Biofilm Reactors
Prepared by the Biofilm Reactors Task Force of the Water Environment Federation® Rhodes R. Copithorn, P.E., BCEE, Chair Joshua P. Boltz, Ph.D., P.E. Christine deBarbadillo, P.E. Paul Dombrowski, P.E., BCEE John R. Harrison, P.E. Sarah Hubbell Joseph A. Husband, P.E., BCEE Samuel Jeyanayagam, Ph.D., P.E., BCEE Ishin Kaya, P.Eng. Carl M. Koch, Ph.D., P.E., BCEE David J. Krichten Frank M. Kulick III
James P. McQuarrie, P.E. Robert Nerenberg, Ph.D., P.E. Heather M. Phillips, P.E. Dana W. Rippon, P.E. Frank Rogalla Edward D. Schroeder, Ph.D. Dipankar Sen, Ph.D., P.E. Spencer Snowling George Sprouse, Ph.D., P.E. Christopher W. Tabor, P.E. Stephen Tarallo Ifetayo Venner, P.E. Thomas E. Wilson, Ph.D., P.E., BCEE Stefan Wuertz, Ph.D.
Under the Direction of the Municipal Design Subcommittee of the Technical Practice Committee 2010 Water Environment Federation® 601 Wythe Street Alexandria, VA 22314–1994 USA http://www.wef.org
Biofilm Reactors
.
WEF Manual of Practice No. 35 Prepared by the Biofilm Reactors Task Force of the Water Environment Federation®
., BCEE
WEF Press Water Environment Federation Alexandria, Virginia
New York Chicago San Francisco Lisbon London Madrid Mexico City Milan New Delhi San Juan Seoul Singapore Sydney Toronto
Copyright © 2011 by the Water Environment Federation. All rights reserved. Except as permitted under the United States Copyright Act of 1976, no part of this publication may be reproduced or distributed in any form or by any means, or stored in a database or retrieval system, without the prior written permission of the publisher. ISBN: 978-0-07-173708-1 MHID: 0-07-173708-1 The material in this eBook also appears in the print version of this title: ISBN: 978-0-07-173707-4, MHID: 0-07-173707-3. All trademarks are trademarks of their respective owners. Rather than put a trademark symbol after every occurrence of a trademarked name, we use names in an editorial fashion only, and to the benefit of the trademark owner, with no intention of infringement of the trademark. Where such designations appear in this book, they have been printed with initial caps. McGraw-Hill eBooks are available at special quantity discounts to use as premiums and sales promotions, or for use in corporate training programs. To contact a representative please e-mail us at
[email protected]. imPoRtaNt Notice The material presented in this publication has been prepared in accordance with generally recognized engineering principles and practices and is for general information only. This information should not be used without first securing competent advice with respect to its suitability for any general or specific application. The contents of this publication are not intended to be a standard of the Water Environment Federation® (WEF ®) and are not intended for use as a reference in purchase specifications, contracts, regulations, statutes, or any other legal document. No reference made in this publication to any specific method, product, process, or service constitutes or implies an endorsement, recommendation, or warranty thereof by WEF. WEF makes no representation or warranty of any kind, whether expressed or implied, concerning the accuracy, product, or process discussed in this publication and assumes no liability. Anyone using this information assumes all liability arising from such use, including but not limited to infringement of any patent or patents. TERMS OF USE This is a copyrighted work and The McGraw-Hill Companies, Inc. (“McGrawHill”) and its licensors reserve all rights in and to the work. Use of this work is subject to these terms. Except as permitted under the Copyright Act of 1976 and the right to store and retrieve one copy of the work, you may not decompile, disassemble, reverse engineer, reproduce, modify, create derivative works based upon, transmit, distribute, disseminate, sell, publish or sublicense the work or any part of it without McGraw-Hill’s prior consent. You may use the work for your own noncommercial and personal use; any other use of the work is strictly prohibited. Your right to use the work may be terminated if you fail to comply with these terms. THE WORK IS PROVIDED “AS IS.” McGRAW-HILL AND ITS LICENSORS MAKE NO GUARANTEES OR WARRANTIES AS TO THE ACCURACY, ADEQUACY OR COMPLETENESS OF OR RESULTS TO BE OBTAINED FROM USING THE WORK, INCLUDING ANY INFORMATION THAT CAN BE ACCESSED THROUGH THE WORK VIA HYPERLINK OR OTHERWISE, AND EXPRESSLY DISCLAIM ANY WARRANTY, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. McGraw-Hill and its licensors do not warrant or guarantee that the functions contained in the work will meet your requirements or that its operation will be uninterrupted or error free. Neither McGraw-Hill nor its licensors shall be liable to you or anyone else for any inaccuracy, error or omission, regardless of cause, in the work or for any damages resulting therefrom. McGraw-Hill has no responsibility for the content of any information accessed through the work. Under no circumstances shall McGraw-Hill and/or its licensors be liable for any indirect, incidental, special, punitive, consequential or similar damages that result from the use of or inability to use the work, even if any of them has been advised of the possibility of such damages. This limitation of liability shall apply to any claim or cause whatsoever whether such claim or cause arises in contract, tort or otherwise.
About WEF Formed in 1928, the Water Environment Federation® (WEF ®) is a not-for-profit technical and educational organization with members from varied disciplines who work toward WEF’s vision to preserve and enhance the global water environment. For information on membership, publications, and conferences, contact: Water Environment Federation® 601 Wythe Street Alexandria, VA 22314-1994 USA (703) 684-2400 http://www.wef.org
Manuals of Practice of the Water Environment Federation® The WEF Technical Practice Committee (formerly the Committee on Sewage and Industrial Wastes Practice of the Federation of Sewage and Industrial Wastes Associations) was created by the Federation Board of Control on October 11, 1941. The primary function of the Committee is to originate and produce, through appropriate subcommittees, special publications dealing with technical aspects of the broad interests of the Federation. These publications are intended to provide background information through a review of technical practices and detailed procedures that research and experience have shown to be functional and practical. Water Environment Federation Technical Practice Committee Control Group R. Fernandez, Chair J. A. Brown, Vice-Chair B. G. Jones, Past Chair A. Babatola L. W. Casson K. Conway V. D’Amato R. P. Dominak A. Ekster R. C. Johnson S. Moisio T. Page-Bottorff S. J. Passaro R. C. Porter E. P. Rothstein A. T. Sandy A. Tyagi A. K. Umble
Contents List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxv List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxiii Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxvii
Chapter 1 Introduction 1.0 Background and Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2.0 Characteristics of Fixed-Growth Processes . . . . . . . . . . . . . 2 3.0 History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3.1 Contact Beds. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3.2 Trickling Filters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3.3 Rotating Biological Contactors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3.4 Coupled Trickling Filter/Activated Sludge Process. . . . . . . . . . . . . . . . 6 3.5 Biological Filters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 3.6 Hybrid Processes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 4.0 Organization of Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 5.0 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 6.0 SUGGESTED READINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Chapter 2 Biology of Fixed-Growth Process 1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 2.0 CLASSIFICATION OF LIVING ORGANISMS . . . . . . . . . . . . . . . . . . . . . . 18 3.0 MICROORGANISMS OTHER THAN BACTERIA . . . . . . . . . . . . . . . . . . 21 3.1 Fungi. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 3.2 Algae. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 3.3 Protozoa. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 3.4 Multicellular Invertebrates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 vii
viii Contents
3.5 Viruses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 3.6 Consortia. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 4.0 CHARACTERISTICS OF BACTERIA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 4.1 Structure of the Bacterial Cell. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 4.2 Chromosome and Plasmids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 4.3 Cytoplasm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 4.4 Cell Membrane. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 4.5 Cell Wall. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 4.6 Pili. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 4.7 Flagella. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 4.8 Extracellular Polymeric Substances. . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 4.9 Chemical Composition of Cells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 4.10 Example 1—Theoretical Oxygen Demand of Bacterial Cells. . . . . . . 32 4.10.1 Solution. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 4.10.2 Comment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
5.0 B ACTERIAL METABOLISM, NUTRITION, AND RESPIRATION . . . . 33 5.1 Energy Source. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 5.2 Chemoheterotrophic Metabolism . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 5.3 Chemoautotrophic Metabolism. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 5.4 Photosynthetic Metabolism. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 5.5 Nutrient Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 5.6 Bacterial Energy Metabolism . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 5.7 Aerobic Growth and Respiration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 5.8 Anoxic Conditions and Respiration. . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 5.9 Anaerobic Respiration and Fermentative Metabolism. . . . . . . . . . . . 44 5.10 Energetics of Respiration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 5.11 Example 2—Calculation of Electrode Reduction Potentials and ∆G for Half-Reactions ��������������������������������������������������������������������48 5.12 Solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 5.13 Co-Metabolism. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Contents
6.0 BACTERIAL GROWTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 6.1 The Bacterial Growth Curve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 6.2 Growth in Mixed Cultures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 6.3 Enrichment Cultures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 6.4 Stability of Mixed Cultures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 6.5 Effects of Environmental Variables. . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 7.0 BACTERIAL GROWTH KINETICS IN BIOFILMS . . . . . . . . . . . . . . . . . 55 7.1 Rate of Bacterial Processes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 7.2 Note . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 7.3 Physical and Chemical Changes in Biofilms Resulting from Growth��������������������������������������������������������������������������������������������59 7.4 Structured Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 7.5 Temperature Effects. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 7.6 Example 3—Effect of Temperature on Organic Removal . . . . . . . . . 61 7.7 Solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 7.8 Inhibition and Toxicity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 7.9 Mass-Transfer-Rate Limitations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 8.0 KEY TRANSFORMATIONS IN BIOFILMS . . . . . . . . . . . . . . . . . . . . . . . 65 8.1 Chemoheterotrophic Processes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 8.2 Chemoautotrophic Processes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 8.3 Biology of Nitrogen Transformations. . . . . . . . . . . . . . . . . . . . . . . . . . 67 8.4 Denitrification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 8.5 Aerobic Nitrification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 8.6 Anoxic Nitrification/Denitrification. . . . . . . . . . . . . . . . . . . . . . . . . . . 69 8.7 Biological Phosphorus Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 8.8 Sulfide and Sulfur Oxidation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 8.9 Hydrogen Oxidation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 9.0 FEATURES OF MICROBIAL COMMUNITIES IN BIOFILMS . . . . . . . 72 10.0 REFERENCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
ix
x Contents
Chapter 3 Trickling Filter and Combined Trickling Filter Suspended-Growth Process Design and Operation 1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 2.0 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 2.1 Distribution System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 2.2 Biofilm Carriers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 2.3 Containment Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 2.4 Underdrain System and Ventilation. . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 2.5 Trickling Filter Pumping Stations: Influent and Recirculation. . . . . . 91 2.6 Hydraulic and Contaminant Loading. . . . . . . . . . . . . . . . . . . . . . . . . . . 92 3.0 Process Flow Sheets and Bioreactor Configuration . . 93 3.1 Standard Process Flow Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 3.2 Bioreactor Classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 3.3 Hydraulic Application: Effect on Media Wetting, Flow Distribution, and Control ��������������������������������������������������������������98 4.0 Ventilation and Air Supply Alternatives . . . . . . . . . . . . . . 100 4.1 Natural Draft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 4.2 Mechanical Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 5.0 Trickling Filter Process Models . . . . . . . . . . . . . . . . . . . . . . . . 103 5.1 National Research Council. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 5.2 Galler and Gotaas. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105 5.3 Kincannon and Stover. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 5.4 Velz. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 5.5 Schulze. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 5.6 Germain. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 5.7 Eckenfelder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 5.8 Chartered Institution of Water and Environmental Management ����������������������������������������������������������������110 5.9 Logan Trickling Filter Model. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Contents
5.10 Selecting a Trickling Filter Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 5.11 Method for Combining Trickling Filter and Suspended-Growth Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 6.0 Process Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 6.1 Combined Carbon Oxidation and Nitrification. . . . . . . . . . . . . . . . . . 115 6.2 Nitrifying Trickling Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 6.2.1 Gujer and Boller Nitrifying Trickling Filter Model. . . . . . . . . . . . . . . . . . . . . 122 6.2.2 Okey and Albertson Nitrifying Trickling Filter Model. . . . . . . . . . . . . . . . . . 124 6.2.2.1 Application of the Gujer and Boller Model. . . . . . . . . . . . . . . . . . . . . . 126 6.2.2.2 Application of the Albertson and Okey Model . . . . . . . . . . . . . . . . . . . 128
6.3 Temperature and Hydraulic Application Effects . . . . . . . . . . . . . . . . 131 7.0 Design Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 7.1 Distribution System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 7.1.1 Hydraulic Drive Rotary Distributors.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 7.1.2 Electronic or Mechanical Drive Rotary Distributors. . . . . . . . . . . . . . . . . . . . 136 7.1.3 Optimizing Rotary Distributor Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . 138
7.2 Construction of Rotary Distributors . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 7.3 Trickling Filter Media Selection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 7.3.1 Depth. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 7.3.2 Structural Integrity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
7.4 Trickling Filter Pumping Station or Dosing Siphon. . . . . . . . . . . . . . 144 7.5 Control Mechanisms for Trickling Filter Macro Fauna . . . . . . . . . . . 144 7.5.1 Operational Strategies and Facility Improvements for Macro Fauna Control . . . 145 7.5.2 Spülkraft. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 7.5.3 Flooding.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148 7.5.4 Chemical Treatment.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 7.5.5 Physical Control����������������������������������������������������������������������������������������������152
7.6 Trickling Filter Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 7.7 Combined Trickling Filter and Suspended-Growth Processes. . . . . 155 7.7.1 Activated Biofilter.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156 7.7.2 Trickling Filter/Solids Contact. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
xi
xii Contents
7.7.3 Roughing Filter/Activated Sludge.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162 7.7.4 Biofilter/Activated Sludge.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162 7.7.5 Trickling Filter/Activated Sludge. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
8.0 REFERENCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
Chapter 4 Rotating Biological Contactors 1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174 2.0 Process design considerations . . . . . . . . . . . . . . . . . . . . . . . . . 178 2.1 Media Surface Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179 2.2 pH and Nutrient Balance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 2.3 Oxygen Transfer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 2.4 Flow and Loading Variability. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 2.5 Operating Temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183 2.6 Solids Production. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183 2.7 Toxic and Inhibitory Substances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184 3.0 Rotating biological contactor design methods . . . . . 184 3.1 Monod Kinetic Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184 3.2 Second-Order Model. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186 3.3 Empirical Model. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 3.4 Manufacturers’ Design Curves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189 3.5 Comparison of Model Predictions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 3.6 Predicted Performance versus Full-Scale Data . . . . . . . . . . . . . . . . . . 191 3.7 Temperature Correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 4.0 Rotating biological contactor nitrification models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 5.0 Denitrification Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 6.0 Physical design features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198 6.1 Physical Layout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198 6.2 Tank Volume. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198 6.3 Hydraulics and Flow Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198 6.4 Media. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
Contents
6.5 Drive Systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 6.6 Covers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201 6.7 Biomass Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201 7.0 Rotating biological contactor design examples . . . 202 7.1 Secondary Treatment Design Example. . . . . . . . . . . . . . . . . . . . . . . . 202 7.2 Advanced Secondary Treatment Design Example. . . . . . . . . . . . . . 203 8.0 Problems and corrective actions . . . . . . . . . . . . . . . . . . . . . 204 8.1 Inadequate Treatment Capacity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205 8.2 Excessive First-Stage Loadings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205 8.3 Excessive Biomass Growth. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206 8.4 Loping of Air-Drive Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206 8.5 High Clarifier Effluent Suspended Solids. . . . . . . . . . . . . . . . . . . . . . 207 8.6 Corrosion of Media Supports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 9.0 Pilot-plant studies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 10.0 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208
Chapter 5 Moving-Bed Biofilm Reactors 1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212 2.0 Moving-Bed Reactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 3.0 Design Considerations for Moving-Bed Reactors . . . . . 217 3.1 Carrier Biofilms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 3.1.1 Carbonaceous Matter Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 3.1.2 High-Rate Designs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 3.1.3 Normal-Rate Designs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 3.1.4 Low-Rate Designs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 3.1.5 Nitrification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 3.1.6 Denitrification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229 3.1.6.1 Pre-Denitrification Moving-Bed Biofilm Reactors.. . . . . . . . . . . . . . . . 229 3.1.6.2 Post-Denitrification Moving-Bed Biofilm Reactors . . . . . . . . . . . . . . . 230 3.1.6.3 Combined Pre-/Post-Denitrification Moving-Bed Biofilm R eactors������������������������������������������������������������������������������������230
xiii
xiv Contents
3.2 Mixers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 3.3 Pretreatment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232 4.0 Solids Separation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 5.0 General considerations for moving-bed biofilm reactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234 5.1 Approach Velocity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234 5.2 Foaming. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234 5.3 Media Transfer and Inventory Management. . . . . . . . . . . . . . . . . . . . 234 6.0 CASE STUDIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235 6.1 Moa Point Wastewater Treatment Plant, Wellington, New Zealand��������������������������������������������������������������������������������������������235 6.2 Harrisburg Wastewater Treatment Plant, Harrisburg, Pennsylvania��������������������������������������������������������������������������������������������238 6.3 Moorhead Wastewater Treatment Facility, Moorhead, Minnesota (Adapted from Zimmerman et al., 2004)��������������������������240 6.4 Williams Monaco Wastewater Treatment Plant, Henderson, Colorado ��������������������������������������������������������������������������������������������������241 6.5 Klagsham Wastewater Treatment Plant, Malmö, Sweden (Adapted from Taljemark et al., 2004)��������������������������������������������������246 6.6 Gardemoen Wastewater Treatment Plant, Gardemoen, Norway. . . . . 250 7.0 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
Chapter 6 Hybrid Processes 1.0 OVERVIEW OF INTEGRATED FIXED-FILM ACTIVATED SLUDGE SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260 1.1 Advantages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261 1.2 Disadvantages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 2.0 Media Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 2.1 Fixed-Media Systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263 2.2 Free-Floating Media Systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264 2.2.1 Plastic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264 2.2.2 Sponge. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
Contents
3.0 History of Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265 4.0 Application of INTEGRATED FIXED-FILM ACTIVATED SLUDGE Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267 4.1 Fixed Media. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267 4.1.1 General Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267 4.1.2 Growth on Media. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268 4.1.3 Kinetics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269 4.1.4 Worm Growth. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270 4.1.5 Media Breakage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270 4.1.6 Dissolved Oxygen Level. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270 4.1.7 Mixing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271 4.1.8 Access to Diffusers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271 4.1.9 Odor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271
4.2 Free-Floating Media—Sponge Media. . . . . . . . . . . . . . . . . . . . . . . . . . 272 4.2.1 General Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272 4.2.2 Screen Clogging. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272
4.3 Control of Biomass Growth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273 4.3.1 Loss of Sponges. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273 4.3.2 Taking Tank Out-of-Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 4.3.3 Loss of Solids. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 4.3.4 Air Distribution System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 4.3.5 Plastic Media . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 4.3.5.1 General Requirements.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 4.3.5.2 Biomass Growth.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275 4.3.5.3 Media Mixing.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276 4.3.5.4 Screens. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276 4.3.5.5 Foaming. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276 4.3.5.6 Media Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276 4.3.5.7 Taking Tank Out-of-Service.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276 4.3.5.8 Worm Growth.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277 4.3.5.9 Startup.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277
xv
xvi Contents
5.0 Process Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277 5.1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277 5.2 Parameters Influencing Organics Removal in the Biofilm of Integrated Fixed-Film Activated Sludge Systems������������������������������278 5.2.1 Biofilm Flux Rates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278 5.2.2 Removals in Biofilm per Unit of Tank Volume . . . . . . . . . . . . . . . . . . . . . . . . 278
5.3 Parameters Influencing Removals in the Mixed-Liquor Suspended Solids������������������������������������������������������������������������������������281 5.4 Interaction Between the Mixed-Liquor Suspended Solids and the Biofilm����������������������������������������������������������������������������������������282 5.5 Interaction Between Heterotrophs and Nitrifiers. . . . . . . . . . . . . . . . 284 5.6 Design Tools/Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284 5.6.1 Empirical Methods. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285 5.6.1.1 Equivalent-Sludge-Age Approach. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285 5.6.1.2 Quantity (Length or Web Surface Area) of Media Approach. . . . . . . . 286 5.6.2 Rates Based on Pilot Studies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 286 5.6.3 Biofilm Rate Model. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287 5.6.3.1 Define Range of Flux Rates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287 5.6.3.2 Quantify Removal at Different Mixed-Liquor Suspended Solids Mean Cell Residence Times ������������������������������������������������������287 5.6.3.3 Select Flux Rates Based on Location Along Aerobic Zone. . . . . . . . . . 287 5.6.3.4 Calculate the Quantity of Media Required. . . . . . . . . . . . . . . . . . . . . . 288 5.6.3.5 Additional Analysis to Finalize a Design. . . . . . . . . . . . . . . . . . . . . . . 288 5.6.3.6 Application of Kinetics-Based Approach with Integrated Fixed-Film Activated Sludge Design Software������������������������������������288
6.0 Case Studies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288 6.1 Annapolis Water Reclamation Facility, Anne Arundel County, Maryland��������������������������������������������������������������������������������������������������288 6.1.1 Original Wastewater Treatment Plant. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289 6.1.2 Pilot Study (1993 to 1996). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289 6.1.3 Full-Scale Upgrade for Biological Nutrient Removal (1997 to 2000). . . . . . . 291 6.1.3.1 Pilot Study. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
Contents
6.1.3.2 During Construction (1997 to 2000) .. . . . . . . . . . . . . . . . . . . . . . . . 293 6.1.3.3 Post-Construction (2000 to 2003). . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
6.2 Westerly Wastewater Treatment Plant, Westerly, Rhode Island . . . . . 299 6.2.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299 6.2.2 Description of Original Facilities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299 6.2.3 Description of Upgrade. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299 6.2.4 Design Criteria. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302 6.2.5 Performance of the Integrated Fixed-Film Activated Sludge System. . . . . . . 302 6.2.6 Operational Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306 6.2.7 Costs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307
6.3 Broomfield Wastewater Treatment Plant, Broomfield, Colorado . . . 307 6.3.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307 6.3.2 Full-Scale Plant Results. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 308
6.4 Colony Wastewater Treatment Plant, Colony, Texas. . . . . . . . . . . . . 308 6.4.1 Introduction and Background. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 308 6.4.2 Changing Design Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316 6.4.3 Plant Construction and Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 318 6.4.4 System Flexibility. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 320 6.4.5 Redworm Predation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321
7.0 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 321
Chapter 7 Biological Filters 1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 327 2.0 Descriptions of BIOLOGICALLY ACTIVE FILTER Reactors and Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 329 2.1 Brief History of Biologically Active Filters. . . . . . . . . . . . . . . . . . . . . . 329 2.2 Downflow Biologically Active Filter with Sunken Media. . . . . . . . . 331 2.3 Upflow Biologically Active Filter with Sunken Media. . . . . . . . . . . . 334 2.4 Upflow Biologically Active Filter with Floating Media. . . . . . . . . . . 335 2.5 Moving-Bed, Continuous Backwash Filters. . . . . . . . . . . . . . . . . . . . . 337 2.6 Non-Backwashing, Open-Structure Media Filters . . . . . . . . . . . . . . . 339
xvii
xviii Contents
3.0 Media for Use in BIOLOGICALLY ACTIVE FILTERS . . . . . . . . . . . 341 3.1 Mineral Media. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 341 3.2 Random Plastic Media. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343 3.3 Modular Plastic Media. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 345 4.0 Backwashing and Air-Scouring . . . . . . . . . . . . . . . . . . . . . . . . . 345 5.0 BIOLOGICALLY ACTIVE FILTER Process Design . . . . . . . . . . . . . 349 5.1 Process Design for Secondary Treatment. . . . . . . . . . . . . . . . . . . . . . . 351 5.1.1 Volumetric Biochemical Oxygen Demand Loading. . . . . . . . . . . . . . . . . . . . . 351 5.1.2 Hydraulic Loading. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351 5.1.3 Backwashing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351 5.1.4 Design Example: Design of a Submerged, Upflow Biological Aerated Filter System for Secondary Treatment (No Nitrification) ��������������353 5.1.5 Solution. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 353
5.2 Process Design for Nitrification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 355 5.2.1 Influence of Hydraulic Filtration Rates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 355 5.2.2 Effect of Process Air Velocity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 357 5.2.3 Dependence on Loading Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359 5.2.4 Temperature Effects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 360 5.2.5 Design Example: Design of a Submerged, Upflow Biological Aerated Filter System for Nitrification Following Secondary Treatment��������������������360 5.2.6 Solution. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 361
5.3 Process Design for Combined Nitrification and Denitrification. . . . 362 5.4 Process Design for Tertiary Denitrification . . . . . . . . . . . . . . . . . . . . . 365 5.4.1 Volumetric Mass Loading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 365 5.4.2 Half-Order Kinetic Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 367 5.4.3 Hydraulic Loading. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 368 5.4.4 Solids Removal and Sludge Production. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 368 5.4.5 Supplemental Carbon Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 369 5.4.6 Tertiary Denitrification Typical Operations Issues and Corrective Actions�������������������������������������������������������������������������������������������� 370 5.4.6.1 Excess Backwashing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 370 5.4.6.2 Gas (Nitrogen) Accumulation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 371
Contents
5.4.6.3 Solids Breakthrough. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 371 5.4.6.4 Nitrate/Nitrite Breakthrough ��������������������������������������������������������������371 5.4.6.5 Carbon Breakthrough. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372 5.4.6.6 Phosphorus Management.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372 5.4.6.7 Operation During Peak Flow Events . . . . . . . . . . . . . . . . . . . . . . . . . . 372
5.5 Phosphorus Removal Considerations for Biologically Active Filter Processes����������������������������������������������������������������������������������������373 6.0 Design Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374 6.1 Preliminary and Primary Treatment. . . . . . . . . . . . . . . . . . . . . . . . . . . 374 6.2 Backwash Handling Facilities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374 6.3 Biologically Active Filter Process Aeration . . . . . . . . . . . . . . . . . . . . . 375 6.3.1 Oxygen-Transfer Efficiency. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 375 6.3.2 Process Air Distribution Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377 6.3.3 Process Air Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377
6.4 Supplemental Carbon Feed Requirements. . . . . . . . . . . . . . . . . . . . . . 378 7.0 Biologically active filter Case Studies . . . . . . . . . . . . . . . . 379 7.1 Chemically Enhanced Primary Treatment Followed by Two-Stage Biologically Active Filter for Total Nitrogen Removal: VEAS Wastewater Treatment Plant, Oslo, Norway ��������379 7.2 Chemically Enhanced Primary Treatment Followed by Three-Stage Biologically Active Filter for Total Nitrogen Removal: Siene Centre Wastewater Treatment Plant, Colombes, France��������������������������������381 7.3 Total Nitrogen Removal in a Single-Stage Biologically Active Filter: Frederikshavn Wastewater Treatment Plant, Denmark��������384 7.4 Nitrification and Denitrification: West Warwick, Rhode Island��������������������������������������������������������������������������������������������387 7.5 Post-Denitrification Sand Filters: Havelock, North Carolina. . . . . . 389 8.0 REFERENCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 391
Chapter 8 New and Emerging Fixed-Film Technologies 1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 401 2.0 BIOFILM REACTORS WITH SUSPENDED CARRIERS OR GRANULES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 402
xix
xx Contents
2.1 Biofilm Airlift Suspension Reactor . . . . . . . . . . . . . . . . . . . . . . . . . . . 402 2.2 Upflow Anaerobic Sludge Blanket . . . . . . . . . . . . . . . . . . . . . . . . . . . 404 2.3 Expanded Granular Sludge Blanket . . . . . . . . . . . . . . . . . . . . . . . . . . 404 2.4 Internal Circulation Reactor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 404 3.0 ANAMMOX BIOFILM REACTORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 405 4.0 MEMBRANE BIOFILM REACTORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 406 5.0 REFERENCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 408
Chapter 9 Clarification 1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 414 2.0 Solids-Separation Choices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 416 3.0 Design Approach . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 417 3.1 Types of Settling Regimes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 418 3.1.1 Type I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 419 3.1.2 Type II. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 419 3.1.3 Type III. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 419 3.1.4 Type IV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 419
3.2 Special Considerations for Nutrient Removal Sludges. . . . . . . . . . . 3.3 Clarifier Enhancements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4 Wastewater Flocculation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5 Flocculation Criteria. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6 Clarifier Design Details. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
419 420 422 424 429
3.6.1 Influent Column. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 431 3.6.2 Energy-Dissipating Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 431 3.6.3 Feed Well (Flocculating Type). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 433 3.6.4 Side Water Depth, Clear Water Zone, and Overflow Rate . . . . . . . . . . . . . . . 435 3.6.5 Floor Slope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 438 3.6.6 Effluent Weir and Launder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 440 3.6.7 Sludge Collectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 443 3.6.8 Sludge Hopper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 445
3.7 Rectangular versus Circular Clarifiers . . . . . . . . . . . . . . . . . . . . . . . . . 445
Contents
3.8 Design Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 446 3.9 Clarifier Following Moving-Bed Biofilm Reactor, Trickling Filter, Rotating Biological Contactor, and Biotower��������������������������448 3.9.1 Secondary (Integrated Fixed-Film Activated Sludge) Clarifiers. . . . . . . . . . . 451 3.9.2 Sludge Hopper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 454 3.9.3 Process Performance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 455
3.10 Other Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 458 3.10.1 Modeling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 458 3.10.2 Interaction with Other Facilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 458 3.10.3 International Practices. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 458
4.0 REFERENCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 459
Chapter 10 Effluent Filtration 1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 463 2.0 Process performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 465 3.0 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 469
Chapter 11 Development and Application of Models for Integrated Fixed-Film Activated Sludge, Moving-Bed Biofilm Reactors, Biological Aerated Filters, and Trickling Filters 1.0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 473 2.0 MODELING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 478 2.1 Numerical Approach Using Semi-Empirical Equations for Biofilm (Steady-State and Dynamic Simulation)��������������������������������478 2.1.1 Ammonium-Nitrogen Uptake Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 480 2.1.1.1 Ammonium-Nitrogen Uptake Rate by Nitrifiers in Biofilm. . . . . . . . . 480 2.1.1.2 Biofilm Nitrification Rates from Pilot Studies . . . . . . . . . . . . . . . . . . . 482 2.1.1.3 Ammonium-Nitrogen Uptake Rate by Nitrifiers in Mixed-Liquor Volatile Suspended Solids ��������������������������������������������485 2.1.1.4 Mass Balance for Ammonium-Nitrogen in Each Reactor. . . . . . . . . . . 490 2.1.2 Chemical Oxygen Demand Removal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 494
xxi
xxii Contents
2.1.3 Biomass Production . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 499 2.1.3.1 Mixed-Liquor Volatile Suspended Solids . . . . . . . . . . . . . . . . . . . . . . . 500 2.1.3.2 Biofilm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 501 2.1.4 Fraction of Nitrifiers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 502 2.1.5 Denitrification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 503 2.1.6 Oxygen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 504
2.2 Numerical Approach to Solve One- and Two-Dimensional BiofilmDiffusion Models (Steady-State and Dynamic Simulation)��������������504 2.2.1 Ammonium-Nitrogen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 506 2.2.2 Linkage to Equations 11.1 to 11.42 Presented Earlier. . . . . . . . . . . . . . . . . . . 508 2.2.3 Chemical Oxygen Demand, Biomass (Volatile and Total Suspended Solids), Dissolved Oxygen, and NOx-N ��������������������������������������������������������510 2.2.4 Biofilm Thickness, Growth, and Fraction Nitrifiers. . . . . . . . . . . . . . . . . . . . . 510
3.0 MODEL APPLICATIONS TO FULL-SCALE FACILITIES . . . . . . . . . . . 512 3.1 Integrated Fixed-Film Activated Sludge Plant Description and Modeling ������������������������������������������������������������������������������������������513 3.1.1 Integrated Fixed-Film Activated Sludge Plant Description. . . . . . . . . . . . . . 514 3.1.2 Integrated Fixed-Film Activated Sludge Plant Operation. . . . . . . . . . . . . . . . 515 3.1.2.1 Data from December 2006. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 515 3.1.2.2 Flow and Recycle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 515 3.1.2.2.1 Primary Effluent.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 515 3.1.2.2.2 Aerobic Cells. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 518 3.1.2.2.3 Secondary/Plant Effluent. . . . . . . . . . . . . . . . . . . . . . . . . . . . 518 3.1.2.2.4 Discussion of the Data.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 518 3.1.3 Modeling Integrated Fixed-Film Activated Sludge in Aquifas . . . . . . . . . . . . 518 3.1.3.1 Results from Aquifas. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 519 3.1.3.2 Key Inputs to Aquifas Biofilm One-Dimensional Model . . . . . . . . . . . 526 3.1.3.3 Discussion of Aquifas Model and Accuracy of Results. . . . . . . . . . . . . 526 3.1.4 Modeling in BioWin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 527 3.1.4.1 Framework. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 527 3.1.4.2 Results from BioWin.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 531 3.1.4.3 Discussion of Results from BioWin. . . . . . . . . . . . . . . . . . . . . . . . . . . . 531
Contents
3.2 Moving-Bed Biofilm Reactor Plant Description and Modeling. . . . . 534 3.2.1 Moving-Bed Biofilm Reactor Modeling with GPS-X. . . . . . . . . . . . . . . . . . . . 537 3.2.1.1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 537 3.2.1.2 Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 542 3.2.2 Moving-Bed Biofilm Reactor Modeling with Aquifas. . . . . . . . . . . . . . . . . . . 542 3.2.3 Moving-Bed Biofilm Reactor Modeling—General Comments. . . . . . . . . . . . . 543 3.2.4 Integrated Fixed-Film Activated Sludge and Moving-Bed Biofilm Reactor Modeling—General Observations������������������������������������������������������552
4.0 REFERENCEs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 553
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 559
xxiii
This page intentionally left blank
List of Figures Figure 2.1 2.2 2.3 2.4 2.5 2.6
2.7 2.8
2.9
2.10
2.11 3.1 3.2
Page
Coenocytic cell structure typical of many fungi, in which cell contents, or cytoplasm, is multinucleate and continuous throughout the organism. . . . . . . . . . . . . 22 Schematic representation of the bacterial cell.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Examples of organic compounds that are toxic and/or difficult to biooxidize.. . . . . . 37 Repeating glucose units of starch and glycogen connected by α-glycosidic bonds and cellulose connected by β-glycosidic bonds. . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Schematic of reactions through which pyrite [FeS2(s)] is oxidized in mine drainage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Bacterial growth curve for a batch system in which nutrients initially are not limiting. As growth begins, the increase in cell number (or mass) is dependent only on the number (or mass) of cells present, and the system behaves in a first-order autocatalytic manner.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Relationships between organic removal, cell mass production, and OUR.. . . . . . . . . . 58 Structured models of metabolism include reactions or steps in the metabolic process that can be identified or separated: (a) the rate of metabolism is separated from the rate of organic removal from the liquid and (b) a somewhat more complex storage mechanism is shown, which could be used to account for several observed rates of growth and oxygen uptake.. . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Effect of temperature on organic removal rate and microbial growth in example 3. Initial BODU and suspended solids concentrations were 400 mg/L and 30 mg/L, respectively. The initial conditions provide for near-exponential growth because K << Co.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 Effect of inhibitant concentration on specific removal rate for two conditions: (a) substrate inhibition by a metabolizable inhibitant, represented by eq 2.22, and (b) a nonmetabolizable inhibitant, such as a heavy metal, represented by eq 2.23.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Steps in the removal and breakdown of an organic particle in a biofilm.. . . . . . . . . . . 66 Typical trickling filter components and cross-section.. . . . . . . . . . . . . . . . . . . . . . . . . . . 85 Hydraulically driven rotary distributors use variable frequency drive controlled gates that either open or close distributor orifices, which adjust with varying pumped flowrates to maintain a constant preset rotational speed, and electrically driven rotary distributor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
xxv
xxvi List of Figures
3.3
3.4
3.5
3.6 3.7
3.8
3.9 3.10 3.11 3.12 3.13 3.14 3.15 3.16
3.17 3.18
3.19 3.20 3.21 3.22
Adjustable plastic stanchions and FRP grating on the concrete floor of a bolted steel containment structure, and an HDPE mat used to support random synthetic media.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 Typical flow diagrams for the trickling filter process: (a) and (b) single-stage trickling filter process, (c) two-stage trickling filter process, and (d) two-stage trickling filter process with intermediate clarification. . . . . . . . . . . . . . . . . . . . . . . . . . . 94 Typical flow diagrams for trickling filter-suspended growth processes: (a) activated biofilter, (b) trickling filter/solids contact or trickling filter/activated sludge, (c) activated biofilter/solids contact or activated biofilter/activated sludge, and (d) trickling filter and activated sludge.. . . . . . . . . . . . 95 Three-dimensional representation of liquid flow distribution in cross-flow media, both (a) with and (b) without biofilm.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 (a) Trickling filter underdrain and media supports with air distribution piping throughout the underdrain, and (b) typical low-pressure fan applied to provide process air.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 Effect of SRT in a suspended-growth reactor and nitrification efficiency in an upstream trickling filter on effluent ammonia-nitrogen concentration in a combined TF/SG reactor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 Nitrification efficiency versus organic loading in rock-media trickling filters. . . . . . 116 Nitrification efficiency as a function of filtered, or soluble, BOD5 in the effluent of a vertical-flow media trickling filter at Stockton, California.. . . . . . . . . . . 117 Nitrification efficiency versus organic loading in trickling filters.. . . . . . . . . . . . . . . . 118 Nitrification efficiency versus organic loading in trickling filters.. . . . . . . . . . . . . . . . 119 Effect of bulk liquid TSS concentration on nitrification in a pilot-scale NTF.. . . . . . . 122 Transition NH3-N concentrations as function of temperature.. . . . . . . . . . . . . . . . . . . 125 Actual and predicted effluent from an NTF. Predicted effluent was calculated using the modified Gujer and Boller (1986) model.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131 (a) Typical hydraulically driven rotary distributor with reverse-thrusting jets and electric drive, and (b) modern hydraulically driven rotary distributor with variable-frequency controlled gates that close or open orifices (therefore, the flowrate contributes to reverse thrust).. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 (a) Modern hydraulically driven rotary distributor, (b) gate controller, (c) orifices, and (d) full-length arm and distributor.. . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 (a) “Pouch” snail typically found in trickling filters treating m unicipal wastewater, and (b) a modular plastic media sheet with biofilm and snail-grazing pathways.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 Snail shells covering fine-bubble diffusers in suspended-growth reactors that are located in (a) Pueblo, Colorado; and (b) Garland, Texas.. . . . . . . . . . . . . . . . . . . . . 146 Biofilm and filter fly control with low-frequency dosing.. . . . . . . . . . . . . . . . . . . . . . . 148 Nitrifying trickling filter operating modes for high-concentration undissociated aqueous ammonia dosing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 Nitrification rate and biomass accumulation in pilot-scale NTFs after startup.. . . . . 155
List of Figures
3.23 4.1 4.2 4.3
4.4
4.5 4.6 4.7 4.8
4.9 4.10 5.1 5.2 5.3
5.4 5.5 5.6
5.7 5.8
Three modes of TF/SC process operation.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160 General representation of RBC process.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 RBC process general flow arrangements.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177 Clark RBC predictive model, Monod kinetics, BOD5 removal: (1) values are total BOD5; (2) 50% sBOD5 assumed; (3) >13°C (>55°F) temperature; (4) three stages, with 50% of media area in the first stage; and (5) standard-density media. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186 Opatken RBC predictive model, second-order kinetics, BOD5 removal: (1) values are total BOD5; (2) >13°C (>55°F) temperature; (3) 50% sBOD5 assumed; (4) three stages, with 50% of media area in the first stage; and (5) standard-density media. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 Benjes RBC predictive model, BOD5 removal: (1) values are total BOD5; (2) >13°C (>55°F) temperature; and (3) standard-density media.. . . . . . . . . . . . . . . . . 188 Manufacturers’ RBC design basis, BOD5 removal: (1) values are total BOD5; (2) >13°C (>55°F) temperature; and (3) 50% sBOD5 assumed. . . . . . . . . . . . . . . . . . . . 189 Equipment manufacturers’ predictions versus full-scale plant data, BOD5 removal.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 Benjes RBC model predictions versus full-scale plant data, BOD5 removal: (1) values are total BOD5; (2) k = 0.30; (3) >13°C (>55°F) temperature; and (3) standard-density media. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 Benjes RBC predictive model, effect of k rate on predicted performance (standard-density media assumed).. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 Manufacturers’ design basis, nitrification of domestic wastewater. . . . . . . . . . . . . . . 196 Vertical mounted flat-panel sieves with air sparge system and horizontal sieves located over aeration grid.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 (a) Aeration grid and distribution piping, and (b) stainless diffuser with 4-mm aeration-holes along underside.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 Representative carriers removed from each of four moving-bed reactors in series showing the variation in biofilm color (specialization and biofilm concentration (active biofilm) dependent on the operating condition and treatment function of each reactor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 (a) COD removal efficiency at high loading conditions, and (b) poor settling character of biofilm slough under high loading rates. . . . . . . . . . . . . . . . . . . . . . . . . . . 221 Soluble BOD removal rate as a function of total BOD loading in roughing MBBR application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 (a) Effect of BOD loading and dissolved oxygen on nitrification rates at 15°C (adapted from Hem et al. [1994]), and (b) difference in nitrification rate between multiple MBBRs in series.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223 Influence of dissolved oxygen at low ammonia concentrations. . . . . . . . . . . . . . . . . . 225 (a) Seasonal biomass concentration and temperature in tertiary nitrifying MBBR, and (b) nitrification activity grouped by temperature condition as a function of dissolved oxygen level.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228
xxvii
xxviii List of Figures
5.9 5.10
5.11 5.12 5.13 5.14 5.15 5.16 5.17 5.18 5.19 5.20 5.21 5.22 5.23 5.24 5.25 5.26 5.27 6.1 6.2
6.3 6.4 6.5 6.6 6.7 6.8 6.9 6.10 6.11 6.12 6.13
Denitrification rate as a function of temperature with different external carbon types.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 (a) ABS 123K mixers installed toward the surface of the reactor oriented with a 30-degree negative inclination to “push” the media down into the depths of the reactor, and (b) post-denitrification MBBR reactor in operation at the Sjölunda WWTP (Malmö, Sweden).. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232 Simplified liquid treatment schematic of Moa Point WWTP (New Zealand). . . . . . . 236 BOD profile results at Moa Point WWTP (New Zealand).. . . . . . . . . . . . . . . . . . . . . . . 237 (a) Test periods 1, 2, and 3, and (b) test periods 4 through 9. . . . . . . . . . . . . . . . . . . . . 238 Ammonia removal rate as function of loading rate in a tertiary MBBR.. . . . . . . . . . . 239 Simplified liquid treatment schematic of Moorhead WWTF (Minnesota).. . . . . . . . . 240 Ammonia profile results across nitrifying MBBR at the Moorhead WWTF (Minnesota).. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 Simplified liquid treatment schematic of Williams Monaco WWTP (Colorado).. . . . 242 Two MBBR trains with four reactors each: anoxic and aerated.. . . . . . . . . . . . . . . . . . 243 BOD profile results across MBBRs at Williams Monaco WWTP (Colorado) (2004 to 2007). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 Settled effluent TSS at Williams Monaco WWTP (Colorado) (2004 to 2007). . . . . . . . 245 Simplified liquid treatment schematic of Klagsham WWTP (Sweden).. . . . . . . . . . . . 247 Effluent BOD7 results at Klagsham WWTP (Sweden).. . . . . . . . . . . . . . . . . . . . . . . . . . 249 Effluent total nitrogen results at Klagsham WWTP (Sweden).. . . . . . . . . . . . . . . . . . . 249 Effluent total phosphorus results at Klagsham WWTP (Sweden).. . . . . . . . . . . . . . . . 249 Simplified liquid treatment schematic of Gardemoen WWTP (Norway).. . . . . . . . . . 251 Ammonia profile results across MBBRs at Gardemoen WWTP (Norway) (2001).. . . 252 Nitrogen profile results across MBBRs at Gardemoen WWTP (Norway) (2001).. . . . 252 IFAS process versus conventional activated sludge process. . . . . . . . . . . . . . . . . . . . . 260 Effect of biofilm thickness on locations of growth and surface area of biofilm: (a) magnitude of difference in biofilm surface area for “thin” and “thick” biofilms on the same carrier particle of moving-bed or IFAS system, and (b) magnitude of difference in biofilm surface area for “thin” and “thick” biofilms on the same carrier particle of moving-bed or IFAS system. . . . . . . . . . . . . . 279 Typical layout of plastic-carrier-media IFAS systems.. . . . . . . . . . . . . . . . . . . . . . . . . . 282 Typical layout of sponge-media IFAS system.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283 Typical layout of cord or web fixed-bed-media IFAS systems.. . . . . . . . . . . . . . . . . . . 283 Pilot study configuration.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 Schematic of BNR upgrade to IFAS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292 Process configuration for BNR upgrade. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292 Westerly, Rhode Island WWTF IFAS system flow diagram.. . . . . . . . . . . . . . . . . . . . . 300 Westerly, Rhode Island, WWTF IFAS system reactor train plan.. . . . . . . . . . . . . . . . . 301 Full-scale flow diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309 Monthly operating data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314 Polyester fabric media.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316
List of Figures
6.14 6.15 6.16 6.17 6.18 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 7.9 7.10 7.11 7.12 7.13 7.14
7.15 7.16 7.17 7.18 7.19 7.20 8.1 9.1 9.2
9.3 9.4 9.5
Existing and proposed aeration basin configuration.. . . . . . . . . . . . . . . . . . . . . . . . . . . 317 Proposed process flow diagram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317 Installation of 10 IFAS media modules in existing basin.. . . . . . . . . . . . . . . . . . . . . . . . 319 Effluent cBOD concentration after train B startup.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 319 Effluent ammonia concentration (7-day average).. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .320 BAF process flow diagrams.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328 BioCarbone® biological filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332 Downflow denitrification filter.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333 Biofor® upflow biological filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334 Biostyr® process arrangement for nitrification and denitrification. . . . . . . . . . . . . . . . 336 Schematic of moving-bed denitrification filter.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338 Schematic of non-backwashing, open-structure media filter.. . . . . . . . . . . . . . . . . . . . 339 Mineral media upflow SAF with block underdrain.. . . . . . . . . . . . . . . . . . . . . . . . . . . . 340 Carrier diameter versus media specific surface area.. . . . . . . . . . . . . . . . . . . . . . . . . . . 344 Relation between total solids of backwash liquor and time for different backwash airflow rates.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347 Relationship between total solids of backwash liquor and time for d ifferent backwash water flowrates. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 347 Nitrification rate for differently pretreated raw wastewaters as a function of C:N ratio. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 356 Maximum nitrification versus long-term average loading.. . . . . . . . . . . . . . . . . . . . . . 359 BAF configurations for combined nitrification and denitrification: (a) pre-denitrification/nitrification and optional post-denitrification, and (b) pre-denitrification/nitrification in one reactor.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363 Nitrification with flocculated raw wastewater.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363 Denitrification filter design curves using EBDT with additional data points. . . . . . . 369 VEAS WWTP schematic.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 380 Seine Centre WWTP liquid treatment schematic.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 382 Frederikshavn Central WWTP liquid treatment schematic. . . . . . . . . . . . . . . . . . . . . . 386 Nitrification and denitrification BAF reactors at West Warwick, Rhode Island.. . . . 388 Reactor configurations: (a) UASB, (b) EGSB, (c) BAS, and (d) internal circulation. . . . . 403 BOD5 content of effluent versus TSS and trickling filter loading.. . . . . . . . . . . . . . . . . 415 (a) Suspended solids concentration and turbidity data collected throughout the study with a linear relationship function and 95% suspended solids concentration prediction interval estimate; (b) turbidity/time data collected from the Camp Creek plant on August 13, 1990, with batch flocculation curve fit; (c) turbidity/time data collected at the Utoy Creek plant on July 19, 1990, with batch flocculation curve fit; and (d) turbidity/time data collected at the Coneross plant on May 30, 1991, with batch flocculation curve fit.. . . . . . . . . . . . . . . 425 Effect of coarse-bubble aeration rate on effluent solids.. . . . . . . . . . . . . . . . . . . . . . . . . 426 Flocculation procedures, test number 1.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 427 Flocculation procedures, test number 2a.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 428
xxix
xxx List of Figures
9.6 9.7 9.8 9.9 9.10 9.11 9.12 9.13 9.14 9.15 10.1 10.2 10.3 10.4
EDI and hydraulic flocculating feed well. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 432 General arrangement of the improved clarifier inlet structure. . . . . . . . . . . . . . . . . . . 433 Dense sludge blanket profile: average and peak flows.. . . . . . . . . . . . . . . . . . . . . . . . . 435 Clarifier detention: efficiency versus CWD.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 436 Recommendations for primary clarifier floor configuration.. . . . . . . . . . . . . . . . . . . . . 439 Clarifier improvement with Stamford baffle.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 441 McKinney (Lincoln)/Stamford baffle arrangements.. . . . . . . . . . . . . . . . . . . . . . . . . . . 443 General arrangement of sludge hopper.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 446 General arrangement of improved wastewater clarifier.. . . . . . . . . . . . . . . . . . . . . . . . 447 EDI primary clarifier.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450 Cloth filters.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 465 Traveling-bridge filter.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 465 Compressible media filters.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 466 Performance data for six different types of granular-medium filters tested on the same activated sludge effluent at a filtration rate of 2.7 L/m2 s (4 gpm/sq ft).. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 467 11.1 Plant configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 474 11.2 Schematic of IFAS and MBBR system with 10 cells (reactors) in series operating in enhanced nutrient removal configuration.. . . . . . . . . . . . . . . . . . . . . . . . . 475 11.3 Modeling biofilm in (a) trickling filter, (b) MBBRs, and (c) BAF.. . . . . . . . . . . . . . . . . 476 11.4 Nitrification rates for biofilm in IFAS and MBBR systems: (a) biodegradable COD limiting nitrifiers in biofilm, ammonium-nitrogen is not limiting, liquid temperature = 12°C, soluble biodegradable COD >10 mg/L, NH4-N > 3 mg/L, measured at a dissolved oxygen concentration of 8 to 9 mg/L; (b) liquid temperature = 12°C, soluble biodegradable COD < 10 mg/L, NH4-N < 5 mg/L, measured at dissolved oxygen concentration of 8 to 9 mg/L.. . . . . . . . . . . . . . . . . . . . 484 11.5 COD uptake rates for biofilm in IFAS and MBBR systems: liquid temperature = 12°C, measured at a dissolved oxygen concentration of 8 to 9 mg/L.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 496 11.6 Layout of Broomfield WWTP, Colorado.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 514 11.7 Aquifas output: The figures in the left column are from the semi-empirical model; the figures in the right column are from the biofilm one-dimensional model. The diffusion model can offer a higher degree of precision in its ability to predict day-to-day variations in a dynamic simulation, but takes substantially longer to run. Both models are able to predict the diurnal and 31-day average. . . . . . . . . . . 522 11.8 Substrate profiles for COD, NH4-N, and NO3N. The left column is from the semi-empirical model; the right column is from the biofilm one-dimensional model.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 523 11.9 COD uptake, NH4-N uptake, and denitrification in the biofilm and MLVSS. . . . . . . 524 11.10 Substrate profiles (dissolved oxygen, NH4-N, NOx-N, SCODbio, and percent VSS) inside the biofilm in aerobic cells 1 and 2.. . . . . . . . . . . . . . . . . . . . . . . . . 525
List of Figures
11.11 11.12 11.13 11.14 11.15 11.16 11.17 11.18
11.19 11.20 11.21 11.22 11.23 11.24
Typical raw influent COD fractions in BioWin. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 528 Screen shot of IFAS model in BioWin.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 531 BioWin IFAS calibration results for effluent ammonia and nitrate.. . . . . . . . . . . . . . . 532 BioWin IFAS calibration results for MLSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 532 BioWin IFAS calibration results for effluent BOD and TSS. . . . . . . . . . . . . . . . . . . . . . 533 Schematic of one of two MBBR trains at the South Adams plant, Adams County, Colorado���������������������������������������������������������������������������������������������������������������������������������� 534 Layout of MBBR as modeled in GPS-X������������������������������������������������������������������������������ 543 Comparison of MBBR effluent NH3-N and NOx-N from GPS-X model, with actual data. The NH3-N represents ammonium-nitrogen + ammonia-nitrogen; at pH ~7, >99% is as ammonium-nitrogen. ���������������������������������������������������������������������� 546 Comparison of MBBR secondary effluent BOD5 and TSS model results from GPSX model with actual data �������������������������������������������������������������������������������������������������������� 546 Comparison of MBBR effluent MLSS (before settling in secondary clarifier) from GPSX model with actual data.������������������������������������������������������������������������������������ 547 Layout of South Adams MBBR as modeled in AquaNET (Windows.NET) version of Aquifas.������������������������������������������������������������������������������������������������������������������������������ 547 Comparison of MBBR effluent NH3-N and NOx-N from Aquifas model with actual data������������������������������������������������������������������������������������������������������������������������������ 550 Comparison of MBBR secondary effluent BOD5 from Aquifas model with actual data������������������������������������������������������������������������������������������������������������������������������������������ 551 Comparison of MBBR effluent MLSS (before settling in secondary clarifier) from Aquifas model with actual data�������������������������������������������������������������������������������� 551
xxxi
This page intentionally left blank
List of Tables Table 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 3.1 3.2 3.3 3.4 3.5 4.1 4.2 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10 5.11 5.12 5.13 5.14 5.15
Page
Subdivisions of organisms and principal groups found in biological treatment systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Common human diseases caused by viruses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Typical composition of Escherichia coli.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Typical elemental composition of bacterial cells.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 Classification of living organisms by carbon and energy sources.. . . . . . . . . . . . . . . . . 34 Bacterial metabolism and respiration.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Standard reduction potentials at 25°C for selected environmentally important redox couples.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 BODU and suspended solids concentrations for the three temperature values.. . . . . . 63 Properties of some trickling filter media.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 Trickling filter classification.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 Operating and flushing dosing rates for distributors.*. . . . . . . . . . . . . . . . . . . . . . . . . . 100 Reported zero-order nitrification rates for vertical- and cross-flow media. . . . . . . . . 121 Design criteria for selected combined TF/SG processes.. . . . . . . . . . . . . . . . . . . . . . . . 157 Comparison of organic loadings for models.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 Media surface adjustment factors.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 Plastic biofilm carriers.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215 General summary of treatment schemes offered by MBBRs.. . . . . . . . . . . . . . . . . . . . .219 Typical BOD design loading criteria.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 Average results from normal-rate MBBRs with chemical phosphorus removal.. . . . 222 Examples of reported O2:NH4-N.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226 Examples of reported temperature-dependency coefficients.. . . . . . . . . . . . . . . . . . . . 227 Examples of typical pre-denitrification rates observed with municipal wastewater.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229 Screening examples at MBBR installations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 Solids separation examples at MBBR installations.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 MBBR/solids contact process at Moa Point WWTP (New Zealand).. . . . . . . . . . . . . . 236 Tertiary MBBR process at Moorhead WWTF (Minnesota).. . . . . . . . . . . . . . . . . . . . . . 240 Multistage MBBR process at Williams Monaco WWTP (Colorado). . . . . . . . . . . . . . . 243 Post-denitrification MBBR process at Klagsham WWTP (Sweden).. . . . . . . . . . . . . . . 247 Multistage MBBRs at Gardemoen WWTP (Norway).. . . . . . . . . . . . . . . . . . . . . . . . . . . 251 Summary of annual performance showing that the process meets performance requirements.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
xxxiii
xxxiv List of Tables
6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 6.9 6.10 6.11 6.12 6.13 6.14 7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 7.9 7.10 7.11 7.12 7.13 7.14 7.15 9.1 9.2 9.3 9.4 9.5 9.6 9.7
Summary of media characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280 Biofilm SSA of various types of media.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281 Design criteria, original Annapolis WRF.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 Design criteria, BNR upgrade.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293 Operating MLSS MCRTs, HRTs, media, and average performance for IFAS. . . . . . . 293 Performance data.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294 Summary of discharge permit limits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303 Design criteria for the Westerly LINPOR-CN system.. . . . . . . . . . . . . . . . . . . . . . . . . . 303 Summary of operating data.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304 Effluent requirements.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307 Specific design criteria for the upgraded plant.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309 Influent data.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310 Effluent data.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312 Colony, Texas, 2004 historical influent loadings and effluent discharge. . . . . . . . . . . 315 Commercially available BAF reactor systems and media.. . . . . . . . . . . . . . . . . . . . . . . 342 Summary of baf backwashing requirements.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348 Typical BAF loading rates for secondary treatment.. . . . . . . . . . . . . . . . . . . . . . . . . . . . 352 Effect of water velocity on nitrification rate for three types of biofilters. . . . . . . . . . . 356 Influence of grain size and shape on performance from testing in Oslo, Norway. . . 357 Typical BAF loading rates for nitrification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 358 Typical biologically active filter loading rates (BAF) for pre-denitrification.. . . . . . . 365 Typical biologically active filters (BAF) loading rates for post-denitrification. . . . . . 366 Performance results for two-stage BAF in Oslo, Norway.. . . . . . . . . . . . . . . . . . . . . . . 381 Year 2000 average performance for three-stage BAF system at Seine Center WWTP.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383 Year 2000 average performance for first-stage BAF system at Seine Center WWTP.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384 Year 2000 average performance for second-stage BAF system at Seine Center WWTP.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384 Year 2000 average performance for third stage BAF system at Seine C enter WWTP.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 385 Year 1998 average performance for the two-stage BAF at F rederikshavn Central WWTP.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 387 Havelock WWTP comparison of effluent BOD and total nitrogen average and variation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 390 Clarification characteristics of trickling filter systems in municipal WWTPs. . . . . . . 421 Energy gradient (G) values as a function of aeration type. . . . . . . . . . . . . . . . . . . . . . . 427 Clarifier design features/interactions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 430 Example minimum floor slopes versus diameter for clarifiers with scrapers.. . . . . . 440 Results of full-scale study of launder positioning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 442 Design basis for primary and secondary clarifiers.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 447 Review of secondary clarifier operating conditions.. . . . . . . . . . . . . . . . . . . . . . . . . . . . 452
List of Tables
9.8 9.9 10.1 11.1 11.2 11.3 11.4 11.5 11.6 11.7 11.8 11.9 11.10 11.11 11.12 11.13 11.14 11.15 11.16
Effluent quality of single-stage trickling filter nitrification plants.. . . . . . . . . . . . . . . . 456 Clarified/filtered effluent quality of Ohio nitrifying trickling filter plants.. . . . . . . . 457 Full-scale filtration of settled trickling filter effluent.. . . . . . . . . . . . . . . . . . . . . . . . . . . 468 Biofilm specific areas and modeling trickling filter, TF/AS, MBBR, and BAFs within models.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 478 Typical biofilm yields. Yields are generated by running a biofilm one-dimensional model or from measurements in pilot studies.. . . . . . . . . . . . . . . . . 480 Values of coefficients measured in pilot studies and the default values for the semi-empirical model.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 486 Matrix showing kinetic coefficients for MLVSS in semi-empirical and biofilm models.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 493 Semi-empirical modeling of the biofilm—equations for semi-empirical computation of biofilm flux.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 495 Actual plant data used for IFAS process model.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 516 Comparison of 31-day average from dynamic simulation against plant data Aquifas semi-empirical and biofilm one-dimensional models.. . . . . . . . . . . . . . . . . . . 520 Measured and computed values of biofilm growth (Aquifas biofilm one-dimensional model).. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 525 Summary of the BioWin influent fractions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 529 Steady-state BioWin calibration results for a full-scale IFAS facility.. . . . . . . . . . . . . . 530 SA-T1: MBBR influent data and cell data for dissolved oxygen, January 2007.. . . . . 535 SA-T2: MBBR effluent data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 538 SA-T3: Principal GPS-X biofilm parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 540 SA-T4: Summary of GPS-X influent fractions (Mantis and ASM2d).. . . . . . . . . . . . . . 540 South Adams County (Colorado) steady-state results for January 2007 with GPS-X.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 544 South Adams County—steady state results for January 2007 with Aquifas. . . . . . . . 548
xxxv
This page intentionally left blank
Preface The purpose of this Manual of Practice (MOP) is to provide a detailed understanding of all aspects of wastewater treatment using fixed-film processes. By way of background, an overview of the historical development of fixed-film treatment systems is provided. The microbiology of attached growth biofilms is presented as background to better understand the design and operation of the various fixed-film technologies. The following types of pure fixed-film and hybrid treatment systems are discussed in detail: • Trickling filters, • Rotating biological contactors, • Moving-bed biofilm reactors, • Integrated fixed-film activated sludge, and • Biological filters. Both aerated and anoxic applications of the biological filter systems are included. The chapter on trickling filters discusses combined fixed-film and suspended-growth processes. There is a chapter dedicated to new and emerging fixed-film treatment processes, including such processes as upflow anaerobic sludge blanket reactors and anammox biofilm reactors. Factors that affect the design of the various processes, appropriate design criteria and procedures, modelling techniques, equipment available, and construction features are discussed. Operational issues associated with each type of process are presented, including potential problems and corrective actions. Case studies are included to illustrate the application of these technologies. Finally, there is a detailed discussion of modeling techniques as applied to fixed-film and hybrid processes. The chapter discusses the use of several commercially available models.
