Innovative Food Processing Technologies: Advances in Multiphysics Simulation Kai Knoerzer, Pablo Juliano, Peter Roupas, ...
142 downloads
819 Views
81MB Size
Report
This content was uploaded by our users and we assume good faith they have the permission to share this book. If you own the copyright to this book and it is wrongfully on our website, we offer a simple DMCA procedure to remove your content from our site. Start by pressing the button below!
Report copyright / DMCA form
Innovative Food Processing Technologies: Advances in Multiphysics Simulation Kai Knoerzer, Pablo Juliano, Peter Roupas, and Cornelis Versteeg EDITORS
A John Wiley & Sons, Inc., Publication
The IFT Press series reflects the mission of the Institute of Food Technologists—to advance the science of food contributing to healthier people everywhere. Developed in partnership with Wiley-Blackwell, IFT Press books serve as leading-edge handbooks for industrial application and reference and as essential texts for academic programs. Crafted through rigorous peer review and meticulous research, IFT Press publications represent the latest, most significant resources available to food scientists and related agriculture professionals worldwide. Founded in 1939, the Institute of Food Technologists is a nonprofit scientific society with 22,000 individual members working in food science, food technology, and related professions in industry, academia, and government. IFT serves as a conduit for multidisciplinary science thought leadership, championing the use of sound science across the food value chain through knowledge sharing, education, and advocacy. IFT Press Advisory Group Casimir C. Akoh Christopher J. Doona Jung Hoon Han David B. Min Ruth M. Patrick Syed S.H. Rizvi Fereidoon Shahidi Christopher H. Sommers Yael Vodovotz Mark Barrett Karen Nachay Margaret Kolodziej IFT Press Editorial Board Malcolm C. Bourne Dietrich Knorr Theodore P. Labuza Thomas J. Montville S. Suzanne Nielsen Martin R. Okos Michael W. Pariza Barbara J. Petersen David S. Reid Sam Saguy Herbert Stone Kenneth R. Swartzel
A John Wiley & Sons, Inc., Publication
This edition first published 2011 © 2011 by John Wiley & Sons, Ltd. and Institute of Food Technologists Wiley-Blackwell is an imprint of John Wiley & Sons, formed by the merger of Wiley’s global Scientific, Technical and Medical business with Blackwell Publishing. Registered office:
John Wiley & Sons, Ltd, The Atrium, Southern Gate, Chichester, West Sussex, PO19 8SQ, UK
Editorial offices: 2121 State Avenue, Ames, Iowa 50014-8300, USA The Atrium, Southern Gate, Chichester, West Sussex, PO19 8SQ, UK 9600 Garsington Road, Oxford, OX4 2DQ, UK For details of our global editorial offices, for customer services and for information about how to apply for permission to reuse the copyright material in this book please see our website at www.wiley.com/wiley-blackwell. Authorization to photocopy items for internal or personal use, or the internal or personal use of specific clients, is granted by Blackwell Publishing, provided that the base fee is paid directly to the Copyright Clearance Center, 222 Rosewood Drive, Danvers, MA 01923. For those organizations that have been granted a photocopy license by CCC, a separate system of payments has been arranged. The fee codes for users of the Transactional Reporting Service are ISBN-13: 978-0-8138-1754-5/2011. Designations used by companies to distinguish their products are often claimed as trademarks. All brand names and product names used in this book are trade names, service marks, trademarks or registered trademarks of their respective owners. The publisher is not associated with any product or vendor mentioned in this book. This publication is designed to provide accurate and authoritative information in regard to the subject matter covered. It is sold on the understanding that the publisher is not engaged in rendering professional services. If professional advice or other expert assistance is required, the services of a competent professional should be sought. Library of Congress Cataloging-in-Publication Data Innovative food processing technologies: advances in multiphysics simulation / [edited by] Kai Knoerzer ... [et al.]. p. cm.—(IFT Press series) Includes bibliographical references and index. ISBN 978-0-8138-1754-5 (hardback) 1. Food industry and trade–Mathematical methods. 2. Food industry and trade–Simulation methods. I. Knoerzer, Kai. TP370.9.M38M85 2011 664'.020113–dc22 2010044300 A catalogue record for this book is available from the British Library. This book is published in the following electronic formats: ePDF 9780470959411; Wiley Online Library 9780470959435; ePub 9780470959428 Set in 10/12 Times by Toppan Best-set Premedia Limited, Hong Kong Disclaimer The publisher and the author make no representations or warranties with respect to the accuracy or completeness of the contents of this work and specifically disclaim all warranties, including without limitation warranties of fitness for a particular purpose. No warranty may be created or extended by sales or promotional materials. The advice and strategies contained herein may not be suitable for every situation. This work is sold with the understanding that the publisher is not engaged in rendering legal, accounting, or other professional services. If professional assistance is required, the services of a competent professional person should be sought. Neither the publisher nor the author shall be liable for damages arising herefrom. The fact that an organization or Website is referred to in this work as a citation and/or a potential source of further information does not mean that the author or the publisher endorses the information the organization or Website may provide or recommendations it may make. Further, readers should be aware that Internet Websites listed in this work may have changed or disappeared between when this work was written and when it is read. 1
2011
Titles in the IFT Press series • Accelerating New Food Product Design and Development (Jacqueline H. Beckley, Elizabeth J. Topp, M. Michele Foley, J.C. Huang, and Witoon Prinyawiwatkul) • Advances in Dairy Ingredients (Geoffrey W. Smithers and Mary Ann Augustin) • Bioactive Proteins and Peptides as Functional Foods and Nutraceuticals (Yoshinori Mine, Eunice Li-Chan, and Bo Jiang) • Biofilms in the Food Environment (Hans P. Blaschek, Hua H. Wang, and Meredith E. Agle) • Calorimetry in Food Processing: Analysis and Design of Food Systems (Gönül Kaletunç) • Coffee: Emerging Health Effects and Disease Prevention (YiFang Chu) • Food Carbohydrate Chemistry (Ronald E. Wrolstad) • Food Ingredients for the Global Market (Yao-Wen Huang and Claire L. Kruger) • Food Irradiation Research and Technology (Christopher H. Sommers and Xuetong Fan) • Foodborne Pathogens in the Food Processing Environment: Sources, Detection and Control (Sadhana Ravishankar, Vijay K. Juneja, and Divya Jaroni) • High Pressure Processing of Foods (Christopher J. Doona and Florence E. Feeherry) • Hydrocolloids in Food Processing (Thomas R. Laaman) • Improving Import Food Safety (Wayne C. Ellefson, Lorna Zach, and Darryl Sullivan) • Innovative Food Processing Technologies: Advances in Multiphysics Simulation (Kai Knoerzer, Pablo Juliano, Peter Roupas, and Cornelis Versteeg) • Microbial Safety of Fresh Produce (Xuetong Fan, Brendan A. Niemira, Christopher J. Doona, Florence E. Feeherry, and Robert B. Gravani) • Microbiology and Technology of Fermented Foods (Robert W. Hutkins) • Multivariate and Probabilistic Analyses of Sensory Science Problems (Jean-François Meullenet, Rui Xiong, and Christopher J. Findlay • Nanoscience and Nanotechnology in Food Systems (Hongda Chen) • Natural Food Flavors and Colorants (Mathew Attokaran) • Nondestructive Testing of Food Quality (Joseph Irudayaraj and Christoph Reh) • Nondigestible Carbohydrates and Digestive Health (Teresa M. Paeschke and William R. Aimutis) • Nonthermal Processing Technologies for Food (Howard Q. Zhang, Gustavo V. Barbosa-Cánovas, V.M. Balasubramaniam, C. Patrick Dunne, Daniel F. Farkas, and James T.C. Yuan) • Nutraceuticals, Glycemic Health and Type 2 Diabetes (Vijai K. Pasupuleti and James W. Anderson) • Organic Meat Production and Processing (Steven C. Ricke, Michael G. Johnson, and Corliss A. O’Bryan) • Packaging for Nonthermal Processing of Food (Jung H. Han) • Preharvest and Postharvest Food Safety: Contemporary Issues and Future Directions (Ross C. Beier, Suresh D. Pillai, and Timothy D. Phillips, Editors; Richard L. Ziprin, Associate Editor) • Processing and Nutrition of Fats and Oils (Ernesto M. Hernandez and Afaf Kamal-Eldin) • Processing Organic Foods for the Global Market (Gwendolyn V. Wyard, Anne Plotto, Jessica Walden, and Kathryn Schuett) • Regulation of Functional Foods and Nutraceuticals: A Global Perspective (Clare M. Hasler) • Resistant Starch: Sources, Applications and Health Benefits (Yong-Cheng Shi and Clodualdo Maningat) • Sensory and Consumer Research in Food Product Design and Development (Howard R. Moskowitz, Jacqueline H. Beckley, and Anna V.A. Resurreccion) • Sustainability in the Food Industry (Cheryl J. Baldwin) • Thermal Processing of Foods: Control and Automation (K.P. Sandeep) • Trait-Modified Oils in Foods (Frank T. Orthoefer and Gary R. List) • Water Activity in Foods: Fundamentals and Applications (Gustavo V. Barbosa-Cánovas, Anthony J. Fontana Jr., Shelly J. Schmidt, and Theodore P. Labuza) • Whey Processing, Functionality and Health Benefits (Charles I. Onwulata and Peter J. Huth)
Contents
Preface, ix Contributors, xiii 1.
Introduction to Innovative Food Processing Technologies: Background, Advantages, Issues, and Need for Multiphysics Modeling, 3 Gustavo V. Barbosa-Cánovas, Abdul Ghani Albaali, Pablo Juliano, and Kai Knoerzer
2.
The Need for Thermophysical Properties in Simulating Emerging Food Processing Technologies, 23 Pablo Juliano, Francisco Javier Trujillo, Gustavo V. Barbosa-Cánovas, and Kai Knoerzer
3.
Neural Networks: Their Role in High-Pressure Processing, 39 José S. Torrecilla and Pedro D. Sanz
4.
Computational Fluid Dynamics Applied in High-Pressure Processing Scale-Up, 57 Cornelia Rauh and Antonio Delgado
5.
Computational Fluid Dynamics Applied in High-Pressure High-Temperature Processes: Spore Inactivation Distribution and Process Optimization, 75 Pablo Juliano, Kai Knoerzer, and Cornelis Versteeg
6.
Computer Simulation for Microwave Heating, 101 Hao Chen and Juming Tang
7.
Simulating and Measuring Transient Three-Dimensional Temperature Distributions in Microwave Processing, 131 Kai Knoerzer, Marc Regier, and Helmar Schubert
8.
Multiphysics Modeling of Ohmic Heating, 155 Peter J. Fryer, Georgina Porras-Parral, and Serafim Bakalis
9.
Basics for Modeling of Pulsed Electric Field Processing of Foods, 171 Nicolás Meneses, Henry Jaeger, and Dietrich Knorr
10.
Computational Fluid Dynamics Applied in Pulsed Electric Field Preservation of Liquid Foods, 193 Nicolás Meneses, Henry Jaeger, and Dietrich Knorr vii
viii
Contents
11.
Novel, Multi-Objective Optimization of Pulsed Electric Field Processing for Liquid Food Treatment, 209 Jens Krauss, Özgür Ertunç, Cornelia Rauh, and Antonio Delgado
12.
Modeling the Acoustic Field and Streaming Induced by an Ultrasonic Horn Reactor, 233 Francisco Javier Trujillo and Kai Knoerzer
13.
Computational Study of Ultrasound-Assisted Drying of Food Materials, 265 Enrique Riera, José Vicente García-Pérez, Juan Andrés Cárcel, Victor M. Acosta, and Juan A. Gallego-Juárez
14.
Characterization and Simulation of Ultraviolet Processing of Liquid Foods Using Computational Fluid Dynamics, 303 Larry Forney, Tatiana Koutchma, and Zhengcai Ye
15.
Multiphysics Modeling of Ultraviolet Disinfection of Liquid Food—Performance Evaluation Using a Concept of Disinfection Efficiency, 325 Huachen Pan
16.
Continuous Chromatographic Separation Technology—Modeling and Simulation, 335 Filip Janakievski
17.
The Future of Multiphysics Modeling of Innovative Food Processing Technologies, 353 Peter J. Fryer, Kai Knoerzer, and Pablo Juliano
Index, 365 Color plate section appears between pages 208 and 209.
Preface
The food industry is an increasingly competitive and dynamic arena, with consumers now more aware of what they eat and, more importantly, what they want to eat. Important food quality attributes such as taste, texture, appearance, and nutritional content are strongly dependent on the way the foods are processed. In recent years, with the aim to improve, or replace, conventional processing technologies in order to deliver higher-quality and better consumertargeted food products, a number of innovative technologies, also referred to as “emerging” or “novel” technologies have been proposed, investigated, developed, and in some cases, implemented. These technologies take advantage of other physics phenomena such as high hydrostatic pressure, electric and electromagnetic fields, and pressure waves. Some of the most promising innovative technologies, in various stages of development and adoption, are discussed in this book, namely high-pressure processing (also in combination with heat), microwave processing, ohmic heating, pulsed electric field processing, ultrasound processing (liquid- and airborne), ultraviolet light (UV) processing, and enhanced continuous separation. These innovative technologies provide the opportunity not only for the development of new foods but also for improving the safety and quality of conventional foods through milder processing. Different physical phenomena, utilized by these technologies, can potentially reduce energy and water consumption and therefore assist in reducing the
carbon and water footprint of food processing, thus playing an important role toward environmental sustainability and global food security. Apart from the underlying thermo- and fluiddynamic principles of conventional processing, these innovative technologies incorporate additional Multiphysics dimensions, for example, pressure waves, electric and electromagnetic fields, among others. To date, some of them still lack an adequate, complete understanding of the basic principles of intervening in temperature and flow evolution in product and equipment during processing. Their proper application, development and optimization of suitable equipment and process conditions still require a significant amount of further knowledge. Computational Fluid Dynamics (CFD) is already established as a tool for characterizing, improving, and optimizing traditional food processing technologies. Innovative technologies, however, provide additional complexity and challenges for modelers because of the concurrent interacting Multiphysics phenomena. In order to differentiate Multiphysics modeling from CFD modeling, the word “Multiphysics” will be capitalized throughout the book. Four symposia were organized at two consecutive Annual Meetings of the Institute of Food Technologists (IFT) in 2008 and 2009 (New Orleans and Anaheim, respectively) to gather Multiphysics modeling experts in innovative technologies to present and discuss the latest advances in their respective fields. These symposia highlighted the ix
x
Preface
importance and key role of Multiphysics modeling to further advance the development of each innovative technology and facilitate their introduction into the food industry. Written by international experts from world-class research centers, academia, and industry, this book explains and discusses how Multiphysics modeling—that is, the simulation of the entire process comprising the actual equipment, varying process conditions, and the thermophysical properties of the food to be treated—can be applied in the development, optimization, and scale-up of innovative food processing technologies. The most recent research outcomes are shown to demonstrate benefits to process efficiency and the impact on scalability, safety, and quality. The first part of this book includes two chapters introducing the rationale of the book and some common themes to all chapters. Chapter 1 is the introductory chapter outlining the range of innovative processing technologies covered, briefly describing the technologies and making the case for the necessity of Multiphysics modeling for their design, development, and application. Chapter 2 discusses the importance of determining the relevant (common and technology-specific) thermophysical properties and their essential role for accurate model prediction. The second part of the book is an extensive collection of chapters devoted to the various case studies on the modeling of innovative food processing technologies. For clarity and convenience, they are divided into subsections focusing on high-pressure processing (Chapters 3–5), technologies utilizing electric and/or electromagnetic effects (microwave, ohmic heating, and pulsed electric field processing; Chapters 6–11), processes using ultrasound waves (in liquids or air) (Chapters 12 and 13), ultraviolet light (UV) processing (Chapters 14 and 15), and finally, one chapter on innovative chromatographic separation technologies (Chapter 16). Chapter 3 discusses two fundamentally different modeling approaches to characterize high-pressure (low-temperature) systems. It introduces the reader to the very promising modeling technique known as artificial neural networks (ANN), as well as the more
generalized visual programming approach referred to as macroscopic modeling. In Chapters 4 and 5, “conventional” CFD modeling approaches for highpressure processes at both low and high temperatures are discussed and their application for equipment design, scale-up, and optimization are highlighted. Also described is their application to present the process outcomes in terms of safety and quality of the processed foods. Chapter 6 and 7 covers the extension of classical CFD with a further Multiphysics dimension, electromagnetic radiation, and the implementation for designing and characterizing microwave heating processes. Chapter 7 also discusses various temperature mapping techniques and introduces the use of magnetic resonance imaging (MRI) for the determination of microwaveinduced three-dimensional heating patterns. In Chapter 8, historical and new developments of Multiphysics modeling applied to ohmic heating are presented. Chapters 9, 10, and 11 are devoted to modeling of pulsed electric fields processing, covering the basics of the technology, its application for predicting liquid food pasteurization, and the “multiobjective” optimization of the technology for liquid food processing. Chapters 12 and 13 present two distinctly different ultrasound applications. Chapter 12 covers liquid-borne ultrasound, including a review on its use in food processing, followed by an extensive review of the mathematics and physics involved in this technology, and this is concluded with a novel approach of modeling ultrasound-induced streaming. Chapter 13 details the use of airborne ultrasound for the improvement of drying processes at low temperatures. The complex mathematics is described and the chapter is concluded by experimental studies, highlighting the advantages and commercial potential of this innovative drying technology. Chapters 14 and 15 both describe UV processing for liquid food disinfection/pasteurization as an effective alternative to thermal treatments. Chapter 14 focuses on the characterization of several alternative reactor designs by Multiphysics modeling, whereas Chapter 15 compares the performance of different commercially available reactors using Multiphysics modeling and the introduction of the concept of “disinfection efficiency.” The final technology chapter (Chapter
Preface
16) introduces an innovative continuous separation process based on the chromatographic simulated moving bed principle. It outlines the procedure of modeling these types of technologies and highlights the advantages over conventional column or bedbased separation processes. Chapter 17 is the take-home message of this book, which concludes with a summary on what was presented in the chapters before and provides an outlook on future trends in Multiphysics simulation of innovative food processing technologies. Three questions are posed: (1) What can be usefully modeled today?; (2) What extra data is needed?; and (3) How much detail is needed, or Where shall we stop? This chapter is not intended to provide definitive answers to these questions, but it suggests some future research directions and places where research ought to or is expected to arrive.
xi
The editors wish to thank all collaborators in this book for their excellent contributions, and the time and effort they have devoted to making this book a comprehensive interdisciplinary reference source for engineers, technologists and scientists, and researchers from academia and industry alike. We believe that the value of this book is not limited to food engineering; it is also useful for other branches of process and chemical engineering. We would also like to thank the Institute of Food Technologist’s Nonthermal Processing Division, the International Division, and the Food Engineering Division for sponsoring the session symposia that led to the development of this book. Kai Knoerzer Pablo Juliano Peter Roupas Cornelis Versteeg
Contributors
Víctor M. Acosta Grupo de Ultrasonidos de Potencia Consejo Superior de Investigaciones Científicas (CSIC) Serrano, 144, E28006 Madrid, Spain
Hao Chen Department of Biological Systems Engineering Washington State University Pullman, WA 99164-6120 (Currently with Microsoft, Redmond, WA)
Abdul Ghani Albaali Princess Sumaya University for Technology P.O. Box 1438 Al-Jubaiha 11941 Jordan
Antonio Delgado Institute of Fluid Mechanics Friedrich-Alexander University Erlangen-Nuremberg Cauerstrasse 4, D-91058 Erlangen Germany
Serafim Bakalis Centre for Formulation Engineering School of Chemical Engineering University of Birmingham Birmingham B15 2TT United Kingdom
Özgür Ertunç Institute of Fluid Mechanics Friedrich-Alexander University Erlangen-Nuremberg Cauerstrasse 4, D-91058 Erlangen Germany
Gustavo V. Barbosa-Cánovas Department of Biological Systems Engineering Washington State University Pullman, WA 99164-6120
Larry Forney School of Chemical and Biomolecular Engineering Georgia Institute of Technology 311 Ferst Drive, N.W. Atlanta, GA 30332
Juan Andrés Cárcel Grupo de Análisis y Simulación de Procesos Agroalimentarios (ASPA) Departamento de Tecnología de Alimentos Universidad Politécnica de Valencia Camí de Vera s/n, E46022, Valencia Spain
Peter J. Fryer Centre for Formulation Engineering School of Chemical Engineering University of Birmingham Birmingham B15 2TT United Kingdom xiii
xiv
Contributors
Juan A. Gallego-Juárez Grupo de Ultrasonidos de Potencia Consejo Superior de Investigaciones Científicas (CSIC) Serrano, 144, E28006, Madrid Spain José Vicente García-Pérez Grupo de Análisis y Simulación de Procesos Agroalimentarios (ASPA) Departamento de Tecnología de Alimentos Universidad Politécnica de Valencia Camí de Vera s/n, E46022, Valencia Spain Henry Jaeger Department of Food Biotechnology and Food Process Engineering Technische Universität Berlin Koenigin-Luise-Str. 22 D-14195 Berlin Germany Filip Janakievski CSIRO Food and Nutritional Sciences 671 Sneydes Road Werribee, VIC 3030 Australia Pablo Juliano CSIRO Food and Nutritional Sciences 671 Sneydes Road Werribee, VIC 3030 Australia Dietrich Knorr Department of Food Biotechnology and Food Process Engineering Technische Universität Berlin Koenigin-Luise-Str. 22 D-14195 Berlin Germany Tatiana Koutchma Guelph Food Research Centre, Agriculture and Agri-Food Canada 93 Stone Road West Guelph, ON, N1G 5C9 Canada
Jens Krauss Institute of Fluid Mechanics Friedrich-Alexander University Erlangen-Nuremberg Cauerstrasse 4, D-91058 Erlangen Germany Kai Knoerzer CSIRO Food and Nutritional Sciences 671 Sneydes Road Werribee, VIC 3030 Australia Nicolás Meneses Department of Food Biotechnology and Food Process Engineering Technische Universität Berlin Koenigin-Luise-Str. 22 D-14195 Berlin Germany Huachen Pan Institute of Mechatronic Engineering Hangzhou Dianzi University 310018 Hangzhou China Georgina Porras-Parral Centre for Formulation Engineering School of Chemical Engineering University of Birmingham Birmingham B15 2TT United Kingdom Cornelia Rauh Institute of Fluid Mechanics Friedrich-Alexander University Erlangen-Nuremberg Cauerstrasse 4, D-91058 Erlangen Germany Marc Regier Fachhochschule Trier University for Applied Sciences Schneidershof, 54293 Trier Germany
Contributors
Enrique Fernando Riera Franco de Sarabia Grupo de Ultrasonidos de Potencia Consejo Superior de Investigaciones Científicas (CSIC) Serrano, 144, E28006, Madrid Spain
José S. Torrecilla Department of Chemical Engineering Universidad Complutense de Madrid Avenida Complutense s/n 28040 Madrid Spain
Pedro D. Sanz Malta Consolider Team Department of Processes ICTAN, CSIC c/ José Antonio Novais, 10 28040 Madrid Spain
Francisco Javier Trujillo CSIRO Food and Nutritional Sciences 11 Julius Avenue North Ryde, NSW 2113 Australia
Helmar Schubert Universitaet Karlsruhe (TH)/Karlsruhe Institute of Technology (KIT) Institute of Engineering in Life Sciences Dept. I: Food Process Engineering Karlsruhe, Germany Juming Tang Department of Biological Systems Engineering Washington State University Pullman, WA 99164-6120
Cornelis Versteeg CSIRO Food and Nutritional Sciences 671 Sneydes Road Werribee, VIC 3030 Australia Zhengcai Ye Bechtel Oil, Gas and Chemicals, Inc. 3000 Post Oak Blvd Houston, TX 77056
xv
Chapter 1 Introduction to Innovative Food Processing Technologies: Background, Advantages, Issues, and Need for Multiphysics Modeling Gustavo V. Barbosa-Cánovas, Abdul Ghani Albaali, Pablo Juliano, and Kai Knoerzer
1.1. Introduction In a world that is demanding environmental sustainability and food security, innovation is a key requirement for the sustained growth of the food industry. Furthermore, product innovation is the response to the growing demand for value addition along with more sophisticated and diverse food products. Modern food technology provides a handful of novel processing options to explore, which could provide more diverse food industry products and more competitive and efficient processes. Many of these innovative technologies can provide new opportunities for the development of new foods and for the improvement of safety and quality of more conventionally manufactured foods through milder processing. This book discusses innovative technologies that take advantage of physical forces and phenomena such as high hydrostatic pressure, electric and electromagnetic fields, and pressure waves, for example, high-pressure processing (also in combination with heat), microwave processing, ohmic heating, pulsed electric field (PEF) processing, ultrasound processing (liquid and airborne), and ultraviolet light (UV) processing. Innovative processing technologies present a number of hurdles that need to be addressed from
concept development to implementation. In particular, proper application, development, and optimization of suitable equipment and process conditions require a significant amount of further knowledge and understanding. In this book, the basic principles, current research, challenges, and commercial applications of the respective technologies, as well as the development and application of computational fluid dynamics (CFD) and, more broadly, Multiphysics modeling as a tool for characterizing, improving, and optimizing innovative food processing technologies are covered. Most innovative processing technologies have a common challenge, that is, to achieve a sufficient uniformity of the treatment or the process. This challenge is often already an issue at laboratory scale and it can become progressively worse when scaling up to pilot plants and, subsequently, to commercial equipment. Among other potential technologyspecific issues, nonuniformity of the treatment is most commonly encountered. In fact, the nonuniformities of the process and the lack of process validation of innovative processes are the greatest limitations for industrial uptake. Nonuniform treatment is, however, not specific to innovative processing technologies; conventional
Innovative Food Processing Technologies: Advances in Multiphysics Simulation, First Edition. Edited by Kai Knoerzer, Pablo Juliano, Peter Roupas, and Cornelis Versteeg. © 2011 by John Wiley & Sons, Ltd. and Institute of Food Technologists. Published by John Wiley & Sons, Ltd. ISBN: 978-0-813-81754-5
3
4
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
processing technologies often encounter the same problem. For example, in conventional heat treatment processes such as canning, the temperature at the product surface is significantly higher than at the product center during most of the processing time, and only after prolonged holding times are temperature gradients throughout the product diminished. Another clear example of nonuniformity in conventional processing is the drying process of particulates. In this case, spatial and temporal heterogeneities in temperature and water content in the food product can be even more pronounced. The product goes (1) through an initial linear drying phase with water removal from the product surface, (2) over the falling rate period with moisture flux from the inside of the product to its surface, and (3) to a stage of product and drying medium (moisture) equilibrium with almost no further change in water content. In drying food products other important factors often come into play, increasing the degree of nonuniformity: product shrinkage and reduced moisture transport (increasing viscosity of contained liquids) up to a stage where pores are blocked. In the case of many innovative processing technologies as described throughout this book, nonuniformities may be reduced through technology-specific effects. However, these nonuniformities may be more pronounced due to increased complexities influenced by additional Multiphysics phenomena. This introductory chapter outlines the range of innovative food processing technologies covered in this book and gives a short overview of their benefits and advantages over traditional technologies. Some additional background information on the technologies, not covered in the respective technologyspecific chapters, is provided. Furthermore, this chapter makes a case for the need for applying Multiphysics modeling in these technologies for their design, including scale-up and optimization. The chapter summarizes the problems and challenges faced by the modelers, particularly with respect to the prediction of temperature, flow and technology-specific field distributions (e.g., sound intensity and electric or electromagnetic fields), and the extent of microbial or enzymatic inactivation and their distribution in equipment and products.
1.2. Multiphysics Modeling 1.2.1. Definition Multiphysics modeling is an extension of classical CFD. By definition, CFD is one of the branches of fluid mechanics that uses numerical methods and algorithms to solve and analyze problems that involve fluid flows. The geometry of the modeled scenario, including all components, is discretized into finite cells on which the governing partial differential equations (PDEs), namely the continuity, momentum, and energy conservation equations, are solved. This is detailed in the chapters specific to the respective technologies. Because these are PDEs, they cannot be solved analytically. Numerical techniques, such as finite differences, finite volumes, or finite element methods, must be applied to achieve an approximated solution (Sun 2007). Multiphysics modeling is based on the same principles as conventional CFD, that is, geometry discretization, and solving the PDEs is performed in a similar manner. However, Multiphysics modeling comprises additional physical phenomena such as electromagnetic waves, electrical fields, and acoustic waves related to the innovative technologies discussed further in this chapter. These phenomena can also be described by physically based PDEs (specific to each innovative technology), which have to be solved simultaneously with the ones from classical CFD. In some cases, the expression of the process outcome based on the attributes of the processed food, that is, the remaining microbial load, enzyme activity, and chemical reaction products, is required. Within Multiphysics modeling, reaction kinetics (i.e., microbial inactivation, quality degradation, chemical reaction, and structural responses) can be coupled with the specific differential equations to provide the spatial distributions of reaction response. Multiphysics models that concurrently solve the PDEs of classical CFD and the additional technologyspecific physical phenomena and the differential equations describing the reaction response require significantly greater computational resources. The increase in affordable computational power in recent years has allowed the simulation of innovative processes.
Chapter 1
Introduction to Innovative Food Processing Technologies
5
Figure 1.1. Number of commercial high-pressure equipment units around the world as of 2009 (Tonello 2010).
1.3. Innovative Food Processing Technologies 1.3.1. Background This section presents a brief description of each technology covered in this book. The major design problems and application limitations of these technologies are highlighted as an introduction to subsequent chapters. Ways in which Multiphysics modeling of innovative food processing technologies can assist in their development will be discussed. 1.3.1.1. High-Pressure Processing (HPP) and High-Pressure Thermal Sterilization (HPTS) HPP has demonstrated wide applicability for producing high-quality foods. HPP has become accepted as an attractive alternative to traditional preservation methods utilizing preservatives or thermal processing (Hernando Saiz et al. 2008, Chapters 3–5). HPP is commonly referred to as a nonthermal process of liquid and solid foods through application of high pressure in the order of 100–800 MPa (1,000 to 8,000 bar) and holding times of several minutes. HPP of foods is of increasing interest because it allows the inactivation of vegetative organisms at low or moderate temperature with minimum degradation (Abdul Ghani and Farid 2007). HPP offers opportunities for increased shelf life and preservative-free stabilization of meats, seafood, vegetable products, and juices. HPP can be
used not only for preservation, but also for modifying the physical and functional properties of some foods. More than 70 companies currently utilize HPP, producing more than 170,000 tons of products (Tonello 2010). Several HPP-treated food products, including juices, jams, jellies, yogurts, ready-to-eat meat, and oysters, are already widely available in the United States, Europe, Japan, New Zealand, and Australia. These successful applications have led to a pronounced increase in commercial-scale HPP units around the world during the past 10 years, as shown in Figure 1.1. In addition to inactivation of microorganisms and some spoilage enzymes (Seyderhelm et al. 1996; Yen and Lin 1996), promising results have been obtained with respect to the application on gelation of food proteins (Ohshima et al. 1993), improvement of digestibility of proteins, and tenderization of meat products (Ohmori et al. 1991; Jung et al. 2000a, 2000b; Buckow et al. 2010b). These changes in proteins have been used successfully in fish meat; in Carpaccio and Carpaccio-like products, high pressure allows the “processing” of the product, while still maintaining its raw characteristics. However, because of the application of high pressures, these products have retained “fresh-like” qualities and texture compared with heat-processed food, are microbiologically safe, and have an extended shelf life compared with raw food. Gomez-Estaca et al.
6
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
(2009) investigated HPP on fish products (such as salmon, tuna, and cod), showing superior sensory results. If the aim of the process is the inactivation of microbial spores, high pressure alone is not sufficient. However, a combination of high pressure and elevated temperatures, also referred to as HPTS or pressure-assisted thermal sterilization, can result in synergistic inactivation of these spores at potentially lower temperatures or shorter processing times, thus improving the quality of the processed foods while potentially reducing energy consumption (Bull et al. 2009). In this application, the increase in pressure is used as a means to increase the temperature evenly and fast in the product. There are two approaches to achieve highpressure conditions. In the direct approach, a piston is utilized, which compresses the content of the high-pressure chamber. In the indirect approach, a pressure-transmitting liquid (e.g., water) is pumped into the treatment chamber (high-pressure vessel) using a high-pressure pump followed by a “pressure intensifier.” Liquids at extremely high pressures are compressible, requiring extra fluid to be pumped into the vessel. During compression, the temperature of the processed food and the pressure-transmitting fluid increases due to the compression force working against intermolecular forces. The magnitude of the adiabatic temperature increase depends on a number of factors, such as the pressure medium and food product thermophysical properties (density, thermal expansion coefficient, and specific heat capacity) and initial temperature (see, e.g., Chapters 2, 4, and 5). Higher fat content of the food and higher initial temperature, for example, lead to an increase in compression heating. The phenomenon of increasing compression heating at elevated initial temperatures is important; for example, in HPTS, the product and the pressure medium are preheated to achieve higher process temperatures, which in turn allows inactivation of microbial spores (Wilson et al. 2008). In HPP, the greater the pressure level and time of application, the greater the potential for changes in the structure and appearance of the treated foods. This is especially true for raw high-protein foods,
where pressure-induced protein denaturation may be visually evident. High pressures can also induce significant structural changes (or damages) in some sensitive foods, such as strawberries or lettuce. Cell deformation and cell membrane damage can result in softening and cell serum loss. Usually, these changes are undesirable because the food will appear to be processed and no longer fresh or raw. Limitations of HPP and HPTS Although great progress has been made in the development of economically viable high-pressure applications, the scientific community and the food industry recognized in the early 2000s that engineering fundamentals, including CFD models, were required to design, evaluate, optimize, and scale up high-pressure processes of foods (Hendrickx and Knorr 2001). The limitation of HPP to date mainly lies in the limited throughput and, relative to heat processing, the high cost of equipment, labor (HPP is not yet a fully automated process), and maintenance. High maintenance costs are caused mainly by the extreme processing conditions. Furthermore, there are only a few large-scale commercial high-pressure equipment suppliers worldwide that have expertise in the food industry, including Avure Technologies, Inc. (Kent, WA), Kobelco (Kobe Steel Ltd., Kobe, Japan), and NC Hyperbaric (Burgos, Spain). A common issue in both HPP and HPTS is the nonuniformity of some aspects of the treatment. HPP generates pressure waves in liquids, which travel at the speed of sound (sound in water travels at 1,500 m/s). Therefore, pressure is commonly assumed to be transmitted instantaneously and uniformly. However, treatment nonuniformities can occur during HPP not only as a result of different compressibilities of the various substances in the food product, including trapped air (also headspace), but also because of the food packaging material. In addition, if the purpose of the process is the inactivation of the vegetative microorganisms, a nonuniform treatment can occur because some microorganisms are supposedly more resistant to the pressure when embedded in a fat matrix. Foods with higher fat or oil content may, therefore, protect the microorganisms in some areas in the food where fat is contained.
Chapter 1
Introduction to Innovative Food Processing Technologies
In the case of processing above room temperature (initial temperature), for example, in HPTS, nonuniform treatment temperature is likely to be more pronounced. In addition to pressure, temperature is an important process variable. In heterogeneous food materials, with the contents exhibiting differences in compression heating, temperatures may not be uniformly distributed in the food products. Furthermore, the packaging material, the material of the product carrier, and the steel of the high-pressure vessel are not heated to the same extent as the food; therefore, temperature gradients are developed throughout the system, leading to heat flux from the products to the cooler areas (which are mainly the steel walls). These spatial temperature heterogeneities increase over the process time. Although, theoretically, the preheated product heats up uniformly during compression to sterilization temperatures, during pressure holding time temperatures may decrease in certain areas of the vessel. This can affect spore inactivation, and spores may survive the process if temperature loss is not prevented. Product carriers have been developed as a means of retaining heat throughout the vessel during both pressure come-up and holding times (Chapter 5). Multiphysics modeling can greatly assist in the characterization of temperature distribution, subsequent microbial distributions, and other quality changes as a result of temperature inhomogeneities. These models can also be applied to the redesign and optimization of equipment and determination of adequate processing conditions for optimum process/product performance. 1.3.1.2. Microwave and Radio Frequency Processing Microwave heating refers to the use of electromagnetic waves of certain frequencies to generate heat in a material (Metaxas and Meredith 1983; Roussy and Pearce 1995; Metaxas 1996). Typically, microwave food processing uses frequencies of 2,450 and 915 MHz. In domestic ovens, 2,450 MHz frequency is commonly utilized, while in industrial heating application both frequencies are used, depending on the product to be treated, that is, product size and composition, associated with the relevant thermophysical properties (Chapters 2, 6, and 7).
7
Microwave heating has been proposed as an alternative to traditional heating methods in many food manufacturing processes, such as (re)heating, baking, (pre)cooking, tempering of frozen food, blanching, pasteurization, sterilization, and dehydration (Metaxas and Meredith 1983; Decareau 1985; Buffler 1993; Metaxas 1996; Schubert and Regier 2005; Tang et al. 2008). Microwave and radio frequency heating for pasteurization and sterilization are rapid; therefore, less time is required for come-up to the desired process temperature compared with conventional heating. This is particularly true for solid and semisolid foods that depend on slow thermal diffusion process in conventional heating. Microwave and radio frequency heating can approach the benefits of hightemperature short-time (HTST) processing, whereby bacterial destruction is achieved, while thermal degradation of the desired components is reduced. Heating with microwaves primarily involves two mechanisms. Water in the food is often the main component responsible for dielectric heating. Due to their dipolar nature, water molecules follow the alternating electric field associated with electromagnetic radiation. The second major mechanism is through the oscillatory migration of ions in the food under the influence of the alternating electric field. Such oscillatory motion of water molecules and ions and the associated intermolecular friction lead to a conversion of electromagnetic energy to thermal energy. The dielectric properties, namely the dielectric constant and the loss factor (Chapter 2), determine the strength of the electric field inside the food and its conversion into heat. These properties strongly depend on the composition (or formulation) of the food, with moisture and salt being the two primary determinants of interest (Mudgett 1985, 1986; Sun et al. 1995; Nelson and Datta 2001). The subsequent temperature rise in the food depends on the duration of heating, the location in the food, convective heat transfer at the surface, and the heat conduction and extent of evaporation of water inside the food and at its surface. Although the final objective of each process differs, an increase in product temperature is seen as
8
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
a common theme. There has also been some speculation on the so-called nonthermal effects of electromagnetic waves in the microwave frequency range. Four theories have been proposed to explain “nonthermal” or nondirect thermal effects of microwaves on, for example, microorganisms: selective heating, electroporation, cell membrane rupture, and magnetic field coupling (Kozempel et al. 1998). The selective heating theory states that solid microorganisms are heated more effectively by microwaves than the surrounding medium and are thus killed more readily. Electroporation is caused when pores form in the membrane of the microorganisms due to electrical potential across the membrane, resulting in leakage (this is similar to one of the theories on the effect of PEF processing for cold pasteurization). Cell membrane rupture is related to the voltage drop across the membrane, which causes it to rupture, which is also a theory in PEF processing. In the fourth theory, cell lysis occurs due to coupling of electromagnetic energy with critical molecules within the cells, disrupting vitally important internal cell components. Although researchers have repeatedly reported nonthermal effects of microwave processing, the general consensus (Heddleson and Doores 1994; Heddleson et al. 1994) is that the reported nonthermal effects are likely to be due to the lack of precise measurements of the time–temperature history and its spatial variations. A number of studies have shown that thermal effect is the essential contributor to the destruction of microorganisms (Goldblit and Wang 1967; Rosen 1972; Fujikawa et al. 1992). Therefore, to date, it is presumed that only thermal effects on microbial inactivation are effective, and microbial inactivation caused by microwave processing is essentially the same as in conventional thermal processing. Of course, the rates of heating and temperature distributions are quite different. Limitations of Electromagnetic Heating Volumetric microwave and radio frequency heating is theoretically more uniform than conventional heating (Datta and Hu 1992). There are, however, a number of microwave-specific factors that induce nonuniform heating patterns. First, electromagnetic field distribution inside a microwave cavity is, in most cases, not
uniform. Placing dielectrics (i.e., food products) into the microwave field leads to a change in the field distribution. Therefore, differences in the products, for example, product size, shape, and particularly composition with varying dielectric properties, will almost certainly lead to changes in process outcomes. However, not only do the field variations in the cavity cause nonuniform processing, the field characteristics inside the product are also heterogeneous. The heterogeneous composition of the different food components (and different dielectric properties) is an important factor in the heating of foods. Differences in dielectric properties lead to differences in temperature increases, even in a perfectly homogeneous microwave field. As these properties are in most cases strongly temperature-dependent, changes in temperature may compensate or may increase the nonuniformity. In particular, in cases where increasing temperatures lead to increasing loss factors (the imaginary part of the complex dielectric permittivity; Chapter 2), a so-called thermal “runaway” phenomenon can occur. With increasing temperature the rate of converting the electromagnetic energy into thermal energy increases as well; therefore, the gradients between hot and cold areas in the product become more pronounced. Another important factor in heating is the socalled focusing effect of the microwaves into specific areas in the product. This phenomenon is strongly dependent on the geometrical properties of the product. For example, a spherical product that does not exceed a certain size (due to limited penetration) can exhibit a pronounced hot spot in its geometrical center. Other phenomena causing uneven heating patterns include edge and corner overheating (caused by the penetration and absorption of the microwaves from more than one direction) and the development of standing waves inside the product (which is mainly dependent on the dielectric constant (the real part of the complex dielectric permittivity; Chapter 2). The time–temperature history at the coldest point for a conventional thermal process is generally predictable for a food that is all solid or all fluid. For example, for a conduction-heated (solid) food, it is usually the geometric center. In microwave heating,
Chapter 1
Introduction to Innovative Food Processing Technologies
even for a solid food, it is less straightforward to predict the coldest point and it can change during the heating process depending on temperaturedependent material properties and oven characteristics (Fleischman 1996; Zhang et al. 2001). A number of approaches have been proposed to improve the uniformity associated with microwave heating. These include rotating and oscillating the food in the microwave cavity (Geedipalli et al. 2007), providing an absorbing medium (such as hot water) surrounding the product (Chen et al. 2008; Chapter 6), equilibrating after heating (Fakhouri and Ramaswamy 1993), and cycling the power (Chapter 7). Success to date is limited due to the dependence of the materials’ properties on temperature and the nonuniform distribution of the electromagnetic field inside the food and the microwave cavity. Utilizing a lower microwave frequency of 915 MHz and radio frequencies to improve uniformity of heating have the potential to improve the evenness of heating (Chen et al. 2008), as the penetration depth into the food is greater and the field nonuniformities are less pronounced. Combinations of microwave and conventional technologies in many different configurations (e.g., hot air, vacuum, or infrared heating) have also been used to improve treatment uniformity; (Contreras et al. 2008; Turabi et al. 2008; Abbasi and Azari 2009; Kowalski and Mierzwa 2009; Kowalski and Rajewska 2009; Seyhun et al. 2009; Uysal et al. 2009). These approaches can be successful for some applications, especially where the cold spot is located at the food surface (Chapter 7); however, in food products with high salt or sugar content, the cold spot is usually within in the food, as the penetration depth of the electromagnetic waves is reduced. It remains a challenge to uniformly treat food products with microwaves and to achieve the targeted process outcomes; Multiphysics models, however, will greatly assist in designing microwave processes by evaluating process performance and developing appropriate control strategies (Chapters 6 and 7). Accordingly, Multiphysics models (including temperature-dependent properties of foods) need to be developed and subsequently validated to ascertain the location of the point of lowest integrated time–temperature history (Chapter 7).
9
1.3.1.3. Ohmic Heating Ohmic heating is defined as a process wherein electric currents are passed through foods or other materials with the primary purpose of heating them. The heating occurs in the form of internal electric energy dissipation within the material. Ohmic heating is distinguished from other electrical heating methods by the presence of electrodes contacting the food, the frequency of the current, or the waveform. The main purpose for the development of ohmic heating processes was to allow for HTST sterilization of solid–liquid mixtures (Chapter 8). Applications of ohmic heating in the food industry to date are scarce, although there are a number of advantages over other (conventional) heating methods. The main advantages for ohmic heating are the associated rapid and relatively uniform heating of the food product, depending on the electrical conductivity of the food components. This is expected to reduce unwanted thermal effects on the product that often occur in conventional heating applications, caused by the need to heat the product by the transfer of thermal energy from a heating medium to a low temperature product, where excessive treatment times are necessary for sufficient heat penetration from the surface of a solid product to its core. Potential applications for ohmic heating include its use in blanching, evaporation, dehydration, fermentation, and extraction. At present, the primary type of application is a heat treatment for microbial control, for example, for the pasteurization of milk, and also for processing of sauces, fruits, and tomatoes (Chapter 8). The principal mechanisms of microbial inactivation in ohmic heating are thermal in nature. Recent literature, however, indicates that a mild electroporation mechanism may occur during ohmic heating (similar to the effects utilized in PEF processing (Lebovka et al. 2005; Kulshrestha and Sastry 2006). The principal reason for the additional microbial inactivation effect to heating of ohmic treatment may be its low frequency (50–60 Hz), which allows cell walls to build up charges and form pores. This is in contrast to high-frequency methods such as microwave or radio frequency heating,
10
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
where the electric field is essentially reversed before sufficient charge buildup occurs at the cell walls. Nevertheless, temperature is the principal critical process factor in ohmic heating. As in conventional thermal processes, the key issue is identifying the slowest heating zone. Fundamentally, there is only one critical factor: the temperature–time history of the coldest point. Since the primary critical process factor is the thermal history and location of the cold spot, the effects on microbial inactivation are the same as for thermal processes. Locating the slowest heating zones during ohmic heating, however, cannot be extrapolated from current knowledge of conventional heating, and requires special consideration. Several factors significantly affect the temperature within an ohmic process. The critical parameters in continuous flow ohmic heating systems include electrical conductivities of the respective phases of the food, temperature dependence of the electrical conductivity, design of the heating device (e.g., location and orientation of the electrodes), extent of interstitial fluid motion, residence time distribution, thermal properties of the food, and electric field strength (Chapter 8). Limitations of Ohmic Heating The main limitation of ohmic heating is the heterogeneous nature (in composition) of the food products and their corresponding electrical conductivities that leads to differences in the conversion of the electrical current into thermal energy. As in microwave heating, in ohmic heating, thermal runaway can also occur, because electrical conductivity, which is the property that influences electrical energy dissipation, usually increases with increasing temperature. Therefore, especially in stationary (i.e., not moving in a stream) solid products, there may be areas that are very hot (usually areas close to the electrodes), which in some instances may even be burned, while in other areas (with initially lower electrical conductivities, or farther away from the electrodes) almost no heating occurs. Uniform heating with ohmic processing is theoretically possible, but at the same time challenging due to the various factors impacting on the slowest heating zone and the time–temperature history
throughout the product. Multiphysics modeling (including the temperature-dependent properties of the foods: mainly the electrical conductivity) can greatly assist the evaluation and optimization of ohmic heating systems to achieve heating uniformity (Chapter 8). 1.3.1.4. PEF PEF processing is an innovative nonthermal processing technology mainly for liquid and pumpable foods (including emulsions, suspensions, and semisolids such as sausage meat), predominantly used for the inactivation of microorganisms at ambient or mild temperatures, thereby preserving the fresh flavor, color, functional properties, and integrity of heat-sensitive compounds (Chapters 9–11). PEF can also be used to enhance extraction yield of juices and bioactives from plant sources. PEF is one of the most appealing nonthermal technologies for preservation of liquid foods due to reduced heating effects compared with traditional pasteurization methods (Barbosa-Cánovas et al. 1999). In PEF processing, a liquid or other pumpable material is passed through an electrode arrangement where the PEF is applied. For microbial inactivation, foods are processed by means of brief pulses of a strong electric field with field strengths of around 15–40 kV/cm. For extraction of plant materials and pretreatment of meat for processing, only about 0.7 to 3 kV/cm is required (Toepfl et al. 2006). The utilization of PEF leads to the formation of pores (the so-called electroporation [temporary or permanent]), in the membranes of microbial or plant cells, which disturbs and damages the membrane’s functionality, leading to inactivation of the cells and the partial release of the cell contents to make extraction or other processing more efficient. Membrane disruption occurs when the induced membrane potential exceeds a critical value of 1 V in many cellular systems, which, for example, corresponds to an external electric field of about 10 kV/ cm for Escherichia coli (Castro et al. 1993). The most relevant factor affecting microbial inactivation and extraction enhancement by PEF is, therefore, the electric field intensity. The combination of electric field intensity, total treatment time during PEF and pulse shapes, and the associated temperature
Chapter 1
Introduction to Innovative Food Processing Technologies
increase determine the extent of membrane disruption in bacterial and plant cells (Hamilton and Sale 1967). Other factors affecting the performance of the PEF process include the microbial entity to be inactivated (type, concentration, and growth stage of microorganism) and the treatment media (pH, antimicrobials, and ionic compounds, electric conductivity, and medium ionic strength). PEF produces products with slightly different properties from conventional pasteurization treatments. Most enzymes are not affected by PEF. The fact that the maximum temperature reached is lower than in thermal pasteurization means that some of the flavors associated with the raw material are not destroyed. Spores, with their tough protective coats, and dehydrated cells are mostly able to survive PEF processing. The survival of spores and enzymes means that products have to be refrigerated after passing through PEF processing in order to slow the action of the enzymes and keep pathogens from growing; PEF alone is generally not capable of producing ambient shelf-stable products. However, acidic well-packaged products may have a useful ambient shelf life. As indicated before, another potential application of PEF, which is gaining increasing interest, is the utilization of the technology for enhanced extraction of plant cell material. Because PEF induces electroporation in cell walls at relatively low energy inputs, allowing the cell contents to leak out, it holds promise as an efficient way of getting useful components out of cells and cell membranes (Corrales et al. 2008; Lopez et al. 2009a, 2009b; Loginova et al. 2010; Puertolas et al. 2010). To date, however, PEF has been mainly researched to preserve the quality of foods, such as to improve the shelf life of orange juice, apple juice, milk, and liquid eggs, as well as the fermentation properties of brewer ’s yeast. Martín-Belloso and SolivaFortuny (2010) have summarized the work of several researchers on food-borne pathogenic microorganisms in different food products. Limitations of PEF Processing Issues that may arise with PEF include electric arcing, dielectric breakdown of the treated food, and a pronounced
11
temperature increase (caused by ohmic heating). Several factors play a role here, including the material’s electrical conductivity, the frequency of the pulses, their duration (width), adequacy of deaeration, back pressure, and the flow rate of the liquid (laminar or turbulent flow regime; residence time in the treatment chamber). Because the pulse duration is only in the range of microseconds and, therefore, the overall treatment time is short, temperature increases during treatment are often assumed to be minimal and temperature effects neglected in inactivation studies. In processing liquids with PEF, a nonuniformity of the treatment can be a result of the interaction between the flow, heat transfer, electric field phenomena, and effects on microbial or plant cells. Predictions of the increase in temperature caused by the electric field are similar to ohmic heating and less complicated compared with the dissipation of electromagnetic energy in microwave processing. Moreover, the property influencing this dissipation effect, that is, the electrical conductivity, is easier to measure, and usually shows a less complex behavior with temperature than the two dielectric properties in microwave processing, that is, the dielectric constant and the loss factor (Chapter 2). However, the purpose of the pulsed (potentially alternating) electric field is, unlike in microwave processing, not an increase in temperature. The temperature increase should be minimized in most PEF applications. The main aim is a nonthermal inactivation of vegetative microorganisms for cold pasteurization or a nonmechanical means of opening cells for enhanced extraction. In particular, for the purpose of cold pasteurization, a great degree of electric field uniformity is needed to ensure a similar treatment of the entire liquid product. Ideally, the same number of electric pulses and electric field strength is applied to all microorganisms present in the liquid. Typically, pasteurization requires inactivation of up to 99.999%, that is, 5 log of the target organism. If only a small fraction of microorganisms bypass proper treatment through regions of low electric field strength, it is not possible to reach the required extent of inactivation.
12
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Achieving this uniformity, however, is very challenging; the electric field distribution is strongly dependent on the configuration of the treatment chamber (and to a lesser extent on the electrical conductivity and other thermophysical properties of the processed media). PEF chamber designs such as co-field, coaxial, or colinear electrode arrangements (Chapters 9–11) exhibit pronounced nonuniformities in flow, temperature, and electric field distributions. Uniform fields can be achieved in parallel plate configurations, which are mainly applied for batch processing. If the field is not uniform, the induced temperature increase is also uneven across the volume of the treatment chamber. Often, several treatment cells are arranged to process in series, which reduces the effects of imperfections in single treatment cells. Thus, in processes for inactivation of specific microorganisms that show synergistic effects of temperature and electric field on inactivation, temperature nonuniformities will lower the performance of the process. Nonuniformities can be minimized, but to some extent will always occur. To enable a comparable treatment history of the entire product, the flow pattern is very important. Laminar flow conditions, which can be found in low-throughput laboratory-scale systems, are to be avoided. In laminar flow, each microorganism follows a more or less straight path through the treatment chamber; therefore, pronounced differences in exposure to varying electric field strengths and temperatures will occur. Modifying the treatment chamber with grids (Chapter 10) or increasing the flow rate to give turbulent flow (Buckow et al. 2010a) can improve the uniformity of exposure of the product to the important treatment variables (e.g., temperature and electric field strength) and furthermore improve temperature uniformity due to increased (turbulent) thermal conduction and convective flows. For characterizing process performance, information on the field distributions is essential. However, such local information inside the chambers is difficult and near to impossible to obtain experimentally. For further development of the PEF technology,
numerical simulations can be applied to improve the fundamental understanding of the physical phenomena in the process and to optimize it with respect to the chamber design and operating conditions (Gerlach et al. 2008; Chapters 9–11). 1.3.1.5. Ultrasound Processing This technology is based on pressure waves at frequencies exceeding 20 kHz, that is, more than 20,000 vibrations per second. It is considered as another innovative process that has been investigated for many different purposes over the last decades. While in the earlier work mainly the lower frequencies of around 20 kHz were studied, research and applications currently include frequencies of several hundred kHz, to several MHz (Chapter 12). Ultrasound systems consist of a generator for turning electrical energy into high-frequency alternating current, a transducer for converting the alternating current into mechanical vibrations, and a delivery probe for conveying the sonic vibrations into a medium to couple sonic vibrations to the treated material. The transducers may take the shape of a rod, plate, bar, or sphere, and are usually manufactured from titanium, aluminum, or steel. The ultrasonic transducer can be mounted outside on the wall of a vessel or flow cell and be in indirect contact with foods, or it can be inserted into a treatment chamber or flow cell of specified geometry to transmit energy directly into a food system with better energy efficiency (Feng and Yang 2005). There are also transducers that are designed for effective transmission into air (Chapter 13). Ultrasound has attracted considerable interest in the food industry due to its useful effects in food structure modification (e.g., emulsification, extraction, crystallization, and viscosity alteration), food preservation, and enzyme modulation (Patist and Bates 2008). As one of the innovative and advanced food processing technologies, it can be applied to develop gentle but targeted processes to improve the quality and safety of processed foods and, thus, offers the potential for improving existing processes as well as for developing new process options.
Chapter 1
Introduction to Innovative Food Processing Technologies
Ultrasound alone has some effects on the inactivation of vegetative organisms in liquid food products. The bactericidal effect of ultrasound is generally attributed to intracellular cavitation (Hughes and Nyborg 1962). It is proposed that micro-mechanical shocks and jet streaming are created by microscopic cavitation bubbles induced by the fluctuating pressures under the ultrasonication process (Chapter 12). These shocks and microjets disrupt cellular structural and functional components up to the point of cell lysis. Positive effects have been observed when ultrasound is used in combination with temperature (thermo-sonication) or pressure (mano-sonication) or both (mano-thermo-sonication) in the inactivation of pathogenic bacteria, spoilage microorganisms, and enzymes (Cameron et al. 2009; Demirdoven and Baysal 2009; Lee et al. 2009). The use of temperature and ultrasound together has been successful in reducing the enzymatic activity in some target products such as juices, providing better stability during storage (Terefe et al. 2009). Sonicated milk is the most explored product; it shows positive results in pasteurization standards, better homogenization and color, as well as new physical properties for the development of dairy products (Chouliara et al. 2010). Most developments of ultrasound for food applications are nonmicrobial in nature, that is, their main aim is not inactivation of microorganisms (Hoover 1997). High frequencies in the range of 0.1 to 20 MHz, pulsed operation, and low power levels (100 mW) are used for nondestructive testing (Gunasekaran and Ay 1994). These industrial applications include texture, viscosity, and concentration measurements of many solid and fluid foods; composition determination of eggs, meats, fruits and vegetables, dairy, and other products; thickness, flow level, and temperature measurements for monitoring and control of several processes; and nondestructive inspection of egg shells and food packages. Apart from testing applications, process improvements have been observed in applications such as cleaning surfaces (Tolvanen et al. 2009), enhance-
13
ment of dewatering, drying and filtration, inactivation of microorganisms and enzymes, disruption of cells, degassing of liquids, emulsification, accelerating heat transfer and extraction processes (Patist and Bates 2008; Vilkhu et al. 2008), enhancement of processes dependent on diffusion (e.g., enzyme activity, targeted infusion of small compounds into porous food matrices), and also targeted movement of two-phase systems, such as oil droplets or particles dispersed in a continuous aqueous phase (Doblhoffdier et al. 1994; Hawkes et al. 1997; Groschl 1998). It is evident that ultrasound technology has a wide range of actual and future applications in the food industry. More recently, research activities related to the sonochemistry in certain foods products have gained interest, involving the reactions that ultrasound generates in food during processing. Jambrak et al. (2009) show that these chemical reactions can be used to generate new compounds in food for specific purposes such as the modification of proteins. Hydroxylation of phenolic compounds to enhance their antioxidant properties has also been studied by Ashokkumar et al. (2008). Another interesting application is the use of airborne ultrasound for enhanced drying of food products. Difficulties in the propagation of ultrasound waves in air and the impedance mismatch at the transducer/air interface have led to the development of especially adapted transducers that have been applied, for example, to drying of carrots, lemon peel, and other food products (Garcia-Perez et al. 2009; Chapter 13). Limitations of Ultrasound Processing Although potential applications of ultrasound processing are many and diverse, the uptake by industry to date is not widespread. Reasons for this include a lack of knowledge of ultrasound intensity distribution in tank systems and, particularly, in flow-through systems, where the forced convection disturbs the ultrasound field, as well as the effect of the pressure waves on the food product. Depending on the equipment, with the generators, the transducers, treatment cells, the frequency and power of the ultrasound
14
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
waves, and the product properties, the effect of ultrasound can differ significantly. Ultrasound processing comprises another Multiphysics phenomenon: the acoustic field. Several factors must be considered, for example, ultrasound frequency, intensity, the associated speed of sound and sound absorption, and impact on the acoustic field. Although the speed of sound in a homogeneous medium is independent of the sound wave frequency and intensity, varying composition of the treated product strongly impacts the speed. The sound absorption is dependent on the composition as well as the frequency and intensity of the ultrasound waves. In addition to this, occurring cavitation (Chapter 12) significantly influences the speed of sound, the sound absorption and, therefore, the acoustic field distribution. The speed of sound in a cavitating medium can, for example, decrease from a value of 1,500 m/s to values as low as 20 m/s. As discussed in Chapter 12, the ultrasound waves in a cavitating medium can be completely absorbed by the cavitation bubbles in the close vicinity of the ultrasound transducer and, therefore, large parts of the sonoreactors may not undergo ultrasound treatment. Although this pronounced absorption leads to the conversion of the sound energy into motion and the formation of a turbulent jet, which could in turn result in the treated liquid being well-mixed and, therefore, undergoing a similar treatment over time, the presence of solid products, which due to size and different densities cannot completely follow the flow, may induce further treatment nonuniformity. During ultrasound processing, standing waves (the so-called bands) can occur. This formation of bands can be an intended desirable effect, for example, for separating multiphase products such as emulsions. In other cases, where the sound waves are meant to induce other effects, such as cell disruption, sono- or biochemical reaction, the standing waves can unintentionally impair the process performance. Hence, generic Multiphysics models, including acoustics, heat and fluid flow and, potentially, coupling to the kinetics of food transformation, enhanced diffusion, microbial interaction, and enzyme modulation need to be developed. Such models can assist
in process design, scale-up and optimization and subsequent uptake of the technology by the food industry.
1.3.1.6. UV Processing UV light for food processing has been investigated for many years but is still considered as an innovative technology in food processing. In this technology, UV-C light (wavelength of 254 nm) is predominantly being used as a disinfection method to inhibit or inactivate foodborne microorganisms, mainly in liquid food products (Chapters 14 and 15). Fresh produce can be processed using UV light, which has a germicidal effect on many types of microorganisms (bacteria, viruses, protozoa, molds, and yeasts). However, the effect of UV light on microorganisms in liquids depends on variables such as density of the liquid, types of microorganisms, UV-C absorptivity of the liquid, and the solids (suspended or soluble) in the liquid. Although the use of UV light is well established for air and water treatment and surface decontamination, its use for treating liquid foods is still limited. Recently, interest in using UV has increased as a viable alternative to thermal pasteurization for a range of liquid foods and ingredients (fresh juices, fruit purees, soft drinks, raw milk, liquid eggs, liquid sugars and sweeteners, etc.) (Koutchma 2009). Pumpable fruit and vegetable products are generally very suitable for processing by UV light to reduce the microbial load (Guerrero-Beltran and BarbosaCánovas 2004) as long as sufficient fluid mixing allows the entire product to be exposed to a certain required dose of UV radiation. The germicidal properties of UV irradiation are mainly due to DNA damage induced through absorption of UV light by DNA molecules. This mechanism of inactivation results in a sigmoidal curve of microbial population reduction (Bolton 1999). UV treatment can be used for primary disinfection or as a backup for other purification methods such as carbon filtration, reverse osmosis, or pasteurization. As UV has no residual effect, the best position for a treatment system is immediately prior to the point of use. This ensures that any incoming microbiological
Chapter 1
Introduction to Innovative Food Processing Technologies
contaminants are destroyed and that there is little chance of post-treatment contamination. In addition to UV-C light, UV light with wavelengths other than 254 nm can also be used as a radiation source to inactivate microorganisms in foods (liquids or solids). In general, wavelengths ranging from 100 (UV-V, vacuum UV light) to 400 nm (UV-A) are suitable for UV light processing (Bintsis et al. 2000; Sastry et al. 2000). UV disinfection has many advantages over alternative methods. Unlike chemical treatment, UV does not introduce toxins or residues into the process and mostly does not alter the chemical composition, taste, odor, or pH of the water or liquid being disinfected. As a physical method, UV irradiation has a positive consumer image and is of interest to the food industry as a low-cost nonthermal method of preservation. Recent advances in the science and engineering of UV light irradiation have demonstrated that this technology holds considerable promise as an alternative method to traditional thermal pasteurization for liquid foods and ingredients, fresh juices, soft drinks, and beverages. Limitations of UV Processing Compared with water, liquid foods have a range of optical and physical properties, diverse chemical compositions, and solid-phase characteristics (particle size and size distribution, shape and volume fraction), influencing UV light transmittance (UVT), dose delivery, momentum transfer (laminar or turbulent flow), and consequently microbial inactivation (Koutchma 2009; Chapter 14). As there is no practical method for evaluating the spatially resolved performance experimentally and predictions of the process performance are not straightforward for liquid foods (compared with water), Multiphysics modeling is essential for evaluating particles and fluid velocities in the UV reactor, particle mixing, particle location, residence times, UV fluence rate (irradiance) distribution and resulting changes in bacterial count. As mentioned, UV is mainly useful for surface decontamination (e.g., on fresh produce) and for disinfection of liquids transparent to the UV light to a certain extent. Although consisting of electromagnetic waves, the penetration of UV light into opaque
15
substances is limited at these wavelengths. Therefore, microorganisms on the surface of products can be protected by the so-called shadowing effect, caused, for example, by overlapping parts of the products. Treating opaque liquids is impossible under laminar flow conditions as the product flowing through the center of a UV transparent glass tube will not “see” the UV light. Providing a highly turbulent flow, however, can allow sufficient treatment uniformity, as all particles will likely be close to the glass walls at least for a certain period of time. Residence time in such a flow reactor must be sufficiently long to ensure similar treatment histories of the entire liquid product. Multiphysics modeling can assist in the UV chamber design and optimizing process conditions according to the absorptivity and other properties of the fluid, while assuring a similar treatment history of all portions of the liquid or dispersion. In all technologies and their associated specific issues regarding nonuniformity discussed in the previous sections, Multiphysics modeling can assist in providing insights into the internal distribution of processes in treatment chambers and products. It can be utilized to improve the systems design, performance, optimization, and scale-up to commercial applications by reducing inhomogeneities and for the process to become acceptable and viable.
1.4. Modeling Challenges Previous sections have described a number of limitations encountered in innovative food processing technologies and how Multiphysics modeling can assist in overcoming them. However, there are practical complexities in modeling and validating models for these technologies that will be covered in this section.
1.4.1. Modeling Complexity in Innovative Processing As mentioned earlier in this chapter, modeling innovative processing involves additional physics phenomena to conventional CFD. This implies that the fundamental conservation equations from thermofluiddynamics need to be coupled with the PDEs to
16
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
describe the respective field phenomena (i.e., electromagnetic, electric, and acoustic fields), thereby providing considerably increased complexity. Developing a Multiphysics model requires the same steps as developing a CFD model (Sun 2007), for example, the geometry definition, where all objects in the model scenario are constructed and assembled in the modeling software package or imported from a computer-aided design (CAD) drawing of the system (treatment chamber, peripheral devices, piping, food, packages, etc.). In particular, the materials forming the complete computational domain (i.e., the processing system), commonly referred to as subdomains, may include solids, liquids, and gases. The next step is discretization, that is, approximating the computational domain by finite cells. Next, material specific thermophysical properties need to be allocated to each subdomain as functions of the process variables (e.g., temperature and pressure; Chapter 2) and initial conditions and boundary conditions need to be defined. Furthermore, the model needs to specify time dependency, whether they are transient or stationary. The main differences between conventional CFD and Multiphysics modeling are as follows: • The geometry discretization step often needs more details than in conventional CFD. For example, in electromagnetics modeling with the finite difference method 15 cubic cells per wavelength have been recommended (QWED Sp.z o.o. 2003). In microwave processing at 2.45 GHz, with a wavelength in vacuum of around 12 cm, the maximum mesh cell size should therefore be below 1 mm (edge length). Furthermore in modeling an acoustic field with the finite element method, the resolved three-dimensional (3D) mesh should have at least 12 degrees of freedom per wavelength for each possible direction of the wave (i.e., the degrees of freedom of the complete mesh in three dimensions should be 1,728 times the model volume in wavelengths). Higher frequencies, with shorter wavelengths, therefore, limit the feasible volume of the model scenario (COMSOL Multiphysics 2007). • As discussed in Chapter 2, there is a lack of thermophysical property data of foods, in particular
expressed as a function of the process variables needed for model accuracy. As will be shown, more properties are needed to model innovative processes than conventional processes. • Each boundary condition will have to be defined for each Multiphysics phenomenon as a requirement to solve PDEs at the interface of each subdomain. • In most cases, when relatively high frequencies are involved (PEF, ultrasonic processing, ohmic heating, microwave, UV), time resolution of the respective waves is not feasible due to the short time scales (i.e., a higher frequency gives smaller time scales) across the domain. Therefore, an integrated value from the steady-state solution of the wave equation is often used as a source term in the conservation equations for momentum and energy. Multiphysics models are highly nonlinear mathematical problems. With each additional PDE, the degree of nonlinearity increases. Depending on the mesh, the thermophysical properties (as functions of the process variables), and the number of physics phenomena being coupled, the difficulty for convergence of the model may increase. When that is the case, models may not be as robust as those developed utilizing classical CFD PDEs.
1.4.2. Validation of Multiphysics Models Validation is an essential step to complete the modeling process. Models used for prediction of process variables and their distributions may converge, suggesting solutions that might be plausible, but in fact are not accurate (Nicolaï et al. 2001). Therefore, particularly in the case of highly nonlinear Multiphysics problems, the numerical solutions must always be validated before using them for further studies, such as equipment and process redesign, optimization, or scale-up. The validation process involves the comparison of predicted data (i.e., temperature, velocities, inactivation extent, and chemical or physical change) with measured data. This can be done using two approaches: (1) direct validation of process variables; or (2) indirect
Chapter 1
Introduction to Innovative Food Processing Technologies
17
Table 1.1. Tools for the validation of Multiphysics models. Technology High-pressure processing
Process variable or outcome to validate
Direct (D)/ Indirect (I)
Temperature
D I
Microwave, ohmic heating
Pulsed electric field (PEF)
Ultrasound
Ultraviolet (UV)
Method
Chapter or reference
Thermocouples, wireless temperature logger Enzymatic or other temperature time integrator (TTI), liquid crystals
Chapter 5
Fluid velocity
D
High-pressure PIV
Indicator
D/I
Temperature
D I
Fluid velocity Indicator
D D/I
Temperature
D
Indicator
I D/I
Enzymatic, microbial, colorimetric determination methods among others Thermocouples, fiber-optic probes MRI, infrared thermography, microwave radiometry, time temperature integrators, liquid crystals PIV (particle tagging), LDA Enzymatic, microbial, colorimetric determination methods among others Thermocouples (not in the area of high-electric field strength), fiber-optic probes Enzymatic TTI Enzymatic, microbial, colorimetric determination methods among others Thermocouples (type K) PIV, LDA Hydro- and microphones Qualitative visual (cavitation fields, band formation of particles), chemical markers Enzymatic, microbial, colorimetric, determination methods among others PIV, LDA Microbial (also referred to as biodosimetry), colorimetric, determination methods among others
Temperature Fluid velocity Acoustic intensity
D D D I
Indicator
D/I
Fluid velocity Indicator
D D/I
validation by means of a (bio)chemical or microbial indicator. Table 1.1 classifies the indirect and direct validation tools to determine the process variables or outcomes for each technology. Direct measurements include: • temperature measurements by utilizing resistance thermometers, thermocouples, or fiber-optic sensors • flow measurement by means of Laser Doppler Anemometry (LDA) or Particle Imaging Velocimetry (PIV)
(Pehl et al. 2000; Grauwet et al. 2010a, 2010b) (Pehl and Delgado 1999) (Denys et al. 2000) Chapters 7 and 8 Chapters 6–8
Chapter 8 Chapter 6 Chapter 10; (Buckow et al. 2010a) — Chapter 11 — Chapter 12 Chapter 13 (Klima et al. 2007; Sutkar and Gogate 2010) — (Hofman et al. 2007) Chapters 14, 15
• sound intensity by means of hydro- or microphones • particle (size) change by measuring particle size distribution, for example, with a Focused Beam Reflectance Measurement (FBRM) device. The direct measurement of other process variables, such as electric and electromagnetic field distribution, including, for example, microwave and UV light, is often not feasible in the constrained space of the respective processing equipment. However, the process outcomes, such as microbial inactivation,
18
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
nutrient degradation, structural changes, and material separation, are the true process indicators. Unless they are spatially resolved, these only give overall outcomes and are of no or limited value to validate local variations in a treatment cell or zone. An indirect measurement involves the evaluation of enzymatic, microbial, color, chemical, or any other biological or physical change that represents a change in temperature or any other process variable when typical measurement devices cannot be utilized. For example, temperature distribution changes after microwave sterilization can be measured using whey protein and measuring Maillard reaction components at different locations (Chapter 6). Another example is the use of magnetic resonance imaging (MRI) to measure the change in proton resonance frequency, referred to as chemical shift, to establish 3D temperature distribution changes (Chapter 7). Methods for validation will be covered in more detail in the following chapters. Once the data of the measured process variables or process outcomes are gathered, there are different ways of comparing simulated with measured data. A common method to validate transient simulations is the comparison of profiles at specific points of the modeling domain, which are measurable. Another approach is to compare model and measured data at several specific time and location coordinates (in a 2D or 3D grid) throughout the process period in a parity plot, for example, represent measured temperature versus simulated ones at identical locations and selected times in a plot (e.g., Knoerzer et al. 2007, 2008). Comparison of 2D or 3D distributions requires working in matrices. Distributions of inactivation or chemical or physical changes cannot be validated through direct measurements at selected points. The study of a certain volume in packages containing an initial amount of substance can partially resolve this problem. By this method overall averages for the whole vessel or vessel areas where packages are located are calculated from the predictions in the model. For example, Chapter 5 shows a case where a relative activity ratio (Eq. 5.16) is utilized to determine enzyme inactivation distributions after HPP.
1.5. Concluding Remarks After examining the literature, we note that only some of the Multiphysics models developed to describe innovative processing technologies have been thoroughly validated. The overarching aim of the models is to represent a process outcome that will provide certain design or optimization aids. However, in practice, not all of the validation variables or outcomes in Table 1.1 have been measured to match a certain model. In the case of HPP, PEF, ultrasound, and ohmic heating, more outcome-related models need adequate validation to establish, for example, accurate predictions of microbial, enzymatic or chemical reaction distributions, or other outcomerelated parameters. On the other hand, more complete outcome-related validated models have been developed for microwave processing. For example, the Multiphysics models presented in Chapter 6 have assisted in the filing of microwave sterilization processing in the U.S. Food and Drug Administration. As such, Multiphysics models will mainly be useful when reaching a stage of predicting process outcomes that leverage technologies to industrial levels. In order to achieve this, a more direct collaboration between processing equipment manufacturers, interested industry partners, and researchers is needed for successful design and implementation of innovative food processing technologies.
References Abbasi S, Azari S. 2009. Novel microwave-freeze drying of onion slices. Int J Food Sci Technol 44(5):974–979. Abdul Ghani AG, Farid MM. 2007. Numerical modeling of heat transfer in high pressure processing using computational fluid dynamics. Proceedings of the 4th International Conference on High Pressure Bioscience and Biotechnology, 1, 205–212. Ashokkumar M, Sunartio D, Kentish S, Mawson R, Simons L, Vilkhu K, Versteeg C. 2008. Modification of food ingredients by ultrasound to improve functionality: A preliminary study on a model system. Innov Food Sci Emerg Technol 9(2):155–160. Barbosa-Cánovas GV, Gongora-Nieto MM, Pothakamury UR, Swanson BG. 1999. Preservation of Foods with Pulsed Electric Fields. San Diego, CA, USA: Academic Presss. Bintsis T, Litopoulou-Tzanetaki E, Robinson RK. 2000. Existing and potential applications of ultraviolet light in the food industry—A critical review. J Sci Food Agric 80(6):637–645.
