04
4/10/04 Date of experiment
5/10/04
23.13 Measured room temperatures with additional salt hydrate (grey line) and without PCM (black line).
will advance and changes to how commercial buildings will be used. Already there have been significant improvements in glass technology to produce glazing that allows in light, but prevents a large amount of heat and solar radiation entering a building. Commercial buildings generally uses a lot of glazing and the continued advances in glass technology will help reduce the
© Woodhead Publishing Limited, 2010
586
Materials for energy efficiency and thermal comfort in buildings
growing need for mechanical summer cooling as a result of climate change. The growth of wireless technology and advances in the energy efficiency of office equipment and lighting will also reduce the amount of internal gains. There is also a growing trend towards a more relaxed dress code for office workers, which increases the level of adaptability by workers to change their level of clothing. More people being allowed to work from home also means less energy wasted on journeys to work, and again less internal gains with fewer occupants inside the building. For retail spaces, there is also a growing trend for online shopping, which may result in fewer shopping centres. The number of warehouses may also be reducing, as better planning and management of manufacturing process mean products could be made and delivered more efficiently, cutting down the number of goods and the time they spend in warehouses.
23.9
Sources of further information and advice
Carbon Trust (2000) Energy Consumption Guide 19 – Energy Use in Offices, Action Energy/The Carbon Trust. CIBSE (2000) CIBSE: Guide H: Building Control Systems, Chartered Institution of Building Services Engineers, London. CIBSE (2004) CIBSE: Guide F: Energy Efficiency in Buildings, Chartered Institution of Building Services Engineers, London. CIBSE (2006) CIBSE: Guide A: Environmental Design, Chartered Institution of Building Services Engineers, London. Energy Efficiency Best Practice Programme (1994) Introduction to Energy Efficiency in Shops and Stores, Department of the Environment, UK. Energy Efficiency Best Practice Programme (2004) Guide 18 Energy Efficiency in Industrial Buildings and Sites, HMSO, May. IPCC (2007) ‘Intergovernmental Panel on Climate Change (IPCC) Fourth Assessment Report (AR4)’, WMO, UNEP. McEnvoy, M. and Dye, A. (2008) Environmental Construction Handbook, London, RIBA Enterprises. Prior, J. (1999) Sustainable Retail Premises: An Environmental Guide to Design, Refurbishment and Management of Retail Premises, BRE, Watford.
23.10 References Architects’ Journal (1990) ‘Light Industry Passive Solar Factories’, Architects’ Journal, 31 January 1990, p. 59. Baker, N. and Steemers, K. (1996) ‘LT Method 3.0 — a strategic energy-design tool for Southern Europe’, Energy and Buildings, 23(3), 251–256. Baldwin, R., Yates, A., Howard, N. and Rao, S. (1998) BREEAM 98 for Offices, Building Research Establishment, Watford.
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
587
Bordass, W. (2001) Flying Blind: everything you wanted to know about energy in commercial buildings but were afraid to ask, EEASOX and the Association for Conservation of Energy, London. British Steel (1995) Ecobuild in Steel, Scunthorpe, Marketing Dept, Redcar. Carbon Trust (2000) Energy Consumption Guide 19 – Energy Use in Offices, Action Energy/The Carbon Trust. Chow, D.H.C. (2005) ‘The Effects of Future Climate Change and Near-Extreme Weather on Office Buildings in the UK’, PhD Thesis, University of Manchester. Chow, W.K. and Fung, W.Y. (1995) ‘Indoor Thermal Environment Survey in AirConditioned Shopping Malls in Hong Kong’, Indoor and Built Environment, 4(2), 102–112. Chow, D.H.C. and Levermore, G.J. (2007) ‘New algorithm for generating hourly temperature values using daily maximum, minimum and average values from climate models’, Building Services Engineering Research and Technology, 28(3) 237–248. Chow, D.H.C., Levermore, G.J., Jones, P., Lister, D., Laycock, P.J. and Page, J. (2002) ‘Extreme and near-extreme climate change data in relation to building and plant design’, Building Services Engineering Research and Technology, 23(4), 233–242. CIBSE (1999a) CIBSE Building Energy Code 1: Energy Demands and Targets for Heated and Ventilated Buildings, Chartered Institution of Building Services Engineers, London. CIBSE (1999b) CIBSE Building Energy Code 2: Energy Demands for Air Conditioned Buildings, Chartered Institution of Building Services Engineers, London. CIBSE (2006) CIBSE: Guide A: Environmental Design, Chartered Institution of Building Services Engineers, London. Clarke, M. and Somerville, G. (1992) ‘Concrete in the Environment’, Concrete Quarterly, Winter. Clements-Croome, D. (2003), ‘Environmental quality and the productive workplace’, paper presented at CIBSE/ASHRAE Conference. Building Sustainability, Value and Profit; Edinburgh, Scotland, 24–26 September 2003. Cohen, R.R., Munro, D.K. and Ruyssevelt, P.A. (1993) ‘Over heating criteria for non air-conditioned buildings’, CIBSE National Conference, UK. pp. 132–142. Da Yong (2004) ‘Shanghai seeks to switch off light pollution’, China Daily Newspaper, 12 April. Davidson, P. (2007) ‘The energy performance of buildings directive’, Reducing the Carbon Footprint in the Built Environment, Institution of Engineering and Technology Seminar, London. DCLG (2005) Planning Policy Statement 6: Planning for Town Centres (PPS6), Stationery Office. DCLG (2006) ‘Building Regulations – Part L Building Regulations – Conservation of Fuel and Power’, NBS/RIBA Enterprises. DCLG (2008) Code for Sustainable Homes – Summary of Changes to the Technical Guidance, April, Stationery Office. DETR (1998) The Impact of Large Foodstores on Market Towns and District Centres, HMSO, September, p. 1. Edwards, B. and Hyett, P. (2002) Rough Guide to Sustainability, RIBA, London. Energy Efficiency Best Practice Programme (2004) Guide 18 Energy Efficiency in Industrial Buildings and Sites, HSMO, May, p. 1. Jones, P. (1990) ‘Low-Energy Factories: 1 Setting Priorities’, Architects’ Journal, 16 May, p. 65.
© Woodhead Publishing Limited, 2010
588
Materials for energy efficiency and thermal comfort in buildings
Levermore, G. (1998) Occupant Feedback using a questionnaire rating liking and importance of up to 24 factors. Available at: http://www.inive.org/members_area/ medias/pdf/Inive%5Cclima2000%5C1997%5CP326.pdf (accessed 28 May 2008). Levermore, G. (2008) ‘A review of the IPCC Assessment Report Four, Part 1: the IPCC process and greenhouse gas emission trends from buildings worldwide’, Building Services Engineering Research and Technology, 29(4), 349–361. Male, S., Gronqvist, M. Kelly, J. and Damodaran, L. (2003) Supply Chain Management for Refurbishment: Lessons from High Street Retailing, Thomas Telford Ltd, London. McEnvoy, M. and Dye, A. (2008) Environmental Construction Handbook, London, RIBA Enterprises. The Movement for Innovation (2001) ‘The Movement for Innovation Sustainability Working Group Report, Environmental Performance Indicators for Sustainable Construction’, p. 17. Ohsaki, H. and Kokubu, Y. (1999) ‘Global market and technology trends on coated glass for architectural, automotive and display applications’, Thin Solid Films, 351(1–2), 1–7. Prior, J. (1999) Sustainable Retail Premises: An Environmental Guide to Design, Refurbishment and Management of Retail Premises. BRE, Watford. Stevenson, J. and Spooner, D. (1992) ‘Concrete and the environment’, Concrete Quarterly, Autumn. Tucker, S.N., Salomonsson, G.D., Treloar, G.J., MacSporran, C. and Flood, J. (1993) ‘Environmental Impact of Energy Embodied in Construction’, Report prepared for the Research Institute of Innovative Technology for the Earth, CSIRO, Highett, Victoria. Webb, B.C. and Barton, R. (2002) ‘Air Tightness in Commercial and Public Buildings’. BRE Press, Office of the Deputy Prime Minister. Xiao, H. and Proverbs, D.G. (2003) ‘Contractor relationships: a comparison in Japan, the UK and the US’, Journal of Construction Procurement, 9(2), 52–64. Yang, W. and Zhang, G. (2008) ‘Thermal comfort in naturally ventilated and airconditioned buildings in humid subtropical climate zone in China’, International Journal of Biometeorology, 52(5), 385–398.
© Woodhead Publishing Limited, 2010
24
Materials for energy efficiency and thermal comfort in high performance buildings
P. C. J. D a v d a , G. S e x and J. B r o o m f i e l d, The Austin Company of UK Ltd, UK
Abstract: Requirements of energy capacity, human occupancy and specialist conditions required are now far more demanding than in the past and, with it, the challenges and opportunities to control the amounts of energy and materials required – this is not the end of the line on the debate for energy, efficiency and selective use of the earth’s resources, but just the beginning! This chapter reviews facilities that require close control of temperature, relative humidity, air cleanliness and room pressure regimes to control the environment where manufacturing, research and quality control activities can be undertaken on a repeatable basis. Generally these facilities are required to comply with good manufacturing practice (GMP) and good laboratory practice (GLP). It discusses facilities generally found in pharmaceutical, life sciences, biotechnical, electronics technology, food, aerospace, universities and institutional or government departments. Subsequent discussions lead to choices of components and materials for energy efficiency and strategies for assessing the benefits or not of incorporating environmentally aware and/or energy reducing opportunities into such buildings, whilst taking into account the specialist nature of the facility and the specific energy requirements. This leads to categorising the selection of materials relating to payback periods, a review on BREEAM and future trends. Key words: classified research facilities, good laboratory practice and good manufacturing practice, containment and clean room facilities, environment and energy considerations, sustainability and BREEAM.
24.1
Introduction
High performance industries and their facilities are those which require close limits of temperature, relative humidity and air cleanliness with perhaps room pressure regimes to control the environment whereby manufacturing, research and quality control activities can be undertaken in a controlled area on a repeatable basis. To ensure that the facility environment meets the specified controlled conditions, a validation process is generally undertaken for the design, installation and operational stages. The validation process commences from verifying the user requirements by carrying out a Design Qualification (DQ), followed by an Installation Qualification (IQ), Operation Qualification (OQ) 589 © Woodhead Publishing Limited, 2010
590
Materials for energy efficiency and thermal comfort in buildings
and Performance Qualification (PQ).1,2 This gives assurances that the four stages of validation match the initial user requirements and the master plan. Generally these facilities are also required to pass specific minimum tests complying with standards such as good manufacturing practice (GMP)3 and good laboratory practice (GLP).4 Typical of the industries which are required by law, convention or competition to operate with these types of facilities are pharmaceutical, life sciences, biotechnical, electronics technology, food, aerospace, universities and some institutional or government departments. There are numerous governmental regulations to be met. The choices of components and materials for energy efficiency are many and varied and it is the designers who have to negotiate and incorporate the appropriate solutions put forward by the various interested parties. Although all of the groups having input will agree that energy efficiency is important, there are sometimes conflicts of interest that may arise due to specific functions the facility has to meet: ∑ ∑ ∑ ∑ ∑ ∑ ∑ ∑ ∑
∑
The User is paramount in specifying the needs of the building to suit his/her required environment to produce the output required, quite often within a tight programme. The Architect requires the building to function for the people and products and also look aesthetically pleasing. The Building Services Engineers incorporating Mechanical, Electrical and Public Health, require construction materials and methods which are able to support the internal environment and processes. The Civil and Structural Engineer must ensure that the building framework is sound and safe for the loads involved. The Construction Team must check that the materials used and the details of construction are effectively buildable and the quality required and specified is achievable. The Financier requires a solution which makes a return on capital over a given period and gives value for money. The Maintenance Engineer requires a robust system of components that require minimum maintenance with safe practices. The Planning Process will approve a building which matches their development plan for the needs of the community and blends with the outdoor environment. The Building Regulations require stringent reviews of materials to meet the legal thermal requirements, and to ensure the facility is safe, structurally sound, fire resistant and has minimum health and safety risks. The Regulatory Agencies require, on behalf of worldwide governments, that legal standards are met for many of these high performance facilities,
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
591
which include cleanliness, containment and, above all, operational safety. The environmental conditions within the facility are created by the mechanical and electrical systems. Efforts are made to reduce energy use by minimising heat loss and gain through the fabric, reducing the amount of outdoor air introduced into the supply air system, heat recovery systems, reducing electrical needs, using efficient components (fans, chillers, pumps, etc.) and ensuring that energy use is reduced when there is no need for the facility to be fully operational. Computer modelling is a technique which is now used by professionals to help understand and design buildings where the complexities of the systems and components can be measured to identify projected energy use and carbon emissions and these analyse and compare the building’s efficiency. In the future the demands for greater energy conservation will increase. Refurbishment of existing facilities may help by reducing the amount of new build. Meeting the ever increasing regulatory standards of the environment and the ever reducing availability of land and energy may promote refurbishment of existing facilities. However, the same in-depth analysis of design requirements has to be undertaken. There is no short cut to success. In the design and construction of these buildings, it is important to remember that, whilst the requirement for a facility which is highly energy efficient and utilises renewable energy and sustainable materials is a desirable aim, the building will have specific functions to perform. If the performance of those functions is compromised or, indeed, if the necessary regulatory requirements for any such functions cannot be met, then effectively the building becomes useless. This chapter discusses the issues involved and how some of the energy saving needs may be answered for high performance facilities.
24.2
User considerations
The types of specialist environments are many and varied, and are often categorised depending on the specific tasks to be undertaken. For example, in the pharmaceutical, healthcare and related industries there are many types of facilities designed specifically to undertake research and development (R&D), quality assurance (QA), quality control (QC), analytical, chemistry, biological, radioactive work, etc., pilot plants, manufacturing, life sciences, automated robotic facilities such as ultra high-throughput screening (UHTS). The type of facility required is directly related to the perceived need of the user’s organisation. This is true also of the quality of the facility, the monies available to obtain and run the facility and the urgency of when the facility is required and its projected time in use or life span (quality, cost
© Woodhead Publishing Limited, 2010
592
Materials for energy efficiency and thermal comfort in buildings
and time). In addition to these criteria, there are also the emerging trends towards alternative energy sources (the European Union has set objectives regarding low carbon energy efficient economy), sustainability, life cycle costing (or whole-life costs – the total cost of ownership over the life of an asset) and life cycle assessments (the investigation and valuation of the environmental impacts of a given product or service caused or necessitated by its existence).5 Coupled with the above requirements, further considerations when designing specialist environments are whether the new facility is conceived as a new building or is within an existing building that will be refurbished or re-modelled. This is particularly influential to the design of specialist environments. By using existing buildings, there could be quite onerous restrictions placed on any future design, for example, specialist environments by their very nature are often highly serviced. Existing buildings may not have the space for running large amounts of duct or pipework, particularly in ceiling voids, thereby often necessitating inefficient compromises. As noted above, the type of client organisation can have a bearing on the time, cost and quality of the specialist environment to be provided. These could include the following. Public/commercial companies Getting the new facility into operation in the shortest possible time is usually of very high importance, so that early financial benefit arising from the output of the new facility is achieved as soon as possible in order to satisfy shareholders. The extent of monies available to provide new facilities varies considerably between organisations and the activities that they undertake, and as will be discussed later, is not just about the provision of the basic facility, but also the wider working environment in order to, for example, attract the highest calibre workforce. Often the facilities provided are relatively short lived, for example they may only be required to produce a specific patented drug over a period of a few years until the patent runs out at which point other manufacturers could then start producing similar products, such as generic drugs.6 The next patented drug to be produced may well require different equipment, environment and processes, thus necessitating the redevelopment of the facility. R & D is a big part of what a number of the major pharmaceutical organisations do, and by the nature of the research undertaken, is often ‘cutting edge’. Therefore the facilities required to undertake this sort of work have to be capable of providing environments for a wide range of activities, often very specialised. Because of their specialised nature these types of buildings are often some of the most expensive facilities to procure, both in terms of capital cost and time, from commencement of the design to the
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
593
24.1 Research and development facility building for large UK-based commercial pharmaceutical company.
facility opening. Figure 24.1 shows an R & D facility building for a large UK-based pharmaceutical company. Universities Money available to invest in new facilities at universities and schools is often very limited. Sometimes limited amounts of money become available from grants given, for example, by established organisations, or through government funding or private sponsorships. The types of facilities often provided have not only to be very cost effective, but often need to be multi-functional to cater for a wide range of training needs, and also to be constructed to provide facilities with a relatively long lifespan. The nature of these facilities therefore, tends to be relatively basic, as a lot of the teaching work undertaken is of a more general and less onerous nature. However, there are some exciting developments currently happening in this area, which include the large, multi-functional, multi-media teaching laboratories (Fig. 24.2). One challenge within the teaching sector when refurbishing facilities is the requirement for this to take place during periods when the school or university is closed. This often requires extensive work to be undertaken over the 8–10 week period during the summer recess. This can be a challenging factor and often influences the design of the works, including materials used.
© Woodhead Publishing Limited, 2010
594
Materials for energy efficiency and thermal comfort in buildings
24.2 University laboratory building.
Quasi-government A number of organisations are either linked to, or are related to government activities. In the UK there are many such organisations, often to be found in defence, research or those tasked with regulatory powers who preside over industry, such as the pharmaceutical, healthcare and food industries. These organisations benefit from grants or direct contributions from the government, public or industry. They tend to be some of the most sensitive type facilities, often dealing with research into diseases within both the human and animal worlds. The result of this is that some of these facilities are the most advanced, in order to deal adequately with the activities they undertake. However, although they may be at the forefront of specific research, they also often have limited monies with which to develop and run their specialist facilities. Often these facilities have a long life expectancy and will be required to be operational for many, many years. A further category of organisation is the research charities. There are many involved in highly specialist areas, such as cancer, leukaemia and other critical illnesses. These organisations are funded in a number of ways, such as through public donations and grants often from industry directly or indirectly. Their requirement for specialist environments and facilities is again often at the front end of understanding, allowing positive research. The facilities they require are often highly sophisticated and are often designed to portray an ‘image’ to the world, to show that the money they receive is being well used. Figure 24.3 shows a new research building for a leading UK cancer charity.
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
595
24.3 New research building for a leading UK cancer charity.
The one thread that brings all the above requirements together, whether specialist environments in the public/commercial, teaching or government sectors, is the issue of safety. All these facilities have to operate in a safe manner, and depending upon the activity undertaken, the scientist, machine operative, the general public, the natural environment, etc, must be adequately protected – there should be no compromise on safety.
24.3
External considerations
It is often desirable that the external structure of the facility gives little clue as to the process which is being carried out inside. For example, a building which has a forest of discharge stacks sprouting from its roof not only looks unsightly but can also attract unwanted attention (Fig. 24.4). In many fields the requirement to recruit the best available research scientists has lead to the need to make what were formerly process ‘sheds’ into pleasant looking buildings with comfortable working environments that encourage people to want to work there. It is therefore important to maintain a balance between the more enclosed or concealed process functions and the outwardly visible and pleasingly aesthetic people areas. Buildings containing highly specialised environments are often conceived as a traditionally constructed building externally with the specialist facilities located within, sometimes broadly referred to as ‘a building within a building’ concept. The external perimeter of such buildings can often be treated like any other industrial building, where orientation, massing, protection from heat loss, solar gain (either beneficial or unwanted), choice of materials, energy
© Woodhead Publishing Limited, 2010
596
Materials for energy efficiency and thermal comfort in buildings
24.4 Flue stacks can be a an obvious feature of the skyline for some specialist buildings.
conservation considerations and overall aesthetics, can all contribute to the overall energy efficiency and comfort as well as responding to the issues relating to sustainability and alternative sources of renewable energy. With such specialist buildings, additional requirements for the external envelope may also be required depending on the building’s usage. These could include: enhanced security requirements, improved fire performance, blast resistance and electromagnetic pulse protection (EMP) and, sometimes, provision for internal explosion and overpressure protection. Suitability of materials and design philosophies to achieve increased energy efficiency and comfort in buildings generally is discussed elsewhere. However, when it comes to the design of the external fabric of a building associated with highly specialist environments, then the particular choice of materials and design philosophies do need to be very carefully considered in relation to the specialist nature of the activities to be undertaken within the building. As an example, some current approaches to sustainability, energy conservation and environmental considerations now include timber cladding and the use of natural planting on the building, such as green roofs and walls – also known as living roofs and walls. Green roofs or walls are completely, or in part, covered with vegetation and in some instances soil. The benefits include increasing thermal mass and insulation of the envelope of the building (thus reducing the need for mechanical heating and cooling) and reducing stormwater runoff, in turn reducing risks of flooding and potential need of pumping. They also help to filter carbon dioxide and pollutants out of the air,
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
597
improve sound insulation, provide pleasing and ‘contextual’ aesthetics and also provide provision for additional wildlife habitat – the last few reasons particularly suited to buildings that are to be located in visually sensitive and/or rural areas. If green roofs or walls are to be considered for a building containing specialised environments, then there is a potential for increasing the risk of animal or insect infestation within the facility. There is some concern within the industry at present that this type of ‘green design’ may not be compatible with ‘high technology’ controlled environments, in particular those dealing with microbiology, as the potential for compromising the highly controlled environments within could exist. Most buildings containing specialist environments require either their external fabric, or the surrounding fabric of the internal critical areas, to be sealed to prevent air, bacteria, etc., escaping and to prevent dirty untreated air, insects and other potential contaminants from entering, and to allow the internal environments to be appropriately sealed for fumigation purposes. Timber cladding, green roofs and green walls, by their very nature, attract many forms of wildlife such as birds, insects and plant life. This is indeed one reason why they are used. However, the effect could result in an unacceptable increased risk of potential pest infestation or contamination control issues, with the need to then provide additional measures to prevent such infestation within the building (i.e. from flies, spiders, airborne pollen, etc.). It should also be borne in mind that the use of green roofs and walls could also increase the size of the building’s structure to support the additional weight of planting, soil and the retained water that occurs with these systems. There are some specialist environments that contain facilities requiring very special consideration, and with these, the basic construction of the facility, including structural frame and external envelope, are critical. In some instances, the ‘traditional’ considerations and approaches associated with the envelope of the building, such as heat loss and solar gain are not necessarily appropriate. For example, within some process facilities, the activity undertaken may consistently generate high levels of ‘unwanted’ heat within the building or could involve reactions that create a risk of deflagration or detonation.7 Facilities where high levels of heat are produced by the contained process are often designed to reduce heat build-up wherever possible. For example, external walls can be designed to include louvres to allow the heat to dissipate and are often uninsulated (traditional insulation in the external envelope would only increase the excessive heat build-up within the facility). Allowing the unwanted heat to pass out of the building through the external envelope reduces the amount of mechanical cooling that would otherwise be required, with a resulting reduction in energy consumption required to achieve the appropriate cooling. There may also be the option to recover and use the heat that is produced in the facility. The effectiveness of this,
© Woodhead Publishing Limited, 2010
598
Materials for energy efficiency and thermal comfort in buildings
and the benefit thus obtained compared to the costs involved to achieve this, would need to be considered carefully on a case-by-case basis. The choice of external materials to be used for roofs and walls will depend on many factors in addition to those discussed above. These could include: aesthetics (local Planning Authorities often need to be consulted), location of other adjacent buildings and land in different ownership, and requirements of the building’s insurance company which could be particularly onerous.
24.4
Internal considerations
Specialist internal environments by their very nature have predetermined criteria published through legislation, standards and industry guidance documentation that could affect their location within the building, the size, inter-relationship and adjacencies of these spaces in addition to their internal environmental conditions (air quality, temperature, humidity, lighting, etc.). All these criteria can vary depending on the type of facility and the work to be undertaken within it. With all of the external and internal considerations to be taken into account, there are often opposing requirements where the external considerations may clash with those of the internal requirements. Because of this, when designing such buildings, it is important to reach an acceptable degree of compromise between a pleasant working environment and regulatory compliance. By viewing the building as ‘process areas’, ‘support’ or ‘people areas’, the ability to resolve these apparently often opposing requirements through the use of different forms of energy sources and building systems becomes possible.
24.5
Process areas
For many specialist environments, it is both the choice and use of materials internally, and the mechanical air systems, that are the key to achieving the types of specialist and critical performances required. The types of specialist environments are wide-ranging and depend directly on the activities to be undertaken. There are many differing requirements, but two of the most common can be categorised under the headings ‘clean rooms’ and ‘containment facilities’: ∑
Clean room and associated environments. This type of specialist facility is used in industries such as aerospace, micro-electronics, pharmaceuticals, medical devices, food and healthcare. The need and type of such facilities differ between industries, but the main reason for the requirement is to protect the process or procedure being undertaken from risk of contamination. Generally clean room environments are designed to operate under positive pressure but may contain localised negative pressure areas where operator protection is required. © Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
∑
599
Containment and associated environments. This type of specialist facility is used in industries such as pharmaceuticals, healthcare, agriculture and animal welfare. The need and type of such facilities differ between industries, but the main reason for the requirement is to protect the surrounding environment (both inside and outside the building) including human, animal and plant life, together with the need to protect the operators or scientists within the facility, from exposure to potentially harmful (even life-threatening) substances, diseases or processes. Generally containment environments are designed to operate under negative pressure but may have positive pressure boundaries to prevent any external contamination from entering the facility.
Both categories could include R&D and manufacturing requirements. The type or level of clean room or containment environment required will depend on the nature of the work to be undertaken. The environments where such work is carried out are very heavily regulated and there are specific guidelines laid down governing the design and operation of such facilities. In most cases their use can only be undertaken under government licence. In the UK, for example, pharmaceutical manufacturing is governed by the Medicines and Healthcare products Regulatory Agency (MHRA) which is a government agency responsible for ensuring that medicines and medical devices work, and are acceptably safe.2,8 In the United States, the US Food and Drug Administration (FDA) undertake similar responsibilities.9 For a veterinary medical product to be placed on the market in the UK, an authorisation from the Veterinary Medicines Directorate (VMD), the licensing authority for the United Kingdom, is required.
24.5.1 Clean room facilities General clean room and associated controlled environments are classified in the UK and Europe by the International Organisation for Standardisation (ISO) Standards. ISO 14644 Parts 1 to 8 cover clean rooms and associated controlled environments. Part 1 provides classification of air cleanliness through the control of airborne particulate contamination to levels appropriate for accomplishing contamination sensitive activities.10 This standard identifies various classes of clean room and clean room zones, ranging from ISO Class 1 through to ISO Class 9, where ISO Class 1 is the cleanest environment. Each ISO Class stipulates the maximum concentration limits (particles/m3 of air) for a range of particle sizes from ≥0.1 mm to ≥5.0 mm. In the United States, the US Federal Standard 209E – Airborne Particulate Cleanliness Classes in Clean rooms and Clean Zones – is still widely referred to, although this particular guidance was withdrawn in 2001 in favour of the guidance outlined in ISO 14644. US STD 209E again uses particulate count to establish
© Woodhead Publishing Limited, 2010
600
Materials for energy efficiency and thermal comfort in buildings
differing Classes of clean room, namely Classes 1, 10, 100, 1000, 10 000 and 100 000 which broadly equate to ISO classes 3, 4, 5, 6 , 7 and 8. For the production of sterile medicinal products, under the responsibility of the MHRA in the UK, the clean room classifications identified within ISO 14644 have been further modified by the MHRA,8 to take into account specific concerns unique to the production of sterile medicinal products and EU Guidance on Good Manufacturing Practice (GMP).3,11,12 The classifications identified are referred to as Grade A, B, C and D (grade C and D being broadly equivalent to ISO Classes 7 and 8). There are differences in the end requirements between industries such as micro-electronics and pharmaceutical manufacturing. The micro-electronics industry tends to look for limitations in the number and size of any form of particle within their manufacturing facilities. The desire is to avoid particulate contamination of micro-circuitry which would increase the failure rate of such operations as silicon chip production. However, within the pharmaceutical industry, there is a desire to maintain sterility of the product by eliminating any particles which may reduce sterility by introducing bacteria into the product. It is therefore vital that materials used in the construction of these facilities do not contribute to the amount of free particulates within the air or harbour the growth of bacteria. Fibrous materials should be avoided such as carpets and exposed insulation. Depending on the class of clean room to be provided, materials that could give off particulates if knocked or damaged should also be avoided, such as plasterboard, fibre ceiling tiles and exposed wood. It is also critical that movement within materials, such as shrinkage or thermal movement is avoided to reduce or eliminate the risk of cracking of wall, ceiling or floor surfaces. Pharmaceutical clean rooms, for example, can typically be ISO class 7 or 8 with localised class 5 or higher environments being contained within specialist equipment, such as isolators13 or by providing laminar air flow across filling heads. For an ISO class 7 or 8 environment, internal wall finishes could typically include proprietary metal clean room wall and ceiling panel systems, seamless GRP coatings or welded sheet vinyl to walls and ceilings, specialist paint systems, welded vinyl sheet flooring with integral coved skirtings, and metal or GRP doors (Fig. 24.5). The choice of material and the details used to apply these materials needs to withstand other factors without compromising their inability to shed particles into the atmosphere. Surfaces and details should be smooth and ideally seamless to allow for ease of cleaning and to limit the risk of build-up of dirt or bacteria thus hindering the cleaning process. Horizontal surfaces should be avoided wherever possible, particularly at high level, where they are difficult to keep clean. Similarly, it is important to ensure that if gaps are unavoidable in the construction, then these are not mere cracks but are large enough to be accessed fully for cleaning (for example, between
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
601
24.5 Clean room environment with proprietary clean room partition and ceiling, welded vinyl flooring and flush glaze windows and escape door.
cupboards or equipment and adjacent wall surfaces). The room finishes need to withstand aggressive methods of cleaning together with movement and transportation of materials around the facility. In pharmaceutical manufacturing, for example, materials are often moved around on special GMP compliant pallets.14 Surfaces also need to withstand accidental spillage of chemicals or materials that are used within the facility. A further consideration could be the ability of the fabric which is used to construct the laboratory to withstand relatively high positive or negative pressure differentials within the room. Care should be taken when specifying and detailing these facilities that the pressure regimes are understood and designed for accordingly. For instance, ceilings may need additional rigid support systems to prevent them being pushed up by the positive pressure below and high negative pressures may create a tendency for rooms or room finishes to ‘implode’. In areas of pharmaceutical or micro-electronic production, it is also not uncommon to require a very dry atmosphere with relative humidity levels sometimes as low as 10% rh. In order to maintain these low humidity levels and to minimise the energy used to achieve them it is important to construct the facility with an adequate vapour barrier to prevent moisture vapour from being drawn through the building fabric by the high differential created between the low humidity area and the higher level present in the general surrounding areas. This can be achieved in many ways depending on the type of facility but could include an oil-based paint finish to plaster
© Woodhead Publishing Limited, 2010
602
Materials for energy efficiency and thermal comfort in buildings
walls, a foil-backed plasterboard lining to the room, or a fully welded sheet vinyl enclosure.
24.5.2 Containment facilities Biological containment and associated environments are controlled in Europe through the EC Biological Agents Directive (2000/54/EC) and in the UK specifically through the Control of Substances Hazardous to Health Regulations 1994 (COSHH). The Advisory Committee on Dangerous Pathogens (ACDP), appointed by the Health and Safety Executive in the UK, have published guidance on ‘The management, design and operation of microbiological containment laboratories’15 and this is now generally considered to be good industry practice. Although the guidance is not compulsory, by following its guidelines, it is generally recognised that enough is being done to comply with UK law. The ACDP guide identifies four specific categories for containment laboratories based on their application and the type of biological agent to be handled within the laboratory: ∑
Containment level 1 (CL1) laboratories – such as secondary education and undergraduate teaching laboratories. ∑ Containment level 2 (CL2) laboratories – broad range of clinical, diagnostic and research work. CL2 is the most numerous of containment level laboratories. ∑ Containment level 3 (CL3) laboratories – the highest containment level of laboratories commonly used within the UK. ∑ Containment level 4 (CL4) laboratories – very highly specialised and subject to very stringent requirements relating to their design, operation and management.
In the United States, similar guidance exists for containment facilities. The Centres for Disease Control and Prevention (CDC)16 publish similar guidelines for biosafety. Their publication ‘Biosafety in Microbiological and Biomedical laboratories’ again identifies four specific categories for containment laboratories within the United States, namely Biosafety level 1, 2, 3 and 4 laboratories. The requirement for materials used in the construction of containment laboratories is, in many respects, similar to the construction of clean rooms. They need to be resistant to the processes or materials including chemicals, that are (or could be) used within the facility. They need to be easily cleanable and construction details are to be robust and designed to prevent dirt buildup and to permit easy cleaning. Materials used within a containment laboratory are also likely to be required to withstand the effects of regular decontamination and/or fumigation, such
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
603
as the use of vaporised hydrogen peroxide (VHP) or formaldehyde vapour. The use of such substances can be particularly aggressive to some materials, dependent upon the frequency of use and concentration of the active material. For example, VHP in high concentration can affect some paint finishes and formaldehyde can have an adverse effect on aluminium. A further consideration is the negative pressure environment required within a containment facility. To maintain effective containment, some areas may be subjected to pressure differentials of around 60 Pa or more. This type of pressure could have an adverse effect on some types of construction, particularly walls and ceilings. Doors also need to be carefully considered, so that they cope with the required pressure regimes and the resultant air flow between rooms with such high differential pressures. Simple things on how doors open and close can be easily forgotten and have a major impact on the operation of facility if not considered during the early phase of the design. Often the finishes used have been developed and produced specifically for these sorts of environments. The requirement does differ between categories of laboratory. For example, a CL2 facility requires only bench surfaces to be resistant to acids, alkalis, solvents, disinfectants, impervious to water and easy to clean. However, in CL3 facilities, the floor surface must have the same criteria. Laboratory bench worktops made from varnished timber (potentially obtained from sustainable sources) could also meet the above criteria. However, they would require regular maintenance to maintain their integrity. Typically, either solid plastic laminate such as Trespa® or solid resin worktops are used. Depending on the nature of substances used and activities carried out within the laboratory, bench tops or other work surfaces could be formed from other materials such as stainless steel, ceramics, lead or glass. The colour of the worktop material may also be critical, so that if particular hazardous materials, for example liquid or powder form, are accidently spilt, then they can be easily seen and the appropriate clean-up processes be undertaken quickly and safely.
24.5.3 Other specialist requirements Some facilities have very particular requirements that have a specific bearing on the design of the facility, in terms of planning, materials to be used and the mechanical systems to be installed. For example, when there is the requirement to accommodate live animals, often in either clean environments or containment facilities, or where animal disease control and vaccine development are being studied, detailed legislation published to cover such facilities must be adhered to. In the UK, the Department for Environment, Food and Rural Affairs
© Woodhead Publishing Limited, 2010
604
Materials for energy efficiency and thermal comfort in buildings
(Defra)17 categorise animal pathogens and the required conditions of containment through the Importation of Animal Pathogens Order 1980 (IAPO), as amended and the Specified Animal Pathogens Order 2008 (SAPO). However, it should be noted that these differ from those published by the Advisory Committee on Dangerous Pathogens (ACDP). ACDP is concerned with protection of workers in the workplace, whereas Defra is concerned with livestock and the environment. Notwithstanding the basic requirements for cleanliness or containment and depending on the type of facility being considered, the fact that animals are to be accommodated will often have an additional bearing on the choice and use of materials and details used in the construction of these rooms. Urine and other waste products, for example, can have a detrimental effect on some materials, and the size or species of the animal can also present particular challenges. Depending on which species, smaller sized animals are usually kept in cages or tanks, housing either individual or larger numbers of specimens.18 Cages range from the simple open style type, located directly on the floor of the room, to sophisticated caging systems, often stacked or grouped together, to enclosed cage systems where the internal environment of each individual cage is carefully controlled and monitored. These are often referred to as individually ventilated cages, or IVCs. Medium sized animals such as chickens, can present different problems. If they are free to roam within the rooms, they can quickly and easily damage room finishes through pecking walls or floors, particularly at joints. Therefore a finish that resists such damage should be considered. Larger animals, such as cattle for example, whether contained or again free to roam within the room, are capable of damaging normal, relatively substantial construction materials such as concrete block walls and plaster. Their hoofs can quickly damage sheet flooring such as vinyl and other similar floor finishes. Such rooms may well be constructed using reinforced concrete for the walls (with a high performance paint finish) and epoxy or similar screed floor laid to falls to assist with resistance to damage, as well as washing down and waste removal. Slip resistance of floor materials should also be considered where hoofed animals are being housed. In buildings where there are animals, it is also good practice to construct the building in such a way that cavities and voids within the construction are avoided and all elements are sealed. This will reduce the risk of unwanted infestation, such as insects, mice, etc., that could compromise the bio-security of the facility. The choice of materials used for either the structure or finishes of such rooms are critical. The right choice will ultimately reduce the amount of potential damage that could be caused. If the right materials are chosen and the right details used, then potential repair or replacement works are reduced
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
605
leading to less facility shut downs. Additional cost and energy (in carrying out the repairs as well as manufacturing replacement materials, their transport, etc.) is also reduced, thus improving in a number of ways the efficiency of the facility.