xxxvii
xxxviii
Preface
The overall objective of this book is to provide the reader with a complete understanding of the types of pure and hybrid fixed-growth treatment processes available and an understanding of their design, performance, and operational issues. This Manual of Practice was produced under the direction of Rhodes R. Copithorn, P.E., BCEE, Chair. The principal authors of this Manual of Practice are as follows: Chapter 1 Chapter 2 Chapter 3 Chapter 4 Chapter 5 Chapter 6 Chapter 7 Chapter 8 Chapter 9 Chapter 10 Chapter 11
Rhodes R. Copithorn, P.E., BCEE, Chair Stefan Wuertz, Ph.D. Edward D. Schroeder, Ph.D. Joshua P. Boltz, Ph.D., P.E. Joshua P. Boltz, Ph.D., P.E. James P. McQuarrie, P.E. Rhodes R. Copithorn, P.E., BCEE, Chair Dipankar Sen, Ph.D., P.E. Christine deBarbadillo, P.E. Joseph A. Husband, P.E., BCEE Frank Rogalla Christopher W. Tabor, P.E. Stephen Tarallo Robert Nerenberg, Ph.D., P.E. Thomas E. Wilson, Ph.D., P.E., BCEE Joseph A. Husband, P.E., BCEE Dipankar Sen, Ph.D., P.E. Heather Phillips, P.E.
Authors’ and reviewers’ efforts were supported by the following organizations: AECOM, Alexandria, Virginia Aqualia, Madrid, Spain Black & Veatch Corporation, Gaithersburg, Maryland, and Kansas City, Missouri Brentwood Industries, Reading, Pennsylvania CDM, Newport News, Virginia, and Portland, Oregon CH2M Hill, Philadelphia, Pennsylvania; Tampa, Florida; Redding, California Earth Tech, Alexandria, Virginia Entex Technology, Inc., Chapel Hill, North Carolina
Preface
GHD, Bowie, Maryland Greeley and Hansen, LLC, Wilmington, Delaware Hydromantis, Inc., Hamilton, Ontario, Canada Malcolm Pirnie, Inc., Columbus, Ohio, and White Plains, New York Regional Municipality of Waterloo, Ontario, Canada Thomas E. Wilson Environmental Engineers LLC, Barrington, Illinois University of California, Davis, California University of Notre Dame, Notre Dame, Indiana Woodard & Curran, Cheshire, Connecticut, and Dedham, Massachusetts
xxxix
This page intentionally left blank
Biofilm Reactors
This page intentionally left blank
Chapter 1
Introduction 1.0 Background and Purpose
3.4 Coupled Trickling Filter/ Activated-Sludge Process 6 3.5 Biological Filters 7 3.6 Hybrid Processes 7
1
2.0 Characteristics of FixedGrowth Processes 2 3.0 History 3.1 Contact Beds 3.2 Trickling Filters 3.3 Rotating Biological Contactors
3 4 4
4.0 Organization of Manual
10
5.0 References
11
5
6.0 SUGGESTED READINGS
14
1.0 Background and Purpose This manual of practice is an update of the special publication titled Aerobic FixedGrowth Reactors, previously published by the Water Environment Federation® (Alexandria, Virginia) (WEF) in the year 2000. A number of changes in our understanding of biofilm processes and the technology and regulations that drive the wastewater treatment industry prompted this decision to rewrite the manual. Techniques developed in the field of molecular biology have expanded our understanding of biofilm kinetics and their microbial ecology. Regulations are imposing increasingly more stringent limits on the concentration of pollutants that may be discharged, including, most importantly, nutrients. The imposition of nitrogen and phosphorus limits has dramatically changed the design and operation of wastewater treatment facilities. These changes have brought about advances in the technology applied to 1
2
Biofilm Reactors
wastewater treatment, including many significant changes to the type of fixed-film treatment processes that are available today. The change in the title of this manual from Aerobic Fixed-Growth Reactors to Biofilm Reactors acknowledges some of these advances. The manual now incorporates both aerobic and anoxic fixed-film treatment processes that are applied for biological carbon and nitrogen removal.
2.0 Characteristics of Fixed-Growth Processes Although the basic metabolic processes that biological systems use to remove carbon and nutrients in wastewater treatment plants (WWTPs) are the same for fixed-film and suspended-growth systems, there are some inherent differences that provide several advantages and some challenges for the application of fixed-film processes. It is difficult to generalize, because each specific application has its own set of advantages and disadvantages, as will become apparent in the discussion of the various fixed-growth technologies discussed in this manual. However, a general summary of the differences would be useful at this point. Suspended-growth systems are comprised of biological flocs, but, theoretically, all of the dissolved substrate is available to all of the cells. With fixed-growth systems, the substrates must diffuse through the biofilm layers to become available; thus, the transport of substrate from the bulk liquid through the stagnant boundary layer and into the biofilm through the process of diffusion becomes another limiting factor. End products of the metabolic reactions must diffuse in the reverse direction. Thus, a cross-section through a fully developed biofilm will exhibit varying environmental and kinetic characteristics. A single biofilm may have aerobic, anoxic, and anaerobic processes occurring, and the substrate that becomes limiting will change through the depth of the biofilm. Thus, fixed-film processes are quite complex to model. Some advantages generally associated with fixed-film processes include the following: • Reduced operating and energy costs, • Smaller reactor volume, • Minimized need for settling capacity, and • Operational simplicity.
Introduction
Disadvantages are more specific to each technology, and they will be discussed in subsequent chapters. However, some general concerns associated with fixed-film processes include the following: • Potential clogging of the media system as a result of inadequate screening; • Excessive growth, which could plug the media system or cause free-floating media to sink; and • Inadequate mixing or short-circuiting, resulting in inefficient use of the media.
3.0 History Biological wastewater treatment technology has advanced tremendously since its early roots as a primitive science in the late 1800s. Much of the impetus was provided by increasingly crowded urban centers and the outbreak of typhoid resulting from a lack of understanding of public health issues. As the science developed, there was an early understanding that aeration of the wastewater was beneficial. An excellent presentation of the origins and development of fixed-film treatment processes has been provided by Alleman and Peters (1982). Initial experiments with this practice yielded nominal results, most likely because of a lack of understanding regarding the need for an active biomass. Aeration of fixed-film processes provided better results because of the presence of an established biomass. This was understood more fully later, as Gilbert J. Fowler of the University of Manchester, England, and his associates, Edward Ardern and William T. Lockett, in the first few decades of the 1900s, experimented with various processes, which led to our understanding of activated sludge (Cooper, 2001). Fixed-film processes continued to evolve as experimenters substituted wooden lathes in place of coarse rock, in an effort to increase the available surface area. Much of this work was advanced in the United Kingdom at the Manchester Sewage Works and at the Lawrence Experiment Station in Lawrence, Massachusetts (now known as the Senator William X. Wall Experiment Station). Biological filters originally were developed by the Lawrence Experiment Station in Massachusetts (Mills, 1890), using gravel for the biological media. These results proved that the process was not merely mechanical filtration, but also involved removal of pollutants by biological growth on the media. The results showed a correlation between the media volume and the volume of wastewater that could be treated.
3
4
Biofilm Reactors
From this beginning, the process evolved to be the dominant secondary wastewater treatment process in the United States and elsewhere by the 1950s. The introduction of synthetic media in the 1950s resulted in extending the use of fixed-growth concepts. Continued research led to the development of high-rate systems, such as biological aerated filters, moving-bed biofilm reactors, and various hybrid systems that combine the advantages of both suspended-growth and fixed-film processes.
3.1 Contact Beds The 1890s studies at the Lawrence Experiment Station in Massachusetts were viewed with interest in the United Kingdom. Corbett (1902) developed a trickling filter design that was the forerunner of today’s trickling filter systems. There was provision for distributing the influent across the surface of the gravel bed and ventilation of the underdrain. Independently, Crimp (1890) and Dibdin (1903) conducted studies that led to the development and use of a process known as a contact bed. Crimp and Dibdin constructed a basin, filled it with slag media, provided a means of flooding the basin, and then slowly drained it after approximately 1 hour of contact. The tank then was allowed to stand empty for 4 to 6 hours, which permitted the organics on the surface of the media to be oxidized. To prevent plugging of the slate media, the wastewater was screened or chemically precipitated before application. As a result, 75% removal of the oxidizable organic matter in the wastewater at a hydraulic loading rate of 1.2 m3/m2·d was obtained. The process evolved further by adding stages. However, clogging remained a continuing problem that was not resolved easily. The demise of the contact bed was initiated when the Royal Commission on Sewage Disposal report (1908) was published, which showed that a trickling filter could process twice as much wastewater per unit of volume as a two-stage contact bed.
3.2 Trickling Filters The emergence of the trickling filter was aided by the development of an effective means of distributing the flow to the filter media. Caink (1897) and Candy (1898) advanced Mills’ Lawrence Experiment Station concept into a rotating arm distribution system driven by water jets. Around the same time, a reciprocating distributor was developed for the rectangular filters, and mechanical drives (engine and electrically driven) were in use by 1904 (Stanbridge, 1972). The trickling filter process
Introduction
evolved further, and many different connotations were used to describe the process configurations. Following the initial evaluation by Dow Chemical Company (Midland, Michigan) from 1954 to 1955 (Bryan, 1955; Dow Chemical Company, 1955), the combined efforts of the Mead Corporation (Dayton, Ohio), Fluor Corporation (Irving, Texas), and Dow Chemical Company resulted in the development and application of both random and bundle synthetic media in the late 1950s. The history of the developmental stage of plastic media is described in reviews by Bryan (1982) and Peters and Alleman (1982). Different media configurations, producing different surface areas, continue to evolve today.
3.3 Rotating Biological Contactors Rotating biological contactors (RBCs) were an outgrowth of trickling filters and were influenced by the desire to reduce power consumption for wastewater treatment. Steels (1974) credits the first RBC concept to have been around 1900. A wooden cylinder with slatted walls was filled with brushwood and slowly rotated while approximately 50% submerged. Extensive testing of the RBC process was conducted in Germany. In 1900, Weigand patented a rotary cylinder made of wooden slats (Alleman and Peters, 1982). In the 1950s, researchers first used asbestos sheets, and, by the early 1960s, expanded polystyrene media came into use. The use of this lightweight material allowed the shafts holding the media to be lengthened. This resulted in a major growth of the RBC in the 1960s and 1970s, with more than 700 plants put into operation in Europe and the United States. This growth subsequently was stymied by several problems that developed, including performance of less than design expectations, excess biomass accumulations, shaft breakage, loping of disks (caused by unbalanced biomass weight), and undesirable biological growths. Most of the early developmental problems have been resolved, and there are many systems operating successfully, but the acceptance of RBCs as an effective treatment process has not returned to its former level among design engineers and owners. A submerged RBC, or submerged biological contactor (SBC), appeared in the 1980s, in which the discs are 70 to 90% submerged, and the shaft is driven by air. The intent was to decrease the loading on the shafts, improve biomass control, and provide an opportunity to retrofit existing activated sludge basins. The SBCs have been piloted for denitrification in an anoxic reactor. However, SBCs have seen only limited application.
5
6
Biofilm Reactors
3.4 Coupled Trickling Filter/Activated-Sludge Process The use of coupled process designs likely precedes the 1950s, although definitive reports are lacking. The development of plastic media led to the use of trickling filters for highly loaded (roughing) modes of operation. These units were found to be suited particularly for strong municipal and industrial wastewater. Bryan and Moeller (1960) reported that the initial coupled process installation was designed to improve the quality of an activated sludge (AS) effluent during upset conditions. Soon after, the roughing trickling filter (RTF) found a better process location, which was before the activated sludge process. Here, the RTF smoothed the loading and stabilized the overall process. It also was used to protect activated sludge systems against toxic and shock loads from industrial contributors. Gehm and Gellman (1965) demonstrated that the coupled RTF/AS process could provide for control of bulking organisms and thus enhance the overall performance of WWTPs. The reduction of the sludge volume index (Gehm and Gellman, 1965) often was cited as the reason for using a trickling filter before an activated sludge system. Lower energy costs and the ability to handle shock loads also were cited as advantages of the coupled process. Many WWTPs receiving food, beverage, and other highcarbohydrate wastewater found it beneficial to provide partial treatment of the wastewater with trickling filters before the activated sludge process, to enhance the overall treatment performance. In the early 1970s, a modified trickling filter concept using wood slat media was marketed. This concept was called the activated biofilter (ABF) process. The first reference to this concept was reported by Egan and Sandlin (1960), where the settled sludge from a plastic media effluent was recycled over the tower. Bryan (1962) reported on the design of the Saginaw Bay and Cities Service facilities in Saginaw, Michigan, where provision was made to recirculate the return activated sludge through a media filter. In this process, the sloughed trickling filter biomass was recirculated at a high rate through the filter. The filter used an open media, and wood stacks were the most common media. This trickling filter concept was later coupled with a short-term (15 to 30 minutes) activated sludge system (ABF/AS) (Slechta and Owen, 1974), at Corvallis, Oregon, and found wide acceptance for treating municipal and industrial wastewater. Research in Corvallis, Oregon, during the late 1970s led to the development of the trickling filter/solids contact process in 1979 (Norris et al., 1982). This process uses a trickling filter sized for the removal of the majority of the soluble organic matter
Introduction
followed by an aerated solids contact channel or basin and a secondary clarifier with recycle of return activated sludge to the aerated solids channel. The primary purpose of the aerated solids contact channel is to flocculate suspended solids contained in trickling filter effluent for removal in the secondary clarifier.
3.5 Biological Filters The basic concept of the biological filter is to provide a high specific surface area for the growth of biomass in a compact volume. The biological filter provides for both the removal of substrates biologically and the retention of solids, which are removed periodically through a backwash cycle. The basic technology has been applied to aerobic, anoxic, and anaerobic processes. Biological aerated filters (BAFs) were developed in the 1980s in Europe and have found extensive application since then for carbon and nitrogen removal. Since 1982, over 500 installations have been built using a variety of technologies (Stephenson et al., 2004). A wide variety of configurations and media systems have been developed, but, generally, the advantages that have come to be recognized for this type of technology include the following: • Relatively small space requirement, because they are typically high-rate systems; • Ability to treat dilute wastewaters; • No concern for sludge settleability; and • Relatively easy to contain potential odors. The technologies may be categorized according to whether they are upflow or downflow processes; packed bed or fluidized bed; and aerobic, anoxic, or anaerobic.
3.6 Hybrid Processes The use of fixed-film media in aerated reactors is an old concept. In recent years, the concept has been referred to as integrated fixed-film activated sludge (IFAS) and has been used increasingly as a means of improving the treatment capacity and nutrient removal capabilities of existing activated sludge facilities. Before the 1940s, the Hays and Griffith processes (Wilford and Conlon, 1957) used baffles, cement asbestos, wood, or other construction materials in the aeration tank to enhance performance. The Hays and Griffith processes were improved over
7
8
Biofilm Reactors
the original process (Hays, 1931), in which submerged rock filters were force-aerated. These processes were called submerged contact aeration processes. Approximately 60 Hays contact plants were constructed for United States Army camps between 1940 and 1945 (Packham, 1988). Wood, asbestos, and plastic sheeting were fixed in the aeration basin to provide a surface for bacterial growth. The plant treatment trains consisted of primary clarification followed by two equally sized aeration basins with intermediate and final clarification. Sludge return was not practiced. Asbestos sheets were suspended vertically in the aeration basins, such that they extended from 10 cm below the liquid surface to just above the horizontal grid of aeration pipes. The asbestos sheets were spaced 3.8 cm apart throughout the length of the aeration tanks and permitted a serpentine pathway for floating material. The aerators provided oxygen transfer and mixing between the asbestos sheets, and treatment was affected by the attached fixed-film growth on the sheets. Typical combined hydraulic retention times for the two aeration basins ranged from 1.7 to 3.0 hours. The National Research Council Report (1946) developed design criteria for the contact aeration process simultaneously with the development of design criteria for activated sludge and trickling filter processes. The contact aeration process eventually failed because of the additional cost of aeration and because it produced a lower quality effluent compared with the activated sludge process. The process essentially ceased to be used in the 1960s. Steels (1974) reported on previous attempts in the 1920s to improve plant operations by retaining various types of small particulates in the aeration basins. These particulates included grit, brushwood, wood, and cork and were effective in treating strong wastewater. The Hays and Griffith processes resurfaced in a number of variant forms, including a similar concept (Hamoda and Abd-El-Bary, 1987) referred to as an activated submerged fixed-growth bioreactor. The use of submerged RBCs in aeration basins is another form of this concept. The basic concept of these systems, as currently applied, is to increase the amount of biomass available for treatment per unit volume. By retaining the biomass on a fixed-film media within the suspended-growth reactor, treatment performance can be enhanced without increasing the solids loading on the secondary clarifiers. The IFAS systems, in their various forms, combine the apparent advantages of both fixedfilm and suspended-growth biomass systems. Another major effort to use fixed-film media in aeration tanks originated in Japan during the 1960s. Kato and Sekikawa (1967) developed a process that they called fixed
Introduction
activated sludge and applied primarily to the treatment of industrial wastes. This process vertically suspended an open plastic matrix in an aerated reactor and typically was operated without a return sludge. More than 60 such installations were in place in Japan during the 1960s. Both fixed and free-floating types of media systems have been developed. A rope-type media, which is installed on racks placed in the activated sludge basins, originally was developed in Japan for the purpose of achieving greater levels of carbonaceous biochemical oxygen demand removal within the volume of an existing activated sludge basin (Iwai et al., 1990). The product then was applied in Germany to upgrade treatment plants for nitrification and subsequently in North America for both purposes. The majority of applications have been in aerobic basins or in basins that alternate between aerobic and anoxic conditions. Pilot testing of the rope-type media began in the United States in the early 1990s, followed by full-scale installations (Randall and Sen, 1996). Several different types of rope media have been developed and are available commercially. Free-floating types of systems use the sponge of plastic media. Processes using sponge-type media originally were developed in Europe in the late 1970s, and two basic systems emerged. One system, the Captor process (Atkinson et al., 1979), was developed by Simon-Hartley through work completed at the University of Manchester in the United Kingdom. The concept was commercialized by Simon-Hartley in conjunction with several universities, Severn Trent Water Authority (Birmingham, United Kingdom), and the Water Research Center in Swindon, Wiltshire, United Kingdom. A second sponge-type system was developed by the LindeAG Corporation in the mid-1970s (Hegemann, 1984) and was introduced commercially in Europe and North America as the Linpor System by the Lotepro Corporation (Mount Kisco, New York) (Morper and Wildmoser, 1990; Reimann, 1990). A plastic media system using small cylindrical biofilm carrier elements originally was developed by Kaldnes Miljoteknologi in Norway (Odegaard and Rusten, 1990; Odegaard et al., 1994). There currently are several manufacturers of this type of media system. The free-floating media systems have been applied in both IFAS and movingbed biofilm reactor (MBBR) configurations. The MBBR process differs from IFAS in that there is no return activated sludge; thus, the MBBR is a pure fixed-film process and not a hybrid. The plastic media by Kaldnes Mitjoteknologi originally was developed as an MBBR process and was patented (AnoxKaldnes MBBR) (Odegaard, 2006).
9
10
Biofilm Reactors
4.0 Organization of Manual A brief description of the organization of this manual and the material contained in each chapter is presented in this section. Chapter 2 presents the microbiology of wastewater treatment as applied to biofilms and is intended to provide a foundation for understanding the discussion of kinetics presented in the individual technology chapters and in the final chapter on modeling. Trickling filter processes and RBC processes are discussed in Chapters 3 and 4, respectively. Moving-bed biofilm reactors are discussed in Chapter 5. In each case, the process and mechanical design considerations and the operational issues are presented. Various design approaches are presented, including both empirical and kinetic-based models specific to the technology. Application of the technologies to carbon removal and nutrient removal are presented, and case studies are included. The focus of Chapter 6, Hybrid Processes, is on IFAS processes. The various types of media incorporated to IFAS systems are discussed with design considerations relevant to each type of media. Case studies are presented to illustrate their application. Chapter 7, Biological Filters, presents the design, construction, and operational issues associated with aerobic and anoxic biological filters in their various configurations, including downflow and upflow BAFs with sunken media, upflow with floating media, open-structure media filters, and continuous backwash filters. The application of biological filters for carbon removal, nitrification, and denitrification is discussed. New and emerging technologies that show promise in the laboratory or through small pilot-scale studies, but that are not yet commercially available, are discussed in Chapter 8. Clarification, as it relates to meeting advanced levels of treatment following fixed-film systems, is discussed in the following two chapters. Chapter 9 discusses gravity settling and membrane separation. Chapter 10 discusses effluent filtration technologies. Finally, a comprehensive discussion of modeling concepts is presented in Chapter 11. Each technology chapter presents modeling techniques specific to that process, but this chapter covers the kinetics in general, modeling techniques, and application of models to various types of pure fixed-film and hybrid systems.
Introduction
5.0 References Alleman, J.; Peters, R (1982) The History of Fixed Film Wastewater Treatment Systems. Proceedings of the International Conference of Fixed Film Biological Processes, Kings Island, Ohio. http://web.deu.edu.tr/atiksu/ana52/biofilm4. pdf (accessed March 2010). Atkinson, B.; Black, G. M.; Lewis, P. J. S.; Pinches, A. (1979) Biological Particles of Given Size, Shape and Density for Use in Biological Reactors. Biotechnol. Bioeng., 21 (2), 193–200. Bryan, E. H. (1982) Development of Synthetic Media for Biological Treatment of Municipal and Industrial Wastewater. Paper presented at the 1st International Conference on Fixed-Film Biological. Processes, Vol. 1, Kings Island, Ohio; Sponsored by University of Pittsburg, U.S. Army Corps of Engineers, U.S. Environmental Protection Agency, and U.S. National Science Foundation), 89. Bryan, E. H. (1955) Molded Polystyrene Media for Trickling Filters. Proceedings of the 10th Purdue Industrial Waste Conference, West Lafayette, Indiana, May 9–11; Purdue University: West Lafayette, Indiana, 164. Bryan, E. H. (1962) Two-Stage Biological Treatment: Industrial Experience. Proceedings of the 11th South Municipal Industrial Waste Conference; North Carolina State University, North Carolina. Bryan, E. H.; Moeller, D. H. (1960) Aerobic Biological Oxidation Using Dowpac. Proceedings of the Conference on Biological Waste Treatment; Manhattan College: Riverdale, New York. Caink, T. (1897) Specifications of Inventions. Br. Patent 19153. Candy, F. P. (1898) Specifications of Inventions. Br. Patent 2749. Cooper, P. F. (2001) Historical Aspects of Wastewater Treatment, Decentralized Sanitation and Reuse: Concepts, Systems and Implementation, Chapter 2; International Water Association Publishing: London, United Kingdom. Corbett, J. (1902) Some Sewage Purification Treatment Experiments. J. Sanit. Inst., 23, 601–602. Crimp, S. (1890) The Construction of Works for the Prevention of Pollution by Sewage of Rivers and Estuaries; Charles Griffin & Company: London, United Kingdom.
11
12
Biofilm Reactors
Dibdin, W. J. (1903) The Purification of Sewage and Water, 3rd ed.; The Sanitary Publishing Company: London, United Kingdom. Dow Chemical Company (1955) Dowpac™ FN-90 and Dow HCS™. Plastics Technical Services., Dow Chemical Company: Midland, Michigan. Egan, J. T.; Sandlin, M. (1960) The Evaluation of Plastic Trickling Filter Media. Proceedings of the 15th Purdue Industrial Waste Conference, West Lafayette, Indiana; Purdue University: West Lafayette, Indiana, 107–-115. Gehm, H. W.; Gellman, I. (1965) Practice, Research and Development in Biological Oxidation of Pump and Paper Effluents. J. Water Pollut. Control Fed., 57, 1392–1398. Hamoda, M. F.; Abd-El-Bary, M. F. (1987) Operating Characteristics of the Aerated Submerged Fixed-Film (ASFF) Bioreactor. Water Res., 21, 939–947. Hays, C. C. (1931) Sewage Treatment Process. U.S. Patent 1,991,896. Hegemann, W. (1984) A Combination of the Activated Sludge Process with FixedFilm Bio-Mass to Increase the Capacity of Wastewater Treatment Plants. Water Sci. Technol., 16, 119–130. Iwai, S.; Oshino, Y.; Tsukada, T. (1990) Design Operation of Small Wastewater Treatment Plants by the Microbial Film Process. Water Sci. Technol., 22, 139–144. Kato, K.; Sekikawa, Y. (1967) FAS (Fixed Activated Sludge) Process for Industrial Waste Treatment. Proceedings of the 22nd Purdue Industrial Waste Conference, West Lafayette, Indiana; Purdue University: West Lafayette, Indiana, 926–949. Mills, H. F. (1890) Purification of Sewage and Water. Special report to the Massachusetts State Board of Health: Boston, Massachusetts, 25. Morper, M.; Wildmoser, A. (1990) Improvement of Existing Wastewater Treatment Plant Efficiencies Without Enlargement of Tankage by Application of the Linpor Process—Case Studies. Water Sci. Technol., 37, 207–215. Norris, D. P.; Parker, D. S.; Daniels, M. L.; Owens, E. L. (1982) High Quality Trickling Filter Effluent Without Tertiary Treatment. J. Water Pollut. Control Fed., 54, 1087–1098. Odegaard, H. (2006) Innovations in Wastewater Treatment: the Moving Bed Biofilm Process. Water Sci. Technol., 53, 17–33.
Introduction
Odegaard, H.; Rusten, B. (1990) Upgrading of Small Municipal Wastewater Treatment Plants with Heavy Dairy Loadings by Introduction of Aerated Submerged Biofilters. Water Sci. Technol., 22 (7/8), 191–198. Odegaard, H.; Rusten, B.; Westrum, T. (1994) A New Moving Bed Biofilm Reactor—Application and Results. Proceedings of the 2nd International Specialized Conference on Biofilm Reactors, Paris, France, Sep 29–Oct 1; International Association on Water Quality: London, United Kingdom, 221–229. Packham, R. F. (1988) Biological Filtration. Manuals of British Practice in Water ollution. Control, Institute of Water Pollution Control: London, United Kingdom. Peters, R. W.; Alleman, J. E. (1982) The History of Wastewater Treatment Systems. Paper presented at 1st International Conerence on Fixed-Film Biological Processes, Vol. 1, Kings Island, Ohio (sponsored by University of Pittsburg, U.S. Army Corps of Engineers, U.S. Environmental Protection Agency, and U.S. National Science Foundation), 60. Randall, C.; Sen, D. (1996) Full-Scale Evaluation of an Integrated Fixed-Film Activated Sludge (IFAS) Process for Enhanced Nitrogen Removal. Water Sci. Technol., 33 (12), 155–162. Reimann, H. (1990) The Linpor Process for Nitrification and Denitrification. Water Sci. Technol., 22, 297–298. Royal Commission on Sewage Disposal (1908) Fourth Report. Royal Commission on Sewage Disposal: London, United Kingdom. Slechta, A. E.; Owen, W. F. (1974) ABF Short-Term Aeration-Pilot Plant Results, Corvallis, OR. Technical Bulletin, Neptune, Microfloc, Inc.: Corvallis, Oregon. Stanbridge, H. H. (1972) The Introduction of Rotating and Traveling Distributors for Biological Filters. Water Pollut. Control, 44, 573. Steels, I. H. (1974) Design Basis for the Rotating Disc Process. Effluent Water Treat. J., 14 (9), 434–445. Stephenson, T.; Cornel, P.; Rogalla, F. (2004) Biological Aerated Filters (BAF) in Europe: 21 Years of Full Scale Experience. Proceedings of the 77th Annual Water Environment Federation Technical Exposition and Conference, New Orleans, Louisiana, Oct 2–6; Water Environment Federation: Alexandria, Virginia. Wilford, J.; Conlon, T. P. (1957) Contact Aeration Sewage Treatment Plants in New Jersey. Sew. Ind. Wastes, 29, 845–855.
13
14
Biofilm Reactors
6.0 SUGGESTED READINGS Sen, D.; Randall, C. W. (1996) Mathematical Model for a Multi-CSTR Integrated Fixed Film Activated Sludge (IFAS) System. Proceedings of the 69th Annual Water Environment Federation Technical Exposition and Conference, Dallas, Texas, Oct 5–9; Water Environment Federation: Alexandria, Virginia. Stensel, H. D.; Brenner, R.; Lee, K.; Melcer, H.; Rakness, K. (1988) Biological Aerated Filter Evaluation. J. Environ, Eng., 114 (6), 1352–1358.
Chapter 2
Biology of Fixed-Growth Process 1.0 INTRODUCTION
17
4.7 Flagella 4.8 Extracellular Polymeric Substances 4.9 Chemical Composition of Cells 4.10 Example 1—Theoretical Oxygen Demand of Bacterial Cells 4.10.1 Solution 4.10.2 Comment
2.0 CLASSIFICATION OF LIVING ORGANISMS 18 3.0 MICROORGANISMS OTHER THAN BACTERIA 21 3.1 Fungi 22 3.2 Algae 22 3.3 Protozoa 23 3.4 Multicellular Invertebrates 23 3.5 Viruses 24 3.6 Consortia 26 4.0 CHARACTERISTICS OF BACTERIA 4.1 Structure of the Bacterial Cell 4.2 Chromosome and Plasmids 4.3 Cytoplasm 4.4 Cell Membrane 4.5 Cell Wall 4.6 Pili
5.0 BACTERIAL METABOLISM, NUTRITION, AND RESPIRATION 5.1 Energy Source 5.2 Chemoheterotrophic Metabolism 5.3 Chemoautotrophic Metabolism 5.4 Photosynthetic Metabolism 5.5 Nutrient Requirements 5.6 Bacterial Energy Metabolism
26 26 28 30 30 30 31
31 31 32
32 32 33
33 36 36 38 39 40 41
(continued) 15
16
Biofilm Reactors
5.7 Aerobic Growth and Respiration 5.8 Anoxic Conditions and Respiration 5.9 Anaerobic Respiration and Fermentative Metabolism 5.10 Energetics of Respiration 5.11 Example 2—Calculation of Electrode Reduction Potentials and ∆G for Half-Reactions 5.12 Solution 5.13 Co-Metabolism 6.0 BACTERIAL GROWTH 6.1 The Bacterial Growth Curve 6.2 Growth in Mixed Cultures 6.3 Enrichment Cultures 6.4 Stability of Mixed Cultures
42 43
44 46
48 48 50 51 51 53 53 54
6.5 Effects of Environmental Variables 54 7.0 BACTERIAL GROWTH KINETICS IN BIOFILMS 7.1 Rate of Bacterial Processes 7.2 Note 7.3 Physical and Chemical Changes in Biofilms Resulting from Growth
55 56 56
59
7.4 Structured Models 7.5 Temperature Effects 7.6 Example 3—Effect of Temperature on Organic Removal
59 60
7.7 Solution 7.8 Inhibition and Toxicity 7.9 Mass-Transfer-Rate Limitations
61
61
63 64
8.0 KEY TRANSFORMATIONS IN BIOFILMS 65 8.1 Chemoheterotrophic Processes 66 8.2 Chemoautotrophic Processes 67 8.3 Biology of Nitrogen Transformations 67 8.4 Denitrification 67 8.5 Aerobic Nitrification 68 8.6 Anoxic Nitrification/ Denitrification 69 8.7 Biological Phosphorus Removal 70 8.8 Sulfide and Sulfur Oxidation 71 8.9 Hydrogen Oxidation 71 9.0 FEATURES OF MICROBIAL COMMUNITIES IN BIOFILMS 72 10.0 REFERENCES
74
Biology of Fixed-Growth Process
1.0 INTRODUCTION The purpose of this chapter is to provide a general introduction to the biology of fixedgrowth processes used in water and wastewater treatment. Although the fundamental principles of biological processes are the same for all process configurations, the constraints of fixed-growth processes result in particular characteristics of microbial communities and advantages and disadvantages relative to alternative systems. In fixed-growth processes, fluid containing necessary nutrients passes over the microorganisms growing in a biofilm on a support surface. Nutrients diffuse into the biofilm and are metabolized by the immobilized microorganisms. A significant result is that microbial populations can function well, even when fluid-phase nutrient concentrations are extremely low (Schroeder, 2002; Schroeder et al., 2000). Correspondingly, at high fluid-phase nutrient concentrations, oxygen transfer may become limiting, and anoxic zones may develop within the biofilm. The most basic considerations in microbial treatment process design and operation are that microorganisms use contaminants in water or wastewater as sources of carbon and energy for growth, as nutrients required to sustain growth, or as electron acceptors in the respiratory process. In all cases, microorganisms remove contaminants from the dissolved state; that is, particulate material must first be dissolved and then metabolized. Engineering of microbial systems requires consideration of the requirements for microbial growth and determination of the conditions necessary to carry out the desired biochemical reactions. Particular constraints encountered in biological wastewater treatment include the necessity to remove a wide range of organic and inorganic materials, consistent production of finished waters having extraordinarily low organic and suspended solids concentrations, and the presence of organic materials that are highly toxic to most forms of life. The environmental requirements for biological growth generally are inconsistent with the production of potable waters. If biological treatment is a step in the production of potable waters, a number of abiotic treatment steps must be incorporated downstream. In a sense, most rivers form minimally controlled treatment links between wastewater and potable water treatment systems. Treated wastewater discharged to rivers is diluted and contaminants are further stabilized before extraction and treatment of water for use by municipalities.
17
18
Biofilm Reactors
2.0 CLASSIFICATION OF LIVING ORGANISMS Living organisms currently are classified into three general domains—Eucarya, Bacteria, and Archaea (see Table 2.1). Viruses—nonliving obligate infectious particles—are significant factors in microbial processes and also are discussed in this chapter. Two types of cell organization exist—eukaryotic and prokaryotic. Plants; animals; and the algae, protozoa, and fungi have eukaryotic cells, while members of the Bacteria and Archaea domains have the structurally simpler prokaryotic cell type. Viruses do not have a cellular structure, being composed of one or two strands of genetic material (deoxyribonucleic acid or ribonucleic acid) and a protein coat or
Table 2.1 Subdivisions of organisms and principal groups found in biological treatment systems. Domain or group
Cell structure Properties
Constituent groups
Eukaryotes
Eukaryotic
Nematodes, Plants (seed plants, rotifers ferns, mosses), algae, fungi Animals (invertebrates, vertebrates)
Multicellular, extensive differentiation of cells and tissues
Groups commonly found in biological treatment
Algae, fungi, protozoa Unicellular, mycelial or filamentous: little or no differentiation of cell type
All groups
Bacteria
Prokaryotic
Cell chemistry similar to Eukaryotes
Most bacteria
Most Gram-positive genera, some Gram-negative genera
Archaea
Prokaryotic
Distinctive cell chemistry
Methanogens, halophiles, thermoacidophiles
Methanogens
Viruses
None
Non-living, obligate parasites composed of nucleic acid strand(s) and protein coat or capsid
Biology of Fixed-Growth Process
capsid. Eukaryotes are divided into two general groups—multicellular organisms, in which cells have specific functions, and unicellular organisms, in which all cells carry out the same range of functions. Multicellular organisms are classified into two general categories—plants and animals—according to their energy and carbon sources, structure, type of growth, and movement. Unicellular organisms are classified into three general categories—protozoa, fungi, and algae—in a manner analogous to that for multicellular eukaryotic organisms. The two domains characterized by the prokaryotic cell have distinctive differences in cellular chemistry. All of the organisms in these two divisions are microscopic, and most of the individual cells are smaller than 5 µm. Bacteria are divided into 17 major lineages (or phylums) of cultured organisms and are estimated to contain many more phylums if uncultured microbial communities are included. Classification is based on the similarity of ribosomal ribonucleic acid (RNA) sequences that have been retrieved from various environments. As will be explained later, RNA comprises approximately 20% of the dry weight of cells. The most commonly used method of categorizing bacteria by genus and species is to establish similarities in a specific type of RNA, 16S ribosomal RNA, which has a molecular weight of approximately 500 000. Bacteria include organisms of relevance in biological treatment of water and wastewater, most of the organisms of importance in soils, and most of the organisms pathogenic to humans and other mammals. A relatively small fraction of known bacterial species are agents of disease (Schroeder and Wuertz, 2003), and pathogens may be harbored within biofilms in drinking water distribution systems (Szewzyk et al., 2000) and wastewater treatment systems (Skraber et al., 2007). Three phylums have been classified as Archaea. Euryarchaeota include Extremely Halophilic Archaea in environments having salinities of 1 to 5.5 M; Methanogens, which produce methane (CH4); Thermoplasmatales, which include thermophilic and extremely acidophilic genera that require low-pH (0.5 to 4.5) and high-temperature (55 to 85°C) environments; and Hyperthermophilic Euryarchaeota, which thrive at temperatures ranging from 80 to 110 °C. Crenarchaeota, the second phylum, contains members capable of existing at either very hot or very cold temperatures. A presumptive third phylum is Korachaeota; it consists of members found at high-temperature hydrothermal environments. In most cases, organisms are identified by their genus and species, with the genus capitalized and the species non-capitalized, and both genus and species in italics or underlined. For example, organisms of the genus Pseudomonas are extremely common in both soil and biological treatment processes. Species of Pseudomonas frequently
19
20
Biofilm Reactors
found are P. aeruginosa, P. cepacia, P. putida, and P. stutzeri. Within a species, strains often are identified that behave slightly differently. For example, some strains of Pseudomonas putida may metabolize toluene, and others may not (metabolism is the sum of the processes in a living organism; materials that are metabolized are used to fuel cellular activities and incorporate to cellular molecular components). The differences between strains might be considered analogous to characteristics in humans such as height, left- or right-handedness, or ability to distinguish color. Microorganisms are defined loosely as organisms that cannot be seen by the naked eye, a definition that includes members of all of the divisions of organisms, as shown in Table 2.1. Biological treatment involves the use of microbial communities to remove or modify contaminants in water and wastewater. In most cases, the microbial communities are dominated by mixed (heterogeneous) bacterial populations (cultures made up of a number of bacterial species). A few species generally may make up the bulk of the bacterial population on either a number or mass basis. The reason that predominant species develop is the existence of a competitive advantage over less numerous groups, as a result of the particular environmental conditions or the available nutrient sources. For example, a biological process designed to remove a chlorinated aromatic compound and operating at 10 °C would almost always have at least one strain of the genus Pseudomonas among the dominant species, because this genus of bacteria is competitive at relatively low temperatures, and some species have a particular capacity to degrade aromatic compounds (Evans and Fuchs, 1988; Levin and Shapiro, 1967; Reineke and Knackmuss, 1988). Mixed bacterial populations also should be thought of in terms of interacting communities and symbiotic relationships. Overall growth and contaminant removal rates are enhanced by the interaction of the various species making up the population. In addition, interactions can be exploited further by controlling specific operational parameters in reactors. For example, some genera responsible for biological phosphorus removal require low-molecular-weight (volatile) organic acids that would not occur in significant concentrations in most wastewaters. Operating biological processes with an anaerobic segment results in fermentation (production) of volatile acids by acid-fermenting bacteria. In this manner, the substrates required by the phosphorus-removing bacteria are produced (substrate is a general term for microbial energy and/or carbon sources; the term comes from cultures grown on the surface of solid growth media, because nutrients are extracted from the substratum) (Fuhs and Chen, 1975; Levin and Shapiro, 1967, Shapiro et al., 1967). In a mixed-culture system that has not been engineered to remove nutrients, it would be expected that
Biology of Fixed-Growth Process
the various species in a mixed bacterial population produce necessary growth factors for other species as a matter of course, but this might not result in the desired reactions (e.g., phosphorus removal) taking place. In such mixed bacterial populations, species that grow most rapidly are better adapted to the particular environment (e.g., temperature, pH, or salinity) and are most efficient in energy use predominate. However, a type of hierarchy develops in which species depend on each other and in which species occupy ecological niches. For example, in a system treating gasoline production wastewaters, species that break down aromatic molecules may leave residues that serve as carbon and energy sources for species unable to break the aromatic ring. The predominant use of biological treatment is for the removal of organic compounds from water or wastewater, but removal of inorganic ions, such as ammonium, nitrate, nitrite, and phosphate, or even materials that are present in trace concentrations, such as selenium, arsenic, and mercury, is both possible and increasingly common. In addition, mixed microbial cultures can be used to produce desired end products, such as CH4. Descriptions of the structure and growth characteristics of bacterial cells and the other organisms found in biological treatment processes can be found elsewhere (Madigan et al., 2003).
3.0 MICROORGANISMS OTHER THAN BACTERIA Both microscopic multicellular and unicellular organisms have roles in fixed-growth biological treatment processes. Microscopic plants serve as surfaces on which smaller organisms grow and, through photosynthesis, as sources of oxygen. Microscopic animals serve as scavengers that remove floating debris. A few biological treatment processes have been designed that take advantage of plant growth characteristics, but the role of microscopic animals is largely uncontrolled. Unicellular eukaryotic organisms are present in most biological treatment processes. Protozoans serve a particulate scavenging role similar to multicellular animals and also may have a role in making particulate material more bioavailable to bacteria. Fungi have roles similar to the bacteria, but rarely compete well in treatment systems. Algae, like plants, can be used to provide oxygen to microbial systems and to remove inorganic nutrients, although most fixed-growth processes do not have enough light to maintain significant photosynthesis. A few biological treatment processes that take advantage of the potential contributions of algae and fungal treatment processes are under development for use with some hazardous materials (Woertz, Kinney, McIntosh, and Szaniszlo, 2001; Woertz, Kinney, and Szaniszlo, 2001).
21
22
Biofilm Reactors
Figure 2.1 Coenocytic cell structure typical of many fungi, in which cell contents, or cytoplasm, is multinucleate and continuous throughout the organism.
3.1 Fungi Fungi have cell walls, typically are coenocytic (multinucleate with no cellular subunits [see Figure 2.1]), are immotile, and use organic material for both energy and carbon sources. Inorganic contaminants, such as nitrogen, phosphorus, and other nutrients, are incorporated to cell tissue in stoichiometric amounts, as in the case of bacterial growth. Fungi grow at considerably lower rates than bacteria and do not compete well in most treatment process environments. A fungus that appears to have considerable potential in the treatment of hazardous organic compounds is Phanerochaete chrysporium, a white rot fungus. This organism produces an extracellular peroxidase that degrades lignin in the presence of peroxide. The reaction is relatively nonspecific, with respect to the type of carbon–carbon bond attacked, and has been found to be effective in initiating the degradation of a variety of highly chlorinated compounds, including the dioxins (Aust et al., 1988; Hackett et al., 1977). The use of Phanerochaete chrysporium is limited to conditions in which nitrogen is limiting, because the peroxidase is not produced otherwise. A possible application of genetic engineering would be in the transfer of the gene responsible for the synthesis of the peroxidase to bacteria that grow well in wastewater treatment processes.
3.2 Algae Algae, like the fungi, are immotile eukaryotes with cell walls. Most species are unicellular, and some form aggregates of cells, including filaments. Not all algae are microscopic. Carbon dioxide (CO2) serves as the carbon source for algal growth, and energy is derived from the absorption of light by photosynthetic pigments, with oxygen being produced as a byproduct. Because the algae are aerobic organisms, a portion of the oxygen produced is used in their metabolism. Excess oxygen accumulates in the surrounding water, as long as enough light is available. The principal wavelength range in which algae absorb light is between 300 and 700 nm.
Biology of Fixed-Growth Process
Although algae are sometimes used in nutrient removal systems, they are extremely difficult to separate from water and often are troublesome contaminants themselves. Nutrient-rich ponds, sloughs, and lakes often have algal “blooms” over short periods of time, which result in unaesthetic green mats on the water surface. The mats may be blown onto beaches, where they decay, or are problems for people using the waters for recreation. Some algal species produce organic compounds that cause taste and odors in drinking water supplies. Certain marine flagellated algae (called dinoflagellates) produce toxins that are harmful to humans and fish.
3.3 Protozoa The protozoa do not contain cell walls and use bacteria, and presumably other organisms, and particulate and soluble organic materials for food. Thus, protozoa are heterotrophic predators and, in a sense, are higher on the trophic ladder than bacteria or algae. A large number of protozoan species exist, and a number typically are seen in the microbial communities found in fixed-growth processes. Protozoa ingest some organic contaminants and use inorganic ions also. However, the numbers of protozoa present are relatively small, their growth rates are substantially lower than those of bacteria, and the amount of contaminants removed by protozoa is negligible relative to that removed by bacteria, fungi, and algae. However, they may serve to pre-process particulates for bacteria, by producing exudates of increased solubility.
3.4 Multicellular Invertebrates Higher forms of microorganisms—those with complex, invertebrate, multicellular bodies, such as rotifers and nematodes—generally act as a higher step in the food chain, but overall perform a role that is similar to the protozoa. It is quite possible for a fixed-growth process to operate successfully without the presence of protozoa or higher forms, but the presence of scavengers generally is believed to be beneficial. These organisms are present because the environmental conditions necessary for satisfactory contaminant removals often are suitable for protozoa and higher forms. Their absence in fixed-film processes often is associated with sloughing events—that is, the uncontrollable detachment of whole segments of biofilm from the support medium. The upper limit on the size of the higher forms (e.g., nematodes rather than carp) is the result of several factors, including sensitivity to oxygen concentration, physical space requirements, and growth/replication rates.
23
24
Biofilm Reactors
3.5 Viruses A group that stands alone as being nonliving, but having an effect on the growth of organisms, is the viruses. The viruses are particles composed of one or two strands of genetic material and a protective protein coat, or capsid. All viruses are obligate parasites; they are unable to carry out any form of metabolism and are completely dependent on host cells for replication. The mechanism of viral action is composed of the following four steps:
(1) Adsorption of the viral particle (viron) onto a receptor site on the cell membrane; (2) Infection—the insertion of the genetic material to the host cell; (3) Redirection of host cell functions to replication of viral particles; and (4) Release of the viral particles into the environment (often by disruption of the cell membrane, with consequent death of the cell).