Chapter 1
Introduction to Innovative Food Processing Technologies
Bolton JR. 1999. Ultraviolet Applications Handbook. Ayr, ON, CAN: Bolton Photosciences, Inc. Buckow R, Schroeder S, Berres P, Baumann P, Knoerzer K. 2010a. Simulation and Evaluation of Pilot-Scale Pulsed Electric Field (PEF) Processing. J Food Eng 101(1):67–77. Buckow R, Truong BQ, Versteeg C. 2010b. Bovine cathepsin D activity under high pressure. Food Chem 120(2):474–481. Buffler CR. 1993. Microwave Cooking and Processing: Engineering Fundamentals for the Food Scientist. New York: AVI Book. Bull M, Olivier S, Diepenbeek R, Kormelink F, Chapman B. 2009. Synergistic inactivation of spores of proteolytic Clostridium botulinum strains by high pressure and heat is strain and product dependent. Appl Environ Microbiol 75(2): 434–445. Cameron M, McMaster LD, Britz TJ. 2009. Impact of ultrasound on dairy spoilage microbes and milk components. Dairy Sci Technol 89(1):83–98. Castro AJ, Barbosa-Cánovas GV, Swanson BG. 1993. Microbial inactivation of foods by pulsed electric-fields. J Food Process Preserv 17(1):47–73. Chen H, Tang J, Liu F. 2008. Simulation model for moving food packages in microwave heating processes using conformal FDTD method. J Food Eng 88(3):294–305. Chouliara E, Georgogianni KG, Kanellopoulou N, Kontominas MG. 2010. Effect of ultrasonication on microbiological, chemical and sensory properties of raw, thermized and pasteurized milk. Int Dairy J 20(5):307–313. COMSOL Multiphysics. 2007. Acoustics Module—User ’s Guide. Stockholm, Sweden: COMSOL AB. Contreras C, Martin-Esparza ME, Chiralt A, Martinez-Navarrete N. 2008. Influence of microwave application on convective drying: Effects on drying kinetics, and optical and mechanical properties of apple and strawberry. J Food Eng 88(1):55–64. Corrales M, Toepfl S, Butz P, Knorr D, Tauscher B. 2008. Extraction of anthocyanins from grape by-products assisted by ultrasonics, high hydrostatic pressure or pulsed electric fields: A comparison. Innov Food Sci Emerg Technol 9(1): 85–91. Datta AK, Hu W. 1992. Optimization of quality in microwaveheating. Food Technol 46(12):53–56. Decareau RV. 1985. Microwaves in the Food Processing Industry. Orlando: Academic Press Inc. Demirdoven A, Baysal T. 2009. The use of ultrasound and combined technologies in food preservation. Food RevInt 25(1): 1–11. Denys S, Van Loey AM, Hendrickx ME. 2000. A modeling approach for evaluating process uniformity during batch high hydrostatic pressure processing: Combination of a numerical heat transfer model and enzyme inactivation kinetics. Innov Food Sci Emerg Technol 1(1):5–19. Doblhoffdier O, Gaida T, Katinger H, Burger W, Groschl M, Benes E. 1994. A novel ultrasonic resonance field device for the retention of animal-cells. Biotechnol Prog 10(4):428–432.
19
Fakhouri MO, Ramaswamy HS. 1993. Temperature uniformity of microwave heated foods as influenced by product type and composition. Food Res Intern 26(2):89–95. Feng H, Yang W. 2005. Power ultrasound. In: YH Hui, ed., Handbook of Food Science, Technology, and Engineering, 121-1–121-9, New York: CRC Press. Fleischman GJ. 1996. Predicting temperature range in food slabs undergoing long term low power microwave heating. J Food Eng 27(4):337–351. Fujikawa H, Ushioda H, Kudo Y. 1992. Kinetics of escherichiacoli destruction by microwave irradiation. Appl Environ Microbiol 58(3):920–924. Garcia-Perez JV, Carcel JA, Riera E, Mulet A. 2009. Influence of the applied acoustic energy on the drying of carrots and lemon peel. Drying Technol 27(2):281–287. Geedipalli SSR, Rakesh V, Datta AK. 2007. Modeling the heating uniformity contributed by a rotating turntable in microwave ovens. J Food Eng 82(3):359–368. Gerlach D, Alleborn N, Baars A, Delgado A, Moritz J, Knorr D. 2008. Numerical simulations of pulsed electric fields for food preservation: A review. Innov Food Sci Emerg Technol 9(4):408–417. Goldblit SA, Wang DIC. 1967. Effect of microwaves on escherichia coli and bacillus subtilis. Appl Microbiol 15(6):1371. Gomez-Estaca J, Lopez-Caballero ME, Gomez-Guillen MC, de Lacey AL, Montero P. 2009. High pressure technology as a tool to obtain high quality carpaccio and carpaccio-like products from fish. Innov Food Sci Emerg Technol 10(2): 148–154. Grauwet T, Van der Plancken I, Vervoort L, Hendrickx ME, Van Loey A. 2010a. Mapping temperature uniformity in industrial scale HP equipment using enzymatic pressure-temperaturetime indicators. J Food Eng 98(1):93–102. Grauwet T, Van der Plancken I, Vervoort L, Hendrickx ME, Van Loey A. 2010b. Protein-based indicator system for detection of temperature differences in high pressure high temperature processing. Food Res Intern 43(3):862–871. Groschl M. 1998. Ultrasonic separation of suspended particles— Part I: Fundamentals. Acustica 84(3):432–447. Guerrero-Beltran JA, Barbosa-Cánovas GV. 2004. Review: Advantages and limitations on processing foods by UV light. Food Sci Technol Int 10(3):137–147. Gunasekaran S, Ay C. 1994. Evaluating milk coagulation with ultrasonics. Food Technol 48(12):74–78. Hamilton WA, Sale AJH. 1967. Effects of high electric fields on microorganisms .2. mechanism of action of lethal effect. Biochim Biophys Acta 148(3):789. Hawkes JJ, Limaye MS, Coakley WT. 1997. Filtration of bacteria and yeast by ultrasound-enhanced sedimentation. J Appl Microbiol 82(1):39–47. Heddleson RA, Doores S. 1994. Factors affecting microwaveheating of foods and microwave-induced destruction of foodborne pathogens—A review. J Food Prot 57(11):1025– 1037.
20
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Heddleson RA, Doores S, Anantheswaran RC. 1994. Parameters affecting destruction of salmonella spp by microwave-heating. J Food Sci 59(2):447–451. Hendrickx M, Knorr D. 2001. Ultra High Pressure Treatments of Foods. New York: Kluwer Academic / Plenum Publishers. Food engineering series. Hernando Saiz A, Tarrago Mingo S, Purroy Balda F, Tonello Samson C. 2008. Advances in design for successful commercial high pressure food processing. Food Aust 60(4):154–156. Hofman J, Shao L, Wols B, Uijtewaal W, Ijpelaar G, Beerendonk E, van Dijk H. 2007. Design of UV reactors by CFD: Model development and experimental validation. Proceedings of the COMSOL User Conference 2007, Grenoble, France. Hoover DG. 1997. Minimally processed fruits and vegetables: Reducing microbial load by nonthermal physical treatments. Food Technol 51(6):66. Hughes D, Nyborg W. 1962. Cell disruption by ultrasound. Streaming and other activity around sonically induced bubbles is a cause of damage to living cells. Science 138:108–114. Jambrak AR, Lelas V, Mason TJ, Kresic G, Badanjak M. 2009. Physical properties of ultrasound treated soy proteins. J Food Eng 93(4):386–393. Jung S, de Lamballerie-Anton M, Ghoul M. 2000a. Modifications of ultrastructure and myofibrillar proteins of post-rigor beef treated by high pressure. LWT Food Sci Technol 33(4):313–319. Jung S, Ghoul M, de Lamballerie-Anton M. 2000b. Changes in lysosomal enzyme activities and shear values of high pressure treated meat during ageing. Meat Sci 56(3):239–246. Klima J, Frias-Ferrer A, Gonzalez-Garcia J, Ludvik J, Saez V, Iniesta J. 2007. Optimisation of 20 kHz sonoreactor geometry on the basis of numerical simulation of local ultrasonic intensity and qualitative comparison with experimental results. Ultrason Sonochem 14(1):19–28. Knoerzer K, Juliano P, Gladman S, Versteeg C, Fryer P. 2007. A computational model for temperature and sterility distributions in a pilot-scale high-pressure high-temperature process. AIChE J 53(11):2996–3010. Knoerzer K, Regier M, Schubert H. 2008. A computational model for calculating temperature distributions in microwave food applications. Innov Food Sci Emerg Technol 9(3):374–384. Koutchma T. 2009. Advances in ultraviolet light technology for non-thermal processing of liquid foods. Food Bioprocess Technol 2(2):138–155. Kowalski S, Mierzwa D. 2009. Convective drying in combination with microwave and IR drying for biological materials. Drying Technol 27(12):1292–1301. Kowalski SJ, Rajewska K. 2009. Effectiveness of hybrid drying. Chem Eng Process 48(8):1302–1309. Kozempel MF, Annous BA, Cook RD, Scullen OJ, Whiting RC. 1998. Inactivation of microorganisms with microwaves at reduced temperatures. J Food Prot 61(5):582–585. Kulshrestha SA, Sastry SK. 2006. Low-frequency dielectric changes in cellular food material from ohmic heating: Effect of end point temperature. Innov Food Sci Emerg Technol 7(4):257–262.
Lebovka NI, Praporscic I, Ghnimi S, Vorobiev E. 2005. Does electroporation occur during the ohmic heating of food? J Food Sci 70(5):E308–E311. Lee H, Zhou B, Feng H, Martin SE. 2009. Effect of pH on Inactivation of Escherichia coli K12 by Sonication, Manosonication, Thermosonication, and Manothermosonication. J Food Sci 74(4):E191–E198. Loginova KV, Shynkaryk MV, Lebovka NI, Vorobiev E. 2010. Acceleration of soluble matter extraction from chicory with pulsed electric fields. J Food Eng 96(3):374–379. Lopez N, Puertolas E, Condon S, Raso J, Alvarez I. 2009a. Enhancement of the extraction of betanine from red beetroot by pulsed electric fields. J Food Eng 90(1):60–66. Lopez N, Puertolas E, Condon S, Raso J, Alvarez I. 2009b. Enhancement of the solid-liquid extraction of sucrose from sugar beet (Beta vulgaris) by pulsed electric fields. LWT Food Sci Technol 42(10):1674–1680. Martín-Belloso O, Soliva-Fortuny R. 2010. Pulsed electric fields processing basics. In: H Zhang, GV Barbosa-Cánovas, VM Balasubramaniam, P Dunne, D Farkas, J Yuan, eds., Nonthermal Processing Technologies of Food, Ames, IA: Wiley-Blackwell, 157–175. Metaxas AC. 1996. Foundations of Electroheat. Chicester: J. Wiley & Sons. Metaxas AC, Meredith RJ. 1983. Industrial Microwave Heating. London: Peter Peregrinus Ltd. Mudgett RE. 1985. Dielectric Properties of Foods, Microwaves in the Food Processing Industry, 15–56. Orlando: Academic Press Inc. Mudgett RE. 1986. Microwave properties and heating characteristics of foods. Food Technol 40:84–93. Nelson SO, Datta AK. 2001. Dielectric properties of food materials and electric field interactions. In: AK Datta, RC Anantheswaran, eds., Handbook of Microwave Technology for Food Application, 69–114. New York: Marcel Dekker Inc. Nicolaï BM, Scheerlinck N, Verboven P, Baerdemaeker JD. 2001. Stochastic finite-element analysis of thermal food processes. In: J Irudayarai, ed., Food Processing Operations Modeling. Design and Analysis, 265–304. New York: Marcel Dekker. Ohmori T, Shigehisa T, Taji S, Hayashi R. 1991. Effect of highpressure on the protease activities in meat. Agric Biol Chem 55(2):357–361. Ohshima T, Ushio H, Koizumi C. 1993. High-pressure processing of fish and fish products. Trends Food Sci Technol 4(11):370–375. Patist A, Bates D. 2008. Ultrasonic innovations in the food industry: From the laboratory to commercial production. Innov Food Sci Emerg Technol 9(2):147–154. Pehl M, Delgado A. 1999. An in situ technique to visualize temperature and velocity fields in liquid biotechnical substances at high pressure. Adv High Press Biosc Biotechnol 519–522. Pehl M, Werner F, Delgado A. 2000. First visualization of temperature fields in liquids at high pressure using thermochromic liquid crystals. Experiments Fluids 29(3):302–304.
Chapter 1
Introduction to Innovative Food Processing Technologies
Puertolas E, Lopez N, Saldana G, Alvarez I, Raso J. 2010. Evaluation of phenolic extraction during fermentation of red grapes treated by a continuous pulsed electric fields process at pilot-plant scale. J Food Eng 98(1):120–125. QWED Sp.z o.o. 2003. QuickWave-3D, Manual for the software, Warszawa. Rosen CG. 1972. Effects of microwaves on food and related materials. Food Technol 26(7):36. Roussy G, Pearce JA. 1995. Foundations and Industrial Applications of Microwaves and Radio Frequency Fields. Chichester: J. Wiley & Sons. Sastry SK, Datta AK, Worobo RW. 2000. Ultraviolet light. J Food Sci Suppl 65(12):90–92. Schubert H, Regier M. 2005. The Microwave Processing of Foods. Cambridge, England: Woodhead Publishing Limited. Seyderhelm I, Boguslawski S, Michaelis G, Knorr D. 1996. Pressure induced inactivation of selected food enzymes. J Food Sci 61(2):308–310. Seyhun N, Ramaswamy H, Sumnu G, Sahin S, Ahmed J. 2009. Comparison and modeling of microwave tempering and infrared assisted microwave tempering of frozen potato puree. J Food Eng 92(3):339–344. Sun D-W. 2007. Computational Fluid Dynamics in Food Processing. Boca Raton, FL: Taylor & Francis. Sun E, Datta A, Lobo S. 1995. Composition based prediction of dielectric properties of foods. J Microw Power Electromagn Energy 30(4):205–212. Sutkar VS, Gogate PR. 2010. Mapping of cavitational activity in high frequency sonochemical reactor. Chem Eng J 158(2): 296–304. Tang ZW, Mikhaylenko G, Liu F, Mah JH, Pandit R, Younce F, Tang JM. 2008. Microwave sterilization of sliced beef in gravy in 7-oz trays. J Food Eng 89(4):375–383. Terefe NS, Gamage M, Vilkhu K, Simons L, Mawson R, Versteeg C. 2009. The kinetics of inactivation of pectin methylesterase
21
and polygalacturonase in tomato juice by thermosonication. Food Chem 117(1):20–27. Toepfl S, Mathys A, Heinz V, Knorr D. 2006. Review: Potential of high hydrostatic pressure and pulsed electric fields for energy efficient and environmentally friendly food processing. Food Rev Int 22(4):405–423. Tolvanen R, Lunden J, Horman A, Korkeala H. 2009. Pilot-Scale Continuous Ultrasonic Cleaning Equipment Reduces Listeria monocytogenes Levels on Conveyor Belts. J Food Prot 72(2):408–411. Tonello C. 2010. Commercial high pressure plants around the world; personal communication (13/04/2010). NC Hyperbaric, Spain Turabi E, Sumnu G, Sahin S. 2008. Optimization of baking of rice cakes in infrared-microwave combination oven by response surface methodology. Food Bioprocess Technol 1(1):64–73. Uysal N, Sumnu G, Sahin S. 2009. Optimization of microwaveinfrared roasting of hazelnut. J Food Eng 90(2):255–261. Vilkhu K, Mawson R, Simons L, Bates D. 2008. Applications and opportunities for ultrasound assisted extraction in the food industry—A review. Innov Food Sci Emerg Technol 9(2): 161–169. Wilson DR, Dabrowski L, Stringer S, Moezelaar R, Brocklehurst TF. 2008. High pressure in combination with elevated temperature as a method for the sterilisation of food. Trends Food Sci Technol 19(6):289–299. Yen GC, Lin HT. 1996. Comparison of high pressure treatment and thermal pasteurization effects on the quality and shelf life of guava puree. Int J Food Sci Technol 31(2):205–213. Zhang H, Datta AK, Taub IA, Doona C. 2001. Electromagnetics, heat transfer, and thermokinetics in microwave sterilization. AIChE J 47(9):1957–1968.
Chapter 2 The Need for Thermophysical Properties in Simulating Emerging Food Processing Technologies Pablo Juliano, Francisco Javier Trujillo, Gustavo V. Barbosa-Cánovas, and Kai Knoerzer
2.1. Introduction Multiphysics modeling of any engineering problem comprises simultaneously solving partial differential equations (PDEs) of mathematical expressions representing different types of physical phenomena, that is, in a coupled form (Chen 2006). To solve the corresponding PDE, it is essential that the underlying equations, thermophysical properties, and boundary conditions are individually set up for each physical phenomenon. As such, the correct expression of the thermophysical properties as functions of the process variables affecting them is important for accurate model prediction (Knoerzer et al. 2007, 2008, 2010a; Juliano et al. 2009). In turn, accurate model prediction is challenged by the lack and the uncertainty (variability) of thermophysical property values for many materials, including foods and expressions of the specific process variables, such as temperature, pressure, and concentration (Knoerzer et al. 2010a). This chapter is an overview of the thermophysical properties required for Multiphysics modeling, and the dependence of these properties on technology-specific variables for accurate prediction of physical phenomena manifested during novel processing of foods.
Working with thermophysical properties in Multiphysics modeling of innovative food processing can result in a number of challenges, mainly: (1) understanding the nature of the food materials, (2) accurately determining the properties of the food materials under specific process conditions, and (3) understanding the functional dependence of a food material on the process variables (e.g., temperature, pressure, electric field strength, and (ultra)sound intensity). Food materials not only have varied composition and structure, but can also change due to processing conditions and during storage (e.g., biochemical reactions in fresh and living products, chemical changes provoked by process variables, changes in moisture content, micro- and macrostructural changes, and rheological changes). Thus, the overarching challenge is to identify expressions for each food material, including the composition variables (e.g., moisture, ash content, lipids, carbohydrates, and protein), structural variables (e.g., porosity and tortuosity), and processing variables (e.g., temperature and pressure). This chapter will show specifically that thermophysical properties do not vary significantly with process variables other than temperature and pressure. Seasonal variations in living food materials such as fruits, vegetables,
Innovative Food Processing Technologies: Advances in Multiphysics Simulation, First Edition. Edited by Kai Knoerzer, Pablo Juliano, Peter Roupas, and Cornelis Versteeg. © 2011 by John Wiley & Sons, Ltd. and Institute of Food Technologists. Published by John Wiley & Sons, Ltd. ISBN: 978-0-813-81754-5
23
24
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
and meats can hardly be predicted. Therefore, the variability of food materials may be unpredictable and difficult to include in a single model, which might affect the end result of a Multiphysics model or its predictability for different materials. However, as long as the composition of the food is included in the expression of thermophysical properties, and models are properly validated, these variations may be negligible.
2.2. Definitions and Methods to Determine Thermophysical Properties This section will define the thermophysical properties required to establish Multiphysics models for innovative food processes. In particular, suitable properties will be selected for processes requiring the use of temperature, elevated pressure, electric fields, ultrasound irradiation, microwave processing and ultraviolet light, and the eventual inclusion of material and process variables. When food components or other materials are included in the model, empirical expressions that have been adjusted to measured data may include other material variables (e.g., composition and porosity) as they intervene in
the mass, momentum, and energy balance processes. Fundamental governing equations included in CFD models comprise the following properties: density (mass, momentum, and energy conservation equation), specific heat capacity and thermal conductivity (energy conservation equation), and viscosity (momentum conservation equation). As shown in Table 2.1, equations for other (multi)physics phenomena to be coupled with CFD models require further thermophysical properties such as the compression heating properties (relevant in high-pressure processing), dielectric properties (radio frequency and microwave processing), electrical conductivity (ohmic heating and pulsed electric fields), sound absorption coefficient and velocity of sound (ultrasound processing), and absorptivity (ultraviolet processing).
2.2.1. Density, Porosity, and Related Properties The density, ρ, of a material is defined as mass per unit volume (SI unit of density is kg/m3). Indeed, there are different forms of density that can be used, such as true, material, particle, apparent, and bulk
Table 2.1. Summary of essential properties for emerging food processing technologies. Technology
Property
Equation
All food processing technologies
Density Specific heat capacity Thermal conductivity Viscosity Thermal expansion coefficient Compressibility Compression heating coefficient Dielectric constant Loss factor Electrical conductivity Electrical conductivity
Mass, momentum, Energy conservation equation Momentum conservation equation
High-pressure processing (HPP) and High-pressure thermal sterilization (HPTS) Microwave and radio frequency Ohmic heating and pulsed electric fields Ultrasound
Ultraviolet
Sound absorption coefficient Velocity of sound Absorptivity Absorption coefficient (or spectral absorption coefficient) Optical density
Compression heating (Eq. 2.10; Chapters 4 and 5) Maxwell’s equations including the constitutive relations (Chapters 6 and 7) and energy conservation including source term Charge conservation and energy conservation including source term (Chapters 8, 9, 11) Wave equation, Helmholtz equation, momentum, and energy conservation including source terms (Chapter 12) Radiation intensity (Chapter 14)
Chapter 2
Thermophysical Properties in Simulating Food Processing Technologies
density, depending on its application in process calculations or product characterization. However, the apparent density is more commonly used as input into the model equations. The volume measurement method is what determines the difference between them. True and material densities are calculated by excluding volumes occupied by internal and external pores within the food, while particle, apparent, and bulk densities are determined from less accurate measurement methods that include pore volume (Barbosa-Cánovas et al. 2005). In most engineering designs, solids and liquids are assumed to be incompressible—in other words, density changes moderately with changes in temperature and pressure. In food engineering, however, the density of solid and liquid foods changes with temperature and pressure, and composition changes as well. In the case of liquid foods, no generic equations exist to predict the density. In the literature most of the density data are correlated empirically as a function of temperature, pressure, water, solids, and fat content. Different types of nonlinear correlation such as exponential, quadratic, and cubic are used to relate density and moisture content (Lozano 2007). Another way of accounting for a material’s structure is in its porosity, which indicates the volume fraction of void space or air space inside the material. Volume determination is relative to the amount of internal (or closed) or external (or open) pores present in the food structure. Therefore, like density, different forms of porosity are also used in food processing studies, namely open pore, closed pore, apparent, bulk, and total porosities (Rahman 1995; Barbosa-Cánovas et al. 2005, 2007). Porosity in foods is mainly predicted from empirical correlations, which are valid for individual foods under given processing conditions. Fundamental models exist that are based on the conservation of mass and volume, as well as a number of other terms that account for interaction of components and formation or collapse of air or the void phase during processing (Lozano 2007). Shrinkage or the reduction in volume or geometric dimensions during processing is also important in solid materials. During post-processing the volume of the material is larger than its initial
25
volume, and is termed “expansion.” Two types of shrinkage, isotropic and anisotropic, are usually observed in the case of food materials. Isotropic shrinkage is described as the uniform shrinkage of materials under all geometric dimensions, whereas anisotropic (or nonuniform) shrinkage develops in different geometric dimensions. The former is common in fruits and vegetables, while the latter is known in animal tissue, as in meat and fish (Sahin and Sumnu 2006). Most of the density, shrinkage, and porosity prediction models for liquid and solid foods are empirical in nature. Recent models have been developed to predict porosity during air drying based on drying temperature, moisture content, initial porosity, and product type (Lozano 2007). Volume change and porosity are important parameters in estimating diffusion coefficients for shrinking systems. Furthermore, porosity and tortuosity are used to calculate effective diffusion during the mass transfer process (Knoerzer et al. 2004). A material’s volume can be measured by buoyant force, liquid, gas or solid displacement, gas adsorption, or by estimating the material’s geometric dimensions. The buoyant force method for apparent or particle volume determination utilizes sample weight differences in air and water, while the liquid displacement method measures the increase in liquid volume (material is immersed in a non-wetting fluid such as mercury or toluene). A gas pycnometer is a gas displacement device that uses air pressure differences in a sample cell connected to a manometer to determine material volume. Apparent or particle density can be determined by coating particles in order to include internal pores in the volume measured. For solid displacement, sand or glass beads can be used instead. Porosity can be measured by direct and microscopic methods, or can be estimated from density data.
2.2.2. Viscosity The viscosity ( μ ) is a physical property of fluid materials (gases, liquids, or semisolid foods) and represents the internal friction of a fluid or its resistance to flow (the SI unit of dynamic viscosity is Pa·s) (Bourne 2002). Similar to the friction that occurs between moving solids, viscosity transforms the
26
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
kinetic energy of motion of the fluid into heat. For instance, highly viscous food materials like honey offer higher resistance to flow than lower viscosity liquids such as water. Thus, more power is consumed by the pump during pumping of honey to achieve the same flow rate of pumping water. In addition, honey exhibits a higher temperature increase under flowing conditions than water due to higher viscous heat dissipation (caused by friction). Modeling food-processing operations often involves solving the momentum transport equation, which accounts for the balance between the forces (e.g., pressure gradients and stress tensor) applied to a differential volumetric element of a fluid, and the resulting acceleration of the fluid. Viscosity is usually incorporated into the rheological model as representing the stress tensor, which accounts for the shear stress acting upon the fluid. Shear stress (τ ) is a force per unit of area acting parallel or tangential to the fluid element:
τ=
F A
(2.1)
Simple liquids and gases such as water and air are called Newtonian fluids, given that they exhibit an ideal correlation between the shear stress (force per unit area acting tangential to the fluid) and the resulting velocity gradient perpendicular to the direction of shear:
τ=μ
dv dy
(2.2)
For a Newtonian fluid, viscosity represents a linear correlation between shear stress and velocity gradient. However, foods are structurally complex materials that frequently exhibit non-Newtonian behavior (Tabilo-Munizaga and Barbosa-Cánovas, 2005; Welti-Chanes et al. 2005). Non-Newtonian fluids are usually divided into the following general classes: (1) those with properties independent of shear rate and (2) those with properties dependent on shear rate (Steffe 1992). Some common rheological models of liquid foods are Power law model
τ = K (γ )
n
(2.3)
Bingham model
τ = τ o + η pγ
(2.4)
Herschel-Bulkley model
τ = τ o + K (γ )
n
(2.5)
where γ = dv dy is the shear rate and η p is apparent viscosity. For a pure substance, the viscosity is highly dependent on temperature and to a lesser extent on pressure. For complex materials like food, the viscosity also depends on composition. Viscosity is usually determined by measuring the resistance to flow in a capillary tube, or the torque produced by the movement of an element through the fluid. There are two main categories of viscometers applicable to foodstuffs: capillary, and falling ball, as well as commercial rheometers able to provide viscosity according to rheological models. For Newtonian liquid foods it is sufficient to measure μ at a single value of γ . In order to describe a non-Newtonian food, additional properties must be measured by attaining flow curves with a rheometer and determining yield stress. Viscoelastic and semisolid foods have been extensively studied during the last decades. Rheological characterizations of nonNewtonian foods have been in the form of τ versus γ curves, dynamic characteristics, time effect on viscosity at constant temperature, and others. Values of these parameters have been compiled by different authors (Kokini 1992; Steffe 1992; Rao 2007). Liquid foods, such as beer, tea, coffee, clarified fruit juice, wines, cola drinks, vegetable oils, and milk exhibit Newtonian behavior. As an approximation, viscosity of Newtonian foods can be estimated as the weighted average between the viscosity of water ( μ w ) and that of the prevalent soluble substance. Different empirical equations relating liquid food viscosity with both soluble solids and temperature have been published (Rao 2007). The viscosity of salt and sugar solutions (two major food solutes) are also available (Kubota et al. 1981). Vitali and Rao (1984) reported that the effect of concentration on viscosity of fruit juices at constant temperature can be represented by an exponential-type relationship. Hydrolytic enzymes present in natural fruit and
Chapter 2
Thermophysical Properties in Simulating Food Processing Technologies
vegetable juices, or purees, degrade polysaccharide chains and therefore alter the viscosity.
2.2.3. Specific Heat Capacity The specific (isobaric) heat capacity, Cp, is the amount of heat (in joules) needed to raise the temperature of 1 kg of matter by 1 K at a given temperature. The SI unit for Cp is therefore J/kg/K. Specific heat capacity of solids and liquids depends on temperature but does not generally exhibit pronounced pressure dependence. It is common to use the constant pressure specific heat, Cp, which thermodynamically represents the change in enthalpy H (kJ/kg) for a given change in temperature T when it occurs at pressure P: ⎛ ∂H ⎞ CP = ⎜ ⎝ ∂T ⎟⎠ P
(2.6)
Assuming there is no phase change, the amount of heat Q that must be added to a unit mass M (kg of mass or specific weight kg/m3) to raise the temperature from T1 to T2 can be calculated using the following equation: Q = M ⋅ CP ⋅ (T2 − T1 )
(2.7)
The specific heat of foods is drastically influenced by water content. For example, specific heat has been found to vary exponentially with water content in fruit pulps above ambient temperatures. Furthermore, nonaqueous components show lower Cp (Barbosa-Cánovas et al. 2007; Lozano 2007). The specific heat of oils and fats is usually about one-half the specific heat of water, while the specific heat of dry materials in grains and powders is approximately one-third to one-fourth that of water (Rahman 1995). As a result of solute–water interactions, the Cp of each individual component in a food differs from the Cp of a pure component, and usually changes with the concentration of soluble solids. Cp has been measured at different temperatures in fresh and dried fruits, meats, cereal grains and cereal products, oils and fats, powders, and other dry foods (Lozano 2007). Although linear correlations of Cp with concentration are known in liquid foods, variations are often neglected for engineering calculations at near room temperature.
27
Several methods are known for measuring specific heat capacity experimentally. Cp can be determined by methods of mixtures and differential scanning calorimetry (DSC). For methods of mixtures, a calorimeter of known specific heat is used and CP is determined from a heat exchange balance. In the DSC method, the sample is put in a special cell where the temperature is increased at a constant heating rate. The specific heat of the food is obtained from a single heat thermogram, which records heat flow as a function of time or temperature.
2.2.4. Thermal Conductivity and Diffusivity Thermal conductivity, k, is the property of a material indicating its ability to conduct heat. It represents the quantity of heat Q that flows per unit time through a food of a certain thickness and area with a specific temperature difference between faces; the SI unit for k is W/m/K. The rate of heat flow Q through a material by conduction can be predicted by Fourier ’s law of heat conduction. A simplified approximation follows: k ⋅ A ⋅ (T2 − T1 ) Q = x
(2.8)
where A is the surface area of the food, x is its thickness, T1 is the temperature at the outer surface where heat is absorbed, and T2 is the temperature at the inner surface. Thermal diffusivity α (SI unit, m2/s) defines the rate at which heat diffuses by conduction through a food composite and is related to k and Cp through density ρ as follows:
α=
k ρ ⋅ CP
(2.9)
Thermal diffusivity establishes the speed of heat of three-dimensional propagation or diffusion through the material. It is represented by the rate at which temperature changes in a certain volume of food material, while transient heat is conducted through it in a certain direction in or out of the material (depending on whether the operation involves heating or cooling). Equation 2.9 shows that α is directly proportional to the thermal conductivity at a given
28
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
density and specific heat. Physically, it relates the ability of the material to conduct heat to its ability to store heat (Barbosa-Cánovas and Rodríguez 2005). The thermal conductivity of food materials is greatly influenced by the water content. Water shows greater relative magnitudes in comparison to other food constituents. Thus, k increases with increased moisture content. It is common to find a linear relationship between thermal conductivity and moisture content at ambient conditions, but also a quadratic relationship, as well as multiple correlations of moisture, temperature, and composition can be found for k in food materials (Lozano 2007). Some models consider that different components of foods (e.g., fibers) are arranged in layers either parallel or perpendicular to the heat flow (Salvadori et al. 1997). For example, in products such as meat, heat is usually transferred parallel to the fibers and k is dependent on the direction of the heat flow. More general in nature are the randomly distributed models, which consider that the food is composed of a continuous phase with a discontinuous phase dispersed within (solid particles being in either regular or irregular arrangement; Mattea et al. 1989; Lozano 2007). In porous materials, porosity must be included in the model because air has a thermal conductivity much lower than that of other food components. Models including density or porosity, and pressure, have been developed for fruits and vegetables, meat and meat products, dairy products, cereals, and starch (Lozano 2007). Several models for predicting α in foods have also appeared in the literature; however, most are product-specific and a function of water content (sometimes water activity) or temperature. Although the influence of carbohydrates, proteins, fat, and ash on thermal diffusivity has also been investigated, it was found that temperature and water content are the major factors affecting α (Rahman 1995). Experimental methods used to determine k are, for example, the Fitch method and the line source method. In the Fitch method, a solid slab of a certain food receives heat from one layer and conducts it to a copper plug. Conductivity k is obtained from the food’s temperature as a function of heat conduction time. The line source method is based on the
use of a thermal conductivity probe to measure a temperature–time relation on a thin cylindrical food piece to which constant heat is applied. Thermal diffusivity α is usually either found by direct experimental methods or estimated through Equation 2.9. Several direct methods for α determination can be based on a one-dimensional heat conduction equation where geometrical boundary conditions are defined. For instance, an apparatus can be used where the sample is located in a special cylinder and immersed in a water bath at constant temperature. Thermocouples located at the center of the sample (axis) and surface of cylinder measure temperature at different heating times. Transient temperature variations are used for the analytical solution. Indirect methods, although they might yield more accurate diffusivity values, require more time and instrumentation for the three-parameter determination (ρ, k, and CP; Lozano 2007). It is worth mentioning the role of the surface heat transfer coefficient, as it is one of the important parameters necessary for design and control of food processing and associated equipment where fluids (air, nitrogen, steam, water, or oil) participate. Although the surface heat transfer coefficient is not a property of food, it is used to quantify the transfer rate of heat by convection from a liquid or a gas (especially boiling liquids and condensing vapors) to the surface of foods. It plays an important role when evaluating the effectiveness of heat transfer in processes where hot water or steam is applied through the evaluation of the overall resistances during heat transfer (Juliano et al. 2008).
2.2.5. Compression Heating Coefficient and Related Properties All materials change their volume when subjected to temperature or pressure change. For food processing operations it is commonly assumed that pressure does not appreciably affect the volume of a liquid or the solid objects; however, in the case of food processing under high hydrostatic pressure up to several hundred MPa, this assumption does not hold true. A significant compression of fluids and some solids (especially polymeric materials used, e.g., as food
Chapter 2
Thermophysical Properties in Simulating Food Processing Technologies
packaging) occurs when materials are subjected to these pressure levels. The adiabatic temperature change of an isotropically compressed or a decompressed material can be expressed as follows: dT αP = ⋅ T = kC ⋅ T dP ρ ⋅ CP
(2.10)
where α P is the thermal expansion coefficient and kC is the compression heating coefficient. The coefficient of thermal expansion describes how the volume of an object changes with change in temperature. In particular, it measures the fractional change in volume per degree change in temperature at a constant pressure; the SI unit is K−1. Likewise, the compressibility is a measure of the relative volume change of a fluid or solid as a response to a pressure (or mean stress) change; the SI unit is Pa−1. As indicated earlier, all materials expand or contract when their temperature or pressure changes, and the expansion or contraction always occurs in all directions. This change in volume occurs at the same rate in any direction in isotropic materials. Some materials expand when cooled, such as freezing water, and therefore have negative thermal expansion coefficients (Knoerzer et al. 2010a). The adiabatic compressibility β S is a thermodynamic property and can be written at constant entropy as:
βS = −
1 ⎛ ∂V ⎞ V ⎜⎝ ∂p ⎟⎠ S
(2.11)
The thermal expansion coefficient α P is a thermodynamic property and can be written at a constant pressure as:
αP =
1 ⎛ ∂V ⎞ ⎜ ⎟ V ⎝ ∂T ⎠ P
(2.12)
where V is the volume of the material and ∂V/∂T is the rate of change of that volume with pressure and temperature, respectively. In general, the thermal expansion coefficients increase from solids over liquids to gases (Harvey et al. 1996). The variation of this parameter has been studied for water from the NIST database by Juliano et al. (2008). However, very limited information on
29
the thermal expansion coefficient of food materials is available in the literature. For example, values for sunflower and olive oils, as well as tomato paste and pressure-transmitting fluids, have been reported by Guignon et al. (2009, 2010) and Aparicio et al. (2010), respectively. Min et al. (2010) have determined the compressibility (and density) of selected liquid and solid foods as they vary with increasing pressure. As shown in Equation 2.10, all compressible materials undergo a change in temperature when subjected to pressure. The degree of temperature change is hereby dependent on a complex interaction of the thermal expansion coefficient, density, and specific heat capacity of the material. It is challenging to determine these properties separately under highpressure conditions. Therefore, for predicting the extent of compression heating during a high-pressure process the pressure–temperature-dependent properties can be combined into one pressure–temperaturedependent parameter, referred to as the compression heating coefficient kC (Knoerzer et al. 2010a, 2010b) with the SI unit Pa−1. For modeling high-pressure processes, knowledge of these properties is imperative for all materials involved in the modeled scenario (see Chapters 4 and 5 for further information). The variation of compression heating of water based on thermophysical properties from the NIST database for water and steam (Harvey et al. 1996) has been summarized in the literature (Ardia et al. 2004; Knoerzer et al. 2007; Mathys and Knorr 2009). Limited information is available on the compression heating for food materials. Studies on selected food materials have been published in the last few years (Otero et al. 2000, 2006; Rasanayagam et al. 2003; Ardia et al. 2004; Patazca et al. 2007; Shao et al. 2007; Zhu et al. 2007). Until recently, the extent of compression heating of nonfood solid materials in high-pressure processing was unknown and assumed negligible. This assumption holds true for metals, which not only have lower thermal expansion coefficients, but at the same time exhibit significantly higher densities, making the kC values small compared with those of liquids. However, it was shown by Knoerzer et al. (2010b) that some polymeric insulating plastics undergo pronounced heating under pressure, often
30
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
exceeding the adiabatic heating of water. This can be explained by the fact that these materials often have lower densities, but particularly lower specific heat capacities, and exhibit greater compressibility, associated with greater thermal expansion capacity. Also for liquids, pronounced differences in kC values can be found, as shown in Knoerzer et al. (2010a), associated with differences in molecular bonds, that is, hydrogen and van der Waal’s bonds affecting the thermal expansion coefficients. Water, for example, shows less pronounced heating than nonpolar liquids, such as propylene-glycol, with the difference being that the values are increasing for water with increasing pressures and temperatures; whereas nonpolar liquids show greatest compression heating at low pressures, and almost no temperature dependency (Knoerzer et al. 2010a, 2010b). The compression heating coefficient of food materials can be derived from the temperature– pressure profiles obtained in an adiabatic high-pressure system. There are certain types of thermocouples (i.e., K and T types), which can reliably measure temperature at high-pressure conditions. A detailed description of this method can be found elsewhere (Knoerzer et al. 2010a, 2010b). Thermodynamic equations are able to predict the thermal expansion coefficient and the compressibility of pure water and gases. However, food materials are more complex and their values cannot be derived theoretically. As long as density and heat capacity are known as functions of temperature and pressure, the thermal expansion coefficient can be calculated from the compression heating of the food material according to Equation 2.10. Very recently, a volume piezometer has been integrated into a high-pressure system to provide in situ data for compressibility and density (Min et al. 2010).
2.2.6. Dielectric Properties The dielectric permittivity, ε, is a complex number used to explain interactions of foods with electric fields. It determines the interaction of electromagnetic waves with matter and defines the charge density under an electric field. In solids, liquids, and gases the complex permittivity comprises two values:
• the real part, dielectric constant, ε', related to the capacitance of a substance and its ability to store electrical energy; and • the imaginary part, dielectric loss factor, ε", related to the attenuation of the electromagnetic energy, dissipated into thermal energy when the food is subjected to an alternating electrical field (i.e., dielectric relaxation and ionic conduction). Both parameters are dimensionless because they are relative values (Chapters 6 and 7). Dielectric properties (ε', ε") are primarily determined by the food’s chemical composition (presence of mobile ions and permanent dipole moments associated with water and other molecules) and, to a much lesser extent, by their physical structure (Barbosa-Cánovas et al. 2007). The influence of water and salt (or ash) content largely depends on the manner in which they are bound or restricted in movement by other food components. Free water and dissociated salts have high values of the dielectric properties, while bound water, associated salts, and colloidal solids exhibit lower values. Power dissipation is directly related to the dielectric loss factor ε" (see also Chapters 6 and 7) and temperature increase during microwave processing (as per the energy conservation equation) further depends on the specific heat of the food, the thermal conductivity, and the density of the material. Permittivity also strongly depends on the frequency of the applied alternating electric fields. Frequency contributes to the polarization of (polar) molecules such as water. In general, the permittivity increases with temperature, whereas the loss factor may either increase or decrease depending on the operating frequency (Mohsenin 1984; Regier and Schubert 2005). In microwave processing at frequencies of either 915 MHz or 2.45 GHz, the loss factor decreases with increasing temperature, caused by a greater mobility of ions and dipoles due to lower viscosities (Regier and Schubert 2005). Comprehensive tabulations of electrical property data are available for foods (Zhang 2007). The electrical field inside the food is determined by the dielectric properties and geometry of the load and the food processing chamber configuration.
Chapter 2
Thermophysical Properties in Simulating Food Processing Technologies
Dielectric properties are of great importance in measuring and heating applications, and also in the selection of proper packaging materials and in the design of microwave and radio frequency heating equipment since they influence how the material interacts with the electromagnetic waves. They furthermore determine the penetration depth of electromagnetic waves into foods. Known methods for measuring dielectric properties are the cavity perturbation, open-ended coaxial probe, and transmission line methods. Since modern microwave network analyzers have become available, the methods of obtaining dielectric properties over wide frequency ranges have become more efficient. Computer control of impedance and network analyzers has facilitated the automatic measurement of dielectric properties; special calibration methods have also been developed to eliminate errors caused by unknown reflections in the coaxial line systems. Distribution functions and empirical relationships can be used to express the temperature dependence of dielectric properties.
2.2.7. Electrical Conductivity The electrical conductivity, σ, is a measure of how well electric current flows through a material with a certain cross-sectional area A, length L, and resistance R. It is the inverse value of electrical resistivity (measure of resistance to electric flow), as expressed in the following equation (Regier and Schubert 2005; Zhang 2007):
σ=
L A⋅ R
(2.13)
The electrical conductivity (SI unit, S/m) of foods has been found to increase with temperature and also with water and ionic content. Mathematical relationships have been developed to predict the electrical conductivity of food materials (Buckow et al. 2010). Below freezing temperatures, electrical conductivity shows a pronounced decrease, since ice conducts less well than water. Phase transitions in foods (such as starch gelatinization) and cell structural changes also affect electrical conductivity. As
31
in thermal properties, the porosity of the food plays an important role in the conduction of electrons through the food. Electrical properties are important when processing foods with pulsed electric fields, ohmic heating, induction heating, radio frequency, and microwave heating (Chapters 6–11). Electrical conductivity plays a fundamental role in ohmic heating, a process in which electricity is transformed into thermal energy when an alternating current (AC) is applied to the food. Ohmic heating has potential use in fluid pasteurization; hence, knowing the effective electrical conductivity or the overall resistance of liquid–particle mixtures is important. Liquids and liquid–particle mixtures can also be pasteurized with pulsed electric fields technology. In this case, products with low electrical conductivity are better and more energy-efficient to process, unless a synergy of heat and electric field strength is assumed; then higher electric conductivities assist in heating up the liquid from moderate initial temperatures to the process target temperature. The electrical conductivity of a material is generally measured by passing a known current at constant voltage through a known volume of the material and by determining resistance. The total conductivity is then calculated simply by taking the inverse of the total resistivity. Basic measurements involve bridge networks (such as the Wheatstone bridge circuit) or a galvanometer. There are other devices that measure electrical conductivity of foods under ohmic or conventional heating conditions, using thermocouples and voltage and current transducers to measure voltage across and current through samples (Zhang 2007).
2.2.8. Acoustic Properties Modeling of sound fields is gaining importance in the food industry given several new applications of power ultrasound, such as enzyme activity modulation and enhanced extraction. The most important properties of a fluid, utilized to model sound fields, are speed of sound ( c ) and attenuation coefficient ( α ).
32
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
2.2.8.1. Speed of Sound The speed of sound is the rate at which an acoustic wave travels through a fluid. This thermodynamic property of the fluid depends on the following equilibrium conditions: ⎛ ∂p ⎞ c2 = ⎜ ⎟ ⎝ ∂ρ ⎠ adiabatic
(2.14)
For an ideal gas, Equation 2.14 takes the form: c 2 = γ RT
(2.15)
where γ = ( c p cv ) , R is the universal constant, and T is the absolute temperature (Lighthill 1978). For an ideal gas, c depends only on temperature. For liquids, the speed of sound can be expressed as: c2 =
1 βρ
(2.16)
where β is the adiabatic compressibility. β and ρ vary with the equilibrium temperature and pressure of the liquid. Hence, the speed of sound of pure liquids depends on temperature and pressure. Since there is no simple theory for predicting these variables, this dependence must be measured experimentally; the resulting values are usually expressed as empirical equations (Shoitov and Otpushchennikov 1968). As any other thermodynamic property, the speed of sound is a function of composition for mixtures. In nondispersive media, acoustic waves travel at the same speed of sound regardless of frequency (Leighton 1997). However, in a dispersive medium the speed of sound can vary with frequency (McClements and Povey 1989). This may occur in food emulsions where a secondary phase is dispersed in a continuous phase. In an ideal case, that is, a non-scattering two-phase system, the volume average values for compressibility and density can be used (McClements et al. 1990):
β = (1 − φ ) β1 + φβ2
(2.17)
ρ = (1 − φ ) ρ1 + φρ2
(2.18)
where φ is the dispersed phase volume fraction and the subscripts 1 and 2 represent the continuous and dispersed phases, respectively. Then, the mixture values of β and ρ can be used to calculate the speed
of sound. More realistic approaches include the effect of sound scattering, a deviation or reflection of sound at the phase boundary. The two most important sources of sound scattering, in the long wavelength limit (particle radius of dispersed phase r << λ wavelength of ultrasonic wave), are viscoinertial and thermal scattering (McClements et al. 1990). Visco-inertial scattering occurs due to differences of density between the phases, whereas thermal scattering is caused by differences in compressibility, heat capacity, and thermal diffusion between the phases. This will be explained further in Section 2.2.8.2. Ament (1953) developed an equation of sound propagation through emulsions, accounting for visco-inertial scattering. The Ament formula can be plotted in a three-dimensional figure to visualize the dependence of the speed of sound with the volume fraction and Γr . The latter is the product of the shear wave skin depth ( Γ ), at which the amplitude of the wave has diminished to 1/e of its original value, and particle radius of the dispersed phase (r). It has been shown that for the region where Γr ≈ 1 the speed of sound is frequency-dependent and in those regions where this condition does not apply ( Γr ≠ 1) the speed of sound is frequencyindependent (Povey and McClements 1998). The speed of sound in liquids can be strongly influenced by the presence of bubbles, especially for cavitating systems, where bubbles are generated by pressure changes during the propagation of highintensity ultrasonic waves in liquids. For example, the speed of sound in a cavitating liquid may decrease from 1,500 m/s (in the case of pure water) to 20 m/s, which is even less than the velocity of the speed of sound in air (340 m/s; Servant et al. 2001). Systems containing bubbles may exhibit resonant scattering, where attenuation is sharply increased near the resonant frequency. In resonant scattering the magnitude of the scattered wave is of the same order as the incident wave. Multiple scattering of the bubbles has a pronounced effect on the speed of sound. In this case, the speed of sound and the attenuation are a complex function of the frequency and number and size of bubbles (McClements and Povey 1989). The speed of sound is generally determined by measuring the acoustic transit time over a known
Chapter 2
Thermophysical Properties in Simulating Food Processing Technologies
path length. For instance, a receiver acoustic interferometer allows measuring the speed of sound by knowing the distance traveled by the sound and the phase shift between received and transmitted signals (Barthel and Nolle 1952; McCartney and Drouin 1977). The pulse-echo-overlap (PEO) method sends a pulsed sound from the transmitter to a reflector. The signal on its way back again excites the transducer and a new echo is sensed. The process is repeated until the wave is completely damped. The speed of sound is obtained by measuring the time between the maximum of two consecutive echoes (Junquera et al. 2002). Broadband resonance techniques have also been widely used to determine speed of sound and to characterize liquids (Eggers and Kaatze 1996). Unfortunately, in spite of current technologies capable of accurately determining the speed of sound in fluids, and the increased use of ultrasound to characterize food materials, there is a lack of reported data on speed of sound of food materials in the public domain. 2.2.8.2. Sound Attenuation Coefficient Sound attenuation is the loss occurring during the propagation of sound waves. The attenuation coefficient represents the damping of the initial pressure amplitude P0 of an ultrasonic wave propagating along a distance r (Lamberti et al. 2009): P = P0 e −α r
(2.19)
The sound attenuation at ultrasonic frequencies in a pure liquid is caused by absorption mechanisms that convert energy from the ultrasonic wave into heat (McClements et al. 1990). In liquid, the most important mechanisms are viscosity, thermal conduction, and molecular relaxation. As explained in Section 2.2.2, viscosity transforms the fluid kinetic energy of motion into heat. Hence, viscous losses occur when there is a relative motion between adjacent portions of the fluid upon passage of sound waves. Besides that, the temperature of the fluid locally increases during compression and decreases during expansion. Thermal conduction losses occur when heat flows from the compressed and “hot” parts of the medium to the adjacent and expanded “cold” parts. Molecular relaxation losses are caused by
33
molecular level processes, such as conversion of kinetic energy of molecules into stored potential energy formed by structural rearrangement of clusters, and rotational and vibrational energies of molecules (Kinsler et al. 2000). For multiphase systems such as emulsions, the energy of the ultrasound wave may be scattered at the interface between primary and secondary phases. When ultrasound is scattered, the ultrasound energy is redirected away from the incident wave (McClements and Povey 1989). A first ideal approach assumes that there is no interaction between the phases. Thus, the attenuation of a twophase non-scattering system is equal to the volume average of the absorption coefficients:
α = (1 − φ ) α1 + φα 2
(2.20)
However, in real emulsions, scattering of ultrasound has a pronounced effect on both speed of sound and attenuation (McClements et al. 1990). The difference between the overall attenuation ( α ) and that caused by absorption alone ( α o ) is termed “excess attenuation” ( α exc ), which is further defined as a combination of various scattering mechanisms (McClements and Povey 1989):
α = α o + α exc
(2.21)
Overall attenuation is usually described with the simplified equation below (Eggers and Kaatze 1996):
α ( f ) = Bf 2 + α exc ( f )
(2.22)
where f is frequency, Bf = α o is the attenuation due to absorption alone, and B is a constant. As mentioned before, the two main sources of scattering in the long wavelength limit ( r << λ ) are visco-inertial ( α vis ) and thermal scattering ( α th ). Visco-inertial scattering occurs when droplets have a different density compared with the surrounding fluid. In the presence of an ultrasonic wave a net force causes the droplet to oscillate; the oscillation is damped by the viscosity of the surrounding fluid. In thermal scattering, differences in compressibility, heat capacity, and thermal diffusion between the droplets of the dispersed phase and the continuous primary phase cause the ultrasound wave to be scattered (Povey and McClements 1998). When the compressibility of the 2
34
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
particles differs from the surrounding liquid, the particles and the liquid expand differently under the influence of the ultrasonic wave. This difference creates a temperature gradient at the particle–liquid interface. Energy flowing at this boundary is irreversible according to thermodynamic principle (Dukhin et al. 2005). The thermal scattering of a dispersion is a function of the thermal expansion, heat capacity, and thermal conductivity of both phases, and also depends on the size distribution of the particles. As explained in Section 2.2.8.1, systems containing bubbles may exhibit multiple strong scattering, which not only has a pronounced effect on the speed of sound, but also affects the overall attenuation of the sound wave. Therefore, sound fields can be strongly attenuated a few millimeters from the source in high-power horn reactors due to the presence of cavitation bubbles (see Chapter 12; Trujillo and Knoerzer 2009). Similar to the speed of sound, attenuation can also be experimentally determined via standard methods such as ultrasonic pulse techniques (McSkimin 1957). Chapter 12 also explains a method of determining the absorption coefficient (only absorption without scattering) based on measuring acoustic streaming. However, also for the absorption coefficients, there is a lack of experimental data reported in the public domain. Hence, attenuation measurements are needed for future modeling of ultrasoundbased processes. For cavitating systems, there are still many complexities that need to be solved, given the strong scattering produced by bubbles formed during cavitation.
absorber of electromagnetic radiation (c, mol/L), and path length of light (d, m).
ε=
A c⋅d
(2.23)
In spectroscopy, the absorbance A (optical density) is defined as: A = − log
I I0
(2.24)
where I is the intensity of light at a specified wavelength that has passed through a sample (transmitted light intensity) and I0 is the intensity of the light before it enters the sample (incident light intensity). The liquid itself and the concentration of the suspended units can be transparent if A << 1, opaque if A >> 2 or semitransparent for anything in between these extremes. In a majority of cases, liquid foods will absorb UV radiation. The absorptivity of a pure substance is determined by means of spectrophotometric analysis. In particular, since this property is utilized to model UV processing, the absorptivity is determined according to the operational frequency. Generally, a standard curve of the absorbance versus concentration of a pure substance is determined and the slope of the curve defines the absorptivity. Chemical handbooks such as the Merck Index (Merck Publishing Group, Rahway, NJ) also provide values of absorptivity for standard materials and food additives. In the case of liquids containing heterogeneous mixtures or several substances absorbing at the same frequency, an overall absorptivity can be determined either empirically or by application of mixture rules.
2.2.9. Molar Absorptivity The molar absorptivity of a substance has a particular application in the modeling of UV light processing. It is the main optical characteristic observed in all liquid foods undergoing UV treatment. The molar absorptivity (ε, L/mol/m) of the absorbing species is a measure of the amount of light absorbed per unit concentration, or optical density and forms part of the Lambert-Beer ’s law (Eq. 2.23) in a linear relationship between absorbance A, concentration of an
2.3. Final Remarks and Future Recommendations Accurate model prediction requires implementation of the thermophysical properties of all materials involved in a Multiphysics model scenario. The use of constant values for the respective properties generally yields only poor agreement with predictions from actual measured data. Therefore, including the functional dependence of the properties on
Chapter 2
Thermophysical Properties in Simulating Food Processing Technologies
temperature, pressure, and product-specific parameters and variables (e.g., composition and structure) is essential for accurate model prediction. It has been shown that during processing (by technologies explored in this book) thermophysical properties are mainly affected by temperature, pressure, and changes in the process and product parameters, although product parameters such as composition and structural porosity, as a matter of simplification, are generally assumed to be constant. When modeling these processing technologies the governing equations of mass, momentum, and energy conservation have a number of properties in common, including density, specific heat capacity, thermal conductivity, and viscosity. For high-pressure processing the main variables acting are pressure, temperature, and initial composition of the chamber components, which affect the compression heating properties such as density, specific heat capacity, and thermal expansion coefficient, as well as viscosity and thermal conductivity. This has been covered in Chapters 4 and 5, which summarize the changes in these properties at high pressure under low and high temperatures. During microwave processing, properties included in the governing conservation equations and the dielectric properties are only dependent on the temperature, the material, and the selected frequency; they are not affected by the electromagnetic field strength. Chapters 6 and 7 present models wherein these properties vary as a function of temperature and initial product composition. Similarly, for ohmic heating and pulsed electric fields processing, the governing conservation equation properties and the electrical conductivity are only affected by the temperature of a specific material without changing with the variable electric field. Chapters 9 and 11 provide more details on the variation of these thermophysical properties with temperature and composition. Ultrasound processing models (Chapter 12) require governing conservation equation properties, as well as the speed of sound and the sound attenuation coefficient, which are both dependent on temperature and pressure, and frequency in dispersive media. In the case of mixtures they also depend on composition. For dispersions (suspensions and
35
emulsions), the speed of sound and attenuation depend on size and distribution of particles or secondary phase droplets. For systems under cavitation, the strong scattering caused by bubbles dramatically changes both the speed of sound and attenuation. Therefore, these two properties are a complex function of frequency, and cavitation extent. Given that cavitation bubbles are produced (grow and collapse) close to the acoustic source where sound intensity is high, the speed of sound and the attenuation become dependent on the sound field. In addition, the relevant properties in UV processing included in governing conservation equations vary with temperature and material composition, while the absorptivity is only dependent on material composition. Chapters 14 and 15 provide some of the values of absorptivity (absorption coefficient) for various liquid foods. A number of publications have tabulated data and empirical equations describing the variation of thermophysical properties, including the governing conservation equations at atmospheric conditions as a function of temperature and composition of specific food materials and polymers (product and component related). Properties related to other physics phenomena have not been determined to the same extent. As pointed out in this chapter, the main hurdle in developing accurate Multiphysics models is the lack of thermophysical property values. In addition, little information exists in the literature on thermophysical properties at high-pressure conditions. It would be highly desirable that sufficient property data be determined in the form of a database, one that at least shows the values for carbohydrates, proteins, lipids, fiber, and ions present in different foods, as well as values for selected food materials, which may also represent a group of materials. Once this information becomes available, the rule of mixtures can be applied to most of the thermophysical properties reviewed in this chapter, and overall values for particular foods or food blends can be determined. However, it should be pointed out that the speed of sound and sound attenuation coefficients in dispersions do not necessarily obey simple rules of mixtures, given that they may also depend on particle size and distribution of the dispersed phase.
36
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
To satisfy the need for these properties, empirical equations as functions of temperature and pressure are essential for obtaining reliable Multiphysics models. Furthermore, these models will need to account for the composition and structure of the food materials. A way of overcoming this challenge is by providing an open platform for the collection of property data, which will enable the development of accurate models for various food categories. A web site approach similar to the Wikipedia principle could assist in developing an extensive database accessible to the general public. Inter-laboratory validation would then be needed to assure data consistency and accuracy.
Notations Latin Symbols A A B CP c c d f F H I, I0 kC k K L M n P, p Q Q R R r r S T t u, v
Absorbance Area Constant Specific heat capacity Concentration Speed of sound Path length Frequency Force Enthalpy Light intensity Compression heating coefficient Thermal conductivity Constant Length Mass and specific mass Exponential constant Pressure Heat/energy Heat/energy flow Electrical resistivity Gas constant = 8.3142 Distance Radius of dispersed particles Entropy Temperature Time Velocity
— m2 m−1/Hz2 J/kg/K mol/L m·s−1 m Hz N J/kg W/m2 Pa−1 W/m/K m kg or kg/m3 Pa J J/s m/S J/K/mol m m J/K K s m/s
V x y y
Volume Thickness Direction of shear Distance
m3 m — m
Greek Symbols αP α α αo
α exc α th α vis β ρ ε ε ε ε' ε"
φ γ γ η ηp λ τ σ
Thermal expansion coefficient Thermal diffusivity Sound attenuation coefficient Sound attenuation coefficient due to absorption alone Excess attenuation Thermal scattering sound attenuation Visco-inertial sound attenuation Compressibility Density Porosity Dielectric permittivity Molar absorptivity Real part of complex permittivity; dielectric constant Imaginary part of complex permittivity, dielectric loss factor Volumetric fraction = ( c p cv ) Ratio between constant pressure and constant volume heat capacities Shear rate Viscosity Apparent viscosity Wavelength Shear stress Electrical conductivity
K−1 m2/s m−1 m−1 m−1 m−1 m−1 Pa−1 kg/m3 — — L/mol/m — —
— —
s−1 Pa·s Pa·s m N/m2 S/m1
Abbreviations AC PDE CFD SI
Alternating current Partial differential equation Computational fluid dynamics International System of Units (Système international d’unités)
Chapter 2
DSC NIST UV
Thermophysical Properties in Simulating Food Processing Technologies
Differential scanning calorimetry National Institute for Standards and Technology Ultraviolet
Operators d ∂
Differential Partial differential
References Ament WS. 1953. Sound propagation in gross mixtures. J Acoust Soc Am 25:638–641. Aparicio C, Otero L, Sanz PD, Guignon B. 2010. Specific volume and compressibility measurements of tomato paste at moderately high pressure as a function of temperature. J Food Eng. DOI: 10.1016/j.jfoodeng.2010.10.021. Ardia A, Knorr D, Heinz V. 2004. Adiabatic heat modelling for pressure build-up during high-pressure treatment in liquidfood processing. Food Bioproducts Proc 82:89–95. Barbosa-Cánovas GV, Rodríguez JJ. 2005. Thermodynamic aspects of high hydrostatic pressure food processing. In: GV Barbosa-Cánovas, MS Tapia, MP Cano, eds., Novel Processing Technologies, 183–206. New York: CRC Press. Barbosa-Cánovas GV, Ortega-Rivas E, Juliano P, Yan H. 2005. Food Powders. Physical Properties, Processing and Functionality. New York: Springer-Verlag. Barbosa-Cánovas GV, Juliano P, Peleg M. 2007. Engineering properties of foods. In: GV Barbosa-Cánovas, ed., Food Engineering. Encyclopedia of Life Support Systems, 25–44. Oxford: EOLSS Publishers Co Ltd. Barthel R, Nolle AW. 1952. A precise recording ultrasonic interferometer and its application to dispersion tests in liquids. J Acoust Soc Am 24:8–15. Bourne MC. 2002. Texture, viscosity, and food. In: Bourne MC, ed., Food Texture and Viscosity, 1–32. London: Academic Press. Buckow R, Schroeder S, Berres P, Baumann P, Knoerzer K. 2010. Simulation and Evaluation of Pilot-Scale Pulsed Electric Field (PEF) Processing. J Food Eng 101(1):67–77. Chen XD. 2006. Modeling thermal processing using computational fluid dynamics (CFD). In: DW Sun, ed., Thermal Food Processing, 133–151. Boca Raton: Taylor & Francis. Dukhin AS, Goetz PJ, Travers B. 2005. Use of ultrasound for characterizing dairy products. J Dairy Sci 88:1320–1334. Eggers F, Kaatze U. 1996. Broad-band ultrasonic measurement techniques for liquids. Meas Sci Technol 7:1–19. Guignon B, Aparicio C, Sanz PD. 2009. Volumetric properties of sunflower and olive oils at temperatures between 15 and 55C under pressures up to 350MPa. High Press Res 29:38–45. Guignon B, Aparicio C, Sanz PD. 2010. Volumetric properties of pressure-transmitting fluids up to 350 MPa: Water, ethanol,
37
ethylene glycol, propylene glycol, castor oil, silicon oil, and some of their binary mixture. J Chemical Eng Data 55(9): 3017–3023. Harvey AH, Peskin AP, Sanford AK. 1996. NIST/ASTME— IAPSW Standard Reference Database 10, version 2.2. Juliano P, Knoerzer K, Barbosa-Cánovas GV. 2008. High pressure thermal processes: thermal and fluid dynamic modeling principles 35. In: R Simpson, ed., Engineering Aspects of Thermal Processing, 91–158. Boca Raton, FL: CRC Press/ Taylor & Francis. Juliano P, Knoerzer K, Fryer P, Versteeg C. 2009. C. botulinum inactivation kinetics implemented in a computational model of a high pressure sterilization process. Biotechnol Prog 25: 163–175. Junquera E, Ruiz M, Lopez S, Aicart E. 2002. A technique and a method for the continuous, simultaneous, and automatic measurement of density and speed of sound in pure liquids and solutions. Rev Sci Instrum 73:416–421. Kinsler LE, Frey AR, Coppens AB, Sanders JV. 2000. Fundamentals of Acoustics. New York: John Wiley & Sons. Knoerzer K, Regier M, Erle U, Pardey KK, Schubert H. 2004. Development of a model food for microwave processing and the prediction of its physical properties. J Microw Power Electromagn Energy 39:167–177. Knoerzer K, Juliano P, Gladman S, Versteeg C, Fryer P. 2007. A computational model for temperature and sterility distributions in a pilot-scale high-pressure high-temperature process. AIChE J 53:2996–3010. Knoerzer K, Regier M, Schubert H. 2008. A computational model for calculating temperature distributions in microwave food applications. Innov Food Sci Emerg Technol 9:374–384. Knoerzer K, Buckow R, Sanguansri P, Versteeg C. 2010a. Adiabatic compression heating coefficients for high-pressure processing of water, propylene-glycol and mixtures—A combined experimental and numerical approach. J Food Eng 96:229–238. Knoerzer K, Buckow R, Versteeg C. 2010b. Adiabatic compression heating coefficients for high pressure processing—A study of some insulating polymer materials. J Food Eng 98:110–119. Kokini JL. 1992. Measurement and simulation of shear and shear free (extensional) flows in food rheology. Kubota K, Kurisu S, Suzuki K, Matsumoto T, Hosaka H. 1981. Study on the flow equations of sugar, salt and sugar-salt skim milk solutions. J Jpn Soc Food Sci Technol-Nippon Shokuhin Kagaku Kogaku Kaishi 28:186–193. Lamberti N, Ardia L, Albanese D, Di Matteo M. 2009. An ultrasound technique for monitoring the alcoholic wine fermentation. Ultrasonics 49:94–97. Leighton TG. 1997. The Acoustic Bubble. New York: Academic Press. Lighthill J. 1978. Waves in Fluids. Cambridge: Cambridge University Press. Lozano JE. 2007. Thermal properties of foods. In: GV BarbosaCánovas, ed., Food Engineering. Encyclopedia of Life Support Systems, 45–64. Oxford: EOLSS Publishers Co Ltd.
38
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Mathys A, Knorr D. 2009. The properties of water in the pressuretemperature landscape. Food Biophys 4:77–82. Mattea M, Urbicain MJ, Rotstein E. 1989. Effective thermalconductivity of cellular tissues during drying—Prediction by a computer-assisted model. J Food Sci 54:194. McCartney ML, Drouin G. 1977. Moderate-accuracy interferometer for speed of sound measurement in liquids. Rev Sci Instrum 48:214–218. McClements DJ, Povey MJW. 1989. Scattering of ultrasound by emulsions. J Phys D Appl Phys 22:38–47. McClements DJ, Povey MJW, Jury M, Betsanis E. 1990. Ultrasonic characterization of a food emulsion. Ultrasonics 28:266–272. McSkimin HJ. 1957. Ultrasonic pulse technique for measuring acoustic losses and velocities of propagation in liquids as a function of temperature and hydrostatic pressure. J Acoust Soc Am 29:1185–1192. Min S, Sastry SK, Balasubramaniam VM. 2010. Compressibility and density of select liquid and solid foods under pressures up to 700 MPa. J Food Eng 96:568–574. Mohsenin NN. 1984. Electromagnetic Radiation Properties of Food and Agricultural Products. New York: Gordon and Breach Science. Otero L, Molina-Garcia A, Sanz P. 2000. Thermal effect in foods during quasi-adiabatic pressure treatments. Innov Food Sci Emerg Technol 1:119–126. Otero L, Ousegui A, Guignon B, Le Bail A, Sanz PD. 2006. Evaluation of the thermophysical properties of tylose gel under pressure in the phase change domain. Food Hydrocolloids 20:449–460. Patazca E, Koutchma T, Balasubramaniam VM. 2007. Quasiadiabatic temperature increase during high pressure processing of selected foods. J Food Eng 80:199–205. Povey MJW, Mcclements DJ. 1998. Ultrasonics in food engineering. Part I: Introduction and experimental methods. J Food Eng 8:217–245. Rahman S. 1995. Food Properties Handbook. Boca Raton, FL: CRC Press. Rao MA. 2007. Rheology of Fluid and Semisolid Foods: Principles and Applications. New York: Springer. Rasanayagam V, Balasubramaniam VM, Ting E, Sizer CE, Bush C, Anderson C. 2003. Compression heating of selected fatty food materials during high-pressure processing. J Food Sci 68:254–259.
Sahin S, Sumnu SG. 2006. Physical Properties of Foods. New York: Springer. Salvadori VO, DeMichelis A, Mascheroni RH. 1997. Prediction of freezing times for regular multi-dimensional foods using simple formulae. Food Sci Technol Lebensmitt Wiss Technol 30:30–35. Schubert H, Regier M. 2005. Introducing microwave processing of food: principles and technologies. In: H Schubert, M Regier, eds., The Microwave Processing of Foods. Cambridge: Woodhead Publishing Limited. Servant G, Laborde JL, Hita A, Caltagirone JP, Gerard A. 2001. Spatio-temporal dynamics of cavitation bubble clouds in a low frequency reactor: Comparison between theoretical and experimental results. Ultrason Sonochem 8:163–174. Shao YW, Zhu SM, Ramaswamy H, Marcotte M. 2007. Compression heating and temperature control for high pressure destruction of bacterial spores: An experimental method for kinetics evaluation. Food Bioprocess Technol. doi: 10.1007/ s11947-008-0057-y Shoitov YS, Otpushchennikov NF. 1968. Pressure dependence of the speed of sound in liquid. Izvestiya VUZ Fisika 11: 137–139. Steffe JF. 1992. Rheological Methods in Food Process Engineering. East Lansing, MI: Freeman Press. Tabilo-Munizaga G, Barbosa-Cánovas GV. 2005. Rheology for the food industry. J Food Eng 67:147–156. Trujillo FJ, Knoerzer K. 2009. CFD modelling of the acoustic streaming induced by an ultrasonic horn reactor. In: Seventh International Conference on CFD in the Minerals and Process Industries. Melbourne, Australia. Vitali AA, Rao MA. 1984. Flow properties of low-pulp concentrated orange juice—Serum viscosity and effect of pulp content. J Food Sci 49:876–881. Welti-Chanes J, Vergara-Balderas F, Bermudez-Aguirre D. 2005. Transport phenomena in food engineering: Basic concepts and advances. J Food Eng 67:113–128. Zhang H. 2007. Electrical properties of foods. In: GV BarbosaCánovas, ed., Encyclopedia of Life Support Systems (EOLSS). Developed under the Auspices of the UNESCO, 115–125. Oxford, UK: Eolss Publishers. Zhu S, Ramaswamy HS, Marcotte M, Chen C, Shao Y, Le Bail A. 2007. Evaluation of thermal properties of food materials at high pressures using a dual-needle line-heat-source method. J Food Sci 72:E49–E56.
Chapter 3 Neural Networks: Their Role in High-Pressure Processing José S. Torrecilla and Pedro D. Sanz
The main objective of a mathematical model is to reproduce the corresponding process performance and/or estimate important variable values. Because of this, the modelization of processes is useful mainly as a previous stage in the design of equipment. With this aim, although detailed knowledge of the process is not always required, the input and output variables of the system to be studied should be known. Here, two such methods usually used to design this type of models are described, viz. models based on neural networks (NNs) and macroscopic models. Although successful applications will be shown here, the presented models have to be adjusted prior to applying them to new systems.
3.1. Brief History of NNs In the nineteenth century, Alexander Bain and William James established the foundation of modern NNs, which later, in the middle of the twentieth century, were developed by Warren McCulloch and Walter Pitts (McCulloch and Pitts 1943). These algorithms were further developed during the ensuing two decades, but in the 1960s, as a result of the exaggeration of successful results, bitter critique focused mainly on the capability of NNs was published and
research tasks were delayed for nearly a decade. In 1969, Minsky and Papert published a book titled Perceptrons, which was partially responsible for the reinitiation of NN research activity (Minsky and Papert 1969). Shortly afterwards, the backpropagation (BP) algorithm, one of the most important components of NN algorithms, was presented by Werbos and developed by Rumelhart and his colleagues among other research groups (Werbos 1974; Rumelhart et al. 1986). In the 1980s, Holpfield’s publications stimulated NN investigations (Hopfield 1982, 1984). In the last two decades, algorithms that handle and process information in a way similar to the human brain such as NNs and fuzzy logic have been developed (Chen 1996). In particular, the rapid development of NN algorithms and their numerous applications in commercial and scientific sectors are mainly based on the notable growth in computer technology. Now, NN technology is used in food science, chemical engineering, process control, medical diagnosis, forensic analysis, weather forecasting, financial applications, investment analysis, and others. In all these applications, depending on their requirements, NNs can be applied to tasks related to classification and/or prediction activities (Huang et al. 2007).
Innovative Food Processing Technologies: Advances in Multiphysics Simulation, First Edition. Edited by Kai Knoerzer, Pablo Juliano, Peter Roupas, and Cornelis Versteeg. © 2011 by John Wiley & Sons, Ltd. and Institute of Food Technologists. Published by John Wiley & Sons, Ltd. ISBN: 978-0-813-81754-5
39
40
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
INPUTS
WEIGHTS
0.5
1
ACTIVATION FUNCTION
x
I iWi i
0.7
x= –0.9
TRANSFER FUNCTION
f ( x)
1 1 e
x
OUTPUTS
f(x) = –0.289
–2
Figure 3.1. Schema and an example of the calculation procedure of an artificial neuron (x, I, i, and f(x) are the activation function, input value, layer, and sigmoid function as transfer function, respectively).
3.2. Basis of NNs Although biological neurons are much more complicated than artificial neurons, the design and development of artificial neurons have been inspired by biological cells. A biological neuron consists of dendrites, soma, axon, and synapses. The signal is received by dendrites, processed in the soma or cell body and the output is emitted by the axon and transmitted to other neurons by synapses. An artificial neuron receives signals, which are processed in the neurons by mathematical algorithms (a combination of linear or nonlinear algorithms), and the output information is then sent to another neuron as input or is used directly as a network result. A schematic of an artificial neuron and an example of a calculation procedure are shown in Figure 3.1. The connectivity of artificial neurons emulates the biological neurological system, which is in most cases to design an NN; artificial neurons are joined and depending on the connections between them, different types of NNs can be defined, for example, neurons may or may not receive information back from the next layers, forming NNs called feedback or feedforward networks, respectively, whereas the recurrent networks, once the signal is received in a neuron from a given layer, are communicated to other neurons in the same layer before sending it onto the next or last layer. In most cases, the artificial neurons are arranged in layers. Each connection is controlled by parameters called weights. As some input signals may be more important than others, to obtain the best result (the maximum accuracy possible, vide infra), the weight
values must be optimized using real data from the system to be modeled (Huang et al. 2007). The optimization of the weights is commonly called the learning process, which is the most important process in the design of NN. Depending on the NN type, their weights can be optimized by supervised or unsupervised methods. The most common learning process used is the supervised method, which requires a database comprising input and target output values. For instance, to optimize the weights of a feedforward network, a supervised learning process such as a BP algorithm is normally used. The unsupervised learning process requires only input information. Kohonen’s selforganization map is a network that follows an unsupervised learning process (vide infra). Throughout the chapter, every statistical result has been calculated using estimated values worked out by the NN models and the real values from the external validation samples.