24.5.4 Mechanical systems considerations There are many reasons for the provision of specialist environments. Due to the specific nature of some of these facilities, the overriding requirement must be to conform to, and achieve, regulatory compliance. However, to do so often requires systems or solutions that use relatively high levels of energy to operate in a safe, controllable and predictable manner. Whilst the compliance requirements of each classification of clean room environment are well documented, the manner in which they are to be achieved is documented in much less detail. It is generally accepted that pharmaceutical facilities operating under ISO 8 (Class 100 000 under the superseded US STD 209E) can achieve regulatory compliance with air change rates of 10 to 15 per hour and the appropriate level of supply air filtration. However, for pharmaceutical facilities operating under ISO 7 and ISO 5 (Class 10 000 and Class 100 under the superseded US STD 209E) air change rates of 25 per hour and above coupled with the requisite grade of HEPA (high efficiency particulate air) filtration on both the main supply air handling units and on room terminal discharge units would generally be provided. The micro-electronics industry often utilises significantly higher air change rates than these and employs ULPA (ultra low particulate air) filtration levels to achieve their requirements. HEPA and ULPA filters are not only expensive to purchase but also expensive to install and validate. Tests must be carried out to ensure that no leakage is allowed to bypass the filters and once in place it is desirable to leave them to operate for long periods of time before changing them. The reasons for this are not only the costs of replacement but also the requirement to ‘break’ the sterile or particulate barrier by removing the filter units. This removal often requires the complete room or facility to undergo a deep cleaning exercise to restore the required level of sterility or particulate cleanliness, and in higher specification rooms this may take several days to achieve. In order to avoid the need to change these units they are designed to handle high pressure differentials between their clean and dirty states, often as high as 600 Pa to 700 Pa. The high air volumes required by such facilities coupled with the high resistance to airflow through the HEPA and ULPA filters means that the electrical energy used to power the air conditioning system is very high. This can be minimised by selecting high efficiency fans and equipment but the need to consume significant amounts of energy in conditioning the supply air still exists. It should be realised
© Woodhead Publishing Limited, 2010
606
Materials for energy efficiency and thermal comfort in buildings
that in these instances it is the cleanliness classification of the environment which dictates the amount of energy consumed by requiring such large air volumes and high filter resistances rather than the heat either gained or lost by way of equipment operation or through the building’s external fabric. In such facilities, whilst compliance with the thermal requirements of the Building Regulations19,20 must be achieved, the enhancement of the building’s insulation values beyond this level would not significantly reduce the amount of energy consumed by the air conditioning systems. In containment facilities the extract systems are often the ones that require high levels of filtration in order to prevent any substances contained within the facility from being discharged to the atmosphere. Other process facilities may not have a particulate problem in their discharge systems but may need to eradicate fumes, vapours or odours. This could be achieved with various forms of filtration including devices such as activated charcoal filters or liquid based fume scrubbers21 all of which have a high resistance to air flow. Any such extract system consumes high levels of energy due to the resistances of the filtration methods used (Fig. 24.6). In a micro-electronic facility it is often a requirement to minimise the challenge on the ULPA filters by re-circulating as much of the extract air as possible. This means that the amount of ‘dirty’ outside air is limited to the minimum amount required to provide comfort conditions for the people working within the area, whilst the ‘clean’ extract air that has already passed
24.6 Installation of complex extract and supply ductwork above a clean room environment.
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
607
through the ULPA filters is recirculated to avoid unnecessary clogging of the filters, thus extending their working life. This recirculation contributes largely to the reduction in energy consumption under certain external conditions but it does not allow for the use of ‘free cooling’ when a favourable enthalpy balance occurs between the external air and the required internal conditions. However, this recirculation facility can only be achieved in areas which have no process contamination in the extract air. In a pharmaceutical facility, whilst the desire to minimise the challenge on the HEPA filters is strong, the desire to reduce the challenge of crosscontamination is often stronger and this is achieved by using a ‘once through’ air supply and extract system. This means that, whilst ‘free cooling’ would be used to reduce energy consumption when a favourable enthalpy balance occurred between the external air and the required internal conditions, only an indirect form of heat recovery such as a recuperator or run-round coil installation could be used in place of direct recirculation and this again reduces the energy recovery available. In addition to the sterility or cleanliness of the process areas, there is often a requirement for particular internal environmental conditions to be maintained. This can be driven either by the particular process requirements or by the need to maintain reasonable levels of comfort whilst personnel are working within an area. When using a compound that is hygroscopic, it may be necessary to maintain a very dry atmosphere to ensure product quality, extended shelf-life or provide suitable flow characteristics to allow packaging to take place. This requirement for low humidity can be as little as 10% or 20% rh. In order to achieve such low humidity levels, we once again have to consume energy in a seemingly inefficient manner. This process could involve over-cooling the supply air in order to force out any moisture contained in the fresh air only to have to reheat it again to maintain a suitable internal temperature within the facility. Lower humidity levels often require the use of chemical dehumidification which avoids the need for over-cooling of the supply air. However, this process uses high heat levels to regenerate the dehumidifier and drive off the unwanted moisture which in turn requires the supply air to be cooled to a more suitable room supply temperature once again using large amounts of energy. The same process requirement often requires the internal room temperatures to be maintained at a lower than normal level. In a sterile facility the personnel are gowned in specialist clothing which prevents them from shedding particles into the room whilst they are working. This type of clothing prevents the body from cooling in a normal way and as such the internal room temperatures may need to be maintained as low as 16 °C or 18 °C in order for the operatives to feel more comfortable and avoid the need for constant breaks. All of the above require the provision of large quantities of ‘black’ utility
© Woodhead Publishing Limited, 2010
608
Materials for energy efficiency and thermal comfort in buildings
supplies such as chilled water, low pressure hot water heating, steam and condensate and many more to support the process environmental condition. But there are many more process or ‘clean’ utilities that are often required for use in the process itself such as various grades of purified water, clean steam, breathing grade compressed air and so on. All of these must be produced to strict regulatory requirements and they need to consume a lot of energy to achieve this. Many such high performance facilities need to have their conditions of operation maintained 24 hours a day and 7 days a week. It would not be possible to turn off the supply and extract air systems to a highly sterile environment at 6 o’clock in the evening and to turn it all back on at 7 o’clock in the morning expecting to achieve adequate sterile conditions again. The maintenance of sterility often includes a suitably cascaded pressure regime which would be lost if the air systems were switched off or reduced. This means that some of the more frequently used methods to conserve the use of energy, such as setting back the supply and extract air volumes or switching off air supplies altogether during unoccupied periods, are not available to these facilities. The setting back or relaxation of temperature or humidity levels may sometimes be acceptable but this is often dependent on the sensitive electronic equipment requirements within the process area and could only be identified on a case-by-case basis. Another issue raised by the need to maintain conditions at all times in such facilities is that the energy supplies used to power the air conditioning systems must also be very dependable. This means that the use of renewable energy sources such as wind powered turbines or systems with seasonal variances in output could only be used to supplement the standard utility supplies. As the standard utility supplies will need to be installed in sufficient capacity to meet 100% of the demand, the additional cost of providing a partial contribution from renewable sources when measured against their contribution to the overall energy consumption of a facility may render them uneconomic in many instances. Recognising the fact that utility supplies can and do fail, many such facilities have dual fuel systems coupled with twin electricity sources and generator back-up installations to ensure a true 100% energy availability. One type of facility that often needs to combine both process environment and people areas in the same space is a research laboratory. This type of space needs to have a process type environment containing fume cupboards,22 medical gases, solvents and other substances which are at best ‘smelly’ and at worst ‘extremely harmful’, but also needs to have an aesthetic aspect which allows stimulation of the scientists, often with views to the outside world. These areas will use larger air volumes to provide the necessary fume cupboard containment but the air volumes and as such the energy usage can be reduced by selecting low volume fume cupboards wherever the processes permit. These, coupled with the use of variable air volume supply and extract
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
609
air systems where several fume cupboards are located in one laboratory, can all contribute towards the reduction in supply and extract air volumes and hence reduce energy consumption (Fig. 24.7).
24.5.5 Electrical systems considerations By the nature of their function, high performance facilities demand far more power than buildings in other sectors. Additionally the quality of the power supplied needs to be clean and continuous. Breaks in supply due to utility switching operations or external faults can result in loss of valuable research and production. It is therefore common to reinforce the supply with incomers from different utility sources and then to supplement these with standby generation or local uninterruptible power supply systems. A high voltage supply would normally comprise an SF6 or vacuum-based switchgear which has proved to be a safer alternative to the older generation oil-filled switchgear. These are suitable for indoor or outdoor locations.
24.7 Typical laboratory fume cupboard arrangement with adjacent benching.
© Woodhead Publishing Limited, 2010
610
Materials for energy efficiency and thermal comfort in buildings
To convert the high voltage to low voltage, non-flammable liquid-filled or cast resin transformers are the preferred choice for indoor locations, while conventional oil-filled units are the economical choice for installation externally. With oil-filled equipment there is the inherent risk of fire and if sited internally would require substantial fire resistant construction as well as suitable fire suppression systems. The low voltage distribution would generally comprise cubicle-type fully enclosed switch panels with fused switches or circuit breakers for outgoing circuits. Meters would be provided on most circuits to enable accurate monitoring of energy consumption. Standby sources would comprise diesel fuelled generators that would tie in to the distribution system. High performance facilities usually rely on sensitive instrumentation and robots for some of their core research activities. These usually require a clean uninterruptible power supply usually sourced from local or central battery backed UPS systems. The arrangement of the power distribution system needs to address continuity of supply during routine maintenance activities and this can be achieved by selection of appropriate switching arrangements. The energy consumed by high performance facilities can be considerable and it is not uncommon for them to have a demand of between 200–350 W/m². Most of this goes into providing power for the ventilation and cooling systems. It is therefore important to select drive combinations that are not over-sized, utilise high efficiency motors, inverter drives and which are supported by correctly implemented control systems. Fume cupboards are commonly used in research facilities. There have been advances in their design to enable robust containment using a lower velocity of air flow. In addition, occupancy sensors can be utilised to further reduce air flow with a reduction in energy consumed. Lighting installations consume a much lower proportion of the energy used. Nevertheless, the use of luminaries with high efficiency lamps, high frequency dimmable control gear and optical controllers which allow high light transmission do help to reduce the overall lighting load. The control of lighting by occupancy sensors with daylight sensing further improves efficiency. More sophisticated automatic lighting control systems are normally used only where a specific pattern of lighting is required, e.g. in veterinary facilities which could also incorporate ‘red’ lighting to allow staff activity to continue during simulated periods of darkness. The trend in emergency lighting is to use light emitting diode (LED) fittings which require less power and smaller battery and control equipment. The power source for emergency lighting can be either central or distributed. Central systems have the advantage that battery replacement can be done locally in the non-sensitive plantroom areas, but do require an initial higher capital cost in wiring distribution.
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
611
Internally in the research areas of such facilities, the primary consideration in the selection of luminaries, sockets, perimeter trunking and other accessories is that of containment and cleanability. Where exclusion to all non-research or production staff is required, items of equipment such as luminaries are installed such that all routine maintenance can be carried out from above or outside the space. To further reduce access by maintenance staff, automatic testing systems are specified to facilitate periodic testing of emergency lighting without the need to enter the facility. With the availability of DALI control gear for luminaries it is possible to remotely monitor the operational status of individual light fittings as well as identify any lamp failures. This can be a valuable maintenance tool. Services penetrations to sensitive rooms need to be sealed either by use of an inert non-hardening compound or by proprietary modular sealing systems. Luminaries that are recessed can achieve a seal by virtue of their construction. Equipment is also installed such that it is flush with the walls or ceilings to aid in cleaning and to prevent ‘ledges’ and grooves that can become dust traps. For communication systems there is a greater trend towards use of wireless and hands-free equipment in research areas. This minimises the need to touch equipment and therefore control cross-contamination. In certain research establishments there is a greater need to collect and process data electronically. This demands a greater density of category 6 structured cabling and data outlets over the benches. There is a slow trend towards higher speed category 7 systems.23 There is also a requirement for local area networks within facilities for building management systems used for the control and monitoring of the environmental conditions, and for more onerous controls and monitoring an Environmental Management Systems is used, in particular where the activity is validated. These networks are also then connected to wide area networks to facilitate rapid and efficient sharing and processing of information. For emergency fire alarm and evacuation systems, care needs to be taken in these facilities to prevent false alarms or deliberate actions from creating security breaches and to cause unnecessary shut down of ventilation plant. In some facilities the correct choice for the tone of the alarm sounders could be important due to occupancy and types of research being conducted within the facility. The location of the sounder is also important as they have to be housed out of the area or they have to be enclosed in a ‘clean’ enclosure which will mean that the devices have to be increased to comply with the regulations.24 Security systems are a necessity for high performance facilities. Breaches can lead to loss of activity, theft of controlled substances, damage to property and equipment and possible release of potentially dangerous contaminants. Deterrents to intruders include secure fencing/walls, high security doors and windows. Detection includes electronic intruder detection and access
© Woodhead Publishing Limited, 2010
612
Materials for energy efficiency and thermal comfort in buildings
control systems which are in turn linked to sophisticated CCTV surveillance systems. In order to ensure business continuity of high performance facilities it is vital that a robust maintenance regime is set in place that will include strategies to optimise operating costs, enhance reliability, meet compliance requirements, and extend the useful life of assets.
24.6
People areas
It has been identified that specialist environments, such as process facilities, often need to consume energy without much in the way of compromise. However, the supporting areas around the core processes do give opportunities for the use of more ecologically friendly installations. Areas such as offices, canteens, storage, goods-in and out, meeting rooms, welfare facilities, break-out spaces, libraries, etc., can employ systems which are more suited to minimising energy consumption and promote the use of sustainable or renewable energy sources. These areas can be treated independently from the core process areas but it should be recognised that areas which are naturally ventilated should be adequately separated from areas which have pressure regimes as part of their regulatory compliance requirements. The effect of wind on a building, especially parts of a building which are naturally ventilated, can cause substantial pressure changes within the facility. If a core process area is being measured against an adjacent area which is subject to unpredictable pressure changes, this can put the whole pressure regime at risk and cause serious operational problems.
24.7
Environmental design and computer modelling
The requirement for compliance with current Building Regulations still applies to buildings containing specialist environments, including the Part L2 requirements for carbon emissions.25 In order both to identify the requirements of Part L2 and to prove compliance, it is helpful to use certain modelling techniques, and proprietary software is usually used to assist in this design process. This software can be used to perform many different functions during the design process including heating and cooling load analysis, shading analysis, annual energy usage, plant/system sizing and Building Regulation compliance checks. Compliance with Part L2 of the building regulations can be checked in several ways. These include the use of approved commercially available proprietary thermal modelling software, which utilises the National Calculation Method (NCM), or by using the SBEM (Simplified Building Energy Model).
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
613
Using these techniques we can identify the anticipated normal building carbon emissions for a given class or type of building against which to measure both the designed and actual building carbon emissions. When using thermal modelling software in the design process, it is important to distinguish between the data output achieved when carrying out Building Regulations Part L2 compliance checks and using the package as a design tool to develop the building design and associated plant selection. When carrying out Part L2 analysis the software ignores much of the data the user inputs to create the model used for detailed thermal analysis such as occupancy times, air change rates, internal gains, etc. When applying the NCM templates used for the Part L2 analysis, the software uses the same information for both the actual and the notional building based on the template selected from the available database. Therefore, many of the variables are fixed, resulting in a ‘like-for-like’ comparison of the building performance between the notional building based on 2002 regulations and the actual building under consideration designed to 2006 regulations. Whilst there are many NCM templates available for selection when defining the building type or room function these still tend to be limited in their extent for industrial and process applications. hence it is difficult, if not impossible, to select a template that closely matches the criteria for a building of this nature. In these cases it has often been agreed with the regulatory authority that ‘process areas’ be omitted from the model when carrying out the Part L2 analysis since the input data and the subsequent results bear little or no resemblance to the reality. This should be avoided wherever possible since the figures in the resulting EPC (Energy Performance Certificate) produced when the building is completed will be similarly distorted. It should be remembered however, that no matter how accurately the data in the NCM template matches the building output data, this data should not be used as a design tool as it does not represent the actual building. One aspect of the current building regulations that has benefited the process building is the requirement for a suitably airtight facility. The requirement which is primarily aimed at reducing energy costs caused by infiltration can assist in achieving stable pressure regimes within a process facility. The requirement to comply with airtightness testing has resulted in many manufacturers of external shell components such as cladding, window walling, roofing, etc., to improve the jointing details of their products in order to assist in achieving suitable airtightness, but in many cases this also assists in the stabilising of internal pressure regimes.
24.8
Environmental and energy considerations
There are many opportunities with the design of any building to include within its design provision for either reducing the energy consumption of the building
© Woodhead Publishing Limited, 2010
614
Materials for energy efficiency and thermal comfort in buildings
and its processes and/or the integration of alternative energy technologies and sustainability measures, some of which have been discussed earlier. With buildings designed to accommodate specialist environments, the integration of energy saving measures or alternative technologies can only be considered if their introduction does not compromise the ability of the specialist environments to function correctly and, very importantly, safely. As with all such issues, the impact of cost will always be a governing factor, such as the initial prime cost for installing such technologies, life cycle costs including maintenance/renewals, and the ‘payback’ time required to recover any additional costs spent associated with the integration of ‘green’ technologies. It is true that opportunities exist to incorporate relatively cheap or even cost neutral energy saving design into a building, but it is equally true that some potential energy saving elements are at the moment at least relatively expensive. All clients, users, buildings and the facilities they contain are different, and therefore what is feasible with regard to incorporation of energy efficiency and sustainability into any particular design will always need careful consideration early in the design process. Experience in the pharmaceutical industry, and knowledge of the specialist requirements for such facilities and their environments, has lead to the development of strategies for assessing the benefits or not of incorporating environmentally aware and/or energy reducing opportunities into such buildings, whilst taking into account the specialist nature of the facility and the specific energy requirements. In doing this, a system consisting of Category A, B, C or D has been developed for assessing the opportunities available in relation to the specific requirements of the building or facility being designed as follows: ∑
Category A: What would be considered as a routine part of their detail design (ideally with 0–5 year payback) ∑ Category B: What would involve a reasonable amount of expenditure but would assist in improving the credentials from the environmental aspects of the building (usually with a 5–10 year payback) ∑ Category C: What would not be recommended due to cost, practicalities, high maintenance and extended payback period (usually 15 years+ payback) ∑ Category D: Not suitable or applicable to this project. As stated above, each building is unique and the specialist environments it contains will have specific and critical requirements. However, below are the sort of issues one would consider appropriate to review at the commencement of each project, and a brief commentary on the suitability of each. This list is not exhaustive, and the criteria or threshold for acceptance in any given situation will vary between projects:
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
615
Solar heating Solar heating is often a good way to reduce the cost of providing hot water to a building but its effectiveness relies on a number of factors. In some instances, such as laboratories, the requirement for hot water would need to be split into two separate systems. This is to ensure that the system feeding the laboratories cannot in any way contaminate the system used for other purposes. Whilst a single solar heating system could be used to feed both systems, the load required, compared to what could be produced using this method, would need to be assessed. Solar heating installations fare much better where there is a regular demand for hot water throughout the year. Laboratories are generally of low occupancy, and demand for hot water could be such that the payback period for a solar heating system would be greater than normally expected (in excess of 10–15 years) and therefore could be considered not to be a cost effective option. Rainwater harvesting (use of grey water) The harvesting of rainwater is a useful option where there are a large number of low grade water requirements such as large toilet blocks or irrigation of the landscape. Some buildings could have very limited use of low grade water if utilities and the landscaping is of a reduced size and is being designed for low water consumption. Rainwater is not suitable for use in laboratory type environments, where the quality of the water supply is often very important. Rainwater harvesting is therefore not normally a cost effective option for small or mid-sized buildings. Ground source heat pumps The use of low grade energy as supplied by a ground source heat pump installation is suitable for low energy use buildings. The installation would typically require sinking 30 m to 60 m boreholes (dependent on the ground conditions) or laying flexible pipework (slinkies) in a large shallow excavation, typically under a car park or similar tarmac covered area. Whilst the ‘slinky’ type installation is more cost effective, the loads achieved by this type of installation are less than the more expensive borehole option. Many specialist environments use high levels of energy, and therefore, if ground source heat pumps were to be considered, they would only realistically supply a small proportion of the energy required. The payback period for this type of system is typically in excess of 10 to 15 years and hence is not normally considered a cost effective option for specialist environments.
© Woodhead Publishing Limited, 2010
616
Materials for energy efficiency and thermal comfort in buildings
Water course/heat sink The use of a local water course as a heat sink has been used many times but this is dependent on the permission of the local water authority. They will have strict guidelines as to the amount of any discharge that can be made, the effect of the downstream water temperature and many other limiting factors. This solution requires similar considerations concerning the amount of energy produced compared to the amount of energy required. Also, having a suitable water course at a convenient location to the building is not very common. Combined heat and power (CHP) The use of a combined heat and power installation is usually reserved for a building or group of buildings which have a large and equally balanced energy demand. Individual, small or medium sized buildings do not usually warrant the installation of a CHP system but it may be a future consideration for the site as a whole. Natural ventilation As discussed previously, the use of natural ventilation is generally not suitable for specialist environments. The conditions within need to be controlled to meet a number of criteria such as temperature, humidity, containment, make-up air (to exhaust equipment such as fume cupboards) and pressure differentials. Natural ventilation can, however, be used in people areas such as offices, although if there is a risk of insect or other infestation, then appropriate measures to prevent this affecting the specialist environments would need to be incorporated. Depending on the extent of natural ventilation incorporated, the size of the air handling plant could be reduced in size. Wind turbines The use of wind turbines usually requires a large area on which to site the turbines and a clear air path with good wind conditions. Sites are often restricted in size and adjacent topography would need to be suitable (i.e. site not located in a depressed area, in close proximity of adjacent tall features such as other buildings, embankments, etc.) in order not to disrupt air paths. Other issues may be noise of the turbines both in the facility itself, and to adjacent properties, particularly if residential. The wind turbine, perhaps more than any other alternative energy source, has visibility issues and would be very dependent on the view of the local planners and nearby residents. The energy requirements of a building containing specialist environments are usually constant, and the variable supply of energy from such a wind
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
617
driven device would also require a permanent supply to be installed as well as the turbine option. Natural light Accommodation such as offices and meeting rooms, located on the perimeter of buildings, will benefit from natural light. Depending on orientation, the amount of light (and solar gain which could be an issue) would vary. Other factors that could influence this are shading or shielding from adjacent tall structures, such as other buildings or trees. Some specialist environments, such as laboratories or manufacturing areas if located on the perimeter of the building, could be subjected to problems due to the varying intensity of light levels thus obtained. In these sorts of environments, sensitive equipment could be adversely affected by bright or changing light levels. In laboratory buildings, for example, a common solution in dealing with the issue of natural light is to locate the laboratory areas in the middle of the building, with the office and ‘write-up’ areas between the laboratory and the external perimeter wall. This allows the non-critical office areas to benefit from natural light, whilst the laboratory areas utilise artificial lighting to provide a uniform and constant lighting environment. If a glass wall is used between the laboratory and the office or ‘write-up’ area, then the scientists within the laboratory benefit from direct views to the outside, thus overcoming some of the disadvantages of being located within the centre of the building. It should be noted that there are many instances where the internal environment requirements allow laboratories and other specialist environments to be located on the external wall of a building, thus benefiting from direct natural light. Although depending on orientation, there may be the need to incorporate windows with adjustable shading as appropriate. However, in these instances, additional mechanical cooling may be required to overcome heat gains through the effects of solar gain. because of the environmental conditions required within, specialist environments often need relatively large plant room areas. Here there is the opportunity to incorporate substantial amounts of glazing to potentially benefit from natural light, thus reducing the reliance on artificial lighting. However, the need for good light levels, particularly for certain maintenance activities, indicates that too much reliance on natural light is not particularly suitable for this part of the building. Heat gains reduced by orientation of the building Depending on the usage of the building, it is sometimes appropriate to allow ‘controlled’ build-up of solar gain within areas that have the greatest heating demand, thus reducing the amount of energy required to heat the building.
© Woodhead Publishing Limited, 2010
618
Materials for energy efficiency and thermal comfort in buildings
This, however, has to be weighed against the need to provide cooling in the event of excessive solar gain and heat build-up. Some buildings, by the nature of the activities undertaken within them, produce high levels of heat and thus require a high proportion of induced cooling, and this is typical of many specialist environments. In these instances it is often appropriate to reduce the amount of solar gain thereby reducing the amount of cooling required. Some specialist environments such as laboratory areas contain large amounts of heat emitting equipment (fridges, freezers, incubators, water baths, PCs, etc.) and will therefore require cooling for most, if not all, of the time they are in operation (which can be 24 hours a day, 7 days a week). Thus additional heat build-up within the building through, for example, solar gain should therefore be avoided. For a new building, careful orientation to reduce the extent of unwanted solar gain should be considered. For windows in areas where solar gain should be avoided, they should generally be north, east or west facing, thus benefitting from natural light, but shielded from the extremes of unwanted solar gain. In these instances, critical accommodation should not be on the south facing elevations, or if it is, the south elevation should ideally be without windows. In these instances, other non-critical accommodation could be located consisting of storage areas, offices, break-out areas, etc., thus acting as a shielding buffer to the effects of excessive heat build-up to the sensitive, specialist environments. It is not always possible to orientate the building to suit ideal conditions, and there are other factors that could dictate orientation such as aspect, adjacent properties, approaches to the building, site shape, planning constraints, plans for future development, etc. Passive infra red (PIR) based motion detector/switching to artificial lighting systems PIRs are often used to control (and reduce) the amount of artificial lighting used in areas such as break out spaces, toilets, locker rooms, stores, corridors and staging areas (i.e. they will turn the lights on when they detect movement, and turn the lights off after a period of time when no movement is detected). PIRs help to overcome the waste of energy when lights are left on in unoccupied areas. However, they are not suitable for use in most specialist environments, in laboratories for example, as they can be a safety hazard. Daylight compensation lighting In areas benefiting from natural lighting it is often appropriate to incorporate a dimming system controlled by a photocell to reduce the output of the lights depending on the intensity of the daylight at any given time. This
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
619
has the effect that, when natural daylight levels increase, the intensity of the artificial lighting decreases, and vice versa, thus saving on energy used by the lighting system. Building Management System (BMS) controls For specialist environments, the environment and the equipment that provides it can be controlled by an electronic Building Management System (BMS). This would be capable of providing time clock control of systems, night setback for out-of-hours periods and many other energy saving functions. Not all of the functions available will be suited to any particular facility or building and those that could be used would be the subject of a discussion with the users, the maintenance staff and the design team during the detailed design of the facility. Roof lights and light pipes (or tubular skylights) Roof lights are a recognised way of admitting natural light into areas of a building that are away from the external walls. The types of buildings specialist environments are housed within are often typically two floors or more in height, with the relatively large plant space located over the specialist environments to optimise services distribution. This therefore restricts considerably where roof lights could be incorporated. Roof lights themselves, whilst admitting natural light, are problematic when used in specialist environments. They are often dirty and not easy to keep clean, thus are a maintenance issue. They have a potential for leaking and because they are usually glass, there is an increased risk of breakage as well as condensation build-up. Light pipes are becoming more common and are a way of bringing natural light into the interior of a building at locations well away from the external wall. However, these rely on running the pipe through the roof covering of the building which means that, like roof lights, they penetrate through the insulation and outer weathering layers. Due to the sensitivity of some buildings’ usage, and the requirement to therefore minimise penetrations through the roof and reduce the risk of future water leaks and sealing problems, these types of device are not normally used in specialist environments. Photovoltaic cells It is widely recognised within the industry that the use of photovoltaic elements cannot normally be considered in terms of cost payback alone as the high cost of installation compared to the energy returns received is not yet economical. Payback period is still considered and could even be in the
© Woodhead Publishing Limited, 2010
620
Materials for energy efficiency and thermal comfort in buildings
region of 100 years. The use of photovoltaic elements could also radically change the physical appearance and construction of the facility, although some industrial roof sheeting products have now incorporated a flexible photovoltaic (PV) laminate onto their sheeting and some PV cell manufacturers have created a range of individual (but interlinked) cells that can be incorporated within a traditional concrete or clay roof tiling system. The above represent only some of the considerations relating to alternative energy sources and energy reducing opportunities that could be included within the design of a new specialist environment facility. The following are a few further considerations with respect to the potential for using sustainable materials or sustainable methods of construction. External cladding Timber cladding from managed sustainable sources and the use of ‘green roofs and walls’ has been discussed earlier as well as the implications these could have on the building and the specialist environment it contains. With the more traditional industrial cladding systems used over the past 50 years, such as steel, aluminium and glass, the drive for the reduction in the use of limited raw materials in building construction is now beginning to have an effect, for example the amount of recycled aluminium and ancillary materials such as mineral wool insulation and glass that is now used within the industry has been increasing over the past few years. Curtain walling and cladding manufacturers are actively trying to increase this figure; however, the issue they are struggling with is that, whilst this reduces the reliance on using additional raw materials and hence reducing the reliance on unsustainable mining by incorporating recycled materials, the energy involved to recycle the old or wasted material can also be significant. One of the main benefits of using a system-based cladding system (whether it is an aluminium, steel or timber system) is that it can be partially prefabricated and factory assembled thus minimising the installation process and reduces to a minimum the amount of waste produced. This form of construction also reduces the risk of forming critical installation and junction details which can now be undertaken within factory conditions. This process has a number of benefits such as quickening the site installation time, improving insulation and thermal details, reducing waste and reducing the potential for safety associated risks on site. Flooring The choice of the correct floor finish is critical to the success of any specialist facility, and this is particularly so within pharmaceutical environments.
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
621
Factors that are taken into consideration when specifying a floor finish are: durability, aesthetics, cost and environmental considerations. In a pharmaceutical or laboratory environment, the main criterion has to be durability. It must be able to withstand potential spillages and impact whilst maintaining a safe surface on which to walk. Floors to laboratories are usually sealed to prevent any spillages seeping through the floor (sheet materials are joint welded) and the finish is coved to form a bunded skirting against walls. Any weakness within the floor finish could compromise safety and increase the risk of contamination. There are many different types of flooring that could be used, depending on the areas within which the floor is to be laid. Epoxy resin or polyurethane screed flooring systems of various specifications and thicknesses are sometimes used, as are high performance paints laid directly on the concrete floor slab or screed. However, the predominant type of flooring used is a sheet material flooring system. There are two main sheet flooring types commonly used, either vinyl or linoleum. As already mentioned, the main factor to be considered is durability. Vinyl is considered to be the better of the two floor sheet materials for critical pharmaceutical and laboratory environments. Although linoleum could be used, it can be more susceptible to damage from impact or heavy loads being wheeled over it and has generally less resistance to chemical spillages, thus resulting in maintenance costs increasing due to the potential for more frequent replacement or repair. From a manufacturing perspective, the difference between vinyl and linoleum is that vinyl is made from PVC derivatives whilst linoleum is made from naturally occurring renewable materials such as linseed oil. It could therefore be appropriate to consider vinyl sheeting for critical areas and linoleum sheet flooring for all other areas requiring a sheet flooring type finish, but without the requirements of a more durable material. Carpets and particularly carpet tiles are usually considered for office and meeting room areas. The opportunity exists to use products currently on the market that are made from a high percentage of recycled materials. Typically certain carpet ranges consist of 70–80% of recycled material and, where an underlay is required, these could be made from up to 100% recycled material. Paint systems These days there are many water-based paint systems available that overcome the environmental and safety issues associated with solvent-based paints. However, for some applications, particularly where durability or performance is required, solvent-based systems are still used.
© Woodhead Publishing Limited, 2010
622
Materials for energy efficiency and thermal comfort in buildings
Similar choices are available for other building products and systems, such as ceilings, doors and partitions. As noted previously, for specialist environments, whilst the requirement for a facility which is highly energy efficient and utilises renewable energy and sustainable materials is a desirable aim, the building will have specific functions to perform. If the performance of those functions is compromised or indeed if the necessary regulatory requirements for any such functions cannot be met, then the building becomes effectively useless.
24.9
Building research establishment environmental assessment method (BREEAM®)
In the UK, the BRE Trust26 Companies provide independent research, consultancy and testing advice for the UK’s built environment industries on a wide range of topics, including: ∑
Environment: creating sustainable indoor and outdoor buildings, infrastructure and transport environments that are comfortable, productive, safe and healthy. Also energy efficiency in buildings – providing techniques and technologies for the effective management of energy and the integration of new and renewable energy systems in buildings. ∑ Construction: working at the forefront of engineering, materials science and process management to provide solutions for all aspects of construction from design to end of life, and strategic issues – such as risk management and corporate social responsibility. ∑ Fire and risk in the built environment: delivering world-class solutions for fire safety. To provide guidance and create improving targets for energy efficiency building design and construction, the BRE Trust Companies have developed the BREEAM (Building Research Establishment Environmental Assessment Method) which is now the leading and most widely used environmental assessment method for buildings, with over 115 000 buildings certified and nearly 700 000 registered. It sets the standard for best practice in sustainable design and has become the de facto measure used to describe a building’s environmental performance. Credits are awarded in ten categories according to performance. These credits are then added together to produce a single overall score on a scale of pass, good, very good, excellent and outstanding. The operation of BREEAM is overseen by an independent Sustainability Board, representing a wide cross section of construction industry stakeholders. Aims of BREEAM ∑
To mitigate the impacts of buildings on the environment.
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
623
∑
To enable buildings to be recognised according to their environmental benefits. ∑ To provide a credible, environmental label for buildings. ∑ To stimulate demand for sustainable buildings. Objectives of BREEAM ∑
To provide market recognition for low environmental impact buildings. ∑ To ensure best environmental practice is incorporated in buildings. ∑ To set criteria and standards surpassing those required by regulations and challenge the market to provide innovative solutions that minimise the environmental impact of buildings. ∑ To raise the awareness of owners, occupants, designers and operatives of the benefits of buildings with a reduced impact on the environment. ∑ To allow organisations to demonstrate progress towards corporate environmental objectives.
24.10 Future trends The ever increasing demands of the multitude of regulatory authorities and the ever tightening requirements of the Building Regulations, coupled with rising energy prices, creates more and more pressure on companies to reduce energy consumption and source what energy they do use from sustainable or renewable sources. The continued development and improvement in all building sectors and in particular those requiring specialist facilities will help to reduce some of the energy consumption issues that currently affect these types of facilities. In chemical and biological research industries, for example, improved techniques will mean that less and less volumes of agents and compounds will be required to be catered for within specialist environments for research purposes. In turn, the ever more demanding requirement for sterility in pharmaceutical production may appear to require yet more energy to meet with ever onerous regulatory compliance. There are, however, many ways in which reductions in the high energy use of specialist environments can be made. One such development is the increased use of isolators to provide a contained micro-environment in which a process is carried out without the need to condition a whole room. This can reduce air and filtration loads and hence reduce energy consumption. A further advance is the increased use of robots in research and production for certain repetitive tasks. These robots can often operate without shedding the same amount of materials as would occur with human intervention and can work for extended lengths of time, effectively making better use of the necessity to maintain conditions in the facility 24 hours per day. Within the
© Woodhead Publishing Limited, 2010
624
Materials for energy efficiency and thermal comfort in buildings
pharmaceutical sector the future trend for using robots is on the increase and is evolving rapidly, for example, within large sample stores, assay development, compound and similar storage areas. The following is just an example of how robotic use is developing. It is essential that within the pharmaceutical industry, compound inventory is accurate and that compounds are stored in appropriate, and often specialist conditions to reduce as much as possible the degradation of the compounds over a storage period of anything up to ten years as liquid stocks. A mediumsized sample store, for example, could consist of a single robot that runs on a central track. This robot is capable of the storage/retrieval of compound plates as well as ‘cherry picking’ a defined list of compounds out of the store (custom sets). The amount of water and the number of freeze thaw cycles can affect the quality of compounds stored as liquids, as compounds are generally solubilised in 100% DMSO (dimethyl sulfoxide). The advantage of this type of storage facility over previous facilities is that it can supply single use compound samples to the high throughput screening (HTS) group in a format that is ready to test. This minimises the number of freeze thaw cycles and minimises the potential of water uptake into the compounds. This type of store offers greater flexibility over other more conventional storage systems as the robot can place compounds in any position defined by the end-user for testing. The system also uses 20% of the amount of compound that the previous storage systems required. The type of building stores, and their robotic operations, now use localised controlled environments, thus reducing the costly and energy hungry facilities that would be required if humans were still undertaking the tasks which robots can now perform (Fig. 24.8). Over the coming years compound storage and collection is likely to increase considerably. At present large sample stores (LSS) are being constructed and these new stores offer the same benefits containing up to four robots running on two tracks and offer over five times the capacity of the previous medium storage system and four times the throughput. The future is now moving from a single robot to multiple robots running on multiple tracks which will offer far greater capacity and throughput compared with previous systems installed only (say) three years ago. Other examples within the pharmaceutical sector, where automation can be incorporated together with complex service requirements, can be found in the use of robotic technology in the high resolution rate replicator pods used for the preparation of source plates. Here, the plate replicator pods are fully enclosed and under positive pressure. A dedicated air handling unit is connected through a duct to the top of the enclosure allowing dry air to be forced out through filters. Automation in screening and pharmacology and its integration into the research environment is also designed to maximise throughput by automating
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
625
24.8 Typical UHTS robotic compound store by REMP.
previously manual experiments. Installation of automated equipment can change the way that a company can carry out day-to-day work, e.g. throughput is higher and many of the once laborious manual steps have now been automated. Before the installation of this equipment, high throughput screening was run using less flexible, less intuitive systems and only a very small number of trained individuals could run it. In contrast, new technology has allowed many of the scientists who were previously not using automation to become comfortable running experiments in an automated manner. Automation has allowed facilities to become smaller and skilled staff to spend more of their time doing research. In summary, new robotic systems such as the new ultra-high throughput screening (uHTS) systems can help improve the research and production process, through providing not only increased throughput, but additional benefits of more compact and efficient buildings, reduced time scales and reduced staff costs. The above examples demonstrate the changing requirements of energy capacity, human occupancy and specialist conditions required in just one small sector of one industry. Requirements through all sectors and industries are now far more demanding than in the past and, with it, the challenges and opportunities to control the amounts of energy and materials required – this is not the end of the line for energy, efficiency and selective use of the earth’s resources, but just the beginning!
© Woodhead Publishing Limited, 2010
626
Materials for energy efficiency and thermal comfort in buildings
24.11 Sources of further information and advice ∑
ACDP (Advisory Committee on Dangerous Pathogens) ‘The management, design and operation of microbiological containment laboratories’. ∑ BRE – The Building Research Establishment (BRE) BREEAM reference manuals for various building types 2008. ∑ MHRA (Medicines and Healthcare products Regulatory Agency) ‘Rules and Guidance for Pharmaceutical Manufacturers and Distributors 2007)’.
24.12 Notes and references 1 Validation is the process of checking whether something satisfies a certain criterion. FDA Guidelines 1987 define validation as ‘Establishing documented evidence which provides a high degree of assurance that a specific process will consistently produce a product meeting predetermined specifications and quality attributes’. Qualification and Validation of pharmaceutical facilities is required to ensure that the facility complies with strict guidelines for drug manufacture. In the UK, guidelines are provided by The Medicines and Healthcare products Regulatory Agency (MHRA) http://www. mhra.gov.uk/index.htm and in the United States by the Food and Drug Administration (FDA) http://www.fda.gov/. New facilities are assessed (or qualified) through four elements and involve the compilation of a Validation Master Plan (VMP) document that records all Validation activities and their planning. A written protocol should be established that specifies how Qualification and Validation will be conducted. The stages and requirements of Qualification Validation are explained in detail in the ‘Rules and Guidance for Pharmaceutical Manufacturers and Distributors 2007’, compiled by the MHRA. In it, the four elements of Qualification are described as: ∑ The first element of the validation of new facilities, systems or equipment could be Design Qualification (DQ). ∑ The second element relates to Installation Qualification (IQ) which should be performed on new or modified facilities, systems and equipment. ∑ Operational Qualification (OQ) should follow Installation Qualification (IQ). ∑ Performance Qualification (PQ) should follow successful completion of Installation Qualification (IQ) and Operational Qualification (OQ). 2 The British Pharmacopoeia (BP), now published annually, is a comprehensive collection of standards for UK medicinal substances.