Viral particles typically are 0.01 to 0.2 µm in size and are species-specific, with respect to infection. Most viral groups attack only one host species, and individuals within a species may become resistant. Viruses that attack bacteria are termed bacteriophage (or simply phage). A number of important human diseases are caused by viruses, and examples are listed in Table 2.2. Modes of transmission of hepatitis B viruses, polioviruses, and picornaviruses are known to include water, although the principal pathways typically are through food, personal contact, or exchange of body fluids. Some viruses, such as the retroviruses (including the HIV group), appear to be too fragile for water transmission to be a significant danger to public health. Viruses are important in water and wastewater treatment as contaminants to be removed. Discharge of human viruses into drinking water supplies is completely unacceptable, and the discharge of significant concentrations of human viruses with treated wastewaters is a matter of increasing concern. The role of bacteriophages in biological treatment processes is not currently understood, although phages are known to influence bacterial population dynamics in marine systems (Steward et al., 1996). Methods for monitoring the presence of human viruses are not commonly applied because of the small size of the particles and the difficulty in culturing. Some important environmental viruses cannot be grown by cell culture, at present. Increasingly, molecular biology methods based on the amplification of deoxyribonucleic acid (DNA) and, indirectly, RNA using the polymerase chain reaction (PCR) are applied to water samples (Rajal, McSwain, Thompson, Leutenegger, Kildare, and
Biology of Fixed-Growth Process
Table 2.2 Common human diseases caused by viruses (adapted from Stanier et al., 1986). Viral group and type
Disease
Herpesviruses Cytomeglovirus
Respiratory infections
Epstein–Barr virus
Mononucleosis
Herpes simplex viruses
Oral and genital cold sores
Varicella virus
Chickenpox, shingles
Hepatitus B virus
Serum hepatitus
Influenza viruses
Viral influenza and viral pneumonia
Polioviruses
Poliomyelitis
Poxviruses Orf virus
Contagious pustular dermatitis
Variola virus
Smallpox
Picornaviruses Coxsackie viruses
Herpangina
Hepatitis A virus
Infectious hepatitis
Poliomyelitis virus
Poliomyelitis
Rhinoviruses
Most colds
Parainfluenza viruses
Measles, mumps, rubella
Rhabdoviruses
Rabies
Reoviruses
Diarrheal diseases
Retroviruses Human T-cell leukemia virus
T-cell leukemia
Human immunodeficiency viruses
Acquired immunodeficiency syndrome (AIDS)
Rotaviruses
Diarrhea
Wuertz, 2007). This research now allows a more rapid and quantitative detection of viruses. A differentiation between viable or infectious and inactivated viruses by quantitative PCR is possible, in principle, but is difficult to perform at this time. At present, disinfection methods are used that have been demonstrated to be effective in
25
26
Biofilm Reactors
laboratory and field experiments. Regular monitoring of process effluents for viruses is not a conventional practice, but may become so once molecular detection methods have been validated sufficiently.
3.6 Consortia It is important to see the microorganisms used in biological treatment as a community living in consortia. Each of the organisms present occupies an ecological niche, and the relative numbers of the species will change as conditions change. For example, increases or decreases in temperature will modify the competitive advantages among the species present and result in changes in species predominance. It must be assumed that cyclic operations are more favorable to some groups than others. The ability to use particular materials, such as benzene rings or ammonia, as energy sources is not widespread among microbial species, and the presence of these materials may give some species either a niche, allowing them to survive, or a competitive advantage over other species.
4.0 CHARACTERISTICS OF BACTERIA Because bacteria are the dominant organisms in biological treatment systems, they will be discussed here in greater detail. Additional information on the other organisms commonly present in fixed-growth processes will be given as appropriate. General structural characteristics of the bacterial cell are presented here, and more detailed information can be found in other references (Ingraham et al., 1983; Madigan et al., 2003; Stanier et al., 1986).
4.1 Structure of the Bacterial Cell An overall understanding of the typical composition of bacterial cells can be obtained from Tables 2.3 and 2.4. Although the composition given is for a particular bacterial species, Escherichia coli, grown under specific conditions, the relative makeup of most bacteria is similar. The physical structure of the bacterial cell can be characterized by shape (i.e., spherical, rod, and spiral) and components, including their chemical makeup, size, and the manner in which they grow (i.e., individual cells, colonies, and filaments). Shape and size are somewhat variable with stage of growth. A species listed as a rod may appear to be spherical under some growth conditions, and cell size changes during the growth cycle. Bacteria that typically are found in groups, such as the filamentous species (which often are characterized by coenocytic cell structure),
Biology of Fixed-Growth Process
27
Table 2.3 Typical composition of Escherichia coli (adapted from Ingraham et al., 1983). Macromolecule
Percentage of Mass/cell* Molecular Number of Different kinds total dry weight grams (×1015) mass molecules per cell of molecules
Protein
55.0
155.0
RNA (ribonucleic acid)
20.5
59.0
4.0 x 104
2 360 000
1050
23 S rRNA
(31.0)
1.0 x 106
18 700
1
16 S rRNA
(16.0)
5.0 x 10
18 700
1
5 S rRNA
(1.0)
3.9 x 10
18 700
1
transfer
(8.6)
2.5 x 10
205 000
60
messenger
(2.4)
1.0 x 10
1380
400
5 4 4 6
2.13
1
DNA (deoxyribonucleic acid)
3.1
9.0
2.5 x 10
Lipid
9.1
26.0
705
22 000 000
4
Lipopolysaccharide
3.4
10.0
4346
1 200 000
1
Peptidoglycan
2.5
7.0
(904)n
1
1
Glycogen
2.5
7.0
1.0 x 10
4360
1
96.1
273.0
Soluble pool
2.9
8.0
Inorganic ions
1.0
3.0
Total macromolecules
Total dry mass/cell
284.0
Water
670.0
Total mass/cell
9
6
954.0
*Note that grams times 10 means that the actual mass has been multiplied by 10n. For example, the protein mass of an E. coli cell is approximately 155 x 10-15 g. n
grow as single cells also. Thus, visual observation does not provide a method of species identification. Current molecular methods of identification and classification are based primarily on similarity of 16S ribosomal RNA or detection of specific genes. For example, intact cells belonging to the Bacteria and Archaea domains can be tested with fluorescently labeled genetic probes (short sequences of DNA that can penetrate most microbial cells). The probes are single-stranded and bind to 16S rRNA in the cell. Only perfect matches of sequences will lead to retention of the probe in the cell after a sequence of hybridization and washing steps. With the aid of a good fluorescent
28
Biofilm Reactors
Table 2.4 Typical elemental composition of bacterial cells (Stanier et al., 1986). Element Carbon Oxygen Nitrogen Hydrogen Phosphorus Sulfur Potassium Sodium Calcium Magnesium Chlorine Iron ΣTrace elements
Percent of dry weight General physiological function 50 20 14 8 3 1 1 1 0.5 0.5 0.5 0.2 0.3
Constituent of organic cell materials Constituent of organic cell materials and cellular water Constituent of proteins, nucleic acids, coenzymes Constituent of cellular water and organic cell materials Constituent of nucleic acids, phospholipids, coenzymes Constituent of proteins and coenzymes Major cation in cell processes Major cation in cell processes Major cation in cell processes and enzyme cofactor Major cation in cell processes, cofactor in ATP reactions Major anion in cell processes Constituent of cytochromes and other proteins, enzyme cofactor Inorganic contituents of special enzymes
microscope, it is possible to verify in situ the presence or absence of certain groups of prokaryotes in a biofilm (Wilderer et al, 2002). Other methods include immunoassays and fatty acid methyl ester analysis and phospholipid fatty acid analysis, which are used to develop unique “fingerprints” of species and consortia, bacterial metabolism, resistance to antibiotics, and chemical characteristics of the cell wall. The nature of the structural components of the cell is of considerable interest in biological treatment. Reference can be made to Figure 2.2 in discussing the most important components relative to contaminant removal—the genetic component, enzymes, storage bodies, cytoplasmic (cell) membrane, cell wall, and bound extracellular polymeric substances (EPSs, often referred to as capsule). Bound EPS is associated closely with cells, but its polymers are not anchored in the cell envelope (Nielsen and Jahn, 1999). Strictly speaking, EPSs are not part of the cell structure but are included here because of their importance in biofilms and the difficulty of physically separating bound EPSs from cells (Spaeth and Wuertz, 2000).
4.2 Chromosome and Plasmids The genetic component of bacterial cells (the genome) includes both the single DNA molecule, called chromosome, and relatively small DNA circlets, called plasmids, located in the cytoplasm. The chromosome is circular and double-stranded, with a length greater than 1000 µm and a molecular weight of approximately 109. Because bacterial
Plasmid
Ce ll Membrane
Cell Wall Nucleoid DNA
Capsule Pilus
Biology of Fixed-Growth Process
Flagellum
Cytoplasm Includes: RNA, protein, plasmids (DNA), volutin granules (polyphosphates, sulfur), storage products (glycogen, lipids)
Figure 2.2 Schematic representation of the bacterial cell. Note that particular bacterial species are characterized by general shape and the tendency to occur singly, in clumps, or as chains or filaments. Typical cell sizes, excluding the capsule, range from 0.5 to 2 µm. The capsule is considered part of the EPS, and its size tends to be very small during rapid growth.
cells are approximately 1 to 2 µm in length or diameter, and the nuclear region is only a small part of the cell, the chromosome must be folded tightly. The chromosomal DNA is essential to the life of a cell. Without it, the information required for the production of necessary enzymes and other structures necessary for growth is missing. Damage to the DNA can result in the loss of an essential activity and death. Plasmids consist of extrachromosomal, typically circular, double-stranded DNA and typically are not a required component of the cell, but they seem to provide particular capabilities that make a strain more or less competitive in a given environment. These include resistance to specific antibiotics, toxin production, ability to metabolize unusual compounds or ions, and possibly resistance to attack by bacteriophage.
29
30
Biofilm Reactors
4.3 Cytoplasm The tightly packed, granular region within the cytoplasmic membrane is the cytoplasm. Principal components of the cytoplasm are the ribosomes, made up of RNA and proteins, where other cell components are synthesized; enzymes (proteins), which catalyze necessary chemical reactions; plasmids, organic and inorganic compounds involved in metabolism; and granular inclusions containing storage materials, such as glycogen and poly-β-hydroxybuterate (PHB), polyphosphate (volutin granules), and sulfur. Carbon storage as glycogen or PHB appears to be speciesdependent. Enteric bacteria, cyanobacteria (blue-green algae), and spore-forming bacteria tend to store the glucose polymer, glycogen, while groups commonly found in soil, such as pseudomonads and rhizobia, tend to store PHB. Some groups (e.g., Acinetobacter and possibly the filamentous bacteria) do not store carbon, which is a factor in their competitiveness under feast/famine conditions. Glycogen granules are detectable only using electron microscopy (Ingraham et al., 1983) and are relatively evenly distributed. Poly-β-hydroxybuterate, polyphosphate (or volutin), and sulfur granules often can be seen, with special stains applied to slides, as refractile bodies under conventional light or fluorescent microscopy (Serafim et al., 2002). The intracellular accumulation of large amounts of polyphosphate granules in some bacterial species under cyclic anaerobic or anoxic/aerobic operation is used in enhanced biological phosphorus removal processes (Kong et al., 2005).
4.4 Cell Membrane Surrounding the cytoplasm is a bilayer unit membrane composed primarily of phospholipids and proteins. The cell membrane acts as an osmotic barrier (phospholipid function) and has specific transport functions (protein function), in which transferase enzymes carry out transport reactions for specific molecules. In aerobic bacterial cells—those that use oxygen as a terminal electron acceptor—the electron transport system of enzymes, in which the energy-rich compound ATP is produced and oxygen is consumed, is attached to the cell membrane. The typical thickness of the cell membrane is approximately 7 to 8 nm.
4.5 Cell Wall Structural strength is provided by the cell wall. However, this structure also acts as a molecular sieve, which screens out toxic molecules and antibiotics, and contains binding and hydrolytic enzymes, which aid in nutrient gathering and transport.
Biology of Fixed-Growth Process
In bacteria, two general types of cell envelopes are identified by the Gram-stain process, in which an applied dye is found to be permanently fixed (positive) or washed out of the cell (negative). Both types have cell walls made of peptidoglycan. Gram-positive bacteria have a thicker cell wall, and many species also have acidic polysaccharides, called teichoic acids. They often are resistant to desiccation and are found more commonly in soil and other oligotrophic environments. Many bacteria found in wastewater reactors are Gram-negative. Their cell envelope includes a thinner cell wall made of peptidoglycan and a second (outer) membrane, in addition to the cell membrane. Archaea have cell walls made up of a variety of components, but not peptidoglycan.
4.6 Pili Single strands of protein originating in the cell membrane and extending approximately 10 µm from the cell wall are the pili. These hairlike apparati appear to have a function of binding the cell to specific structures. For example, pili are required to establish cell-to-cell contact in the transfer of plasmids from one cell to another, in the process of bacterial conjugation. The presence of pili on the cell surface can aid the initial cell adhesion to interfaces. A specific type of pilus, type IV, also has been shown to be involved in cell movement (Mattick, 2002) and movement of biofilms across solid surfaces by retracting the pilus and pulling the cell forward (HallStoodley et al., 2004).
4.7 Flagella The long (15 to 20 µm) filament called the flagella moves the bacterial cell with a whiplike rotational motion. Movement of motile bacteria (not all species have such structures) toward favorable environments is a complex response to chemical gradients and “attractant solutes” in the cell’s surroundings.
4.8 Extracellular Polymeric Substances A polysaccharide layer is secreted by many bacteria. The size of this amorphous capsule or glycocalyx may be larger than the cell, in some cases. In addition, there are many other macromolecules that are either actively secreted or released through cell leakage and cell death. They include proteins and nucleic acids (DNA and RNA). The EPS can act as a binding agent, attaching cells onto surfaces, such as fixed-growth packing media, rocks, pipes, and teeth, or to other cells to form microbial aggregates
31
32
Biofilm Reactors
in the form of biofilms and flocs. Initial adhesion to interfaces also is facilitated by the cell appendages, such as the pili discussed above. Once a biofilm is developing, the cellular EPS production is increased (Venugopalan et al., 2005). An operational definition of EPS distinguishes between bound and soluble EPS (Nielsen and Jahn, 1999).
4.9 Chemical Composition of Cells In most engineering problems, the fundamental composition and structure of microbial cells is of less importance than overall size (typically 1 to 5 µm for bacterial cells) and elemental chemical composition. The principal elements of all living cells, on a mass basis, are carbon, oxygen, nitrogen, hydrogen, phosphorus, and sulfur. A number of metals (iron, manganese, potassium, cobalt, calcium, copper, and zinc) are essential to life, because they serve as cofactors (or mediators) to the electron transport that takes place in specific enyzyme-catalyzed reactions. Empirical cell formulas, or molar ratios, of the chemical constituents of microbial cells are used to estimate nutrient requirements for growth and convert gravimetric cell mass measurements into theoretical oxygen demand of cell tissue. The most widely used empirical cell formula, C5H7NO2 (Porges et al., 1953, Rittman and McCarty, 2001), omits the essential nutrient phosphorus. Inclusion of phosphorus results in considerably more complex formulas, such as C42H100N11O13P (McCarty, 1965). Empirical cell formulas are representative of growth under specific environmental conditions, and care must be used in general application of the relationships, as can be seen in the following example.
4.10 Example 1—Theoretical Oxygen Demand of Bacterial Cells Determine the theoretical oxygen demand of 1 g (dry) of microbial cells using the two empirical cell formulas given above. Assume that organic nitrogen in the cells is not oxidized and remains in the -3 oxidation state.
4.10.1 Solution The solution can be obtained as follows:
(1) Write a stoichiometric equation for the oxidation of C5H7NO2. C5H7NO2 + 5O2 → 5CO2 + NH3 + 2H2O (2) Determine the ThOD of 1 g of C5H7NO2 Empirical molecular weight = 113
Biology of Fixed-Growth Process
1 g = 0.008 85 mol 5 mol of O2 is required per empirical mole of cells (0.008 85 mol cells)(5 moles O2/mol cells)(32 g O2/mol O2) = 1.42 g
(3) Write a stoichiometric equation for the oxidation of C42H100N11O13P
2C42H100N11O13P + 107 O2 = 84CO2 + 22NH3 + 64H2O + 6H+ + 2PO4– 3 Empirical molecular weight = 997 1 g = 0.001 00 mol 53.5 mol of O2 are required per empirical mole of cells (0.001 mol cells)(53.5 mol O2/mol cells)(32 g O2/mol O2) = 1.71 g
4.10.2 Comment Note the large difference in oxygen demand that would be predicted for the same mass of cells from application of the two empirical formulas. The empirical formula used most commonly, C5H7NO2, was developed based on cells grown on a case in medium, and the general validity is not well-established.
5.0 B ACTERIAL METABOLISM, NUTRITION, AND RESPIRATION Microbial metabolism of interest in water and wastewater treatment is divided into the following two major categories: • Catabolism—the breakdown or degradation of materials with the concomitant release of energy, and • Anabolism—the synthesis of new cellular materials using the energy released in catabolism and the breakdown products of catabolism. Metabolism also can be described by the type of energy source used (e.g., organic compounds, inorganic ions, and light). Emphasis in this section will be placed on catabolism, while anabolism will be discussed in the Viruses and Consortia sections, dealing specifically with microbial growth. Nutrition, as defined here, is related to the chemical requirements associated with microbial metabolism. Most of the bacteria found in soils and natural waters and those used in wastewater treatment are not very fastidious, with respect to nutrition. Inorganic nutrient sources, such as ammonia and nitrate for nitrogen or phosphate for phosphorus, are satisfactory, and a relatively
33
34
Biofilm Reactors
wide variety of organic materials can be used as energy sources. A few microorganisms found in natural systems, such as the nitrifiers and the methanogenic bacteria, have tightly constrained nutrient requirements. Microbial respiration is defined by the type of terminal electron acceptor used in the energy-yielding reaction processes and can be classified generally as aerobic, anoxic, or anaerobic and by the electron acceptor used (aerobic, anoxic, or anaerobic). A summary of bacterial metabolism and respiration is given in Tables 2.5 and 2.6, and more detailed discussions can be found in Lengeler et al. (Eds., 1999) and Madigan et al. (2003).
Table 2.5 Classification of living organisms by carbon and energy sources. Classification
Carbon source
Energy source
Autotroph
CO2
—
Heterotroph
Organic compounds
—
Chemotroph
—
Chemical compounds
Chemolithotroph
—
Inorganic compounds
Chemoorganotroph
—
Organic compounds
Phototroph
—
Light
Chemoautotroph
CO2
Chemical compounds
Photoautotroph
CO2
Light
Chemoheterotroph
Organic compounds
Chemical compounds
Photoheterotroph
Organic compounds
Light
Methylotroph
1-carbon compounds
1-carbon compounds
General
Other terms Eutroph
Use high concentrations for carbon and energy
Oligotroph
Use low concentrations for carbon and energy
Zymogenous
Grow rapidly when carbon and energy source added
Saprophyte
Live off of dead organic matter
Table 2.6 Bacterial metabolism and respiration. Electron acceptor
Principal non-cell product
Microbial group
O2
CO2, H2O
NO3–, NO2– SO4–2 Fe3+ , ClO4–
CO2, , N2, N2O CO2, H2S, S0 CO2, Fe+2 CO2, Cl-
CO2 Organic metabolites
CO2, CH4 Volatile acids, alcohols
Aerobic heterotrophs Denitrifiers Sulfate reducers Iron reducers Perchlorate reducers Methanogens Fermenters
O2
CO2, NO2
NH3
NO2–
N2, H2O, NO3–
NO2– H2 H2S H2 H2 Light (≈870 nm)*, H2S
O2 NO3–, NO2– O2 CO2 SO4–2 CO2
CO2, NO3– CO2, , N2, N2O CO2, SO3–2 CH4 H2S, H2O
Type of metabolism Electron donor Chemoheterotrophic
35
Chemoautotrophic
–
Photoheterotrophic Photoautotrophic *Energy source
Organic compounds
Inorganic compounds NH3
Light (450 to 650 nm)*, H2O Light (≈870 nm)*, H2S
Carbon source Organic compounds
CO2
Organic compounds CO2 O2 CO2 CO2
SO3–2, H2O O2, H2O SO3–2, H2O
Ammonia oxidizers Anaerobic ammonium oxidizers Nitrite oxidizers Denitrifiers Sulfide oxidizers Methanogens Sulfate reducers Phototrophs Phototrophs Phototrophs
36
Biofilm Reactors
5.1 Energy Source Three types of energy source are used by bacteria—organic compounds (chemoheterotrophic metabolism), inorganic compounds (chemoautotrophic metabolism), and radiant energy (photosynthetic metabolism). In general, a single species does not use more than one type of energy source, and, for this reason, bacteria often are classified as chemoheterotrophic, chemoautotrophic, or photosynthetic. For example, the Pseudomonads, a common soil bacterial genus, are all chemoheterotrophic. In wastewater treatment, the most important groups of bacteria are chemoheterotrophic. However, the chemoautotrophic nitrifying bacteria are essential in processes where ammonia-nitrogen removal is required. The photosynthetic Cyanobacteria (formerly blue-green algae) are essential components of wastewater treatment processes, such as oxidation ponds and artificial marshes.
5.2 Chemoheterotrophic Metabolism Organic material serves as both an energy and carbon source in chemoheterotrophic (typically shortened to heterotrophic) metabolism. Bacteria are able to use a wide variety of organic materials as food or “substrate,” including complex molecules, such as protein and starches, and many anthropogenic compounds, such as chlorobenzoate and pentachlorophenol. Most bacterial species are capable of metabolizing, or partially metabolizing, a relatively large number of compounds. However, the rates of metabolism of specific compounds vary significantly among species, and, in cases where a mixture of organics are available, a large number of species will grow as a consortium that, in some manner, appears to provide the most efficient biodegradative community. Nearly all naturally occurring organic compounds can be degraded by at least one species of bacteria. However, a number of synthetic organic compounds that have no naturally occurring counterparts (termed xenobiotics after the Greek word xeno, or stranger) have proven difficult to degrade biologically (Madigan et al., 2003; Reineke and Knackmuss, 1988; Rittman and McCarty, 2001). Examples include multi-ring compounds, such as the pesticides Dieldrin, a chlorinated hydrocarbon originally produced in 1948 by J. Hyman & Co., Denver, Colorado, and toxephene; the polychlorinated biphenyls; and chlorinated volatile organic compounds, such as the solvents trichloroethylene (TCE), tetrachloroethylene, and 1,1,2-trichloroethane, which are shown in Figure 2.3. Chlorendic acid is used as a “builder” for other chemicals, many of which are pesticides. Over 200 polychlorinated biphenyls exist. The compounds were used principally as insulators in electrical transformers, but currently are not manufactured in the
Biology of Fixed-Growth Process
Cl
Cl
Cl
Cl
Cl Cl
Cl
COOH Cl Cl
COOH
Chlorendic Acid
Cl Cl A Polychlorinated Biphenyl
Benzene
OH
Napthalene
Phenol
Phenanthrene
Cl
Cl
Cl
Cl
C
C
C
C
Cl Cl Cl H Trichloroethylene Tetrachloroethylene
H
Cl
Cl
C
C
H
Cl H 1,1,2-Trichloroethane
Figure 2.3 Examples of organic compounds that are toxic and/or difficult to biooxidize.
United States because of their carcinogenicity. Benzene is easily degraded biologically, but is highly carcinogenic. Phenol is biodegradable at low concentrations. Napthalene and Phenanthrene are among the most common polynuclear aromatic hydrocarbons. The chlorinated aliphatic solvents TCE, tetrachloroethylene (perchloroethylene, perc, or PCE), and 1,1,2-trichoroethane (1,1,2-TCA) are commonly used chlorinated solvents. Non-degradable xenobiotic compounds are a matter of current concern because of potential toxicity to living organisms. Many have been accumulating in the food chain, and effects of the accumulation, such as decreases in bird reproduction rates, loss of fisheries, and increases in specific malignant tumors, are being discovered continually. Materials that are slow or impossible to break down biologically are referred to as recalcitrant or refractive. Some naturally occurring compounds are refractive. These include cellulose and lignin, both of which are associated with plant fiber. Cellulose is a particularly interesting compound because it is, like starch, a polymer of glucose. Both starch and glucose are easily broken down by a wide variety of bacteria and most other heterotrophic organisms. Starch is broken up into small subunits in reactions catalyzed by enzymes, such as α-amylase and maltase, which break the α-glycosidic bond (Figure 2.4)
37
38
Biofilm Reactors
HOCH2 H
H
H
OH
O
HOCH O
H
H O
H
2
H
OH
O H
OH
H
H
OH
O
α − glycosidic bond a. Repeating unit of starch and glycogen
HOCH
O
H
2
H
HOCH O
OH
H
H
OH
H
O
H
2
H OH H
O
H
H
O
OH
β − glycosidic bond
b. Repeating unit of cellulose
Figure 2.4 Repeating glucose units of starch and glycogen connected by α-glycosidic bonds and cellulose connected by β-glycosidic bonds.
between the glucose molecules. The bond between the glucose molecules of cellulose is a β-glycosidic bond (a mirror image of the α-glycosidic bond), and the enzymes that catalyze the cleavage reaction are unusual in bacteria but common in the fungi. Bacteria in the aerobic Actinomycete group and a few anaerobic heterotrophic bacteria, notably some Clostridia, found in such places as the intestines of termites and certain anaerobic environments, produce the enzyme, but it is lacking in most aerobic species.
5.3 Chemoautotrophic Metabolism Organisms capable of using CO2 or bicarbonate (HCO3–) as a carbon source and a reduced inorganic chemical, such as hydrogen (H2), ammonia (NH3) (or ammonium [NH4+]), nitrite (NO2–), Fe2+, hydrogen sulfide (H2S), or elemental sulfur (S0), as an energy source are referred to as chemolithotrophic, chemoautotrophic, or, more commonly, autotrophic. Specific groups of bacteria oxidize each of the above materials. The ammonia oxidizers (Nitosomonas, Nitrosospira, and Nitrosococcus are the predominant genera) and nitrite oxidizers (Nitrobacter and Nitrospira are the predominant
Biology of Fixed-Growth Process
H O + O2 + FeS 2(s) 2
-2 + H+ 2
Fe +2 + S
_ +2 2 Fe + SO4
+3 Fe + H2 O O 2 + H+
H 2O
Fe(OH)
3(s) +
H+
Figure 2.5 Schematic of reactions through which pyrite [FeS2(s)] is oxidized in mine drainage. Note that the stoichiometry is not shown. genera) are the autotrophs of major interest in biological treatment. Sulfur-oxidizing bacteria (the aerobic Thiobacillus, Thiotrix, and Beggiatoa and the anaerobic photosynthetic green and purple bacteria) are important in many environments, including wastewater collection systems. Sulfides and thiosulfate are oxidized by these bacteria in the aerobic liquid film that forms on the upper surface of open-channel pipes, and the oxidation product is sulfuric acid. The resulting corrosion is difficult to control and results in severe maintenance problems. Iron bacteria cause corrosion in many industrial systems, and species such as Thiobacillus ferrooxidans, Thiobacillis thiooxidans, and Ferobacillis ferrooxidans are responsible for the production of acid mine drainage through catalysis of the reaction Fe+2 → Fe+3 + e-. Oxidation of Fe+2 in mine drainage occurs spontaneously under some conditions, but the bacterially mediated corrosion reaction is 106 times faster (Singer and Stumm, 1970). Acid mine drainage is a major problem in most coal and copper mining areas. The reactions are summarized in Figure 2.5. Molecular hydrogen is a common product in the anaerobic bacterial breakdown of organic materials. If H2 accumulates in a reaction system, organic breakdown will cease and, therefore, a mechanism for removal must be present. Autotrophic conversion of molecular hydrogen and CO2 to CH4 by anaerobic methane-fermenting Archaea is an important process in the treatment of organic sludges and is essential to the functioning of ruminant animals.
5.4 Photosynthetic Metabolism A small number of bacterial species obtain their energy for growth from light and their carbon for growth from CO2 or HCO3–. One group, the Cyanobacteria, formerly known as blue-green algae, carries out oxygenic photosynthesis, in which molecular
39
40
Biofilm Reactors
oxygen is a product. Blue-green bacteria are important in oxidation ponds, a type of biological wastewater treatment process. Other photosynthetic bacteria may occur in overloaded oxidation ponds but are not of importance in biological treatment systems under normal operating conditions. Cyanobacteria have chlorophyll that absorbs light in the 800- to 900-nm wavelength range, and the principal mode of growth is light adsorption with concomitant lysis of H2O. Oxygen is a byproduct, and CO2 is assimilated as the carbon source. Ammonia and nitrate both are used as nitrogen sources. A number of Cyanobacteria species can fix nitrogen. Simple organic compounds can be used as carbon, but not as energy sources, by a number of Cyanobacteria species, and a few species can grow heterotrophically. Thus, the Cyanobacteria are extraordinarily adaptable microorganisms, in terms of their nutrition, and it is not surprising that they predominate in many natural environments. Fixed-growth biological treatment processes do not provide suitable conditions for their growth, however, and the use of Cyanobacteria essentially is limited to faculative and aerobic oxidation ponds. Anoxygenic photosynthesis is carried out by two other groups of phototrophic bacteria—the Rhodospirillaceae, or purple nonsulfur bacteria, and the Chlorobiaceae, or green bacteria. Anoxygenic photosynthesis does not result in oxygen generation and does not occur in the presence of oxygen. The principal wavelengths absorbed by the phototrophic bacteria are between 400 and 500 nm and 700 and 1000 nm. A number of species can grow heterotrophically on simple sugars, amino acids, and organic acids. Although these bacteria typically are considered anaerobes, most are not extremely sensitive to oxygen, and many can grow in micro-aerophilic environments. Neither the green or purple bacteria are of great importance in fixed-growth systems.
5.5 Nutrient Requirements Microbial metabolism is directed toward reproduction of the organisms, and this requires that chemical constituents of cell components are available for assimilation and incorporation to new cell components. The elements listed in Table 2.4 are required in the approximate proportions given. Note that the two empirical formulas given above in the Chemical Composition of Cells section have approximately the same percentages of the principal elements. For example, in the empirical formula C5H7NO2, the percentages of carbon, hydrogen, nitrogen, and oxygen on a mass basis are 53, 6, 12, and 28, respectively. Nutrients typically are assimilated from a limited number of elemental states; therefore, both the amount of nutrients present and the state of the nutrients are
Biology of Fixed-Growth Process
important. For example, heterotrophic bacteria require carbon in the organic form. Many bacterial species are able to use only a limited range of organic compounds. Only a few species are capable of metabolizing the 5-carbon sugar lactose in the absence of oxygen, and this property is used to determine the presence of coliform organisms (species that are common in the gut of warm-blooded animals) in water samples. The most probable number test for coliform bacteria is constructed on the basis of this fact. Most bacteria can assimilate nitrogen in the ammonia (-3), nitrite (+3), and nitrate (+5) oxidation states. Sulfur assimilation typically is from the sulfate (+6) oxidation state. Metals are assimilated from the ionic state, in almost all cases. Often one or two nutrients in the environment limit microbial growth. The limiting nutrient concept is useful in predicting the effects of pollutants on receiving waters and in designing and operating biological treatment processes. The Great Lakes in the United States and Canada are phosphorus-limited, and the increases in phosphorus inflow rates that resulted from the introduction of biodegradable detergents in the late 1960s greatly increased the rates of eutrophication. The removal of phosphorus from wastewater discharges to tributaries of the Great Lakes was an application of the limiting-nutrient concept. Many industrial wastewaters are unbalanced, with respect to nutrients, and stoichiometric additions of the growth-limiting nutrients (typically nitrogen and/or phosphorus) must be made.
5.6 Bacterial Energy Metabolism Respiration is the mechanism through which the electrons removed from energy sources are discharged to the cell’s external environment and when use of a terminal electron acceptor is coupled to energy production. Typically, respiration involves a series of oxidation–reduction (redox) reactions, but the final step involving a terminal electron acceptor defines the type of respiration occurring. Two types of respiration occur—aerobic, in which molecular oxygen serves as a terminal electron acceptor, and anaerobic, in which inorganic compounds or ions, such as nitrate (NO3–), sulfate (SO4–2), S0, CO2, Fe3+, Mn4+, SeO4–2, AsO33–, and ClO4–, or organic compounds, such as fumarate, chlorobenzoate, and dimethyl sulfoxide, serve as the terminal electron acceptor. The terminal electron acceptor is discharged by the cell to the environment; thus, the use of organic compounds as electron acceptors results in the discharge of organics to the liquid outside the cell. Fermentation reactions are used by bacteria to catabolize organic compounds when there is no external electron acceptor available. The organic substrate is used as the electron donor, and the electron acceptor is a high-energy intermediate product
41
42
Biofilm Reactors
of the transformation of the donor that can yield ATP (the energy currency of life systems) via substrate-level phosphorylation. There are several types of fermentations, and some, such as the production of CH4 from acetate, are of importance in fixed-film processes.
5.7 Aerobic Growth and Respiration The use of oxygen as a required terminal electron acceptor is the principal characteristic of aerobic metabolism. Heterotrophic metabolism will be used as the model in this section, although important autotrophic organisms, such as the nitrifiers, are also aerobes. Biological treatment systems nearly always are made up of mixed microbial populations, and, because of the metabolic interactions of the various species, the principal end-products of heterotrophic aerobic growth and respiration are new microbial cells, CO2, and water (H2O). Other products may be produced in significant quantities, but this is not the general case. Models of aerobic metabolism generally are based on the conceptual expression given in eq 2.1.
New Organic + O 2 + Nutrients → bacterial + CO 2 + H 2 O matter cells
(2.1)
The new microbial mass term in eq 2.1 includes all synthesized materials, including microbial exopolymers. Experimentally, the value of the new microbial mass term is measured as the increase in either suspended or volatile suspended solids (VSS). Volatile suspended solids measure only organic solids and are better suited to describe biomass in a reactor. Writing eq 2.1 in the form of a stoichiometric balance is not possible in the general sense, because conversions are related to the characteristics of the organic material, the species of organisms present, and the treatment system operating characteristics. However, development of stoichiometric expressions is a necessary step in treatment process design, because estimates of both oxygen requirements and excess solids production must be made. In nearly all applications of biological treatment, a mixture of organic compounds is present, some of which are soluble and some of which are in the particulate form. This situation complicates the application of stoichiometric relationships, because the mixed microbial populations generally attack a wide variety of soluble and particulate materials simultaneously. The result is that surrogate variables for the organic reactant concentration must be used.
Biology of Fixed-Growth Process
The most common surrogate variable is the biochemical oxygen demand (BOD), although chemical oxygen demand (COD) and total organic carbon (TOC) are used, to some extent. In most cases, the BOD value reported in laboratory analyses is the 5-day, 20 °C value. However, the BOD value that represents the concentration of biodegradable organic material present is the ultimate BOD (UBOD). If the systems used in biological treatment were mathematically linear, the BOD5 value could be used, but this is not the case. Thus, care should be taken in process design to ensure that UBOD values are estimated and used in calculations. Models used to evaluate and design wastewater treatment processes generally use COD as a basis for quantifying the strength of the wastewater. This is because COD provides a consistent and convenient method for computing mass balances, which are fundamental to calculating, for example, the carbon entering and leaving a process, waste sludge produced, and oxygen consumed. The COD measures the electron-donating capacity of organic material, and, because electrons cannot be created or destroyed, it provides a conservative basis for these calculations. The issue of how much of the COD represents biodegradable organic matter is dealt with by characterizing the COD in terms of its different fractions. This is discussed further in Chapter 11 on modeling.
5.8 Anoxic Conditions and Respiration Anoxic conditions will be defined to occur when oxygen is absent from the liquid environment, or present at very low levels, and either NO3– or NO2– are available as the exogenous (from outside the cell) terminal electron acceptor. Anaerobic respiration is applied to situations where CO2, SO4–2, or certain organic compounds are available as terminal electron acceptors. While commonly used in environmental engineering practice, this differentiation is not made in the discipline of microbiology, and metabolism is termed aerobic, anaerobic, or fermentative. The term anoxic then is reserved to describe an environment that is free of molecular oxygen. We will adhere to the usage in environmental and wastewater engineering, but caution the reader about conflicting definitions and uses in the literature. A large number of heterotrophic bacterial species are capable of reducing NO3– to NO2– in a manner analogous to the use of oxygen as a terminal electron acceptor. These bacteria are all members of a group termed facultative anaerobes; that is, they can metabolize and grow under aerobic or anaerobic environments. A smaller number of heterotrophic facultative anaerobes are able to reduce NO2– to gaseous N2O and N2, with the end product distribution determined by the pH of the liquid. The organic
43
44
Biofilm Reactors
materials used to drive the reduction processes (termed denitrification or dissimilatory nitrate reduction) are quite varied. Single carbon compounds, such as methanol, CH3OH, can be used, in addition to the more conventional types of organics found in domestic wastes. A second type of NO3– and NO2– reduction, termed assimilatory reduction, is used by many species of bacteria to produce a –3 oxidation state nitrogen for incorporation to organic molecules, such as the amino acids that make up protein molecules. Assimilatory reduction is not tied to energy metabolism, is not analogous to the use of oxygen in aerobic respiration, and occurs under both aerobic and anaerobic conditions. Because energy is expended in reducing NO3– and NO2–, the mass yield of microorganisms will be lower than for systems where NH3 is the nitrogen source. Both obligate aerobes and facultative anaerobes can carry out assimilatory reduction. Nitrogen compounds also can be removed from wastewater using anoxic ammonia oxidation (anammox), with NH4+ acting as an electron donor and NO2– as a terminal electron acceptor. This process is carried out by slow-growing bacteria of the Planctomycetes phylum of Bacteria, which are autotrophic. In biofilms, there exist both oxic and anoxic zones; hence, aerobic nitrifiers produce the NO2– that becomes the electron acceptor necessary for the anammox process.
5.9 Anaerobic Respiration and Fermentative Metabolism The common anaerobic terminal electron acceptors of importance are SO4–2 and CO2. Ferric (Fe+3) ion also is used by some bacteria, including many of those that reduce NO3–. However, the insolubility of Fe+3 makes the ion an insignificant factor as an electron acceptor in the biological treatment of water. The bacterial species capable of dissimilatory SO4–2 reduction are not numerous (limited to approximately 8 genera), and the reaction product, hydrogen sulfide (H2S) typically is noticeable because of its odor. All of the SO4–2 reducers are obligate anaerobes; that is, they do not grow in the presence of oxygen. Common energy sources for dissimilatory SO4–2 reduction are H2, lactic acid, and pyruvic acid. As in the case of NO3–, a large number of bacterial species, both aerobic and anaerobic, can reduce SO4–2 in an assimilatory manner. The ability to reduce SO4–2 is almost essential for organisms growing in soil and water, because nearly all of the available sulfur is in the SO4–2 form. Carbonate respiration involves H 2 as an electron donor and CO 2 as a terminal electron acceptor; it can lead to the formation of CH4 (in methanogenesis),
Biology of Fixed-Growth Process
carried out by a limited number of genera belonging to the Archaea, or acetate (in acetogenesis), which is performed by homoacetogens belonging to the Bacteria. Both groups are strictly anaerobic. Similar to NO3– and SO4–2, there also are a great number of species belonging to all three domains of life that can assimilate CO 2 as a nutrient source without concurrent use as an electron acceptor under aerobic or anaerobic conditions. The use of electron acceptors—those produced within the cells or by other cells— results in the fermentation of a variety of relatively low-molecular-weight organic compounds. Typical products are low-molecular-weight (volatile) organic acids, alcohols, and aldehydes. The principal volatile acids produced are formic, acetic, propionic, and butyric, with acetic being the most important. Methanogenic members of the Archaea, such as Methanosaeta and Methanosarcina, oxidize acetic and formic acids with the concomitant production of CH4 and CO2. Hence, they are distinct from autotrophic methanogens using H2 as an energy source and reducing CO2 (or HCO3–) as a terminal electron acceptor to CH4. Anaerobic growth by fermentation and respiration can be used to completely remove organic materials from water and wastewater only if methane fermentation is included as a step in the process. Methanogens are the final link in a series of interdependent biochemical reactions involving different organisms (termed syntrophic reactions), which characterize anaerobic environments in fixed-growth reactors treating biological waste. The concept is attractive, because the methane has a very low solubility and can be collected and used as a fuel. However, the energy for growth derived from methane fermentation is relatively small, and the rates associated with growth are low. Economic operating conditions generally require that operating temperatures be in the range 30 to 35 °C, which requires that the reactors be heated. Generation of sufficient methane to heat the systems requires that strong, or high-concentration, organic feed solutions are used. Organic sludges produced in wastewater treatment plants (WWTPs) and industrial wastewaters, such as those from food-processing industries, are the principal candidates for application of anaerobic fermentation treatment processes. Anaerobic sludge digestion is one of the most common methods of stabilizing sludges resulting from wastewater treatment, and sufficient excess methane often is produced to allow heating of buildings and, in some cases, production of electricity. In addition, low-temperature (<20 °C) anaerobic treatment of wastewater is possible using fixed-growth processes, but more insights to microbial community changes are needed to ensure stable maintenance of reactor operations (Enright et al., 2007).
45
46
Biofilm Reactors
5.10 Energetics of Respiration The molar free energy released or consumed in a reversible reaction is given by eq 2.2.
∆G = ∆Go + RTlnQ
(2.2)
Where ∆G = free energy change, kJ/mol; ∆Go = standard free energy change, kJ/mol; T = absolute temperature, Kelvin (K); R = universal gas constant, J/K mol; and Q = reaction quotient (Q ≈ K, the equilibrium coefficient in dilute solutions). Electrical potential (in volts) can be related to the free energy change by the Nernst equation, as follows:
∆G = –nFE
(2.3)
Where n = number of electrons transferred in the reaction, and F = Faraday’s constant (9.649 × 104 J/mol∙V). In practice, ∆E is referenced to the standard hydrogen electrode for which a standard free energy change, ∆Go, of 0 is assigned to the half-reaction when the reaction quotient, Q, is equal to 1. 1/ 2 [H2 ] 1 + H + e– = 2 H2(gas) Q = = 1 (2.4) H + Note that, by convention, the activity of a gas is 1 and, therefore, [H+] = 1. Electrical potentials relative to the standard hydrogen electrode are designated by EH and, therefore,
∆G = -nFEH
(2.5)
Substitution of eq 2.5 into eq 2.2 gives the following:
–nFEH = –nF EHo + RTlnQ EH = EHo –
RT ln Q nF
(2.6) (2.7)
For the hydrogen ion reaction of eq 2.2, the standard free energy, ∆Go, is set equal to zero by convention; therefore, the standard electrode potential is also zero. Reactions in the environment typically occur under nonstandard conditions, that is, when the reaction quotient for the hydrogen ion reaction of eq 2.2 is not equal to 1
Biology of Fixed-Growth Process
and the temperature is not equal to 0. Comparisons typically are made for pH = 7 and 25 °C, where the standard potential is as follows: 1/ 2 RT RT [1] EH(W) = EHo – ln Q = 0 – ln −7 nF nF 10 (8.31J / mol ⋅ K )(293K ) ln 107 (1)(9.649x10 4 J / mol ⋅ V )
= −
= 0.0257(16.12) = –0.407 V
Standard potentials for selected environmentally important half-reactions are given in Table 2.7. In each case, the value of EH(W) is obtained by subtracting the functional term RTlnQ/nF from the standard potential. Table 2.7 Standard reduction potentials at 25°C for selected environmentally important redox couples. E (V)
E(W) (V)
∆G(W)/na (kJ/mol)
1.59
1.18
–113.5
1.22
0.81
–78.3
1.24
0.74
–71.4
0.52b
–50.2b
0.83
0.42
–40.5
NO3–+ 10H+ + 8 e– = NH4+ + 3H2O FeOOH(s) + HCO3– + 2H+ + e– = FeCO3(s) + 2H2O Pyruvate + 2H+ + 2e– = lactate SO –2 + 9H+ + 8e– = HS– + 4H O
0.88
0.36
–34.7
S(s) + 2H+ + 2e– = H2S(g) CO2(g) + 8H+ + 8e– = CH4(g) + 2H2O CO2 + HCO3– + H+ + e– = CH3COO– + 3H2O 2H+ + 2e– = H
Half-reaction 2HOCL + 2H+ + 2e– = Cl + H O 2
2
O2(g) + 4H+ + 4 e– = 2H2O 2NO3– + 12H+ + 10 e– = N2 + 6H2O Cl + 2e– = 2Cl– 2
MnO2(s) + HCO3– + 3H + 2e– = MnCO3(s) + 2H2O NO – + 2H+ + 2 e– = NO – + H O 3
2
4
2
2
2
6CO2 + 24 H+ + 24 e– = C6H12O6 + 6H2O a
Based on [HCO3–] = 10 M. Number of moles transferred.
b
–3
1.40
–0.05b
4.6b
–0.19
18.3
0.25
–0.22
21.3
0.17
–0.24
23.5
0.17
–0.25
23.5
–0.29
27.65
0.00
–0.41
39.6
–0.01
–0.43
41.0
47
48
Biofilm Reactors
5.11 Example 2—Calculation of Electrode Reduction Potentials and ∆G for Half-Reactions Determine the electrode potential for the reduction of NO3– to NO2– at temperatures of 15 and 25 °C and pH values of 7 and 10.
5.12 Solution The solution can be obtained as follows:
(1) The half-reaction and standard electrode potential are NO3– + 2H+ + 2 e– = NO2– + H2O EH(W) = 0.83
(2) Determine the electrode potential at 15°C. pH = 7 NO −2 }{H 2 O} { RT EH(W) = 0.83 − ln 2 nF {NO −3 }{H+ }
For equal molar concentrations of NO3– and NO2–, that is {NO3–} = {NO2–}, and remembering that the activity of water is 1.0,
EH(W) = 0.83 −
EH(W) = 0.83 −
pH = 10
RT 1 RT ln = 0.83 − In (107)2 2 + nF nF H
(8.314J / mol ⋅ K)(285K) ln 1014= 0.83 − 0.40 = 0.43 V (2)(9.649 × 104 J / mol ⋅ V) EH(W) = 0.83 −
EH(W) = 0.83 −
RT ln(1010)2 nF
(8.314J / mol ⋅ K)(285K) ln 1020 = 0.83 − 0.57 = 0.26 V (2)(9.649 × 104 J / mol ⋅ V)
(3) Determine the electrode potential at 25 °C.
pH = 7
EH(W) = 0.83 −
(8.314J / mol ⋅ K)(285K) ln 1014 = 0.83 − 0.41 = 0.42 V (2)(9.649 × 104 J / mol ⋅ V)
Biology of Fixed-Growth Process
pH = 10
EH(W) = 0.83 −
(8.314J / mol ⋅ K)(285K) ln 1020 = 0.83 − 0.59 = 0.24 V (2)(9.649 × 104 J / mol ⋅ V)
Thus, the electrode potential is not very sensitive to the temperature value (within the typical environmental operating range). However, the potential value is quite sensitive to the operating pH. A sense of the relative attractiveness of electron acceptors in biochemical reactions can be attained by comparing the free energy change of the overall redox equations. An example is the oxidation of glucose (C6H12O6) using oxygen (O2) and NO3– as the electron acceptors. Determination of the free energy change is accomplished by application of the Nernst equation (eq 2.3) using the standard reduction potentials available in the literature. For the glucose –O2 and glucose NO3– reaction systems, the relevant half-reactions are as follows:
6CO2 + 24 H+ + 24 e– = C6H12O6 + 6H2O
(2.8)
O2(gas) + 4H+ + 4 e– = 2H2O
(2.9)
2NO3– + 12H+ + 10 e– = N2 + 6H2O
(2.10)
The free energy change for the two reaction systems is compared by writing the half-reactions on a per-electron basis, as follows: 1 1 1 CO2 + H+ + e– = C6H12O6 + H2O E(W) = − 0.43 (2.11) 4 24 4
1 1 O (gas) + H+ + e– = H2O E(W) = 0.81 4 2 2
(2.12)
1 6 1 3 NO3– + H+ + e– = N2 + H2O E(W) = 0.74 5 5 10 5
(2.13)
The ∆G values for the total reactions then are calculated, as follows: Glucose/O2
1 C H O + O2(gas) = CO2 + H2O 6 6 12 6
∆E(W) = E(W)reductant – E(W)oxidant = 0.81 − (−0.43) = 1.24 V ∆G(W) = -F∆E(W) = –119.6 kJ/mol
49
50
Biofilm Reactors
Glucose/NO3–
C6H12O6 + NO3– + H+ = CO2 + N2 + H2O
∆E(W) = E(W)reductant – E(W)oxidant = 0.74 − (−0.43) = 1.17 V
∆G(W) = –F∆E(W) = –112.9 kJ/mol
Oxygen is a more attractive electron acceptor than nitrate, on the basis of available energy from the reaction, and this is one reason that oxygen dominates among the range of electron acceptors used by bacteria.
5.13 Co-Metabolism Organic compounds that do not serve as growth substrates are sometimes broken down through a process commonly called co-metabolism or incidental metabolism. The biodegradation process typically is initiated through the action of an enzyme having little specificity, which typically attacks growth substrates. In some cases, carbon from the breakdown of materials co-metabolized has been shown to be incorporated to cells, which may indicate that products of the initial reactions may be growth substrates. However, often, the product of co-metabolism is a dead end, that is, another non-growth substrate. The most widely studied co-metabolic reactions are associated with the breakdown of chlorinated organic compounds and, in particular, the widely used solvent TCE. Aerobic biodegradation of TCE is initiated by methane monooxygenase enzymes used to break down methane (methanotrophic bacteria) (AlvarezCohen and McCarty, 1991); ammonia monooxygenase (Hyman et al., 1988), which catalyzes the conversion of ammonia to hydroxyl ammine in members of the genus Nitrosomonas; and phenol monooxygenase and toluene dioxygenase, which catalyze the first steps in the breakdown of phenol and toluene, respectively, in members of the genus Pseudomonas (Fan and Scow, 1993). Co-metabolism of TCE presents the following two interesting problems:
(1) TCE strongly competes for the active site with the growth substrate (see the Consortia section); and (2) The reaction product, TCE epoxide, apparently sorbs onto the oxygenase enzyme and destroys the catalytic activity.
Incorporation of co-metabolic processes to treatment systems presents real challenges.
Biology of Fixed-Growth Process
6.0 BACTERIAL GROWTH The objective of biological treatment is the development of a process that will transform contaminants in a water or wastewater into an acceptable form or state. However, from the viewpoint of the microorganisms used in treatment processes, the objective is simply to replicate themselves. The result of replication is an increase in total microbial mass, or mass concentration, and this increase is defined as growth. In some cases, the microbial objective is modified to surviving austerity until replication is possible again. Examples of austerity include dry and low-temperature periods in soil and the segments of biological wastewater treatment systems in which the primary organic substrates are exhausted. Bacterial replication, or growth, requires energy; carbon (to build the organic compounds making up the cell); and inorganic nutrients, such as nitrogen, phosphorus, sulfur, and iron, which are components of organic compounds or serve in other ways in the chemical reaction processes carried out within the cell. Heterotrophic metabolism, where organic compounds serve as both the energy source and the carbon source, is the most important type of metabolism in biological treatment and will be used as a model.
6.1 The Bacterial Growth Curve When bacteria are grown in a batch culture with the initial condition that nutrients are not limiting, a characteristic pattern of growth occurs, which is commonly divided into the six segments shown in Figure 2.6—lag, increasing growth, logarithmic growth, declining growth, stationary, and death. The bacterial growth curve shown in Figure 2.6 is representative of pure (i.e., single species) cultures only, but the concepts generally are applied to other systems in a modified form. In the experimental process of producing a growth curve, the number of cells is determined by sampling at selected time intervals and using standard microbial plate-count techniques to estimate the population. A similar curve can be generated by measuring the mass concentration of cells present, and, because each cell can be presumed to have approximately equal mass, the two curves should be proportional. The limiting nutrient typically is the energy source (an organic compound for heterotrophic species), but could be an inorganic nutrient, such as nitrogen or phosphorus. Typically, the cells used in growth-curve experiments are taken from cultures in the stationary phase, and a period of time, or lag, is required before growth is initiated. The lag can be eliminated by transferring cells from a culture in the logarithmic
51
Stationary
Decreasing Growth
Lag No
Log Growth
Co
Increasing Growth
Limiting Nutrient Conc., mg/L
Biofilm Reactors
Log10 Number of Cells
52
Death
Figure 2.6 Bacterial growth curve for a batch system in which nutrients initially are not limiting. As growth begins, the increase in cell number (or mass) is dependent only on the number (or mass) of cells present, and the system behaves in a firstorder autocatalytic manner.
growth phase. A short period of time, in which the growth rate changes from zero to the maximum value, exists (the increasing growth phase), which is probably the result of an uneven conversion of the population from non-growth to growth conditions. During the logarithmic growth phase, the rate-limiting variable is the number of cells present. Because the cells are a reaction product, the overall rate typically is observed to be first-order autocatalytic, with respect to the cell number or mass concentration. As the limiting nutrient concentration decreases to the point where the individual cells must compete for the material, the overall growth rate slows (decreasing growth), and, when the limiting nutrient concentration approaches zero, the culture begins to convert to a resting state, in which cell division essentially stops, and cell functions are maintained by catabolizing unnecessary materials and storage compounds. The unnecessary materials include transferase enzymes necessary for transporting nutrients across the cell membrane and internal metabolic enzymes
Biology of Fixed-Growth Process
used in processing externally derived nutrients. Often, the capsular layer increases in size, possibly to limit desiccation in dry soils. After a period of time extending from several hours to days, the culture begins to die. Upon death, cells typically breakup (lyse), and many cell components become nutrient sources for surviving cells.
6.2 Growth in Mixed Cultures Mixed microbial cultures typically are dominated by a few species of bacteria. However, a large number of microbial groups typically are present, and all of the groups present occupy ecological niches. In most cases, several species present will be able to at least partially metabolize organic compounds initially present. As breakdown progresses, other species may be able to metabolize partially degraded materials or excreted waste products of the first metabolizing groups. Higher forms of organisms will begin to graze on the heterotrophs as the population increases. An interlocking set of growth curves is produced that cannot adequately be described by cell counts of a limited number of species. Total mass concentration commonly is used to follow the process, but the values measured are the sum of all species present, and, as time increases, they increasingly represent the growth of secondary organisms. This interaction of microbial groups in mixed cultures is one reason that kinetic and stoichiometric parameters measured under one set of conditions often are difficult to extrapolate to other conditions.
6.3 Enrichment Cultures When mixed cultures are operated under constant conditions, either steady-state feed and physical environment or repeated identical cycles, species with the highest growth rates will have a competitive advantage and will gradually predominate. In some cases, the procedure results in cultures limited to one or two species. Such operating conditions are called enrichment cultures, and the technique is used in the laboratory to isolate and grow species having particular desired characteristics. Enrichment culture conditions often exist in industrial wastewater treatment because of the limited number of biodegradable compounds present, the high temperature, or the low pH of the wastewater. In biological water and wastewater treatment, enrichment culture principles are used to develop flocculant cultures for suspended-growth systems and polyphosphate-storing cultures for phosphate-removal systems and also to control the growth of filamentous bacteria.