3.2.1. BP Algorithm The BP (also called the retro-propagation of error) is a common method used to optimize the weights of supervised networks. These algorithms can be used to optimize the weights of NNs with fully or partially interlayer connections (no intra-layer connection). Basically, the information is inputted into an NN and is fed forward throughout hidden and output layers to calculate a response. The calculation process in each neuron of the hidden and output layers consists of activation and transfer functions.
Chapter 3
Neural Networks: Their Role in High-Pressure Processing
41
The activation function, Equation 3.1, means that the input data to each neuron are multiplied by weight; the result, xk, is fed into a transfer function. The sigmoid or hyperbolical tangent function is the most commonly used transfer function, Equations 3.2 and 3.3, respectively. The calculated value, yk, is the output of the considered neuron. This calculation procedure is shown in Figure 3.1.
calculated. When every data set of the learning sample has been used, a cycle is finished and another begins with the first data set of the aforementioned database (Torrecilla et al. 2009a). A more detailed explanation can be found elsewhere (Fine 1999; Arbib 2003).
∑w
The networks optimized by the unsupervised learning process are able to learn from the input signals to ascertain their regularity without knowing in advance what the desired outputs are. Although unsupervised learning may provide more effective solutions than supervised learning (Torrecilla et al. 2009b), unsupervised learning processes are still in an early trial stage, which can only be used for some simple applications (Huang et al. 2007). Due to the fact that one of the most representative, interesting, and influential unsupervised networks is Kohonen’s self-organization map (Kohonen 1987), the learning process of this type of NN is exposed here. Self-organizing maps (SOMs), Kohonen’s selforganization map, or Kohonen’s NN can learn to detect irregularities and correlations in their input data and adapt their future responses to that input accordingly, that is, they are able to recognize groups with similar characteristics (Kohonen 1987; Demuth et al. 2005). The architecture of SOM models is shown in Figure 3.3. This is composed of two layers, viz. input and competitive layers. Every circle and arrow represents a neuron and weight, respectively, that is, there are as many weights as arrows and the number of neurons is equal to the product of the width and length of the competitive layer. In order to represent the whole input database, the neurons, defined by weight vectors, look for the best place in the competitive layer during the learning process (Figure 3.3). The weights of the SOM model optimization can be summarized in five stages:
xk =
jk
⋅ yj
(3.1)
j =1
⎛ 1 ⎞ yk = f ( x k ) = ⎜ ⎝ 1 + e − xk ⎟⎠
(3.2)
⎛ 1 − e −2 xk ⎞ yk = f ( x k ) = ⎜ ⎝ 1 + e −2 xk ⎟⎠
(3.3)
where i, j, and k subscripts are the input, hidden, and output layers, respectively. Given that the optimum weights are calculated by differential calculations, all algorithms that compose the BP algorithm (activation, transfer function) must be differentiable (vide infra). Then, this output is compared with the real or known value (rk) and the mean square error value (MSE) is calculated, Equation 3.4. MSE =
1 N
N
∑ (r − y ) k
k
2
(3.4)
k
where N is the number of neurons in the output layer. Once the MSE has been calculated, the optimization of the weight begins. The weights of the hidden and output layer connections are first optimized. An example of the forward calculation procedure and the equations required to optimize every weight are shown in Figure 3.2. As can be seen, two different groups of equations are used to optimize the weights from hidden-output layers and inputhidden layers. The determination of the level of generalization of the NN is performed once the weights have been optimized. For that purpose, the NN is tested by new databases commonly called verification. In this way a testing or an internal validation sample and an external validation sample is obtained. That is, the optimized NN calculates the output values using a new database and the prediction error is then
3.2.2. Unsupervised Learning Process
1. Assign random values to the weights. 2. A data set from the learning sample is presented to the SOM. 3. The neuron with the least Euclidean distance between its weights and data set (D) is selected (Eq. 3.5). This is called the winning neuron.
42
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Forward calculation
1
0.1
Output value
0.3 1
2
0.2
0.5
0.4
1
0.5
0.6
Weights 0.1
Weights 0.1
0.2
Mean square error
0.9
Input values
Real values
Input layer
Hidden layer
Output layer
Backpropagation Error o
y ko (1 y ko )w jk ( y ko
k
1
Error o y ij (1 y ij ) y i
w (t 1) w (t ) Error
2
o k
R)
o k
o k
y (1 y )w jk ( y
w (t 1) w (t )
o k
1
w(t 1)
w(t) µ Error y k (1 y k ) y jk
1
0.1
R)
Mean square error
Error o y ij (1 y ij ) y i
Figure 3.2. Forward calculation and backpropagation procedures (w, t, Error, Error o, μ, R, i, j, and k are weight, time, MSE, and MSE retro-propagated, learning coefficient, real values, input layer, hidden layer, and output layer, respectively).
4. The weights of the selected neuron are optimized so that they become more similar to the input vector (Eq. 3.6). 5. The weights of the neighboring neurons are also optimized but with proportionally less Euclidean distance to the winning neuron Equation 3.7. S
Input values
D j = X − Wj =
∑ (X − W ) ; 2
i
ij
j = 1 ,2 ,… , N
i
(3.5) W j (n) = W j (n − 1) + Lr ⋅ [ X (n − 1) − W j (n − 1)] (3.6)
Input layer Figure 3.3. Schematic diagram of self-organizing map model.
W j ( n) = (1 − Lr ) ⋅ W j ( n − 1) + Lr ⋅ X ( n − 1) (3.7) where W, n, X, Lr, N, and S are the weights, iteration of a given cycle, input vector, learning rate, number
Chapter 3
Neural Networks: Their Role in High-Pressure Processing
of weights of the SOM, and number of data set of the learning sample, respectively (Demuth et al. 2005; Raju et al. 2006). The process is iteratively repeated. A cycle is finished when the entire database has been presented to the SOM (Fonseca et al. 2006). Once the SOM model has been trained, it is able to extract the relevant information in order to classify new input vectors (which are interpolated in the learning range) and the model can classify the input data according to how they are grouped in the input space, that is, the input data can be adequately represented. A more detailed explanation can be found elsewhere (Arbib 2003).
3.3. How NNs Are Helping the Chemical Industry
43
algorithm are necessary. In order to validate the NN algorithms as a powerful chemometric tool, a system based on low concentrations (less than 15 ppm) of toluene, heptane, and 1-ethyl-3-methylimidazolium ethylsulfate and 1-butyl-3-methylimidazolium methylsulfate ILs in acetone was selected. The imidazolium ring of both ILs and toluene are ultraviolet (UV) active in the same region. But the UV-visible spectroscopy also fulfilled all the aforementioned conditions. For those reasons NN algorithms can be reliably tested to solve overlapping effects of quaternary mixtures. In this process, the mean prediction error (MPE; Eq. 3.8) was less than 2.5% and the mean correlation coefficient was greater than 0.95. MPE =
1 N
∑ n
rn − yn ⋅ 100 rn
(3.8)
Five applications of NNs in chemical engineering are presented in this section in order to show the wide applicability of NN models: (1) quantification of chemicals in quaternary mixtures; (2) solving overlapping effects in biosensors; (3) process control using two NNs; (4) filter of experimental signals; and (5) geographical classification of crude oils.
In Equation 3.8, N, yn, and rn are the number of observations, model estimation, and real value, respectively. Therefore, this approach can be adapted to deconvolute the contribution of each chemical. As a result, in the IL field, this approach is very interesting for further applications to digital control, or measurement devices (Torrecilla et al. 2007a, 2009a).
3.3.1. Quantification of Two Ionic Liquids (ILs), Heptane, and Toluene
3.3.2. Solving Overlapping Effects in Biosensor
ILs are a class of low-temperature molten salts consisting of an organic cation and inorganic or organic anion. In recent years, ILs have attracted increasing attention as replacements for conventional organic solvents in catalysis, separation processes, electrochemistry, and many other fields. Recently, ILs are being measured using interpolation in physicochemical properties (density, viscosity, refractive index, etc.), proton nuclear magnetic resonance, gas chromatograph, and others. However, these procedures are not adequate to measure/control on-line chemical processes (extraction, distillation, etc.) because of the time required to prepare samples. Given the importance of these processes, an analytical technique with a sample preparation time less than the sampling time of the process and a reliable
The major obstacle in amperometric detection of glucose in real samples is the interference arising from electrooxidize substances such as ascorbic and uric acids existing in a measured system. In Torrecilla et al. (2008a), an amperometric biosensor based on a colloidal gold—cysteamine—gold disk electrode with an enzyme glucose oxidase and a redox mediator, tetrathiafluvalene, co-immobilized atop the modified electrode was used for the simultaneous determination of glucose and ascorbic and uric acids in ternary mixtures. The concentrations of these chemicals were between 0 and 1 mM. In light of these results (MPE < 1.7% and R2 > 0.99), the NN model is able to solve the interferences between glucose and ascorbic and uric acids, without any chemical pretreatment.
44
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
3.3.3. Process Control Using Two NNs A control system based on a combination of two NNs was designed for the control of pH in the neutralization process of acidic liquid streams. The first NN is a plant neural model that predicts future pH values from past/present values of pH and valve stem positions and future values of valve stem positions. The second NN is a plant inverse neural model that calculates future valve stem positions from present/past values of pH and valve stem positions and future values of set points. The performance of the controller was studied first by numerical simulation. The controller was further implemented in a continuous stirred tank reactor in which the neutralization of acetic and propionic acids with sodium hydroxide was performed. The controller requires off-line and on-line learning of the direct NN and on-line learning of the inverse NN. The off-line training of the direct NN was made by numerical simulation of the neutralization process in openloop conditions. The adaptive properties of the controller were shown by means of the changes in time of the network weights. The effect of adaptation of weights when noise is present was explored and, for the range of conditions studied, the controller maintains its capacity of control for at least 100 hours. The controller can be applied to processes with a short delay time. The input layer of each NN should contain a sufficiently large number of nodes to take into account the number of past values necessary to cover the maximum delay time expected for the plant. If a maximum delay is assumed in the model but the actual delay time of the plant is zero or shorter than this maximum, the controller has practically the same performance as in the system with an actual delay equal to the maximum assumed. The experimental validation of the controller showed that the control efficiency is good only for perturbations that do not involve strong buffering changes (e.g., for small perturbations of set point, flow, and concentration of acids). Under these conditions, the NNs are able to adapt their weights on-line and to control perturbations never seen before. The controller performance was also good after successive buffering changes between the two
buffers. A detailed description of this controller can be found in the literature (Palancar et al. 1998).
3.3.4. Filter of Experimental Signals In this example, an integrated NN/thermogravimetric analyzer (TGA) is designed to filter a noisy signal from TGA equipment. The data collected (sample weight loss as function of sample temperature) from the TGA equipment were transferred into an NNtrained computer for modeling and filtering of the output. The NN/TGA filter is composed of a model (NNM) and a filter (NNF) of the system both based on feedforward networks. The NNM was designed and optimized to estimate the sample weight as a function of the temperature of the sample. Its topology consists of two input nodes (temperature of the sample and noisy signal) and output with noise. The NNF was designed to filter a noisy signal from TGA equipment. It was made up of two inputs that correspond to each variable and an output that calculates the signal without noise. To evaluate the competence of the optimized NN/TGA filter, a random noise was added to an experimental signal without noise. Such an integrated NN/TGA filter is capable of filtering the noisy TGA output signal based on the models and patterns created (MPE < 0.3%), without any previous phenomenological knowledge. This is very interesting for further applications to digital control, or measurement devices. This importance is even greater when the NN/TGA filter is applied to ILs where the knowledge of their properties is scarce. A detailed description of this filter can be found in the literature (Torrecilla et al. 2008b).
3.3.5. Geographical Classification of Crude Oils In environmental disasters caused by the spillage of crude oil, ascertaining the geographical origin of the crude oil by analysis is relatively simple. Fonseca et al. (2006) have designed an unsupervised network based on an SOM that can classify samples of crude oils on the basis of gas chromatography-mass
Chapter 3
Neural Networks: Their Role in High-Pressure Processing
spectroscopy (GC-MS) descriptors. To optimize the network, two databases were used; one of them comes from the Instituto Hidrográfico (Lisbon, Portugal) and the other one from the European Crude Oil Identification System (EUROCRUDE). Once the network was optimized, correct estimations were obtained in 70% of the tested sets in the verification process. Assembling four SOMs, this percentage increased to values higher than 94%. Equally good predictions were obtained for a small test set of weathered samples. This investigation added value to the GC-MS descriptors already in use for practical analytical work.
3.4. The Role of NNs in the Food Industry The main advantages and disadvantages related to NN applications in some food sectors such as olive oil, wine, waste treatment, food adulterations, and vitamins will be summarized here.
3.4.1. Determination of Polyphenolic Compound Concentration in Olive Oil Mill Wastewater The waste generated during the manufacture of extra virgin olive oil (EVOO) has a serious environmental impact due to its high content of organic substances (sugars, tannins, polyphenols, polyalcohols, pectins and lipids, etc.). It is known that caffeic acid (CA) and catechol (CT) are two of the major contributors to the toxicity of these wastes. Given their electrochemical characteristics, a laccase biosensor (LB) is commonly used to determine CA and CT. Because of the similarities in the oxidized species produced, the amperometric signal overlapping in the reduction voltammograms is high, and therefore, a powerful tool is required to differentiate this signal. Once the NN was optimized, it was externally validated using real concentrations taken from three different olive oil mills in Spain (Almendralejo, Badajoz; Martos, Jaén; Villarejo de Salvanes, Madrid). The MPE, Equation 3.8, was less than 0.5% and the correlation coefficient was higher than 0.99. These statistical results are even better and more selective than other non-portable commercial
45
analytical equipment. Therefore, the integrated NN/ LB system was shown to be an adequate approach to estimate simultaneously both hazardous chemicals in olive oil mill wastewater (Torrecilla et al. 2007b).
3.4.2. Discrimination of Wines Using unsupervised networks, Masoum et al. (2006) determined that polyphenol extracts from wines are not only characteristic of the grape variety but also characteristic of the year of harvest (vintage) and geographical origin. Learning vector quantization (LVQ) with orthogonal signal correction (OSCLVQ) and partial least squares discriminant analysis (PLS-DA) techniques were used. An LVQ network correctly classified the polyphenols extracted from the wines depending on three important characteristics: grape variety, type of soil, and year of harvest obtaining percentages of correct classification of 93, 89, and 85%, respectively. The OSC–LVQ method has been shown to be a slightly better pattern recognition technique in comparison with OSC–PLS-DA when applied to two-dimensional (2D) nuclear magnetic resonance spectra. This unsupervised network has not only been applied to classify wines but also to demonstrate the nonlinear relation between the aforementioned characteristics and the type of wines.
3.4.3. Identifying and Detecting Adulterations In recent decades, due to the high price of EVOO, an appreciable incidence of adulteration has been detected. The substitution or adulteration of EVOO with cheaper ingredients is not only an economic fraud but may also have severe health implications for consumers, an example being the Spanish toxic oil syndrome. Two unsupervised networks based on an SOM and LVQ network models have been tested for the identification of edible and vegetable oils and to detect adulteration of EVOO. A bibliographical database for developing learning process and internal validation, and six other different databases,
46
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
from bibliographical sources, were used to perform their external validation. The results showed that less than 3 and 5.5% of the samples were misclassified. The models’ performances were analyzed by the number of misclassifications. In the worst of the cases, the SOM and LVQ models were able to classify more than the 94% of the samples and to detect adulterations of EVOO with corn, soya, sunflower, and hazelnut oils when their oil concentrations were higher than 10, 5, 5, and 10%, respectively. In light of these results, both models showed to be adequate to classify these studied samples in 13 types of vegetable oils (Torrecilla et al. 2009b).
3.4.4. Determination of Carotenoid Concentrations in Foods Due to their antioxidant activity, carotenoids show a strong correlation between their intake and a reduced risk of some diseases, such as cancer, atherogenesis, bone calcification, eye degeneration, and neuronal damage. Given that the lycopene and β-carotene are active in the same region of UV-vis spectroscopy, their determination by linear algorithms is not suitable (Torrecilla et al. 2008c). In order to use a fast, simple analytical technique such as UV-vis spectroscopy, a nonlinear algorithm based on NN algorithms was applied. Using the absorbance of mixtures composed of lycopene and β-carotene with concentrations between 0.4 and 3.2 μg/mL and their respective concentrations distributed following an experimental design, the NN (feedforward network) was optimized. Once the NN model was optimized, NN/ UV-vis spectroscopy was applied to determine the concentration of both chemicals in foods related with tomatoes. The MPE was 50 times lower than when a linear model was used in place of the aforementioned nonlinear algorithm (MPE < 1.5%; R2 > 0.99).
3.5. NNs in High-Pressure Processes In light of the aforementioned properties and applications, a detailed description of several successful NN applications in the HP sector will be shown
highlighting their main advantages and the principal differences between NN and other known types of models. In the last decade, some research groups have investigated NN estimation capability partially connected with the food sector, for example, Si-Moussa et al. (2008) have estimated the vapor-liquid equilibrium of binary systems composed of carbon dioxide and chemicals that are applicable to the cosmetic and food sectors. But, to the best of our knowledge, in the food sector, the number of references directly connected with high pressure processing (HPP) processes and NN algorithms is scarce. Here, two successful applications of NN are detailed.
3.5.1. Estimation of Freezing Temperature of Foods at High Pressure Freezing/melting of aqueous systems is a phenomenon considered in many disciplines, not only food technologists but also in all sectors interested in the conditions of ice formation such as geologists, oceanographers, meteorologists, astrophysicists, biologists, and engineers. Compared with traditional processes such as air blast freezing, pressure-shift freezing produces smaller ice crystals with a uniform distribution in the whole product (Otero and Sanz 2000; Zhu et al. 2005). So, its texture is better preserved and drip losses upon thawing are reduced (Fuchigami et al. 2002; Le Bail et al. 2002; Urrutia-Benet et al. 2007). The main difficulties in developing this emerging technology from a laboratory to an industrial scale lie in process parameter optimization and energy cost minimization. To deal with these two problems, heat transfer should be modeled (Boillereaux et al. 2003; Otero and Sanz 2003; Pham 2006). For that purpose, the initial freezing point appears as a fundamental variable. At this point, all thermophysical properties change suddenly with the formation of ice (freezing process) or its melting (thawing process). For example, the specific heat capacity, also required for heat transfer simulation, changes from 2,046.5 J/ kg/°C in solid to 3,857.4 J/kg/°C in liquid state at the freezing point of water at 100 MPa (−8.8°C) (Otero et al. 2002a). The thermophysical properties
Chapter 3
Neural Networks: Their Role in High-Pressure Processing
depend on the ice content that can be calculated as a function of the initial freezing temperature (Fikiin 1998). Accurate knowledge of the initial freezing temperature is also essential to minimize the energy required to reach freezing/thawing conditions. Finally, its determination allows the discovery of metastable regions and explores new possibilities for process optimization (Schlüter et al. 2004; Urrutia Benet et al. 2006). Aqueous solutions and food models are often used to simulate food. In this way, the water (P, T )-phase diagram of Bridgman (1912) is routinely applied to decide on the operating conditions for high-pressure food freezing/thawing processes. In addition to the empirical equations proposed by Wagner et al. (1994), the freezing temperatures of water can be computed up to 20 GPa for different ice polymorphs. Sanz et al. (2004) have described qualitatively the phase diagram of water until about 10 GPa by means of computer simulation. For aqueous systems, the (P, T )-phase diagram has seldom been determined. The experimental initial freezing point at high pressure has been measured for sucrose and sodium chloride solutions by Guignon et al. (2005). Those authors provided and tested different equations to calculate the initial freezing temperature of food under pressure. As an alternative to traditional calculations, an NN was also designed and described in the manuscript. In addition, new experimental data were presented for gelatine gels (with and without sucrose), for sucrose solutions with hydrocolloids (guar gum or xanthan and locust bean gum mix), for tylose gel as food models, and for broccoli. These values, together with data collected from the literature, were used to evaluate the aforementioned linear and nonlinear algorithms (Guignon et al. 2008). Different models have been used in order to predict the freezing temperature as a function of pressure: empirical models such as a polynomial equations, the Simon-like equation, and the linear additive model; NN models; and theoretical models such as Raoult’s modified law and the Robinson and Stokes’ equation extended to high pressure conditions. From the results obtained it was shown that NNs are an interesting alternative to obtain the freezing temperature at any given pressure of any aqueous
47
system knowing only its water activity (within its working range). Calculated freezing temperatures differ from those measured by approximately 0.3°C. The NN is even able to reproduce literature data within a 95% confidence interval when the water activity of the substance is within the training range.
3.5.2. Application of NN on Thermal/ Pressure Processing Recently, HPP technology has been introduced in the food industry mainly to control the microbiological and/or enzymatic activity of food products. As it is known, hydrostatic pressure acts instantaneously and uniformly throughout a mass of waterrich food independently of its size, shape, or composition, which has been described as a possible advantage of HPP processing over traditional thermal processing. On the other hand, it is important to recognize that pressurization/depressurization induces a temperature change due to the work of compression/expansion in both the food and the pressure-transmitting fluid. The value and sign of these temperature changes depend on pressure and temperature conditions, the rate of compression/ decompression, the composition of the food, and the type of the pressure-transmitting fluid (Otero et al. 2000). For instance, in vegetable oils, a pressure change of 200 MPa induces temperature changes higher than 20°C (Shimizu 1992). Therefore, as each pressure treatment implies a thermal effect, pressure and temperature are not independent. Moreover, during compression, temperature changes in the sample and the pressure-transmitting fluid will be different due to their different thermophysical properties. As a result, during the holding time at high pressure, heat transfer phenomena are taking place between the sample, the pressure medium, the pressure vessel, and the surroundings leading to thermal gradients in the treated product. Hence, when high hydrostatic pressure is applied to foodstuffs to control their microbiological and/or enzymatic activity, it is important to bear in mind that the obtained results depend both on the pressure applied and the temperature during the treatment.
48
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Taking into account that typical pressure treatment times for extending the shelf life of food could range from a few minutes up to half an hour, the whole pressure treatment or—at least an important part of it—can take place at a temperature quite different from the initial temperature (Otero et al. 2002b). A pressure increase of 450 MPa may result in a sample temperature increase of almost 15°C, and nearly 15 minutes (depending on the insulation properties of the vessel) is necessary to re-reach the target temperature in the sample. If the treatment time to be used were shorter, the complete treatment would have been performed at a higher temperature than desired. Hence, it is essential to know both the thermal and the pressure evolution in the treated sample to obtain reproducible results. Unfortunately, this has not always been recognized and many researchers do not control/document temperature conditions during pressure treatments and attribute the obtained results directly to the pressure applied and the initial product temperature. Some authors have shown the importance of the thermal effects on inactivation studies at HPP conditions (De Heij et al. 2002. Ting et al. 2002) and recommended reporting the pressure and temperature history in all studies. If this is not possible, those authors suggest reporting the extreme values of pressure, temperature, and time as indicators of the pressure and temperature evolution. Another alternative is based on the modelization of the temperature and/or pressure profile. Some attempts have been made by different authors to model the thermal behavior of food during HPP (Otero and Sanz 2003). Among the many difficulties met in this way, the main problem of physically based models is the almost complete lack of appropriate thermal properties of foodstuffs and pressuretransmitting fluid at high pressure to date. Trying to overcome this obstacle, Torrecilla et al. (2004) have shown the capability of NNs in modeling the thermal behavior of food during HPP without the requirement of thermophysical properties. As a consequence of this work and in trying to overcome the aforementioned difficulties, an NN able to predict the temperature changes in a food sample after pressurization and the time needed for thermal
re-equilibration in the HPP system was designed (Torrecilla et al. 2005). Two years later, the improvement of the NN performance by varying the number of neurons in the hidden layer, selecting the architecture and the learning coefficient with the highest predictive ability, and taking into account the effect of the training algorithm was carried out (Plumb et al. 2005; Torrecilla et al. 2007c). A priori knowledge of the above-mentioned variables is very useful in designing and optimizing pressure food processes because these variables provide, together with the programmed pressure, a proper notion of the thermal evolution of the sample during the pressure treatment (Ting et al. 2002). In Torrecilla et al. (2007c), a correct selection of the training algorithm and an optimized NN for thermal/pressure food processing has been used. In this work, different NNs trained with different learning functions have been assessed with respect to their predictive ability. From this assessment, the Levenberg-Marquardt algorithm was identified as the best learning function. The gradient descent, conjugate gradient, and Bayesian regularization algorithms implemented by MATLAB™ (The MathWorks Inc., Natick, MA) and used in previous works gave poorer results. In Torrecilla et al. (2005), an NN was developed for thermal/pressure food processing without any previous selection of the most adequate training algorithm, that is, assuming the default option of the NN computational package (batch gradient descent with a user-defined learning rate). In this case, the MPEs (1.6 and 0.95% for temperature and time predictions, respectively) were significantly higher than those found in Torrecilla et al. (2007c). Also, the correlation coefficients (R2) clearly show better predictive ability of the NN trained after a correct selection of the learning function (0.99 and 0.99 vs. 0.98 and 0.99 for temperature and time predictions, respectively). Therefore, it is evident that a correct selection of the training algorithm allows maximizing the predictive ability of the NN, as Plumb et al. (2005) pointed out. Thus, not only the network architecture (as is frequently mentioned in the literature), but also the training algorithm must be optimized in order to obtain the most predictive models.
Chapter 3
Neural Networks: Their Role in High-Pressure Processing
Moreover, once the NN is optimized, a large number of combinations of processing conditions can be evaluated after a short computing time and this gives an important advantage when designing and optimizing high-pressure processes in the food industry (Torrecilla et al. 2007c).
3.6. A Macroscopic Model for Thermal Exchange in an HPP System The importance of macroscopic models is based on their applicability to many systems. For instance, macroscopic models can be used (Otero et al. 2002a) to analyze all the thermal exchanges in an HPP system, evaluate the impact of the different components, and therefore allow regulation of the temperature in a given process.
3.6.1. Simple Representation and Modeling of Thermal Processes in HPP Treatments To simplify processes and for practicality purposes, it could be assumed that thermal processes are governed by sets of linear or nonlinear algebraic equations and linear and nonlinear differential equations. In those cases there are several more or less adapted tools for its mathematical modeling. Among them there is the SIMULINK package, which is a toolbox of MATLAB™. It is an icon-driven interface for the construction of a block diagram representation of processes. A simple graphical representation of a process composed of an input, the system, and an output is shown in Figure 3.4. Each single part or component of an HPP system involved in a heat transfer process can also be represented by a block diagram. Considering a thermoregulation device as a single part, this device should be connected to an HP vessel in order to maintain a
Input
System
Figure 3.4. Block diagram of a process.
Output
49
programmed temperature in the vessel during HPP (Figure 3.5). How the fluid (water in this case) is continuously circulating through a closed circuit from the thermoregulation bath is shown in Figure 3.5. The block diagram of the thermoregulation bath working with two independent coolers and a heater is represented in Figure 3.6. Let us suppose that it is intended to reach 60°C as the temperature in the sample situated in the HPP vessel. The heat flow from the walls of the thermoregulation fluid container is also represented. In addition, the external temperature of the bath (20°C in this case) and the temperature of the sample situated in the HPP vessel are both accounted for. In order to evaluate each partial heat balance, a set of different mathematical operators is shown in Figure 3.6. Each integration step, the current temperature of the water circulating through the heat exchanger, as shown in Figure 3.5, is checked, bearing in mind the programmed temperature for the sample in the HPP vessel. Suitable controls on the thermoregulation activities have to be performed accordingly, for example, by switching the coolers “on” or “off” during the continuous running of the heater. Assuming that the steady-state temperature of the sample is the same as the corresponding one for the pressure-transmitting fluid Tf1(°C) that is situated in the HPP vessel and considering also that the vessel is long enough, the rate of heat variation q into the vessel is governed by Equation 3.9 q=
2π H (T f 1 − T f 2 ) ⎡ ⎛ ri +1 ⎞ ⎤ n ln ⎜ ⎢ 1 ⎝ ri ⎟⎠ 1 ⎥ + + ⎢ ⎥ λi r2 h2 ⎥ ⎢ r1h1 i =1 ⎢⎣ ⎦⎥
(3.9)
∑
where H is the height of the vessel (m), Tf 2(°C) the temperature outside the vessel, ri and λi the radius (m) and the thermal conductivity (Wm–1/°C) of the different layers of the vessel, respectively, h1 and h2 the inside and outside surface heat transfer coefficients (Wm–2/°C) of the vessel, respectively, and r1 and r2 the inside and outside radius of the vessel, respectively (Kakaç and Yener 1985).
50
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
High-pressure cylinder Second steel cylinder Thermal isolation 100 Thermoregulation circuit
180 300
300 340 Pressuretransmitting fluid High-pressure pump
Thermoregulation bath
Figure 3.5. Thermoregulation as a part of a high-pressure system.
On the other hand, the temperature variation due to a compression or an expansion also has to be considered. Such effects are governed by dT α ⋅ Tk ⋅ V = dP Cp
(3.10)
being α (°C–1) the thermal expansivity coefficient of the sample filling the HPP vessel, V its specific volume (m3/kg, the inverse of the density), and Cp its specific heat capacity (J/kg/°C). Taking this contribution into account (Otero et al. 2007), the initial block diagram shown in Figure 3.6 has to be extended accordingly as represented in Figure 3.7.
3.6.2. Using Macroscopic Models in HPP This model takes into account the thermal exchanges performed in the thermoregulation bath and in the pipes between the bath and the coil surrounding the HPP vessel. In fact, the model represented in Figure 3.7 (Otero et al. 2002a) corresponds to the case of a pilot plant HPP unit (ACB GEC Alsthom, Nantes, France). Its cylindrical vessel has a diameter of 100 mm, is 300 mm tall, and has a net volume of 2.35 L. In this case, the equipment was filled with water that acted simultaneously both as the sample and as the pressure-transmitting fluid.
Chapter 3
Neural Networks: Their Role in High-Pressure Processing
20 External temperature + + + –
K–
1 s
Water
Integrator
Sum 1 –K Water
– + Sum 3 –
–K Heater
+
60
Thermostat Sum 2 Cooler n° 1
Temperature of the sample 1
On/off Cooler n° 2
0 On/off
Figure 3.6. Block diagram of a thermoregulation bath.
Before solving the model represented in Figure 3.7, it is necessary to input the thermophysical properties of the different components taking part in the HPP system as a function of pressure and temperature. However, currently, to find all those thermophysical properties is not easy. In the case of food, these properties could be approximated by using the methods described in Otero et al. (2010). In the case of the pressure-transmitting fluid, it could help to use data from Otero et al. (2002a) for water and data from Guignon et al. (2008) for water and for other fluid. The last task to be performed is to integrate the differential equations taking part in the model. For this purpose, the Euler or other suitable method can be chosen. The model is able to predict the evolution of temperature versus time in different points of the HPP system such as inside the HP vessel, at the entrance, at the exit of the surrounding coil, and inside the thermoregulation bath (Otero et al. 2002a).
51
Once a macroscopic model is working, contrasting a variety of its numerical results with the behavior of the corresponding experimental results from real high-pressure processes is required. Only after accurate results are obtained from both kinds of data can the collection of an important amount of results (using the macroscopic model with conditions similar to those previously checked) become simple. In relation to this, concerns regarding the approaches related to steady-state processes and/or with linear behavior for heat transfer that have been initially adopted to build the macroscopic model are always required. In fact, results from this modeling approach have been obtained in order to provide data for building NNs in HPP (Torrecilla et al. 2004, 2005, 2007c). Apart from that, a better description about what happens during HPP is achieved if not only pure heat transfer processes are considered but also more complex processes with energy, mass, and momentum interactions (Otero et al. 2007). Unfortunately, to improve the model described in Section 3.6 by accounting for all those complex processes is not easy at all.
3.7. Conclusions In the field of numerical modeling of chemical and food processing operations, two powerful tools, namely artificial NNs and macroscopic models, have been described in this chapter. NNs can be used for the prediction of important characteristics of a process without the need for assumptions in nonlinear mathematical relations between dependent and independent variables. The examples presented in this chapter show, for example, how composition of chemicals and foods upon processing and process parameters and variables (e.g., freezing temperature during HPP) can be reliably estimated. Besides, macroscopic models also appear to be an interesting tool: Although the creation of macroscopic models requires notable assumptions and simplifications, they have proven to be useful for the prediction of important process data in HPP of foods. A characteristic example is the determination of the
52 1/z
1/s
+ – ++
-K-
Mux
1/s
+ –
+ –
++
-K-
Steel
+
+
+
+
+ -K-
Exit temp. at the coil Entrance tubeambient heat flow +
+ –
-K-
+ -K- –
-K-
1/s
Thermost.
Thermor. bath
Compressor
-K-
100
Bath-amb. flow -K-
-K-
1 on/of 1/0
– +
+ –
Refrig. circuit Exit tube-ambient heat flow + -K- –
Heat flow through the wall insulators
Heat flow at the top
Heat flow at the bottom
Entrance tube in the surrounding coil
-K
– –
Steel-coil heat flow
-K-
Medium temp. in the coil
Entrance temp. at the coil
-K-
1/s
Steel-coil heat flow Water temp. in the Steel vessel temp.
Exit temp. at the coil
-K-
Temp. at the entrance and exit of the coil
1 – z Delay
MATLAB Function dT/dp
-K-
+ +
1/s
Figure 3.7. Extended model for the simulation of thermal exchanges in high-pressure equipment.
Init. pressure Delay
Pressure
Final pressure
Pressure
Steel-water heat flow
Steel-water heat flow
Target temp.
39
Bath temp.
Tamb Ambient temp.
Chapter 3
Neural Networks: Their Role in High-Pressure Processing
temperature profiles inside the HPP vessel for a specific set of process conditions. Macroscopic models allow the fast and reliable generation of the resulting process variables caused by changes in the process parameters, such as the initial temperature of the vessel or the boundary temperature of the system. The combination of the aforementioned tools opens a wide spectrum of applications that could be successfully deployed not only in the academia but more importantly for industrial applications as well.
Acknowledgments This work has been supported by the National Plan of Spanish I+D+I of the Ministry of Education and Science (MEC) through the projects AGL2007-63314/ALI, the CSD2007-00045 MALTA CONSOLIDER-INGENIO 2010, and the Madrid Community through the project S2009/PPQ-1551.
Notation Cp H h i j k Lr MPE MSE N n NN P q r T V w x y α λ
Specific heat capacity, J/kg/°C Height, m Surface heat transfer coefficient, Wm−2/°C Input layer Hidden layer Output layer Learning rate Mean prediction error Mean square error Number of output neurons Iteration of a cycle of the learning process Neural network Pressure Rate of heat transfer, W Radius, m Temperature, °C Specific volume, m3/kg Weight of neural networks Input value into neuron Output value of the neuron Thermal expansivity coefficient, °C−1 Thermal conductivity, Wm−1/°C
53
References Arbib MA. 2003. The Handbook of Brain Theory and Neural Networks, 2nd ed. Cambridge: The Massachusetts Institute of Technology. Boillereaux L, Cadet C, Le Bail A. 2003. Thermal properties estimation during thawing via real-time neural network learning. J Food Eng 57:17–23. Bridgman PW. 1912. Water, in the liquid and five solid forms, under pressure. Proceedings of the American Academy of Arts and Sciences, XLVIII(13):439–558. Chen CH. 1996. Fuzzy Logic and Neural Network Handbook. New York: McGraw-Hill. De Heij W, Van Schepdael L, Van Den Berg R, Bartels P. 2002. Increasing preservation efficiency and product quality through control of temperature distributions in high pressure applications. High Press Res 22(3-4):653–657. Demuth H, Beale M, Hagan M. 2005. MATLAB User ’s Guide, V 4.0: Neural Network Toolbox. Natick, MA: MathWorks Inc.. Fikiin KA. 1998. Ice content prediction methods during food freezing: A survey of the Eastern European Literature. J Food Eng 38:331–339. Fine TL. 1999. Feedforward Neural Network Methodology. New York: Springer-Verlag. Fonseca AM, Biscaya JL, Aires-de-Sousa J, Lobo AM. 2006. Geographical classification of crude oils by Kohonen selforganizing maps. Anal Chim Acta 556:374–382. Fuchigami M, Ogawa N, Teramoto A. 2002. Trehalose and hydrostatic pressure effects on the structure and sensory properties of frozen tofu (soybean curd). Innov Food Sci Emerg Technol 3:139–147. Guignon B, Otero L, Molina-García AD, Sanz PD. 2005. Liquid water-ice I phase diagrams under high pressure: Sodium chloride and sucrose models for food systems. Biotechnol Prog 21(2):439–445. Guignon B, Torrecilla JS, Otero L, Ramos A, Molina-García AD, Sanz PD. 2008. The initial freezing temperature of foods at high pressure. CRC Crit Rev Food Sci Nutr 48:328–340. Hopfield JJ. 1982. Neural networks and physical systems with emergent collective computational abilities. Proc Natl Acad Sci U S A 79:2554–2558. Hopfield JJ. 1984. Neural networks and physical systems with graded response have collective properties like those of two state neurons. Proc Natl Acad Sci U S A 81:3088– 3092. Huang Y, Kangas LJ, Rasco BA. 2007. Applications of Artificial Neural Networks (ANNs) in Food Science. CRC Crit Rev Food Sci Nutr 47:113–126. Kakaç S, Yener Y. 1985. Heat Conduction, 2nd ed. Berlin: Springer-Verlag. Kohonen T. 1987. Self-Organization and Associative Memory, 2nd ed. Berlin: Springer-Verlag. Le Bail A, Chevalier D, Mussa DM, Ghoul M. 2002. High pressure freezing and thawing of foods: A review. Int J Refrigeration 25:504–513.
54
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Masoum S, Bouveresse DJR, Vercauteren J, Jalali-Heravi M, Rutledge DN. 2006. Discrimination of wines based on 2D NMR spectra using learning vector quantization neural networks and partial least squares discriminant analysis. Anal Chim Acta 558:144–149. McCulloch WS, Pitts W. 1943. A logical calculus of the ideas immanent in nervous activity. Bull Math Biophys 5:115–133. Minsky ML, Papert S. 1969. Perceptrons: An Introduction to Computational Geometry. Cambridge, MA: MIT Press. Otero L, Sanz PD. 2000. High-pressure shift freezing. Part I: Amount of ice instantaneously formed in the process. Biotechnol Prog 16:1030–1036. Otero L, Sanz PD. 2003. Modelling heat transfer in high pressure food processing: A review. Innov Food Sci Emerg Technol 4:121–134. Otero L, Molina-García AD, Sanz PD. 2000. Thermal effect in foods during quasi-adiabatic pressure treatments. Innov Food Sci Emerg Technol 1:119–126. Otero L, Molina AD, Sanz PD. 2002a. Some interrelated thermophysical properties of liquid water and ice. I. A user-friendly modeling review for food high-pressure processing. CRC Crit Rev Food Sci Nutr 42(4):339–352. Otero L, Molina-García AD, Ramos AM, Sanz PD. 2002b. A model for real thermal control in high-pressure treatment of foods. Biotechnol Prog 18(4):904–908. Otero L, Ramos AM, de Elvira C, Sanz PD. 2007. A model to design high-pressure processes towards an uniform temperature distribution. J Food Eng 78(4):1463–1470. Otero L, Guignon B, Aparicio C, Sanz PD. 2010. Modeling thermophysical properties of food under high pressure. CRC Crit Rev Food Sci Nutr 50(4):344–368. Palancar MC, Aragon JM, Torrecilla JS. 1998. pH-control system based on artificial neural networks. Ind Eng Chem Res 37:2729–2740. Pham QT. 2006. Modelling heat and mass transfer in frozen foods: A review. Int J Refrigeration 29:876–888. Plumb AP, Rowe RC, York P, Brown M. 2005. Optimisation of the predictive ability of artificial neural network (ANN) models: A comparison of three ANN programs and four classes of training algorithms. Eur J Pharm Sci 25:395–405. Raju KS, Kumar DN, Duckstein L. 2006. Artificial neural networks and multicriterion analysis for sustainable irrigation planning. Comput Oper Res 33:1138–1153. Rumelhart DE, Hinton GE, Williams RJ. 1986. Learning representations by back-propagation errors. Nature 323:533–536. Sanz E, Vega C, Abascal JLF, MacDowell LG. 2004. Phase diagram of water from computer simulation. Phys Rev Lett 92(25 I):255701–255701. Schlüter O, Urrutia Benet G, Heinz V, Knorr D. 2004. Metastable states of water and ice during pressure-supported freezing of potato tissue. Biotechnol Prog 20:799–810. Shimizu T. 1992. High-pressure experimental apparatus with windows for optical measurements up to 700 MPa. High Press Biotechnol 224:525–527.
Si-Moussa C, Hanini S, Derriche R, Bouhedda M, Bouzidi A. 2008. Prediction of high-pressure vapor liquid equilibrium of six binary systems, carbon dioxide with six esters, using an artificial neural network model. Braz J Chem Eng 25(01): 183–199. Ting E, Balasubramaniam VM, Raghubeer E. 2002. Determining thermal effects in high-pressure processing. Food Technol 56(2):31–35. Torrecilla JS, Otero L, Sanz PD. 2004. A neural network approach for thermal/pressure food processing. J Food Eng 62:89–95. Torrecilla JS, Otero L, Sanz PD. 2005. Artificial neural networks: A promising tool to design and optimize high-pressure food processes. J Food Eng 69:299–306. Torrecilla JS, Fernández A, García J, Rodríguez F. 2007a. Determination of 1-ethyl-3-methylimidazolium ethylsulfate ionic liquid and toluene concentration in aqueous solutions by Artificial Neural Network/UV spectroscopy. Ind Eng Chem Res 46:3787–3793. Torrecilla JS, Mena ML, Yáñez-Sedeño P, García J. 2007b. Quantification of Phenolic Compounds in Olive Oil Mill Wastewater by Artificial Neural Network/Laccase Biosensor. J Agric Food Chem 55:7418–7426. Torrecilla JS, Otero L, Sanz PD. 2007c. Optimization of an artificial neural network for thermal/pressure food processing: Evaluation of training algorithms. Comput Electron Agric 56:101–110. Torrecilla JS, Mena ML, Yáñez-Sedeño P, García J. 2008a. A neural network approach based on gold-nanoparticle enzyme biosensor. J Chemometrics 22:46–53. Torrecilla JS, Fernández A, García J, Rodríguez F. 2008b. Design and optimisation of a filter based on Neural Networks. Application to reduce noise in experimental measurement by TGA of thermal degradation of 1-Ethyl-3-methylimidazolium ethylsulfate ionic liquid. Sens Actuators B Chem 133: 426–434. Torrecilla JS, Cámara M, Fernández-Ruiz V, Piera G, Caceres JO. 2008c. Solving the spectroscopy interference effects of βcarotene and lycopene by neural networks. J Agric Food Chem 56:6261–6266. Torrecilla JS, Rojo E, García J, Oliet M, Rodríguez F. 2009a. Determination of toluene, n-heptane, [emim][EtSO4], and [bmim][MeSO4] ionic liquids concentrations in quaternary mixtures by UV-vis spectroscopy. Ind Eng Chem Res 48:4998–5003. Torrecilla JS, Rojo E, Oliet M, Domínguez JC, Rodríguez F. 2009b. Self-organizing maps and learning vector quantization networks as tools to identify vegetable oils. J Agric Food Chem 57:2763–2769. Urrutia Benet G, Chapleau N, Lille M, Le Bail A, Autio K, Knorr D. 2006. Quality related aspects of high pressure low temperature processed whole potatoes. Innov Food Sci Emerg Technol 7:32–39. Urrutia-Benet G, Balogh T, Schneider J, Knorr D. 2007. Metastable phases during high-pressure—Low-temperature
Chapter 3
Neural Networks: Their Role in High-Pressure Processing
processing of potatoes and their impact on quality-related parameters. J Food Eng 78:375–389. Wagner W, Saul A, Pruss A. 1994. International equations for the pressure along the melting and along the sublimation curve of ordinary water substance. J Phys Chem Ref Data 23: 515–525.
55
Werbos P. 1974. Beyond regression—New tools for prediction and analysis in the behavioral sciences. PhD thesis, Harvard University. Zhu S, Ramaswamy HS, Le Bail A. 2005. Ice-crystal formation in gelatine gel during pressure shift versus conventional freezing. J Food Eng 66:69–76.
Chapter 4 Computational Fluid Dynamics Applied in High-Pressure Processing Scale-Up Cornelia Rauh and Antonio Delgado
4.1. Introduction The present contribution deals with the use of computational fluid dynamics (CFD) for simulating and scaling up high-pressure processes. Thus, it appears convenient to address briefly three different thematic blocks here. First, it is the goal of this contribution to discuss high-pressure processes to the level that provides an introductory understanding of their most relevant features. This allows the exclusion of such high-pressure fields in which similar problems with scaling up occur but are considered beyond the framework of the present scholarly piece. The second thematic block is dedicated to CFD. As completeness in the treatment of such a subject is neither aimed at nor achievable, only particular topics are elucidated here. Last but not least, the third thematic block is related to the necessity of including CFD in the investigation of high-pressure processes and its role in scaling up. The effect of high pressure on matters of different constitution and origin is currently the objective of very different investigations in different fields such as physics, chemistry, applied mathematics, biology, oceanography, astronomy, material sciences, technical fabrication, medicine, and biotechnology as well as food sciences and technology. Although the basic
effects of high pressure have a great deal in common, it appears convenient to focus the present contribution on biomatter, that is, on matter of biological origin such as food and biotechnological substances. In the addressed field, treatment with media pressurized up to several tens of MPa, that is, pressure near the critical point is performed in order to exploit exceptional physicochemical properties. Among them a substantial decrease in viscosity and a drastic increase in diffusion constant could be observed. In this context, surface energies drop and extraction of hardly soluble systems can be realized even on technical scale (Eckert et al. 1996; Higashi et al. 2001; Jaeger et al. 2002; Sarrade et al. 2003). Despite its high potential, this subject is considered out of the framework of the present chapter. Also, the research activities that took place in the field of marine biology, for example, under deep-sea conditions, (see e.g., Zobell and Morita 1957; Kato et al. 1998) are not considered here. Although high-pressure treatment of biomatter has drastically gained a high interest only in the last decades, the very first research activities in this field were reported as early as in the late nineteenth century. Hite (1899) could observe a reduction of microorganisms in highly pressurized milk. A few years later, the Nobel laureate Bridgman (1914)
Innovative Food Processing Technologies: Advances in Multiphysics Simulation, First Edition. Edited by Kai Knoerzer, Pablo Juliano, Peter Roupas, and Cornelis Versteeg. © 2011 by John Wiley & Sons, Ltd. and Institute of Food Technologists. Published by John Wiley & Sons, Ltd. ISBN: 978-0-813-81754-5
57
58
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
reported on the irreversible denaturation of albumen at a pressure level of 700 MPa. However, the revival of intensive research activities in food applications started in the past decades in Japan (Deuchi and Hayashi 1992; Fuchigami et al. 1997, 1998a, 1998b; Hayakawa et al. 1998; Yoshioka et al. 1999; Suzuki 2002, 2003). It has been substantially emphasized by the increasing interest in industrial production in which the peculiarity of high pressure of affecting both molecular and cellular processes is specifically used. In the present high-pressure treatment of food and biotechnological materials, high-pressure processing is considered as an emerging method with an extremely wide spectrum of possible applications. Basically, this is due to the fact that pressure is a fundamental thermodynamic quantity, comparable to temperature or chemical potential. In fact, the results of sufficiently applying high pressures to biomatter prove to be extremely manifold as pressure influences mechanisms and kinetics as well as structures and generates novel phenomena. This reveals, in turn, pressure as a “basic tool for research, specific structure creation and process design” (Knorr 1996). Knorr (1996) compares the high-pressure treatment of food and biosubstances even with the introduction of “a new dimension.” Most recently, Delgado et al. (2007) have shown that high-pressure processes depend on the “complete process trajectory,” which, in turn, must consider not only the temporal but also the spatial dimensions. Thus, high-pressure processes can only be treated and controlled adequately by considering the available initial (i.e., the initial activity of enzymes or viability of microorganisms) and boundary conditions (temperature regime, applied pressure profile, etc.) and the physicochemical interactions of all acting components (biomatter, high-pressure pumps). Thus, system theory (Delgado et al. 2007) must be applied that allows for considering (1) spatiotemporal effects in connection with (2) unavoidable natural variations in the material constitution and the biological activity of the pressurized biomatter and (3) complex geometry of the pressurizing system, treatment chamber, and, if available, distribution of packaged food units, and, last but not least, product
and process inhomogeneities. Such a system treatment requires obviously tools such as CFD, which enable managing spatiotemporal distributions and, therefore, local changes resulting in heterogeneities. CFD has achieved a high level of recognition in engineering, natural sciences, and even medicine. This is primarily a consequence of the cross-sectional character of fluid mechanics in various disciplines such as aerospace and microgravity (Dreyer et al. 1994; Delgado et al. 1996; Kowalczyk and Delgado 2007a), aerodynamics and aviation (Becker et al. 2002), automotives engineering (Al-Hamamre and Trimis 2009), transport techniques (Khier et al. 2000), process engineering (Raufeisen et al. 2008), production technologies (Epple et al. 2009; Rauh et al. 2009), material sciences (Frohnapfel et al. 2007), environmental sciences (Diez et al. 2007), astrophysics (Peltier 1989), as well as human and animal biology (Kowalczyk and Delgado 2007b; Becker et al. 2008, 2009). On the other hand, the employed CFD has experienced a drastic increase recently due to the development of new architectured super computers and novel mathematical algorithms that allow for the first time the calculation of constitutively and geometrically very complex systems. These conditions are particularly given in highpressure processes up to several hundreds of MPa with biomatter capable of flowing and, more crucially, showing pressure-induced phase transition. In contrast to the opinion prevailing in the former literature, Delgado et al. (2007) as well as Delgado and Hartmann (2003) have shown that high-pressure treatments act, at least under nonacademic conditions, instantaneously but not homogeneously. More crucial pressurization always generates a deformation of the biomatter, that is, high-pressure treatment always induces a forced field of movement. Thus, in the case of matter capable of flowing, this has to generate forced convection. Due to the fact that during compression mechanical energy is converted into thermal energy, the temperature of the biomatter is elevated (with the exception of the most academic case of isothermal compression). Hardly controllable thermal diffusion, for example, at the wall of the treatment chamber induces therefore natural convection in addition. Thus, high-pressure
Chapter 4
Computational Fluid Dynamics in High-Pressure Processing Scale-Up
processes expose thermofluiddynamical effects as a rule. The existence of convection phenomena has been ignored for a long period of time or even challenged in the literature. But, for the first time, Pehl and Delgado (1999) as well as Delgado and Hartmann (2003) and Delgado et al. (2007) have conclusively proven their existence experimentally, theoretically, and numerically. In addition, considerations of thermofluiddynamical phenomena and mechanisms in connection with molecular and cellular reactions as well as mass transport and phase transition are treated in the most recent literature (Yasuda and Mochizuki 1992; Sanz et al. 1997; Sanz and Otero 2000; LeBail et al. 2003; Luscher et al. 2004; Baars et al. 2007; Delgado et al. 2008a, 2008b). The appearance of transport phenomena in diffusive and convective fields makes CFD essential for making progress in understanding, simulating, controlling, and automating high-pressure processes. More than that CFD provides a suitable platform for investigating process homogeneity and scalability.
4.2. Thermofluiddynamic Phenomena under High-Pressure Conditions In general, CFD is based on mathematical balancing models that, for a given, fixed balance volume, express the temporal change of the quantity of interest such as mass, momentum, and energy due to (1) diffusive and convective transport through the surface of the balance volume and (2) generation within the volume. In addition, the constitutive equations as well as the initial and boundary conditions must be available for ensuring completeness of the mathematical model and, thus, its solvability. As a rule, balancing leads to a system of integral or differential equations that are solved classically by using numerical finite approaches such as finite differences, volumes, elements, or boundary elements (Ferziger and Peric 2002). However, when describing thermofluiddynamical phenomena and mechanisms under high pressure, the “state-of-the-art” proves to be not sufficient for formulating all balance equations required. This is the case particularly with regard to the constitution
59
of the biomatter and high-pressure-induced molecular and cellular reactions. Thus, advanced approaches that enable managing other sources of knowledge (Kilimann et al. 2006) must be implemented for completing the knowledge base. The present chapter focuses on classical CFD procedures. As a consequence of this, no considerations regarding hybrid methods are discussed here that enable managing further knowledge; these methods are the subject of intensive investigations in the present (Kilimann et al. 2006). However, for the sake of achieving better access to modeling and simulation by CFD, it appears convenient to discuss first some particular high-pressure-induced phenomena. Of course, this is done from the point of view of applying CFD for simulating high-pressure treatment.
4.2.1. Transport of Mass, Momentum, and Energy Literature reviews concerning this topic have been published by Hendrickx et al. (1998) and Otero and Sanz (2003) for particular aspects, and by Delgado et al. (2008b) in a more general sense. Mass, momentum, and energy can be assumed to be conservative quantities. Thus, their corresponding fields are determined by constitutive, state, and transport parameters. Additionally, the transport of mass, momentum, and energy is often strongly interrelated in flow fields. This is especially the case in high-pressure systems in which the peculiarity of high pressure for affecting both molecular and cellular processes is specifically used. Basically, the mechanical force acting during pressurization alters the molecular equilibrium. This may generate not only a modification of the molecular and cellular interactions but also an increase in the energy level (Heremans 1982; Denys et al. 1997, 2000b; Cheftel et al. 2000; Fachin et al. 2002; Doster and Friedrich 2004; Kowalczyk et al. 2004, 2005; Kowalczyk and Delgado 2007a; Kulisiewicz et al. 2007). In turn, this could lead to both a modification of the matter pressurized and an increase in temperature, if the transfer of energy from the pressure chamber to the surroundings is inhibited by, for example, the chamber walls. Thus, in the sense of system theory
60
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
(Delgado et al. 2007), the interaction of all components of the high-pressure system has an impact on the occurrence of thermofluiddynamical fields. This corresponds to a direct influence on product and process inhomogeneities, which have to occur almost always (Denys et al. 1997, 2000a; Sanz et al. 1997; Pehl and Delgado 1999; Otero et al. 2000; Pehl et al. 2000; Hartmann 2002; Hartmann and Delgado 2002; Hartmann et al. 2003; Otero and Sanz 2003; Kowalczyk et al. 2004). Here, exceptions are provided by the limiting case of a single, pure liquid component under isothermal and adiabatic conditions. However, the isothermal change of state requires a dissipative transfer of the complete pressurizing energy to the surroundings. But this can be performed only approximately by extreme slow compression due to the finite heat conductivity and the nonvanishing thermal capacity of the pressure chamber. Thus, isothermal pressurization would lead to an inapplicable long treatment time and to substantially reduced energy process efficiency. Furthermore, it is connected to the loss of the benefits wished in certain cases (e.g., in the inactivation of microorganisms) resulting from the synergetic action of the effect of pressure and temperature increase in general occurring during pressurization. Last but not least, nonvanishing thermal conductivity and finite thermal capacity of the pressurizing system inhibit additionally the strict occurrence of an adiabatic change and lead at the same time to the generation of temperature inhomogeneities. As shown by Delgado and Hartmann (2003), the existence of temperature gradients perpendicular to the direction of gravity represents a necessary and sufficient condition for the initiation of a flow in matter capable of flowing. As a consequence of this, process inhomogeneities with the corresponding transport of matter, momentum, and energy occur. Additionally, matter of biological origin consists, as a rule, of several components and phases with different physical and chemical behavior. This includes material heterogeneities that, in turn, exclude per se a homogeneous treatment (Delgado and Hartmann 2003). Furthermore, inhomogeneities induce timedependent equalization actions in the field that could substantially have different time and length scales
(Pehl and Delgado 1999; Pehl et al. 2000; Kowalczyk et al. 2004; Baars et al. 2007; Kowalczyk and Delgado 2007a, 2007c). As a consequence of this, the actual state of the processed biomatter depends on the whole “treatment history” and, thus, on the exchange of momentum, energy, and mass (Delgado et al. 2007). Therefore, any scaling up must aim at achieving an identical or, at least, a comparable treatment history. The high-pressure processes considered here are characterized by the flowability of the biomatter. Thus, in general, the latter property is given for a biomatter consisting of the liquid aggregate state. Hereby, the liquid component must be considered as compressible due to the high values of the pressure applied. This represents a crucial contrast to most other applications with condensed matter capable of flowing in which compressibility shows to be negligible. Thus, compressibility is considered in the literature as one of the most prominent properties of high-pressure processes; although it takes values substantially smaller than those of gases (Meschede 2006) often treated in CFD. Therefore, with respect to using CFD for simulating pressurized liquid biomatter, this represents well manageable requirements. Also, the pressure-induced changes of thermal conductivity and capacity reach only moderate values and, therefore, do not cause significant problems in the simulation. In contrast to this, high pressure may alter viscosity in a drastic way. Först (2002) has shown viscosity of edible oils and fats increasing up to four orders of magnitude. As, additionally, the pressure dependence of biomatter shows to be strongly nonlinear, complex interrelations between the mass, momentum, and energy transport must be expected (Delgado and Hartmann 2003). As an example, Song et al. (2009) have found pressure being able to alter basically the structure of turbulence and, as a result of this, the transport in the pressure chamber.
4.2.2. Influence of Pressure on Molecular and Cellular Reactions The reaction of biomatter to pressurization depends strongly on its components. It is well accepted in the
Chapter 4
Computational Fluid Dynamics in High-Pressure Processing Scale-Up
literature that macromolecular components such as proteins or enzymes could be altered or denaturized at sufficiently high-pressure level (Heremans 1982; Denys et al. 1997, 2000; Cheftel et al. 2000a; Fachin et al. 2002; Doster and Friedrich 2004; Kowalczyk et al. 2004, 2005; Kowalczyk and Delgado 2007a; Kulisiewicz et al. 2007). This provides a suitable basis for the specific creation of new structures (Tauscher 1995; Hinrichs 2000; Kieffer et al. 2007). In contrast to this, the mechanisms induced by pressure acting on low molecular weight compounds such as vitamins are generally reversible (Tauscher 1995; Baars et al. 2004). This allows for the preservation of the beneficial properties of foods during high-pressure treatment (Takahashi et al. 1993; Cheftel 1995; Tauscher 1995; Meyer et al. 2000; Heinz and Knorr 2002). Additionally, the physicochemical occurrences connected to a high-pressure exposition may strongly affect or even inactivate the biotic function of organisms (Ludwig et al. 1992; Heinz and Knorr 1996; Gaenzle et al. 2001; Kilimann et al. 2006). It is obvious that molecular as well as cellular reactions depend on the spatial distributions of the mass, momentum, and energy fields available in the pressurizing chamber. Furthermore, the time behavior is of particular interest. From the relationship of the characteristic time of the pressure propagation (which is connected to the sound velocity) and the characteristic time of the treatment (such as the hydrodynamic and thermal time as inner scales or the pressurizing and the pressure-holding time as process scales) the impact of the pressure on the molecular equilibrium can be considered instantaneous (Delgado and Hartmann 2003). Exceptions that prove this rule are very fast molecular or cellular reactions with time scales in the order of magnitude of the pressure propagation, but these have not been investigated particularly with respect to this issue yet. Realizing the relevance of spatiotemporal distributions is of crucial importance as the treatment history determines, for example, the level of preservation of biomatter achievable including microbiological safety, the quality of the product in question, as well as the processing energy required. Thus,
61
scaling up can be performed only adequately when the transport fields are known. This shows the inalienability of and the enormous potential made accessible by CFD. This compilation elucidates that discussing the approaches presented in the literature for modeling and simulating high-pressure treatments purely from the point of view of the specific treatment goals is somewhat tedious. This is especially due to the immense variety of the mechanisms, kinetics, structures, and phenomena possible that makes it difficult to find common classification attributes. However, in Delgado et al. (2008b), a generalized way of classification is proposed. It is based on the complexity and the level of simplification considered being appropriate for modeling and for reducing calculation costs to a reasonable extent. In contrast to this, in the next section the mathematical models proposed in the literature are discussed without going into details of possible simplifications.
4.3. Mathematical Modeling and Numerical Simulation of High-Pressure Processes The high-pressure treatment normally takes place in a so-called high-pressure autoclave. In many cases, tempering mechanisms are installed at the outer wall of the autoclave. The high-pressure processing itself consists of three steps: compression, pressure holding, and decompression. Thus, the use of balancing approaches requires equations suitable for describing these different phases (Hartmann et al. 2004; Kilimann et al. 2006; Rauh et al. 2009). However, most of the contributions in the literature deal with the effect of high pressure on a specific treatment step (Rademacher et al. 2002; Hinrichs and Rademacher 2005) or even the various steps are not differentiated explicitly but described by the thermodynamical conditions existing during the pressure holding time. However, in the literature balancing approaches that consider in general available spatiotemporal distribution of the physicochemical effects of high
62
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
pressure have been employed only recently (e.g., Denys et al. 2000a; Hartmann and Delgado 2002; Kilimann et al. 2006; Delgado et al. 2008b; Rauh et al. 2009). This is obviously due to large numerical power requirements as a consequence of the complexity of the resulting balance equations (see the following equations). But most crucial, it represents a result of assumptions in the literature that simplify modeling and simulation to a substantial extent but that are also questionable (Rauh et al. 2009).
4.3.1. Basic Balancing Equations and Thermophysical Properties In summary, it can be stated that any realistic model must enable the description of spatiotemporal instead of pure time-dependent effects as done within usual pure kinetic considerations. In this sense, modeling the effect of high pressure on pure, chemically and electromagnetically inert, and newtonian substances capable of flowing within a continuum model can be done by using the wellintroduced balances of thermofluiddynamics. This requires formulations of the conservation of mass, ∂ρ + ∇ ⋅ ( ρU ) = 0, ∂t momentum, ⎤ DU ⎡ ∂U =⎢ + (U ⋅ ∇ )U ⎥ Dt ⎣ ∂t ⎦ 1 1 1 1 1 = − ∇p + ∇ ⋅ ( μ∇U ) + Fg , ρ ρ Re 0 ρ Fr0
(4.1)
(4.2)
and energy (formulated for the temperature T ) DT α T Dp 1 1 = ΠT0 + ∇ ⋅ ( λ ∇T ) Dt cp ρ Dt cp ρ Re 0 Pr0 +
1 Ec 0 μ Φ, cp ρ Re 0
(4.3)
which are quoted in dimensionless notation here (Delgado et al. 2008b). In the sense of similarity analysis, this reduces not only the number of influence quantities but also delivers basic rules for scaling up.
Although the model Equations 4.1–4.3 are valid for the different pressure-generating systems employed, a piston system is considered. In this context, the initial dimensional chamber length L*0 and the piston velocity u0* represent obviously adequate length and velocity scales that lead to the characteristic process time τ c = L*0 / u0* for the pressurizing and depressurizing phase, in which the motion of the biomatter occurs mainly due to forced convection (Delgado and Hartmann 2003). In contrast to this, buoyancy, that is, natural convection, dominates the intermediate pressure-holding phase as shown experimentally by Pehl et al. (2000), theoretically by Delgado and Hartmann (2003), and numerically by Hartmann and Delgado (2002), Baars et al. (2007), and Rauh et al. (2009). However, for natural convection no characteristic velocity can be given a priori. Instead, the reference velocity * ubouy = g*α 0* ΔT * L*0 , which results from a balance of driving and hindering forces in the natural flow field, is often used in the literature (Spurk 2004). In this definition the dimensional parameters α 0* and ΔT * denote the isothermal expansion coefficient and a characteristic temperature difference driving the natural convection. The further state and transport parameters appearing in the model equations are obtained by self-relation. Thus, the density, thermal conductivity, thermal capacity, isothermal expansion coefficient, thermal diffusivity, as well as the dynamic viscosity are normalized by using the corresponding dimensional λ* quantities ρ0* , λ * , cp* , α * , a* = * * and μ * (as well ρ cp μ* as the kinematic viscosity ν * = * , of course) at ρ * * pressure p0 and T0 . Here, the normalization of the temperature has been performed by considering T0* as a further characteristic quantity of the thermal field. Additionally, the pressure in the momentum Equation 4.2 scales u*2 with the kinetic pressure ρ0* 0 . In contrast to this, 2 u*2 it scales with the total pressure p0* + ρ0* 0 ≈ ρ0* cp* 0T0* 2 in the energy Equation 4.3.
Chapter 4
Computational Fluid Dynamics in High-Pressure Processing Scale-Up
In the model Equations 4.1–4.3, the symbols Φ and Fg represent the dissipation due to friction and the gravitational force in dimensionless notation, respectively. In addition to the dimensionless simplexes obtained from the self-relation of the constitutive and kinematic parameters, the following dimensionless groups appear in the balance Equations 4.1–4.3:
ρ0*U 0* L*0 characterizes μ0* the ratio of convective and diffusive momentum; U *2 • the Froude number Fr0 = * 0 * balances the effect L0 g of gravity relative to that of convection; U 0*2 • the Eckert number Ec 0 = * * allows a statement cp 0T0 regarding the influence of flow-induced compressibility on dissipation; and μ0* cp* 0 ν * • the Prandtl number Pr0 = * = 0* expresses λ0 a0 the ratio of momentum and energy diffusion.
• the Reynolds number Re 0 =
The additional dimensionless group Π T0 = α 0*T0* appears in the energy equation and characterizes the increase of thermal energy due to the volumetric work that has to be applied for pressurization. Further details to similarity analysis are given, for example, by Stichlmair (1990). In order to examine the consequences of any spatiotemporal thermofluiddynamical distribution during the high-pressure processing onto the desired biotechnological conversion, model equations other than Equations 4.1–4.3 for as much as additional scalars than variables in question must be introduced. As a rule, the scalar variable represents the inactivation of a cellular or molecular system. In a general sense the additional variable is treated as a component with a given interaction with the dispersed phase. By nature, the implied interaction may correspond to physicochemical as well as cellular mechanisms. But, in any case, the molecular (index m) or cellular (index c) systems are transported by
63
mechanisms induced by forced and natural convection as mentioned above. Furthermore, due to their small length scales ( lm* ≈ 10 −9 m for proteins and lc* ≈ 10 −6 m for microorganisms), they have to be expected to be in mechanical and thermal equilibrium. It can be shown that there is a local equilibrium, that is, the availability of a “congruent thermofluiddynamical state” of the continuous phase and the dispersed molecular or cellular systems at any time during high-pressure treatment with respect to given spatial coordinates. Fortunately, this facilitates modeling substantially as the effects of high pressure on molecular or cellular reactions can be abstracted mathematically as those on a general scalar quantity φ *. φ* In dimensionless formulation for φ = * the φ0 corresponding transport model writes as ∂φ 1 + ∇ ⎡⎣φU ⎤⎦ = ∇ ⋅ ( Dϕ ∇φ ) + Da 0 Qϕ . (4.4) ∂t Re 0 Sc 0 The left side of this model equation coincides completely with that of the mass conservation. Thus, for a molecular biocomponent, Equation 4.4 expresses simply high-pressure-induced conversion. The latter is connected to the diffusion as well as the generation or reduction of the biocomponent in question. Diffusion effects are due to the possible existence of field inhomogeneities of the scalar in question φ . Thus, the parameter Dϕ in the first term on the right side of the model (Eq. 4.4) represents a diffusion constant of the molecular or cellular process in question. The order of magnitude of diffusion depends obviously on the reciprocal value of the product of the Reynolds number Re 0 and the Schmidt number ν* Sc 0 = 0* . The latter gives an estimation of the ratio D0 of diffusive transport of the momentum and of the scalar in question φ . A further effect related to the (positive or negative) generation of φ is given by the (dimensionless) source term Da 0 Qϕ in the model Equation 4.4, in which the strength of the source Qϕ is regulated by the value of the Damköhler-number Da 0 . The latter describes the relation of a convective time scale and the time scale of the molecular reaction.
64
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
For example, for an n-order reaction with a concentration c = φ , the source strength is Qϕ = − kc n and L* k * c* n−1 the Damköhler number is Da 0 = 0 0 * 0 . u0 In agreement to the discussion of local congruent thermofluiddynamical states of the dispersed molecules and the continuous phase, one of the basic ideas of the model Equation 4.4 consists of considering that the molecule in question reacts as far as the required values of the thermodynamic variables pressure and temperature are available. However, it is important to understand that introducing an additive source term in the model (Eq. 4.4) postulates local homogeneity in addition to local mechanical and thermal equilibrium between the dispersed system and the continuous phase being valid. More concretely, it means that reactions in the specifically considered point of the biomatter and those in a spatial neighboring domain run in dependency of the same local thermofluiddynamical state. In other words, there is no interference such as restrictions or inhibitions between reactions occurring concurrently at places of small spatial distance.
4.3.2. Thermophysical Properties and Limitations of Balancing Equations For the use of the explained differential equations it has to be taken into account that the thermophysical properties (viscosity, thermal conductivity, thermal capacity, and density) of the treated material are pressure- and temperature-dependent. Therefore, formulations have to be given to determine this behavior. In the case of pure water, relations for the density and thermal capacity exist, for example, from Saul and Wagner (1989), and for the viscosity and thermal conductivity from the International Association for the Properties of Water and Steam (IAPWS). The validity of these models is restricted to a region from the melting lineup to 1,273 K and 25,000 MPa for the density and the thermal capacity and to temperatures between 273 and 423 K at a pressure of up to 500 MPa as well as a temperature range from 273 to 398 K up to 400 MPa for the viscosity and the thermal conductivity, respectively.
For more complex biomatter, there is a lack of precise data and corresponding models describing these thermophysical properties (compare also Otero and Sanz 2003). Torrecilla et al. (2004, 2005) overcome this by using artificial neural networks for prediction of process parameters. Some examples for examination of properties of food materials are given by Denys and Hendrickx (1999) and Denys et al. (2000b) for thermal conductivity, density, and thermal expansion coefficient of apple sauce and tomato paste under pressure as well as for thermal capacity under atmospheric conditions. Eder and Delgado (2002) and Eder et al. (2003) determine the behavior of the density of water, ethanol, glycerine mixtures, sucrose solutions, and water and sunflower oil with dissolved carbon dioxide. Research on the pressure dependency of the viscosity of sucrose solutions, whey protein solutions, and sunflower oil is done by Först (2002) and of heat conductivity of water, corn oil, sucrose solutions, and other liquids by Bridgman (1949), Lawson et al. (1959), and Werner et al. (2003). The lack of thermophysical data represents a severe restriction for the use of balancing models. More than that, constitutive complex biomatter can show complex mechanical, that is, rheological behavior. Not only pure viscous but also elastic and time-dependent phenomena can occur. This may affect drastically the stability and convergence of CFD procedures. For avoiding any misinterpretation in the following discussions, for any modeling and simulation approach presented the availability of suitable data for the biomatter in question is assumed to be given; no further comments on the model limitations are discussed.
4.4. Prediction of Process Impact and Control of High-Pressure Treatment Control of treatment represents one of the most important current research goals for high-pressure processes (Delgado et al. 2007). With respect to industrial application, scaling up is closely related to this task. First indications of adequate rules for scaling up can be directly found by considering the similarity
Chapter 4
Computational Fluid Dynamics in High-Pressure Processing Scale-Up
Table 4.1. Characteristic order of magnitude of dimensionless groups in balancing equations. Dimensionless groups Ec Re Fr Pr ΠD = Ec/Re ΠT
Order of magnitude 10−8 102 103 10 10−10 10−2
groups appearing in the basic Equations 4.1–4.3. Table 4.1 shows the typical order of magnitude of dimensionless parameters. Summarizing the values presented it can be concluded that (1) dissipative effects as expressed by Ec can be neglected, but in contrast to this (2) forced convection (influence of Re), natural convection (Fr), compression work (ΠT)as well as viscous diffusion (Pr) contribute significantly to mass, momentum, and energy transfer in the chamber. However, this means neither equality of the contributions to the transport processes in the pressurized chamber nor similarity of the transport fields. This can be directly deduced, for example, from a comparison of the momentum and energy Equations 4.2 and 4.3. Achieving similarity imposes the very restrictive conditions to be fulfilled: (1) unidirectional flow, (2) negligible pressure differences, (3) vanishing effects of gravity, (4) constant material parameters, and (5) a Prandtl number close to unity. Similar requirements can be derived when comparing the biochemical balance Equation 4.4 with the momentum or energy balance. Thus, under practical conditions strict similarity of the different fields can hardly be achieved. In turn, this increases the difficulties connected to the transfer of results from the laboratory to the production scale. In fact, when scaling up all dimensionless quantities appearing in the basic Equations 4.1–4.4, they must reach the same value in the laboratory and production scale. However, it must be taken into consideration that the scaling rules for the different similarity groups can deviate basically and, thus, deliver even contradictory results. For illustrating this statement the simple case of two systems
65
with the same biomatter as well as initial and boundary conditions should be discussed briefly. In this case only geometrical similarity is kept. But, while the forced convection scales with Re ∝ L*0 , the 1 natural convection depends on Fr ∝ * . Now, L0 these are obviously contradictory rules for scaling up. As a consequence of this it must be stated that strict similarity cannot be achieved when scaling up. Instead, only partial or asymptotic similarity (i.e., for Fr → ∞ or Re → ∞) appears to be realizable. As a consequence of this it can be concluded that the most appropriate way to achieve process homogeneity in scaled-up systems consists of a design that makes use of CFD in order to analyze a priori the transport phenomena during the high-pressure application. In this sense CFD represents also a powerful tool for realizing adaptive control strategies as basically required (Delgado et al. 2007). For elucidating this statement, results obtained by using CFD are presented and discussed. These are based on the work of Hartmann (2002), Rauh et al. (2009), and Kilimann et al. (2006), who proved by experimental validation the ability of the present numerical code to describe thermofluiddynamics and biochemical reactions under high pressure, respectively. For numerical solution of the partial differential equations that model the mass, momentum, and energy transport, discretization of the derivatives with respect to time and space was conducted accordingly to the second-order backward Euler scheme and the highresolution scheme. The discretized equations were solved by applying the finite volume method. For grid generation and for solution of differential equations, the commercial software ANSYS ICEM CFD 10.0 and CFX 10.0 (Canonsburg, PA), respectively, were applied. Additionally, FORTRAN codes developed by the present authors with about 25,000 statements were implemented. These codes describe the piston movement for pressure generation, pressureand temperature-dependent properties of water and some model foods (e.g. sucrose solutions), and the source terms (i.e., inactivation kinetics) of the transport equations. The three-dimensional computational domain is meshed with a structured grid shown in Figure 4.1.