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
627
The Medicines and Healthcare products Regulatory Agency (MHRA) launched the new British Pharmacopoeia (BP) website, www. pharmacopoeia.gov.uk. MHRA describe the British Pharmacopoeia (BP) as: ‘it contributes to the overall control of the quality of medicinal products by providing an authoritative statement of the standard that a product is expected to meet at any time during its period of use. The publicly available and legally enforceable pharmacopoeia standards are designed to complement and assist the MHRA licensing processes for medicinal products, and are part of the system for safeguarding public health. The BP is an essential reference for all individuals and organisations involved in pharmaceutical research, development, and manufacture and testing of medicines’. 3 The Medicines and Healthcare products Regulatory Agency (MHRA) define good manufacturing practice (GMP) as: ‘that part of quality assurance which ensures that medicinal products are consistently produced and controlled to the quality standards appropriate to their intended use and as required by the marketing authorisation (MA) or product specification. GMP is concerned with both production and quality control’. Further information can be found on the MHRA website at: http://www.mhra.gov.uk/Howweregulate/Medicines/ Inspectionandstandards/GoodManufacturingPractice/index.htm 4 The Medicines and Healthcare products Regulatory Agency (MHRA) define good laboratory practice (GLP) as: ‘a set of principles that provides a framework within which laboratory studies are planned, performed, monitored, recorded, reported and archived. These studies are undertaken to generate data by which the hazards and risks to users, consumers and third parties, including the environment, can be assessed for pharmaceuticals, agrochemicals, veterinary medicines, industrial chemicals, cosmetics, food and feed additives and biocides. GLP helps assure regulatory authorities that the data submitted are a true reflection of the results obtained during the study and can therefore be relied upon when making risk/safety assessments’. Further information can be found on the MHRA website at: http://www.mhra.gov.uk/Howweregulate/ Medicines/Inspectionandstandards/GoodLaboratoryPractice/index. htm 5 Further information on life cycle costing (LCC) including best practice guidance and case studies can be found at http://www.ogc.gov.uk/ implementing_plans_introduction_life_cycle_costing_.asp. 6 A drug which is produced and distributed without patent protection is termed a generic drug. In most cases, generic products are available once the patent protections afforded to the original developer have expired (typically a patent could last for 7–12 years). When generic products become available, the market competition often leads to substantially
© Woodhead Publishing Limited, 2010
628
7 8
9 10 11
12 13
14
Materials for energy efficiency and thermal comfort in buildings
lower prices for both the original brand name product and the generic forms. The two general classes of combustion are deflagration and detonation: ∑ Deflagration is defined as subsonic combustion that usually propagates through thermal conductivity (most fires). ∑ Detonation is defined as combustion in which a supersonic shock wave is propagated through a fluid due to an energy release in a reaction zone. It is generally more powerful than deflagration. MHRA guidelines are covered in the ‘Rules and Guidance for Pharmaceutical Manufacturers and Distributors 2007’, also known as the ‘Orange Guide’. Further information can be found on the MHRA website: http://www.mhra.gov.uk/index.htm Further information can be found on the FDA website: http://www. fda.gov/ EN ISO 14644-1:1999 – Amendment No 1 – March 2001. Good Manufacturing Practice (GMP) – Commission Directive 2003/94/ EC of 8 October 2003 laying down the principles and guidelines of good manufacturing practice in respect of medicinal products for human use and investigational medicinal products for human use. Good Manufacturing Practice (GMP) – Commission Directive 91/412/ EEC of 23 July 1991 laying down the principles and guidelines of good manufacturing practice for veterinary medicinal products. An isolator is basically a sealed enclosure where the operator is outside and can manipulate processes or undertake activities within the isolator through gloves or half suits that are built into the external fabric of the enclosure. BS EN ISO 14644 (Part 7) provides guidance on the design, placement, testing and maintenance of separate clean room devices (such as isolators). The isolator is designed primarily to give a very high level of protection to the operator (or product). The device provides assured protection in varying levels by utilising physical or dynamic barriers, or both, to create separation between operation and operator. They may contain special atmospheres, which could include either negative or positive internal pressure conditions. Other specialist containment devices offering differing degrees of protection include: laminar flow enclosures, microbiological safety cabinets and fume cupboards. Traditionally, pallets are constructed from wood framework and slats. Wood is prone to damage and shedding particulates into the atmosphere. Wood also harbours bacteria and does not meet the cleanliness requirements of modern pharmaceutical environments. GMP pallets, specifically designed to meet the requirements of good manufacturing practice, are usually constructed of non-shedding and easily cleaned materials such as plastic or aluminium. © Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
629
15 ‘The management, design and operation of microbiological containment laboratories’ by the Advisory Committee on Dangerous Pathogens (ACDP). 16 ‘Biosafety in Microbiological and Biomedical Laboratories’, 5th Edition, 2007, published by the US Department of Health and Human Services – Centres for Disease Control and Prevention and national Institutes of Health (www.cdc.gov). 17 Defra (the Department for Environment, Food and Rural Affairs) is a government department in the UK. The overarching challenge for Defra is to secure a healthy environment in which we and future generations can prosper – http://www.defra.gov.uk/. 18 The health and welfare of animals are carefully regulated in the UK by Defra. For example, laboratories required to meet Defra containment requirements are licensed under the Specified Animal Pathogens Order (SAPO). 19 Building Regulations 2000 for England and Wales – Approved documents A to P. Published by the Office of the Deputy Prime Minister (now known as the Department for Communities and Local Government (DCLG)). 20 Building (Scotland) Regulations – Published by The Scottish Building Standards Agency, since re-integrated into the Scottish government and has become part of a new directorate for the Built Environment which includes Planning and Architectural Policy. It is now known as Scottish Building Standards (SBS). 21 Fume scrubbers can take several forms but all achieve a similar function. These devices utilise a liquid, typically water, to wash or scrub the exhaust air being drawn from a room or piece of equipment before discharging it to the atmosphere. These devices can range from items which are similar to fume cupboards but have a cascade or ‘waterfall’ effect through which the extract air is drawn, to more industrial devices which pull the extract air through one or more water baths to ensure maximum contact with the water and the highest levels of capture of any substances within the exhaust air. These devices are used where airborne substances cannot be effectively filtered out by using a dry process and substances in a vapour or aerosol format are typical examples. In some more industrial applications the substance removed from the exhaust air may have a residual value which makes its recovery from the scrubbing solution an economically viable proposition. 22 A fume cupboard is basically a ventilated enclosure where the operator is outside and can manipulate experiments or undertake activities within the fume cupboard through openings in the front face of the enclosure.BS EN 14175 (Parts 1–6) provide guidance on the installation, placement, testing and maintenance of fume cupboards. The fume cupboard is
© Woodhead Publishing Limited, 2010
630
Materials for energy efficiency and thermal comfort in buildings
designed primarily to give a certain level of protection to the operator. The enclosure is designed to limit the spread of airborne contaminants to operators and other persons outside the device; it offers a degree of mechanical protection and provides for the controlled release of airborne contaminants. Other specialist containment devices offering differing degrees of protection include: laminar flow enclosures, microbiological safety cabinets and isolators. 23 In the UK, data cabling is covered by various standards which include: ISO/IEC IS 11801, TIA/EIA 568B and EN 50173-1. (ISO/IEC IS 11801 is a global standard that has evolved to meet the needs of all geographic areas.) These documents refer to various cabling categories. These are described as Category 1 through to Category 7 cabling. 24 In the UK there are a number of regulations or codes of practice relating to the design and installation of electrical installations in buildings. For specialist facilities, these include: (a) BS 7671:2008 – The IEE Wiring Regulations (b) ISPE (The International Society for Pharmaceutical Engineering) Good Practice Guides. (c) CIBSE (The Chartered Institution of Building Services Engineers) Guides and Application Notes. 25 Building Regulations 2000 for England and Wales – Part L deals with conservation of fuel and power. There are 4 parts: ∑ Approved Document L1A – Conservation of fuel and power in new dwellings (2006 edition). ∑ Approved Document L1B – Conservation of fuel and power in existing dwellings (2006 edition). ∑ Approved Document L2A – Conservation of fuel and power in new buildings other than dwellings (2006 edition). ∑ Approved Document L2B – Conservation of fuel and power in existing buildings other than dwellings (2006 edition). Further details regarding the Building Regulations which are applicable to England, Ireland and Wales can be found at: http://www.direct. gov.uk/en/HomeAndCommunity/Planning/BuildingRegulations/index. htm 26 BRE – The Building Research Establishment (BRE) Trust Companies are owned by the BRE Trust, a registered charity with a mission to champion excellence and innovation in the built environment. Further information can be found at www.bre.co.uk. For further information on the design and construction of specialist facilities for high performance industries, the reader is invited to contact Prakash Davda at The Austin Company of the UK Ltd: Tel: +44 (0)1923 432 658. Email:
[email protected] or
[email protected] www.austin.co.uk
© Woodhead Publishing Limited, 2010
25
Materials for energy efficiency and thermal comfort in new buildings
L. S h a o, De Montfort University, UK
Abstract: New buildings in the UK need to achieve zero carbon emissions by 2016 (dwellings) or 2019 (non-dwellings) but there are numerous challenges. This chapter highlights two of the major challenges facing the new build construction sector, namely, delivering real carbon savings as intended in the design, and balancing carbon reduction with adaptation to the future climate. These will be illustrated in discussions about a number of material technologies and presented in the context of current and future legislation. Key words: new build, real performance, adaptation to climate change, thermal mass, vegetation.
25.1
Introduction
It is estimated that the new buildings constructed between now and 2050 could account for one-third of the total building stock in 2050 in the UK (Glass et al., 2008). Although their volume is smaller than that of the existing buildings, they are highly significant not least because they are best placed to achieve the best levels of carbon reduction performance, and help set the standard for all buildings. The difficulty is enormous though. The government has set the target for all new dwellings to achieve zero carbon emissions by 2016 and all new non-dwellings to achieve the same by 2019. The protracted and complicated discussion about the definitions of zero-carbon has revealed the tip of the iceberg of the challenges, which are diverse and dynamic. The following discussion is not meant to be comprehensive, which is beyond the scope of this chapter. It will instead highlight some current and acute challenges facing the new build construction sector, e.g., genuinely delivering carbon savings at levels as originally intended in the design, and balancing carbon reduction with adaptation to the future climate. These will be illustrated with discussions about a number of sustainable material technologies in new buildings – thermal mass, PCM, and vegetation and high albedo building surfaces. Some of the other important issues, such as glazing, will not be one of the foci as they have been covered more extensively elsewhere. The current and future legislations will also be discussed as will the interdependency among future climate, buildings and lifestyles. 631 © Woodhead Publishing Limited, 2010
632
25.2
Materials for energy efficiency and thermal comfort in buildings
Challenges facing the new build construction sector
25.2.1 Design and reality A glaring issue often associated with the new buildings, particularly those which caught the headlines with innovative energy technologies they incorporated, is their failure to deliver real performance as originally intended in the designs (Usable Buildings Trust: http://www.usablebuildings. co.uk). This threatens to harm the very cause the projects were supposed to promote – a phenomenon which has triggered the creation of terms such as ‘Green wash’. The PROBE series of post occupancy evaluations and the work of the Usable Buildings Trust, inter alia, have established major contributing factors for the lower than expected performances in reality. They are found in the design process, during commissioning, after handover and in facility management. In this chapter, the discussion will be directed towards some other factors – the better understanding of technologies themselves, their real performances in new buildings and effect of greater insight on designs that deliver better results. An example of investigations in such an area is presented by Wingfield et al. (2007). based on extensive monitoring and measurement in a new build residential project, they showed that whole house heat losses were higher, sometimes by over 100%, than predicted. The work led to the discovery of thermal bypass at the party wall as a major contributing factor. This chapter will present further materials under the theme of real performances of sustainable technologies. The reliable delivery of real performances will be facilitated by a more outcome orientated approach, placing more emphasis on the performance than the non-technical appeals of specific technologies, more emphasis on hard numbers than on qualitative trends, more emphasis on real buildings test results than on modelling, more emphasis on repeatable performances than on one-off peak values, more emphasis on independent data than on manufacturers’ claims, and more emphasis on integration and interaction in real installations than on isolated component performances. Also valuable to the real-performance cause would be a culture of giving preference to robust technologies; in-depth understanding, as opposed to box-ticking; joined-up thinking, e.g. in considering both winter and summer requirements when adopting a material; and a true and detailed understanding of the activities and energy profiles in the building. There is insufficient real performance data available. The reasons include a lack of routine practice of post-occupancy evaluation (POE), a lack of rigourous demonstration/research projects, and insufficient coordination of efforts, for example in the adoption of common protocols for monitoring and publishing building performances. The often encountered difficulty in
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
633
accessing existing data is a further barrier, and mechanisms are needed to encourage and reward its removal.
25.2.2 Balancing mitigation with adaptation One of the major threats to the sustainability of recently completed new buildings is their inadequate capacity to adapt to future climate change. While Building Regulations are tightening in terms of reduction of carbon emissions, and new buildings are becoming more energy efficient, the same Regulations make limited requirements on buildings to prevent overheating under future climate conditions. In fact, many new buildings, e.g. new flats such as those shown in Fig. 25.1 and new schools, are affected by overheating even under the current climatic conditions. The Code for Sustainable Homes set stringent performance requirements in nine categories but did not go
25.1 Many new builds are at risk of overheating in summer even under the current UK climate.
© Woodhead Publishing Limited, 2010
634
Materials for energy efficiency and thermal comfort in buildings
much beyond the current Building Regulations in terms of preventing future overheating of the tightly built new houses. The London Climate Change Adaptation Strategy (Greater London Authority, 2008) explained that the urban heat island intensity (UHI) reached up to 10 K in the city during the deadly heat wave of 2003. The impact of climate change is increasingly felt through more frequent occurrence of extreme weather events such as heatwaves. The UKCIP (www.ukcip.org. uk) predicted that the extreme temperatures experienced in London could increase by 10K by 2080. If this is combined with the UHI of 10 K, which has already occurred, the adaptation challenge will be severe. There is an urgent need to build sufficient adaptation capacity in the new buildings as they are likely to experience the full impact of future climates. Among the many issues involved, which include flooding, storms and high winds, we will focus more on heatwave adaptation because it is more closely linked to the energy issue. Legislation and voluntary codes should be updated to give greater emphasis on delivering higher standards in overheating prevention. Building designers and owners should take this onboard immediately. Higher adaptation performances of buildings are fundamentally beneficial to their ability to mitigate climate change. Buildings which are effective only in carbon emission reduction will not survive for long and so ultimately will not be successful. An issue relating to the prevention of building overheating is the alleviation of the UHI effect. Although this is beyond the scope of this chapter, it suffices to say that many of the passive measures for reducing building overheating are likely to have a positive effect on the UHI too (Greater London Authority, 2008).
25.3
The role, shape and trend of legislation
The building energy related legislation is playing a crucial role in driving up the carbon and energy performances of new buildings. Energy and carbon prices are not high enough, yet, to become a major driver of the change. The wide awareness of climate change has not been translated into actions of similar magnitude. A study published in 2008 for NHBC by the research organisation EPR found that energy efficiency was not a major factor in the purchase of a new home. A better kitchen or bathroom has a higher priority in the minds of potential buyers. Although the majority of the UK population are taking some form of action to reduce energy use, including using compact fluorescent lamps to replace GLS versions, turning off lights and recycling domestic waste, much less is being done to major areas of energy consumption such as heating. Legislation will remain as a main driving force in the near future. So far a key piece of legislation has been the EU Energy Performance
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
635
of Buildings Directive (EPBD), adopted in 2003. This was implemented in the UK in 2006. In England and Wales, this was in the form of the 2006 revision to Part L of the Building Regulations and the Energy Performance of Buildings (Certificates and Inspections) Regulations. The revisions to Part L were set out in four Approved Documents published in April 2006. Two of these relate to new builds – L1A and L2A, for new dwellings and new non-domestic buildings, respectively. The 2006 Approved documents stipulate that carbon emissions of new buildings must be lower than a calculated target value, that specific building components must exceed threshold performance levels and that the building must not overheat without active cooling. The requirements and assessment procedures for overheating prevention differ for dwellings and non-dwellings, allowing a range of possible tests, including those based on solar gains, overheating periods or building design/use details. The standards of construction, commissioning and provision of information to the building owners are also covered. Energy and carbon emission calculations were based on Standard Assessment Procedure (SAP) and SBEM (Simplified Building Energy Model) or DSM (Dynamic Simulation Model) for dwellings and non-domestic buildings, respectively. Compared with the 2002 Regulations, the 2006 Regulations represent carbon reductions of 20% for domestic buildings. Similarly, the reduction for non-domestic, non-air-conditioned buildings is 23.5% and for non-domestic air-conditioned buildings, 28% (CIBSE, 2008). The 2006 Approved Documents represent significant advances but it is an interim step in a programme of rapidly evolving legislation. Certain areas of the regulations are underdeveloped, e.g., assessment of overheating in new dwellings using SAP Appendix P could be significantly upgraded by setting more stringent requirements. The many aspects of oversimplification, e.g. in building use profile, weather, ventilation and thermal dynamic processes, could also be improved. The overheating assessment of non-domestic buildings is also affected by similar problems, though to a lesser extent at this time. In addition, the overheating criteria should be examined and updated to more accurately reflect the severity and impact of overheating (CREW: http://www. extreme-weather-impacts.net/twiki/bin/view), and take into account the future climate patterns. Given numerous reported incidents of overheating in domestic and non-domestic new builds, even under the relatively cooler current climate, this aspect of the building regulations should receive greater attention. The implementation of the EPBD also resulted in the Energy Performance of Building (Certificates and Inspections) Regulations 2007, which requires an Energy Performance Certificate (EPC) for all buildings when built, sold or rented. Furthermore, it requires a Display Energy Certificate (DEC) for all public buildings larger than 1000 m2 and regular inspection of air conditioning systems with cooling capacities larger than 12 kW.
© Woodhead Publishing Limited, 2010
636
Materials for energy efficiency and thermal comfort in buildings
In 2007, the CLG issued a policy statement (CLG, 2007) confirming the government’s plan for new homes to be zero carbon by 2016 and new nondomestic buildings to be zero carbon by 2019. The CLG outlined a staged implementation of the policy – further enhancement of Building Regulations in 2010 is expected to reduce new build carbon emission by 25% compared with the 2006 Approved Documents and the Building Regulations revised in 2013 and 2016 would result in 44% carbon emission reduction and zero carbon emission from new dwellings, respectively. Note that zero carbon represents over 100% reduction because the 2006 Approved Documents only regulate certain categories of energy use (water and space heating, lighting but not appliances, cooking and cooling). A zero carbon dwelling would require about 150% carbon emission reduction from a level represented by the 2006 Approved Documents (NHBC Foundation, 2009). Closely related to the zero carbon homes agenda is the Code for Sustainable Homes (CLG, 2008b), which is an energy and environment rating system for new domestic buildings. Among the nine categories of sustainable design issues is energy use and carbon emissions of the dwelling. Homes achieving the best level of the Code, Level 6 will have achieved zero carbon emissions, while those at Level 5 will have achieved 100% reduction compared with the 2006 Approved Documents. The reductions for levels 1 to 4 are 10%, 18%, 25% and 44%, respectively. At the time of writing the definition for zero carbon in new homes was going through a consultation process initiated by the CLG (2008a). As shown in Fig. 25.2, the proposed definition of zero carbon involves not only carbon emission levels but three separate factors – energy efficiency (e.g., the insulation standards of the building fabric), carbon emission levels and allowable solutions which may include approved investment and export of
Allowable solutions
Carbon compliance
Energy efficiency
III
II
I
25.2 The structure of a zero carbon dwelling definition, which reflects the serious difficulty in eliminating carbon emissions.
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
637
renewable heat. The complex system could allow a new home which emits carbon dioxide to be labelled zero carbon. The situation, although controversial and confusing, does serve to highlight the enormous practical difficulty of achieving zero carbon through technical means alone. Substantial lifestyle change, which reduces demand and facilitates implementation of renewable technologies at various scales, would be necessary. The power of legislation and regulations is reflected in the Merton Rule – local planning requirement that 10% or more of the energy supply of a new building should be from on-site renewables. The regulation has been exceptionally effective in promoting a range of energy technologies, including the Ground Source Heat Pump, which is more expensive than higher levels of insulation and other more basic technical interventions. While invaluable for promoting the implementation of renewables, it does point to a need for more integrated policies and legislation that will enable balanced approaches to carbon emission reduction that maximise carbon performances. In November 2008 the UK adopted the Climate Change Bill which set a legally binding target of at least an 80% cut in greenhouse gas emissions by 2050, against a 1990 baseline (DECC: http://www.decc.gov.uk/en/content/ cms/legislation/en/content/cms/legistation/cc_act_08/cc_act_08.aspx). Against this backdrop, the tightening of carbon emission requirements in the building regulations is set to continue, although their impact will be dependent on a multitude of factors, not least a culture of delivering real performances. Crucially, there should be stringent requirements for the new builds to adapt to the future climate, particularly the heatwaves and other extreme weather events. Embodied energies in new buildings, and life cycle energy use are also important factors to consider in future building energy legislation.
25.4
Thermal mass
This section illustrates some of the key challenges for new builds by focusing on a significant material-related issue – thermal mass. This is a particularly appropriate issue for the new build sector as adding substantial thermal mass in the renovation of existing homes would be more difficult. There are two principal applications of the thermal mass. The first is to use it as a form of thermal storage for passive solar or other thermal gains. For dwellings, the heat stored during sunny daylight hours, for example, is released during the occupied hours at night, thereby reducing or removing the need for space heating. In the second type of application, the thermal mass absorbs the heat during the day in summer, thus reducing the peak temperature and improving thermal comfort. The higher thermal mass will result in smaller temperature fluctuations between night and day and also a phase shift of the daily temperature cycle, both of which could be utilised
© Woodhead Publishing Limited, 2010
638
Materials for energy efficiency and thermal comfort in buildings
through appropriate design to bring about a cooler indoor environment during hot weather. As explained in Section 25.2.1, the real performance could be quite different from predictions. It was reported by Tuohy et al. (2004) that several tests involving high- and low-mass houses showed that higher mass resulted in more heating energy consumption. The CIBSE Guide F (2004) also stated that high-mass buildings which are intermittently heated (as opposed to continuously heated) tend to consume more heating energy than low-mass ones adopting the same heating patterns. On the other hand, a Concrete Centre report (2006) quoted energy savings of up to 11% for masonry and concrete dwellings compared with lightweight counterparts, based on several computational studies commissioned by the concrete industry in 2005/6. Quoting further research commissioned by the concrete industry, the report stated that a typical two-bed semi-detached house in South-East England could save carbon emission of about 150–350 kg p.a. on average over the 21st century. A piece of work which helped resolve the conflicting claims was that by Tuohy et al. (2004), who carried out a well constructed programme of simulation based on two simple and similar buildings which they referred to as (Brenda and Robert) Vales Rooms, which featured low and high thermal masses. The low-mass building contained only lightweight elements e.g., plasterboards, within the insulation envelope while the high mass building was constructed primarily from concrete within the same insulations. The research showed that higher thermal mass could result in less, similar or more heating energy consumption depending on three levels of insulation. Energy savings improve with insulation levels. The higher heating energy consumption at a lower level of insulation is a result of a larger amount of heat required to heat up the building fabric which subsequently leaked out to the environment. The work further revealed that higher thermal mass is more likely to save energy when used in the warmer southern climate of the UK than in the North and when there is a high continuous occupancy. Combining northern climate, weekend occupancy only, and lower insulation level could mean that the high-mass building consumes 50% more energy for heating. The impact of infiltration/ventilation rate is similar to that of the insulation level – higher mass buildings tend to perform better when the building is more airtight. This piece of research revealed that higher mass is not directly linked to energy savings and that the insulation and infiltration standards of the construction may significantly sway the relative attractiveness of highmass building over lower mass ones. The relative success of the high-mass Hockerton housing development is a testimony to this principle: All houses were super insulated and meticulous attention was paid to minimising thermal bridge and infiltration. As insulation and infiltration levels are important factors, the standard of construction is therefore crucial. The multitude of
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
639
influencing factors also means that it would be necessary to simulate each new building individually during the design process to determine the best level of mass – there is no fixed rule in this regard. A significant conclusion regarding thermal mass of new buildings is that under the current building regulations, the energy consumption of a new building is unlikely to be substantially influenced by the level of thermal mass. Indeed, the Passive House standard does not specify a thermal mass requirement. In contrast to the variable winter energy saving performances, the effect of high thermal mass on reducing summer overheating is more significant. Givoni (1998) reported his measurements on two houses in Southern California with identical U-values but significantly different levels of thermal mass (0.5≤ plasterboard vs 10 cm concrete inside external insulation, for the low- and high-mass buildings, respectively). The higher mass building achieved up to 3 K reduction of peak indoor air temperature, which is further reduced by about 1.5 K when night time ventilation between 7pm and 7am was implemented. The simulation work by Tuohy et al. (2004), based on buildings of similar contrast of high and low thermal mass levels, indicated similar levels of temperature reductions for the high-mass building. The impact of night time ventilation is affected by local climate, being less effective for certain parts of the southern European countries around the Mediterranean. It is also influenced by how the ventilation air flows across the room, by the room surface covering and the presence and utilisation of hollow-core structure elements such as the TermoDeck panels. It is certain, though, that night time cooling works better with higher mass buildings (Tuohy et al., 2004). As with many other technologies, the high thermal mass design could introduce conflicting design requirements for winter heating and summer cooling – and require ‘joined-up’ thinking. Winter heating is often optimised by utilising passive solar design, which feature certain elements like sun spaces with large glazing areas which are not always easily openable. The best effect of high mass for summer cooling is achieved with night time ventilation, which is often not facilitated by the glazed sunspaces. Fortunately the choice would not be too difficult to make. For high-mass design the priority should be placed on passive cooling considerations, as this is the area where the benefit is significant, consistently achievable and where we meet some of the most significant challenges imposed by climate change on future buildings. The sunspaces will gradually become much less used. The evidence comes from both technical analysis and comparative observation. If the climate of Britain is to become more like that of the Mediterranean region, the shape of building there now can serve as a useful indicator of buildings of Britain in the future, although not literally. The choice of design should be based on detailed modelling and
© Woodhead Publishing Limited, 2010
640
Materials for energy efficiency and thermal comfort in buildings
analysis using the appropriate weather and occupancy/activity patterns, rather than copying. The challenge of climate change is unprecedented, particularly in terms of extreme weather events such as heatwaves. In this sense, what the UK could experience in the future may be quite different from what has been happening around the Mediterranean. An exception to using high thermal mass in buildings for passive cooling is the stilt houses found in hot and humid climates such as in Thailand or Malaysia (see Fig. 26.3 (a) and (b)). Here the buildings not only have low mass themselves, but are also deliberately decoupled from the thermal mass of the ground. Although high mass will bring a reduction of peak indoor temperatures it will, on the other hand, raise the minimum temperature as heat absorbed during the day is released. The stilt houses, containing very low thermal mass, ensure cool room temperatures at night, creating the optimum conditions for restful sleeping. In contrast, high mass and wellshaded colonial buildings in tropical regions work better during the day, as borne out by thermal comfort studies in these regions (Sanusi, 2006). A variation of the high-mass design is the earth labyrinth, which makes use of the large mass of the ground and the stored coolness there. Compared with conventional thermal mass, it is switchable although the radiative and conductive benefits of high-mass elements in the living space are not available. In operation it is more like an earth-air heat exchanger so will not be discussed further here. An insightful review of this topic is provided by Pfafferott et al. (2007).
25.5
Phase change materials (PCMs)
A further variation of the high-mass design is to implement phase change material (PCM) components in the building. As the scope of the discussion is construction materials rather than mechanical systems, the following discussion will be confined to building components containing PCM, particularly PCM wallboards. Although the mass of the PCM itself is not high, the substantial latent heat involved in the phase change process enables the PCM components to absorb/release heat as if it has a much higher thermal mass. As such, one would expect that performance characteristics of thermal mass, e.g., insignificant winter energy savings, would hold true for PCM components. This is true but only to a certain extent. The low impact of PCM on heating energy savings is confirmed by recent research, as reported by BASF AG (2006). It was found that the incorporation of PCM plasterboard (melting range: 21–25 °C, 26% PCM by weight) in lightweight buildings had little impact on the heating load. The effect on cooling load is greater but the impact on carbon emissions is significant only if the use of installed air conditioning is minimised. The BASF study is well
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
641
(a)
(b)
25.3 The high-mass Queens Building (Leicester) is effective in reducing peak temperatures in summer (a). This is in contrast to the low-mass building on stilts which decouple the house from the mass of the ground. It is effective in ensuring minimum night temperatures (b).
© Woodhead Publishing Limited, 2010
642
Materials for energy efficiency and thermal comfort in buildings
organised and detailed though based on computer modelling. The thermal conduction and heat storage in the PCM plasterboard were calculated using the dynamic building simulation program DYNBIL from the Passiv Haus Institut. Good quality experimental results were available from a study carried out at the Fraunhofer Institute (Schossiga et al., 2005) in two full-sized test rooms in the Fraunhofer façade test building. Two identical well-insulated low-mass rooms were fitted with PCM (40% by weight) and conventional plasterboards, respectively. The PCM has a melting range of 24–27 °C. During a three-day monitoring period, the rooms were subjected to night time ventilation but were not shaded. Air temperatures in both rooms started off with identical values but diverged once they reached 26 °C. The peak air temperature in the PCM room was over 3 K lower than the conventional room but even on the first day the PCM was fully discharged before the temperature peaked. Even with night time ventilation, the PCM did not get fully charged so during the following day the temperature reduction dropped to just over 2 K and this narrowed to less than 1 K on the third day. The results showed the crucial importance of allowing PCM to fully recharge and matching the PCM capacity with the cooling load thus preventing complete PCM discharge. These were achieved by providing shading to both rooms and the results showed sustained temperature reduction over a seven-day test period, though the level of peak temperature reduction was reduced to less than 2 K as the PCM plasterboards were not stretched to full capacity. It was also clear that the PCM plasterboard had limited effect for room temperatures below 26 °C and it is more effective for reducing temperatures above 28 °C as the PCM would be more active. During a 20-day test period the conventional room was warmer than 28 °C for 50 hours, compared with 5 hours for the PCM room. These, of course, would change with internal gains and other factors in an occupied building. The need for appropriate design is again highlighted by the results of another set of tests on full-sized rooms fitted with PCM and conventional plasterboards (Feng et al., 2005). The melting range was 19–22 °C. These would be very comfortable temperatures if the indoor temperature could be held close to this range. However, even the night time outdoor temperature rarely dropped below 22 °C during the test period so the PCM was not able to charge at all. Consequently, the air temperature in the PCM room is practically identical to that in the reference room (PCM room is 0.2 K lower on average). The above highlights a practical design issue with PCM – unlike conventional thermal mass which would moderate temperature oscillations at all temperatures, the PCM does so only within a limited temperature band, centering on its melting range. Beyond this range, it will not function. Put
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
643
in somewhat oversimplified words, a building considered to be high-mass because of its PCM components will be high mass only within a limited range of temperatures, beyond which it will behave as a low-mass building. In addition, the conventional thermal mass will function the same way regardless of the magnitude of the heat load it is subjected to. The PCM, however, has an upper limit imposed by its latent heat capacity, beyond which a PCM ‘high-mass’ building will again behave as one of low mass. In this context, PCM plasterboard intended for mitigating overheating of buildings in summer should have melting temperatures set close to the upper threshold of thermal comfort as the above test results have indicated. Setting lower melting temperatures could result in more days of very comfortable temperatures but no effect on the uncomfortable hot days. In mixed mode spaces, however, the melting range should be lower than the AC set point and the recharge should be by night time free cooling. In terms of balancing the requirements for winter heating and summer cooling, it is very difficult to reconcile the need for passive solar design in winter and passive cooling in summer if PCM is the common element of thermal storage for both, because the required melting ranges would be well apart from each other. One solution might be to implement interchangeable PCM panels but the quantity required present significant practical difficulties. The range and capacity limitations of the PCM is particularly significant for dealing with exceptional heatwaves, when its design melting range could be well below the extreme temperatures and the design capacity of the PCM component could be overwhelmed, resulting in a low-mass shell that offers little thermal protection against the high temperatures. This is compounded by higher night temperatures which make recharging difficult, particularly during still, windless nights. The conventional thermal mass is superior in terms of the issues outlined above. However, our discussion has been limited to the construction’s components without considering wider PCM-based devices. Furthermore, the issues of construction cost and maintenance have not been discussed either.
25.6
Vegetation and reflective materials
It is very likely that reflective materials and vegetation will be utilised more widely in the future because of their potential for reducing building overheating, preventing or minimising the use of air conditioning, and also mitigating the UHI. In this chapter, however, our focus is on building-related applications including reflective roofs, green roofs and green walls. The structural, drainage, safety and other requirements of the green roof suggest that it is more easily implemented in a new build. Although there have been many years’ research on their performances based on computer
© Woodhead Publishing Limited, 2010
644
Materials for energy efficiency and thermal comfort in buildings
modelling, the availability of good quality data obtained from tests on real buildings is limited. Tests carried out in Greece by Niachou et al. (2001) showed that the green roof installed on an insulated ceiling brought about reductions of room air temperature of 0.5–2.0 K, averaging about 1 K over the three test periods. The period when the indoor temperature was over 30 was reduced 70% to 15% in one of the monitoring periods. The tests were carried out when the buildings were not occupied so that the air conditioning could be switched off to remove its effect on indoor temperature results. Switching to modelling, the study showed that the total energy saving including those from both heating and cooling seasons would be insignificant at 2% if the roof supporting the vegetation is well insulated (e.g., 10 cm insulation sandwiched between 10 cm concrete elements). This saving would be dramatically increased to 37% if the roof is uninsulated (e.g. bare 10 cm concrete). However, in the context of new builds, this is rather improbable. A further test programme in Greece measured the effectiveness of green walls (Eumorfopoulou and Kontoleon, 2009). A six-storey building was used and the external surfaces of the lower three storeys were covered with climbing plants (Parthenocissus triscuspidata) to an average thickness of 25 cm. A room on the second floor and another on the third, on the east facing façade were used in the study. Comparison of the temperatures taken on the external and internal surfaces of the rooms showed that the vegetation reduced the external surface peak temperature by up to 6 K, averaged over the month-long test period. The peak temperature of the internal room surface was reduced by 0.9 K. Although the shading and evaporation provided by the leaves of the plants may help to reduce the roof external surface temperature and help to alleviate indoor overheating (as well as UHI if widely adopted), the same process may be detrimental to winter energy efficiency of the building. An alternative to vegetation is to adopt high reflectivity materials and coatings to the roof and other external surfaces of a building. The latter shares many of the benefits of the vegetation-based installations but is very often much simpler and cheaper to install. Of the many tests, a more recent one on high reflectivity roofs was carried out in Australia (Suehrcke et al., 2008), in which room and surface temperatures were measured before and after the application of a high reflectivity white paint (albedo = 0.8). Indoor air temperature reductions of about 1 K were recorded. Akbari (2007) reported his work on monitoring high reflectivity roofs in buildings in California and found that the cooling energy reduction varied from as low as 3–4% to 52%. Installation of high reflectivity roofs, as in the case of green roofs, could result in greater use of heating energy in winter. Akbari (2007) estimated that the winter heating penalty could be up to 5%. The overall energy saving taking into account both heating and cooling energy use varied dramatically
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
645
with local climates. For example, savings for buildings in Philadelphia would be typically negligible. Akbari stated that in the United States, cooing energy benefit in summer is normally greater than winter penalties. However, for the UK where active cooling in summer is not as widespread, the application of high reflectivity roofs could result in a net energy (and carbon) penalty. Both the green and high reflectivity roofs and walls could have an energy disadvantage during the winter heating season. However, this should be considered against the potential energy increase associated with active cooling if passive cooling such as a high-albedo roof is not available. In the longer term, the UK heating requirement would reduce while the cooling load would rise, thus the cool roof installations would gradually become more effective in terms of both energy and comfort. They also, of course, make an additional and very beneficial contribution to reducing the UHI intensity. A green roof and a white or high reflective roof are not directly comparable as they have significantly different constructions. However, as shown above, their potential for passive cooling and energy savings are broadly similar in the applications considered. They have different levels of structural complexity and installation costs. In addition, maintenance requirements are different. For example, during prolonged dry hot spells when the green roof is required to work harder to shelter the building, it is weakest facing levels of stress that threaten its own health. Regular maintenance and partial replanting where needed is necessary. In terms of thermal performance, there is little reason to favour green roofs or walls. A well planned and executed test programme carried out by Takebayashi and Moriyama (2007) showed that among five roof materials tested – high reflectivity white paint, green roof, bare soil, high reflective gray paint, and cement concrete – the material that generated the coolest surface temperature was consistently the high reflective white paint, both in summer and winter. This finding is not exactly surprising as it reflects the postcard images of the white painted villages on the Greek islands in the Mediterranean (Fig. 25.4). On the other hand, the numerous benefits of urban vegetation, including flood risk mitigation, promotion of biodiversity, health and well-being, as well as their cooling properties, mean that green spaces will be increasingly valued and used, as will well designed and regularly maintained green roofs and walls. The importance of many of these benefits are recognised by prominent building rating systems including the Code for Sustainable Homes, BREEAM and LEED.
25.7
Future trends
The future of buildings is zero carbon, just as they have to be sustainable in many other aspects. Yet reaching that goal is difficult, as illustrated by the
© Woodhead Publishing Limited, 2010
646
Materials for energy efficiency and thermal comfort in buildings
25.4 The white painted houses on a Mediterranean island help minimise overheating both in the buildings and the streets.
discussions about the definitions and pathways to zero carbon, and might require substantial lifestyle changes as well as technological advances. The lifestyle change is difficult to predict, particularly in the longer term. But certain trends are emerging. For example, it was pointed out that the higher temperatures in future could mean a gradual shift towards more outdoor living and parks and green spaces could be used more intensely (Greater London Authority, 2008). Lifestyle changes in turn will impact on building design, green roofs could have more of a social dimension and become better maintained and more popular, building could become more open and connected with the outside spaces. Heightened awareness of energy use could mean that people adopt a lifestyle that is more responsive to our local and seasonal climates rather than a more uniform one throughout the world and throughout the year.