53
54
Biofilm Reactors
6.4 Stability of Mixed Cultures The use of mixed cultures for water and wastewater treatment results in more stable process operation. In most treatment operations, characteristics of the influent stream are changing constantly. Flowrate, chemical constituents concentrations, and temperature change on a continuous basis. Such varying conditions help maintain the mixed culture, by providing environmental conditions in which a broad spectrum of bacterial species can compete. The principal advantages of maintaining mixed cultures are that a more complete breakdown of organic compounds present occurs and that changes in influent characteristics typically do not greatly affect effluent quality. Bio-oxidation by single species of bacteria often results in some compounds being left unoxidized. In many cases, certain branched aliphatic compounds or substituted rings are attacked by a limited number of bacterial species. An organic polymer may be broken down partially by several species in pure culture and completely broken down in mixed culture. Similarly, when influent characteristics change, we might expect different microbial species to have competitive advantages. For example, the predominant bacterial species present may change from summer to winter in municipal treatment plants or with the products being produced in an industrial operation. Maintaining mixed cultures allows the most competitive species for a given set of conditions to predominate in a matter of days.
6.5 Effects of Environmental Variables Environmental variables affecting bacterial growth include temperature, pH, chemicals in the water, and the presence of surfaces on which microbial films can be established. Temperature strongly affects the reaction rates; has minor, if any, effects on reaction stoichiometry (Flegal and Schroeder, 1976); and, under conditions where molecular diffusion is important, mildly affects the rate of transport of nutrients to the cells (Kehrberger et al., 1964). The relationship between temperature and reaction rate differs with microbial species, and, in mixed cultures, temperature changes may result in significant changes in predominant species. Temperature-growth rate relationships are discussed in greater detail in the following section. Bacteria typically function well within broad pH ranges. Most of the bacterial species commonly found in wastewater treatment processes grow between pH 6 and 9, but activity falls off rapidly outside of that range. Nitrifying bacteria grow best under slightly alkaline conditions, such as pH 8 to 9.5. The sulfur-oxidizing bacteria
Biology of Fixed-Growth Process
are quite acid-tolerant, and some species grow well at pH values as low as 1, but do not grow at all at pH values above 6. When the growth rate is reported as a function of pH (Grady et al., 1999), clear optimum pH values are rarely apparent, and the curves are virtually flat within the region of growth. The role of dissolved organic and inorganic chemicals as nutrients, energy sources, and toxins is discussed elsewhere in this chapter. Total solute concentration, typically approximated satisfactorily by the salinity of water, is of some significance, because many industrial wastes are quite saline, and because the discharge of treated wastewater to saline environments is common. Biological treatment of saline wastewaters may be affected by differing microbial sensitivities to salinity; that is, species predominance may be affected. In discharging treated wastewater to saline environments, bacterial survival may be related to salinity, but the available data are not adequate to suggest modification of discharge requirements for ocean versus freshwater conditions. Most bacterial species are able to adjust to broad ranges in salinity (e.g., from less than 100 mg/L to 30 000 to 34 000 mg/L in seawater) and osmotic pressures if changes are made incrementally. A few species of bacteria, known as halophiles, grow at concentrations as high as 360 000 mg/L (Niedhardt et al., 1990). Large, rapid decreases in salinity may result in the leaching of water from cells and damage to the cytoplasmic membrane. Large, rapid increases in salinity may result in the accumulation of water within cells to the point that they burst. In general, salinity is not a major factor in the design or operation of biological treatment processes.
7.0 BACTERIAL GROWTH KINETICS IN BIOFILMS Bacterial growth is the result of a large number of extra- and intracellular reactions that provide energy, carbon, and nutrients for the biosynthesis process. Design and operation of biological treatment processes are related strongly to the rate of bacterial growth, and, for this reason, discussion of bacterial growth kinetics is essential. However, bacterial growth theory was developed from experiments with pure cultures, while biological treatment processes are almost always composed of mixed cultures. Rates of growth and nutrient removal typically are measured using lumped or surrogate parameters, such as suspended or volatile solids, BOD, COD, or TOC, and global rates observed cannot be extrapolated or generalized. Even with this limitation, the application of rate process concepts is an essential component of biological process design and operation.
55
56
Biofilm Reactors
7.1 Rate of Bacterial Processes Rate expressions used to describe the removal of organic material, growth of the microbial population, and use of oxygen, the three terms of greatest importance in eq 2.1, typically are based on the modified Monod model given in eqs 2.14 through 2.16.
ro = −
kC X K +C
kC − kd X rg = − Yro − kd X = Y K +C
rO2 = ro + γ rg = ro − γ (Yro + kdX)
= ro(1 − γY) − γkdX
(2.14) (2.15)
(2.16)
Where ro = rate of removal of organic material (g/m3·d); rg = rate of production of new microbial mass (g/m3·d); rO2 = rate of oxygen use (g/m3·d); k = rate of removal coefficient (d–1); C = organic concentration, often measured as UBOD or COD (g/m3); X = microbial mass concentration measured as suspended solids or volatile suspended solids (g/m3); K = saturation coefficient (g UBOD/m3); Y = mass yield coefficient (g solids produced/g UBOD removed); kd = maintenance energy rate coefficient (d–1); and γ = ratio of UBOD removed to cell mass produced (g/g).
7.2 Note
C X, where µm is the maximum K +C specific growth rate or the maximum mass of cells produced per unit mass present per unit of time. This nomenclature is awkward from the process analysis viewpoint because of the way that the maintenance energy must be introduced. The solids production rate, rg, and oxygen uptake rate (OUR), rO2, are shown as functions of the organic removal rate, and more specifically the organic (UBOD) and microbial mass concentrations. These expressions (eqs 2.14 through 2.16) will be used to describe overall metabolism in all types of biological processes. The growth rate often is written as rg = µm
Biology of Fixed-Growth Process
Often, the specific rates, or rates per unit mass of microbial mass present, are reported rather than the overall rate. For example, the specific removal and growth rates are stated as follows:
Ro = Rg =
ro kC =− X K +C
rg X
=Y
kC − kd K +C
(2.17) (2.18)
In some commonly used biodegradation and growth models, rate expressions are written for two or more components of the organic mixture. For example, the UBOD may be divided into soluble and particulate portions, and separate expressions may be written for each component (Henze et al., 1995; Metcalf and Eddy, 2003). The ratio of UBOD removed to cell mass produced, γ, is based on chemical stoichiometry and empirical cell formulations. The value also can be referred to the theoretical BOD of the cells produced. The most commonly used empirical formula for cells is C5H7NO2, but a number of other formulas are in use (McCarty, 1965; Porges et al., 1953). A value of γ is estimated by calculating the stoichiometry of the oxidation of the empirical cell formulation, as shown in eqs 2.19 and 2.20.
C5H7NO2 + 5 O2 → 5 CO2 + NH3 + 2H2O γ=
5(32) = 1.42 g/g 113
(2.19) (2.20)
Other suggested empirical formulas result in similar values of γ. For example, the formula C60H87O23N12P has a theoretical UBOD of 1.39 g/g. It is important to remember that eqs 2.14, 2.15, and 2.16 are global, nonstructured, empirical models, which sum up the results of a large number of coupled reactions, including interphase transport from the liquid to the solid cell surface. The assumption that growth of new cell mass and uptake of oxygen are coupled directly to nutrient removal is not completely true. Organic material may be removed from the liquid by adsorption onto/into biofilms without immediate production of new cell material and without oxygen uptake (Dobbs et al., 1989). If the sorbed material is biodegradable, a fraction of the sorbed mass will show up later in time, as new cell mass and a corresponding oxygen uptake would result. These events are illustrated in Figure 2.7, and descriptions of these more complex phenomena are termed structured models.
57
Biofilm Reactors
Concentration, mg/L and Rate, mg/L-s
58
Total Organic Carbon mg/L
Cell Mass, mg/L
Oxygen Uptake Rate, mg/L-s
Time, min
Figure 2.7 Relationships between organic removal, cell mass production, and OUR.
As shown in Figure 2.7, organic carbon removal occurs more rapidly than the actual breakdown or degradation of the compounds. As a result, oxygen uptake remains above background levels for a substantial period following carbon removal. Following organic removal, the cell mass concentration may continue to increase somewhat, may be approximately constant (as shown in Figure 2.7), or may decrease slowly, as conversion of the externally stored organic material occurs. When stored organics are used completely, the OUR decreases to the “basal” or “endogenous” value, and cell mass begins to decrease, as cell components, such as ribosomes and unneeded enzymes, are broken down. The use of lumped parameters as measures of the organic concentration (UBOD and COD) and the microbial mass (suspended solids or VSS) in eqs 2.14, 2.15, and 2.16 generally is required because of the complexity of the organic mixtures and microbial populations present in most situations. Compounds are taken up in parallel rather than sequence, and a single microbial species can metabolize more than one type of compound simultaneously. A problem exists where a specific compound must be removed, particularly if the target compound is present at a low concentration. In such cases, removal of the BOD or COD to satisfactory levels may not result in satisfactory degradation of the target compound. In addition, the equations, in the
Biology of Fixed-Growth Process
form presented, do not include either mass transport limitations or consideration of the reactions or reaction sequences that are involved in the biological treatment process. Lumping the organic species present into a single concentration term generally is satisfactory. In most cases, it would be impossible to monitor individual organic contaminants, and, perhaps more importantly, the use of overall concentration parameters based on oxygen consumption (UBOD and COD) provide direct relationships to other parameters of importance, such as growth. Finally, in a given source, the contaminant makeup typically is relatively consistent, and surrogate parameters, such as UBOD, COD, and TOC, provide the necessary rate information. An argument similar to that for the use of overall parameters for organic concentration can be made for the use of an overall mass concentration for the microbial mass. The assumption is made that the actual cell mass concentration is proportional to the particulate filtered solids mass concentration (suspended solids or VSS) measured. This assumption would mean that the EPS-mass-to-cell-mass ratio was constant, for example. Although this and other similar assumptions are somewhat shaky, the models have had considerable utility, and laboratory and field measurements typically follow the patterns shown in Figure 2.7.
7.3 Physical and Chemical Changes in Biofilms Resulting from Growth The growth of bacterial cultures is defined by increases in cell number rather than cell size. In biofilms, daughter cells separate as EPS is produced, keeping the density approximately constant. Because growth is constrained latterly and by the support surface, depth increases as cells divide. Cells at the liquid or atmospheric surface have greater access to nutrients and oxygen. Deeper in the biofilm, cells may starve and die, or anoxic or anaerobic conditions may develop. Thus, gradients in oxygen and nutrient concentration and pH develop as biofilms become thicker (Lewandowski and Beyenal, 2003). In thick biofilms, gas formation at the support surface may result in detachment of the biofilm (Atkinson, 1974), and, where a liquid is flowing over the biofilm, as in trickling filters, weakened portions may be sloughed off.
7.4 Structured Models Inclusion of reaction sequences or reaction process sequences in reaction models is termed structuring. Flow diagrams for two structured models are shown in Figure 2.8. In both cases, a storage term is included, which accounts for non-stoichiometric
59
60
Biofilm Reactors
Organic materital
r1
→
Storage r2 w ithin → cell
B iodegradation and synthesis of new cell mass
a) Simple structured model of organic metabolism based on intracellular storage Organic material
r1
Intracellular metabolite pool
r
r2
3
Biodegradation and synthesis of new cell material
r4
Intracellular Storage
b) Structured model of organic metabolism based on maximum rates and intracellular storage. An assumption is made that the rate of transport into the cell can exceed the rate of conversion of organics. Materials not reacted are stored, presumably as glycogen or PHB. The stored materials are used during periods when the intracellular metabolite pool is low.
Figure 2.8 Structured models of metabolism include reactions or steps in the metabolic process that can be identified or separated: (a) the rate of metabolism is separated from the rate of organic removal from the liquid and (b) a somewhat more complex storage mechanism is shown, which could be used to account for several observed rates of growth and oxygen uptake.
differences in organic removal and OURs that have been observed. More complicated structured models have been proposed to describe the rates of individual cellular processes, such as protein synthesis. Because each rate term requires knowledge of additional rate coefficients, the use of structured models is difficult, even in research. Application of structured models in biological treatment processes composed of a wide range of microbial species and degrading a mixture of organics currently is not feasible.
7.5 Temperature Effects Removal and growth rates are affected strongly by temperature. Rate–temperature relationships typically follow the van’t Hoff-Arrhenius relationship up to approximately 40 °C (Flegal and Schroeder, 1976). In most cases, a modified form of this relationship is used to relate rate constants at a temperature, T, to those at a reference temperature, TR (typically 20 °C).
Biology of Fixed-Growth Process
kT = kTRθT − TR
(2.21)
Values of the temperature coefficient, θ, typically are in the range 1.02 to 1.06. Including temperature effects in biological treatment process design is critical. Most laboratory studies reported in the literature are run at 20 °C, but winter temperatures may drop to 5 °C in cold climates. Summer operating temperatures in municipal plants may reach 30 °C in hot climates, and some industrial wastewaters may approach 40 °C. Achieving satisfactory removals is a problem at low temperatures, unless the decrease in the value of the rate constant has been considered, while oxygen transfer may be limiting at high temperatures because of the decreased solubility and the increased removal rates. For a θ of 1.04, a 10 °C temperature differential from the reference condition results in an increase in the rate constant of 48%.
7.6 Example 3—Effect of Temperature on Organic Removal A batch biological reactor has an initial cell concentration of 30 mg/L and an initial organic concentration of 400 mg UBOD/L. Oxygen and inorganic nutrients are present in excess throughout the reaction period. The rate and stoichiometric coefficients for the system are given below. Compare the performance of the system at 10, 20, and 30 °C, assuming that the maintenance energy requirement (characterized by -kdX) is negligible. Use a temperature coefficient, θ, of 1.02.
k20 °C = 4.0 d–1, K = 20 mg/L Y = 0.40
7.7 Solution The solution can be obtained as follows:
(1) Determine a relationship between the cell concentration and the change in BODU. Because the maintenance energy requirement is negligible, in this case,
∆X = –Y∆C Xt – X0 = –Y (Ct – C0) Xt = –Y (Ct – C0) + X0 = 0.4(400 mg/L – Ct) + 30 mg/L
(2) Write the mass-balance equation for the BODU of the batch reaction system. In − Out + Generation = Accumulation
61
Biofilm Reactors
0 - 0 + Vr0 = V
∫
C C0
t K +C = – k ∫ dt 0 C(Xo + YCo − YC )
CXo K Xo + YCo − YC 1 In In = − kt Co (Xo + YCo − YC ) Y Xo + YCo Xo
dC dt
dC kC =− (Y − (C0 − C )+ X0 ) dt K +C
(3) Determine the rate constant values at 10 and 30 °C
kT = K20 °CθT − 20 = 4.0 (1.02T − 20)
k10 °C = 3.28
k30 °C = 4.88
(4) The equation can be solved and tabulated and plotted for the three temperature values (Figure 2.9 and Table 2.8). 500
200
400 300 200 10°C
100 0 0.0
30°C
150 SS, mg/L
BOD, mg/L
62
30°C
0.2
0.4
0.6
0.8
Time, days
20°C
1.0
20°C 10°C
100
50 0
1.2
0.0
0.2
0.4
0.6
0.8
1.0
1.2
Time, days
Figure 2.9 Effect of temperature on organic removal rate and microbial growth in example 3. Initial BODU and suspended solids concentrations were 400 mg/L and 30 mg/L, respectively. The initial conditions provide for near-exponential growth because K << Co.
Biology of Fixed-Growth Process
Table 2.8 BODU and suspended solids concentrations for the three temperature values. Time (days)
BODU (mg/L)
Suspended solids (mg/L)
10°C
20°C
30°C
10°C
20°C
30°C
0
400
400
400
30
30
30
0.2
377
372
364
39
41
44
0.4
348
333
310
51
57
66
0.6
310
280
234
66
78
96
0.8
260
205
120
86
108
142
0.9
232
160
43
97
126
173
1.0
197
100
111
150
1.1
158
40
127
174
1.15
138
135
190
0.1
7.8 Inhibition and Toxicity Inhibition of microbial metabolism occurs in the presence of materials toxic to the microorganisms or when non-metabolizable materials present adhere to cell surfaces and block the attachment of substrates. Note that metals are toxic in the ionic form and that the oxidation state can be expected to affect the toxicity. Ammonia in the dissolved gas form is toxic to fish at very low concentrations (<0.5 mg/L, in most cases) and to microorganisms at concentrations that rarely occur in WWTPs. The effects of inhibitory substances on growth and removal rates typically are modeled by adding a term to the rate expressions, which results in a maximum removal rate occurring at a critical inhibitant concentration. The Haldane expression (Yu and Semprini, 2004), originally developed as a model for enzyme inhibition by the reaction substrate, often is used to describe rate inhibition that occurs when otherwise biodegradable compounds are present at high concentrations (Figure 2.10). kC 2 ro = − K + C + C Ki
where
i
X
= Haldane inhibition coefficient (mg/L).
(2.22)
63
Biofilm Reactors
3.5 3.0 Specific Removal Rate, d–1
64
Nonmetabolizable inhibitant k = 4 d–1 K = 30 mg/L K'i = 50 mg/L CSubstrate = 100 mg/L
2.5 2.0 1.5
Substrate Inhibition k = 4 d–1 K = 30 mg/L Ki = 50 mg/L
1.0 0.5 0
0
20
40
60
80
100
Concentration, mg/L
Figure 2.10 Effect of inhibitant concentration on specific removal rate for two conditions: (a) substrate inhibition by a metabolizable inhibitant, represented by eq 2.22, and (b) a nonmetabolizable inhibitant, such as a heavy metal, represented by eq 2.23.
The application of eq 2.22 results in modified forms of eqs 2.17 and 2.18. In cases where inhibition results from the presence of non-metabolizable compounds, such as heavy metals, the inhibition relationship can be expected to be inversely proportional to the inhibitant concentration.
kC K'i ro = − X K + C K'i + CT
Where
K’i = inhibition coefficient (mg/L) and
CT = inhibitant concentration (mg/L).
(2.23)
7.9 Mass-Transfer-Rate Limitations Mass-transfer-rate limitations have been studied by a number of researchers (Atkinson, 1974; de Beer et al., 2004; Logan, 1993; Schroeder and Tchobanoglous, 1976; Swilley
Biology of Fixed-Growth Process
et al., 1964; Williamson and McCarty, 1976). Suggestions have been made that various rates are limited in both suspended- and attached-growth systems and that the limitations affect both process performance and microbial species makeup. Oxygen or one or more nutrients may be mass-transport-limited in the biofilms of fixed-growth processes. Such limitations result in changes in the type of metabolism (e.g., from O2 to NO3– as the terminal electron acceptor) and species predominance and removal and growth rates. A biofilm that is aerobic near the air interface and anaerobic near the supporting surface may have a significant pH gradient with depth.
8.0 KEY TRANSFORMATIONS IN BIOFILMS Chemical transformations in biofilms, as in all microbial processes, are associated with microbial growth. Sources of cell constituents are extracted from the liquid phase. Particulate matter is broken into soluble subunits through reactions catalyzed by extracellular enzymes, and soluble matter is transported across the cell membrane and converted into the necessary cell components in a complex series of enzymecatalyzed reactions. A parallel process exists for generating the energy required for cell functions. In nearly all fixed-growth processes used for wastewater treatment, chemical rather than photosynthetic energy is used, and the energy is released through redox reactions. Organic compound removal in biological processes occurs in a series of steps (Figure 2.11). The mechanism of nutrient transport to the biofilm–liquid interface differs somewhat with the type of unit. The first step, transport of the organic material to the biofilm surface, is brought about by turbulent transport in most reactor types. Only trickling filters are characterized by laminar flow in the liquid film. The mechanism of large molecule and particle attachment is not fully understood and probably involves sequential sorption and desorption. Biofilm surfaces are not smooth on the microscale, and the mechanisms of particle removal, such as interception and impaction, also may be significant. Smaller molecules pass into the spongelike biofilm structure until they come in contact with a bound enzyme or cell surface. A number of bacterial species typically are present, and the predominant species change with environmental conditions or the type of contaminants present. Changes in species predominance would be expected to take some time because of the low average growth rate imposed in most biological treatment processes and because the position of the bacteria in the biofilm would tend to make direct competition for substrate a slow process to develop.
65
66
Biofilm Reactors
Transport of particles to biofilm surface Organic particle
Attachment of particles to biofilm
Biofilm
Extracellular breakdown and intrabiofilm transport
Biofilm
Transport into cells and microbial degradation
Biofilm
Figure 2.11 Steps in the removal and breakdown of an organic particle in a biofilm.
The biofilm serves as a storage unit for extracellular enzymes and enzymes released from dead cells and as a concentrator for nutrients. Biological treatment processes do not provide rich growth conditions for bacteria and in fact are operated with just the opposite objective—to produce an environment with minimal concentrations of necessary growth nutrients. Bacteria growing under such conditions need to minimize energy expenditures made in gathering nutrients and maximize the energy channeled toward reproduction. Evidently, the biofilm structure is one response to these constraints.
8.1 Chemoheterotrophic Processes As noted above, in chemoheterotrophic processes, organic compounds serve as both energy and carbon sources for growth. Aerobic processes are of principal interest, because a broader range of compounds can be used, and the majority of compounds
Biology of Fixed-Growth Process
can be oxidized to CO2 and, therefore, completely stabilized. In all cases, new microbial cells are a product, and only a portion of the organics metabolized are oxidized.
8.2 Chemoautotrophic Processes When carbon dioxide or bicarbonate ion, HCO3–, serves as the carbon source and an inorganic ion (e.g., NH3, NO2–, H2S, S, and H2) serves as the energy source for growth, the metabolism is termed chemoautotrophic or simply autotrophic. The oxidation of nitrogen is important in wastewater treatment, because the reaction provides a method of eliminating ammonia toxicity to fish in receiving waters. Sulfide oxidation presents a serious problem in collection systems and treatment plants, because the products (H2SO3 and H2SO4) are extremely corrosive. Hydrogen serves as an energy source in some of the methane-producing reactions that produce methane in anaerobic sludge treatment processes.
8.3 Biology of Nitrogen Transformations Nitrogen exists in oxidation states from −3 to +5, with the most common forms found in wastewater being nitrite (NO2–) and nitrate (NO3–). Cellular nitrogen is entirely in the organic (the majority of compounds can be oxidized to CO2 and, therefore, completely stabilized −3 oxidation state) form. Ammonium is used directly in the growth process, while oxidized forms of nitrogen must be reduced from the +3 or +5 oxidation states using energy supplied by heterotrophic or autotrophic redox reactions in a process referred to as assimilatory nitrate reduction. Assimilatory nitrate reduction is virtually ubiquitous among microorganisms and, beyond resulting in small decreases in cell yield, because of the energy requirement, has little effect on processes.
8.4 Denitrification Under oxygen-limited or anaerobic conditions, many species of bacteria are able to use NO3– and NO2– as terminal electron acceptors, a process referred to as dissimilatory metabolism. Nitrate is reduced to N2 via NO2–, nitric oxide (NO), and nitrous oxide (N2O). This is a beneficial process in wastewater treatment, because it results in an innocuous end product, whereas both NO and N2O are greenhouse gases, and their accumulation is undesirable. The reductase enzymes are repressed at oxygen concentrations greater than 2.5 mg/L, yet, at low concentrations of oxygen (tenths of mg/L), they are only inhibited (Rittman and McCarty, 2001). As a result, it is possible for
67
68
Biofilm Reactors
enitrification to occur, even when residual oxygen is present. Biofilms particularly are suited to supporting multiple types of respiration because of their heterogenous structure.
8.5 Aerobic Nitrification The most important autotrophic bacteria in biological treatment systems are the nitrifiers—those organisms that oxidize NH3 and NO2–. Reduced forms of nitrogen are a source of oxygen demand in water, as shown in eqs 2.24 and 2.25.
NH4+ +
3 O2 → NO2– + 2 H+ + H2O 2
(2.24)
NO2– +
1 O2 → NO3– 2
(2.25)
Equations 2.24 and 2.25 are not completely correct, because carbon dioxide consumption and cell production are not included. Because very little energy is produced from the oxidation of NH3 and NO2–, and production of new cell material from CO2 requires a relatively large amount of energy, the cell mass yield per unit mass of nitrogen oxidized is small (typically approximately 0.05 g cells/g N). Estimates of oxygen requirements typically are based on the above equations. Thus, when nitrification occurs, approximately 4.57 g O2 must be supplied per gram of nitrogen oxidized. Domestic wastewaters typically contain 30 to 50 g/m3 of total Kjeldahl nitrogen (TKN), which includes organic nitrogen, NH3, and NH4+. Biodegradation of nitrogen-containing organic compounds results in release of the nitrogen as NH3. Thus, for the purpose of estimating oxygen demand, organic nitrogen can be treated as ammonia-nitrogen. Therefore, complete oxidation of TKN (nitrogen in the −3 oxidation state) in domestic wastewater will result in an oxygen demand of 130 to 190 g/m3. Estimates of the complete stoichiometry of the nitrification reactions have been made using “reasonable” values for the cell yield coefficients (Metcalf and Eddy, 2003); however, supporting data are difficult to obtain. Typical expressions are given in eqs 2.26 and 2.27. 55 NH4+ + 76 O2 + 109 HCO3– → C5H7NO2 + 54 NO2– + 57 H2O + 104 H2CO3
(2.26)
400 NO2– + 195 O2 + NH4+ + 4 H2CO3 + HCO3– → C5H7NO2 + 3 H2O + 400 NO3–
(2.27)
An important feature to note is that, for every mole of ammonia oxidized, approximately 2 mol H+ are produced. This means that 2 mol alkalinity are destroyed in
Biology of Fixed-Growth Process
the process, and, in many cases, nitrification results in significant decreases in pH. Because most biological processes work best in the pH range 6 to 8.5, nitrification can result in decreased efficiency or even process failure, if care is not taken to control alkalinity. The yields predicted from eqs 2.23 and 2.24 are 0.15 and 0.02 g cells/g N, respectively. The nitrifying bacteria are divided into two groups—those that oxidize NH3 and those that oxidize NO3–. The most widely studied NH3-oxidizing bacteria are of the genus Nitrosomonas, but several other genera exist. Nitrosococcus spp. and Nitrosomonas spp. commonly are found in wastewater, and members of the genus Nitrosospira may be the most common in soil (MacDonald, 1978; Stephen et al., 1996). Nitrosomonas also has an anaerobic metabolism and can use dinitrogen tetroxide (N2O4), a dimer of NO2–, as a terminal electron acceptor. Activity is low under anoxic conditions. N. eutropha also is capable of simultaneous denitrification; that is, it uses NO 2– as a terminal electron acceptor at O2 concentrations below 0.8 mg/L. It is estimated to denitrify at least 10% of the converted ammonia (Lipschultz et al., 1981). During this process, NO and N2O are produced. Nonetheless, all of the NH3-oxidizing bacteria are classified as obligate aerobes, because the oxidation of ammonia via hydroxylamine appears to be the only source of reducing power for biosynthesis in these organisms. Nitrobacter and Nitrospira are believed to be the most common genera among the – NO2 -oxidizing autotrophs. At least some of the Nitrobacter species also can denitrify under anoxic conditions, by reducing NO3– to NO2–. In addition, species of Nitrobacter are capable of growing mixotrophically, using organic carbon as a carbon source and NO2– as an energy source and yielding higher growth rates than when they grow lithoautotrophically. Even heterotrophic metabolism is possible under both oxic and anoxic conditions. Such growth is slower than lithoautotrophic growth (Bock, 1976), but can yield higher cell densities (Schmidt et al., 2003). The importance of heterotrophic metabolism by the nitrifying bacteria for fixed-growth systems has not been established, but the rates of nitrification reported in biological treatment are considerably greater than those reported for Nitrobacter growing heterotrophically or mixotrophically in pure cultures. It is entirely feasible that Nitrobacter uses a range of different strategies in biofilms. Nitrification generally is modeled using the modified Monod expressions.
8.6 Anoxic Nitrification/Denitrification Nitrification with concomitant denitrification is carried out under anoxic conditions by bacteria unknown to exist until the late 1980s. The bacteria belong to several genera
69
70
Biofilm Reactors
of the order Planctomycetales and are referred to as anaerobic ammonium oxidizers, or anammox bacteria, for short. They have been found in over 30 freshwater and marine environments around the world (Op den Camp et al., 2006) Anammox bacteria use NH4+ as an energy source and CO2 as a carbon source; thus, the process is autotrophic. Both NO2– and NO3– can be used as electron acceptors, with N2 as a product. Anammox bacteria are unable to use oxygen and do not function at oxygen concentrations above approximately 0.5 g/m3. Growth rates and yields of anammox bacteria are very low, even compared with aerobic nitrifiers. However, the saturation (affinity) coefficients, KSNH4+, are less than 0.1 g/m3, resulting in operation at maximum rates at very low NH4+ concentrations. Anammox bacteria are believed to be responsible for over 50% of the nitrogen transformations in the oceans and for most of the N2 in the Earth’s atmosphere. The late discovery of the anammox bacteria is explained partially by the fact that the organisms do not grow under conventional laboratory culturing conditions. Nitrogen transformations that could not be explained by the concentrations of known denitrifiers led to the search for unidentified groups using molecular biological techniques. Anoxic nitrification/denitrification can be carried out in wastewater treatment, in conjunction with organic oxidation, by providing aerobic and anoxic zones spatially (plug-flow) or temporally (sequencing batch operation) (Strous et al., 1997). Aerobic nitrification occurs in the aerobic zones, providing the NO2– necessary for anammox in the anoxic zones. A stoichiometric expression for the anammox nitrification/denitrification process is given below (Strous et al., 1998).
NH +4 + 1.32 NO 2− + 0.066 HCO3− + 0.13 H + →
1.02 N 2 + 0.26 NO3− + 0.066 CH 2 O0.5 N 0.15 + 2.03 H 2 0
(2.28)
The term CH2O0.5N0.15 is an empirical formula for cell products. Note that the predicted cell yield is 0.11 g cells/g N oxidized. Domestic wastewaters have relatively low concentrations of ammonium and organic nitrogen, and maintaining an anammox population in a conventional treatment process is difficult. Application of anammox to industrial wastewaters containing high concentrations of ammonia or urine streams separated from domestic wastewater is promising.
8.7 Biological Phosphorus Removal Biological phosphorus removal provides an excellent example of the relationships that can be developed in microbial consortia treating wastewater. Several uncultured
Biology of Fixed-Growth Process
heterotrophic bacteria are capable of producing storage materials in the form of polyphosphates when volatile fatty acids (VFAs) are present in the feed and maintaining 2 to 5 times higher levels of phosphorus in the cell than typically are present in the biomass. Candidatus Accumulibacter phosphatis or Rhodocyclus-related bacteria have been found in several enriched laboratory-scale reactors and also in full-scale plants (Oehmen et al., 2007). Other organisms appear to be involved in enhanced biological phosphorus removal (EBPR), including Actinobacteria (Kong et al., 2005). Polyphosphateaccumulating organisms use this material as an energy source when exogenous terminal electron acceptors are unavailable. Polyphosphate use does not occur unless the fluid is devoid of oxygen, nitrate, and nitrite. The presence of sulfate probably makes little difference, because sulfate-reducing organisms do not store polyphosphate and do not seem to compete with polyphosphate-storing bacteria under the conditions that occur in biological treatment. When full anaerobic conditions exist and bacteria with stored polyphosphate are present, the stored polyphosphate is hydrolyzed, and the energy released is used by the cells to store organic material, principally as PHB (Chiesa, 1982). The orthophosphate produced is released into the liquid. If the cells are then transferred into an aerobic or anoxic environment, the stored PHB is used as an energy and carbon source for growth and polyphosphate storage. Because a net increase in cell mass occurs as a result of the process, a net uptake of phosphorus also occurs. Removal of phosphorus from the system then can be achieved by wasting the cells produced. A competing group of organisms, the glycogen-accumulating organisms, also is capable of taking up VFA under anaerobic conditions, but without accumulating polyphosphate under aerobic conditions. The EBPR is used worldwide, and there are several processes that successfully have integrated EBPR (Oehmen at al., 2007).
8.8 Sulfide and Sulfur Oxidation Chemolithoautotrophic sulfur-oxidizing bacteria exist in many different groups of prokaryotes and include acidophiles (optimum pH <6) and neutrophiles (optimum pH 7 to 8). Acidophiles play an important role in acidic metal leaching processes, and neutrophiles tend to dominate in wastewater treatment processes. In addition, there are sulfur-oxidizing bacteria, which thrive at pH values above 9 (Sorokin et al., 2006).
8.9 Hydrogen Oxidation Hydrogen is a source of energy, and reductant and hydrogen-oxidizing bacteria are a fairly diverse group (Schwartz and Friedrich, 2006). Nearly all of the hydrogen
71
72
Biofilm Reactors
oxidizers also are able to metabolize simple organic compounds, and their taxonomic characteristics would place them in a variety of chemoheterotrophic genera. Molecular hydrogen is not a common product in aerobic environments; therefore, the hydrogen oxidizers are not major players in aerobic biological treatment. Autotrophic denitrification of drinking water can be accomplished with biofilms using hydrogen as an electron donor, either NO3– or NO2– as an electron acceptor, and CO2 as a carbon source. Hydrogen also is a key component of anaerobic metabolism in methanegenerating Archaea called methanogens and in anoxygenic phototrophs. Finally, hydrogen production allows cells to release excess reductant produced during fermentative metabolism.
9.0 FEATURES OF MICROBIAL COMMUNITIES IN BIOFILMS Bacteria most often are studied in pure cultures, but biological treatment processes use bacterial communities where species work together. This situation presents problems in translation of information gathered in bacterial research into applications in biological treatment problems, because it must be assumed that individual species behave differently as members of a consortium than in pure cultures. For example, the micro-environment surrounding a bacterium in a biofilm is affected by the activities of neighboring cells. The local oxygen concentration or tension may be low, although the average concentration in the medium is relatively high. In many cases, low oxygen concentrations result in the production of partially oxidized metabolites, such as organic acids, which are used by other species of bacteria or allow establishment of micro-aerophilic species, which would not be competitive at a higher oxygen concentration. Similar situations occur for local pH concentration effects. A number of important biological treatment processes are dependent on the activities of bacterial consortia consisting of different species or strains. Among these processes are nitrification and phosphorus removal (where acid-fermenting organisms provide substrate for the polyphosphate-storing organisms) and methane fermentation (in which acid and hydrogen fermenters produce substrate for the methane fermenters, and the methane fermenters remove compounds that would inhibit growth of the acid fermenters). In addition, many organic removal processes involve multiple bacterial strains or species where each may only be able to execute certain enzymatic steps in the degradation or transformation of a specific substrate.
Biology of Fixed-Growth Process
Microbial communities in fixed films (biofilms) and suspended systems used to be considered a black box, with respect to process engineering. In this line of thinking, there is sufficient microbial functional redundancy in a given community to lead to stable process performance (Briones and Raskin, 2003; Curtis and Sloan, 2006; Rittman and McCarty, 2001), such as COD removal, nitrification, and others. Curtis et al. (2006) further illustrated this concept by relating functional redundancy directly to diversity, where a more specialized function (e.g., nitrification) involves a less diverse pool of microbes or metacommunity than that associated with a less specialized task (e.g., simple carbohydrate breakdown). However, a long-term study revealed that stable biological treatment performance does not necessarily correlate to stable community dynamics (Fernandez et al., 1999). The relationship between microbial community structure and performance characteristics in fixed-film systems is not well-understood (Wuertz et al., 2004). What is known is that microbial community dynamics are reproducible in laboratory-scale reactors for at least 3 months, when operational parameters are kept unchanged (Falk et al., 2009). Advances in molecular microbial ecology and environmental biotechnology have opened the door for a more systems-based approach to the study of microbial consortia (Raes and Bork, 2008). It is known that many bacterial species can communicate via synthesis, release, and detection of diffusible signal molecules. They do so to monitor their own population density, in a process referred to as quorum sensing (Ryan and Dow, 2008), and thus modulate the level of expression of subsets of genes, such as those controlling polymer secretion (Nadell et al., 2008). Using pure culture biofilms, it has been shown that quorum sensing can influence the development and physical structure of biofilms. Bacteria also are capable of eavesdropping on signaling that occurs in their immediate environment. Such interspecies signaling is likely to play a role in fixed-film applications. Microbial consortia now can be studied using metagenomic approaches, even when it is not possible to cultivate individual members (Steele and Streit, 2005). Metagenomics refers to the study of mixed microbial populations from a specific habitat at the DNA level (Riesenfeld et al., 2004) and is made possible by the ability of researchers to clone large DNA fragments from an environmental sample and rapidly sequence the DNA. Increased knowledge about metabolic capacities at the genetic level, about the way intracellular communication organizes function in microbial consortia, and about natural fluctuations in microbial communities is expected to open the door to engineering microbial consortia for the optimization of fixed-growth
73
74
Biofilm Reactors
processes. In the future, biofilms may be engineered as synthetic consortia, with specific metabolic properties, and monitored with high-throughput molecular screening methods using inexpensive gene-chip-based technology.
10.0 REFERENCES Alvarez-Cohen, L.; McCarty, P. L. (1991) Effects of Toxicity, Aeration, and Reductant Supply on Trichloroethylene Transformation by a Mixed Methanotrophic Culture. Appl. Environ. Microbiol., 57, 228–235. Atkinson, B. (1974) Biochemical Reaction Engineering; Pion Press: London, United Kingdom. Aust, S.; Fernando, T.; Brock, B.; Tuisel, H.; Bumpus, J. (1988) Biological Treatment of Hazardous Wastes by Phanerochaete Chrysoporium. Proceedings of the Conference on Biotechnology Applications in Hazardous Waste Treatment, Longboat Key Florida, Oct 30–Nov 4, Lewandowski, G., Baltzis, B., Armenante, P. (Eds.); Engineering Foundation: New York. Bock, E. (1976) Growth of Nitrobacter in Presence of Organic Matter: 2. Chemoorganic Growth of Nitrobacter agilis. Arch. Microbiol., 108, 305–312. Briones, A.; Raskin, L. (2003) Diversity and Dynamics of Microbial Communities in Engineered Environments and Their Implications for Process Stability. Curr. Opin. Biotechnol., 14 (3), 270–276. Chiesa, S. C. (1982) Growth and Control of Filamentous Microbes in Activated Sludge. Ph.D. Dissertation, University of Notre Dame, Notre Dame, Indiana. Curtis, T. P.; Head, I. M.; Lunn, M.; Woodcock, S.; Schloss, P. D.; Sloan, W. T. (2006) What is the Extent of Prokaryotic Diversity? Phil. Trans. R. Soc. B, 361, 2023–2037. Curtis, T. P.; Sloan, W. T. (2006) Towards the Design of Diversity: Stochastic Models for Community Assembly in Wastewater Treatment Plants. Water Sci. Technol., 54 (1), 227–236. de Beer, D.; Stoudley, P.; Roe, F.; Lewandowski, Z. (2004) Effects of Biofilm Structure on Oxygen Distribution and Mass Transport. Biotechnol. Bioeng., 43, 1132–1138.
Biology of Fixed-Growth Process
Dobbs, R. A.; Wang, L. P.; Govind, R. (1989) Sorption of Toxic Organic Compounds on Waste Water Solids—Correlation with Fundamental Properties. Environ. Sci. Technol., 23, 1092–1097. Enright, A. M.; Collins, G.; O’Flaherty, V. (2007) Low-Temperature Anaerobic Biological Treatment of Toluene-Containing Wastewater. Water Res.: 41, 1465–1472. Evans, W. C.; Fuchs, G. (1988) Anaerobic Degradation of Aromatic Compounds. Annual Review of Microbiology, Ornston, L. N., Balows, A., Baumann, P. (Eds.); Annual Reviews, Inc.: Palo Alto, California. Falk, M. W.; Song, K. G.; Matiasek, M. G.; Wuertz, S. (2009) Microbial Community Dynamics in Replicate Membrane Bioreactors—Natural Reproducible Fluctuations. Water Res., 43, 842–852. Fan, S.; Scow, K. M. (1993) Biodegradation of Trichloroethylene and Toluene by Indigenous Microbial Populations in Soil. Appl. Environ. Micriobiol., 59, 1911–1918. Fernandez, A.; Huang, S. Y.; Seston, S.; Xing, J.; Hickey, R.; Criddle, C.; Tiedje, J. (1999) How Stable is Stable? Function Versus Community Composition. Appl. Environ. Microbiol., 65 (8), 3697–3704. Flegal, T. M.; Schroeder, E. D. (1976) Temperature Effects on BOD Stoichiometry and Oxygen Uptake Rate. J. Water Pollut. Control Fed., 49, 2700–2707. Fuhs, G. W.; Chen, M. (1975) Microbiological Basis of Phosphate Removal in the Activated Sludge Process for the Treatment of Wastewater. Microb. Ecol., 2, 119–138. Grady, C. P. L., Jr.; Daigger, G. T.; Lim, H. C. (1999) Biological Wastewater Treatment, 2nd ed.; Marcel Dekker, Inc.: New York. Hackett, W. F.; Connors, W. J.; Kirk, T. K.; Zeikus, J. G. (1977) Microbial Decomposition of Synthetic 14C-Labeled Lignins in Nature: Lignin Biodegradation in a Variety of Natural Materials. Appl. Environ. Microbiol., 33, 43–51. Hall-Stoodley, L.; Costerton, J. W.; Stoodley, P. (2004) Bacterial Biofilms: From the Natural Environment to Infectious Diseases. Nat. Rev. Microbiol., 2, 95–108.
75
76
Biofilm Reactors
Henze, M.; Gujer, W.; Mino, T.; Matsuo, T.; Wentzel, M. C.; Marais, G. v. R. (1995) Activated Sludge Model No. 2, IAWQ Scientific and Technical Reports, No. 3; International Association for Water Quality: London, United Kingdom. Hyman, M. R.; Murton, I. B.; Arp, D. J. (1988) Interaction of Ammonia Monooxygenase from Nitrosomonas europea with Alkanes, Alkenes, and Alkynes. Appl. Environ. Microbiol., 54, 3187–3188. Ingraham, J. L.; Maaloe, O.; Neidhardt, F. C. (1983) Growth of the Bacterial Cell; Sinauer and Associates, Inc.: Sunderland, Massachusetts. Kehrberger, G. J.; Norman, J. D.; Schroeder, E. D.; Busch, A. W. (1964) BOD Progression in Soluble Substrates. VII. Temperature Effects. Proceedings of the 19th Purdue Industrial Waste Conference, West Lafayette, Indiana, May 5–7; Purdue University: West Lafayette, Indiana. Kong, Y. H.; Nielsen, J. L.; Nielsen, P. H. (2005) Identity and Ecophysiology of Uncultured Actinobacterial Polyphosphate-Accumulating Organisms in Full-Scale Enhanced Biological Phosphorus Removal Plants. Appl. Environ. Microbiol., 71, 4076–4085. Lengeler, J. W. ; Drews, G. ; Schlegel, H. G. (Eds.) Biology of the Prokaryotes (1999) Thieme Verlag: Stuttgart, Germany. Levin, G. V.; Shapiro, J. (1967) Metabolic Uptake of Phosphorus by Wastewater Organisms. J. Water Pollut. Control Fed., 37, 800–821. Lewandowski, Z.; Beyenal, H. (2003) Mass Transport in Heterogeneous Biofilms. In Biofilms in Wastewater Treatment: An Interdisciplinary Approach, Wuertz, S., Bishop, P. L., Wilderer, P. A. (Eds.); IWA Press: London, United Kingdom. Lipschultz, F.; Zafiriou, O. C.; Wofsky, S. C.; McElroy, M. B.; Valois, F.W.; Watson, S. W. (1981) Production of NO and N2O by Soil Nitrifying Bacteria. Nature, 294, 641–643. Logan, B. E. (1993) Oxygen Transfer in Trickling Filters. J. Environ. Eng., 119, 1059–1076. MacDonald, R. M. (1978) Population Dynamics of the Nitrifying Bacterium Nitrosolubus in Soil. J. Appl. Ecol., 16, 529–535. Madigan, M. T.; Martinko, J. M.; Parker, J. (2003) Brock Biology of Microorganisms, 9th ed.; Prentice-Hall: Englewood Cliffs, New Jersey.
Biology of Fixed-Growth Process
Mattick, J. S. (2002) Type IV Pili and Twitching Motility. Annu. Rev, Microbiol., 56, 289–314. McCarty, P. L. (1965) Thermodynamics of Biological Synthesis and Growth. Proceedings of the 2nd International Conference on Water Pollution Research; New York, 169. Metcalf and Eddy, Inc. (2003) Wastewater Engineering: Treatment and Reuse, Tchobanoglous, G., Burton, F. L., Stensel, H. D. (Eds.); McGraw-Hill: New York. Nadell, C. D.; Xavier, J. B.; Levin, S. A.; Foster, K. R. (2008) The Evolution of Quorum Sensing in Bacterial Biofilms. PLoS Biol., 6, 0171–0179. Neidhardt, F. C.; Ingraham, J. L.; Schaechter, M. (1990) Physiology of the Bacterial Cell: A Molecular Approach; Sinauer Associates, Inc.: Sunderland, Massachusetts. Nielsen. P. H.; Jahn, A. (1999) Extraction of EPS. In Microbial Extracellular Polymeric Substances, Wingender, J., Neu, T. R., Flemming, H.-C. (Eds.); Springer: Berlin, Germany, 49–72. Oehmen, A.; Lemos, P. C.; Carvalho, G.; Yuan, Z. G.; Keller, J.; Blackall, L. L.; Reis, M. A. M. (2007) Advances in Enhanced Biological Phosphorus Removal: From Micro to Macro Scale. Water Res., 41, 2271–2300. Op den Camp, H. J. M.; Kartal, B.; Guven, D.; van Niftrik, L.; Haaijer, S. C. M.; van der Star, W. R. L.; van de Pas-Schoonen, K. T.; Cabezas, A.; Ying, Z.; Schmid, M. C. (2006) Global Impact and Application of the Anaerobic AmmoniumOxidizing (Anammox) Bacteria. Biochem. Soc. Trans., 34, 174–178. Porges, N.; Jaiswicz, L.; Hoover, S. R. (1953) Biological Oxidation of Dairy Waste, VII. Proceedings of the 24th Purdue Industrial Waste Conference, West Lafayette, Indiana, May 6–8; Purdue University: West Lafayette, Indiana. Raes, J.; Bork, P. (2008) Molecular Eco-Systems Biology: Towards an Understanding of Community Function. Nat. Rev. Microbiol., 6, 693–699. Rajal, V. B.; McSwain, B. S.; Thompson, D. E.; Leutenegger, C. M.; Kildare, B.; Wuertz, S. (2007) Validation of Hollow Fiber Ultrafiltration and Real Time PCR Using Bacteriophage PP7 as Surrogate for the Quantification of Viruses from Water Samples. Water Res., 41, 1411–1422.
77
78
Biofilm Reactors
Rajal, V. B.; McSwain, B. S.; Thompson, D. E.; Leutenegger, C. M.; Wuertz, S. (2007) Molecular Quantitative Analysis of Human Viruses in California Storm Water. Water Res., 41, 4287–4298. Reineke, W.; Knackmuss, H. J. (1988) Microbial Degradation of Haloaromatics. Annu. Rev. Microbiol., 42, 263–287. Riesenfeld, C. S.; Schloss, P. D.; Handelsman, J. (2004) Metagenomics: Genomic Analysis of Microbial Communities. Ann. Rev. Genet., 38, 525–552. Rittman, B. E.; McCarty, P. L. (2001) Environmental Biotechnology: Principles and Applications; McGraw-Hill: New York. Ryan, R. P.; Dow, J. M. (2008) Diffusible Signals and Interspecies Communication in Bacteria. Microbiology, 154, 1845–1858. Schmidt, I.; Sliekers, O.; Schmid, M.; Bock, E.; Fuerst, J.; Kuenen, J. G.; Jetten, M. S. M.; Strous, M. (2003) New Concepts of Microbial Treatment Processes for the Nitrogen Removal in Wastewater. FEMS Microbiol. Rev., 27, 481–492. Schroeder, E. D. (2002) Trends in Application of Gas-Phase Bioreactors. Rev. Environ Sci. Biotechnol., 1, 65–74. Schroeder, E. D.; Eweis, J. B.; Chang, D. P. Y.; Veir, J. K. (2000) Biodegradation of Recalcitrant Compounds. Water Air Soil Pollut., 123, 133–146. Schroeder, E. D.; Tchobanoglous, G. (1976) Mass Transfer Limitations in Trickling Filters. J. Water Pollut. Control Fed., 48, 771–775. Schroeder, E. D.; Wuertz, S. (2003) Bacteria. In The Handbook of Water and Wastewater Microbiology, Mara, D., Horan, N. (Eds.); Elsevier: Amsterdam, Netherlands, 57–68. Serafim, L. S.; Lemos, P. C.; Levantesi, C.; Tandoi V.; Santos H.; Reis M. A. M. (2002) Methods for Detection and Visualization of Intracellular Polymers Stored by Polyphosphate-Accumulating Microorganisms. J. Microbiol. Meth., 51, 1–18. Schwartz, E.; Friedrich, B. (2006) The H 2-Metabolizing Prokaryotes. In The Prokaryotes: An Evolving Electronic Resource for the Microbiological Community, 3rd ed.; Springer: New York, 496–563. Shapiro, J.; Levin, G. V.; Zea, H. G. (1967) Anoxically Induced Release of Phosphate in Wastewater Treatment. J. Water Pollut. Control Fed., 39, 1810–1818.
Biology of Fixed-Growth Process
Singer, P. C.; Stumm, W. (1970) The Solubility of Ferrous Iron in CarbonateBearing Waters. J. Am. Water Works Assoc., 62, 198–202. Skraber, S.; Helmi, K.; Ferreol, M.; Gantzer, C.; Hoffmann, L.; Cauchie, H. M. (2007) Occurrence and Persistance of Bacterial and Viral Faecal Indicators in Wastewater Biofilms. Water Sci. Technol., 55 (8–9), 377–385. Sorokin, D. Y.; Banciu, H.; Robertson, L. A.; Kuenen, J. G. (2006) Haloalkaliphilic Sulfur-Oxidizing Bacteria. In The Prokaryotes: An Evolving Electronic Resource for the Microbiological Community, 3rd ed.; Springer: New York, 969–984. Spaeth, R.; Wuertz, S. (2000). Extraction and Quantification of Extracellular Polymeric Substances from Wastewaters. In Biofilms. Investigative Methods & Applications, Flemming, H.-C., Szewzyk, U., Griebe. T. (Eds.), Technomic Publishers: Lancaster, Pennsylvania, 51–68. Stanier, R. Y.; Ingraham, J. L.; Wheelis, M. L.; Painter, P. R. (1986) The Microbial World; Prentice-Hall: Englewood Cliffs, New Jersey. Steele, H. L.; Streit, W. R. (2005) Metagenomics: Advances in Ecology and Biotechnology. FEMS Microbiol. Lett., 247, 105–111. Stephen, J. R.; McCaig, A. E.; Smith, Z.; Prosser, J. L.; Embley, T. M. (1996) Molecular Diversity of Soil and Marine 16S rRNA Gene Sequences Related to β-Subgroup Ammonia-Oxidizing Bacteria. Appl. Environ. Microbiol., 62, 4147–4154. Steward, G. F.; Smith, D. C.; Azam, F. (1996) Abundance and Production of Bacteria and Viruses in the Bering and Chukchi Seas. Mar. Ecol. Prog. Ser., 131, 287–300. Strous, M.; Heijnen, J. J.; Kuenen, J. G.; Jetten, M. S. M. (1998) The Sequencing Batch Reactor as a Powerful Tool for the Study of Slowly Growing Anaerobic Ammonium-Oxidizing Microorganisms. Appl. Microbiol. Biotechnol., 50, 589–596. Strous, M.; Van Gerven, E.; Ping, Z.; Kuenen, J. G.; Jetten, M. S. M. (1997) Ammonium Removal from Concentrated Waste Streams with the Anaerobic Ammonium Oxidation (Anammox) Process in Different Reactor Configurations. Water Res., 31, 1955–1962. Swilley, E. L.; Bryant, J. O.; Busch, A. W. (1964) The Significance of Transport Phenomena in Biological Oxidation Processes. Proceedings of the 19th Purdue
79
80
Biofilm Reactors
Industrial Waste Conference, West Lafayette, Indiana, May 5–7; Purdue University: West Lafayette, Indiana. Szewzyk, U.; Szewzyk, R. ; Manz, W. ; Schleifer, K.-H. (2000) Microbiological Safety of Drinking Water. Annu. Rev. Microbiol., 54, 81–127. Venugopalan, V. P.; Kuehn, M.; Hausner, M.; Springael, D.; Wilderer, P. A.; Wuertz, S. (2005) Architecture of a Nascent Sphingomonas sp. Biofilm under Varied Hydrodynamic Conditions. Appl. Environ. Microbiol., 71, 2677–2686. Wilderer, P. A.; Bungartz, H.-J.; Lemmer, H.; Wagner, M.; Keller, J.; Wuertz, S. (2002) Modern Scientific Methods and Their Potential in Wastewater Science and Technology. Water Res., 36, 370–393. Williamson, K.; McCarty, P. L. (1976) A Model of Substrate Uptake by Bacterial Films. J. Water Pollut. Control Fed., 48, 9–24. Woertz, J. R.; Kinney, K.A.; McIntosh, N. D. P.; Szaniszlo, P. J. (2001) Removal of Toluene in a Vapor-Phase Bioreactor Containing a Strain of the Dimorphic Black Yeast Exophiala lecanii-corni. Biotechnol. Bioeng., 75, 550–558. Woertz, J. R.; Kinney, K. A.; Szaniszlo, P. J. (2001) A Fungal Vapor-Phase Bioreactor for the Removal of Nitric Oxide from Waste Gas Streams. J. Air Waste Manag. Assoc., 51, 895–902. Wuertz, S.; Okabe, S.; Hausner, M. (2004) Microbial Communities and Their Interactions in Biofilm Systems: An Overview. Water Sci. Technol., 49 (11–12), 327–336. Yu, S.; Semprini, L. (2004) Kinetics and Modeling of Reductive Dechlorination at High PCE and TCE Concentrations. Biotechnol. Bioeng., 88, 451–464.