66
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
4.4.1. Different Phases of High-Pressure Treatment
In the vicinity of all walls the grid is refined. This can be seen in Figure 4.1B at the lateral surface. The whole mesh consists of 2.5 · 106 elements. As the bottom of the computational domain is moving, all calculations take place on a moving mesh.
In addition to the reasoning presented in the preceding section it must be taken into consideration that scaling up can only be achieved when similarity of the “treatment history” is given in the different phases of the high-pressure treatment. As mentioned above, in the literature only a minor number of publications are devoted to the study of the complete high-pressure treatment. Pehl and Delgado (1999) showed experimentally for the first time that pressurization, pressure holding, and depressurization phases lead to strongly deviating thermofluiddynamic effects. This is in agreement with the numerical results of Rauh (2009), which are depicted graphically in Figure 4.2. The simulation shows a vertical chamber pressurized by a piston. From this diagram the existence of five different phases can be concluded. In the initial time period during compression (marked by 1 in the diagram) and in the decompression phase (5) forced convection dominates. The period (2) is characterized by the development of velocity and temperature
Figure 4.1. Computational mesh: (A) perspective front view; (B) top view.
Tad 1.00 0.95 0.89 0.84 0.79 0.74 0.68 0.63 0.58 0.53 0.47 0.42 0.37 0.32 0.26 0.21 0.16 0.11 0.05 0.00
u/(L/tprocess)
T
18 16 14 12 10 8 6 4 2 0
W=0 W = 0.25 W = 0.5
0
0.2
0.4
0.6
0.8
1
t/tprocess
Figure 4.2. Development of temperature field and vertical velocity near the cylindrical wall at mid-height of the autoclave during a high-pressure process with aqueous sucrose solution containing W = 0, 0.25, 0.5 kg/kg sucrose (1, 5: forced convection; 2: development of thermal/ hydrodynamic layer; 3: fully developed thermal/hydrodynamic layer; 4: horizontal temperature stratification). See color insert.
Chapter 4
Computational Fluid Dynamics in High-Pressure Processing Scale-Up
67
boundary layers in free convection as the biomatter adheres to the wall of the chamber and, in general, exchanges thermal energy through the wall. Consequently field gradients must appear. As the inner momentum and thermal time reaches values being substantially smaller than the process time (see e.g., Pehl and Delgado 1999; Baars et al. 2007), the generation of the layers can be considered as finished in phase (3). In phase (4) a decrease of the natural convection due to the buildup of a horizontal density-driven temperature stratification in the center of the vessel occurs. From these flow features it can also be concluded that scaling up to a production scale can only be realized in part. For example, it is well known that the thickness of boundary layers increases nonlinearly along the wall. Thus, any change of the chamber length results in boundary extensions that do not scale.
Although CFD can manage inactivation of microorganisms in a similar way, only molecular, that is, biochemical reactions, are considered in the following for convenience. In Rauh et al. (2009), the uniformity of enzymatic conversion processes was examined. This was carried out by evaluation of pressure- and temperature-induced inactivation of the enzymes polyphenoloxidase (PPO), lipoxygenase (LOX), α-amylase (BSA), and β-glucanase (BGLU). The study of p-T diagrams for these reactions (not shown) indicates that at different pressure and temperature levels, covered by high-pressure processes, the sensitivity of the reactions varies significantly. As proposed by Baars et al. (2007), the inactivation rate k can be divided into two parts describing the pressure sensitivity (kP) and temperature sensitivity (α) of the reaction:
4.4.2. Examples for CFD-Based Investigations of the Impact of Process Inhomogeneities on Molecular and Cellular Systems
with
The previous sections have elucidated the missing strict scalability of mass, momentum, and energy transport in high-pressure processes and, thus, of process inhomogeneities. Consequently, identical “treatment histories” cannot be achieved in principle. This must be taken into consideration in any scale-up reasoning, but has been ignored in the literature yet. As a consequence of this, transferring data from the laboratory to the production scale has to lead to severe discrepancies and confusions as can be frequently found in the literature. This is particularly the case when considering the impact of transport phenomena, that is, of process inhomogeneities on biochemical and cellular reactions. In general, homogeneity can be assumed to be given in a lab frame, but hardly under production conditions. Thus, scaling-up process goals are subjected to severe restrictions that have been studied systematically only in single cases (Otero and Sanz 2003; Delgado et al. 2008b). However, systematic studies of transport processes cannot be performed without using CFD.
k ( p, T ) = kP (1 + α ) ⋅ (6 )
kP ( p, T0 ) = k ( p0 , T0 ) + ∫
α ( p, T ) =
p p0
( ∂k / ∂p )T dp
( ∂k / ∂T ) p (T − T0 ) kP
Table 4.2 summarizes the dimensionless values of kP* = kP t process and α for the inactivation kinetics of PPO, LOX, BSA, and BGLU. At a process pressure of 700 MPa, the temperature dependence of the inactivation reactions is quantified by the variable α in Table 4.2. For determination of the thermal sensitivity, that is, the dependence of (bio)chemical reactions on temperature variations, both kP* and α have to be considered. Values of α much greater than 1 indicate that small changes in temperature have great consequences for the rate of the inactivation reaction. However, if kP* is much smaller or larger than 1, this has a small effect on the overall process impact as the reaction is too slow or fast, respectively, to cause differences in conversion during the process time. Values of α close to −1 lead in conjunction with kP* >> 1 to remaining heterogeneities. From this, it can be concluded that for processes starting at T0 = 293 and 323 K the inactivation of LOX is the one most likely
68
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Table 4.2. Pressure and temperature sensitivity of inactivation reactions (PPO, LOX, BSA, BGLU) expressed by kP* = kP ⋅ tprocess and α, respectively (p = 700 MPa, T0 = 293, and 323 K, T = Tad). α (p, T)
kP* ( p, T0 ) T0 = 293 K PPO LOX BSA BGLU
<10−3 7.76 0.06 0.06
T0 = 323 K
T0 = 293 K
T0 = 323 K
0.02 0.35 0.33 0.09
12.80 −0.95 2.23 −0.26
13.53 34.25 2.31 129.61
(a) A* 1.00 0.95 0.89 0.84 0.79 0.74 0.68 0.63 0.58 0.53 0.47 0.42 0.37 0.32 0.26 0.21 0.16 0.11 0.05 0.00
PPO
LOX
to show nonuniformity due to thermal heterogeneities. The inactivation of PPO, LOX, and BGLU is expected to be more likely during a process starting at T0 = 323 than 293 K. The behavior of the inactivation of BSA is similar in a process starting at 293 K to the one starting at 323 K. For processes starting at 323 K (a) and 293 K (b), Figure 4.3 illustrates the distribution of the remaining activity of the different enzymes at the end of the holding time. Case (a) shows significant heterogeneities of PPO, LOX, BSA, and BGLU distributions and
BSA
BGLU
(b) BSA BGLU PPO LOX A* 1.00 0.95 0.89 0.84 0.79 0.74 0.68 0.63 0.58 0.53 0.47 0.42 0.37 0.32 0.26 0.21 0.16 0.11 0.05 0.00 Figure 4.3. Dimensionless enzyme activity A* (enzymes suspended in water) at the end of pressure-holding time of a highpressure process (autoclave 2.3 L; pressure ramp 400 MPa/s; pressure-holding time 120 s at 700 MPa; initial temperature of process [a] 323 K and [b] 293 K). PPO, polyphenoloxidase; LOX, lipoxygenase; BSA, bacillus subtilis α-amylase; BGLU, β-glucanase (Rauh et al. 2009). See color insert.
Chapter 4
Computational Fluid Dynamics in High-Pressure Processing Scale-Up
69
Dimensionless temperature increase
1.0 Particle 1 Particle 2
0.8
0.6
0.4
0.2
0.0
–0.2
0.0
0.2
0.4
0.6
0.8
1.0
Dimensionless pressure application time tt* Figure 4.4. Different treatment histories of two enzymes due to nonuniform temperature distributions and convective and diffusive transport phenomena during the process. Left: particle tracks of two different enzymes (Particle 1, Particle 2) during a high-pressure process; right: temperatures faced by the two enzymes (Particle 1, Particle 2) at different locations and times. See color insert.
process (b) of LOX and BSA. In both processes, convective transport of the liquid plays an important role. Thus, convective transport of the enzymes influences the treatment history of the enzymes during the process. This leads for all investigated enzymes to differences in topology of the activity fields in comparison with those of the temperature fields. Model Equation 4.4 in its completeness is currently the subject of investigation (Rauh et al. 2009). Thus, in the literature (Delgado et al. 2008b) only simplified forms for (a) pure time-dependent molecular and cellular reactions and (b) the additional effect of convection as indicated by ∇ ⎡⎣φU ⎤⎦ can be found, but no diffusion in accordance to the term 1 ∇ ⋅ ( Dϕ ∇φ ) are treated. Re 0 Sc 0 As a further example of the results reported in the literature by Kitsubun (2006), Figure 4.4 shows the results of simulation of the spatial trajectories of two different enzymes during a high-pressure process (left). The location for different times of the
enzymes is followed from their entrance into the vessel up to the end of the process. During the process the moving enzymes pass different temperature levels corresponding to the temperature distribution in the pressurized chamber. The right part of Figure 4.4 plots the temperature that each of the enzyme (Particle 1, Particle 2) is facing at its present location during the whole process. Therefore, both the spatial trajectories and the temperature distribution determine the “treatment history” of the enzymes in question.
4.5. Conclusions and Outlook This chapter elucidates the urgent necessity of considering high-pressure treatment as a process generated by a system with strong interrelated components (Delgado et al. 2007). This is particularly the case when aiming at process homogeneity and scaling up. The latter corresponds to the requirement of realizing similar “treatment history” in the laboratory and production scale.
70
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
From the results obtained it must be stated that strict similarity cannot be achieved under practical conditions. Only asymptotic similarity appears to be performable. Using CFD represents a unique possibility for considering mass, momentum, and energy transport as well as the impact of these quantities on molecular and cellular system along the process trajectory available in the treatment chamber. Yet, the use of CFD for a complete simulation of transport processes covering all stages of the highpressure process has taken place only in single cases. Additionally, CFD suffers from the restrictions imposed by missing physicochemical material data. For overcoming this situation, in the future the design and employment of approaches other than balancing is expected. Cognitive methods (Torrecilla et al. 2004; Kilimann et al. 2006) (Chapter 3) provide the most suitable platform for adaptive strategies as required in general for biomatter due to its high natural variance (Delgado et al. 2007). Kilimann et al. (2006) used methods of multivariate statistical analysis to analyze experimental data of inactivation of Lactococcus lactis toward correlations between variables. With this knowledge they built a fuzzy logic-based model to predict lethal and sublethal injury of the microorganisms in dependence of pressure, temperature, and co-solutes. Additionally, the application of hybrid methods is expected to increase dramatically. This is due to the enormous potential connected to them. Figure 4.5 illustrates this at results obtained from a hybrid that combines CFD with the Verhulst-Perl model for the inactivation of L. lactis (Kilimann et al. 2006). Distributions of stress-resistant cell counts relative to the initial one ( log ( N N 0 ) ) of L. lactis showafter treatment for 4 minutes at 500 MPa baroprotective effects of 1.5 M sucrose (middle) and 4 M NaCl (right) in milk buffer compared with milk buffer without any additives (left). In the cases with baroprotectives the inactivation is lower. This is even true although the temperature is higher in these processes (316 K instead of 304 K) and inactivation increases with raising temperature. To minimize thermally induced spatial concentration heterogeneities in the considered high-pressure process, four possibilities arise (Baars et al. 2007).
log (N/N0) 0 –1 –2 –3 –4 –5 –6 –7 –8
x* y*
Figure 4.5. Distributions of stress-resistant cell counts N ( log ) of Lactococcus lactis (4 minutes at 500 MPa). Left: N0 treatment in milk buffer (304 K); middle: milk buffer with 1.5 M sucrose (316 K); right: milk buffer with 4 M NaCl (316 K).
1. Homogenization of the chamber content by convection (mixing). 2. Homogeneous temperature field in the chamber due to heat conduction. 3. Volume of the thermal boundary layer should be small with respect to the chamber volume. Furthermore, convective transport of fluid from the wall into the center of the pressure chamber should be prevented. 4. Avoidance of thermal gradients by adjusting the wall temperature to the temperature present under adiabatic conditions. Chapter 5 provides other alternatives to control temperature inhomogeneities during high pressure processing.
Acknowledgment Parts of this work has been carried out with financial support from the Deutsche Forschungsgemeinschaft (DFG), Bundesministerium für Bildung und Forschung, and Commission of the European Communities, Framework 6, Priority 5 “Food Quality and Safety,” Integrated Project NovelQ FP6-CT-2006-015710.
Chapter 4
Computational Fluid Dynamics in High-Pressure Processing Scale-Up
Notation
Fr0
Froude number
Fr0 =
Pr0
Prandtl number
Pr0 =
Π T0
Dimensionless group
Re 0
Reynolds number
Sc 0
Schmidt number
Latin Variables a c cp Dϕ D Dt Fg g k L p Qϕ t T ΔT u U X Y
Thermal diffusivity Concentration Thermal capacity Diffusion constant Total derivative Gravitational force Gravity constant Reaction rate Length Pressure Source Time Temperature Characteristic temperature difference Norm of velocity vector Velocity Coordinate Coordinate
Greek Variables α ∇ ∂ ∂t φ Φ λ μ ν ρ τ ener τc
Isothermal expansion coefficient Gradient operator Partial derivative Scalar Dissipation Thermal conductivity Dynamic viscosity Kinematic viscosity Density Inner thermal time scale Characteristic process time
Dimensionless Numbers Da 0
Damköhler number
Ec 0
Eckert number
L*0 k0* c0* n−1 u0* U *2 Ec 0 = * 0 * cp 0T0
Da 0 =
71
U 0*2 L*0 g*
μ0* cp* 0 ν 0* = * λ0* a0 Π T0 = α 0*T0* ρ*U * L* Re 0 = 0 *0 0 μ0 ν 0* Sc 0 = * Dϕ 0
Indices * 0 buoy
Dimensional parameter Reference parameter Buoyancy
References Al-Hamamre Z, Trimis D. 2009. Investigation of the intermediate oxidation regime of Diesel fuel. Combustion Flame 156(9): 1791–1798. Baars A, Pereyra N, Delgado A, Margosch D, Ehrmann M, Vogel R, Czerny M, Schieberle P, Meußdoerffer F. 2004. High Hydrostatic pressure—An energy saving technology for preservation of food. Proc. ICEF9, Montpellier, 7–11 March 2004, 159–164. Baars A, Rauh C, Delgado A. 2007. High pressure rheology and the impact on process homogeneity. High Press Res 27(1): 73–79. Becker S, Lienhart H, Durst A. 2002. Flow around threedimensional obstacles in boundary layers. J Wind Eng Ind Aerodynamics 90(4–5):265–279. Becker S, Kniesburges S, Müller S, Delgado A, Kaltenbacher B. 2008. Experimentelle Modellbildung der Fluid-StrukturAkustik-Wechselwirkung bei der menschlichen Stimmgebung. Chem Ing Tech 80(9):1284–1285. Becker S, Kniesburges S, Müller S, Delgado A, Link G, Kaltenbacher M, Döllinger M. 2009. Flow-structure-acoustic interaction in a human voice model. J Acoust Soc Am 125(3):1351–1361. Bridgman PW. 1914. The coagulation of albumen by pressure. J Biol Chem 19:511–512. Bridgman PW. 1949. The Physics of High Pressure, 2nd ed. London: G. Bell & Sons. Cheftel JC. 1995. Review: High-pressure, microbial inactivation and food preservation. Food Sci Technol Int 1:75–90. Cheftel JC, Lévy J, Dumay E. 2000. Pressure-assisted freezing and thawing: Principles and potential applications. Food Rev Int 16(4):453–483.
72
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Delgado A, Hartmann C. 2003. Pressure treatment of food: Instantaneous but not homogeneous effect. In: R Winter, ed., Proceedings of the 2nd International Conference on High Pressure Bioscience and Biotechnolgy. Advances in High Pressure Bioscience and Biotechnolgy, 459–464. Dortmund, 16–19 September 2002. Berlin: Springer. Delgado A, Nirschl H, Becker T. 1996. First use of cognitive algorithms in investigations under compensated gravity. Microgravity Sci Technol 9(3):185–192. Delgado A, Baars A, Kowalczyk W, Benning R, Kitsubun P. 2007. Towards system theory based adaptive strategies for high pressure bioprocesses. High Press Res 27(1):7–16. Delgado A, Rauh C, Benning R. 2008a. Thermodynamisches Modell zum Fest/flüssig-Phasenübergang von Substanzen hohen molaren Volumens. Chem Ing Tech 80(8):1185–1192. Delgado A, Rauh C, Kowalczyk W, Baars A. 2008b. Review of modeling and simulation of high pressure treatment of materials of biological origin. Trends Food Sci Technol 19:329–336. Denys S, Hendrickx ME. 1999. Measurement of the thermal conductivity of foods at high pressure. J Food Sci 64(4):709–713. Denys S, Van Loey AN, Hendrickx ME, Tobback PP. 1997. Modeling heat transfer during high-pressure freezing and thawing. Biotechnol Prog 13:416–423. Denys S, Van Loey AM, Hendrickx ME. 2000a. A modeling approach for evaluating process uniformity during batch high hydro-static pressure processing: Combination of a numerical heat transfer model and enzyme inactivation kinetics. Innov Food Sci Emerg Technol 1:5–19. Denys S, Van Loey AM, Hendrickx ME. 2000b. Modeling conductive heat transfer during high pressure thawing processes: Determination of latent heat as a function of pressure. Biotechnol Prog 16:447–455. Deuchi T, Hayashi R. 1992. High pressure treatments at sub-zero temperature: Application to preservation, rapid freezing and rapid thawing of foods. In: C Balny, R Hayashi, K Hermans, P Masson, eds., High Pressure and Biotechnology, 353–355. London: John Libbey and Co. Ltd. Diez L, Zima BE, Kowalczyk W, Delgado A. 2007. Investigation of multiphase flow in sequencing batch reactor (SBR) by means of hybrid methods. Chem Eng Sci 62(6):1803–1813. Doster W, Friedrich J. 2004. Pressure–temperature phase diagrams of proteins. In: J Buchner, T Kiefhaber, eds., Protein Folding Handbook. Part I, 99–126. Weinheim: Wiley-VCH Verlag GmbH & Co. KGaA. Dreyer M, Delgado A, Rath HJ. 1994. Capillary rise of liquid between parallel plates under microgravity. J Colloid Interface Sci 163(1):158–168. Eckert CA, Knutson BL, Debenedetti PG. 1996. Supercritical fluids as solvents for chemical and material processing. Nature 383:313–318. Eder C, Delgado A. 2002. Interferometrische Dichtemessung an flüssigen Lebensmitteln. In: A Leder, M Brede, B Ruck, D Dopheide, et al., eds, Lasermethoden in der Strömungsmesstechnik, 10, Fachtagung, Rostock, 10–12 September 2002 (Beitrag 56). Rostock: Universitätsdruckerei.
Eder C, Delgado A, Goldbach M, Eggers R. 2003. Interferometrische in-situ Densitometrie fluider hochkomprimierter Lebensmittel. In: D Dopheide, H Müller, V Strunck, B Ruck, A Leder, eds, Lasermethoden in der Strömungsmesstechnik, 11, Fachtagung, Braunschweig, 9–11 September 2003 (Beitrag 28). Braunschweig: Universitätsdruckerei. Epple P, Karic B, Ilic C, Becker S, Durst F, Delgado A. 2009. Design of radial impellers: A combined extended analytical and numerical method. Proc Inst Mech Eng C J Mech Eng Sci 223(4):901–917. Fachin D, Van Loey A, Indrawati I, Ludikhuyze L, Hendrickx M. 2002. Thermal and high-pressure inactivation of tomato polygalacturonase: A kinetic study. J Food Sci 67:1610–1615. Ferziger JH, Peric M. 2002. Computational Methods for Fluid Dynamics, 3rd ed. Berlin: Springer. Först P. 2002. In-situ Untersuchungen der Viskosität fluider, komprimierter Lebensmittel-Modellsysteme. Fortschritt-Berichte VDI. Reihe 3. Nr. 725. Düsseldorf: VDI-Verlag. Frohnapfel B, Jovanovic J, Delgado A. 2007. Experimental investigation turbulent drag reduction by surface-embedded grooves. J Fluid Mech 590:107–116. Fuchigami M, Kato N, Teramoto A. 1997. High pressure freezing effects on textural quality of carrots. J Food Sci 62:804–807. Fuchigami M, Kato N, Teramoto A. 1998a. High-pressurefreezing effects on textural quality of Chinese cabbage. J Food Sci 63:122–125. Fuchigami M, Teramoto A, Ogawa N. 1998b. Structural and textural quality of kinu-tofu frozen-thenthawed at highpressure. J Food Sci 63(6):1054–1057. Gaenzle MG, Ulmer HM, Vogel RF. 2001. High pressure inactivation of Lactobacillus plantarum in a model beer system. J Food Sci 66:1174–1181. Hartmann C. 2002. Numerical simulation of thermodynamic and fluid-dynamic processes during the high-pressure treatment of liquid food systems. Innov Food Sci Emerg Technol 3:11–18. Hartmann C, Delgado A. 2002. Numerical simulation of convective and diffusive transport effects on a high-pressure-induced inactivation process. Biotechnol Bioeng 79:94–104. Hayakawa K, Ueno Y, Kawamura S, Kato T, Hayashi R. 1998. Microorganism inactivation using high-pressure generation in sealed vessels under sub-zero temperature. Appl Microbiol Biotechnol 50:415–418. Hartmann C, Delgado A, Szymczyk J. 2003. Convective and diffusive transport effects in a high pressure induced inactivation process of packed food. J Food Eng 59:33–44. Hartmann C, Schuhholz J-P, Kitsubun P, Chapleau N, Le Bail A, Delgado A. 2004. Experimental and numerical analysis of the thermofluiddynamics in a high-pressure autoclave. Innov Food Sci Emerg Technol 5:399–411. Heinz V, Knorr D. 1996. High pressure inactivation kinetics of bacillus subtilis cells by a three state model considering distributed resistance mechanisms. Food Biotechnol 10:149–161. Heinz V, Knorr D. 2002. Effects of high pressure on spores. In: ME Hendrickx, D Knorr, eds., Ultra High Pressure Treatments of Foods, 77–114. New York: Kluwer Academic/ Plenum Publishers.
Chapter 4
Computational Fluid Dynamics in High-Pressure Processing Scale-Up
Hendrickx M, Ludikhuyze L, Van den Broeck I, Weemaes C. 1998. Effects of high pressure on enzymes related to food quality. Trends Food Sci Technol 9:197–203. Heremans K. 1982. High pressure effects on proteins and other biomolecules. Ann Rev Biophys Bioeng 11:1–21. Higashi H, Iwai Y, Arai Y. 2001. Solubilities and diffusion coefficients of high boiling compounds in supercritical carbon dioxide. Chem Eng Sci 56:3027–3044. Hinrichs J. 2000. Ultrahochdruckbehandlung von Lebensmitteln mit Schwerpunkt Milch und Milchprodukte-Phänomene, Kinetik und Methodik. Fortschritt-Berichte VDI, Reihe 3, Nr. 656. Düsseldorf: VDI-Verlag. Hinrichs J, Rademacher B. 2005. Kinetics of combined thermal and pressure-induced whey protein denaturation in bovine skim milk. Int Dairy J 15:315–323. Hite BH. 1899. The effect of pressure in the presentation of milk. West Virginia Agricultural Experiment Station, Morgantown. Bulletin 58:15–35. Jaeger PT, Eggers R, Baumgartl H. 2002. Interfacial properties of high viscous liquids in a supercritical carbon dioxide atmosphere. J Supercritical Fluids 24:203–217. Kato C, Li L, Nogi Y, Nakamura Y, Tamaoka J, Horikoshi K. 1998. Extremely barophilic bacteria isolated from the mariana trench, challenger deep, at a depth of 11,000 meters. Appl Environ Microbiol 64(4):1510–1513. Khier W, Breuer M, Durst F. 2000. Flow structure around trains under side wind conditions: A numerical study. Comput Fluids 29(2):179–195. Kieffer R, Schurer F, Köhler P, Wieser H. 2007. Effect of hydrostatic pressure and temperature on the chemical and functional properties of wheat gluten: Studies on gluten, gliadin and glutenin. J Cereal Sci 45(3):285–292. Kilimann KV, Kitsubun P, Chapleau N, Le Bail A, Delgado A, Gänzle MG, Hartmann C. 2006. Experimental and numerical study of heterogeneous pressure-temperature-induced lethal and sublethal injury of lactococcus lactis in a medium scale high-pressure autoclave. Biotechnol Bioeng 94(4):655–666. Kitsubun P. 2006. Numerical Investigation of Thermofluiddynamical Heterogeneities during High Pressure Treatment of Biotechnological Substances. Dissertation, TU Munich. Knorr D. 1996. Advantages, opportunities and challenges of high hydrostatic pressure application to food systems. In: R Hayashi, C Balny, eds., Proceedings of the International Conference on High Pressure Bioscience and Biotechnology, High Pressure Bioscience and Biotechnology, 279–287. Kyoto: Elsevier. Kowalczyk W, Delgado A. 2007a. Numerical simulation of phase change at high hydrostatic pressure under variable-gravity environment. Numer Heat Transfer Part A 51:735–751. Kowalczyk W, Delgado A. 2007b. Simulation of fluid flow in a channel induced by three types of fin-like motion. J Bionic Eng 4(3):165–176. Kowalczyk W, Delgado A. 2007c. On convection phenomena during high pressure treatment of liquid media. High Press Res 27(1):85–92.
73
Kowalczyk W, Hartmann C, Delgado A. 2004. Modeling and numerical simulation of convection driven high pressure induced phase changes. Int J Heat Mass Transfer 47(5): 1079–1089. Kowalczyk W, Hartmann C, Luscher C, Pohl M, Delgado A, Knorr D. 2005. Determination of thermophysical properties of foods under high hydrostatic pressure in combined experimental and theoretical approach. Innov Food Sci Emerg Technol 6(3):318–326. Kulisiewicz L, Baars A, Delgado A. 2007. Effect of high hydrostatic pressure on structure of gelatine gels. Bull Pol Acad Sci Tech Sci 55:239–244. Lawson AW, Lowell R, Jain AL. 1959. Thermal conductivity of water at high pressures. J Chem Phys 30:643–647. LeBail A, Boillereaux L, Davenel A, Hayert M, Lucas T, Monteau JY. 2003. Phase Transition in foods: Effect of pressure and methods to assess or control phase transition. Innov Food Sci Emerg Technol 4(1):15–24. Ludwig H, Bieler C, Hallbauer K, Scigalla W. 1992. Inactivation of microorganisms by hydrostatic pressure. In: C Balny, R Hayashi, K Hermans, P Masson, eds., High Pressure and Biotechnology, 25–32. London: John Libbey and Co. Ltd. Luscher C, Balasa A, Fröhling A, Ananta E, Knorr D. 2004. Effect of high-pressure-induced ice I-to-ice III phase transitions on inactivation of listeria innocua in frozen suspension. Appl Environ Microbiol 70(7):4021–4029. Meschede D. 2006. Gerthsen Physik, 23rd ed. Berlin: Springer. Meyer RS, Cooper KL, Knorr D, Lelieveld HLM. 2000. Highpressure sterilization of foods. Food Technol 54(11):67–72. Otero L, Sanz PD. 2003. Modeling heat transfer in high pressure food processing: A review. Innov Food Sci Emerg Technol 4:121–134. Otero L, Molina-García AD, Sanz PD. 2000. Thermal effect in foods during quasi-adiabatic pressure treatments. Innov Food Sci Emerg Technol 1:119–126. Pehl M, Delgado A. 1999. An in-situ technique to visualize temperature and velocity fields in liquid biotechnical substances at high pressure. In: H Ludwig, ed., Advances in High Pressure Bioscience and Biotechnology, 519–522. Heidelberg: Springer. Pehl M, Werner F, Delgado A. 2000. First visualization of temperature fields in liquids at high pressure. Exp Fluids 29:302–304. Peltier WR. 1989. Mantle Convection, Plate Tectonics and Global Dynamics. The Fluid Mechanics of Astrophysics and Geophysics. Montreux, Switzerland: Gordon and Breach Science Publishers. Rademacher B, Werner F, Pehl M. 2002. Effect of the pressurizing ramp on the inactivation of Listeria innocua considering thermodynamic processes. Innov Food Sci Emerg Technol 3:19–24. Raufeisen A, Breuer M, Botsch T, Delgado A. 2008. DNS of rotating buoyancy- and surface tension-driven flow. Int J Heat Mass Transfer 51:6219–6234. Rauh C. 2009. Modellierung und Simulation von Kurzzeit-UltraHochdruckprozessen. Fortschritt-Berichte VDI. Reihe 3. Nr. 901. Düsseldorf: VDI-Verlag.
74
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Rauh C, Baars A, Delgado A. 2009. Uniformity of enzyme inactivation in a short time high pressure process. J Food Eng 91:154–163. Sanz PD, Otero L. 2000. High-pressure freezing. Part 2. Modeling of freezing times for a finite cylindrical model. Biotechnol Prog 16:1037–1043. Sanz PD, Otero L, de Elvira C, Carrasco JA. 1997. Freezing process in high-pressure domains. Int J Refrigeration 20(5):301–307. Sarrade S, Guizard C, Rios GM. 2003. New applications of supercritical fluids and supercritical fluids processes in separation. Sep Purif Technol 32:57–63. Saul A, Wagner W. 1989. A fundamental equation for water covering the range from the melting line to 1,273 K at pressures up to 25,000 MPa. J Phys Chem Ref Data 18:1537–1564. Song K, Han Y, Al-Salaymeh A, Jovanovic J, Rauh C, Delgado A. 2009. In-situ investigation of turbulent fluid flow under high pressure conditions by means of Laser Doppler Anemometry and numerical simulation. In: A Delgado, C Rauh, H Lienhart, B Ruck, A Leder, D Dopheide, eds., 17. Fachtagung Lasermethoden in der Strömungsmesstechnik, Beitrag 45. Erlangen: GALA e.V., pp. 1–9. Spurk JH. 2004. Strömungslehre, Einführung in die Theorie der Strömungen. 5. Auflage, Berlin: Springer-Verlag. Stichlmair J. 1990. Kennzahlen und Ähnlichkeitsgesetze im Ingenieurwesen. Essen: Altos-Verlag Doris Stichlmair. Suzuki A. 2002. High pressure-processed foods in Japan and the world. In: R Hayashi, ed., Trends in High Pressure Bioscience and Biotechnology, 365–374. Amsterdam: Elsevier SC. Suzuki A. 2003. Current development of high pressure processed foods in Japan. IFT Annual Meeting, Chicago, 34–37.
Takahashi Y, Ohta H, Yonei H, Ifuku Y. 1993. Microbicidal effect of hydrostatic pressure on satsuma mandarin juice. Int J Food Sci Technol 28:95–102. Tauscher B. 1995. Review Pasteurization of food by hydrostatic high pressure: Chemical aspects. Z Lebensm Unters Forsch 200:3–13. Torrecilla JS, Otero L, Sanz PD. 2004. A neural network approach for thermal/pressure food processing. J Food Eng 62:89–95. Torrecilla JS, Otero L, Sanz PD. 2005. Artificial neural networks: A promising tool to design and optimize high-pressure food processes. J Food Eng 69:299–306. Werner M, Baars A, Delgado A. 2003. Bestimmung der Wärmeleitfähigkeit niedrigviskoser Lebensmittel unter Hochdruck mittels Hitzdrahtmethode. In: JP Baselt, G Gerlach, eds., 6. Dresdner Sensor-Symposium—Sensoren für zukünftige Hochtechnologien und Neuentwicklungen für die Verfahrenstechnik. Dresden: Universitätsverlag w.e.b., Band 20 (37/40). Yasuda A, Mochizuki K. 1992. The behavior of triglycerides under high pressure: The high pressure can stably crystallize cocoa butter in chocolate. High Press Biotechnol 224:255–259. Yoshioka K, Yamada A, Maki T, Yoshimoto C, Yamamato T. 1999. Application of high pressurisation to fish meat: the ultrastructural changes and nucleotide in frozen carp muscle under high pressure thawing. In: H Ludwig, ed., Advances in High Pressure Bioscience and Biotechnology, 501–504. Heidelberg: Springer. Zobell CE, Morita RY. 1957. Barophilic bacteria in some deep sea sediments. J Bactseriol 73(4):563–568.
Chapter 5 Computational Fluid Dynamics Applied in High-Pressure High-Temperature Processes: Spore Inactivation Distribution and Process Optimization Pablo Juliano, Kai Knoerzer, and Cornelis Versteeg
5.1. Introduction High-pressure high-temperature (HPHT) processing, also known as pressure-assisted thermal processing (PATP) or pressure-assisted thermal sterilization (PATS), is a novel emerging preservation method for the development of shelf-stable low-acid food products. HPHT involves combining pressures of 600 to 800 MPa with moderate initial chamber temperatures of 60 to 90°C. To achieve sterilization conditions, it takes advantage of the compression heating developed in the product and pressure-transmitting fluid, as well as the high pressure, to eliminate spore-forming bacteria (Matser et al. 2004; Margosch 2005; Barbosa-Cánovas and Juliano 2007). For instance, pressurization temperatures of 90 to 116°C combined with pressures of 500 to 700 MPa have been used to inactivate a number of strains of Clostridium botulinum spores (Farkas and Hoover 2000; Margosch et al. 2004). Other researchers showed that certain bacterial endospores (Clostridium sporogenes, Bacillus stearothermophilus, Bacillus licheniformis, Bacillus cereus, and Bacillus subtilis) in selected matrices like phosphate buffer, beef, vegetable cream, and tomato puree (Gola et al. 1996; Raso et al. 1998; Rovere et al. 1998; Meyer et al. 2000; Balasubramanian and Balasubramaniam
2003; Krebbers et al. 2003) can be eliminated after short-time exposure to temperatures and pressures above 100°C and 700 MPa, respectively. In February 2009, the U.S. Food and Drug Administration accepted a petition for the commercial production of a PATS-processed mashed potato-based product. This is the first process of this kind that has been filed and accepted (in a 35-L high-pressure sterilization vessel). Several HPHT combinations have been proposed for spore inactivation (de Heij et al. 2003; Leadley 2005; Barbosa-Cánovas and Juliano 2007), among which, the application of pressures greater than 600 MPa with short holding times (5 minutes or less) seems to be an appropriate balance between economical processing for industrial purposes and food safety. Shorter processing times would increase productivity and equipment lifetime, and reduce maintenance costs. Furthermore, a shorter thermal pressure process would result in a product with increased quality retention, making the process potentially more convenient than conventional incontainer sterilization (i.e., canning). This would particularly be the case for obtaining high-quality foods in large containers. In fact, in several HPHT studies, the process has been shown to produce foods with higher nutrients, color, and flavor along
Innovative Food Processing Technologies: Advances in Multiphysics Simulation, First Edition. Edited by Kai Knoerzer, Pablo Juliano, Peter Roupas, and Cornelis Versteeg. © 2011 by John Wiley & Sons, Ltd. and Institute of Food Technologists. Published by John Wiley & Sons, Ltd. ISBN: 978-0-813-81754-5
75
76
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
with other improved sensory attributes (Krebbers et al. 2002; Matser et al. 2004; Juliano et al. 2006a, 2006b, 2007; Barbosa-Cánovas and Juliano 2007). Thermal processing of foods requires the evaluation of the temperature and flow distributions involved at both the equipment and product level to assess the process performance. This information from HPHT processes can be utilized to predict the safety level achieved (i.e., the extent of C. botulinum inactivation), the product shelf stability (i.e., inactivation of spoilage organisms and enzymes), and the anticipated product quality (i.e., “cook” level and nutrition). Heat and mass transfer coupled with fluid dynamic models can greatly assist in evaluating the process performance through temperature and flow prediction. Computational fluid dynamic (CFD) models can be developed and applied to determine how a number of variables in the HPHT process affect heat generation and transfer and, therefore, temperature evolution throughout the vessel (Juliano et al. 2008b). CFD allows thermal and fluid dynamic models to be coupled to inactivation or degradation kinetic models and provide a two-dimensional (2D) or three-dimensional (3D) prediction of the safety and quality of all treated packages. A visual indication of the process performance can be given, showing vessel zones that may not be used as they do not reach the target temperatures or required inactivation, or result in undesirable overprocessing and quality degradation. Furthermore, the models can be utilized to improve process and equipment design. For example, compression heat retained in the vessel can be maximized by determining the optimum thickness of internal product carrier walls. The performance of the process at different scales, from small laboratory-scale vessels to industrialsize scales (i.e., 300–600 L capacity vessels) can also be compared. Once CFD models are validated against measured temperature data, output distributions from these models can assist regulatory authorities to approve the commercial use of the process. To achieve sterilization during pressurization, all treated food must at least reach the target compression temperature for a certain time during pressureholding time. To achieve this goal, a number of
variables must be controlled from the start. This chapter will provide an overview of the application of CFD models to predict uniformity of temperature and achieved sterility in HPHT systems.
5.2. Description of an HPHT Processing System 5.2.1. Vessel Components and Requirements A high-pressure system designed for sterilization conditions must be able to achieve high pressures of and above 600 MPa and chamber temperatures of at least 90°C. This can be accomplished by building a pressure chamber of appropriate materials and designing a high-pressure pumping system with fast pressure come-up. Today, sterilization systems range from laboratory scale (0.02–1.5 L), pilot scale (2–50 L), to industrial scale (150 L). Existing types of equipment have varied configurations (Balasubramaniam et al. 2004) that offer different levels of compression heat retention and efficiency. A typical (batch) HPHT machine system, applicable to all temperatures, consists of (1) a thick cylindrical steel vessel (often wire wound) with two end closures, (2) a means of restraining end closures, (3) a low-pressure pump, (4) an intensifier for system compression, using liquid from the lowpressure pump to generate high-pressure process fluid, and (5) necessary system controls and instrumentation (Farkas and Hoover 2000). Additionally, a preheating system with fittings for a package carrier and a post-process package cooling system are required. Stainless steel is preferred in the design of high-pressure chambers so that filtered (potable) water can be used as the compression fluid (Farkas and Hoover 2000). Other system components include the compression fluid, a product carrier basket, and the food to be processed (packed in flexible or semirigid containers). For HPHT treatment, the typical fluids used in pressure vessels include water, water with propylene-glycol, edible oils, and water/edible oil emulsions (Meyer et al. 2000). Oils assist in pump lubrication and provide additional compressionheating assistance. For commercial food processing
Computational Fluid Dynamics in High-Pressure High-Temperature Processes
purposes, the use of potable water is the most recommended compression medium for maintaining the cleanliness of product packages (Farkas and Hoover 2000). Packaging used for high-pressure treated foods, from institutional size to individual pouches, must accommodate more than a 12% reduction in volume, and be able to return to its original volume, without loss of seal integrity and barrier properties (Farkas and Hoover 2000; Caner et al. 2004). Until now, identification of suitable packages that can survive pressure sterilization with the combined highpressure and high-temperature conditions, that is, that retain seal and overall integrity, as well as adequate barrier properties against oxygen and water vapor, remains a challenge. Packaging materials tested at HPHT conditions were reviewed elsewhere (Koutchma et al. 2009; Juliano et al. 2010) The processed foods may differ in composition and, therefore, differ in their mechanical and thermophysical properties such as viscosity, density (porosity, tortuosity), compressibility, specific heat, and thermal expansivity, affecting compression
P1
5.2.2. The HPHT Process and Its Processing Variables The HPHT process consists of (1) preheating food packages in a carrier outside the vessel, (2) transferring the preheated carrier into the vessel and equilibrating up to an initial temperature, (3) pressurizing and holding at a target pressure, (4) releasing pressure, (5) removing carrier from vessel, and (6) cooling down products in the carrier and removing the products. Therefore, the temperature history inside an HPHT-processed food is determined by six main process time intervals (Juliano 2006; BarbosaCánovas and Juliano 2007; Figure 5.1): (1) product preheating to a target temperature Th, (2) product
P2
Temperature (°C)
Tp1
Th
Tp2
Ts Tf
Tc T0 0.1 MPa Equilibration t0
Preheating
th
ts
tp1
Decompression Holding
77
heating and heat transfer during processing. A common problem is the headspace initially contained in the pouches or the air released and water vapor developed as a result of preheating. For this reason, and to avoid degradative reactions during shelf storage, deaeration and a minimum headspace are recommended.
Pressure (MPa)
Chapter 5
tp2
tf
Cooling
Come-up
Figure 5.1. Typical temperature profile of a pressure-assisted thermal process.
Time tc
78
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
equilibration to initial temperature Ts, (3) product temperature increase to Tp1 due to compression heating, (4) product cooling down to Tp2 due to heat removal through the chamber, (5) product temperature decrease to Tf during decompression, and (6) product cooling to Tc. The critical process variables can be divided into preheating and HPHT process variables. Preheating variables at least include the temperature (heating fluid and product) and heating time, whereas HPHT variables include pressure (level, compression rate, and decompression rate), temperature (chamber, fluid filling the vessel, incoming pressure fluid, carrier, and product) and time. The temperature of the cooling fluid and product after processing as well as cooling time also needs to be taken into account. Factors affecting these variables during preheating, equilibration, pressure come-up, pressure holding, decompression, and cooling are summarized in detail by Juliano et al. (2008b). The selected preheating method can affect initial temperature distribution within and between individual packages and potentially provide a nonuniform microbial inactivation after HPHT. Water baths, steam, steam injection in water, or dielectric heating have been suggested as preheating alternatives (Juliano et al. 2006b). Faster preheating methods provide less uniformity, and thus require a longer time for equilibration to achieve temperature uniformity. 5.2.2.1. Compression Heating and Heat Losses Fluids like air and water as well as food packages undergo compression heating when pressurized above room temperature (Ting et al. 2002). A rise between 20 and 40°C has been observed in foods and packaging materials during high-pressure treatment, depending on the product initial temperature and food material. In fact, the compression-heating rate varies according to the composition of the food, in some cases similar to that of water at different pressure-temperature combinations (Ting et al. 2002; Balasubramanian and Balasubramaniam 2003). Few researchers have reported data on compression heating rates for food products at HPHT conditions. Compression heating of water is depen-
dent on the initial temperature (Ts) and has been reported as 3.0, 4.0, 4.6, and 5.3°C/100 MPa at initial temperatures, 20, 60, 75, and 90°C, respectively (Farkas and Hoover 2000; Balasubramaniam et al. 2004). Figure 5.2 shows the almost linear increase in temperature due to compression in (1) water, (2) orange juice, and (3) a glycol-water mixture (compression-heating fluid) up to 90°C and 600 MPa (Ardia et al. 2004; Knoerzer et al. 2010b). On the other hand, compression heating of steel is almost zero maintaining the core of the vessel wall near the initial temperature (Ting et al. 2002; de Heij et al. 2003). Therefore, without insulation, or internal heating in the steel walls, a thermal gradient is developed during pressurization and holding times (Denys et al. 2000b; Otero and Sanz 2003), leading to heat loss toward the chamber wall and subsequent cooling down of the fluid/sample system. Figure 5.1 shows a typical temperature profile during HPHT treatment, indicating the cooling down experienced in the holding process. Loss of heat is reflected in the difference between initial and final temperature during holding time (Tp2 < Tp1), and temperature at the beginning and end of the pressurization-depressurization period (Tf < Ts). In this case, “cold spots” may be located close to the vessel wall as a result of heat flow from the pressureheated product and pressure fluid next to the vessel wall. Moreover, during compression a certain amount of liquid (which may be preheated to an insufficient extent) enters the vessel (about 17% of the vessel volume, depending on the pressure increase). For improved insulation, that is, to prevent heat loss through the steel wall, a material with low thermal conductivity (less than 1 W/m/K) could be used as part of the pressure vessel design (de Heij et al. 2003; Van Schepdael et al. 2003), for example, as an internal liner. Another alternative is to use a polymeric carrier in which products are preheated to the initial temperature and then carried into the vessel. Vessel materials suggested for this application are polyoxymethylene (POM), polyetheretherketone (PEEK), polytetrafluoroethylene (PTFE), polypropylene (PP), or ultrahigh-molecular-weight polyethylene (UHMWPE). Knoerzer et al. (2010c) measured temperature of selected polymers during
Chapter 5
Computational Fluid Dynamics in High-Pressure High-Temperature Processes
160
Exper.
120
Theor.
Temperature (°C)
Temperature (°C)
100
80
60
40
120 100 80 60 40 20
20
0 0
Orange juice
Predicted Experimental
140
79
0
100
200
300
400
500
600
0
100
700
200
300
400
500
600
Pressure (MPa) (b) Orange juice
Pressure (MPa) (a) Water
140
420 from c-dependent kC P, T measurements
400
120 100 Temperature/°C
Temperature/K
380 360 340 320 300
80 60 40 20
280 260
Water Propylene-Glycol HDPE PP PTFE
0
100
200
300 400 500 Pressure/MPa
600
700
(c) Compression fluid (water glycol mixture)
0
0
100
200
300 400 500 Pressure (MPa)
600
700
(d) Polymers
Figure 5.2. Experimental and predicted compression heating curves of (a) distilled water; (b) orange juice; (c) water glycol mixture; and (d) insulating polymers and fluids (adapted from Ardia et al. 2004; Knoerzer et al. 2010b; Knoerzer et al. 2010c).
pressurization up to 90°C and 750 MPa and demonstrated that PP and Polyethylene (PE) have higher compression heating than water within the whole range (Figure 5.2d), whereas PTFE has higher compression heating up to 500 MPa. The authors did not
report a linear compression heating rate value of the polymers due to the logarithmic nature of curves, as opposed to the near linearity observed in fluids at elevated temperature (Figure 5.2a–c). Other authors have reported a compression heating of 4.5°C/100 MPa
80
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
on PP; however, the conditions were not clearly reported (Schauwecker et al. 2002). In order to maintain temperature, some HPHT installations can use an internal cylindrical heater or “furnace” located inside the chamber near the vessel wall. The furnace then surrounds the preheated polymeric liner for carrying the food packages. The furnace temperature is set higher than target initial temperature to prevent potential heat loss through the carrier into the vessel walls.
5.3. Developing a CFD Model for an HPHT System
The increase in temperature due to pressurization depends on the change of the expansion coefficient αp, density ρ (kg/m3), and specific heat capacity Cp of both the food and liquid during compression, as summarized in Equation 5.1. The thermodynamic derivation of the compression heating equation is covered in earlier literature (Ardia et al. 2004; Knoerzer et al. 2007; Juliano et al. 2008b). (5.1)
In a high-pressure system (insulated or not), heat can be diffused throughout the vessel boundaries. Then, the balance in Equation 5.2 can be expressed using terms for unsteady-state heat conduction during the pressure come-up step by using Fourier ’s law of heat diffusion, with heat generation term Q (Davies et al. 1999; Datta 2001). ∂ ⋅ ( k∇T ) + Q ( ρC pT ) = ∇ Compression ∂t Fourier’s Law Rate of accumulation
of unsteady heat conduction
∂P ∂t
(5.2)
heating
where k is the overall thermal conductivity of the fluid/food system inside the chamber. In this case, convective currents within the pressurizing fluid are assumed negligible and are not included in this balance. Based on Equation 5.1, Q represents the compression heating rate term expressed as:
(5.3)
where Q > 0 at ∀ t > ts (pressure come-up step) Q = 0 at ∀ t, tp1 < t < tp2 (pressure-holding step) Q < 0 at ∀ t, tp2 < t < tf (pressure-release step) Hence, Equation 5.2 also applies to the representation of all high-pressure processing steps. Thermal properties in the energy balance shown in Equation 5.2 can be rearranged so that the thermal diffusivity γ is part of the unsteady heat conduction term: ∂T Tα p ∂P = + γ ∇ 2T ∂t ρC p ∂t
5.3.1. Compression Heating Integrated in the Heat Transfer Balance
dT Tα p = . dP ρC p
Q = Tα p
(5.4)
The thermal diffusivity is directly proportional to the thermal conductivity at a given density and specific heat, that is,
γ =
k ρ ⋅Cp
(5.5)
In conventional heat transfer calculations, thermal conductivity is generally assumed to be independent of temperature (Holdsworth 1997). However, it is questionable whether or not this assumption can be made for some thermal properties in food materials and other polymeric materials, as their dependency on temperature and pressure is unknown.
5.3.2. Fundamental Equations of Fluid Motion The thermo- and fluid-dynamic behavior of the pressure medium influences temperature distribution and is described by conservation equations of mass, momentum, and energy (Hartmann et al. 2003). These equations account for the convection currents inside the vessel and are expressed as follows: • Mass conservation or equation of continuity (Chen 2006): ∂ρ + ∇ ⋅ ( ρV ) = 0 ∂t
(5.6)
Chapter 5
Computational Fluid Dynamics in High-Pressure High-Temperature Processes
81
where V is the velocity vector. This equation assumes that the fluid is initially at rest. Density increases with increasing pressure; therefore the first term in Equation 5.4 becomes nonzero. Since the left side must be equal to zero, the fluid velocity V must adopt nonzero values at pressure increments, thus enforcing a fluid motion. • Energy conservation (Chen 2006): ∂ ( ρC pT ) ∂P + ∇ ⋅ ( ρVC pT ) = + ∇ ⋅ ( k∇T ) (5.7) ∂t ∂t • Momentum conservation or Navier-Stokes Equation of Motion (Chen 2006): ⎤ ⎡ ∂V ρ⎢ + (V ⋅∇ ) V ⎥ = −∇P + ∇ ⋅ (η ⋅∇V ) + ρg (5.8) ⎣ ∂t ⎦ where η represents the viscosity of the compressed fluid and g represents the gravity constant. These partial differential equations are solved simultaneously, or as referred to in the literature, “coupled” by using CFD software (Knoerzer et al. 2007; Juliano et al. 2008b). These equations can also be coupled with other differential equations representing inactivation or degradation kinetics, and turbulence.
5.3.3. Boundary Conditions and Possible Assumptions The complete computational domain is defined by the sample, medium, carrier, and pressure vessel setup (also called subdomains) forming the highpressure system (e.g., Figure 5.3). The initial conditions of a system can be defined in its subdomains. Provided the system is initially at thermal equilibrium (i.e., uniform temperature distribution), the heat retention during pressure holding is limited by the sample’s mass, thermal diffusivity, and heat transfer coefficient at the sample boundary. Boundary conditions represent the thermal and/or flow behavior at the system’s external or internal boundaries. These options can be determined when constructing the model in CFD software packages. The most commonly applied boundary conditions in HPHT modeling are the symmetry boundary,
Steel wall boundary
Carrier
Water subdomains
Pressure water inlet Figure 5.3. Computational domain of a rotation-symmetric high-pressure vessel including a carrier for CFD modeling (adapted from Knoerzer et al. 2007).
inflow velocity boundary, the pressure boundary, and boundaries between the different subdomains: • The symmetry boundary is defined for an axissymmetric model system, also called pseudo 3D model, and requires less computational time than a 3D model. This is mainly possible by assuming the compression fluid enters from the geometrical center of the bottom part of the vessel (Figure 5.3). (This assumption is not valid for horizontal vessels since convective motion due to gravity is not axis-symmetric; therefore a full 3D model is required.) • The inflow velocity boundary applies to indirect pressure systems, that is, systems using an external high-pressure intensifier pump, where the inlet
82
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
tube allows the entrance of pressure fluid from the pump. • The pressure boundary is a condition including an expression for the pressure increase during compression and a constant pressure for the holding time is required. For decompression, the release of pressure fluid through the outlet can be imposed by a normal flow pressure condition. • Other boundary conditions include the heat transfer between the liquid and the solid subdomains (i.e., compression fluid, food, packages, and carrier and steel vessel walls). Continuity of heat flux at the vessel wall can be assumed between all fluid-solid and solid-solid boundaries. If laminar flow conditions exist, the fluid velocity at the chamber walls can be assumed zero due to fluid adhesion to the walls (no slip condition). Equations for these boundary conditions are detailed elsewhere (Juliano et al. 2008b; Knoerzer et al. 2010a). Other boundary conditions have been applied to specific models, such as the use of time-dependent vessel walls (due to heat transferred into the steel mass) (Hartmann et al. 2004) and the description of boundaries for turbulent flow conditions inside the vessel (i.e., logarithmic wall function) (Knoerzer et al. 2007; Juliano et al. 2009).
5.3.4. Physical Properties of Foods and Other Materials at HPHT Conditions In order to reach good prediction accuracy, CFD models require thermophysical properties to be included as a function of pressure and temperature. For food and other polymeric materials, the thermal expansivity, specific heat, density, viscosity, and thermal conductivity at high-pressure and hightemperature conditions are mostly unknown. However, the properties have been published for water, some oils and alcohols, and some insulating polymeric materials (Harvey et al. 1996; Knoerzer et al. 2010b, 2010c). Information on the dependency of thermophysical properties for food and other materials with pressure and temperature can be found in Chapter 2 as well as other references (Juliano et al. 2008b; Knoerzer et al. 2010b, 2010c).
The above-mentioned thermal and transport properties of water were extracted from the NIST/ ASME database (Harvey et al. 1996) to assess their variation with pressure (Juliano et al. 2008b), based on a compression heating of 4.6°C/100 MPa at an initial temperature of 75°C. Figure 5.4 shows 3D representations of thermal expansivity, specific heat, and density as a function of temperature and pressure. The thermal expansion coefficient α and the specific heat capacity Cp have shown to be more sensitive to temperature than to pressure, whereas density ρ has shown to be more affected by pressure change. During come-up time, α gradually decreased by 28% when reaching 700 MPa and 105°C, in comparison to its value at atmospheric pressure and temperature 75°C. Similarly, Cp was reduced by 12% and ρ was increased by 15 to 18%. Thermal conductivity k has shown an increase of 44% at 700 MPa and 105°C, at a similar rate as temperature increases, transferring heat 1.4 times faster than water at atmospheric pressure and temperature of 75°C. Similarly, thermal diffusivity increased as water was pressurized, following the same trend as thermal conductivity and the increase in temperature due to compression. Zhu et al. (2007) also found an increase in thermal diffusivity with increased pressure, not only in water but also in potato and cheese. The term in Equation 5.4 containing the ratio αp/(Cp·ρ), or kC as referred to in Knoerzer et al. (2010b, 2010c), has shown to be less variable with pressure than the conduction term containing the thermal diffusivity (Juliano et al. 2008b) for water at initial temperatures of 75°C. Knoerzer et al. (2010b, 2010c) reported that kC, and therefore compression heating, of glycol-water mixtures and some insulating polymers is mainly dependent on pressure, whereas water and PTFE also show pronounced dependence on temperature. Viscosity showed a small relative increase with pressure increase (6%) to 700 MPa and 105°C, behaving similarly to atmospheric pressure, while showing significant decrease (25%) if heated from 75 to 99°C at atmospheric pressure. If cooling down would occur during holding time at 700 MPa (e.g., from target 105°C to the chamber temperature of
Chapter 5
Computational Fluid Dynamics in High-Pressure High-Temperature Processes
Density (kg/m3)
1200 1150 1100 1050 1000 950 360 Tempe
600 200 400 Pa) (M e ur ss Pre
380 rature (K
)
x 10–4
Expansivity (1/K)
6.5 6 5.5 5
83
75°C), properties (ρ, Cp, α, γ ) would show only small variations (1–6%) except for the viscosity, which would increase by 39% (Juliano et al. 2008a). The heat transfer coefficient h is used to quantify the transfer rate of heat by convection from a liquid to the surface of the food and pouch. It enables evaluating the effectiveness of heat transfer in processes through the evaluation of overall resistances participating in the system under study. In particular, in HPHT processing this property is used to calculate the heat transferred between the food package and the surrounding fluid. Heat transfer coefficients can be extracted from empirical relations between dimensionless Nusselt, Prandtl, and Reynolds numbers according to laminar or turbulent conditions (Perry 1997). However, not much information has been published on the validity of empirical equations, as applied to extracting heat transfer coefficients at high-pressure conditions. Different regions inside the vessel may require a particular equation (including dimensionless numbers) at the boundary to represent accurate heat transfer coefficients.
4.5 600 200 400 Pa) (M e ur ss Pre
Specific heat capacity (kJ/kgK)
360 Tempe 380 rature (K 400 ) 4.2 4.1 4 3.9 3.8
200 400 600 Tempe rature (K )
400
360 380 Pa) (M e Pressur
Figure 5.4. Response surface plots of thermophysical properties of liquid water at increasing pressure and temperature, according to compression heating rate of 4.5°C/100 MPa. Properties were calculated from NIST/ASME Properties database (Adapted from Juliano et al. 2008b). Units: temperature [°C]; density (kg/m3); specific volume (m3/kg); Cp (kJ/K·kg); compressibility (1/MPa); expansion coefficient (1/K); thermal conductivity (W/m·K); viscosity (Pa·s).
5.3.5. Other Important Assumptions Related to Components and Materials inside the HPHT Vessel In order to design a model that predicts chamber temperature profiles during pressurization, a number of assumptions need to be made. The assumptions made for a particular vessel system should provide the closest prediction of the process as influenced by factors such as the vessel design and plant system, insulation, and compression medium composition. (Juliano et al. 2008b) Initial temperatures in the vessel furnace (if present), the fluid surrounding the polymeric carrier, the polymeric carrier inner fluid, and food packages forming the system ought to be assumed homogeneous, at rest, and at thermal equilibrium. Liquids can be assumed Newtonian, compressible and chemically inert. In addition, most pressure pump systems increase the pressure inside the vessel at a constant rate; therefore, the pressurization rate as well as pressure release rate can be assumed constant (Otero et al. 2000; Carroll et al. 2003).
84
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
It can also be assumed that the steel vessel has a predefined constant volume, thus neglecting the expansion of the pressure vessel due to associated pumping during compression. Moreover, it should be noted that vessel expansion may add several percentage points in fluid to the vessel’s volume (Otero and Sanz 2003). Furthermore, for good accuracy, the vessel walls having variable temperature over the wall surface during pressure application need to be taken into account (Hartmann et al. 2004). The increase of mass in the pressure medium and consequent volume reduction in the samples can be neglected (i.e., volume is assumed constant and density is a function of pressure). In particular, deformation of packages should obey a prescribed dynamic. Packages are assumed to have no headspace (after preheating) and volume changes due to air compression should be negligible. The compression heat generated can be assumed dissipated by a combination of conduction and convection within the pressurizing fluid and turbulence may be included where applicable (Knoerzer et al. 2007). Furthermore, consideration of the temperature of the incoming fluid is necessary since convective currents play a major role in the temperature value achieved as well as uniformity (Hartmann et al. 2003; Knoerzer et al. 2007; Juliano et al. 2009). In addition, if unknown, the compression heating effect of the packaging material layer surrounding the food may be assumed to be similar to water. A further assumption is that the food does not change its composition, structure, and phase state between initial and termination points of the process (Farkas and Hoover 2000). Package disturbance by flow of the incoming pressure fluid may be neglected and can be assumed geometrically distributed and fixed within the vessel. The location, size, and shape of the samples should be defined to establish boundary conditions. An initial approximation due to the cylindrical shape of the vessel could be to have a cylindrical type of package for an axis-symmetric model (Hartmann and Delgado 2003b; Juliano et al. 2009). Gravity influence, however, cannot be assumed as negligible, especially during holding stage. Natural convection is mainly influenced by gravita-
tional forces (Knoerzer et al. 2007). Preheating and high-pressure processing times may be assumed constant (i.e., constant fluid inlet velocity for a single pressurization step). Laminar or turbulent conditions will depend on the inlet geometry and velocity. Input variables for the model may be the initial temperature inside the product and vessel (Ts), target pressure P1, pressurization rate, holding time (tp1 – tp2), and decompression rate (Figure 5.1).
5.4. Prediction of Temperature Uniformity and Flow by Means of CFD Modeling CFD, a computer-aided analysis of fluid conservation laws (mass, momentum, energy), is a convenient modeling approach for the prediction of temperature and flow during the HPHT processes in two or three dimensions. It allows the simulation of a process for devices (solid and semisolid structures) that interact with fluid, by solving the governing equations for fluid flow and heat transfer (Eqs. 5.4, 5.5, and 5.6). These partial differential equations describing the entire system are transformed into a system of equations and solved numerically to approximate the exact solution (Nicolaï et al. 2001). The underlying methods for the numerical analysis are the finite volume, finite element, and finite difference methods described elsewhere (Juliano et al. 2008b). These discretization methods provide a solution for a “discrete” number of points (or grid), where conservation equations are applied. In all cases, computational grids are tailored to provide a “mesh-independent” solution for the numerical approximation of the governing equations. Several authors have done extensive research into developing discrete CFD models that predict transient temperature and flow distributions, uniformity, and the loss of compression heating through the high-pressure vessel walls during all high-pressure processing steps (Denys et al. 2000a, 2000b; Hartmann and Delgado 2002a, 2003a; Hartmann et al. 2003, 2004). Some recent models include solid materials (Knoerzer et al. 2007; Otero et al. 2007; Juliano et al. 2009), whereas some predict temperature distribution in three dimensions (Ghani and
Chapter 5
Computational Fluid Dynamics in High-Pressure High-Temperature Processes
Farid 2007) and at high-pressure sterilization conditions (Knoerzer et al. 2007; Juliano et al. 2009). Due to the vertical configuration of the modeled laboratory- and pilot-scale vessels, simulations included a vertical pressure fluid inlet near the center bottom (Hartmann 2002; Hartmann and Delgado 2002b, 2003a, 2003b; Hartmann et al. 2004; Knoerzer et al. 2007; Otero et al. 2007). Thus, in most cases, 2D cross-sections were used as the computational domain (Figure 5.3) similar to that in Figure 5.3 due to rotation symmetry at the central axis. Examples described in this section use the finite elements and finite volume methods to develop CFD models. They will show how CFD models were developed and applied to evaluate the effects of varying inlet velocities, presence of packages, vessel size, and presence of sample carriers on temperature and flow distribution during and after HPHT processing.
5.4.1. Effect of the Inlet Velocity at Laminar Conditions In indirect high-pressure systems a certain amount of fluid is pumped into the already filled vessel, further increasing the amount of fluid to reach the target pressure level. The velocity at the inlet, where the pressure fluid is pumped into the vessel, determines the pressure come-up time. It has been found that the velocities used in a micro 4-mL vessel modeled by Hartmann (2002) provided laminar flow at the inlet, whereas a 35-L pilot-scale vessel modeled by Knoerzer et al. (2007) gave turbulent conditions at the inlet region, as will be shown later. A study on low-temperature conditions (Hartmann and Delgado 2002a) analyzed the thermo- and fluiddynamic effects of the pressurizing fluid (water) in a high-pressure vessel by numerical simulations. Temperature and fluid velocity profiles were modeled in a 4-mL chamber, pressurizing up to 505 MPa with an initial temperature of 15°C and pressure-holding time of 200 s at three inflow velocities (2, 4, and 8 mm/s). The process simulations were based on a numerical solution of fluid dynamics, using the finite volume method in a CFX 4.4 commercial package from AEA technologies (Pittsburgh, PA). The velocity
85
profile was maintained constant at the inlet crosssection for each case, giving a parabolic velocity profile further downstream in the inlet tube. In the inlet tube, velocity was zero at the surrounding wall, reaching a maximum value at its central axis. The flow field obtained inside the micro vessel, a low-temperature vessel, was governed by forced convection. Within a close region around the inlet, the entering fluid underwent a strong deceleration, resulting in a nonuniform temperature distribution. Temperature gradients caused a nonhomogeneous density distribution that generated a buoyancyinduced fluid motion (natural convection due to the gravitational field). Very low inlet velocities gave near isothermal conditions inside the vessel, that is, no temperature rise due to compression occurring in the system. However, a faster compression rate gave a temperature increase, which was close to the maximum adiabatic conditions. Validation was performed with a temperature probe, which was placed in the central plane near the wall. The numerical values were fitted within the error range of 0.7 K of the experimental values throughout the whole process, which attributed to the uncertainty of the manual positioning of the temperature probe (± 1 mm) and temporal resolution of the thermocouple (approximately 2 s), thus showing good agreement with experimental data.
5.4.2. Modeling at HPHT Turbulent Flow Conditions Knoerzer et al. (2007) used the finite element method (COMSOL Multiphysics, COMSOL AB, Stockholm, Sweden) to model a much higher inlet velocity of 5.7 m/s velocity for a 35-L pilot-scale vessel only filled with water, which corresponded to a Reynolds number of 60,000, creating turbulent flow in the vessel bottom region. In this case, the pronounced turbulent region with arising eddies (and therefore increased thermal conductivity, also referred to as turbulent thermal conductivity) provided significant cooling during pressure come-up and holding steps. Thus, opposite from what was observed by Hartmann (2002) in a small vessel at laminar conditions, higher inlet velocities (at turbulent conditions) in the larger
86
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
vessel still hindered the system from achieving maximum compression heating. To account for turbulence, the equations for energy and momentum conservation were extended by further terms, taking into account the contributions of arising eddies (increased thermal conductivity due to mixing and increased dynamic viscosity due to increased shear). To solve this flow problem, an averaged representation was necessary, which was done by employing Reynolds Averaged NavierStokes (RANS) equations (Nicolaï et al. 2001; COMSOL Multiphysics 2006), comprising terms that include average velocity and pressure values and a fluctuating term represented by the Reynolds stress tensor. In particular, Knoerzer et al. (2007) applied the k-ε model, a commonly used stochastic turbulence model for industrial applications, by including an additional “turbulent viscosity” term to the equations expressing conservation of momentum and continuity as described elsewhere (Juliano et al. 2008a). A cylindrical carrier, used to preheat the product to the initial target temperature and transport the packages into a (pilot-scale) vessel, can act as a barrier to flow of incoming colder fluid into the package area. In particular, carriers made of solid polymeric materials may prevent heat losses to the vessel walls and to the top and bottom areas of the pressure vessel. Knoerzer et al. (2007) simulated the temperature distribution obtained after placing two types of food carriers inside a 35-L pilot-scale sterilization, that is, a metal composite carrier (developed in the original design of the vessel to operate with a furnace) and a PTFE carrier. They simulated all processing steps in the 35-L vessel filled with water pressurized to 600 MPa and 415 s pressure holding (at an initial temperature of 90°C). To validate the simulated temperatures, a 3 × 3 thermocouple array placed in an axis-symmetric plane was set up in randomized form at several runs. An example of the modeling domain and temperature distribution is shown in Figure 5.3. The models included a compression heating term from Equation 5.3 and thermal properties such as density, specific heat, and thermal expansivity as functions of temperature and pressure.
The simulations showed significant cooling down (up to about 40°C) below the carrier due to the colder turbulent incoming fluid and demonstrated that both carriers provided a barrier against cooling down (Figure 5.5). However, the lower region inside the metal carrier was colder and, therefore, an uneven temperature distribution was observed and validated. An excellent correlation (R2 = 0.97) was obtained by comparing predicted and measured values in a parity plot, which included all locations of the thermocouples at all time steps throughout the process. On the other hand, the carrier made of PTFE was able to retain most of the compression heat generated even during holding time throughout its entire volume, providing better insulation than the metal carrier (Figure 5.5) at the end of pressure holding. The axis-symmetric model was further developed (Juliano et al. 2009) by including the steel vessel walls, the vessel lid, and the cylindrical packages containing a “water-like” solid. The initial temperature of the vessel lid was considered lower since for the actual process it does not include a heating source. As expected, this addition lowered the temperature at the upper region of the vessel and increased the natural convection.
5.4.3. Effect of the Vessel Size Hartmann and Delgado (2003b) developed models of different sized vessels (micro-scale [0.8 L], pilotscale [6.3 L], and semi-industrial-scale [50.3 L]) to study the effect of scale on temperature distribution. The models included five packages in each vessel containing an enzyme solution and equally distributed through the chamber height, operating at 550 MPa and 40°C. More heat retention was found in packages contained in the larger 50.3 L vessel, resulting in an average temperature difference per package of around 7 K compared with the 0.8 L vessel and 4 K compared with the 6.3 L vessel (Figure 5.6). Lower temperatures were mainly attributed to the incoming “cold” pressure medium, which was less influential in a larger scale vessel with bigger packages. Our group has compared the temperature distribution predicted by a CFD model representing to
Chapter 5
Computational Fluid Dynamics in High-Pressure High-Temperature Processes
87
Carrier opening
1.25
Time=425 Surface: Temperature (K)
1.25
1.2
1.2
1.15
1.15
1.1
1.1
1.05
1.05
1
1
0.95
0.95
0.9
0.9
0.85
0.85 0.8 0.75
0.7
0.7
0.65
0.65
0.55 0.5
Vessel wall
0.6
Central axis
0.8 0.75
0.4
0.35
0.35
0.3
0.3
0.25
0.25
0.2
0.2
0.15
0.15
inlet 0 –0.13 –0.1 –0.07 –0.04 –0.01 0.02
385
380
375
370
365
0.5 0.45
0.05
390
0.55
0.4
Carrier bottom
Max: 394
0.6
0.45
0.1
Time=415 Surface: Temperature (K)
360
355
350
0.1 0.05
(a) Metallic composite carrier
0 –0.13 –0.1 –0.07 –0.04 –0.01 0.02
345 Min: 343
(b) PTFE carrier
Figure 5.5. Thermal profile of two CFD models of a 35-L vessel at the end of holding time (415 s) at 600 MPa including: (a) a metal composite carrier and (b) a PTFE carrier at the end of holding time (adapted from Knoerzer et al. 2007).
scale an Avure 35-L sterilization vessel with a model representing a Stansted 3-L sterilization vessel, both with compression fluid entering at the bottom of the vessel and containing a PTFE carrier with an opening at the top and run at the same conditions (initial
temperature of 90°C and final pressure of 600 MPa; come-up time 130 s; holding time 315 s; decompression time 15 s; Figure 5.7). The predictions show the higher heat retention provided by the 35-L unit due to a more pronounced loss of heat in the 3-L vessel
88
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
322 K
317.5 K 0.8 L
6.3 L
313 K
50.3 L Figure 5.6. Temperature distribution in vessels of different scales (0.8, 6.3, and 50.3 L) at the end of the process (1,200 s; adapted from Hartmann and Delgado 2003b).
(a)
(b)
T (°C) Vessel wall
110
Vessel wall
3-L unit
35-L unit
100 90 80 70 60 Carrier walls Figure 5.7. Comparison of the temperature distribution predicted by CFD models of two high-pressure sterilization vessels including a PTFE carrier at the end of 315 s holding time (initial temperature 90°C and 600 MPa): (a) a 35-L vessel; (b) a 3-L vessel (not to scale). See color insert.
during pressurization (Figure 5.8a). In this case, the model assumes no compression heating of PTFE at the carrier region, which might assist in diminishing the heat loss rate inside the 3-L vessel.
5.5. Distribution of Process Sterility by Coupling with Kinetic C. botulinum Inactivation Models CFD software packages can assist not only in calculating temperature evolution but also in coupling governing equations of fluid dynamics with kinetic inactivation equations to predict enzyme and microbial inactivation distribution from temperature distributions. Coupling with inactivation models can be done either internally (solved simultaneously within the software package) or externally (by converting the transient temperature profile predicted by the CFD model into a parameter representing the extent of inactivation). An equation describing the temporal and spatial enzyme activity or microbial inactivation distribution (Eq. 5.9) can be coupled to determine the inactivation distribution or relative retention throughout the vessel volume at different times (Hartmann et al. 2003). ∂A ∂A ∂A ∂A +u +v +w = K ( P, T ) A ∂t ∂x ∂y ∂z
(5.9)
where A is the relative enzyme activity or microbial load (actual value related to initial value); K(P,T) is the inactivation rate constant; and u, w, and v are the components of the fluid velocity vector in the x-, y-, and, z-directions, respectively. The left-hand side contains the coupling between A and the flow field, that is, the velocity of the solution. The right-hand side represents the coupling of A and the temperature distribution. The following subsections describe the prediction of C. botulinum inactivation distribution, in a 35-L sterilization vessel, accounting for some of the effects discussed in the sections above.
5.5.1. Effect of Carrier Composition Knoerzer et al. (2007) evaluated the C botulinum spore inactivation distribution inside a vessel, as shown in Figure 5.9 for three scenarios: (1) vessel without carrier, filled only with water; (2) vessel with metal carrier; and (c) vessel with PTFE carrier. The temperature component was used to calculate
130
600
120
500
110
400
100
300
90
200
Pressure (MPa)
Temperature (°C)
(a)
Pressure 35-L unit 3-L unit
100
70 0
100
200 300 Time (s)
400
(b)
0.6
1000
300
900
0.5
250
800
Height (mm)
700
Height (mm)
0 500
600 500 400 300 200
0.4
200
0.3
150
100
0.2
50
0.1
100 20 40 60 Width (mm)
20 Width (mm)
35-L unit
3-L unit
ITD = 0.50
ITD = 0.24
40
Integrated Temperature Distribution
80
0
Figure 5.8. Heat retention performance in two CFD models representing the inside of water contained in PTFE carriers in a 35-L unit and in a 3-L unit: (a) predicted temperature profiles in a central vessel point of each vessel; (b) integrated temperature distributor (ITD) distribution value throughout an axis-symmetric cross-section of the vessels at the end of the HPHT process.
89
90
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
log S 0 –2 –4 –6 –8 –10 –12
(between 2 and 9 log reductions). For the insulated PTFE carrier, over 94.6% of the carrier ’s length showed more than 12 (up to 14) log reductions in C. botulinum spores (Figure 5.9). Based on the increased extent of inactivation observed when using an insulated carrier, this type of model can be of great assistance in finding an optimum carrier design that produces thermal uniformity and uniform spore inactivation throughout the carrier, as well as optimum processing times. Section 5.6.2.2 will show the application of these models to determine optimum carrier wall thickness.
5.5.2. Comparison of the Model Output Based on the Selected Inactivation Kinetics
–14 (a) without
(b) metal
(c) PTFE
carrier
Figure 5.9. Predicted distribution of extent of C. botulinum log reduction extent inside a 35-L pilot-scale high-pressure vessel in three scenarios: (a) vessel without carrier, (b) vessel including a metal composite carrier, and (c) vessel including a Teflon (PTFE) carrier (from Knoerzer et al. 2007). See color insert.
the F-value, which was transformed into inactivation values by using Equation 5.10. t
F = ∫ 10
T (t )−Tref zT
dt = D@T =Tref ⋅ log S.