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
647
Taking a siesta during summer could alter passive cooling requirements and designs. Likewise, people in hotter climates may come to accept higher temperatures and those in cooler climates accept lower temperatures. This may have implications for the pace of life and type of work that people may choose to adopt, which in turn may translate into different building design requirements. Regional difference and diversity could increase. For the more immediate future, there is a great need for high quality real performance data on the new build and the impact of materials on its carbon emissions and climate adaptation. The evolution of building design has to a very large extent been propelled by the advancement of materials. While their development in the past has allowed buildings to become ever taller, larger, stronger and more comfortable, their success in the future will depend more on their contribution to making buildings fit for an unprecedented future, where the lifestyle is necessarily zero carbon and the climate warmer and more extreme.
25.8
Sources of further information and advice
The Chartered Institution of Building Services Engineers (CIBSE) is one of the most important sources of information relating to low carbon buildings. It has been a leader in promoting the adaptation of UK buildings to climate change, having published a string of excellent technical documents on this topic, available from www.cibse.org. The Usable Buildings Trust provides much useful information about delivering real performances that match the design intent http://www. usablebuildings.co.uk. The GreenSpec http://www.greenspec.co.uk/index.html has a wealth of information about sustainable building materials and related topics. Good background and technical papers supplement practical information on material manufacturers and products. A well managed programme of interrelated research on climate adaptation is the ARCC (Adaption and Resilience in a Changing Climate). Details can be found at http://www.ukcip-arcc.org.uk. The London Climate Change Adaptation Strategy (Greater London Authorily, 2008) is an integrated strategy building on earlier work, including that of the CIBSE. The scope is necessarily wider than individual buildings and covers issues such as the urban heat island and flooding.
25.9
References
Akbari H (2007), ‘Opportunity for saving energy and improving air quality in urban heat islands’, in Advances in Passive Cooling; Santamouris M., (ed.), London, Earthscan.
© Woodhead Publishing Limited, 2010
648
Materials for energy efficiency and thermal comfort in buildings
BASF AG (2006), Influence of Thermal Insulation and Phase-Change Material on Energy Demand and CO2-Emissions in Different European Climates, Darmstadt, Germany. CIBSE (2004), Guide F, Energy efficiency in buildings, London, CIBSE. CIBSE (2008), Energy and Carbon Emission Regulations, a guide to implementation, London, CIBSE. CLG (2007), ‘Building a greener future: policy statement’, www.communities.gov.uk/ documents/planningandbuilding/pdf/building-greener.pdf. CLG (2008a), ‘Definition of zero carbon homes and non-domestic buildings’, www. communities.gov.uk/planningandbuilding/theenvironment/zerocarbonhomes. CLG (2008b), ‘Code for Sustainable Homes Technical guide’, www.planningportal.gov. uk/uploads/code_for_sustainable_homes_techguide.pdf. The Concrete Centre (2006), Thermal Mass for Housing, London, The Concrete Centre. Eumorfopoulou E A and Kontoleon K J (2009), ‘Experimental approach to the contribution of plant-covered walls to the thermal behaviour of building envelopes’, Building and Environment, 44, 1024–1038. Feng G, Cao G, Chen X and Hu Y (2005), ‘Experiment and field study of energy storage and exchange on PCM wallboard room using night ventilation’, Proceedings of the Conference on Heat Transfer in Components and Systems for Sustainable Energy Technologies, Grenoble, France. Givoni B (1998), Climate Considerations in Building and Urban Design, New York, John Wiley and Sons. Glass J, Dainty A and Gibb A (2008), ‘New build: materials, techniques, skills and innovation’, Energy Policy, 36 (12), 4534–4538. Greater London Authority (2008), ‘The London Climate Change Adaptation Strategy’, Draft Report, London. NHBC Foundation (2008), Zero Carbon: What does it mean to homeowners and housebuilders?, Watford, BRE Press. NHBC Foundation (2009), Zero Carbon homes – An introductory guide for housebuilders, Watford, BRE Press. Niachou A, Papakonstantinou K, Santamouris M, Tsangrassoulis A and Kihalakakou G (2001), ‘Analysis of the green roof thermal properties and investigation of its energy performance’, Energy and Building, 33, 719–729. Pfafferott J, Walker-Hertkorn S and Sanner B (2007), ‘Ground Cooling: Recent Progress’ in Advances in Passive Cooling; Santamouris, M. (ed.), London, Earthscan. Sanusi A (2006), MPhil Dissertation, University of Nottingham. Schossiga P, Henninga H-M, Gschwandera S and Haussmann T (2005), ‘Micro-encapsulated phase-change materials integrated into construction materials’, Solar Energy Materials & Solar Cells, 89, 297–306. Suehrcke H, Peterson E and Selby N (2008), ‘Effect of roof solar reflectance on the building heat gain in a hot climate’, Energy and Buildings, 40, 2224–2235. Takebayashi H and Moriyama M (2007) ‘Surface heat budget on green roof and high reflection roof for mitigation of urban heat island’, Building and Environment, 42, 2971–2979. Tuohy P, McElroy L and Johnstone C (2004) ‘Thermal mass, insulation and ventilation in sustainable housing – an investigation across climate and occupancy’, ESRU, Glasgow, University of Strathclyde. Wingfield J, Bell M, Mikes-Shenton D, South T and Lowe R (2007) ‘Lessons from Stamford Brook – Understanding the Gap between Designed & Real Performance’, Final Report for Partner in Innovation Project CI 39/3/663, Leeds Metropolitan University. © Woodhead Publishing Limited, 2010
26
Materials for energy efficiency and thermal comfort in the refurbishment of existing buildings
M. G i l l o t t and C. S p a t a r u, University of Nottingham, UK
Abstract: The built environment is a significant contributor to global greenhouse gas emissions. In many industrialised nations more than 40% of carbon emissions are the result of energy consumption by buildings. There is therefore significant potential through refurbishment of the existing building stock to significantly reduce energy consumption and the associated carbon dioxide emissions. This chapter evaluates the problem and provides best practice advice on refurbishment measures aimed at reducing a building’s overall energy consumption. The chapter also includes case study examples and provides details on how refurbishment measures can be assessed through post-occupancy evaluation. Key words: refurbishment, buildings, energy efficiency, post-occupancy evaluation (POE).
26.1 Introduction Buildings are the major consumers of energy and therefore major contributors to the increase in greenhouse gas emissions leading to global climate change. There has been a considerable overall increase in the total final energy consumption associated with buildings during the last 30 years. The existing building stock is responsible for over 40% of the world’s total final energy consumption, and accounts for 24% of world CO2 emissions (IEA, 2006). Using current, commercially viable technology, much of this consumption could be avoided through improved efficiency of building energy systems (De T’Serclaes, 2007, p. 4). The effective refurbishment of the building stock has significant potential for achieving large savings in primary energy consumption and associated CO2 emissions. Figures 26.1(a) and (b) show the total final consumption worldwide in 1973 and 2006. More of this data may be found in the International Energy Agency (IEA) website. Over-use of energy in buildings due to inefficiencies is a global problem. As nations develop their reliance on energy, its use in buildings will inevitably increase. As Fig. 26.1 shows, there has been a significant increase in the share of global energy consumption in China 649 © Woodhead Publishing Limited, 2010
650
Materials for energy efficiency and thermal comfort in buildings Africa Latin America 3.8% China 3.7% 7.9% Asia 6.5 Middle East 0.9%
World marine bunkers 2.6%
OECD 60.6%
Former USSR 12.5%
Non-OECD Europe 1.5% (a) World marine bunkers Africa 2.3% 5.6% Latin America 5.1% China 15.0% Asia 11.5%
OECD 47.3% Former USSR 8.1%
Middle East 4.3% (b)
Non-OECD Europe 0.8%
26.1 Total primary energy use worldwide (a) 1973, (b) 2006 (source: IEA, 2008).
and Asia. Between 1973 and 2006 the share of global primary energy consumption increased by 7.1% and 5% for China and Asia, respectively. The Organisation for Economic Co-operation and Development (OECD) nations’ share of energy consumption decreased by approximately 13.3% over the same time period. The global requirement to increase the effciency of the world’s building stock will require tailored solutions for individual nations based on local features such as building typology, building use and local climatic conditions. Figure 26.2 shows the world market energy consumption including projections, 1980–2030. In addition to the provision of energy from non-fossil fuel sources, energy efficiency will also need to play a key role in mitigating the predicted rises. Buildings are used mainly to provide shelter, places for commerce, work and leisure. Studies in the USA and elsewhere indicate that approximately 93% of people’s time is spent indoors, 5% of time is spent in transit and only 2% outdoors (Otson and Fellin, 1992). Most human activity happens
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort 800
651
Quadrillion Btu History
600
510
400 283 309
347 366
Projections 722 665 613 563
421
200
30 20
25
15
10
03
95
90
20
20
20
20
20
20
19
19
85 19
19
80
0
26.2 World market energy consumption, 1980–2030 (http:// timeforchange.org/prediction-of-energy-consumption) (sources: History: Energy Information Administration (EIA), International Energy Annual 2003 (May–July 2005), website www.eia.doe.giv/iea/. Projections: EIA, System for the Analysis of Global Energy Markets, 2006).
in buildings, and hence they are responsible for the majority of the energy use and implicit greenhouse gas emissions. From the worldwide total energy consumption, the domestic, commercial sectors and the Local Government Authority buildings represent the most important areas for decreasing primary energy consumption through improved energy efficiency measures. The residential sector is the predominant worldwide user of energy. Water heating, space heating and cooking, appliances, cooling and refrigeration represent the major uses of energy in the residential sector. Similarly, the commercial sector uses energy for lighting, heating and cooling of buildings, for cooking, for appliances (such as computers and office machines), efficient appliances and building design being the key factors in comfort and energy savings. The efficient use of energy through good environmental building design and use of efficient HVAC systems and appliances are therefore key factors for saving energy. Local Government Authorities have similarities with the commercial sector, in terms of their energy use for the operation of public buildings and street lighting, etc. In each of these cases, the refurbishment of the existing building stock could significantly help reduce global primary energy consumption and associated CO2 emissions. The process of refurbishment will generally only take place when national governments, and/or local and public authorities, get involved by encouraging and promoting energy savings through the provision of information and incentives to use energy saving measures such as insulation and energy appliances. When deciding on refurbishment measures to reduce a building’s energy consumption, it is important to first know where the energy is used. The breakdowns of
© Woodhead Publishing Limited, 2010
652
Materials for energy efficiency and thermal comfort in buildings
consumption by end use in the EU (Bowie and Jahn, 2003) and the USA (US Department of Energy, 2000) in the residential and commercial sectors are given in Fig. 26.3. Space heating is the largest component of energy use, requiring 57% in the EU and 49.3% in the USA of the primary energy demand for the residential sector and 52% in the EU and 23.3% in the USA for the commercial sector. Water heating follows at 25% in the EU, while in the USA, cooking makes up 25% of the domestic demand, accounting for the largest incremental growth in both production and consumption. Commercial buildings show a higher percentage for lighting and appliances than residential buildings, especially for the USA, as well as a significant percentage of energy used for other uses. The differences will largely be due to the building use, location (climate), typology, size and envelope construction. Understanding these differences is vitally important when deciding on appropriate refurbishment solutions aimed at reducing energy consumption in different building types located in different climates. The energy consumption by end-users in Canada has similarities with consumption data from the USA. Space heating is the main consumer of energy, followed by water heating and appliances in both sectors (Fig. 26.4). The percentages given in Figs 26.3 and 26.4 vary depending on the building construction (age and size), installations, as well as climate (different climate in different regions in USA or Canada, as well as in different countries in Europe). The next case (Fig. 26.5) shows the differences in energy consumptions in Australia in different periods of time, as well as the forecast for 2020. As can be seen from Fig. 26.5, the forecast of overall energy intensity for space heating shows a decrease by 5% in 2020 compared with 1990. This decrease may occur for two main reasons: firstly, because more people choose natural gas over fuel oil systems, and secondly, because natural gas Residential buildings EU Residential buildings USA Commerical buildings EU Commercial buildings USA
60.0% 50.0% 40.0% 30.0% 20.0% 10.0% 0.0%
Space Water heating heating
Lighting and appliances
Coking
Cooling
Others
26.3 Energy consumption by end use in EU (Bowie and Jahn, 2003) and USA (US Department of Energy, 2000).
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
653
Residential buildings
60.0%
Commerical buildings
50.0% 40.0% 30.0% 20.0% 10.0% 0.0%
Space heating
Water heating
Lighting
Appliances/ equipment
Space cooling
Others
26.4 Energy consumption in residential buildings (NRCan, 2007a) and in commercial buildings (NRCan, 2007b) by end use in Canada, 2005. 45%
1990 2007 2020
40% 35% 30% 25% 20% 15% 10% 5% 0%
Space heating
Water heating
Appliances Cooking
Space cooling
26.5 Breakdown of energy for major end uses in Australia (Department of the Environment, Water, Heritage and the Arts Commonwealth of Australia, 2008).
furnaces become more efficient. The energy consumption for water heating is forecast to reduce by 5% in 2020 compared with 2007. The decreased proportion of energy use for water heating could be due to the use of gas and solar technologies, as well as the use of efficient appliances, such as front-loading washing machines and low-flow shower heads. Cooking energy consumption represents a small percentage of the total energy consumption and over time will stay the same. Forecast predictions show a proportional increase in space cooling and appliance energy consumptions. The increase in space cooling could be due to the reduction in the cost of air conditioning units and people’s desire for these systems along with hotter dryer summers (already a possible consequence of global climate change). The balance of energy use has also changed due to the rise and predicted rise in appliance use. The proportion of energy use for appliances increased by 8% in 2007 compared with 1990. This is due to a rapid growth in minor appliances, and consumer electronics such as laptops, mobile phones and games consoles.
© Woodhead Publishing Limited, 2010
654
Materials for energy efficiency and thermal comfort in buildings
From data for different parts of the world, electricity is the fastest-growing form of energy. This growth in electricity consumption is driven by the increased number of electrical appliances used across the world, as well as the increased use of air conditioners. Electricity and heat represents 86% of the total global CO2 emissions (du Can and Price, 2008). As shown above, the energy use in buildings is largely associated with space heating and hot water provision as well as lights and appliances. Reducing energy consumption associated with these uses alone offers huge potential for saving energy in the residential, commercial and public sector. These savings will also help countries meet their own targets in accordance with the Kyoto protocol (all nations must contribute to a global reduction in carbon emissions). On a global scale, industry and research establishments (e.g. universities and government institutes) are all working to provide economic solutions to improve the energy efficiency of buildings. These solutions will constitute a potential investment in natural and human resources and can represent a potential source of private and public investment. Refurbishment solutions not only offer potential for significantly reducing energy consumption and associated CO2 emissions. The refurbishment of buildings also has other benefits such as employment opportunities, increasing the aesthetic quality of the existing stock, improved comfort conditions, reduced health problems for occupants, reduced running costs and potentially reducing the number of families suffering from fuel poverty. This process requires significant capital investment, but at the same time it could represent a significant potential for savings. Strategies, such as creating potential for loans for energy efficiency with a low or non-existent payback rate tax could leverage support from the general public, as well as investors. Refurbishment solutions will require education strategies involving training and information for public, sales people, maintenance personnel and consumers. The existing stock In the EU, more than 50% of the existing residential buildings were built before 1970 and about one-third of them between 1970 and 1990, while the annual average rate of new dwellings represents about 1.1% of the existing building stock (Poel et al., 2007). Internationally, there are differences between a country’s climate and building stock in terms of age, typology, quality and efficiency. However, world-wide the retrofit process of existing building stock is of great importance in order to improve energy performance and refurbishment, and represents a viable solution for the short and medium term. Refurbishment is about sustainable communities – keeping existing communities intact, conserving heritage, providing options for assistive
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
655
technology and allowing for climate change adaptation. This process is also motivated by practical, historical, technical, administrative and energy reasons. Likewise, existing buildings represent a significant number of the total stock of buildings; upgrading existing homes represents an immediate and sustained strategy which could reduce the energy budgets of households and nations. Refurbishment stages A case study of refurbishment should include three essential phases: preevaluation, evaluation and post-evaluation. For example, a domestic refurbishment may consist of a pre-evaluation phase which comprises the description of the house, a survey to confirm the quality and condition of the building, a future plan including construction and building services systems, a plan of possible retrofitting measures, as well as a series of computer simulations, such as environmental analysis, which include climate change scenarios for the site, calculations of carbon dioxide emissions and energy costs associated with the building, as well as an economical analysis of the entire process. The evaluation phase consists of a desktop study, which incorporates stepby-step analysis of traditional energy conservation technologies (insulation, high performance glazing, low energy lighting systems, control of the heating system, etc.) and then more advanced and substantial improvements (e.g. natural hybrid ventilation control system, innovative insulation systems, passive and active solar and micro-generation technology such as PV) improving the building envelope, ventilation, lighting and heating. In the meantime, the relationships between occupancy and energy usage should be evaluated and the performance and energy efficiency diagnosed. In parallel with this, a series of experiments could be performed to allow the testing of different aspects such as thermal performance. The post-evaluation phase consists of analysing the resultant energy savings, the experiences learned during the retrofit process and the user feedback. Building refurbishment energy issues All materials used in the construction of buildings are produced, transported and installed using energy. This is referred to as the ‘embodied energy’, which comprises all the energy required to extract, manufacture and transport a building’s materials as well as that required to assemble and finish it (Pank et al., 2002, p. 21). When making choices between the demolition or refurbishment of a building and refurbishment specifications, the embodied energy should also be taken into account. For example, many modern products such as aluminium are energy intensive, whereas timber, a material which has been used in construction since the days of early mankind, requires relatively
© Woodhead Publishing Limited, 2010
656
Materials for energy efficiency and thermal comfort in buildings
little energy to process it. However, it should be noted that the servicing and operation of existing buildings (lighting, heating, electrical equipment) uses almost ten times as much energy throughout the year as the production and assembly of new buildings (Pank et al., 2002, p. 21).
26.2
Change of use in buildings
Refurbishment has a key role to play in the change of use of buildings. Instead of demolishing buildings that are no longer used, it may be possible to refurbish them for another use. The change of use in existing buildings could keep existing neighbourhoods intact, occupied and safeguarded for the future. For communities, their buildings can represent the historic, cultural and visual fabric of a neighbourhood. The re-use of a building can be achieved if their primary structural integrity is intact. This process is used worldwide, especially in historical buildings with remarkable architecture. The material interventions used to change the function of buildings may have similarities to the original building. Different changes could be applied to buildings, e.g. the conversion of offices and public buildings for residential use, or the conversion of factories or large industrial units for public use such as museums or art galleries. Conversions will encompass specific requirements which must be considered and included in the upgrading of the building, e.g. fire precautions, hygiene, access to and use of buildings, storage facilities. The conversion is also an excellent opportunity to increase the energy performance of the building during the refurbishment process. Additionally the change of use of a building in an existing community should address the cultural aspects, the heritage and the acceptance by the community. In the early post-communism era (1990s) the economical reconstruction began for the Eastern European countries. Taking the particular case of the industrial building we can say that many of these have been abandoned after the companies that owned them were closed down. Some of them have been re-used mainly as storage depots for the goods imported from Western Europe and more recently others have been used as production places due to their low cost and immediate availability. In many cases these buildings should be saved and restored since most of them form part of the heritage of the nation. The value of these buildings is found in their architectural or structural form, uniqueness or even due to the fact that they were conceived by a famous architect. However, it is not always economic to take this approach due to the building’s location, size, capacity and the technical requirements associated with the conversion. The first case study below is an example of a conversion project which also addresses environmental concerns, while the subsequent two case studies are examples of refurbishment of residential blocks.
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
657
26.2.1 Case study: change of use in buildings – factory conversion into a city centre eco house Situated in the heart of the historic Lace Market area within the UK city of Nottingham is a fine example of a refurbishment project that has converted a derelict Victorian lace workshop into a city centre eco-home. The Nottinghambased architectural practice Marsh Grochowski was commissioned by the owner occupier, Alan Simpson MP, to create a sustainable home for himself and his family. Extensive conversion works have created a home split over three levels. The house has a double height living/dining area and three bedrooms. Figure 26.6 shows images before (derelict lace factory) and after (3-bed eco-home).
Before
After
26.6 City Centre Eco-Home Conversion Project (source: Image courtesy of Marsh Grochowski architects; photograph of the completed scheme Martine Hamilton Knight).
© Woodhead Publishing Limited, 2010
658
Materials for energy efficiency and thermal comfort in buildings
The refurbishment utilised a number of sustainable materials and technologies to reduce the overall environmental impact, minimising energy consumption and associated CO2 emissions. The existing brick exterior was clad with an external insulated render system to provide thermal insulation and weather proofing. Internally the walls were built out with a timber frame and insulated using semi-rigid insulation slabs made from wood chippings and 7–10% polyolefin fibres (90% recycled materials). The house maximises the use of natural daylight by incorporating roof lights, glass floors and light steals (shafts lined with mirrored Perspex to allow daylight to be drawn down into the spaces below). The large south facing glazed areas were equipped with solar control glass and externally mounted louvered panels to prevent summer overheating. The roof incorporates a 16 panel 3.04 kWp photovoltaic system (PV) to convert solar radiation into electricity, producing clean, emission-free electricity for the home. The PV system saves approximately 325 kg of CO2 emissions per year. The house also uses a Stirling Engine micro-combined heat and power unit (microCHP) which provides space heating, hot water and electricity through the combustion of natural gas. Water from the house’s baths, showers and washbasins is filtered in a grey water system located under the utility room floor. The treated water is then used to flush the toilets and water the plants on the outside terrace. As a result water consumption is reduced by up to 40%. Low flush toilets, a low water use shower and low energy lights and appliances were specified throughout. The following two case studies are part of the International Energy Agency and EuroACE funded project ‘Energy Efficiency in the Refurbishment of High-Rise Residential Buildings’. More information can be found at www. euroace.org/highrise.
26.2.2 Refurbishment case studies St Petersburg, Russia Torzhovskaya 16 is a 1950s five-storey residential high-rise block built in a cold climate EU region. Figure 26.7 shows the before and after images of the refurbishment project. The project consisted mainly of insulating the entire building envelope and overhauling the district heating system so that residents could monitor and regulate individual radiators within their own apartments. The total useable floor area of the building was also increased. Before the refurbishment took place the building consumed approximately 919.4 MWh/a or 323 kWh/m2 per year. After the refurbishment these values dropped to 526.7 MWh/a and 157 kWh/m2 per year. This implies a total energy consumption reduction of 43%, or 51% when taking the increased floor area into account.
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
659
Before
After
26.7 Five-storey residential high-rise block in St Petersburg, Russia (source: © OECD/IEA, EuroACE 2006 ‘High-Rise: Changing The View’, http://www.euroace.org/highrise/).
Riga, Latvia ‘Ozolciema iela 46/3’ in Riga is a typical circa 1990 CEE high-rise building comprising nine storeys and built of lightweight single layer prefabricated © Woodhead Publishing Limited, 2010
660
Materials for energy efficiency and thermal comfort in buildings
concrete panels (Fig. 26.8). The building’s façades, roof and basement ceiling were well insulated during the refurbishment. New windows were also added in addition to the complete overhaul of the heating system. The CO2 emissions per dwelling were 2442 kg/a before the refurbishment and
Before
After
26.8 A circa 1990 CEE high-rise comprising nine storeys, Riga, Latvia (source: © OECD/IEA, EuroACE 2006 ‘High-Rise: Changing The View’, http://www.euroace.org/highrise/).
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
661
1046 kg/a after, a reduction of 1395 kg/a or 57%. The measured heating energy savings were 82 kWh/m2 per year, 155 kWh/m2 per year before and 73 kWh/m2 per year after refurbishment, a 53% reduction.
26.3
Approaches to low carbon retrofit systems/ technologies
Human behaviour plays an important role in the impact of global climate change, as concluded in the Fourth IPCC Assessment Report ‘Climate Change 2007’ by the Intergovernmental Panel on Climate Change (IPCC, 2007). The general tendencies are: ∑ increase in temperature with warmer summers ∑ increase in the amount of precipitation ∑ increase in wind speed and frequency of storms ∑ increase in intensity of extreme rain in the summer, with a decrease in number of rain days. Relative to 1990, temperatures worldwide for 2100 are expected to increase by 1–6 °C depending on which study you refer to. However, there is a common consensus that temperatures will definitely rise. Therefore the change in outside temperature will provoke changes in the internal temperature, which can affect the building materials. This could have consequences in the resistance of existing building stock and therefore the structural systems may need to be adapted. The increase in temperature with warmer summers and the increase in the quantity of precipitation could lead to overheating and flooding. In the case of dwellings, these are overheated when they reach 28 ºC or more for 1% of occupied hours in living areas (TRCCG, 2008). It is therefore also important to ensure that any refurbishment addresses the potential impact of a warming climate. Refurbishment design should be future proofed so that buildings refurbished today will not have a tendency to overheat in the future. The variety of climates, different types of buildings and different energy conservation technologies implemented differs from one country to another. Therefore it is difficult to generalise the results based on different studies on different buildings. For example, in the UK, if you were to consider an energy efficiency domestic refurbishment, some or all of the following measures should be taken into consideration: ∑ roof, cavity or solid wall and floor insulation; ∑ improving airtightness – installation of basic draught proofing; ∑ insulating hot water tanks; ∑ switching from tungsten light bulbs to low-energy light bulbs – compact fluorescent or LEDs;
© Woodhead Publishing Limited, 2010
662
Materials for energy efficiency and thermal comfort in buildings
∑
replacing old inefficient boilers with high efficiency condensing boilers or low or zero carbon heating systems using renewable energy; ∑ installing double glazing or even triple glazing; ∑ zoned heating controls with timers. In the UK there are still a considerable number of uninsulated homes, probably for financial reasons and the inconvenience caused by the possible disruption to the homeowner. Depending on the thickness and type of insulation installed, the cost varies as does the reduction in energy bills. It is recommended to insulate the walls and floor at the same time and to seal the gaps with caulking to reduce the infiltration heat loss. In addition to reduced fuel bills, the additional benefits for the homeowner from insulating their homes include increased comfort, reduction of draughts, and maintaining a constant temperature throughout the home. Insulation plays an important role in the overall building energy consumption. Different materials can be used to insulate, the most common being those with a mineral base, e.g. glass fibre and mineral wool, rock wool, vermiculite, perlite and expanded clay, and those based on porous, polymeric materials, e.g. expanded polystyrene, extruded polystyrene or polyurethane. There are also natural organic-based insulators, such as cork, cellular wool, linen tow, cotton and coco fibre. Many of the latter materials are made from recyclable products. As previously stated, the type and quantity of material will have an impact on the overall insulation properties of the building. Designers should also consider where and how the insulation material is installed. Buildings constructed with heavyweight materials tend to be better regulators of internal temperature due to their inherent ability to provide temperature buffering. This quality is often referred to as thermal mass which provides high thermal inertia – an ability to store heat within the material which minimises the heat variation of the air inside the building. A low inertia building, on the other hand, will rapidly rise and fall in temperature depending on outside temperature or solar gain. Some insulation materials and some building options favour a high inertia while others do not (De T’Serclaes, 2007). If the thermal mass of the building is isolated due to the addition of internal insulation lining the internal surfaces, there may be an adverse effect on internal temperatures and comfort conditions. When sealing a building, attention must be paid to the gaps around badly fitted windows or doors. These can potentially cause more air leakage than the window itself. Virtually any opening such as letterboxes, keyholes, cat flaps, loft hatches, open fireplaces and even superfluous air bricks can contribute to ‘leakiness’. Unfortunately, existing buildings are often expensive to operate in terms of energy costs and can have indoor environmental quality problems. Most old
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
663
houses, for example, are likely to have old boilers, which have significantly lower thermal performance than today’s boiler units. It is estimated that in the EU there were around 10 million boilers in residential buildings more than 20 years old (Bowie and Jahn, 2003). When an old boiler is replaced with a more efficient one, significant savings in energy can be achieved. Boiler controls can also help to achieve maximum energy saving potential. A smart room thermostat which turns the boiler and heating pump off when the temperature has reached the required level can improve the energy savings level. Therefore programmers or time switches are useful, allowing the user to set the times when heating and hot water are required. In addition to the conventional energy efficiency solutions, designers should also consider the use of systems which make use of renewable sources, such as sun, wind, biomass, etc. Table 26.1 shows the predicted domestic energy savings for various measures. In most cases the electricity consumption for lighting represents between 15 and 20% of the electricity bill. The rest is accounted for by domestic appliances (fridges and freezers, washing machines, dishwashers and tumble driers, televisions, videos and many more), excluding cases where electrical heating is used. Even though technology is rapidly advancing and appliances are more energy efficient, the electricity consumption associated with their use is rising due to the greater ownership and the fact that more are left on stand-by mode (not fully shut down when not used) or have higher energy demand appliances like plasma TVs which use more electricity. In Australia (Department of the Environment, Water, Heritage and the Arts Commonwealth of Australia, 2008), the percentage of electricity spent on appliances increased from 24% in 1990 to 32% in 2007. In Europe, the energy label on appliances, such as refrigerators, freezers, washing machines shows the appliance’s yearly energy consumption and the energy class. ‘A’ indicates low energy consumption, while ‘G’ indicates extremely high consumption. Using the energy labelling system, a reasonable estimation of the total energy consumption can be determined for that particular appliance. An A-rated appliance will use approximately half as much electricity as a G-rated appliance. All low energy cost measures have a financial cost, which can represent a barrier in bringing the building to a more energy efficient status. For example, in 1996 Germany introduced preferential loans to finance energy efficiency and refurbishment; these were sustained by public subvention. This could be a solution for each country in order to achieve the energy efficiency through buildings and reduce CO2 emissions. Globally there are many different building standards used in practice. In recent years Europe has seen an increasing number of buildings designed to the ‘PassivHaus’ standard. PassivHaus buildings have the following properties: ultra low energy consumption, superinsulated, minimal thermal
© Woodhead Publishing Limited, 2010
Gross savings
Net savings
© Woodhead Publishing Limited, 2010
Measure
Components Energy Fuel Carbon Carbon Comfort Energy on the size (kWh/yr) Cost (kgC/yr) dioxide factor (kWh/yr) of property (£/yr) (kg CO2/yr) assumed
Cavity wall insulation Loft insulation (professional) Loft insulation (DIY) SWI external to U value of 0.35 W/m2K SMI internal to U value of 0.45 W/m2K Insulated wallpaper Tank insulation – top-up Draughtproofing Glazing E to C rated A/B rated boilers (exceptions) Fuel switching Heating controls – upgrade with boiler Heating controls – extra Community wood chip CHP Community ground source heat pumps
3 bed semi 3 bed semi
3544 1752
£91.50 £45.19
3 bed semi 3 bed semi
1503 12 356
3 bed semi
745.31 368.66
15% 15%
3012 1489
£77.86 £38.41
173.01 85.46
634.36 313.36
£38.76 £319.10
86.23 316.19 709.14 2600.19
15% 15%
1277 10 502
£32.95 £271.23
73.30 602.77
268.76 2210.16
11 680
£301.71
670.51 2458.54
15%
9928
£256.45
569.93
2089.76
semi semi semi semi semi
4020 941 743 458 1866
£112.12 £23.85 £19.17 £11.86 £43.58
230.60 53.88 42.61 26.35 97.21
845.52 197.57 156.25 96.62 356.45
15% 15% 15% 15% 15%
3417 800 631 389 1866
£95.30 £20.27 £16.30 £10.08 £43.58
196.01 45.80 36.22 22.40 97.21
718.69 167.94 132.81 82.12 356.45
3 bed semi 3 bed semi
7116 181
£502.19 1107.52 4060.92 £4.30 9.57 35.09
15% 0%
7116 181
£502.19 1107.52 £4.30 9.57
4060.92 35.09
3 bed semi Flat
1457 –2185
£34.62 £254.43
77.02 282.41 937.67 3438.12
0% 0%
1457 –2185
£34.62 £254.43
77.02 937.67
282.41 3438.12
9216
£11.47
148.80
0%
9216
£11.47
148.80
545.61
3 3 3 3 3
bed bed bed bed bed
Flat
203.54 100.54
Fuel Carbon Carbon Cost (kgC/yr) dioxide (£/yr) (kg CO2/yr)
545.61
Materials for energy efficiency and thermal comfort in buildings
664
Table 26.1 Annual savings per measure for the average 3-bed semi-detached house (weighted average of all fuels, and taking account of any correction factor) (source: DEFRA, 2008)
–1135
£79.40 1034.11 3791.73
0%
–1135
8.07 8.07 3.24 26.26 44.58 21.65 31.58 8.42 6.01 601.31
0% 0% 0% 0% 0% 0% 0% 0% 0% 0%
8 8 3 37 102 27 39 10 7 313
–£13.05 58.90 215.98 –£93.17 1415.94 5191.77
0% 0%
–482 2103
88.85 325.78 708.95 2599.50
0% 0%
103.00
377.67
8766 3068
semi
8 8 3 37 102 27 39 10 7 313
£2.08 £2.08 £0.83 £6.40 £9.46 £5.39 £7.86 £2.10 £1.50 –£42.17
semi semi
–482 2103
semi
1548 10 720
£40.81 £239.26
877
£79.68
2.20 2.20 0.88 7.16 12.16 5.91 8.61 2.30 1.64 163.99
£79.40 1034.11 £2.08 £2.08 £0.83 £6.40 £9.46 £5.39 £7.86 £2.10 £1.50 –£42.17
3791.73
2.20 2.20 0.88 7.16 12.16 5.91 8.61 2.30 1.64 163.99
8.07 8.07 3.24 26.26 44.58 21.65 31.58 8.42 6.01 601.31
–£13.05 58.90 –£93.17 1415.94
215.98 5191.77
1548 10 720
£40.81 £239.26
88.85 708.95
325.78 2599.50
0%
877
£79.68
103.00
377.67
£807.40 1030.01 3776.69 £378.89 360.50 1321.84
0% 0%
8766 3068
£807.40 1030.01 £278.89 360.50
3776.69 1321.84
2115
£192.25
248.51
911.21
0%
2115
£192.25
248.51
911.21
–1266
£97.85
57.30
210.12
0%
–1286
£97.85
57.30
210.12
Materials for energy efficiency and thermal comfort
© Woodhead Publishing Limited, 2010
Community heating Flat with wood chip CFLs – retail CFLs – direct Efficient halogens Appliances – cold Appliances – wet Appliances – IDTV’s PC mains panels Energy saving kettles LNBs Wood pellet stoves 3 bed (secondary) Log burning stoves 3 bed Wood pellet boilers 3 bed (primary) Solar water heater (4hr2) Ground source 3 bed heat pumps Micro wind (1 WP. 10% LF) Mini-wind 5 kW, 20% LF Micro hydro (0.7kWp, 50% LF) Photovoltaic panels (2.5 kWp) mCHP
665
666
Materials for energy efficiency and thermal comfort in buildings
bridges, exceptional airtightness, with controlled ventilation, providing comfortable indoor climate all year without a conventional heating system for cold months. Consequently renewable energy sources can be used more cost effectively to meet the resulting energy demand. The standards are also applied to refurbishment projects. In Germany over 71 billion of public money per year is being invested in a comprehensive programme for low energy and PassivHaus Standard building refurbishment. PassivHaus refurbishment projects include the following example which was awarded the Austrian State Award for Architecture and Sustainability. A 1950s five-storey apartment block in Linz, Austria, had the first to fourth storeys of the building refurbished over a six-month period to the PassivHaus standard. The work also included insulating the building’s cellar and the attic. The balconies of the apartments were closed-in during the refurbishment and the glazing was replaced with high efficiency triple-glazed units with integrated solar protection to prevent summer overheating. The refurbishment resulted in a 90% reduction in the monthly heating cost for a 59 m 2 flat, from 740 to 74 per month (based on an estimated energy price of 70.06 per kWh), and an 89% reduction in CO2 emissions for the whole building, from 160 tonnes per year to 18 tonnes per year. The ‘House of the Future’ initiative by the Austrian Federal Ministry for Transport, Innovation and Technology (BMVIT) has set up a detailed network for documenting all PassivHaus projects. The network has covered in total 503 (July 2006) PassivHaus building projects, primarily from Austria, and 40 international projects have also been documented. The network also identifies the importance of the refurbishment projects undertaken on old buildings to the PassivHaus standard. According to forecasts PassivHaus refurbishment projects could contribute to reductions in CO2 by as much as 3.02 million tonnes (see Fig. 26.9) (IG Passivhaus Austria, 2009). Future trends in the refurbishment of buildings to reduce energy consumption will look at ways to increase efficiency and performance whilst at the same time reducing the cost of the retrofit technology and the inconvenience to the building’s occupants through quick and easy installations. As costs reduce, the use of high performance insulations which incorporate aerogel and vacuum technologies are likely to become more prevalent due to their ability to provide high thermal resistance. Their highly insulating properties mean that retrofit insulation can be applied internally (or externally) to a building without considerably increasing the overall thickness of the external fabric of a building. This is especially beneficial when looking at applying internal wall insulation. If it is possible to use thinner material with the same insulation properties as a thicker alternative, the former solution will have less impact on the internal spaces. The implementation of the measures outlined here can help bring about significant theoretical reductions in the energy associated with the world’s
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
© Woodhead Publishing Limited, 2010
26.9 PassivHaus refurbishment projects for old buildings. From left to right: EFH Schwarz in Pettenbach, LANG Consulting; MHF of the GIWOG in Linz, architect’s office ARCH+MORE; Secondary Modern School II + Polytechnic School in Schwanenstadt, PAUAT architects; Bezirkspensionistenheim in Weiz, architect’s office DI Erwin Kaltenergger; Office building, Architects’s Office DI Gerhard Zweier (source: IG Passivhaus Austria).
667
668
Materials for energy efficiency and thermal comfort in buildings
existing building stock. However, to ensure that the measures have actually succeeded, it is important that the energy performance of refurbished buildings is monitored to ensure that the design and refurbishment aspirations are actually met.