Chapter 3
Trickling Filter and Combined Trickling Filter Suspended-Growth Process Design and Operation 1.0 INTRODUCTION
83
2.0 General Description
84
4.0 Ventilation and Air Supply Alternatives
100
2.1 Distribution System
84
4.1 Natural Draft
101
2.2 Biofilm Carriers
87
4.2 Mechanical Ventilation
102
2.3 Containment Structure 90 2.4 Underdrain System and Ventilation
5.0 Trickling Filter Process Models 103
90
2.5 Trickling Filter Pumping Stations: Influent and Recirculation 91
5.1 National Research Council
103
2.6 Hydraulic and Contaminant Loading
5.2 Galler and Gotaas
105
5.3 Kincannon and Stover 106
3.0 Process Flow Sheets and Bioreactor Configuration 3.1 Standard Process Flow Diagrams
92
93 93
5.4 Velz
107
5.5 Schulze
107
5.6 Germain
108
5.7 Eckenfelder
109
5.8 Chartered Institution of Water and Environmental Management 110
3.2 Bioreactor Classification 96 3.3 Hydraulic Application: Effect on Media Wetting, Flow Distribution, and Control 98
5.9 Logan Trickling Filter Model 81
111
(continued)
82
Biofilm Reactors
5.10 Selecting a Trickling Filter Model 112 5.11 Method for Combining Trickling Filter and Suspended-Growth Models 113 6.0 Process Design
115
6.1 Combined Carbon Oxidation and Nitrification
115
6.2 Nitrifying Trickling Filters
120
6.2.1 Gujer and Boller Nitrifying Trickling Filter Model 122 6.2.2 Okey and Albertson Nitrifying Trickling Filter Model 124 6.2.2.1 Application of the Gujer and Boller Model 126 6.2.2.2 Application of the Albertson and Okey Model 128 6.3 Temperature and Hydraulic Application Effects 131 7.0 Design Considerations 132 7.1 Distribution System
133
7.1.1 Hydraulic Drive Rotary Distributors 134
7.1.2 Electronic or Mechanical Drive Rotary Distributors 136 7.1.3 Optimizing Rotary Distributor Operation 138 7.2 Construction of Rotary Distributors 138 7.3 Trickling Filter Media Selection 139 7.3.1 Depth 141 7.3.2 Structural Integrity 142 7.4 Trickling Filter Pumping Station or Dosing Siphon 144 7.5 Control Mechanisms for Trickling Filter Macro Fauna 144 7.5.1 Operational Strategies and Facility Improvements for Macro Fauna Control 145 7.5.2 Spülkraft 147 7.5.3 Flooding 148 7.5.4 Chemical Treatment 149 7.5.5 Physical Control 152 7.6 Trickling Filter Startup 153 7.7 Combined Trickling Filter and Suspended-Growth Processes 155 7.7.1 Activated Biofilter 156 7.7.2 Trickling Filter/Solids Contact 158 (continued)
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
7.7.3 Roughing Filter/ Activated Sludge 162 7.7.4 Biofilter/Activated Sludge 162
7.7.5 Trickling Filter/ Activated Sludge 8.0 REFERENCES
162 163
1.0 INTRODUCTION Until the 1950s, trickling filter (TF) design protocol was scattered and empirical in nature. Then, during the 1950s and 1960s, the Dow Chemical Company (Midland, Michigan) began experimentation with modular plastic media (Bryan, 1955). Numerous trickling filter process studies were conducted during the same period (Eckenfelder, 1961; Galler and Gotaas, 1964; Germain, 1966; Schulze, 1960), which led to the development of generally accepted design criteria. After the U.S. Environmental Protection Agency (Washington, D.C.) issued its definition of secondary treatment standards in the early 1970s, the trickling filter process was regarded as being unable to consistently produce effluent water quality that met the published standards, in part, as a result of poor secondary clarifier design (Parker, 1999). Norris et al. (1982) described development of the trickling filter/solids contact process (TF/ SC) in response. The first full-scale TF/SC process included a rock-media trickling filter followed by a small aeration basin (receiving return sludge) and flocculator clarifier. The researchers demonstrated that wastewater treatment plant (WWTP) effluent water quality could be improved greatly by bioflocculation in the solids contact basin and improved secondary clarifier design. Combined trickling filter/suspended-growth (TF/SG) processes preceding the TF/SC process were designed with the suspended-growth reactor (SGR) primarily for oxidation. The modern trickling filter typically includes the following major components:
(1) Rotary distributors, with speed control; (2) Modular plastic biofilm carriers, or media (typically cross-flow [XF] media, unless the bioreactor is treating high-strength wastewater, which warrants the use of vertical-flow [VF] media); (3) A mechanical aeration system (which consists of air distribution piping and low-pressure fans); (4) Trickling filter effluent recirculation pumping station; and (5) Covers that aid with the uniform distribution of process air and foul air containment (for odor control).
83
84
Biofilm Reactors
Covers may be equipped with sprinklers that discharge in-plant recycle to cool plastic media during emergency shutdown. Trickling filter mechanics are poorly understood. Consequently, there is a general lack of mechanistic mathematical models and design approaches, and the design and operation of trickling filter and TF/SG processes is empirical or semi-empirical. Benefits inherent to the trickling filter process (when compared with activated sludge processes) include operational simplicity, resistance to toxic and shock loads, and low energy requirements. However, trickling filters are susceptible to nuisance conditions that are primarily caused by macrofauna. Process mechanical components dedicated to minimizing the accumulation of macrofauna, such as filter flies, worms, and snail (shells), are now standard. Unfortunately, information on the selection and design of these process components is fragmented and has been poorly documented. The TF/SC process is the most common TF/SG process. This chapter describes state-of-the art trickling filter and TF/SC process design and operation.
2.0 General Description The trickling filter is a three-phase biofilm reactor, with fixed carriers. Wastewater enters the bioreactor through a distribution system, trickles downward over the biofilm surface, and air moves upward or downward in the third phase, where it diffuses through the flowing liquid and into the biofilm. Trickling filter components generally include an influent water distribution system, containment structure, rock or plastic media, underdrain, and ventilation system. Figure 3.1 illustrates a trickling filter crosssection and these typical bioreactor components. Wastewater treatment using the trickling filter results in a net production of total suspended solids (TSS). Therefore, liquid–solid separation is required and typically is achieved with circular or rectangular secondary clarifiers. The trickling filter process generally includes an influent/ recirculation pumping station, trickling filter, and liquid–solid separation unit.
2.1 Distribution System Primary effluent (or screened and degritted wastewater—fine screens with a maximum 3-mm bar spacing or perforated plate orifice diameter—should be applied for preliminary treatment, if primary clarification is excluded from the process flow sheet) is either pumped or flows by gravity to the trickling filter distribution system. Essentially, there are two types of trickling filter distribution systems—fixed-nozzle and rotary distributors. Because their efficiency is poor, distribution with fixed nozzles should not be used (Harrison and Timpany, 1988). Rotary distributors may be
ROTARY DISTRIBUTOR DISTRIBUTOR ARM CONTAINMENT STRUCTURE
BIOFILM SUPPORT MEDIUM
85
FRP GRATING UNDERDRAIN
AIR DISTRIBUTION HEADER
INFLUENT
Figure 3.1 Typical trickling filter components and cross-section.
EFFLUENT
86
Biofilm Reactors
driven hydraulically or electrically. A properly designed rotary distribution system allows for effective media-wetting and the intermittent application of wastewater to biofilm carriers. The intermittent application of influent wastewater (i.e., typically primary effluent diluted with recirculated trickling filter effluent) allows the biofilm to have periods of “resting,” which primarily serves as a process aeration mechanism. Poor media-wetting may lead to dry pockets, ineffective treatment zones, and odor. Hydraulically driven rotary distributors have discharge orifices along the front and back of each arm. The distributor is driven forward by energy imparted by the influent stream. To the extent possible, distributor rotational speed is controlled by flow passing through the orifices, which are situated along the distributor arm face that points to the direction of rotation. These back-spray orifices, or reverse-thrusting jets, slow rotational speed, but the designer must determine the extent of speed control based on site-specific operating conditions and process hydraulics. An electrically driven or modern hydraulically driven rotary distributor may be required if reverse-thrusting jets are incapable of achieving the degree of speed control required to maintain the desired trickling filter dosing rate(s). A modern hydraulically driven rotary distributor is depicted in Figure 3.2. This system uses gates (controlled by variable-frequency drive [VFD]) to open or close distributor orifices and adjust
Figure 3.2 (Left) Hydraulically driven rotary distributors use variable frequency drive controlled gates that either open or close distributor orifices, which adjust with varying pumped flowrates to maintain a constant preset rotational speed; and (right) electrically driven rotary distributor (Photographs courtesy WesTech, Inc., Salt Lake City, Utah).
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
rotational speed. Figure 3.2 also depicts an electrically driven rotary distributor. The use of a VFD allows for the more precise control of distributor-arm location when stopping rotation. Electrically driven rotary distributors have motorized drive units that control distributor speed independent of the wastewater pumped flow.
2.2 Biofilm Carriers Ideal trickling filter media provides a high specific surface area, low cost, high durability, and porosity that is high enough to avoid clogging and promote ventilation (Metcalf & Eddy, 2003). Trickling filter media types include rock, random (synthetic), vertical-flow (synthetic), and cross-flow (synthetic). Both vertical- and cross-flow media are constructed with smooth and/or corrugated plastic sheets. Another commercially available synthetic media, although not commonly used, is vertically hanging plastic strips. Horizontal redwood or treated wooden slats also have been used, but generally are no longer considered viable because of high cost or limited supply. Modules of plastic sheets (i.e., self-supporting vertical- or cross-flow modules) are used almost exclusively for new and improved trickling filters, but several trickling filters with rock media exist and have proven capable of meeting treatment objectives, when properly designed and operated. Table 3.1 compares the characteristics of some trickling filter media types. The higher specific surface area and void space in modular synthetic media allows for higher hydraulic loading, enhanced oxygen transfer, and biofilm thickness control, compared with rock media. Rock media ideally has a 50-mm diameter, but may range in size. Rounded (river) rock helps mitigate some issues associated with rigid rock (slag) media. The slag rock contains crevices that can retain water and accumulate biomass. As a result of structural requirements associated with the large unit weight of the rock media, rock media are shallow compared with synthetic-media trickling filters and are more susceptible to excessive cooling. Trickling filter performance aside, the excessive cooling can subject media to freeze–thaw cycles. Water retained inside slag rock crevices may expand and sever rock fragments. This can result in fine material accumulation which, with retained biomass, is a primary contributor to rock-media trickling filter clogging (Grady et al., 1999). Generally, rock media is considered to have a low specific surface area, void space, and high unit weight. Although recirculation is common, the low void ratio in rock-media trickling filters limits hydraulic application rates. Excessive hydraulic application can result in ponding, limited oxygen transfer, and poor bioreactor performance. Performance of existing rock-media trickling filters sometimes may be improved by providing mechanical ventilation, solids contact channels, and/or deepened secondary clarifiers, which include energy-dissipating inlets
87
Table 3.1 Properties of some trickling filter media. Nominal size (m [ft])
Bulk density (kg/m3 [lb/cu ft])a
Specific surface area (m2/m3 [sq ft/cu ft])b
River
0.024 to 0.076 (0.08 to 0.25)
1442 (90)
62 (19)
50
Slag
0.076 to 0.128 (0.25 to 0.42)
1600 (100)
46 (14)
60
0.61 × 0.61 × 1.22 (2 × 2 × 4)
24 to 45 (1.5 to 2.8)
100, 138, and 223 (30, 42, and 68)
95
0.61 × 0.61 × 1.22 (2 × 2 × 4)
24 to 45 (1.5 to 2.8)
102 and 131 (31 and 40)
95
Media type
Material
Void space (%)
Rock
Plasticc
Cross-flow PVC
Vertical flow PVC
0.185 ø × 0.051 H (7.3 in. ø × 2-in. H)
Randomd
27 (1.7)
98 (30)
95
Polypropylene a
lb/cu ft × 16.02 = kg/m3.
b
sq ft/cu ft × 3.281 = m2/m3.
Manufacturers of modular plastic media: (formerly) BF Goodrich (Greenville, South Carolina), American Surfpac Corporation (Downingtown, Pennsylvania), NSW (Nordenham, Germany), Munters (Aachen, Germany), (currently) Brentwood Industries (Reading, Pennsylvania), Jaeger Environmental (Houston, Texas), and SPX Cooling (Overland Park, Kansas).
c
d
Manufacturers of random plastic media: (formerly) NSW and (currently) Jaeger Environmental.
88
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
and flocculator-type feed wells. Replacement of the rock media (with synthetic media) may be required in cases where rock quality is poor. If WWTP expansion is expected, existing rock-media trickling filters may be deepened if the media is replaced with modular synthetic media. Rock-media trickling filter containment structures typically are capable of providing structural support for the deeper modular synthetic media, because the rock media is substantially heavier than synthetic media. A well-designed and -operated rock-media trickling filter can provide high-quality effluent. Grady et al. (1999) suggested that, under low organic loading (i.e., less than 1 kg BOD5/m3∙d), rock- and synthetic-media trickling filters are capable of equivalent performance. However, as organic loading increases, synthetic-media trickling filters are less susceptible to operational problems and have reduced potential for plugging. Synthetic trickling filter media has a higher specific surface area and void space and lower unit weight than rock media. Because of the reduced unit weight, synthetic-media trickling filters can be constructed at depths exceeding 3 times that of a comparably sized rock-media trickling filter. Modular synthetic media generally is manufactured with the following specific surface areas: 223 m2/m3 (68 sq ft/cu ft) as high-density, 138 m2/m3 (42 sq ft/cu ft) as medium-density, and 100 m2/m3 (30 sq ft/cu ft) as low-density. Both vertical- and cross-flow media are reported to remove 5-day biochemical oxygen demand (BOD5) and ammonia-nitrogen (NH3-N) (Aryan and Johnson, 1987; Harrison and Daigger, 1987), but sufficient scientific evidence exists to surmise that there is a difference in the treatment efficiency of trickling filters constructed with cross- and vertical-flow media, even when manufactured with virtually identical specific surface areas. Plastic modules with a specific surface area in the range of 89 to 102 m2/m3 are wellsuited for carbon oxidation and combined carbon oxidation and nitrification. Parker et al. (1989) recommended medium-density cross-flow media and recommended against the use of high-density cross-flow media in nitrifying trickling filters. This is supported by observations from a pilot-scale nitrifying trickling filter application data and the conclusions of Boller and Gujer (1986) and Gujer and Boller (1984), which show lower nitrification (flux) rates for lower density modular synthetic media. The researchers claim that lower rates occur with high-density media, as a result of the development of dry spots below the flow interruption points (i.e., higher-density media has more flow interruptions and therefore less effective wetting). Using medium-density media also reduces plugging potential. Vertically oriented modular synthetic (verticalflow) media generally is accepted as being ideally suited for high-strength wastewater (perhaps industrial) and high organic loadings, such as with a roughing trickling filter.
89
90
Biofilm Reactors
In some cases, cross-flow media has been placed in the top layer to enhance wastewater distribution, and vertical-flow media comprises the remainder of the trickling filter media. Typically, the top layer of a trickling filter’s modular plastic media is covered with fiberglass-reinforced plastic (FRP) or high-density polyethylene (HDPE) grating. The grating is skid-resistant, thereby reducing the potential for slip and fall occupational hazards. In addition, the grating protects modular plastic media from deterioration by UV light and potential structural damage, which may result from water-induced load exerted during periods of high-intensity dosing.
2.3 Containment Structure Rock and random synthetic media are not self-supporting and require structural support to contain the media within the bioreactor. These containment structures are typically precast or panel-type concrete tanks. When self-supporting media, such as plastic modules, is used, other materials, such as wood, fiberglass, and coated steel have been used as containment structures. The containment structure serves to avoid wastewater splashing and provide media support, wind protection, and flood containment. In some cases, trickling filter containment structures have been designed to allow flooding of the media, which increases operator flexibility in controlling macrofauna accumulation. A complete list and description of macrofauna control alternatives is presented later in this chapter.
2.4 Underdrain System and Ventilation The trickling filter underdrain system is designed to meet two objectives—collect treated wastewater for conveyance to downstream unit processes and create a plenum that allows for the transfer of air throughout the trickling filter media (Grady et al., 1999). Clay or concrete underdrain blocks commonly are used for rock-media trickling filters because of the required structural support. A variety of support systems, including concrete piers and FRP grating are used for other media types. Figure 3.3 illustrates field-adjustable plastic stanchions and FRP grating on the concrete floor of a trickling filter containment structure. The volume created between the concrete and media bottom creates the underdrain. The vertical flow of air through the media can be induced mechanically or by natural air draft. Natural air ventilation results from a difference in ambient air temperature outside and inside the trickling filter. The temperature causes air to expand when warmed or contract when cooled. The net result is an air-density gradient throughout the trickling filter, and an air front either rises or sinks, depending on the differential
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
Figure 3.3 Adjustable plastic stanchions (top right) and FRP grating (bottom left) on the concrete floor of a bolted steel containment structure, and an HDPE mat used to support random synthetic media (top and bottom right).
condition. This rising or sinking action results in a continuous airflow through the bioreactor. Natural ventilation may become unreliable or inadequate in meeting process air requirements, when neutral temperature gradients do not produce air movement. Such conditions may be daily or seasonal and can lead to odorous anaerobic biofilm conditions and poor trickling filter performance. Therefore, mechanical ventilation generally is included to enhance and control airflow. Mechanical ventilation is accomplished with low-pressure fans to continuously circulate air throughout the trickling filter. When using mechanical ventilation, the designer must ensure that air is distributed uniformly across the trickling filter cross-section.
2.5 Trickling Filter Pumping Stations: Influent and Recirculation A critical unit in the trickling filter process is the pumping station that lifts primary effluent (or screened raw wastewater) and recirculates unsettled trickling effluent (referred to here as underflow) to the influent stream. Generally, trickling filter underflow is recirculated to the distribution system to achieve the hydraulic load (influent + recirculation) required for proper media-wetting and biofilm thickness control and decouple hydraulic and organic loading. Although effluent from the secondary
91
92
Biofilm Reactors
clarifier can be recirculated, this not common practice, because it may lead to the hydraulic overloading of secondary clarifiers. Trickling filter influent generally is pumped to allow trickling filter underflow to flow by gravity to the SGR (or solids contact basin), secondary clarifier, or other downstream of the trickling filter. When fit with weirs, a single pumping station can be used to convey both influent and recirculation streams.
2.6 Hydraulic and Contaminant Loading Trickling filters typically are classified by the intended mode of pollutant degradation and pollutant loading, namely carbon oxidation, combined carbon oxidation and nitrification, or nitrification. Organic loading typically is expressed as kilograms per day per cubic meter (kg/d·m3) of filter media as carbonaceous 5-day biochemical oxygen demand (cBOD5). General practice is to ignore the organic load imparted by recirculation streams, but the designer should be aware of the effects that recycle flow and pollutant loading (specifically ammonia-nitrogen) may have on treatment efficiency. Total organic load (TOL) may be calculated by eq 3.1.
Q in ⋅ S S,in BOD 5 applied = TOl = media volume VM
(3.1)
where VM = trickling filter media volume (m3). Nitrifying trickling filter data typically are expressed in terms of the surface-based ammonia-nitrogen loading rate. Dividing eq 3.1 by the media specific surface area (m2/m3) produces the surface loading rate. The trickling filter hydraulic loading rate can be calculated with and without recirculation. The wastewater hydraulic load, WHL (in cubic meters per square meters per day), excludes recirculation and can be calculated mathematically by eq 3.2, which has the units cubic meters per square meters per day. Q in (3.2) a The total hydraulic load (THL) is relevant for media-wetting and biofilm thickness control and considers trickling filter influent, Qin, and recirculation stream, QR. The total hydraulic load can be expressed mathematically by eq 3.3. wHl =
THl =
Q in + Q R a
(3.3)
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
3.0 Process Flow Sheets and Bioreactor Configuration The wastewater treatment train of a trickling filter process typically consists of preliminary treatment (including screening and grit removal), primary clarification, trickling filter influent/recirculation pumping station, secondary clarification, and disinfection unit processes. The TF/SG processes also include an aeration basin and return activated sludge pumping station. This section describes standard process flow sheets, different trickling filter classifications, and hydraulics.
3.1 Standard Process Flow Diagrams The trickling filter recirculation stream influences process flow. Generally, there are two types of trickling filter recirculation. The first allows for direct recirculation to the trickling filter, and the second passes flow through a primary clarifier before entering the trickling filter. Four trickling filter process flow diagrams, including both singleand two-stage trickling filters, are shown schematically in Figure 3.4. Combined TG/ SG process flow sheets are illustrated in Figure 3.5. Recirculation of trickling filter underflow or settled effluent dilutes influent wastewater and dampens the influent organic loading variability, as a result of diurnal fluctuations. Clarifying trickling filter effluent may enhance the performance of a subsequent trickling filter in twostage operation, but the designer must ensure that the recirculation flow required for trickling filter wetting and biofilm thickness control does not exceed the limiting hydraulic loading rate for the sedimentation tank. Intermediate clarification may be beneficial for systems treating wastewaters containing high concentrations of soluble cBOD5 (likely from an industrial source) because of excessive biomass production. These solids can adversely affect the second-stage trickling filter, if not removed by intermediate settling. The design of settling tanks in two-stage trickling filter systems also is affected by the recirculation pattern. The practice of alternating the lead trickling filter in a primary–secondary trickling system is referred to as an alternating double-filtration (ADF) system. This concept is beneficial when applied to modular synthetic-media trickling filters. Gujer and Boller (1986) and Parker et al. (1989) observed patchy biofilm growth in the lower section of pilot-scale nitrifying trickling filters (NTFs). The researchers attributed the patchy growth to dry spots. Boller and Gujer (1986) recommended the use of ADF to enhance pilot-scale NTF performance. Aspegren (1992) also observed improved nitrification using ADF compared with a single-stage NTF and reported that the
93
TFINF
RS
PE
TF
PC TFRCY
PE
TF
PC PS
TFEFF
WS
TFINF-2
TF
TF
(c)
TFEFF
PC
SE SC
TFRCY
PS
WS
TFINF-1
PE
TF
PC PS
(b)
SE SC
PE
RS
(a)
WS
TFRCY
TFINF-1
RS
SE SC
PS
RS
TFEFF
TFINF-2
TFEFF
ICE
TF
IC TFRCY-1
WS
(d)
TFEFF
SE SC
TFRCY-1
WS
Figure 3.4 Typical flow diagrams for the trickling filter process: (a) and (b) singlestage trickling filter process, (c) two-stage trickling filter process, and (d) two-stage trickling filter process with intermediate clarification. RS = raw sewage, PC = primary clarifier, PS = primary sludge, PE = primary effluent, TFINF = trickling filter influent, TF = trickling filter, TFEFF = trickling filter effluent, TFRCY = trickling filter recycle, SC = secondary clarifier, WS = waste sludge, SE = secondary effluent, IC = intermediate clarifier, and ICE = intermediate clarifier effluent. 94
TFINF
RS
PE
ABF
TFEFF
PC
SE
TFRCY
PS
RAS
RS
PE
TF
PC
WS
TFEFF
MLSS
TFRCY
PE
ABF
PC
RAS
TFEFF
(b)
WS
MLSS
SE
(c)
SecC
SC/AS
TFRCY
PS
SE SecC
SC/AS
PS
RS
(a)
SecC
RAS
WS
TFINF-1 (d) RS
PE
TF
PC PS
TFRCY-1
TFEFF
MLSS
ICE IC WS
SE SecC
AS RAS
WS
Figure 3.5 Typical flow diagrams for trickling filter-suspended growth processes: (a) activated biofilter, (b) trickling filter/solids contact or trickling filter/activated sludge, (c) activated biofilter/solids contact or activated biofilter/activated sludge, and (d) trickling filter and activated sludge. ABF = activated biofilter, AS = activated sludge, SC = solids contact, RAS = return activated sludge, and SecC = secondary clarifier; other variables as defined in Figure 3.4. 95
96
Biofilm Reactors
improved performance resulted from the reduced biofilm patchiness. Use of the ADF approach with two trickling filters in series encourages full-depth biofilm development in both bioreactors. The lead trickling filter should be switched every 3 to 7 days, to ensure that healthy biofilms, which maximize media coverage, are developed along the entire bioreactor depth. The primary drawback of ADF is an increased power requirement, which may be in excess of 50%, as a result of double pumping. In addition to increased operating cost, capital costs associated with pipes and valves also will increase. Sludge handling also affects the trickling filter process. Each of the process-flow diagrams illustrated in Figures 3.4 and 3.5 implies that waste biological solids are removed by co-settling the biological sludge with the primary sludge before withdrawal from the system. Many facilities exist that separately handle the primary and secondary sludge. The benefits of each must be evaluated by the designer. This practice does require that operators conscientiously withdraw the solids from the process and that designers provide equipment and means to maintain a near-zero sludge blanket, if necessary. A common operational problem resulting from improper maintenance of biosolids is “rising sludge.” Any trickling filter application that results in nitrification produces nitrate, which is reduced to nitrogen gas (N2) in an anoxic sludge blanket macroenvironment (and the presence of an electron donor). The N2 (g) can become entrained in the sludge blanket and float biomass to the sedimentation basin water surface. This biomass can float over the weirs and degrade secondary effluent water quality. Another issue that designers must consider is the improper maintenance of a primary clarifier sludge blanket. When combined with waste biological sludge, the soluble cBOD5 that exists in primary sludge may generate odor. Alternatively, particulate BOD5 may hydrolyze and cause soluble BOD5 to enter the bulk liquid. This can result in an increased TOL (on the trickling filter) and diminish bioreactor performance.
3.2 Bioreactor Classification Trickling filters can be categorized by four modes of operation or application—(1) roughing, (2) carbon oxidation, (3) carbon oxidation and nitrification, and (4) nitrification. Table 3.2 summarizes generally accepted criteria defining each operational mode. Roughing filters receive high hydraulic and high organic loadings and generally are constructed with vertical-flow media to minimize the potential for excess biofilm accumulation. Although they may provide a high quantity of organic load removal per unit volume, their settled effluent still contains substantial BOD5. Roughing filters provide approximately 50 to 75% soluble BOD5 conversion and may receive total
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
97
Table 3.2 Trickling filter classification. Carbon oxidizing cBOD5 and (cBOD5 removal) nitrification
Design parametera
Roughing
Media typically used
Vertical flow
Rock, cross-flow, or vertical flow
Rock, cross-flow, or vertical flow
Cross-flow
Wastewater source
Primary effluent
Primary effluent
Primary effluent
Secondary effluent
Hydraulic loading
52.8 to 178.2 (0.9 to 2.9)
14.7 to 88.0 (0.25b to 1.5)
14.7 to 88.0 (0.25b to 1.5)
35.2 to 88.0 (0.6 to 1.5)
1.6 to 3.52 (100 to 220)
0.32 to 0.96 (20 to 60)
0.08 to 0.24 (5 to 15)
NAc
NAc
NAc
0.2 to 1.0 (0.04 to 0.2)
0.5 to 2.4 (0.1 to 0.5)
Effluent quality (mg/L) (unless noted)
50 to 75% filtered cBOD5 conversion
15 to 30 mg/L cBOD5 and TSSd
<10 cBOD5; <3 NH3-Nd
0.5 to 3 NH3-Nb
Predation
No appreciable growth
Beneficial
Detrimental Detrimental (nitrifying biofilm)
Filter flies
No appreciable growth
No appreciable growth
No appreciable growth
No appreciable growth
Depth (m [ft])
0.91 to 6.10 (3 to 20)
≤12.2 (40)
≤12.2 (40)
≤12.2 (40)
m 3 (gpm/sq ft) d.m 2
Nitrification
BOD5 and NH3-N load kg m 3 .d g m 2 .d
(lb BOD5/d·1000 cu ft) (lb NH3-N/d·1000 sq ft)
gpm/sq ft × 58.674 = m3/m2·d (cubic meter per day per square meter of trickling filter plan area); lb BOD5/ d/1000 cu ft × 0.0160 = kg/m3∙d (kilograms per day per cubic meter of media); and lb NH3-N/d/1000 sq ft × 4.88 = g/m2∙d (grams per day per square meter of media). a
b Applicable to shallow trickling filters. gpm/sq ft = gallons per minute per square foot of trickling filter plan area. c
Not applicable.
d
Concentration remaining in the clarifier effluent stream.
BOD5 loadings of 1.5 to 3.5 kg BOD5/m3∙d. Carbon-oxidizing trickling filters may provide settled effluent concentrations of 15 to 30 mg/L for BOD5 and TSS, respectively, and may receive BOD5 loadings of 0.7 to 1.5 kg/m3∙d. Combined carbon oxidation and nitrification trickling filters may provide an effluent BOD5 concentration less than 10 mg/L and NH3-N less than or equal to 0.5 to 3 mg/L (after solids separation). These trickling filters may receive BOD5 loadings less than 0.2 kg/m3∙d and TKN loadings
98
Biofilm Reactors
of 0.2 to 1.0 g/m2∙d. The NTFs provide 0.5 to 3 mg/L effluent NH3-N when receiving a clarified secondary effluent and NH3-N loadings of 0.5 to 2.5 g N/m2∙d.
3.3 Hydraulic Application: Effect on Media Wetting, Flow Distribution, and Control Recirculation and distributor operation are important to good trickling filter performance and may be used to achieve proper media-wetting, flow distribution, biofilm thickness control, and prevent macrofauna accumulation. Albertson and Eckenfelder (1984) postulated that the active biofilm surface area in a trickling filter is dependent on biofilm thickness and media configuration and that the active biofilm surface area decreases with increasing biofilm thickness. The researchers stated that, for mediumdensity cross-flow media with 98 m2/m3 specific surface area, a 4-mm increase in biofilm thickness would cause a 12% reduction of active biofilm area (assuming that the entire media has been appropriately wetted). Poor trickling filter media-wetting results in reduced effluent water quality. In a study of rotary distributor efficiency, Crine et al. (1990) found that the wetted-area-to-specific-surface-area ratio ranged from 0.2 to 0.6, with the lowest values for high-density random-pack media. Figure 3.6 shows a threedimensional representation of liquid-flow distribution in cross-flow media, both with and without biofilm (Lekhlif et al., 1994). Many of the later mentioned design formulations incorporate a term that allows for specific surface area reduction, as a result of
(a)
(b)
Figure 3.6 Three-dimensional representation of liquid flow distribution in crossflow media, both (a) with and (b) without biofilm (Lekhlif et al., 1994).
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
distributor inefficiency in trickling filter media-wetting. The interrelationship of liquid residence time, dosing, and media configuration on BOD5 removal kinetics has not been addressed, and additional research is required. Increasing the average hydraulic application rate reduces the liquid residence time, but has been proven to increase wetting efficiency. The recirculation ratio (Q/QR) typically is in the range 0.5 to 4.0. Data obtained by Dow Chemical Company (Bryan, 1955, 1962; Bryan and Moeller, 1960) demonstrate that vertical-flow media require an average application rate exceeding 1.8 m3/m2·h to maximize the BOD5 removal efficiency. Shallow towers using crossflow media have used hydraulic rates in the range 0.4 to 1.1 m3/m2·h. Slowed distributor operation has benefited trickling filter facilities because of interrupted flow (periodicity of dosing), increasing wetting efficiency (percent of media wetted), and biofilm thickness control. The designer should consider recirculation capabilities, the effect of reverse-thrusting jets, or the use of speed control on the distributor, to enhance performance or improve operation. A German-developed (ATV, 1983) process control parameter, referred to as Spülkraft, allows for the calculation of a dosing rate (mm/pass) by eq 3.4. mm m Sk = mi N a ⋅ ω d ⋅ 60 hour THl ⋅ 1000
Where SK = Spülkraft (mm/pass), Na = number of arms on the distributor, and ωa = distributor rotational speed (rpm).
(3.4)
The typical hydraulically driven distributor in North America operates in the range 2 to 10 mm/pass. Table 3.3 lists recommended dosing rates for rotary distributors. Higher dosing rates are recommended for higher organic loading rates, to enhance biofilm thickness control. Besides a normal operating dosing rate, it may be beneficial to periodically use a higher flushing dosing rate for 5 to 10% of the 24-hour operating period. Albertson (1989a, 1989b, 1995) and Parker and coworkers (Parker, 1999; Parker et al., 1995, 1997) demonstrated that biofilm thickness control enhanced nitrification in the trickling filter process, reduced odors, reduced power use for recycling, reduced the accumulation of nuisance organisms, and eliminated heavy sloughing cycles. Parker and coworkers (Parker, 1999; Parker et al., 1995, 1997) recommended the use of VFD-controlled recirculation pumps and distributor speed control
99
100
Biofilm Reactors
Table 3.3 Operating and flushing dosing rates for distributors.* Total organic load (kg/m3·d [lb BOD5/d·1000 cu ft])
Operating dosing rate (mm/pass [in./pass])
Flushing dosing rate (mm/pass [in./pass])
<0.4 (<25)
25 to 75 (1 to 3)
100 (4)
0.8 (50)
50 to 150 (2 to 6)
150 (6)
1.2 (75)
75 to 225 (3 to 9)
225 (9)
1.6 (100)
100 to 300 (4 to 12)
300 (12)
2.4 (150)
150 to 450 (6 to 18)
450 (18)
3.2 (200)
200 to 600 (8 to 24)
600 (24)
*Actual values are site-specific and vary with media type.
(if necessary) to maintain constant trickling filter hydraulic application. Parker et al. (1995) conducted pilot studies, which demonstrated that mechanically driven distributor dosing alone did not improve the performance of an NTF. Parker (1999) has pointed out that there is little research describing the effect of hydraulic transients on synthetic trickling filter media and their effect on media life.
4.0 Ventilation and Air Supply Alternatives Trickling filters require oxygen to sustain aerobic biochemical transformation processes. Several researchers have demonstrated that at least some portion (if not the entire bioreactor) of roughing, carbon-oxidizing, combined carbon-oxidizing and nitrification, and NTFs operates under oxygen-limited conditions (Kuenen et al., 1986; Okey and Albertson, 1989a; Schroeder and Tchobanoglous, 1976). Ventilation is essential to maintain aerobic conditions in a trickling filter. The vertical flow of air through trickling filter biofilm carriers can be induced by natural air draft or mechanical ventilation. Mechanical ventilation enhances and controls airflow with low-pressure fans, which continuously circulate air throughout the trickling filter. Current design practice requires the provision of adequate underdrain and effluent channel sizing to permit free airflow. Passive devices for ventilation include vent stacks on the trickling filter periphery, extensions of underdrains through trickling filter side walls, ventilating manholes, louvers on the side wall of the tower near the underdrain, and discharge of trickling effluent to the subsequent settling basin in an open channel or partially filled pipes.
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
4.1 Natural Draft Naturally occurring airflow results from a difference in ambient air temperature and humidity outside and inside the trickling filter. The temperature causes air to expand when warmed or contract when cooled. The result is an air-density gradient throughout the trickling filter, and an air front rises or sinks, depending on the differential condition. This rising or sinking action results in a continuous airflow through the bioreactor. If the air inside the trickling filter is colder than the ambient air, the air will flow downward. Alternatively, if the ambient air is colder than the air inside trickling filter, air will flow upward. Schroeder and Tchobanoglous (1976) state that upward airflow is the worst case from a mass-transfer perspective, because the dissolved oxygen driving force is lowest in the region of highest oxygen demand (i.e., the top of the trickling filter). Natural ventilation may become unreliable or inadequate in meeting process air requirements when neutral temperatures do not produce air movement. Such conditions may be daily or seasonal and can lead to the development of anaerobic biofilms and poor trickling filter performance. Modular synthetic-media trickling filters that rely on natural draft to provide process oxygen for municipal wastewater treatment should include the following design features: • Drains, channels, and pipes should be sized sufficiently to prevent submergence greater than 50% of their cross-sectional area under design hydraulic loading. • Ventilating access ports with open grating covers should be installed at both ends of the central collection channel. • Large-diameter trickling filters typically have branch channels (to collect the treated wastewater). • These branches also should include ventilating manholes or vent stacks installed at the trickling filter periphery. • The open area of the slots in the top of the underdrain blocks should not be less than 15% of the trickling filter area. • Approximately a 1-m2 gross area of open grating in ventilating manholes and vent stacks should be provided for each 23 m2 of trickling filter area. Typically, 0.1 m2 of ventilating area is provided for every 3 to 4.6 m of trickling filter periphery, and 1 to 2 m2 of ventilation area is provided in the underdrain area per 1000 m3 of trickling filter media. • Another criterion for rock-media trickling filters is the provision of a vent area at least equal to 15% of the trickling filter cross-sectional area.
101
102
Biofilm Reactors
4.2 Mechanical Ventilation A majority of new and improved trickling filters use low-pressure fans to mechanically induce airflow. The airflow resulting from natural draft will distribute itself; this will not occur with mechanical ventilation. Pressure loss through synthetic trickling filter media typically is low—often less than 1-mm water (H2O) per meter of trickling filter depth (Grady et al., 1999). The low pressure drop typically results in low fan power requirements (approximately 3 to 5 kW). The head on the fan typically is less than 1500-mm H2O. Unfortunately, the low pressure drop allows air to rise upward through the trickling filter media without distributing itself across the bioreactor section. Therefore, fans typically are connected to distribution pipes. The airflow distribution piping has openings sized such that airflow through each is equal and airflow distribution is uniform. The pipes typically have a velocity in the range 1100 to 2200 m/h, to further promote uniform airflow distribution. Airflow requirements are calculated based on process oxygen requirements and characteristic oxygen transfer efficiency, which is typically in the range 2 to 10%. The mechanical air stream may flow upward to downward. Downflow systems can be designed without covers; however, covers are required for systems that do not have air distribution through a network of pipes under the media. Covering trickling filters offers a benefit in winter of limiting cold airflow and minimizing wastewater cooling. Mechanical ventilation and covered trickling filters may be used to destroy odorous compounds. A trickling filter mechanical aeration system (distribution pipes and fans) is pictured in Figure 3.7. (a)
(b)
Figure 3.7 (a) Trickling filter underdrain and media supports with air distribution piping throughout the underdrain, and (b) typical low-pressure fan applied to provide process air.
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
5.0 Trickling Filter Process Models Numerous investigators have attempted to delineate the fundamentals of the trickling filter process, by developing relationships among variables that affect bioreactor operation. Existing trickling filter process models range in complexity, from simplistic empirical formulations to complex mathematical models. Analyses of operating data have been made to establish equations or curves to fit available data. Results of these data analyses have led to the development of various empirical formulas that describe trickling filter performance. Unfortunately, numerous models exist, and there is lack of industry standard defining a method for the selection of an appropriate process model. Trickling filter models may be classified as dissolved organic loading-based models, particulate organic loading-based models, hydraulic loading-based models, and mass-transfer models. Although these formulas represent attempts to include key variables that have been observed to affect trickling filter operation, none of the formulas adequately describe the complex processes that are characteristic of trickling filter bioreactors. Designers need to assess which equation best fits a particular situation when selecting which model to apply in a particular design, especially with regard to the confidence level necessary to meet project-specific effluent water quality (permit) requirements. The following models are discussed in this section:
(1) National Research Council (1946); (2) Galler and Gotaas (1964); (3) Kincannon and Stover (1982); (4) Velz (1948); (5) Schulze (1960); (6) Germain (1966); (7) Eckenfelder and Barnhart (1963); (8) Chartered Institution of Water and Environmental Management (1988); and (9) Logan trickling filter model (TRIFL) (Logan et al., 1987a, 1987b).
5.1 National Research Council The National Research Council (Washington, D.C.) (NRC) formula (1946) resulted from an extensive analysis of operational records from full-scale rock‑media trickling filters serving military installations. The NRC data analysis demonstrated that cBOD5 removal in the rock-media trickling filters studied was dependent on contact time between the biofilm and bulk liquid, which is dependent on bioreactor dimensions and the number of passes. The removal efficiency of cBOD5 increases with contact
103
104
Biofilm Reactors
time. Because treatment efficiency decreases with organic load, the primary determinant of treatment efficiency in a rock-media trickling filter, according to the NRC formulas, is increased contact (with the biofilm surface) and applied load. For the 34 rock‑media trickling filter installations evaluated during the NRC study, a curvefitting effort resulted in eqs 3.5 and 3.6 for single-stage and second-stage trickling filters, respectively.
E1 =
E2 =
100 W 1 + 0.0085 ⋅ V ⋅ F
0.5
(3.5)
100 W2 1 + 0.0085 ⋅ E V⋅ F 1− 1 100
(3.6)
Where E1 = BOD5 removal efficiency through the first‑stage trickling filter and settling tank (%); W1 = BOD5 loading to the first‑ or single‑stage trickling filter, not including recycle (kg/d [lb/d]); V = volume of the trickling filter stage (cross-sectional area × media depth) (m3 [ac-ft]); 1+ F = number of organic material passes =
QR Q
QR 1 + ( 1 − P ) ⋅ Q
2
;
QR = dimensionless recirculation ratio; Q P = a weighing factor, for military trickling filters, with rock media = 0.9; E2 = BOD5 removal efficiency through second‑stage trickling filter and settling tank (%); and W2 = BOD5 loading to the second‑stage trickling filter, not including recycle (kg/d [lb/d]). Equations 3.5 and 3.6 are empirical formulas based on data obtained from rock‑ media trickling filters with and without recirculation. Because of the nature of their development, the NRC formulas include the following limitations and conditions:
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
(1) Characteristically, military wastewater has a higher strength (250 to 400 mg BOD5/L) than average domestic wastewater. (2) The effect of temperature on trickling filter performance is not considered (most of the studies were conducted in the Midwest and southern latitudes of the United States). (3) The clarifier design practice, at the time the formulas were developed, favored shallow units that were operated with a higher hydraulic load than recommended in current practice. The shallower clarifiers may have resulted in BOD5 and TSS losses. (4) Applicability may be limited to stronger-than-normal domestic wastewater, because no factor is included to account for differing treatability rates for lower-strength wastewater.
The formula for second‑stage trickling filters is based on the existence of intermediate settling tanks following the first‑stage trickling. Results from the NRC formula may deviate substantially from actual trickling filter performance. Scattered data for loadings less than 0.3 kg/m3·d (20 lb/d/1000 cu ft) may be biased by a lack of BOD5 test protocol requiring the inhibition of nitrification during the BOD5 test. Inadequate hydraulic application rate, poor ventilation, and inefficient clarifier design could have contributed to poor trickling filter process performance. Thus, the foregoing should be considered when designing the trickling filter process using the NRC formula(s).
5.2 Galler and Gotaas Galler and Gotaas (1964) attempted to describe the performance of rock-media trickling filters through a multiple regression analysis of data obtained from existing full-scale trickling filters. Equation 3.7 was developed based on an analysis of 322 observations.
Se =
Where
K ⋅ ( Q ⋅ Si + QR ⋅ Se ) 1.19
( Q + QR ) 0.78 ⋅ ( 1+ D ) 0.67 ⋅ ra0.25
43 , 560 0.464 ⋅ π K = coefficient = 0.28 0.15 Q ⋅T
0.13
,
Q = flowrate (ML/d [mgd]), QR = recirculation flowrate (ML/d [mgd]),
(3.7)
105
106
Biofilm Reactors
D = trickling filter depth (m [ft]), Se = settled trickling filter effluent BOD5 concentration at 20°C (mg/L), Si = trickling filter influent BOD5 concentration at 20°C (mg/L), and ra = trickling filter radius (m [ft]). Some key variables of the Galler and Gotaas (1964) formula include recirculation, hydraulic loading, trickling filter depth, and wastewater temperature. According to their analysis, deeper trickling filters increased BOD5 removal. The researchers further indicated that recirculation improved trickling filter performance, but established a 4:1 ratio as a practical upper limit for recirculation. The hydraulic flowrate through the trickling filter was found to be statistically unimportant in determining the bioreactor treatment efficiency. The statistical analysis performed by Galler and Gotaas (1964) suggested that BOD5 loading was, statistically, the most significant parameter for describing bioreactor performance.
5.3 Kincannon and Stover Kincannon and Stover (1982) developed a mathematical model based on a relationship between the specific substrate utilization rate and total organic loading, which followed a Monod plot to determine the required biofilm area. The relationship is described mathematically by eq 3.8.
8.345 ⋅ q ⋅ Si µ ⋅ S max i − Kb As = Si − Se
(3.8)
Where Si = influent BOD5 concentration (mg/L), Se = effluent BOD5 concentration (mg/L), and Kb = proportionality constant of specific surface area (m2). Biokinetic parameters, namely the maximum specific substrate utilization rate and Monod-type half-saturation constant (or μmax and Ki, respectively), are reported based on pilot‑plant tests, full‑scale observations, or a summary of previous experiences. When extracting these parameters from test data, these parameters may be determined graphically by plotting BOD5 loading versus the inverse of BOD5 removed. The y intercept is μmax-1, and the slope is Kb. According to the Kincannon and Stover (1982) model, BOD5 removal is most sensitive to volumetric loading and treatability. The BOD5 removal is not influenced by trickling filter depth.
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
5.4 Velz Velz (1948) proposed the first formulation based on a fundamental law, in contrast with previous empirical attempts, which were based on data analyses. The Velz equation (eq 3.9) relates BOD5 remaining in the bulk phase as follows: Se = 10− kV ⋅ t Si
(3.9)
Where Si = influent BOD5 concentration (mg/L), SD = BOD5 concentration remaining at filter depth D (mg/L), t = residence time (days), and kV = Velz first-order rate constant (d-1). Equation 3.9 suggests that kV is constant for all hydraulic rates; however, Albertson and Davies (1984) presented evidence that kV varies with the hydraulic rate. The Velz equation is presented herein because of its foundation of later-developed design formulations, which are applied in present day design, namely the Eckenfelder and Barnhart (1963) and Schulze (1960) equations.
5.5 Schulze Schulze (1960) postulated that the tome liquid that is in contact with the biofilm is directly proportional to the trickling filter depth and inversely proportional to the hydraulic loading rate. This is expressed by eq 3.10.
Where
tc =
c⋅ D THln
(3.10)
tc = liquid contact time (days), c = constant (dimensionless), D = trickling filter depth (m), THL = hydraulic loading rate (m3/m2·d), and n = exponent on hydraulic loading (dimensionless). Combining the time of contact with the first‑order equation for BOD5 removal in an adaptation of the Velz (1948) equation, Schulze derived the following formula (eq 3.11):
Se =e Si
− kS ⋅ D THln
(3.11)
107
108
Biofilm Reactors
Where Se = soluble BOD5 in trickling filter effluent stream (mg/L), Si = soluble BOD5 in trickling filter influent stream (mg/L), kS = Schulze coefficient (d−1 when n = 1), D = trickling filter depth (m), N = exponent on hydraulic loading (dimensionless), and THL = hydraulic loading rate (m3/m2·d). Equation 3.11 is similar to that proposed by Velz (1948). However, Velz’s constant, kV, was not formulated to consider hydraulic load. For a given wastewater strength, the hydraulic rate is proportional to the loading rate. Thus, volumetric organic loading still may be the controlling process variable. The value of kS published by Schulze (based on United States customary units) for a rock-media trickling filter with a 1.8‑m (6‑ft) depth at 20°C was 0.69 day-1. The dimensionless constant characteristic of rockmedia trickling filter, n, was found to be 0.67. The common temperature correction value of θ = 1.035 could be applied to determine kt, as follows: kt = k20 × 1.035( T − 20 ) for ks
(3.12)
Where kt = temperature-corrected coefficient value (d-1 when n = 1), kS = Schulze coefficient (d-1 when n = 1), and As = clean surface area of the media (m2).
5.6 Germain Germain (1966) applied the Schulze (1960) formulation to a synthetic-media trickling filter (eq 3.13). − k ⋅D
Where
G Se n = e THL Si
(3.13)
Si = soluble BOD5 in trickling filter influent stream (typically primary effluent excluding recirculation) (mg/L), THL = hydraulic loading rate (m3/m2·d), and kG = Germain coefficient (d-1 when n = 1). The values of kG and n are related to media configuration, secondary clarifier efficiency, dosing, and hydraulic application rate; k G is a function of wastewater
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
characteristics, trickling filter depth, media specific surface area, and configuration. Therefore, because a high degree of interdependency exists between kG and n, this must be considered in data comparisons. Germain (1966) reported the value of kG of 0.24 (L/s)n∙m2 (0.088 gpmn/sq ft) for a synthetic-media trickling filter having a 6.6 m (21.5 ft) depth and treating domestic wastewater with a value of 0.5 for n. This verticalflow media had a clean surface area of 89 m2/m3. Correction of kG for the high BOD5 concentration represented by the Chartered Institution of Water and Environmental 150 Management (London, United Kingdom) (CIWEM) model, kG 360
0.5
, resulted
in similar predictive values from these two models for plastic media operating in the loading range of 0.2 to 1.5 kg/m3·d at 20°C. In tests designed to determine the effects of recirculation on BOD 5 removal, Germain (1966) found no statistically significant difference. However, the relatively tall (6.6 m) tower resulted in high influent application rates, which ensured adequate media-wetting. This observation is consistent with the practice of using recirculation for shallow trickling filters subject to low influent hydraulic rates and likely inefficient wetting. Equation 3.13 has been used extensively for synthetic-media trickling filter analysis and design. The kG data were developed from more than 140 pilot studies performed by Dow Chemical Company and others. Most of these tests used a trickling filter media depth of 6 to 7 m.
5.7 Eckenfelder Eckenfelder and Barnhart (1963) expanded upon previously developed trickling filter formulas, which account for trickling filter media specific surface area. The formula proposed for soluble BOD5 removal can be expressed mathematically by eq 3.14. Se =e Si
− kS’ ⋅ a( 1+ b ) ⋅ D THLn
(3.14)
Where kS’ = overall treatability coefficient based on soluble BOD5 [(m3/d)0.5·m2], D = depth (m), THL = hydraulic loading rate (m3/m2·d), and b = surface area modifier for surface loss with increasing area. With recirculation, eq 3.14 can be extended and expressed mathematically by eq 3.15.
109
110
Biofilm Reactors
− ks’ ⋅ D
n
e WHL Se = Si QR 1 + Q − e
(3.15)
− k ’s ⋅ D WHLn
Using the Eckenfelder formula and kS’ = a × ks, eq 3.15 can be rewritten as eq 3.16; this is known as the modified Velz equation. Si
Se =
kS ⋅ a⋅ D⋅θ ( T − 20 )
QR + 1 Q
QR WHL⋅ Q + 1 ⋅ e
(3.16)
n
−
QR Q
5.8 Chartered Institution of Water and Environmental Management The CIWEM developed a formula describing the BOD5 in trickling filters having rock, random-packed synthetic media, or modular synthetic-plastic media. Equation 3.17, resulting from a multiple regression analysis, follows:
Si = Se
1
(3.17)
a 1 + kC IWEM ⋅ θ ( T − 15 )⋅ VLRn m
Where Si = influent BOD5 concentration (mg/L), Se = effluent BOD5 concentration (mg/L), kCIWEM = kinetic coefficient (mm-1·d n-1), θ = temperature coefficient, a = media specific surface area (m2/m3), m = reduction factor for surface loss with increasing area, VLR = volumetric hydraulic loading rate (m3/d·m3) of trickling filter media, and n = hydraulic rate coefficient. Equation 3.17 has reported coefficients that account for 90% of data variability.
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
• kCIWEM = 0.0204 (rock and random), 0.40 (modular plastic); • θ = 1.111 (rock and random), 1.089 (modular plastic); • m = 1.407 (rock and random), 0.732 (modular plastic); and • n
= 1.249 (rock and random), 1.396 (modular plastic).
The model was developed using data collected from tests performed on a strong domestic wastewater with primary effluent concentrations of 360 mg/L BOD5, 240 mg/L TSS, and 52 mg/L NH3-N. The model predicts a continuous performance curve from low‑ to high‑rate loadings. The trickling filter depths, from which the samples were collected, ranged from 1.74 to 2.10 m; biofilm growth areas ranged from 1.0 to 5.0 m2; and loadings were 0.3 to 16 kg/m3·d. The CIWEM model is temperaturesensitive, which may be caused by site‑specific wastewater characteristics and datareduction procedures. The NRC equations agree with the CIWEM’s projection based on an influent strength of 360 mg/L BOD5 at loadings up to 1.0 kg/m3·d.
5.9 Logan Trickling Filter Model The TRIFL model, which commonly is referred to as the Logan Trickling Filter (LTF) model, is based on characterizing modular synthetic trickling filter media as a series of inclined plates covered with a thick, partially penetrated, biofilm. The rate of soluble chemical oxygen demand (SCOD) removal is determined using a numerical model to solve transport equations that describe biochemical transformation rates resulting from diffusion through a thin liquid film and into the biofilm. Although the model was calibrated using a single data set for only one type of plastic trickling filter media, a variety of laboratory, pilot-plant, and full-scale trickling filter studies have been conducted, which suggest that the LTF model accurately predicts SCOD removal (Bratby et al., 1999; Logan and Wagenseller, 2000; Logan et al., 1987a, 1987b). Unlike kinetic models, the LTF model cannot be described with a single equation; thus, a computer program is required. The computer model of Logan et al. (1987a, 1987b) was developed to predict soluble BOD5 removal in plastic media trickling filters as a function of plastic media geometry. A disadvantage of kinetic models, such as the Velz equation, is that new kinetic (k20) and hydraulic (n) constants may require determination for each type of trickling filter media. The LTF model requires only that the media geometry be measured and input. Consequently, there was no need to recalibrate the model for new synthetic media types. The actual, computer-code-based model (written in Fortran [IBM,
111
112
Biofilm Reactors
San Jose, California]) was given the name TRIFIL2; the LTF model computer program uses tabulated values for a range of conditions for specific media. Dissolved organics that compose SCOD in wastewater are assumed to be equally distributed into a fivecomponent molecular size. As the wastewater flows over the biofilm, the dissolved organics diffuse into the biofilm. Small molecules diffuse faster than larger ones and are predicted to be removed more efficiently. Temperature affects water viscosity (μ), which affects fluid film thickness and thus retention time in the trickling filter media. Changes in chemical diffusion coefficients (D) with temperature (T) are adjusted by D⋅ µ is constant (Welty et al., 1976). The model is available the assumption that T free-of-charge at http://www.engr.psu.edu/ce/enve/logan/bioremediation/ trickling_filter/model.htm (Penn State University, University Park, Pennsylvania). Additional information on the model can be obtained from the original publications cited below and a chapter in Logan (1999).