(5.10)
0
where F is the time the material would be held at a Tref of 121.1°C to achieve the same microbial inactivation of the process, zT is the temperature increment that changes the rate of the process by a factor of 10, S is the survival ratio N/N0 (N and N0 are the final and initial number of spores), and D@T =Tref the time at Tref to lower the number of spores by a factor of 10. The traditional first-order inactivation kinetics can also be expressed as: log S (t ) = −10
T (t )−Tref zT
⋅
t D@T =Tref
(5.11)
In the vessel without a carrier, inactivation distribution yielded less than 1 log reduction while an inhomogeneous distribution was seen in the metal carrier
Juliano et al. (2009) developed a more detailed CFD model, as described in Figure 5.10. This model was applied as a platform to compare the performance of known C. botulinum inactivation kinetic models for predicting inactivation distribution. In addition to the previously considered linear kinetic model including the F-value (Eq. 5.11), the Weibullian model (Eq. 5.12), an nth-order model (Eq. 5.13), and a combination of the nth-order model and the log linear model were selected. log S (t ) = −b [T ] ⋅ t n′[T ]
(5.12)
where b[T] and n′[T] are temperature-dependent parameters. Assuming that spore inactivation is only affected by temperature, these parameters can be expressed as function of the thermal history before, during, and after pressurization. Furthermore, inactivation of a selected thermo-baroresistant C. botulinum strain has been expressed as a function of both temperature and pressure in an nth-order model (Margosch et al. 2006). dN (t ) = − ki (T , P ) ⋅ N n dt
(5.13)
A reaction order of 1.35 was found by fitting k to curves obtained at different pressure–temperature combinations of 70–120°C and 600–1,400 MPa as well as ambient pressure. Single values of each constant at each combination were condensed into:
Chapter 5
(a)
Computational Fluid Dynamics in High-Pressure High-Temperature Processes
Z
91
(b) Time=350 Surface:Temperature [K] Max: 394 Arrow: Velocity field [m/s]
r
1.4
390
1.35
metal lid
1.3 1.25
top water entrance
380
1.2 1.15
air layer
1.1
1
370
1.05 1 0.95
2
0.9 stainless steel
0.85 3
0.8 0.75 0.65 0.6
340
0.55
5
0.5 0.45 6
330
0.4 0.35
PTFE carrier
350
0.7
4
water
360
0.3
7
320
0.25 0.2
metal valve
0.15
310
0.1 0.05 0
300
–0.05 –0.34 –0.26 –0.18 –0.1 –0.02 0.06
Min: 293 water inlet Figure 5.10. CFD model of a 35-L vessel including carrier, packages, steel walls, and metal lid: (a) computational domains of the model structure and (b) thermal and flow profile in the vessel at the end of holding time (315 s) at 600 MPa (from Juliano et al. 2009). Conditions simulated include starting temperature and pressurization rate to a final pressure of 600 MPa and a holding time of 315 s. Arrows proportional to the maximum velocity at specific time. See color insert.
ki′ (T , P ) = e A0 + A1⋅P + A2 ⋅T + A3 ⋅P
2 + A ⋅T 2 + A ⋅P⋅T + A ⋅P⋅T 2 4 5 6
(5.14)
where k ′ = ki′ (T , P ) = ki ⋅ N 0n−1 (Margosch et al. 2006). The rationale for comparing the performance of these inactivation models is due to the questionable
validity of the traditional F0 method, which assumes first-order kinetics for the inactivation of C. botulinum and the linearity of the D-value curves as a function of temperature (constant zT; Peleg, 2006). Furthermore, an HPHT process most likely requires
92
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
an expression that accounts for the possible combined effect of pressure and temperature. The kinetic models were expressed in the form of an ordinary differential equation (Eq. 5.15) that was externally coupled with the CFD model temperature output through the MATLAB routine also used by Knoerzer et al. (2007), which allowed predicting inactivation for non-isothermal scenarios. d [ log S (t )] = f [ log S (t )] dt
(5.15)
where f is a generic function of logS(t), S being the survival ratio N/N0, and N and N0 the final and initial number of spores. The routine fitted the temperature data to give a function T(t) in all locations inside the vessel, and was subsequently substituted in the differential equation, which was then solved for the total time of the process. The output of this routine was capable of providing: (1) log S(t) versus t plots at different locations, (2) log S(x,y) distributions at specific times, and (3) log S(x,y,t) versus t animations.
Table 5.1 summarizes the microbial inactivation models used (A: traditional first order log-linear kinetics model; B: Weibullian model; C: nth-order kinetics model; D: combined log-linear/nth-order model) expressed in Equation 5.15 and includes the respective parameter values for C. botulinum. The log-linear first order and Weibullian models originated from C. botulinum inactivation data at near atmospheric conditions and, therefore, only accounted for the temperature variation. On the other hand, the nth-order model was obtained from C. botulinum inactivation data corresponding to several combinations of temperature and pressure (Margosch et al. 2006) and thus depended on both temperature and pressure. Considering that the nth-order model was only valid above 100°C in the pressure range 0.1 to 600 MPa, a combined discrete model was tested, which solved for log-linear kinetics at temperatures equal to or less than 100°C and for nth-order kinetics at temperatures higher than 100°C (Table 5.1).
Table 5.1. Description of selected C. botulinum inactivation models and their parameter values for comparison in a CFD model platform of a 35-L high-pressure system (adapted from Juliano et al. 2009).
Model A—Linear kinetics B—Weibull distribution C—nth-order kinetics
D—combined linear nth order
d [ log S (t )] dt
Parameters for C. botulinum
T (t )−Tref
−
Tref = 121.1°C zT = 10°C D@T =Tref = 12.6 s
10 zT D@T =Tref
−b [T (t )] ⋅ t
n′[T (t )]
−10( n −1) ⋅ log S (t ) ⋅
⎧ log S (t ) ⎫ ⋅ ⎨− ⎬ ⎩ b [T (t )] ⎭
n′[T (t )]−1 n′[T (t )]
ki′[T ( t ) , P ( t )] ln (10 )
T (t ) − Tref ⎤ ⎡ k ′[T ( t ) , P ( t )] ⎥ 10 zT ⎢ if ⎢T ≤ Tc , − , − 10( n −1) ⋅ log S (t ) ⋅ i ⎥ ln (10 ) D@T = Tref ⎥⎦ ⎢⎣
b [T (t )] = ln {1 + e0.3⋅[T (t )−102.3] } 0.425 n ′ [T (t )] = 0.325 + 1 + e0.0994⋅[T (t )−101] ki′[T (t ) , P (t )] = e A0 + A1⋅ P + A2 ⋅T + A3⋅P
2 + A ⋅T 2 + A ⋅P⋅T + A ⋅P⋅T 2 4 5 6
where n = 1.35 A0 = 2.456 ; A1 = −0.023 ; A2 = −0.149 ; A3 = 2.259 × 10 −5 ; A4 = 1.462 × 10 −3 ; A5 = 1.798 × 10 −4 ; A6 = −1.806 × 10 −7 Refer to models A and C Tc = 100°C is the critical temperature when model A switches to model C
A—from (Pflug 1987); B—from (Campanella and Peleg 2001); C—from (Margosch et al. 2006).
Chapter 5
(a)
(b)
(c)
Computational Fluid Dynamics in High-Pressure High-Temperature Processes
(d)
log S 0
–2
–4
–6
–8
–10
–12
–14
–16
Figure 5.11. Predicted distribution of C. botulinum log reduction extent according to four selected kinetic inactivation models using a CFD model platform for a high-pressure 35-L sterilization system: (a) traditional log-linear kinetic model, (b) Weibull distribution model, (c) nth-order kinetic model, and (d) combined discrete log-linear and nth-order kinetic model (adapted from Juliano et al. 2009). See color insert.
The distribution of C. botulinum inactivation log reduction predicted by each model from the CFD platform for the 35-L vessel is shown in Figure 5.11. The final inactivation calculated inside each package when using model A (log-linear kinetics) was 16.5 log reductions; model C (nth-order kinetics) and model D (nth-order and combined log linear/nth order) achieved approximately 12.0 log reductions; model B (Weibull) achieved only around 9.4 log reductions at the end of the process. Hence, the conventional thermal processing kinetics (not accounting for the
93
combined effects with pressure) required shorter holding times to achieve a 12D reduction of C. botulinum spores compared with the other models. However, the temperature distribution inside the vessel resulted in a more uniform inactivation distribution when using the Weibull model or nth-order kinetics model, compared with the log-linear kinetics model (Figure 5.11). The lower inactivation and more uniform distribution provided by models B, C, and D (Table 5.1) can be explained by (1) the tailing of curves given by the model parameters and (2) the fact that only data from different C. botulinum strains were available and used in each model. Furthermore, the Weibull model (B) only accounted for the temperature variation, not pressure, which also affected the outcome. This showed how the CFD platform became quite useful in evaluating and comparing the inactivation extent and uniformity provided by different C. botulinum inactivation models in the same system. Inactivation models used in different food media and accounting for the heat transfer effect of the selected package during the preheating step, to be developed in the future, could be evaluated through such CFD platforms. These CFD platforms could be used as an aid for regulatory filing of the technology as well as in process and equipment design.
5.6. Dimensionless Parameters to Express the Process Performance In order to evaluate the performance of a highpressure process and make comparisons to others, a dimensionless parameter able to predict temperature uniformity during treatment inside the processing vessel is more convenient. It is desirable that this process performance parameter can assist in (1) providing the extent of “commercial sterility” achieved throughout the volume of prepackaged food contained in the vessel; (2) predicting the quality degradation as a result of temperature (pressure) use; and (3) HPHT process design and validation. Aspects of the HPHT process include thermal process evaluation based on container size and shape, food composition, equipment modification and optimization, scale-up studies, energy use, modification and
94
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
optimization of process conditions, and others. (Juliano et al. 2008b). This section will describe two performance parameters that have been able to characterize the process uniformity (Hartmann and Delgado 2003b; Knoerzer et al. 2010a).
This type of measure of process uniformity is useful for comparing whole pouches, but gives no information on uniformity inside the pouches.
5.6.1. Process Uniformity Λ
To overcome this limitation and in order to conveniently evaluate a process with respect to temperature performance, a parameter that accounts not only for temperature profiles in discrete locations (i.e., a package, a carrier, or the whole vessel), but also for the temperature variations across the entire volume has been proposed (Knoerzer et al. 2010a). The so-called ITD value is an expression for process performance that represents the temperature distributions in relation to a target temperature during HPHT throughout the whole vessel volume.
Hartmann and Delgado (2003b) conducted a proportional scale-up study through CFD modeling, but in this case, modeled the use of five packages containing enzyme solution in the 0.8-, 6.3-, and 50.3-L vessels (Figure 5.6). Equation 5.16 was used for predicting the inactivation of B. subtilis α-amylase. Process uniformity Λ was defined as the ratio of the minimum ( Α ave _ min ) and maximum ( Α ave _ max ) average activity retention per package in all five packages: Λ=
Α ave _ min Α ave _ max
(5.16)
Table 5.2 describes the uniformity values obtained for each vessel volume while varying the heat transfer coefficient hpp of the packaging material at the boundary of each package. Process uniformity for the 0.8-L vessel did not depend on hpp, whereas the other larger vessels were greatly affected. The lowest heat transfer coefficients provide more inactivation uniformity between packages because heat is retained better inside the packages for a major part of the process. For instance, a uniformity of 0.97 for the 50.3-L vessel indicates that heat is retained inside the package throughout most of the process, leading to a high degree of inactivation and uniformity.
Table 5.2. Process uniformity for simulated vessel volumes and heat transfer coefficients (adapted from Hartmann et al. 2003). hpp (W/m2·K) Λ (–) Vessel volume (L)
0.8 L 6.3 L 50.3 L
1 × –10−4
1 × –10−3
1 × –10−2
0.86 0.90 0.97
0.84 0.78 0.81
0.84 0.74 0.69
5.6.2. The Integrated Temperature Distributor (ITD)
5.6.2.1. Concept and Determination Method Commercial thermal processing is currently characterized by using the F-value (thermal death time; Eq. 5.10) to relate the temperature history of a process to a reference temperature for target bacterial spore inactivation (e.g., C. botulinum; Bacillus stearothermophilus). In this case, zT (°C) represents the thermal resistance constant using the following model: zT = −
(T − Tref )
( log Dref − log D )
(5.17)
where the reference decimal reduction time Dref (minute) is at a reference temperature Tref (°C), within the range of temperatures T (°C) used to generate experimental data. The decimal reduction time D (minute) of the target microorganism at a given temperature is expressed as: D=
t log N ref − log N
(5.18)
where N is the number of survivors (typically colony forming units [CFU] per gram or mL) at time t, and Nref is the initial number of microorganisms (Ball 1943). As stated earlier, the F-value model has been questioned due to the assumption of the linearity of
Chapter 5
Computational Fluid Dynamics in High-Pressure High-Temperature Processes
According to F-value …
Transient temperature profiles throughout carrier volume
Tdt
H
ITD(r,z) = 10
Integrated temperature distribution
Integrated profile relative to target T and holding t dz
[…] […] […]
Integration of integrated profile per row R
dr
array
Integration of integrated columns per row
Ttarget = Tmax,adiabatic thold = 300 s
ITD value
(a)
(b)
carrier height/mm
[…] […] […]
0
thold
Ttarget 10
[…] […] […] […] […] […]
ROI
95
1000 900 800 700 600 500 400 300 200 100
0.6 0.5 0.4 0.3 0.2
0.1 20 40 60 carrier radius/min (c)
Figure 5.12. ITD value determination in a high-pressure process (at discrete time): (a) depiction of region of interest (ROI, purple); (b) flowchart a MATLAB routine for determination; and (c) example output of an integrated temperature distribution (adapted from Knoerzer et al. 2010a).
the inactivation kinetics of target bacterial spores to very low numbers as well as the linearization of the temperature dependence of the D-value to obtain the zT value (Peleg, 2006). In the case of HPHT processing, a microbial kinetic expression depending on pressure and temperature would be required to provide an accurate representation of the sterility achieved. Moreover, the F-value provides a representation of the level of sterility achieved at a single point in the sterilization unit, not accounting for temperature gradients throughout the unit and, carrier, or package volumes. Therefore, the ITD value has been developed as an expression to evaluate the thermal process performance in an HPHT process throughout the vessel without requiring inputs from microbial kinetic parameters and only accounting for temperature and time data: t
∫ T ( t ) dt 0
tprocess
rmax zmax
ITD =
∫ ∫
rmin zmin
10
−Ttarget
TΔ
drdz
(rmax − rmin ) ⋅ ( zmax − zmin )
(5.19)
where rmin, rmax, zmin, and zmax cover the region of interest (ROI; in this case, the carrier volume), tprocess is the process time of interest (in this case, the holding time where most of the heat loss is expected), TΔ is a temperature gradient of 10 K, and Ttarget is the targeted hold temperature of the process. The ITD is made dimensionless by relating the integrated temperature profiles in each location to the process (holding) time and Ttarget and the surface (volume) integral to the area (volume) of the ROI. The flowchart for the determination of the ITD value is shown in Figure 5.12. Being dimensionless, this expression is universally applicable to any equipment size and process time, making it a convenient tool for comparisons between different types and scales of equipment and processes. Depending on whether the calculation is applied to an axis-symmetric or full 3D temperature distribution, the ITD value represents either the pseudovolumetric 2D or volumetric 3D thermal process performance. The following conclusions can be drawn from the calculated ITD value (in combination with the integrated temperature distribution plot):
96
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
• ITD = 1: perfect target temperature uniformity with respect to process time and distribution • ITD < 1: under processing in some or all parts of the carrier volume • ITD > 1: over processing in some or all parts of the carrier volume 5.6.2.2. Determination of the Optimum Insulating Carrier Wall Thickness with the ITD Value by Using Predicted Temperatures The ITD expression has been successfully utilized for predicting the optimum thickness of a PTFE carrier to be used inside a 35-L vessel (Knoerzer et al. 2010a) such that the best compromise between heat retention and usable volume could be determined. The usable volume VUsable (Eq. 5.20) was increased by decreasing the wall thickness values dwall, with a load capacity between 1.3 and 26.3 L. VUsable = π ⋅ (rcarrier − dwall ) ⋅ hcarrier _ int 2
(5.20)
where rcarrier is the carrier ’s external radius, dwall is the carrier wall thickness, and hcarrier_int is the carrier ’s internal height. By following the procedure shown in Figure 5.12, a carrier thickness value for maximum temperature performance (7 mm) was determined, as well as a compromise value for maximization of usable volume and temperature performance (4 mm). In either case, a significant decrease from the wall thickness of the PTFE carrier originally built for the 35 L vessel (dwall = 28 mm) was determined, suggesting an increase from a 12-L capacity to a 22– 24 L capacity while maintaining ITD values close 0.9 (normalized to the maximum ITD value of the scenarios investigated). Future trials including compression heating values for the polymeric materials and thermal conductivities as function of temperature and pressure will further improve the accuracy of these models.
5.7. Overview and Future Challenges This chapter has described the application of CFD in the prediction of temperature distribution and flow for the design and characterization of heat transfer phenomena occurring in HPHT processes. Particular
attention was given to the loss of compression heat through the metal steel vessel walls and its impact on sterilization performance. It was shown how CFD models can include all parts of the equipment including packages and carrier while representing all steps of the process. CFD models allowed demonstrating how the inlet temperature fluid can influence temperature distribution inside the chamber and how a product carrier can act as a thermal insulator. The importance of material thermophysical properties as a function of temperature and pressure for improved model accuracy was highlighted. Although these property functions have been determined for water and other liquids as well as some insulating plastics, more research is needed to characterize other food, packaging, or carrier materials. CFD models provide the possibility of coupling fundamental equations of fluid motion with kinetic models to determine the extent of microbial or enzyme inactivation or any other process throughout products inside the vessel as well as its impact on quality. CFD models could represent the importance of selected C. botulinum spore inactivation models, and allowed comparison of the thermal effect with the combined pressure thermal effect on temperature distribution achieved. Parameters such as the ITD value can characterize the sterilization performance throughout a volumetric section of the vessel contents and assist in design and process characterization. One challenge ahead is the accuracy of validation tools for these models. Thermocouples have assisted in measuring temperature profiles at specific locations. However, thermocouple systems in many HPHT systems tend to easily fail through their closure connections and therefore comprehensive validation experiments become very time-consuming and, in some cases may lack accuracy. Wireless temperature devices such as a “Thermo-Egg” (Knoerzer et al. 2010d) have been recently developed and are promising accurate results while allowing simultaneous temperature measurement at several vessel points. Measuring thermophysical properties of foods, process fluids, packaging, and construction materials in situ under pressure and elevated temperatures
Chapter 5
Computational Fluid Dynamics in High-Pressure High-Temperature Processes
will further enhance the accuracy and usefulness of the CFD models. The same applies to the process of interest (e.g., microbial inactivation, enzyme inactivation, or biochemical and chemical transformations). Validated kinetic models are needed to couple these to the outputs of the CFD models to predict performance. Conversely, microbial validation has also encountered challenges due to the sometimes erratic behavior of microbial spores during preheating and sterilization. Spore inactivation models considering the preheating stage, which provides conditions for spore germination, will aid in accurate validation of CFDassisted sterility predictions. As CFD software packages become more user friendly, it is foreseen that CFD models will be more frequently utilized for the characterization and design of HPHT processes.
Notation Latin Letters A b CP
D@T =Tref dwall F g h hcarrier,int k K K k n n n N0, N P
Relative activity or actual activity related to the initial activity (%) Function of process temperature and/ or pressure history Isobaric heat capacity (J· kg−1 · K−1) Cp, mixture Specific heat capacity of mixture (J · kg−1 · K−1) Decimal reduction time (minute) Carrier wall thickness (m) Thermal death time (minute) Gravity constant (9.81 m/s2) Heat transfer coefficient (W/m2/K) Internal carrier height (m) First-order kinetic constant (s−1) Inactivation rate constant (s−1) Inverse of inactivation rate constant (s) Thermal conductivity (W·m−1 · K−1) Function of process temperature and/ or pressure history Normal to surface Order of inactivation kinetic Initial and final number of microbial spores Pressure (Pa)
P0 P1, Ptarget P2 Pf prate Pref Q R r, R rcarrier R2 S T t T0 Tc Tf tf Th TL tp Tp1 tp1 Tp2 tp2 Tref ts Ts, Ti TΔ Ttarget u,v,w V Vusable vin x,y,z ZP ZT
97
Atmospheric pressure (Pa) Target pressure (Pa) Pressure at the end of the holding time (Pa) Pressure including a fluctuating term (Pa) Pressure rate (MPa · s−1) Reference pressure (Pa) Volumetric compression heating rate (J·m−3 · s−1) Universal gas constant (8.314 J · mol−1 · K−1) Radius (radial direction, m) Carrier radius (m) Coefficient of determination Survival ratio (N/N0) Temperature (K) Time (s) Initial temperature of sample (K) Temperature after cooling (K) Temperature after decompression (K) Time after decompression (s) Preheating temperature (K) Temperature of fluid (K) Process time (s) Temperature after compression heating (K) Time after compression (s) Temperature at the end of holding time (K) Time after holding stage (s) Reference temperature (K) Start time (s) Initial temperature (K)TV , Twall Wall temperature (K) Temperature gradient (10 K) Target temperature (K) Velocity components in x-,y-, and z-direction (m/s) Volume (m3) Usable volume / load capacity (m3) Inlet velocity (m/s) Spatial directions Pressure sensitivity (Pa) Thermal sensitivity (°C, K)
98
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Greek Letters α, αp β ηT ρ τ
Thermal expansion coefficient (K−1) Compressibility (Pa−1) Turbulent viscosity (Pa · s) Density (kg · m−3) Pressure come up time (s)
Abbreviations 2D 3D ASME CFD CFU HPHT HPP ITD NIST PATP PATS PE PEEK POM PP PTFE RANS ROI UHMWPE
Two-dimensional Three-dimensional American Society of Mechanical Engineers Computational fluid dynamics Colony forming units High-pressure high temperature High-pressure processing Integrated temperature distributor National Institute of Standards and Technology Pressure-assisted thermal processing Pressure-assisted thermal sterilization Polyethylene Polyetheretherketone Polyoxymethylene Polypropylene Polytetraflourethylene Reynolds averaged navier-stokes Region of interest Ultrahigh-molecular-weight polyethylene
Operators d Σ ∂ Δ ∇ ∇·
Differential Sum Partial differential Difference Gradient (nabla-operator) Divergence
References Ardia A, Knorr D, Heinz V. 2004. Adiabatic heat modelling for pressure build-up during high-pressure treatment in liquidfood processing. Food Bioproducts Proc 82(C1):89–95.
Balasubramaniam V, Ting E, Stewart C, Robbins J. 2004. Recommended laboratory practices for conducting highpressure microbial inactivation experiments. Innov Food Sci Emerg Technol 5(3):299–306. Balasubramanian S, Balasubramaniam VM. 2003. Compression heating influence of pressure transmitting fluids on bacteria inactivation during high pressure processing. Food Res Intern 36(7):661–668. Ball CO. 1943. Short-time pasteurization of milk. Ind Eng Chem 35:71–84. Barbosa-Cánovas GV, Juliano P. 2007. Food sterilization by combining high pressure and heat. In: GF Gutierrez-López, G Barbosa-Cánovas, J Welti-Chanes, E Paradas-Arias, eds., Food Engineering (V Iberoamerican Congress of Food Engineering, CIBIA V), 9–46. New York: Springer. Campanella OH, Peleg M. 2001. Theoretical comparison of a new and the traditional method to calculate Clostridium botulinum survival during thermal inactivation. J Sci Food Agric 81(11):1069–1076. Caner C, Hernandez RJ, Pascall M, Balasubramaniam VM, Harte BR. 2004. The effect of high-pressure food processing on the sorption behaviour of selected packaging materials. Packaging Technol Sci 17(3):139–153. Carroll T, Chen P, Fletcher A. 2003. A method to characterise heat transfer during high-pressure processing. J Food Eng 60(2):131–135. Chen XD. 2006. Modeling thermal processing using computational fluid dynamics (CFD). In: DW Sun, ed., Thermal Food Processing, 133–151. Boca Raton: Taylor & Francis. COMSOL Multiphysics. 2006. Chemical Engineering Module. Stockholm, Sweden: COMSOL AB. Datta AK. 2001. Fundamentals of heat and moisture transport for microwaveable food product and process development. In: AK Datta, CA Ramaswamy, eds., Handbook of Microwave Technology for Food Applications, 115–172. New York: Marcel Dekker. Davies LJ, Kemp MR, Fryer PJ. 1999. The geometry of shadows: Effects of inhomogeneities in electrical field processing. J Food Eng 40(4):245–258. Denys S, Ludikhuyze LR, Van Loey AM, Hendrickx ME. 2000a. Modeling conductive heat transfer and process uniformity during batch high-pressure processing of foods. Biotechnol Prog 16(1):92–101. Denys S, Van Loey AM, Hendrickx ME. 2000b. A modeling approach for evaluating process uniformity during batch high hydrostatic pressure processing: Combination of a numerical heat transfer model and enzyme inactivation kinetics. Innov Food Sci Emerg Technol 1(1):5–19. Farkas DF, Hoover DG. 2000. High pressure processing. J Food Sci (Suppl.):47–64. Ghani AGA, Farid MM. 2007. Numerical simulation of solidliquid food mixture in a high pressure processing unit using computational fluid dynamics. J Food Eng 80(4):1031–1042. Gola S, Foman C, Carpi G, Maggi A, Cassara A, Rovere P. 1996. Inactivation of bacterial spores in phosphate buffer and in
Chapter 5
Computational Fluid Dynamics in High-Pressure High-Temperature Processes
vegetable cream treated with high pressures. High Press Biosci Biotechnol 253–259. Hartmann C. 2002. Numerical simulation of thermodynamic and fluiddynamic processes during the high pressure treatment of fluid food systems. Innov Food Sci Emerg Technol 3(1): 11–18. Hartmann C, Delgado A. 2002a. Numerical simulation of convective and diffusive transport effects on a high-pressure-induced inactivation process. Biotechnol Bioeng 79(1):94–104. Hartmann C, Delgado A. 2002b. Numerical simulation of thermofluiddynamics and enzyme inactivation in a fluid food system under high hydrostatic pressure. Trends High Press Biosci Biotechnol 533–540. Hartmann C, Delgado A. 2003a. Numerical simulation of thermal and fluiddynamical transport effects on a high pressure induced inactivation. High Press Res 23(1–2):67–70. Hartmann C, Delgado A. 2003b. The influence of transport phenomena during high-pressure processing of packed food on the uniformity of enzyme inactivation. Biotechnol Bioeng 82(6): 725–735. Hartmann C, Delgado A, Szymczyk J. 2003. Convective and diffusive transport effects in a high pressure induced inactivation process of packed food. J Food Eng 59(1):33–44. Hartmann C, Schuhholz J, Kitsubun P, Chapleau N, Bail A, Delgado A. 2004. Experimental and numerical analysis of the thermofluiddynamics in a high-pressure autoclave. Innov Food Sci Emerg Technol 5(4):399–411. Harvey AH, Peskin AP, Sanford AK. 1996. NIST/ASTME— IAPSW Standard Reference Database 10, version 2.2. de Heij WBC, Van Schepdael LJMM, Moezelaar R, Hoogland H, Matser A, van den Berg RW. 2003. High-pressure sterilization: Maximizing the benefits of adiabatic heating. Food Technol 57(3):37–42. Holdsworth SD. 1997. Thermal Processing of Packaged Foods. New York: Blackie Academic & Professional. Juliano P. 2006. High Pressure Thermal Sterilization of Egg Products. PhD dissertation, Washington State University, Pullman, WA. Juliano P, Li BS, Clark S, Mathews JW, Dunne PC, BarbosaCánovas GV. 2006a. Descriptive analysis of precooked egg products after high-pressure processing combined with low and high temperatures. J Food Qual 29(5):505–530. Juliano P, Toldra M, Koutchma T, Balasubramaniam VM, Clark S, Mathews JW, Dunne CP, Sadler G, Barbosa-Cánovas GV. 2006b. Texture and water retention improvement in highpressure thermally treated scrambled egg patties. J Food Sci 71(2):E52–E61. Juliano P, Clark S, Koutchma T, Ouattara M, Mathews JW, Dunne CP, Barbosa-Cánovas GV. 2007. Consumer and trained panel evaluation of high pressure thermally treated scrambled egg patties. J Food Qual 30(1):57–80. Juliano P, Knoerzer K, Barbosa-Cánovas GV. 2008a. High pressure processes: Thermal and fluid dynamic modeling applications. In: R Simpson, ed., Engineering Aspects of Thermal Processing, 159–207. Boca Raton, FL: CRC Press/Taylor & Francis.
99
Juliano P, Knoerzer K, Barbosa-Cánovas GV. 2008b. High pressure thermal processes: thermal and fluid dynamic modeling principles. In: R Simpson, ed., Engineering Aspects of Thermal Processing, 91–158. Boca Raton, FL: CRC Press/Taylor & Francis. Juliano P, Knoerzer K, Fryer P, Versteeg C. 2009. C. botulinum inactivation kinetics implemented in a computational model of a high pressure sterilization process. Biotechnol Prog 25(1):163–175. Juliano P, Koutchma T, Sui Q, Barbosa-Cánovas GV, Saddler G. 2010. Food plastic packaging for high pressure processing. Food Eng Rev 2(4):274–297. Knoerzer K, Juliano P, Gladman S, Versteeg C, Fryer P. 2007. A computational model for temperature and sterility distributions in a pilot-scale high-pressure high-temperature process. AIChE J 53(11):2996–3010. Knoerzer K, Buckow R, Juliano P, Chapman B, Versteeg C. 2010a. Carrier optimisation in a pilot-scale high pressure sterilisation plant—An iterative CFD approach. J Food Eng 97(2): 199–207. Knoerzer K, Buckow R, Sanguansri P, Versteeg C. 2010b. Adiabatic compression heating coefficients for high-pressure processing of water, propylene-glycol and mixtures—A combined experimental and numerical approach. J Food Eng 96(2):229–238. Knoerzer K, Buckow R, Versteeg C. 2010c. Adiabatic compression heating coefficients for high pressure processing—A study of some insulating polymer materials. J Food Eng 98(1):110–119. Knoerzer K, Smith R, Kelly M, Steele R, Sanguansri P, Versteeg C. 2010d. The Thermo-Egg: A combined novel engineering and reverse logic approach for determining temperatures at high pressure. Food Eng Rev 2(3):216–225. Koutchma T, Juliano P, Song Y, Setikaite I, Patazca E, Dunne PC, Barbosa-Cánovas GV. 2009. Packaging evaluation for high pressure/high temperature sterilization of shelf-stable foods. J Food Process Eng. DOI: 10.1111⁄j.1745−4530.2008.00328 (available online). Krebbers B, Matser AM, Koets M, Berg RW. 2002. Quality and storage-stability of high-pressure preserved green beans. J Food Eng 54(1):27–33. Krebbers B, Matser A, Hoogerwerf S, Moezelaar R, Tomassen M, Berg R. 2003. Combined high-pressure and thermal treatments for processing of tomato puree: Evaluation of microbial inactivation and quality parameters. Innov Food Sci Emerg Technol 4(4):377–385. Leadley C. 2005. High pressure sterilisation: A review. Campden Chorleywood Food Res Assoc 47:1–42. Margosch D. 2005. Behavior of bacterial endospores and toxins as safety determinants in low acid pressurized food. PhD dissertation, Technical University Muenchen-Weihenstephan, Germany. Margosch D, Ehrmann MA, Ganzle MG, Vogel RF. 2004. Comparison of pressure and heat resistance of Clostridium botulinum and other endospores in mashed carrots. J Food Prot 67(11):2530–2537.
100
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Margosch D, Ehrmann MA, Buckow R, Heinz V, Vogel RF, Ganzle MG. 2006. High-pressure-mediated survival of Clostridium botulinum and Bacillus amyloliquefaciens endospores at high temperature. Appl Environ Microbiol 72(5):3476–3481. Matser AA, Krebbers B, Berg RW, Bartels PV. 2004. Advantages of high pressure sterilisation on quality of food products. Trends Food Sci Technol 15(2):79–85. Meyer RS, Cooper KL, Knorr D, Lelieveld HLM. 2000. Highpressure sterilization of foods. Food Technol 54(11):67–72. Nicolaï BM, Scheerlinck N, Verboven P, Baerdemaeker JD. 2001. Stochastic finite-element analysis of thermal food processes. In: J Irudayarai, ed., Food Processing Operations Modeling. Design and Analysis. 265–304. New York: Marcel Dekker. Otero L, Sanz P. 2003. Modelling heat transfer in high pressure food processing: A review. Innov Food Sci Emerg Technol 4(2):121–134. Otero L, Molina-Garcia A, Sanz P. 2000. Thermal effect in foods during quasi-adiabatic pressure treatments. Innov Food Sci Emerg Technol 1(2):119–126. Otero L, Ramos AM, de Elvira C, Sanz PD. 2007. A model to design high-pressure processes towards an uniform temperature distribution. J Food Eng 78(4):1463–1470. Peleg M. 2006. Advanced Quantitative Microbiology for Foods and Biosystems. Models for Predicting Growth and Inactivation. Boca Raton, FL: Taylor & Francis. Perry RH. 1997. Perry’s Chemical Engineers’ Handbook. New York: Mc. Graw Hill.
Pflug IJ. 1987. Using the straight-line semilogarithmic microbial destruction model as an engineering design-model for determining the F-value for heat processes. J Food Prot 50(4): 342–346. Raso J, Barbosa-Cánovas G, Swanson BG. 1998. Sporulation temperature affects initiation of germination and inactivation by high hydrostatic pressure of Bacillus cereus. J Appl Microbiol 85(1):17–24. Rovere P, Gola S, Maggi A, Scaramuzza N, Miglioli L. 1998. Studies on bacterial spores by combined pressure-heat treatments: possibility to sterilize low acid foods. In: NS Isaacs, ed., High Pressure Food Science, Bioscience and Chemistry, 354–363. Cambridge: The Royal Society of Chemistry. Schauwecker A, Balasubramaniam VM, Sadler G, Pascall MA, Adhikari C. 2002. Influence of high-pressure processing on selected polymeric materials and on the migration of a pressuretransmitting fluid. Packaging Technol Sci 15(5):255–262. Ting E, Balasubramaniam VM, Raghubeer E. 2002. Determining thermal effects in high-pressure processing. Food Technol 56(2):31–35. Van Schepdael LJMM, de Heij WBC, Hoogland H. 2003. Method for high pressure preservation. [PCT WO 02/45528 A1.]. Zhu S, Ramaswamy HS, Marcotte M, Chen C, Shao Y, Le Bail A. 2007. Evaluation of thermal properties of food materials at high pressures using a dual-needle line-heat-source method. J Food Sci 72(2):E49–E56.
Chapter 6 Computer Simulation for Microwave Heating Hao Chen and Juming Tang
6.1. Introduction Microwave (MW) heating has been used in many food processing unit operations, including extensive uses in precooking of bacon for food service chains and restaurants, thawing of frozen meat blocks for further processing, and, to a lesser extent, in pasteurization and sterilization of prepackaged foods. Compared with conventional heating methods, MW energy is directly converted to thermal energy in foods, significantly reducing process time. However, MW heating is, unlike conventional surface heating, based on complex Multiphysics phenomena, thus the design of such systems is more complicated. MW propagation and field patterns in foods and MW heating systems are governed by Maxwell’s equations, and analytical solutions are available only for very simple cases that are rarely seen in real-world applications. For realistic problems, numerical techniques such as Finite Difference Time Domain (FDTD) method, Finite Element Method (FEM), and Method of Moment (MoM) are often used in the development of computer simulation models to provide a more accurate insight into the interaction between the heated products and MWs (see also Chapter 7 in this book).
Several early papers (McDonald and Wexler 1972; Wu and Tai 1974; Spiegel 1984) summarize computational methods to study electromagnetic (EM) field distribution. In Wu and Tai (1974), a coupled integral equation was developed to solve a two-dimensional (2D) scattering problem for an arbitrary dielectric cylinder. They employed a pair of electrical fields and normal derivatives at the surface of the scattering objects and then solved the complete set of linear equations by using MoM. In McDonald and Wexler (1972), FEM was employed to solve Helmholtz equations within the computational region for a 2D radiating antenna and a dielectrical object. More complex FEM-based computer simulation models were developed later to study 3D MW heating of stationary packaged foods in domestic ovens (Zhang and Datta 2000). Spiegel (1984) provided a good review on FDTD method for medical applications. FDTD method has several advantages over other numerical methods. It requires relatively low computer memory and computational resources. As such, the FDTD method was used extensively in early studies to solve realistic problems such as temperature response to the MWirradiated human eye (Taflove and Brodwin 1975a, 1975b), response of military crafts to electromagnetic
Innovative Food Processing Technologies: Advances in Multiphysics Simulation, First Edition. Edited by Kai Knoerzer, Pablo Juliano, Peter Roupas, and Cornelis Versteeg. © 2011 by John Wiley & Sons, Ltd. and Institute of Food Technologists. Published by John Wiley & Sons, Ltd. ISBN: 978-0-813-81754-5
101
102
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
(EM) pulses (Kunz and Lee 1978), and temperature rises in biological tissues when exposed to MW fields (Cook 1952; Michaelson 1969; Schwan 1972; Guy et al. 1974; Livesay and Chen 1974). The dielectric properties of foods are temperaturedependent. To gain a more realistic insight into MW heating of foods, it is important to consider the coupling effects between heat transfer and EM field in computer models. Ma et al. (1995) developed a 3D FDTD model to obtain the MW heating pattern of gels placed inside a domestic MW oven. Chen et al. (2007) simulated an industrial-scale MW sterilization system by a combination of EM and thermal models using the FDTD methods. Recently, the conformal FDTD technique is used in simulation models for moving packaged foods in continuous pilot-scale MW systems (Chen et al. 2008). In this chapter, we will provide a general overview of the above-mentioned methods to solve MW field equations and then present several case studies to illustrate the use of conformal FDTD method in studying electric field patterns and heating uniformity in food trays during MW sterilization in a pilotscale 915 MHz system.
6.2. EM Wave Equations 6.2.1. Maxwell’s Equations The theoretical foundation for EM wave propagation was described by Maxwell around 1873 by a set of vector equations based on results of various experiments and theoretical derivations conducted by numerous researchers (see also Chapter 7 of this book). These equations have either a differential or an integral form. The differential form is used to govern the relations and variations of the electric and magnetic field at any point any time. For the equations to be valid, it is assumed that the field vectors have continuous derivatives, and are singlevalued and continuous functions of time and space (Balanis 1989). To completely define an EM field, boundary conditions need to be incorporated to take discontinuous charges and currents along the interface between different media into consideration. The differential form of Maxwell’s equations is given in the following equations (Balanis 1989):
∇ × Ε = − μr μ 0
∂Η ∂t
∇ × H = σ E + εr ε0
∂E ∂t
(6.1) (6.2)
∇⋅D = q
(6.3)
∇⋅B = 0
(6.4)
where E is electric field vector (V/m), and H is magnetic field vector (A/m); D is electric flux density (C/m2), and D = εrε0E; B is magnetic flux density (Wb/m2), and B = μrμ0H; ε0 and εr denote the dielectric permittivity in free space and the value relative to free space, respectively; μ0 and μr denote the dielectric permeability in free space and relative value, respectively; and q is electric charge density per unit volume (coulombs/m3). εr and μr are vectors in general; they are reduced to scalar for isotropic substances. Equation 6.1 represents Faraday’s law, indicating that the circulation of electric field strength surrounded by a closed contour is determined by the rate of change of the magnetic flux density. Equation 6.2 is Ampere’s law, indicating that the circulation of magnetic field strength enclosed by a closed contour is equal to the net current through the surface. Equation 6.3 presents Gauss’s electric law, which states that net electric flux out of an enclose region is equal to the charges contained within the region. Equation 6.4 presents Gauss’s magnetic law, which requires that the net magnetic flux out of a region is zero.
6.2.2. Boundary Conditions The field discontinuities along the interface between two different media are expressed in field vectors. The boundary conditions can be derived from Gauss’s electric and magnetic law along the median interface: nˆ × ( E 2 − E1 ) = 0
(6.5)
nˆ × (H 2 − H1 ) = 0
(6.6)
nˆ ⋅ ( D2 − D1 ) = 0
(6.7)
nˆ ⋅ ( B2 − B1 ) = 0
(6.8)
Chapter 6
Computer Simulation for Microwave Heating
103
where nˆ is normal unit component of the interface, the subscripts 1 and 2 denote the regions of different media. Equations 6.5 and 6.6 state that the tangential components across an interface between two media are continuous for electrical field and magnetic field, respectively. Equations 6.7 and 6.8 show the continuity of normal component across the boundary for electric flux density and magnetic flux density, respectively. It should be noted that Equation 6.7 holds only if there is no impressed magnetic current density along the boundary, which is valid for MW heating of foods.
where f (x), g( y), and h(z) are functions to be determined from wave equations for specific boundary conditions. They represent the behavior of EM waves in each of the three directions. Here we will briefly discuss the solutions in three classical coordinate systems (rectangular, cylindrical, spherical system). Detailed procedures have been presented in numerous publications (e.g., Harrington 1961; Balanis 1989; Sadiku 2001).
6.3. Solutions to Maxwell’s Equations
E ( x, y, z ) = aˆ x E x ( x, y, z ) + aˆ y E y ( x, y, z ) + aˆ z Ez ( x, y, z )
6.3.1. Analytical Solutions Equations 6.1–6.4 are coupled partial differential equations with at least two unknown variables in each equation. To uncouple these equations, only one unknown variable can appear inside the equation, while the others need to be eliminated, leading to second-order partial differential equations. For sinusoidal time-varying field, Equations 6.1 and 6.2 can be written as (Balanis 1989): ∇ 2 E = −ω 2 με E + jωμσ E
(6.9)
∇ 2 H = −ω 2 με H + jωμσ H
(6.10)
and where σ is electrical conductivity for a lossy material. A complex variable γ is commonly used, referred to as the propagation constant: where γ 2 = jωμσ − ω 2 με , or simply γ = jβ + α . The EM fields can be obtained by solving wave Equations 6.9 and 6.10 with appropriate boundary conditions. One of the most popular methods to solve these equations is known as separation of variables (Wylie 1960; Hilderbrand 1962). With this method, the solution of a scalar function, for example, Ex(x, y, z) in Cartesian (rectangular) coordinate system, is assumed to be a multiplication of three different scalar functions each having only one independent variable. Therefore, the field component Ex(x, y, z) can be written in the following form: E x ( x, y, z ) = f ( x ) g ( y ) h ( z )
6.3.1.1. Rectangular Coordinate System In the rectangular coordinate system, a general solution for the electric field E can be written as:
(6.11)
(6.12)
where aˆ x , aˆ y , and aˆ z are unit vectors in x-, y-, and z-directions, respectively. Substituting Equation 6.12 into wave Equation 6.9, the general equation is reduced into three scalar equations that can be solved by using Equation 6.11 (separation of variables). Depending on the nature of the problem, different structures of the functions are used to represent distinct wave propagations. For example, standing waves are represented using sinusoidal functions while travelling waves are constructed by exponential functions. As an example, an EM wave is assumed to propagate inside a rectangular geometry, which has a rectangular cross-section with infinite length regarding the wave propagation direction. This is illustrated in Figure 6.1. By following the procedures of the separation of variable method, one can derive the electric field component Ex as: E x ( x, y, z ) = [ A1 cos (β x x ) + A2 sin (β x x )]
[ B1 cos (β y y ) + B2 sin (β y y )]
[C1e− jβ z + C2 e+ jβ z ] z
z
(6.13)
where A1, A2, B1, B2, C1, and C2 are constants and determined by applying appropriate boundary conditions. The waveguide is limited in x- and y-directions; the forms of the waves in these directions are described with sinusoidal functions. In z-direction, the EM wave propagates into infinity, producing traveling waves in both +z- and −z-directions. These
104
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
y y
ρ
b
ϕ x
a
z
a
x
Figure 6.1. Rectangular geometry for wave propagation.
are shown in Equation 6.13. For other components, due to the symmetric merits of Maxwell’s equations, the general solutions can be constructed similarly by applying the duality or reciprocity theorem mentioned above. 6.3.1.2. Cylindrical Coordinate System In cylindrical systems, solutions for Maxwell’s equations can be constructed as in the rectangular coordinate system; cylindrical coordinates, however, are more convenient. The general solution for a cylindrical coordinate system can be written as: E ( x, y, z ) = aˆ ρ Eρ ( x, y, z ) + aˆφ Eφ ( x, y, z ) + aˆ z Ez ( x, y, z )
(6.14)
where aˆ ρ , aˆφ , and aˆ z are unit vectors in cylindrical coordinates. Figure 6.2 shows a cylindrical coordinate system that has a circular cross-section in the x-y-plane and infinite length in z-direction. The general solution can be constructed by using the separation of variable method:
ψ ( ρ, φ , z ) = [ A1J m ( βρ ρ ) + A2Ym ( βρ ρ )]
[ B1 cos ( mφ ) + B2 sin ( mφ )]
[C1e− jβ z + C2 e+ jβ z ] z
z
(6.15)
z Figure 6.2. Cylindrical coordinate system.
where ψ ( ρ, φ, z ) is the solution for any field in the cylindrical coordinate system. J m ( β ρ ρ ) is the first Bessel function while Ym ( β ρ ρ ) is the second. A1, A2, B1, B2, C1, and C2 are constants and are determined by applying appropriate boundary conditions. In cylindrical coordinate systems, J m ( β ρ ρ ) and Ym ( β ρ ρ ) represent standing waves. Therefore, Equation 6.15 indicates a general field solution for an EM wave that is limited by a cylindrical waveguide and propagates into infinity in z-direction. For most radiation problems, it is required to calculate the field patterns outside the cylinder. For these cases, the first and second kind of Bessel functions is replaced by Hankel function, which represents a traveling wave. Its solution is shown in the following equation:
ψ ( ρ, φ, z ) = [ A1 H m(1) ( β ρ ρ ) + A2 H m(2) ( β ρ ρ )]
[ B1 cos (mφ ) + B2 sin (mφ )]
[C1e− jβ z + C2 e+ jβ z ] z
z
(6.16)
6.3.1.3. Spherical Coordinate System The spherical coordinates are desirable when a spherical geometry is involved in computing the EM field. The spherical coordinate system is shown in the Figure 6.3:
Chapter 6
Computer Simulation for Microwave Heating
105
6.3.2. Numerical Solutions for EM Fields
Ψ ϕ
r
Figure 6.3. Spherical coordinate system.
The general solutions are obtained by solving the following vector wave equations in the spherical coordinate system. E (r , ϕ , ψ ) = aˆr Er (r , ϕ , ψ ) + aˆϕ Eϕ (r , ϕ , ψ ) + aˆψ Eψ (r , ϕ , ψ )
(6.17)
Similar to the solution of the rectangular and the cylindrical coordinate system, the wave Equation 6.17 is solved by using the separation of variable technique. E (r , ϕ , ψ ) = [ A1 jn (β r ) + A2 yn (β r )]
[ B1 Pnm (cos ψ ) + B2Qnm (cos ψ )] [C1 cos (mϕ ) + C2 sin (mϕ )]
(6.18)
where jn(βr) and yn(βr), which indicate the standing wave along the radius direction, are spherical Bessel functions of the first and second kind, respectively. Pnm and Qnm are referred to as the associated Legendre functions of the first and second kind, respectively. A1, A2, B1, B2, C1, and C2 are constants to be determined by appropriate boundary conditions. For the traveling wave outside the sphere along the radius, jn(βr) and yn(βr) are replaced by Hankel functions of the first and second kind, hn(1) (βr ) and hn(2) (βr ) , respectively.
For complex geometries, there is no closed-form solutions. Numerical methods are used to provide approximate solutions. The fundamental concept of numerically solving complex equations such as Maxwell’s equations and thermal equations is to discretize the geometry of interest into numerous cells with specified cell sizes. The numerical approach employs linear or polynomial approximations for each cell, thus reducing complex partial differential equations to sets of simple linear or polynomial equations. Starting from the mid-1960s, considerable efforts have been made to numerically solve practical EM-related problems by taking advantage of modern powerful computers (Sadiku 2001). The following sections describe briefly the most commonly used numerical methods to solve Maxwell’s field equations. Those methods are the Finite Difference Method (FDM), the MoM, and the FEM. 6.3.2.1. FDM The FDM was first developed by Thom (Thom and Apelt 1961) to solve hydrodynamic problems. This technique uses finite difference approximations in algebraic form to replace the differential equations and calculate the value of the dependent variable at one point based on those values at its neighboring points. Basically, the FDM follows the following three steps to obtain the numerical solutions: • Discretize the geometry into numerical grid lines with specified cell size. • Replace the differential equations with finite difference equations by appropriate approximations in their algebraic form. • Solve the linear equations along with boundary and initial conditions. Detailed procedures are slightly different depending on the nature of the problems, the solution regions, as well as boundary conditions. For EM-related problems, the finite difference technique was deployed to solve the time differentiated Maxwell’s curl equations (Yee 1966; Taflove and Brodwin 1975a, 1975b; Taflove 1980; Taflove and Umashankar
106
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
1980, 1981, 1990; Jurgens et al. 1992; Okoniewski 1993). Thus, this technique is usually called FDTD. In brief, FDTD method is a time-marching procedure that simulates the continuous EM waves in a finite spatial region while continuously time-stepping until the desired simulation time is achieved or a stable field pattern is established (Taflove 1998). Obviously, only finite computational grids can be practically applied, although the modeled region extends theoretically to infinity. As a result, absorbing boundary conditions (ABC) are employed to terminate the computational grids that permit all the outgoing waves to propagate into infinity with negligible reflections. Another factor to be considered in employing FDTD technique is to ensure the simulation accuracy by well-resolved spatial and temporal variations using time- and space-sampling process. The sampling in space is determined by following the Nyquist theorem that requires at least 10 cells per wavelength. The sampling in time depends on the selection of spatial sampling size to ensure the overall stability of the algorithm. Yee Algorithm Kane Yee in 1966 developed an effective FDTD algorithm to simulate wave propagations inside a lossless material by solving a set of finite-difference equations for the time-dependent Maxwell’s curl equations. The Yee algorithm simultaneously calculates the coupled E and H fields. Using the Yee algorithm in a 3D network, the E component in each direction is surrounded by four H components of its vertical counterpart, while each H component is surrounded by four E components in a similar fashion. The interlinked E and H field components intrinsically keep the validity of Faraday’s and Ampere’s Laws. The algorithm naturally maintains the continuity of the tangential E and H fields across the interfaces of distinct media, requiring no extra efforts to satisfy the boundary conditions along the interfaces. The explicit secondorder central-difference equations are employed in Yee algorithm, which intuitively guarantees the two Gauss’s Law relations. The Yee algorithm calculates all E field components based on the latest H fields and stores the values in the internal memory at a particular simulation time step, and then calculates
all H field components from the newly obtained E fields. The computation continues until the required simulation time is reached. The above strategy eliminates the matrix inversion that requires lengthy computation time and large computer memory. It also naturally simulates a wave propagation without spurious decay due to artificial nonphysical wave that resulted from the algorithm. For the sake of illustration, 1D FDTD algorithms are presented here. A 3D problem is discussed in more details in the case study. Figure 6.4 shows how the FDTD simulation approaches in time (t) and space (x). The EM wave is propagated into x-direction, while only Ey and Hz are assumed to exist according to the Right Thumb Rule. For the 1D wave propagation problem shown in Figure 6.4, the Maxwell’s equations are reduced to (Taflove 1998): ∂E y 1 ⎛ ∂H z ⎞ = ⎜− − σ Ey ⎟ ⎠ ∂t ε ⎝ ∂x
(6.19)
∂H z 1 ⎛ ∂E y ⎞ = ⎜− − ρ′Hz ⎟ ⎠ ∂t μ ⎝ ∂x
(6.20)
where μ and ε are permeability and permittivity, respectively; σ is the electrical conductivity; and ρ′ is denoted as magnetic loss, which are set to 0 for simplification. The latter assumption is applicable to food applications. Equations 6.19 and 6.20 denote an EM wave propagating in TE mode, indicating that the electrical field is vertical to the wave propagation direction. The finite difference form for Equation 6.19 is obtained using the approximation: E yn +1 [iΔx ] − E yn [iΔx ] Δt ⎞ ⎛ H zn +1 / 2 [(i + 1 / 2 ) Δx ] − ⎜ n +1 / 2 H 1 [(i − 1 / 2 ) Δx ] − σ E n +1/ 2 iΔx ⎟⎟ = ⎜− z [ ] y ε⎜ Δx ⎟ ⎟ ⎜ ⎠ ⎝ (6.21) where Δx is the space resolution, i is the spatial index, and n is the time step. Here n + 1/2 is used because Hz is placed half-time step delayed from the
Chapter 6
Computer Simulation for Microwave Heating
107
t E
E
E
E
E
E
E
3Δt H
5/2Δt
H
E
E
H E
H E
H E
H E
E
2Δt H
3/2Δt
H
E
E
H E
H E
H E
H E
E
1Δt
1/2Δt E 0
H 1/2Δx
H H H H H 5/2Δx 7/2Δx 9/2Δt 11/2Δx 3/2Δx E E E E E E Δx
2Δx
3Δx
4Δx
5Δx
6Δx
x
Figure 6.4. E and H field arrangement of FDTD algorithm for one-dimensional wave propagation using central difference time-stepping procedures.
corresponding Ey from Figure 6.4. The term E yn+1/ 2 is estimated using a semi-implicit approximation: E yn+1 / 2 =
E yn+1 + E yn 2
(6.22)
step n – 1/2 and n + 1/2 is stored in the memory available for computation. As a result, to estimate the magnetic field Hz used in Equation 6.20, a semiimplicit approximation is employed: H zn =
Rearrange Equation 6.21 with Equation 6.22 and remove Δx for simplification: Δt ⎛ 1 − σΔt ⎞ ⎟ n ⎜ ε ε 2 n +1 E y [i ] = ⎜ E [i ] − Δx σΔt σΔt ⎟ y 1+ ⎟ ⎜⎝ 1 + 2ε ⎠ 2ε n +1 / 2 n +1 / 2 {H z [i + 1 / 2 ] − H z [i − 1 / 2 ]} (6.23) Similar procedures are followed to compute for Hz in Equation 6.20, except that Hz at time step n exists due to magnetic loss. From Figure 6.4, the magnetic field Hz is supposed to be placed half a time step away from the electrical field so that only Hz at time
H zn+1 / 2 + H zn−1 / 2 2
(6.24)
With Equation 6.23, we obtain the explicit finite difference equation for Hz.
H
n +1 / 2 z
⎛ 1 − ρ ′Δt ⎞ ⎜ 2μ ⎟ [i ] = ⎜ ρ ′Δt ⎟ H zn −1/ 2 ⎟ ⎜1+ ⎝ 2μ ⎠ Δt μΔx − {E n [i + 1] − Eyn [i ]} ρ ′Δt y 1+ 2μ
(6.25)
108
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Equations 6.23 and 6.25 can be conveniently programmed for E and H field calculation.
f ( x i + Δx , t n ) = f ( x i , t n )
Numerical Dispersion Numerical dispersion is unavoidable whenever a numerical approach is used to solve the continuous wave equation. Numerical dispersion is defined as the variation of numerical wavelength with frequency f since the wavelength is represented in terms of cell size. In this section, the 1D scalar wave equation is obtained first, followed by an asymptotic study for numerical accuracy. For simplification, assuming the nonexistence of electric and magnetic loss, decoupling the Ey and Hz in Equations 6.19 and 6.20, and the second-order partial differential equation is obtained as: ∂ 2 H z ∂ ⎛ ∂H z ⎞ ∂ ⎛ 1 ∂E y ⎞ 1 ∂ Ey = ⎜ = ⎜− =− ⎟ ⎟ 2 ∂t ∂t ⎝ ∂t ⎠ ∂t ⎝ μ ∂x ⎠ μ ∂t ∂x (6.26) 2
Similarly, according to Equation 6.19, with the assumption of σ = 0: ∂2 Ey 1 ∂2 H z =− ∂ t∂ x ε ∂x 2
(6.27)
Combining Equations 6.26 and 6.27 yields: ∂2 H z 1 ∂2 H z ∂2 H z = = u2 2 2 με ∂x ∂t ∂x 2
(6.28)
where u = 1/ με is the speed of light inside the material under consideration. Equation 6.28 is a 1D scalar wave equation for Hz. Following similar procedures, wave equations for Ey are obtained as: 2 ∂2 Ey 2 ∂ Ey = u ∂t 2 ∂x 2
(6.29)
Obviously, both Ey and Hz vary as the same function of time and space. The solution of one field component leads to another. From now on, we replace Ey and Hz with a more general function f (x, t). The solution for f leads to both solutions for Ey and Hz. In Yee’s algorithm, the partial differential equations in Equations 6.28 and 6.29 are differentiated using second-order central difference equations. In detail, by Taylor ’s expansion, at space point xi with space increment Δx and fixed time point tn:
∂ f ( x i , t n ) ( Δx ) ∂ f 2 ( x i , t n ) 2 + + O ⎡⎣( Δx ) ⎤⎦ ∂x 2 ∂x 2 (6.30) 2
+ Δx
f ( x i − Δx , t n ) = f ( x i , t n ) ∂ f ( x i , t n ) ( Δx ) ∂ f 2 ( x i , t n ) 2 + + O ⎡⎣( Δx ) ⎤⎦ 2 ∂x 2 ∂x (6.31) 2
− Δx
2 where O ⎡⎣( Δx ) ⎤⎦ is a notation for the remaining higher order terms that approach to zero much faster than the lower order of Δx. Combining Equations 6.30 and 6.31,
f ( xi + Δx, t n ) + f ( xi − Δx, t n ) = 2 f ( xi , t n ) + ( Δx )
2
∂f 2 ( xi , t n ) 2 + O ⎡⎣( Δx ) ⎤⎦ (6.32) 2 ∂x
2 with Δx small enough, O ⎡⎣( Δx ) ⎤⎦ can be neglected without significant loss of accuracy. Therefore, the second-order partial differential equation can be represented as:
∂f 2 ( xi , t n ) ∂x 2 f ( xi + Δx, t n ) + f ( xi − Δx, t n ) − 2 f ( xi , t n ) (6.33) = (Δx )2 Similarly, the second-order partial derivatives with respect to time are obtained as: ∂f 2 ( x i , t n ) ∂t 2 f ( xi , t n + Δt ) + f ( xi , t n − Δt ) − 2 f ( xi , t n ) (6.34) = ( Δt )2 For simplification, we write f ( xi , t n ) = fi n , xi +1 = xi + Δx and t n+1 = xn + Δt . With these shorthand notations, combining Equations 6.33 and 6.34, the wave equations in Equations 6.28 and 6.29 can be reduced to: fi n+1 + fi n−1 − 2 fi n fn + fn −2fn = u2 i +1 i −1 2 i 2 (Δt ) (Δx )
(6.35)
Rearranging the terms in Equation 6.35 to obtain the explicit expression of the latest value at a specified
Chapter 6
space point based on its previous value, the current value and the values of the neighboring points: ⎛ uΔt 2 ⎞ n fi n+1 = ⎜ ( fi+1 + fi−n1 − 2 fi n ) + 2 fi n − fi n−1 ⎝ Δx ⎟⎠
(6.36)
Equation 6.36 is the numerical dispersion relationship of the finite difference estimation for 1D scalar wave equation (Taflove 1998). It uses the current and previous values stored in the computer memory to calculate the latest value. For example, when evaluating the sinusoidal traveling wave in a 1D finite difference scheme: fi n = e j (ωΔt − k1Δx )
(6.37)
where ω = 2π f is the angular frequency; k1 is a numerical wave number that differs from the continuous wave number k = ω/u due to the numerical approximations. This can be observed by substituting Equation 6.37 into Equation 6.36 and factoring out the common terms on both sides of the resulting equation. Finally, the implicit form of the dispersion relation is obtained as (Taflove 1998): e jωΔt + e − jωΔt ⎛ uΔt ⎞ ⎛ e jk1Δx + e − jk1Δx ⎞ =⎜ − 1⎟ + 1 (6.38) ⎝ Δx ⎟⎠ ⎜⎝ ⎠ 2 2 2
By using Euler identity, Equation 6.38 can be reduced to: ⎛ uΔt ⎞ cos(ωΔt ) = ⎜ [cos(k1Δx ) − 1] + 1 (6.39) ⎝ Δx ⎟⎠ 2
The difference between k1 and k results in the numerical errors, which we need to depress to develop a reliable simulation algorithm. Based on Equation 6.39, two cases will be considered: (a) Δt → 0, Δx → 0: For very small arguments, one-term Taylor ’s series is applied to approximate the cosine functions in Equation 6.39: (ωΔt )2 ⎛ uΔt ⎞ 1− =⎜ ⎝ Δx ⎟⎠ 2
2
⎡ ( k1Δx )2 ⎤ − 1⎥ + 1 (6.40) ⎢1 − 2 ⎣ ⎦
Simplifying Equation 6.40 leads to k = ω / u . This is equal to the continuous wave number. Therefore, when the time and space increment
Computer Simulation for Microwave Heating
109
approach zero, the numerical results converge to the analytical solutions. (b) uΔt = Δx : This is another special case, by which Equation 6.40 again is reduced to k = ω / u. While the two special cases are considered above, the general formulation for the numerical wave number is k1 =
⎧ ⎛ Δx ⎞ 2 ⎫ 1 cos −1⎨⎜ ⎟⎠ [ cos(ωΔt ) − 1] + 1⎬ ⎝ Δx Δ u t ⎩ ⎭
(6.41)
Equation 6.41 can be used to analyze the numerical error due to finite differences by solving the numerical wave number with indistinct cell sizes in terms of the wavelength. For example, with cell size Δx = λ0/10 and Δt = Δx/2u, Equation 6.41 leads to k = 0.636 / Δx . Following the similar definition to the analog-phase velocity of the continuous wave equation as vp = ω/k, where vp is defined as phase velocity for the continuous wave equation, the numerical phase velocity is denoted as v p = ω / k . Therefore with the previous case, v p = 0.9873u, indicating that for a continuous wave propagating into 10λ0, the simulated numerical wave only propagates over a distance of 9.873λ0. This discrepancy results in a phase error of 45.72. When the cell size is reduced to Δx = λ 0 /20, the phase velocity is changed to be 0.997u. Accordingly, the phase error is reduced by three quarters to 10.8. Numerical Stability One convenient method to analyze the numerical stability is to use the Eigenvalue method, which separates the space and time derivative part of the original wave equation for analysis purposes. By setting the stable range for the complete spectrum of spatial Eigenvalues, it is guaranteed that all possible numerical modes in the grid are stable. The detailed procedure for Eigenvalue problems is presented in the following equations: ∂2 n fi = Πfi n ∂t 2
(6.42)
where Π is denoted as the operator of second-order time derivatives for a wave function. Combining the left side of Equation 6.35 and right side of Equation 6.42:
110
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
fi n+1 + fi n−1 − 2 fi n = Πfi n 2 Δ t ( )
(6.43)
The numerical stability requires that the absolute value of fi n+1 fi n is less than one for all possible wave propagation modes. To take this requirement into consideration, rearranging Equation 6.43 yields: 2
n +1 ⎞ ⎛ fi n+1 ⎞ 2 ⎛ fi ⎡ ⎤ 2 Π Δ t − + ( ) ⎜⎝ f n ⎟⎠ ⎣ ⎦ ⎜⎝ f n ⎟⎠ + 1 = 0 i i
(6.44)
Solving the Equation 6.44 gives: 2
2 2 fi n+1 ⎡⎣2 + Π ( Δt ) ⎤⎦ ± ⎡⎣2 + Π ( Δt ) ⎤⎦ − 4 = 2 fi n
To guarantee
(6.45)
fi n+1 fi n ≤ 1 , we need to have
2
⎡⎣2 + Π ( Δt )2 ⎤⎦ − 4 ≤ 0 , which reduces to: −4 ≤Π≤0 (Δt )2
(6.46)
Following the similar procedure, the Eigenvalue Π can be limited by the spatial resolution: −4u2 ≤Π≤0 (Δx )2
has the capability of being implemented in generic computer programs for broad range applications such as waveguide problems, and absorption of EM energy by biological bodies (Sadiku 2001). Basically four main steps are involved in the FEM: • Divide the solution region into multiple subregions or elements. • Obtain the partial differential equation in each element. • Integrate the solutions of all subregions into the solution for the entire solution space. • Solve the obtained linear equations. These procedures are illustrated in Figure 6.5. Usually, in FEM method, the computational domain is divided into numerous elements, each having a triangular or other simple shape. For each element, there are three zeniths, which are indexed by integer numbers. To illustrate the principle of FEM, we calculate the potential distribution inside the irregular geometry shown in Figure 6.5. Basically, the potential in each triangular element is assumed to be constant Ve and the overall distribution of the potential is assumed equal to the sum of the potential in each element. N
(6.47)
V ( x, y ) ≈ ∑ Ve ( x, y )
For any spatial grid inside the computational domain, to ensure the numerical stability requires that the Eigenvalues of the spatial mode fall completely into the range of the Eigenvalues based on the timestepping equations, that is, Equation 6.47 should be completely contained inside Equation 6.46. For this reason, the time step can be limited by a predetermined cell size Δx. Δt ≤
Δx c
(6.49)
e =1
3
2
6.3.2.2. FEM Another popular method to numerically solve EM problems is the FEM. This method is powerful for very complex geometries. The FEM
1
2 1
1
1
3
3 8
7
1
1
2
3
1
3 3 2
9
4
2
8
(6.48)
Equation 6.48 gives the limits for the time increment selection for the 1D scalar wave equation. The extension of Equation 6.48 to 2D and 3D problems is straightforward (Taflove 1998).
3
2
1 1 1
2 3 6
5
2 3
4 2 3
2
7 Figure 6.5. FEM discretization for irregular geometry.
6
5
Chapter 6
where N is the number of elements, V(x,y) is the desired potential distribution. Since the element is triangular, Ve(x,y) is represented by a linear equation with three constants to be determined (Sadiku 2001). Ve ( x, y ) = a + bx + cy
(6.50)
where a, b, and c are constants calculated from the potentials at each zenith. From Equation 6.50, we denote the potential at zenith i as Vei (i = 1, 2, 3), the value of a, b, and c can be computed using matrix manipulation: ⎡ a ⎤ ⎡1 x1 ⎢ b ⎥ = ⎢1 x 2 ⎢ ⎥ ⎢ ⎢⎣ c ⎥⎦ ⎢⎣1 x3
y1 ⎤ y2 ⎥ ⎥ y3 ⎥⎦
−1
⎡Ve1 ⎤ ⎢V ⎥ ⎢ e2 ⎥ ⎢⎣Ve3 ⎥⎦
(6.51)
Combining Equations 6.50 and 6.51, the potential at any point in the element is obtained as: Ve ( x, y ) − [1 x
⎡1 x1 y ] ⎢1 x2 ⎢ ⎢⎣1 x3
y1 ⎤ y2 ⎥ ⎥ y3 ⎥⎦
−1
⎡Ve1 ⎤ ⎢V ⎥ ⎢ e2 ⎥ ⎢⎣Ve3 ⎥⎦
(6.52)
Having considered the potential in each element, the potential distribution is obtained by assembling all elements in the solution region. The detailed procedures are documented in numerous publications. The equations involved are listed in this section: W=
1 T ε [V ] [C ][V ] 2
(6.53)
where W is the energy associated with the solution region, and ε is dielectric permittivity.
[V ] = [V1 V2 … Vn ]T ⎡C11 ⎢C ⎢ 21 ⎢C31 ⎢ ⎢C41 [C ] = ⎢C51 ⎢ ⎢C61 ⎢C71 ⎢ ⎢C81 ⎢C ⎣ 91
C12 C22 C32 C42 C52 C62 C72 C82 C92
C13 C23 C33 C43 C53 C63 C73 C83 C93
C14 C24 C34 C44 C54 C64 C74 C84 C94
C15 C25 C35 C45 C55 C65 C75 C85 C95
C16 C26 C36 C46 C56 C66 C76 C86 C96
C17 C27 C37 C47 C57 C67 C77 C87 C97
(6.54) C18 C19 ⎤ C28 C29 ⎥ ⎥ C38 C39 ⎥ ⎥ C48 C49 ⎥ C58 C59 ⎥ ⎥ C68 C69 ⎥ C78 C79 ⎥ ⎥ C88 C89 ⎥ C98 C99 ⎥⎦ (6.55)
Computer Simulation for Microwave Heating
111
where [C] is a global coefficient matrix that has each element denoting the coupling between different nodes, that is, Cij is the coupling between node i and j. The Cij is calculated based on the continuity of the potential distribution across the boundary of neighboring elements. For example, to calculate C12 in Figure 6.5, there are totally nine global nodes and eight elements to represent the solution region. Each element has three local nodes indexed in counterclockwise direction. [1] [2 ] C12 = C13 + C23
(6.56)
[1] 13
where C is the coupling coefficient between local [2 ] nodes 1 and 3 in local element 1. C23 is the coupling efficient between local nodes 2 and 3 in local element 2. Having obtained the global coefficient matrix from Equation 6.56, physical conditions are applied in Equation 6.53 to solve the desired potential. For example, to solve the Laplace’s equation, we require that the associated energy W be minimum. Therefore, the first partial derivatives of W are set to zero: ∂W ∂W ∂W = == =0 ∂V1 ∂V2 ∂Vn
(6.57)
Substituting Equation 6.53 into Equation 6.57, we obtain a set of linear equations. These equations are then solved by several popular methods such as iteration method and band matrix method (Sadiku 2001). FEM has been applied to solve a wide range of problems due to its capability for handling complex geometry and relative easy extension for general purposes. However, there are several disadvantages associated with this method, including intensive memory usage for matrix inversion as well as tedious data preprocessing. 6.3.2.3. MOM The MoM is another popular numerical approach applied to a wide range of EM problems. This method takes moments with corresponding weighing functions, discretizes the differential or integral equations for each of these moments, and solves the obtained matrix for parameters of interest (Harrington 1967, 1968, 1992). A detailed description of the MoM technique can be found in Richmond (1965), Mittra (1973), Tsai
112
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
(1978), and Jurgens et al. (1992). Here we only briefly present some of the main procedures. For illustration purposes, we use the MoM technique to calculate the dissipated power of EM radiation. The primary concern of the product’s response to an EM field is the specific absorption rate (SAR) defined as: SAR =
σ E ρ
2
(6.58)
where σ is the electrical conductivity, ρ is the mass density, and E is the electric field inside a product (Kastner and Mittra 1983). According to Equation 6.58, the SAR can be calculated from the value of electric field E. The electric field E, on the other hand, can be derived by representing Maxwell’s curl equations using a tensor integral equation (TIE) (Livesay and Chen 1974; Kong 1981). Following the procedures developed by Livesay and Chen (1974), the solution of E is obtained as: E (r ) = − jωμ0 ∫ G0 (r , r ′ ) ⋅ J eq (r ′ ) dv ′
(6.59)
where G0(r, r′ ) is free-space Green’s function, indicating the electrical field at a space point r due to an infinitesimal source at space point r′. Jeq(r′ ) is the equivalent current density, which is a singular function in each direction: J eq (r , r ′ ) = δ (r − r ′ )
(6.60)
The TIE is then obtained as: PV E (r ) = χ (r ) 1+ 3 jωε 0
The electric field E is then determined from Equation 6.62 as:
[ E ] = − [G ]−1 [ E i ]
(6.63)
A computer program was developed by Guru and Chen (1976) to compute the SAR inside a biological body using MoM following Equations 6.58 to 6.63. It is obvious from Equation 6.63 that matrix inversion, elimination, and iteration are involved in the computation. This usually requires significant computer memory and lengthy computation times as does the FEM method. For these reasons, the application of MoM is limited to solve the problems with scattering and irradiating geometries that are electrically large, in the order of λ3.
6.4. MW Heating Equations 6.4.1. Dissipated Power in Dielectric Materials For MW heating applications, the EM power is dissipated inside the dielectric material to heat the product. Therefore, it is necessary to calculate dissipated MW power associated with EM waves. This can be derived from the time-averaged Poynting vector over one period (Balanis 1989): 1 ψ av = Re [ E × H* ] 2
(6.64)
By taking the volume integral and applying the divergence theorem, the dissipated real power is achieved as:
∫ χ (r ′ ) E (r ) v
E (r ) ⋅ G (r , r ′ ) dv ′ + χ (r ) 1+ 3 jωε 0
Pd =
i
(6.61)
where PV is the principal value (Sadiku 2001), Ei(r) is the incident electrical field, which is already known. E(r) is the electrical field to be determined by MoM. Equation 6.61 can be written in a matrix form, suitable for programming.
[G ][ E ] = − [ E i ]
(6.62)
1 2 σ E dv 2 ∫∫∫V
(6.65)
where Pd is EM power dissipated inside a volume V. σ denotes electrical conductivity of the media inside a volume V. Once the power dissipation is calculated, it is then used as a source for heating the product.
6.4.2. Heat Transfer Equations For MW heating applications, it is desirable to obtain information on the temperature changes in
Chapter 6
response to the dissipated MW power. The temperature profile can be determined by applying the energy conservation requirement on a differential control volume (Incropera and DeWitt 2001). The law of energy conservation states that for a unit volume in the medium, the rate of energy transfer by conduction or convection plus the volumetric rate of thermal energy generation must be equal to the rate of change of thermal energy stored within the volume. For solid foods, this can be expressed in the following equation:
ρc p
∂T = ∇ ( K (T ) ⋅∇T ) + q ∂t
(6.66)
where ρ is the mass density (kg/m3), cp is the specific heat capacity (J/kg · K), q is power density (J/m3s or W/m3), and K(T) is thermal conductivity (W/m · K). For MW heating, q is provided by the dissipated MW power. Temperature distribution can be determined by solving Equation 6.66 with appropriate boundary and initial conditions. Three types of boundary conditions are encountered in heat transfer Equation 6.66: the Dirichlet condition, the Neumann condition, and the Convective surface condition. The Dirichlet condition corresponds to a situation that the surface is maintained at a fixed temperature Ts; the Neumann condition requires that the heat flux on the boundary be fixed; and the Convective surface condition is obtained by exchanging thermal energy between different mediums (Incropera and DeWitt 2001).