26.4
Post-occupancy evaluation (POE)
Various definitions and interpretations of post-occupancy evaluation (POE) have been proposed. Preiser et al. (1988) define post-occupancy evaluation (POE) as a ‘process of evaluating buildings in a systematic and rigorous manner after they have been built and occupied for some time’. The Royal Institute of British Architects (RIBA) Research Steering Group (1991) defined post-occupancy evaluation as a ‘systematic study of buildings in use to provide architects with information about the performance of their design and building owners and users with guidelines to achieve the best out of what they already have’. Post-occupancy evaluation is defined in Zimring and Reizenstein (1980) as ‘examinations of the effectiveness for human users of occupied design environments’ – this study focused on the needs of the occupants. Over time POE has progressed from a one-dimensional feedback process to a multidimensional process. The first evaluations focused primarily on the performance of buildings, while the latest studies emphasise a holistic, process-oriented approach taking into account the political, economic and social aspects. It was demonstrated that in order to assess and improve the thermal performance of buildings, the metered data from POE studies is a suitable method for an initial check (Sawyer et al., 2008). Different approaches can be considered in a POE study: collecting energy usage data, temperatures, lighting levels, acoustic performance, assessing the occupants using questionnaires, rating the aspects of living comfort in a building, survey data determining the designers’ intentions, occupant comfort and satisfaction, as well as different interpretations from different points of view that could arise. An architect could use the POE study as a part of the design process by making use of the data to improve upon future designs, or even for the modification of existing spaces or performance enhancement. Improving the energy efficiency of buildings by implementing technologies that reduce carbon emissions can also potentially improve the comfort of the occupants, another aspect that can be ascertained through POE studies. However, more research must be done to determine the impact of the space usage and design on the human behaviour by analysing occupant satisfaction and perception. In order to ensure that there is significant progress towards energy efficiency in the building type that is responsible for the largest proportion of energy consumption, it is necessary to identify the benefits of POE for housing. Such a study could help in taking the right decision in
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
669
retrofitting an old house, reducing client’s future costs, increasing occupants’ satisfaction whilst at the same time increasing energy efficiency. Refurbishment measures should also maximise the value of the property and minimise maintenance costs. These are other aspects that can be assessed through an effective POE study. An effective choice of POE methods and strategy should be considered when a POE study is performed. This includes pre-visit questionnaires, semistructured interviews with the occupants, field observations during walk-through visits, physical monitoring, and experimental tests of building performance. Such a case study is underway (at the time of writing) at the University of Nottingham, where a three-bedroom semi-detached 1930s house, a common typology of home within the UK’s 25 million existing dwellings, is subject to an extensive POE study during a three-year incremental refurbishment programme (Fig. 26.10). The house is part of the Creative Energy Homes (CEH) Project, University of Nottingham (Fig. 26.11). CEH is a research and educational showcase of seven low or zero carbon houses. It is called the E.ON 2016 Research House due to the UK Government’s commitment for all new housing to be zero carbon by the year 2016. The project will investigate how the same challenge can be applied to existing homes in the most cost effective and efficient way. The project is a collaboration between researchers at the University of Nottingham’s School of the Built Environment and the energy company E.ON.
26.10 E.ON UK’s 2016 Research House.
© Woodhead Publishing Limited, 2010
670
The E.ON 2016 Research House
26.11 Creative Energy Homes.
Materials for energy efficiency and thermal comfort in buildings
© Woodhead Publishing Limited, 2010
Green Close University Park University of Nottingham
Materials for energy efficiency and thermal comfort
671
The key factor driving the project is that in the UK for domestic buildings alone, the energy used for heating, lighting and power in homes produces over a quarter of the UK’s CO2 emissions. The average household produces about 6 tonnes of CO2 every year (CLG, 2008). Table 26.2 shows the average CO2 emissions per dwelling per year for the large UK cities. There is an urgent need for affordable routes for existing home owners to reduce their energy consumption and adapt their properties to meet sustainable contemporary lifestyles. The project will explore the options for converting a typical 1930s house to a 2016 zero carbon standard. Phase 1 (year 1) is a 1930s scenario: monitor the performance of the house constructed to the 1930s standards – single glazing, no insulation, no draughtproofing and a low efficiency heating system. The second phase (year 2) involves upgrading the house to make it 25% more energy efficient than current UK Building Regulations. The main objective is also to ensure the targets are realistic for the general homeowner achieving a cost-effective standard. In phase 3 (year 3) the house will be further improved to achieve a zero-carbon status. A zero-carbon home is defined as one where net CO2 emissions resulting from all energy used in the building are zero or better (CLG, 2009). Table 26.2 Domestic energy CO2 emissions (source: UK Energy Savings Trust: Habits of a Lifetime – European Energy Usage Report) City
Average kg CO2 per dwelling per year
Reading Leicester Bradford Sunderland Birmingham Nottingham Leeds Greater London Sheffield Aberdeen City Newcastle upon Tyne Edinburgh, City of Liverpool Bristol, City of Cardiff Coventry Brighton & Hove Manchester Derby Glasgow City Southampton Plymouth Kingston upon Hull, City of
6189 5565 5539 5504 5424 5419 5333 5318 5247 5175 5150 5142 5073 5041 5035 4911 4905 4862 4814 4611 4563 4447 4395
© Woodhead Publishing Limited, 2010
672
Materials for energy efficiency and thermal comfort in buildings
In the 1930s, cavity walls had only just been introduced, and the wall of the E.ON house comprises a brick outer skin with a 50 mm air cavity and dense concrete blockwork inner leaf which has been plastered internally. The house is only one of a pair of semi-detached homes. Therefore an additional super-insulated timber structure adjoins the house to simulate the house next door thus taking into account any potential for heat loss through what should be the party wall. A research laboratory where the POE monitoring takes place is situated in this timber framed structure and in the loft space above the home. The house is occupied by a family and is fully monitored. The quantitative data (collected by more than 100 sensors that are monitoring indoor/outdoor climate and energy consumption) is being logged alongside the qualitative data, behaviour/actions of the occupants (i.e. what do the inhabitants do to make themselves comfortable and how do they use the spaces). The environmental monitoring is measured through a network of temperature (placed on the north, south, east, west wall, floor and ceiling of each room), humidity and indoor air quality sensors within the house (Fig. 26.12). Electricity use is monitored using whole house, circuit and appliance meters. Figure 26.13 shows the individual power circuit monitoring equipment installed in the electricity distribution board of the house. The highlighted area in Fig. 26.13(b) shows current transducers which pick up the current from the magnetic field produced when current flows through the individual circuit cables. The system provides disaggregated power data showing not only how much energy is consumed but where and when it is used. This is extremely valuable information to support decisions such as where and how to make energy savings. The occupancy patterns and space use are analysed using a real-time and location tracking system (supplied by UBISENSE) which uses ultra wideband radio frequency technology. This is the first time that this technology and system has been used to log occupancy patterns in domestic buildings. The sensors are located strategically in the house so that when a person moves, the system is able to detect the worn tag to within a relatively high accuracy (approximately 15 cm) in three dimensions. Figure 26.14 illustrates the virtual environment of the E.ON 2016 Research House. Software has been developed by Spataru to correlate energy and occupancy data from all the sensors in the house. This enables researchers to look at individual impacts and behaviour patterns which affect energy consumption. During the project different technologies will be tested: air source heat pumps, different types of insulation (e.g. vacuum insulation panels and vacuum glazing). The key elements of the project are to minimise fabric and ventilation heat losses from the building and to reduce energy requirements for lights and appliances. The purpose of this study is to identify the most
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
673
(a)
(b)
26.12 Environmental monitoring sensors (from the right: temperature, radiant temperature, humidity, air quality).
cost effective solutions, assess the impact on occupants, inform future stock investment and contribute to best practice. During the study a series of interviews will be conducted with the occupants. These interviews will help to gauge which measures were seen to be effective and how they impacted on their time spent in the house. The relationships between occupancy and energy usage will also be evaluated and the building performance and energy efficiency diagnosed. In parallel with this, a series of experiments will be performed in the house to allow the testing of different aspects including thermal performance and air leakage
© Woodhead Publishing Limited, 2010
674
Materials for energy efficiency and thermal comfort in buildings
(a)
(b)
26.13 The distribution panels with their individual circuits power monitoring (image courtesy of MicroWatt).
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
675
26.14 Screenshot of the dedicated software showing the locations of the sensors and occupants within the house.
testing. The POE study consists of monitoring and managing data collection and analysing data in order to predict the building performance over a period of time and after different stages of refurbishment. The data is analysed in order to report findings, recommendations and review the outcomes. An important aspect of POE is the efficiency of space allocation and space usage. This phase of the project will inform the final phase. The final phase is the most important because it must utilise the identified solutions to solve the problems and make recommendations. The POE study can help determine how well a new concept works once applied. The thermal images taken in the winter of 2008 (phase 1) are shown in Fig. 26.15. The noticeably brighter parts of the image indicate areas of high heat loss, in particular the single glazed windows, the chimneys and the roof (especially under the eaves). Besides the building performance, the behaviour of the occupants is increasingly important, because in domestic buildings the occupants exert complete control over the lights and appliances in addition to the heating system, whereas in an office environment there may be restrictions and rules put in place in order to reduce energy consumption. The occupants’ behaviour in using energy can be influenced by the following factors: the number of occupants, age and sex of the occupants, the time spent in the
© Woodhead Publishing Limited, 2010
676
Materials for energy efficiency and thermal comfort in buildings
© Woodhead Publishing Limited, 2010
26.15 Thermal images of the E.ON 2016 Research House (Phase 1).
Materials for energy efficiency and thermal comfort
677
house by each occupant in a dwelling, frequency of shower and bath use, the heating and ventilation preferences of the occupants, income and interest in energy use, comfort, costs and impact on the environment. Energy and resource waste is still significant, particularly in affluent societies, where energy costs represent only a relatively small share of total living expenses. The main problem is often human behaviour, leaving the lights on in unoccupied rooms, overheating the space or leaving the heating on while the house is unoccupied, boiling more water than necessary in the kettle, leaving machines (such as televisions, computers) on stand-by, leaving electrical chargers plugged in, etc. The energy consumption from some of the habits above, such as leaving machines on stand-by, could appear inconsequential; however the combined energy consumption could contribute considerably to the annual electricity cost. Boardman (2007) concluded that ‘behavioural change will be a vital component, whether from the different professions and trades involved, or from the occupants’. One solution is new technologies, such as portable products with wireless communications and maybe in the future with wireless power, which can power down energy consumption even when in stand-by mode. Another solution is to make the occupants pay more attention to energy efficiency by providing them with complete information about wasting energy and energy savings. Smart monitors or meters can be used to make occupants aware of how much energy their household appliances consume. In the UK, for example, because some industrial organisations had to identify solutions to cut costs on their energy bills, a few measures were applied: ∑ ∑
training awareness for the staff, awareness signs in the working area to shut down computers and turn off lights etc., ∑ turn off printers when not in use, ∑ encourage use of natural ventilation instead of air conditioning. On the other hand, in domestic buildings, the occupants control the appliances and may not have enough knowledge about the effect of energy inefficiency, and perhaps they are not concerned by their own impact on the environment. Education and information from POE energy surveys could help improve the attitude of a significant number of households.
26.5
Sources of further information
European projects related to the Energy Performance of Buildings Directive ∑
Applying the EPBD to improve the Energy Performance Requirements to existing buildings http://www.enper-exist.com/ © Woodhead Publishing Limited, 2010
678
∑ ∑ ∑ ∑
∑ ∑ ∑ ∑ ∑
Materials for energy efficiency and thermal comfort in buildings
Energy Performance Assessment for Existing Non Residential Buildings http://www.epa-nr.org/ European High Quality Low Energy Buildings http://www.euleb.info/ Development of Distance Learning Vocational Training Material for the Promotion of Best Practice Ventilation Energy Performance in Buildings http://www.ecobuildings.info/ ECO-BUILDING is an energy demonstration initiative of the European Commission (DG TREN) within the sixth Framework Programme. ECOBUILDING projects aim at a new approach for the design, construction and operation of new and/or refurbished buildings, which is based on the best combination of the double approach: to reduce substantially, and if possible, to avoid demand for heating, cooling and lighting and to supply the necessary heating and cooling and lighting in the most efficient way and based as much as possible on renewable energy sources and polygeneration. Sustainable Refurbishment of Victorian Housing: The BRE Trust, IHS BRE Press, ISBN: 9781860819360, 2006. The 1930’s House Manual by Rock I, Haynes Publishing, ISBN: 9781844252145, 2005. Knock It Down or Do It Up by Plimmer F, Pottinger G, Harris S & Waters M, BRE Press, ISBN: 9781848060203, 2008. Refurbishment and Upgrading of Buildings 2nd edn by Highfield D & Gorse C, Taylor & Francis, ISBN-10:0415441242, 2009. Construction Technology 3: The Technology of Refurbishment and Maintenance by Riley M & Cotgrave A, Palgrave Macmillan, ISBN-10: 1403940959, 2004.
The most important studies along with their results are found on the internet: ∑ ∑
Annual EIA International Energy Outlook (www.eia.doe.gov) IEA World Energy Outlook on the prospective developments of the world energy supply through 2030 (www.Worldenergy-outlook.org) ∑ Shell published three scenarios on world energy supply, under the title ‘Shell Global Scenarios 2025’ (www.shell.com) ∑ International Energy Agency and EuroACE funded project ‘Energy Efficiency in the Refurbishment of High-Rise Residential Buildings’ www.euroace.org/highrise (six case studies) ∑ The 40 percent house - http://www.40percent.org.uk/
© Woodhead Publishing Limited, 2010
Materials for energy efficiency and thermal comfort
26.6
679
Acknowledgements
The authors wish to acknowledge E.ON (UK), sponsors of the E.ON 2016 Research House & epsrc/e.on sponsors of the calebre research project.
26.7
References and further reading
Boardman B. (2007), ‘Examining the carbon agenda via the 40% House scenario’, Building Research & Information, 35(4), 363–378. Bowie R. and Jahn A. (April 2003), European Union – The New Directive on the energy performance of buildings – Moving closer to Kyoto. Available at http://europa.eu.int/ comm/dgs/energy_trasport/index_en.html (accessed June 2008). Communities and Local Government (CLG), (2008), Communities and Local Government, Energy Performance of Buildings. Available at www.communities.gov.uk/ planningandbuilding/theenvironment/energyperformance/ (accessed October 2008). Communities and Local Government (CLG) (2009), Code for Sustainable Homes. RIBA Publishing. Department of the Environment, Water, Heritage and the Arts Commonwealth of Australia (2008), Energy use in the Australian residential sector 1986–2020. Canberra, Australian Government. Department of Trade and Industry (DTI) (2003), Energy White Paper, HMSO, London. DEFRA, Department for Environment, Food and Rural Affairs (2008), Explanatory Memorandum to the electricity and gas (carbon emissions reduction) order, No. 188. De T’Serclaes, P. (2007), Financing Energy Efficient Homes – Efficient Homes Existing policy responses to financial barriers, International Energy (IEA). Du Can, S. de la Rue, and Price, L. (2008), ‘Sectoral trends in global energy use and greenhouse gas emissions’, Energy Policy, 36(4), 1386–1403. Energy Information Administration (EIA), International Energy Annual 2003 (May–July 2005). available at www.eia.doe.giv/iea/ (accessed May 2009). IG Passivhaus Austria (2009). available at http://www2.igpassivhaus.at/surface_new/ start.htm (accessed July 2009). Intergovernmental Panel on Climate Change (IPCC) (February 2007), Climate Change 2007: The Physical Science Basis, Summary for Policymakers. available at http:// ipcc-wg1.ucar.edu/wg1/docs/WG1AR4_SPM_PlenaryApproved.pdf (accessed July 2009). International Energy Agency (IEA) (2006), Energy Technology Perspectives: Scenarios and Strategies to 2050. Paris, IEA. International Energy Agency (IEA) (2008), Key World Energy Statistics, Paris. Available at http://www.iea.org (accessed April 2009). NRCan, National Energy Use Database, 1990 to 2005 (2007a), Comprehensive Energy Use Database, Residential Sector, Canada, Table 2, ‘Secondary energy use and GHG emissions by end-use’. available at http://www.nrcan.gc.ca/eneene/effeff/resuse-eng. php (accessed July 2009). NRCan, National Energy Use Database, 1990 to 2005 (2007b), Comprehensive Energy Use Database, Commercial/Institutional Sector, Canada, Table 4. available at http:// www.nrcan-rncan.gc.ca/eneene/effeff/comuse-eng.php (accessed July 2009). © Woodhead Publishing Limited, 2010
680
Materials for energy efficiency and thermal comfort in buildings
Otson R. and Fellin P. (1992), Volatile organics in the indoor environment: sources and occurrence. In Nriagu, J. O. (ed.), Gaseous Pollutants: Characterization and Cycling, New York, Wiley, pp. 335–421. Pank W., Girardet H. and Cox G. (March 2002), Tall Buildings and Sustainability Report, FLBER MLUNSELL, Corporation of London. Poel B., van Cruchten G. and Balaras C. (2007), ‘Energy performance assessment of existing dwelling’, Energy and Buildings, 39, 393–403. Preiser W.F.E., Rabinowitz H.Z. and White E.T. (1988), Post-Occupancy Evaluation, Van Nostrand Reinhold, New York, 1988. RIBA Research Steering Group (1991), ‘A research report for the architectural profession’, in Duffy, F.w.L.H. (ed.), Architectural Knowledge: The Idea of a Profession, E. & F.N. Spon, London. Roberts S. (2008), ‘Altering existing buildings in the UK’, Energy Policy, 36, 4482– 4486. Sawyer L., de Wilde P. and Turpin-Brooks S. (2008), ‘Energy performance and occupancy satisfaction: a comparison of two closely related buildings’, Facilities, 26(13/14), 542–551. TRCCG (Three Regions Climate Change Group) (February 2008), Your Home in a Changing Climate, Retrofitting Existing Homes for Climate Change Impacts, TrccG, London. Available at http://www.london.gov.uk/trccg/docs/pub1.pdf (accessed July 2009). US Department of Energy (2000), U.S. Department of Energy, http://buildingsdatabook. eere.energy.gov/ Zimring C.M. and Reizenstein J.E. (1980) Environment and Behavior, Vol. 12, No. 4, 429–450, doi: 10.1177/00139165801240.02.
© Woodhead Publishing Limited, 2010
27
Application of design and passive technologies for thermal comfort in buildings in hot and tropical climates
M. B. G a d i, University of Nottingham, UK
Abstract: The indoor thermal environment of buildings is usually influenced by the outdoor environment (e.g. climate, landscape and urban pattern) and building design (e.g. building materials, form and planning). Controlling thermal interaction through the building envelope is important for maintaining indoor thermal comfort and therefore it requires proper selection of thermal control strategies and building materials. This chapter looks into the impact of climate on human thermal comfort and urban patterns and building form and fabric in tropical regions. It explores thermal comfort criteria derived from laboratory and field experiments. Published data on thermal comfort illustrate how people respond differently to similar environmental conditions due to factors such as adaptation. The chapter then presents a number of examples from traditional and modern architecture to illustrate the integration of passive cooling and heating technologies into buildings and how these are applied using conventional and more advanced modern building materials. Finally mathematical modelling of known passive heating systems such as Trombe-mass wall, water wall and solar chimney is explained with some performance data. Key words: thermal comfort, traditional architecture, building materials, passive cooling and heating.
27.1
Thermal comfort in different climates
To be thermally comfortable, means to experience a state of mind which expresses satisfaction with the thermal environment. The following section introduces the importance of this concept when considering different climatic regions that exist now or, with climate change, in the future.
27.1.1 Introduction Due to biological differences, thermal comfort may not be equally applicable to all building users. This is a particularly important fact to consider when a large proportion of research studies are conducted with respect to climatic regions in Western Europe and the USA, e.g. formal guidance documents from bodies such as the Chartered Institution for Building Services Engineers (UK), 681 © Woodhead Publishing Limited, 2010
682
Materials for energy efficiency and thermal comfort in buildings
or The American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE). In addition, with the changes and predictions brought about by climate change we can expect global temperatures to rise which has implications for future-proof building design strategies and low energy approaches to meeting thermal comfort requirements. To design for thermal comfort indoors, it is usually recommended to satisfy at least 80% of the building occupants. Within thermal comfort, the core temperature of the body should be maintained within a small range (around 37 °C) regardless of fluctuations in the thermal environment. To maintain thermal balance, heat is usually produced within the body at all times. Heat is also exchanged with the enclosing environment through various modes. Indices have been developed to model and predict such thermal interaction and the thermal response of the human body. Attempts to develop thermal indices which model and predict the thermal interaction between the human body and its surrounding environment are continuously being made, by means of theoretical, as well as subjective investigations. A comfort index presents the combined effect of a number of parameters (personal and environmental) on the thermal sensation and response of the human body to the thermal environment. Thermal comfort is influenced by the following parameters: ∑ ∑ ∑ ∑ ∑ ∑
metabolic rate clothing thermal resistance mean radiant temperature air temperature air velocity vapour pressure.
In addition, there is also a sub-group of parameters which are related to and influenced by changes in the main parameters. An increase in metabolic rate may result in increase in the rate of sweat secretion through the skin as a measure to maintain the core temperature necessary for thermal comfort and survival. The secondary parameters are: ∑ ∑ ∑ ∑ ∑ ∑
sweat secretion rate skin temperature skin wettedness clothing wettedness and permeation to moisture clothing fit and air movement under and within clothing clothing surface temperature.
Thermal comfort is achievable under different combinations of these parameters. Thermal indices vary in their assessment of the effect of each parameter on thermal comfort.
© Woodhead Publishing Limited, 2010
Application of design and passive technologies for thermal
683
27.1.2 Global thermal comfort criteria One of the well known earlier models for predicting human thermal response was that developed by Fanger in 1970. Fanger recommended an optimal temperature for thermal comfort (25.6 °C) which was the result of subjective experiments conducted on persons living in the Northern Temperate zone (Kansas City and Copenhagen). For some time, Fanger’s comfort theory was considered by many designers to be a universal source of criteria for human thermal comfort. Fanger developed his well-known comfort equation after extensive experiments on human subjects. With respect to application of the comfort equation to tropical regions, a comparison is given by Fanger against experimental results with European and Asian residents in Singapore (Ellis, 1953). The comparison gives 27 °C as the optimum for the subjects when relative humidity was 80% and air velocity was 0.4 m/s. A second field study, referred to by Fanger and conducted by Webb in 1959, gives 28.5 °C as the optimum temperature for approximately similar conditions and location. Allowing the indoor temperature to drift along the perimeter of the comfort zone can save energy in both heating and cooling seasons (McNall et al., 1978). Even by controlling the indoor temperature to reach the limits of the comfort zone, a saving of up to 10% is possible (Fleming, 1979; Zmeureanu and Doramajan, 1992). A house temperature survey was conducted by the Building Research Establishment over the winter and summer seasons of 1991/92. A total of 515 occupants were interviewed in the survey. The reported thermal sensation during the winter survey produced neutral temperatures which were 5 °C lower than those predicted by the ISO 7730 algorithm which is based on Fanger’s Predicted Mean Vote (PMV) model. In summer the discrepancy was 3 °C (Oseland, 1994). At approximately the same time, a different investigation was carried out in five naturally ventilated office rooms at the University of Reading in the United Kingdom (Croome et al., 1992). Results showed differences of 0.1–2.4 K between measured neutral temperatures and predicted temperatures using Fanger’s PMV model. Fanger’s model overpredicted the neutral temperatures. This finding is in agreement with other works by Schiller in 1988 and Brager in 1992. The Reading experiment also illustrated that for the UK weather when the outdoor temperature is 10 °C, an energy saving of 8.5% could be achieved by lowering the indoor temperature by 1.0 K. People’s tendency and ability to adapt to their environment were investigated by Humphreys in 1970, 1973 and 1975 among schoolchildren in the United Kingdom and office workers abroad. He noted a strong correlation (0.96) between the observed comfortable (neutral) temperature indoors and the mean indoor air or globe temperature. The correlation is based on 36 neutralities
© Woodhead Publishing Limited, 2010
684
Materials for energy efficiency and thermal comfort in buildings
which showed a range of 13 °C. One of the reasons given by Humphreys for this range is the expected difference in clothing across the field studies which is estimated to be one unit clo. As the indoor thermal environment is often related to the outdoor climate, Humphreys later introduced the neutrality temperature as a function of the mean outdoor temperature (Humphreys, 1976). A similar correlation coefficient (0.97) was obtained by Humphreys for the neutrality in the non-air-conditioned building which was better than the neutrality for the air-conditioned building, (0.56). The lower correlation is reasoned to be the artificial thermal environment inside the air-conditioned building being less influenced by the outdoor weather. Humphreys calls these relationships ‘adaptive model’. Humphreys later supported his theory by further work (Humphreys, 1979, 1981). In 1992, during the Second World Renewable Energy Congress, Humphreys published a new study which highlighted the bias between the actual Mean Vote ‘MV’ obtained from field studies and the Predicted Mean Vote ‘PMV’ obtained from the ISO 7730 algorithm (based on Fanger’s model). The average (bias) was found to be 0.8 on the PMV scale. Considering the scale unit which is equivalent to 3 °C of indoor temperature, it follows that the average discrepancy is about 2–3 °C. When plotted against the mean room temperature the PMV was about 1.5 units lower than the actual PMV at 20 °C and about 1.5 units higher at 33 °C. In his neutral temperature survey, Humphreys specifies that the data were reports of field studies published by Baillie et al. in 1987, Griffith in 1990, Schiller in 1990 and Dedear and Auliciems in 1985. The work of Dedear and Auliciems in 1985 was carried out in six field studies in three Australian cities with vastly different outdoor climatic conditions. The Australian experiment presented some differences between observed neutral temperatures for non-air-conditioned buildings at latitudes 37° and 27°. The 10° difference in latitude, together with the geographical variations, resulted in 3.8 °C difference in observed neutral temperatures. The respective difference given by Fanger’s model is only 1.2 °C. Dedear and Auliciems’ model produced a 0.5 °C difference. The model which gave a temperature difference nearest to the observed is Humphreys’ model of 1975. Its differential result is 3.1 °C. Next nearest to this value is the 2.8 °C difference produced by Humphreys, model of 1976. The 1975 model is based on indoor mean temperature while the 1976 model is based on mean monthly outdoor temperature as input. For latitude 37° (Melbourne City), the discrepancy between Fanger’s model and the observed neutrality for non-air-conditioned buildings is 3.2 °C. In contrast, the discrepancy between the observed neutrality for the same type of buildings and latitude and the neutrality resulting from Humphreys’ model of 1976 is only 0.7 °C. According to its latitude, Melbourne’s climate should be classified as temperate.
© Woodhead Publishing Limited, 2010
Application of design and passive technologies for thermal
685
Not far from Dedear and Auliciems’ region of study, there was another subjective experiment conducted in India by Sharma and Sharafat in 1986. Their proposed chart for the tropical summer index (TSI) which was plotted on a psychometric chart, indicates that about 70% of the Indian subjects who participated in the experiment felt comfortable at an index value of 27.5 °C. Within the same geographical zone, another published field study, conducted in Pakistan (Humphreys, 1994), has shown that it is not only Fanger’s comfort model which is not valid for world-wide applications, but also the design temperatures recommended by the well-known ASHRAE Standards. Humphreys’ research work in Mingora City recommended 30 °C as a good summer maximum temperature. This is, according to Humphreys, associated with slowly rotating ceiling fans (0.1 m/s) and moderate humidity. In winter, 15.5 °C is recommended as the comfort temperature which is associated with office workers dressed in typical traditional Pakistani winter clothing. The thermal comfort zone concluded by Humphreys’ work is clearly wider than the comfort limits recommended by ASHRAE Standard 55-81. Differences in comfort temperatures have also developed over the years. Changes in comfort temperature in the last few decades occurred for a number of reasons. These include changes in clothing, lifestyle and diet and development in buildings’ construction and thermal control systems. A survey of domestic temperatures over the period 1946 to 1978 in the United Kingdom was published by Hunt and Steel in 1979. It represents clear evidence that indoor domestic temperatures have risen by a rate of 1 K per decade.
27.2
Climate impact on urban pattern and building form and fabric
27.2.1 Impact on urban pattern and building form Prior to the stage of building design, a planning process on a larger scale is usually undertaken. This involves the plotting of streets in the urban areas required for different functions as in residential, industrial, commercial and open public spaces. Major decisions are taken in consultation among various authorities which will ultimately influence and even constrain the architect and the engineer in their attempts to perform thermal design of individual buildings within the pre-set urban fabric. Planning decisions are also governed by the available resources and the requirements such as density and type of traffic, road intersections, road-related services, drainage patterns and view. Unfortunately, renewable energy sources are often ignored or given token consideration. When environmental elements are considered, as they have been in the past, the planning process tends to make the thermal designer’s
© Woodhead Publishing Limited, 2010
686
Materials for energy efficiency and thermal comfort in buildings
job much easier and successful. Streets are properly laid, public spaces are adequately planned and green areas are conveniently integrated within the urban grid. Street planning Streets are important because of the need for communication between different sectors of the town and the provision of services for inhabitants. For the thermal designer, they also control the spacing between buildings, their orientation and distribution of indoor spaces. Spacing within buildings will determine availability of ventilation, daylight and solar energy. Proper spacing is usually ensured by consideration of the spacing angle. This is the vertical angle between the horizontal and a line extending from base of a wall up to the top edge of the opposite wall. Typical spacing angles which satisfy heating and daylight requirements in the tropics fall in the range 30–45° (Evans, 1980). Street spacing can be determined not only by heating and daylight needs. There is also the need for summer cooling which may well contradict such values recommended for the spacing angle. An expensive compromise solution is often to increase wall insulation and shading on the street side. Even with this solution, there still remains the problem of urban heat accumulating within the street and enhanced by traffic and solar absorption on the tarmac. The heat absorbed and stored in the street floor during summer days needs to be allowed to radiate to the sky sink by long-wave radiation. A significant parameter in this process is known as the view factor to the sky dome. Nowadays, streets are becoming more packed with cars which are a disturbing source of pollutants. These pollutants need to be dispersed from pedestrianised areas and near residential and other sensitive public buildings. Dispersal of pollutants is achieved by adequate wind movement within the urban environment. For wind to blow normal to the street axis this can be a problem. Narrower streets and high buildings can create wind shading between buildings. They can also induce turbulence and street eddies which could blow fumes through windows and main entrance doorways. Studies on the effect of street cross-section ratio on pollutant dispersal concludes that the height/width ratio should not exceed 0.65 (Oke, 1988). In hot dry regions, compactness of urban layout has been a dominant feature of town planning in the past and continues to be promoted in modern times. Building form The courtyard is one of the well-known building forms that was adopted in different parts of the world, especially in hot dry regions. The courtyard form created or helped to create the compact urban layout in tropical regions
© Woodhead Publishing Limited, 2010
Application of design and passive technologies for thermal
687
known for their hot dry climate. Overheating of indoor spaces in summer can reach intolerable conditions and care is therefore needed to reduce the environmental impact on the building and its occupants. This problem is still facing building designers in the tropics today and often inspires them to reconsider the adoption of traditional strategies such as the courtyard concept in their design process. In 1979 Mohsen conducted a study which was concerned with investigating the relationships between geometrical parameters of the courtyard form and its thermal performance in relation to solar radiation (Mohsen, 1979). A computer model was developed for the purpose which facilitated the optimisation of the courtyard’s interaction with the sun. A detailed simulation was carried out employing real climatic data for Egypt. Mohsen’s study shows that not every courtyard can be a desirable one. It also illustrates that careful consideration to the courtyard dimensions should be made to achieve a balanced year round performance, that is if the courtyard is used in its usual conventional form. Al-Azzawi (1992) pointed out that incorporating a courtyard in a building does not necessarily indicate that it is intended to alleviate summer conditions. In contrast to the courtyard is the box-like building form, which was investigated by Olgyay in 1963. He tried to find the building form which gains the lowest amount of heat in summer and loses the highest amount of heat in winter. For the case of building in a hot dry climate, Olgyay found that a rectangle with plan ratio 1:1.3, was the optimum when the long side is oriented in the east–west direction. He also suggested creating an open space within the building. Roof form Studies on curved roofs in general highlight their preference over flat roofs which is based on noted lower indoor summer temperatures associated with the curved roofs (Konya, 1980). The indoor thermal environment is a function of the outdoor thermal conditions. A major source of heat in hot regions is the sun. In these regions, during summer the sun is at a high altitude which is nearly normal to the horizontal surface at noon. A flat roof will be completely exposed to the sun while a curved roof, depending on its curvature and orientation, is partially exposed and partially facing away from direct irradiance. The solar radiation is actually ‘diluted’ on a curved roof (Olgyay, 1973) and is spread over a larger area resulting in reduced heat transmission through the roof shell (Fathy, 1973). Due to their climatic benefits curved roofs have been investigated for possible integration in modern buildings (Gadi 2000a,b,c,d,e,f). Their influence on building ventilation performance has also been studied using CFD computer simulations (Asfour and Gadi, 2007a,b,c).
© Woodhead Publishing Limited, 2010
688
27.3
Materials for energy efficiency and thermal comfort in buildings
Climate impact on building fabric
27.3.1 Thermal insulation An important component in the passive system is thermal insulation. Movable insulation reduces heat loss during winter nights and consequently increases glazing temperature for direct gain solutions. This reduces the mean radiant temperature asymmetry for the occupants and therefore reduces thermal discomfort. Movable insulation could be hinged panels, sliding shutters or rolling shades. It can also be installed externally or internally, with respect to room or even integrated within the glazing panes. Rolling insulation materials have the advantage of occupying a small volume during operation and storage which can be hidden within the building components (Moore, 1993). They may be made from quilt-like fabrics which can resist heat transfer and reflect thermal radiation. For this type of insulation to be effective, it has to be made to allow no or minimum infiltration to reduce heat loss in winter due to wind action and any pressure differences through the building. Airtightness may be provided by magnetic tape on the edges of the roller. Rolling insulation has also been produced in the form of layers of highly reflective flexible plastic films which are separated, but linked to each other by curved plastic strips. These strips flatten when the insulation is rolled up and expand when rolled down. The benefit of the plastic strips, besides strengthening the insulation, is to reduce convective currents between the main insulation layers.
27.3.2 Glazing There are several glazing types which include clear, grey, heat absorbing, light reflecting, infra-red reflection and infra-red transmitting glazing. Materials used in the glazing could be glass, perspex, plastic or transparent fibres. Clear glass is the most common in building practice which is transparent to visible radiation. Heat absorbing glass is less transparent to visible radiation and thus more absorbent to infra-red radiation. Reflective glass is produced by depositing a light reflective film on transparent glass in order to reflect both the visible and invisible portions of the solar spectrum. Some plastics (polyethylene), are transparent to upper infra-red radiation. This type of cover is useful in passive radiative cooling systems as it permits thermal radiation emitted by roofs to the sky at night.
27.3.3 Thermal storage There are various forms in which thermal storage components are usually integrated in a passively heated or cooled building. These include Trombe walls, water walls, solariums and roof ponds. However, some of these forms
© Woodhead Publishing Limited, 2010
Application of design and passive technologies for thermal
689
are often used in combination with each other or assisted by a different technique such as an earth-air tunnel and a wind tower to enhance their performance. Barra (1979) conducted a theoretical study into the free convection within a Trombe-like system. The main difference between the two concepts is that the thermal storage in Barra’s system is located within the room. This strategy is intended to improve the system efficiency by reducing thermal losses during off-sunshine hours and providing better control of the indoor thermal environment. A conventional Trombe wall system is often employed for both winter heating and summer ventilation. In certain regions, where ventilation is the main requirement for inducing human thermal comfort, a Trombe-like system known as a solar chimney is preferred (Awbi and Gan, 1992). That is because its channel height, which is an effective parameter in producing a higher ventilation rate, can be extended even above the building roof resulting in a larger air density gradient between its vents. Studies on solar chimney performance highlight the influence of channel width to height ratio and the chimney orientation on the mass flow rate and the total heat storage within the chimney structure (Bouchair et al., 1986, 1988). A solar chimney may also be built as part of a roof parapet where its ventilation performance can be enhanced by wind action (Khafaji and Murta, 1989). Thermal performance of buildings incorporating roof heating and cooling systems such as water ponds has been investigated in many parts of the world. The use of water sealed in PVC bags of 20 cm depth on a roof covered by movable insulation, in California, USA, was found to be adequately capable of heating or cooling a building to acceptable thermal comfort levels (Niles, 1976). Evaluation of the performance and efficiency of any solution, however, not only depends on its thermal and ventilation characteristics but also on user acceptance and satisfaction (Tsapos, 1992).
27.4
Approaches and lessons learned from traditional hot-climate architecture
27.4.1 Introduction The traditional strategy of creating an adaptive living environment was applied at various levels, from town planning to construction of dwellings and planting of trees. The whole process was, no doubt, carried out at a local level, i.e. with local labour and materials. Most builders in the past were familiar with the climate in which they were building. They were also aware of the means to benefit from certain climatic elements and overcome others which were less favourable. From a number of tours through North
© Woodhead Publishing Limited, 2010
690
Materials for energy efficiency and thermal comfort in buildings
Africa, the present author sadly noticed that many traditional settlements have become ruins and were replaced by ‘modern’ concrete towns. Such change came as a result of factors including a new lifestyle.
27.4.2 Traditional passive cooling and heating strategies Although often ignored, the abundant examples of traditional architecture undoubtedly represent a dominant part of human civilisation. Traditional dwellings have, naturally, enabled man to survive the extremes of heat and cold, provide security for his family, store food and goods and above all preserve his cultural and social structure. In many examples of traditional architecture the environmental factors which influence building forms are clear and well defined. Culture and climate have combined to produce unique architectural forms and expressions which are, of necessity, direct and effective. The city of Marrakech, Morocco The city of Marrakech, located in Morocco at latitude 31.5° North and longitude 10° West, has three climatic zones. The first zone has a cool day with average temperature 20 °C and moderate humidity (55%), and a cold night with average temperature of 9 °C and 50% RH. The second zone has comfortable day-time conditions and cool night with average temperature 13 °C and 80% RH. The last zone is dominated by an overheated period with average temperature reaching 35 °C which is associated with 30% RH. This shows a need for both cooling and heating. These needs can be mostly met by natural means such as controlled solar gain, air movement and proper structure and planning (Baroum, 1983). The traditional house in Marrakech is introverted. Rooms are arranged in two or three storeys around a central courtyard which is paved with marble and decorated with a fountain and vegetation (orange or lemon trees). The inward looking of the building leaves the outer skin free from major openings. This allows neighbouring buildings to be attached to each other, thus reducing the impact of solar radiation on the walls. It also generates a very compact urban layout which is characteristic of the city of Marrakech, where the streets are pedestrianised and could easily be shaded by local plants and organic materials. The high ceiling increases the overall height of the courtyard walls which consequently shades the courtyard floor against direct sunlight in summer for most of the day. The courtyard ground with its vegetation and fountain acts as a cooling and humidifying system. The day-time cooling potential is improved by the high thermal mass of the building structure.