5.10 Selecting a Trickling Filter Model Design engineers may use various empirical criteria and design formulations for sizing trickling filters. The NRC (1946) (eqs 3.5 and 3.6) or Galler and Gotaas (1964) (eq 3.7) formulas commonly are used for rock-media trickling filter design. The Schulze equation (eq 3.11), Eckenfelder equation (eq 3.14), and CIWEM equation (eq 3.17) are commonly used formulas for both rock- and synthetic-media trickling filter design over a wide range of media-specific surface areas and trickling filter depths. The coefficients k and n vary, however. The word coefficient is used to describe k (or K) and n, because they are not constants or treatability factors. Thus, the value of k in hydraulically based equations can be modified as a function of media depth (D) by eq 3.18, as follows:
D k2 = k1 ⋅ 1 D2
0.5
(3.18)
The variation of k with trickling filter depth is an important consideration. A k-value developed for a specific trickling filter depth should not be used for a different depth without modification. Using data from a number of installations and simultaneous tests, Albertson and Davies (1984) showed that k could be used effectively for any trickling filter configuration, if corrected for depth. However, this
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
research also indicated that inadequate wetting might have produced lower k values than optimum in many studies. The Eckenfelder, Germain, Schulze, and Velz equations are fundamentally the same and have similar limitations. Because the coefficients k (or K) and n are derived empirically, background data are influenced by a host of variables, such as hydraulic loading rate, dosing mechanism, temperature, wastewater characterization, media configuration and depth, and ventilation (i.e., air supply). The above equations have been applied to accurately describe trickling filter performance, but also have been proven to deviate significantly from observed performance. When modifying the trickling filter configuration, the coefficient k (or K) value typically changes, even when considering the same trickling filter media and wastewater. The NRC, Germain, and Eckenfelder equations may be used for rock-media trickling filter design, although it is recognized that the results may be highly variable. In many cases, designers use each of these design models to bracket the design variables before making a design decision. Synthetic-media trickling filters may be designed using the Eckenfelder, Germain, and/or TRIFL models. However, the designer must be aware that much of the historical pilot‑plant and full‑scale data are impaired by a lack of proper dosing (i.e., poor media-wetting and biofilm thickness control). In addition, many pilot plants used to generate coefficients typically used in the design models summarized here were equipped with continuous-flow nozzles. Therefore, the pilotscale units failed to capture the effect of periodic dosing that is typical of full-scale operating trickling filters. The Eckenfelder equation often is used to define soluble organic matter removal efficiency. The beneficial effect of recirculation is reflected in this formula; the benefits were derived from low application rates typical of carbon-oxidizing rock-media trickling filters. The literature values of n were derived from continuous-flow studies. To compare the k values, the use of 0.5 for n is suggested.
5.11 Method for Combining Trickling Filter and Suspended-Growth Models A previous section presented several design models that commonly are used for the design and evaluation of trickling filters, but there is generally a lack of models describing TF/SG systems. Daigger et al. (1993) and Takács et al. (1996) have developed TF/SG process models.
113
114
Biofilm Reactors
The model of Daigger et al. (1993) was established based on performance observations at the Garland WWTP, Garland, Texas. The TF/SG model accounts for SGR autotrophic nitrifier seeding by the trickling filter. The mass of autotrophic nitrifiers propagating toward the SGR is calculated as a function of the ammonia-nitrogen oxidized in the trickling filter. Model inputs include wastewater temperature, SGR solids retention time (SRT), and trickling filter influent and effluent ammonia-nitrogen. The TF/SG process effluent then is calculated with eq 3.19. 2 1 µmax − MCRT + kd ⋅ NH 3eFF + 1 + kd ⋅ NH 3TFe ⋅ K s NH 3eFF + MCRT
(
)
(
)
1 + kd ⋅ NH 3TFe − K s − µmax ⋅ NH 3Pe ⋅ MCRT = 0 (3.19)
(
)
Where
µmax = maximum nitrifier growth rate (d-1), MCRT = mean cell residence time (days), kd = specific decay rate (m/d), Ks = ammonia-nitrogen half-saturation constant (mg/L), NH3,EFF = TF/SG process effluent ammonia-nitrogen (mg/L), NH3,TFE = trickling filter process effluent ammonia-nitrogen (mg/L), and NH3,PE = trickling filter process influent ammonia-nitrogen (mg/L). The performance relationship developed by eq 3.19 is illustrated in Figure 3.8, where the effluent ammonia-nitrogen concentration is plotted as a function of the SGR SRT divided by the minimum nitrifier SRT. There are several curves that correspond to different nitrification efficiencies inside the trickling filter. Detachment of autotrophic nitrifiers from biofilm growing inside the trickling filter allows the SGR to maintain nitrification, even when operating at a nitrification design factor that ordinarily would result in autotrophic nitrifier washout. The model of Daigger et al. (1993) has been evaluated independently by Biesterfeld et al. (2005). The researchers applied the model to performance observations at the Boulder 75th Street WWTP, Boulder, Colorado, and subsequently used the model for process optimization. The researchers noted that the model of Daigger et al. (1993) is primarily dependent on the rate of nitrification inside the trickling filter and SGR SRT.
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
20
Influent Ammonia-N Conc. = 20 mg N/L Temp. = 20°C
Effluent Ammonia - N Conc., mg N/L
18 16 14 12 10
0 20
8 6 4 2 0
Trickling Filter Nitrification Efficiency
40 60 80 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 Suspended Growth SRT SRTmin for Nitrification
Figure 3.8 Effect of SRT in a suspended-growth reactor and nitrification efficiency in an upstream trickling filter on effluent ammonia-nitrogen concentration in a combined TF/SG reactor (Daigger et al., 1993).
6.0 Process Design Basic criteria defining various trickling filter types have been presented. This section describes, in greater detail, process design criteria for combined carbon oxidation and nitrification trickling filter and NTF processes.
6.1 Combined Carbon Oxidation and Nitrification Combined carbon-oxidizing (i.e., cBOD5 removal) and nitrification trickling filters may be used with synthetic or rock media. The effect of combined carbon oxidation and nitrification in rock-media trickling filters is a result of reduced soluble cBOD5 loading. The design of combined carbon oxidation and nitrification in synthetic media trickling filters is empirical (Parker, 1998). The U.S. Environmental Protection Agency (Washington, D.C.) (U.S EPA, 1991) conducted a survey of 10 combined carbon oxidation and nitrification
115
Biofilm Reactors
facilities. Six of the facilities included the TF/SC process. The survey was used to create empirical guides for achieving nitrification in trickling filters based on fullscale observations. The manual for nitrogen control (U.S. EPA, 1993) presented recommended BOD 5 loadings, which also are presented later, to achieve both carbon oxidation and nitrification in a single-stage trickling filter. The kinetics of BOD5 and NH3-N removal in a single-stage trickling filter are complex, and there is a general lack of research describing combined carbon oxidation and nitrification trickling filter mechanics. Therefore, empirical design criteria are described in this section. U.S. EPA (1975) summarized full‑ and pilot‑scale rock-media trickling filter performance data from Lakefield, Minnesota; Allentown, Pennsylvania; Gainesville, Florida; Corvallis, Oregon; Fitchburg, Massachusetts; Ft. Benjamin Harrison, Indiana; Johannesburg, South Africa; and Salford, United Kingdom. Figure 3.9 (U.S. EPA, 1975) was created using the pilot- and full-scale rock-media combined carbon oxidation and nitrification trickling filter data and illustrates a relationship between BOD5 volumetric loading and nitrification efficiency. These observations
100 No Recirculation
80 Nitrification Efficiency, %
116
Recirculation
60
40
20
0
0
10
20
30
40
50
60
BOD5 Load, 1b/1000 cu ft/day
Figure 3.9 Nitrification efficiency versus organic loading in rock-media trickling filters (U.S. EPA, 1975).
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
indicate that an organic loading rate of 0.08 kg BOD5/m3·d (5 lb BOD5/d/1000 cu ft) is required for rock media to achieve approximately 90% nitrification. Recirculation typically improved nitrification, particularly for nitrification efficiencies greater than 50%. Stenquist et al. (1974) related organic loading to nitrification efficiency in a pilotscale combined carbon oxidation and nitrification synthetic-media trickling filter. The researchers observed 89% ammonia-nitrogen removal at an organic loading of 0.36 kg/m3∙d (22 lb/d/1000 cu ft). The nitrification capacity of the trickling filter was reported a function of surface BOD5 loading (kg BOD5/ m2∙d of trickling filter media). Figure 3.10 illustrates results from the studies at Stockton, California (fulland pilot-scale). Daigger et al. (1994) presented an evaluation of three full-scale cross-flow media trickling filters (each having a 100-m2/m3 specific surface area), which were dosed with rotary distributors and designed for combined carbon oxidation and nitrification. The data collected from these installations are presented in Figure 3.11.
100
++ ++ ++ + ++ + + + + + + + + +
Nitrification, %
80
60
+
40
+
+ + + + +
+
+ +
20
0
0
10 20 Effluent Soluble BODsi mg/L
30
Figure 3.10 Nitrification efficiency as a function of filtered, or soluble, BOD5 in the effluent of a vertical-flow media trickling filter at Stockton, California (U.S. EPA, 1975).
117
Biofilm Reactors
100 Rowlett Creek Duck Creek Missouri River
90 80 Nitritication Efficiency (%)
118
Literature Curve for 100 m2/m3 Media (EPA, 1975)
70 60 50 40 30 20 10
0
0.6 0.8 0.2 0.4 Organic Loading (Kg BOD5/m3-day)
1.0
Figure 3.11 Nitrification efficiency versus organic loading in trickling filters (Daigger et al., 1994).
The data suggest that an organic loading less than 0.24 kg BOD5/m3·d (15 lb BOD5/ d/1000 cu ft) is required to achieve 90% ammonia-nitrogen conversion in crossflow media trickling filters. Similar to the observations of Stenquist et al. (1974), synthetic-media trickling filters (specifically vertical- or cross-flow media) are able to meet ammonia-nitrogen conversions in excess of 89% when the BOD5 load is 3 to 4 times greater than that acceptable for rock-media combined carbon oxidation and nitrification trickling filters. Parker and Richards (1986) described test results obtained from Garland, Texas, and Atlanta, Georgia. The results, reported on the basis of average surface loadings, are shown in Figure 3.12. Parker and Richards (1986) compared combined carbon oxidation and nitrification in rock- and synthetic-media trickling filters. When compared on a surface-area-loading basis, their performance is similar.
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
Nitrification efficiency, %
A
100
0
kg/1000 m2·d 10 15
5
Key Media
80
Cross-Flow - 60° Cross-Flow - 45° Vertical
60
20
Depth, ft 10 20
Curve for rock media 40
20
0
0
1.0
2.0
3.0
4.0
5.0
Organic loading, ib BOD5/1000 sq ft/day
kg/1000 m2·d B
Nitrification efficiency, %
100
0
5
10
20
Cross-fow media, garland pilot study Vertical media, garland pilot study
80 60 40 20 0
15
Key
Curve for rock media and garland cross-flow media
Curve for garland vertical media 0
1.0
2.0
3.0
4.0
Organic loading, ib BOD5/1000 sq ft/day
Figure 3.12 Nitrification efficiency versus organic loading in trickling filters (Parker and Richards, 1986). To produce the lowest NH3-N concentrations, biofilm thickness control is recommended to prevent sloughing cycles and macrofauna accumulation by
(1) Constant hydraulic application (dosing), (2) Periodic high-intensity hydraulic application (flushing), (3) Flooding (if the containment structure has been designed to retain water), or (4) A combination of these practices.
119
120
Biofilm Reactors
Daigger et al. (1994) proposed eq 3.20 to describe BOD5 and NH3-N removal in combined carbon oxidation and nitrification trickling filters.
Q VOR = Si + 4.6 ⋅ SNOx -N ⋅ VM
(3.20)
Where VOR = volumetric oxidation rate (kg/m3·d); Si = BOD5 concentration in the influent stream (g/m3); SNOx-N = nitrate/nitrite-nitrogen concentration in the effluent stream (g/m3); Q = flowrate, including recirculation streams (m3/d); and VM = synthetic media volume (m3). Using eq 3.20, Daigger et al. (1994) reported the VOR for three combined carbon oxidation and nitrification trickling filter (with plastic media) processes in the range 0.4 to 1.3 kg/m3·d.
6.2 Nitrifying Trickling Filters Nitrifying trickling filters are a reliable and cost-effective method of NH 3-N conversion. The following design practices have been demonstrated in full-scale application:
(1) Use medium-density cross-flow media to optimize hydraulic distribution and oxygenation; (2) Use mechanical ventilation; (3) Periodically alternate the lead NTF to avoid patchy biofilm development in the lower reaches of the second-stage unit; (4) The influent should be secondary effluent, to minimize competition between bacterial species for substrates inside the biofilm; (5) Maximize wetting efficiency to avoid the formation of dry spots; (6) Dose the NTF at a rate that will minimize the accumulation of macrofauna; and (7) Equalize NH3-N-laden supernatant from solids processing operations to even out diurnal load variability (Parker et al., 1995, 1997).
Benefits to NTFs include low energy consumption, stability, operational simplicity, and reduced sludge yield. The reduced sludge yield and resulting low TSS concentration in the NTF effluent stream has led some units to be constructed without downstream liquid–solid separation units. This is dependent on site-specific treatment objectives and effluent water quality standards. An operational issue that
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
121
can be detrimental to process performance is the control of predatory macrofauna. Therefore, the designer must include means for managing solids and macrofauna laden water resulting from macrofauna control measures. Design and operational features dedicated to macrofauna control are presented in a subsequent section. Nitrifying trickling filters having 6‑ to 12.2‑m (20‑ to 40‑ft) modular plastic media depths has demonstrated improved performance. The NTFs have been constructed with depths up to 12.8 m (42 ft). Shallower units can operate as a two-stage system. Recirculation should be minimized to that required for biofilm thickness control to maximize the NH3-N concentration (i.e., maintain a high driving force). The practice of alternating the lead trickling filter in a two-stage NTF system is referred to as alternating double filtration (ADF). Gujer and Boller (1986) and Parker et al. (1989) observed patchy biofilm growth in the lower section of pilot-scale NTFs. The researchers attributed the patchy growth to dry spots. Aspegren (1992) observed improved nitrification and reduced biofilm patchiness when using ADF. Use of the ADF approach with trickling filters in series promotes full-depth biofilm development in both trickling filters. The lead trickling filter should be switched every 3 to 7 days. The primary drawback of ADF is an increase in power requirements, which may be in excess of 50%, as a result of double pumping. In addition to increased operating cost, capital costs associated with pipes and valves also will increase cost. Parker (1998, 1999) described nitrification efficiency differences in NTFs containing cross-flow and vertical-flow modular synthetic media. Table 3.4 summarizes the observations, which demonstrate that zero-order ammonia-nitrogen fluxes are Table 3.4 Reported zero-order nitrification rates for vertical- and cross-flow media (after Parker, 1998, 1999). Media type
0
Location
Reference
J N (g/m2·d) Temperature range (°C)
Central Valley, Utah
Parker et al. (1989)
XF 140
2.3–3.2
11 to 20
Malmö, Sweden
Parker et al. (1995)
XF 140
1.6–2.8
13 to 20
Littleton/Englewood, Colorado Parker et al. (1997)
XF 140
1.7–2.3
15 to 20
Midland, Michigan
Duddles et al. (1974)
VF 89*
0.9–1.2
7 to 13
Lima, Ohio
Okey and Albertson (1989b)
VF 89*
1.2–1.8
18 to 22
Bloom Township, Illinois
Baxter and Woodman (1973)
VF 89*
1.1–1.2
17 to 20
*Fully corrugated.
Biofilm Reactors
5 4.5 Nitrification rate, gN/m2*d
122
Influent SS > 15 mg/l Influent SS < 15 mg/l
4 3.5 3
SS < 15 mg/l
2.5 2
SS > 15 mg/l
1.5 1 0.5 0
Ammonia concentration, mg N/l 0
3
6
9
12
15
16
21
24
27
30
Figure 3.13 Effect of bulk liquid TSS concentration on nitrification in a pilot-scale NTF (Andersson et al., 1994). greater for cross-flow than vertical-flow media. A factor contributing to the enhanced performance may be improved oxygenation resulting from the increased number of interruption points in cross-flow media (Gujer and Boller, 1986; Parker et al., 1989). Autotrophic nitrifying biofilms are thin when compared with the heterotrophic biofilms, which are primarily responsible for BOD5 removal; therefore, denser cross-flow media can be used in a NTF. The concentration of TSS in the secondary effluent has been shown to have an effect on NTFs (Boller et al., 1990; Parker et al., 1989). Andersson et al. (1994) demonstrated (see Figure 3.13) that the maximum zero-order nitrification rate in a pilotscale NTF apparently decreased from approximately 2.6 g N/m2·d to approximately 1.8 g N/m2·d. Three NTF design models are described in this section. They include (1) the model of Gujer and Boller (1986), (2) the model of Gujer and Boller (1986) with the modification of Parker et al. (1989), and (3) the model of Okey and Albertson (1989b).
6.2.1 Gujer and Boller Nitrifying Trickling Filter Model Gujer and Boller (1986) developed a semi-empirical NTF model, as shown in eq 3.21. J N (S, T ) = J N ,max (T ) ⋅
SB,N K N + SB,N
(3.21)
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
Where J N ( S, T ) = NH3-N flux at SB,N (g/m2·d) and T; J N, max (T ) = maximum NH3-N flux at temperature T (g/m2·d); = JO2 ,max ( T ) 4.3 ; SB,N = bulk liquid NH3-N concentration (g/m3); KN = NH3-N half-saturation concentration (g N/m3) (1.0 to 1.5, typical value 1.0); and T = temperature (°C). Based on a “line-fit” relationship, the flux at any depth in the NTF can be calculated, as J N ( z , T ) = J N ( 0 , T ) ⋅ e − k ⋅z . Two solutions were developed to account for a change in the rate of nitrification with NTF depth (k ≠ 0) (eq 3.22), and the second assumes no decrease in the rate of nitrification with NTF depth (k = 0) (eq 3.23). a ⋅ J N ,max ( T )
k ⋅ vh
Sin , N ⋅ ( 1 − e − k⋅ z ) = Sin , N − SB , N + K N ⋅ ln SB , N
(3.22)
And, when k = 0, z ⋅ a ⋅ J N ,max ( T )
vh
Sin , N = Sin , N − SB , N + K N ⋅ ln SB , N
(3.23)
Where a = specific surface area (m2/m3); k = empirical parameter rate decrease (1/m) (= 0 to 0.16, typical value 0.1); vh = hydraulic load (with or without recirculation) (m3/ m2·d); z = NTF depth (m); and Sin,N = NH3-N concentration in influent stream (g/m3). These equations can be solved directly to size an NTF for a desired SB,N. When recirculation is used, an iterative solution routine, which includes eq 3.24, is required because of the effect recirculation has on both vh and Sin,N. SN , i =
S0 , N + R ⋅ S B , N 1+ R
or R =
S0 , N − Sin , N Sin , N − SB , N
(3.24)
where S0,N = ammonia-nitrogen concentration (g/m3) in the influent stream before being mixed with the recirculation stream.
123
124
Biofilm Reactors
The ammonia-nitrogen concentration in NTF influent stream, Sin,N, will be less than S0,N when recirculation is applied. Parker et al. (1989) proposed a modification of this model to account for oxygentransfer efficiency variability among modular plastic media types and operating conditions. The revised expression is as follows:
Where
J N ( z , T ) = EO2 ⋅
JO2 ,max ( T ) 4.3
⋅
SB , N K N + SB , N
(3.25)
EO2 = the dimensionless NTF media effectiveness factor and JO2 ,max ( T ) = maximum dissolved oxygen flux at temperature, T (g/m2·d). Gujer and Boller (1986) reported, based on their experience, an EO2 value in the range 0.93 to 0.96 for KS,O2 = 0.2 g O2 /m3 and the temperature range 5 to 25°C. Parker et al. (1989), on the other hand, observed lower EO2 values (in the range 0.7 to 1.0) and claimed that a departure from EO2 = 1.0 accounts for wetting inefficiency, biofilm grazing by macrofauna, or competition for dissolved oxygen between autotrophic nitrifying and heterotroph bacteria inside the biofilm. The researchers recommended that medium-density cross-flow media is used in NTF applications and that EO2 may range from 0.7 to 1.0 for such media. High-density cross-flow media had a corresponding EO2 approximately equal to 0.4 (Parker et al., 1995). Readers should note, however, that the basis for these observations was pilot-scale NTFs that continuously were fed influent wastewater through a nozzle-type system. No research exists describing the effect of rotary distributors and intermittent hydraulic application of influent wastewater on high-density media NTF performance. According to Parker et al. (1995), EO2 ⋅ JO2 ,max ( T ) 4.3 is the zero-order ammonianitrogen flux. The maximum dissolved oxygen flux reflects the oxygen-transfer efficiency of the selected modular plastic media, and was determined by the researchers with the TRIFL (Logan et al., 1987b). The coefficient KS,O2 determined for the Central Valley WWTP, Utah, was between 1 and 2 mg/L (Parker et al., 1989).
6.2.2 Okey and Albertson Nitrifying Trickling Filter Model Okey and Albertson (1989b) summarized nitrification rates observed from five different NTF facilities. These data were not corrected for temperature, and each of the trickling filters relied on natural draft ventilation; therefore, variability in the data may be the result of assignable causes also including wastewater characterization, media type, and hydraulic application rate. Okey and Albertson (1989b) suggest that
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
the NH3-N flux will approach 100% removal for loadings less than 1.2 g/m2·d. The empirical design procedure proposed by Albertson and Okey (1988) can be summarized as the sum of the medium-density NTF media for the zero- and first-order regions. The design procedure includes the following steps:
(1) Using eq 3.26, determine the trickling filter media volume based on zero‑ order kinetics using medium density (138‑m2/m3) media and an NH3-N flux (JN) of 1.2 g/m2·d over a temperature range of 10 to 30°C. Below 10°C, adjust the rate using Θ = 1.045(T-10). (2) Determine trickling filter media volume based on first-order kinetics using a rate (J’N), which equals the following formulation and does not have a temperature correction between 7 and 30°C: J = J ’ N
avg N
SN , e ⋅ SN , TRaN
0.75
g SN , e = 1.2 ⋅ d ⋅ m2 SN , TRaN
0.75
(3.26)
where SN,TRAN = a transition NH3-N concentration (mg/L), which can be determined from Figure 3.14. This concentration is dependent on the degree of oxygen saturation and temperature.
Ammonium-N Concentration, mg/L
10 9 8 7 6
Zero-order Region
5
Dissolved Oxygen 100% Saturation 75% Saturation 50% Saturation 25% Saturation
4 3 2 1 0
0
5
10
15
20
25
30
35
40
Temperature, °C
Figure 3.14 Transition NH3-N concentrations as a function of temperature (Okey and Albertson, 1989b).
125
126
Biofilm Reactors
The designer can determine the total trickling filter media volume by adding the volume required for both the zero- and first-order kinetic realms. The above design procedure stipulates that the following conditions are met: • Ratio of influent BOD5 to TKN concentrations ≤1.0, • Filtered BOD5 concentration ≤12 mg/L, • Q(1 + R) ≥ 0.54 L/m2·s (0.8 gpm/sq ft), • Carbonaceous BOD5 and TSS concentrations ≤30 mg/L for medium-density (138 m2/m3 [42 sq ft/cu ft]) synthetic media, • Mechanical ventilation is used, and • Distributor speed control to provide dosing rate in the range 25 to 75 mm/ pass and flushing intensity ≥300 mm/pass. The following illustrates application of the Gujer and Boller (1986) and Okey and Albertson (1989a) model. The following parameters were applied to define the NTF height required to process 219 530 m3/d (58 mgd) with a 9.4-mg NH3-N/L concentration (at T = 16°C) to meet the treatment object of 1.0 mg NH3-N/L remaining in the effluent stream: • Specific surface area, a = 138 m2/m3 (medium-density cross-flow modular plastic media); • Maximum ammonia-nitrogen flux at temperature T, JN,max = 1.1 g N/m 2·d (Gujer and Boller, 1986); • Total hydraulic load, vh = 65 m/d (35.2 to 88.0 m/d according to WEF, 2009); • Empirical nitrification rate decrease, k = 0 m/d (0 to 0.16, 0.11 typical when k > 0); and • Ammonia-nitrogen half-saturation coefficient, KN = 1.0 g N/m3 (Gujer and Boller, 1986).
6.2.2.1 Application of the Gujer and Boller Model Because the ammonia-nitrogen concentration is not reduced by a recirculation stream, and the influent ammonia-nitrogen concentration indicates that virtually no nitrification occurred in the secondary process, a high k-value is not expected, because the increased driving force, or bulk-liquid ammonia-nitrogen concentration, will promote oxygen rate-limiting conditions. Consequently, a zero-order ammonia-nitrogen
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
flux is expected. This condition is commensurate with a constant ammonia-nitrogen flux (i.e., the rate does not change, or k = 0). Therefore, rearranging eq 3.23, the following can be used to describe a total NTF height required to meet the treatment objective: Sin,N ⋅ Sin,N − SB,N + K N ⋅ ln a ⋅ J N,max (T ) SB,N g m 9.4 3 65 g g g hr m = ⋅ 9.4 3 − 1.0 3 + 1.0 3 ⋅ ln g gN m2 m m m 1.0 138 3 ⋅ 1.1 2 m 3 m m ⋅ d
Z=
vh
= 11.4 m In the event that k ≠ 0, eq 3.22 would be rearranged as follows:
1 Z = − ⋅ ln 1 − k
Sin,N k ⋅ vh ⋅ Sin,N − SB,N + K N ⋅ ln SB,N a ⋅ J N,max (T )
The total NTF cross-sectional area can be calculated based on the desired total hydraulic load, which, in this case, is assumed to be 80 m/d. area =
Q vh
m3 d = m 80 d = 3427 m 2 22 785
(3.27)
Next, the process designer must determine the number of NTFs and their dimensions. Assuming that the treatment objective can be met with eight equally sized NTFs operating in four parallel trains, the process will function as a two-stage system (i.e., NTFs in series). Then, the area of each NTF can be calculated as follows:
127
128
Biofilm Reactors
area =
Atotal N trains
3 427 m 2 4 = 857 m 2
(3.28)
=
Consequently, the area for each of the eight NTFs is 857 m2. Each of the circular NTFs will have a diameter calculated as follows: d=
or d=
π ⋅ d2 4
a⋅ 4 π
857 m 2 ⋅ 4 = π = 33 m (109 ft)
(3.29)
Because each of the four trains consists of two NTFs, the height (H) of each NTF can be calculated as follows: H = 11.4 m ÷ 2 = 5.7 m (18.75 ft) The media volume can then be calculated as follows: 3427 m2 × 11.4 m = 39 000 m3
6.2.2.2 Application of the Albertson and Okey Model The following parameters were applied to the Okey and Albertson (1989a) model, to provide a comparison for the process requirements defined using the Gujer and Boller (1986) model: • Transitional ammonia-nitrogen concentration in NTF, S N,TRAN = 3.0 g/m 3 (Figure 3.14, T = 16°C, and 75% saturation); and • Maximum ammonia-nitrogen flux, JN,max = 1.1 g/m2·d (consistent with the assumptions applied to the analysis above). First, calculate the biofilm area required to account for the zero-order region of the NTFs.
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
Q ⋅ (SN,i − SN,TRaN )
area =
J N,max
g g m3 ⋅ (24.4 3 − 3.0 3 ) d m m = g 1.1 2 m ⋅d = 4 330 078 m 2 222 785
Then, applying eq 3.26, the first-order flux can be calculated as follows:
J = J ’ N
avg N
SN,e ⋅ SN,TRaN
0.75
g 1.0 3 g m = 1.1 2 ⋅ g m ⋅d 3.0 3 m g = 0.48 2 m ⋅d
0.75
The biofilm area required to account for the first-order region of the NTF can be calculated as follows:
area =
Q ⋅ (SN,i − SN,TRaN ) J N,max
g g m3 ⋅ (3.0 3 − 1.0 3 ) d m m = g 0.48 2 m ⋅d = 923 346 m 2 222 785
129
130
Biofilm Reactors
Finally, the total biofilm area required in the NTF can be calculated as follows: area = area0− ord + area1st − order = 4 330 078 m 2 + 923 346 m 2
= 5 253 4224 m 2
The total NTF media volume can be calculated as follows: 5 252 424 m2 ÷ 138 m2/m2 = 38 068 m3 (1 343 811 cu ft). The surface area is fixed at 3427 m2, to maintain an 80-m/h total hydraulic load. In addition, the eight proposed NTFs will be operated as a two-stage process. Therefore, by fixing the total NTF surface area and assuming the use of four two-stage NTF trains allows for the determination of a total height required to provide the abovecalculated media volume: Height =
=
Volume area 38 068 m 3 3 427 m 2
(3.30)
= 11.1 m The height (H) of each NTF can be calculated as follows: H = 11.1 m ÷ 2 = 5.55 m (18.3 ft) Wall et al. (2001) compared the design procedures of Gujer and Boller (1986) and Okey and Albertson (1989a). Wall et al. (2001) concluded that both models generally provide a good description of NTF performance under average NH3-N loading conditions. However, the models generally showed more significant peaks and troughs than the samples indicated. The Gujer and Boller (1986) model predicted peaks that were more exaggerated than the Okey and Albertson (1989b) model. No justification was presented for the models’ inability to account for peak NH3-N loading conditions. Parker et al. (1995) demonstrated that the modified Boller and Gujer (1986) model (eq 3.25) effectively predicted NTF effluent NH3-N loading concentrations under both average and peak conditions. Example results of the study performed by Parker et al. (1995) are illustrated in Figure 3.15.
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
20
Ammonia - N, mg/l
Influent
10 Actual Effluent
0 25
31 October
5
10
15 November 1992
20
Predicted effluent
25
30
Figure 3.15 Actual and predicted effluent from an NTF (Parker et al., 1995). Predicted effluent was calculated using the modified Gujer and Boller (1986) model.
6.3 Temperature and Hydraulic Application Effects Two processes—mass transfer and biochemical conversion—are characteristic of all biofilm reactors and influence biofilm structure, function, and ultimately reactor performance. Mass transport of soluble substrates inside the biofilm is controlled by molecular diffusion, which is typically slow when compared with biochemical conversion. The resistance to mass transfer inside the biofilm results is strong soluble substrate concentration gradients (typically normal to the biofilm growth medium). The concentration gradients exist in the bulk liquid, near the biofilm surface, and inside the biofilm. Mass transport is the primary mechanistic difference between biofilm reactors, such as the trickling filter and suspended-growth reactors. Typically, full-scale operating suspended-growth systems are kinetically (i.e., biomass) limited, whereas biofilm reactors are diffusion (i.e., surface-area) -limited (Boltz and Daigger, 2010). Cold wastewater increases solubility (thereby increasing the rate of molecular diffusion), but a reduction in temperature also retards the rate of biochemical transformation. Temperature will have a substantial effect on trickling filter efficiency only if the biochemical transformation rate is less than the rate of molecular diffusion. Otherwise, soluble substrates simply will penetrate the biofilm deeper and support active biomass in a thicker (and/or denser) biofilm.
131
132
Biofilm Reactors
Benzie et al. (1963) observed that excessive cooling has a negative effect on BOD5 removal efficiency in carbon-oxidizing trickling filters, and Parker et al. (1990) observed a temperature effect on NTF performance. Benzie et al. (1963) reported that there was a significant difference in trickling filter BOD5 removal efficiency between the summer (mean temperature −4 to −1°C) and winter (mean temperature 19 to 23°C) months. In the trickling filter processes studied, where recirculation was practiced, a total seasonal variation of 35 to 40% in trickling filter BOD5 removal efficiency was reported, while only a 10% reduction in BOD5 removal efficiency was reported in a facility that did not recirculate (secondary clarifier effluent). The researchers concluded that a primary contributor to the marked reduction in performance during the winter months was the substantial cooling of wastewater resulting from recirculation. Parker et al. (1990) reported a temperature effect on NH3-N flux in NTFs for temperatures in the range 10 to 22°C. A key to good trickling filter performance is limiting temperature changes to a range over which temperature has little effect and minimizing heat loss during operation. Methods for reducing heat loss include the following: • Construct deep trickling filters with reduced cross-sectional area, to increase the WHL and reduce the recirculation flow; • Extend the containment structure upward so that it is 1.5 to 2.0 m above the distributor; • Cover the trickling filter; and • Provide a mechanical aeration system to control airflow (Grady et al., 1999). If a mechanical aeration system is not feasible, natural airflow can be controlled during the winter months with adjustable dampers on the vents and other air inlets. Optimal hydraulic requirements for promoting maximum nitrification rates are unknown. Gullicks and Cleasby (1986, 1990) and Okey and Albertson (1989b) presented data from studies indicating that increasing the application rate (L/m2·s) increased the rate of NH3-N oxidation. According to the researchers, hydraulic application rates greater than 1 L/m2·s (1.5 gpm/sq ft) produced the best results.
7.0 Design Considerations The following sections are related to equipment selection, specification, and trickling filter construction. The information described here is a guide, but it is recommended
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
that the final design result from the collaboration of discipline-specific specialists (e.g., mechanical, electrical, and structural engineers) and manufacturers’ technological specialists to completely define and evaluate a system design, interfacing, material integrity, and structural integrity test methods/tolerances.
7.1 Distribution System Methods of supplying wastewater to the trickling filter distributor include gravity feed, dosing siphons, and pumping. The type of conveyance process selected depends on the hydraulic gradient available and the distributor. Trickling filter distributors require piping between these conveyance systems and the trickling filter distribution system. Where the trickling filter is not designed for continuous dosing, a pump or dosing tank and siphon may precede the distribution system. Any type of trickling filter distribution system requires only a single conduit to convey wastewater. The hydraulic design of this conduit conforms to that for other WWTP process piping. Design variables include headloss, provision for drainage, structural considerations, and protection against applicable climatic and corrosive conditions. Flow distribution is an important feature in a trickling filter system. Wastewater influent to the bioreactor must be applied evenly at a rate that keeps the trickling filter media wet and prevents ponding and clogging. Uneven wastewater distribution and/or a dosing rate that is insufficient for biofilm thickness control will result in poor trickling filter performance. Odors will emanate as solids accumulate in the trickling filter, and biomass near the biofilm–growth-medium interface becomes anaerobic. Furthermore, insufficient biofilm thickness control promotes the accumulation of macrofauna. It is recommended that new trickling filters are constructed as circular tanks to accommodate the use of a rotary distributor. A rotary distributor may be equipped with 2 to 6 arms, but units with 4 arms are typical. The distributed flow may be staggered for full coverage per arm. That is, each arm may provide 50 or 100% coverage per revolution. Nozzles and dosing siphons are not recommended for systems treating municipal wastewater. Rotary distributors are the focus of material presented in this section. If a rectangular trickling filter is upgraded with a rotary distributor, special provisions should be made for wetting media that is outside of the distributor diameter. Otherwise, this media should be removed, or it will provide a breeding area for macrofauna. The need for and benefits of providing rotary distributor speed control has been discussed in the Distribution System section.
133
134
Biofilm Reactors
7.1.1 Hydraulic Drive Rotary Distributors Traditionally, hydraulically driven rotary distributor speed control is mediated by pumped water discharging from orifices situated along the trailing side of the distributor arms, as illustrated in Figure 3.16. Historically, little attention has been given (a)
Diameter
Thrust Bearing Stabilizing Bearing Support Cage
DC Drive 0.25 hp Center Mast Tie Rods
Barrel
Turnbuckle
Flush Gate
Tank wall
Square Arm Filter Media
Spreaders and Orifices
Braking Jet Spreader Locations
(b) Slip ring assembly Rotary distributor mechanism
Valve gate positioner typical (4) arms
Center cage
Air line drip leg typical (4) arms
Tie rods
Vent pipes Center wall
Fixed mast
Anchor bolts Center column
Influent feed pipe Influent flow
Tank wall Trickling filter media
Figure 3.16 (a) Typical hydraulically driven rotary distributor with reversethrusting jets and electric drive, and (b) modern hydraulically driven rotary distributor with variable-frequency controlled gates that close or open orifices (therefore, the flowrate contributes to reverse thrust) (Courtesy of WesTech HydroDoc™).
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
to the rotational speed of trickling filter distribution systems. As a result, typical dosing rates for these hydraulically driven rotary distributors were in the range 2 to 10 mm/pass at 0.2 to 1.5 rpm. These dosing rates are significantly less than those listed in Table 3.3. No minimum speed has been specified for a hydraulically driven rotary distributor. Trickling filters with hydraulically driven rotary distributors have reported stalling speeds varying from 4 to 20 min/rev. The modern hydraulically driven rotary distributor (e.g., HydroDoc [WesTech, Salt Lake City, Utah]) provides means for controlling the rotary distributor rotational speed using energy provided by the pumped influent wastewater. While traditional hydraulically driven distributors are rotated by the thrust of flow expelling flow from the back side of the distributor arms, modern hydraulically driven rotary distributors provide means to proportionally distribute flow between orifices in the front and rear of the distributor arm. Proportioned directional flow control provides rotational speed and, consequently, dosing rate control. Discharge orifices have spreaders that are placed along the front and rear walls of each arm. The orifices extend approximately 30% of the arm length. In front of each orifice row, a pivoting gate is placed against the wall inside the distributor arm. The front and rear gates are raised simultaneously and lowered in opposite directions (i.e., as the front gate closes, the rear gate opens). A gate linkage is designed to position the front and rear gates at their respective port centers at any point in time, which maintains consistent media coverage by maintaining the equivalent of full orifice area resulting from the sum of orifices along the front and back distributor arm. The gate is positioned by an air cylinder fit with a pneumatic controller that receives a 21- to 103-kPa (3- to 15-psi) signal, which represents a desired cylinder extension. The pneumatic position controller senses the degree of cylinder rod extension and directs air pressure to the appropriate end of the cylinder. The induced air pressure causes the cylinder to extend or retract, moving the sliding gates and controlling hydraulic thrust. When in position, pressure is applied to both sides of the cylinder to maintain the gate position indicated by the signaled air value. Control of the modern hydraulically driven rotary distributor consists of a programmable logic controller (PLC) or supervisory control and data acquisition (SCADA) system, which provides comparative monitoring between a feedback signal that describes the actual distributor arm rotational speed and an operator set point value defining the desired rotational speed. Based on the signal comparison results, a 4- to 20-mA signal is directed to the rotary distributor. This signal adjusts gate positioning, which either increases or decreases the rotational speed. The 4- to
135
136
Biofilm Reactors
20-mA signal from the PLC enters the system at the mast base and transmits through a conduit, which is positioned through the slip-ring assembly located at the top of the rotary distributor mast. The signal then passes downward through the air panel, where it is received by a current/power (I/P) transducer (which varies pressure and voltage). The I/P transducer converts the 4- to 20-mA current signal into a 21- to 103kPa (3- to 15-psi) pressure signal piped to the gate position controller located on each arm. Thereby, the I/P signal results in appropriate gate positioning. A feedback signal, indicating rotary distributor arm speed, originates from a rotary encoder, which is mounted below the slip-ring assembly (at the top of the mast). The encoder directs a signal that identifies (1) arm rotational speed and (2) rotational direction. The benefits to this mechanism include rotary distributor arm speed control and a zero-speed, which allows the operator to stop the mechanism for emergency shut down or maintenance (without waiting for the distributor arm to gradually decrease speed before stopping). Recommended operator-controlled PLC functions include the following:
(1) Local start/stop switch, (2) Speed display, (3) Zero-speed warning light and audio alert, and (4) Operator set point rotary distributor rotational speed.
Recommended algorithm-controlled functions include (1) PLC-based rotational speed settings predefined by the operator; or (2) programmed set points, which include the following: • Flushing start time = 0 to 23 hours, 0 to 59 minutes (hh:mm); • Flushing duration period = 0 to 23 hours, 0 to 59 minutes (hh:mm); • Normal operation rotary distributor rotational speed = 0 to 100% maximum speed; and • Flushing operation rotary distributor rotational speed = 0 to 100% maximum speed.
7.1.2 Electronic or Mechanical Drive Rotary Distributors Electrically driven rotary distributors may have a center or peripheral drive. Such an apparatus typically can be retrofitted easily at low cost. Like the PLC hydraulically driven rotary distributors, these units can be programmed to operate at varying dosing rates, as required, to optimize carbon oxidation, nitrification, and biofilm thickness control (which minimizes the accumulation of macrofauna and minimizes the odor
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
potential from anaerobic biofilms). The center-driven unit will be anchored to non-rotating parts of the influent structure, as shown in Figure 3.17. Where no upper steady bearing exists, bearing support must be installed with a stationary shaft, to provide a platform for the drive unit. This can be located in the mast support for the arm guy wires. Where an upper steady bearing does exist, the stationary shaft into this bearing assembly can be extended to support the drive assembly. A peripherally mounted electric drive can be used instead of a center drive. The traction drive can use the inside or
(a)
(c)
(b)
(d)
Figure 3.17 (a) Modern hydraulically driven rotary distributor, (b) gate controller, (c) orifices, and (d) full-length arm and distributor.
137
138
Biofilm Reactors
top of the wall. By spring-loading the drive wheel, it can operate with wall irregularities. A rotary union is used to transmit power. The arrangement is similar to that of a traction drive clarifier. It should be emphasized that hydraulic motors with equally wide speed ranges may be used instead of electrically driven units. Electrically driven rotary distributors with remote variable‑speed controllers and timers can operate independently of influent flow. This is may be advantageous for WWTPs without recycle flow or with sufficient recycle flow to minimize the rotational speed. However, the use of speed-controlled rotary distributors almost never replaces the need for a recirculation pumping station. The designer must carefully evaluate minimum flow conditions. Recirculation is typically applied, and the rotary distributor speed control is provided to increase operator flexibility, to optimize the trickling filter process performance.
7.1.3 Optimizing Rotary Distributor Operation Trickling filter optimization can be determined by adjusting the dosing rate and recording effluent water quality (after the system has reached a quasi-steady-state, with respect to effluent water quality). Flushing should be performed during the optimization process. The flushing ideally is conducted during low flow and loading periods, which likely occur between 1:00 a.m. and 6:00 a.m. If flushing has not been practiced, it may take several weeks of daily flushing to achieve proper biofilm thickness control. The optimum dosing rate can be determined by simultaneously operating trickling filters at different operating dosing rates, recording total and soluble BOD5 removal (and ammonia-nitrogen, if optimizing a carbon-oxidizing and nitrification trickling filter), and adjusting the individual trickling filter distribution speed accordingly. Daily high‑intensity flushing routines also can be programmed for the units, to define optimum flushing dosing rate and durations, to maximize trickling filter process performance. Once the optimum dosing and flushing rates have been defined, macrofauna accumulation will be minimized, and BOD5 removal and ammonia-nitrogen (if applicable) removal will be maximized.
7.2 Construction of Rotary Distributors Rotary distributor arms may be tubular or rectangular. Galvanized steel and aluminum are the most common construction materials. However, stainless steel may be used in corrosive environments. Influent wastewater distribution is accomplished with a series of orifices that are positioned along the distributor arm and cover 30 to 100% of the trickling filter (plan) area per pass. These orifices are equipped with manually or PLC
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
controlled sliding gates, and each orifice typically is equipped with splash plates, to further promote wastewater distribution. In many cases, distributors may be equipped with four arms in a high–low flow arrangement. Essentially, two of the arms operate at flows up to and slightly above the average design flow, while the remaining two arms operate only during peak flows. This generally is achieved by baffles that are inside the distributor arm and are near the trickling influent feed pipe. This arrangement maximizes wastewater distribution and flushing intensity, if practiced. The hydraulic head required to drive a distributor and provide influent wastewater distribution typically is in the range 410 to 1000 mm (16 to 40 in.) of water column. The head required for minimum flow typically is in the range 300 to 610 mm (12 to 24 in.) above the center line of the rotary distributor arm orifices. Somewhat greater head is needed to accommodate wide flow ranges. For some distributors, this head requirement has been reduced by the use of overflow devices, which result in dosing through additional arms during periods of high flow. Forcing flow through two arms aids in maintaining the flow through the orifices during minimum flow periods, which is required to maintain adequate wastewater distribution over the trickling filter surface. Trickling filter designs that operate with rotary distributor rotational speeds in the range 8 to 50 min/rev will exert negligible centrifugal force. Nevertheless, rotary distributors require a seal between the fixed influent column and the rotating section. Older designs have various types of water traps, mercury seals, or packed mechanical seals to prevent water from leaking between fixed and rotating parts. Modern designs use one of two types of seals. The first is an overflow arrangement without a lower seal. This type offers the advantage of no seal friction imposed on the mechanism and inherently no seal maintenance; however, the hydraulic head requirement is higher than the modern mechanical seal. Modern mechanical seals have a double neoprene seal with a stainless-steel seal ring; this seal also requires no maintenance and requires less hydraulic head than the aforementioned seal-free design. When older units are upgraded, improvements often include one of these arrangements.
7.3 Trickling Filter Media Selection The design engineer must make an informed decision regarding the selection of media for specific trickling filter applications, including the construction of new facilities and the retrofit of existing facilities. Guidance has been provided earlier in this chapter, but from a process performance perspective. This section describes mechanical considerations.
139
140
Biofilm Reactors
Drury et al. (1986) demonstrated that the increased specific surface area, ability to apply increased hydraulic loading, and capacity for improved biofilm thickness control make the replacement of rock media in existing trickling filters with modular plastic media advantageous. Because of the robust construction of containment structures that is required to support the structural load imposed by rock media, existing rock-media trickling filter containment structures may have their walls extended vertically. The taller trickling filter equipped with modular plastic media will result in expanded trickling filter capacity. The WWTP capacity is dependent on an evaluation of each unit process capacity, system hydraulics, and process mechanical appurtenances. Therefore, expanded bioreactor capacity does not necessarily imply that the WWTP capacity has been expanded. Replacing existing rock media with synthetic media may be warranted by a variety of conditions, which include odor generation, existing media deterioration, and treatment capacity expansion, while maximizing the use of existing assets in the existing footprint. Many trickling filter media types can be applied in a range of hydraulic and pollutant loading conditions and to a wide variety of wastewaters, including screened and degritted raw wastewater, primary effluent, secondary effluent, or industrial wastewater. Sufficient scientific evidence exists to surmise that cross-flow media produces better effluent water quality when compared with vertical-flow media, when treating wastewaters with low to medium total organic loading (Harrison and Daigger, 1987). However, if the total organic load becomes substantial, biofilm thickness control and other complicating factors lead to deteriorating effluent water quality. Therefore, vertical-flow media is recommended for roughing applications and the treatment of high-strength industrial wastewaters. Parker (1999) suggested that this efficiency change illustrates the switch-over effect (efficiency switch-over from cross-flow to vertical-flow media) at high total organic loads, which is not observed in the other studies. However, detailed studies do not exist that specify for which organic loading the cross-over originates. The previously described importance of adequate media-wetting and the relative inefficiency in media-wetting inherent to the trickling filter process has led some designers to combine modular plastic trickling filter media in a single bioreactor. The effect of combining trickling filter media is such that the cross-flow media, which is efficient in hydraulic distribution, is situated in the upper layers of the trickling filter, and vertical-flow media, which is less prone to excessive biofilm accumulation, constitutes the remainder of the trickling filter. The designer should note that the upper portions of trickling filters generally are subject to the highest organic load.
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
Numerous reports (Boller and Gujer, 1986; Crine et al., 1990; Gullicks and Cleasby, 1986, 1990; Onda et al., 1968; Parker et al., 1989) indicate that denser trickling filter media (e.g., random and cross-flow) are more prone to solids retention and fouling. Vertical-flow media is recommended for the treatment of high-strength (industrial) wastewaters, roughing applications, and wastewaters receiving only preliminary treatment (i.e., 3-mm fine screens and no primary clarifiers).
7.3.1 Depth Rock-media trickling filters in North America typically are 1 to 2 m (3 to 6 ft) deep, but may be as deep as 2.4 m (8 ft). The depth limitation of rock-media trickling filters typically is associated with inadequate ventilation (by natural draft) and propensity to pond. In Europe, deeper rock-media trickling filters are common; units in Arnheim, Netherlands, were constructed at 4.9 m (16 ft) deep, but were equipped with mechanical ventilation. There is a general absence of data comparing deep, mechanical ventilated rock-media trickling filters with shallow, natural draft rock-media trickling filters. Synthetic-media trickling filters commonly are constructed between 5 and 8 m (16 and 26 ft) deep, although units up to 12.8 m (42 ft) deep exist. Trickling filters in excess of approximately 9 m (30 ft) deep may require special provision to redistribute wastewater before reaching the bioreactor effluent plane. Factors limiting the depth of synthetic-media trickling filters include aesthetics, serviceability, pumping requirements, and structural integrity of the plastic media. Increased trickling filter depth has no implication on biological treatment efficiency. However, increasing trickling filter depth does reduce the minimum flow required to achieve optimal wetting efficiency (i.e., taller trickling filters generally have a smaller diameter, which is more susceptible to efficient wetting). The improved efficiency in wetting reduces recirculation pumping requirements. In taller filters that have high loadings, oxygen deficiency may occur in the uppermost layers. However, adequate ventilation and biofilm control measures can prevent problematic odors. The effect of trickling filter media depth on bioreactor performance has been treated as a matter of controversy in previous design manuals. Several investigators suggest that volume, regardless of depth, controls performance (Bruce and Merkens, 1970, 1973; Galler and Gotaas, 1964; Kincannon and Stover, 1982; National Research Council, 1946). Practical limitations placed on trickling filter performance generally are related to inefficiencies in media-wetting and physical constraints on trickling filter depth. Many of the investigators previously cited in this chapter (regarding the same topic) attributed the improved performance with trickling filter depth to
141
142
Biofilm Reactors
improved media-wetting. The average hydraulic rate should exceed 0.5 L/m2·s (0.75 gpm/sq ft) to ensure maximum performance.
7.3.2 Structural Integrity The choice of rock trickling filter media often is governed by the materials available locally or the cost of transportation. Field stone, gravel, broken stone, blast-furnace slag, and anthracite coal have been used for this purpose. Whatever material is chosen, it typically is specified that it should be sound, hard, clean, free of dust, and insoluble in wastewater constituents. There is some difference in opinion as to the optimum size of rock trickling filter media. A common specification requirement is that 95% or more of the media pass 2600-mm2 (4-sq in.) mesh screens and be retained on 1600-mm2 (2.5-sq in.) mesh screens. The pieces typically are specified to be uniform in size, with all three dimensions as close to equal as possible. The material should not disintegrate under service conditions, such as breaking into smaller pieces or crumbling into fine material. Frequently, the material is specified to be substantially sound, as determined by the sodium sulfate soundness test. Specifications for placing rock media frequently include statements such as the following:
(1) When placing trickling filter media, breakage and segregation of differently sized particles must be prevented; (2) Trickling filter media will be screened and cleaned immediately before placing, to eliminate as many fine sediments, or stone fragments, as possible; (3) Trickling filter media will be placed by a method that does not require heavy traffic of any type on the top of those media already placed; and (4) Placing media by means of belt conveyor, wheelbarrow, or bucket crane will be acceptable.
Synthetic trickling filter media, specifically the bundle type (0.61 m × 0.61 m × 1.22 m [2 ft × 2 ft × 4 ft]), are the most common media used in new trickling-filter-based WWTPs. Proper specifying and testing criteria should be used to ensure that the trickling filter media will satisfy duty requirements. Bundle media are manufactured from polyvinyl chloride (PVC), while the random media typically are manufactured from polyethylene or polypropylene. The testing procedures herein apply to bundle media, but it is equally important that the random media have sufficient strength to resist subsidence resulting from the combined weight of the media, water, and biomass. Consideration should be given to the long-term (96-hour) and short-term (typically <2-hour) test and the ability of either test to predict media strength over what
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
will hopefully be a minimum 20-year life. The PVC is suitable as a structural material, as long as deformation or creep loading is not exceeded. The material fails by deformation, which can be a slow process that persists if loading is maintained. New trickling filter media is stronger than 10-year-old trickling filter media, because PVC weakens with time. In addition, the plasticizer dissipates, and the media also becomes brittle. Because of the high initial strength-to-weight ratio, exceptionally thin media can meet inadequately drafted specifications and place long-term useful life in question. Typically, this is a problem of not understanding the relationship between short-term testing results and long-term load capacity. Test temperature is important, because PVC loses strength as the temperature exceeds 18 to 21°C (65 to 70°F). The load testing should be conducted at the maximum water temperature. The database temperature from media suppliers is 23 ± 1°C (73 ± 2°F); however, this 23°C temperature may not satisfy specific duty requirements. Mabbott (1982) not only introduced the short-term compression test to assess media strength, but also reported that the modulus of elasticity (and corresponding media strength) dropped drastically (with increased temperature). When temperatures of the wastewater exceed 30°C (86°F), all structural testing should be conducted at the maximum operating temperature of the media. The designer must carefully consider heat build-up coinciding with trickling filter shutdown and its effect on modular-plasticmedia structural integrity. The issue is amplified when trickling filters are covered by a dome where air may not easily escape the biological reactor. Aerobic biochemical reactions generally proceed within the temperature range 35 to 40°C, which is the upper limit for growth of mesophilic bacteria (Grady et al., 1999). These temperatures may be observed in activated sludge systems, but are not common operational temperatures for trickling filters. The pore (internal biofilm) temperature approaches equilibrium with the air temperature inside the trickling filter, which may be in the range 10 to 30°C. In addition to ambient conditions, the amount of biomass present, biomass condition, and mode of ventilation affect trickling filter internal temperatures (Harrison, 2007), which are important considerations during emergency shutdown or even during the installation of filter media. When procuring media, a good design practice is to specify a service temperature that exceeds the actual water temperature, to provide adequate protection during unplanned conditions. A service temperature of 32 to 49°C (90 to 120°F) would not be unreasonable for warmer climatic conditions, high organic loading rates, or for filters where partial plugging or temperature concerns exist. An alternative may be to provide rotary sprinklers within domed trickling filters for heat dissipation during shutdown periods—emergency or otherwise.