Computer Simulation for Microwave Heating
113
to reading errors. Special measures need to be taken to reduce the interference. Fiber-optic temperature sensors, on the other hand, do not interfere with EM waves, and thus they serve as a reliable means for direct temperature measurement of selected locations during MW heating. Several methods have been used to determine MW heating patterns (see also Chapter 7 of this book). These methods include infrared imaging and chemical marker methods. Infrared cameras provide direct temperature information for the surface or a cut surface of a food package after heating processes. But it is difficult to use this method to obtain temperature profile inside food packages during a heating process. Chemical marker methods, on the other hand, provide information on heating patterns based on formation of new chemical compounds during complete heating processes. For example, one chemical marker method measures color changes as a result of formation of chemical compound (M-2) due to Maillard reaction between amino acids and a reducing sugar, ribose in food matrices. The color response depends upon heat intensity at temperatures beyond 100°C and, therefore, serves as an indirect indicator of temperature distribution during MW heating for food sterilization that calls for product temperature to be above 100°C. Detailed information about the kinetics of Marker-2 formation with temperature could be found elsewhere (Kim and Taub 1993, Lau et al. 2003; Pandit et al. 2006).
6.4.3. Measurement of Temperature Responses
6.5. Computer Simulation of MW Heating
Direct or indirect means for temperature measurement are used to validate computer simulation models. Temperature can be directly measured by numerous electronic sensors such as resistance temperature detectors (RTDs), thermistors, and thermocouples. Of all these methods, thermocouples are widely used to monitor processing temperatures (Desmarais and Breuereis 2001). But when exposed to a high EM field, the metal parts of the electronic sensors may cause EM interference (EMI) leading
We have discussed analytical and numerical solutions to EM field equations applied to solve industrial MW heating problems. A particular challenge to numerically simulate complicated MW heating process is to concurrently calculate EM and thermal field with temperature-dependent dielectric properties. This section describes the use of the conformal FDTD method in the development of a computer simulation model for coupled EM and heat transfer within a food package during MW heating in a
114
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Ey
915 MHz water emersion MW sterilization system. A detailed description of this system is presented in Section 6.6. We first describe equation formulation, step-by-step validation for simple cases with analytical solutions, followed by experimental validation for a complicated system, and finally the applications of the model for optimization of the system process parameter to achieve desirable heating uniformity.
z
Hz Ez
Ex
Ez
6.5.1. Model Formulation Using the FDTD Method
Hy Ez Ey
Hx
(i, j, k)
∂H x 1 ⎛ ∂E y ∂E z ⎞ = ⎜ − ∂t μ t ⎝ ∂z ∂y ⎟⎠
(6.67)
∂H y 1 = ∂t μt
⎛ ∂E z ∂E x ⎞ − ⎜⎝ ⎟ ∂x ∂z ⎠
(6.68)
∂H z 1 ⎛ ∂E x ∂E y ⎞ = ⎜ − ∂t μ t ⎝ ∂y ∂x ⎟⎠
(6.69)
∂E x 1 ⎛ ∂H z ∂H y ⎞ = ⎜ − − σ t Ex ⎟ ⎠ ∂t ε t ⎝ ∂y ∂z
(6.70)
∂E y 1 ⎛ ∂Hx ∂H z ⎞ = ⎜ − − σ t Ey ⎟ ⎝ ⎠ ε t ∂z ∂t ∂x
(6.71)
∂E z 1 ⎛ ∂H z ∂H x ⎞ = ⎜ − − σ t Ez ⎟ ⎠ ∂t ∂y ε t ⎝ ∂x
(6.72)
Ez
Ey Hy
Ex
Hz
Ex
The Maxwell’s equations in a 3D rectangular coordinate system can be presented in a time harmonic form (Taflove 1998):
Ex
Hx
Ey y
x Figure 6.6. Layout of field components for FDTD algorithm.
In space, a grid point can be expressed as: (i, j, k ) = (i ∗ δ x, j ∗ δ y, k ∗ δ z )
(6.73)
where δ x, δ y, and δ z are the cell sizes in x-, y-, and z-direction, respectively. For a function having space and time dependence, it can be expressed as: g( x, y, z, t ) = g(i ∗ δ x, j ∗ δ y, k ∗ δ z, n ∗ δ t )
where μt , ε t , and σ t denote dielectric permeability, permittivity, and conductivity, respectively. The subscripts t emphasize that these constitutive parameters inside a food are dependent of temperature and thus heating time. To numerically solve Equations 6.67–6.72, we use the Yee’s method to discretize the computational region into unit cells and estimate the derivatives by second-order central finite-difference approximation. To achieve second-order accuracy, electrical field component and magnetic field component are placed half cell size away from each other, as shown in Figure 6.6.
= g n (i, j, k )
(6.74)
where g( x, y, z, t ) is a generic function and δ t is a time step. From these notations, the second-order central finite-difference forms for Equations 6.67–6.72 are derived to be suitable for computer programming (Taflove and Brodwin 1975a, 1975b; Lau and Sheppard 1986). H xn+1 / 2 (i, j + 1 / 2, k + 1 / 2) = H xn−1 / 2 (i, j + 1 / 2, k + 1 / 2) +
δt μ ∗ δ i , j +1 / 2,k +1 / 2
⎡ E (i, j + 1 / 2, k + 1) − E (i, j + 1 / 2, k ) ⎤ ⎥ ⎢ n n ⎣ + Ez (i, j, k + 1 / 2) − Ez (i, j + 1, k + 1 / 2) ⎦ n y
n y
(6.75)
Chapter 6
H yn+1 / 2 (i + 1 / 2, j, k + 1 / 2) = H yn−1 / 2 (i + 1 / 2, j, k + 1 / 2) +
δt μ * δ i +1 / 2, j ,k +1 / 2
⎡ E (i + 1, j, k + 1 / 2) − E (i, j, k + 1 / 2) ⎤ ⎢ n ⎥ n ⎣ + E x (i + 1 / 2, j, k ) − E x (i + 1 / 2, j, k + 1) ⎦ n z
n z
(6.76)
H zn+1 / 2 (i + 1 / 2, j + 1 / 2, k ) = H zn−1 / 2 (i + 1 / 2, j + 1 / 2, k ) +
δt μ ∗ δ i +1 / 2, j +1 / 2,k
⎡ E (i + 1 / 2, j + 1, k ) − E (i + 1 / 2, j, k ) ⎤ ⎥ ⎢ n n ⎣ + E y (i, j + 1 / 2, k ) − E y (i + 1, j + 1 / 2, k ) ⎦ n x
n x
(6.77)
⎛ σ i +1 / 2, j ,k δ t ⎞ n E xn+1 (i + 1 / 2, j, k ) = ⎜ 1 − E x (i + 1 / 2, j, k ) ε i +1 / 2, j ,k ⎟⎠ ⎝
+
δt ε i +1 / 2, j ,k ∗ δ i +1 / 2, j ,k
⎡ H zn+1 / 2 (i + 1 / 2, j + 1 / 2, k ) ⎤ ⎥ ⎢ n +1 / 2 ⎢ − H z (i + 1 / 2, j − 1 / 2, k ) ⎥ ⎢ + H yn+1 / 2 (i + 1 / 2, j, k − 1 / 2) ⎥ ⎥ ⎢ ⎢⎣ − H yn+1 / 2 (i + 1 / 2, j, k + 1 / 2) ⎥⎦ (6.78)
⎛ σ i , j +1 / 2,k δ t ⎞ n E yn+1 (i, j + 1 / 2, k ) = ⎜ 1 − E y (i, j + 1 / 2, k ) ε i , j +1 / 2,k ⎟⎠ ⎝
+
δt ε i , j +1 / 2,k * δ i , j +1 / 2,k
⎡ H xn+1 / 2 (i, j + 1 / 2, k + 1 / 2) ⎤ ⎢ ⎥ n +1 / 2 ⎢ − H x (i, j + 1 / 2, k − 1 / 2) ⎥ ⎢ + H zn+1 / 2 (i − 1 / 2, j + 1 / 2, k ) ⎥ ⎢ ⎥ ⎢⎣ − H zn+1 / 2 (i + 1 / 2, j + 1 / 2, k ) ⎥⎦ (6.79)
⎛ σ i , j ,k +1 / 2δ t ⎞ n Ezn+1 (i, j, k + 1 / 2) = ⎜ 1 − Ez (i, j, k + 1 / 2) ε i , j ,k +1 / 2 ⎟⎠ ⎝
+
δt ε i , j ,k +1 / 2 ∗ δ i , j ,k +1 / 2
⎡ H yn+1 / 2 (i + 1 / 2, j, k + 1 / 2) ⎤ ⎥ ⎢ n +1 / 2 ⎢ − H y (i − 1 / 2, j, k + 1 / 2) ⎥ ⎢ + H n+1 / 2 (i, j − 1 / 2, k + 1 / 2) ⎥ ⎥ ⎢ x n +1 / 2 ⎣⎢ − H x (i, j + 1 / 2, k + 1 / 2) ⎦⎥ (6.80)
From Equations 6.75–6.80, the six field components are calculated from the previous values of the specific location as well as the previous values of
Computer Simulation for Microwave Heating
115
the neighboring field components. The computation approaches one grid at each time step and is terminated after a steady state is reached. We also assume that the permeability is isotropic and timeindependent, but the dielectric constant and electrical conductivity are dependent on both time and space. It is well known that a least 10 grids are needed in one wavelength to keep FDTD algorithm valid (Chen et al. 2007). In addition, for accuracy and stability, the time step δ t is limited by a value determined by the local media and the cell size in three directions.
δt ≤
1 (ε t )min −2 −2 −2 c (δ x )max + (δ y)max + (δ z )max
(6.81)
where c is the speed of light in free space. We also explicitly denote the subscript t of dielectric constant to emphasize its time dependence in food applications. To ensure the stability of the program everywhere and anytime in the problem space, Equation 6.81 has to be satisfied.
6.5.2. ABC When dealing with MW-heated food, the EM wave is treated as a plane wave to the object so that it is assumed that MWs approach the food package from infinity, part of its energy is absorbed by the food and part is reflected back to infinity. To allow a computer with limited memory to handle the computation, it is necessary for the model to be able to terminate the computation at particular space grids while, at the same time, keeping the scatter field effectively approaching into infinity. To meet this requirement, the lattice boundary should allow outgoing numerical wave propagation and suppress reflected waves from all directions. This lattice truncation is theoretically called ABC. The formulations of ABC were developed in Taflove (1998) by using Taylor series approximation. Using Taylor series expansion, one can obtain first-order, second-order, and higher order ABC. While the first-order ABC introduces large calculation errors, higher order ABCs increase mathematic
116
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
and programming overhead. Therefore, the secondorder ABC is used in our numerical model because of its relative higher accuracy compared with the first-order ABC and moderate computational demand compared with higher order ABCs. For the secondorder ABC, every node on the lattice boundary needs a 2D array to store its past and the current values of the interior nodes to facilitate calculations. A 3D lattice has six faces, each has two tangential fields so that total 72 2D arrays are needed to facilitate the calculations. For the sake of illustration, we assume there is an Ez field component tangential to the boundary x = 0. The second-order ABC is implemented in the following formulation: 2 − s − 1 / s n+1 [ Ez (2, j, k ) + Ezn−1 (0, j, k )] 2 + s + 1/ s 2(1 / s − s) ⎡ Ezn (0, j, k ) + Ezn (2, j, k ) ⎤ + 2 + s + 1 / s ⎢⎣ − Ezn+1(1, j, k ) − Ezn−1(1, j, k ) ⎥⎦ 4(1 / s + s) n Ez (1, j, k ) − Ezn−1 (2, j, k ) + (6.82) 2 + s + 1/ s
Ezn+1 (0, j, k ) =
where s = δ t μεδ 0, j ,k . Here we only present the updated equation for Ez on the lattice boundary; for the other components tangential to the boundary, the update equations are similar. The complete set of update equations for ABC is presented in (Taflove 1998).
6.5.3. Source Specification For illustration purposes, we only focus on MW heating of food packages. For those applications, the plane wave excitation instead of pulse excitation is found to be more suitable (Ma et al. 1995). Thus, we use a sinusoidal plane wave with a prescribed energy level as the excitation source. In numerical modeling to radiate the desired plane wave in the computation lattice, a simple approach is to place the excitation plane on the lattice boundary. However, this does not account for any possible outgoing fields scattered by the object, hence introducing undesired reflected wave that distorts the final results. Thus the excitation source is placed on a reference plane several cells away from the lattice
boundary. This placement introduces the desired plane wave propagating through the FDTD grids and, in the meantime, allows the reflected fields to propagate into infinity through the lattice boundary without any reflection. As an example, assuming a sine wave with the dominant TE10 mode in a rectangular waveguide far away from an object, it only has E y field component and propagates into zdirection. We then set up the excitation plane at k = 3: E yn (i, j, 3) ← E0 sin(2π fnδ t ) + E yn (i, j, 3)
(6.83)
where E0 is determined by a specified source power. In the numerical simulation, the sinusoidal wave was activated at time step n = 1 and left on until steady state is established, which usually needs four or five wave cycles.
6.5.4. EM Energy Related to MW Heating After numerically solving E and H equations, the dissipated power for each unit volume inside a food package can be calculated as a root mean square of the electric field: 2 q (r , T ) ≈ 2πε 0 fErms ε ′′(r , T ) ( E * ∗ E )dV ∫ = 2πε 0 f V ε ′′(r , T ) 2V
(6.84)
6.5.5. Finite Difference Equations for Heat Transfer In calculating temperature distributions, we consider two types of heat transfer during a MW heating process: (1) heat conduction that takes place inside food package, and (2) heat convection at the surface of food package between food and water that surrounds the food package. In this section, a thermal model is developed to numerically solve both types of heat transfer (Incropera and DeWitt 2001).
ρ(T )c p (T )
∂T = ∇ ⋅ ( K (T )∇T ) + q (r , T ) ∂t q = hA(Ts − T )
(6.85) (6.86)
Chapter 6
Equation 6.85 describes the relationship between partial derivatives of temperature with heating time. Thermal conductivity K (T ), mass density ρ(T ) and specific heat c p (T ) are functions of temperature T. Equation 6.86 calculates the temperature on the surface of food package from the heat exchange between food and water. Here h is the heat transfer coefficient of 220 Wm −2 k −1 (heat transfer value varies with different conditions). The value of 220 Wm −2 k −1 was obtained from experiments where the temperature history was adjusted to match the measured temperature at a cold spot of a food package merged into hot water and A is the surface area of food package. The heat transfer equation Equation 6.85 is solved numerically with the FDTD method by using the same 3D mesh generated for the EM field. Its finite difference form between FDTD cells is T n+1 (i, j, k ) = (1 − 12 F0 )* T n (i, j, k ) + F0 [T n (i − 1, j, k ) + T n (i + 1, j, k ) + T n (i, j − 1, k ) + T n (i, j + 1, k ) + 4T n (i, j, k − 1) q (i, j, k )Δt + 4T n (i, j, k + 1)] + (6.87) ρc p For illustration purposes, we use a cell setup of Δx = Δy = 2Δz for all finite difference equations. On the surface of the food package, besides the MW heating, there is heat convection introduced by surrounding hot water. For the nodes on the surface vertical to z-plane, to calculate the boundary condition, the thermal equation q = hΔxΔy[Ts − T (i, j, k , n)] was used to replace the conduction term [T (i, j, k + 1, n) − T (i, j, k , n)] ∗ K ∗ Δx .
6.5.6. Communication Algorithm between EM and Thermal Field The electric and magnetic fields are solved with an EM solver Quick Wave -3D (QW3D, Warsaw, Poland) that employs the conformal FDTD method. In QW3D, the physical geometry was defined in a parameterized macro as a user-defined object. In this object file, the MW heating system is represented as a metal box with a Perfect Electrical Conductor
Computer Simulation for Microwave Heating
117
(PEC) surface. Since its operating frequency is 915 MHz, only TE10 can propagate through the rectangular waveguide on the top and bottom of the system to be simulated (Balanis 1989). Once the model is developed with the specified source type, input power, and boundary conditions, the mesh for the EM field can be generated automatically in QW3D by using conformal FDTD method. The mesh is then kept in an external file so that it can be imported into the heat transfer model to calculate temperature response caused by MW heating. The coupling between the EM and the thermal field is defined in a script that exchanges data between the EM and the thermal model and calculates the temperature response. Once the temperature is updated, the dielectric properties and the loss factor also change, which requires the temperature to be recalculated (Chen 2008). In QW3D, it is possible to extract the power density of a subdomain inside a food package, which significantly reduces the size of the data set handled by the EM and the thermal model. During MW heating, the temperature distribution is obtained from the EM power dissipated inside the food package, and then new dielectric properties are calculated with a linear interpolation technique in QW3D. So there are two steps happening in the communication algorithm between EM and thermal field. First, the dissipated power is calculated by solving the integrated Maxwell’s equations with conformal FDTD method; second, the dissipated power is used to calculate the temperature response, which results in the change of the thermal properties. Finally, once the thermal properties are updated, the EM field needs to be reevaluated as well. The steps of the algorithm are 1. Obtain dissipated power by solving Maxwell’s equations with conformal FDTD method (i.e., QW3D). 2. Initialize temperature for computation in the next time step based on the previous temperature distribution. 3. Loop through the whole computational grid. (a) For each inner node, calculate dissipated power by taking mean values of the power
118
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
density from the node itself and its adjacent nodes. (b) For boundary nodes, set the corresponding power from corresponding nodes to zero. (c) Conduct heat transfer calculation. 4. Update the temperature distribution and feedback to QW3D and repeat step 1.
6.5.7. Model Validation A numerical model is not very useful until it is validated. To check the validity of the FDTD technique proposed in previous sections, the electric field inside a cylindrical food model is calculated and compared with the analytical results. The cylindrical model is shown in Figure 6.7. The cylinder was assumed to have an infinite length in z-direction and circular cross section in the x-y-plane. For simplification purposes, it was assumed that the cell size was uniform in the whole computational lattice, that is, δ x = δ y = δ . The cylinder had a radius of 20δ . The incident wave was assumed to be a sinusoidal wave with an operating frequency of f0 . We investigated two cases, with frequencies of f0 = 0.915 GHz and
j * dy
(25
1 2
)
, 25 12 ,
The geometry function to describe this object was
(i − 25 ) + ( j − 25 ) 1 2 2
1 2 2
≤ 20
(6.88)
Thus, for each pair (i, j ) , if it satisfied (Eq. 6.88), we assigned dielectric parameters for the specified food package; otherwise, the dielectric properties for free space were used. Due to the 2D lattice, the plane wave source was specified as the following according to Equation 6.88: Ez (i, 3) ← Ez (i, 3) + 1000 ∗ sin(2π fnδ t )
50
(6.89)
y Cylindrical scatter x
25.5 Hy
Ez 0
f0 = 2.45 GHz , which are designated by the U.S. Federal Communications Commission (FCC) for MW applications. Because the cylinder was infinite in z-direction, there was no variation in this direction with respect to the geometry and the incident fields. Thus, this problem could be treated as a 2D scattering problem. In addition, we assumed that the incident wave was a +y-directed TM wave; therefore, it only had three field components involved in this simulation: Ez, Hx, Hy. Based on the above analysis, we built a 2D computational lattice consisting of 50 grids in each direction. Each of them contained a medium with dielectric parameters dependent on its location. The center of the cylinder was assumed to be the central point of the lattice
20d Computational domain
Hx 25.5
50
Another interesting feature of this problem was that the modeled structure was symmetric over the center line. The dielectric properties were also assumed to be symmetric over the same line. In addition, since the incident wave was in +z-direction, the field components that were normal to the propagation direction were symmetrical: E yn (26, j ) = E yn (25, j )
(6.90)
H xn (26, j ) = H xn (25, j )
(6.91)
i * dx
Figure 6.7. Cylindrical food model to verify the FDTD algorithm.
Therefore, we truncated the computational lattice on the center line and imposed the update equations for
Chapter 6
119
(a) 1300 exact calculated
1200 1100 Ez (15j)
1000 900 800 700 600 500 400 300
(b)
5
10
15
20
25 j
30
35
40
45
25 j
30
35
40
45
1400 exact calculated
1200 1000 Ez (25j)
field components to reduce computer memory storage and simulation time. As indicated earlier, we investigated two cases for validation purposes. One was for the food package exposed to MWs with a frequency of 0.915 GHz; the other one was the same food package exposed to MWs with a frequency of 2.45 GHz. The modeled food had the following dielectric parameters: ε ′f = 4ε 0, ε ′′f = 0. Therefore, for the case with a frequency of f0 = 0.915 GHz, the wavelength was λ f = c 4 f0 = c 2 f0 = 0.16 m . Using 80 discrete points per wavelength used in FDTD technique, the cell size was δ = λ f 80 = c 160 f0 = 0.002 m; the time step was chosen according to δ t = δ 2c = 3 ps. Thus, it required 320 time steps to complete the simulation for one wave cycle. Since it usually needs four or five wave cycles to reach the steady state, 1,600 time steps were used in the simulation. The maximum absolute value of the electric field E y (25, j ) and E y (10, j ) in the last half wave cycle were then recorded and compared with the analytical results, computed using series expansion method (Jones 1964). The results are presented in Figure 6.8. Both results show a good agreement. The numerical model correctly predicted the location of peak and null of the envelope of the electric field with a maximum error of δ . It was also shown that the amplitude of the induced electric field inside the cylinder was approximated with only 5% error presented. In the second case, the numerical results for the same cylindrical food exposed to MWs at a frequency of f0 = 2.45 GHz were computed using the same parameters as in the literature (Taflove and Brodwin 1975a, 1975b) for validation and comparison purposes. At this frequency, with the same deduction as the last example, we had λ f = c 2 f0 = 0.06 m. Twenty discrete points per wavelength were used. Thus, the cell size used for this case was δ = λ f 20 = 0.003 m; the time step is then δ t = δ 2c = 5 ps. These selections required 80 time steps for simulating one complete wave cycle. As before, five wave cycles are used to achieve the steady state. Results are reported in Figure 6.9.
Computer Simulation for Microwave Heating
800 600 400 200
5
10
15
20
Figure 6.8. Comparison between numerical and analytical results for 915 MHz microwave-irradiated cylindrical food package.
Again, similar results were obtained from simulated and analytical calculations. The maximum error of the amplitude of the electrical field is within 10% of the incident amplitude, while the expected location of field peaks deviated from the analytical solution less than δ . Another observation was that there were only one nulls of the envelope of Ez in Figure 6.8 but four nulls in Figure 6.9. This is because the radius of the cylinder was equal to the wavelength in the first scenario (Figure 6.8) while
120
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Temperature profile for hot water heating only
(a) 1400
80
exact calculated
70 Temperature (°C)
1200
Ez (15j)
1000 800 600 400
50 40 30
FDTD FEM Experimental result
20
200 0
60
10 5
10
15
20
25 j
30
35
40
45
0
0
500
1000
1500
2000
2500
Heating time (second) Figure 6.10. Validation of the heat transfer model.
(b) 2200 exact calculated
2000 1800
Ez (25j)
1600 1400 1200 1000 800 600 400 200
5
10
15
20
25 j
30
35
40
45
Figure 6.9. Comparison between numerical and analytical results for microwave-irradiated cylindrical food package at a frequency of 2450 MHz.
equal to a quarter of the wavelength in the second scenario (Figure 6.9). Therefore, a single mode EM field is achieved at 915 MHz while multimode is inevitable at 2450 MHz. For food applications, the multimode system brings up a critical problem: The cold spot in packaged foods during MW heating processes cannot be predicted with confidence. Since the temperature at the cold spot needs to reach over 121°C to ensure the safety of the food (Guan et al. 2004), it is desirable for a MW heating system
to keep the cold spot fixed. A unique design to provide 915 MHz single-mode MW field pattern in foods is described in Chen et al. (2007). Parallel to the development and validation of a numerical model for the EM field, the numerical model for the heat transfer also needs to be validated independently before it can be coupled with the EM model to simulate an MW heating process. Since the FDTD method is employed to solve the heat transfer equations, an FEM model and experimental measurements are used to validate the FDTD results for the heat transfer (Figure 6.10). The simulation result for the heat transfer calculated by the FDTD method is shown as solid red line; the dashed blue line is the simulation result calculated by using the FEM model. Directly measured temperature response from an experiment is shown in the yellow solid dashed line. The difference between the calculated temperature and the actual measurement was less than 1°C, which shows a good agreement. It is noted that the simulated heating curve varies with different heat transfer coefficient. Therefore, to achieve the best agreement between simulation and experiment results for hot water heating, the heat transfer coefficient was set to 220 Wm−2 k−1.
Chapter 6
6.6. Simulation Model for MW Sterilization 6.6.1. Introduction MW energy heats solid food products in a short time period, thus offers the potential to overcome the limitation of slow conventional heating that relies on heat conduction within food packages (DeCareau 1985; Burfoot et al. 1988; Harlfinger 1992; Meredith 1998) and significantly improves product quality (Stenstrom 1974; O’Meara et al. 1977; Ohlsson 1987; Ohlsson 1991; Giese 1992; Guan 2003). For MW sterilization processes, heating uniformity is very important. On one hand, the product temperature at the cold spots should reach a desired level (∼120°C) to kill Clostridium botulinum spores and cause a reduction of heat resistant spoilage microorganisms. On the other hand, the temperature at the hottest spot should not be too high to cause bursting of package or melting of plastic package materials. It is difficult to design MW systems that provide relative stable and uniform heating because of standing waves. The discontinuity in the EM field components at the boundary between food packages and surrounding medium also cause nonuniform distribution of the MW field within the food packages (Ayoub et al. 1974; DeCareau 1985; Ruello 1987; Schiffmann 1990; Stanford 1990). Severe corner and edge heating may result from the nonuniform heat distribution (Ohlsson 1991). Many techniques have been developed to improve heating uniformity. Instead of air, water is used as the surrounding medium of food packages to minimize the nonuniform heating effects (Stenstrom 1972; Ohlsson 1992; Lau 2000; Guan et al. 2002; Guan 2003). As mentioned before, for MW heating purposes, two frequencies are designated by the U.S. FCC: namely, 915 MHz and 2450 MHz. A frequency of 2450 MHz is used in domestic MW ovens and some of the industrial MW systems. However, the high operating frequency produces multimode EM fields inside the cavities, making heating patterns difficult to predict and control, in particular when food packages are processed on moving belts. Recent studies (Guan 2003; Chen et al. 2007) have indicated that it is possible to use single-mode 915 MHz MW
Computer Simulation for Microwave Heating
121
heating systems to provide relatively uniform heating and more stable heating patterns within food products both in pouches and trays. The following section discusses the use of computer simulation models to study electric field distributions and temperature distributions in prepackaged mashed potato processed in a 5-kW 915 MHz MW sterilization system developed at Washington State University (WSU; Pullman, WA). The models have been validated using the chemical marker M-2 method and direct temperature measurements using fiber-optic temperature sensors (Chen et al. 2007, 2008).
6.6.2. Physical System The considered MW sterilization system consists of a rectangular cavity with one horn-shaped applicator on the top and another identical applicator on the bottom. Figure 6.11 shows a front view of the system with an exposed interior cut and a vertical central
Microwave in Rectangular waveguide Water
Horn waveguide
Microwave transparent pressure window
Air
Air Food
Horn waveguide
z Rectangular waveguide x Microwave in Figure 6.11. Pilot-scale EM heating system (front view).
122
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
water
food
Table 6.1. Dielectric properties of mashed potato at different salt levels (Guan et al. 2004). Salt content 0% 0.5% 1.0%
Dielectric constant (ε′)
Loss factor (ε″)
54.5 52.3 48.7
38.1 68.5 95.2
y cavity x Figure 6.12. Pilot-scale microwave heating system (top view).
plane, while Figure 6.12 shows the top view for the central section of the cavity. MW energy is provided by a 5-kW generator operating at a frequency of 915 MHz through a standard waveguide that supported only TE10 mode. After passing through a circulator, the MW energy is equally divided at a T-junction and fed to the two-horn applicators through two standard waveguides. The length of each leg of the waveguide after the T-junction could be adjusted to control the phase difference between the MWs at the entry port of the two-horn applicators, which meant the phase shift between the two waves interacting inside the cavity could be controlled to achieve the desired field distribution in foods. The MW horn applicator and the processing cavity are separated by a MW transparent window to allow circulation of pressurized water preheated by a heat exchanger to 121°C. Prepackaged mashed potato or other foods are heated by the combination of MW energy and surface water. More details about the system can be found in Chen et al. (2007).
6.6.3. Numerical Modeling for MW Sterilization Process A detailed description of a computer model for simulating MW sterilization process containing stationary and moving food packages is provided in Chen et al. (2008). This model was developed and
validated following the steps described in Section 6.5. The simulated temperature patterns agreed well with the heating patterns indicated by brown color through formation of Chemical Marker-2 (4-hydroxy-5-methy-3(2H)-furanone) in whey protein gel. Detailed information about kinetics for formation of M-2 can be found in Lau and Tang et al. (2003). The following part of the section illustrates its use to study the influence of dielectric properties of foods on heating uniformity for two different cavity configurations (cases 5 and 6), each providing a specific MW-induced heating pattern in foods. Under a confidentiality agreement with industrial partners of the WSU MW Sterilization Consortium, we cannot reveal detailed information for those two configurations. But we are confident that the simulation results demonstrate the benefits of computer simulations. In this simulation, we consider three different levels of salt content in mashed potato shown in Table 6.1. Figure 6.13 shows the meshed geometry of the modeled system (Figure 6.12). Figure 6.14a–c shows the predicted electric field distribution in different cross-sectional areas in mashed potato. It is observed that the overall general electric field intensity patterns in the central horizontal plane (top view) of the food do not vary with salt contents. But salt content significantly changes the MW penetration (front and side views). At 0% salt content, the food predominantly undergoes center heating, while at 1.0% salt content, the food mainly shows surface heating. These observations have been confirmed by our experimental results using chemical marker M-2.
Chapter 6
Computer Simulation for Microwave Heating
123
Monitored tray
(a) Case 5
(b) Case 6
Figure 6.13. Mesh for modeled geometry.
Figure 6.15 shows simulated temperatures at the cold spot and its adjacent location (8 mm apart) in the mashed potato as the package passes through two interconnected MW cavities. The results show the sensitivity of the location within a food package to temperature rise close to the point of cold spot, and indicate what would happen if a temperature sensor is placed slightly off the predetermined cold spot. Figure 6.16 shows the temperature distributions in mashed potato at a cross-sectional area at simulation time t = 100 s, t = 150 s, t = 270 s, and t = 320 s when immersed in water at 125°C while being heated by 915 MHz MW energy in a single-mode cavity. With increasing heating time, the center product temperature was increased by MW heating. We also used the simulation model to study heating uniformity in a larger MW system developed at WSU. This system has four connected MW cavities while food packages are moved on a conveyor belt through those cavities to complete a sterilization process under circulation of water at a temperature of 125°C. For the simulation, we used power settings of 16.5 KW, 7 KW, and 5 KW, respectively, for each of the four cavities. The food packages moved through the central plane of the heating cavities.
Results were obtained that show the temperature distributions over the y-z-plane where the cold spot was located. The temperature distributions were selected to represent the intermediate status during the process, which were the time steps when the food packages pass the center of the respective MW cavity. It is also observed that the temperature difference decreased along the moving direction (x-direction; Figure 6.17). As in the previous case, steeper change was found along z-direction than that found in ydirection. It should be noted that the final temperature distribution at t = 340 s was much smoother than those at previous time steps since the temperature value at any point varied only within a small range (<5°C). In this section, the temperature distributions over the vertical surface of the y-z-plane where the cold spot was found were evaluated using computer simulation. This information was used to facilitate the validation of the optical sensor measurement of the temperatures used to develop appropriate thermal process parameters (e.g., belt moving speed, holding time after MW heating). Although not presented here, smooth patterns after MW heating were found in the x-direction.
× 10–3 5 4.5 4 3.5 3 2.5 2 1.5 1 0.5
18 16 14 12 10 8 6 4 2 2
4 2
2
4
6
8
10
12
14
16
18
0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 × 10–3 Side view (y-z) 4 2
2
4
6
8
10
12
14
16
18
0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 × 10–3
4 6 8 10 12 14 16 18 Top view of central plane (x-y)
Front view (x-z)
(a) Electric field distribution (density) inside mashed potato with 0% salt content. × 10–3
18
4 2
3.5
16
12
14
2.5
3
3.5 × 10–3
12
14
16
0.5 1 1.5 2 2.5 4 6 8 10 12 14 16 18 Top view of central plane (x-y) Front view (x-z) (b) Electric field distribution inside mashed potato with 0.5% salt content.
3
14
3
12
2.5
10
2
8
2 0.5
4 2
1
4
6 1
8 1.5
10 2
2
4
6
8
10
0.5
2
2
× 10–3
18
4 2
3.5
16 14
3
12
2.5
10
2
8 4
1
2
0.5 2
4
6
8
10
12
14
2
4
0.5
6
1
8
1.5
10 2
12
14
2.5
3
Side view (y-z) 4 2
1.5
6
16
18
Side view (y-z)
1.5
6
4
2 0.5
16
Top view of central plane (x-y)
4 1
6 1.5
8
10 2
12
14
2.5
3
18
18
3.5 × 10–3
16
18
3.5 × 10–3
16
18
3.5 × 10–3
Front view (x-z)
(c) Electric field distribution (density) inside mashed potato with 1.0% salt content. Figure 6.14. Electric field distribution (top, front, and side views) inside a food package containing mashed potato with different salt contents. (a) Electric field distribution (density) inside mashed potato with 0% salt content. (b) Electric field distribution inside mashed potato with 0.5% salt content. (c) Electric field distribution (density) inside mashed potato with 1.0% salt content. See color insert.
124
Temperature profile from simulation at selected point 110 Cold spot 105 One point to the 100 left of cold spot 95 90 85 80 75 70 65 60
0
1
2
3
4
5
6
Heating time (minute) Figure 6.15. Temperature profile at neighboring points from the cold spot.
115
120
110
110
105
100
100 95
90
90 85
80 70 20 15 10 y
80 5
2
0 1
3
z
5
4
6
75
125 120 115 110 105 100 95 90 85 80 20
120 115 110 105 100 95 90 15 10 y
5
120 115 110 105
10
y
5
0 0
t = 270 s
2
z
4
6
122 120 118 116 114 112 110 108 106 104
0 0
z
4
85
124 122
125 Temperature (°C)
Temperature (°C)
125
15
2
6
t = 150 s
t = 100 s
100 20
125
In this chapter, we provided a general overview of methods to calculate and validate EM field and coupled EM and thermal equations. We then used case studies to illustrate computer simulation models developed using the FDTD method for studying MW sterilization processes. It was shown that MW sterilization technology as an emerging novel technology has significant benefits over conventional methods. It significantly reduces the processing time to reach the required temperature level and thus it is possible to largely retain the quality of the heated food package. The 915 MHz single-mode sterilization technology developed at WSU uses a combination of hot water and MW heating that also improves heating uniformity.
120
130 Temperature (°C)
Computer Simulation for Microwave Heating
6.7. Conclusion
Temperature (°C)
Temperature (°C)
Chapter 6
120
120
118
115
116 114
110 105 20
112 110 15
10 y
5
0 1
2
3
4
5
6
108
z
t = 320 s
Figure 6.16. Temperature distribution at a vertical plane in mashed potato for different heating times. Mashed potato was immersed in 125°C water while heated with 915 MHz energy. See color insert.
126
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
120
122
125 120 115 110 105 100 95 90 85 80 20 18 16
110 105
14 12 10 5 8 6 4 y 2 0 6
3 4 z
2
1
0
100 95
120
125 Temperature (°C)
Temperature (°C)
115
118
120
116
115
114
110
1 2 3 105 4 z 20 18 16 14 12 5 10 8 6 4 2 0 6 y
t = 60 s
124
130
122
125
120
120
118
115 5
6
116
Temperature (°C)
Temperature (°C)
112 110 108
t = 150 s 126
4 110 3 0 2 4 6 2 z 8 10 12 14 1618 20 0 1 y
0
130 129 128 127 126 125 124 0 2 4 6 8 10 12 14 16 18 20 0 y
129.5 129 128.5 128 127.5 127 126.5 126 6 125.5 5 4 3 125 2 z 1
t = 230 s t = 340 s Figure 6.17. Temperature distribution in a vertical plane at different simulation time corresponding to the central position of each of the four MW heating cavities.
In developing the MW system configuration, we used computer simulation models for EM field calculations, while in evaluating temperature distribution for process development we used a coupled EM field and heat transfer model. Both models were developed using the FDTD methods and validated step-by-step with analytical and experimental test results. The single-mode EM wave patterns in the system make it possible to track the heating patterns in the packaged foods during the thermal process. Without the use of computer simulation models, it is extremely expensive and time-consuming to design such complicated systems by doing trial-anderror experiments, especially for high-power industrial applications. This is due to numerous variables influencing the heating patterns in MW systems,
leading to a large number of combinations of variables that need to be considered in the design. In fact, the high labor and equipment costs keep food manufacturing companies from making adequate investment in research and development effects in this direction.
Notation Latin Symbols Boundary surface area A A1, A2, Constants B1, B2, C1, C2 aˆ Unit vector in coordinate directions
m2 –
–
Chapter 6
a, b, c B
Constants Magnetic flux (density)
C CP
Contour path Specific isobaric heat capacity Specific volumetric heat capacity Speed of light in free space (vacuum) Electric flux density Electric field Element number in FEM Frequency Heat transfer coefficient Magnetic field intensity Spatial index Space points Equivalent current density Source current density Conduction current density Imaginary unit Thermal conductivity Wave number Numerical wave number Number of elements in FEM Normal unit vector/ component of surface Time step Dissipated microwave power Dissipated power density provided by heating source Thermal energy provided by circulating water on the boundary Electric charge density
CV c D E e f h H i I, j, k Jeq Ji JC j K k k1 N nˆ n Pd q q
q r, r′ S T TS t u V
Space points Surface for computation domain Temperature Circulating water bath temperature Time Speed of light Voltage/potential
– T = V·s·A−1· m−1
Computer Simulation for Microwave Heating
Element potential in FEM Volume Phase velocity Energy
Ve V vP W
127
V m3 m·s−1 J
J·kg−1·K−1 J·kg−1·K−1 m·s−1 −2
A·s·m V·m−1 – Hz, s−1 W·m2·K−1 A·m−1 – – A·m−2 A·m−2 A·m−2 −1 W·m−1·K−1 m−1 m−1 – – – W·m−3 W·m−3 J C·m−3 = A·s·m−3 – –
Greek Symbols 8.854·10−12 A·s·V−1·m−1 Relative dielectric constant – Complex dielectric permittivity – Real part of complex permittivity – Imaginary part of complex – permittivity, dielectric loss factor Wavelength m Wavelength in free space/ m vacuum Permeability of vacuum =1/ε 0c20 = 1.257·10−6 V·s·A−1·m−1 Relative magnetic permeability – Dielectric permeability – Ludolph’s number, circular ≈ 3.14159 constant Mass density kg·m−3 Conductivity S·m−1 Propagation constant – Field solution – Angular frequency Hz = s−1
ε0 Dielectric constant of vacuum εr ε ε′ ε″ λ λ0 μ0 μr μ π ρ σ γ Ψ ω
Coordinates x, y, z ρ, ϕ, z r, φ, ψ
Cartesian coordinates Cylindrical coordinates Spherical coordinates
Operators
°C °C
∂ ∇ ∑ Δ, δ
s m·s−1 V
∇⋅ ∇× f, g, h
Partial differential Nabla operator Sum Difference (but also denoting cell sizes in mesh discretization) Divergence Curl Functions
128
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Functions G0(r,r′) Hm(1)(βρρ) Hm(2)(βρρ) hn(1)(βr) hn(2)(βr) Jm(βρρ) Ym(βρρ) jn(βr) yn(βr) 2 O ⎢⎣( Δx ) ⎥⎦
Green’s function First Hankel function Second Hankel function First spherical Hankel function Second spherical Hankel function First Bessel function Second Bessel function First spherical Bessel function Second spherical Bessel function Notation for higher order terms in Taylor expansion
Abbreviations 1D 2D 3D ABC EM EMI FCC FDM FDTD FEM MoM MW M-2 PEC PV RTD rms SAR TIE
One-dimensional Two-dimensional Three-dimensional Absorbing boundary condition Electromagnetic Electromagnetic interference Federal Communications Commission Finite difference method Finite difference time domain Finite element method Method of moments Microwave Chemical compound for heating pattern determination Perfect electrical conductor Principal value Resistance temperature detector Root mean square Specific absorption ratio Tensor integral equation
References Ayoub J, Berkowitz D, et al. (1974).Continuous microwave sterilization of meat in flexible pouches. J Food Sci 39: 303–313. Balanis CA. 1989. Advanced Engineering Electromagnetics. John Wiley & Sons. Burfoot D, Griffin W, et al. (1988).Microwave pasteurization of prepared meals. J Food Eng 8:145–156. Chen H. 2008. Computer simulation of combined microwave and water heating processes for packaged foods using finite
difference time domain method. PhD, Department of Biological Systems Engineering, Washington State University, Pullman, WA, USA, 97–102. Chen H, Tang J, et al. (2007). Coupled simulation of an electromagnetic heating process using the Finite Difference Time Domain method. J Microwave Power Electromagn Energy 41(3):50–68. Chen H, Tang J, et al. (2008). Simulation model for moving food packages in microwave heating processes using conformal FDTD method. J Food Eng 88:294–305. Cook HF. 1952. A physical investigation of heat production in human tissues when exposed to microwaves. Br J Appl Phys 3:1–6. DeCareau R. 1985. Microwaves in the Food Processing Industry. New York: Academic Press, Inc. Desmarais R, Breuereis J. 2001. How to select and use the right temperature sensor. Sensor 18(1). Giese J. 1992. Advances in microwave food processing. Food Technol 46:118–123. Guan D. 2003. Thermal processing of hermetically packaged low-acid foods using microwave-circulated water combination (MCWC) heating technology. Washington State University, 2003.: xix, 167 leaves, bound. Guan D, Plotka V, et al. (2002).Sensory evaluation of microwave treated macaroni and cheese. J Food Process Preserv 26:307–322. Guan D, Cheng M, et al. (2004).Dielectric properties of mashed potatoes relevant to microwave and radio-frequency pasteurization and sterilization processes. J Food Sci 69(1):E30– E37. Guru BS, Chen KM. 1976. A computer program for calculating the induced EM field inside an irradiated body. Department of Electrical Engineering and System Science Michigan State University, East Lansing, MI 48824. Guy AW, Lin JC, et al. (1974). Measurement of absorbed power patterns in the head and eyes of rabbits exposed to typical microwave sources. Proc. 1974 Conf. Precision Electromagnetic Measurements (London, England), 255–257. Harlfinger L. 1992. Microwave sterilization. Food Technol 46(12):57–60. Harrington RF. 1961. Time-Harmonic Electromagnetic Fields. New York: McGraw-Hill. Harrington RF. 1967. Matrix methods for field problems. Proc IEEE 55(2):136–149. Harrington RF. 1968. Field Computation By Moment Methods. New York: Macmillan. Harrington RF. 1992. Origin and Development of the Method Moments for Field Computation. New York: IEEE Press, Computational electromagnetics. Hilderbrand FB. 1962. Advanced Calculus for Applications. Englewood Cliffs, NJ: Prentice-Hall. Incropera FP, DeWitt DP. 2001. Introduction to Heat Transfer, 4th ed. New York: John Wiley & Sons. Jones DS. 1964. The Theory of Electromagnetism. New York: Macmillan.450–452.
Chapter 6
Jurgens TG, Taflove A, et al. (1992).Finite-difference timedomain modeling of curved surfaces. IEEE Trans Antennas Propag 40(4):357–366. Kastner R, Mittra R. 1983. A new stacked two-dimensional spectral iterative technique (SIT) for analyzing microwave power deposition in biological media. IEEE Trans Microwave Theory Tech MTT-31(1):898–904. Kim HJ, Taub IA. 1993. Intrinsic chemical markers for Aseptic processing of particulate foods. Food Technol 47(1):91–97. Kong JA. 1981. Research Topics in Electromagnetic Theory. New York: John Wiley.290–355. Kunz KS, Lee KM. 1978. A Three-Dimensional Finite-Difference solution of the external response of an aircraft to a complex transient EM environment: Part I—The method and its implementation. IEEE Trans Electromagn Compat EMC-20(2). Lau MH. 2000. Microwave heating uniformity in model food systems. From Microwave pasteurization and sterilization of food products. PhD dissertation, Washington State University, USA. Lau RWM, Sheppard RJ. 1986. The modelling of biological systems in three dimensions using the time domain finitedifference method: Part I. The implementation of the model. Phys Med Biol 31(11):1247–1256. Lau MH, Tang J, et al. (2003).Kinetics of chemical marker formation in whey protein gels for studying microwave sterilization. J Food Eng 60(4):397–405. Livesay DE, Chen KM. 1974. Electromagnetic fields induced inside arbitrary shaped biological bodies. IEEE Trans Microwave Theory Tech MTT-22(12):1273–1280. Ma LH, Paul DL, et al. (1995).Experimental Validation of a Combined Electromagnetic and Thermal Fdtd Model of a Microwave-Heating Process. IEEE Trans Microwave Theory Tech 43(11):2565–2572. McDonald BH, Wexler A. 1972. Finite-element solution of unbounded field problems. IEEE Trans Microwave Theory Tech (1972 Symp, Issue) MTT-20:841–847. Meredith R. 1998. Engineer ’s Handbook of Industrial Microwave Heating. United Kingdom: The Institution of Electrical Engineers. Michaelson SM. 1969. Biological effects of microwave exposure. Proc. Biological Effects and Health Implications of Microwave Radiation Symp, Med. College Virginia (Richmond), Rep. BRH/DBE 70(2):35–58. Mittra R, ed. 1973. Computer Techniques for Electromagnetics. New York: Pergamon. Ohlsson T. 1987. Sterilization of foods by microwaves. International Seminar on New Trends in Aseptic Processing and Packaging of Food stuffs, 22 October 1987, Munich. SLK Report nr 564. Goteborg, Sweden: The Swedish Institute for Food and Biotechnology. Ohlsson T. 1991. Microwave heating uniformity. AICHE Conference on Food Engineering, Chicago. March 11–12. Ohlsson T. 1992. Development and evaluation of microwave sterilization process for plastic pouches. Paper presented at the
Computer Simulation for Microwave Heating
129
AICHE Conference on Food Engineering, March 11–12, Chicago. Okoniewski M. 1993. Vector wave equation 2D-FDTD method for guided wave equation. IEEE Microwave Guided Wave Lett 3(9):307–309. O’Meara J, Farkas D, et al. (1977). Flexible pouch sterilization using combined microwave-hot water hold simulator. Contact No. (PN) DRXNM 77–120, U.S. Army Natick Research & Development Laboratories, Natick, MA 01760. Pandit RB, Tang J, et al. (2006).Kinetics of chemical marker M-2 formation in mashed potato—A tool to locate cold spots under microwave sterilization. J Food Eng 76(3): 353–361. Richmond JH. 1965. Digital computer solutions of the rigorous equations for scattering problems. Proc IEEE 53:796–804. Ruello JH. 1987. Seafood and microwaves: Some preliminary observations. Food Technol Aust 39:527–530. Sadiku MNO. 2001. Elements of Electromagnetics. New York: Oxford University Press. Schiffmann R. 1990. Problems in standardizing microwave over performance. Microwave World 11(3):20–24. Schwan HP. 1972. Microwave radiation: Biophysical considerations and standards criteria. IEEE Trans Biomed Eng BME-19:304–312. Spiegel RJ. 1984. A review of numerical models for predicting the energy deposition and resultant thermal response of humans exposed to electromagnetic fields. IEEE Trans Microwave Theory Tech MTT-32:730–746. Stanford M. 1990. Microwave oven characterization and implications for food safety in product development. Microwave World 11(3):7–9. Stenstrom L. 1972. Taming microwaves for solid food sterilization. IMPI Symposium, Ottawa, Ganada. May 24–26. Stenstrom L. 1974. US Patents 3,809,845; 3,814,889. Taflove A. 1980. Application of the finite-difference time-domain method to sinusoidal steady-state electromagnetic-penetration problems. IEEE Trans Electromagn Compat EMC-22(3): 191–202. Taflove A. 1998. Advances in Computational Electrodynamics: The Finite-Difference Time-Domain Method. Boston: Artech House. Taflove A, Brodwin ME. 1975a. Computation of the electromagnetic fields and induced temperatures within a model of the microwave-irradiated human eye. IEEE Trans Microwave Theory Tech MTT-23(11):888–896. Taflove A, Brodwin ME. 1975b. Numerical solution of steadystate electromagnetic scattering problems using the timedependent Maxwell’s equations. IEEE Trans Microwave Theory Tech MTT-23(8):623–630. Taflove A, Umashankar K. 1980. A hybrid moment method/finitedifference time-domain approach to electromagnetic coupling and aperture penetration into complex geometries. IEEE Trans Antennas Propag AP-30(4):617–627. Taflove A, Umashankar K. 1981. Solution of complex electromagnetic penetration and scattering problems in unbounded
130
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
regions. In: Computational Methods for Infinite Domain Media-Structure Interaction, Vol. 46, 83–113. Washington, D.C: ASME. Taflove A, Umashankar K. 1990. The finite-difference timedomain method for numerical modeling of electromagnetic wave interactions. Electromagnetics 10:105–126. Thom A, Apelt CJ. 1961. Field Computations in Engineering and Physics. London: D.Van Nostrand. Tsai LL. 1978. Moment methods in electromagnetics for undergraduates. IEEE Trans Educ E-21(1):14–22.
Wu TK, Tai LL. 1974. Numerical analysis of electromagnetic fields in biological tissues. Proc IEEE(Lett) 62:1167–1168. Wylie CR. 1960. Advanced Engineering Mathematics. New York: McGraw-Hill. Yee KS. 1966. Numerical solution of initial boundary-value problems involving Maxwell’s equations in isotropic media. IEEE Trans Antennas Propag AP-14:302–307. Zhang H, Datta AK. 2000. Coupled electromagnetic and termal modeling of microwave oven heating of foods. J Microwave Power Electromagn Energy 35(2):71–85.
Chapter 7 Simulating and Measuring Transient Three-Dimensional Temperature Distributions in Microwave Processing Kai Knoerzer, Marc Regier, and Helmar Schubert
7.1. Introduction Microwave ovens are commonplace in households and are established there as devices of everyday use. However, the uptake of microwave processes in the food industry is still limited, although they have several advantages over conventional thermal processing of foods. The volumetric heating avoids resistance to heat transport, and thereby enables quality improvement of heated and dried food products. The dissipation of energy within the product also avoids thermal inertia and leads to increased rate of heat transfer. Microwave heating, however, is very dependent on the product itself, its geometry and thermophysical properties. Microwave heating has been proposed as an alternative to traditional heating methods in many food manufacturing processes for several decades. Examples are (re)heating, baking, (pre)cooking, tempering of frozen food, blanching, pasteurization, sterilization, and dehydration (Metaxas and Meredith 1983; Decareau 1985; Buffler 1993; Metaxas 1996; Schubert and Regier 2005; Tang et al. 2008). Although the final objective of each process differs, an increase in product temperature is seen as a common theme.
If the final objective is product preservation, as in pasteurization, sterilization, and drying, it is very important to achieve a treatment with predefined minimum temperatures for a certain time (a minimum time–temperature treatment) or predefined minimum water content for assurance of microbial safety. In other processes, temperatures have to remain below certain values to achieve a desired product quality with a maximum preservation of color, flavor, and vitamins, among other quality attributes. In traditional heating and drying processes, heat transfer is predominantly limited by conducting the heat from the product surface to its center. The locations of the slowest heating or drying region are therefore found in the thermal center of the treated product. This means that overprocessing can occur near surface regions. As microwaves heat volumetrically, they can theoretically improve heating uniformity, leading to better final product quality. Unfortunately, there are a number of well-known microwave specific factors that cause nonuniform heating patterns during microwave processing. Examples of these include microwave focusing effects, corner and edge (over)heating, inhomogeneous electromagnetic (EM) field distributions and variation in dielectric properties in heterogeneous
Innovative Food Processing Technologies: Advances in Multiphysics Simulation, First Edition. Edited by Kai Knoerzer, Pablo Juliano, Peter Roupas, and Cornelis Versteeg. © 2011 by John Wiley & Sons, Ltd. and Institute of Food Technologists. Published by John Wiley & Sons, Ltd. ISBN: 978-0-813-81754-5
131
132
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
food materials. As a consequence of these factors, heating patterns can differ significantly from one product to another. The quality and safety of industrially microwave processed products are compromised when these factors are ignored (Mudgett 1986). It is largely for the reason that microwaveinduced heating patterns are more difficult to predict that such processes have not been widely adopted in the food industry. Product and process development of microwave processing started off as trial-and-error experimentation. To allow for appropriate process and equipment design, optimization and scale-up, while ensuring product safety and economical processing, the knowledge of temperature distributions throughout the microwave-heated products is therefore essential. Measuring transient temperature distributions in three dimensions (i.e., volumetrically), however, is very challenging and—as shown later—only the technology based on magnetic resonance imaging (MRI) can provide sufficient information noninvasively (see Section 7.3). Nowadays, in order to design thermal process operations, the use of models able to predict the temperature distribution during treatment inside a processing unit is desirable. This greatly assists not only in process design and scale-up but also in process approval from governmental regulators by illustrating that the technology and the process is well understood. Calculation of realistic EM field and temperature distributions within microwave equipment and treated product is complicated because of the interacting EM, thermo-, and fluid-dynamic phenomena and thus the necessity of coupling the governing partial differential equations, which ideally are solved in a parallel manner but can be solved sequentially to improve computational efficiency. Due to the lack of powerful computers and appropriate software during the initial introduction of microwave technology to food industry, it was nearly impossible to predict electric field distributions, let alone to accurately model the coupled problem, especially when products were present. Latest advances in computer and information technology assist in overcoming this limitation.
Numerical software packages for solving the separated problems have been commercially available for many years, but software packages coupling the partial differential equation problem, which best describes the real process, have also become available.
7.2. Microwave Thermal Modeling Electromagnetism is described by the partial differential equations introduced by J.C. Maxwell (1865), known as Maxwell’s equations, and the equations describing the interaction of microwaves with different materials, the constitutive relations. Maxwell’s equations: (7.1) ∇⋅D = ρ (7.2) ∇⋅ B = 0 ∂B (7.3) ∇×E = − ∂t ∂D (7.4) ∇×H = j + ∂t Maxwell’s equations describe the coupled theory of the former separately described electric and magnetic phenomena. Equations 7.1 and 7.2 describe the source (ρ) of an electric field E without a magnetic monopole as a source for the magnetic field H. Equations 7.3 and 7.4 describe the coupling between the electric and magnetic fields. (For a complete list of symbols, the reader is referred to the “Notation” section of this chapter.) The interaction of EM waves (e.g., microwaves) with matter is expressed by the material equations or constitutive relations (Eqs. 7.5–7.7), where the dielectric constant ε (the interaction of nonconducting matter with an electric field), the conductivity σ, and the permeability μ (the interaction with a magnetic field) dictate their behavior. Constitutive relations: (7.5) D = ε0 εr ⋅ E (7.6) B = μ 0 μr ⋅ H (7.7) j = σ ⋅E
Chapter 7
Simulating and Measuring Transient Three-Dimensional Temperature Distributions
Where ε0 is the dielectric constant and μ0 the magnetic permeability in free space (vacuum) and εr and μr are their relative values. Generally, all these parameters can be complex tensors; in the case of food materials, some simplifications are possible: food behaves nonmagnetically, therefore the relative permeability can be set to μ = 1 and the permittivity tensor can be reduced to a complex constant with real (ε ′) and imaginary part (ε ″ ), which include the electrical conductivity σ, as shown in Equation 7.8.
σ 2 ⋅ π ⋅ f ⋅ ε0
(7.8)
P = 2 ⋅ π ⋅ f ⋅ ε 0 ⋅ ε r′′⋅ E 2 V
(7.9)
ε r′′ = PV =
Equation 7.9 describes the volumetrically dissipated power PV as function of microwave frequency f, dielectric properties (ε0, ε ″), and the electric field E. Depending on the problem to be modeled, the coupled phenomena can include equations for fluid flow, namely the conservation equations for mass, momentum, and energy (for these equations, refer to other chapters in this book; e.g., Chapter 5). Neglecting mass transfer, a general equation for heat transfer can be described by
ρCP
∂T − ∇ ⋅ (k ⋅∇T ) = −∇qR + Qem ∂t
(7.10)
Here ρ is the density, CP the specific heat capacity, k the thermal conductivity of the materials used in the scenario, qR the radiation power flux density, and Qem the heat source generated by the dissipated microwaves (Qem = PV; Eq. 7.9). The left side of this equation is well known from the traditional equation describing the conduction ∂T of heat ( ρCP = ∇ ⋅ (k ⋅∇T )), and the terms on ∂t the right side were added for heat transfer by radiation and for the heat source by the dielectric losses, respectively (Metaxas 1996). Assuming the product consists of a moist solid material, the radiation term has to be taken into account only at surfaces to gaseous materials, and Equation 7.10 can be simplified to
ρCP
∂T − ∇ ⋅ (k ⋅∇T ) = PV ∂t
133
(7.11)
It has to be noted that the thermophysical properties are generally not constant but dependent on temperature (and moisture content of the food). In microwave modeling, as well as in modeling of any other food process alike, the knowledge of the thermophysical properties of all materials involved in the simulated scenario as function of the changing conditions during processing is imperative for accurate simulation results (see also Chapter 2). Heat transfer and EM equations are coupled extrinsically by the values of the temperature and the EM heat generation and intrinsically by the temperature dependency of the thermophysical material properties. At the product surface, boundary conditions need to take the external heat transfer into account. Boundary conditions for both EM and heat transfer application modes are given in the example in Section 7.4. Although today’s computers have tremendous numerical calculation performance, with respect to processor speed and fast accessible memory, compared with computers some years ago, it is still no match for the full complexity of these models without some simplifications. In the case of pure electromagnetism, commercial numerical software packages are available. A comparison of their potential for microwave heating has been addressed by, for example, Yakovlev (2000, 2006). Some self-developed software codes are also described in literature. Most of them originated from the telecommunication area but were developed further for microwave heating applications (Regier and Schubert 2001). The discretization of the partial differential equations or their corresponding integral equations together with the suitable boundary conditions on a calculation grid is common to all numerical techniques. In practice, the method of finite differences (FDM) and the finite element method (FEM) are most common; however, the method of moments (MOM), the transmission line matrix method (TLM),
134
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
and the boundary element method (BEM) have also been applied. For short bursts of high microwave power densities, the heat transfer component of Equation 7.11 can be neglected, as it is much slower than the microwave heat generation. The temperature rise in a defined volume is then directly proportional to the dissipated microwave power, which can be inferred from the effective electric field value and the dielectric loss factor or the electric conductivity, respectively (see Eqs. 7.8 and 7.9).
ρCP
∂T = PV = 2 ⋅ π ⋅ f ⋅ ε 0 ⋅ ε r′′⋅ E 2 = σ ⋅ E 2 ∂t
(7.12)
Some studies using this approximation can be found, for example, in Fu and Metaxas (1994), Liu et al. (1994), Sundberg et al. (1998), Dibben and Metaxas (1994), and Zhao and Turner (1997). Since the late 1990s, and increasing since the early 2000s, a growing number of papers describe the coupled EM field and thermal model. Examples, covering both one- and two-way couplings of temperature-dependent thermophysical properties, including the heat conduction can be found in Torres and Jecko (1997), Ma et al. (1995), Kopyt and Celuch-Marcysiak (2002, 2003, 2004, 2007), Rabello et al. (2005), Zhao and Turner (2000), Sun et al. (2007), Zhu et al. (2007), Sekkak et al. (1995), Lee et al. (2005), Chen et al. (2008), Rakesh et al. (2009), Tilford et al. (2007), Sabliov et al. (2007), Al-Rizzo et al. (2005), and Cordes et al. (2007). This is by all means no complete list of references of work done on simulating microwave application; however, it is considered to form a good basis for the interested reader. In addition to the heat conduction, heat transport by radiation may be addressed by a ray-tracing algorithm (Haala and Wiesbeck 2000). Since the temperatures (and temperature differences) for most food applications are more moderate in comparison with ceramics sintering, where the latter software code originates from, the radiation term becomes negligible and only heat transport by convection or evaporation has to be taken into consideration. The studies from the above-mentioned examples were mostly based on self-developed (academic)
software codes and lack the comfort of user friendliness, full support by software vendors, and extensive manuals. Therefore, they are predominantly useful for the developers in their academic research rather than being suitable for industrial use. In addition to that, most of them occupy further simplifications, such as using water as food material, constant thermophysical properties, or calculating the temperatures only in one or two dimensions, among others. In this chapter, one example of a validated microwave heating simulation, incorporating the EM waves, their interaction with the food product, heat conduction and free convection on the food surface, with the inclusion of temperature-dependent thermophysical properties (Knoerzer 2006; Knoerzer et al. 2008), will be shown in detail in Section 7.4. Furthermore, an approach for simulating the microwave heating of arbitrarily shaped foods and the control of temperature distributions by feedbackcontrolled simulations will be presented.
7.3. Temperature Measurement (Mapping) Methods in Microwave Fields While simulation tools offer insights into processes, hardly feasible by other means, the full potential of simulations is only tangible after validation. However, this is a very challenging task; the EM fields and temperature distributions are not easily measurable without changing them by the measurement procedure itself. A relatively old bibliography covering different temperature indication methods in microwave ovens can be found in Ringle and Donaldson (1975). This section will present a review on more up-to-date temperature measurement strategies. There are a number of established methods for measuring temperature distributions in EM fields, such as thermocouples, fiber optic thermometers, infrared (IR) thermography, microwave radiometry, and temperature indicators (e.g., liquid crystal foils, thermo paper, and model substances). However, many of these methods have severe disadvantages.
Chapter 7
Simulating and Measuring Transient Three-Dimensional Temperature Distributions
7.3.1. Thermocouples Thermocouples are fabricated from electrical conducting wires made of two different metal alloys. They generate an open-circuit voltage, called the Seebeck effect, or Seebeck voltage, discovered in 1821 (Seebeck 1823), which is proportional to the temperature difference between the hot and reference junctions: ΔU = S ⋅ (Thot − Tref )
(7.13)
Here ΔU is the change in voltage, S is the Seebeck coefficient (dependent on the thermocouple’s metal composition), Thot is the temperature at the hot junction, and Tref is the temperature at the cold/reference junction. Without enormous efforts, conventional thermocouples cannot be used in microwave devices. Their metallic wires cause unacceptable disturbance of the fields, which can lead to destruction of the device, as well as damage to the product caused by arcing and plasma generation. Moreover, the method is invasive and only a poor spatial resolution is achievable; that is, the number of locations where temperatures can be measured is limited.
7.3.2. Fiber Optic Probes The basis of the fiber optic thermometry generally used is the temperature-dependent photoluminescence of optically excited phosphors. The key element of fiber optic probes is the sensor consisting, for example, of a small amount of manganeseactivated magnesium fluorogermanate mounted at the tip of the optical fiber. When the sensor material is excited with blueviolet light, the phosphor exhibits a deep red fluorescence. After the activation pulse, the intensity of fluorescent radiation decays exponentially. The decay time can be directly correlated with the temperature. More information can be found in Knoerzer et al. (2005). While the use of fiber optic sensors overcomes the problem of pronounced interaction with the EM field, the achievable spatial resolution is often not sufficient. Furthermore, the fiber optic thermometers
135
are rather delicate and expensive in comparison with conventional thermocouples.
7.3.3. Model Substances A different approach to determine temperature distributions in microwave-heated products is the use of model substances. These substances change their properties when a certain temperature is reached. Model substances, however, should represent foods with regard to certain properties. For microwave heating scenarios, it can be sufficient that only the dielectric properties match the food properties in a certain temperature interval and at a frequency of 2.45 GHz (Risman et al. 1993). But often (especially at lower microwave powers or longer heating times), it is essential that also the thermal conductivity and the heat capacity of the model food match the values of real foods. The following factors can be temperature dependent and have been used for temperature mapping (Risman et al. 1993): • Texture (or viscosity) • Optical transparency • Melting temperature • Coagulation or solidification • Color change (e.g., by changing of pH value with added indicator) Often gels are used because they are easy to cut and mold to an exact shape. One published method uses the color change of the model substance (Risman et al. 1993), another one the coagulation of contained proteins (Wilhelm and Satterlee 1971). A downside of this approach is the fact that for getting information on the temperature distributions within the product, the samples have to be sliced. This method is described further in Chapter 6.
7.3.4. Infrared Thermography All objects (especially hot ones) emit thermal radiation that is in the visible but also in the ultraviolet as well as infrared portion of the EM spectrum, for example, an incandescent light bulb or the sun. The frequency and thus the intensity of this radiation, caused by vibrating atoms and molecules,
136
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
behaving like Hertz’ dipoles, increases with increasing temperature. Thermal imaging cameras can measure the thermal radiation patterns on the surface of the radiating object, and from the frequencies of the radiation, the actual temperatures can be calculated. IR thermography provides good spatial resolutions and is established for measuring surface temperatures. Online IR sensors provide a reasonably accurate readout of the surface temperature of an object that is in the sensor ’s field of view. However, similar to conventional contact probes, IR sensors comprise metallic components and cannot be placed inside the EM fields of microwave equipment. Measurements are only possible through a shielded window. Therefore, the efficacy of the temperature measurement, which in any case represents only the surface temperature of one part of the heated product, is reduced.
7.3.5. Microwave Radiometry The principle and advantages of microwave radiometry are similar to the IR thermography (Stephan 2004), except that the thermal energy detected and used as basis for temperature estimation is in the microwave frequency range rather than the IR region. As the penetration depth of radiation in the microwave frequency range is significantly higher than in the IR frequency range, temperatures several millimeters below the surface can be measured. The measurement of surface or near-surface temperatures in volumetric heating methods like microwave heating is, as indicated before, not sufficient. Using this technique, the product has to be sliced to obtain information on the entire, inner temperature distribution.
7.3.6. Liquid Crystal Foils and Thermo Paper 7.3.6.1. Liquid Crystal Foils Liquid crystals are organic substances, which exhibit properties of both solid and liquid matter. They scatter incident light selectively, depending on their apparent molecular structure. Each liquid crystal compound possesses a
p Figure 7.1. Helical structure in cholesteric liquid crystals; p: helix pitch length (K. Hiltrop 2005, pers. comm.).
helical structure with a characteristic pitch length p (see Figure 7.1). The helix pitch lengths, which, for example, can be altered by changing temperatures, are in the range of the wavelength of visible light. Therefore, changes in temperature are directly reflected in changes of the liquid crystals’ color. Since the fundamental chemical structure is unaffected by the external stimulus, this change is reversible and a liquid crystal coating can respond repeatedly to the same physical changes. 7.3.6.2. Thermo Paper The basis of using thermo paper as a temperature indicator is its special coating. The active slice of the thermo paper contains temperature sensitive chemicals, the so-called color developer, which starts to melt after reaching a certain temperature and change their appearance from transparent to black. This color change usually happens within seconds of reaching a rated temperature. Liquid crystal foils and thermo paper are also established methods for measuring temperature distributions (Grünewald and Rudolf 1981; Feher 1997). However, both methods also provide only surface temperature information. To get information on the inner temperature of a material, the thermal paper has to be placed at the cross-section of interest. In this case, the method is invasive. Furthermore, the use of thermo paper is limited to providing information on temperatures being above or below a certain temperature.
Chapter 7
Simulating and Measuring Transient Three-Dimensional Temperature Distributions
7.3.7. Magnetic Resonance Imaging Almost all of the problems inherent to the abovementioned approaches can be avoided by using MRI as a tool for temperature measurement (Nott and Hall 1999, 2004; Nott et al. 1999, 2000; Bows et al. 2001; Nott and Shaarani 2003; Knoerzer et al. 2005, 2009). This approach allows for noninvasive threedimensional (3D) measurements of microwaveinduced heating patterns. Since the probe is not required to be in contact with the product, temperatures within any water-containing product can be observed during or after microwave heating without destroying the product. Good spatial resolutions can be achieved not only for surface temperatures but also for temperature distributions throughout the product. The large drawback of this technology is the cost of an MRI tomograph, which exceeds the costs for all devices mentioned above by at least one order of magnitude (i.e., at least 10 times). However, as the MRI temperature mapping technique is superior in performance and 3D resolution to the methods mentioned above, this technique will be presented here in more detail. 7.3.7.1. Basics of Temperature Mapping Using MRI Imaging methods based on the resonant absorption and emission of EM energy by hydrogen nuclei placed in strong magnetic fields (MRI) are well known for their widespread clinical applications. Temperature mapping using MRI is possible as temperature shift leads to a very small shift in the resonance frequency for hydrogen nuclei in water. Nuclear Magnetic Resonance (NMR) Many protons (such as 1H, the hydrogen proton) have a nuclear spin and thus a magnetic moment μ (Figure 7.2). Bringing the nonarranged magnetic moments (Figure 7.3a) in a magnetic field B0 causes an alignment in parallel or antiparallel orientation according to the external magnetic field and, as a result, the magnetization M (Figure 7.3b). (7.14) μ = γ ⋅I
(a)
137
(b)
Figure 7.2. Nucleus spin (a) and magnetic moment (b) of a hydrogen proton.
(a)
(b) → M
B0
Figure 7.3. (a) Nonarranged magnetic moments; (b) alignment of magnetic moments in an external magnetic field.
M = ∑μ
(7.15)
where μ is the magnetic moment, γ is the magnetogyric ratio (constant for 1H), I is the angular momentum, and M is the magnetization. In a macroscopic sample, transverse nuclear magnetization, which precesses around the orientation of the external magnetic field B0 with the same angular frequency ω, may be created with an EM excitation pulse, fulfilling the resonance condition (Eq. 7.16; Figure 7.4). The external magnetic field causes a precession of the transverse magnetization M with the socalled Larmor frequency:
ω L = γ ⋅ B0
(7.16)
138
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
In this equation, ωL is the precession (Larmor) frequency and B0 the external magnetic flux density. This precession induces an AC voltage in the radio frequency (RF) coil, the MR signal, which is directly proportional to the spin density, thus the H (proton) density and the water content. When the RF pulse is switched off, the phase relationship will decay with a characteristic time constant (referred to as T2) and their alignment along the z-axis will relax with a different time constant T1; both those parameters are temperature dependent. A further temperature-dependent parameter measurable by MRI is the self-diffusion coefficient. However, similar to the time constants, this parameter also shows a strong dependence on the composition of the fluid in the food.
B0
Another parameter, basically independent of the composition of the fluid in the food, and measurable by MRI, is referred to as the chemical shift (of the MR frequency). The method of measuring temperatures using this parameter is based on the temperature dependence of the water proton chemical shift: Increasing temperature leads to breaking of hydrogen bonds and thus to a stronger shielding of the hydrogen proton due to a reduced hydrogen– oxygen distance by oxygen-located electron clouds. As a result, the precession frequency decreases, and thus the phase (spin angle) of the MR signal (Δf/ΔT = 0.01 ppm/°C; Hindman 1966). From a measured phase difference between the sample with known initial temperature and the heated sample, the actual temperature can be calculated (Figure 7.5). Spatial resolution is introduced into NMR by a place-to-frequency transformation, where the static magnetic field is varied linearly across the sample with a magnetic field gradient G by using additional coils (Knoerzer et al. 2009).
M(t0) f
M(tp) Y
z y
M(t>tp)
x
Figure 7.4. Schematic representation of inverting the mag netization M (or M ) in the transverse plane.
Phase image at Tref
7.3.7.2. Equipment Basically any commercially available MRI tomograph can be used for performing temperature mapping studies; from large-sized tomographs as used in medical diagnostics for humans (or even larger ones used in veterinary diagnostics) down to small-scale high-resolution tomographs with diameters in the millimeter range. In the validation studies, as outlined in Section 7.4, a Bruker Avance 200 SWB tomograph (Bruker Biospin MRI GmbH, Ettlingen, Germany; Figure
Δ f (Hz) 60
Phase image at T
ΔT (K) 325 320
40
315 20 (a)
(b)
(c)
310 (d)
305 0 Figure 7.5. (a) MRI phase image of a model food at known initial temperature (Tref = const); (b) phase image of heated sample; (c) phase difference distribution (c = a − b); and (d) temperature distribution (calculated from phase difference with knowledge of a chemical shift of Δf/ΔT = 0.01 ppm/°C). See color insert.
Chapter 7
Simulating and Measuring Transient Three-Dimensional Temperature Distributions
(a)
Jacket with liquid nitrogen
Shim unit
139
(b)
Jacket with liquid hydrogen
Gradient unit RF coil
Magnet
Sample holder
Figure 7.6. (a) Schematic representation of an MRI tomography; (b) tomograph used for temperature mapping studies.
7.6) was used. The superconducting magnet with a 150 mm room-temperature bore produces a magnetic flux density of 4.7 T. Spatial resolution is achieved with a Bruker mini0.36 gradient system generating field gradients of up to 0.14 T/m in three orthogonal directions. An open-ended Bruker birdcage probe head with a 64-mm inner diameter was used as an antenna. Pulse sequences were used as provided by Bruker. 7.3.7.3. Method For measuring temperature or phase distribution, respectively, a gradient echo pulse sequence (Kimmich 1997) was used. Temperature distributions were measured in a variable number of slices (from 10 up to 50 slices) perpendicular to the z-axis, with a slice thickness of 1 mm, a 2D resolution of 64 × 64 pixels, which corresponds in the 64-mm birdcage probe to a 3D
resolution of 1 mm3. The overall measuring time was 12.8 s, with an accuracy of approximately ±2 K. The MRI data (binary 3D matrices) obtained were exported and analyzed with self-developed MATLAB 7.0™ (The Mathworks Inc., Natick, MA) programs. To avoid temperature equilibration between heating and measuring temperature distribution in the tomograph, a microwave device was developed together with Gigatherm AG (Grub, Switzerland) (Hermann 2004). This system allows the transmission of microwaves through a circular waveguide into the RF coil (birdcage), where the sample to be investigated is placed (Figure 7.7), making it possible to measure in situ 3D temperature distributions during microwave processing. Heating experiments with differently shaped model food samples and real foods were performed
140
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
appr. 2.5 m
rectangular waveguide
microwave generator
circular waveguide
magnet
sample
RF coil / birdcage
waterload
Figure 7.7. Sketch of the device for introducing microwaves into the MRI tomograph.
and temperature changes at discrete points measured by MRI were quantitatively validated using fiber optic thermometry (Knoerzer et al. 2009).