© Woodhead Publishing Limited, 2010
Application of design and passive technologies for thermal
691
The mountain dwellings of Morocco On the rocky parts of this region, where land is as needed for shelter as for planting, dwellings are usually laid separated from each other by steep ravings. Each localised group of households shares a mosque which is their central meeting place where many administrative affairs for the village can be accomplished. This is often known as the mosque community. Another important element of this small settlement is the market, which is located away from the village on a separate site within nearest distance to neighbouring villages. Dwellings are built of 2–4 storeys and rooms are grouped around an open court which sometimes reduces to a central air shaft often incorporating a staircase. This sort of different solution is probably produced by the cold climate which is characteristic of mountain regions, where compactness of the indoor spaces is desired to minimise heat loss and maintain most of the heat generated within the dwelling by the relatively large number of occupants. Family guests are usually received in a special room on the upper floor with its own entrance and staircase. Hosting the guests at the top of the house, which is the coolest part in summer (the season of social ceremonies), is based on the well-known deep-rooted hospitality. Stones, either dry or mortared, are the main building materials. The back walls of the house are usually part of the rocky slope of the mountain. Walls are often built with the help of wooden forms which are filled with stamped clay, mixed with straw or gravel. The Mzab valley, Algeria Mzab is an ancient river valley located in rocky surroundings where five towns were built almost 1000 years ago. These towns are known as El Ateuf, Bou Noura, Beni Isguen, Melika and Gardaia which is the largest of the group. It was built 500 m above sea level at latitude 32° 30¢ North and longitude 3° 45¢ East. Average winter daily air temperature in the area is in the range 10–12 °C with lowest temperature of 1 °C. In summer the average daily temperature range between 33 and 40 °C with a high of 50 °C. Traditional building materials are sand, adobe, stone, lime, gypsum and palm product. Walls are thick and constructed from stones while roofs are built from palm materials, lime and adobe. Internal wall surfaces are gypsum plastered. Houses are inward looking with relatively large indoor living areas. Due to the intense heat and strong sunlight, the courtyard is not fully open. Part of the courtyard roof is used as a terrace around which one or two rooms are built for night time activities. Some of the courtyards are oriented south, apparently as a response to summer and winter solar positions. The internal surfaces have a light mixed colour which diffuses daylight with minimum glare. Based on the author’s personal experience in
© Woodhead Publishing Limited, 2010
692
Materials for energy efficiency and thermal comfort in buildings
this region, it can be confidently stated that the Mzab architecture is a very strong interaction between man and his environment. The town of El-Oued, Algeria The town of El-Oued is located in the Souf region which is made up of 19 oases in the southern part of Algeria about 600 km from the capital Algiers. Each house incorporates about 10 to 20 domes which are arranged around a courtyard. Larger public buildings, such as mosques, may employ as many as 80 domes supported on rows of columns. In nearby villages, houses also incorporate vaulted roofs, which present the village as one harmonious community (Fardeheb, 1988). Walking through the streets of El-Oued even on a December afternoon gives the sense of warmth, perhaps due to the sheltering effects from wind provided by the small width of the streets (1.5 m) and the relatively high walls (8 m). This is in addition to the partial cover of the street roof, sometimes by vaults. In summer one could easily imagine the scenario. A properly shaded pedestrianised area, even at noon when the sun is at about 80° from the ground. Underground dwellings in Libya Underground dwellings in Libya are mostly found along the hillsides of the city of Garian, 30.5° N and 9.5° E. The average air temperature in July is 30 °C and the average January temperature is 8 °C. Due to high altitude (1000 m), this region experiences high wind speeds in winter, 10 m/s. Once a plot of approximately 15 m² is dug, then rooms are dug on its sides, each with a small entrance door and an arched roof, basically for structural reasons. All interior surfaces are plastered white to improve daylight levels indoors. The present author visited the city of Garian, which is about 80 km from Tripoli on two occasions during winter and summer. Having stayed in a nearby modern house, the author was able to take two-interval measurements of air temperature (at 6 and 15 hours) inside and outside the modern as well as one of the underground houses. The modern house was a small ground floor dwelling with a relatively high thermal mass (2000 kg/m2 of floor area). The walls were 35 cm thick and built from sand–limestones while the roof was flat and built from 25 cm concrete slab. During summer, the outdoor air temperature varied from 25 °C in the morning to 36 °C in the afternoon. These readings coincided with constant indoor temperatures of 25 °C in the old house. In the modern house the indoor temperature varied from 26 °C in the morning to 29 °C in the afternoon. The high thermal mass of the modern house resulted in the small temperature range indoors. The constant indoor temperature in the old house is obviously due to the ground’s high heat capacity. Both houses were comfortable in summer.
© Woodhead Publishing Limited, 2010
Application of design and passive technologies for thermal
693
In winter, the ambient air temperature in the morning was 1 °C while in the afternoon it was 10 °C. Again the old house experienced a constant temperature of 20 °C. The modern house average temperature was 11 °C. The city of Ghadames, Libya This is a unique example of traditional architecture. Although it is built above ground, the town seems from within as if it is built underground. Even streets are covered except for gaps, often small holes, to allow for daylight. Having visited the town twice in 1982 and 1988, the author found it difficult to travel through its streets without a guide from the local people. As a result of its architectural, artistic and social values, it was consequently inscribed by UNESCO, in 1976, in the World Heritage List of Historical Monuments. Ghadames displays traditional craftsmanship, housing organisation reflecting social structure, and urban design appropriate to harsh climatic conditions. All these features are blended beautifully into harmonious traditional architecture. Ghadames is believed to be over 600 years old. The town of Ghadames is located within a desert landscape at latitude 30° N and longitude 9.6° E, on a joint border location between Libya, Algeria and Tunisia. Mean maximum and minimum ambient temperatures in summer are 40 and 22 °C, respectively. In winter the respective temperatures are 18 and 4 °C. Sunshine is experienced for 12 hours in summer and for 6–8 hours in winter. Relative humidity is generally low varying from 20% in summer to 48% in winter. Measurements of air temperature taken during the author’s summer visit to Ghadames show a clear and impressive picture of the thermal performance of the traditional Ghadamesian house compared with new houses built across the road. On a summer day, while the ambient temperature was 44 °C, the air temperatures inside the old and the new houses were respectively 26 and 38 °C. There are approximately just over 1000 houses in Ghadames, built interwoven and overlapping with each other and within an area of 30–50 m2. Houses are built on three floors where rooms are arranged around a courtyard. The courtyard is of double height and is closed except for a hole in the middle. All kitchens are built on the roofs for two possible reasons. One reason is thought to be social, as the roof was usually preserved for women while men occupy the ground level. Another reason is possibly related to the heavy use of the kitchen during the main meal which is lunch. Lunchtime coincides with the period of high outdoor temperature and intense solar radiation. Locating the kitchen on the roof is one way of reducing heat input within the house, which is a useful strategy during summer. In winter, however, it also means losing a potential source of heating. Considering the large traditional family size, the amount of heat lost could, at least partially, be compensated by people’s heat output. The roofed streets, on the other
© Woodhead Publishing Limited, 2010
694
Materials for energy efficiency and thermal comfort in buildings
hand, contribute to maintaining the street air temperature slightly higher than outdoor ambient temperature in winter and much lower in summer. This is due to wind sheltering in both seasons and also as a result of solar shading in summer. Solar exposure in winter could have increased street temperature, if it was not roofed but such benefit could well be counterbalanced by convective heat loss from walls due to funnelled strong winds in the narrow streets. Walls are constructed from stones joined by mud and plastered by lime or gypsum. In inner parts of the town, walls are constructed from rammed earth. Roofs and floors are built from palm trunks, which are cut into four pieces and shaped to have triangular cross sections. The palm trunks are covered with palm leaves and mud-lime-gypsum mortar, which is strengthened and waterproofed by animal dung. Traditional architecture in Egypt Architecture around the river Nile offers many interesting examples of traditional architecture in Egypt. Some of these examples date back to Pharonic Egypt, which were mostly of spiritual nature. They include the temple of Ramses II and the Great Pyramids. They were built from limestone and granite. On a smaller scale, there are also houses which were constructed from mud bricks. On the Nile one can also see some traces of the Nubian villages, near Aswan, a city famous with its great dam and man-made lake which was created during the 1960s. Nubian houses are compactly built with a mixture of flat, domed and vaulted roofs. The main building material is clay which is dug out of neighbouring hills. This is usually mixed with straw and animal dung to add structural strength and waterproofing. Each house is built with an open courtyard on one side and a number of rooms arranged on the other sides. There are two distinct rooms in the house, one for guests which is covered with a vault and the other is used for sleeping and sitting during summer. The latter is flat roofed with palm leaves. The Nubian villages are planned with a main mosque somewhere in the middle as a focal point. The streets are narrow and winding and naturally lead to the central courtyard of the mosque. The mosque is built from massive walls and thick vaulted roofs, which is a well-known strategy for delaying overheating inside until late at night and at the same time work as an adequate sink for heat released from people attending Friday prayers. Windows are usually high and small. Their location just under the roof naturally induces stack ventilation through the building. The most outstanding of all traditional examples of architecture in Egypt can be found in the old part of Cairo. The streets of Cairo are narrow and partially shaded from direct sunlight and sheltered against wind. Houses are of the courtyard type. Some courtyards are fully open while others are
© Woodhead Publishing Limited, 2010
Application of design and passive technologies for thermal
695
covered with a clear storey in the middle. Houses also incorporate wind catches which are open to the courtyard in a uniquely combined natural ventilation system. Measurements of air speed and direction, taken in 1973 by researchers from the Institute of Third World Studies in London (Farouk et al., 1973) illustrate the effects of two forces (pressure and suction) acting in the same direction. Outdoor airflow is scooped downward through the wind catch then sucked upward through the clear storey above the middle hall. On its journey through the house, the air is cooled by a water source either along the wind catch or on the house floor. Even under calm wind conditions, the large difference in height along the clear storey creates a temperature gradient which naturally leads to an upward current of air through the space. The presence of thick walls, roofs and the ground provides a large sink for storing the coolness that is produced by the whole system. Traditional roof construction consists of palm trunks covered with 10 cm of lime mortar and 10 cm of mud, then finally finished with light-coloured tiles. Ground floor walls are much thicker and heavier than upper floors. They are built from 40–120 cm limestone. Upper floor walls are built from 15 cm bricks. Another feature of old traditional houses in Cairo is the design of windows in a way that reduces glare, overheating in summer and at the same time preserves privacy which was and still is considered in some quarters of the city as an essential requirement. Each window is covered on the outside by a wooden lattice with small often circular holes. Some local people claimed that the wood actually absorbs some of the humidity in the air passing through the lattice. On the urban scale, the old city of Cairo seems to have been planned in response to local climatic constraints. Major streets run north–south from which a number of other narrower streets branch along in an east–west direction. East–west streets are partially shaded by overhanging upper floors at each side. Street intersections are the most exposed to direct sunlight. Noor (1984) analysed the results of a full-scale thermal study which included traditional as well as modern housing in Cairo. During the period from July to September, roof temperatures at 14:00 hours were 5–6 °C lower in the traditional house. At night, however, a reverse situation was noticed, though with a smaller difference. During the same period, a temperature difference of 11 °C was recorded between the roof and the indoor space of the traditional house. Planning and design of the old Cairo also show an excellent degree of integration between function and fabric. Vertical piers in the walls form convenient spaces for sitting and built-in cupboards. The relatively large height of the walls within the main hall is broken into small horizontal strips by wooden frieze running around and confining some decorative work (Noor, 1986).
© Woodhead Publishing Limited, 2010
696
Materials for energy efficiency and thermal comfort in buildings
Traditional floor heating in Korea, China and Afghanistan The traditional floor heating system is known in Afghanistan as Taba kana and in Korea as Ondol. Figure 27.1 presents pictures of a full-scale model of the system, which were taken by the author while attending the 5th International ENERGEX Conference in Seoul, Korea, 1993. The system is based on utilising the heat produced from burning fuel for cooking, such as wood, to heat the living space of the house. An oven is dug in the kitchen floor with three holes. One hole, which is the largest, is used to fire the oven and support the cooking tools. Another hole functions as an inlet for supplying air to the oven. A third hole is connected to a set of ducts running under the floor of the living room, which ends in an exhaust at the other end of the house. Air in the oven which is heated by the burning wood, seeps through the underfloor duct where it is then exhausted to the outside. In the process, the exhausted hot air is replaced by fresher air from the kitchen, which is attached to the other rooms in the house. In this way, the living space is heated by radiation from the floor.
27.5
Applications of design and passive technologies in modern buildings
27.5.1 Introduction Learning from the past for building the present with the future in mind is a strategy which applies to almost every aspect of life, and architecture is no exception. A review of modern architectural attempts to learn from
27.1 Ondol system.
© Woodhead Publishing Limited, 2010
Application of design and passive technologies for thermal
697
‘vernacular’ building techniques and adapt them in today’s urban development has shown an excellent collection of ideas which have been applied worldwide. World collection of modern passive buildings also includes highly inventive technical solutions.
27.5.2 Jeddah International Airport, Jeddah, Saudi Arabia This is a huge project which was designed and built to accommodate a large number of pilgrims from the Muslim world every year. The airport occupies an area of 105 km2 (Kurdi, 1983). The most dominant part of the airport is the pilgrims’ terminal which consists of two identical complexes, each having an area of 255 000 m2. The terminal is covered with a suspended tent structure made up of 210 tents which are made of fibreglass material coated with Teflon. Each tent measures 45 ¥ 45 m and extends up to 10 storeys high from the ground. The tent material is translucent to light and has a white outer surface which helps reflects direct sunlight. The life expectancy of the material is 40 years. A vent is provided at the centre of each tent, thus incorporating 210 roof vents into the whole pilgrims’ terminal. Jeddah’s climate has a hot and humid summer during which air movement and shade are essential factors for inducing thermal comfort. Due to the heavy use of the building, however, a mechanical cooling system is also installed.
27.5.3 Centre for Energy Studies, New Delhi, India This is an office building built within the Indian Institute of Technology complex in New Delhi (Muthu et al., 1991). The climate of the site of this project requires both summer cooling (maximum ambient temperature 40.5 °C, minimum winter ambient temperature 7.3 °C) and winter heating. A dominant feature in this project is the use of domed and vaulted roofs and local simple materials such as mud. The lower parts of the building were built from burnt clay bricks as a precaution against dampness. The upper parts, domed structures, were built from soil blocks, stabilised with 6% cement, moulded by mechanical manually operated moulds while the vaulted structures were built from soil blocks which were stabilised with 4% cement moulded by hand employing wooden moulds. The project also incorporates an earth-air tunnel system about 100 m in length, 0.15 m in diameter and buried at a depth of 3.2 m. Mechanical fans are used to assist in drawing air through the tunnel where it is exposed to a ground mean annual temperature of 25 °C. Ventilation through the building is also enhanced by provision of roof vents under the skylights at the top of each dome. Improving the building’s thermal performance is achieved by a number of other measures. These include reducing solar heat gain in summer by applying small surface area to volume ratio and the use of animal dung on the external surfaces.
© Woodhead Publishing Limited, 2010
698
Materials for energy efficiency and thermal comfort in buildings
27.5.4 University guest house, Jodhpur, India The city of Jodhpur is located at the edge of the great Indian desert. It has hot dry summers and mild winters. Summer can be severe with hot dusty wind. This project was architecturally designed by Vinod Gupta and its energy performance simulation was carried out by Narenda Bansal (Bansal et al., 1994). The project is built on two floors using heavy materials. Most windows are facing north and south with appropriate shading to allow for summer shading and winter direct gain heating. The building also incorporates evaporative cooling towers with wet pads. Roofs are constructed from heavy materials with insulation to reduce solar heat gain in summer.
27.5.5 Patoka Interpretative Nature Centre, Indiana, USA This is mainly a direct gain building designed by Fuller Moore (Moore, 1993). The building incorporates a south facing double glazing inclined at 60°. The northern side incorporates a reflective ceiling which reflects direct sunlight downwards to indoor thermal mass. The thermal storage is provided by a solid tiled floor and fibreglass water storage tubes. The double glazing on the south face has an airspace 10 cm wide, which in winter nights and summer hot days, is filled with polystyrene beads. The beads are blown in the glazing cavity by vacuum motors linked to tanks on the north slope.
27.5.6 Baer residence, New Mexico, USA One feature of this residence, designed by Steve Baer, is the use of water as a heat storage medium which is kept in recycled 55 gallon oil drums. It is claimed that water temperature in the drums remained below boiling point and gave about 60–70% efficiency in winter (Anderson and Riordan 1976). The water-filled drums are painted black on the outside and white on the inside to improve daylight and give a pleasant visual effect. They are stacked behind double glazing facing south which is insulated during the night by movable bottom-hinged insulation panels. The panels, each weighing about 75 kg, are operated into vertical or horizontal positions by hand crank and nylon rope. The panels have a reflective aluminium surface for reflecting direct sunlight onto the water wall in winter, thus adding about 50% of extra energy to the water wall (Moore, 1993). Heat absorbed by the drum material from solar radiation is transferred into the water by conduction and natural convection and to the indoor space by convection and radiation.
© Woodhead Publishing Limited, 2010
Application of design and passive technologies for thermal
27.6
699
Thermal performance of passive solar systems
An important aspect of designing a passive thermal control system is the formulation and simulation of its thermal performance. Defining the variables involved in the heat and airflow transfer through the system would facilitate optimisation of such variables and the efficiency of the system as a whole. Performance of a typical passive system should ideally be assessed as a function of time due to the transient nature of the outdoor thermal conditions. This, however, is a lengthy procedure which involves a considerable number of complex mathematical formulae and it is therefore better performed through specifically written computer programs. There is a wide range of passive thermal control strategies employed worldwide. A simple example of these systems is the mass wall that is usually used as a passive heating strategy which incorporates an opaque wall that is painted black on the outside and covered with glazing (Fig. 27.2). As the dark wall surface is exposed to solar radiation, it is consequently heated. Heat absorbed is then conducted through the wall and transferred to the indoor space by convection and radiation. At steady state, heat delivered into the room during sunshine hours, (Qin, W/ m2) is expressed as (Sodha et al., 1986): Qin = U T (Tsol – TR ) Aw
27.2 Mass wall.
© Woodhead Publishing Limited, 2010
27.1
700
Materials for energy efficiency and thermal comfort in buildings
k U T = ÈÍ 1 + w + 1 ˘˙ h L hi ˚ w Î o
–1
27.2
Tsol = a S + Tam ho where UT = Tsol = TR = S = a = ho
=
hi LW kW Tam Aw
= = = = =
27.3
total heat transfer coefficient, W/m2 · K sol-air temperature, °C room air temperature, °C solar radiation normal to surface, W/m2 absorbtivity of the wall surface to solar radiation, dimensionless, 0.9 overall heat transfer coefficient from irradiated wall surface to the ambient (5.8–20.0 W/m2 · K) depending on wind speed and surroundings heat transfer coefficient from inner wall surface, 0.5 W/m2 · K wall thickness, m thermal conductivity of wall material, W/m · K ambient temperature, °C area of the storage-wall outer surface, m2.
Heat loss in the absence of solar gain (Qout, W/m2) is expressed as: Qout = U T (TR – Tam ) Aw
27.4
Efficiency of the system (h) with respect to heat delivered to indoor space at room temperature (TR) is given by:
h=
Qin S
27.5
If the opaque wall is replaced by a water wall, the same relationships can still be applied except for the total heat transfer coefficient (UT) which should include two new convective heat transfer coefficients for the water (hw1, hw2) to replace the thermal resistance for the opaque wall (L/k). The total heat transfer coefficient for the water system becomes (Uwa): U wa = ÈÍ 1 + 1 + 1 + 1 ˘˙ Îho hw1 hw2 hi ˚
–1
where hw1 = heat transfer coefficient from collector to water hw2 = heat transfer coefficient from water to inner wall surface.
© Woodhead Publishing Limited, 2010
27.6
Application of design and passive technologies for thermal
701
In case the system glazing is extended to produce a solarium, the following relationship can be used (Sodha et al., 1986): Qin È h = U TS Íat S + o Aw h h m m Î hm = ÈÍ 1 + 1 ˘˙ Îho hf ˚
˘ hm ˆ Ê ÁË1 – h ˜¯ Tam – TR ˙ f ˚
27.7
–1
L U TS = ÈÍ 1 + w + 1 ˘˙ h kw hi ˚ m Î
27.8 –1
27.9
where UTS = total heat transfer coefficient for the solarium, W/m2 · k hf = heat transfer coefficient from the outer wall surface to the solarium, 2.8 W/m2 · K t = glazing transmittance to solar radiation, dimensionless, 0.8. Equation 27.8 can, however, be simplified as hm = ho + hf. If the mass wall has upper and lower vents (Trombe wall), then air heated by solar energy collected at the wall surface would rise and result in a current along the Trombe wall duct and through the room (Fig. 27.3). A procedure for predicting the rate of heat transfer to the room was
27.3 Trombe wall with vents.
© Woodhead Publishing Limited, 2010
702
Materials for energy efficiency and thermal comfort in buildings
proposed by Bansal and Thomas (1991) which starts by introducing the following formula: Qin = aS – ho(Tsout – Tam) = net heat absorbed by the wall, W/m2
27.10
According to Bansal and Thomas, steady state heat flow balance implies that the rate of heat absorbed by the wall is equal to the rate of heat convected to the room through the air duct plus the rate of heat conducted through the wall. It is also equal to the rate of heat convected through the air duct plus the rate of heat convected from the inner wall surface: Êk ˆ Qin = mC mCp (TA – TB) + Á w (T T – Tsin )˜ Ë Lw sout ¯
27.11
Qin = mCp(Ta – TB) + (Tsin – TR)
27.12
From Eqs 27.10–27.12 and assuming TB ª TR, Bansal and Thomas derived Eq. (27.13). Qin È ÊL ˆ˘ = U (T – TR ) + m(T m TA – TR ) Á w + 1 ˜ ˙ Ë kw hi ¯ ˚ Aw ÍÎ T sol Vvel = FR
2gh(T TA – TR ) TR
27.14
m = rAaVvel
27.15
È Ê hˆ Ê hˆ ˘ TA = TR exp Á – ˜ + Twso Í1 – exp Á – ˜ ˙ Ë z¯ Ë z¯ ˚ Î
27.16
z=
mCp hoWw
27.17
where Vvel = m = Ta = TB = Cp = Ww = FR = h g
27.13
air velocity in the Trombe wall duct, m/s mass flow rate in the Trombe wall duct, kg/s air temperature at upper vent of the Trombe wall, °C air temperature at bottom vent of the Trombe wall, °C specific heat capacity of air, 1.0 kJ/kg width of wall, m friction factor due to resistance of air flow caused by geometry of the duct and its vents, dimensionless (ª 0.5) = height of air duct (vertical distance between centres of vents), m = acceleration due to gravity, 9.8 m/s2
© Woodhead Publishing Limited, 2010
Application of design and passive technologies for thermal
703
Tsin = temperature of the inner wall surface (in the room), °C Tsout = temperature of outer wall surface (collecting surface), °C. The Trombe wall discussed here is sometimes modified to be used as a summer ventilation system, in which case it functions as a solar chimney (Fig. 27.4). A main difference from its winter use is that the heated air in its duct is not circulated into the room but instead exhausted to the outside. The systems discussed so far can also be incorporated in a pitched roof. if b is the roof angle with the horizontal, then the volume flow rate, Qout, m3/s, through the outlet of the heated air duct can be expressed through the following formulae (Bansal et al., 1993):
Qout =
Cd Aout
2gh (T Tout – TR ) sin b TR ÊA ˆ 1 – Á out ˜ Ë Ain ¯
2
Tout = a + b.exp (– kL) a=
[at S + U t Tam + U bTR ] Ut + Ub + Ul
27.4 Wall solar chimney.
© Woodhead Publishing Limited, 2010
27.18
27.19 27.20
704
Materials for energy efficiency and thermal comfort in buildings
b=
– [at S + U t (TR – Tam )] Ut + Ub + Ul
È1 – exp (k · L )˘ U l = hf Í ˙˚ k ·L Î where K = L = Aout = Ain = Tout = Tin = Cd = hf = Ub = Ut = a = t =
27.21 27.22
conductivity thickness area of air duct outlet, m2 area of air duct inlet, m2 outlet temperature, °C inlet temperature, °C discharge coefficient, dimensionless, 0.6 heat transfer coefficient, given by Bansal et al. as 15 W/m2 · c heat loss coefficient at bottom of air duct, 0.5 W/m2 · c heat loss coefficient at top of air duct, 5.0 W/m2 · c absorptance of collector plate to solar radiation, 0.9 transmittance of glazing to solar radiation, 0.8.
Bansal et al. (1993) used the above formulae to simulate the performance of a solar chimney (0.15 ¥ 1.5 ¥ 1.5 m, b = 30°) integrated in the roof of a room (4 ¥ 4 ¥ 4 m) under ambient temperature (24–36 °C) and solar radiation (0–1100 W/m2). The effect of variation in the ambient temperature on the calculated volume flow rate was only visible at low solar radiation. Assuming 0.6 discharge coefficient, it varied from about 150 to 170 m3/h under 100 W/m2. As the solar radiation increased to 1000 W/m2 , the variation in the volume flow rate reduced to about 10 m3/h with the highest flow rate being 350 m3/h. The predicted air change rate varied from 3 to 6 Ac/h. Ventilation requirements of an occupied space, particularly in hot regions, cannot always be met by thermally induced airflow alone. Wind is another driving force for natural ventilation through building vents. The volume flow rate due to wind action (Qwind, m3/s) is expressed as a function of difference in wind pressure coefficient across the vent: Qwind = Cd AVrref efvel DCP efve
27.23
where Vrefvel = velocity measured at a reference point outside the building, m/s.
27.7
Conclusions
Evidence presented throughout this chapter has highlighted a number of facts regarding human thermal comfort in different regions. Seasonal variations
© Woodhead Publishing Limited, 2010
Application of design and passive technologies for thermal
705
in comfort temperatures do exist and are even permitted by the well-known ASHRAE standard. Significant energy saving in terms of reduction in the overheating period was found to be possible by allowing for occupants’ movement within a space in search for comfort. An interesting conclusion that can be drawn from this chapter is that people in tropical regions and at different times developed various architectural ideas which stemmed from their survival as well as comfort requirements. This actually generates a question. As another generation with obvious differences in both thinking and living standards, should we also develop or add our own ideas? If so, then how much should our ideas be related to the past? If our ideas could meet our survival and comfort needs, then could they be completely different? Before attempting to answer these questions, it would be wise to study some characteristic examples of modern architectural solutions. From the discussion presented, it could also be concluded that the courtyard, especially with the square plan, is ideally more suited to regions with mainly cooling requirements (hot dry). In regions where both cooling and heating are required, each for a significant period, then application of the courtyard becomes questionable. This is perhaps why some residents of such regions decided to block their existing open courtyards or replace them with completely covered living spaces. This chapter also presented a useful review and study of modern research and application of passive thermal solutions such as those applied at town planning level and individual building designs and construction. Consideration of environmental elements in town planning tends to make the thermal designer’s job much easier and successful. Proper street planning means allowing for adequate daylight into surrounding buildings. It also requires careful calculation of solar position, especially during summer and winter.
27.8
Sources of further information and advice
Goulding, J., Lewis, J.O. and Steemers, T.C. (1994), Energy and Architecture. The European Passive Solar Handbook. Batsford, London. Hastings, R. (1999), Solar Air Systems. Built Examples. James & James, London. Hyde, R. (2006), Climate Responsive Design. A study of buildings in moderate and hot humid climates. E&FN SPON, London & New York. Szokolay, S. (2004), Introduction to Architectural Science: The Basis of Sustainable Design. Elsevier, Amsterdam. Wines, J. (1999), Green Architecture, Taschen, Berlin.
© Woodhead Publishing Limited, 2010
706
27.9
Materials for energy efficiency and thermal comfort in buildings
References and further reading
Al-Azzawi, S. (1992), ‘Does every courtyard perform well climatically? Physical characteristics, orientation and building materials. Design of domestic courtyards in hot-dry climates’, Proc. 2nd World Renewable Energy Congress, Reading, UK, Pergamon, London. Anderson, B. and Riordan, M. (1976), The Solar Home Book, Heating, Cooling and Designing with the Sun, Cheshire Books, USA. Asfour, O. S. and Gadi, M. B. (2007a), ‘A comparison between CFD and network models for predicting wind-driven ventilation in buildings, Building and Environment, 42, 4079–4085. Asfour, O. S. and Gadi, M. B. (2007b), ‘Effect of integrating wind catchers with curved roofs on natural ventilation performance in buildings’, Journal of Architectural Engineering and Design Management, 1, 289–304. Asfour, O. S. and Gadi, M. B. (2007c), ‘Using CFD to investigate ventilation characteristics of dome as a wind-inducing device in buildings’, International Journal of Green Energy, 4, 571–588. Awbi, H. B. and Gan, G. (1992), ‘Simulation of solar-induced ventilation’, Proc. 2nd World Renewable Energy Congress, Pergamon, London. Baillie, A. P., Griffiths, I. D. and Huber, J. W. (1987), ‘Thermal Comfort Assessment’, Report ETSU-S-1177, Dept. of Psychology, University of Surrey. Bansal, N. K. and Thomas, P. C. (1991), ‘A simple procedure for selection and sizing of indirect passive solar heating systems’, Building and Environment, 26(4), 381–387. Bansal, N. K., Mathur, R. and Handari, M. S. (1993), ‘Solar chimney for enhanced stack ventilation’, Building and Environment, 28(3), 373–377. Bansal, N. K., Hauser, G. and Minke, G. (1994), Passive Building Design, a Handbook of Natural Climatic Control, Elsevier Science BV, Amsterdam. Baroum, A. H. (1983), ‘Energy response to vernacular shelter and settlement in continental Morocco, North Africa’, Proc. PLEA Conference, ed. Yannas, S. Barra, O. A. (1979), ‘A theoretical study of laminar free convection in 1-D solar induced flows’, Solar Energy, 23, 211–215. Bouchair, A., Fitzgerald, D. and Tinker, J. A. (1986), ‘Passive solar induced ventilation’, Proc. Alternative Energy Conference, Miami, USA. Bouchair, A., Fitzgerald, D. and Tinker, J. A. (1988), ‘Moving air, using stored solar energy’, Proc. 13th National Passive Solar Conference, Cambridge, MA, USA. Brager, G. S. (1992), ‘Using laboratory-based models to predict comfort in office buildings’, ASHRAE Journal, 34(4), 44–49. Croome, D. J., Gan, G. and Awbi, H. B. (1992), ‘Comfort assessment in a naturally ventilated office’, 2nd World Renewable Energy Conference, Reading, UK, Pergamon, London. Dedear, R. J. and Auliciems, A. (1985), ‘Validation of the predicted mean vote model of thermal comfort in six australian field studies’, ASHRAE Trans., 91(2A), 452–468. Ellis, F. P. (1953), ‘Thermal comfort in warm humid atmosphere. Observations on groups and individuals in Singapore’, J. of Hygiene, 51, 386. Evans, M. (1980), Housing, Climate and Comfort, The Architectural Press, London. Fanger, P. O. (1970), Thermal Comfort, Analysis Applications in Environmental Engineering, McGraw-Hill, New York. Fardeheb, F. (1988), ‘Country Monograph: Algeria’, Proc. 6th PLEA Conference. Farouk, O., Norton, J., Etchells, W., Levaux, J., Cain, A. and Afshar, F. (1973), ‘Climatic
© Woodhead Publishing Limited, 2010
Application of design and passive technologies for thermal
707
study of traditional buildings, Cairo, Egypt’, Third World Studies, Architectural Association School of Architecture, London. Fathy, H. (1973), Architecture for the Poor, University of Chicago Press, pp. 5–12. Fleming, W. S. (1979), ‘Energy conservation: an investigation of thermal comfort alternative’, ASHRAE Trans., 85(2), 813–824. Gadi, M. B. (2000a), ‘Design and simulation of a new energy conscious system, basic concept’, Journal of Applied Energy, 64(1–4), 349–354. Gadi, M. B. (2000b), ‘Design and simulation of a new energy conscious system, CFD and solar simulation’, Journal of Applied Energy. 64(1–4), 251–256. Gadi, M. B. (2000c), ‘Design and simulation of a new energy conscious system, ventilation and thermal performance simulation’, Journal of Applied Energy, 64(1–4), 355–366. Gadi, M. B. (2000d), ‘COMFORT, a new computer program for the prediction and analysis of human thermal comfort’, Journal of Applied Energy, 64(1–4), 315–320. Gadi, M. B. (2000e), ‘New computerised tools for building design in different climates’, International Journal of Ambient Energy, 21(4), 171–178. Gadi, M. B. (2000f), ‘A novel roof-integrated cooling and heating system’, International Journal of Ambient Energy, 21(4), 203–212. Gan, G. and Croome, D. J. (1994), ‘Thermal comfort models based on field measurements’, ASHRAE Trans., 100(1), 782–794. Griffith, I. D. (1990), ‘Thermal Comfort in Buildings with Passive Solar Features’, Report ENS-090-UK, Dept. of Psychology, University of Surrey. Humphreys, M. A. (1973), ‘Classroom temperature, clothing and thermal comfort, a study of secondary school children in summer’, JHIVE, 41, 191–202. Humphreys, M. A. (1975), ‘Field Studies of Thermal Comfort Compared and Applied’, Symposium on Physiological Requirements of Microclimate, Prague. Humphreys, M. A. (1976), ‘Comfortable Indoor Temperatures Related to Outdoor Air Temperature’, UK Department of the Environment, Building Research Establishment: Note No. P.D 117/76. Humphreys, M. A. (1978), ‘Outdoor temperatures and comfort indoors’, J. of Building Research and Practice, March/April. Humphreys, M. A. (1979), ‘The influence of season and ambient temperature on human clothing behaviour’, in Fanger, P.O. et al. (eds), Indoor Climate: Effects on Human Comfort, Performance and Health, Danish Building Research Institute, Copenhagen. Humphreys, M. A. (1981), ‘The dependence of comfortable temperature upon indoor and outdoor climates’, in Cena, C. et al. (eds), Bioengineering , Physiology and Comfort, Elsevier, Amsterdam. Humphreys, M. A. (1992), ‘Thermal comfort requirements, climate and energy’, Proc. 2nd World Renewable Energy Congress, Reading, UK, Pergamon, London. Humphreys, M. A. (1994), ‘An adaptive approach to the thermal comfort of office workers in North West Pakistan’, Proc. 3rd World Renewable Congress, Reading, UK, Pergamon, London. Humphreys, M. A. and Nicol, J. F. (1970), ‘An investigation into thermal comfort of office workers’, JIHVE, 38, 181–189. Hunt, D. R. G. and Steel, M. R. (1979), ‘Domestic Temperatures: An Investigation of Long-term Trends’, BRE Note N163/78. Khafaji, O. M. and Murta, K. H. (1989), ‘Controlled ventilation as a cooling agent in school design for arid tropical areas’, proc. 2nd european conference on architecture, France. © Woodhead Publishing Limited, 2010
708
Materials for energy efficiency and thermal comfort in buildings
Konya, A. (1980), ‘A Design Premier for Hot Climates’, The Architectural Press, New York. Kurdi, T. M. K. (1983), ‘Innovative Low Energy Cooling at the Haj-Terminal, King Abdulaziz International Airport, Jeddah, Saudi Arabia’, Proc. PLEA Conference, ed. Yannas, S., Pergamon, London. McNall, P. E., Pierce, E. T. and Barnett, P. J. (1978), ‘Control strategies for energy conservation’, in Stolwijk, J. A. J. (ed.), Energy Conservation Strategies in Buildings, John Pierce Foundation, New Haven, CT. Mohsen, M. (1979), ‘Solar radiation and courtyard house forms – II. Application of the model’, Building and Environment, 14, 185–201. Moore, F. (1993), Environmental Control Systems, Heating, Cooling and Lighting, McGraw-Hill, Inc., New York. Muthu, R. K., Minke, N. K., Bansal, N. K. and Cook, J. (1991), ‘Construction with low energy materials’, Proc. ISES Solar World Congress, USA, Pergamon, London. Nevins, R. G. and McNall, J. (1973), ‘ASHRAE thermal comfort standards’, Building Research and Practice, March/April. Niles, P. W. B. (1976), ‘Thermal evaluation of a house using a movable-insulation heating and cooling system’, Solar Energy, 18, 413–419. Noor, M. (1984), ‘The function and form of the courtyard house’, Proc. Colloquium, University of Newcastle upon Tyne, CARDO, UK. Oke, T. R. (1988), ‘Street design and urban canopy layer climate’, Energy and Buildings, 11, 103–113. Olgyay, V. (1963), Design with Climate – Bioclimatic Approach to Architectural Regionalism, Princeton University Press. Olgyay, V. (1973), Design with Climate, Princeton University Press. Oseland, N. A. (1994), ‘A comparison of the predicted and reported thermal sensation vote in homes during winter and summer’, Energy and Buildings, 21, 45–54. Schiller, G. E. (1990), ‘A comparison of measured and predicted comfort in office buildings’, ASHRAE Trans., 96(1), 604–622. Schiller, G. E. and Arens, E. A. (1988), ‘Thermal comfort in office buildings’, ASHRAE Journal, October, 28–32. Schiller, G. E., Arens, E. A., Bauman, F. S., Benton, C., Fountain, M. and Doherty, T. (1988), ‘A field study of thermal environments and comfort in office buildings,’ Center for the Built Environment, U.C. Berkeley. Sharma, M. R. and Sharafat, A. (1986), ‘Tropical summer index – a study of thermal comfort of Indian subjects’, Building and Environment, 21(1) 11–24. Sodha, M. S. Bansal, N. K., Bansal, P. K., Kumar, A. and Malik, M. A. S. (1986), Solar Passive Buildings, Science and Design, Pergamon Press, London. Tsapos, C. (1992), ‘Acceptance of passive solar buildings by the end-user’, Proc. 2nd World Renewable Energy Congress, Reading, UK, Pergamon, London. Zmeureanu, R. and Doramajan, A. (1992), ‘Thermally acceptable temperature drifts can reduce the energy consumption for cooling in office buildings’, Building and Environment, 27(4), 469–481.