143
144
Biofilm Reactors
7.4 Trickling Filter Pumping Station or Dosing Siphon Most trickling filters use recirculation pumps, which typically are constant‑speed, low‑head centrifugal units designed to operate with a total head of the trickling filter media depth, 2.0 to 3.0 m of static head, and friction losses. The VFD-controlled motors currently are typical fixtures on process pumps. Both submerged and non-submerged (dry-pit) vertical pumps have been used extensively. Pump intake screens typically are unnecessary, because the recirculated flow typically is free of clogging solid materials. Hydraulic computations are necessary. Computations for minimum flow are necessary to ensure adequate head to drive hydraulically driven distributors; computations for maximum flow indicate the head required to ensure adequate discharge capacity. The net available head at the horizontal center line of the distributor’s arm and other points may be calculated by deducting the following applicable losses from the available static head: entrance loss; drop in level in the dosing tank, as distributor pipes are filled (only applicable to dosing siphons); friction losses in the piping to the distributor; proper allowance for minor headlosses; headloss through distributor riser and center port; friction loss in distributor arms; and velocity head of discharge through nozzles necessary to start the hydraulically driven rotary distributor. Trickling filter distribution head requirements are set by a system’s manufacturer. Despite the headloss resulting from the trickling filter commonly being the greatest in a given WWTP, power requirements for the trickling filter process (including recirculation pumping and auxiliary powered equipment) typically are less than those for the activated sludge process.
7.5 Control Mechanisms for Trickling Filter Macro Fauna Macrofauna and their larvae graze biofilm. Curds and Hawkes (1975) reported that grazing activity in full-scale trickling filters treating municipal and industrial wastewaters was affected by the nature of the biofilm and operational variables. Possible benefits associated with the presence of macrofauna include reduced sludge production, improved sludge settlability, and biofilm thickness control. Williams and Taylor (1968) conducted laboratory-scale experiments demonstrating that macrofauna-free systems transformed only 40% of the available organic carbon, with almost a complete absence of NH 3-N transformation. In contrast, macrofauna-containing systems converted approximately 90% of the organic carbon, and substantial nitrification occurred. Fauna respiration explains reduced biomass yield in the trickling filter process, suggesting that approximately 10% of the carbon dioxide produced in the trickling filter process results from macrofauna
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
(a)
(b)
Figure 3.18 (a) “Pouch” snail typically found in trickling filters treating m unicipal wastewater, and (b) a modular plastic media sheet with biofilm and s nail-grazing pathways. respiration (Curds and Hawkes, 1975). Solbe et al. (1967) found that the absence of macrofauna adversely affected trickling filter sludge settleability. During a 1-hour settling period, 34% of the solids settled compared with 68% when the macrofauna were present. On the other hand, trickling filter macrofauna may have the following detrimental effects:
(1) (2) (3) (4)
(5) (6)
(7) (8)
Grazing of nitrifying biofilm (Figure 3.18); Plugging of process piping; Damaging pumps; Damaging belts on gravity-belt sludge thickening and belt-press dewatering equipment; Organic snail bodies remaining in the effluent stream, which may exert BOD5; Shells remaining in the effluent stream, which may increase effluent fecal counts by shielding bacteria from disinfection processes; May exert additional solids loading on secondary sedimentation tanks; and May accumulate in aeration basins, thereby reducing aeration capacity and/ or efficiency in combined TF/SG processes (Figure 3.19).
7.5.1 Operational Strategies and Facility Improvements for Macro Fauna Control Several strategies have been applied to manage macrofauna accumulation and/or development in trickling filters, including physical, chemical, or a combination of
145
146
Biofilm Reactors
(a)
(b)
Figure 3.19 Snail shells covering fine-bubble diffusers in suspended-growth reactors that are located in (a) Pueblo, Colorado; and (b) Garland, Texas.
physical and chemical applications. The key is application of a condition that is either toxic to the animals or creates an environment not conducive to their accumulation. Lee and Welander (1994) demonstrated increased nitrification after predator control using substances toxic to eukaryotic organisms. The toxic substance must have no effect on, or only temporarily inhibit, beneficial microorganisms (Parker et al., 1997). Operators have conducted site maintenance, which aids in reducing macrofauna presence in trickling-filter-based WWTPs. For instance, some operators have observed that the presence of filter flies may be reduced simply by maintaining a short stand of grass on the WWTP site. More specific strategies include periodic high-intensity hydraulic application, trickling filter flooding, pH adjustment with lime or sodium hydroxide, high-concentration ammonia dosing, trickling filter humus screening or accelerated gravity separation, gravity separation in low-velocity channels with a dedicated pumping circuit, eliminating dissolved oxygen from the trickling filter feed, adding salt, draining and freezing the infested unit, raising the temperature quickly, adding molluscicide (e.g., copper sulfate), and chlorinating the trickling filter’s influent stream. Many of these strategies have proven ineffective in some trickling filters, and others may be detrimental to trickling filter performance. Biochemical reactions are influenced, to some degree, by temperature, pH, and alkalinity; adjusting these parameters may inhibit the biochemical reactions and lower transformation rates. Chemicals, such as chlorine, are toxic to all organisms in the trickling filter and may result in the destruction of
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
sensitive biomass (Parker et al., 1989). Control mechanisms reviewed here include the following: • Periodic high-intensity hydraulic flushing (Spülkraft), • Trickling filter flooding and chemical application, • Chemical treatment (focus on high concentration NH 3-N dosage and pH adjustment with sodium hydroxide), • Trickling filter effluent or underflow (humus) screening or accelerated gravity separation using equipment typically associated with grit removal, and • Gravity separation in low-velocity channels and removal with a dedicated pumping circuit.
7.5.2 Spülkraft Spülkraft is the instantaneous dosing intensity as a function of distributor speed (ATV, 1983). Slowing distributor rotation increases the instantaneous dosing intensity and increases flushing, which removes excess biomass and helps to control macrofauna, while increased distributor rotation increases the wetting efficiency and improves the treatment efficiency. When mechanical distributor speed control—with an electrically driven rotary distribution mechanism, for example—is used, the definition of Spülkraft may be inverted to calculate the rotational speed required to achieve flushing intensity. The optimum Spülkraft is to be defined and, to a degree, may be siteand application-specific. If applied, the flushing Spülkraft period typically is 5 to 10% of the 24-hour period and will operate at 6 to 15 times the routine operating Spülkraft, which emphasizes the need for a significant range in rotational speed control. Those WWTPs retrofitted with distributor speed modulation initially may observe (2 to 10 weeks) higher settled trickling filter effluent BOD5 and TSS, as these sloughed solids are not readily settleable. This is similar to sloughing cycle effects that are common to many trickling filter facilities (Albertson, 1995). Hawkes (1955, 1963) demonstrated that high hydraulic loadings and instantaneous dosing rates can control filter fly development. As illustrated in Figure 3.20, increased hydraulic loading improves trickling filter media-wetting efficiency, reducing trickling filter media dry spots and eliminating ideal spawning areas for filter flies. Gujer and Boller (1984) reported that filter fly larvae were reduced, to quantities that did not have an effect on the NTF process, by hydraulic application. The THL must be sufficient to guarantee complete media-wetting. Pilot-scale NTFs, with a medium-
147
148
Biofilm Reactors
Interval of Distributor 1–5 minutes 400
Rotation
30–55 minutes
Film
300 Organic Matter 200 g/cu ft 100 0
Anisopus (Fly)
40
20 0
Psychoda (Fly)
Organisms 30 103/cu ft 20 10 0
Lumbricilus (Worm)
10 0
Jan Jan Jan Jan Jan Jan 1952 1953 1954 1955 1952 1953 1954 1955
Figure 3.20 Biofilm and filter fly control with low-frequency dosing (cu ft × 0.028 32 = m3) (Hawkes, 1963).
density cross-flow media and fixed distributors, required a THL of 3 m/h. Grady et al. (1999) later reported that adequate media-wetting may be achieved at THLs of 1.8 to 2 m/h, with rotary distributors. In contrast, Andersson et al. (1994) tested three flushing intensities (SK values of 5, 40, and 80 mm/pass) and reported that the variable flushing intensity had no apparent effect on filter flies and worms in a pilot-scale NTF.
7.5.3 Flooding Trickling filter flooding requires adequate duty units to isolate a trickling filter for a period of 3 to 6 hours. The trickling filters must be designed as water-retaining structures, which is not typical and represents a small fraction of existing trickling filters.
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
Variations include (1) saline flooding, and (2) flooding and backwashing with an alkaline solution. Parker et al. (1997) reported the use of flooding to control filter flies and an alkaline backwash process to control other macrofauna in two 32-m diameter, 7.3m-deep, medium-density XFM NTFs at the Littleton-Englewood WWTP, Colorado. Online pH probes and a sodium hydroxide metering system allow for flood water pH adjustment by set point. The alkaline flood water is pumped in through the bottom of the NTFs, discharges into an overflow trough, and then is directed to the head of the WWTP for treatment. Alkaline treatment is reported to have removed 76% of the larvae at pH 9 and 99% at pH 10 (Parker et al., 1997). Subsequent research trials designed in response to full-grown snail development showed that flooding and backwash (4 hours at pH 9) reduced the snail quantity by two-thirds and returned the NTFs to high nitrification efficiency (Parker, 1998).
7.5.4 Chemical Treatment Everett et al. (1995) summarized several chemical treatment alternatives, including pH adjustment and chlorination, sodium chloride, and molluscicides (e.g., copper sulfate, metaldehyde, niclosamide, and trifenmorph). Factors such as pH, turbidity, and molluscicide dose are key in determining the chemicals’ application rate. Rotating biological contactors (RBCs) in Lafayette, Louisiana, applied sodium chloride at a dosing concentration of 10 mg/L for a 24-hour period, to effectively control the snail population. Calcium hypochlorite at 60 to 70 mg/L for a 2- to 3-day period effectively controlled snails in RBCs at the Deer Creek WWTP, Oklahoma City, Oklahoma. Copper sulfate at low concentrations (0.45 kg of copper sulfate per 3.785 m3) may effectively control snail accumulation. Ammonia is toxic to snails (Arthur et al., 1987). Lacan et al. (2000) conducted a laboratory-scale study and plant-scale application of undissociated aqueous ammonia (NH3-N(aq)) solutions with elevated pH to control snail growth (P. gyrina) in NTFs. Undissociated aqueous NH3-N(aq)—not the ammonium ion—is the snail P. gyrina toxophore. The concentration producing 100% mortality is a function of exposure time and the bulk-liquid NH3-N(aq) concentration. The laboratory-scale study demonstrated that an ammonium chloride (NH4Cl) solution at pH 9.2 (NH3-N(ag) = 150 mg N/L) resulted in 100% snail mortality. A much higher concentration of ammonia in a trickling filter’s influent stream (1000 to 1500 mg N/L) is necessary in practice to maintain the required NH3-N(ag) = 150 mg N/L because of the immediately reduced concentration resulting from axial dispersion, biofilm diffusion (both external and internal), and biochemical reaction (according to trickling filter bioreactor
149
150
Biofilm Reactors
hydrodynamics). Lacan et al. (2000) estimated that an influent ammonia concentration of 1080 mg N/L resulted in an average concentration throughout the NTF of 185 mg N/L. Such a high-concentration NH3-N(aq) stream may be readily available in municipal WWTPs as solids processing recycle streams. In some cases, however, it may be necessary to purchase NH3-N(aq). The first full-scale application of this snail-control method was reported by Gray et al. (2000) at the Truckee Meadows WWTP, Reno Sparks, Nevada, which uses highdensity (215 m2/m3) media. Ammonia-rich anaerobic digester centrate was directed to an NTF recirculation pumping station. Sodium hydroxide was added to the recirculation stream to raise the pH to 9.05 (range between 9.0 and 9.5), which increased the NH3-N(aq) content of the centrate solution. Applied once per month, during application, an NTF is isolated, and the solution is recirculated through the trickling filter for approximately 2 hours. The first 20 to 50 minutes is dedicated to reaching hydrodynamic steady-state, and the remainder is the minimum recommended exposure time for 100% mortality of both adult snails and their larvae. The treatment solution is returned to the head of the WWTP after dosing is completed, and the NTFs then are flushed with secondary effluent in the “recirculation mode” for 10 hours. Figure 3.21 illustrates these operating modes. Periodic grab samples or online monitoring during the flushing cycle is necessary to ensure that the effluent NH3-N concentration is less than or equal to the influent concentration before the NTFs were returned to service. Lucero et al. (2002) observed that a similar procedure on carbon-oxidizing trickling filters required less than 8 hours. Lacan et al. (2000), who reported that the use of ammonia for snail control also has been applied to carbon-oxidizing trickling filters, suggested that the abovedescribed procedure will not produce deleterious effects in the carbon-oxidizing trickling filters because of the lower sensitivity of the heterotrophic bacteria to pH and NH3-N and more expedient regeneration of the heterotrophic biofilm. Rather than a reduced flushing period, it may be possible to eliminate the 10-hour backwashing step, if the carbon-oxidizing trickling-filter-based WWTP is not subject to NH3-N permit limitations and has typical pH discharge standards of “6 to 9” (Lacan et al., 2000). Lucero et al. (2002) applied this snail-control operation to combined carbon-oxidizing and nitrification trickling filters in a TF/SC process at the Duck Creek Wastewater Treatment Center, Garland, Texas. The TF/SC process returned to full nitrification capacity after a period of declining performance, subsequent to snail treatment. Diminishing nitrification performance because of an inhibitory substance in the raw wastewater was reported later.
Nitrifying TF Normal Operating Mode
C
To Headworks C C Centrate Sodium C Hydroxide
OO OO Secondary Effluent TF Effluent
O
C O
C Recirculation Pump Station
Nitrifying TF Centrate Treatment/Recirculation Mode
C OO
C
OO Secondary Effluent TF Effluent
C
O C
To Headworks O Centrate Sodium O Hydroxide
O Recirculation Pump Station
Nitrifying TF Flushing Mode
O OO OO Secondary Effluent TF Effluent
O
C C
C
To Headworks C Centrate Sodium C Hydroxide
O Recirculation Pump Station
Legend O = Open Valve C = Closed Valve = Operating Flow Path
Figure 3.21 Nitrifying trickling filter operating modes for high-concentration undissociated aqueous ammonia dosing (Lacan et al., 2000).
151
152
Biofilm Reactors
7.5.5 Physical Control Physical removal techniques described here include the following:
(1) Trickling filter effluent or underflow (humus) screening, (2) Gravity separation in low-velocity channels and removal with a dedicated pumping circuit, and (3) Accelerated gravity separation using equipment typically associated with grit removal.
The Central WWTP, Baton Rouge, Louisiana, uses trickling filter secondary clarifier underflow screening to control snail accumulation in, or damage to, solidshandling equipment. Through a series of statistical analyses, Lin and Sansalone (2001) found that snail infestation in another trickling-filter-based WWTP in Baton Rouge, Louisiana, did not affect BOD5 removal efficiency in carbon-oxidizing trickling filters. However, snail shells filled gravity-thickening tanks, plugged sludge process piping, and damaged belts in sludge thickening and dewatering equipment. A structure containing parallel static screens subsequently was erected, with underflow pumps directing the trickling filter humus through them. Snail shells are retained by the screens and fall by gravity into a collection bin for disposal. Waste sludge flows through the screens to sludge thickening. Although effective in protecting biosolids handling equipment, the system is reported to be a source of odor. The City of Lawton, Oklahoma (49 000 m3/d) and both the South San Luis Obispo, California, County Sanitation District Oceana Regional Plant (19 000 m3/d) and the City of San Luis Obispo Water Reclamation Facility, San Luis Obispo, California (9000 m3/d), pump trickling filter secondary clarifier underflow to a free vortex classifier for snail shell removal. Each of these systems is reported to prevent excessive snail shell buildup in digesters. The units remove approximately 0.69, 0.076, and 0.23 m3 snails/d, respectively (Neumayer, 2002). The Econchate Water Pollution Control Plant in Montgomery, Alabama, removes snail shells remaining in the secondary effluent, which were shielding pathogens from chlorine disinfection. The chlorine contact basin was modified to a two-pass channel, to serve as a low-velocity sedimentation basin for snail shells escaping secondary clarification. The snail shells deposited in the low-velocity channel are collected in a sump and pumped through a static screen, where they fall, by gravity, into a collection bin. The wastewater is returned to the chlorine contact basin for disinfection and final disposal.
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
Tekippe et al. (2006) reported the use of baffles, grit pumps, and classifiers to remove snails from the Ryder Street WWTP, Vallejo, California. The facility treats wastewater with a TF/SG process consisting of two 32-m-diameter and 7.3-m-deep XFM trickling filters. The trickling filters were reported to produce snail shells in quantities that hindered aeration basin diffuser performance, requiring both the aeration basins and the secondary clarifiers to be taken out of service for cleaning and maintenance. The Spülkraft was ineffective to control snail accumulation in the trickling filters. The properties of the snail shells were found to be similar to grit— essentially light enough to be pumped by conventional centrifugal pumps. A small portion of the snails have air entrained in their shells, and others may be disconnected from their shell, so a fraction of the snails in a trickling filter effluent may float or be neutrally buoyant. The influent of the Ryder Street WWTP’s aeration basins subsequently was improved to provide a zone for the majority of the shells to settle and an automatic mechanism to remove the settled shells (Tekippe et al., 2006). Redwood baffles were inserted to the basin entrance to distribute inlet velocity and others downstream to contain the snail shells in the first 6 m of the rectangular aeration basins. The basin floor was sloped to prevent snail shell accumulation in the corners and direct the snails to a sump, and the aeration system in this region of the basins was modified to promote settling, with a rolling flow pattern similar to that in an aerated grit removal chamber. The shells then are conveyed, via grit pump, to a grit cyclone and classifier system adjacent to the aeration basin influent pumping station. The classifier discharges to a bin, and the shells are transported to final disposal. Tekippe et al. (2006) reported that, while the system removed approximately 49 000 m3/d during the first few days of operations, since startup, the quantity of shells stabilized to approximately 1.53 m3/d.
7.6 Trickling Filter Startup Understanding the formation sequence and composition of the biofilms that grow in trickling filters will aid designers in making well-informed decisions regarding process optimization, design, startup, and emergency shutdown. The phylogenetic composition of mature trickling filter biofilms is defined by their development and life-cycle processes. On a time series, trickling filter biofilm development follows an S-shaped curve, or sigmoidal function, and can be divided into (1) initial activities, (2) exponential accumulation, and (3) steady-state (Characklis and Marshall, 1990). Biofilms exist in cycles that include transport and adsorption of organic molecules to the substratum (surface conditioning); transport and attachment of microbial cells
153
154
Biofilm Reactors
to the surface of the trickling filter media (formation); bacterial transformation processes (biofilm growth and extracellular polymeric substance [EPS] excretion); and partial biofilm detachment, as a result of fluid shear stress (Trulear and Characklis, 1982). The initial process of organic layer adsorption occurs within minutes of initial exposure of the clean surface to the wastewater stream. Baier (1973) conducted studies demonstrating that this initial adsorption is a prerequisite to biofilm formation because of the substratum-conditioning effect. Bacterium transport to the substratum is dependent on the bulk liquid flow regime. Some of the bacteria are reversibly attached, and, as a result, some of these cells are detached as a function of trickling filter hydrodynamics. Others remain and become irreversibly attached. The irreversibly attached cells use bulk liquid substrate and nutrients. This is a continual process, in which its rate is best defined by reactions kinetics post-biofilm formation. The attachment process is promoted by the presence of EPSs. The irreversibly attached bacteria then produce EPSs, which bioflocculate other bacterial cells and particulate matter (both organic and inorganic), which accelerates biofilm formation—hence the presence of an exponential biofilm formation phase. Thörn et al. (1996) performed pilot-scale investigations on NTFs treating municipal wastewater. A portion of the researchers’ results are illustrated in Figure 3.22. Similarly, Biesterfeld and Figueroa (2002) investigated autotrophic nitrifying biofilm development on glass slides in fullscale NTFs treating municipal wastewater. Thörn et al. (1996) observed virtually identical nitrifying biofilm formation/maturation periods for two media densities. The investigation of Biesterfeld and Figueroa (2002) improved on the other study by measuring these parameters at different trickling filter depths, rather than apparent rates measured for the entire bioreactor. Although the rates are different in each zone, the trends are comparable. Nitrification may be observed after 1 month. However, these investigations suggest that the maximum transformation rate occurs between 2.5 and 3 months. Interestingly, there is an increase in observed biomass accumulation before obtaining the maximum transformation rate for the system or zone. Then, the biomass diminishes slightly when the maximum transformation rate is approached. The decrease is attributed to biofilmdegrading processes, such as grazing, sloughing, and bacterial hydrolysis. Nitrifying biofilms develop at a much slower rate than carbon-oxidizing biofilms. The heterotrophic bacteria that constitute the carbon-oxidizing biofilm will demonstrate removal after only days, but there is little comparative evidence that allows for the definitive assignment of a trickling filter carbon-oxidizing biofilm formation period. Stenquist et al. (1974) observed that a pilot-scale, synthetic media, combined carbon-oxidizing
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
Nitrification rate, g N m–2 d–1
2 157 m2 m–3 226 m2 m–3
1.5 1 0.5 0 –0.5
0
20
40 60 80 100 120 Time after start-up, days
Dry weight
Bacterial count 8 1011 7 1011
35 30
6 1011 5 1011 4 1011
25 20 15 10
3 1011 2 1011
5
1 1011
0
0
20
40 60 80 100 120 Time after start-up, days
Bacterial count
Dry weight, g m–2
140
0 140
Figure 3.22 Nitrification rate and biomass accumulation in pilot-scale NTFs after startup (Thörn et al., 1996).
and nitrification trickling filter treating high-strength cannery wastes achieved fairly steady BOD5 removal rates only 1.5 weeks after startup. Little evidence exists to support the concept of accelerated biofilm formation promoted by seeding trickling filters with activated sludge. In fact, the competition for substrate between the suspended flocs in the bulk liquid and the forming biofilm may retard the biofilm’s developmental process.
7.7 Combined Trickling Filter and Suspended-Growth Processes Biological processes, including both a trickling filter and suspended-growth reactor, build on the known performance and operating characteristics of the parent processes. Numerous combinations of TF/SG processes are possible and are influenced by the
155
156
Biofilm Reactors
type of parent process used, loading to the treatment units, and the point at which biological or recycle sludge is reintroduced to the main flow stream (Harrison et al., 1984). Most combined TF/SG processes use a biofilm reactor in series with an SGR and a secondary clarifier. The systems can be classified by their suspended-growth component. When the SGR is used primarily as a bioflocculating system, with limited oxidation of soluble organic matter, the unit is referred to as the TF/SC process. All other TF/SG processes use the SGR as a substantial oxidizing unit. If a relatively small trickling filter is used, then a larger SGR is required (Grady et al., 1999). The capacity to which each of the units is designed is largely an economic tradeoff. Trickling filters are known for their energy efficiency, low maintenance requirements, and ability to resist shock loads. Designers have found that combining the shock resistance of a trickling filter with suspended-growth processes known for producing high-quality effluent often can yield better results than using only one of the two parent processes. Commonly used TF/SG processes typically are classified by those that have low to moderate organic loadings to the trickling filter versus those with high organic loads (e.g., roughing trickling filter). The typical TF/SG process schematic in Figure 3.5 illustrates common methods for returning secondary sludge, with or without reaeration. Designers use separate terms to differentiate process modes. When an intermediate clarifier is used, the process typically is considered to be a staged system; that is, the processes are not directly coupled. Common modes for dual processes are described below. Table 3.5 lists generally accepted design criteria for various TF/SG processes.
7.7.1 Activated Biofilter The activated biofilter (ABF) process uses a moderately loaded, with respect to organics, trickling filter. Modular plastic or redwood media must be used in the ABF trickling filter component (rather than rock), because return sludge is incorporated to the primary effluent and recycled over the trickling filter media. Some designers have concluded that improved sludge settleability occurs with the ABF. One theory as to why the benefit of a lower sludge volume index (SVI) occurs is that the high foodto-microorganism ratio and dispersed plug-flow of the trickling filter allows heterotrophic bacteria to be more competitive than filamentous bacteria. Bacterial selection occurs as a result. Although it performs well at low organic loads, the ABF process typically has been unsuccessful at consistently achieving effluent water quality, within tolerances (imposed by regulatory agencies) that would merit the selection of a trickling-filter-based process (i.e., concentrations less than 30 mg BOD5 or TSS/L) at organic loads of 0.9 to 1.6 kg BOD5/m3∙d (60 to 100 lb BOD5/d/1000 cu ft). The TF/ SC process allows for high-quality effluent with trickling filter total organic loading
Table 3.5 Design criteria for selected combined TF/SG processes (lb/d/1000 cu ft × 0.016 02 = kg/m3∙d; gpd/sq ft × 0.001 698 4 = m/h).* Design criteria Parameter
Range
Common
Activated biofilter (plastic media) Solids production (mg VSS in waste/mg BOD5 removed)
0.7 to 0.9
0.7
ABF hydraulic load (m /m ·d) (gpm/sq ft)
47 to 293 (0.8 to 5.0)
82 (1.4)
Trickling filter influent total organic load (TOL) (lb/d/1000 cu ft)
10 to 75
30
Sedimentation basin overflow rate at average day flow (m /m ·d) (gpd/sq ft)
33 to 49 (800 to 1200)
41 (1000)
Underflow concentration (% total solids)
0.6 to 1.2
1.0
Solids production (mg VSS in waste/mg BOD5 removed)
0.7 to 0.9
0.7
Trickling filter hydraulic load (m /m ·d) (gpm/sq ft)
5.9 to 117 (0.1 to 2.0)
59 (1.0)
Trickling filter influent total organic load (TOL) (lb/d/1000 cu ft)
20 to 130
80
Solids contact basin side water depth (m) (ft)
3.7 to 6.1 (12 to 20)
4.9 (16)
Solids contact basin HRT at average day flow (minutes)
10 to 60
45
Solids contact basin HRT at peak flow (minutes)
10 to 60
20
Solids contact basin SRT (days)
1.0 to 2.0
1.5
3
2
3
2
Trickling filter/solids contact (modular synthetic media) 3
2
Solids contact basin mixed-liquor suspended solids concentration (mg/L) 1.5k to 3000
2200
Sedimentation basin overflow rate at peak flow (gpd/sq ft)
1.2k to 1800
800
0.6 to 1.2
0.8
Solids production (mg VSS in waste/mg BOD5 removed)
0.8 to 1.2
1.0
Trickling filter hydraulic load (m /m ·d) (gpm/sq ft)
47 to 293 (0.8 to 5.0)
1.0
Trickling filter influent total organic load (TOL) (lb/1000/d/cu ft)
75 to 300
150
Aeration basin side water depth (m) (ft)
3.7 to 6.4 (12 to 21)
18
Aeration basin HRT at average day flow (minutes)
30 to 240
120
Aeration basin HRT at peak flow (minutes)
10 to 40
30
Aeration basin SRT (days)
1.0 to 8.0
3.0
1.5k to 6000
2500
Sedimentation basin overflow rate at average day flow (m /m ·d) (gpd/sq ft)
20.4 to 40.74 (500 to 1000)
32.6 (800)
Underflow concentration (% total solids)
0.6 to 1.2
0.8
Underflow concentration (% total solids) Trickling, roughing, or biofilter/activated sludge (plastic media) 3
2
Aeration basin MLSS concentration (mg/L) 3
2
* Values are valid for circular flocculator clarifiers with rapid sludge withdraw.
157
158
Biofilm Reactors
of 150 to 200% of these values. Therefore, the ABF typically is dismissed as an inferior biotechnology. Furthermore, in cold-weather climates without short-term aeration, the ABF process has proven incapable of maintaining good performance. To overcome these problems, the ABF system later was modified to include a relatively small aeration basin, which collectively has been called the biofilter/activated sludge (BF/AS) section (Harrison and Timpany, 1988).
7.7.2 Trickling Filter/Solids Contact A majority of organic matter in municipal wastewater is colloidal or particulate material (Boltz and La Motta, 2007; Levine et al., 1985, 1991). Like most biofilm reactors, trickling filters are poor bioflocculating systems (Boltz et al., 2006). Therefore, the TF/SC process operates under the premise that trickling filter effluent contains a high concentration of not readily settleable colloidal and particulate organics. This material may be removed from the trickling filter effluent stream by bioflocculation in a solids contact basin (La Motta et al., 2004). The entrapped particulate and colloidal organics are hydrolyzed or removed from the biological process with the wasted biomass. The TF/SC process includes the following:
(1) A rock- or modular plastic-media trickling filter; (2) An aerated solids contact basin and/or return sludge or underflow, reaeration tank; and (3) A circular flocculator-clarifier capable of rapid sludge withdrawal.
The U.S. EPA (in a report prepared by Matasci et al., 1986) described the following distinguishing characteristics of the TF/SC process: • The majority of soluble BOD5 removal occurs in the trickling filter; • Return sludge is mixed with trickling filter effluent rather than primary effluent; • A solids contact basin functions to promote the bioflocculation of dispersed solids remaining in the trickling filter effluent stream (i.e., solids capture); • The solids contact basin SRT is less than 2 days; • The solids contact basin aerobic hydraulic retention time (HRT) is 1 hour or less based on total flow (including recycle); and • The solids contact basin is not designed for nitrification, although it may occur as a result of nitrifying biofilms growing in the trickling filter, detaching, and
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
essentially bioaugmenting the suspended biomass inventory that has accumulated in the solids contact basin. A solids contact basin typically is 5 to 20% of the volume that would be required with equivalent treatment by activated sludge alone. There are three modes of operating the TF/SC process—mode I, mode II, and mode III. Mode I relies exclusively on the solids contact basin for colloidal and particulate organic matter bioflocculation and the oxidation of residual soluble organic matter. Mode II relies exclusively on a return sludge aeration tank. After aeration, the aerated return sludge is mixed with trickling filter effluent for colloidal and particulate organic matter bioflocculation. Mode III makes use of both the solids contact basin and a return sludge aeration tank. A typical TF/SC process operates as mode I, but, as of 2001, more than one-half of the TF/SC-based WWTPs operated as mode III (or have the operational flexibility to operate as modes I or III). It should be noted that mode II seldom is used and typically is not recommended, as it does not have a solids contact basin and only a sludge reaeration tank. The TF/SC mode I typically is used when there is a high trickling filter TOL, which results in the potential for significant soluble BOD5 breakthrough to the solids contact basin. The use of a sludge reaeration tank in TF/SC mode III allows WWTP operators to sustain an increased biomass inventory, which accommodates a higher SRT, dampens the effects of inaccurate sludge wasting, and reduces the potential for suspended biomass washout during wet-weather events (Parker and Bratby, 2001). These operational modes are illustrated in Figure 3.23. Rock-media trickling filters in the TF/SC process have been demonstrated to be capable of processing TOLs up to 0.4 kg BOD5/m3·d (25 lb BOD5/d/1000 cu ft). Matasci et al. (1988) demonstrated that a TF/SC process incorporating a rock-media trickling filter produced average effluent suspended solids and BOD5 concentrations of 19 and 15 mg/L, respectively, at a 0.9-kg BOD5/m3·d (55-lb BOD5/d/1000 cu ft) TOL. The TF/SC processes, which include a modular plastic-media trickling filter, also have been demonstrated to be capable of processing a higher TOL than reported for the trickling filter process. Parker and Bratby (2001) stated that a TOL in the range 0.2 to 2.1 kg BOD5/m3·d (20 to 130 lb BOD5/d/1000 cu ft) may be applied to cross-flow media trickling filters in the TF/SC process. The lower end of this range refers to combined carbon oxidation and nitrification trickling filters. Suspended solids remaining in the effluent stream are expected to increase with increasing TOL on the cross-flow media trickling filter. Significant odor potential exists for TOLs on
159
160
Biofilm Reactors
Trickling filter Aerated solids contact tank
Secondary clarifier
Flocculator center well
Mixed liquor
Treated effluent
Primary effluent Return sludge
Waste sludge
TF/SC Mode I – Solids Contact Trickling filter Secondary clarifier Mixed liquor Primary effluent Waste sludge
Flocculator center well Treated effluent
Return sludge
TF/SC Mode II – Reaeration Trickling filter Aerated solids contact tank
Secondary clarifier Mixed liquor
Primary effluent Waste sludge
Flocculator center well Treated effluent
Return sludge
TF/SC Mode III – Solids Contact/Reaeration
Figure 3.23 Three modes of TF/SC process operation (after Parker and Merrill, 1984). c ross-flow media trickling filters in the range 1.3 to 1.8 kg BOD5/m3·d (80 to 110 lb BOD5/d/1000 cu ft). In context of the TF/SC process, the TOL that results in substantial odor generation from a rock-media trickling filter must be evaluated on a site-specific basis. The threshold for substantial odor generation may establish the upper limit TOL for a specific application. Covers, ventilation, and captured air treatment are recommended for trickling filters receiving a high TOL. Inadequate research
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
exists to demonstrate that the TF/SC process is capable of withstanding shock loads or that the process exhibits characteristic reliability and robustness when receiving a greater TOL. Solids contact basin HRT typically is in the range 10 to 60 minutes. Parker and Bratby (2001) reported that a minimum 2.0-mg/L bulk-liquid dissolved oxygen concentration has served as a design guide. La Motta et al. (2003) demonstrated that the suspended solids concentration remaining in the TF/SC process effluent stream at the Marrero WWTP (Marrero, Louisiana) was reduced when the air-induced velocity gradient was minimized. The researchers replaced existing coarse-bubble diffusers with fine-bubble diffusers and controlled the bulk-liquid dissolved oxygen concentration in the range 1.0 to 1.4 mg/L. Air generally is delivered through fine-bubble diffusers, because the air-bubble diameter directly affects TF/SC process performance. Low SVI values were observed in full-scale TF/SC processes that operated the solids contact basin at an aerobic SRT in the range 1.0 to 1.5 days (Parker and Bratby, 2001). Flocs may be subjected to mechanical shear and oxygen deprivation during transport from the solids contact basin to the flocculator-clarifier. Even mild air-induced turbulence in the solids contact basin can disrupt floc structure. Distressing the structural integrity of the flocs or allowing the biomass to revert to an anaerobic state may be detrimental to TF/SC process performance. Therefore, effective biomass management is an important characteristic of well-operating TF/SC processes. A long distance between the solids contact basin and clarifiers may require aerated channels or other process features to promote the maintenance of aerobic flocs. Additional flocculation opportunity is desired and typically is provided with a flocculating clarifier center well. The rapid return of biomass to the solids contact basin also is important to prevent the recurrence of anaerobic biomass. Flocculator-clarifier unit process design has been described by Parker et al. (1996). These units have special features, including flocculating center wells, weir placement, increased sidewater depth, and provision for sludge inventory management. Wahlberg et al. (1994) presented data suggesting that a 20-minute detention time (at average dry-weather flow, with an additional allowance for 50% return sludge flow) in the flocculation well promoted 92% of the obtainable degree of floc formation. Typically, the flocculation center well has a diameter in the range 32 to 35% of the clarifier diameter. The desired design and operational objective is to maintain a minimum sludge blanket thickness (e.g., 0.15-m thickness or less) during normal operating conditions. During a peak wetweather flow, the biomass inventory is transferred from the solids contact basin to the clarifier by the surging flow. The biomass accumulates in the clarifier as a rising
161
162
Biofilm Reactors
sludge blanket. Over time, return sludge pumps convey the accumulated biomass to the solids contact basin. Flocculator clarifiers typically are deeper than conventional units. The sidewater depth generally is in the range 5.5 to 6.0 m. The extra volume exists to accommodate the biomass inventory transferred during wet-weather flow events (Parker et al., 1996). The process designer should note that a scraping-sludgewithdrawal mechanism promotes prolonged biomass retention in the clarifier sludge blanket. Thus, an increased potential exists for the return of anaerobic biomass and elevated suspended solids remaining in effluent stream.
7.7.3 Roughing Filter/Activated Sludge A common method of upgrading existing activated sludge plants is to install a roughing trickling filter before the activated sludge basin. This mode of operation is called the roughing filter/activated sludge (RF/AS) process. The roughing filter is a highly loaded trickling filter that uses 10 to 40% of the media volume required, if treatment has been accomplished through the use of the trickling filter process alone. The aeration basin HRT typically is 30 to 50% of that required with the activated sludge process alone. Although the terms trickling filter/activated sludge (TF/AS) and RF/AS are used interchangeably by designers, the term RF/AS will be used in this discussion. The TF/SC and RF/AS processes have the same process schematic. However, with RF/AS, a smaller trickling filter is used primarily to reduce the organic loading applied to the activated sludge process. Therefore, the suspended growth is responsible for a majority of BOD5 removal.
7.7.4 Biofilter/Activated Sludge The BF/AS process is similar to that of RF/AS, except that RAS is recycled over the trickling filter in a similar fashion as the ABF process. Incorporating RAS recycle over the trickling filter sometimes has reduced sludge bulking from filamentous bacteria, especially with food-processing wastes. Although it sometimes has improved sludge settleability, there is no evidence that sludge recycle improves the oxygen-transfer capability of the biofilter.
7.7.5 Trickling Filter/Activated Sludge The TF/AS process is designed at high organic loads similar to RF/AS or BF/AS. However, the TF/AS process may have an intermediate clarifier between the trickling filter and SGR. The intermediate clarifier removes solids produced in the trickling filter before partially treated wastewater enters the SGR. The reduced oxygen demand afforded by intermediate clarification typically is considered less significant
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
than the savings in capital and operating costs gained by eliminating intermediate clarification. Therefore, most designers prefer to use the RF/AS or TF/SC processes rather than the TF/AS process.
8.0 REFERENCES Albertson, O. E. (1995) Excess Biofilm Control by Distributor-Speed Modulation. J. Environ. Eng. (Reston, Virginia), 121 (4), 330–336. Albertson, O. E. (1989a) Slow Down That Trickling Filter! Water Environ. Technol., 6 (1), 15–20. Albertson, O. E. (1989b) Slow Motion Trickling Filters Gain Momentum! Water Environ. Technol., 6 (8), 28–29. Albertson, O. E.; Davies, G. (1984) Analysis of Process Factors Controlling Performance Plastic Bio-media. Proceedings of the 57th Annual Water Environment Federation Technical Exposition and Conference, New Orleans, Louisiana, Sept 3–Oct. 5; Water Environment Federation: Alexandria, Virginia. Albertson, O. E.; Eckenfelder, W. (1984) Analysis of Process Factors Affecting Plastic Media Trickling Filter Performance. Proceedings of the Second International Conference on Fixed Film Biological Processes, Washington, D.C. Albertson, O. E.; Okey, R. (1988) Design Procedure for Tertiary Nitrification. Surfpac, Inc.: West Chester, Pennsylvania. Andersson, B.; Aspregren, H.; Parker, D. S.; Lutz, M. (1994) High Rate Nitrifying Trickling Filters. Water Sci. Technol., 29 (10–11), 47–52. Arthur, J. W.; West, C. W.; Allen, K. N.; Hedtke, S. F. (1987) Seasonal Toxicity of Ammonia to Five Fish and Nine Invertebrate Species. Bull. Environ. Contam. Toxicol., 38, 324–331. Aryan, A. F.; Johnson, S. H. (1987) Discussion of: A Comparison of Trickling Filter Media. J. Water Pollut. Control Fed., 59, 915. Aspegren, H. (1992) Nitrifying Trickling Filters, A Pilot Study of Malmö, Sweden. Malmö Water and Sewage Works: Malmö, Sweden. ATV (Abwassertechnische Vereinigung) (1983) German ATV Regulations– A135. Grundsätze für die Bemessung von einstufigen Tropfkörpern und Scheibentauchkörpern mit Anschluwerter über 500 Einwohnergleichwerten. D-5205, St. Augustine, Germany (in German).
163
164
Biofilm Reactors
Baier, R. E. (1973) Applied Chemistry at Protein Interfaces. Adv. Chem. Ser. Amer. Chem. Soc., 145, 1. Baxter and Woodman Environmental Engineers (1973) Nitrification in Wastewater Treatment: Report of the Pilot Study. Prepared for the Sanitary District of Bloom Township, Illinois. Benzie, W. J.; Larkin, H. O.; Moore, A. F. (1963) Effects of Climactic and Loading Factors on Trickling Filter Performance. J. Water Pollut. Control Fed., 35, 445–455. Biesterfeld, S.; Dane, M.; Dingeman, R.; Freeman, D.; Heppler, P.; Keilbach, K.; Oram, E.; Paterniti, D.; Wadas, D.; Lutz, M. (2005) Optimizing the TF/ SC Process for Nitrification. Proceedings of the 78th Annual Water Environment Federation Technical Exposition and Conference, Washington, D.C., Oct 9–Nov 2; Water Environment Federation: Alexandria, Virginia. Biesterfeld, S.; Figueroa, L. (2002) Nitrifying Biofilm Development with Time: Activity Versus Phylogenetic Composition. Water Environ. Res., 74, 470–479. Boller, M.; Gujer, W. (1986) Nitrification in Tertiary Trickling Filters Followed by Deep Filters. Water Res., 20, 1363–1373. Boller, M.; Gujer, W.; Nyhuis, G. (1990) Tertiary Rotating Biological Contactors for Nitrification. Water Sci. Technol., 22 (1–2), 89–100. Boltz, J. P.; Daigger, G. T. (2010) Uncertainty in Bulk-Liquid Hydrodynamics Creates Uncertainties in Biofilm Reactor Design. Water Sci. Technol., 61 (2), 307–316. Boltz, J. P.; La Motta, E. J. (2007) The Kinetics of Particulate Organic Matter Removal as a Response to Bioflocculation in Aerobic Biofilm Reactors. Water Environ. Res., 79, 725–735. Boltz, J. P.; La Motta, E. J.; Madrigal, J. A. (2006) The Role of Bioflocculation on Suspended Solids and Particulate COD Removal in the Trickling Filter Process. J. Environ. Eng. (Reston, Virginia), 132 (5), 506–513. Bratby, J. R.; Fox, B.; Parker, D. S.; Fisher, R.; Jacobs, T. (1999) Using Process Simulation Models to Rate Plant Capacity. Proceedings of the 72nd Annual Water Environment Federation Technical Exposition and Conference, New Orleans, Louisiana, Oct 9–13; Water Environment Federation: Alexandria, Virginia.
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
Bruce, A. M.; Merkens, J. C. (1973) Further Studies of Partial Treatment of Sewage by High-Rate Biological Filtration. Water Pollut. Control, 5, 499–527. Bruce, A. M.; Merkens, J. C. (1970) Recent Studies of High Rate Biological Filtration. Water Pollut. Control, 69, 113–148. Bryan, E. H. (1955) Molded Polystyrene Media for Trickling Filters. Proceedings of the 10th Purdue Industrial Waste Conference, West Lafayette, Indiana, May 9–11; Purdue University: West Lafayette, Indiana, 164–172. Bryan, E. H. (1962) Two-Stage Biological Treatment: Industrial Experience. Proceedings of the 11th South Municipal Industrial Waste Conference; University of North Carolina: Chapel Hill, North Carolina, 136. Bryan, E. H.; Moeller, D. H. (1960) Aerobic Biological Oxidation Using Dowpac. Proceedings of the Conference on Biological Waste Treatment; Manhattan College: Riverdale, New York. Characklis, W. G.; Marshall, K. C. (1990) Biofilms; Wiley and Sons: New York. Chartered Institution of Water and Environmental Management (1988) Unit Processes Biological—Manuals of British Practice in Water Pollution Control. Chartered Institution of Water and Environmental Management: London, United Kingdom. Crine, M.; Schlitz, M.; Vandevenne, L. (1990) Evaluation of the Performances of Random Plastic Media in Aerobic Trickling Filters. Water Sci. Technol., 22 (1/2), 227–238. Curds, C. R.; Hawkes, H. A. (1975) Ecological Aspects of Used-Water Treatment, Vol. I; Academic Press: London, United Kingdom. Daigger, G. T.; Heinemann, T. A.; Land, G.; Watson, R. S. (1994) Practical Experience with Combined Carbon Oxidation and Nitrification in Plastic Media Trickling Filters. Water Sci. Technol., 29 (10–11), 189–196. Daigger, G. T.; Norton, L. E.; Watson, R. S.; Crawford, D.; Sieger, R. B. (1993) Process and Kinetic Analysis of Nitrification in Coupled Trickling Filter Activated Sludge Processes. Water Environ. Res., 65, 750–758. Drury, D. D.; Carmona, J.; Delgadillo, A. (1986) Evaluation of High Density Cross Flow Media for Rehabilitating and Existing Trickling Filter. J. Water Pollut. Control Fed., 58, 364–366.
165
166
Biofilm Reactors
Duddles, G. A.; Richardson, S. E.; Barth, E. F. (1974) Plastic Medium Trickling Filters for Biological Nitrogen Control. J. Water Pollut. Control Fed., 46, 937–946. Eckenfelder, W. W. (1961) Trickling Filter Design and Performance. ASCE J. Sanit. Eng. Div., 87, 33–45. Eckenfelder, W. W.; Barnhart, E. L. (1963) Performance of a High Rate Trickling Filter Using Selected Materials. J. Water Pollut. Control Fed., 35, 1535–1551. Everett, J. W., et al. (1995) Slowing Down a Snail’s Pace. Oper. Forum, 20–22. Galler, W. S.; Gotaas, H. G. (1964) Analysis of Biological Filter Variables. ASCE J. Sanit. Eng. Div., 90 (6), 59–79. Germain, J. E. (1966) Economical Treatment of Domestic Waste by Plastic Medium Trickling Filters. J. Water Pollut. Control Fed., 38, 192–203. Grady, L. E.; Daigger, G. T.; Lim, H. (1999) Biological Wastewater Treatment, 2nd ed.; Marcel Dekker: New York. Gray, R.; Ritland, G.; Chan, R.; Jenkins, D. (2000) Escargot…Going…Gone, A Nevada Facility Controls Snails with Centrate to Meet Stringent Total Nitrogen Limits. Water Environ. Technol., 12 (5), 80–83. Gujer, W.; Boller, M. (1986) Design of a Nitrifying Trickling Filter Based on Theoretical Concepts. Water Res., 20, 1353–1362. Gujer, W.; Boller, M. (1984) Operating Experience with Plastic Media Tertiary Trickling Filters for Nitrification. Water Sci. Technol., 16, 201–213. Gullicks, H. A.; Cleasby, J. L. (1990) Cold-Climate Nitrifying Biofilters: Design and Operation Considerations. J. Water Pollut. Control Fed., 62, 50–57. Gullicks, H. A.; Cleasby, J. L. (1986) Design of Trickling Filter Nitrification Tower. J. Water Pollut. Control Fed., 58, 60–67. Harrison, J. R. (2007) Personal communication. Harrison, J. R.; Daigger, G. T. (1987) A Comparison of Trickling Filter Media. J. Water Pollut. Control Fed., 59, 679–685. Harrison, J. R.; Daigger, G. T.; Filbert, J. W. (1984) A Survey of Combined Trickling Filter and Activated Sludge Processes. J. Water Pollut. Control Fed., 56, 1073–1079.
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
Harrison, J. R.; Timpany, P. L. (1988) Design Considerations with the Trickling Filter Solids Contact Process. Proceedings of the Joint Canadian Society of Civil Engineers, ASCE National Conference on Environmental Engineering, Vancouver, British Columbia, July 13–15; American Society of Civil Engineers: Reston, Virginia, 753–762. Hawkes, H. A. (1963) The Ecology of Waste Water Treatment; Pergamon Press: Oxford, United Kingdom. Hawkes, H. A. (1955) Film Accumulation and Grazing Activity in the Sewage Filters at Birmingham. J. Proc. Inst. Sew. Purif., 88–110. Kincannon, D. F.; Stover, E. L. (1982) Design Methodology for Fixed-Film Reactors, RBCs and Trickling Filters. Civ. Eng. Pract. Design Eng., 2, 107–124. Kuenen, J. G.; Jørgensen, B. B.; Revsbech, N. P. (1986) Oxygen Microprofiles of Trickling Filter Biofilms. Water Res., 20 (12), 1589–1598. Lacan, I.; Gray, R.; Ritland, G.; Jenkins, D.; Resh, V.; Chan, R. (2000) The Use of Ammonia to Control Snails in Trickling Filters. Proceedings of the 73rd Annual Water Environment Federation Technical Exposition and Conference, Anaheim, California, Oct 14–18; Water Environment Federation: Alexandria, Virginia. La Motta, E. J.; Jimenez, J. A.; Josse, J. C.; Manrique, A. (2003) The Effect of AirEnduced Velocity Gradient and Dissolved Oxygen on Bioflocculation in the TF/SC Process. Adv. Environ. Res., 7 (2), 441–451. La Motta, E. J.; Jiminez, J. A.; Josse, J. C.; Manrique, A. (2004) The Role of Bioflocculation on COD Removal in the Solids Contact Chamber of the TF/SC Process. J. Environ. Eng. (Reston, Virginia), 130, 726–735. Lee, N. M.; Welander, T. (1994) Influence of Predation on Nitrification in Aerobic Biofilm Processes. Water Sci. Technol., 29 (4), 355–363. Lekhlif, B.; Toye, D.; Marchot, P.; Crine, M. (1994) Interactions Between the Biofilm Growth and the Hydrodynamics in an Aerobic Trickling Filter. Water Sci. Technol., 29, 423–430. Levine, A. D.; Tchobanoglous, G.; Asano, T. (1985) Characterization of the Size Distribution of Contaminants in Wastewater: Treatment and Reuse Implications. J. Water Pollut. Control Fed., 57, 805–816.
167
168
Biofilm Reactors
Levine, A. D.; Tchobanoglous, G.; Asano, T. (1991) Size Distribution of Particulate Contaminants in Wastewater and Their Impact on Treatability. Water Res., 25 (8), 911–922. Lin, H.; Sansalone, J. (2001) Impact of Snail Infestation and Recirculation on Wastewater Treatment Plant Performance During Drought Conditions in the Gulf Coast. Proceedings of the 74th Annual Water Environment Federation Technical Exposition and Conference, Atlanta, Georgia, Oct 13–17; Water Environment Federation: Alexandria, Virginia. Logan, B. E. (1999) Environmental Transport Processes; Wiley & Sons: New York. Logan, B. E.; Hermanowicz, S. W.; Parker, D. S. (1987a) A Fundamental Model for Trickling Filter Process Design. J. Water Pollut. Control Fed., 59, 1029–1042. Logan, B. E.; Hermanowicz, S. W.; Parker, D. S. (1987b) Engineering Implications of a New Trickling Filter Model. J. Water Pollut. Control Fed., 59, 1017–1028. Logan, B. E.; Wagenseller, G. A. (2000) Molecular Size Distributions of Dissolved Organic Matter in Wastewater Transformed by Treatment in a Full-Scale Trickling Filter. Water Environ. Res., 72, 277–281. Lucero, B.; Foess, G.; Middleton, G.; Kucera, W.; Hoff, A. (2002) Snail Control in Trickling Filters. Presented at the Water Environment Association of Texas Annual Conference. Mabbott, J. W. (1982) Structural Engineering of Plastic Media for Wastewater Treatment by Fixed Film Reactors. Proceedings of the First International Conference on Fixed Film Processes, Kings Island, Ohio, April 20–23. Matasci, R. N.; Benedict, A. H.; Parker, D. S. (1986) Trickling Filter/Solids Contact Process: Full-Scale Studies, EPA-600/S2–86-046; U.S. Environmental Protection Agency, Office of Wastewater Management: Washington, D.C. Matasci, R. N.; Clark, D. L.; Heidman, J. A.; Parker, D. S.; Petrik, B.; Richards, D. (1988) Trickling Filter/Solids Contact Performance with Rock Filters at High Organic Loadings. J. Water Pollut. Control Fed., 60, 68–76. Metcalf and Eddy, Inc. (2003) Wastewater Engineering: Treatment and Reuse, Tchobanoglous, G., Burton, F. L., Stensel, H. D. (Eds.); McGraw-Hill: New York. National Research Council (1946) Sewage Treatment at Military Installations. Sew. Works J., 18, 787–1028.
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
Neumayer, A. (2002) Accelerated Gravity Removal of Snail Shells from Trickling Filter Plants. Paper presented at the Annual Conference of the Water Environment Association of Utah, St. George, Utah. Norris, D. P.; Parker, D. S.; Daniels, M. L.; Owens, E. L. (1982) High Quality Trickling Filter Treatment without Tertiary Treatment. J. Water Pollut. Control Fed., 54, 1087–1098. Okey, R. W.; Albertson, O. E. (1989a) Diffusion’s Role in Regulating Rate and Masking Temperature Effects in Fixed-Film Nitrification. Water Environ. Res., 61, 500–509. Okey, R. W.; Albertson, O. E. (1989b) Evidence of Oxygen Limiting Conditions During Tertiary Fixed-Film Nitrification. J. Water Pollut. Control Fed., 61, 510–519. Onda, K.; Takeuchi, H.; Okumoto, Y. (1968) Mass Transfer Coefficients Between Gas and Liquid Phase in Packed Columns. J. Chem. Eng. Jpn., 1, 56–62. Parker, D. S. (1998) Establishing Biofilm System Evaluation Protocols. WERF Workshop: Formulating a Research Program for Debottlenecking, Optimizing, and Rerating Existing Wastewater Treatment Plants. Proceedings of the 71st Annual Water Environment Federation Technical Exposition and Conference, Orlando, Florida, Oct 3–7; Water Environment Federation: Alexandria, Virginia. Parker, D. S. (1999) Trickling Filter Mythology. J. Environ. Eng. (Reston, Virginia), 125 (7), 618–625. Parker, D. S.; Bratby, J. R. (2001) Review of Two Decades of Experience with TF/ SC Process. J. Environ. Eng. (Reston, Virginia), 127 (5), 380–387. Parker, D. S.; Butler, R.; Finger, R.; Fisher, R.; Fox, W.; Kido, W.; Merill, S.; Newman, G.; Slapper, J.; Wahlberg, E. (1996) Design and Operations Experience with Flocculator-Clarifiers in Large Plants. Water Sci. Technol., 33 (12), 163–170. Parker, D. S.; Jacobs, T.; Bower, E.; Stowe, D. W.; Farmer, G. (1997) Maximizing Trickling Filter Nitrification Through Biofilm Control: Research Review and Full Scale Application. Water Sci. Technol., 36, 255–262. Parker, D. S.; Lutz, M.; Andersson, B.; Aspegren, H. (1995) Effect of Operating Variables on Nitrification Rates in Trickling Filters. Water Environ. Res., 67, 1111–1118.