7.4. Examples of Validated Microwave Heating Models This section presents the simulation approach developed by Knoerzer et al. (2008). The methodology is based on a user-friendly interface coupling two commercial software packages to model timedependent temperature profiles not only of microwave treated products with simple shapes but also of arbitrarily shaped products in three dimensions. Validation of the model was performed using noninvasive MRI, allowing for measuring temperature distributions during the running process in three dimensions. With the coupled model, hot and cold spots in the products can be detected to test appropriate microwave treatment control strategies. A further feature of the model describes a feedback control loop in the simulation, which is used to optimize the microwave process conditions (pulse profile) to allow minimal time/temperature treatments and improved uniform temperature distributions.
7.4.1. Model Geometry The geometry of the model microwave cavity is depicted in Figure 7.8b. The model was designed in full 3D to be a good approximation of the microwave chamber in the equipment as outlined in the previous section (h = 300 mm, d = 84 mm). Samples used were predominantly simple shapes (cylinders, spheres) of a model food with known temperature-dependent thermophysical properties (Knoerzer et al. 2004). However, a method was developed to allow the introduction of models of real food structures based on a 3D spin density measurement technique (Knoerzer 2006) as shown in Figure 7.9.
7.4.2. Process, Initial, and Boundary Conditions 7.4.2.1. Process Conditions In the uncontrolled microwave heating simulation of model food cylinders, the microwave power was set to constant values of P = 19 and 23.1 W between t = 200 and 650 s, and to P = 0 at all other times. In the feedbackcontrolled simulation, the microwave power was set to 37 W as long as the temperature in the hottest spot
Chapter 7
Simulating and Measuring Transient Three-Dimensional Temperature Distributions
(a)
141
(b)
appr. 2.5 m
rectangular waveguide
microwave generator
circular waveguide sample
magnet birdcage
waterload simulated area
Figure 7.8. (a) Sketch of microwave device for introducing microwaves into MRI tomograph and (b) depiction of area of interest in the simulation process.
was below the predefined maximum temperature of 343 K, and set to P = 0 when this temperature was exceeded. A stop condition was triggered when the temperature in the coldest spot is equal or greater than the predefined target temperature (333 K) for a predefined time of 30 s. 7.4.2.2. Initial Conditions At the start of the process, both sample and surrounding air are in thermal equilibrium at T0 = 298 K. In the feedbackcontrolled simulation, the initial temperature and the temperature of the surrounding air was set to T0 = 295 K for the “pure” microwave heating process. In the combined microwave–hot air heating process, the initial temperature was also 295 K, whereas the air temperature was set to the target temperature of 333 K. 7.4.2.3. Boundary Conditions The boundary conditions for the EM interaction with the surface of the sample are described by reflection and transmission.
The boundary of the cavity is assumed to be a perfect conductor and thus (7.17) E × n = 0 and H ⋅ n = 0 Here n is the normal vector to the surface. The boundary conditions at an interface between two dielectric materials are E2 − E1 × n = 0 (7.18) ε 2 E2 − ε1 E1 ⋅ n = 0 (7.19) H 2 − H1 × n = 0 (7.20) μ2 H 2 − μ1 H1 ⋅ n = 0 (7.21)
(
(
(
)
(
)
)
)
A heat transfer based on free convection on the boundary of the heated object (∂V) was modeled for thermal interactions. −k
∂T + h ⋅ (T − Ta ) = 0 on ∂V ∂n
(7.22)
The heat transfer coefficient was calculated taking thermal conductivity of the surrounding medium
142
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
(a) 50
25
0 50
25
0
0
50
25
50 25 (c)
(b) 0 50
50
25
0 0
50
50
25
25
0
25
0 50
25
0
0
25
50
50
25
0
0
25
50
Figure 7.9. The inner structure of the chicken wing as determined by MRI (middle: MRI raw data; corners: matrix subdivided into (a) bones, (b) fat, and (c) meat).
and shape of the sample into consideration (VDI Wärmeatlas 2002). A good approximation for the heat transfer coefficient was found to be h=
kair r
(7.23)
with the thermal conductivity of the surrounding air (kair) and an average radius ( r ) of the sample with H/d (height-to-diameter ratio) between 0.7 and 1.3.
7.4.3. Material Properties The EM and thermal properties, that is, loss factor ε ″, dielectric constant ε ′, thermal conductivity k, density ρ, and heat capacity CP, and their variation with water content and temperature were determined experimentally for a model food, developed for microwave heating research, and fitted with thirdorder polynomials (Knoerzer et al. 2004). These equations were implemented as material properties in the respective subdomains in the software packages used.
Chapter 7
Simulating and Measuring Transient Three-Dimensional Temperature Distributions
In the case of the chicken wing heating, thermophysical properties of fat, meat, and bone material were taken from literature (as constants).
7.4.4. Computational Methods The partial differential equations describing the EM part of the model were solved with the finite difference time domain (FDTD) method using QuickWave-3D™ (QWED Sp. z o.o., Warsaw, Poland). FEM was chosen for the calculations of heat generation and conduction and solved using COMSOL Multiphysics™ (COMSOL AB, Stockholm, Sweden). The interface between both software packages was developed in MATLAB 7.4™ (The Mathworks Inc.). The cross-software communication was enabled by transforming the different output formats (text files from QuickWave-3D™ and structural arrays from COMSOL Multiphysics™ into MATLAB matrices containing the data (see flowchart in Figure 7.10). Although the QuickWave3D™ and COMSOL Multiphysics™ are based on very different numerical schemes and associated different meshes, the data provided by the solvers could be transformed into MATLAB matrices by interpolation and in MATLAB defined as locationand time-dependent functions, for example, PV = f(x,y,z,t). A graphical user interface (GUI) was programmed to allow users not familiar with MATLAB to run the simulations. The software interface uses the data provided in the GUI to allocate material properties (see Section 7.4.3) and process conditions (e.g., microwave frequency, pulse duration, initial and external temperatures, among others) to predefined geometries in both QuickWave-3D™ and COMSOL Multiphysics™. Another option in the GUI is to define geometrical properties of simple shapes (e.g. cylinders, cubes, spheres) with subsequently solving the model. The presented approach describes a one-way simulation, that is, after calculating the dissipated power by QuickWave-3D™ with constant dielectric properties, the heat transfer is calculated with temperature- and location-dependent properties. Following Equations 7.9 and 7.12, PV is directly
143
proportional to the loss factor ( PV ∝ ε ′′ ), and thus, a modified form can be used to take the dependency of the dielectric properties and, thus, the dissipated power into consideration. PV (T , x, y, z ) = PV ,QuickWave −3 D ( x, y, z ) ⋅
ε ′′(T , x, y, z ) ε initial ′′ (7.24)
In Equation 7.24, PV,QuickWave-3D is the solution of the EM simulation, ε initial ′′ is the initial loss factor of the sample, and ε″(T,x,y,z) is the recalculated loss factor taking different temperatures at different locations in the sample into account. A self-developed MATLAB 7.4™ code was used to transform the structure data of real foods as determined by MRI into the format readable by the simulation software packages and allocating the corresponding material properties. Different materials yield different intensities in MRI spin density measurements, making it possible, by multithreshold setting, to subdivide a full 3D MRI image (3D matrix) into different matrices corresponding to the materials and allocate the matching thermophysical properties at the specific locations to these materials. Figure 7.9 represents such a matrix subdivided into submatrices, and Figure 7.10 represents the procedure of simulating the microwave heating of this food product. A further code was developed in MATLAB 7.4™ to allow for a feedback-controlled simulation. This code is capable of identifying hottest and coldest spots in the simulated heating scenario. After a predefined maximum temperature in the hot spot is reached, the dissipated power is set to zero, and then back to the predictions from QuickWave-3D™ once the hot spot temperature is falling below that value, according to the description in Section 7.4.2.1. Once the predefined temperature is reached and held for a certain time, a stop command is triggered and the resulting pulse profile (as shown in Figure 7.19) stored. In QuickWave-3D™, the computational domain was subdivided into cubic elements with 1-mm edge length (corresponding to 1.5 million cells), so that at least 15 elements per wavelength also inside the product are achieved to ensure grid independence of
Interface – complete simulation controlled by one GUI
(a)
QuickWave-3D TM – simulates the power dissipation
COMSOL TM – solves the energy balance y-dim./ × 10 m 0.060.04 5 0.02 0 TM 4 COMSOL 0.06 – Input 3 0.04 2 0.02 cube with 1 size of 0 0.04 0.06 MRI 0 0 0.02 martix x-dim./m
chicken wing water load
(b)
50 25
0 y-d 50 im 25 0 0 ./m m
z-dim./m
QuickWave -3DTM – Output
waveguide
pv/Wmm3
e′, e″ = const
z-dim./mm
–4
25 50
x-dim./mm
(c)
T/K
z-dim./mm
Interface – calculation of 3D temperature distribution as function of time solution at discrete time: theating = 400 s, PMW = 25 W, matrix size = 643 mm3 340 335 60 330 50 325 40 320 30 315 310 20 305 10 300 0 295 50 50 00 y-dim ./mm m m ./ x-dim (d) Figure 7.10. Example of flowchart of the simulation (with QuickWave-3D™ and COMSOL Multiphysics™ solution): microwave heating of a chicken wing. (a) GUI allowing communication with the interface controlling both QuickWave-3D™ and COMSOL Multiphysics™; (b) QuickWave-3D™ model; (c) COMSOL Multiphysics™ structure; (d) solution of coupled EM thermal solver.
144
Chapter 7
Simulating and Measuring Transient Three-Dimensional Temperature Distributions
the predictions; the mesh in COMSOL Multiphysics™ was automatically generated and the number of mesh elements increased until no further noticeable change in model predictions could be observed. The number of elements was dependent on the size of the sample and the material properties and varied between 9,000 and 20,000 tetrahedral elements. A workstation with a dual-core processor (CPU speed 2.6 GHz) and RAM of 2 GB running a 32-bit Windows XP professional OS was used, which allowed the simulation to be completed within less than 2 h. Depending on the number of pulses needed to achieve the desired temperature distribution in the controlled simulations, the overall solution time of the model increased accordingly.
7.4.5. Validation of the Simulation Initial validation was performed qualitatively by visually comparing simulated and measured 3D temperature distributions results. Then, measured temperature profiles at selected points (the hot and cold spots) were compared with profiles predicted by the coupled model at the same locations for quantitative validation. Furthermore, a software algorithm was developed to extract measured and simulated temperature distributions from the 3D output matrices (from both the MRI measurements and the coupled models) in axial cross-sections at
discrete times. The temperature values at all locations in the resulting 2D matrices were used to obtain parity plots. The routine was also programmed to perform a statistical analysis by calculating the coefficient of determination R2 as a measure of accuracy of the model predictions.
7.4.5.1. Visual Comparison of 3D Temperature Distributions Figure 7.11 shows both simulated and measured 3D temperature distributions in a microwave-heated model food cylinder at a discrete time of 250 s and a microwave power of 19 W. Figures 7.12 and 7.13 provide a close-up view of two cross-sections of the cylinder; one in the middle (h = 16 mm) of the cylinder, the second one near the top (h = 26 mm). A good qualitative agreement of simulation and measurement was found for all modeled scenarios, with the slices from both simulation and MRI measurement showing very similar temperature distribution profiles. 7.4.5.2. Comparison of Temperature Profiles in Discrete Points (Hot and Cold Spots) Figures 7.14 and 7.15 show predicted and measured temperature profiles in the hot and cold spots of one slice (h = 16 mm) of the heated model food cylinder at microwave powers of 19 and 23.1 W, respectively.
T (K) 310
14
30 simulation
25 20
12
measurement
308
10 306
z (mm)
8 slices
15 10 5 0 60 40 x (mm
)
40 30 20 y (mm)
145
6
304
4 2 0 50 30 x (mm 20 )
302 60 40 y (mm)
300
Figure 7.11. Visual comparison between the simulated (left) and the measured (right) heating of a model food cylinder (at a discrete time): PMW = 19 W; t = 250 s; Text = 298 K. See color insert.
T (K) 308
306
304
302 simulation measurement Figure 7.12. Visual comparison between the simulated (left) and the measured (right) heating of the center cross-section (h = 16 mm) of the microwave-heated model food cylinder (at a discrete time). See color insert. T (K) 308
306
304
302 simulation measurement Figure 7.13. Visual comparison between the simulated (left) and the measured (right) heating of a cross-section near the top (h = 26 mm) of the microwave-heated model food cylinder (at a discrete time). 340
hot spot measured cold spot measured hot spot simulated cold spot simulated
335 330
hot spot
temperature (K)
325 320 315 310 cold spot 305 300 295
0
200
400
600
800
1000
time (s) Figure 7.14. Comparison of temperature profiles in a hot and a cold spot in a microwave-heated cylindrical model food sample (microwave power PMW = 19 W).
146
Chapter 7
Simulating and Measuring Transient Three-Dimensional Temperature Distributions
hot spot measured cold spot measured hot spot simulated cold spot simulated
340
147
hot spot
temperature (K)
330
320
cold spot
310
300 0
200
400
600
800
1000
time (s) Figure 7.15. Comparison of temperature profiles in a hot and a cold spot in a microwave-heated cylindrical model food sample (microwave power PMW = 23.1 W).
Good quantitative agreement was found in all cases.
7.4.6. Simulated Heating of a Chicken Wing The simulated heating of the chicken wing, described in Section 7.4.1 and shown in Figure 7.10 was performed at a microwave power of 25 W for 600 s. Figure 7.17 shows the temperature distribution in the chicken wing after heating. It is obvious that uncontrolled process conditions lead to the
350 s 600 s bisecting line
80 temperature (predicted) (°C)
7.4.5.3. Comparison of Cross-Sections Figure 7.16 shows a confidence (parity) plot of simulated versus measured temperatures at different times of the heating process at identical locations of a crosssection of the microwave-treated sample. A statistical analysis showed a coefficient of determination R2 greater than 0.95, which means measurement and prediction are in good agreement.
100
60
40
20
0 0
20
40 60 80 temperature (measured) (°C)
100
Figure 7.16. Confidence (parity) plot of simulated temperatures versus measured temperatures of identical locations of the axial cross-section where the hottest spot is located.
148
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
development of unacceptably uneven temperature distributions caused by the microwave specific factors described earlier and in detail in Ringle and Donaldson (1975), Knoerzer (2006), WäpplingRaaholt and Ohlsson (2005), Ryynänen et al. (2004), Risman (1992), Sinell (1986); Ohlsson and Bengtsson (2001), and Buffler (1993).
z-dimension (mm)
T (K) 350 60
340
50
330
40
320
30 20
310
10 t = 800 s 0 60 40 x-dimen s
60 20 40 m) 20 0 0 n (m io s n e im ion (mm y-d )
300
Figure 7.17. 3D temperature distribution in a chicken wing after microwave treatment of 600 s (power was switched on after 200 s) as calculated using the new simulation procedure (flowchart in Figure 7.10). See color insert.
7.4.7. Controlled Microwave Heating of a Model Food Cylinder In modeled microwave heating scenarios, 3D temperature distributions are clearly defined at any point in time. This fact allows a feedback algorithm to control the process conditions (microwave power) in the simulated scenarios based on identifying and evaluating the hottest and coldest spot in the heated product. Such algorithms can then predict the timedependent process conditions needed to ensure the most uniform heating achievable. In practice, such a feedback control loop is difficult to accomplish in a real-life industrial microwave process, as temperature distributions have to be measured inline. Figure 7.18 shows the temperature profiles in the hottest and the coldest spot in a microwave-heated cylindrical model food sample. The microwave power was set to P = 37 W as long as the temperature in the hot spot was below the maximum temperature, and to P = 0 as soon as this temperature was exceeded. The maximum product temperature was set to 343 K, whereas a required minimum temperature of 333 K was to be reached and held for 30 s.
Figure 7.18. (a) Pure microwave heating (PMW = 37 W; external temperature Text = 295 K); (b) combined microwave–hot air heating (PMW = 37 W; Text = 333 K).
Chapter 7
Simulating and Measuring Transient Three-Dimensional Temperature Distributions
Figure 7.18a shows the example of a “pure” microwave heating; that is, the temperature outside the product was set to the initial temperature of the sample (T = 295 K). Figure 7.18b shows a combined microwave–hot air process; that is, the temperature inside the microwave oven was set to the target temperature (T = 333 K). In the case of the microwave heating alone, the maximum temperature was reached and regulated after about 200 s. However, the temperature in the coldest spot (which was found at the product surface) did not reach the target temperature, even after more than 20 minutes. The reason for this is the heat loss from the heated sample to the cooler surrounding air. When hot air is introduced in the combined process, the temperature in the hot spot again reaches maximum temperature after about 200 s. In this particular case, the temperature in the coldest spot reached the target temperature after about 10 minutes. The combined process therefore enables safe minimal time/temperature treatments. The output of the feedback-controlled simulation is shown in Figure 7.19, a microwave power pulse program that can be used in the control unit of a microwave oven and, thus, allows for repeating the
40 35
power (W)
30 25 20 15 10 5 0
0
100
200
300 400 time (s)
500
600
Figure 7.19. Output of the on/off control tool; microwave power pulse program (example of combined microwave–hot air heating as described above).
149
simulated scenario in reality by controlling or setting (no feedback) the microwave power.
7.5. Summary, Conclusions, and Outlook Microwaves heat food volumetrically and more rapidly than conventional heating methods. However, several microwave intrinsic factors associated with volumetric heating can (and most certainly will if microwave power is supplied continuously into a solid food product) lead to the development of nonuniform temperature distributions, with edge and corner overheating, as well as the development of hot and cold spots within the product. Over the last decades, research in microwave processing pushed toward the successful development of computational models to accurately predict the process, yielding 3D temperature distributions. Approaches to achieve this challenging goal varied from very simplified models to sophisticated models coupling computational fluid dynamics with solvers for EM problems. Since the early 2000s, a growing number of articles describe this coupling. In this chapter, one successfully validated simulation was described in detail, accurately predicting temperature profiles during a heating process in a lab-scale microwave system. The one-way coupling, enhanced by an approach to implement the temperature-dependent loss factor and thus dissipated power into the energy balance is computationally convenient and very time efficient compared with a two-way coupling. However, it has to be mentioned that software packages capable of performing two-way coupling are available today, which are based on FTDT and therefore superior in efficiency to codes based on FEM. The presented software procedure simulates both EM waves and heat transfer and therefore the temperature evolution in arbitrarily shaped foods. While simulation tools offer insights into processes that are hardly feasible by other means, the full potential of simulations is only tangible after validation. As described earlier, in the case of microwave processing, this is a rather challenging task, as most probes commonly used for measuring temperatures, such as thermocouples, fiber optic probes, or
150
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
thermal IR imaging, either interact with the microwave field or yield only poor spatial resolution. To date, there is only one methodology that provides the same data as the model, that is, transient 3D temperature distributions. This MRI methodology was highlighted in this chapter and used for validating the simulated scenario by introducing microwaves into the MRI probe where the food product was held. As shown by both the simulated predictions and the MRI measurements, significant temperature heterogeneities occurred as long as the treatment was uncontrolled, while more uniformity was achieved when a control tool was implemented in the simulation. This kind of feedback-controlled simulation is one-of-a-kind to date and allows for predicting optimal power programs, ensuring safe minimal time–temperature treatments in microwave food processing. Simulations of this type can be used both for equipment and process design and optimization. Furthermore, they will greatly assist in demonstrating the safety of the process for industry and regulatory bodies.
P PMW PV PV,QuickWave-
Notation
ε0
Latin Letters B
Magnetic flux (density)
CP D d e E f G
Specific heat capacity Electric flux density Diameter Euler ’s number Electric field Frequency Magnetic field gradient
h, H h H I j k M, M n p
Height Heat transfer coefficient Magnetic field Nuclear spin Electric current density Thermal conductivity Magnetization Normal to the surface Pitch length of helical liquid crystal structure
T = V · s/ (A · m) J/(kg ·K) A · s/m2 m ≈2.71828 V/m Hz, 1/s T/m = V·s/ (A·m2) m W/(m2 · K) A/m kg · m2/s A/m2 W/(m · K) A/m — m
3D
Qem qR R2 S1 T Tref T1, T2
t U V x,y,z
Power Microwave power Power density Power density calculated by QuickWave-3D™ Electromagnetic heat source Radiation power flux density Coefficient of determination Signal intensity of luminescence Temperature Reference temperature Transversal and longitudinal relaxation times Time Voltage/potential Volume Spatial coordinates
W = J/s W = J/s W/m3 W/m3 W/m3 W/(m2 · s) — arb. units K, °C K, °C s
s V m3 m
Greek Letters
εr ε εr′ εr″ Φ μ0
Dielectric constant of vacuum Relative dielectric constant Complex dielectric constant Real part of complex permittivity Imaginary part of complex permittivity, dielectric loss factor Magnetization inversion angle Permeability of vacuum
μr, μ Relative magnetic permeability Magnetic moment μ π Ludolph’s number, circular constant ρ Charge density ρ Mass density σ Conductivity τ Decay time
8.854 · 10−12 A · s/(V · m) — — —
— ° = 1/ε 0c20 = 1.257 · 10−6 V·s/(A·m) — A · m2 ≈ 3.14159 A · s/m3 kg/m3 S/m s
Chapter 7
Simulating and Measuring Transient Three-Dimensional Temperature Distributions
γ
Magnetogyric ratio
ω ωL
Angular frequency Larmor frequency
Hz/T = m2/ (V· s2) Hz = 1/s Hz = 1/s
Operators ∂ ∇ ∑ Δ ∇⋅ ∇×
Partial differential Nabla operator Sum Difference Divergence Curl
Abbreviations 2D 3D AC BEM CAPE CPU EM FDM FDTD FEM FPA GUI IR LED MOM MR MRI NMR OS pixel ppm RAM RF TLM
Two-dimensional Three-dimensional Alternating current Boundary element method Computer-aided process engineering Central processing unit Electromagnetic Finite difference method Finite difference time domain Finite element method Focal plane array Graphical user interface Infrared Light-emitting diode Method of moments Magnetic resonance Magnetic resonance imaging Nuclear magnetic resonance Operation system Picture element Parts per million Random access memory Radio frequency Transmission line matrix
References Al-Rizzo HM, Tranquilla JM, Feng M. 2005. A finite difference thermal model of a cylindrical microwave heating applicator
151
using locally conformal overlapping grids: Part I—Theoretical formulation. J Microwave Power Electromagn Energy 40(1): 17–30. Bows JR, Patrick ML, Nott KP, Hall LD. 2001. Three-dimensional MRI mapping of minimum temperatures achieved in microwave and conventional food processing. Int J Food Sci Technol 36:243–252. Buffler CR. 1993. Microwave Cooking and Processing: Engineering Fundamentals for the Food Scientist. New York: AVI Book. Chen H, Tang J, Liu F. 2008. Simulation model for moving food packages in microwave heating processes using conformal FDTD method. J Food Eng 88(3):294–305. Cordes BG, Eves EE, Yakovlev VV. 2007. Modeling-based minimization of time-to uniformity in microwave heating systems. Proceedings 11th AMPERE Conference on Microwave and High Frequency Heating (Oradea, Romania, September 2007), 305–308. Decareau RV. 1985. Microwaves in the Food Processing Industry. Orlando, FL: Academic Press Inc. Dibben DC, Metaxas AC. 1994. Finite-element time domain analysis of multimode application using edge elements. J Microwave Power Electromagn Energy 29(4):242–251. Feher LE. 1997. Simulationsrechnungen zur verfahrenstechnischen Anwendung von Millimeterwellen für die industrielle Materialprozesstechnik. Wissenschaftliche Berichte FZ KA 5885. Karlsruhe: Forschungszentrum Karlsruhe. Fu W, Metaxas AC. 1994. Numerical prediction of threedimensional power density distribution in a multi mode cavity. J Microwave Power Electromagn Energy 29(2):67–75. Grünewald TH, Rudolf M. 1981. Messung der Temperatur und der Temperaturverteilung im Mikrowellenfeld. Zeitschrift für die Lebensmittelwirtschaft 32(3):85–88. Haala J, Wiesbeck W. 2000. Simulation of microwave, conventional and hybrid ovens using a new thermal modelling technique. J Microwave Power Electromagn Energy 35(1): 34–43. Hermann A. 2004. Aufbau und Inbetriebnahme einer Vorrichtung zur Einkopplung von Mikrowellen in einen NMRTomographen. Diplomarbeit: Universität Karlsruhe (TH). Hindman JC. 1966. Proton resonance shift of water in gas and liquid states. J Chem Phys 44:4582–4592. Kimmich R. 1997. NMR-Tomography-Diffusometry-Relaxometry. Berlin: Springer. Knoerzer K. 2006. Simulation von Mikrowellenprozessen und Validierung mittels bildgebender magnetischer Resonanz. Dissertation, Universität Karlsruhe (TH). Knoerzer K, Regier M, Erle U, Schubert H. 2004. Development of a model food for microwave processing and the prediction of its physical properties. J Microwave Power Electromagn Energy 39(3–4):167–177. Knoerzer K, Regier M, Schubert H. 2005. Measuring temperature distributions during microwave processing. In: H Schubert, M Regier, eds., The Microwave Processing of Foods. Cambridge: Woodhead Publishing Ltd.
152
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Knoerzer K, Regier M, Schubert H. 2008. A computational model for calculating temperature distributions in microwave food applications. Innov Food Sci Emerg Technol 9(3):374–384. Knoerzer K, Regier M, Hardy EH, Schuchmann HP, Schubert H. 2009. Simultaneous microwave heating and three-dimensional MRI temperature mapping. Innov Food Sci Emerg Technol 10(4):537–544. Kopyt P, Celuch-Marcysiak M. 2002. Review of numerical methods for solving heat conduction coupled to conformal electromagnetic FDTD solver. European Symposium Numerical Methods in Electromagnetics (JEE ‘02), Toulouse, March, 140–145. Kopyt P, Celuch-Marcysiak M. 2003. Coupled electromagnetic and thermal simulation of microwave heating process. 2nd International Workshop on Information Technologies and Computing Techniques for the Agro-Food Sector, Proceedings, Barcelona, November–December, 51–54. Kopyt P, Celuch-Marcysiak M. 2004. Coupled FDTDFEM approach to modelling of microwave heating process. Proceedings of the 5th International Conference on Computation in Electromagnetics (CEM 2004), Stratford-uponAvon, April. Kopyt P, Celuch-Marcysiak M. 2007. Coupled electromagnetic thermodynamic simulations of microwave heating problems using the FDTD algorithm. J Microwave Power Electromagn Energy 41(4):18–29. Lee HK, Li BQ, Huo Y, Tang J. 2005. Validation of 3-D electromagnetic-thermal model for microwave food processing. Ht2005: Proceedings of the ASME Summer Heat Transfer Conference 2005, Vol 3, 781–786. Liu F, Turner I, Bialkowski M. 1994. A finite difference time domain simulation of power density distribution in a dielectric loaded microwave cavity. J Microwave Power Electromagn Energy 29(3):138–148. Ma L, Paul DL, Pothecary N, Railton C, Bows JR, Barrat L, Mullin J, Simons D. 1995. Experimental validation of a combined electromagnetic and thermal FDTD model of a microwave heating process. IEEE Trans Microwave Theory Tech 43(11):2565–2571. Maxwell JC. 1865. A dynamical theory of the electromagnetic field. Phil Trans Royal Soc London Ser B Biol Sci 155:459–512. Metaxas AC. 1996. Foundations of Electroheat. Chichester: John Wiley & Sons. Metaxas AC, Meredith RJ. 1983. Industrial Microwave Heating. London: Peter Peregrinus Ltd. Mudgett RE. 1986. Microwave properties and heating characteristics of foods. Food Technol 40:84–93, 98. Nott KP, Hall LD. 1999. Advances in temperature validation of foods. Trends Food Sci Technol 10(11):366–374. Nott KP, Hall LD. 2004. Measurement of temperature and other heat induced changes in foods by magnetic resonance imaging (MRI). ICEF9—9th International Congress on Engineering and Food, Montpellier, France.
Nott KP, Shaarani SM. 2003. The effect of microwave heating on potato texture studied with magnetic resonance imaging. Magnetic Resonance in Food Science, Latest Developments, Proceedings, Paris, 38–45. Nott KP, Hall LD, Bows JR, Hale M, Patrick ML. 1999. Threedimensional MRI mapping of microwave induced heating patterns. Int J Food Sci Technol 34:305–315. Nott KP, Hall LD, Bows JR, Hale M, Patrick ML. 2000. MRI phase mapping of temperature distributions induced in food by microwave heating. Magn Reson Imaging 18:69–79. Ohlsson T, Bengtsson NE. 2001. Microwave technology and foods. Adv Food Nutr Res 43:65–140. Rabello AA, Silva EJ, Saldanha RR, Vollaire C, Nicolas A. 2005. Adaptive time-stepping analysis of nonlinear microwave heating problems. IEEE Trans Magn 41(5):1584–1587. Rakesh V, Datta AK, Amin MHG, Hall LD. 2009. Heating uniformity and rates in a domestic microwave combination oven. J Food Process Eng 32(3):398–424. Regier M, Schubert H. 2001. Microwave processing. In: P Richardson, ed., Thermal Technologies in Food Processing, 179–207. Boca Raton: CRC Press. Ringle EC, Donaldson DB. 1975. Measuring electric field distribution in a microwave oven. Food Technol 29(12):46–54. Risman PO. 1992. Metal in the microwave oven. J Microwave Power Electromagn Energy 13(1): 28–33. Risman PO, Ohlsson T, Lingnert H. 1993. Model substances and their use in microwave heating studies. SIK Rep 588: 1–10. Ryynänen S, Risman PO, Ohlsson T. 2004. Hamburger composition and microwave heating uniformity. J Food Sci 69(7): M187–M196. Sabliov CM, Salvi DA, Boldor D. 2007. High frequency electromagnetism, heat transfer and fluid flow coupling in ANSYS multiphysics. J Microwave Power Electromagn Energy 41(4):5–17. Schubert H, Regier M. 2005. The Microwave Processing of Foods. Cambridge, UK: Woodhead Publishing Ltd. Seebeck TJ. 1823. Magnetische Polarisation der Metalle und Erze durch Temperaturdifferenz. Berlin: Abhandlung der Akademischen Wissenschaften. Sekkak A, Pichon L, Razek A. 1995. 3-D non linear modelling of microwave heating process using finite element method. Electric and Magnetic Fields—From Numerical Models to Industrial Applications, 99–102. Sinell HJ. 1986. Der Einfluss der Mikrowellenbehandlung auf Mikroorganismen im Vergleich zur konventionellen Hitzebehandlung. DFG-Abschlussbericht Si/55:24–21. Stephan KD. 2004. Continuous non-contact remote temperature sensing during microwave heating with microwave radiometry. 38th Annual Microwave Symposium, Proceedings, Toronto, Canada, July 14–16. Sun H, Zhu HM, Feng HD, Xu L. 2007. Thermoelectromagnetic coupling in microwave freeze-drying. J Food Process Eng 30(2):131–149.
Chapter 7
Simulating and Measuring Transient Three-Dimensional Temperature Distributions
Sundberg M, Kildal PS, Ohlsson T. 1998. Moment method analysis of a microwave tunnel oven. J Microwave Power Electromagn Energy 33(1):36–48. Tang ZW, Mikhaylenko G, Liu F, Mah JH, Pandit R, Younce F, Tang JM. 2008. Microwave sterilization of sliced beef in gravy in 7-oz trays. J Food Eng 89(4):375–383. Tilford T, Baginski E, Kelder J, Parrot K, Pericleous K. 2007. Microwave modeling and validation in food thawing applications. J Microwave Power Electromagn Energy 41(4):30–45. Torres F, Jecko B. 1997. Complete FDTD analysis of microwave heating processes in frequency-dependent and temperaturedependent media. IEEE Trans Microwave Theory Tech 45(1):108–117. VDI Wärmeatlas. 2002. 9 Auflage. Dusseldorf: Springer. Wäppling-Raaholt B, Ohlsson T. 2005. Improving the heating uniformity in microwave processing. In: H Schubert, M Regier, eds., The Microwave Processing of Foods. Cambridge: Woodhead Publishing Limited. Wilhelm MS, Satterlee LD. 1971. A 3-dimensional method for mapping microwave ovens. Microwave Energy Appl Newsl 4(5):3.
153
Yakovlev VV. 2000. Comparative analysis of contemporary EM software for microwave power industry. In: Microwaves: Theory and Applications in Material Processing V. Ceramic Transactions, Vol. 111, 551–558. Westerville, OH: The American Ceramic Society. Yakovlev VV. 2006. Examination of contemporary electromagnetic software capable of modeling problems of microwave heating. In: M. Willert-Porada, ed., Advances in Microwave and Radio Frequency Processing, 178–190. Springer Verlag. Zhao H, Turner I. 1997. A generalised finite-volume time-domain algorithm for microwave heating problems on arbitrary irregular grids. 13th Annual Review of Progress in Applied Computational Electromagnetics, Monterey, CA, USA, 352–359. Zhao H, Turner IW. 2000. The use of a coupled computational model for studying the microwave heating of wood. Appl Math Model 24(3):183–197. Zhu J, Kuznetsov AV, Sandeep KP. 2007. Mathematical modeling of continuous flow microwave heating of liquids (effects of dielectric properties and design parameters). Int J Thermal Sci 46(4):328–341.
Chapter 8 Multiphysics Modeling of Ohmic Heating Peter J. Fryer, Georgina Porras-Parral, and Serafim Bakalis
8.1. Introduction Thermal processing of foods is governed by the need to achieve the required level of sterility without overprocessing the material to the point where nutritional and organoleptic quality is unacceptably diminished. Uniformity of process is key: If it were possible to give all of the food material the same process over the same time, it would be possible to produce a material that had uniform levels of sterility and product quality. In applications where hightemperature short-time (HTST) processing is possible, food products with improved quality can be produced because the reactions that lead to microbial destruction have higher activation energies than those that result in quality loss; with appropriate heat exchangers, it is possible to produce high-quality single-phase products while heating and cooling at several degrees Celsius per second. This approach is, however, limited in its applicability to multiphase foods because of the time required to conduct heat to and from the centers of particles during a process. Conduction heating limits the timescale over which processing of solids can occur as conduction is a much slower process compared with what is possible using convective mixing.
As shown in Figure 8.1, for particles >1 cm, process times are in the order of minutes rather than seconds. This limits the timescale of processing and thus the quality level of the food that can be achieved. In practice, conventionally cooked solid–liquid mixtures are limited in the process temperatures that can be used because excessive heating of the liquid may occur while the solids have still not reached the target temperature. “Ohmic”—or “direct resistance”—heating is one of the alternative thermal processes that have been proposed based on volumetric heat generation; that is, heat is generated locally within the material rather than transferred in from outside. An electric potential is applied across the food, and current flows through the three-dimensional (3D) food matrix, which will usually be a solid–liquid mixture of a sort that cannot be processed quickly by other methods. Heat is generated as a consequence of the passage of electric current through the material. Ohmic heating has a long history, much of which is discussed by de Alwis and Fryer (1990a); electrical pasteurization of milk was quite widespread in the United States in the 1930s, and a number of processes have been developed over the last 100 years. Interest in the process over the last 25 years was spurred by
Innovative Food Processing Technologies: Advances in Multiphysics Simulation, First Edition. Edited by Kai Knoerzer, Pablo Juliano, Peter Roupas, and Cornelis Versteeg. © 2011 by John Wiley & Sons, Ltd. and Institute of Food Technologists. Published by John Wiley & Sons, Ltd. ISBN: 978-0-813-81754-5
155
156
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
100 90
T (°C)
80 70
As already discussed in this book, there are a number of types of volumetric heating processes:
1 cm 2.5 cm 5 cm 10 cm
60 50 40 30 20 –2 10
10–1
100 101 Time (minute)
102
103
Figure 8.1. Conduction heating of spheres of diameters 1–10 cm, initially at 20°C, immersed in a fluid at 100°C, showing different thermal responses.
the development of a process by Capenhurst in the United Kingdom, later commercialized by APV Baker. This process incorporated continuous flow through pipework connecting a series of electrodes with aseptic processing and filling, with voltage gradients of the order of 10 V/cm (much less than the thousands of V/cm found in pulsed electric field applications) and was developed to enable processing of high-solids fraction foods with solids of up to 25 mm in size, at flows of up to 3,000 kg/h. Described by Parrott (1992), the heater consisted of a vertical or near-vertical tube up to 10 m in length and 75 mm in diameter, containing a series of up to seven electrode housings, each containing a single cantilever electrode across the tube. Current density is much higher in the connecting tubes than in the electrode housings, so the majority of the heating occurs in the tube. Other manufacturers include Emmepiemme SRL (Italy), who has installed more than 20 plants (manufacturer ’s information, 2007). Commercial plants for the processing of sauces, fruits, and tomatoes have been sold, although the process is not in widespread use. The original concept was to use ohmic processes to give HTST sterilization processes to solid–liquid mixtures, although the method has been used for pasteurization (Tucker et al. 2002) and proposed for blanching (Icier et al. 2006).
• Microwave processing, in which heat is generated by molecular vibrations (Knoerzer et al. 2006, 2009, and also Chapters 6 and 7). • Radio frequency heating, where heat is generated by dielectric heating, where the energy is transferred directly to the product, targeting it and not the surrounding air (Orsat and Raghavan 2005). • High-pressure thermal sterilization, in which heat is generated volumetrically by the increase in pressure up to 700 MPa—if heat losses through the vessel walls can be prevented, it is possible to reach uniform sterilization temperatures (Knoerzer et al. 2007, and Chapter 5). All of these technologies can be limited in practice by nonhomogeneities of the fields, which result in heat generation (e.g., the field patterns shown in work such as Ayappa et al. 1992; van Remmen et al. 1997; Zhang and Fryer 1993a). Without effective understanding and mathematical models, it is difficult to design and scale up the processes other than empirically. Any inhomogeneities in the delivery of the field generate nonuniform heating, affecting the rate and the distribution of microbial destruction. As with conventional thermal processing, it becomes necessary to control any process to process the most difficult part to reach, which may well lead to quality loss for the rest of the material. Some of the inhomogeneities that arise are unavoidable, as the food itself is not uniform. Nonuniformities on the cellular scale of plant or animal tissue are probably inevitable, but at a larger scale, problems may arise due to heterogeneous food composition. The process designer must also consider the possibility of introducing nonuniformity into the process as a result of incorrect design, either of the process equipment or of the formulation of the product. In slow processes, it will be possible for the temperature differences that result from these changes to equalize themselves out as a result of thermal conduction. The larger the distance between highand low-temperature regions, the longer this process will take, resulting in more restrictions on the
Chapter 8
process. Ideally, the process should offer HTST quality on particulate foods. A number of authors have addressed the issue of modeling ohmic heating of foods, first in attempts to understand the process (de Alwis et al. 1989) and then to try to develop efficient models that can be used in process and product design. This chapter reviews the types of modeling and experimental approach that have been carried out, with the aim of explaining the key design factors that would have to be taken into account in order to model the process. The approach taken is somewhat historical, reflecting the way the models were developed.
8.2. Electrical Heating of Foods: Governing Processes 8.2.1. Electrical Heating The familiar Ohm’s law describes the relationship between voltage V, current I, and resistance R in a system: V = IR
(8.1)
which leads to the equation that describes the power generation: P = I2R = V2 R
(8.2)
where P is in Watts. This is not the most convenient way of representing heat generation; it is best to consider the field gradient that results from the distribution of materials of various electrical conductivities. The voltage distribution is given by Laplace’s equation: ∇ ⋅ (κ ⋅∇V ) = 0
(8.3)
where κ is the electrical conductivity, and then the rate of heat generation is given by Q = κ E2
(8.4)
where E =∇V
(8.5) 3
Q is a volumetric heating rate (W/m ) that can be related to temperature increase in the absence of heat losses through the volumetric heat capacity (ρCp) as
Multiphysics Modeling of Ohmic Heating
ΔT =
κ E2 ρC p
157
(8.6)
In a solid, the evolution of temperature T, as a function of time t, will be a function of conventional thermal conduction within a material as well as heat generation and is governed by:
∂ (8.7) ( ρC pT ) = ∇ (λ ⋅∇T ) + Q ∂t throughout the system with appropriate boundary conditions. The problem is complicated even in the absence of fluid flow and thermal convection by the dependence of electrical conductivity on temperature, so that the voltage and thermal fields are coupled. Solution of industrially relevant problems can be computationally expensive, so most early studies simulated simplified two-dimensional (2D) cases.
8.2.2. Combination with Flow Equations Even in a notionally static system of solids in a liquid, fluid flow will occur through convection. In industrial systems where fluid flow cannot be neglected (e.g., APV heater) and where fluid is pumped past a series of electrodes, forced convection also occurs. The number and complexity of the equations to be solved consequently increases, as does computational difficulty. The form of the equations is the same as in other volumetric heating processes such as high-pressure sterilization (Knoerzer et al. 2007, and Chapter 5). For the flows in the system, the Navier–Stokes equation must be solved: ⎤ ⎡ ∂v ρ ⎢ + v ⋅∇v ⎥ = −∇P + ∇ ⋅ ( μ ⋅ v ) + ρ g (8.8) ⎦ ⎣ ∂t where v is the velocity vector and μ the viscosity. The corresponding thermal field, assuming nonisothermal flow, is then
∂ ( ρC p T ) + v ⋅∇ ( ρC p T ) = Q + ∇ ⋅ (λ∇T ) (8.9) ∂t where the source term Q is calculated from Equations 8.3 and 8.4. Complete solution of flow, thermal, and electric fields thus requires solution of Equations
158
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
8.3, 8.4, 8.8 and 8.9, which are strongly coupled through the temperature dependence of electrical conductivity, viscosity, and other physical properties. These dependencies can be complex and nonlinear, such as the rapid changes of electrical conductivity when cells lyse (see below, and Halden et al. 1990). These equations need to be solved with appropriate initial and boundary conditions: • For the electric field, either insulation or a constant voltage across the boundaries of the system; voltage is applied at t = 0. • For temperature, usually insulated boundaries; a uniform initial temperature across the system is also commonly assumed. • For velocity, few models have attempted anything like a realistic case; models have assumed either no motion or constant-phase velocity with slip between particle and liquid; interfacial heat transfer is then controlled by a heat transfer coefficient. The difficulty of solving this set of equations means that very few workers have attempted their solution in anything like a realistic situation. Many of the simulations have concentrated on the identification of conditions for worst or best case or design rules, which can be used for ohmic formulations.
8.2.3. Validation of Basic Approach 8.2.3.1. Electrical Conductivity The first studies of ohmic heating were carried out to confirm that the heat generation was purely resistive and to identify how different parameters can be measured. Clearly, electrical conductivity is a key component of the understanding needed to generate efficient models to predict heating rates. However, it is important to note that electrical conductivity is frequency dependent; a number of mistakes were made in the development of formulations when data measured using conventional conductivity meters (which work at very high frequency) was used to build formulations for the APV ohmic heater (which used U.K. mains frequency of 50 Hz). Commonly, this gives errors in the region of 10% (Mitchell and de Alwis 1989).
The electrical conductivity for some materials can, to a first approximation, be taken to be a linear function of temperature over the range considered in the heating process: that is, κ = κ0 + kT, where κ0 and k depend on the properties of the material. This approximation can be adopted for most simple water-based materials (i.e., brine, food gels, agar, egg albumen). In general, however, the temperature– conductivity relationship for food solids or complex liquids—such as starch solutions—will be nonlinear. This in part arises because of the structure of foods: for example, when starch gelatinizes at 70°C. A survey of different materials and the ways in which electrical conductivity can change with temperature are given in Halden et al. (1990); subsequent work has given more detail (such as Palaniappan and Sastry 1991; Wang and Sastry 1993). Changes can occur due to processes such as • Phase change, such as melting of fats or gelatinization of starch-based fluids such as sauces. • Breakdown of cells; for example, when cells lyse at ca. 70–80°C, they release their contents and increase the conductivity. • Expression of air: Foods such as mushrooms need pre-treatment to remove air before they can heat at any significant rate. A large number of studies have since been done on determining the conductivity of various materials. Pre-treatments such as blanching and salt infusion soaking treatments were proposed in order to match the electrical conductivities of the liquid and solid phases (Palaniappan and Sastry 1991; Wang and Sastry 1993). The conductivity of mixtures has been shown to vary with factors such as particle size (Zareifard et al. 2003), fat content (Sarang et al. 2008; Zell et al. 2009), and structure (Wang et al. 2001). At the low frequencies used, electrolysis can sometimes be a problem; the original APV system used platinized titanium to avoid electrolysis, but this has not always been done in subsequent studies. Electrolytic reactions will absorb some of the electrical energy dissipated in the system, and can often be detected by anomalously high “specific heat capacities” of the food—power is going in but the temperature is not changing.
Chapter 8
1. Using a potential model to predict a simple distribution of the field: For some limited cases of high symmetry, the system is analytic and the heat generation in the solid and liquid can be calculated. For example, if a cylinder or sphere of solid of conductivity κs is placed in a liquid of conductivity κl, the field distribution that results is then analytic, and the ratio of the heating rates for the two can be found. For spheres, the ratio of heating rates between the liquid at infinity and the solid is RTs =
( ρC p )l (κ s + 2κ l ) ( ρC p )s 9κ sκ l
2
=
( ρC p )l ( Rκ + 2 ) ( ρC p )s 9 Rκ
2
(8.10) and then for cylinders RTc =
( ρC p )l (κ c + κ l ) ( ρC p )s 4κ cκ l
2
=
( ρC p )l ( Rκ + 1) ( ρC p )s 4 Rκ
2
(8.11) This type of analysis identifies cases where solids overheat liquids; if the thermal capacities are equal, solids will heat faster for 1 < Rκ < 4, while the maximum for the cylinder is the same heating rate at Rκ = 1. Figure 8.2 shows experimental validation from de Alwis et al. (1989); the data suggests that the same shape of curves are seen, and thus the process is truly ohmic.
159
1.5
1.0 RT
8.2.3.2. Simple Models Preliminary work used a simple batch cell (de Alwis et al. 1989) that allowed measurements at the frequencies and field strengths that are representative of the real system. This approach has been widely followed (such as by Ye et al. 2003b; Marra et al. 2009); the ohmic process works at voltage gradients that are low enough that they can readily be generated under lab conditions. The cell developed by de Alwis et al. (1989) has an open surface, and is thus prone to evaporative losses, which affect temperature; most subsequent cells have been closed and sometimes pressurized to eliminate boiling. Two sets of preliminary work were carried out by de Alwis et al. (1989) using very simplistic models that generated the confidence to build more complete ones:
Multiphysics Modeling of Ohmic Heating
0.5
0.0 0.0
1.0
2.0
3.0
4.0
RK Figure 8.2. Variation of the differential heating rates between solid spheres and the fluid showing a plot of Equation 8.10 assuming equal volumetric heat capacities in both phases and experimental data for 4 cm dough spheres (de Alwis et al. 1989).
2. Using a circuit analogy: Single planar solids with conductivities higher and lower than the liquid were placed both parallel to the field and at right angles to it, and the field applied. Typical results for the less conductive solid are shown in Figure 8.3. When the particle is essentially in parallel to the field, the electric field will be diverted around it; as a result, it will underheat the liquid. In contrast, when it is placed in series with the fluid, all (or most) of the current has to flow through the more resistive component, which overheats as a result. That particles can overheat the fluid is significant—in conventional processing, obviously, the reverse is true. One key difference between thermal and electrical heating is the variation in the appropriate conductivity. While thermal conductivity can vary from ca. 0.1–1 W/mK for foods (and up to 400 W/mK for copper), electrical conductivity can vary many orders of magnitude, from very strong conductors (metals of the order 107 S/m) to almost total insulators (of the order of 10−10 S/m for glass). Both very high- and very low-conductivity inclusions, such as metal and plastic, will in practice have a negligible heating rate, in the first case because the
160
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
80
80
Temperature (°C)
(b) 100
Temperature (°C)
(a) 100
60 40 20 0
0
50
100 Time (s)
150
200
60 40 20 0
0
50
100 Time (s)
150
200
Figure 8.3. Plots of heating (heavy line: solid, thin line: liquid) of potato particles (3 × 4 × 0.75 cm) with the large phase (a) parallel and (b) perpendicular to the field (de Alwis et al. 1989).
conductivity is so low that heating is low (although the current flow may be high) and in the second case because no current flows through the solid. There is thus a problem with low-conductivity inclusions in foods (such as fats and bone in meat), which will both heat slowly themselves and distort the field so that regions around them also heat slowly. Conventional thermal processes are slow enough that these differences even out through conduction. In an incorrectly designed ohmic formulation, cold spots may occur, and there will be insufficient time for thermal equilibrium to be reached.
8.3. Modeling and Validation 8.3.1. Single-Phase Behavior Most studies of ohmic heating have considered multiphase flow, in which particles can be processed rapidly. Quarini (1995) considered the behavior of single-phase fluids undergoing electrical heating while flowing in a tube, and showed that the variation of velocity across the flow would itself lead to nonuniform temperature, with the hottest regions being at the walls—the APV heater employed wall cooling to minimize this effect. The effect of adding particles is to flatten the flow profile, as discussed below.
8.3.2. Simple 3D Models and Extension to Fluid Flow The sort of effects seen in Section 8.2 led to concerns that high- or low-conductivity inclusions might be possible inside the system, resulting in effects inside the system similar to or the same as those seen in Figure 8.3. Complex “shadow effects” are possible around solids (see, e.g., Fryer et al. 1993; Kemp et al. 1999). In low-viscosity fluids, it might be expected that the temperature differences will even out through mixing, but many food fluids are of high viscosity. De Alwis and Fryer (1992) developed a 2D finite element (FE) model to simulate the behavior of slices of solid immersed in a fluid; that is, the situation of Figure 8.3. Figure 8.4 shows similar 2D simulations, in which the cold regions can be seen. This type of model does not solve Equations 8.8 and 8.9; Equations 8.3 and 8.7 are solved for the field and temperature distributions. When there is little mixing, then the temperature differences between different regions of a food mixture will be more pronounced. A simplistic attempt to model fluid mixing was made by defining an enhanced thermal conductivity, λ* (Fryer et al. 1993), and it was shown that this approach could simulate the different mixing behaviors resulting
Chapter 8
Multiphysics Modeling of Ohmic Heating
161
(b)
(a)
Time = 150 Surface: Temperature (°C) Max: 83.066
Time = 150 Surface: Temperature (°C) Max: 117.341 0.08
115
0.06
110
0.04
105
0.08
0.04
75
0.02
0.02 100
0.00
95
–0.02
65
–0.02
90
–0.04
–0.06
85
–0.06
–0.08
80
–0.08
0
70
0.00
–0.04
–0.06 –0.04 –0.02
80
0.06
0.02 0.04 0.06 Min: 78.311
60 55
–0.06 –0.04 –0.02
0
0.02 0.04 0.06 Min: 52.8
Figure 8.4. Temperature contours for (a) solids having an electrical conductivity of 2 S/m immersed in a fluid of 1 S/m, and (b) solids of electrical conductivity 4 S/m immersed in a fluid with an electrical conductivity of 2 S/m. See color insert.
from changes in viscosity. Both the simulations and the experiments suggest that the coldest spot can arise within the particle (e.g., for a particle of low conductivity) or in the bulk of the fluid (e.g., around the sides of a particle of high conductivity). The problem of modeling the commercial APV heater is that it involves a flowing of solid–liquid mixture. It is not possible to model two-phase solid– liquid flows by full solution of the equation set described above, even without solving for the electric and thermal fields. To develop a model to approximate the behavior of the system, simplifications have to be made. Zhang and Fryer (1993b, 1994) assumed that the flow consisted of a series of spheres evenly distributed in a liquid, so that a 3D “unit cell” could be modeled as representative of the whole, as in Figure 8.5. The heating rates of the two phases (i.e., Qs and Ql) were solved using an FE model to identify the heating rates as a function of solids fraction ϕ and Rκ. Assuming that the two phases travel at constant speed and are of uniform temperature, two heat balances can be written: For the solid:
(a)
(b)
Figure 8.5. Unit cell model: (a) particles on a cubic grid; (b) section of the grid that has to be modeled (from Zhang and Fryer 1993b).
dTS dx
(8.12)
φ dT ⋅ ha(TS − Tl ) + QL = vL (ρC p )L L (1− φ ) dx
(8.13)
−ha(TS − TL ) + QS = vS (ρC p )S while for the liquid:
In this case, the two equations are coupled through the interfacial heat transfer term ha, the product of
162
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
the heat transfer coefficient, and the interfacial area per unit volume. The changes in the temperature will change the electrical conductivities of the two. The heat generation terms were solved numerically for the unit cell in 3D for a range of Rκ and ϕ, and the data correlated as RQS =
9 Rκ
( Rκ + 1)
2
[1 − f (φ, Rκ )] + f (φ, Rκ ) Rκ
L
d
D
l Solid Mixed Fluid
Rfp
(8.14)
since the heat generation rate will vary between the first term (Eq 8.10, for ϕ = 0) and the second (for ϕ = 1). This model could be used to predict approximate temperatures for the two phases. The 3D solution of the unit cell was computationally expensive (and used a 1 GB hard drive which in 1989 cost more than £20,000!), but the model could then be run relatively efficiency using Equation 8.14 as a function. Clearly, a number of the approximations are not correct; temperatures and velocities are not uniform, nor are the particles spheres. However, it does offer an estimate of the whole system behavior. Benabderrahmane and Pain (2000) developed this type of model further, introducing thermal gradients into the particles and simulating thermal behavior, again for plug flow of the system but with slip between particles and liquids. Studies of how particle–liquid mixtures behave are discussed below.
8.3.3. Identification of Local Worst Case: Recent 3D Models Sastry (1992) and Sastry and Palaniappan (1992) have used an alternative approach to that shown above in which they approximate the 3D system using a circuit analogy and a network of resistors. This approach is probably less accurate than the Zhang and Fryer (1994) approach, as it does not solve for the field distribution, but is much less computationally expensive. The model assumes that the field lines are parallel so that the approximation shown in Figure 8.6 can be made. The problem that has been most studied is that of identification of the worst case, that is the coldest
Rfs1
Rfs2 Rfp
Figure 8.6. Circuit analogy (from Sastry and Salengke 1998). The model simplifies the system into parallel and series resistive elements.
spot in the process, against which the process must be designed. In conduction cooking, this is easy to identify, while for ohmic heating (as for other volumetric heating processes; see Chapters 4–7), it is difficult. Identification of the local worst case is obviously important as it allows the process designer to make changes to the formulation or process. A number of the commercial successes for ohmic heating have been in the processing of very uniform mixtures, such as fruit pieces in syrup, whose conductivity can be controlled and made uniform. Salengke and Sastry (2007) carried out a lengthy series of 3D simulations, both for the FE simulation of particles and the circuit model, and report computational times of several hundred seconds on a CRAY supercomputer, demonstrating the complexity of the equations and their coupling, even for relatively simple systems (linear change in conductivity with temperature was assumed). The simulations of Salengke and Sastry (2007) show, as would be expected, differences between the two models and a range of places in which the coldest spot can arise. In a flow situation, stirring of the fluid will occur, but, as shown by Kemp et al. (1999), particles in the low-field region will underheat even if they are capable of overheating the
Chapter 8
(a)
Multiphysics Modeling of Ohmic Heating
163
(b)
Time = 150 Slice: Temperature (°C)
Max: 95.833
Time = 150 Slice: Temperature (°C)
94
100
92
98
90
96
88
94
0 z
y
0
–0.05
0
86
x
92 z0
y Min: 84.54
Max: 102.253 102
x
–0.05
90 Min: 89.706 Figure 8.7. Three-dimensional solution of the Laplace equation for a fluid with electrical conductivity of 2 S/m and cubes with an edge of 1 cm having electrical conductivities of (a) 1 S/m and (b) 4 S/m. See color insert.
fluid. Further simulations are presented by Marra et al. (2009) based on a solution of the Laplace equation for the field distribution. A 3D solution of the Laplace equation is shown for solid cube particles in a fluid having an electrical conductivity of 2 and 4 S/m are shown in Figure 8.7a and b, respectively. The shadow regions of low temperature around the particle and the temperature differences between the fluid and particles for different conductivity ratios can be seen. A number of the predictions of the models have been validated using thermocouples; however, these are clearly invasive and will cause distortion of the electric field. Elegant visualization of the temperature field around particles was carried out by Ruan et al. (1999) and by Ye et al. (2003a, 2003b), in which magnetic resonance imaging (MRI) methods were used to study the temperatures in particle– liquid mixtures and gels. The method was used both to identify temperatures and to estimate particle– fluid heat transfer coefficients, which are important parameters in developing better models.
8.3.4. Validation of Ohmic Heating, and Measurements of Particle–Fluid Flows The commercial ohmic heating units and models described above involve flow of high-solids fraction mixtures, in which the carrier fluid is often viscous and non-Newtonian, through complicated 3D geometries. The food industry does not believe in models: The need is to validate them. Validating the desktop cell experiments is simple because thermocouples can be used, so long as they are insulated from the electric field. MRI experiments have also shown the effects that can arise. Full-scale monitoring of the commercial system requires measurement of the two-phase temperatures that cannot be done using static thermocouples. Indirect methods can show that particles overheat the fluid, for example, the liquid temperature in the holding tube can increase from inlet to outlet, as a result of heat transfer from the solids to the liquid (Kim et al. 1996a). Measurements to validate the flow field in an ohmic system require measurements of the distribution of
164
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
times that the two phases spend in the process. This can be done by some means of tagging particles and then measuring the time between entrance and exit. Palaniappan and Sizer (1997) suggest that measurements of 299 particle times is necessary for 99% confidence that the true behavior is being measured— this is a stringent requirement that many measurements have not met. The APV Baker equipment was validated as described by Kim et al. (1996a, 1996b) using particles containing spores of Bacillus stearothermophilus and chemical markers processed in a starch solution with 30–40% solids content. In some cases, higher lethality was observed at the center of the meatballs rather than near the surface, that is, confirming the predictions that particles may overheat the liquid as shown above. The authors considered that a laminar assumption (i.e., that some particles could travel twice as fast as the mean) was a suitable conservative one. More recently, Tucker et al. (2002) described the use of amylase-containing time–temperature indicators (TTIs) to validate an APV ohmic heater being used to pasteurize fruit pieces. Such methods, using microbial or chemical tracers, enable the whole effect of the process to be determined. To determine how particles behave or to model the process, it is, however, necessary to determine particle trajectories in solid–liquid mixtures, but these are difficult to measure. Some data can be obtained optically (such as Lareo et al. 1997a, 1997b), but most real fluids are opaque. Particle flows control both the residence time in the system and the particle–fluid heat transfer coefficient, and are of importance in all of the heating, holding, and cooling sections of a process. A variety of methods have been used to study particle times-of-flight—that is, the time that particles spend in a system. Liu et al. (1993) described a system based on metal detectors to study particle flows, while Tucker and Heydon (1998) described Hall effect-based sensors that can be used—these formed the basis of some of the measurements made by Kim et al. (1996a, 1996b). Marcotte et al. (2000) reported experiments on an ohmic system using an ultrasonic method as well as a colored tracer. Hall effect sensors were also used by Eliot-Godereaux et al. (2001) to find the passage time distribution of
particles in a 10 kW APV ohmic heating system; particles travelled at less than the mean velocity throughout. Recently, Sarang et al. (2009) and Tulsiyan et al. (2009) discussed the measurement of residence time distribution (RTD) using radiofrequency identification (RFID)-tagged particles, and measure flows in the ohmic heater at Ohio State University, which uses stirred vessels between sets of electrodes. Chicken particles were tagged and passed through the process, and more than 299 readings were taken. The results show that the residence time distribution was wide, with some particles passing through significantly faster than the mean residence time (52 s as opposed to 92 s), and some travelling significantly slower. Chen et al. (2010) reported measurements made on a 2,000 L/h ohmic heater made by Rossi and Catelli in Italy, in which experimental temperatures are compared with a model built using the approach of Figure 8.6; agreement is excellent in all cases. The effect of varying various process parameters was also studied and the variation of both exit temperature and output lethality mapped; as expected, fluid and particle electrical conductivity have the greatest effect. Full knowledge of the flow field would be useful to enable the heating patterns of the solids and interphase heat transfer coefficient to be identified. Particle paths are, however, more difficult to identify than residence times, as information on the Lagrangian trajectory would be needed. Fairhurst et al. (2001) and Cox et al. (2003) use positron emission particle tracking (PEPT) to measure the velocity profile and trajectories both of large particles and of small tracers, which are isokinetic with the flow. PEPT enables observation of particle trajectories even through metal pipework. The results of Fairhurst et al. (2001) show that there are cases where particle velocities faster than twice the mean can be found under conditions where plugs of particles pass through the flow rapidly. Such conditions must be avoided in commercial practice. Combination of PEPT and TTIs has been demonstrated by Mehauden et al. (2009), who used PEPT to follow TTIs within a commercial mixer vessel. This type of approach might be valuable for identifying real flow patterns in commercial systems.
Chapter 8
8.4. Further Development of Ohmic Heating and Appropriate Modeling Computational power increases with Moore’s law; what once could be done only on a workstation can now be done on PCs or laptops. Simultaneous simulation of the thermal, electric, and flow fields in the ohmic system remains very difficult, however, but simulations of the single-particle situation are now feasible using relatively inexpensive equipment and codes such as COMSOL Multiphysics™ (COMSOL AB, Stockholm, Sweden). However, some recent developments do suggest how ohmic heating might find use in the industry. The most recent works of Sarang et al. (2009) and of Tulsiyan et al. (2009) have studied chicken chow mein formulations, suggesting that production of ready-to-eat meals is possible. One possible, if exotic, route is suggested by Jun and Sastry (2007), who discuss the use of the process in future space flight for reheating reusable pouches of food and give a computational fluid dynamics (CFD) model for heating and field behavior. The work of Chen et al. (2010) on the sterilization of solid–liquid mixes, from Campbells in the United States, shows that the original design intention may still prove profitable. A novel alternative ohmic process for the processing of single-phase viscous liquids has also been developed and modeled by Ghnimi et al. (2008, 2009). This minimizes any possible problems due to fouling and velocity profile by heating a jet of fluid flowing between two electrodes, as shown in Figure 8.8. Heating will occur only within the jet as the field is concentrated into it. Assuming a uniform radial velocity profile (as there is no shear across the fluid arising from a wall) for a jet of initial velocity u0 and radius R, the authors derive a model first for the velocity and radius of the jet with distance x from the nozzle using Bernoulli’s equation 1/ 2
u( x ) ⎛ 2 g ⎞ r ( x ) ⎛ 2 g ⎞ = ⎜ 1 + 2 x⎟ ; = ⎜ 1 + 2 x⎟ ⎝ ⎝ u0 u0 ⎠ R u0 ⎠
−1 / 4
(8.15)
and then obtain a model for the temperature rise under conditions where the electrical conductivity is linear with temperature by integrating the heat balance along the jet
Multiphysics Modeling of Ohmic Heating
165
Inlet mass flow 5 2 9 1
6 I
4
8
7
v
3
Outlet mass flow Figure 8.8. Liquid jet ohmic heater, showing as follows: 1: fluid jet falling between electrodes; 2: stainless steel electrode connected to the phase; 3: stainless steel electrode connected to the mass; 4: electrical isolation using PEEK bars with nuts and bolts; 5: radar sensor; 6: high-frequency electromagnetic wave generated by the radar sensor; 7: glass tube between electrodes; 8: injection of the nitrogen; 9: electrical insulation; I: alternate current in the jet; V: voltage applied at the boundaries of the electrodes (from Ghnimi et al. 2008).
p dT = κ 0 (1 + kt )E 2 ⋅ π [r ( x )]2 dx mC
(8.16)
This model is shown to agree well with the experimental results. The potential for this type of process is that it may overcome some of the problems associated with velocity and thermal profiles across pipework. Electric field processing may, however, also be useful in extraction and infusion. That electrical processing can enhance mass transport between solids and liquids was identified by Halden et al. (1990) in experiments on beetroot, in which the purple betanin dye moved much more quickly into the solution under ohmic treatment than under conventional processes. Schreier et al. (1993) quantified this effect by measuring the mass flux of betanin dye between a solid foodstuff (beetroot) and surrounding liquid under conventional and electrical heating at 100°C. Mass transfer of the dye under the influence of a 50 Hz applied electric field increased linearly with
166
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
increasing electric field. This work was repeated (Lima et al. 2001) at uniform temperatures below 100°C, and enhancement was found at 42 and 58°C but not at 72°C. This result was interpreted in terms of differing electrical conductivities due to the different processing methods. Kulshrestha and Sastry (2003) again studied beetroot and found that increasing the field strength increased the efflux of dye. It was proposed that the effect was due to electroporation of the material. Kemp and Fryer (2007) demonstrated that diffusion into solids could also be enhanced using electric fields. Alternating electric fields have been claimed to enhance a number of processes. Sastry and Salengke (1998) outlined a number of potential applications for alternating electric fields, described as “moderate electric field” processing by Sensoy and Sastry (2004). Juice yields of ohmically pre-treated samples were enhanced against conventional treatments, and the drying rates of fruit and vegetable tissue samples were enhanced against either conventional (steam) or microwave heating. Lima and Sastry (1999) studied the effect of electrical treatment on juice yield and suggested that electrical pre-treatment was useful. Zhong and Lima (2003) showed that drying of sweet potato was enhanced by ohmic pre-treatment, and extraction of rice bran oil is also increased (Lakkakula et al. 2004). If the treated material has a higher permeability, then it may be possible to increase extraction rates (Kulshrestha and Sastry 2003, 2010). In terms of modeling of the process, it is now easily possible to simulate complex particle–liquid heating patterns; however, the problem of solving for the flow patterns at the same time is much more complex. Efficient models for two-phase solid– liquid flows are not available as yet; some progress has been made in using discrete element methods in gas–solid flows and in combining CFD and discrete element method (DEM) models (such as Curtis and van Wachem 2004; Tsuji et al. 2008; Guo et al. 2010), and good data for processes such as heat transfer have been developed (Garic´-Grulovic´ et al. 2009). This type of modeling offers hope that the computational and theoretical complexity of modeling solid–liquid behavior can be addressed over the next decade.
8.5. Conclusions Ohmic heating is a method for food processing in which electric current is passed through the food and the material then heats as a result of its inherent electrical resistance. It is possible to see fluids and particles be heated at comparable rates. Preliminary experiments showed that heating is purely resistive, so that the heat generation distribution in the system can be modeled if the distribution of electrical conductivity is known. However, to simulate fluid flow as well as heating involves simultaneous solution of models for the flow, thermal, and electrical fields, with the three being strongly coupled through the temperature dependence of electrical conductivity and viscosity. A series of models have been built for the process that demonstrates various factors that have been shown in practice, such as particle overheating. The difficulty in the process arises when the fluids (or sections of them) have electrical conductivities significantly different from one another: Under those conditions, the models show that local “shadow regions” of low electric field strength can arise, resulting in large differences in temperature between the liquid and the solid. Within the liquid, these changes in temperature can be minimized by improving convective mixing, an effect that is more pronounced for low-viscosity fluids such as water. However, commercial food processes commonly use high-viscosity carrier fluids (such as starch) in which convective processes will be significantly slower. Three-dimensional simulations of the heating patterns that occur have been developed, but only very simple models for the flows—in which phase volumes are constant—have been attempted. The original vision for the APV Baker process to rapidly sterilize heterogeneous mixtures such as ready-to-eat meal formulations has not been realized by ohmic heating; most commercial products processed using this system are homogeneous. However, there are now a number of manufacturers selling ohmic equipment successfully. Alternative uses such as the use of electric fields to enhance mass transfer may also be reaching commercial activity.
Chapter 8
Full simulation of the flows and heating rates found in two-phase systems will require developments both in computational size and in solid–liquid flow modeling.
Notation Cp E g ha I k P P p Q Ql Qs R R RQs RTc RTs Rκ T t Tl Ts u0 V v vl vs κ κ0 κc κl κs λ λ* μ
Heat capacity Electrical field strength Gravity Interfacial heat transfer Current Temperature coefficient Power Pressure Pressure Volumetric heating rate Heating rate for liquid Heating rate for solid Resistance Radius Ratio of heat generation Ratio of heating rates for cylinder Ratio of heating rates for sphere Ratio of electrical conductivities Temperature Time Temperature liquid Temperature solid Initial velocity Voltage Velocity vector Velocity vector for liquid Velocity vector for solid Electrical conductivity Electrical conductivity at reference temperature Electrical conductivity of solid (cylinder) Electrical conductivity of liquid Electrical conductivity of solid (sphere) Thermal conductivity Enhanced thermal conductivity Viscosity
J/kgK V/m m/s2 A W Pa Pa W/m3 W/m3 W/m3 Ω m
K s K K m/s V
S/m S/m S/m S/m S/m W/mK W/mK Pa/s
ρ ϕ x m D L d RfP RfS1 RfS2
Multiphysics Modeling of Ohmic Heating
Density Solids fraction Distance from the nozzle Mass flow rate Diameter Length Diameter of solid Parallel resistive element Series resistive element 1 Series resistive element 2
167
kg/m3 m kg/s m m m Ω Ω Ω
References de Alwis AAP, Fryer PJ. 1990a. The use of direct resistance heating techniques in the food industry. J Food Eng 11:3–27. de Alwis AAP, Fryer PJ. 1990b. A finite element analysis of heat generation and transfer during ohmic heating of food. Chem Eng Sci 45:1547–1560. de Alwis AAP, Fryer PJ. 1992. Operability of the ohmic heating process: Electrical-conductivity effects. J Food Eng 15(1): 21–48. de Alwis AAP, Halden K, Fryer PJ. 1989. Shape and conductivity effects in the ohmic heating of foods. Chem Eng Res Design 67:159–168. Ayappa KG, Davis HT, Davis EA, Gordon J. 1992. Twodimensional finite element analysis of microwave heating. AIChE J 38:1577–1592. Benabderrahmane Y, Pain JP. 2000. Thermal behavior of a solid– liquid mixture in an ohmic heating sterilizer—Slip phase model. Chem Eng Sci 55:1371–1384. Chen C, Abdelrahim K, Beckerich I. 2010. Sensitivity analysis of continuous ohmic heating process for multiphase foods. J Food Eng 98:257–265. Cox PW, Bakalis S, Ismail H, Forster R, Parker DJ, Fryer PJ. 2003. Visualisation of three-dimensional flows in rotating cans using positron emission particle tracking (PEPT). J Food Eng 60(3):229–240. Curtis JS, van Wachem B. 2004. Modeling particle-laden flows: A research outlook. AIChE J 50:2638–2645. Eliot-Godereaux SC, Fairhurst PG, Goullieux A, Pain JP. 2001. Passage time distributions of cubes and spherical particles in an ohmic heating pilot plant. J Food Eng 47:11–22. Fairhurst PG, Barigou M, Fryer PJ, Pain JP, Parker DJ. 2001. Using positron emission particle tracking (PEPT) to study nearly neutrally buoyant particles in high solid fraction pipe flow. Int J Multiphase Flow 27(11):1881–1901. Fryer PJ, de Alwis AAP, Koury E, Stapley AGF, Zhang L. 1993. Ohmic heating of solid-liquid foods: Heat generation and convection effects. J Food Eng 18:101–125. Garic´-Grulovic´ RV, Grbavcˇic´ ZB, Boškovic´-Vragolovic´ N, Zorana LJ, Arsenijevic´ ZL. 2009. Mass transfer in vertical liquid– solids flow of coarse particles. Powder Technol 189:130–136.
168
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Ghnimi S, Flach-Malaspina N, Dresch M, Delaplace G, Maingonnat JF. 2008. Design and performance evaluation of an ohmic heating unit for thermal processing of highly viscous liquids. Chem Eng Res Design 86:626–632. Ghnimi S, Zaid I, Maingonnat JF, Delaplace G. 2009. Axial temperature profile of ohmically heated fluid jet: Analytical model and experimental validation. Chem Eng Sci 64:3188–3196. Guo Y, Wu CY, Kafui KD, Thornton C. 2010. Numerical analysis of density-induced segregation during die filling. Powder Technol 197:111–119. Halden K, de Alwis AAP, Fryer PJ. 1990. Changes in the electrical conductivity of foods during ohmic heating. Int J Food Sci Technol 25:9–25. Icier F, Hasan Yildiz H, Baysal T. 2006. Peroxidase inactivation and colour changes during ohmic blanching of pea puree. J Food Eng 74:424–429. Jun S, Sastry S. 2007. Reusable pouch development for long term space missions: A 3D ohmic model for verification of sterilization efficacy. J Food Eng 80:1199–1205. Kemp MR, Fryer PJ. 2007. Enhancement of diffusion through foods using alternating electric fields. Innov Food Sci Emerg Technol 8:143–153. Kemp MR, Davies L, Fryer PJ. 1999. The geometry of shadows: Effects of inhomogeneities in electrical field processing. J Food Eng 40:245–258. Kim HJ, Choi YM, Yang APP, Yang TCS, Taub IA, Giles J, Ditusa C, Chall S, Zoltai P. 1996a. Microbiological and chemical investigation of ohmic heating of particulate foods using a 5 kW ohmic system. J Food Proc Preserv 20:1. Kim HJ, Choi YM, Yang TCS, Taub IA, Tempest P, Skudder P, Tucker G, Parrott DL. 1996b. Validation of ohmic heating for quality enhancement of food products. Food Technol 50(5):253–255, 257–261. Knoerzer K, Regier M, Schubert H. 2006. Microwave heating: A new approach of simulation and validation. Chem Eng Technol 29:796–801. Knoerzer K, Juliano P, Gladman S, Versteeg C, Fryer PJ. 2007. A computational model for temperature and sterility distributions in a pilot-scale high-pressure high-temperature process. AIChE J 53:2996–3010. Knoerzer K, Regier M, Hardy EH, Schuchmann HP, Schubert H. 2009. Simultaneous microwave heating and three-dimensional MRI temperature mapping. Innov Food Sci Emerg Technol 10:537–544. Kulshrestha SA, Sastry SK. 2003. Frequency and voltage effects on enhanced diffusion during moderate electric field (MEF) treatment. Innov Food Sci Emerg Technol 4: 189–194. Kulshrestha SA, Sastry SK. 2010. Changes in permeability of moderate electric field (MEF) treated vegetable tissue over time. Innov Food Sci Emerg Technol 11(1):78–83. Lakkakula NR, Lima M, Walker T. 2004. Rice bran stabilization and rice bran oil extraction using ohmic heating. Bioresour Technol 92:157–161.