© Woodhead Publishing Limited, 2010
Index
absorbent, 116, 520 absorption, 116, 365 absorptivity, 488 ACDP see Advisory Committee on Dangerous Pathogens acetic acid, 157 acrolein, 154 activated alumina, 372 activated carbons, 414 active conditioning systems, 523 active nucleants, 260 adaptive model, 142, 684 adhesion, 30 adiabatic system, 5 adsorbents, 116 liquid, 372 solid, 372 adsorption, 116, 365 advanced building façades application in practice, 495–9 commercial refurbishment, 497, 498–9 demand reshaping measures progressive deployment, 500 embedded RE systems in The Lighthouse Building, 501 Lighthouse Building in Glasgow, 498 solar façade at University of Strathclyde student residences, 497 student residences, 495, 498 benchmarking performance, 499–501 building performance integrated view, 496 component options, 485–6 demand reshaping, 485 energy supply, 485–6 embedded heat flux sensor, 493 integrated performance rating, 494–5 modelling and simulation required parameters, 495 performance assessing and benchmarking, 484–501 performance models and model parameter measurement, 486–94 advanced glazings, 488 ducted wind turbines, 490–3
in situ measurements, 493–4 material properties, 486–8 photovoltaic cells, 489–90 transparent insulation, 488 adventitious leakage, 92–4 effect on a balanced mechanical system, 93 effect on a natural ventilation system, 93 adventitious openings, 84 Advisory Committee on Dangerous Pathogens, 602, 604 aerogel, xx, xxi, 219–21 applications optical applications, 336 solid state insulation, 336 space applications, 336 formation, 325–32 ambient-pressure drying process, 329–31 controlling density and void size distribution, 331–2 drying techniques, 325–6 evaporation of solvent molecules, 326 freeze-drying process, 329 spring back effective gel demonstration, 330 supercritical drying, 326–9 supercritical drying schematic, 327 supercritical drying using carbon dioxide, 328 surface silylating process, 330 future trends, 336–8 covalent bio-conjugation protocols schematic, 338 formation of non-covalent biospecies conjugates schematic, 337 materials for insulation in buildings, 319–39 background, 320–1 general properties, 319–20 physical properties, 332–5 acoustic properties, 336 comparing thermal conductivity with other materials, 333
709 © Woodhead Publishing Limited, 2010
710
Index
model of thermal transportation properties, 332 optical properties, 334–5 principle of energy saving, 334 thermal conductivity, 332–4 processing materials and properties, 321–5 advancement using other alkoxides, 324–5 electrical double layers, 323 metal alkoxides synthesis and structure, 324 silicon-oxygen groups, 324 sol-gel and drying processes scheme, 321 sol-gel processing, 321–3 uncharged nanoparticles, 323 translucent, 336 transparent, 336 Agency for Renewable Raw Materials, 249 AGI Working documents, 295 air conditioning, 104 air entry value, 46 air exchange rate, 155 air fresheners, 162 air leakage, 87, 575 air quality, 85–6, 97 air quality and airtightness ventilation in buildings, 77–98 future trends, 97–8 issues concerning materials, 92–7 natural ventilation design, 90–2 natural ventilation feasibility, 86–90 physical mechanisms, 81–6 ventilation systems, 77–81 airtight membrane, 447 airtightness, xx, 87–8, 92–4, 447–8, 688 albedo, 516 alcogels, 320 aldehydes, 156, 157, 161 aliphatic hydrocarbons, 259 allophone, 412 alumina aerogel, 325 aluminium, 306–7, 309, 409 aluminium nitride, 413 aluminosilicates, 372 ambient-pressure drying, 329–31 American Society for Heating, Refrigeration and Air Conditioning Engineers, 462, 682 detailed algorithm, 15 angular velocity, 491 ANSI/ASHRAE Standard 160-2009, 62–3 Apollo Adhesives, 449 aquagels, 320 Arc Architects, 353 Arndale Shopping Centre, 574 artificial lighting systems, 618 asbestos, 164, 165
friable, 164 non-friable, 164 ASHRAE see American Society for Heating, Refrigeration and Air Conditioning Engineers ASHRAE Handbook – Fundamentals, 15, 461, 463 ASHRAE Standard, 685, 705 ASHRAE Standard 90, 462 ASHVE, 373 Aspen Aerogel, 445 asphalt, 465, 481 solar reflectance and thermal performance of asphalt shingles, 467 asphyxiants, 153 asthma, 158–9 ASTM C 1340, 306 ASTM C 1371, 307 ASTM E06, 63 Attestation of Conformity procedure, 234–5 Austrian Federal Ministry for Transport, Innovation and Technology (BMVIT), 666 auto coherent homogenisation, 349–50 automation, 624–5 bacteria, 164–5 bamboo, 166 barometric pressure, 373 BASF study, 640–1 BASFAG (2006), 640 batch process, 262–3 bathroom pod, 436 installation, 435 batt, 461 Bedford seven-point scales, 129 behavioural scripts, 544 behavioural thermoregulation, 142 BEMS see Building Energy Management System bentonite, 378 BEPAC, 480 BER see Building Emission Rate Bernoulli’s principle, 466, 476, 478 BET, 332 biodiversity, 513 Biosafety in Microbiological and Biomedical Laboratories, 602 Biot number, 12 effect on steady state temperature gradient, 13 effect on temperature gradient evolution, 13 bitumen, 465, 481 black body, 19 blanket, 461 blowing agents, 258–9 BMS see Building Management System
© Woodhead Publishing Limited, 2010
Index BMVIT see Austrian Federal Ministry for Transport, Innovation and Technology boards, 276 Boustead, 181 BRE see Building Research Establishment BRE Trust, 622 BREEAM see Building Research Establishment Environmental Assessment Method British Board of Agrément, 546 British Pavilion, 456 brittleness, 286 BS EN 15026, 58, 61, 65 BS EN ISO 8990, 9 BS EN ISO 12572, 42, 350 BS EN ISO 14020, 178, 179 BS EN ISO 14025, 184 BS EN ISO 14040, 178 BS EN ISO 14040:2006, 183 BS EN ISO 14044:2006, 183 BS ISO 15686-8:2008, 185 buffering, 345 Building Act 1984, 149 Building and Environment, 403 Building Authority Acceptance, 303 Building Bulletin 101, 506, 517 Building Emission Rate, 581 Building Energy Management System, 583, 584 building envelope, 87, 442 primary objective, 442 building equipment, xxi thermal insulation material, 274–303 Building Management System, 90, 619 building materials heat and mass transport processes, 3–47 nomenclature, 50–3 life cycle assessment and environmental profiling, 175–91 environmental labeling, 178–9 LCA of building materials, 179–82 LCA standardisation, 182–7 life cycle approach, 176 materials sustainability, 175–6 other issues, 189–91 UK context, 187–9 building physics, 442 Building Regulations, 581, 633 Building Regulations (1965), 537 Building Regulations Part L2, 567 Building Research Establishment Environmental Assessment Method, 68, 187, 480, 568, 580, 589, 622–3, 645 aims, 622–3 construction, 622 environment, 622 fire and risk in built environment, 622
711
objectives, 623 building science, 442 Building Science Corporation, 442 building tight and ventilating right, 569 bulk density, 60 buoyancy, 81, 518 BUWAL, 182 calcium chloride, 420 calcium silicate foam, 217–18 Cannabis sativa, 244 capillarity, 29, 33–6, 37 capillary conduction, 35 capillary domain, 34 capillary potential, 31, 37 vs relative water content, 36 capillary saturation, 34, 35 capillary suction see capillarity capillary water, 29 capric acid, 386 carbon, 372, 422 carbon aerogels, 324–5 carbon capture storage, 543 carbon composites, 408 carbon dioxide, 258, 328 emissions, 513 carbon fibres, 408, 414–15 structure types, 415 carbon monoxide, 153, 167 Carbon Performance Rating, 567 Carbon Vision Buildings, 541 carboxylic acids, 156 cardigan culture, 524 cars, 511, 512 casting, 265 cavity masonry, 537 cavity wall, 204 CCS see carbon capture storage CCTV surveillance systems, 612 CDC see Centres for Disease Control and Prevention CE mark, 293, 294 CEEQUAL, 187 CEH see Creative Energy Homes cellular concrete, 379 cellular glass, 215–16 cellular-planned offices, 565 cellular wool, 662 cellulose acetate, 259 cellulose fibre, 244, 420–1, 422 air-to-air heat and mass exchanger, 420 Celuka process, 265 CEN Mandate, 187 Centres for Disease Control and Prevention, 602 ceramics, 412–13, 421, 422 fibres, 218–19 structure overview, 413 thermal conductivity, 408
© Woodhead Publishing Limited, 2010
712
Index
cereal granulate, 246, 247 CFD see computational fluid dynamics changeover mixed-mode system, 78 charcoal, 152 Charles Rennie Mackintosh design, 498 Chartered Institution of Building Services Engineers see CIBSE chemical foaming, 260 chemical heat storage, 115–18, 120–1 materials, 120–1 reaction heat storage, 118 sorption heat storage, 115–17 chlorine, 160 4-chloro-3-nitro-benzoic acid, 155 chlorofluorocarbon, 259 chloromethane, 157 chlorotrimethylsilane surface silyating process on aerogel, 330 CHP systems see combined heat and power systems Ciba Chemicals, 449 CIBSE Building Energy Codes, 580 CIBSE Guide A, 563, 564 CIBSE Guide C, 15 CIBSE Guide F, 638 CIBSE recommendation, 569 CIBSE TRY climate files (2005), 544 cladding, 298, 620 Clausis Dictum, 5 Clausius-Clapeyron equation, 114 clay, 351–4, 382, 694 bricks, 227 expanded, 225–7, 662 expanded pellets, 226 light expanded clay aggregate, 225 materials, 351–4 mineral structures composition, 352 plasters, 354 CLAYTEC, 354 cleaning products, 162 climate, 86–7 impact on building fabric, 688–9 glazing, 688 thermal insulation, 688 thermal storage, 688–9 impact on urban pattern and building form and fabric, 685–7 building form, 686–7 roof form, 687 street planning, 686 thermal comfort, 681–5 global criteria, 683–5 influencing parameters, 682 Climate Change Bill, 540, 543, 637 Climate Consultant software, 478 Clo, 133 closed system, 5 coal, 513 coconut fibres, 248, 662
Code for Sustainable Homes, 187, 580, 633, 636, 645 coefficient of diffusivity, 40 coefficient of performance, 95 coefficient of permeability, 36 moisture dependent, 37 cohesion, 30 cold bridging, xx, 519 cold cure, 264 combined heat and power systems, 378, 616 combustion, 151–2 comfort, 441 comfort equation, 133 Comfort Zone Chart, 373 commercial buildings embodied energy, 577–8 embodied pollution, 578 factories and warehouses energy efficiency and thermal comfort, 574–7 environmental design, 575–6 typical construction, 576–7 future trends in design and refurbishment, 583–6 material choice, 578–80 steel vs concrete, 579–80 thermal mass, 579–80 materials for energy efficiency and thermal comfort, 562–86 measured room temperature with additional salt hydrate and without PCM, 585 with and without PCM-plaster, 585 modelling and monitoring thermal performance and comfort, 580–3 fingerprinting, 581–2 SBEM, 580–1 sensors, 582–3 offices energy efficiency and thermal comfort, 563–70 air conditioning and natural ventilation, 568–70 good practice/typical practice, 566–7 journey to work, 567–8 lighting and artificial lighting, 568 main differences from dwellings, 563 situation in offices, 563–6 retail spaces energy efficiency and thermal comfort, 570–4 environmental design, 572 freezer cabinets in supermarkets, 573 lighting and artificial lighting, 571–2 natural ventilation and air conditioning in supermarkets, 573 shopping centres and supermarkets, 571 typical construction, 573–4 compatibility, 408 complementary mixed-mode system, 78
© Woodhead Publishing Limited, 2010
Index Composite Technology Park, 459 composites, 356–7 computational fluid dynamics, 85, 687 computer modelling, 591 concrete, 164, 579 Concrete Centre report, 638 concrete panel, 438–9 condensation interstitial, 104 surface, 104 conservation area, 540 conservation laws law of conservation of energy, 6–7 law of conservation of mass, 6 law of conservation of momentum, 6 conservation of thermal energy equation, 88 constant drying rate, 44 construction moisture, 57 Construction Products Directive, 232, 294 Control of Asbestos Regulations 2006, 164, 165 Control of Substances Hazardous to Health Regulations (1994), 602 Control Volume Method, 14 convection, 14–15 convection coefficient, 15 forced, 16 natural, 15 convection heat transfer, 16 convective heat, 576 cooking energy, 653 cool roofs, 466 cooling, 88–9, 516–17 heat energy storage in buildings, 101–24 fundamentals of thermal energy storage, 106–18 materials for thermal energy storage, 118–22 psychometrics, 102–6 thermal storage applications for building heating and cooling, 122–4 copper, 409 cork, 166, 662 cork-board, 242, 243 COSHH see Control of Substances Hazardous to Health Regulations (1994) cotton, 246, 662 Council Directive 89/106/EEC, 231, 235 CPR see carbon capture storage cradle-to-cradle assessment see life cycle assessment cradle-to-grave assessment see life cycle assessment Creative Energy Homes, 669 Criteria for Moisture-Control Design Analysis in Buildings, 62 cryogel, 320 CTP see Composite Technology Park
713
cubic lattice and capillary bridge model, 350 CVM, 26 d-limonene, 162 DALI control gear, 611 Dalton’s Law of Partial Pressures, 27, 373, 374 dampness control, 360 Darcy’s law, 35, 36, 38 expression for mean flow of velocity, 38 Davison Microtraps, 414 daylight, 514–15 daylight compensation lighting, 618–19 Daylight-Europe project, 494 DEC see Display Energy Certificate decarbonising, 513 declared value, 287–93 fire behaviour, 291 maximum service temperature, 292 thermal conductivity, 288–90 water vapour diffusion, 293 DEFRA see Department for Environment, Food and Rural Affairs density, 266 Department for Environment, Food and Rural Affairs, 603–4 deposition velocity, 155, 156 desiccant, xxii, 520 air humidity system summer psychrometrics, 376 typical psychrometrics, 375 winter psychrometrics, 377 air quality, 369–70 applications, 367 cycle, 366–7 desiccant cycle schematic, 366 EER and COP, 382–3 evaporative cooling method, 105 health and comfort, 367–9 heat loss by clothed sedentary person, 368 influence of humidity on comfort, 369 influence of moisture on people, 370 lines of comfort, 374 liquid desiccants vs water, 367 moisture control in buildings, 365–83 natural and commercial desiccants, 370–2 absorption and desorption cycle, 380 novel desiccant system, 379 occupant density effect desiccant and humidity levels, 371 dew point and humidity level, 373 performance comparison of typical building materials, 381 practical applications commercial desiccants, 373–8 natural desiccants, 378–82 desorption, 115 desorptivity, 44 Determination of Thermal Transmissivity of a Moist Material, 350
© Woodhead Publishing Limited, 2010
714
Index
Developing Rammed Earth for UK Housing, 354 Development of WHO Guidelines for Indoor Air Quality, 150 dew point, 103, 447 cooling system, 401 temperature, 103 dibenzodioxins, 166 1,3-dichloro-2-propanol, 159 differential scanning calorimetry, 387 diffusivity, 260–1 dimethyl sulfoxide, 624 DIN 4108-10, 205–6 DIN V 4108, 201, 238–9 diode factor, 490 direct evaporative cooling, 399–400 process schematic, 400 discharge coefficient, 84 displacement ventilation, 81 Display Energy Certificate, 583, 635 DMSO see dimethyl sulfoxide domestic buildings architectural vernacular, 540–1 carbon payback time, 546–58 external wall insulation systems with different insulation materials, 551 fabric and occupancy, 550 insulation material properties, 549 other factors, 556–8 wall encompassing an external insulation system, 549 certified external insulation systems in the UK, 547–8 EU domestic housing stock, 534 dwellings in some EU countries disaggregated by location and construction age, 535 total dwellings in EU27 disaggregated by country, 534 external wall insulation, 545–6 market statistics, 545–6 number of solid wall dwellings disaggregated by rogers societal groupings, 546 system types, 546 fabric heat loss and CO2 emissions, 537–40 dwellings of solid wall construction, 539 heat loss through the external wall, 539 in-situ measurement of solid walls, 537 wall construction and insulation level effect, 538 household willingness to pay, 554–5 household income level of respondents disaggregated by level of interest, 557 innovator class disaggregated by income level, 557
respondent perception to the effect of energy efficiency measures, 558 respondents interested in purchasing energy saving technological interventions, 556 internal wall insulation, 543–5 intervention strategies, 541–3 CO2 savings of detached solid wall dwelling, 542 deep cut technological intervention sets, 542 materials for energy efficiency and thermal comfort, 533–59 UK domestic housing, 534–7 disaggregated by construction age and type of dwelling, 536 stock, 536–7 whole life cycle costing, 550–4 annual gas tariff increase effect on external wall insulation discounted cost of investment, 552 caveat 1, 553 caveat 2, 553–4 caveat 3, 554 learning rates for a range of different technologies, 554 major assumptions used in WLC calculation, 552 double-Likert scale, 581 draught rating, 140 model, 140 dry air, 102 dry-bulb temperature, 103 dry cup test, 43 DSC see differential scanning calorimetry DSM see Dynamic Simulation Model ducted wind turbines, 485, 490–3, 499 façade-integrated DWT, 491 monitored power output and CP value, 492 Dupont Energain, 123 durability, 408 dust, 164 dust mite, 165 dynamic insulation, 96–7 Dynamic Simulation Model, 635 DYNBIL, 642 EC Biological Agents Directive (2000/54/EC), 602 ECG019, 566–7 eco-balance, 208, 240 eco-building design, xxii advanced building materials, 505–31 comfort and health in buildings, 506–8 health, 507–8 light, 507 sound, 507 the brief, 506 thermal comfort, 506–7
© Woodhead Publishing Limited, 2010
Index future trends, 526, 529–31 brief for new materials, 529 drivers for more sustainable buildings, 526, 529 dynamic materials, 529–30 living world, 530 plants in buildings, 531 Heelis annual working hours where temperatures exceed various thresholds, 527 brief case history, 523–5 daylight in mezzanine, 526 ground floor fresh air intake, 528 roof construction, 525 roof vent internal view, 528 sun path and air flow, 524 issues, 506–13 buildings and external environment, 511–12 energy efficiency in buildings, 509–11 food and water, 511 materials and waste, 508–9 renewable energy variability, 510–11 process, 520–3 climate and site conditions, 522 design, 522–3 documentation and delivery, 523 environmental control standards and maintenance, 520 fitting into the existing urban fabric, 520–2 sustainable development challenges for a designer, 513–20 cold bridging on aluminium frame and poor air circulation, 519 cooling, 516–17 energy usage in buildings, 520 environmental control in a building, 513–14 growth area in energy use, 521 heating, 515 internal moisture and pollutant control, 518–20 light and daylight, 514–15 lower heating energy consumptions in newer buildings, 521 stopping things going in or out of a window, 518 thermal storage, 516 ventilation, 517–18 use of space, 512–13 climate change, 512 investment in new vs existing buildings, 513 social equity, 513 eco-roofs, 467–9 Ecoinvent, 181 ECON19, 566–7
715
ECOTECT, 26, 523, 580 Ecoterre bricks, 353 EER see energy efficiency ratio effective emittance, 310 effective temperature index, 132 efflorescence, 36 EH75/1, 165 electrical energy, 510 embodied energy, 655 EMC see Environmental Profiles Methodology emissivity longwave, 493 opaque surface, 488 surface, 494 EN 12086:1997, 286 EN 12667:2001, 282 EN 12939:2000, 282 EN 13162, 214 EN 13172, 293, 295 EN 13172:2008, 288 EN 13238:2001, 283 EN 13469:2001, 286 EN 13501, 283 EN 13787:2008, 288 EN 13823, 284, 301 EN 13823:2002, 283 EN 14114, 298 EN 14706:2005, 285 EN 15715, 283, 285 EN 13501-1, 201, 283 EN 14707+A1:2007, 285 EN ISO 1182:2002, 283 EN ISO 1716:2002, 283 EN ISO 8497, 300 EN ISO 8497:1996, 283 EN ISO 15148, 39 EN ISO 17011, 295 EN ISO 17025, 294 EN ISO 23993, 275, 300 EN ISO 11925-2:2002, 283 energy, 4 energy balance, 58 energy consumption, xix, 652 by end use in EU, 652 in residential buildings, 653 operational, xxi, typical patterns, 567 world market, 651 Energy Consumption Guide 19, 566 energy efficiency, xx, xxii, xxiii breakdown of energy for major end uses in Australia, 653 energy consumption by end use in EU, 652 residential buildings, 653 world market, 651 materials for domestic buildings, 533–59 materials for high performance buildings, 589–625
© Woodhead Publishing Limited, 2010
716
Index
materials for new buildings, 631–47 materials for the refurbishment of existing buildings, 649–77 total primary energy use world-wide, 650 energy efficiency ratio, 382–3 energy labeling system, 663 Energy Performance Certificate, 581, 613, 635 Energy Performance of Building Regulations, 635 Energy Performance of Buildings Directives, 581 Energy Plus, 473, 523, 580 Energy Savings Directive, 194, 303 energy wasters, 562 enthalpy, 5, 103 atmospheric air, 103 buffering, 346, 348–9 entropy, 5, 107 envelope flows, 81–2 Envest, 188–9 Environmental Agency, 578 Environmental Change Institute for Building Market Transformation research project, 538 environmental health and safety combustion, fire and combustible materials, 151–5 deposition velocities of gases, 156 in buildings, 148–68 indoor emissions and outgassing, 157–61 fabrics and coverings, 158–9 flame retardants, 159–60 floors, 157 formaldehyde occupational and environmental concentrations, 160 paints, solvents and preservatives, 158 plastics, foams and glues, 160–1 secondary production, 161 wood, 157 materials and toxicity, 165–6 regulation, 165–6 occupant activity, 161–3 cleaning and fragrances, 162 cooking, 161–2 ozone generation, 162–3 outdoor pollutants infiltration, 155–7 particles in buildings, 164–5 non-viable particles, 164 spores and bacteria, 164–5 potential limits to exposure from toxic gases, 154 recommended air change rates, 152 safety issues in occupied spaces, 150–1 transformations within the interior, 163 environmental labelling, 178–9 framework and declaration, 179 Environmental Management – life cycle assessment, 178 Environmental Management Systems, 611
environmental product declaration, 210 Environmental Profiles Methodology, 188 weighting factors, 182 environmental profiling, xxi and life cycle assessment of building materials, 175–91 environmental labelling, 178–9 life cycle approach, 176 materials sustainability, 175–6 other issues, 189–91 UK context, 187–9 environmental temperature node, 22 E.ON 2016 Research House, 669, 672 EPBD see Energy Performance of Buildings Directives; EU Energy Performance of Buildings Directive EPC see Energy Performance Certificate epoxy resin, 621 equilibrium moisture content, 31, 370 equivalent clothing index, 142–4, 145 equivalent resistance, 9 Errol Brick Company, 353 Essential Requirement 3, 210, 240 ESTI Test Specification Number 503, 489 estimated service life, 185 ETH-ESU, 182 ETICS, 214 EU Commission Mandate 350, 210 EU Directive 89/106/EEC, 294 EU Directive 89/677/EEC, 166 EU Energy Performance of Buildings Directive, 583, 634–5 EuroACE, 658 European Commission Joint Research Centre: Institute for Environment and Sustainability, 182 European Committee for Standardisation, 187, 232 European Construction Products Directive, 197 European Energy Performance of Buildings Directive, 193 European heat-wave 2003, 167 European Organisation for Technical Approvals, 235 European Recoverable Carrier, 336 European Technical Approvals, 197, 232, 233, 235 evapo-transpiration, 467 evaporative cooling systems, xxii, 89–90 application of porous materials in buildings, 417–22 assessing the capacities and associated requirements in materials, 404–9 direct and indirect systems using porous materials in buildings, 399–423 nomenclature, 426 direct evaporative cooling process schematic, 400
© Woodhead Publishing Limited, 2010
Index heat and moisture transfer indication in an indirect evaporative cooling system, 404 psychrometric diagram, 404 indirect evaporative cooling process schematic, 400 materials used, 402–3 potential materials comparative analyses, 409–17 carbon, 414–15 carbon fibre structures, 415 ceramic structure overview, 413 ceramics, 412–13 comparing the materials, 415–17 fibre, 411–12 hardwood fibre structure, 411 heat exchanging copper tube, 409 heat pipe with metal wick, 421 metal, 409–11 metal foams, 410 metal wools, 411 properties selected material types, 416 zeolites, 413–14 thermal conductivity fibres, 407 metals and alloys, 407 porosity of carbon fibres and carbon composites, 408 various ceramics, 408 types, 399–402 direct evaporative cooling, 399–400 indirect evaporative cooling, 400–2 evaporator, 104 existing buildings, refurbishment, 649–77 exothermal sorption, 105 extensive roof gardens, 467–9 external wall insulation systems, 558 carbon payback time, 559 retrofit, 553 extrusion, 263–4, 265 factories energy efficiency and thermal comfort, 574–7 environmental design, 575–6 collection of heat for warm-air system and radiant heating system, 576 heating requirement and systems, 576 lighting and daylight control, 575–6 typical construction, 576–7 falling drying rate, 45 fan energy, 80 Fanger comfort theory, 683 Fanger heat balance equation, 134 Fanger model, 684 Fanger Predicted Mean Vote model, 683 far stream, 45 fatty acids, 386–7 FDA see Food and Drug Administration
717
felts, 276 fibre, 423 hardwood structure, 411 transparent, 688 see also specific fibre fibre composite materials insulation in buildings, 229–55 fibreboards, 160 fibreglass, 461 Fick’s law equation, 40 Fick’s law of diffusion, 40, 43 Fife, 353 filigrane, 325 fingerprinting, 581–2 deep-plan, modern, naturally-ventilated building, 583 deep-plan office with atrium and underfloor air conditioning, 582 double-Likert scale for building performance criterion, 582 finishes, 166 flammability, 268–9 flax, 246, 247 fibres, 412 floor insulation, 206 flooring, 157, 620–1 flow rate, 83 FLUENT, 14, 26 foamed glass, 216–17 foaming mechanism, 259–62 Food and Drug Administration, 599 Ford Motor, 470, 474 Forest Stewardship Council, 190 formaldehyde, 160, 161, 165 occupational and environmental concentrations, 160 vapour, 603 formic acid, 157 Fourier number, 14 Fourier’s equation, 487 Fourier’s Law of Thermal Conduction, 8 fractional effective dose, 154 fragrances, 162 Franklin, 182 Fraunhofer façade test building, 642 Fraunhofer Institut, 642 Fraunhofer Institute for Building Physics, 65, 357 free cooling, 123 freeze-drying, 329 freezer cabinets, 573 fume cupboards, 610 furans, 166 furfural, 157 GaBi, 181 gas cooking, 153 GEF see grid emission factor gel, 320
© Woodhead Publishing Limited, 2010
718
Index
generic WLC equation, 551 German Environmental Survey, 151 German Hazardous Substances Ordinances, 214 German Institute for Building Technology, 221 Gibbs function, 112 vs temperature curve under constant pressure, 113 Glaser Method steady state temperature gradients in a composite wall, 21 Glasgow Herald building, 498 glass, 508, 688 glass fibre, 662 glass reinforced panel, 434 glass wool, 211–12 glazing, 688 materials, 488 global climate change, 661 GLP see good laboratory practice glue, 160 GMP see good manufacturing practice good laboratory practice, 589, 590 good manufacturing practice, 589, 590, 600 granite, 694 gravitational water, 29, 34 Great Pyramids, 694 green bricks, 352 Green Guide to Specification, 188 green roof systems, 467–74, 481 Green wash, 632 GreenTech, 469 grid emission factor, 543 ground source heat pumps, 615, 637 gypsum plaster, 224, 379 HadRM3, 570 Handbook of Environmental Data on Organic Chemicals, 149 hardwoods, 355 harmonised products standards, 197 harmonised standards, 232 heat, 106 heat and mass transport heat transfer: the transport of energy, 7–26 Biot number effect on steady state temperature, 13 Biot number effect on temperature gradient evolution, 13 dry state thermal conduction, 8–10 Glaser’s method for steady state temperature gradients, 21 incident thermal radiation, 19 moisture-dependent thermal conduction, 10–11 nodal network diagram for admittance model, 22, 23 Planck’s isothermal curves, 18
steady state environmental parameters, 20–2 steady state temperature gradient across a material, 8 temperature gradient evolution in a material, 8 thermal convection, 14–18 thermal radiation, 18–20 thermal responses in the admittance model, 24 transient environmental parameters, 22–6 transient thermal conduction, 11–14 Y, U, and f for different fabric design configurations, 25 mass transfer, 26–46 capillarity, 33–6 capillary potential vs relative water content, 36 evaporation and drying, 43–6 Kelvin’s equation and sorption isotherms, 29–33 liquid flow, 36–9 partial immersion test for water absorption apparatus, 39 porous materials, 27–9 psychrometrics, 26–7 sharp wet front analogy for absorption, 38 sorption isotherm with wetting and drying curves, 32 three phase model for porous materials, 28 vapour diffusion, 40–3 water droplet formation, 30 water vapour permeability testing apparatus, 42 processes in building materials, 3–47 conservation laws, 6–7 laws of thermodynamics, 4–5 nomenclature, 50–3 heat balance, 134–5 equation, 134 method, 26 heat capacity, 5, 11 heat energy, 515 heat energy storage cooling in buildings, 101–24 nomenclature, 126 fundamentals of thermal energy storage, 106–18 chemical heat storage, 115–18 energy in substances, 106–7 heat transfer in heat storage systems, 118 latent heat storage, 110–15 sensible heat storage, 107–10 specific heat of water varying with temperature, 108
© Woodhead Publishing Limited, 2010
Index
materials for thermal energy storage, 118–22 chemical heat storage, 120–1 Gibbs functions of two phases around the equilibriium state, 113 heat transfer in heat storage materials, 121–2 latent heat storage, 119–20 phase diagram of a substance, 111 sensible heat storage, 118–19 psychometrics, 102–6 air conditioning principles, 104–6 air conditioning processes on psychometric chart, 105 state of air, 102–4 surface and interstitial condensation, 104 thermal storage applications for building heating and cooling, 122–4 storage media thermal density, 119 structural thermal energy storage materials, 122–3 thermal energy storage incorporated with active cooling/heating, 124 thermal energy storage materials for passive cooling, 123–4 working pairs for heat powered sorption cooling systems, 121 see also thermal energy storage heat flow, 307 rate, 493 heat flow meter apparatus, 10, 315 Heat Flowmeter Output, 10 heat flux, 307 heat flux sensor, 493, 495 heat gains, 617–18 heat loss, xx, 700 heat sink, 616 heat storage, 106 heat storage capacity, 117 heat transfer, 7–26 modes, 16 nodal network diagram for admittance model steady state conditions, 22 transient environmental conditions, 23 heat transfer coefficient, 307 heat flow values downward, 311 horizontal, 312 upward, 312 values for air gaps that exhibit convection, 313 heat transport, 333 heating, 515 ventilating and air-conditioning systems, 459, 541, 569, 651 Heelis annual working hours where temperatures exceed various thresholds, 527
719
brief case history, 523–5 daylight in mezzanine, 526 ground floor fresh air intake, 528 roof construction, 525 roof vent internal view, 528 sun path and air flow, 524 HelioVolt Inc, 474 Hemcrete, 357 Adnams Brewery facility, 358 walls, 358 hemispherical–hemisperical transmittance, 488, 494 hemp, 244 mats, 245 shives, 245 HEPA filtration see high efficiency particulate air filtration herbicides, 512 HEVACOMP, 26 hexamethyldisilazane, 330 high efficiency particulate air filtration, 605 high performance buildings BREEAM, 622–3 aims, 622–3 objectives, 623 clean room environment, 601 complex extract and supply ductwork installation, 606 environmental and energy considerations, 613–22 BMS controls, 619 CHP, 616 daylight compensation lighting, 618–19 external cladding, 620 flooring, 620–1 ground source heat pumps, 615 heat gains reduced by building orientation, 617–18 natural light, 617 natural ventilation, 616 paint systems, 621–2 photovoltaic cells, 619–20 PIR based motion detector/switching to artificial lighting systems, 618 rainwater harvesting, 615 roof lights and light pipes, 619 solar heating, 615 water course/heat sink, 616 wind turbines, 616–17 environmental design and computer modelling, 612–13 external considerations, 595–8 flue stacks as skyline feature of some specialist buildings, 596 future trends, 623–5 internal considerations, 598 laboratory fume cupboard arrangement with adjacent benching, 609
© Woodhead Publishing Limited, 2010
720
Index
materials for energy efficiency and thermal comfort, 589–625 people areas, 612 process areas, 598–612 clean room facilities, 599–602 containment facilities, 602–3 electrical systems considerations, 609–12 mechanical systems considerations, 605–9 other specialist requirements, 603–5 UHTS robotic compound store by REMP, 625 user considerations, 591–5 public/commercial companies, 592–3 quasi-government, 594–5 research and development facility building, 593 research building for UK cancer charity, 595 universities, 593 university laboratory building, 594 high temperature supercritical drying, 326 high throughput screening, 624 Hockerton housing development, 638 hot and tropical climates design and passive technologies application for thermal comfort in buildings, 681–705 hot box apparatus, 314 hot box facility, 313 hot cure, 264 hot-plate method, 486 House of the Future, 666 HTS see high throughput screening human thermal comfort, 441 humidity, 102, 374 absolute, 102 buffering, xx, 347, 359–60 HVAC see heating, ventilating and airconditioning hybrid products, 212–13 hybrid ventilation, 570 hydrated salts, 387 hydrochlorofluorocarbons, 259 hydrofluorocarbons, 259 hydrogel, 320, 322 hydrogen bonding, 29 hydrogen chloride, 155 hydrostatic equation, 82 Hydroton, 226 hygroscopic water, 29, 40 hygrothermal analysis, 345 behaviour and simulation in buildings, 54–75 coinciding temperature and humidity conditions, 68 future trends, 73–5
integral water content of exposed natural stone samples, 69 liquid diffusivity functions of mineral building materials, 61 modelling simultaneous heat and moisture transfer processes, 57–9 temperature and humidity variations, 66 typical simulation result outputs, 64 calculation input data, 59–63 results, 63–5 hygrothermal loads, 55–7 and their alternating directions, 56 model validation and practical applications, 65–73 annual variations and mean profiles of temperature and moisture content, 71 hygrothermal conditions in a flat roof, 65–8 moisture behaviour of natural stone facade, 68–73 moisture distribution in a wall section, 72 models limitations, 73 simulations flow chart, 59 hygrothermal calculation input data, 59–63 results, 63–5 hygrothermal loads, 55–7 and their alternating directions, 56 hygrothermal materials, xxi–xxii applications in buildings and occupied spaces, 358–60 dampness and mould control, 360 humidity buffering and perceived comfort, 359–60 thermal buffering, comfort and energy efficiency, 359 for heat and moisture control in buildings, 345–64 buffering capacities, 346–9 future trends, 360–1 moisture buffer value classification scheme, 348 moisture buffer value experimental data, 348 nomenclature, 363–4 what makes a material hygrothermal, 345–6 functional properties characterisation, 349–51 measurement techniques, 350–1 volume-averaged properties, 349–50 material classes, 351–8 adsorbed water layers surrounding clay particle, 353 clay materials, 351–4
© Woodhead Publishing Limited, 2010
Index
clay mineral structures composition, 352 European spruce timber cellular microstructure images, 356 Hemcrete walls, 358 lime-hemp composite wall cross section, 357 natural fibre materials and composites, 356–7 smart materials, 358 stabilised earth materials, 354–5 stabilised rammed earth house interior, 354 timber, 355–6 hygrothermal simulation, 63–4 flow chart, 59 IAPO see Importation of Animal Pathogens Order (1980) Ibstock, 353 ICE database, 549 ideal moisture buffer value, 348 IDEMAT, 182 IEA see International Energy Agency IEQ see indoor environmental quality IES Virtual Environment, 580 IKTS, 412 immersion process, 387 implicit method, 83 Importation of Animal Pathogens Order (1980), 604 INCA website, 546 indirect evaporative cooling system, 400–2, 418 cooling efficiency, 405 heat and moisture transfer indication, 404 schematic, 400 individually ventilated cages, 604 Indoor Air Pollution, 149 Indoor Air Quality Management Act, 167 indoor environmental quality, 370 infiltration, 84, 87 initial type test, 293 injection moulding, 264–5 ink bottle effect, 31 inorganic mineral materials, xxi individual product files, 211–27 aerogel, 219–21 calcium silicate foam and mineral foam, 217–18 calcium silicate foam boards, 218 cellular glass, 215–16 ceramic fibres, 218–19 exfoliated vermiculite, 224–5 exfoliated vermiculite typical composition, 225 expanded clay, 225–7 expanded clay pellets, 226 expanded perlite, 223–4
721
expanded perlite and insulation boards, 223 foamed glass, 216–17 forms of products supply, 211 glass wool, 212 insulating clay bricks, 227 mineral wool, 211–15 pyrogenic silicic acid and vacuum insulation panels, 221 stone or rock wool, 213 vacuum insulation panels, 222 insulation in buildings, 193–228 application matrix, 205–6 applications of thermal insulation products, 202 building application related properties, 203 building-related properties, 201–7 ecological and health aspects, 207–11 ecological performance, 209 European technical specification standards and approvals, 199 highest thermal transmission coefficient values, 194 individual product profiles, 211–27 insulating materials and products in Germany, 197 mineral materials employed, 196 properties related to acoustic and fire performance, 204 regulatory requirements, 197–200 specific properties based on manufacturer’s declarations, 203 standardised properties, relevant test methods and designations, 200 Institute of Third World Studies (London), 695 insulating materials, 16 individual product profiles, 240, 242–9 cellulose fibres, 244 cereal granulate, 246, 247 coconut fibres, 248 cork-board, 242, 243 cotton, 246 flax, 246, 247 hemp, 244 hemp mats, 245 hemp shives, 245 reeds, 246, 248 sheep’s wool, 245, 246 straw bales, 249, 250 wood chippings, 249 wood fibre, 242, 243 woodwool, 242 woodwool composite boards, 240, 242 natural fibre and fibre composites for insulation in buildings, 229–55 application matrix, 238–9 building application related properties, 236
© Woodhead Publishing Limited, 2010
722
Index