169
170
Biofilm Reactors
Parker, D. S.; Lutz, M.; Dahl, R.; Berkkopf, S. (1989) Enhancing Reaction Rates in Nitrifying Trickling Filters Through Biofilm Control. J. Water Pollut. Control Fed., 61, 618–631. Parker, D. S.; Lutz, M. P.; Pratt, A. M. (1990) New Trickling Filter Applications in the USA. Water Sci. Technol., 22 (1/2), 215–226. Parker, D. S.; Merrill, D. T. (1984) Effect of Plastic Media Configuration on Trickling Filter Performance. J. Water Pollut. Control Fed., 56, 955–961. Parker, D. S.; Richards, T. (1986) Nitrification in Trickling Filters. J. Water Pollut. Control Fed., 58, 896–902. Schroeder, E. D.; Tchobanoglous, G. (1976) Mass Transfer Limitations on Trickling Filter Design. J. Water Pollut. Control Fed., 48, 771–775. Schulze, K. L. (1960) Load and Efficiency of Trickling Filters. J. Water Pollut. Control Fed., 32, 245–253. Solbe, J. F.; de, L. G.; Williams, N. V.; Roberts, H. (1967) The Colonization of a Percolating Filter by Invertebrates, and Their Effect on the Settlement of Humus Solids. Water Pollut. Control, 66, 423–448. Stenquist, R. J.; Parker, D. S.; Dosh, T. J. (1974) Carbon Oxidation-Nitrification in Synthetic Media Trickling Filters. J. Water Pollut. Control Fed., 46, 2327–2339. Takács, I.; Newbeggin, M.; Stephenson, J.; Romano, L. (1996) Optimizing the TF/ SC Process for West Windsor Using a Comprehensive Modeling Technique. Proceedings of the 69th Annual Water Environment Federation Technical Exposition and Conference, Dallas, Texas, Oct 5–9; Water Environment Federation: Alexandria, Virginia. Tekippe, T. R.; Hoffman, R. J.; Matheson, R. J.; Pomeroy, B. (2006) A Simple Solution to Big Snail Problems—A Case Study at VSFCD’s Ryder Street Wastewater Treatment Plant. Proceedings of the 79th Annual Water Environment Federation Technical Exposition and Conference, Dallas, Texas, Oct 21–25; Water Environment Federation: Alexandria, Virginia. Thörn, M.; Mattsson, A.; Sorensson, F. (1996) Biofilm Development in a Nitrifying Trickling Filter. Water Sci. Technol., 34 (1/2), 83–89. Trulear, M.; Characklis, W. G. (1982) Dynamics of Biofilm Processes. J. Water Pollut. Control Fed., 54, 1288–1301.
Trickling Filter and Combined Trickling Filter Suspended-Growth Process
U.S. Environmental Protection Agency (1991) Assessment of Single-Stage Trickling Filter Nitrification, EPA-430/09–91-005; U.S. Environmental Protection Agency, Office of Wastewater Management: Washington, D.C. U.S. Environmental Protection Agency (1993) Nitrogen Control Manual, EPA625/R-93–010; U.S. Environmental Protection Agency, Office of Wastewater Management: Washington, D.C. U.S. Environmental Protection Agency (1975) Process Design Manual for Nitrogen Control; U.S. Environmental Protection Agency, Office of Wastewater Management: Washington, D.C. Velz, C. J. (1948) A Basic Law for the Performance of Biological Filters. Sew. Works J., 20, 607–617. Wahlberg, E. J.; Keinath, T. M.; Parker, D. S. (1994) Influence of Activated Sludge Flocculation Time on Secondary Clarification. Water Environ. Res., 66, 779–786. Wall, D.; Frodsham, D.; Robinson, D. (2001) Design of Nitrifying Trickling Filters. Proceedings of the 74th Annual Water Environment Federation Technical Exposition and Conference, Atlanta, Georgia, Oct 13–17; Water Environment Federation: Alexandria, Virginia. Water Environment Federation; American Society of Civil Engineers; Environmental and Water Resources Institute (2009) Design of Municipal Wastewater Treatment Plants, 5th ed., WEF Manual of Practice No. 8, ASCE Manuals and Reports on Engineering Practice No. 76; McGraw-Hill: New York. Welty, J. R.; Wicks, C. E.; Wilson, R. E. (1976) Fundamentals of Momentum, Heat and Mass Transfer, 2nd ed.; Wiley & Sons: New York. Williams, N. V.; Taylor, H. M. (1968) The Effects of Psychoda alternata (Say) (Diptera) and Lumbricillus rivalis (Levinsen) (Enchytraeidae) on the Efficiency of Sewage Treatment in Percolating Filters. Water Res., 2, 139–150.
171
This page intentionally left blank
Chapter 4
Rotating Biological Contactors 1.0 Introduction
174
2.0 Process design considerations
3.6 Predicted Performance versus Full-Scale Data 191
178
3.7 Temperature Correction192
2.1 Media Surface Area
179
2.2 pH and Nutrient Balance
180
4.0 Rotating biological contactor nitrification models 194
2.3 Oxygen Transfer
180
2.4 Flow and Loading Variability
182
2.5 Operating Temperature 183
5.0 Denitrification Application
197
6.0 Physical design features 198 6.1 Physical Layout
198
6.2 Tank Volume
198
6.3 Hydraulics and Flow Control
198
6.4 Media
199
6.5 Drive Systems
200
3.1 Monod Kinetic Model 184
6.6 Covers
201
3.2 Second-Order Model
186
6.7 Biomass Control
201
3.3 Empirical Model
187
7.0 Rotating biological contactor design examples
202
2.6 Solids Production
183
2.7 Toxic and Inhibitory Substances
184
3.0 Rotating biological contactor design methods
184
3.4 Manufacturers’ Design Curves 189 3.5 Comparison of Model Predictions
190 173
7.1 Secondary Treatment Design Example
202
(continued)
174
Biofilm Reactors
7.2 Advanced Secondary Treatment Design Example
203
8.0 Problems and corrective actions
204
8.4 Loping of Air-Drive Systems
206
8.5 High Clarifier Effluent Suspended Solids 207
8.1 Inadequate Treatment Capacity
205
8.2 Excessive First-Stage Loadings
205
9.0 Pilot-plant studies
207
8.3 Excessive Biomass Growth
206
10.0 References
208
8.6 Corrosion of Media Supports
207
1.0 Introduction The rotating biological contactor (RBC) process is a biological process that has been used widely for secondary and advanced secondary wastewater treatment. The process has been used for five-day biochemical oxygen demand (BOD5) removal, nitrification, or combined BOD5 removal and nitrification. As a secondary treatment process, it has been applied widely, where the average effluent limitations of 30 mg/L BOD5 and total suspended solids (TSS) are required, by permit. As an advanced secondary treatment process, it has been used often in conjunction with effluent filtration, where there are limits of ≤10 mg/L BOD5 and TSS and for effluent ammonia-nitrogen (NH3-N) levels as low as 1 mg/L. The RBC process has been used for aerobic pretreatment of industrial process wastewater, and it also has been used in an anoxic mode for denitrification. The RBC process is a form of fixed-film or attached-growth biological treatment. A circular disk of polystyrene or polyvinyl chloride is mounted on a horizontal shaft and partially submerged (typically 40%) in a tank holding the wastewater undergoing treatment. Plastic packing material, in a cylindrical basket or cage mounted on a horizontal shaft, also has been used. The media is slowly (1 to 1.6 rpm) rotated in the direction of the influent flow, to expose the biological film to food and nutrients and to provide necessary oxygen. Excess biological cell mass is “sloughed” from the media and removed from the wastewater forward-flow by clarification. Figure 4.1 provides a graphic representation of the process.
Rotating Biological Contactors
Cover Rotating biological contactor Interstage baffle
Oxygen
Influent Degradation products Food
Sludge
Effluent
Nutrients
Figure 4.1 General representation of RBC process.
A modification of the RBC process is the submerged biological contactor (SBC), in which the RBC is submerged up to 70 to 90%. Advantages may include lower shaft loadings, ability to retrofit the process to existing activated sludge aeration tanks, use of a dual air-header scouring system (which reduces biomass thickness), and ability to use larger-diameter media bundles. The design approach recommended is similar to that recommended for air-driven RBC systems. The SBCs also have been considered for application in denitrification processes where the shaft is mechanically driven and the introduction of air into the bulk liquid is minimized. In general, however, the SBC has seen limited application. Rotating biological contactor units commonly are manufactured in standard units, with a media bundle of approximately 3.5 m (12 ft) in diameter and 7.5 m (25 ft) in length. Standard-density units have a media surface area of approximately 9300 m2 (100 000 sq ft) per shaft, whereas high-density units typically have a media surface area of approximately 13 900 m2 (150 000 sq ft) per shaft. Standard-density units are used for BOD5 removal, where biological growth is relatively thicker, and more open media are necessary to maintain open passageways for wastewater flow throughout the media. High-density units most commonly are used in nitrification applications, where biofilm growths are relatively thin. Some designs will use lower surface area in the initial stages, followed by higher surface-area media. A more recent development
175
176
Biofilm Reactors
is the use of plastic packing material instead of circular discs. The packing material, contained in a cylindrical cage mounted on the shaft, provides a very high specific surface area for biofilm growth. Rotating biological contactor units are covered to prevent algae growth, excessive heat loss in cold weather, and UV deterioration of polyethylene media. Prefabricated fiberglass, Quonset-hut types of covers commonly have been used, although conventional building structures also are used for covering the units. The RBC process typically is configured with several stages arranged in series, with one or more shafts composing each stage and with one or more parallel trains of shaft stages to provide the needed media surface area. Each train typically consists of several shafts installed in a common tank, with baffles installed between shafts to separate the shafts into distinct stages. The number of stages required depends on the degree of treatment desired, with one or two stages provided for roughing applications and six or more stages provided where advanced treatment with nitrification is necessary. Shafts typically are installed perpendicular to the direction of wastewater flow, with baffles for staging. For plants designed to treat relatively small flows, the shafts may be oriented in the direction of wastewater flow, with baffles provided to allow more than one stage per shaft. Figure 4.2 shows the general arrangements typically used for the RBC process. Shaft rotation most typically has been provided by mechanical-drive systems. Air-drive systems using diffused air and an array of cups, fixed to the periphery of the media, which capture some of the diffused air resulting in rotation from the buoyancy effect, also have been used. The mechanical drive system may be considered a constant-speed/variable-torque system, where shaft revolutions per minute are relatively constant, and torque requirements of the drive system vary with biomass growth and other conditions. The air-drive system may be considered a constanttorque/variable-speed system, where, at a given air rate, the torque applied to the shaft is relatively constant, and the shaft revolutions per minute vary with biomass growth and other conditions. The RBC process has a number of potential advantages, including simplicity and the need for minimal operator attention, low energy costs, low overall costs, and rapid recovery from shock loadings. However, there have been numerous examples of RBC process failure that have resulted from the following: • Structural failure of the shaft, media, or media support systems, • Less-than-anticipated treatment performance,
Rotating Biological Contactors
Typical parallel train configuration
Typical secondary treatment
Typical advanced treatment
End flow for small plants
Figure 4.2 Rotating biological contactor process general flow arrangements.
• Excessive development of nuisance organisms, • Development of excessive or uneven biomass growth, • Inadequate performance of air-drive systems for shaft rotation, and • Misapplication of pilot plant data. Primarily, these failures have been attributed to the following: • Misapplication of the process or use of inadequate design criteria; • Original designs for shafts and media support systems that were inadequate; • Inadequate upstream treatment; • Failure to consider the effect of sidestream loadings in the process design; • Lack of a thorough understanding of the long-term performance efficiency and characteristics of the process in full-scale use;
177
178
Biofilm Reactors
• Development of design standards and criteria on the basis of limited data, much of which was developed using small-scale systems; and • General lack of a conservative approach in developing design relationships for the process. Many of the problems that were associated with earlier installations of the RBC process are now better understood, and the process has been used successfully at numerous locations. However, some regulatory agencies have established policies that restrict or prevent the use of the RBC process in their areas of authority. Therefore, the designer should investigate the applicability of the process in the area of the project before considering the RBC process. In addition to the anticipated benefits or advantages of the RBC process, it is essential that the designer consider the limitations of the process, long-term performance of the process that can be expected in full-scale applications, and other practical knowledge that is based on experience with the RBC process during the last 2 decades. As with any process, proper sizing and process design, a conservative and flexible design approach, and careful consideration to the specification of materials and components are necessary, if the process is to be applied successfully.
2.0 Process design considerations Soluble and particulate carbonaceous BOD5 (cBOD5) components of wastewater are reduced in the RBC process, by a combination of oxidation by the biofilm and synthesis into new cell mass. Soluble waste components, nutrients, and oxygen are transferred to the biofilm from the bulk liquid, and degradation products are transferred from the biofilm to the bulk liquid. Particulate waste components are enmeshed by the biofilm and hydrolyzed before degradation can occur. For the overall process to work successfully, the proper environmental and process conditions must be present. Principal RBC process design considerations include the following: • Media surface area, • pH and nutrient balance, • Oxygen transfer, • Flow and loading variability, • Operating temperature, • Excess biomass production, and • Toxic and inhibitory substances.
Rotating Biological Contactors
2.1 Media Surface Area Adequate media surface area is essential to the process, to provide sufficient biofilm to affect treatment and operate at specific substrate use rates (e.g., the mass of BOD5/ unit and time/unit media surface area). The substrate removal rate must be matched by the oxygen-transfer capability of the system. Sufficient media and proper operational controls are necessary to reduce the potential for nuisance organism development and limit excessive biofilm buildup, which could lead to structural damage to the shaft or media. Selecting the media surface area to be provided to meet design objectives is a balance between a conservative assessment of the capability of the process and economics. Because higher specific substrate use rates occur at higher bulk wastewater substrate concentrations, staging the process can provide the same degree of treatment that could be provided by a single-stage system having a larger surface area. A single-stage system would require that the bulk BOD5 concentration be limited to a relatively low value. This would reduce BOD5 removal rates, because, in the lower range of BOD5 values, specific substrate-use rates are related to concentration (first-order kinetics). Therefore, a more economical design can be provided by staging, where the earlier stages are loaded more heavily organically and have relatively high bulk fluid BOD5 concentrations and higher substrate-removal rates. However, care should be taken so that loadings to the first stages are not high enough to cause inadequate oxygen transfer, nuisance organism development, overweight shafts, and associated process problems. Early graphical methods (prepared by RBC suppliers) for determining media surface area requirements for the RBC process typically have yielded surface areas less than those required to meet design requirements for BOD5 removal based on actual long-term plant operating data. However, graphical methods evolved from a minimal database and pilot units, which later proved to be optimistic in the sizing of RBCs. Recently developed models, which are more reliable for defining surface-area requirements for BOD5 removal and nitrification, are presented and discussed later in this chapter. The reader also is referred to Chapter 3 for a discussion of modeling techniques for trickling filters, which also are applicable to the design of the RBC process. In addition, Chapter 11 provides a general understanding of modeling biofilm systems. A lack of adequate consideration of the effect of loadings from recycle streams, such as solids-processing unit operations or filter backwash, have been reported to be factors in unsatisfactory process performance at several plants. However, this is not
179
180
Biofilm Reactors
a concern that is particular to RBC plants, and it is not caused by the RBC process. Therefore, a designer should develop a complete mass balance of the process, so that the effect of recycle sidestreams on influent flow and organic loadings to the RBC process are considered, and their effect on the determination of required media surface area is incorporated to the design.
2.2 pH and Nutrient Balance As with any biological treatment process, a proper pH and nutrient balance must be provided for effective treatment by the RBC process. The optimum pH for bacterial growth has been reported to be 6.5 to 7.5 (Metcalf and Eddy, 1979). Where nitrification is required, optimum performance has been observed at a slightly alkaline pH, with the optimum pH being 7.5 to 8.5 for suspended-growth systems (Sawyer et al., 1973). For RBC systems, nitrification rates have been reported to fall off rapidly, with the pH decreasing from 7.0 to 6.0 (Brenner et al., 1984). Well-acclimated RBC systems, where the pH is maintained in a narrow range, may be able to tolerate pH values somewhat below 7.0. However, with the minimal buffering at this pH, a stable pH is difficult to maintain. For systems required to nitrify, the alkalinity of wastewater is important because of the consumption of alkalinity. The autotrophic organisms responsible for nitrification consume inorganic carbon (alkalinity). The conversion of the base ammonia (NH3) to nitrate (NO3-) releases hydrogen ions (H+), thereby producing an acid (ammonium oxide [NHO3]). Approximately 7 mg of calcium carbonate (CaCO3) alkalinity are required for each milligram of ammonia-nitrogen oxidized. It has been recommended that a residual alkalinity of 50 to 100 mg/L be maintained in the effluent of a nitrifying plant (Envirex, Inc., 1989). This alkalinity level typically produces a pH of 7.0 or higher. Chemical addition may be necessary to wastewater where natural alkalinity is insufficient. As microorganisms providing treatment require nutrients for cell growth, an adequate supply of available nutrients is necessary for proper performance of the process. A minimum mass ratio of 100:5:1 (BOD: nitrogen:phosphorus) typically is used.
2.3 Oxygen Transfer The rate of oxygen transfer must be sufficient to maintain fully aerobic conditions in the RBC process. Organic loadings above the oxygen-transfer capability of the system result in reduced performance, odors, and development of nuisance organisms.
Rotating Biological Contactors
Maximum oxygen-transfer rates of 6.8 to 7.3 g oxygen/m 2·d (1.4 to 1.5 lb/d/1000 sq ft) have been reported (Scheible and Novak, 1980), based on tests conducted with full-scale, mechanical-drive systems. Studies of supplemental aeration applied to mechanical-drive RBCs indicated an oxygen-transfer efficiency of 2 to 2.5% for applied air (Chou, 1978). If it is assumed that the effective oxygen-transfer rate for an air-drive RBC is 2.5%, a 9300-m2 (100 000-sq ft) air-drive unit supplied with 7 m3/min (250 scfm) would have an oxygen-transfer rate of approximately 8.3 g oxygen/m2·d (1.7 lb/d/1000 sq ft). Maximum oxygen-transfer rates from 6.8 to 8.3 g oxygen/m2·d (1.4 to 1.7 lb/d/1000 sq ft) are consistent with the maximum reported ammonia-nitrogen removal rate of approximately l.5 g/m 2·d (0.3 lb/d/1000 sq ft), based on 4.6 kg oxygen/kg NH3-N oxidized. Historically, pilot testing of the RBC process was performed using small-scale units operating at the same media peripheral velocity (approximately 18 m/min [60 ft/min]) as full-scale units. Data on process performance collected on small-diameter units can be misleading because of the higher oxygen-transfer capability of the smaller units compared with full-scale units. Reh et al. (1977) estimated that a 0.5-mdiameter (1.5-ft-diameter) test unit provided an oxygen-transfer rate 1.6 times that of a 3.2-m-diam (10.5-ft-diam) unit that also was tested. Similar scale-up problems also were noted by other researchers (Brenner et al., 1984). For these reasons, data collected on small-scale systems should be used only for treatability considerations and not to establish sizing criteria. Manufacturers of RBC equipment historically have recommended maximum organic loadings to the first stage of RBC systems of approximately 20 g soluble BOD5 [sBOD5]/m2·d (4 lb/d/1000 sq ft) of media. This equates to an organic loading of 39 g BOD5/m2·d (8 lb/d/1000 sq ft) on a total BOD5-basis for a typical domestic wastewater with 50% soluble BOD5/BOD5 in the primary effluent. However, oxygen-transfer capabilities were reported to have been exceeded at first-stage loadings of more than 15 g sBOD5/m2·d (3 lb/d/1000 sq ft) (McCann and Sullivan, 1980). A survey of 23 plants indicated nuisance organism development because of oxygenlimiting conditions for first-stage loadings in excess of approximately 31.2 g BOD5/ m2·d (6.4 lb/d/1000 sq ft) of media (Weston, Inc., 1985). One RBC manufacturer currently recommends maximum first-stage loadings of approximately 12 to 15 g sBOD5/m2·d (2.5 to 3.0 lb/d/1000 sq ft) for unaerated RBC5 (Envirex, Inc., 1989). This rate equates to 24 to 29 g total BOD5/m2·d (5 to 6 lb/d/1000 sq ft), assuming 50% sBOD5/BOD5 (15 g sBOD5/m2·d [3 lb/d/1000 sq ft]). The manufacturer (Envirex, Inc., 1989) indicates that loadings below these levels provide a safety margin against
181
182
Biofilm Reactors
unexpected loads and prevent sulfide formation. Another manufacturer (Lyco, Inc., 1992) recommends maximum first-stage loadings of 12 to 20 g sBOD5/m2·d (2.5 to 4.0 lb/d/1000 sq ft). The designer should consider limiting organic loading to approximately 29 g BOD5/m2·d (6 lb/d/1000 sq ft) (total BOD5-basis) to any RBC stage. This criterion will limit loadings to levels within the oxygen-transfer capability of the system and reduce the potential for growth of nuisance organisms.
2.4 Flow and Loading Variability Typically, higher effluent concentrations during the higher loading periods of the day are counterbalanced by lower effluent values during low-loading periods. However, a high degree of variability in influent flow or organic loading may disrupt the RBC process. Fixed-film processes, in general, are more susceptible to breakthrough of substrate, as a result of high peak loadings, than are suspended-growth processes. Loadings can increase to the point where breakthrough from the RBC process occurs. At this point, the substrate loading per unit surface area exceeds the substrate removal rate per unit surface area. This potentially could occur as a result of diurnal variations, in which case, it may be more cost-effective to provide flow equalization tanks for load equalization rather than provide additional RBC units. Another potential solution is to store peak day loads for feeding into the process at night, when the influent loads are minimized. It has been recommended (Envirex, Inc., 1989) that flow equalization is incorporated to the design if peak-to-average flow ratios exceed 2.5. The designer also should be aware of variability in organic loadings, including the effect of recycle loads from solids-processing unit operations. Particular attention should be paid to the sBOD concentration in the recycle from dewatering operations. Providing flow equalization may compensate for both flow and loading variability and eliminate the requirement for additional RBC tankage and media. This is especially true if stringent effluent limitations must be met. In the absence of equalization, a high variation in hydraulic or organic loading to the process would need to be addressed by providing additional RBC media and tankage. In addition to daily variations, the designer should consider peak daily loadings, which may result from industrial operations or other variable conditions. Because effluent limitations must be achieved during peak-loading periods and not just under average conditions, appropriate safety or peaking factors should be incorporated to the design. As with any process, the degree of safety factor incorporated to the design
Rotating Biological Contactors
also is influenced by the details of the discharge permit (instantaneous limit, monthly average, annual waste load allocation, etc.).
2.5 Operating Temperature Rates for the removal of BOD5 and nitrification are reduced by cold wastewater temperatures in RBC systems. It is important that the designer carefully review long-term data on wastewater temperatures and select a design temperature representative of critical cold-weather operating periods. For situations in which effluent limitations vary seasonally, each seasonal condition should be checked to determine which period is critical for design purposes. Biochemical oxygen demand removal and nitrification rates typically are reported by RBC equipment manufacturers as being relatively constant above 13°C (55°F) and declining significantly below this temperature (Envirex, Inc., 1989; Lyco, Inc., 1992; Walker Process, Inc., 1992). Relationships developed to adjust media-sizing criteria for reduced temperature operation are presented later in this chapter.
2.6 Solids Production Excess solids production must be estimated to size the solids-handling facilities of the plant. Solids production in the RBC process is a function of the synthesis of new cell mass, cell mass decay caused by endogenous respiration, inert solids present in the wastewater, and solids loss from the system caused by TSS in the clarified effluent. In general, solids production from the RBC process can be expected to be similar to other fixed-film processes. One manufacturer (Envirex, Inc., 1989) reports that waste solids production, based on clarifier underflow, ranges from approximately 0.4 to 0.6 kg/kg total BOD5 removed by the process. Lower values represent lightly loaded systems with higher endogenous oxidation of cell mass, and higher values represent more highly loaded systems. Net solids yields typically will range from 0.5 to 0.8 kg/ kg BOD5 removed from the process. The designer should use a conservative approach to solids production estimates, to account for periods of high biomass release from media and cold-temperature operation, where endogenous respiration will be lower. Typical secondary sludge concentrations for the RBC process are reported to be 2.5 to 3% (Envirex, Inc., 1989), with thickening in a continuous, low-volume solids withdrawal clarification system. Envirex, Inc. (1989) also reports concentrations of 4 to 5% achievable by gravity thickening of the RBC secondary sludge or co-thickening with primary sludge in primary clarification. As with other aerobic biological wastewater treatment processes, solids volatility can be expected to range from 80 to 95%.
183
184
Biofilm Reactors
It generally is good practice to use clarifiers with conventional mechanical solidsremoval mechanisms with the RBC process. Spiral blade sludge collector mechanisms also should be considered. Siphon-type clarifiers typically are not required and will unnecessarily dilute settled solids. Thickening of RBC solids in the clarifier can lead to performance problems. Because the quantity of solids to be removed is relatively low and thicker, uptake pipes or openings are prone to plugging.
2.7 Toxic and Inhibitory Substances Toxic or inhibitory substances, if present in sufficient concentration in plant influent, will have a negative effect on wastewater treatment. In addition, excessive quantities of such substances may have a deleterious effect on solids management and effluent quality because of pass-through. The designer should review current technical literature for information on such substances if they are suspected of being present in concentrations that are deleterious to biological systems.
3.0 Rotating biological contactor design methods Numerous predictive models and equations have been proposed for estimating the removal of BOD5 in RBC systems. Several of these proposed relationships are described in this section. Actual plant performance data also are compared with the predictions of one model and with design curves published by two RBC manufacturers. Some models and manufacturers’ design approaches are based on sBOD 5, and others are based on total BOD5. For a consistent presentation, all models and design approaches are presented graphically on a total BOD5-basis, assuming that sBOD5 of primary effluent makes up 50% of the total BOD5 for both RBC influent and settled effluent.
3.1 Monod Kinetic Model As part of a study funded by the U.S. Environmental Protection Agency (Washington, D.C.) (U.S. EPA) (Weston, Inc., 1985), a design approach was presented based on Monod growth kinetics, as described by Clark et al. (1978). Using a mass-balance approach, assuming steady-state conditions, and making other simplifying assumptions, the following relationship was obtained:
R = (Fi/Ai)(So – Si) = PiSil(Ki + Si)
(4.1)
Rotating Biological Contactors
Where R = substrate removed per unit media surface area per unit time, FI = wastewater flowrate to stage i (gpd), Ai = area of stage i (sq ft), So = influent sBOD5 to stage i (mg/L), Si = effluent sBOD5 from stage i (mg/L), Pi = area capacity constant for stage i (gpd/sq ft-mg/L), and Ki = half-velocity constant for stage i (mg/L). Based on an analysis of interstage sBOD5 data from 11 RBC facilities, values for the maximum removal rate, P, and the half-velocity constant, K, were determined by plotting the data in the linearized form of eq 4.1, as follows: [1/R = (K/PS + 1/P)]. The majority of the facilities were air-driven, and none of the facilities were considered organically overloaded (first-stage total BOD5 loadings were below 31 g BOD5/m2·d [6.4 lb/d/1000 sq ft]). The P and K values were determined for stages 1 through 4, as follows:
(1) Stage 1—P1 = 1000 gpd/sq ft-mg/L and K1 = 161 mg/L (2) Stage 2—P2 = 667 gpd/sq ft-mg/L and K2 = 139 mg/L (3) Stage 3—Ps = 400 gpd/sq ft-mg/L and K3 = 82 mg/L (4) Stage 4—P4 = 100 gpd/sq ft-mg/L and K4 = 25 mg/L.
Using the above coefficients, eq 4.1 can be used to solve for the Si value exiting a given stage, as follows: (Stage 1)
Si =
(Stage 2)
(Stage 3)
{[ HL1 (So − K1 )] − P1 } + {[ HL2 (So − K 2 ) − P2 ]2 + [4( HL3 )2 (K 3 × So )]}0.5 2( HL1 )
(4.2)
where HL1, HL2, HL3 = hydraulic loading rate for stage 1, etc. (m3/m2∙d [gpd/sq ft]). In using the model for design purposes, information must be available, or assumptions must be made, for the ratio of soluble to total BOD5. The work presented in the U.S. EPA study (Weston, Inc., 1985) assumed a sBOD5 fraction of 0.5 for both the RBC influent and settled effluent, which is a typical value for domestic wastewater undergoing RBC treatment. The U.S. EPA study (Weston, Inc., 1985) reported that the model was typically conservative (predicted lower organic removal than observed), with the closest correlation for RBC influent values of approximately 100 mg/L BOD5 or less. The study was reported as being a “first step in collecting input data, which should be used to test the model over a variety of flows and loadings.”
185
Biofilm Reactors
100 Roatating biological contactor influent total BOD5
90
BOD5 removal, %
186
80 75
70
100
125
150
50 60 50 40 0.5
1.0
1.5
2.0
2.5
3.0
3.5
Organic loading, lb BOD5/d/1000 sq ft
Figure 4.3 Clark RBC predictive model, Monod kinetics, BOD5 removal: (1) values are total BOD5; (2) 50% sBOD5 assumed; (3) >13°C (>55°F) temperature; (4) three stages, with 50% of media area in the first stage; and (5) standard-density media (lb/d/1000 sq ft × 4.882 = g/m2·d).
Figure 4.3 presents a graph of solutions of the Clark model for various RBC influent concentrations, as a function of organic loading rate for the assumptions noted. Soluble BOD5 is assumed to be 50% of total BOD5 in the development of this figure.
3.2 Second-Order Model A second-order kinetic model was developed (Opatken, 1980) based on an analysis of interstage data from two full-scale facilities. Predictions of the model were compared with data from nine other full-scale plants, and there was general agreement (Brenner et al., 1984). An equation was developed based on the Levenspiel equation (Levenspiel, 1972), having the following form:
Cn =
−1 + [1 + 4kt(Cn− 1 )]0.5 2kt
(4.3)
Rotating Biological Contactors
100
Rotating biological contactor influent BOD5
BOD5 removal, %
90 80
150 125
100
70
75 60 50
50
40 30 0.5
1.0
1.5
2.0
2.5
3.0
3.5
Organic loading, lb BOD5/d/1000 sq ft
Figure 4.4 Opatken RBC predictive model, second-order kinetics, BOD5 removal: (1) values are total BOD5; (2) >13°C (>55°F) temperature; (3) 50% sBOD5 assumed; (4) three stages, with 50% of media area in the first stage; and (5) standard-density media (lb/d/1000 sq ft × 4.882 = g/m2·d). Where Cn = sBOD5 effluent from stage n (mg/L); k = reaction constant (L/mg·h); and t = average hydraulic retention time (HRT) in stage n (hours). A k rate of 0.083 L/mg·h was determined to be appropriate for municipal wastewater, and a tank volume/media area relationship of 4.9 L/m2 (0.12 gal/sq ft) of media was used to determine HRTs. Figure 4.4 is a graph of solutions for Opatken’s model (1980) for various influent BOD5 concentrations and the assumptions indicated as a function of organic loading. Again, 50% sBOD5 was assumed for both RBC influent and effluent.
3.3 Empirical Model Because the RBC process is an attached-growth process similar to the aerobic biotower and trickling filter processes, mathematical relationships developed for those processes can be used to predict the performance of RBC systems. Benjes (1977) presented an empirical relationship to predict the performance of RBCs. The relationship
187
Biofilm Reactors
was based on the Velz equation (1948) (see Chapter 3) and Schulze (1960), as applied to trickling filters and biotowers. The relationship predicts the fraction of influent BOD5 remaining in the effluent from the process, as a function of media volume and hydraulic loading, as follows: 0.5 Se = e − k (V /Q ) Si
(4.4)
Where Se = effluent total BOD5 (mg/L), Si = influent total BOD5 (mg/L), e = the natural number 2.7183, V = media volume (m3 [cu ft]), Q = average flowrate (m3/m2∙d [gpm]), and k = reaction constant, 0.30.
To establish the reaction constant, Benjes (1977) reviewed operating data from a number of plants. Figure 4.5 is a graph of solutions to the Benjes model for various influent concentrations, for the assumptions shown, as a function of organic loading rate. 95 Rotating biological contactor influent total BOD5
90 85 BOD5 removal, %
188
80 75
150
70
125 100
65
75
60 50
55 50 45 0.5
1.0
1.5
2.0
2.5
3.0
3.5
Organic loading, lb BOD5/d/1000 sq ft
Figure 4.5 Benjes RBC predictive model, BOD5 removal: (1) values are total BOD5; (2) >13°C (>55°F) temperature; and (3) standard-density media (lb/d/1000 sq ft × 4.882 = g/m2·d).
Rotating Biological Contactors
3.4 Manufacturers’ Design Curves Manufacturers of RBC equipment use design relationships that were developed from experimental and full-scale studies. Envirex, Inc. (1989) uses a design approach based on a family of curves to predict effluent BOD5 as a function of hydraulic loading rate and influent sBOD5. Slightly higher performance is predicted for air-drive units compared with mechanical-drive units. Design curves were generated from an experimentally developed relationship between effluent sBOD5 and organic loading (kgsBOD5/m2·d) of the media. Figure 4.6 shows these design relationships, assuming 50% sBOD5 and the other assumptions shown. Figure 4.6 also shows the relationship recommended by Envirex, Inc. (Waukesha, Wisconsin), which applies to the effluent from upstream biological treatment processes and relatively low RBC influent BOD5 (<100 mg/L). Figure 4.6 also shows the design relationships used by Lyco, Inc. (Marlboro, New Jersey), another RBC manufacturer. Lyco, Inc., uses total BOD5 loading as the basis for its design methodology. A third manufacturer, Walker Process, Inc., does not publish design curves and relies on a computerized design technique (Walker Process, Inc., 1992). In addition to the general application of their design procedures to establish media surface-area requirements, manufacturers use other factors, including maximum 50
Effluent total BOD5, mg/L
45 Mechanical drive
40 35
Air drive
30 25 20 15 10
2.0
2.5
3.0 4.0 3.5 4.5 Organic loading, lb BOD5/d/1000 sq ft
5.0
5.5
Figure 4.6 Manufacturers’ RBC design basis, BOD5 removal: (1) values are total BOD5; (2) >13°C (>55°F) temperature; and (3) 50% sBOD5 assumed (Envirex, Inc., 1989) (lb/d/1000 sq ft × 4.882 = g/m2·d).
189
190
Biofilm Reactors
organic loadings to individual stages of the system, temperature corrections for cold-weather operation, wastewater characteristics, and other site-specific information. In some cases, site-specific factors dictate the application of safety factors in determining media area requirements (Envirex, Inc., 1992).
3.5 Comparison of Model Predictions With respect to predictive relationships presented in the preceding sections, a comparison can be made of the organic loading that would result in a given level of treatment for each of the relationships. Table 4.1 shows this comparison for typical domestic wastewater of 125 mg/L total BOD5 in the primary effluent, 50% of which is soluble, and for two different levels of treatment—76% total BOD5 removal to achieve secondary treatment and 90% total BOD5 removal. As indicated in Table 4.1, there is a wide range in predicted organic loading rates applicable to the two treatment levels, as predicted by the models or design approaches. The Benjes model predicts the largest surface-area requirement in each case and would require approximately 1.9 times the media area for the secondary treatment application and more than 3.0 times the media area for the advanced treatment application than that predicted by the model or design approach that yields the lowest media-area requirement. Therefore, the design engineer should use caution in the selection and application of design models in this situation. Table 4.1 Comparison of organic loadings for models. Loading (kg total BOD5/m2·d [lb/d/sq ft]) 76% removal
90% Removal
Clark model
12.7 (2.6)
6.8 (1.4)
Opatken model
15.1 (3.1)
3.9 (0.8)
Benjes model
11.2 (2.3)
3.4 (0.7)
Envirex, Inc., mechanical drive
19.5 (4.0)
10.7 (2.2)
Envirex, Inc., air drive
21.0 (4.3)
12.2 (2.5)
Envirex, Inc., <100 mg/L influent
13.2 (2.7)
7.3 (1.5)
Predictive model or design approach
Lyco, Inc.
17.6 (3.6)
8.8 (1.8)
Walker Process, Inc.
15.1 (3.1)
8.3 (1.7)
Rotating Biological Contactors
3.6 Predicted Performance versus Full-Scale Data Figure 4.7 compares performance predicted by the manufacturer’s design relationships (Envirex, Inc., 1989; Lyco, Inc., 1992) with data from 16 full-scale plants (Weston, Inc., 1985) and data from 11 additional full-scale plants (Doran, 1994). As indicated, the performance of the 27 full-scale plants was significantly lower than predicted by the manufacturer’s design method (Envirex, Inc., mechanical and air drive and Lyco, Inc.) at a given organic loading rate. The Envirex, Inc., design curve for biological effluent and low influent BOD5 concentrations (<100 mg/L total BOD5) compares more favorably with the plant data, but still would predict greater BOD5 removal than achieved at a given organic loading. Figure 4.8 compares performance predicted by the Benjes relationship with data from the same 27 plants as those in Figure 4.7. Figure 4.8 shows the Benjes solutions for 75, 125, and 175 mg/L RBC influent total BOD5 and the data from the 27 plants shown in subsets of 50 to 100, 100 to 150, and greater than 150 mg/L total BOD5 in full-scale plant influent. As indicated in Figure 4.8, predictions from the Benjes relationship compare well with data from the 27 plants over a wide range of conditions. As shown in Figure 4.8, some of the plant data indicate better performance, and some of the data indicate worse performance, compared with the performance 120 Plant data
Effluent total BOD5 mg/L
100
80
60 Mechanical drive
40
Air drive
20
0
0
1
2
3
4
5
6
7
8
Organic loading, lb BOD5/d/1000 sq ft
Figure 4.7 Equipment manufacturers’ predictions versus full-scale plant data, BOD5 removal (lb/d/1000 sq ft × 4.882 = g/m2·d).
191
Biofilm Reactors
100 90 BOD5 removal, %
192
Rotating biological contactor influent BOD5
80 70
175 60 50 40
125
Data 50–100 mg/L 100–150 mg/L > 150 mg/L 0
1
2
75
3
4
5
6
7
8
Organic loading, lb BOD5/d1000 sq ft
Figure 4.8 Benjes RBC model predictions versus full-scale plant data, BOD5 removal: (1) values are total BOD5; (2) k = 0.30; (3) >13°C (>55°F) temperature; and (3) standard-density media (lb/d/1000 sq ft × 4.882 = g/m2·d). predicted by the Benjes relationship. The Benjes model, with k = 0.3, would appear to indicate expected average performance, but would not be suitable for a conservative design approach, without applying a safety factor. Figure 4.9 shows a family of curves representing k rates from 0.2 to 0.4 superimposed on the same plant data in Figures 4.7 and 4.8. A k of 0.27 would encompass approximately 75% of the data in Figure 4.9 and would be analogous to a safety factor of approximately 25% in media volume compared with the use of a k of 0.30. A k of 0.25 would encompass approximately 85% of the data of Figure 4.9. Larger safety factors may be dictated by more stringent maximum daily or weekly effluent limitations, high peak-to-average organic-loading ratios, and other site-specific factors.
3.7 Temperature Correction Cold wastewater temperatures can be expected to reduce the rates of microbial growth and substrate use. The van’t Hoff-Arrhenius relationship commonly has been applied to biological systems to adjust kinetic constants with temperature.
KT = θ ( Τ − 20) K 20
(4.5)
Rotating Biological Contactors
0.6 0.20
Benjes, Inc., k Plant data
Se /Si
0.5
0.25
0.4
0.30 0.35
0.3
0.40
0.2 0.1 0
0.5
1
1.5
2
2.5
3
3.5
4
Hydraulic loading rate, gpd/sq ft
Figure 4.9 Benjes RBC predictive model, effect of k rate on predicted performance (standard-density media assumed) (Envirex, Inc., 1989) (gpd/sq ft × 40.74 = L/m2·d).
Where KT = reaction rate at temperature, T (°C); K20 = reaction rate at 20°C; and θ = temperature coefficient. Theta values from 1.01 to 1.05 for BOD5 removal have been applied to attachedgrowth biological treatment systems. For the RBC process, it has been reported (Weston, Inc., 1985) that actual full-scale field data are sparse and have not provided adequate verification of the temperature coefficient. Benjes (1977) evaluated data from several full- and pilot-scale plants to determine the effect of temperature on the k rate for eq 4.4. From a typical k of 0.3 at temperatures of more than 13°C, the k was reduced to typical values of approximately 0.2 at 7°C and 0.15 at 5°C. All major manufacturers of RBC equipment (Envirex, Inc., 1989; Lyco, Inc., 1992; Walker Process, Inc., 1992) provide adjustment factors in their design approaches for adjusting media surface area requirements for design temperature, as shown in Table 4.2.
193
194
Biofilm Reactors
Table 4.2 Media surface adjustment factors. Temperature correction factor for BOD5 removal ratios Envirex, Inc.
Lyco, Inc.
Walker Process, Inc.
18 (64)
1.00
1.00
1.00
13 (55)
1.00
1.00
1.00
10 (50)
0.87
0.83
0.87
7 (45)
0.76
0.71
0.73
6 (42)
0.67
0.66
0.65
4 (40)
0.65
0.62
—
(°C [°F])
With the correction factors in Table 4.2, the media surface area determined for 13°C (55°F) is divided by the applicable correction factor to determine the required media surface area at the design temperature. Nitrifying systems are predicted to be more sensitive to cold temperatures than systems designed for BOD5 removal. This is a similar situation to experiences with suspended-growth systems. Cold-temperature solids retention times are more than twice as high as those required at warmer temperatures for effective nitrification, depending on system conditions (U.S. EPA, 1977).
4.0 Rotating biological contactor nitrification models Rotating biological contactor systems have been designed to provide nitrification in combined BOD5 removal and nitrification systems, where sufficient media surface area is provided to accomplish both BOD 5 removal and ammonia oxidation. Less commonly, the RBC process has been used to nitrify effluent from other types of biological treatment processes. The total Kjeldahl nitrogen (TKN) concentration should be used when determining the ammonia concentration, because most of the organic nitrogen will be converted aerobically to ammonia. For typical domestic wastewater, RBC manufacturer design information (Envirex, Inc., 1989; Lyco, Inc., 1992; Walker Process, Inc., 1992) indicates that nitrification begins in the RBC process when the total BOD 5 concentration has been reduced to 30 mg/L or less (15 mg/L sBOD5 or less). Brenner et al. (1984), based
Rotating Biological Contactors
on an analysis of plant data, reported that maximum nitrification rates may not be achieved by the RBC process in some cases until sBOD5 values are reduced to approximately 5 mg/L. A relationship based on Monod kinetics was proposed by Pano et al. (1981), as follows:
Ci Z = kN K n + Ci
(4.6)
Where Z = NH3-N removal rate in RBC stage (g/m2·d [lb/d/1000 sq ft]), kn = maximum NH3-N removal rate (g/m2·d [lb/d/1000 sq ft]), Ci = NH3-N concentration in RBC stage (mg/L), and Kn = NH3-N removal half-saturation constant (mg/L). The values for kn and Kn of 0.478 and 0.4, respectively, were developed from pilotscale data at 15°C (59°F) (Brenner et al., 1984). The design basis used by one RBC manufacturer (Envirex, Inc., 1989) is based on a zero-order ammonia oxidation rate at 13°C (55°F), of 1.5 g/m2·d (0.3 lb/d/1000 sq ft) of media for substrate concentrations of more than 5 mg/L NH3-N, with a first-order ammonia removal rate for substrate concentrations of less than 5 mg/L. Envirex, Inc. uses a family of design curves, as shown in Figure 4.10, to determine the required media surface area for nitrification. Based on an evaluation of full-scale data at elevated temperatures, Brenner et al. (1984) report that the maximum zero-order rate of 1.5 g/m2·d (0.3 lb/d/1000 sq ft) does not increase with increasing temperatures above 13°C (55°F). This agrees with the recommendations of two manufacturers (Envirex, Inc., 1989; Lyco, Inc., 1992) that surface-area adjustments should not be made for temperatures of more than 13°C. It is possible that ammonia removal rates of more than 1.5 g/m 2·d (0.3 lb/d/1000 sq ft) are limited by the oxygen-transfer capabilities of the process. Also, high predation may be a factor in reducing nitrification rates at elevated temperatures. Based on an evaluation of limited data, Brenner et al. (1984) concluded that the average performance of full-scale data evaluated was close to the design basis of one manufacturer (Envirex, Inc.), although the plant data were scattered widely, with some data exhibiting ammonia removal rates substantially less than 1.5 g/m2·d. This suggests that a safety factor is needed for design.
195
Biofilm Reactors
Wastewater temperature > 13 °C (>55 °F) Influent ammonia–nitrogen, mg/L 30
6
Effluent ammonia–nitrogen, mg/L
196
25
22 20 19 18 17
16
15
14 13
5
12
4
11 10
3 2 1 0
0
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
Hydraulic loading, gpd/sq ft
Figure 4.10 Manufacturers’ design basis, nitrification of domestic wastewater (Envirex, Inc., 1989) (gpd/sq ft × 40.74 = L/m2·d).
Lyco, Inc. (1992), recommends that the following specific nitrification rates be used for the indicated ranges of ammonia removal: removal range of NH3-N = 45 to 5, 5 to 3, and 3 to 2 mg/L for removal rates of 1.5, 1.2, and 0.75 g/m2·d, respectively. With the above approach, Lyco, Inc. further recommends that the mass of ammonia (kilograms per day) in each of the ranges be computed; that the required media area (square meters) be computed for each range, by dividing the appropriate mass by the removal rate; and that the required media area for each range be summed to determine the total media surface area requirement for nitrification. This approach is similar to one from Envirex, Inc. (1989), in that a maximum ammonia removal rate of 1.5 g/m2·d is assumed, and the removal rate is assumed to decrease for ammonia concentrations of less than 5 mg/L. In sizing RBC systems for nitrification, it is important to recognize that organic nitrogen present in the process also may be available for nitrification because of its hydrolysis to ammonia during the process. Randtke et al. (1978) determined that soluble organic nitrogen from full-scale activated sludge plants averaged 1.5 mg/L and
Rotating Biological Contactors
that approximately 1 mg/L of this was refractory organic material present in the raw wastewater. The amount of refractory organic nitrogen can vary significantly, if there are industrial contributions to the wastewater. On the basis of their studies, Barth and Bunch (1979) proposed that the following quantity of influent TKN is assumed to be available for nitrification and used as the basis of the RBC sizing: TKNa = TKNt – 1 mg/L – (0.055 BOD5r)
(4.7)
Where TKNa = TKN available for nitrification (mg/L), TKNf = total TKN in RBC influent (mg/L), and BOD5r = BOD5 removed in RBC process (mg/L). This relationship assumes that approximately 1 mg/L of the influent TKN is refractory and not available for nitrification and that 0.055 times the BOD5 removed by the process is used for the synthesis of new cell mass. The remaining TKN (the TKNa value) would be available for nitrification and be used as the basis of the RBC sizing. Brenner et al. (1984) also stressed the importance of considering the TKN content of solids processing recycle streams (digester supernatant, dewatering filtrate, heat processing liquors, etc.) and inclusion of these loadings in the process design. Chapter 3 presents additional information regarding various kinetic models used to design fixed-film systems.
5.0 Denitrification Application Because an SBC is almost entirely submerged, oxygen transfer can be minimized. Thus, an anoxic environment suitable for denitrification can be established. Applications of SBCs for denitrification are limited, but one interesting example is the Wallingford Wastewater Treatment Plant (WWTP) in Connecticut (Bradstreet et al., 2009). The existing 30 000 m 3/d (8.0-mgd) WWTP incorporated a predenitrification system to their existing RBC plant by recycling settled solids from the final clarifiers to a basin with 2.1 hours HRT at a capacity of 25 000 m 3/d (6.5 mgd). Pilot studies confirmed the ability of the process to establish a mixed liquor in the basins. After a period of operation during which the performance was optimized, an average annual effluent total nitrogen concentration of less than 8.0 mg/L was achieved. Efforts to improve performance focused on minimizing the dissolved oxygen recycle to the pre-denitrification zones, providing adequate wastewater carbon for denitrification, and establishing the optimum mixed-liquor suspended
197
198
Biofilm Reactors
solids (MLSS) levels (1800 to 2000 mg/L in winter and 3800 to 4000 mg/L in summer). Higher MLSS levels tend to stress the final clarifiers, because, as is typical with RBC plants, they were not designed for such loadings. A post-denitrification system using SBCs with supplemental carbon addition was planned to decrease the effluent total nitrogen concentration to less than 5.0 mg/L. The design recommendation from the manufacturer was based on a loading of 14.4 g/m3 (0.9 lb NO3/1000 cu ft) safety factor of submerged biological contactor (SBC) media surface area.
6.0 Physical design features 6.1 Physical Layout In planning physical layout, a designer should consider equipment access for maintenance purposes and future plant-expansion requirements. Access to bearings, load cells, drives, air valves, and other equipment requiring routine inspection and maintenance should be provided for safe and convenient operation and maintenance by WWTP staff. The designer should consider the potential need for shaft removal for repair and replacement and access isles between trains for crane access. Tank drains should be provided to facilitate dewatering of tankage for inspection and maintenance. Portable blowers or other provisions for adequate ventilation should be provided for safe entry to any confined space. The future construction of parallel trains or other processes to provide future capacity or enhanced treatment should be considered during design. Adequate space should be reserved on-site for these facilities, as appropriate. “Knockouts” can be provided in channels, division boxes, and so on, to facilitate future plant construction.
6.2 Tank Volume The tank volume to contain the RBCs typically is sized at 4.9 L/m2 (0.12 gal/sq ft) of media for low-density units. Tanks for high-density units have been designed to be of the same size and configuration as for a low-density shaft having the same physical dimensions to simplify layout and for economic construction.
6.3 Hydraulics and Flow Control Flow through the RBC process is by gravity from the process influent to the clarifier effluent. In hydraulic design, the designer should consider providing effective
Rotating Biological Contactors
flow-splitting between parallel units, the ability to isolate process trains or to bypass tanks arranged in series to facilitate maintenance, and the ability to step-feed the first stages of the process to control first-stage organic loading. The ability to provide stepfeeding may be of particular importance to multi-shaft first stages, to allow for more uniform loading to the shafts making up the stage. Flow commonly is split to parallel trains by providing a low headloss influent channel perpendicular to the train flow path and by providing free discharge weirs at the influent end of each train. Aeration of the influent channel often is provided in such designs to reduce the potential for septicity and maintain solids in suspension in low-velocity influent channels. Feed to the influent channel may be best accomplished in a symmetrical fashion, to reduce potential problems with uneven distribution of loading to process trains. Isolation of process trains can be accomplished readily by using gates or stop logs at the influent and effluent ends of the trains. A free discharge on the effluent end and wide low-head influent weirs improve the capability of effective hydraulic isolation for maintenance. This is because a free discharge will prevent the effluent from backing up into an isolated channel (should isolation gates not be installed), and a wide low-head weir will minimize the increase in the water-surface elevation in the RBC trains remaining in service.
6.4 Media Rotating biological contactor units are provided in low-, medium-, and high-density configurations, with low-density units having a media surface area of approximately 118 m2/m3 (36 sq ft/cu ft), and high-density units having a media surface area of 180 m2/m3 (55 sq ft/cu ft). This compares with 100 m 2/m3 (30 sq ft/cu ft) (standard density) and 140 m2/m3 (42 sq ft/cu ft) (high density) for plastic biotower media. Low-density media are used in the first stages of RBC systems designed for BOD5 removal, to reduce potential media clogging problems and overweight problems caused by higher biomass accumulations. High-density media typically are used in the latter stages of systems designed to achieve relatively low BOD5 values and in portions of systems designed for nitrification. Medium-density media are recommended by one manufacturer (Lyco, Inc., 1992) as a transitional media to be installed following the initial stages of the process, where low-density media are used, and preceding high-density media used in low BOD5 loading stages and for nitrification.
199
200
Biofilm Reactors
6.5 Drive Systems Both mechanical- and air-drive systems are available for RBC systems. Mechanicaldrive systems consist of an electric motor, speed reducer, and belt- or chain-drive components separately provided for each shaft. Multistage speed reducers also are used instead of belt or chain drives. Typically, 3.7-kW (5-hp) mechanical drives have been provided for full-size units (media approximately 3.5 m in diameter and 7.5 m in length). Air-drive units involve remote blower facilities delivering air to header systems located under each shaft. Air headers are equipped with coarse-bubble diffusers, and approximately 4.2 to 11.3 m3/min (150 to 400 scfm) of air are provided per standard size shaft, depending on media density, revolutions per minute, wastewater temperature, slime thickness and characteristics, and other conditions. The quantity of air required for air-drive systems is difficult to predict and can vary considerably from shaft to shaft and over time, depending on environmental and loading conditions. Mechanical-drive units have been designed for operation from 1.2 to 1.6 rpm, and air-drive units have been designed for operation from 1.0 to 1.4 rpm. Rotational speeds should be consistent, and an even biomass growth should be maintained, to avoid uneven shaft weight. Unbalanced growth may cause cyclical loadings in mechanical-drive systems and loping (uneven rotation) in air-drive systems. A loping condition often accelerates and, if not corrected, may lead to inadequate treatment and the inability to maintain rotation in the unit. For mechanical-drive systems, materials, and motor designs should be selected that will resist the corrosive effect of a humid operating environment. Rotationalspeed flexibility should be provided by alternative pulley or sprocket ratios or by providing variable-speed drives. Air-drive systems should provide ample reserve air supply to maintain rotational speeds, restart stalled shafts, and provide short-term, relatively high rotational speeds to control excessive or unbalanced biomass growth. Available data indicate that an air rate of 11.3 m3/min (400 scfm) or more per shaft may be needed to maintain 1.2 rpm in a heavily loaded situation (Brenner et al., 1984). Large-capacity air cups (150 mm) typically are provided in the first stages of the process. These air cups provide the capability to exert a greater torque on the shaft and reduce loping problems. Smaller-capacity air cups (100 mm) typically are provided on those stages receiving low BOD5 loadings and those designed for nitrification (Envirex, Inc., 1992). With air-drive systems, manual adjustments to the air rate to a given shaft may affect the air delivered to other units and their rotational speed. This problem has been overcome at some installations, by providing rotational-speed sensors and automatic
Rotating Biological Contactors
adjustment of valve settings to individual shafts to maintain selected revolutions per minute. Such systems also have been designed to provide sensing and alarms for uneven rotation or loping conditions.
6.6 Covers The RBC process requires covering for protection from atmospheric conditions, media deterioration from UV light, and algal growth. Rotating biological contactor systems