Lareo C, Branch CA, Fryer PJ. 1997a. Particle velocity profiles for solid-liquid food flows in vertical pipes part I. Single particles. Powder Technol 93(1):23–34. Lareo C, Nedderman RM, Fryer PJ. 1997b. Particle velocity profiles for solid-liquid food flows in vertical pipes part II. Multiple particles. Powder Technol 93(1):35–45. Lima M, Sastry S. 1999. The effects of ohmic heating frequency on hot-air drying rate and juice yield. J Food Eng 41:115–119. Lima M, Heskitt BF, Sastry SK. 2001. Diffusion of beet dye during electrical and conventional heating at steady-state temperature. J Food Process Eng 24(5):331–340. Liu S, Pain JP, Proctor J, de Alwis AAP, Fryer PJ. 1993. An experimental study on particle flow velocities in solid-liquid food mixtures. Chem Eng Commun 124:97–114. Marcotte M, Trigui M, Tatibouët J, Ramaswamy HS. 2000. An ultrasonic method for assessing the residence time distribution of particulate foods during ohmic heating. J Food Sci 65: 1180–1186. Marra F, Zell M, Lyng JG, Morgan DJ, Cronin DA. 2009. Analysis of heat transfer during ohmic processing of a solid food. J Food Eng 91:56–63. Mehauden K, Cox PW, Bakalis S, Fryer PJ, Fan X, Parker DJ, Simmons MJH. 2009. The flow of liquid foods in an agitated vessel using PEPT: Implications for the use of TTI to assess thermal treatment. Innov Food Sci Emerg Technol 10(4): 643–654. Mitchell FRG, de Alwis AAP. 1989. Electrical conductivity meter for food samples. J Phys E 22:554–556. Orsat V, Raghavan GSV. 2005. Radio-frequency processing. In: DW Sun, ed., Emerging Technologies for Food Processing, 445–468. London: Academic Press/Elsevier. Palaniappan S, Sastry SK. 1991. Electrical conductivities of selected solid foods during ohmic heating. J Food Process Eng 14:221–236. Palaniappan S, Sizer CE. 1997. Aseptic process validation for food containing particulates. Food Technol 51(8):60–68. Parrott DL. 1992. Use of ohmic heating for aseptic processing of food particulates. Food Technol 46:68–72. Quarini GL. 1995. Thermalhydraulic aspects of the ohmic heating process. J Food Eng 24:561–574. van Remmen HHJ, Ponne CT, Nijhuis HH, Bartels PB, Kerkhof PJAM. 1997. Van microwave heating distributions in slabs spheres and cylinders with relation to food processing. J Food Sci 61:1105. Ruan R, Chen P, Chang K, Kim HJ, Taub IA. 1999. Rapid food particle temperature mapping during ohmic heating using FLASH MRI. J Food Sci 64:1024–1026. Salengke S, Sastry SK. 2007. Experimental investigation of ohmic heating of solid–liquid mixtures under worst case heating scenarios. J Food Eng 83(3):324–336. Sarang S, Sastry SK, Knipe L. 2008. Electrical conductivity of fruits and meats during ohmic heating. J Food Eng 87:351–356. Sarang S, Heskitt B, Tulsiyan P, Sastry SK. 2009. Residence time distribution (RTD) of particulate foods in a continuous flow pilot-scale ohmic heater. J Food Sci 74:E322–E327.
Chapter 8
Sastry SK. 1992. A model for heating of liquid-particle mixtures in a continuous flow ohmic heater. J Food Process Eng 15:263–278. Sastry SK, Palaniappan S. 1992. Mathematical modeling and experimental studies on ohmic heating of liquid-particle mixtures in a static heater. J Food Process Eng 15:241–261. Sastry SK, Salengke S. 1998. Ohmic heating of solid-liquid mixtures: A comparison of mathematical models under worst-case heating conditions. J Food Process Eng 21:441–458. Schreier PJR, Reid DG, Fryer PJ. 1993. Enhanced diffusion during the electrical heating of foods. Int J Food Sci Technol 28:249–260. Sensoy I, Sastry SK. 2004. Extraction using moderate electric fields. Food Eng Phys Prop 69(1):7–13. Tsuji T, Yabumoto K, Tanaka T. 2008. Spontaneous structures in three-dimensional bubbling gas-fluidized bed by parallel DEM–CFD coupling simulation. Powder Technol 184: 132–140. Tucker GS, Heydon C. 1998. Food particle residence time measurement for the design of commercial tubular heat exchangers suitable for processing suspensions of solids in liquids. Food Bioproducts Process 76:208–216. Tucker GS, Lambourne T, Adams JB, Lach A. 2002. Application of a biochemical time–temperature integrator to estimate pasteurisation values in continuous food processes. Innov Food Sci Emerg Technol 3:165–174. Tulsiyan P, Sarang S, Sastry SK. 2009. Measurement of residence time distribution of a multicomponent system inside an ohmic heater using radio frequency identification. J Food Eng 93:313–317.
Multiphysics Modeling of Ohmic Heating
169
Wang CS, Kuo SZ, Kuo-Huang LL, Wu JSB. 2001. Effect of tissue infrastructure on electric conductance of vegetable stems. J Food Sci 66:284–288. Wang WC, Sastry SK. 1993. Salt diffusion into vegetable tissue as a pretreatment for ohmic heating: Electrical conductivity profiles and vacuum infusion studies. J Food Eng 20:299–309. Ye X, Ruan R, Chen P, Chang K, Ning K, Taub I, Doona C. 2003a. Accurate and fast temperature mapping during ohmic heating using PRF shift MRI thermometry. J Food Eng 59:143–150. Ye X, Ruan R, Chen P, Doona C, Taub I. 2003b. MRI temperature mapping and determination of the liquid–particulate heat transfer coefficient in an ohmically heated food system. J Food Sci 68:1341–1346. Zareifard MR, Ramaswamy HS, Trigui M, Marcotte M. 2003. Ohmic heating behavior and electrical conductivity of twophase food systems. Innov Food Sci Emerg Technol 4:45–55. Zell M, Lyng JG, Cronin DA, Morgan DJ. 2009. Ohmic heating of meats: Electrical conductivities of whole meats and processed meat ingredients. Meat Sci 83:563–570. Zhang L, Fryer PJ. 1993a. Electrical resistance heating of foods. Trends Food Sci Technol 4:364–369. Zhang L, Fryer PJ. 1993b. Models for the electrical heating of solid-liquid food mixtures. Chem Eng Sci 48:633–643. Zhang L, Fryer PJ. 1994. Food processing by electrical heating; the sensitivity of product sterility and quality to process parameters. AIChE J 40:888–898. Zhong T, Lima M. 2003. The effect of ohmic heating on vacuum drying rate of sweet potato tissue. Bioresour Technol 87(3):215–220.
Chapter 9 Basics for Modeling of Pulsed Electric Field Processing of Foods Nicolás Meneses, Henry Jaeger, and Dietrich Knorr
9.1. Introduction The combination of empirical models with numerical simulations has been already implemented and successfully used for the characterization of engineering processes. Based on the basic physical phenomena, such as the conservation of mass, momentum, and energy, several theoretical models have been developed, for example, the Navier– Stokes equations, and have been used to simulate complex systems and processes (Ferziger and Peric 2002). The joule heating, a theoretical model to describe the temperature changes as a function of the electric field strength in conductive media, has been used to simulate pulsed electric field (PEF) processes for food material, among other numerous applications. The resulting temperature increase in the media during PEF processing as a function of the electric field strength and the treatment time was also validated by experimental results showing good prediction accuracy (Fiala et al. 2001; Lindgren et al. 2002; Van den Bosch et al. 2003; Gerlach et al. 2008; Jaeger et al. 2009). Mechanistic models for describing the microbial inactivation phenomena, based on electroporation and electrical breakdown, have been developed
(Zimmermann et al. 1974, 1976; Zimmermann 1986; Tsong 1990), but not yet used for describing the microbial population after a PEF treatment (Lelieveld et al. 2007). On the other hand, only empirical models have been developed to describe the inactivation of microorganisms and enzymes, and the degradation of food compounds in dependency on the PEF process parameters. To date, the most frequently used parameters to describe the PEF processing of foods are the treatment time and the electric field strength. The electric field strength and the treatment time of any given PEF process can be predicted, and, therefore, the combination of empirical with theoretical models becomes important for this purpose. Using experimentally obtained models (i.e., microbial inactivation kinetics) and theoretical models (i.e., mass conservation, joule heating, charge conservation, and so on) and implementing both into a numerical simulation allows the study of the microbial inactivation process not only after the treatment, but also during PEF processing. These concepts can lead to an optimization of the PEF process and assist in the design of an appropriate treatment chamber, with a homogeneous electric field strength distribution, treatment time, temperature, and microbial inactivation.
Innovative Food Processing Technologies: Advances in Multiphysics Simulation, First Edition. Edited by Kai Knoerzer, Pablo Juliano, Peter Roupas, and Cornelis Versteeg. © 2011 by John Wiley & Sons, Ltd. and Institute of Food Technologists. Published by John Wiley & Sons, Ltd. ISBN: 978-0-813-81754-5
171
172
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
This chapter is focusing on four key aspects relevant to PEF modeling and its implementation into numerical simulations. The first part is related to the Multiphysics nature of PEF processing, which is described by governing equations such as fluid dynamics, heat transfer, and electrical phenomena. The second part focuses on mathematical equations to describe the PEF process as a continuous system for liquid food pasteurization. Included in the mathematical equations are process parameters such as energy input, pulse energy, pulse shape, and treatment time. An overview of the main treatment chamber designs used for PEF treatment of food together with their relevant electrical properties is also given. Physical properties such as rheological properties, thermal properties, and electrical properties will be discussed in the following section, which points out the interaction of the properties mentioned with fluid flow, heat transfer, and electrical treatment of foods. The last part is focusing on PEF application as pasteurization technology and describes the main kinetic models suitable for further simulation considering microbial and enzyme inactivation.
9.2. Governing Equations for Multiphysics Simulation of PEF Processing PEF processing is a Multiphysics phenomenon. The relevant variables are changing not only with time but also with space; hence, it is necessary to describe the phenomena by partial differential equations (Van Boekel 2009). The three main equations to describe a thermohydrodynamics model are the mass conservation, the conservation of momentum, and the energy conservation equations (Ferziger and Peric 2002; see also other chapters in this book, e.g., Chapters 4, 5, and 11).
∂ρ + ∇ ⋅ ( ρu ) = 0 ∂t
(9.1)
Conservation of momentum:
ρ
∂u T − ∇ ⋅ η ⋅ ∇u + (∇u ) + ρ (u ⋅∇ ) u + ∇p = F ∂t (9.2)
(
)
where ρ denotes the density of the fluid (kg/m3), u represents the average velocity (m/s), η is the dynamic viscosity (kg/m/s), p denotes the pressure (Pa), and F represents the volumetric force vector (m/kg2/s).
9.2.2. Heat Transfer Balance The general equations for an energy balance, which considers heat transfer through convection and conduction is:
ρc p
∂T + ∇ ( −λ ⋅∇T + ρc p Tu ) = Qs ∂t
(9.3)
where cp denotes the specific heat capacity (m2/s2/K), T is temperature (K), λ is the thermal conductivity (kg m/s3/K), ρ is the density (kg m−3), u is the velocity vector (m s−1), and Qs is a sink or source term (kg/m/s−3 or W/m3). If the velocity u is equal to zero, the general heat transfer equation turns into Equation 9.4, which governs pure conductive heat transfer in a solid or liquid:
ρc p
∂T + ∇ ( −λ ⋅∇T ) = Qs ∂t
(9.4)
In addition to the thermo-hydrodynamics equations, the Poisson’s equations are needed to extend the model to an electro-thermo-hydrodynamic problem, in order to consider the potential differential within the treatment chamber.
9.2.1. Conservation of Mass and Momentum
9.2.3. Poisson’s Equations
For incompressible Newtonian liquids, the mass and momentum conservation can be written in a spatiotemporal form as:
Assuming no generation of any electromagnetic forces, the relation between the electric potential and the electric field is given by:
Chapter 9
E = −∇ ⋅ V
Basics for Modeling of Pulsed Electric Field Processing of Foods
(9.5)
where E is the electric field strength (V/m). The equations to solve the electrical potential are based on charge conservation: −∇ ⋅ (σ∇V − J e ) = 0
(9.6)
where σ is the electrical conductivity (S/m), V is the electrical potential (V), and J e (A/m2) is the current density.
9.2.4. Coupling Heat Transfer and Poisson’s Equations During PEF processing, the temperature increases due to resistive (ohmic) heating from the electric current. The generated resistive heat Qs is proportional to the square of the magnitude of the electric current density J. Current density, in turn, is proportional to the electric field, which equals the negative of the gradient of the potential V: Qs ∝ J
2
(9.7)
The coefficient of proportionality is the electric resistance ρe = 1/σ, which is also the reciprocal of the temperature-dependent electrical conductivity σ = σ(T). Combining these facts gives the fully coupled relation: 1 2 2 Qs = J = σ E = σ ∇V σ
2
(9.8)
Thus, the conservation of charge, which describes the electric field strength behavior, can be coupled to the energy Equation 9.4 (Gerlach et al. 2008; see also Chapter 11 of this book). This set of coupled differential equations represents the electric-thermohydrodynamics model, suitable to simulate any continuous PEF processing as well as a batch process (when the velocity component is set to zero). These equations require the thermophysical properties of the food as input parameters. The quality of the process simulation depends on the accuracy of these models in describing the variables as a function of time, temperature, and electric field strength, as well as on given boundary conditions. Models of food properties as a function of temperature and time are
173
available in the literature, but data of food properties as a function of the electric field—in the range of microseconds—do not exist. Since the electric field is applied as pulses of the duration in the range of microseconds, and the time between the pulses is relatively long (milliseconds to seconds) in comparison to the duration of the pulse, any change in viscosity, density, heat capacity, and thermal conductivity of the food affected by the electric field can be neglected. This is not the case for the change of other food compounds or microorganisms during the electrical pulse, since certain structures are irreversibly affected. The effect of the electric field strength, treatment time (in the range of microseconds), and electrical energy on microorganisms has been reported since the early beginning of PEF research (Zimmermann et al. 1974). In order to consider the impact of process parameters, such as temperature, electric field strength, and treatment time on food compounds and/or microorganisms, the use of a new balance approach considering also diffusion of particles is needed. The general balance considering diffusion and reaction rate is: ∂ci + (u∇ ) ci = ∇ ( Di ∇ci ) + Qs ∂t
(9.9)
where ci (mol/m3) is the species or substance concentration, Di (mol/m3/s) denotes the diffusion coefficient, and Qs (W m3) represents a source or sink, typically due to chemical reactions; arbitrary kinetic expressions of the involved species (ci) can be introduced. When assuming ci being the concentration of any food compound and/or microorganism, and expressing it in terms of its relative activity RA, Equation 9.9 turns to: ∂RAi + (u∇ ) RAi = ∇ ( Di ∇RAi ) + Qs (9.10) ∂t In this case, Qs represents a source affecting the relative compounds activity as a function of process parameters, such as electric field strength, treatment time, residence time, and temperature, which can be determined experimentally. With this governing
174
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
equation, any food compound or microbial inactivation kinetic can be coupled with the electro-thermohydrodynamic model and thus can be simulated. Equations 9.1 to 9.10 are a set of coupled partial differential equations, which can be used to simulate any PEF process (batch and continuous processing), independent and dependent on temperature or time. The use of the correct kinetic inactivation model as dependent on PEF process parameters, or the adequate thermophysical property as dependent on temperature is discussed in the next sections.
9.3. PEF System and Modeling of PEF Processing Parameters A basic circuit for the generation of PEFs including the treatment chamber for their application to the food material is shown in Figure 9.1. The food in the treatment chamber can be modeled as a resistor Rc in parallel to a capacitor C. The resistance Rc is inversely proportional to the electrical conductivity of the food, whereas the capacitance C depends on the dielectric permittivity of the food. Both electrical characteristics can be affected by the geometry of the treatment chamber, but due to the short pulse durations, the capacitor properties can be neglected. The electrical conductivity of the media together with the electrical resistance as affected by the electrode configuration determines the total resistance of the treatment chamber (Loeffler 2006). The ratio between the total resistance of the treatment chamber and the rest of the electrical circuit determines the voltage drop and the resulting peak
voltage across the electrodes. The use of a treatment chamber with a high resistance results in a more effective voltage division and higher electric field strength in the treatment chamber. Furthermore, the microbial inactivation is generally enhanced when the medium has a high electric resistivity (Huelsheger et al. 1981; Mizuno and Hori 1988).
9.3.1. Pulse Shape and Pulse Width When the high-voltage switch (Figure 9.1) is set to position A (open), the capacitors will be charged. Then, as the switch is set to position B (closed), the capacitors will be discharged and a current will flow leading to the induction of an electric pulse in the treatment chamber. Two different pulse shapes are commonly used: square wave pulses and exponential decay pulses. Additionally, these pulses can be applied in a monoor bipolar manner (Beveridge et al. 2002). A square wave pulse can be mathematically represented as: V (t , τ ) = V0 ⋅ ( H1 − H 2 ) t<0 ⎧0 ⎪ H1 = ⎨1 2 t = 0 ⎪1 t>0 ⎩
t<0 ⎧0 ⎪ H 2 = ⎨1 2 t = τ ⎪1 t >τ ⎩
(9.12)
The pulse width of a square wave pulse is defined as the period of time in which the maximal voltage is maintained. Square wave pulses can be generated by using a switch with on–off function or an adequate network (Martín et al. 1994). In the case of exponential decay pulses, the voltage decay depends on the capacity of the capacitor(s) and the resistance, in accordance to the following equation (Ho and Mittal 2000): V (t ) = V0 ⋅ e
Figure 9.1. Electrical circuit for the generation of highvoltage pulses.
(9.11)
−
t R⋅C
(9.13)
where V(t) (V) is the voltage across the resistor at a given time t (s), V0 (V) is the initial voltage, R (Ω) is the resistance, and C (F) is the capacitance. The pulse width for exponential decay pulses is defined at the point where the voltage has decreased to 1/e ≈ 36.8% of its initial value, and it depends on
Chapter 9
Basics for Modeling of Pulsed Electric Field Processing of Foods
175
the resistance and capacitance as shown by Equation 9.14 (Barsotti et al. 1999):
τ = R ⋅C
(9.14)
The resistance is normally related to the resistance of the food and the treatment chamber only, since the resistance of the electrical circuit is comparatively low and can therefore be neglected. For a direct current and a treatment chamber with a uniform cross-section, Equation 9.15 is valid to describe the electrical resistance: R=
1 d ⋅ A σ (T )
(9.15)
where d (m) is the distance between the electrodes, A (m2) is the cross section where the electrical current flows and σ (S m−1) is the electrical conductivity of the food as a function of the temperature. Alternatively, Equation 9.16 can be used for any treatment chamber configuration: R=
V I (T , σ )
Figure 9.2. Voltage drop in an exponential decay pulse and pulse width determined at 36.9% of the peak voltage as a function of the temperature (calculation according to Eqs. 9.13 and 9.15).
(9.16)
where V (V) is the applied voltage and I (A) is the electrical current as a function of the temperature and the conductivity. This equation can be preferably used to estimate the treatment chamber resistance in cases where the parameters V and I are directly measured. According to Equation 9.16, the resistance is a function of the temperature and the electrical conductivity of the food. Therefore, different treatment times will result during the PEF treatment with exponential decay pulses, since the temperature is either inhomogeneous in the treatment chamber or not constant during the treatment itself. Considering a pulse generator for exponential decay pulses and a treatment chamber with parallel electrode configuration with an interelectrode gap of 3 mm and an electrode cross section of 0.0015 m2, Equation 9.13 can be used to calculate the voltage decay as a function of time, as shown in Figure 9.2 (C = 19.1 nF and V0 = 8 kV). The resulting resistance as a function of the temperature can be estimated using Equation 9.15 with σ as a linear function of the temperature. As the
pulse width is a function of the resistance, different values for the pulse width are expected to occur at different process temperatures. The higher the increase in the media conductivity with temperature, the higher the pulse width differences will be. It is clear from Figure 9.2 that the temperature is an important factor to be considered during PEF treatments in order to allow the exact characterization of the treatment parameters. To date, the changes of the treatment time as a function of the temperature have not been considered for the performance of PEF experiments using exponential decay pulses. For studies investigating the effect of PEF treatment and temperature, it is not recommendable to use exponential decay pulses. In this case the use of square wave pulses is more appropriate since the pulse width is controlled and constant with small variations in rise and fall time, depending on the media conductivity. There are no general equations relating the pulse width and fall time to media properties and temperature. The exact pulse shape should be obtained by measurements and approximated mathematically (Figure 9.3).
176
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
field strength intensity can be mainly attributed to differences in the electrode surface area. The electric field strength in a coaxial treatment chamber can be calculated according to Equation 9.18. E=
Figure 9.3. Ideal square wave pulse (solid line) and real pulse shape obtained by voltage measurement (dashed line) in a medium with an electrical conductivity of 4.7 mS/cm at 40°C.
V ⎛r ⎞ r ⋅ ln ⎜ 0 ⎟ ⎝ ri ⎠
This equation shows that the electric field strength is decreasing as a function of the radius of the treatment chamber, where r is the radius at which E is measured, r0 and ri are the radii of the inner and outer electrode surface, respectively (Bushnell et al. 1993). The uniformity of the electric field strength is improved when the difference between the inner and outer radii of the electrode surfaces is negligible compared with the inner radius (Eq. 9.19).
(r0 − ri ) << ri The equations describing the pulse shape are a function of time and can be introduced into the numerical simulation as boundary conditions for the variable voltage (V ) when a time-dependent simulation of PEF processing is desired.
9.3.2. Voltage and Electric Field Strength The electric field strength depends on the voltage, the geometry of the electrodes, and the distance between them (Zhang et al. 1995). In addition, the media conductivity and the temperature have a significant impact on the electric field strength. Considering a fluid-cross treatment chamber of parallel plates, the electric field strength can be mathematically expressed as: E=
V d
(9.17)
where E is the electric field strength (V/m), V is the applied voltage (V), and d is the interelectrode gap (m). This equation is valid when a homogeneous electric field strength distribution is assumed. In the case of a coaxial treatment chamber geometry, the electric field strength is not uniform and depends on the location where it is measured. Differences in the
(9.18)
(9.19)
The electric field strength in a co-field treatment chamber is also not homogeneous, and a different method for the calculation is necessary. According to Gerlach et al. (2008), the calculation of a conversion factor is necessary for an estimation of the electric field strength. This conversion factor relates the applied initial voltage to the resulting electric field strength. A possible way for its calculation is the estimation of an average electric field strength based on the applied voltage. As the electric field strength depends on the treatment chamber dimension and design, a conversion factor should be defined for every treatment chamber configuration. This topic is discussed in the following chapter (Chapter 10 of this book). In addition, the voltage delivered by the pulse generator is always higher than the voltage in the treatment chamber due to losses between the capacitor(s) and the treatment chamber. The voltage should be measured as close as possible to the treatment chamber in order to obtain an accurate estimation of the electric field strength (Pataro 2004).
9.3.3. Treatment Time and Residence Time The treatment time is an important parameter that should be controlled in order to avoid over- or
Chapter 9
Basics for Modeling of Pulsed Electric Field Processing of Foods
underprocessing. The treatment time (tt) is defined as the product of the number of pulses (n) and the pulse duration ( τ ): tt = n ⋅ τ
(9.20)
The pulse number is a function of the applied frequency and residence time of the product in the treatment chamber. n = f ⋅ tres
(9.21)
where f (Hz) is the frequency, which is defined as the number of pulses delivered per second, and tres (s) is the residence time. In a batch treatment, the residence time corresponds to the holding time of the sample in the treatment for the time period of the pulse application. In the case of a continuous treatment, the residence time is a function of the treatment chamber length (L) and the fluid velocity (u), and can be estimated as shown in Equation 9.22: tres =
L u
(9.22)
where L (m) is the length of the treatment chamber and u is the fluid velocity (m/s). According to Holland and Bragg (1995), a basic estimation of the fluid velocity can be calculated according Equation 9.23, considering a laminar flow of a Newtonian fluid in a pipe of circular cross section: ⎛ r2 ⎞ u = 2 ⋅ uave ⎜ 1 − 2 ⎟ ⎝ ri ⎠ uave =
Q (π ⋅ ri2 )
(9.23) (9.24)
where uave (m/s) is the volumetric average velocity, Q (m3/s) is the flow rate, and ri (m) is the internal radius. When the flow becomes turbulent, an approximation of the velocity profile can be given exemplarily by the one-seventh power velocity distribution equation. r⎞ ⎛ u = 2 ⋅ uave ⎜ 1 − ⎟ ⎝ ri ⎠
1/ 7
(9.25)
177
These equations do not consider the thermophysical properties as affected by the temperature, and Equation 9.25 is not valid in the viscous sublayer of the turbulent boundary layer. For a general approximation of the velocity profile and the calculation of an average treatment time, Equations 9.23 and 9.25 can be used. When accurate estimation of the treatment time in continuous systems is desired, more complex equations are necessary. Coupling Equations 9.14 and 9.20–9.24, the treatment time can be calculated according to Equation 9.26 for a continuous PEF treatment with exponential decay pulses in a co-field treatment chamber (Figure 9.4) where the insulator radius equals the electrode radius. t t (r ) =
f ⋅τ ⋅ L Q ⎛ r2 ⎞ 2⋅ ⋅ 1− (π ⋅ ri2 ) ⎜⎝ ri2 ⎟⎠
(9.26)
As the velocity profile depends strongly on the radial coordinate, the treatment time is also not homogeneous. It is evident that by performing continuous treatments, the treatment time should be considered and an average value and the standard deviation should be calculated. A compromise between the maximum treatment time (pipe walls) and the shortest treatment time (center of the pipe) should be found in order to guarantee a minimum treatment time necessary for a desired level of microbial inactivation. When performing inactivation kinetic studies that depend on the treatment time, it has to be taken into account that the high deviation of the residence time occurring in the above described continuous systems will not allow homogeneous conditions and limits the exact characterization of the applied treatment conditions (Meneses et al. 2010).
9.3.4. Specific Energy and Energy per Individual Pulse The energy input is a useful dose parameter for describing a PEF process since a comparison in terms of energy consumption with traditional processes
178
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Figure 9.4. Treatment time and velocity profile for a laminar fluid flow in a continuous colinear treatment chamber at an average flow rate of 5 L/h.
can be made (Puértolas et al. 2009). The specific energy is related to the pulse energy, the repetition rate of the pulses, and the mass flow rate. A basic definition of the specific energy input during continuous PEF treatments can be performed according to Equation 9.27: Wspec = Wpulse
f m
(9.27)
where Wspec (kJ/kg) is the specific energy input, Wpulse (J/pulse) is the energy per pulse, f is the frequency (Hz), and m is the mass flow rate (kg/s). For batch treatments, the term f m can be easily replaced by n m , where n is the pulse number and m (kg) is the mass of the sample in the treatment chamber. The pulse energy represents the electrical energy delivered by each electrical pulse during the PEF treatment. Depending on the pulse shape, the pulse energy can be estimated by different equations. For exponential decay pulses, it can be calculated for the discharge of the capacitor bank: Wpulse _ exp =
1 ⋅C ⋅V 2 2
(9.28)
where C is the capacity of the capacitor(s) and V is the charging voltage.
For square wave shaped pulses, the pulse energy can be determined by the current intensity, the voltage, and the pulse width according to: Wpulse _ cuad = V ⋅ I ⋅ τ
(9.29)
where I (A) is the current flowing through the media during the pulse width τ (s) as a result of the applied voltage V (V). Based on media conductivity σ and the measured electric field strength E, the specific energy input for exponential decay and rectangular pulses can be calculated by Equation 9.30 according to Heinz et al. (2003): ∞
Wspec = f
1 2 σ (T ) ⋅ E (t ) dt m
∫
(9.30)
0
Since the energy input is a function of the voltage (Eqs. 9.28 and 9.29), it is difficult to study the single effect of the electric field strength on food components or microorganisms because related changes in the energy input may affect the electric field strength impact. Considering a parallel plate treatment chamber with an interelectrode gap of 2 mm and a resistance of 150 Ohm, operating with square wave pulses of 3 μs at a voltage level between 3 and 9 kV, the resulting electric field strength will be 15 and 45 kV/cm,
Chapter 9
Basics for Modeling of Pulsed Electric Field Processing of Foods
respectively. According to Equation 9.16, the resulting electrical current is 20 and 60 Amperes, respectively. Using Equation 9.29, the following pulse energy values can be calculated: 0.18 J/pulse for the case of 15 kV/cm and 1.62 J/pulse for the case of 45 kV/cm, which means a difference of 800%. The same difference can be found by considering Equation 9.28 for exponential decay pulses. Energy differences of about 100% have been reported from microbial inactivation experiments using PEF by Saldaña et al. (2009). It is clear that the characterization of a PEF treatment by the electric field strength and the number of pulses or the treatment time without the consideration of the parameters related to the energy input (pulse energy and total specific energy input) is incomplete. In order to compare results of different research groups, different system configurations, and even different technologies, the total specific energy input can be used as a meaningful dose parameter in combination with the treatment parameters discussed earlier (Heinz et al. 2003; Jaeger et al. 2009; Puértolas et al. 2009). An additional consequence of the applied energy is the temperature increase in the sample during the PEF treatment; the higher the total energy input, the higher the temperature increase is. Not considering the pulse energy as well as the corresponding temperature increase will lead to a misinterpretation of microbial inactivation results at different electric field strength levels. The consequence of the energy input and temperature interrelations is the necessity of determining kinetic parameters depending on electric field strength at constant levels of energy input and temperature. Empirical models for microbial inactivation available in the literature with control of the energy input and the temperature are limited (Sensoy et al. 1997; Schrive et al. 2006; Fox et al. 2008; Jaeger et al. 2010). Two possibilities for controlling the energy input and temperature are: • Implementation of an additional inductance and resistance in the electrical circuit to control the pulse width and the pulse energy.
179
• Application of active cooling of the electrodes to prevent or control the temperature increase and to avoid changes in the electrical conductivity and pulse energy.
9.3.5. Treatment Temperature The treatment temperature is directly related to the electrical energy delivered into the treatment chamber, a phenomenon known as joule heating. The electrical energy (Qs) can be expressed as a function of the electric field strength (E) and the electrical conductivity (σ): Qs = σ (T ) ⋅ E ( x, y, z )
2
(9.31)
Analytical solutions for the temperature estimation have been proposed (Van den Bosch et al. 2003). Based on Equation 9.31 and a simple heat balance, the following expression can be deduced for the average temperature increase: ΔTave =
Wspec cp
(9.32)
This equation is the simplest one, which relates the average temperature increase to the energy input and heat capacity. This equation is valid when the application of a non-pulsating voltage is assumed. The temperature increase in a continuous treatment chamber can be calculated based on the energy delivered per pulse (Wpulse), the pulse frequency ( f ), the mass flow rate ( m ), and the specific heat capacity (cp) according to Equation 9.33: Wpulse ⋅ f = m ⋅ c p ⋅ (Tout − Tin )
(9.33)
The temperature occurring at a certain time t after the liquid has entered the treatment chamber (0 < t ≤ tres with tres referring to the total residence time in the treatment chamber) can be calculated according to Equation 9.34 (Jaeger et al. 2010): Tout = Tin +
Wpulse ⋅ f ⋅ tres m
(9.34)
As the temperature depends on the residence time, and the residence time is a function of the fluid velocity, strong variations can be found along the radial coordinate of the treatment chamber. Equation
180
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
9.34 is not valid for the thin layer of slow-moving flow close to the walls. An approximation of the temperature close to the wall and on the wall itself can be found in Lelieveld et al. (2007). Basically, the assumption of a pure conductive heat transport in the zone close to the wall is valid.
9.4. Relevant Food Engineering Properties for PEF Simulations Engineering properties of foods are relevant for the design and operation of equipment employed in food unit operations. Besides the application of the electric field itself, the fluid flow and heat transfer are the most important phenomena that are directly connected to the continuous PEF treatment of foods. The pressure or temperature differences as driving forces as well as the application of a difference in the electrical potential across the food material and the formation of an electric field are the basic principles of these unit operations.
9.4.1. Thermophysical Properties of Foods The PEF treatment is considered a nonthermal alternative to traditional pasteurization of liquid foods (Lelieveld et al. 2007) since the inactivation of microorganisms is based on the electromechanical mechanism of electroporation (Crowley 1973; Zimmermann et al. 1974), which allows food processing at moderate temperatures. However, when increasing the temperature an increased fluidity of the cell membrane leads to a reduced membrane stability and facilitates the electroporation process (Stanley 1991; Kanduser et al. 2008). This synergetic effect of temperature during PEF-induced inactivation can be used to improve the inactivation results and/or to reduce the required amount of costintensive electrical energy (Craven et al. 2008; Riener et al. 2008). Besides the combination of the PEF treatment and elevated treatment temperature, a further temperature increase can occur during the PEF treatment as a result of the joule heating (Lindgren et al. 2002). In both cases, temperature plays a major role during PEF processing, as temperature influences
Figure 9.5. Relative changes in thermophysical properties of water as a function of the temperature. Reference temperature of 20°C.
thermophysical properties, mainly the viscosity and, to a lesser extent, the thermal conductivity, the density, and the specific heat capacity (Figure 9.5, see also Chapter 2 of this book). The consideration of the treatment temperature (inlet temperature) and the temperature increase during PEF processing is essential not only for the interpretation of PEF results but also for the numerical simulations of electric field strength distribution and flow characteristics. The electrical conductivity, thermal conductivity, heat capacity, viscosity, density, and some other properties depend on temperature and will affect the temperature increase and temperature distribution by the joule heating during the PEF treatment in turn. Most food products are complex mixtures of many different chemical compounds. Even the water may be bound in one of several different ways which may alter its effect on the thermal properties (Lewicki 2004). Based on the composition of a food, it is possible to estimate the thermal properties such as the specific heat capacity using prediction equations considering different specific heats and the content of proteins (Xp), fats (Xf), carbohydrates (Xc), water (Xw), and ash (Xw) in the food product according to Equation 9.35 (Heldman and Singh 1981):
Chapter 9
Basics for Modeling of Pulsed Electric Field Processing of Foods
c p, food = 1.424 X c + 1.549 X p + 1.675 X f + 0.837 X a + 4.187 X w
(9.35)
For high-moisture foods, one can assume that the change in specific heat mimics the change in specific heat of water with temperature (T in °C). This can be calculated by Equation 9.36 according to (Kessler 2002): c p,water = 4.214 − 2.153 ⋅ 10 −3 ⋅ T + 3.646 ⋅ 10 −5 ⋅ T 2 − 1.4948 ⋅ 10 −7 ⋅ T 3
(9.36)
Thermal conductivity values and their measurement depend on the structure or physical arrangement of the sample (voids, nonhomogeneities, particleto-particle contact, and so on) as well as on the chemical composition. For most liquid foods, an equation based on water, protein, carbohydrate, fat, and ash content appears to be adequate. Choi and Okos (1986) developed Equation 9.37 for the calculation of the thermal conductivity of complex liquid foods depending on their composition:
λ food = 0.61 X w + 0.20 X p + 0.205 X c + 0.175 X f + 0.135 X a
(9.37)
For predicting the thermal conductivity of water depending on temperature, Equation 9.38 can be used as suggested by (Kessler 2002).
λ water = ( 568.96 + 1.88 ⋅ T − 8.2 ⋅ 10 −3 ⋅ T 2 + 6.02 ⋅ 10 −6 ⋅ T 3 ) ⋅ 10 −3
(9.38)
9.4.2. Rheological Properties Information on the rheological properties of the food products to be PEF treated is required for the proper design of the treatment chamber geometry as well as the numerical simulation of heat transfer phenomena and fluid flow. Fluid dynamics is of special importance since the flow velocity distribution in the treatment chamber determines the residence time and therefore the treatment time. Modifications of the treatment chamber geometry can be used to affect the flow behavior and to induce mixing effects that may improve the microbial inactivation as well
181
as the retention of heat-sensitive compounds (Jaeger et al. 2009). The viscosity of Newtonian fluids (such as water, milk, and clear fruit juices) is influenced by temperature and composition, but is independent of shear rate and shear history (Borwankar 1992). The rheological behavior of the fluid food plays an important role in continuous PEF treatment since it determines the fluid flow and the velocity profile. Equations describing velocity profiles can be used to examine the influence of different rheological models on the velocity distribution, and to determine the residence time distribution of the fluid particles. Since the viscosity also depends on the temperature, the control or documentation of the temperature is essential for the determination of the viscosity or for the conduction of experiments and calculations based on viscosity data. As an average value, there is about a 2% decrease in viscosity for each degree Celsius change in temperature (Lewis 1987). A product-dependent relation between viscosity and temperature has to be determined experimentally, based on empirical equations or on estimations considering hydrodynamic volumes of the component fractions. According to Bertsch (1983), the kinematic viscosity ν (mPas) of milk depends on temperature (T) and fat content Xf (in the range of 0–12%): ln ν = 3.03 ⋅ 10 −5 ⋅ T 2 − 1.813 ⋅ 10 −2 ⋅ T + 0.609 + X f ( −2.3 ⋅ 10 −6 ⋅ T 2 + 5.49 ⋅ 10 −4 ⋅ T
+ 2.06 ⋅ 10 −3 )
+ X 2f ⋅ ( 2.5 ⋅ 10 −7 ⋅ T 2 + 6.29 ⋅ 10 −5 ⋅ T + 5.42 ⋅ 10 −3 )
(9.39)
The kinematic viscosity ν can be defined by the ratio between the dynamic viscosity η and the density ρ. According to Equation 9.40, adapted from Kessler (2002), the density (kg/m3) of water changes also with temperature:
ρwater = 1000.22 + 1.0205 ⋅ 10 −2 ⋅ T − 5.8149 ⋅ 10 −3 ⋅ T 2 + 1.496 ⋅ 10 −5 ⋅ T 3
(9.40)
182
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Additional, detailed information on physical properties can be found in Bertsch (1983) for milk or in Constenla et al. (1989) for fruit juice.
9.4.3. Electrical Properties of Food The electric behavior of liquid foods is dependent not only on the chemical composition such as the content of water, fat, protein, carbohydrates, and minerals but also on the effects of dissolved and suspended solids that the liquid may contain. Small particle sizes, as in the case of orange or tomato juice (homogeneous distribution), or products with randomly dispersed solids of relatively large particle size such as vegetable soup (heterogeneous) may occur. Although the overall (volumetric) electrical properties of homogeneous and heterogeneous systems of similar moisture, dissolved salts, and suspended solids content may be nearly identical, the behavior during PEF treatment is different with respect to effects of particle size, homogeneity, and distribution. The electrical properties of foods such as electrical conductivity and ionic strength are of key relevance for PEF treatment since they determine the maximum applicable electric field intensity as well as the current flow. The coupling and distribution of the electric field strength, the energy, and the product’s heating is based on the electrical food properties. The mechanism or mode of energy transfer from the electric field to the product is the energy dissipation caused by joule heating, which couples electrical and thermal food properties. The electrical conductivity of a medium, defined as the ability to conduct electric current, is given in Siemens per meter or the inverse of the resistivity ρe, given in Ωm. The electrical conductivity of liquid food is caused by the presence of ions and shows a linear relation to temperature. The thermal conductivity for different liquid food systems as a function of the temperature is shown in Figure 9.6, and the linear relationships σ(T) are given in Table 9.1. Food conductivity ranges from σ = 0.6 mS/cm (tap water) or even below for pure fats and oils to
Figure 9.6. Relation between electrical conductivity and temperature of different liquid food systems. Adapted from Toepfl et al. (2007).
Table 9.1. Coefficients a and b for the linear relationship of the conductivity σ and the temperature T (σ = aT + b) for different beverages according to Toepfl (2004). Product Apple juice Red grape juice Orange juice Tomato juice Carrot juice Milk (3.5 % fat)
a (mS cm−1°C−1)
b (mS cm−1)
0.037761 0.060964 0.069500 0.316900 0.141250 0.080119
1.38071 1.11286 1.53000 3.31000 2.77500 2.37714
values in excess of σ = 7 mS/cm for milk ultrafiltrates and other high-conductivity products (Barsotti et al. 1999). Treatment chambers with high electrically conductive foods have a poor resistance, and it is necessary to produce higher voltages to achieve the same effect of microbiological inactivation that is achieved during processing of low-conductive foods. It is also more difficult to build sufficient field strength when the conductivity is too high (Wouters et al. 2001). To obtain the same degree of microbiological inactivation in foods with very different conductivity, the treatment conditions, such as the interlectrode gap
Chapter 9
Basics for Modeling of Pulsed Electric Field Processing of Foods
in the treatment chamber, the pulse width, and the voltage, have to be adapted. On the other hand, the presence of ions appears to be necessary to increase the transmembrane potential (Bruhn et al. 1998). The membrane will be weakened and will be more susceptible to an electric pulse in media with higher ionic strength, causing higher permeability and structural changes. However, the bactericidal effect of PEF is inversely proportional to the ionic strength of the suspension; that is, the inactivation is generally enhanced when the medium has a high electric resistivity (Huelsheger et al. 1981; Mizuno and Hori 1988). Liquid or semisolid foods containing suspended phases (i.e., solid particles, air bubbles, or large fat globules) with significantly different properties from those of the continuous phase will be considered heterogeneous. The electric behavior of one phase is essentially different from another phase, resulting in different electric field strength distribution as well as joule heating rates. Figure 9.7 illustrates the impact
of agglomeration of microbial cells and the attachment of microbial cells to fat globules (insulating particles) with completely different electrical properties from the surrounding media on the electric field strength distribution. The numerical simulation conducted by Toepfl et al. (2007) for an external electric field strength of 12.5 kV/cm showed that the peak values for the critical electric field strength were reduced by agglomeration and insulating particles to 84% and 45%, respectively. This fact limits the lethality of the PEF process since the required membrane potential for an electroporation is not reached. Similar effects will occur when the media contains electrically insulating gas bubbles, which can be a result of electrolysis at the electrodes (Gongora-Nieto et al. 2003).
9.4.4. PEF Processing Unit—Relevant Thermophysical Properties Since the thermophysical properties as well as the electrical and rheological properties are dependent on temperature, it is essential to determine the temperature during PEF processing. This includes the temperature during preheating, the temperature increase during PEF treatment due to the joule heating, and the temperature decrease during subsequent cooling steps (Jaeger et al. 2010). The heat transfer coefficient (U) for the heat exchanger in use (either heating or cooling) can be determined experimentally and calculated according to Equation 9.41, where m is the mass flow rate, cp is the specific heat capacity, Tin and Tout are the inlet and outlet temperatures of the product, A is the area for the heat transfer, and ΔTlog is the logarithmic mean temperature difference between the inside and outside (Text) of the heat exchanger. m ⋅ c p ⋅ (Tin − Tout ) = U ⋅ A ⋅ ΔTlog
Figure 9.7. Distribution of the electric field strength and impact on the critical electric field strength for electroporation of microbial cells when attached to each other (case A: agglomeration) or attached to insulating particles (case B: fat globule). Adapted from Toepfl et al. (2007). See color insert.
183
(9.41)
For the implementation of the heat transfer phenomena in the numerical simulation, the outer convective heat transfer coefficient (αo) may be required. The inner convective heat transfer coefficient (αi) can be calculated based on the Nusselt, Reynolds, and Prandtl values (Martin 2002). Together with the overall heat transfer coefficient (U), the inner
184
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Figure 9.8. Temperature–time profile (line 1 and line 2 with lower specific energy input) for a PEF processing including preheating (A), an intermediate pipe section (B), the PEF treatment (C), an intermediate pipe section (D), and the cooling (E). Lines 3 and 4 represent exemplarily the corresponding thermal inactivation of a heat-sensitive microorganism in the different sections of the equipment. Adapted from Jaeger et al. (2010).
convective heat transfer coefficient (αi), and the conductive heat transfer coefficient (λ), which depends on the material of the heat exchanger with the wall thickness (s), the outer convective heat transfer coefficient (αo) can be calculated based on Equation 9.42: U=
1 1 s 1 + + αi λ αo
(9.42)
Implementation of the known characteristics for the heat transfer in numerical simulation software packages allows the simulation of the temperature during the heating and cooling processes. Equation 9.34 of Section 9.3.5 and the equations obtained for a particular heat exchanger system are combined to calculate the temperature–time profile of a liquid during pre-heating, PEF treatment, and cooling, which is shown in one example in Figure 9.8. The obtained temperature–time profile is the basis for the consideration of temperature-dependent physical properties of foods as well as for the differentiation of thermal inactivation effects occurring during PEF treatment (Jaeger et al. 2010).
9.5. Selected Inactivation Models for Numerical Simulations Since the numerical simulation of PEF processing allows a detailed description of small changes of a variable, such as the electric field strength as a function of the treatment chamber geometry, or even the changes of the fluid velocity as altered by temperature changes, it is important to use an adequate microbial/enzyme inactivation model, capable to represent the dependency of the inactivation on the electric field strength and the treatment time with sufficient accuracy. The main process conditions considered here are the electric field strength and the treatment time. Selected models appropriate for numerical simulations are exclusively obtained under homogeneous treatment conditions. Since the electric field strength is homogeneous only in a treatment chamber with parallel plate electrode configuration, models performed in colinear or coaxial treatment chambers will not be considered in this section. Additionally, only models performed in batch systems will be discussed since the treatment time in a continuous treatment chamber is not homogeneous as discussed in Section 9.3.3.
Chapter 9
Basics for Modeling of Pulsed Electric Field Processing of Foods
9.5.1. Kinetic Models for Microbial Inactivation The main mechanism of PEF inactivation is related to the electroporation of the cell membrane (Zimmermann et al. 1974; Zimmermann 1986). Mechanistic models for the microbial inactivation by PEF have not yet been combined with kinetic models to one single predictive model that is capable to describe the expected microbial inactivation based on the mechanism of inactivation. In contrast to this, several empirical models have been developed; numerous experimental results have been fitted to proposed kinetic models, mainly to describe the evolution of the microbial inactivation as a function of the electric field strength and treatment time. For a detailed description of the mechanism of microbial inactivation by PEF, see Barbosa-Cánovas et al. (1999) and Lelieveld et al. (2007). A detailed description on kinetic models can be found in Álvarez et al. (2007). Empirical models based on Huelsheger et al. (1981) and Peleg (1995) and those that follow a Weibull distribution (Weibull 1951; Van Boekel 2002) have been used to model the microbial inactivation by PEF. An example of different models is given below. Model A. First order exponential decay: S (t ) = e − kt
(9.43)
Model B. Huelsheger et al. (1981): ⎛t⎞ S (t ) = ⎜ ⎟ ⎝ tc ⎠
− ( E − Ec ) k
(9.44)
where S is the survival rate (N/N0), t is the treatment time, tc is the critical treatment time, E is the electric field strength, Ec is the electric field strength at the extrapolated survival fraction of 100%, and k is a constant characteristic of each microorganism. Model C. Peleg (1995). Based on Fermi’s equation: S (t ) =
1 ⎡ ( E − E c ( n )) ⎤ 1 + exp ⎢ k ( n ) ⎥⎦ ⎣
(9.45)
185
Ec(n) is the electric field strength at which the survival level is 50% and k(n) is a kinetic constant that describes the steepness of the sigmoid curve. Ec(n) and k(n) depend on both the number of pulses and the treatment time. Model D. Weibull distribution (Weibull 1951): ⎛ t⎞ S (t ) = exp ⎜ − ⎟ ⎝ δ⎠
α
(9.46)
In addition to these models, alternative equations have been used. The existence of two populations of microorganisms (PEF-sensitive and PEF-resistant subpopulations) can be described by an extension of the exponential model (Pruitt and Kamau 1993; Amiali et al. 2004). Models E and F: S (t ) = β0 + (1 − β0 ) ⋅ e − β2 t
(9.47)
S (t ) = β0 e − β1t + (1 − β0 ) ⋅ e − β2 t
(9.48)
where S(t) is the fraction of total survivors; t is the treatment time (μs); β0 is the fraction of survivors in population 1 (generally related to the PEFsensitive population); β1 is the specific death rate of subpopulation 1; and β2 is the specific death rate of subpopulation 2. Model G. Sigmoidal equations in PEF have been used (Álvarez et al. 2003d) and also applied for thermal inactivation studies (Augustin et al. 1998):
(
S (t ) = 1 + e(tlog − tc ,log )
sd 2
) −1
(9.49)
This model is justified based on a distribution of the PEF sensitivity within the bacterial population. S(t) is the fraction of total survivors; tlog is the log10 of the treatment time (μs); tc,log is the log10 of the time necessary to inactivate 50% of the population (μs); and sd is a parameter proportional to the standard deviation of the PEF resistance (μs0.5). Model H describes upward concave curves. (Peleg and Penchina 2000; Álvarez et al. 2003a): log10 S (t ) = − k ln (1 − k1t )
(9.50)
where S(t) is the survival fraction; t is the treatment time (μs); and k and k1 are characteristic parameters of the equation.
186
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Model I. A log-log model consisting of a linear regression of the log10 of the survival fraction of microoganisms versus the log10 of the treatment time (Raso et al. 2000). Model G. The log-logistic model (Cole et al. 1993; Raso et al. 2000): log10 S (t ) = k1 + ( k2 − k1 ) / 1
+ exp [ 4 k3 ( k4 − log10 t ) / ( k2 − k1 )] (9.51)
where k1 is the upper asymptote log CFU/mL, k2 is the lower asymptote, k4 is the position of the maximum slope, and k3 is the maximum slope. Table 9.2 summarizes the selected models, which are suitable for numerical simulations. The range of
the treatment parameters for which the model was applied (electric field strength, treatment time, and temperature) is also indicated.
9.5.2. Kinetic Models for Enzyme Inactivation The mechanism of enzyme inactivation is still unclear; many authors assume that PEF affects the native structure of the enzyme, which could result in changes of its activity. Possible theories on enzyme inactivation mechanisms can be found in Martín-Belloso and Elez-Martínez (2005), in which different kinetic models for enzyme inactivation by PEF are shown. A review on enzyme inactivation
Table 9.2. Selected models for the microbial inactivation by PEF. Batch system with parallel plate electrode configuration.
Model
Microorganism
Product
A, I and G
Salmonella senftenberg
Citrate–phosphate McIlvaine buffer (pH 7; 2 mS/cm)
D D
Salmonella serovar Enteritidis and Salmonella serovar Typhimurium Listeria monocytogenes
D
Yersinia enterocolitica
D, F, G and H
Escherichia coli
E and F
Escherichia coli
D
Lactobacillus plantarum
D
Listeria monocytogenes
D
Dekkera anomala, Dekkera bruxellensis, Lactobacillus hilgardii, and Lactobacillus plantarum
Citrate–phosphate McIlvaine buffer (pH 7; 2, 3, 4 mS/cm) Citrate–phosphate McIlvaine buffer (pH 3.8, 5.4; 7, 2 mS/cm) Citrate–phosphate McIlvaine buffer (pH 7; 2 mS/cm) Whole egg (pH 7.8), egg yolk (pH 6.4) and egg white (pH 8.3) Citrate–phosphate McIlvaine buffer (pH 3.5–7.0; 2 mS/cm) Citrate–phosphate McIlvaine buffer (pH 3.5–7.0; 2 mS/cm) Wine (2.02 ± 0.22 mS/cm) and must (1.97 ± 0.23 mS/cm)
Electric field strength, treatment time and temperature 12–28 kV/cm 10–2,000 pulses <35°C 15–28 kV/cm 15–28 kV/cm 0–2,000 μs <32°C 5.5–28 kV/cm 1–15 μs <35°C 15–28 kV/cm 0–2,000 μs <35°C 15 kV/cm 20–100 ms 0°C 12–25 kV/cm 0–1,000 μs <35°C 15–28 kV/cm 10–1,000 μs <35°C 16–31 kV/cm 10–100 pulses <30°C
Author Raso et al. (2000) Álvarez et al. (2003a) Álvarez et al. (2003b) Álvarez et al. (2003c) Álvarez et al. (2003d) Amiali et al. (2004) Gómez et al. (2005a) Gómez et al. (2005b) Puértolas et al. (2009)
Chapter 9
Basics for Modeling of Pulsed Electric Field Processing of Foods
by PEF treatments can be found in Van Loey et al. (2001). The single impact of different PEF parameters, such as electric field strength, treatment time, energy input, and temperature on enzyme inactivation has not been clearly identified and implemented in kinetic equations. In addition, differences in experimental setups, such as media properties and treatment chamber geometries, complicate the understanding of possible mechanisms for the enzyme inactivation by PEF. Nevertheless, several empirical models have been used and successfully validated with experiments. A first approach for differentiating between pure thermal and PEF effects occurring simultaneously in a continuous treatment chamber can be found in Jaeger et al. (2009, 2010). The number of kinetic models for the inactivation of enzymes suitable for numerical simulations is even more limited than for the models describing the microbial inactivation. Table 9.3 summarizes the models, which were obtained under homogeneous
187
distributions of the electric field strength and the treatment time (parallel plate electrode configuration and batch system).
9.6. Conclusion and Outlook The aspects discussed in this chapter pointed out the main basic principles for the numerical simulation of the PEF process as well as for the implementation of numerous additional physical properties of the food material and the treatment chamber. The potential of numerical simulations to combine the kinetic models with simulated characteristics of a distinct PEF treatment in order to predict occurring processing effects was shown. The Multiphysics nature of PEF processing does not only require the consideration of phenomena related to mass transfer, heat transfer, and the electrical field effects, but does also need to take into account the dependency of physical media properties as affected by the above mentioned interrelations. It was pointed out that a complete characterization of a PEF treatment needs to include
Table 9.3. Selected models for the inactivation of enzymes by PEF. Model
Enzyme
Origin/product
First-order Huelsheger based on Fermi
PME
Extract from tomato (0.945 ± 0.01 mS/cm)
First-order
PPO
First-order
PPO
Extracts from apple (2.27 mS/cm) and pear (2.42 mS/cm) Extract from peach
First-order
PG
First-order
LP
First-order Huelsheger based on Fermi Weibull
PE
Enzyme solution in distilled water (13 mS/cm) Pseudomonas fluorescens in SMUFa Aqueous solution (0.4 mS/cm and pH 4.6)
Electric field strength, treatment time, and temperature 5–24 kV/cm 50–400 pulses 4–15°C 5.52–24.6 kV/cm 0–8 ms 4–15°C 2.18–24.30 kV/cm 0–30 ms 4–25°C 5.18–19.39 kV/cm 0–400 pulses 4–25°C 16.4–27.4 kV/cm 10–80 pulses 18–34°C 19–38 kV/cm 0–463 μs 4–37.2°C
Author Giner et al. (2000) Giner et al. (2001) Giner et al. (2002) Giner et al. (2003) Bendicho et al. (2002) Giner et al. (2005)
a SMUF, simulated skim milk ultrafiltrate. PME, pectin metylesterase; PG, polygalacturonase; LP, lipase; PE, pectinesterase; PME, pectin metylesterase; PPO, polyphenoloxidase.
188
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
energy parameters such as pulse energy and total specific energy input apart from treatment time or pulse number in order to distinguish accurately between the impact of these factors on the inactivation of microorganisms or the alteration of food compounds. The implementation of kinetic models obtained under defined treatment conditions into the numerical simulation of PEF treatment systems will be key to further characterizing the underlying mechanisms and the optimization of processing units.
Acknowledgments The authors would like to thank the German Ministry of Economics and Technology (via AiF) and the FEI (Forschungskreis der Ernährungsindustrie e.V., Bonn), Project AiF 15610 N and the Commission of the European Communities, Framework 6, Priority 5 “Food Quality and Safety,” Integrated Project NovelQ FP6-CT-2006-015710. Nicolás Meneses gratefully acknowledges the financial support from DAAD (German Academic Exchange Service) and Universidad Austral de Chile, Valdivia, Chile, for the initial period of the work.
Notation Latin Variables A C ci cp c p,water c p, food Di d E Ec F f H1 H2 I J
Surface Capacitance Concentration of substance or specie i Specific heat capacity Specific heat capacity of water Specific heat capacity of food Diffusion coefficient of specie i Inter electrode gap Electric field strength Critical electric field strength Volumetric force vector Frequency or pulse repetition rate Heaviside step function 1 Heaviside step function 2 Electrical current Current density
Je k L m m n p r ri ro R RA Rc s S Q Qs ΔTave ΔTlog T Tin Text Tout t tc tc,log tlog tr tt U u uave Wpulse Wpulse_cuad Wpulse_exp Wspecific Xa Xc Xf Xp Xw V V0
Externally generated current density Model kinetic constant Length Mass Mass flow rate Number of pulses Pressure Radius Inner radius Outer radius Resistance Relative activity Treatment chamber resistance Wall thickness Microbial survival rate Flow rate Source term Average temperature difference Logarithmic mean temperature difference Temperature Inlet temperature Exterior temperature Outlet temperature Time Critical treatment time Log10 of the critical treatment time Log10 of the treatment time Residence time Treatment time Overall heat transfer coefficient Velocity vector Average velocity Energy per pulse Energy per pulse for quadratic pulses Energy per pulse for exponential pulses Specific energy input Content of ash Content of carbohydrates Content of fat Content of proteins Content of water Electric potential Initial voltage
Chapter 9
Basics for Modeling of Pulsed Electric Field Processing of Foods
Greek Variables ∇ ∂ ∂t α αi αo β0 β1 β2 λ λ water λ food η π ρ ρe ρwater σ τ ν
Gradient operator Partial derivative Kinetic constant of Weibull model Inner convective heat transfer coefficient Outer convective heat transfer coefficient Fraction of survivors in population 1 Specific death rate of subpopulation 1 Specific death rate of subpopulation 2 Thermal conductivity Thermal conductivity of water Thermal conductivity of food Dynamic viscosity Pi Density Electrical resistivity Density of water Electrical conductivity Pulse width Kinematic viscosity
References Álvarez I, Condón S, Sala FJ, Raso J. 2003a. Resistance variation of Salmonella enterica serovars to pulsed electric fields treatments. J Food Sci 68:2316–2320. Álvarez I, Pagán R, Condón S, Raso J. 2003b. The influence of process parameters for the inactivation of Listeria monocytogenes by pulsed electric fields. Int J Food Microbiol 87:87–95. Álvarez I, Raso J, Sala FJ, Condón S. 2003c. Inactivation of Yersinia enterocolitica by pulsed electric fields. Food Microbiol 20:691–700. Álvarez I, Virto R, Raso J, Condón S. 2003d. Comparing predicting models for the Escherichia coli inactivation by pulsed electric fields. Innov Food Sci Emerg Technol 4:195–202. Amiali M, Ngadi M, Raghavan V, Smith J. 2004. Inactivation of Escherichia coli, O157:H7 in liquid dialyzed egg using pulsed electric fields. Food Bioproducts Process 82(C2):151–156. Álvarez I, Condón S, Raso J. 2007. Microbial inactivation by pulsed electric field. In: J Raso, V Heinz, eds., Pulsed Electric Fields Technology for the Food Industry, 98–198. New York: Springer. Augustin JC, Carlier V, Rozier J. 1998. Mathematical modelling of the heat resistance of Listeria monocytogenes. J Appl Microbiol 84:185–191. Barbosa-Cánovas GV, Góngora-Nieto MM, Pothakamury UR, Swanson BG. 1999. Preservation of Foods with Pulsed Electric Fields. San Diego: Academic Press.
189
Barsotti L, Merle P, Cheftel JC. 1999. Food processing by pulsed electric fields: 1. Physical effects. Food Rev Int 15(2): 163–180. Bendicho S, Estela C, Giner J, Barbosa-Cánovas GV, Martín O. 2002. Effects of high intensity pulsed electric field and thermal treatments on a lipase from Pseudomonas fluorescens. J Dairy Sci 85:19–27. Bertsch AJ. 1983. Surface tension of whole and skim-milk between 18 and 135°C. J Dairy Res 50:259–267. Beveridge J, MacGregor S, Marsili L, Anderson J, Rowan N, Farish O. 2002. Comparison of the effectiveness of biphase and monophase rectangular pulses for the inactivation of micro-organisms using pulsed electric fields. IEEE Trans Plasma Sci 30(4):1525–1531. Borwankar RP. 1992. Food texture and rheology: A tutorial review. J Food Eng 16(1/2):1–16. Bruhn RE, Pedrow PD, Olsen RG, Barbosa-Canovas GV, Swanson BG. 1998. Heat conduction in microbes exposed to pulsed electric fields. IEEE Trans Dielectr Electr Insul 5(6):878–885. Bushnell AH, Dunn JE, Clark RW, Pearlman JS. 1993. High pulsed voltage system for extending the shelf life of pumpable food products. U.S. patent 5,235,905. Choi Y, Okos MR. 1986. Thermal properties of liquid foods—A review. In: MR Okos, ed., Physical and Chemical Properties of Food, 35–77. Michigan: American Society of Agricultural Engineers. Cole MB, Davies KW, Munro G, Holyoak CD, Kilsby DC. 1993. A vitalistic model to describe the thermal inactivation of Listeria monocytogenes. J Ind Microbiol 12:232–239. Constenla DT, Lozano JE, Crapiste GH. 1989. Thermophysical properties of clarified apple juice as a function of concentration and temperature. J Food Sci 54(3):663–668. Craven HM, Swiergon P, Ng S, Midgely J, Versteeg C, Coventry MJ, Wan J. 2008. Evaluation of pulsed electric field and minimal heat treatments for inactivation of pseudomonads and enhancement of milk shelf-life. Innov Food Sci Emerg Technol 9(2):211–216. Crowley JM. 1973. Electrical breakdown of bimolecular lipid membranes as an electromechanical instability. Biophys J 13:711–724. Ferziger JH, Peric M. 2002. Computational Methods for Fluid Dynamics. Berlin: Springer. Fiala A, Wouters P, van den Bosch E, Creyghton Y. 2001. Coupled electrical-fluid model of pulsed electric field treatment in a model food system. Innov Food Sci Emerg Technol 2:229–238. Fox M, Esveld D, Mastwijk H, Boom R. 2008. Inactivation of L. plantarum in a PEF microreactor. The effect of pulse width and temperature on the inactivation. Innov Food Sci Emerg Technol 9:101–108. Gerlach D, Alleborn N, Baars A, Delgado A, Moritz J, Knorr D. 2008. Numerical simulations of pulsed electric fields for food preservation: A review. Innov Food Sci Emerg Technol 9:408–417.
190
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
Giner J, Gimeno V, Espachs A, Elez P, Barbosa-Cánovas G, Martín O. 2000. Inhibition of tomato (Licopersicon esculentum Mill.) pectin methylesterase by pulsed electric fields. Innov Food Sci Emerg Technol 1(1):57–67. Giner J, Gimeno V, Barbosa-Cánovas G, Martín O. 2001. Effects of pulsed electric field processing on apple and pear polyphenoloxidases. Food Sci Technol Int 7(4):339–345. Giner J, Ortega M, Mesegué M, Gimeno V, Barbosa-Cánovas G, Martín O. 2002. Inactivation of peach polyphenoloxidase by exposure to pulsed electric fields. J Food Sci 67(4):1467–1472. Giner J, Gimeno V, Palomes M, Barbosa-Cánovas GV, Martín O. 2003. Lessening polygalacturonase activity in a commercial enzyme preparation by exposure to pulsed electric fields. Eur Food Res Technol 217:43–48. Giner J, Grouberman P, Gimeno V, Martín O. 2005. Reduction of pectinesterase activity in a commercial enzyme preparation by pulsed electric fields: Comparison of inactivation kinetic models. J Sci Food Agric 85:1613–1621. Gómez N, García D, Álvarez I, Condón S, Raso J. 2005a. Modeling inactivation of Listeria monocytogenes by pulsed electric fields. Int J Food Microbiol 103:199–206. Gómez N, García D, Álvarez I, Raso J, Condón S. 2005b. A model describing the kinetics of inactivation of Lactobacillus plantarum in a buffer system of different pH and in orange and apple juice. J Food Eng 70:7–14. Gongora-Nieto M, Pedrow PD, Swanson BG, Barbosa-Canovas GV. 2003. Impact of air bubbles in a dielectric liquid when subjected to high electric field strengths. Innov Food Sci Emerg Technol 4:57–67. Heinz V, Toepfl S, Knorr D. 2003. Impact of temperature on lethality and energy efficiency of apple juice pasteurization by pulsed electric fields treatment. Innov Food Sci Emerg Technol 4(2):167–175. Heldman DR, Singh RP. 1981. Food Process Engineering. Westport: Avi Publishing. Ho S, Mittal GS. 2000. High voltage pulsed electrical field for liquid food pasteurization. Food Rev Int 16(4):395–434. Holland FA, Bragg R. 1995. Fluid Flow for Chemical Engineers, 2nd ed. London: Elsevier. Huelsheger H, Potel J, Niemann EG. 1981. Killing of bacteria with electric pulses of high field strength. Radiat Environ Biophys 20:53–65. Jaeger H, Meneses N, Knorr D. 2009. Impact of PEF treatment inhomogeneity such as electric field distribution, flow characteristics and temperature effects on the inactivation of E. coli and milk alkaline phosphatase. Innov Food Sci Emerg Technol 10(4):470–480. Jaeger H, Meneses N, Moritz J, Knorr D. 2010. Model for the differentiation of temperature and electric field effects during thermal assisted PEF processing. J Food Eng (in press). Kanduser M, Sentjurc M, Miklavcic D. 2008. The temperature effect during pulse application on cell membrane fluidity and permeabilization. Bioelectrochemistry 74(1):52–57.
Kessler HG. 2002. Food and Bio Process Engineering. München: Verlag A. Kessler. Lelieveld HLM, Notermans S, de Haan SWH, eds. 2007. Food Preservation by Pulsed Electric Fields. Abington: Woodhead Publishing. Lewicki PP. 2004. Water as the determinant of food engineering properties. A review. J Food Eng 61(4):483–495. Lewis MJ. 1987. Physical Properties of Foods and Food Processing Systems. Weinheim: VCH Verlagsgesellschaft. Lindgren M, Aronsson K, Galt S, Ohlsson T. 2002. Simulation of the temperature increase in pulsed electric field (PEF) continuous flow treatment chambers. Innov Food Sci Emerg Technol 3:233–245. Loeffler M. 2006. Generation and application of high intensity pulsed electric fields. In: J Raso, V Heinz, eds., Pulsed Electric Fields Technology for the Food Industry, 27–72. Heidelberg: Springer-Verlag. Martin H. 2002. Dimensionslose Kenngrößen. In: VD Ingenieure, ed., VDI Wärmeatlas. Heidelberg: Springer-Verlag. Martín O, Zhang Q, Castro AJ, Barbosa-Cánovas GV, Swanson BG. 1994. Pulsed electric fields of high voltage to preserve foods. Microbiological and engineering aspects of the process. Span J Food Sci Technol 34:1–3. Martín-Belloso O, Elez-Martínez P. 2005. Enzymatic inactivation by pulsed electric fields. In: D-W Sun, ed., Emerging Technologies for Food Processing, 155–181. London: Academic Press. Meneses N, Jaeger H, Moritz J, Knorr D. 2010. Impact of insulator shape and flow characteristics on inactivation of E. coli using a continuous co-linear PEF system. J Food Eng (in press). Mizuno A, Hori Y. 1988. Destruction of living cells by pulsed high-voltage application. IEEE Trans Ind Appl 24(3): 387–394. Pataro G. 2004. The utilization of pulsed electric fields in food stabilization. PhD dissertation, University of Salermo, Salermo. Peleg M. 1995. A model of microbial survival after exposure to pulsed electric fields. J Sci Food Agric 67:93–99. Peleg M, Penchina CM. 2000. Modelling microbial survival during exposure to lethal agent varying intensity. Crit Rev Food Sci Nutr 40(2):159–172. Pruitt K, Kamau DN. 1993. Mathematical models of bacteria growth, inhibition and death under combined stress conditions. J Ind Microbiol 12:221–231. Puértolas E, López N, Condón S, Raso J, Álvarez I. 2009. Pulsed electric fields inactivation of wine spoilage yeast and bacteria. Int J Food Microbiol 130:49–55. Raso J, Álvarez I, Condón S, Sala FJ. 2000. Predicting inactivation of Salmonella senftenberg by pulsed electric fields. Innov Food Sci Emerg Technol 1:21–30. Riener J, Noci F, Cronin DA, Morgan DJ, Lyng JG. 2008. Combined effect of temperature and pulsed electric fields on apple juice peroxidase and polyphenoloxidase inactivation. Food Chem 109(2):402–407.
Chapter 9
Basics for Modeling of Pulsed Electric Field Processing of Foods
Saldaña G, Puértolas E, López N, García D, Álvarez I, Raso J. 2009. Comparing the PEF resistance and occurrence of sublethal injury on different strains of Escherichia coli, Salmonella Typhimurium, Listeria monocytogenes and Staphylococcus aureus in media of pH 4 and 7. Innov Food Sci Emerg Technol 10:160–165. Schrive L, Grasmick A, Moussiere S, Sarrade S. 2006. Pulsed electric field treatment of Saccharomyces cerevisiae suspensions: A mechanistic approach coupling energy transfer, mass transfer and hydrodynamics. Biochem Eng J 27:212–224. Sensoy I, Zhang Q, Sastry S. 1997. Inactivation kinetics of Salmonella Dublin by pulsed electric field. J Food Process Engineering 20(5):367–381. Stanley DW. 1991. Biological membrane deterioration and associated quality losses in food tissues. In: FM Clydesdale, ed., Critical Reviews in Food Science and Nutrition, New York: CRC Press. Toepfl S. 2004. Erhöhung des letalen Effektes gepulster elektrischer Felder bei der Inaktivierung ausgwählter Mikroorganismen durch Variation der Impulscharakteristik. Diploma thesis, Berlin University of Technology, Berlin. Toepfl S, Heinz V, Knorr D. 2007. High intensity pulsed electric fields applied for food preservation. Chem Eng Process 46:537–546. Tsong TY. 1990. Voltage modulation of membrane permeability and energy utilization in cells. Biosci Rep 3:487–505. Van Boekel MAJS. 2002. On the use of the Weibull model to
191
describe thermal inactivation of microbial vegetative cells. Int J Food Microbiol 74:139–159. Van Boekel M. 2009. Kinetic Modeling of Reactions in Foods. Boca Raton, FL: CRC Press/Taylor & Francis. Van den Bosch H, Morshuis P, Smit J. 2003. Temperature distribution in continuous fluid flows treated by PEF. Paper read at XIII International Symposium on High Voltage (ISH), Delft, the Netherlands. Van Loey A, Verachtert B, Hendrickx M. 2001. Effects of high electric field pulses on enzymes. Trends Food Sci Technol 12:94–102. Weibull W. 1951. A statistical distribution function of wide applicability. J Appl Mech 51:293–297. Wouters PC, Álvarez I, Raso J. 2001. Critical factors determining inactivation kinetics by pulsed electric field food processing. Trends Food Sci Technol 12(3–4):112–121. Zhang Q, Barbosa-Cánovas GV, Swanson BG. 1995. Engineering aspects of pulsed electric field pasteurization. J Food Eng 25:261–281. Zimmermann U. 1986. Electric breakdown, electropermeabilization and electrofusion. Rev Physiol Biochem Pharmacol 105:175–256. Zimmermann U, Pilwat G, Riemann F. 1974. Dielectric breakdown in cell membranes. Biophys J 14:881–899. Zimmermann U, Pilwat G, Beckers F, Riemann F. 1976. Effects of external electrical fields on cell membranes. Bioelectrochem Bioenerg 3:58–83.
Chapter 10 Computational Fluid Dynamics Applied in Pulsed Electric Field Preservation of Liquid Foods Nicolás Meneses, Henry Jaeger, and Dietrich Knorr
10.1. Introduction Pulsed electric field (PEF) treatment can be considered a nonthermal food preservation technology since the microbial inactivation mechanism is based on electroporation (Knorr et al. 1994). Nevertheless, due to the electrical conductivity of the food material, a substantial current will flow as an unwanted side effect during the application of the high voltage (Raso and Heinz 2006). To reduce the energy consumption and to limit the product heating, a treatment chamber with a high electrical resistance is desired. This parameter is of outstanding importance in the case of treating products with high electrical conductivity, where a high electrical current flow will lead to increased joule (ohmic) heating effects and an unwanted temperature increase. Many authors (Fiala et al. 2001; Lindgren et al. 2002; Van den Bosch et al. 2002; Gerlach et al. 2008) have described the temperature distribution in a PEF treatment chamber and reported the occurrence of high local temperatures due to the inhomogeneous distribution of the electrical field, limited flow velocity, and recirculation of the liquid. These temperatures are only detectable by numerical simulations since temperature measurement in the small
volume of the treatment chamber is hardly feasible without interference of the measuring device with the flow and the electric field. Treatment homogeneity in terms of homogeneous electric field distribution as well as residence and treatment time of the product and uniform temperature distribution presents the most challenging aspect during the design of a treatment chamber (Lindgren et al. 2002; see also Chapter 9 of this book). In this chapter the application of computational fluid dynamics using commercial software packages for simulating PEF processing is discussed. The first section gives an overview on different treatment chamber configurations and validation methods of numerical simulations used by different research groups. The second section covers the topic of transient simulation of PEF processing in batch systems. The third section deals with the steady-state simulation of PEF and the comparison of two different treatment chamber setups focusing on electric field strength, temperature, and velocity profiles. The numerical background on how to carry out a simulation using a commercial software package is an important aspect and therefore included in each
Innovative Food Processing Technologies: Advances in Multiphysics Simulation, First Edition. Edited by Kai Knoerzer, Pablo Juliano, Peter Roupas, and Cornelis Versteeg. © 2011 by John Wiley & Sons, Ltd. and Institute of Food Technologists. Published by John Wiley & Sons, Ltd. ISBN: 978-0-813-81754-5
193
194
Innovative Food Processing Technologies: Advances in Multiphysics Simulation
section of this chapter. Governing equations, already shown in detail in the previous chapter (Chapter 9 of this book), the implementation of boundary conditions, and thermophysical properties of liquid food, the numerical grid, and solution methods will be explained, followed by a presentation of methods for the experimental validation. The insertion of static mixing devices in the treatment chamber is presented in order to