ecological and health aspects, 237, 240 ecological performance based on standardised conditions, 241 European technical specifications, 233 insulating materials and products in Germany, 230 natural organic raw materials, 230 natural organic raw materials forms of product supply, 231 natural organic sources market share, 231 properties related to acoustic and fire performance, 237 regulatory requirements, 231–5 specific properties based on manufactures declaration, 236 standardised properties, relevant test methods and designations, 234 reference buildings, 249–55 kindergarten in Dobeln, 252–3 Passive House in Esslingen, 254–5 Werlte Climate Centre, 250–2 insulation, xxi inorganic mineral materials for buildings, 193–228 building-related properties, 201–7 ecological and health aspects, 207–11 individual product profiles, 211–27 natural fibre and fibre composite materials for buildings, 229–55 building-related properties, 235–7 ecological and health aspects, 237, 240 individual product profiles, 240, 242–9 reference buildings, 249–55 regulatory requirements, 231–5 polymeric foam materials for buildings, 257–69 abbreviations, 272–3 foams classification, materials and foaming mechanism, 258–62 future trends, 269 processing technologies, 262–5 thermoplastic and thermosetting foams, 265–9 reflective materials and radiant barriers for buildings, 305–16 applications and assemblies, 307–9 background and definitions, 305–7 basis for thermal performance, 309–13 calculated thermal resistances for reflective air spaces, 308 codes and standards, 315–16 downward heat flow values, 311 effect of dividing a fixed space, 309 heat flow meter apparatus, 315 heat transfer coefficient values for air gaps, 313
horizontal heat flow values, 312 hot box apparatus, 314 hot box facility to evaluate attic radiant barriers, 316 reflective insulation assemblies, 310 rotatable hot box, 314 thermal performance measurement, 313–15 thermal resistance, 308 units for reflective systems, 307 upward heat flow values, 312 Insulation Contractors Association of America, 462 insulation layer thickness, 302–3 insulation materials fire behaviour, 283 fundamentals, 275–87 applicability and operational temperature range, 279–80 basic materials and structures, 276 forms of supply and dimensions, 276 important properties, 280–7 insulation system properties, 299–301 fire behaviour, 300–1 operational thermal conductivity, 299–300 integrated performance rating, 494–5 integrated performance view, 494 interatomic potential energy, 6 Intergovernmental Panel on Climate Change, 661 Interim Guidance Note, 149 internal air motion, 81 internal heat gains, 90 internal heat transfer coefficient, 301 International ENERGEX Conference, 696 International Energy Agency, 394, 649, 658 International Organisation for Standardisation, 178, 599 LCA standardisation, 183–7 ISO 14025, 184 ISO 14040 series, 183–4 ISO and comparability, 186–7 ISO and LCA in construction, 184–5 interstitial condensation, 447 intrinsic permeability, 37 Ionica building, 478 IPCC see Intergovernmental Panel on Climate Change Isle of Wight, 537 ISO see International Organisation for Standardisation ISO 5, 605 ISO 7, 605 ISO 8, 605 ISO 6946, 311, 312 ISO 7726, 132 ISO 7730, 133, 136, 684
© Woodhead Publishing Limited, 2010
Index
determination of PMV and PPD indices, 138–41 ISO 8301, 9, 350 ISO 8497:1994, 283 ISO 8996, 132 ISO 10051, 10, 350 ISO 10456, 9, 11, 350 ISO 10551, 130 assessing influence of thermal environment, 141 subjective scales, 141 ISO 13787:2003, 290 ISO 14000, 178, 430 ISO 14025, 184, 185 ISO 14040, 184–5 ISO 14644, 600 ISO 15392, 184 ISO 15686, 185 ISO 21930, 184 ISO 21932, 184 ISO 14644 Parts 1 to 8, 599 ISO DIS 28802, 130 ISO DIS 9239-1:2008, 283 ISO TR 9774, 205–6 ISO/TS 21929-1, 184 ISO/TS 21931-1, 184 isolated system, 5 isothermal sorption, 105 IVAM, 182 IVC see individually ventilated cages joules, 4 kaolinite, 352 absorbed water layers surrounding clay particle, 353 Kastell building system, 439 Kelvin equation, 29–33, 58 kerosene, 153 Kirchoff’s law, 19 Knudsen diffusion, 42 Knudsen effect, 333 Knudsen number, 17 Krete, 449 krypton, 336 Kyoto protocol, 654 lamella mats, 282 laminates, 264 large sample stores, 624 latent heat, 114 latent heat storage, 110–15, 119–20 capacity, 114–15 change of phase, 110–11 chemical potential, 111–14 latent heat, 114 materials, 119–20 phase change condition, 111 law of conservation of energy, 6–7
723
law of conservation of mass, 6 law of conservation of momentum, 6 Lawrence Berkeley National Laboratories, 466 Lawrence Livermore National Laboratory, 331 laws of thermodynamics, 4–5 leaching, 265 lead, 165 Leadership in Energy and Environmental Design, 478, 480, 645 leakage, 87 learning investment, 553 LED see light emitting diode LEED see Leadership in Energy and Environmental Design Legionella, 151, 164 life cycle assessment, xxi and environmental profiling of building materials, 175–91 brief history, 177–8 building materials, 179–82 characterisation, 180–1 characterisation example, 180 LCA data/life cycle inventory information, 181–2 methodologies and product category rules, 180 normalisation, 181 weighting, 181 weighting factors, 182 environmental labelling, 178–9 framework and declaration, 179 LCA key principles, 177 life cycle approach, 176 materials sustainability, 175–6 other issues, 189–91 healthy and safe materials, 189–90 resource management, 190 responsible sourcing, 190–1 standardisation, 182–7 European committee for standardisation, 187 inputs and influences on service life planning, 186 ISO, 183–7 suite of related international standards, 185 UK context, 187–9 Envest, 188–9 environmental profiles specification scheme, 189 Green guide to specification, 188 UK BRE environmental profiles methodology, 188 life cycle inventory data, 181–2 light, 514–15 light emitting diode, 610 light pipes, 619
© Woodhead Publishing Limited, 2010
724
Index
light shelf, 514 light steel frame, 434–5 construction example, 436 lighting, 575–6 curfews, 571 lightweight thermal mass, 446 limestone, 694 limonene, 162 Linde Molecular Sieves, 414 linearity rule, 39 linen tow, 662 linoleum, 157, 166, 621 liquid diffusivity, 60 lithium chloride, 371, 375, 420 Living with Risk – Promoting better public space design, 150 LMS see Linde Molecular Sieves local turbulence intensity, 140 loft insulation, 206 London Climate Change Adaptation Strategy, 634 longwave emissivity, 493 loose-fill cellulose insulation, 244 low-profile roofs, 467–9 low temperature supercritical drying, 326 lowest predicted percentage dissatisfied, 136 3Ls principles, 441 LSS see large sample stores LT Method, 580 lumped capacitance method, 12–13 Mark-Houvink-Sakurada equation, 268 mass customisation, 431 mass transfer, 4, 26–46 mass wall, 699 mats, 276 Maxwell relations, 107 mean molecular free path, 41 Mean Vote, 684 Mechanical and Electrical Equipment for Buildings, 465 mechanical ventilation types extract only, 78 supply and extract system, 78 supply only, 78 vs natural ventilation, 78–9 Medicines and Healthcare products Regulatory Agency, 599, 600 Medium Density Fibreboard – Hazard Assessment Document, 165 melting, 111 Merton Rule, 637 mesophase pitch-based fibres, 415 Met, 133 metal, 409–11, 422 thermal conductivity, 407 metal alkoxides, 324
metal foams, 410 metal wick, 409, 423 heat pipes, 421 metal wools, 410, 411 photo, 411 metallic salts, 321–2 MHRA see Medicines and Healthcare products Regulatory Agency M4i see Movement for Innovation micro-combined heat and power systems, 541 microencapsulation, 387 mineral foam, 217–18 mineral insulation products, main applications, 204, 206–7 cavity wall, 204 floor insulation, 206 loft insulation, 206 pipework insulation and ducts, 207 roof insulation, 206 solid wall, 204, 206 mineral wool, 211–15, 279–80, 662 mixed-mode system, 78 mixed mode ventilation, 566, 570 MMC see modern methods of construction Model Energy Code guidelines, 462 modern methods of construction, xxii composite design, 449–50 human factors, 450 knowledge sharing, 450 ultra thin flexible reinforced concrete membrane, 449–50 Kastell building system, 439 offsite construction, 428–30 types, 431–40 PCMs, 445–6 advancements for buildings, 446–8 portable/re-locatable building, 432 prefabricated building units, 427–50 comfort factors in lightweight buildings, 440–1 delivering sustainable comfort, 442–4 design led materials for addressing lightweight performance issues, 441 materials led building design, 427–8 new membrane developments, 448–9 standardisation in construction, 431 thermal mass in offsite potential, 445 thin solutions, 444–5 temperature control, 443–4 volumetric building, 433 moisture, 369 moisture balance, 58 moisture buffer value, 347, 349 classification scheme, 348 experimental data graph, 348 test, 33 moisture control, 54–5 moisture conversion factor, 11 moisture mass, 371
© Woodhead Publishing Limited, 2010
Index moisture storage, 58, 60 function, 31, 351 molecular sieves, 413 monoculture crops, 512 Monsanto Chemical Co., 320 Monte Carlo method, 17 montmorillonite, 352 absorbed water layers surrounding clay particle, 353 Montreal protocol, 259 mould control, 360 Movement for Innovation, 563 mud bricks, 694 n-aldehydes, 156 nano insulation materials, 18 nanoclays, 261 naphthalene, 158 narrow techno-economic calculation, 559 National Atmospheric Emissions Inventory, 508 National Calculation Method, 612 National Human Activity Pattern Survey, 151 National Renewable Energy Laboratory, 394 natural fibre materials, 356–7 for insulation in buildings, 229–55 natural light, 617 natural ventilation, 78, 476–8, 575, 616, 704 characteristics, 83–4 design, 90–2 basic procedures, 90–2 design criteria, 92 ventilation strategy, 91 feasibility, 86–90 airtightness, 87–8 building envelope, 87 climate, 86–7 control, 90 cooling, 88–9 evaporative cooling, 89–90 internal heat gains, 90 occupants, 88 thermal storage, 89 Ionica Building and RWE Ag Building, 479 proposed naturally ventilated middle school for Blacksburg, VA, 477 rate illustrative variation, 84 small middle school designed to celebrate rainwater harvesting, 480 vs mechanical ventilation, 78–9 NCM see National Calculation Method net free vent area, 464 net present value, 550 new buildings challenges facing the new build construction sector, 632–4 future trends, 645–7 legislation role, shape and trend, 634–7
725
materials for energy efficiency and thermal comfort, 631–47 new flats at risk of overheating in summer, 633 phase change materials, 640–3 thermal mass, 637–40 high-mass Queens Building in reducing peak temperatures in summer, 641 vegetation and reflective materials, 643–5 white painted houses on Mediterranean island, 646 NFVA see net free vent area night cooling, 89 with phase-change materials, 94–6 nitrogen, 258 nitrogen oxides, 508 nonenal, 156 NORDTEST Project, 347, 348, 358 normalised performance indicator, 495 normal–normal transmittance, 488, 494 notional building, 581 NPI see normalised performance indicator NPV see net present value NREL see National Renewable Energy Laboratory nucleant, 260 nucleation, 259, 260 Oak Ridge National Laboratory, 458 OECD see Organisation for Economic Co-operation and Development offgassing, xxi, 507 offices carbon dioxide emissions from ECG019’s office types Good Practice offices, 567 typical offices, 566 comparison of cumulative life cycle energy, 578 energy efficiency and thermal comfort, 563–70 air conditioning and natural ventilation, 568–70 good practice/typical practice, 566–7 journey to work, 567–8 lighting and artificial lighting, 568 main differences from dwellings, 563 range and 50th percentile for operational and embodied CO2, 564 situations, 563–6 dress code, 563 external design of office buildings, 565 internal design of office buildings, 565 office equipment, 564 productivity in office buildings, 565 sick building syndrome, 565–6 theory behind the PSALI system, 569
© Woodhead Publishing Limited, 2010
726
Index
Official Journal of the European Communities, 232 offsite construction, 428–30 future trends and materials development, 440 mechanical and electrical services, 439–40 panel systems, 434–9 concrete panel, 438–9 light steel frame, 434–5 SIPs, 437–8 timber frame, 435–7 pods and room modules, 434 pods, 434 room modules, 434 types, 431–40 volumetric buildings, 432–4 park homes and caravans, 433–4 portable and relocatable buildings, 432 volumetric (modular) building systems, 432–3 oil-filled switchgear, 609 OkSolar, 474 Ondol system, 696 opaque surface emissivity, 488 opaque wall, 700 OPEC crisis, 537 open system, 4–5 optical transparency, 335 Orange Mode Solar roof, 475 Ordinance for the Change of Chemical Ordinances, 214 Organisation for Economic Co-operation and Development, 650 oriented strandboard, 437–8, 458 oxidation reactions, 163 ozone, 159 generation, 162–3 oxidation, 369 reactions, 163 paint systems, 621–2 paints, 158, 166 palmitic acid, 386 paraffin, 384, 386, 396 effects of immersion time and PCM temperatures on PCM absorptivity, 388 Parthenocissus tricuspidata, 644 Passiv Haus Institut, 642 passive air conditioning, 354 passive cooling, 123–4 and heating strategies, 690–6 thermal energy storage materials, 123–4 passive design, 444 Passive House standard, 639 passive infrared, 618 passive nucleants, 260 passive solar systems, 699–705
PassivHaus standard, 663 refurbishment projects, 666 PCM see phase change materials PCM-gypsum wallboards, 386–9 pentachlorophenol, 158 perfluorooctane sulfonate, 166 performance assessment method, 501 performance roofs, 467–9 perlite, 223–4, 227, 378, 662 expanded, 223–4 perm, 367 Permanent Supplementary Artificial Lighting of Interiors, 568 permeability, 87 permeability/hygroscopicity, 370 perspex, 688 pesticides, 158, 512 petroleum, 512 pets, 165 phase change materials, xxii, 94, 120, 122, 123, 124, 385, 396, 445–6, 516, 584, 640–3 active, 94–5 advancements for buildings, 446–8 airtightness, 447–8 membranes, 448 moisture control, 447 application benefits of thermal energy storage, 390–4 peak-load shifting in winter season, 392–4 thermal comfort in summer season, 390–2 computer simulation, 394–6 SUNREL software, 396–7 thermal building model, 394–6 effects of immersion time and temperatures on absorptivity, 388 full-scale testing facilities, 389–90 test room schematic plan view, 389 heat energy storage and thermal comfort in buildings, 384–97 background, 385–6 hypothetical four layers of walls in the ORD case, 395 night cooling, 94–6 passive, 94 PCM selection and PCMGW fabrication, 386–9 temperature profiles in ORD and PCM cases, 397 thermo-physical properties mass types used in ORD case, 395 PCM used in PCM case, 395 use in buildings, 384–97 phenol-formaldehyde foams, 257 photocatalytic oxidation ionisation, 369 photometry, 493, 494 photovoltaic cells, 485, 489–90, 619–20
© Woodhead Publishing Limited, 2010
Index
façade-integrated PV component with local power use, 489 photovoltaic system, 658 phthalates, 160 Pilkington Suncool, 515 pine timber, 389 pipe sections, 276 pipes, xxi pipework insulation, 207 PIR see passive infra red Planck’s law, 18 Planning Policy Statement 6, 571 plaster, 164 plastics, 155, 161, 166, 688 plate replicator pods, 624 platinum-cobalt-alumina aerogel, 325 PMV see Predicted Mean Vote; predicted mean vote pods, 434 bathroom pod, 436 installation, 435 POE see post-occupancy evaluation pollen, 508 pollutants indoor-outdoor ratio, 155 WHO list, 149 polycarbonate honeycomb, 495 polyethylene, 412, 414, 688 polygonal exchanger, 402 configuration, 403 polyisocyanurate, 461 polylactide, 263 polymeric foam materials, xxi foams classification, materials and foaming mechanism, 258–62 blowing agents, 258–9 foaming mechanism, 259–62 insulation in buildings, 257–69 abbreviations, 272–3 future trends, 269 processing technologies, 262–5 batch process, 262–3 extrusion, 263–4 injection moulding, 264–5 thermoplastic and thermosetting foams, 265–9 properties, 266–9 polymers, synthetic, 372 polyolefin, 262 polyols, 264 polystyrene, 259, 413, 461, 549 expanded, 662 extruded, 662 foams, 265 polystyrenesulfonic acid sodium salt, 372 polyurethane, 155, 276, 621, 662 rigid foams, 266 polyvinyl chloride, 689 foams, 266
727
light coloured, 466 porosity, 60 porous lias clay, 225–6 porous materials, xxii, 27–9, 96–7 direct and indirect evaporative cooling in buildings, 399–423 metals, 421 potential applications in buildings, 417–22 cellulose fibre air-to-air heat and mass exchanger, 420 evaporative cooling, 417–19 façade-based evaporative cooling system, 417 heat pipe with metal wick, 421 module façades for indirect evaporative cooling, 418 module façades in building application, 419 other applications, 419–22 sharp wet front analogy applied to stage 1 and stage 2 evaporative drying, 47 three phase model, 28 Portland cement, 224 positive displacement cooling, 90 post-occupancy evaluation, 632, 668–77 Creative Energy Homes, 670 distribution panels with their individual circuits power monitoring, 674 domestic energy CO2 emissions, 671 environmental monitoring sensors, 673 E.ON UK’s 2016 Research House, 669 locations of sensors and occupants within the house, 675 thermal images of E.ON 2016 Research House, 676 potential heat, 106 potentiomers, 35 pouring method, 276 PPD see predicted percentage dissatisfied Predicted Mean Vote, 135–7, 144, 684 predicted percentage dissatisfied, 135–7 prefabricated building units and modern methods of construction, 427–40 EN 14303:2009, 281 EN 14304:2009, 281 EN 14305:2009, 281 EN 14306:2009, 281 EN 14307:2009, 281 EN 14308:2009, 281 EN 14309:2009, 281 EN 14313:2009, 281 EN 14314:2009, 281 prEN 15026, 59 EN 15715:2007, 283 prEN 15732, 226 EN 15548-1:2006, 283 EN ISO 9239-1:2008, 283 PROBE series, 632
© Woodhead Publishing Limited, 2010
728
Index
Procedures for Determining Declared and Design Thermal Values, 350 product data sheet, 293 Programme for the Endorsement of Forest Certification, 190 ProLogis, 576 PSALI see Permanent Supplementary Artificial Lighting of Interiors PSSASS see polystyrenesulfonic acid sodium salt psychrometric chart, 371 psychrometrics, xx, 26–7 public architectural space, 541 purpose-provided openings, 84 PVC see polyvinyl chloride PVL-68, 474 PVL-124, 474 PVL-136, 474 pyrogenic silicic acid, 221 pyrometry, 493 quasi-adiabatic process, 400 Quercus suber L., 242 R-values, 462 radiant barriers, 305–16 applications and assemblies, 307–9 background and definitions, 305–7 basis for thermal performance, 309–13 codes and standards, 315–16 thermal performance measurement, 313–15 radiant heaters, 576 radiation modelling, 488 radiative flux, 309 radiative heat exchange, 20 radiative heat flux, 311 rainwater harvesting system, 481, 615 Rammed Earth Design & Construction Guidelines, 354 rammed earth walls, 354 Random Mixed Cube Model, 350 Rayleigh scattering, 335 reaction heat storage, 106, 115, 118 reeds, 246, 248 reference service life, 185 reflective materials, 305–16 applications and assemblies, 307–9 background and definitions, 305–7 basis for thermal performance, 309–13 codes and standards, 315–16 standards and specifications, 317 thermal performance measurement, 313–15 reflectivity, 488 refurbishment, 654–5 approaches to low carbon retrofit systems/ technologies, 661–8 annual savings per measure for
average 3-bed semi-detached house, 664–5 PassivHaus refurbishment projects for old buildings, 667 building refurbishment energy issues, 655–6 case studies, 658–61 circa 1990 CEE high-rise comprising nine storeys, 660 five-storey residential high-rise block, 659 Riga, Latvia, 659–61 St. Petersburg, Russia, 658 change of use in buildings, 656–61 City Centre Eco-Home Conversion Project, 657 factory conversion into a city centre eco house, 657–8 materials for energy efficiency and thermal comfort of existing buildings, 649–77 POE, 668–77 Creative Energy Homes, 670 distribution panels with their individual circuits power monitoring, 674 domestic energy CO2 emissions, 671 environmental monitoring sensors, 673 E.ON UK’s 2016 Research House, 669 locations of sensors and occupants within the house, 675 thermal images of E.ON 2016 Research House, 676 stages, 655 the existing stock, 654–5 Regional Air Pollution, 508 regression analysis, 487 relative humidity, 102, 370 relative water content, 29 vs capillary potential, 36 residual moisture content, 33 resource management, 190 respiratory irritants, 153 responsible sourcing, 190 retail spaces energy efficiency and thermal comfort, 570–4 environmental design, 572 freezer cabinets in supermarkets, 573 lighting and artificial lighting, 571–2 natural ventilation and air conditioning in supermarkets, 573 shopping centres and supermarkets, 571 typical construction, 573–4 RIBA see Royal Institute of British Architects rock wool, 212, 213, 662 Roger’s model of new product diffusion, 555 roller shutters, 575
© Woodhead Publishing Limited, 2010
Index rolling insulation materials, 688 roof coatings, 466 solar reflectance and thermal performance aluminium roof coats, 469 metal roofing, 471 tinted roof coating, 469 white roof coating, 468 roof construction, 458–64 common types of roof insulation, 461 decking layers, 458–61 insulation layer, 461–4 roof decks, 459 roof gardens, 467 roof heating, 689 roof insulation, 206 roof lights, 619 roof ponds, 688 roofing system, 470 demountable precast concrete hollow core roof decking, 460 design, xxii environmentally responsive roof solutions, 457 materials, xxii materials thermal performance, 464–6 exterior weather-protection layer, 465–6 new omni-directional venturi roof vent, 471 solar impact, 464–5 solar radiation intensities, 465 membranes, 470 natural ventilation, 476–8 rainwater harvesting, 478–80 role in building rating systems, 480–1 roof construction, 458–64 decking layers, 458–61 insulation layer, 461–4 solar integrated system, 474–6 solar reflecting characteristics of roofsite tile, 470 thatched roof structures, 456 thermal performance and environmental integration of buildings, 455–81 question of design, 455–8 vegetated system, 466–74 RoofKrete, 450 rooftop air collector, 475 room modules, 434 rotatable hot box, 314 Royal Institute of British Architects, 668 RT20, 384, 387, 396 DSC graph after a number of thermal cycles, 388 RWE Ag, 478 RWE building, 478 Sainsbury Distribution Centre, 576 SAP see Standard Assessment Procedure
729
SAPO see Specified Animal Pathogens Order (2008) SBEM see Simplified Building Energy Model scatter phenomenon, 334 Scotchguard, 166 seasonal energy efficiency ratio, 383 sensible heat, 106 sensible heat storage, 107–10, 118–19 capacity, 109–10 materials, 118–19 specific heat and molecular structure, 109 specific heat and temperature, 108–9 sensors, 582–3 SERI see Solar Energy Research Institute SERIRES version 1.0, 394 SF6, 609 sharp wet front theory, 37, 44 analogy applied to stage 1 and stage 2 evaporative drying, 47 sheep’s wool, 245, 246 shopping centres, 571 short wave radiation, 20 sick building syndrome, 565–6 silica aerogel, 329 silica gel, 326, 372 silicon alkoxide, 324 silyation reaction, 329 Simplified Building Energy Model, 580–1, 612, 635 SIPs see structural insulated panels skin temperature, 135 smart materials, 358 social equity, 513 Society for the Protection of Ancient Buildings (1877), 540 Society of Environment Toxicology and Chemistry, 177 softwoods, 355 sol, 320 sol-gel process, 321–3 solar chimney, 689, 704 Solar Energy Research Institute, 394 solar gain, 96, xx absence, 700 controlled, 690 reduction, 96 solar heating, 615 solar integrated roofing system, 474–6 annual energy savings from Solar Wall enclosure system integration, 477 OMSolar thermal solar integrated roof system schematic view, 476 UniSolar Inc. PV integrated roof system, 475 solar radiation, 390, 490, 570 solariums, 688 Solarwall, 476, 576 solid masonry construction, 536, 540, 543 solid wall, 204
© Woodhead Publishing Limited, 2010
730
Index
solubility, 260 soot, 164 sorption, 105, 365 capacity, 31 curve, 380–1 filtration, 369 heat storage, 115–17 isotherms, 29–33 sorption-type storage, 115 sorptivity, 38 space heating, 153, 536, 652 spacer ring constructions, 297–8 spacing angle, 686 Spataru, 672 specific enthalpy, 103 specific heat, 107, 108 and molecular structure, 109 and temperature, 108–9 capacity, 487 Specified Animal Pathogens Order (2008), 604 spores, 164–5 spring-back effect, 330 spruce plywood, 356 stabilised earth materials, 354–5 stabilised rammed earth walls, 354 Standard Assessment Procedure, 635 Standard BS EN 15026, 15 standard environment, 132 Standard Guide for Documentation of Hygrothermal Models for Moisture Control Design in Building Envelopes, 63 standard temperature and pressure, 17 stearic acid, 386 Stefan-Boltzmann equation, 309 Stefan-Boltzmann law, 19 Stefan–Boltzmann constant, 490, 494 sticking coefficient, 156 Stirling Engine micro-combined heat and power unit, 658 stone wool, 212 STP see standard temperature and pressure straw bales, 249, 250 structural insulated panels, 434, 437–8 example, 438 suction see capillary potential sulphur dioxide, 155 sulphur oxides, 507 Sun, Wind and Light, 463 SUNREL, 384, 396–7 SUNREL version 1.04, 394 super saturation, 34 supercritical drying, 326–9 principle, 327 schematic illustrating use of carbon dioxide, 328 supermarkets, 571 energy cost breakdown, 572
freezer cabinets, 573 support constructions, 297–8 surface-fluid boundary layer, 45 surface resistance, 9, 21 surface transfer, 61 sustainability, 175 Sustainability Board, 622 sustainable thermal comfort, 144–6 sweat rate, 135 synthetic polymers, 257 Taba kana, 696 TARBASE research group, 538, 541, 554 Target Emission Rate, 581 Technical Committee TC350, 187 Teflon, 162, 166 TER see Target Emission Rate TermoDeck panels, 639 terpenes, 157 terpentine oils, 162 tetraethoxysilane, 324 tetramethylthiuram monosulphide, 155 The Lighthouse, 498 theory of equipartition energy, 109 thermal battery, 445 thermal buffer value, 349 thermal buffering, 359 thermal building model, 394–6 thermal capacity, 487 thermal comfort, xix, xx, xxii, xxiii, 506–7 applications of design and passive technologies in modern buildings, 696–8 Baer residence, 698 Centre for Energy Studies, 697 Jeddah International Airport, 697 Patoka Interpretative Nature Centre, 698 University guest house, 698 approaches and lessons learned from traditional hot-climate architecture, 689–96 behavioural thermoregulation, thermal comfort and the adaptive model, 141–2 buildings, 127–46 climate impact on building fabric, 688–9 glazing, 688 thermal insulation, 688 thermal storage, 688–9 climate impact on urban pattern and building form and fabric, 685–7 building form, 686–7 roof form, 687 street planning, 686 definition, 127–9 design and passive technologies in buildings in hot and tropical climates, 681–705
© Woodhead Publishing Limited, 2010
Index different climates, 681–5 global criteria, 683–5 influencing parameters, 682 domestic buildings materials, 533–59 equivalent clothing index, 142–4 the comfort temperature range and temperature limits in offices, 144 high performance buildings materials, 589–625 indices, 132–7 clothing insulation values estimates, 138 comfort equation, 133 equations for components of heat balance equation, 134 Fanger, 133 heat balance, 134–5 metabolic rates estimates, 138 PMV values from Fanger, 139 predicted mean vote and predicted percentage dissatisfied, 135–7 relationship between PMV and PPD, 137 six basic parameters, 132–3 sweat rate and skin temperature for comfort, 135 terms used in predicted mean vote, 134 International Standards, 137–41 ISO 7726: thermal environment, 141 ISO 7730: moderate thermal environments, 138–41 ISO 10551: assessing the influence of thermal environment, 141 subjective scales considered in ISO 10551, 141 materials for the refurbishment of existing buildings, 649–77 measurement, 129–32 ASHRAE and Bedford scales of warmth sensation, 130 behavioural and observational measures, 131–2 subjective measures, 129–31 new buildings materials, 631–47 passive solar systems thermal performance, 699–704 mass wall, 699 trombe wall with vents, 701 wall solar chimney, 703 PCM use in buildings, 384–97 quantification, xxi sustainable thermal comfort, 144–6 thermal index: an assessment technique, 132 traditional passive cooling and heating strategies, 690–6 city of Ghadames, Libya, 693–4 city of Marrakech, Morocco, 690 mountain dwellings of Morocco, 691
731
Mzab valley, Algeria, 691–2 Ondol system, 696 town of El-Oued, Algeria, 692 traditional architecture in Egypt, 694–5 traditional floor heating in Korea, China and Afghanistan, 696 underground dwellings in Libya, 692–3 values for range of adaptive opportunities, 143 Thermal Comfort, 133 thermal conduction, 8, 119 moisture-dependent, 10–11 transient, 11–14 thermal conductivity, 10, 235, 266–7, 274, 280, 333, 406 boards and mats, 290 declared values, 287–8 compression, 287 convection, 287 for joints, 287 gas exchange, 288 IR permeability, 288 temperature difference, 287 effective, 493 insulation materials depending on apparent density and temperature, 281 depending on apparent density and thickness, 282 linear equation, 290 preformed pipe insulation material, 290 test standards boards and mats, 282 pipe sections and tubes, 283 thermal convection, 14–18 thermal decrement factor, 23 thermal diffusivity, 11–12 thermal effusivity, 12, 347 thermal energy, 347 thermal energy storage, 101, 385, 396 application benefits, 390–4 peak-load shifting in winter season, 392–4 thermal comfort in summer season, 390–2 comparison of weekly-averaged indoor air temperatures, 392 incorporated with active cooling/heating, 124 materials, 118–22 chemical heat storage, 120–1 heat transfer in heat storage materials, 121–2 latent heat storage, 119–20 sensible heat storage, 118–19 materials for passive cooling, 123–4 operating strategies, 386
© Woodhead Publishing Limited, 2010
732
Index
PCM use in buildings, 384–97 solar radiation and wind speed summer readings, 390 winter readings, 393 summer ambient and indoor temperatures in two rooms, 391 winter ambient and indoor temperatures in two rooms, 393 thermal index, 132 thermal inertia, 385 thermal insulation, xx, xxi, 193, 688 Thermal Insulation – Determination of Steady State Thermal Resistance and Related Properties, 350 thermal insulation material claddings, 298 for building equipment, 274– 303 form pieces and form parts, 296–7 form piece made of polyurethane, 297 pre-manufactured form piece, 297 insulation materials, 275–96 declaration of conformity and designation, 293–5 declared value, 287–93 employability as insulant, 279 fundamentals, 275–87 influential factors when determining thermal conductivity, 289 label for designation, 296 mineral wool insulant composition of designation code, 295 minimum and maximum service temperatures, 292 possible fire behaviour classes, 292 product data sheet, 293 quality assurance/third party control, 295–6 readily available insulation products, 277–9 symbols for properties, levels and classes for designation code, 294 temperature application ranges, 280 thermal conductivity depending on apparent density and temperature, 281 thermal conductivity of insulants depending on apparent density and thickness, 282 values for industrial installations, 291 water vapour diffusion resistance factor, 293 insulation system, 298–301 general, 298–9 properties, 299–301 operational installation heat loss, 301–3 heat transfer coefficient values of claddings, 302 national regulations, 303
required insulation layer thickness, 302–3 support and spacer ring constructions, 297–8 vapour retarder materials, 298 various surfaces emissivity, 298 thermal insulation product life cycle key phases end-of-life, 208 installation, 208 insulation manufacture, 207–8 packaging, 208 raw materials extraction and processing, 207 transport to retail unit, 208 use and maintenance, 208 thermal load, 135 thermal mass, 23, 347, 371, 516, 579–80, 637–40, 662 conventional, 643 high-mass Queens Building in reducing peak temperatures in summer, 641 in offsite potential, 445 principal applications, 637–8 thermal modelling software, 612 thermal performance, xxii measurement, 313–15 thermal radiation, 18–20 thermal resistance, 9, 195, 196, 306, 308, 463, 700 calculated values for reflective air spaces, 308 dependence on distance across air space, 308 values, 458–9 thermal resistivity, 487 thermal storage, xx, 89, 516, 579, 688–9 thermal storage density, 110 thermal transmission coefficient, 194 thermal transmittance, 9 thermal zone, 394 thermodec sell, 516 thermodynamics, 106 thermoplastic foams, 265–9 properties, 266–9 density, 266 flammability, 268–9 mechanical properties, 267–8 thermal conductivity, 266–7 thermosetting foams properties, 266–9 density, 266 flammability, 268–9 mechanical properties, 267–8 thin solutions, 444–5 timber, 355–6 timber frame, 434, 435–7, 540 closed cell panel system, 437
© Woodhead Publishing Limited, 2010
Index construction example Innovare Systems Limited, 437 Prestoplan Limited, 437 fleet cell panel system, 436 open cell panel system, 435–6 tip speed ratio, 491 tortuosity, 41 torus, 355 total heat loss, 302 total heat transfer coefficient, 700 TOXFIRE, 155 Toyota Prius, 511 traditional architecture application in buildings in hot and tropical climates, 681–705 approaches and lessons learned, 689–96 climate impact on building fabric, 688–9 climate impact on urban pattern and building form and fabric, 685–7 thermal comfort in different climates, 681–5 thermal performance in passive solar systems, 699–705 application in modern buildings, 696–8 transmissivity, 488 transparent insulation, 488 impact of staining on transmissivity, 489 Transport Phenomena, 6 Trespa, 603 tris(2-chloroisopropyl)phosphate, 160 Trombe-like system, 689 Trombe wall, 688, 701, 703 with vents, 701 tropical summer index, 685 TSI see tropical summer index U-value, 26, 195, 537, 549, 639 UBISENSE, 672 UFF see urea-formaldehyde foam UHTS see ultra-high throughput screening UK Building Regulations, 149, 165, 580, 606, 612, 623, 671 UK Department for Environment, Food and Rural Affairs, 161 UKCIP02, 544 ULPA filtration see ultra low particulate air filtration ultra-high throughput screening, 591, 625 robotic compound store by REMP, 625 ultra low particulate air filtration, 605 ultralow density aerogels, 336 UNESCO, 693 UniSolar Inc, 474 uptake coefficient, 156 urban heat island, 512 intensity, 634 urea-formaldehyde foam, 161, 165, 257
733
US Department of Energy, 385, 466 US Environmental Protection Agency, 150 US Green Building Council, 478, 480 US National Renewable Energy Labs website, 474 US STD 209E, 599, 605 Usable Buildings Trust, 632 vacuum-based switchgear, 609 vacuum insulation panels, 221, 222 vacuum saturation, 28 Vales Rooms, 638 valuation see weighting van der Waals, 29, 381 vaporised hydrogen peroxide, 603 vapour barrier, 286 vapour diffusion, 40–3 vapour permeability, 60 vapour pressure, 58 vapour retarder materials, 298 varnishes, 158 VDI 2055, 298, 300 VDI/Keymark, 295–6 vegetated roofing system, 466–74 Green Tech Inc. polyethylene modular green roof trays, 473 horizontal surface temperatures for various sunlit materials, 472 ventilation, xx, 476–8, 517–18, 704 see also mechanical ventilation; natural ventilation air quality and airtightness in buildings, 77–99 future trends, 97–8 feasibility of natural ventilation, 86–90 airtightness, 87–8 building envelope, 87 climate, 86–7 control, 90 cooling, 88–9 evaporative cooling, 89–90 internal heat gains, 90 occupants, 88 thermal storage, 89 Ionica Building and RWE Ag Building, 479 issues concerning materials, 92–7 adventitious leakage on balanced mechanical system, 93 adventitious leakage on natural ventilation system, 93 air quality, 97 airtightness, 92–4 night cooling with phase-change materials, 94–6 porous materials and dynamic insulation, 96–7 reducing solar gains, 96 room air temperature variations, 95
© Woodhead Publishing Limited, 2010
734
Index
mixing ventilation, 81 natural ventilation design, 90–2 basic procedures, 90–2 design criteria, 92 ventilation strategy, 91 physical mechanisms, 81–6 air quality, 85–6 envelope flows, 81–2 flow through envelope openings, 83 internal air motion, 85 natural ventilation characteristics, 83–4 natural ventilation rate illustrative variation, 84 types of envelope openings, 84 proposed naturally ventilated middle school for Blacksburg, VA, 477 small middle school designed to celebrate rainwater harvesting, 480 system, 77–81 differences, 78–9 internal air motion, 81 low-energy ventilation systems, 79–81 types, 77–8 ventilation rate, 83 Venturi effect, 466, 478 vermiculite, 224–5, 412, 662 exfoliated, 224–5 typical composition, 225 Veterinary Medicines Directorate, 599 VHP see vaporised hydrogen peroxide vinyl, 621 virtual thermal mass, 446 VMD see Veterinary Medicines Directorate volatile organic compounds, 369, 372 microbial, 164 Volatile Organic Compounds in Indoor Air: A Review of Concentrations Measured in North America Since 1990, 150 volumetric buildings, 432–4 modular building, 433 park homes and caravans, 433–4 photo of portable/re-locatable building, 432 portable and relocatable buildings, 432 volumetric (modular) building systems, 432–3 voluntary product certification, 198
heating requirement and systems, 576 lighting and daylight control, 575–6 typical construction, 576–7 vernacular construction, 577 warm frame principle, 435 waste minimisation, 513 water absorption coefficient, 39 water capacity, 380–1 water course, 616 water heating, 652 water ponds, 689 water retaining capability, 406, 412 water retaining potential, 414 water vapour diffusion, 286–7 equivalent air layer thickness, 286–7 resistance factor, 41, 286, 293 water vapour flow rate, 43 water vapour permeability, 381 water vapour permeance, 43 water walls, 688 waterglass, 335 wax, 414 weather bin values, 383 weighting, 181 wet-bulb temperature, 103 wet cup/dry cup method, 42 wet cup test, 42 WHO see World Health Organisation wind, 704 wind power turbines, 608, 616–17 wind speed, 390 wind tunnel tests, 492 wood, 157, 381–2, 696 wood chippings, 249 wood fibre, 242, 243 wooden fibres, 412 woodwool, 242 composite boards, 240 work, 4 World Heritage List of Historical Monuments, 693 WTA Guideline 6-2, 58, 61 WUFI model, 58 WUFI software, 357
wall solar chimney, 703 wall thickness, 406 warehouses, 575 energy efficiency and thermal comfort, 574–7 environmental design, 575–6 collection of heat for warm-air system and radiant heating system, 576
zeolites, 372, 413–14, 422 crystalline, 413–14 natural, 413 synthetic, 372, 413 zero-carbon, 631, 636, 645 dwelling definition structure, 636 home, 671 zirconia, 325
xerogel, 320 Young’s modulus, 408, 411, 412, 413, 414, 415
© Woodhead Publishing Limited, 2010